Engineering Data Submittal Manual

Size: px
Start display at page:

Download "Engineering Data Submittal Manual"

Transcription

1 REVISION HISTORY REV DESCRIPTION ECN DATE APPROVED A ADD ZS-ZT INFORMATION /3/16 BDL Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS ZS/ZT HORIZONTAL PACKAGED SYSTEMS WATER-TO-AIR HEAT PUMPS G:\Drafting\Drawings\Released-Production\PDF\20D805-01NN REVA Unit Tag Model Number 20D21401NN 20D214-16NN REVISION: B Notes:

2 TABLE OF CONTENTS Introduction General:... 5 Basic Construction:... 5 Fan and Motor Assembly:... 6 Refrigerant Circuit:... 6 Drain Pan:... 6 Electrical:... 7 Control Board System:... 7 Solid State ECM Fan Control Board (included with ECM blower option):... 7 Optional DDC (Direct Digital Controls) Interface System:... 7 Warranty:... 8 DDC Sensors:... 8 Field Installed Options:... 8 Model Nomenclatures: ZS Model Nomenclature... 9 ZT Model Nomenclature... 9 AHRI Performance Data ZT Two Stage, ECM Blower, Braze Plate ZS Single Stage, ECM Blower AHRI Performance Data ZS Single Stage, PSC Blower...11 Typical Ductwork Connection Setup: Optional Filter Rack Kit Installation: Horizontal Unit Suspension Seismic Hanger Bracket Horizontal Unit Suspension Hanger Locations and Dimensions Horizontal Unit Suspension Hanger Locations and Dimensions Unit Dimensional Data: Isometric Views: Service Access Clearances: ZT Unit Electrical Data: ZT ZT Unit Electrical Data: ZT ZS - ECM Unit Electrical Data: ZS - PSC Unit Electrical Data: ECM Fan Performance: PSC Fan Performance: Filter Performance: Glossary of Terms: Sensible Cooling Correction Factors: Heating & Cooling Calculations: Cooling Correction Factors: Heating Correction Factors: Water Flow Selection: Performance Data Tables and Notes: ZT SC/SH Tables... 33

3 ZT Models Performance Tables Model ZT024, 2 Ton, Full Load Performance Data: Model ZT024, 2 Ton, Part Load Performance Data: Model ZT030, 2.5 Ton, Full Load Performance Data: Model ZT030, 2.5 Ton, Part Load Performance Data: Model ZT036, 3 Ton, Full Load Performance Data: Model ZT036, 3 Ton, Part Load Performance Data: Model ZT040, 3.5 Ton, Full Load Performance Data: Model ZT042, 3.5 Ton, Part Load Performance Data: Model ZT048, 4 Ton, Full Load Performance Data: Model ZT048, 4 Ton, Part Load Performance Data: Model ZT060, 5 Ton, Full Load Performance Data: Model ZT060, 5 Ton, Part Load Performance Data: Model ZT072, 6 Ton, Full Load Performance Data: Model ZT072, 6 Ton, Part Load Performance Data: Model ZS006,.5 Ton, w/psc, Full Load Performance Data: ZS Models Performance Tables Model ZS009,.75 Ton, w/psc, Full Load Performance Data: Model ZS012, 1 Ton, w/psc, Full Load Performance Data: Model ZS015, 1.25 Ton, w/psc, Full Load Performance Data: Model ZS017, 1.5 Ton, w/psc, Full Load Performance Data: Model ZS018, 1.5 Ton, w/psc, Full Load Performance Data: Model ZS024, 2 Ton, w/psc, Full Load Performance Data: Model ZS030, 2.5 Ton, w/psc, Full Load Performance Data: Model ZS036, 3 Ton, w/psc, full Load Performance Data: Model ZS042, 3.5 Ton, w/psc, Full Load Performance Data: Model ZS048, 4 Ton, w/psc, Full Load Performance Data: Model ZS060, 5 Ton, w/psc, Full Load Performance Data: Model ZS072, 6 Ton, w/psc, full Load Performance Data: Model ZS015, w/ecm, Full Load Performance Data: Model ZS017, w/ecm, Full Load Performance Data: Model ZS018, 1.5 Ton, w/ecm, Full Load Performance Data: Model ZS024, 2 Ton, w/ecm, Full Load Performance Data: Model ZS030, 2.5 Ton, w/ecm, Full Load Performance Data: Model ZS036, 3 Ton, w/ecm, Full Load Performance Data: Model ZS042, 3.5 Ton, w/ecm, Full Load Performance Data: Model ZS048, 4 Ton, w/ecm, Full Load Performance Data: Model ZS060, 5 Ton, w/ecm, Full Load Performance Data: Model ZS072, 6 Ton, w/ecm, full Load Performance Data:

4 This page Intentionally Left Blank 4

5 Introduction General: Packaged Single and Two-Stage Horizontal ZS/ZT Series Water Source and Geothermal Heat Pumps shall be constructed based on all information to follow. Equipment shall be completely assembled, piped, internally wired, charged with refrigerant, and tested. Units shall be supplied completely factory built capable of operating over an entering water temperature range from 20 to 120 F (-6.7 to 48.9 C) (extended data tables; Heating 25F 90F, cooling 50F 110F) as standard. All equipment listed in this section must be rated and certified in accordance with Air-Conditioning, Heating and Refrigeration Institute/International Standards Organization (AHRI/ISO ). All equipment must be tested, investigated, and determined to comply with the requirements of the standards for Heating and Cooling Equipment UL-1995 for the United States and CAN/CSA-C22.2 NO.236 for Canada, by Intertek Testing Laboratories (ETL). The units shall have AHRI/ ISO and ETL-US-C labels. All units shall be fully quality tested by factory run testing under normal operating conditions as described herein. Quality control system shall automatically perform via computer: helium leak check of both the water and refrigerant circuits, pressure tests, double evacuation and accurately charged system, perform detailed heating and cooling mode run tests, and quality cross check all operational and test conditions to pass/fail criteria. Note: If unit fails on any check, it shall not be allowed to ship. Units without water flow are not acceptable. Basic Construction: Horizontal units shall have one of the following air flow arrangements: Left or Right Return air. The supply air discharge shall be field convertible from a straight through (side) to an end configuration. The heat pumps shall be fabricated from heavy gauge galvanized steel. Cabinet air leakage rating must meet ASHRAE standards. All access panels on the air side of the cabinet must be gasketed to ensure proper seal. Option: Cabinet finish to be painted heavy gauge galvanized steel. This corrosion protection system shall meet the stringent 1000 hour salt spray test per ASTM B117. All units must have a minimum of three access panels for serviceability of compressor compartment. See EDSM manuals for service clearances. All units must have an insulated panel separating the fan compartment from the compressor compartment All interior surfaces shall be lined with 3/8 inch (9.5mm) thick, 3-6 lb/ft3 (24 kg/m3) NBR/PVCbased closed cell, non-porous, non-fibrous Nitrile/ Vinyl, flexible elastomeric foam insulation passing QUV test chamber UV ASTM D4329, D4587 ISO 4892, SAE J2020 resistance, it shall be free of CFCs, HFCs, HCFCs, PBDEs, formaldehyde and fibers. Standard ENGINEERING SPECIFICATIONS: cabinet panel insulation must meet UL-1995 and ASTM E 84/UL 723 Flame 25 / Smoke 50 requirements, air erosion and mold growth limits of UL-181, stringent fungal resistance test per ASTM-C1071 and ASTM G21, and shall meet zero level bacteria growth per ASTM G22. The insulation shall be UL-GREENGUARD certified under the Children and Schools classification and approved by the Factory Mutual Research Corporation. For added protection it shall be protected with an EPA-approved antimicrobial agent. All horizontal units to have field installed discharge duct collar, shipped loose and factory installed return airduct collar (residential model s) or 1 filter rack (commercial model s). An optimal 1-2 deluxe filter rack is also available to purchase separately. Horizontal units shall have field installed (shipped loose) hanger brackets included that screw to the corner post of the heat pump. Each bracket comes with a high density elastomeric anti-vibration pad that the threaded rod will be attached too. 3 of the 4 hanger brackets will be field convertible from the end to the side of the corner post to eliminate any installation, maintenance, and service issues. See IOM for further details. Option: Units shall have a factory installed deluxe galvanized filter rack provided by heat pump manufacturer. Filter removal from either side with access door as part of the bracket. Units shall have a 1 (25.4mm)(MERV 8) or 2 (50.8mm)(MERV 13) thick throwaway type pleated filter option. Option: Units shall have a factory installed 1 or 2 filter rail (open on both sides) provided by heat pump manufacturer. Units shall have a 1 (25.4mm) (MERV 8) or 2 (50.8mm)(MERV 13) thick throwaway type pleated filter option. Cabinets shall have separate holes and knockouts for entrance of line voltage and low voltage control wiring. All factory-installed wiring passing through factory knockouts and openings shall be protected from sheet metal edges at openings by plastic ferrules. Supply and return water connections shall be copper FPT fittings, and shall be securely mounted flush to the cabinet corner post allowing for connection to a flexible hose without the use of a back-up wrench. All water connections and electrical knockouts must be in the compressor compartment corner post as to not interfere with the serviceability of unit. The unit shall be supplied with extended range internal insulation as standard. All internal water lines and the evaporator side refrigeration tubing shall all have closed cell EPDM insulation. The water to refrigerant BPHE or coaxial heat exchanger shall have 8lb. Envelo-Seal rigid closed cell spray foam applied to a minimum of.5 thickness. Option: Multi-Density sound attenuating compressor blanket for additional noise reduction. 5

6 Option: The unit will be supplied with internally factory mounted automatic water flow control valve (on/off). Option: The unit will be supplied with internally mounted source fluid circulating pump for primary/ secondary source piping applications. Option: Insulation package for extended range can be omitted for standard range applications. Fan and Motor Assembly: Blower shall have orifice rings to allow removal of wheel and motor from one side without removing housing. The fan assembly or housing shall be removable without removing the ductwork. Units shall have a direct-drive centrifugal fan with a dynamic balanced wheel. The fan motor shall be a 3-speed PSC ball bearing type motor. The fan motor shall be isolated from the housing by rubber grommets. The motor shall be permanently lubricated and have thermal overload protection. Option: The unit shall have an ECM variable speed blower motor type. The motor will have 3 fan speed selections, a constant fan operation mode, as well as a dehumidification mode. This ECM fan motor incorporates a soft start feature (ECM is standard with two-stage compressor).option: The unit shall have a high static PSC motor, available on certain sizes only. Option: The unit shall have an ECM constant torque variable speed blower motor type. The motor will have 3 fan speed selections. Refrigerant Circuit: All units shall contain R-410A sealed refrigerant circuit including a high efficiency single stage rotary or scroll or two-stage unloading scroll compressor designed for heat pump operation, a thermostatic expansion valve for refrigerant metering, microchannel refrigerant to air heat exchanger, reversing valve, brazed plate refrigerant to water heat exchanger, and safety controls (see controls section). Refrigerant access ports shall be factory installed on high and low pressure refrigerant lines to facilitate field service. Hermetic compressors shall be internally sprung. The compressor shall have a dual level vibration isolation system. The compressor will be mounted on rubber grommets secured to a large heavy gauge compressor mounting plate, which is then mounted to the cabinet base with specially engineered sound-tested elastomeric foam vibration isolation pads for maximized vibration attenuation. Compressor shall have thermal overload protection. Compressor discharge and suction refrigerant lines to have shock loops directly at compressor for additional vibration elimination. Compressor shall be located in an insulated compartment away from air stream to minimize sound transmission. Refrigerant to air heat exchangers (air coil) shall utilize an all aluminium micro-channel construction and be rated to withstand 625 PSIG (4309 kpa) refrigerant working pressure. Refrigerant to water heat exchangers shall be of A-Symetrical brazed plate stainless steel design, rated to withstand 625 PSIG (4309 kpa) working refrigerant pressure and 450 PSIG (3445 kpa) working water pressure, and designed to have a low water pressure drop (max. 10ft.hd.). Refrigerant metering shall be accomplished by thermostatic expansion valve only. Expansion valves shall be dual port balanced types with external equalizer for optimum refrigerant metering. The expansion valves must be bi-directional without the use of check valves. Units shall be designed and tested for operating ranges of entering water temperatures from 20 to 120 F (-6.7 to 48.9 C). Reversing valve shall be four-way solenoid activated refrigerant valve, which shall default to heating mode should the solenoid fail to function. Option: The unit will be supplied with a refrigerant to water coaxial heat exchanger and shall be of copper inner water tube and steel refrigerant outer tube design (water coil), shall have enhanced rifled and knurled inner tube, rated to withstand 625 PSIG (4309 kpa) working refrigerant pressure and 500 PSIG (3445 kpa) working water pressure, and designed to have a low water pressure drop (max. 15ft.hd.). Option: The unit will be supplied with a cupro-nickel coaxial water to refrigerant heat exchanger. Option: The unit shall be supplied with a hot water generator (desuperheater) heat exchanger, which shall be double wall and vented. This option will also include an internal circulating pump. Option: Unit shall include on/off hot gas reheat option. Control of reheat must be accomplished via a humidistat or dehumidistat contact closure. The reheat coil will also be constructed from all aluminium micro-channel design. Option: Unit shall include hot gas bypass to keep the air coil from freezing in low load conditions. Drain Pan: The drain pan shall be constructed of 304 Stainless Steel to inhibit corrosion. This corrosion protection system shall meet the stringent 1000 hour salt spray test per ASTM B117. Drain pan shall be fully insulated. The unit as standard will be supplied with solid-state electronic condensate overflow protection (see controls section). Units shall be furnished with a 3/4 PVC condensate drain connection. The drain pan comes with end drainage. For full drainage of pan unit must be pitched down towards corner with drain (See page 18). 6

7 Electrical: A control box shall be located within the unit compressor compartment and shall contain a 50VA or 75VA transformer, 24 volt activated, 2 or 3 pole compressor contactor, terminal block for thermostat wiring and digital controller for complete unit operation and control. Units shall be nameplated for use with time delay fuses or HACR circuit breakers. Unit controls shall be 24Vac and provide heating or cooling as required by the remote thermostat/sensor. A detachable low voltage thermostat terminal strip with screw terminals to be provided for field wiring. Option: Unit will come with factory installed soft start device to reduce start-up amps by 60% to avoid light flicker where power supply is a concern (only available on certain models). Option: Unit shall come with a factory installed phase monitor for 3-phase equipment to ensure proper phasing of the voltage to protect the compressor from operating backwards. Option: Unit shall have a factory mounted electrical disconnect switch to provide on/off service of the main electrical system to the heat pump. Control Board System: Units shall have a digital control system. The control system microprocessor board shall be specifically designed to protect against building electrical system noise contamination, EMI, and RFI interference. The control system shall interface with a heat pump type 24Vac thermostat. The control system shall have the following features: A. Anti-short cycle time delay on compressor operation (5 minutes). B. Random start on power up mode. C. Low voltage protection. D. High voltage protection. E. Unit shutdown on high or low refrigerant pressures. F. Unit shutdown on low temperature (low source coil temp OR low air coil temp). G. Condensate overflow electronic protection. H. Option to reset unit at thermostat or disconnect (soft or hard reset functions) I. Fault retry logic. The same fault trip has to occur 3 times before a hard lockout. If a fault occurs 3 times within 30 minutes sequentially without thermostat meeting temperature, then lockout requiring manual reset will occur. A soft or hard reset will restart the unit. J. Ability to defeat time delays for servicing (test mode). K. Light emitting diode (LED) on circuit board to indicate high pressure, low pressure, low/high voltage, low water/air temperature, condensate overflow, high discharge gas temperature, faulty temperature sensor(s), and control voltage status. L. The low-pressure switch shall not be monitored for the first 40 seconds after a compressor start command to prevent nuisance safety trips. M. 24Vac output to cycle a motorized water valve or other device with compressor contactor. N. Water coil low temperature sensing selectable for water or anti-freeze. O. Air coil low temperature sensing. P. High discharge gas temperature sensing. Q. Smart desuperheater operation and logic to eliminate any heat transfer from the water tank to the source loop during cooling mode. R. Loss of charge compressor protection logic, which will not allow the unit to try and start when the low pressure switch is open on startup, indicating a loss of charge. S. Optional fluid flow proving switch.this is located in the source inlet water piping. Solid State ECM Fan Control Board (included with ECM blower option): Airflow selection shall be accomplished via dip switch settings on the ECM control board. Actual airflow shall be indicated by the CFM LED with each 100 CFM being represented by one flash of the LED. Airflow shall be automatically maintained (±5%) by the ECM motor regardless of external static pressure up to its maximum output capacity. A dip switch shall allow selection of a special dehumidification mode, which reduces airflow in cooling by 50 CFM/ton to increase the latent capacity of the unit. A terminal shall be provided on the control board to allow an external humidistat to activate dehumidification mode, or the control board can be set to constant dehumidification mode. Optional DDC (Direct Digital Controls) Interface System: Units shall have all the features listed above and the control board will be supplied with a DDC interface board. Available protocols are BACnet MS/TP, Modbus, or Johnson Controls N2. The choice of protocol shall be field selectable/changeable via the use of a simple selector switch. Protocol selection does require additional programming, external hardware or software tools. This will permit all units to be daisy chain connected by a 2-wire twisted pair shielded cable. The following points must be available at a central or remote computer location: A. space temperature B. leaving water temperature C. discharge air temperature D. command of space temperature setpoint E. cooling status F. heating status G. low temperature sensor alarm H. low pressure sensor alarm I. high pressure switch alarm J. condensate overflow alarm K. hi/low voltage alarm L. fan ON/AUTO position of space thermostat as specified above M. unoccupied/occupied command N. cooling command O. heating command P. fan ON/AUTO command Q. fault reset command R. itemized fault code revealing reason for specific shutdown fault (any one of 7) 7

8 Warranty: Enertech shall warranty equipment for a period of 12 months from start up or 18 months from shipping (which ever occurs first). All warranty coverage is parts only, no labor. Option: Extended 4-year compressor warranty covers compressor for a total of 5 years. Option: Extended 4-year refrigeration circuit warranty covers heat exchanger coils, reversing valve, expansion valve and compressor for a total of 5 years. Option: Extended 4-year all internal parts which covers the entire heat pump for a total of 5 years. DDC Sensors: Wall mounted DDC sensor to monitor room temperature and interfaces with optional interface system described above. Several types as described below: Sensor only with no display (LON and MPC). Sensor with override (LON only). Sensor with setpoint adjustment and override (MPC only). Sensor with setpoint adjustment and override, LCD display, status/fault indication (LON and MPC). Field Installed Options: Hose Kits: All units shall be connected with hoses. The hoses shall be 2 feet (61cm) long, rubber; fire rated hoses complete with adapters. Only fire rated hoses will be accepted. Valves: The following valves are available and will be shipped loose: A. Ball valve; bronze material, standard port full flow design, FPT connections. B. Ball valve with memory stop and PT port. C. Y strainer with blowdown valve; bronze material, FPT connections. D. Motorized water valve; slow acting, 24Vac, FPT connections. valve, and ball valve with PT port; return hose having ball valve with PT port. Thermostats: The thermostat shall be an electronic type thermostat as selected below with the described features: A. Multistage Digital Non-Programmable Automatic or Manual Changeover thermostat (24Vac). Thermostat shall be multi-stage (2H/2C), manual or automatic changeover with HEAT-OFF-COOL- AUTO-EM HEAT system settings and fan ON-AUTO settings. Thermostat shall have an LCD display with temperature, set-point(s), mode, and status indication. The temperature indication shall be selectable for ºF or ºC. The thermostat shall provide permanent memory of set-point(s) without batteries. A fault LED shall be provided to indicate specific fault condition(s). B. Multistage Digital Programmable Automatic or Manual Changeover thermostat (24Vac) Thermostat shall be 7 day programmable (with up to 4 set points per day), multi-stage (3H/2C), automatic or manual changeover with HEAT-OFF-COOL-AUTO-EM HEAT system settings and fan ON-AUTO settings. Thermostat shall have a blue backlit dot matrix LCD display with temperature, setpoints, mode, and status indication. The temperature indication shall be selectable for ºF or ºC. Time display shall be selectable for 12 or 24 hour clock. Fault identification shall be provided to simplify troubleshooting by providing specific unit fault at the thermostat with red backlit LCD during unit lockout. The thermostat shall provide permanent memory of setpoints without batteries. Thermostat shall provide heating set-point range limit, cooling set-point range limit, temperature display offset, keypad lockout, dead-band range setting, and inter-stage differential settings. Thermostat shall provide progressive recovery to anticipate time required to bring space temperature to the next programmed event. Thermostat shall provide an installer setup for configuring options and for setup of servicing contractor name and contact information. Thermostat shall allow the use of an accessory remote and/or outdoor temperature sensor. Hose Kit Assemblies: The following assemblies ship with the valves already assembled to the hose described: A. Supply and return hoses having ball valve with PT port. B. Supply hose having ball valve with PT port; return hose having automatic flow regulator valve with PT ports, and ball valve. C. Supply hose having Y strainer with blowdown valve, and ball valve with PT port; return hose having automatic flow regulator with PT ports, and ball valve. D. Supply hose having Y strainer with blowdown 8

9 Model Nomenclatures: ZS Model Nomenclature ENGINEERING SPECIFICATIONS: Brand: G = GeoComfort H = Hydron Module T = TETCO A = GeoExcel 1: Brand Type: Z = Horizontal 2: Type Stage: S = Single Stage - R-410a 3: Stage - Z S 048 Unit Capacity (Nominal MBTUH): 006, 009, 012, 015, 017, 018, 024, 030, 036, 042, 048, 060, 072 Revision: B = Current Revision 4, 5, 6: Unit Capacity 7: Revision Voltage: 1 = 208/230V, 60Hz, 1Ph (Residential) 0 = 208/230V, 60Hz, 1Ph (Commercial) 2 = 208/230V, 60Hz, 3Ph (Commercial) - ( Units Only) 3 = 460V, 60Hz, 3Ph (Commercial) - ( Units Only) 4 = 575V, 60Hz, 3Ph (Commercial) - ( Units Only) A = 265V, 60Hz, 1Ph (Commercial) - ( Units Only) 9 = 115V, 60Hz, 1Ph (Commercial) - ( Units Only) 8: Voltage 10: Return Air Options 9: Hot Water Configuration 12: Blower Options 11: Discharge Air Options B 1 1 L M 0 B SS Hot Water Configuration: 0 = None 1 = Desuperheater w/factory Installed Pump ( , 208/230V Units Only) 5 = Desuperheater w/o Factory Installed Pump (265V, 460V, 575V Units Only) Standard: SS = Stock Standard RS = Factory Installed Soft Starter (1Ph, Units ONLY) NS = Commercial Duct Flanges Source HX Options: C = Copper Coax N = CuproNickel Coax B = Braze Plate ( Units Only) Blower Options: 0 = PSC Motor 1 = ECM Motor (Constant CFM) (Not Available in 115V or 575V) ( Units Only) Discharge Air Options: M = Multi-Position Return Air Options: L = Left Return Air R = Right Return Air 14 & 15: Standard 13: Source HX Options ZT Model Nomenclature Brand: G = GeoComfort H = Hydron Module T = TETCO A = GeoExcel 1: Brand Type: Z = Horizontal 2: Type Stage: T = Two Stage - R-410a 3: Stage - Z T 048 Unit Capacity (Nominal MBTUH): 024, 030, 036, 042, 048, 060, 072 Revision: B = Current Revision 4, 5, 6: Unit Capacity 7: Revision Voltage: 1 = 208/230V, 60Hz, 1Ph (Residential) 0 = 208/230V, 60Hz, 1Ph (Commercial) 2 = 208/230V, 60Hz, 3Ph (Commercial) 3 = 460V, 60Hz, 3Ph (Commercial) A = 265V, 60Hz, 1Ph (Commercial) ( & Units Only) 8: Voltage 9: Hot Water Configuration 10: Return Air Options 12: Blower Options 11: Discharge Air Options B 1 1 L M 1 B SS Hot Water Configuration: 0 = None 1 = Desuperheater w/factory Installed Pump 5 = Desuperheater w/o Factory Installed Pump (265V & 460V Units Only) Standard: SS = Stock Standard RS = Factory Installed Soft Starter (1Ph Units ONLY) NS = Commercial Duct Flanges Source HX Options: C = Copper Coax N = CuproNickel Coax B = Braze Plate Blower Options: 1 = ECM Motor Discharge Air Options: M = Multi-Position Return Air Options: L = Left Return Air R = Right Return Air 14 & 15: Standard 13: Source HX Options 9

10 AHRI Performance Data ZT Two Stage, ECM Blower, Braze Plate UNIT RATING TYPE F/L COOL F/L EER F/L HEAT F/L COP P/l COOL P/L EER P/L HEAT P/L COP ZT024 ZT030 ZT036 ZT042 ZT048 ZT060 ZT072 WL 25, , , , GL 26, , , , WL 30, , , , GL 32, , , , WL 36, , , , GL 38, , , , WL 41, , , , GL 42, , , , WL 47, , , , GL 49, , , , WL 59, , , , GL 61, , , , WL 68, , , , GL 70, , , , ZS Single Stage, ECM Blower UNIT RATING TYPE F/L COOL F/L EER F/L HEAT F/L COP ZS015 ECM ZS017 ECM ZS018 ECM ZS024 ECM ZS030 ECM ZS036 ECM ZS042 ECM ZS048 ECM ZS060 ECM ZS072 ECM WL WL WL WL WL WL WL WL WL WL 14,600 17,300 19,900 25,000 29,500 36,800 42,500 48,100 59,300 69, ,700 20,400 22,600 29,300 33,000 43,300 49,600 58,100 74,700 88, GL GL GL GL GL GL GL GL GL GL 15,200 18,100 20,800 26,100 30,700 38,400 44,100 50,400 60,700 72, ,900 13,000 14,200 18,600 21,500 27,600 32,200 37,800 48,200 56,

11 AHRI Performance Data ZS Single Stage, PSC Blower ENGINEERING SPECIFICATIONS: UNIT RATING TYPE F/L COOL F/L EER F/L HEAT F/L COP ZS 006 PSC 208/230V ONLY ZS006 PSC 265/115V ONLY ZS009 PSC 208/230V ONLY ZS009 PSC 265/115V ONLY ZS012 PSC ZS015 PSC ZS017 PSC ZS018 PSC ZS024 PSC ZS030 PSC ZS036 PSC ZS042 PSC ZS048 PSC ZS060 PSC ZS072 PSC WL 6, GW 7, GL 6, WL 6, GW 7, GL 6, WL 9, GW 10, GL 9, WL 8, GW 10, GL 9, WL 11, GW 12, GL 11, WL 14, GL 15, WL 17, GL 18, WL 19, GL 20, WL 24, GL 25, WL 29, GL 30, WL 35, GL 37, WL 41, GL 43, WL 46, GL 48, WL 58, GL 60, WL 68, GL 70,

12 Table 1: Maximum Air Velocities Location Supply Return Main Ducts 900 FPM 600 FPM Branch Ducts 700 FPM 600 FPM Grills, Registers, Diffusers 750 FPM 600 FPM Horizontal Unit Suspension All Attachments per Local Codes Typical Ductwork Connection Setup: Unit Power Disconnect Air Filter Flex Connector Return and Supply Air Duct System Supply Air Flex Connector 4 Threaded Rod Attachments Return Air Duct Collar or Optional Filter Rack Maintain duct size of supply flange for at least 12 before transitioning to size of supply plenum designed for duct system. Horizontal Unit Hose Kits Service Ball Valves Source Water In Source Water Out (Top View) ZS/ZT Hanger Bracket Shipped with Unit See Installation Instructions 20D244-01NN Optional Filter Rack Kit Installation: Installation of the optional and sold separately accessory filter rack is described in the installation instructions provided with that item. Maintenance and filter change instructions are included in the owners manual shipped with every packaged unit. Seismic Hanger Bracket PC30N (Mason Industries) -- Available from mason-industries.com TYPE 30N PRECOMPRESSED & SEISMIC RESTRAINT Install with hanger box snug to 1/4 (6mm) Seismic LDS Rubber Washer, so washer is tight to overhead surface. Upper hanger element deflects under load, leaving space on top. Washer cushions upward seismic travel. SEISMIC LDS RUBBER REBOUND WASHER UPPER ROD BY OTHERS DEFLECTION SCALE 1/4 (6mm) REX Adjust nut to provide 1/4 (6mm) 30 washer clearance after hanger is fully Seismic Rebound Steel and loaded. Bonded LDS Rubber Washer holds precompression and limits upward seismic motion. Hangers are precompressed to rated load or assigned load as required. Scale indicates deflection. 12

13 REVISION HISTORY REV DESCRIPTION ECN DATE APPROVED Horizontal Unit Suspension Hanger A Locations SETUP AND and RELEASE Dimensions N01 11/14/16 BDL LEFT HAND RETURN CABINET CORNER WITH DRAIN OUTLET 1.01 CORNER WITH DRAIN OUTLET TOP VIEW TOP VIEW FRONT OF UNIT FRONT OF UNIT RIGHT HAND RETURN CABINET CORNER WITH DRAIN OUTLET 1.01 CORNER WITH DRAIN OUTLET TOP VIEW TOP VIEW FRONT OF UNIT FRONT OF UNIT B:\ENGINEERING\RECORDS\Component Drawings\PDF\20D805-47NN REVA

14 REVISION HISTORY REV DESCRIPTION ECN DATE APPROVED Horizontal Unit Suspension Hanger A Locations SETUP AND and RELEASE Dimensions N01 10/5/16 BDL LEFT HAND RETURN CABINET CORNER WITH DRAIN OUTLET 1.01 CORNER WITH DRAIN OUTLET 1.01 CORNER WITH DRAIN OUTLET TOP VIEW TOP VIEW TOP VIEW FRONT OF UNIT FRONT OF UNIT FRONT OF UNIT RIGHT HAND RETURN CABINET CORNER WITH DRAIN OUTLET 1.01 CORNER WITH DRAIN OUTLET 1.01 CORNER WITH DRAIN OUTLET TOP VIEW TOP VIEW TOP VIEW FRONT OF UNIT FRONT OF UNIT FRONT OF UNIT B:\ENGINEERING\RECORDS\Component Drawings\PDF\20D805-46NN REVA

15 Unit Dimensional Data: REVISION ENGINEERING HISTORY SPECIFICATIONS: REV DESCRIPTION ECN DATE APPROVED C UPDATED RETURN DATA /18/17 BDL SP SP CONVERTED TO BACK DISCHARGE BP CONDENSATE DRAIN BACK ISOMETRIC VIEW BP RECEIVED AS SIDE DISCHARGE F1 H D E SP SP G1 LEFT VIEW ELECTRIC HOOKUPS ALONG THIS CORNER RIGHT VIEW 1.00 TYP. SOURCE WATER OUT S A W V SOURCE WATER IN C R P CP FRONT VIEW T HOT WATER IN (WHEN APPLICABLE) HOT WATER OUT (WHEN APPLICABLE) B LEGEND SP = Service Panel BP = Blower Service Panel CP = Control Access Panel Reference dimensional data enclosed. Units utilize FPT source water connections. Units with Desuperheater utilize FPT connections. Electrical knockouts are sized to 1/2" or 3/4" conduit. All views are shown with flanges for reference. Return duct flanges or 1" commercial filter rack are factory installed. See separate dimensional data sheet for further detail. SHOWN IN RIGHT HAND RETURN CONFIGURATION TOP VIEW All measurements are in inches. Drawings are typical, individual models may vary. Optional filter rack kits are available as needed. See separate dinmensional data sheet for details. Discharge flanges are field installed and are shipped inside of the unit. 15 G:\Drafting\Drawings\Released-Production\PDF\20D805-08NN REVC

16 REVISION HISTORY ENGINEERING SPECIFICATIONS: REV DESCRIPTION ECN DATE APPROVED D UPDATED RETURN DATA /17/17 BDL Unit Dimensional Data: SP SP RECEIVED AS SIDE DISCHARGE BP CONDENSATE DRAIN BP CONVERTED TO BACK DISCHARGE BACK ISOMETRIC VIEW H D F SP SP E 1.00 TYP. LEFT VIEW ELECTRIC HOOKUPS ALONG THIS CORNER RIGHT VIEW G V W A S SOURCE WATER OUT B HOT WATER IN (WHEN APPLICABLE) HOT WATER OUT (WHEN APPLICABLE) T CP FRONT VIEW P R C SOURCE WATER IN TOP VIEW SHOWN IN LEFT HAND RETURN CONFIGURATION LEGEND SP = Service Panel BP = Blower Service Panel CP = Control Access Panel Reference dimensional data enclosed. Units utilize FPT source water connections. Units with Desuperheater utilize FPT connections. Electrical knockouts are sized to 1/2" or 3/4" conduit. All views are shown with flanges for reference. Return duct flanges or 1" commercial filter rack are factory installed. See separate dimensional data sheet for further detail. All measurements are in inches. Drawings are typical, individual models may vary. Optional filter rack kits are available as needed. See separate dinmensional data sheet for details. Discharge flanges are field installed and are shipped inside of the unit. 16 G:\Drafting\Drawings\Released-Production\PDF\20D805-02NN REVD

17 Unit Dimensional Data: REVISION ENGINEERING HISTORY SPECIFICATIONS: REV DESCRIPTION ECN DATE APPROVED C REMOVED OPT. RACK /18/17 BDL UNIT PITCH FOR CONDENSATE DRAIN 1/4" - 1/2" Pitch Condensate Drain Notes: 1. Unit must pitch from level towards the condensate drain for proper drainage. 2. Confirm that condensate drains properly from unit and that the amount of pitch does not cause condensate leaks inside of the unit. 3. Units are equipped with overflow protection. 4. Be sure to leave adequate height for the P-Trap in applications where clearance could be an issue. 5. In some high humidity applications you may need to apply insulative tape around condensate drain fitting. CONDENSATE DRAIN FITTING PVC STUB INCLUDED WITH UNIT SEE NOTES TO THE RIGHT. G:\Drafting\Drawings\Released-Production\PDF\20D805-05NN 17 Enertech REVC Global, LLC

18 Unit Unit Dimensional Data Data: - ZS/ZT MODEL Overall Cabinet Size Supply Air (Side Blower Discharge) A (Width) B (Depth) C (Height) D (Width) E (Height) F (LHR) G (LHR) F1 (RHR) G1 (RHR) H MODEL Source Water Hot Water (If Applicable) MODEL P R S T V W N/A N/A N/A N/A N/A N/A N/A N/A N/A "-2" Optional Deluxe Filter Rack Order Item Number AFR0923A AFR0923A AFR0923A AFR1423A AFR1423A AFR1632A AFR1632A AFR1632A AFR1836A AFR1836A AFR1836A AFR1841A AFR1841A Note: 1. For Return Flange / Filter Rack Dimensional Data see additional sheet. 2. Residential Models are shipped with factory applied Return Duct Flanges. 3. Commercial Models are shipped with factory applied 1" Commercial Filter Rack. 18

19 Isometric Views: REVISION ENGINEERING HISTORY SPECIFICATIONS: REV DESCRIPTION ECN DATE APPROVED A ADD ZS-ZT INFORMATION /4/16 BDL LEFT HAND RETURN BACK ISO VIEW RIGHT HAND RETURN BACK ISO VIEW SIDE DISCHARGE CONFIGURATION SIDE DISCHARGE CONFIGURATION FIELD CONVERTED BACK DISCHARGE CONFIGURATION FIELD CONVERTED BACK DISCHARGE CONFIGURATION SIDE DISCHARGE CONFIGURATION AIR COIL AIR COIL TOP VIEW COMPRESSOR CONTROL BOX UNIT FRONT LEFT HAND RETURN UNIT FRONT RIGHT HAND RETURN G:\Drafting\Drawings\Released-Production\PDF\20D805-04NN 19 Enertech REVA Global, LLC

20 REVISION HISTORY REV DESCRIPTION ECN DATE APPROVED A ADD ZS-ZT INFORMATION /5/16 BDL Service Access Clearances: SERVICE ACCESS CLEARANCE (Shown below as Left Hand Return) A-4 ALT. SUPPLY AIR FLOW RETURN AIR FLOW A I R C O I L TOP VIEW SUPPLY AIR FLOW A-5 REVERSING VALVE TXV AND FILTER DRIER COMPRESSOR SOURCE HEAT EXCHANGER A-2 A-3 CONTROLS FRONT OF UNIT LEGEND: A-1 NOTE: For clearance requirements be sure to check your local codes as they may require more clearance than what is described below. A-1: This is the main controls and compressor access panel. Requires 2 feet of clearance. A-2: This is the txv-filter drier access area. Be sure to leave adequate clearance for any future maintenance if needed. A-3: This is the source heat exchanger reversing valve access area. Be sure to leave adequate clearance for any future maintenance if needed. A-4: This is the blower motor access when the unit is configured as side discharge. This is the configutation that the unit is shipped in. When side discharge then this access area requires 2 feet of clearance. ONLY FOR ALT. SUPPLY AIR A-5: This is the blower motor access when the unit is configured as back discharge. When back discharge then this access area requires 2 feet of clearance. G:\Drafting\Drawings\Released-Production\PDF\20D805-06NN 20D214-16NN REVA ZS/ZT Rev B

21 ZT Unit Electrical Data: ZT Model ZT024 ZT030 ZT036 ZT042 ZT048 Voltage Code/ HWG Option 60 Hz Power Compressor Fan Motor Volts Phase LRA RLA FLA HWG Pump FLA Ext. Loop Pump FLA Total Unit FLA Min Circuit AMPS / / / / / / / A / / / / / / / A / / / / / / / A / / / / / / / / / / / / / / A Max Fuse HACR Notes: 1. All line and low voltage wiring must adhere to the National Electrical Code and local codes, whichever is the most stringent. 2. In determining the correct supply wire size and maximum length, reference NFPA 70, Section 310. If the calculation is close to the maximum allowable ampacity of a particular wire size, use the next size up. This will ensure that no adverse effects occur, such as light dimming and/or shortened compressor life. 3. All fuses class RK Min/Max Voltage: 208/230/60 = , 460/60 = , 265/60 = See Wiring Diagrams for proper 460V power. *The external loop pump FLA is based on a maximum of three UP26-116F-230V pumps (1/2hp) for and two pumps for

22 ZT Unit Electrical Data: ZT ZT060 ZT / / / / / / / A / / / / / / / Notes: 1. All line and low voltage wiring must adhere to the National Electrical Code and local codes, whichever is the most stringent. 2. In determining the correct supply wire size and maximum length, reference NFPA 70, Section 310. If the calculation is close to the maximum allowable ampacity of a particular wire size, use the next size up. This will ensure that no adverse effects occur, such as light dimming and/or shortened compressor life. 3. All fuses class RK Min/Max Voltage: 208/230/60 = , 460/60 = , 265/60 = See Wiring Diagrams for proper 460V power. *The external loop pump FLA is based on a maximum of three UP26-116F-230V pumps (1/2hp) for and two pumps for

23 ZS - ECM Unit Electrical Data: Model ZS015 ZS017 ZS018 ZS024 ZS030 ZS036 Voltage Code/ HWG Option 60 Hz Power Compressor Fan Motor Volts Phase LRA RLA FLA HWG Pump FLA Ext. Loop Pump FLA Total Unit FLA Min Circuit AMPS Max Fuse HACR / / / / A / / / / A / / / / A / / / / / / / A / / / / / / / A / / / / / / / A Notes: 1. All line and low voltage wiring must adhere to the National Electrical Code and local codes, whichever is the most stringent. 2. In determining the correct supply wire size and maximum length, reference NFPA 70, Section 310. If the calculation is close to the maximum allowable ampacity of a particular wire size, use the next size up. This will ensure that no adverse effects occur, such as light dimming and/or shortened compressor life. 3. All fuses class RK Min/Max Voltage: 208/230/60 = , 460/60 = , 265/60 = See Wiring Diagrams for proper 460V power. *The external loop pump FLA is based on a maximum of three UP26-116F-230V pumps (1/2hp) for and two pumps for

24 ZS - ECM Unit Electrical Data: Model ZS042 ZS048 ZS060 Voltage Code/ HWG Option 60 Hz Power Compressor Fan Motor Volts Phase LRA RLA FLA HWG Pump FLA Ext. Loop Pump FLA Total Unit FLA Min Circuit AMPS Max Fuse HACR / / / / / / / / / / / / / / / / / / / / / / / / ZS / / / / Notes: 1. All line and low voltage wiring must adhere to the National Electrical Code and local codes, whichever is the most stringent. 2. In determining the correct supply wire size and maximum length, reference NFPA 70, Section 310. If the calculation is close to the maximum allowable ampacity of a particular wire size, use the next size up. This will ensure that no adverse effects occur, such as light dimming and/or shortened compressor life. 3. All fuses class RK Min/Max Voltage: 208/230/60 = , 460/60 = , 265/60 = See Wiring Diagrams for proper 460V power. *The external loop pump FLA is based on a maximum of three UP26-116F-230V pumps (1/2hp) for and two pumps for

25 ZS - PSC Unit Electrical Data: Model ZS006 ZS009 ZS012 ZS015 ZS017 ZS018 ZS024 Voltage Code/ HWG Option 60 Hz Power Compressor Volts Phase LRA RLA Fan Motor FLA HWG Pump FLA Ext. Loop Pump FLA Total Unit FLA Min Circuit AMPS / / A / / A / / A / / / / A / / / / A / / / / A / / / / / / / / A / / / / ZS / / / / A Notes: 1. All line and low voltage wiring must adhere to the National Electrical Code and local codes, whichever is the most stringent. 2. In determining the correct supply wire size and maximum length, reference NFPA 70, Section 310. If the calculation is close to the maximum allowable ampacity of a particular wire size, use the next size up. This will ensure that no adverse effects occur, such as light dimming and/or shortened compressor life. 3. All fuses class RK Min/Max Voltage: 208/230/60 = , 460/60 = , 265/60 = , 115/60 = 108/ See Wiring Diagrams for proper 460V power. *The external loop pump FLA is based on a maximum of three UP26-116F-230V pumps (1/2hp) for and two Max Fuse HACR 25

26 ZS - PSC Unit Electrical Data: Model ZS036 ZS042 ZS048 ZS060 Voltage Code/ HWG Option 60 Hz Power Compressor Fan Motor Volts Phase LRA RLA FLA HWG Pump FLA Ext. Loop Pump FLA Total Unit FLA Min Circuit AMPS Max Fuse HACR / / / / / / / / A / / / / / / / / / / / / / / / / / / / / / / / / / / / ZS / / / / / Notes: 1. All line and low voltage wiring must adhere to the National Electrical Code and local codes, whichever is the most stringent. 2. In determining the correct supply wire size and maximum length, reference NFPA 70, Section 310. If the calculation is close to the maximum allowable ampacity of a particular wire size, use the next size up. This will ensure that no adverse effects occur, such as light dimming and/or shortened compressor life. 3. All fuses class RK Min/Max Voltage: 208/230/60 = , 460/60 = , 265/60 = , 115/60 = See Wiring Diagrams for proper 460V power. *The external loop pump FLA is based on a maximum of three UP26-116F-230V pumps (1/2hp) for and two pumps for

27 Model Series Model Number Unit Weight Tare Weight Shipped Unit Weight Left Return Corner A (Unit Wt.) Left Return Corner B (Unit Wt.) Left Return Corner C (Unit Wt.) Left Return Corner D (Unit Wt.) Right Return Corner A (Unit Wt.) Right Return Corner B (Unit Wt.) Right Return Corner C (Unit Wt.) Right Return Corner D (Unit Wt.) ZS-ZT Compact Horizontal Packaged Unit UNIT WEIGHT DATA (lbs) A C Horizontal Unit Corner Assignment B D UNIT FRONT Horizontal - ZT Model Number Compressor Type Dual Stage Scroll Compressor Blower/Fan Wheel (in.) 10 x 8T 10 x 8T 10 x 8 10 x 8 10 x 8 Fan Motor ECM (HP) Source Water Conn. 1/2 1" FPT 1/2 1" FPT 1/2 1" FPT 3/4 1" FPT 3/4 1" FPT HWG Water (if applicable) 3/4" FPT 3/4" FPT 3/4" FPT 3/4" FPT 3/4" FPT Refrigerant Charge (oz.) * Air Coil Face Area (Sq. Ft.) Dimensions (in.) Number of Rows x 15.5 x x 17.4 x x 17.4 x 1 Micro-channel Coil * Always check the unit data plate for specific charge volume Horizontal - ZS Model Number Compressor Type Single Stage Rotary Compressor Blower/Fan Wheel (in.) 6 x 9 6 x 9 6 x 9 9 x 7T 9 x 7T Fan Motor ECM (HP) N/A N/A N/A 1/2 1/2 Fan Motor PSC (HP) 1/16 1/16 1/16 1/4 1/4 Source Water Conn. 3/4" FPT 3/4" FPT 3/4" FPT 3/4" FPT 3/4" FPT HWG Water (if applicable) N/A N/A N/A 3/4" FPT 3/4" FPT Refrigerant Charge (oz.) * Air Coil Face Area (Sq. Ft.) Dimensions (in.) 20.5 x 7.6 x x 12.6 x 1.26 Number of Rows Micro-channel Coil * Always check the unit data plate for specific charge volume Horizontal - ZS Model Number Compressor Type Single Stage Scroll Compressor Blower/Fan Wheel (in.) 10 x 8T 10 x 8T 10 x 8T 10 x 8 10 x 8 10 x 8 11 x 10T 11 x 10T Fan Motor ECM (HP) 1/2 1/2 1/2 1/2 1/2 3/4 1 1 Fan Motor PSC (HP) 1/4 1/3 1/3 1/3 1/2 3/4 1 1 Source Water Conn. 1" FPT 1" FPT 1" FPT 1" FPT 1" FPT 1" FPT 1" FPT 1" FPT HWG Water (if applicable) 3/4" FPT 3/4" FPT 3/4" FPT 3/4" FPT 3/4" FPT 3/4" FPT 3/4" FPT 3/4" FPT Refrigerant Charge (oz.) * Air Coil Face Area (Sq. Ft.) Dimensions (in.) 30.3 x 15.5 x x 17.4 x x 17.4 x 1 Number of Rows Micro-channel Coil * Always check the unit data plate for specific charge volume x 10T 11 x 10T 1 1 1" FPT 1" FPT 3/4" FPT 3/4" FPT

28 ECM Fan Performance: *ZS/*ZT Series ECM Fan Performance Data: One & Two Stage Compressor Units Model Max Dehumidification AUX/ ESP Program 3 Heating Mode Cooling Mode Fan Mode EMG DIP Switch Settings Only in. w.c. 2 1st 2nd 1st 2nd 1st 2nd Heat 4 S1 S2 S3 S4 S5 S6 S7 S8 A OFF OFF OFF OFF OFF OFF OFF OFF B ON OFF OFF OFF ON OFF OFF OFF N/A C OFF ON OFF OFF OFF ON OFF OFF D ON ON OFF OFF ON ON OFF OFF A OFF OFF ON OFF OFF OFF OFF OFF B OFF OFF OFF OFF OFF OFF OFF OFF N/A C ON OFF OFF OFF ON OFF OFF OFF D OFF ON OFF OFF OFF ON OFF OFF A OFF ON OFF OFF OFF ON OFF OFF B OFF ON OFF ON OFF ON OFF OFF C ON ON ON OFF ON ON OFF OFF D ON ON OFF OFF ON ON OFF OFF A OFF OFF ON OFF OFF OFF OFF OFF B OFF OFF OFF OFF OFF OFF OFF OFF C OFF OFF OFF ON OFF OFF OFF OFF D ON OFF ON OFF ON OFF OFF OFF A OFF OFF OFF OFF OFF OFF OFF OFF B OFF OFF OFF ON OFF OFF OFF OFF C ON OFF ON OFF ON OFF OFF OFF D ON OFF OFF OFF ON OFF OFF OFF A OFF OFF OFF OFF OFF OFF OFF OFF B ON OFF OFF OFF ON OFF OFF OFF C OFF ON OFF OFF OFF ON OFF OFF D ON ON OFF OFF ON ON OFF OFF A ON OFF OFF OFF ON OFF OFF OFF B ON OFF OFF ON ON OFF OFF OFF C ON ON OFF OFF ON ON OFF OFF D ON ON OFF ON ON ON OFF OFF A OFF OFF OFF OFF OFF OFF OFF OFF B ON OFF ON OFF ON OFF OFF OFF C ON OFF OFF OFF ON OFF OFF OFF D ON ON ON OFF ON ON OFF OFF A OFF OFF ON OFF OFF OFF OFF OFF B OFF OFF OFF OFF OFF OFF OFF OFF C OFF OFF OFF ON OFF OFF OFF OFF D ON OFF ON OFF ON OFF OFF OFF A N/A B OFF OFF ON OFF OFF OFF OFF OFF C OFF OFF OFF OFF OFF OFF OFF OFF D OFF OFF OFF ON OFF OFF OFF OFF Notes: 1. Program B (Bold Type) is factory settings and rated CFM. CFM is controlled within 5% up to the Max ESP. 2. Max ESP includes allowance for wet coil and NO FILTER 3. Power must be off to the unit for at least 3 seconds before the ECM motor will recognize a program change. 4. Max ESP for ZS018 through ZS/ZT036 models with external electric heat is 0.8 in. w.c.; for ZS/ZT048 models it is 0.9 in. w.c.; and for ZS/ZT060 and ZS/ZT072 it is 1.1 in. w.c. Exceeding the Max ESP may result in nuisance trips of the electric heat. Thermal limits are rated at 100,000 cycles. *ZS/*ZT Series Dehumidification Mode Options DIP Switch S9 S10 Mode Operation ON OFF Normal Dehumidification mode disabled (Normal Htg/Clg CFM) Factory setting. OFF ON ODD On Demand Dehumidification mode (humidistat input at terminal ODD) Humidistat required. OFF OFF Constant Dehum Constant Dehumidification mode (always uses dehum CFM for cooling and normal CFM for heating) No humidistat required. ON ON Not Used Not an applicable selection. Notes: 1. To enter dehumidification mode, ODD input should be 0 VAC; for normal cooling CFM, ODD input should be 24 VAC. 2. Heating CFM is not affected by dehumidification mode. When in dehumidification mode, cooling CFM is 85% of normal CFM. 28

29 PSC Fan Performance: Model 006/009 /012 CFM Nominal H 350 (009/012 2 ) M/H M/L 6 x 9 1/ (006) L H 650 (017) M 525 (015) L H M 600 (018) L H 1000 (030) M 10 x 8T 1/3 750 (024) L H M 1/ L H M L H M L H 2200 (072) M 1900 (060) L x 8T 1/4 024/030 Motor Speed 1 Blower Size 015/017 9 x 7T 1/ x 8 Motor HP x 8 1/ x 8 3/4 060/ x 10 1 *ZS Series PSC Fan Performance Data Static Pressure (inches w.c.) Notes: 1. PSC Blower motors come with 3 or 4 speed taps. To change the speed of the motor to a higher or lower speed, remove the electric box cover that is mounted on the blower. Locate the label on the motor to identify the wire color for each speed. Remove the wire nut on the existing speed and replace with the wire of selected speed. 2. Running the ZS012 at the static/scfm points highlighted in gray, is not recommended. 3. Max ESP and speed settings for ZS models with external electric heat is shown below. Exceeding the Max ESP may result in nuisance trips of the electric heat. Thermal limits are rated at 100,000 cycles. Model / /072 *ZS Series Electric Heat Limitations Electric Heater AXCH051MB AXCH051MB X 0.7 X 0.8 X 0.7 X 0.8 Speed Max High Med Low Static AXCH101MB X 0.8 AXCH051MB X 0.8 X 0.9 AXCH101MB X 0.8 AXCH051MB X X X 0.9 X 0.7 AXCH101MB X 0.8 X 0.9 AXCH101MB X X X 0.9 AXCH151MB X X 0.9 AXCH101LB X X X 1.0 AXCH151LB X X 0.9 X

30 Filter Performance: The blower performance data in the ECM Blower Performance table is WITHOUT FILTER. To determine the approximate blower performance WITH FILTER apply the filter pressure drop value for the filter being used or calculate the pressure drop as follows: Below is typical filter performance data and should only be used as a guideline. Actual performance may vary between manufacturers. Return Size Height Width Area Model (in.) (in.) (ft 2 ) Rated Initial Filter 024 Thickness Velocity Resistance Type 036 (in) 28 (fpm) 26 (in.w.c.) MERV MERV MERV Example: For an YT036 at an air flow of 1420 CFM calculate the filter pressure drop with a 2 MERV 13 filter and determine Total ESP and compare to Max ESP. CFM = 1420 Area = 5.1 ft2 Rated Velocity = 500 fpm Initial Resistance = 0.43 in.w.c. Measured ESP without filter = CFM 5.1 ft2 = 278 fpm fpm 500 fpm = x 0.43 in.w.c. = 0.24 in.w.c. = Filter Pressure Drop 4. Total ESP is = 0.6 in.w.c. which is less than the 1.1 in.w.c. Max ESP To calculate filter pressure drop: Applying Filter Pressure Drop to Determine Total ESP To determine the Total ESP of a unit with the filter in place, follow the steps below: 1. Select the filter type and determine Rated Velocity and Initial Resistance 2. For the model being considered determine Max ESP, CFM and Return Area 3. Determine Filter pressure drop (ΔPs) using the equation above 4. Measure (or calculate) the ESP without filter in place 5. Calculate Total ESP = Measured ESP + Filter Pressure Drop 6. Total ESP should be less than or equal to Max ESP Example: For an YT060 at an air flow of 1960 CFM calculate the filter pressure drop with a 2 MERV 11 filter and determine Total ESP and compare to Max ESP. CFM = 1960 Area = 5.8 ft2 Rated Velocity = 500 fpm Initial Resistance = 0.24 in.w.c. Measured ESP without filter = CFM 5.8 ft2 = 338 fpm fpm 500 fpm = x 0.24 in.w.c. = 0.16 in.w.c. = Filter Pressure Drop 4. Total ESP is = 0.69 in.w.c. which is less than the 1.2 in.w.c. Max ESP 30

31 Glossary of Terms: ASC = Anti-Short Cycle AFRZ = Anti-Freeze CFM = Airflow, Cubic Feet/Minute CO = Condensate Overflow COP = Coefficient of Performance = BTU Output / BTU input DGT = Hot Discharge Gas Temperature DH = Desuperheater Capacity, Btu/hr DLWT = Domestic Leaving Water Temperature EAT = Entering Air Temperature, Fahrenheit (Dry/Wet Bulb) ECM = Electronically Commutated Motors EER = Energy Efficiency Ratio = BTU output/watts input ELT = Entering Load Water Temperature, Fahrenheit EWT = Entering Source Water Temperature, Fahrenheit FS = Factory Setting FSW Flow Switch GPM = Water Flow, Gallons Per Minute HC = Total Heating Capacity, Btu/hr HE = Total Heat Of Extraction, Btu/hr HGT = Hot Gas Temperature HP = High Pressure HR = Total Heat Of Rejection, Btu/hr HWG = Hot Water Generator KW = Total Power Unit Input, Kilowatts LAT = Leaving Air Temperature, Fahrenheit LC = Latent Cooling Capacity, Btu/hr LCT = Load Coil (Heat Exchanger) Temperature (Freeze) LLT = Leaving Load Water Temperature, Fahrenheit LP = Low Pressure LWT = Leaving Source Water Temperature, Fahrenheit O/U = Over/Under ODD = On Demand Dehumidification SC = Sensible Cooling Capacity, Btu/hr SCT Source Coil (Heat Echanger) Temperature (Freeze) TC = Total Cooling Capacity, Btu/hr TEST = Test Mode WPD = Water Pressure Drop, PSI & Feet of Water Sensible Cooling Correction Factors: EAT (WB) F EAT (DB) F Cooling Correction Factors: EAT (WB) F TC HR kw Heating & Cooling Calculations: Heating Correction Factors: Heating LAT = EAT + HC CFM x 1.08 LWT = EWT - HE GPM x 500 LC = TC - SC Cooling LAT (DB) = EAT (DB) - SC CFM x 1.08 LWT = EWT + HR GPM x 500 EAT F HC HE kw

32 Water Flow Selection: Proper flow rate is crucial for reliable operation of geothermal heat pumps. The performance data shows three flow rates for each entering water temperature (EWT column). The general rule of thumb when selecting flow rates is the following: Top flow rate: Open loop systems (1.5 to 2.0 gpm per ton) Middle flow rate: Minimum closed loop system flow rate (2.25 to 2.50 gpm/ton) Bottom flow rate: Nominal (optimum) closed loop system flow rate (3.0 gpm/ton) Although the industry standard is adequate in most areas of North America, it is important to consider the application type before applying this rule of thumb. Antifreeze is generally required for all closed loop (geothermal) applications. Extreme Southern U.S. locations are the only exception. Open loop (well water) systems cannot use antifreeze, and must have enough flow rate in order to avoid freezing conditions at the Leaving Source Water Temperature (LWT) connection. Calculations must be made for all systems without antifreeze to determine if the top flow rate is adequate to prevent LWT at or near freezing conditions. The following steps should be taken in making this calculation: Determine minimum EWT based upon your geographical area. Go to the performance data table for the heat pump model selected and look up the Heat of Extraction (HE) at the rule of thumb water flow rate (GPM) and at the design Entering Air Temperature (EAT). Calculate the temperature difference (TD) based upon the HE and GPM of the model. TD = HE / (GPM x 485). Calculate the LWT. LWT = EWT - TD. If the LWT is below F, there is potential for freezing conditions if the flow rate or water temperature is less than ideal conditions, and the flow rate must be increased. Example 1: EWT = 50 of Model YT036, full load. Flow rate = 4.5 GPM. Air Flow = 1380 CFM. HE = 29,400 Btuh. TD = 29,400 / (4.5 x 485) = 13.5 of LWT = = 36.5 of Water flow rate is acceptable. Performance Data Tables and Notes: 1. Capacity data is based on 15% (by mass) methanol antifreeze solution (multiplier: 485). 2. Heating data is based on 70 F EAT. Cooling data is based on 80/67 F EAT. Any condition outside performance table(s) requires correction factor(s). 3. Performance data accurate within ±15%. 4. Unit performance test is run without hot water generation. 5. Desuperheater capacity is based upon 2.0 GPM water flow at 70 of entering water temperature. 6. Capacity data includes fan power but not pump power and it does not reflect fan or pump power correction for AHRI/ISO conditions. 7. Performance data is based upon the lower voltage of dual voltage rated units. 8. Interpolation of unit performance data is permissible; extrapolation is not. 9. Performance data is a result of lab testing and is not related to warranty. 10. Due to variations in installation, actual unit performance may vary from the tabulated data. 11. See Flow Rate Selection above for proper application. 12. Continuous research and development may result in a change to the current product design and specifications without notice. Example 2: EWT = 40 of Model YT036, full load. Flow rate = 4.5 GPM. Air Flow = 1380 CFM. HE = 25,300 Btuh. TD = 25,300 / (4.5 x 485) = 11.6 of LWT = = 28.4 of Water flow rate must be increased to avoid freezing. 32

33 ZT SC/SH Tables Full Load Heating - No Hot Water Generation ZT024 ZT030 ZT036 ZT042 ZT048 ZT060 ZT072 SC SH SC SH SC SH SC SH SC SH SC SH SC SH F GPM/Ton F F F F F F F F F F F F F F Full Load Cooling - No Hot Water Generation ZT024 ZT030 ZT036 ZT042 ZT048 ZT060 ZT072 SC SH SC SH SC SH SC SH SC SH SC SH SC SH F GPM/Ton F F F F F F F F F F F F F F Part Load Heating - No Hot Water Generation ZT024 ZT030 ZT036 ZT042 ZT048 ZT060 ZT072 SC SH SC SH SC SH SC SH SC SH SC SH SC SH F GPM/Ton F F F F F F F F F F F F F F Part Load Cooling - No Hot Water Generation ZT024 ZT030 ZT036 ZT042 ZT048 ZT060 ZT072 SC SH SC SH SC SH SC SH SC SH SC SH SC SH F GPM/Ton F F F F F F F F F F F F F F Heating data based on 70 F EAT. Cooling data based on 80/67 F EAT. CFM is typically CFM/Ton for heating and cooling. SC=Subcooling; SH=Superehat 33

34 ZT Models Performance Tables Model ZT024, 2 Ton, Full Load Performance Data: WPD Full Load Heating Full Load Cooling Operation not recommended Operation not recommended

35 Model ZT024, 2 Ton, Part Load Performance Data: WPD Part Load Heating Part Load Cooling

36 ZT Models Performance Tables Model ZT030, 2.5 Ton, Full Load Performance Data: WPD Full Load Heating Full Load Cooling Operation not recommended Operation not recommended

37 ZT Models Performance Tables Model ZT030, 2.5 Ton, Part Load Performance Data: WPD Part Load Heating Part Load Cooling

38 ZT Models Performance Tables Model ZT036, 3 Ton, Full Load Performance Data: WPD Full Load Heating Full Load Cooling Operation not recommended Operation not recommended

39 ZT Models Performance Tables Model ZT036, 3 Ton, Part Load Performance Data: WPD Part Load Heating Part Load Cooling

40 ZT Models Performance Tables Model ZT040, 3.5 Ton, Full Load Performance Data: WPD Full Load Heating Full Load Cooling Operation not recommended Operation not recommended

41 ZT Models Performance Tables Model ZT042, 3.5 Ton, Part Load Performance Data: WPD Part Load Heating Part Load Cooling

42 ZT Models Performance Tables Model ZT048, 4 Ton, Full Load Performance Data: WPD Full Load Heating Full Load Cooling

43 ZT Models Performance Tables Model ZT048, 4 Ton, Part Load Performance Data: WPD Part Load Heating Part Load Cooling

44 ZT Models Performance Tables Model ZT060, 5 Ton, Full Load Performance Data: WPD Full Load Heating Full Load Cooling

45 ZT Models Performance Tables Model ZT060, 5 Ton, Part Load Performance Data: WPD Part Load Heating Part Load Cooling

46 ZT Models Performance Tables Model ZT072, 6 Ton, Full Load Performance Data: WPD Full Load Heating Full Load Cooling

47 ZT Models Performance Tables Model ZT072, 6 Ton, Part Load Performance Data: WPD Part Load Heating Part Load Cooling

48 ZS Models Performance Tables Model ZS006,.5 Ton, w/psc, Full Load Performance Data: WPD Heating Cooling

49 ZS Models Performance Tables Model ZS009,.75 Ton, w/psc, Full Load Performance Data: WPD Heating Cooling

50 ZS Models Performance Tables Model ZS012, 1 Ton, w/psc, Full Load Performance Data: WPD Heating Cooling

51 ZS Models Performance Tables Model ZS015, 1.25 Ton, w/psc, Full Load Performance Data: WPD Heating Cooling

52 ZS Models Performance Tables Model ZS017, 1.5 Ton, w/psc, Full Load Performance Data: WPD Heating Cooling

53 ZS Models Performance Tables Model ZS018, 1.5 Ton, w/psc, Full Load Performance Data: WPD Heating Cooling

54 ZS Models Performance Tables Model ZS024, 2 Ton, w/psc, Full Load Performance Data: WPD Heating Cooling

55 ZS Models Performance Tables Model ZS030, 2.5 Ton, w/psc, Full Load Performance Data: WPD Heating Cooling

56 ZS Models Performance Tables Model ZS036, 3 Ton, w/psc, full Load Performance Data: WPD Heating Cooling

57 ZS Models Performance Tables Model ZS042, 3.5 Ton, w/psc, Full Load Performance Data: WPD Heating Cooling

58 ZS Models Performance Tables Model ZS048, 4 Ton, w/psc, Full Load Performance Data: WPD Heating Cooling

59 ZS Models Performance Tables Model ZS060, 5 Ton, w/psc, Full Load Performance Data: WPD Heating Cooling

60 ZS Models Performance Tables Model ZS072, 6 Ton, w/psc, full Load Performance Data: WPD Heating Cooling

61 ZS Models Performance Tables Model ZS015, w/ecm, Full Load Performance Data: WPD Heating Cooling

62 ZS Models Performance Tables Model ZS017, w/ecm, Full Load Performance Data: WPD Heating Cooling

63 ZS Models Performance Tables Model ZS018, 1.5 Ton, w/ecm, Full Load Performance Data: WPD Heating Cooling

64 ZS Models Performance Tables Model ZS024, 2 Ton, w/ecm, Full Load Performance Data: WPD Heating Cooling

65 ZS Models Performance Tables Model ZS030, 2.5 Ton, w/ecm, Full Load Performance Data: WPD Heating Cooling

66 ZS Models Performance Tables Model ZS036, 3 Ton, w/ecm, Full Load Performance Data: WPD Heating Cooling

67 ZS Models Performance Tables Model ZS042, 3.5 Ton, w/ecm, Full Load Performance Data: WPD Heating Cooling

68 ZS Models Performance Tables Model ZS048, 4 Ton, w/ecm, Full Load Performance Data: WPD Heating Cooling

69 ZS Models Performance Tables Model ZS060, 5 Ton, w/ecm, Full Load Performance Data: WPD Heating Cooling

70 ZS Models Performance Tables Model ZS072, 6 Ton, w/ecm, full Load Performance Data: WPD Heating Cooling

71 This page Intentionally Left Blank ENGINEERING SPECIFICATIONS: 71

72 Greenville, IL - Mitchell, SD info@enertechgeo.com MEMBER Rev Tab 20D214-16NN B

ENGINEERING SPECIFICATIONS:

ENGINEERING SPECIFICATIONS: Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS VS/VT 006-072 VERTICAL PACKAGED SYSTEMS WATER-TO-AIR HEAT PUMPS Unit Tag Model Number

More information

Engineering Data Submittal Manual

Engineering Data Submittal Manual Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: WS/WD MODELS 036-360 WATER-TO-WATER HEAT PUMPS Unit Tag Model Number Revision: A 20D214-11NN

More information

Engineering Data Submittal Manual

Engineering Data Submittal Manual Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS RT 024-060 OUTDOOR SPLIT COMPRESSOR SECTION WATER-TO-AIR HEAT PUMPS Unit Tag Model

More information

Engineering Data Submittal Manual

Engineering Data Submittal Manual Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS XT 024-072 VERTICAL PACKAGED SYSTEMS WATER-TO-AIR HEAT PUMPS Unit Tag Model Number

More information

Engineering Data Submittal Manual

Engineering Data Submittal Manual Engineering Data Submittal Manual Project Name: Engineer: Contractor: Architect: Date Received: Date Submitted: MODELS HT 024-060 HORIZONTAL PACKAGED SYSTEMS WATER-TO-AIR HEAT PUMPS 20D214-06NN 20D214-06NN

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton

i Series Model SV Water Source Heat Pump 1/2 to 6 Ton i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features

More information

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications

CDI series. Engineering Submittal Sheet. Model SM Residential Geothermal Heat Pump. Standard Features. Overview and Certifications CDI series Model SM Residential Geothermal Heat Pump Engineering Submittal Sheet Overview and Certifications Standard Features and Field Installed Accessories Standard Features White Pre-Painted Sheet

More information

EMIP60 ISO. EM Series, Inch Pounds - 60 Hz EM (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating.

EMIP60 ISO. EM Series, Inch Pounds - 60 Hz EM (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating. EMIP60 ISO EM Series, Inch Pounds 60 Hz EM007360 (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating Rev 1003 Revisions: 81402 Changed EM170/240HZ dwg 31103 Changed HZ dwg to

More information

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

GUIDE SPECIFICATIONS CE Series Two Stage R-410A GUIDE SPECIFICATIONS CE Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall

More information

Si Series Model CE Residential Geothermal Heat Pump

Si Series Model CE Residential Geothermal Heat Pump Si Series Model CE Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features CE Model 025-071 5 Models: 025,

More information

GUIDE SPECIFICATIONS. ES Series R-410A

GUIDE SPECIFICATIONS. ES Series R-410A GUIDE SPECIFICATIONS ES Series R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump and Ground Loop Pump applications. Units shall be Underwriter

More information

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers GUIDE SPECIFICATIONS WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers WW024-072 Reverse Cycle Chillers / Low Temperature Boilers GENERAL Units shall be Underwriter Laboratories (UL) listed

More information

WATER SOURCE HEAT PUMPS

WATER SOURCE HEAT PUMPS HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1 2-5 tons ship as factory-charged packages. Horizontal (HWP) units

More information

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS TECHNICAL GUIDE HIGH-EFFICIENCY WATER SOURCE H PUMPS AND WATER COOLED AIR CONDITIONERS HORIZONTAL & VERTICAL MODELS 1/2-5 TONS GENERAL All Models 1/2-5 tons ship as factory-charged packages. Horizontal

More information

Specification Manual Ground Source Heat Pumps Northern Geo LLC 75 West Veum Appleton, MN

Specification Manual Ground Source Heat Pumps Northern Geo LLC 75 West Veum Appleton, MN Specification Manual Ground Source Heat s www.northernheatpump.com Northern Geo LLC 75 West Veum Appleton, MN 56208 320-297-9100 info@northerngeo.com 07/30/2015 NL003 NorthStar Series Features & Benefits

More information

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: 036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections

More information

LV MODEL. LV Model Water Source Heat Pump. 1/2 to 6 ton

LV MODEL. LV Model Water Source Heat Pump. 1/2 to 6 ton boschheatingandcooling.com 1 LV Model Water Source Heat Pump 1/2 to 6 ton The option-rich, water-to-air LV offers one of the smallest cabinets in the industry, making it a great choice for replacement

More information

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL

RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAV Sales Guide FAN COIL UNITS HI-RISE, VERTICAL RAVS RARM RARS RAVE RAVM RAVL RARP RISER www.superiorrex.com RAV Series: VERTICAL HI-RISE CONCEALED SO TOUGH, WE GUARANTEE IT! www.superiorrex.com Model

More information

Specification Manual

Specification Manual Specification Manual Ground Source Heat s www.northernheatpump.com Northern Geo LLC 75 West Veum Appleton, MN 56208 320-297-9100 info@northerngeo.com 09/03/2014 NL003 NorthStar Series Features & Benefits

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

McQuay Enfinity TM. Horizontal & Vertical Water Source Heat Pump 1/2 to 5 Ton. Catalog

McQuay Enfinity TM. Horizontal & Vertical Water Source Heat Pump 1/2 to 5 Ton. Catalog Catalog 1100-6 McQuay Enfinity TM Horizontal & Vertical Water Source Heat Pump 1/2 to 5 Ton Model CCH & CCW Ceiling Concealed Size 007 060 Model FCV & FCW Vertical Floor Size 007 060 Table of Contents

More information

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S P R O D U C T S P E C I F I C AT I O N S A I R H A N D L E R S CB6UH-R MERIT Series R- - Upflow / Horizontal Bulletin No. 1067 April 01 Supersedes January 01 Nominal Capacity - 1.5 to 5 Tons Optional Electric

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air Conditioning SUBMITTAL SET LX ULTRA COMMERCIAL GEOTHERMAL/ WATER SOURCE HEAT PUMPS SINGLE CAPACITY MODELS: YGS009-070 (.75 THRU 6 NOMINAL TONS) Due to continuous product improvement, specifications

More information

Product Data. S Two-stage scroll compressor S Variable speed blower motor Control

Product Data. S Two-stage scroll compressor S Variable speed blower motor Control GP Performance Series Geothermal Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.5-4.0 COP, 15.5-24.5 EER (Closed Loop) S 4.0-4.6 COP, 19.6-30.0 EER (Open Loop)

More information

ASTON SERIES COMPACT Commercial Ton Water Source/Geothermal Heat Pump. Submittal Data English Language/IP Units SD1022AGA 05/14

ASTON SERIES COMPACT Commercial Ton Water Source/Geothermal Heat Pump. Submittal Data English Language/IP Units SD1022AGA 05/14 ASTON SERIES COMPACT Commercial 0.75-6 Ton Water Source/Geothermal Heat Pump Submittal Data English Language/IP Units SD1022AGA 05/14 Model Nomenclature 1-2 3 4-6 7 8 9 10 11 12 13 14 GB V 048 T L 0 0

More information

FS Fan-Coil Units Hi-Rise, Vertical

FS Fan-Coil Units Hi-Rise, Vertical FS Fan-Coil Units Hi-Rise, Vertical FSC Concealed Dimensional Data 4-PIPE 2-PIPE TOP VIEWS Page Trims Short (5/8") Here! SIDE VIEW FRONT VIEW Dimensions Unit Size A B Single/Double Supply C D E 03 & 04

More information

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS

More information

CDI series Model TW. Residential Water to Water Heat Pump. Engineering Submittal Sheet. Standard Features. Overview and Certifications

CDI series Model TW. Residential Water to Water Heat Pump. Engineering Submittal Sheet. Standard Features. Overview and Certifications CDI series Model TW Residential to Pump Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options and Control Options Standard Features White Pre-Painted Sheet

More information

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SO TOUGH, WE GUARANTEE IT. SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL SBH SBV www.superiorrex.com SO TOUGH, WE GUARANTEE IT! www.superiorrex.com SBH / SBV Series: CONSTRUCTION FEATURES

More information

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410. PART 1 - GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

DESCRIPTION FEATURES

DESCRIPTION FEATURES SPLIT-SYSTEM AIR COOLED CONDENSING UNIT H5CE150, H5CE180 AND H5CE240 12-1/2, 15 AND 20 NOMINAL TONS (World 50Hz) DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at

More information

Heating and Air Conditioning

Heating and Air Conditioning Heating and Air Conditioning SUBMITTAL SET AFFINITY COMPACT COMMERCIAL GEOTHERMAL/ WATER SOURCE HEAT PUMPS SINGLE AND DUAL CAPACITY MODELS: YKS009-0 (.75 THRU 6 NOMINAL TONS) YKT026-072 (2 THRU 6 NOMINAL

More information

ELITE SERIES R-410A Ready - Multi-Position

ELITE SERIES R-410A Ready - Multi-Position PRODUCT SPECIFICATIONS AIR HANDLERS CBXM ELITE SERIES R-0A Ready - Multi-Position Bulletin No. 0 October 07 Supersedes June 0 Nominal Capacity -. to Tons Optional Electric Heat -. to 0 kw MODEL NUMBER

More information

TVS/R FAN COIL UNITS HI-RISE, VERTICAL

TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVS/R FAN COIL UNITS HI-RISE, VERTICAL TVRM TVRP Riser TVRS TVSE TVSM TVSR TVSS Redefine your comfort zone. www.titus-hvac.com Redefine your comfort zone www.titus-hvac.com Model TVS/R: CONCEALED, HI-RISE

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11. TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed

More information

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS ENGINEERING SPECIFICATIONS NORDIC RH-55-HACW-P-1T-*-SDE*F Horizontal Two-Stage R410a Model Size 55 (Nominal 4 Ton) Reversing (Heating AND Cooling) Domestic Hot Water (desuperheater) 230-1-60VAC Liquid

More information

Product Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control

Product Data. S Two-stage scroll compressor S Variable speed ECM blower motor Control GC Infinityr Series Geothermal Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.8-4.7, 18.5-32.0 EER (Closed Loop) S 4.5-5.2, 23.1-37.0 EER (Open Loop) S Optional

More information

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1.

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1. TECHNICAL SPECIFICATIONS JT4BE Series High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The JT4BE Series of heat pumps offers exceptional performance. The unit, when combined with

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat Producing Quality Heating & Cooling Equipment For Over 50 Years CEA SERIES CEILING EPOSED HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

More information

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018 Replacement Parts List No. 700052400 Revision D 01/2018 Daikin SmartSource Compact Vertical Water Source Heat Pump WGCV 048, 060, 070 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner P7RE 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency self

More information

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor SG-BAH-16 February 2014 Specification Guide B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor Contents Page Product Features

More information

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018 Replacement Parts List No. 700050900 Revision F 04/2018 Daikin Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 072-120 Design 2 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL

RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBV Sales Guide FAN COIL UNITS FLOOR-MOUNTED, VERTICAL RBVS RBVR RBVC www.superiorrex.com RBV Series: LOW POWER CONSUMPTION, ACCESSIBLE AND FLEXIBLE Owners Owners can choose between a standard or elevated

More information

Product Data. S Single-stage scroll compressor S Multi-speed constant torque blower motor Control

Product Data. S Single-stage scroll compressor S Multi-speed constant torque blower motor Control GB Comfort Series Geothermal Heat Pump Sizes 018, 024, 030, 036, 048, 0 Product Data FEATURES & BENEFITS Energy Efficiency S 3.7-4.3 COP, 18.5-21.7 EER (Closed Loop) S 4.3-5.2 COP, 22.7-28.1 EER (Open

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

RCD Air Cooled Condensing Unit (50/60 Hz)

RCD Air Cooled Condensing Unit (50/60 Hz) Environment friendly Easy to access components More efficient air cooled condenser coils Easy to install and maintain The Saudi Factory for Air Conditioning Units RCD Air Cooled Condensing Unit (50/60

More information

Serenity GT Series. Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog.

Serenity GT Series. Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog. Serenity GT Series Two-Stage, R-410a Packaged Horizontal & Vertical Unit Specifi cations Catalog Table of Contents: Product Introduction & Unit Features...2 Performance Data: AHRI - Single Compressor...3

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS 550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS (1100) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H3CE180 & 240 15 AND 20 NOMINAL TONS DESCRIPTION These outdoor condensing units are completely assembled, piped and wired at the factory to provide one-piece

More information

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5 Replacement Parts List No. 700027900 Revision M 09/2018 Daikin McQuay Enfinity Horizontal Water Source Heat Pump WCCH, WCCW 042, 048, 060, 070 Design 5 To find your Daikin Applied parts distributor, call

More information

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS 1 to 40 Nominal Tons Rev-01 TABLE OF CONTENTS Page: Description 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Product Nomenclature Air Cooled Chiller

More information

SECTION AIR TERMINAL UNITS

SECTION AIR TERMINAL UNITS SECTION 23 36 00 AIR TERMINAL UNITS PART 1 - GENERAL 1.1 SUMMARY A. Section includes constant volume terminal units, variable volume terminal units, dual duct terminal units, fan powered terminal units,

More information

Q7RE Series Single Packaged Heat Pump, Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS Q7RE Series Single Packaged Heat Pump, Single Phase 14 SEER, 8.0 HSPF 2 thru 5 Ton Units Cooling: 23,400 to 55,500 Btuh Heating: 21,800 to 56,000 Btuh The Q7 Series single packaged

More information

OmegaAir Series Dedicated Outside Air Systems (DOAS) Engineering Guide

OmegaAir Series Dedicated Outside Air Systems (DOAS) Engineering Guide Series Dedicated Outside Air Systems (DOAS) Engineering Guide Effective September 2017 Vertical and Horizontal Water-Cooled and Air-Cooled Contents Product Features...3 Options...4 Air-Cooled Indoor Ducted

More information

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... 2 Heater Kit Nomenclature... 2 Product Specifications...

More information

Tranquility. Models TRH/V Revised: 18 July, Submittal Data - I-P Units. Performance Data. Electrical Data. Unit Designation: Job Name:

Tranquility. Models TRH/V Revised: 18 July, Submittal Data - I-P Units. Performance Data. Electrical Data. Unit Designation: Job Name: Tranquility High Efficiency () Series Submittal Data Models H/V 006-060 60Hz - HFC-410A English Language/I-P Units Submittal Data - I-P Units Unit Designation: Job Name: Architect: Engineer: Contractor:

More information

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on

More information

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units TECHNICAL SPECIFICATIONS P6SP Series Rev A 6, 7½ and 10 Ton Packaged Electric Cooling Units 11.2 EER Commercial System Units These units are designed specifically for retrofit applications and compatibility

More information

FHP s EnviroSaver the best investment for your environment and home.

FHP s EnviroSaver the best investment for your environment and home. EnviroSaver The two-stage EnviroSaver from FHP provides you with a unit that will suit your budget while incorporating innovative technology for reduced energy costs. FHP was the industry leader in introducing

More information

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil

More information

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz Description These York Latitude packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections

More information

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES (791) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ H1CE180 & 240 15 AND 20 NOMINAL TONS (60 HZ) 13 AND 17-1/2 NOMINAL TONS (50 HZ) SUNLINE 2000 DESCRIPTION These Sunline 2000 units are completely

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS 50Hz Single Package Rooftop, Cooling Only with Puronr (R---410A) Refrigerant One Stage Cooling Capacity Control: Size 07 Two Stage Cooling Capacity Control: Sizes 08, 09, 12 & 14 Submittal Data PERFORMANCE

More information

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RD-A Series Single Packaged Air Conditioner P7RD-A 13 SEER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 56,000 Btuh The P7 Series single packaged air conditioners are high efficiency

More information

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1 Replacement Parts List No. 700029600 Revision L 11/2017 Daikin Daikin McQuay SmartSource Single Stage Vertical Water Source Heat Pump WGSV 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners

More information

Tranquility (TBW) Water-To-Water Series. WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw]

Tranquility (TBW) Water-To-Water Series. WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw] Tranquility () Water-To-Water Series WATER-TO-WATER SYSTEMS SIZES 036, 060, AND 120 [8.7, 13.5 and 26.9 kw] Tranquility Water-To-Water () Series Table of Contents Design Features...4 Unit Model Key...5

More information

Submittal. Front View Side View

Submittal. Front View Side View RBHO Horizontal Low Profile Concealed Free Return Submittal FCU-RBHO-1.0 07-25-18 Top View (Drain Pan Omitted) Bottom View Front View Side View Left hand unit shown. All dimensions are inches [millimeters].

More information

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS JT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The JT4BE Series now offers the choice of a heat pump that uses a more efficient and

More information

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity

ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity TECHNICAL SPECIFICATIONS ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity ET4BE Series now offers the choice of a heat pump that uses a more efficient and environmentally

More information

P7RE Series Single Packaged Air Conditioner

P7RE Series Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner 14 SEER 2 thru 5 Ton Units Cooling: 23,800 to 56,000 BTUH The P7 Series single packaged air conditioners are high efficiency self contained

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PSA4BG Series M1200 Product Line Ultra High Efficiency Air Conditioner 20 SEER Residential System 2-5 Ton Capacities 2 The iq Drive air conditioner system features modulating

More information

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities TECHNICAL SPECIFICATIONS FSH1BG Series Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities The iq Drive heat pump system features modulating compressor technology and variable

More information

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1 Replacement Parts List No. 700024700 Revision M 11/2017 Daikin Daikin McQuay SmartSource Single Stage Horizontal Water Source Heat Pump WGSH 007, 009, 012 Design 1 To find your Daikin Applied parts distributor,

More information

P7RE Series Single Packaged Air Conditioner

P7RE Series Single Packaged Air Conditioner TECHNICAL SPECIFICATIONS P7RE Series Single Packaged Air Conditioner 14 SEER 1½ thru 5 Ton Units Cooling: 17,800 to 56,000 BTUH The P7 Series single packaged air conditioners are high efficiency self contained

More information

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal

More information

AIR COOLED CHILLERS WATER COOLED CHILLERS

AIR COOLED CHILLERS WATER COOLED CHILLERS AIR COOLED CHILLERS WATER COOLED CHILLERS STANDARD UNIT SPECIFICATIONS OF COMMERCIAL AIR COOLED CHILLERS General Description & Assembly Air Cooled Chillers are commercial packaged systems complete with

More information

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker

TSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker HVA9 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208 230 Volt, 1 phase, 60 Hz REFRIGERATION

More information

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

R6GI Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

R6GI Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS R6GI Series Single Packaged Gas/Electric Units 20 SEER 81% AFUE Multi-Stage Cool/Two-Stage Heat 2-5 Ton Single-Phase Units The iq Drive gas/electric packaged system features modulating

More information

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778] FCU-THBP-1.0 08-22-18 THBP Horizontal Low Profile Plenum Return Top View (Drain Pan Omitted) Bottom View Front View Left hand unit shown. All dimensions are inches [millimeters]. Side View Unit Size A

More information

HEAT CONTROLLER, INC.

HEAT CONTROLLER, INC. HEAT CONTROLLER, INC. E N G I N E E R I N G D E S I G N G U I D E HEAT CONTROLLER, INC. 1900 Wellworth Ave., Jackson, Michigan 49203 Ph. 517-787-2100 Fax 517-787-9341 www.heatcontroller.com MODEL NOMENCLATURE

More information

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons Product Catalog NQ Series Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons Page Intentionally Blank Contents Standard Features...1 Available Options...3 Oversized Pumps... 3 High Flow Unit

More information

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016 Replacement Parts List No. 700011300 Revision B 10/2016 McQuay Ceiling Mounted Water Source Heat Pump WCRH, WCRW 030, 036, 042 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787

More information

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY TECHNICAL SPECIFICATIONS VT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The VT4BE Series now offers the choice of a heat pump that uses a more efficient and

More information

R-22, 13 SEER 60 Hertz

R-22, 13 SEER 60 Hertz TECHNICAL GUIDE R-22, 13 SEER 60 Hertz Description These UPG packaged cooling/heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point

More information

McQuay Rooftop Water Source Heat Pumps Catalog 1106

McQuay Rooftop Water Source Heat Pumps Catalog 1106 McQuay Rooftop Water Source Heat Pumps Catalog 06 Model RWA, RGA Downflow Discharge and Return Model, RWC, RGC Horizontal Discharge and Return Unit Sizes 036 R-A Refrigerant Model RWA Engineered for flexibility

More information

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of

More information

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER TECHNICAL SPECIFICATIONS Q6SP Series Rev A 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER Commercial Systems Meet or Exceed ASHRAE 90.1-2010 These 7½ and 10 ton units are designed specifically

More information

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

P5RF Series Rev A Single Packaged Air Conditioner Single Phase TECHNICAL SPECIFICATIONS P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase 15 SEER, 12 EER, R-410A 2 thru 5 Ton Units Cooling: 24,000 to 57,500 Btuh The P5 Series single packaged air conditioners

More information

ELITE Series R-410A - Upflow / Horizontal

ELITE Series R-410A - Upflow / Horizontal PRODUCT SPECIFICATIONS AIR HANDLERS CBX7UH ELITE Series R-0A - Upflow / Horizontal Bulletin No. 08 March 0 Supersedes October 0 Nominal Capacity -. to Tons Optional Electric Heat -. to kw MODEL NUMBER

More information

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION P R O D U C T S P E C I F I C AT I O N S I N D O O R A I R Q U A L I T Y ERV ENERGY RECOVERY VENTILATOR 60 HZ Bulletin No. 20245 March 200 Supersedes April 2009 Indoor / Outdoor 500 to 0,000 cfm Capacity

More information

Tons BTU/h S.E.E.R* E.E.R** HSPF

Tons BTU/h S.E.E.R* E.E.R** HSPF SOUND REFRIGERANT ENVIRONMENTALLY PHD3 Product Specifications 13 SEER, R -410A PACKAGE HEAT PUMP, 2½ to 5 TONS 3 -Phase, 208/230-3 -60 and 460-3 -60 REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS) Product Data UNIT (50 Hz) Single-packaged Heat Pump for Residential and Light Commercial applications. Features/Benefits One-piece

More information