(Direct Expansion Air Handling Unit)
|
|
- Christina Joseph
- 5 years ago
- Views:
Transcription
1 (Direct Expansion Air Handling Unit) ITEM NO. 492X0012
2 Physical Data Physical Data Description Commercial Air-Cooled Condensing Unit Model Packaged 40RR010 Direct Expansion 40RR015 Fan Coil Unit 40RR020 40RR025 40RR030 40RR040 Outdoor Unit 38RGT 38LB-SC Nominal Capacity BTU/Hr (KW) 120,000 (35) 150,000 (44) 200,000 (58) 280,000 (82) 310,000 (90) 388,000 (113) 048S S Model Operating Weight Indoor lb (kg.) Unit 366 (166) 472 (214) 622 (282) 40LAS-X 670 (304) 1114 (505) 1158 (525) Air Quantity Range CFM 2,000-3,400 3,200-5,400 4,400-7,500 5,200-8,600 6,500-10,700 7,800-13,000 Air Flowrate cfm 1,600 2,000 1,600 2,000 2,600 3,200 4,000 5,000 Nominal CFM 3,300 5,300 6,600 8,000 8,600 10,300 kw Cooling Coil Rows...Fins/sq.in Total Face Areasq. ft Hight mm Depth Upper Coil sq. ft. mm Lower Coil sq. ft Suction pipe connection inch 7/8" 7/8" 7/8" 7/8" 1-1/8" 1-1/8" 1-1/8" 1-3/8" Expansion Valve Upper Coil TCLE5HW TCLE5HW TCLE7.5HW TCLE10HW TCLE12HW TCLE15HW Lower Coil TCLE5HW TCLE5HW TCLE7.5HW TCLE10HW TCLE12HW TCLE15HW Coil Face Area sq.ft Fan Coil/ Fin Fan Materail No...Dia. in. Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Cu/Al Shaft Dia. in. 1.0 (25) 1.2 (30) 1.2 (30) 1.2 (30) 1.4 (35) 1.4 (35) Fan Q'ty Speed Range rpm 600-1, , , , , ,000 Motor speed rpm 890/780/ /890/ /780/ /890/ /780/ /780/ /890/ /730/650 Type Standard Speed rpm Permanent split capacitor 839 with internal 845thermal overload Type Synthetic Size Standard Fan Pulley mm B-25 x x B x B x B-30 x x B x B x 1878 Hight Standard Motor Pulley mm 125-1B B B B B B Depth mm Standard Belt...Qty. B B B B B B Type PE Foam Fan Motor Thermal Range Conductivity Hp w/m.k Thickness mm 10 Standard Hp /8" 3/8" 3/8" 3/8" 1/2" 1/2" 5/8" 5/8" Suction pipe connection inch 7/8" 7/8" 7/8" 7/8" 1-1/8" 1-1/8" 1-1/8" 1-3/8" Speed rpm 1,400 1,400 1,430 1,440 1,450 1,450 Condensate drain dia. inch 1/2"MPT 1/2"MPT 1/2"MPT 1/2"MPT 1/2"MPT 1/2"MPT 1/2"MPT 1/2"MPT V/Ph/Hz 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 MPT = Male Pipe Threat Starter Type (Field Supplied) D.O.L. Only D.O.L. or Star-Delta Insulation PE. Foam Thermal Coetificient W/m deg K Thickness in. (mm.) 0.4 (10) Air Nomenclature Filters Factory Supplied No...Size in x20x x25x x25x x25x x20x x25x x25x x20x x25x x25x x20x2 Digit no x20x Connection Model Suction Pipe4 0 L in. A S2x1 1/ x1 4 1/8 X 2x1 3/8 2x1 3/8 2x1 3/8 2x1 3/8 Discharge Pipe in. 2x1/2 2x1/2 2x5/8 2x5/8 2x5/8 2x7/8 Condensate Pipe in. 3/4 3/ /4 1 1/4 Air Handling Unit, 40LAS Series Subbase Field Supplied Factory Supplied Norminal Capacity Cooling Capacity * btu/h 48,000 60,000 48,000 60,000 78,000 98, , ,000 Power input Outdoor Unit (38RGT,38LB Series) Power Supply V/Ph/Hz 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 380/3/50 Dimension Width mm Weight Outdoor Unit kg Pipe Connection Liquid pipe connection inch 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 5/8" 5/8" Indoor Unit (40LAS-X Series) Cooling Coil Coil Arrangement row / fpi 3/14 3/14 3/14 3/14 3/14 3/14 3/14 3/14 Power Supply V/Ph/Hz 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 220/1/50 Fan Fan Size inch 10"x10" 10"x10" 10"x10" 10"x10" 10"x10" 10"x10" 10"x10" 12"x12" Motor Motor Current (RLA) Amp x x x x 4.03 Air Filter Dimension Width mm Weight Indoor Unit kg Insulation Pipe Connection Liquid pipe connection inch Remark : * Shown capacity based on : Ent. Air temp 80Fdb/67Fwb, Max air flowrate. Unit size = 004, 006, 007, 009, 012, 015 X = Direct Expansion Coil 2 Ÿà Õ μ μ Èß ËÕߪ Õ» å 3
3 μ Õß ËÕß 40LAS004 40RS280, 340 Vertical Type 40RS280, 40LAS Horizontal Type Drain 8 Ÿà Õ μ μ Èß ËÕߪ Õ» å 3
4 μ Õß ËÕß 40LAS007 40RS280, 340 Vertical Type Drain 40RS280, 40LAS Horizontal Type Drain 8 Ÿà Õ μ μ Èß ËÕߪ Õ» å 4
5 μ Õß ËÕß 40LAS012 40RS280, 340 Vertical Type Drain 40RS280, 40LAS Horizontal Type Drain 8 Ÿà Õ μ μ Èß ËÕߪ Õ» å 5
6 RECOMENDED SERVICE SPACE B A D C E B (mm.) A B C D E
7 P MINIMUM MINIMUM P / 2 IN INCHES PREFERRED } } OFF RUN Condensate Drain, Draw-Thru Units START UP 7
8 9.5 ( 3/8") ( 1/2") ( 5/8") ( 3/4") A ( - ) ( - ) 9.5 ( 3/8") 24.5 (2.5 kgf.m) 29.4 (3.0 kgf.m) 12.7 ( 1/2") 49.0 (5.0 kgf.m) 53.9 (5.5 kgf.m) 15.9 ( 5/8") 78.0 (8.0 kgf.m) 98.0 (10.0 kgf.m) 19 ( 3/4") (12.0 kgf.m) Sucon line not over 3/4" Bulb Sucon line 7/8" and larger Sucon Line (7/8" and larger) Sucon Line (not over 3/4") Bulb 8
9 9
10 10
11 11
12 WIRING DIAGRAM 40LAS004, LAS007, 009, 012, th Fl, 1858/63-74 Bangna-Trad Road Km. 4.5, Bangna Bnagkok Thailand Tel Fax: LAS-X/06/2015
40LAS-W Series. 40LAS-W Series. 40LAS Series ITEM NO. 492X0013
40LAS-W Series 40LAS-W Series 40LAS Series ITEM NO. 492X0013 Physical Data Description Commercial Air-Cooled Condensing Unit Packaged Chilled Fan Coil Unit Model 40RR010 40RR015 40RR020 40RR025 40RR030
More information42CHS-W Series. Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type. Nominal: 400-2,000 CFM. World's No.1 Air Conditioning Expert QMS 001
42CHS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM QMS 001 World's No.1 Air Conditioning Expert www.carrier.co.th 42CHS-W Series Furred-in ceiling model 400-2000
More information42CLS-W Series Chilled Water Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM
42CLS-W Series Fan Coil Unit Ceiling Concealed - Duct Type Nominal: 400-2,000 CFM World's No.1 Air Conditioning Expert www.carrier.co.th 42CLS-W Series Furred-in ceiling model 400-0 cfm The low silhouette
More informationCHILLED WATER FAN-COIL UNITS
40LM - PRODUCT DATA DIGEST CHILLED WATER FAN-COIL UNITS QUALITY SYSTEM MALAYSIA MS ISO 001 REG. NO: AR 023 1 Any room, every room flexibility in an air conditioning system FEATURES: Chilled Water Furred-in
More informationCeiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary
Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationDECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS
DECORATIVE FAN COIL SPECIFICATIONS UNIT CABINET Single skin or double skin casing (inner perforated sheet or flat sheet) made of powder coated galvanized steel assembled in aluminum extrusion profiles,
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationSINGLE PACKAGE AIR CONDITIONING WATER COOLED
MODELS: CU060-300 5-25 TONS VERTICAL SINGLE PACKAGE AIR CONDITIONING WATER COOLED MODELS: CH060-5-10 TONS HORIZONTAL FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TABLE OF CONTENTS
More informationTECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW
DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW MODELS: D4HH 024 THRU 180 York horizontal ductable air conditioning packages offer a complete line of
More informationR410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2
R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1
More information39L Series. Central Station Air Handlers. Nominal: 2,000-17,750 CFM. World's No.1 Air Conditioning Expert
39L Series Central Station ir Handlers Nominal: 2,000-17,750 CFM World's No.1 ir Conditioning Expert www.carrier.co.th 39L Series Compact, fully-assembled airhandlers combine versatility with economical,
More informationChilled Water FCU. Horizontal Fan Coil 50hz CFM. A Series.
Chilled Water FCU A Series 3-25 CFM Horizontal Fan Coil 5hz www.windind.com CONTENTS GENERAL CONSTRUCTION... 3 MODEL NUMBER NOMENCLA TURE... 4 DIMENSIONS... 5 FAN PERFORMANCE DATA... 7 GENERAL SPECIFICATIONS...
More informationODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz
ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz Condensing Models TTK 060 KD TTA 075 RD TTA 100 RD TTA 120 RD TTA 150 RD TTA 180 RD TTA 200 RD TTA 240 RD Air
More informationA Division of Nailor International Inc. ECONOMY AIR HANDLERS
A Division of Nailor International Inc. MODEL : ECONOMY AIR HANDLERS Thermal Model Standard Specification MODEL 800-4000 CFM AIR HANDLERS Description Model air handlers are designed for efficient and economical
More informationPackage Air Conditioners
MODEL: RACA14 Package Air Conditioners FORM NO. SSC-969 REV. 1 Sure Comfort RACA14 Package Air Conditioners RACA14 14 SEER Nominal Sizes 2-5 Tons [7.0-17.6 kw] Proper sizing and installation of equipment
More informationSection 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH
AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC 80-01 NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH 14 FEATURES MODEL PC 05Z TO PC 30-02 CABINET: Cabinets are constructed of heavily zinc coated galvanized
More informationROOF TOP PACKAGE UNITS
ROOF TOP PACKAGE UNITS HIEER : 3-25 Tons PRODUCT DATA BOOK Introduction Roof Top Package units have been developed & produced to provide not only the ultimate indoor comfort, but also to guarantee long
More informationCFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH
CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH 207 CFFWA NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Universal Mount Fan Coil CFFWA- XX - 1 - U 2-Pipe Heat/Cool
More informationROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh
ROOF TOP (SERIES ) 10.8 TO 103 KW 37,000 TO 351,000 Btuh These rooftop units are complete, self contained air conditioners fully assembled, wire, charged and tested prior to shipment, each unit is delivered
More informationS3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant
TECHNICAL SPECIFICATIONS S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant The S3BN Series of air conditioners offers exceptional performance from
More informationThe World Leading Air-conditioning Company
The World Leading Air-conditioning Company Table of Contents DESCRIPTIONS Model Number Nomenclature Features & Benefits Physical Dimension Fan Performance Curve (4 Row) - 40LMA024 with AC Motor - 40LMA040
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationProduct Data. S Two-stage scroll compressor S Variable speed blower motor Control
GP Performance Series Geothermal Heat Pump Sizes 024, 036, 048, 0, 072 Product Data FEATURES & BENEFITS Energy Efficiency S 3.5-4.0 COP, 15.5-24.5 EER (Closed Loop) S 4.0-4.6 COP, 19.6-30.0 EER (Open Loop)
More informationProduct Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm
Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of
More informationFDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E
R407C TECHNICAL MANUAL Split Systems Air Conditioner Ducted Blower D & E Series FDMP-D, FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E series Cooling only & Heatpump [50Hz] Table of Contents Table of Contents
More informationDESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS
DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS These completely assembled units include a well-insulated cabinet, a DX cooling coil
More informationCHILLED WATER DUCTED FAN COIL
SD CHILLED WATER DUCTED AN A Series B Series (Double Skin) General abricated with a rigid galvanized steel casing. The DIDW centrifugal fans have balanced, galvanized steel, and forward curved blades.
More informationCSA6. Product Specifications. SoftSound SXC 2600
16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVERr COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 2 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland Scroll compressors on all models
More informationDIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS
Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without
More informationLOW STATIC FAN COIL UNITS District Cooling Chilled Water Application
STATIC FAN COIL UNITS District Cooling Chilled Water Application CLASSIFIED INSULATION & FILTER MEDIA GFC LD Series Cooling Capacity Range 9,690 yo 46,064 BTU/HR (4 ROWS ) GFC-LD-TC-10-13 3 General Specifications
More informationMEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS
1 Catalog KM-MCD-0818A Replaces KM-CSA-101A, KM-DSA-101A, KM-MSA-1213A, KM-CSE-101A and KM-MSE-101A DSA, CSA, MSA, CSE, AND MSE SERIES MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS MEDIUM
More informationGPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H
H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...
More informationËÕߪ Õ» ç åé. 50BY/BL Series. Single-Package Cooling Units 90, ,500 BTUH. World's No.1 Air Conditioning Expert
ËÕߪ Õ» ç åé BY/BL Series Single-Package Cooling Units 90,000-895,0 BTUH World's No.1 Air Conditioning Expert www.carrier.co.th BY/BL Series Features Commercial or Industrial Applications Single- or Multiple-Unit
More informationSPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS
550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece
More informationTable of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10
Table of Contents Page No. 1. Model Designation And Unit Models 1 2. Features 2 3. Guide Specifications 4 4. Standard Unit Components 5 5. Technical Data 6 6. Performance Data 10 7. Electrical Data 19
More informationGPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER
Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit
More informationR22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]
R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1
More informationBAC / BHC Product Specifications
COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves
More informationBAC / BHC SERIES 6 to 20 Ton Air Handlers
/ SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design
More informationBAC / BHC SERIES 6 to 20 Ton Air Handlers
/ SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design
More informationPH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C
PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5
More informationMHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil. Heat / Cool Fan Coil 24,000 BTUH. Rev. 1.3
MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Hi-Wall Fan Coil 2-Pipe Nominal Size: 24,000 BTUH Multiaqua Model
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on
More information5 to 100 Ton Capacity Custom Capacities Available
COIL COMPANY 5 to 100 Ton Capacity Custom Capacities Available LRC s remote Air Cooled Fluid Coolers (AFC) provide optimum heat transfer efficiency and are manufactured for years of dependable service.
More informationStandard features. Optional features
FABRIQUÉ AU CANADA MADEIN CANADA Standard features 3/8 inch inner grooved copper tubing up to 5 fan long units. Reduced refrigerant charge with high heat-transfer. Tube sheets with oversized holes and
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:
036-21323-001-B-0202 GENERAL SPECIFICATIONS OUTDOOR UNIT: Two independent refrigerant circuits Inherently protected fan motors Two independent scroll compressors V-Coil Design Exterior service port connections
More informationET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity
TECHNICAL SPECIFICATIONS ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity ET4BE Series now offers the choice of a heat pump that uses a more efficient and environmentally
More informationSUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS
550.23-TG1Y (595) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS H4CE090 & H2CE120 & H1CE150 7-1/2, 10, & 12-1/2 NOMINAL TONS 8.9-9.5 EER SUNLINE 2000 HCE090 208/230/460 VOLT ONLY 208/230/575 VOLT ONLY DESCRIPTION
More informationOmegaAir Series Dedicated Outside Air Systems (DOAS) Engineering Guide
Series Dedicated Outside Air Systems (DOAS) Engineering Guide Effective September 2017 Vertical and Horizontal Water-Cooled and Air-Cooled Contents Product Features...3 Options...4 Air-Cooled Indoor Ducted
More informationFFQN-C, FCRN-E, FFRN-C
R410A TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FCQN-E, FFQN-C, FCRN-E, FFRN-C Cooling only & Heatpump [50Hz] DAIKIN_FFRN.indb i 12/27/2012 9:28:06 AM DAIKIN_FFRN.indb ii
More informationProduct Data. S Single-stage scroll compressor S Multi-speed constant torque blower motor Control
GB Comfort Series Geothermal Heat Pump Sizes 018, 024, 030, 036, 048, 0 Product Data FEATURES & BENEFITS Energy Efficiency S 3.7-4.3 COP, 18.5-21.7 EER (Closed Loop) S 4.3-5.2 COP, 22.7-28.1 EER (Open
More informationSPECIFICATIONS AND DESIGN ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. EDITION 11
AIR HANDLING UNIT (DOUBLE SKIN) MODEL: DS-CW/DX-AHU-H (Chilled Water or Direct Expansion) CAPACITY: 3.3 to 125 Nominal Tons 39,000 to 1,500,000 BtuH 11.4 to 439.5 KW 1,300 to 50,000 CFM Benefits Horizontal
More informationComplete HVAC Capability
Air Handling Units Brochure 1110 January 2006 Complete HVAC Capability MEA Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels Inlet Vane Option
More informationProduct Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons
Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers
More informationCAC SERIES 12-1/2 Thru 20 Ton
CAC SERIES 12-1/2 Thru 20 Ton SPLIT SYSTEM COMMERCIAL AIR CONDITIONER CONSTRUCTION Triple step pre--painted galvanized steal pre--coated inside and out -- using a polyester top coat, over a urethane primer
More informationAPARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS
COMMERCIAL FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS 1½ THRU 3 TONS FEATURES S TXV metering device factory installed
More informationAppendix A. Cooling Coil
Appendix A COILS FOR RUN-AROUND HEAT RECOVERY SYSTEM Cooling Coil Model number D--B45 Coil Information Tag Exhaust Wint Actual airflow Quantity System type 1 Chilled Water Entering dry bulb Entering wet
More informationNew Stylus. Product Catalog. Split System, 1-5 Tons Convertible Type MCX Series 60 Hz MS-PRC015-EN. May 2009
Product Catalog New Stylus Split System, 1-5 Tons Convertible Type MCX Series 60 Hz Cooling Only Cooling with Electric Heat Indoor Units Outdoor Units Outdoor Units Outdoor Units MCX 512 G1 TTK512P1 2TTB0012A1
More informationProduct Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)
Product Data OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A) 5 to 20 Nominal Tons The 50XCR single-package remote aircooled units offer: Compact, durable,
More informationShandong Vicot Air Conditioning Co.,Ltd. Air Cooled Condensing Unit
Air Cooled Condensing Unit PERFORMANCE 10.00 SEER & 13.00 SEER Efficiency Range Cooling capacity from 1.5 to 5 tons T3 Tropical high efficiency Condensing units FEATURES Super quiet top air discharge Sheet
More informationLow Profile Unit Cooler
Low Profile Unit Cooler Publication No. 100.13 January, 2004 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000 BTUH Hot Gas Defrost - 3,600 to 28,000 BTUH Small to Medium Walk -
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9
More informationStandard features. Optional features
FABRIQUÉ AU CANADA MADEIN CANADA Standard features 3/8 inch inner grooved copper tubing up to 5 fan long units. Reduced refrigerant charge with high heat-transfer. Tube sheets with oversized holes and
More informationTSA6. Product Specifications. SmartComfort TXC 5600
ENVIRONMENTALLY SOUND REFRIGERANT TSA6 SmartComfort TXC 5600 Product Specifications 16 SEER SINGLE STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230
More informationLOW HEIGHT UNIT COOLER
Publication No. RU-CTA-0818A Replaces RU-CTA-0712A Ceiling-Temp LOW HEIGHT UNIT COOLER Small to Medium Walk-Ins Cooler and Freezer Applications Air Defrost,00 to 27,00 BTUH Electric Defrost 5,00 to 27,00
More information1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5
TABLE OF CONTENTS 1. Air Handler Features Page 2 2. Physical data Page 3 3. Available kits Page 4 4. Model nomenclature Page 5 5. Air handler blower performance Page 6 6. heating capacity Page 12 7. Maximum
More informationMCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units
MCE4 Electric Heating / Electric Cooling Packaged Thru-the-Wall Units Form No.: MCE4-100 (07/2011) features Up to 10.4 EER cooling efficiency Completely self-contained heating and cooling package No outside
More informationEFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER
ENVIRONMENTALLY SOUND REFRIGERANT HCA7 QuietComfort DXT+ Product Specifications HIGH EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230
More informationi Series Model SV Water Source Heat Pump 1/2 to 6 Ton
i Series Model SV Water Source Heat Pump 1/2 to 6 Ton Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features
More informationTECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS
Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal
More informationCapacity Tables. Cooling Capacity: Cooper&Hunter Wall Mounted FCU
Cooling Capacity: Remark: EWT: Enter Water Temp. ( ); Δt: Temperature Difference ( ) DB: Dry Bulb Temp. ( ); WB: Wet Bulb Temp. ( ); TC: Total Cooling Capacity (kw); SC: Sensible Cooling Capacity (kw);
More informationFan Coil Units POWERED BY KLIMAK ITALY
Fan Coil Units POWERED BY KLIMAK ITALY Index Chilled Water Fan Coil Unit Decorative Fan Coil... Concealed Ducted Fan Coil Unit (Low ESP)...11 Concealed Ducted Fan Coil Unit (Medium ESP)...1 Concealed
More informationMCE4 FEATURES REFRIGERANT SYSTEM CABINET BLOWER CONTROLS INSTALLATION WARRANTY. Electric Heating / Electric Cooling Packaged Units
Electric Heating / Electric Cooling Packaged Units FORM NO. -100 (06/2017) FEATURES Up to 10.0 EER cooling efficiency Less than 2% cabinet air leakage Completely self-contained heating and cooling package
More informationDP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h
DP15H ooling apacity: 23,600-57,500 BTU/h Packaged Air onditioner UP TO 15 SEER 2 to 5 Tons ontents Nomenclature...2 Product Specifications...3 Expanded ooling Data...4 Airflow Data...16 Heater Kit Data...17
More informationProduct Data. 40RUA 18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz
18.3 to 59.2 kw Direct Expansion Packaged Air---Handling Units 50 Hz Product Data 07 --- 12 C09035 Carrier s versatile packaged air-handling units satisfy design requirements with: S Multi-position design
More informationGPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h
Cooling Capacity: 23,000-56,000 BTU/h GPC14M Packaged Air Conditioner 2 through 5 Tons / 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heat
More informationR4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
ENVIRONMENTALLY SOUND REFRIGERANT R4A5 Product Specifications EFFICIENT 14 SEER/11.7 12.2 EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1 phase,
More informationCPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners
CPC Commercial Cooling Capacity: 90,000 118,000 BTU/h 7½- to 12½-Ton Three-Phase Packaged Air Conditioners up to 11.5 EER Standard Features R-410A chlorine-free refrigerant High-efficiency scroll compressor
More informationVT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY
TECHNICAL SPECIFICATIONS VT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The VT4BE Series now offers the choice of a heat pump that uses a more efficient and
More informationPACKAGE HEAT PUMP UNITS
PACKAGE HEAT PUMP UNITS FOM NO. PTZ-77 EV. Supersedes Form No. PTZ-77 ev. 2 Featuring Earth-Friendly -40A efrigerant earth friendly refrigerant TZCHC- SEE HIGH EFFICIENCY SEIES NOMINAL SIZES -5 TONS [0.6-7.6
More informationS5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS
TECHNICAL SPECIFICATIONS S5BP Series Split System Air Conditioner 71/2 Ton Energy Star rated at 11.7 EER and 11.8 IEER 10 Ton rated at 11.2 EER and 11.5 IEER R-410A Refrigerant The S5BP Series of air conditioners
More informationEDN & ESN SERIES PRODUCT DATA BOOK. Capacity: 12,000 to 72,000 BTU/HR CONCEALED DUCTABLE SPLIT SYSTEMS
EDN & ESN SERIES CONCEALED DUCTABLE SPLIT SYSTEMS Capacity: 12,000 to 72,000 BTU/HR CONTENTS Page 1. INTRODUCTION 04 2. SALIENT FEATURES 05 3. G A DRAWINGS 07 4. UNIT SPECIFICATIONS 10 a. ENGINEERING SPECIFICATIONS
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS
550.13-TG11Y (0500) SPLIT-SYSTEM EVAPORATOR BLOWER K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS EER 8.5 DESCRIPTION This completely assembled dual circuit evaporator blower includes a well-insulated
More informationengineering guide Air-Cooled Self-Contained Units
engineering guide Air-Cooled Self-Contained Units FORM 145.00-EG2 (1211) TABLE OF CONTENTS Air-Cooled Self-Contained Units Introduction...............................................................................
More informationTSTAT0201CW (Sold Separately) Qualifying models only. Max. Fuse or Breaker
HVA9 Product Specifications HIGH EFFICIENCY UP TO 19 SEER VARIABLE SPEED AIR CONDITIONER WITH OBSERVER COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208 230 Volt, 1 phase, 60 Hz REFRIGERATION
More informationManufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER
UNHA-T2CA-T3CA-T4CA Universal Air Handler Multi-Zone Only Rev. 1.0 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT
More informationLow Air Process Room. Chiller Series. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW
G4 Low Air Process Room Chiller Series EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW DEPC - High & Medium Temperature Application Dual Air Throw Capacity: 4.4kW to 38.4kW Low Noise
More informationAPARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS
FSA Product Specifications APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS 1½ THRU 3 TONS FEATURES TXV metering device factory installed
More informationHCH6. Product Specifications
HCH6 Product Specifications HIGH EFFICIENCY 16 SEER TWO- STAGE HEAT PUMP WITH OBSERVERt COMMUNICATING CONTROL SYSTEM 2 THRU 5 TONS SPLIT SYSTEM 208/230 Volt, 1- phase, 60 Hz REFRIGERATION CIRCUIT S Copeland
More information48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH
48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled or Hot Water with Optional Electric Heat Multi-Position
More informationGPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h
H Packaged Heat Pump ooling apacity: 24,000-57,500 BTU/h Heating apacity: 22,000-54,500 BTU/h 13 SEER / R-410A 2 to 5 Tons Standard Features Energy-efficient compressor with internal relief valve PS blower
More information6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH
CAE Product Specifications 6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant REFRIGERATION CIRCUIT Copeland scroll compressors on all models with single refrigeration
More informationProduct Catalogue. Large Commercial Split System. Split System Tons RAUP/TTV Models 50 Hz. August 2005 SSA5-PRC003-EN
Product Catalogue Large Commercial Split System Split System 23-55 Tons RAUP/TTV Models 50 Hz August 2005 SSA5-PRC003-EN 2 American Standard Inc. 2005 SSA5-PRC 003-EN Contents Model Number Description
More informationCAT PAU 99(2) SUPERSEDES CAT.NO SARAVEL PACKAGED AIR CONDITIONING UNITS
CAT PAU 99(2) SUPERSEDES CAT.NO.200-95 SARAVEL PACKAGED AIR CONDITIONING UNITS TABLE OF CONTENTS Introduction...3 Physical Data..... 4 Selection Procedure....5-7 Water Cooled Packaged Unit Ratings....
More informationMGE4 FEATURES REFRIGERANT SYSTEM HEAT EXCHANGER CABINET BLOWER
GAS HEATING / ELECTRIC COOLING PACKAGED UNITS FORM NO. -100 (07/2017) FEATURES Up to 10.0 EER cooling efficiency Less than 2% cabinet air leakage Completely self-contained heating and cooling package No
More informationBHH Product Specifications
BHH Product Specifications HORIZONTAL BELT DRIVE DIRECT EXPANSION BLOWER COIL UNITS ALL S 3, 4, and 5 Ton 208/230 3 60 and 460 3 60 supply voltage Units are ETL listed to U.S. and Canadian safety standards
More informationR4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT
R4A4 Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1 1/2 THRU 5 TONS SPLIT SYSTEM 208/2 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT Scroll compressors
More informationREFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils
MHP4 Electric Heat Pump Packaged Thru-the-Wall Units FEATURES Up to 10.4 EER cooling efficiency Completely self-contained heating and cooling package No outside condensing unit No external refrigerant
More informationVWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ
PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three
More information