Ex eb IIC Gb Ex ia IIC Ga Ex Tb IIIC Db DRILLING AND ASSEMBLY OF JBEP JUNCTION BOXES AND ENCLOSURES GUIDE
|
|
- Magdalene Moore
- 6 years ago
- Views:
Transcription
1 Ex eb IIC Gb Ex ia IIC Ga Ex Tb IIIC Db DRILLING AND ASSEMBLY OF JBEP JUNCTION BOXES AND ENCLOSURES GUIDE
2 To easily accommodate your unique application requirements and maintain compliance with certification requirements, Appleton/ATX offers you the ability to drill and equip junction boxes for Increased Safety and dust protection environments in the field. Appleton/ATX provides the following solutions: Standard pre-drilled or tapped and equipped junction boxes ready for use; see the Appleton/ATX catalog. Junction boxes pre-drilled or tapped and equipped by Appleton/ATX in accordance with customer requirements. Junction boxes drilled or tapped and equipped by customer, using this guide. By following the instructions in this Appleton/ATX guide, you can ensure compliance with the relevant standards for the self-arrangement of junction boxes. The installation standard IEC stipulates: Article : additional cable entries can be installed in the enclosures in accordance with the manufacturer documentation that so allows. Article 15.1: maximum dissipated power of the terminal boxes to comply with the temperature class. It can be reached by complying with either: - Point d: the number of authorized terminals, conductor cross-section and maximum current supplied by the manufacturer, or - Point e: the calculation parameters supplied by the manufacturer. The calculated value must be lower than nominal maximum dissipated power.
3 CATALOG NUMBERING GUIDE 2 JBEP Series Undrilled and Predrilled, Empty Fiberglass Reinforced Polyester Junction Boxes JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Electrical and Power Applications STEP 1: Understand General Information and Intrinsic Safety 5 STEP 2: Define the Number of Terminals 7 STEP 3: Calculate Dissipated Power Using Per Terminal Current Ratio Method 12 STEP 4: Calculate Dissipated Power Using Per Current Circuit Needs 15 STEP 5: Define the Number of Cable Entries 16 STEP 6: Location of Cable Entries 17 STEP 7: Complete The Drilling 21 STEP 8: Ensure Appleton/ATX Requirements 22
4 CATALOG NUMBERING GUIDE JBEP SERIES UNDRILLED AND PREDRILLED, EMPTY FIBERGLASS REINFORCED POLYESTER JUNCTION BOXES Increased Safety. For Field Drilling and Customization Applications Designed for Zone 1 or 2 locations where flammable gases or vapors are present either continuously, often or accidentally such as: Petroleum Chemical Refineries Other industrial process facilities Ideal for indoor/outdoor use with wet or corrosive atmospheres. Designed for use in Zone 21 or 22 locations where flammable dusts (conductive and non-conductive) are present either continuously, often or accidentally such as: Food processing Dairy Brewing Other industrial process facilities Designed for Zone 0 and Zone 20 Intrinsically Safe applications when used with rated terminals. JBE P G Series: JBE - Junction Box ATEX/IECEx Certified Dimensions Height mm (in): (3.35) (4.72) (6.69) (7.87) (9.84) (12.60) (19.69) (29.53) Dimensions Depth mm (in): (2.36) (2.60) (3.58) 09S - 91 (3.58) (3.74) (5.91) (9.06) Options: (Options must be listed alphabetically) A - Earth Continuity Brass Plate G - Cable Glands M - Mounting Pan H - Hinges for Sizes 500 or 750 x 320 x 150 or 230 mm (19.69 or x 9.06 x 5.91 or 9.06 ) HR - Horizontal DIN-Rail VR - Vertical DIN-Rail # - Customized at Factory Material: P - Polyester Dimensions Width mm (in): (3.35) (4.72) (6.69) (8.47) (9.84) (12.60) (19.69) (29.53) Gland Plates: 0 - No Gland Plate 1 - Bottom, Plastic 2 - Top and Bottom, Plastic 3 - Bottom and Sides, Plastic 4 - All Sides Plastic, 5 - Bottom, Brass 6 - Top and Bottom, Brass 7 - Bottom and Sides, Brass 8 - All Sides, Brass 2
5 CATALOG NUMBERING GUIDE JBEP SERIES FIBERGLASS REINFORCED POLYESTER TERMINAL JUNCTION BOXES FOR INSTRUMENTATION APPLICATIONS Increased Safety. Factory Drilled and Equipped Applications Instrumentation junction boxes are used to run process or remote information to control room. For use in intrinsic safety or non intrinsic safety systems. Designed for Zone 1 or 2 locations where flammable gases or vapors are present either continuously, often or accidentally such as: Petroleum Chemical Refineries Other industrial process facilities Ideal for indoor/outdoor use with wet or corrosive atmospheres. Designed for use in Zone 21 or 22 locations where flammables dusts (conductive and non-conductive) are present either continuously, often or accidentally such as: Food processing Dairy Brewing Other industrial process facilities Designed for Zone 0 and Zone 20 Intrinsically Safe applications when used with rated terminals. JBE P A I 01 D Series: JBE - Junction Box ATEX/IECEx Certified Dimensions Height mm (in): (6.69) (7.87) (8.47) (9.84) (12.60) (19.69) (29.53) Dimensions Depth mm (in): (3.58) (5.91) (9.06) Options: I - Instrumentation Options: D - Drain Material: P - Polyester Dimensions Width mm (in): (6.69) (8.47) (9.84) (12.60) (19.69) (29.53) Cable Type: A - Armored N - Non-Armored L - Armored Lead Sheathed Suffix: 01 to 99 Assigned to Factory 3
6 CATALOG NUMBERING GUIDE JBEP SERIES FIBERGLASS REINFORCED POLYESTER TERMINAL JUNCTION BOXES FOR ELECTRICAL AND POWER APPLICATIONS Increased Safety. Factory Drilled and Equipped Applications Electrical junction boxes are used to distribute power to lighting and to the other power and control circuits. Power junction boxes are used to connect cables together to supply main lighting circuits, motors, service receptacles and other equipment. Designed for Zone 1 or 2 locations where flammable gases or vapors are present either continuously, often or accidentally such as: Petroleum Chemical Refineries Other industrial process facilities Ideal for indoor/outdoor use with wet or corrosive atmospheres. Designed for use in Zone 21 or 22 locations where flammables dusts (conductive and non-conductive) are present either continuously, often or accidentally such as: Food processing Dairy Brewing Other industrial process facilities Designed for Zone 0 and Zone 20 Intrinsically Safe applications when used with rated terminals. JBE P A E 01 T Series: JBE - Junction Box ATEX/IECEx Certified Dimensions Height mm (in): (3.35) (4.72) (6.69) (7.87) (9.84) (12.60) (19.69) (29.53) Dimensions Depth mm (in): (2.36) (3.58) 09S - 91 (3.58) (3.74) (5.91) (9.06) Options: (Options must be listed alphabetically) E - Electrical: 2.5 mm 2 (14AWG) x 10 mm 2 (6AWG) P - Power: 16 mm 2 (6AWG) to 240 mm 2 (474MCM) Other Suffix: T - Mantle Clamping (Pillar Terminals) Material: P - Polyester Dimensions Width mm (in): (3.35) (4.72) (6.69) (8.47) (9.84) (12.60) (19.69) (29.53) Cable Type: A - Armored N - Non-Armored Suffix: 01 to 99 Assigned to Factory 4
7 STEP 1: GENERAL INFORMATION To make your choice easy, Appleton/ATX suggests a method that takes all parameters into account, including connecting cross-sections, current carrying capacity of terminals, the number of cable entries, and the requirements of European standards. To determine the useful height of the enclosure, a minimum distance has to be maintained between the inside surface of the enclosure and the connection point of the terminals so that conductors with comply with the specified bending radii. The tables below show the minimum distances to be maintained as a function of connection cross-sections. Values of B1 can be less than B2 because the wires can be routed in three dimensions (conductor can be passed under the rails). Dimension C should be used when cable entries are located in the lower part of the enclosure. For applications where cross-through wiring is employed, the value of C should be equal to A. VERTICAL ENCLOSURE MOUNTING Chassis Mounting Minimum Useful Height : T1 (mm) Terminals (mm 2 ) Quantity of Rails Back Plate Mounting Minimum Useful Height : T2 (mm) Terminals (mm 2 ) Quantity of Rails Minimum Dimensions (mm) A B B C D Vertical Chassis Mounting C D B1 T1 D A Vertical Back Plate Mounting C D B2 T2 D A Horizontal Chassis Mounting A D B1 D C HORIZONTAL ENCLOSURE MOUNTING Chassis Mounting Minimum Useful Height : T1 (mm) Terminals (mm 2 ) Quantity of Rails Back Plate Mounting Minimum Useful Height : T2 (mm) Terminals (mm 2 ) Quantity of Rails Minimum Dimensions (mm) A B B C D Terminal Dimensions from Weidmüller Interface GmbH & Co. KG WDU Type T1 Horizontal Back Plate Mounting A D B2 D C T2 5
8 STEP 1: GENERAL INFORMATION INTRINSIC SAFETY [IS] Intrinsic safety is a protection technique for safe operation of electrical equipment in hazardous areas by limiting the energy available for ignition. Intrinsically safe enclosures require a minimum of IP20 protection. Rules for combining IS terminals with e terminals: a) Terminal Color When there is a risk of confusion between several types of terminals inside the enclosure, IS terminals must be identified with a light blue color. Terminals that conform to EN/IEC can be used for IS circuits connection b) Clearance Distances Clearance distances between IS and NIS (non-intrinsically safe) terminals. X = the partition. If the partition is metallic, it must be grounded/earthed. Without Partition With Partition IS 50 mm 50 mm IS X NIS NIS c) Creepage Distances. 3 mm clearance from metallic parts (rails, walls, etc.) 6 mm clearance between two terminals with different polarity 3 mm 3 mm 3 mm 5 mm IS NIS d) IS Component Markings IS components are marked with rectangular brackets [ia] Zone 0 or [ib] Zone 1. These [IS] components are associated materials that cannot be installed in Ex eb enclosures. However, they can be installed in flameproof enclosures. Rules for Combining IS Terminals With e Terminals: In order to satisfy the requirements of European standards EN/IEC and EN/IEC , Ex eb IIC enclosures should be used to comply with the maximum certified dissipation power (Pw) of respective enclosures. The dissipated power of the enclosure is calculated by: 1. A given temperature class 2. Maximum allowable number of terminals per each enclosure 3. Number of cross-connections 4. Current carrying capacity of each circuit 5. Dissipated power of internal wiring ATEX certified terminals from different manufacturers can be used, provided electrical data (rated voltage and current) is within conformance. 6
9 STEP 2: DEFINE THE NUMBER OF TERMINALS II2G and EPL.Gb II2D and EPL.Db Internal Dimensions (mm) Catalog Number H W D JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP VERTICAL ENCLOSURE MOUNTING Maximum Allowed Dissipated Power (Watt) Maximum Available Length L (mm) II2G and EPL.Gb II2D and EPL.Db Internal Dimensions (mm) Catalog Number H W D JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP L 7
10 STEP 2: DEFINE THE NUMBER OF TERMINALS HORIZONTAL ENCLOSURE MOUNTING Maximum Allowed Dissipated Power (Watt) Maximum Available Length L (mm) II2G and EPL.Gb II2D and EPL.Db Internal Dimensions (mm) Catalog Number H W D JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP L The total length of the terminal block must not exceed the dimension L. Terminal Size (mm 2 ) Pitch (mm) Cable Size (mm 2 ) Maximum Current (Amp) L Temperature Classes T6 for Ta +40 C and T5 for +40 C < Ta +55 C (T6 for Ta F and T5 for F < Ta +131 F) 8
11 STEP 2: DEFINE THE NUMBER OF TERMINALS MAXIMUM NUMBER OF DIN-RAILS IN BACK PLATE MOUNTING AND CHASSIS MOUNTING VERTICAL ENCLOSURE MOUNTING Catalog Number Maximum Number of DIN Rails Terminals (mm 2 ) JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP HORIZONTAL ENCLOSURE MOUNTING Catalog Number Maximum Number of DIN Rails Terminals (mm 2 ) JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP
12 STEP 2: DEFINE THE NUMBER OF TERMINALS MAXIMUM NUMBER OF TERMINAL BLOCKS IN CHASSIS MOUNTED ENCLOSURES VERTICAL ENCLOSURE MOUNTING Catalog Number Maximum Current (Amp) Maximum Number of Terminal Blocks (Chassis Mounting) Terminal Size (mm 2 ) JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP HORIZONTAL ENCLOSURE MOUNTING Catalog Number Maximum Current (Amp) Maximum Number of Terminal Blocks (Chassis Mounting) Terminal Size (mm 2 ) JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP
13 STEP 2: DEFINE THE NUMBER OF TERMINALS MAXIMUM NUMBER OF TERMINAL BLOCKS IN BACK PLATE MOUNTED ENCLOSURES VERTICAL ENCLOSURE MOUNTING Catalog Number Maximum Current (Amp) Maximum Number of Terminal Blocks (Back Plate Mounting) Terminal Size (mm 2 ) JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP HORIZONTAL ENCLOSURE MOUNTING Catalog Number Maximum Current (Amp) Maximum Number of Terminal Blocks (Back Plate Mounting) Terminal Size (mm 2 ) JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP
14 STEP 3: CALCULATE DISSIPATED POWER USING PER TERMINAL CURRENT RATIO METHOD P(W) = Total dissipated power of the junction box (Watts). P(W) = [ N x P1 ] + [ N x P1 ] + [ N x P1 ] + [ N x P1 ] 2.5 mm 2 4 mm 2 6 mm mm 2 Terminal Terminal Terminal Terminal N = Number of same cross-section terminals P1(W) = Dissipated power of terminal and cable Use the table below to check if the calculated power P(W) is less than or equal to maximum allows dissipated power in the junction box. Maximum Allowed Dissipated Power P(W) Maximum Available Length L (mm) II2G and EPL.Gb II2D and EPL.Db Internal Dimensions (mm) Catalog Number H W D JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP
15 STEP 3: CALCULATE DISSIPATED POWER USING PER TERMINAL CURRENT RATIO METHOD I(A) = 100% of Maximum Current (Amp) Catalog Number Dissipated Power P1 (Watts) Terminal Size (mm 2 ) I(A) JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP I(A) = 80% of Maximum Current (Amp) Catalog Number Dissipated Power P1 (Watts) Terminal Size (mm 2 ) I(A) JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP
16 STEP 3: CALCULATE DISSIPATED POWER USING PER TERMINAL CURRENT RATIO METHOD I(A) = 50% of Maximum Current (Amp) Catalog Number Dissipated Power P1 (Watts) Terminal Size (mm 2 ) I(A) JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP I(A) = 25% of Maximum Current (Amp) Catalog Number Dissipated Power P1 (Watts) Terminal Size (mm 2 ) I(A) JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP
17 STEP 4: CALCULATE DISSIPATED POWER USING PER CURRENT CIRCUIT NEEDS P(W) = Total dissipated power of the enclosure (Watts). P = N1 x P1 + N2 x P2 + N3 x P3 + Nn x Pn N1, N2, N3, Nn = Number of terminals with different cross-sections. Example: N1 = total number of 2.5 mm 2 terminals inside an enclosure; N2 = total number of 4 mm 2 terminals ). P1, P2, P3, Pn= Dissipated power of terminal and cable with different cross-sections. Example: P1 = Dissipated power of 2.5 mm 2 terminal and cables inside an enclosure; P2 = Dissipated power of 4 mm 2 terminals Note: P1, P2, P3, Pn is equal to dissipated power of a specific sized terminal (Pb). Use the table below Pb = Terminal Dissipated Power to calculate Pb plus (+) dissipated power of the cable connected to the same sized terminals (Pc). Example: P1 = Pb + Pc. Terminal (mm 2 ) Pb (Watts) Pc = R x I 2. (Pc) dissipated power of the cable connected to the same sized terminals = (R) the resistance of the cable (ohms). Use the table below R = Resistance of the cable (ohms) x (I) Current intensity (Amp) refer to STEP 3 Dissipated Power Per Current Ratio. Catalog Number R: Resistance of the Cable (ohms) Considering +80 C (176 F) on Insulation Sheath Terminal (Cross-Section mm 2 ) JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP Check if the Calculated Power P is Less Than or Equal to Maximum Allowed Dissipated Power of the Box. Maximum Allowed Dissipated Power (W) Maximum Available Length L (mm) II2G and EPL.Gb II2D and EPL.Db Internal dimensions (mm) Catalog Number H W D JBEP JBEP JBEP JBEP121209S JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP JBEP
18 STEP 5: DEFINE THE NUMBER OF CABLE ENTRIES Selection of enclosure based on size and number of cable entries: The table below identifies the number and size of cable entries permitted. Example: Enclosure catalog number JBEP121209S Side A: the largest cable entry is one M40 per side or JBEP Side A: the largest cable entry is two M40 per side. Cable Entry Metric Thread Number of Cable Entries Side A M20 1 M25 1 M32 1 M40 2 M50 3 Drain M20 1 Side D Side C Side B Allowable Number of Cable Entries Per Side Allowable Maximum Internal Dimensions (mm) II2G and EPL.Gb II2D and EPL.Db A B C D Size H W D Catalog Number M JBEP M JBEP M JBEP M JBEP121209S M JBEP M JBEP M JBEP M JBEP M JBEEP M JBEP M JBEP M JBEP M JBEP M JBEP M JBEP
19 STEP 6: LOCATION OF CABLE ENTRIES The drawings below show where cable entries can be located. The available space for cable entry locations is shown within the dotted lines. Dimensions are shown in millimeters. JBEP JBEP JBEP JBEP121209S JBEP
20 STEP 6: LOCATION OF CABLE ENTRIES The drawings below show where cable entries can be located. The available space for cable entry locations is shown within the dotted lines. Dimensions are shown in millimeters. JBEP JBEP JBEP JBEP
21 STEP 6: LOCATION OF CABLE ENTRIES The drawings below show where cable entries can be located. The available space for cable entry locations is shown within the dotted lines. Dimensions are shown in millimeters. JBEP JBEP JBEP
22 STEP 6: LOCATION OF CABLE ENTRIES The drawings below show where cable entries can be located. The available space for cable entry locations is shown within the dotted lines. Dimensions are shown in millimeters. JBEP JBEP
23 STEP 7: COMPLETE THE DRILLING Drilling Dimensions and Assembly Layout for EEXe Series Polyamide Cable Glands B D A C C Metric Thread Installation Dimensions Dimension Across Flats (A/F) Internal Drilling Dimensions for Fixing Cable Entries Thread Dimensions A B C D Minimum Maximum Pitch (mm) Nominal Diameter M20S M M25S M M M M50S M M63S M M75S M M M Catalog Number E1FX / E2FX, E1FW / E2FW, and T3 The Drilling Distances are Designed to Comply with a Minimum 3mm Clearance 3 3 For use with other cable glands, installation dimensions must be modified as below: A = (A/F) x B = A x
24 STEP 8: ENSURE APPLETON/ATX REQUIREMENTS Appleton/ATX s requirements to ensure the IP Rating of your enclosure. DRILLING AND MACHINING CAUTION! Code does not permit an enclosure to have tapped holes and an earthing plate on a single enclosure in the same location. CAUTION! Cable entry sizes M40 and larger must be fastened to the enclosure using a clearance hole and locknut. Earthing plate performs three functions: 1. Provides earth continuity. 2. When used with armored cable, it provides proper grounding for the cable armor. 3. Mechanically holds the cable glands in position. Equip polyester enclosures with an earthing plate for electrical continuity of cable armor. Depending on the thickness of the earthing plate, you can make a combination of clearance holes and/or tapped holes in the earthing plate. Catalog Number Thickness (mm) JBEP JBEP JBEP JBEP121209S 4.5 JBEP JBEP JBEP JBEP JBEEP JBEP JBEP JBEP JBEP JBEP JBEP (Wall thickness) LOCKNUTS FOR TAPPED AND CLEARANCE HOLES CAUTION! Do not forget the locknuts. Catalog Number Thread A B C M M M M M
25 STEP 8: ENSURE APPLETON/ATX REQUIREMENTS Appleton/ATX s requirements to ensure the IP Rating of your enclosure. Proper drilling must done in order to maintain the Ingress Protection (IP) Rating of the assembly. Cable entries must be drilled perpendicular to the surface of the enclosure to prevent bending and stressing of the enclosure walls. Clearance Hole Dimensions Example of Cable Entries Size Drilling Ø (+0.2/-0.4) Correct Incorrect M M M M Clearance Hole M M M M90 91 M Tapped Hole Earth Stud Mounting of feed-thru earth/ground terminal. Marking Mounting of the label in order to maintain the enclosure's Ingress Protection (IP) Rating. SILICON O-RING STAINLESS STEEL HEXAGONAL JAM NUT WALL OF THE ENCLOSURE WALL OF THE ENCLOSURE THRUST WASHER STAINLESS STEEL SPRING LOCK WASHER STAINLESS STEEL FLAT WASHER STAINLEES STEEL THREADED ROD M6 TO M12 LABEL(* ) * SMOOTH HOLES DRILLED ON THE LAB AND ON THE COVER NUT LOCK WASHER SEALING WASHER (ELASTOMER ) Traceability All Appleton/ATX equipment is marked with a catalog number that corresponds to the product supplied, in accordance with article 29.2 in Standard EN/IEC Note that the manufacturing number may be the same for a series of identical equipment, coming from same batch. For self-customized enclosures, a label containing at least your name and manufacturing number should be placed near the Appleton/ATX label for purposes of product traceability. Depending on the size of the enclosure, the size of the self-customized enclosures label will vary. 23
26 Appleton is our premium line of industrial electrical products under Appleton Group, a business unit of Emerson. Emerson brings integrated manufacturing solutions to diverse industries worldwide. Our comprehensive product line, extensive experience, world-class engineering and global presence enable us to implement solutions that give our customers the competitive edge. For over 150 years, our electrical product brands have been providing a rich tradition of long-term, practical, high quality solutions with applications ranging from the construction and safe operation of petrochemical and process plants to providing quality power that precisely controls automotive robotic production. Engineers, distributors, contractors, electricians and site maintenance professionals around the world trust Emerson Industrial Automation brands to make electrical installations safer, more productive and more reliable. Appleton Group is organized into three focused businesses that provide distributors and end-users expert knowledge and excellent service. Electrical Construction Materials This group is made up of the Appleton and O-Z/Gedney brands. They manufacture a broad range of electrical products including conduit and cable fittings, plugs and receptacles, enclosures and controls, conduit bodies and industrial and hazardous lighting. Whether the application is hazardous location, industrial or commercial, the electrical construction materials group has the products to meet your needs. Power Quality Solutions The SolaHD brand offers the broadest power quality line, including uninterruptible power supplies, power conditioners, voltage regulators, shielded transformers, surge protection devices and power supplies. Heating Cable Systems This group is made up of the EasyHeat and Nelson brands. They offer a broad range of electrical heating cable products for residential, commercial and industrial applications. Asia/Pacific Australia Canada China Europe Mexico/Latin America Middle East/Africa/India United States Appleton Grp LLC 9377 W. Higgins Road Rosemont, IL appletonelec.com Connect with Appleton Facebook Twitter YouTube Appleton Grp LLC d/b/a Appleton Group. The Appleton logo is registered in the U.S. Patent and Trademark Office. EasyHeat, Inc. is a wholly owned subsidiary of Appleton Grp LLC. All other product or service names are the property of their registered owners. 2015, Appleton Grp LLC. All rights reserved.
JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped
Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Location Outlet Boxes Applications Instrumentation junction boxes are used to run process or remote information to control room. For
More informationEXPLOSIONPROOF PROTECTION SIMPLIFIED PLEXPOWER LIGHTING AND POWER PANELBOARDS
EXPLOSIONPROOF PROTECTION SIMPLIFIED PLEXPOWER LIGHTING AND POWER PANELBOARDS EASY TO INSTALL, OPERATE AND MAINTAIN. PlexPower Panelboards use circuit breaker modules that provide explosionproof protection
More informationVERSATILE, DIRECT-MOUNT POWER FOR EXTREME ENVIRONMENTS IP67 SCP-X POWER SUPPLIES CLASS 2 LISTED
VERSATILE, DIRECT-MOUNT POWER FOR EXTREME ENVIRONMENTS IP67 SCP-X POWER SUPPLIES CLASS 2 LISTED SIMPLE VERSATILITY. RELIABLE PERFORMANCE. SUBSTANTIAL SAVINGS. SolaHD IP67 SCP-X power supplies mount directly
More informationdin rail mounted active tracking filters with surge protection Product Guide DIN RAIL MOUNTED INDUSTRIAL DC UPS Product Guide
din rail mounted active tracking filters with surge protection Product Guide DIN RAIL MOUNTED INDUSTRIAL DC UPS Product Guide SDU DIN RAIL DC UPS From the industry leader in power quality solutions comes
More informationDIN RAIL MOUNTED INDUSTRIAL DC UPS OPTIMIZING UPTIME.
DIN RAIL MOUNTED INDUSTRIAL DC UPS OPTIMIZING UPTIME. PROTECT SENSITIVE COMPUTER AND MANUFACTURING OPERATIONS WITH AN UNINTERRUPTiBLE DC POWER SUPPLY. The SDU DIN Rail DC UPS is the only choice for the
More informationP SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE
P SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE A BREAKER PROTECTION BREAKTHROUGH Simplify flameproof protection for lighting, heat trace and power circuit distribution with the new generation
More informationCertified to Protect. Built to Endure.
AX HEAT TRACE CONNECTION KITS Certified to Protect. Built to Endure. Connect Heat Trace Cables Safely and Securely in Harsh and Hazardous Locations. Nelson AX Connection Kits provide robust, weatherproof,
More informationPOWERPLEX PANELBOARD 1
1 POWERPLEX PANELBOARD 2 ADVANCING PANELBOARD TECHNOLOGY WITH COMPONENT LEVEL PROTECTION. Introducing the PowerPlex Panelboard. Appleton's PowerPlex Panelboard changes the face of hazardous location panelboards
More informationPLEXPOWER LIGHTING AND POWER PANELBOARDS PRODUCT GUIDE
PLEXPOWER LIGHTING AND POWER PANELBOARDS PRODUCT GUIDE EASY TO INSTALL, OPERATE AND MAINTAIN. PlexPower Panelboards use circuit breaker modules that provide explosionproof protection for standard off-the-shelf
More informationJunction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety
JBES Series Medium Voltage 11 kv ECES Series Compliance Data: ATEX - IEC: ATEX IEC CE Ex e II Ex ia IIC; Ex ib IIC T6 to T4 Ex td A21 T80 C to T130 C Ex de IIC; Ex demb IIC Operating Temperatures: -50
More informationHKH Series. HAZCON Controls for Harsh and Hazardous Environments
HKH Series HAZCON Controls for Harsh and Hazardous Environments Z A H LO C NON-METALLIC DIN RAIL MOUNT Component Mounting Rail Optional Customer I.D. Nameplate Optional Legend Plate Explosion Protective
More informationIECEx Certificate of Conformity
Certificate of Conformity: IECEx BAS 07.0033X http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/9e9052... Page 1 of 4 18/06/2008 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL
More informationSTAINLESS STEEL PANEL MOUNT
Z A H LO C STAINLESS STEEL PANEL MOUNT Optional Legend Plate Cover Screw Retaining Washer Panel Mount Bracket Explosion Protective LED Pilot Light Stainless Steel Washer Actuator Spacer Locknut Explosion
More informationTerminal Boxes in Stainless Steel SLS**.T
Features Variant options Stainless steel enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 6 enclosure size options Various terminal and cable gland configurations
More informationHKH Series. HAZCON Controls for Harsh and Hazardous Environments
(93) A ø 0.2" (ø 5.5) 1.9 (4 3.7" (93) B A " 0) 8" 0) HKH Series HAZCON Controls for Harsh and Hazardous Environments 0.2" (5.5) 0.2" (5.5) 3.1" (80) 2.8" (70) ø 0.2" (ø 5.5) 1.9" (48) 3.7" (93) A B 0.2"
More informationEx e, ia Junction boxes TNCN. Features
TNCN Features The TNCN/TNCC range comprises many standard sizes of enclosure manufactured in 316L acid resistant stainless steel to give the maximum environmental protection. The main body is manufactured
More informationNew products Ex Equipment 2015
New products Ex Equipment 2015 ROSE Systemtechnik GmbH ROSE Systemtechnik GmbH was founded in Porta Westfalica, Germany, in 199 and is today one of the world s leading and innovative providers of industrial
More informationATX PRE Series 63 Amp Plugs and Sockets Increased Safety
ATX PRE Series 63 Amp s and Sockets Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator
More informationATX DPD Series Distribution Panelboards Flameproof
ATX DPD Series Distribution Panelboards Applications Protection and control of electrical equipment in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation
More informationTERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS
OSUR CL HA ES EN KILLARK Z LO C SJIC SERIES TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS Screw cover style, with or without continuous hinge 3/16 (5mm) wide flat flange for maximum gasket surface
More informationCCAI, CCAIF, CCAIF..H
CCAI, CCAIF, CCAIF..H - Zone 1, 2, 21, 22 - Group IIC - Stainless steel junction boxes - Choice of 4 sizes - IP66 AISI 316L stainless steel Grub screws for opening lid Lid opening system Detail of inside
More informationUnicode 2 Series Pre-Drilled Control Stations Increased Safety Polyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum
Unicode 2 Series Pre-Drilled Control Stations Polyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum, Type 4X ; Type 4X Applications Local control stations and motor control stations
More informationATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationPRE Series 63 Amp Plugs and Sockets Increased Safety
Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator sets Air conditionings Compressors
More informationATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22
Applications Can be installed in hazardous areas designated as Zone 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection against
More informationM-0. M-0... series control, monitoring and signalling devices. Ex e
M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere
More informationTerminal Boxes TNCN. Explosion protection Marking
Terminal boxes TNCN Terminal Boxes TNCN The TNCN range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main box is manufactured
More informationGREATER VERSATILITY WITH LESS DOWNTIME
GREATER VERSATILITY WITH LESS DOWNTIME PlexPower Distribution Panelboards EASY TO INSTALL, OPERATE AND MAINTAIN. The PlexPower panelboard is engineered to meet your precise requirements today. Easily upgradeable
More informationGuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4
1. Introduction: This instruction manual contains important information regarding the safety instructions, installation, operation, maintenance and storage of the Guardbox limit switch boxes. The limit
More informationPRE Series 125 Amp Plugs and Sockets Increased Safety
s and Receptacles ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles PRE Series 125 Amp s and Sockets - IK10 Applications s and sockets are used with stationary or portable electrically operated devices
More informationFlameproof Enclosures
Flameproof Enclosures The range comprises many standard sizes of enclosures manufactured in stainless steel 316L and/or in painted carbon steel. The enclosures allow for utilization of standard electrical
More information11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**
Assembly Instructions for: S1 Assembly to S Junction Instructions Boxes for: MS1 to MS Junction Boxes Boxes MS1 to MS Junction Boxes IMPORTANT: This document should be read carefully before commencing
More informationInstallation Instructions for Appleton Mercmaster LED Luminaire
650559-000 INSTRUCTION SHEET Installation Instructions for Appleton Mercmaster LED Luminaire FOR PROPER AND SAFE INSTALLATION OF THIS PRODUCT, PLEASE READ THE FOLLOWING INSTRUCTIONS. Product Safety Signal
More informationATX PRE Series 125 Amp Plugs and Sockets Increased Safety
ATX PRE Series 125 Amp s and Sockets Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL
More informationThe Ex-Cell-I series is made for instrumentation with easy access central locking system and hinged cover.
E X - T E R M I N A L E N C L O S U R E S Stainless Steel Version for Zone and Zone 2 The enclosure range is an ATEX certified enclosure / termination solution for category 2 (Zone) application with an
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning
More informationExplosionproof Protection Simplified
Explosionproof Protection Simplified Appleton Plexpower Lighting and Power Panelboards Product Overview Brochure Easy To Install, Operate and Maintain. The Appleton PlexPower Panelboards by Emerson use
More informationJBDA and JBDF ECDA and ECDF Series Customized Enclosures Flameproof
JBDA and JBDF ECDA and ECDF Series Customized Enclosures ATEX/IEC: Zone 1 and 2 21 and 22 II 2 GD IP66 IK10 Applications Designed for use in Zones 1, 2, 21 and 22 in the oil and gas industry such as: Petroleum
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet painted > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE
More informationFluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety
Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety Zone & & II GD IP66/67 IK0 Applications: Can be installed in hazardous
More informationFlameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C
Enclosures Flameproof - Group IIB or IIB + 2 Carbon steel - DE8BC series The flameproof control cabinets DE8BC are designed for the control, automation, distribution boards, motor starters or any other
More informationJunction Boxes & Enclosures JBES Series: Pre-drilled 316L Stainless Steel Junction Boxes Increased Safety
Je10 Without Terminals ompliance ata: TEX - IE: TEX IE E Ex e II; Ex ia II; Ex ib II T6 to T5 Ex t 21 T80 to T95 Operating Temperatures: -50 to +70 199 TX Product atalog pplications: Terminal junction
More informationEx m Solenoid Operator Type 0519
nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for
More informationSPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot
SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter
More informationOperating Instructions
Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety
More informationControl Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations
Unicode 2 Series: Pre-drilled Control Stations Polamide U43W211 Polyester U23W211 Compliance Data: ATEX IEC and IECEx (Polyester): Stainless Steel U62W229 Aluminum U83W211 ATEX IEC / IECEx CE Ex de IIC
More informationAssembly. Trunk IN + - S U, I U, I. Spur 1
FieldBarrier FD0-FB-Ex.* Features Assembly outputs Ex ia IIC FieldBarrier in Zone /Div. Instruments in Zone 0.../Div. Short circuit current limitation per output For FOUNDATION Fieldbus H and PROFIBUS
More informationGlass Reinforced Polyester Enclosures
42 The GRP range comprises 16 sizes of enclosure manufactured in glass reinforced polyester (GRP). This material is highly resistant to contamination from oils, fats, aliphatic and aromatic carbohydrates,
More informationFE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
: : Applications Can be installed in hazardous areas designated as Zone 1, 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationNXT Series Enclosures
AEx Class I, Zone 1, AEx e IIC, T6 Features/Applications: The NXT series of enclosures available in two types of material finish have been designed to accommodate rail mounted terminals or other electrical
More informationPlug and Socket Devices SolConeX 16 A Series 8570
Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control
More informationFE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
: : Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationVALIADIS S.A. HELLENIC MOTORS
Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe
More informationACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS
Z A H LO C ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS BASIC CATALOG NUMBERS HKHPBMMSS1 HKHPBMMTC1 HKHPBILLMM1 HKHPBMMMR1 HKHPBMMMB1 HKHPBMMMG1 HKHDBLPBMMGR1 HKHPBPMTMR1 HKHPBPMTMB1 HKHPBPMTMG1 HKHPBTMTMR1
More informationVersions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve
Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE
More informationDimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,
Assembly Instructions for junction boxes type: Assembly Instructions for: S1 to S / SFI1 to SFI / SFE1 to SFE S1 to S Junction Boxes MS1 to MS Junction Boxes IMPORTANT: This document should be read carefully
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS RTECK terminal boxes RTKB series IEC Ex EX010 TECHNICAL FILES CONTENTS: 1) Contents 2) General information 3) Safety information 4) Conformity to standards 5) Function 6) Technical
More informationSITRANS P measuring instruments for pressure
Overview Application The pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with
More informationMercmaster LED Series Luminaires Enclosed and Gasketed Fixtures
Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical
More informationEx d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series
Ex d S S.1 series - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67 SSC series Temperature sensor box SWS series SF series A.117 S... series Junction boxes
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More informationPlugs & Sockets PRE Series: 16 A Plugs and Sockets Increased Safety
PRE Series: 16 A Plugs and Sockets Increased Safety ELV: Extra Low Voltage Plug Wall Mounting Socket Mobile Socket Flush Socket 20/25 Vac 20/50 Vdc 40/50 Vac LV: Low Voltage Plug Wall Mounting Sockets
More informationExplosion protected terminal boxes type, GHG 72.
1 Technical data 1.1 Plastic terminal boxes GHG 721... ATX type examination certificate BVS 13 ATX 013 X Marking acc. to 94/9/G and standard ATX x (d e mb) II T5* -55 T amb +55 Gb x (d e mb) II T6* -55
More informationSolutions Ex d IIB+H2, Stainless Steel EJBX*
Features Assembly Examples Enclosures manufactured from AISI 316L stainless steel Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d IIB+H2 and Ex tb More than 20 enclosure size options Free
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More informationINSTALLATION &SAFETY DATA SHEET
INSTALLATION &SAFETY DATA SHEET TYPE SIZE 1 TO SIZE 9 JUNCTION BOX (S1 to S9 Stainless Steel MS1 to MS9 Mild Steel) IMPORTANT : THIS DOCUMENT SHOULD BE READ CAREFULLY BEFORE COMMENCING INSTALLATION ZONES
More informationEJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.
EJB Stainless steel bolts - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67 Mounting bracket Hinges in stainless steel Warning labels Silicone gasket between
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationFloodlight LED Series 6125
www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX 6600
> 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600
More informationPosition Switches Series 8060/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationProduct manual cable glands type IR and IB. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands
Product manual cable glands type IR and IB INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these instructions
More informationLoad disconnect switch Series 8146/5-V11
www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation
More informationSegurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions
Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual and Installation Instructions Segurança PSB Heating System Cold applied connection technology Compulsório Type 27-1680-...0/...
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1
> For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX
More informationKaedra Weatherproof DIN Type Enclosures
Multi 9 System Catalog Section 6 Additional System Devices Kaedra Weatherproof DIN Type Enclosures Applications Expandable enclosures for service, industrial, or equipment applications Protects against
More informationEx UPS standard Series 8265
> Guard battery monitoring according to IEC/EN 60079 et seq. > Adjustable buffer time > Battery function test > Potential-free signal outputs > Maximum efficiency > Increased for reliable triggering of
More informationLighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22
FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up 2 x 58 W 2 x18 W Compliance Data: ATEX IEC: Zone 2 22 ATEX IEC CE Ex nr II or na II T6 or T5 or T4
More informationThe safety you rely on.
Cable Glands Global Solutions Catalogue The safety you rely on. Cable Glands & Accessories Global Solutions Introducing Crouse-Hinds by Eaton The leader in electrical products for hazardous, industrial
More informationalso in ATEX Data Sheet Enclosures Klippon POK Glass Fibre reinforced Polyester Enclosures
Data Sheet Enclosures Klippon POK Glass Fibre reinforced Polyester Enclosures also in ATEX Weidmüller s established range of Klippon POK GRP (Glass Fibre reinforced Polyester) enclosures has been updated
More informationPosition Switches Series 8074/2
www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,
More informationCompact Sheet-Steel Light Fittings Series 6114/1
> As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive
More informationPosition Switches Series 8070/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationSOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4
SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4 U 2 1 3 3/2 Series 327 FEATURES The valves are certified according to IEC 61508 Functional Safety data and have SIL-3 capability
More informationTRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom
TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom Annex to IECEx Certificate of Conformity Equipment Range: The design variants covered are either: a) Complete
More informationMagnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)
Level measurement Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF) TC Fluid Control WIKA data sheet LM LM 3001 30.01 for further approvals see page 3 Applications
More informationDirect-acting 3/2 way plunger valve
Direct-acting 3/2 way plunger valve Direct-acting, compact valve with diameter of up to DN 2.5 Vibration-proof, bolted coil system Banjo threaded connection for direct mounting on pneumatic valves Type
More informationEmergency Luminaire with LED Series EXLUX 6009/1 Version IIC
> For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central
More informationHTSB system System overview
HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.
More information5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A
.1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility
More informationLighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety
4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4
More informationJunction box for EKL light
M EKL light Junction box Junction box for EKL light Features Chemical-resistant Temperature-resistant Flame-retardant Absolutely corrosion-proof Seawater-proof Description Polyester enclosures have proven
More informationFL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22
Standard and Emergency Back-Up. Applications Light duty luminaire ideal for commercial and light industrial locations including hazardous areas designated as Zone 2 or 22 environments. Typical applications
More informationPanelboards & Motor Starters
Appleton s ATX series of Increased Safety distribution panels are available in IP66-rated fiberglass reinforced polyester (FRP) or 316L stainless steel and come in multiple sizes depending on the number
More informationCapri ADE 6F - for Armoured Cable
Capri ADE 6F - for Armoured Cable Technical Specification Suitable for the following cable types Steel wire armoured cable (SWA) Steel wire braided cable (SWB) Steel tape armoured cable (STA) Braided marine
More informationGRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators
Ex d GRD-4200 Electronic earthing system - Zone 1, 2, 21, 22 - High quality electronic components - High resistance to corrosion and extreme weather - Safe and reliable over time SIL certified Level 2
More informationMicro Motion 7827 Digital Viscosity Meter
Product Data Sheet PS-001217, Rev. C April 2013 Micro Motion 7827 Digital Viscosity Meter Micro Motion viscosity meters are built to tackle the most demanding process and control applications. Rugged and
More information