Plugs & Sockets PRE Series: 16 A Plugs and Sockets Increased Safety
|
|
- Laurel Dixon
- 5 years ago
- Views:
Transcription
1 PRE Series: 16 A Plugs and Sockets Increased Safety ELV: Extra Low Voltage Plug Wall Mounting Socket Mobile Socket Flush Socket 20/25 Vac 20/50 Vdc 40/50 Vac LV: Low Voltage Plug Wall Mounting Sockets Mobile Socket Flush Socket 100/130 Vac 200/250 Vac 380/415 Vac 480/500 Vac 50/500 Vac (300 to 500 Hz) Compliance Data: ATEX - IECEx: Zone 1 & 2 21 & 22 ATEX IECEx CE Ex de IIC T6 or T5 Ex td A21 T68 C IP66 IK09/10 Amperage: 16 A Operating Temperature: -40 C to +55 C 141 ATX Product Catalog
2 PRE Series: 16 A Plugs and Sockets Increased Safety ATEX / IECEx IP66 - IK09/10 Applications: Plugs and sockets are used with portable or stationery electrical equipment such as lighting systems, conveyors, heaters, motor generators, air conditioning equipment, compressors and pumps For use in corrosive atmospheres and installations in Zone 1 and 2 and 21 and 22 of the oil and gas industry; such as refineries, chemical and petrochemical plants, pipelines, loading docks and onshore and offshore drilling platforms Features: Plug and socket assembly is equipped with a patented silver-plated linear switch which allows a total disconnection of power when plug is removed: - The high voltage contact separation is in a flameproof chamber - The automatic electrical disconnection of each phase is contained in a second flameproof chamber Short circuit protection is 20 ka, while normal reference is 10 ka Different voltages are color coded for easy identification The sockets are keyed to accept only ATX plugs (other plugs can not be inserted) ATX plugs can be used in non-hazardous sockets Wall Mounting Sockets: Three M20 threaded entries (one on the top and two on the bottom) Supplied with one M20 cable gland (Ø 65 to Ø 145 mm) and two M20 blanking plugs Terminal capacity 2 x 4 mm 2 Can be through-wired Fitted with three linked earth terminals Plugs: One PG16 integrated cable gland (Ø 65 to Ø 145 mm) Terminal capacity 25 mm 2 Mobile Sockets: One PG16 integrated cable gland (Ø 65 to Ø 145 mm) Terminal capacity 2 x 4 mm 2 Flush Sockets: Terminal capacity 2 x 4 mm 2 Standard Material of Fixtures: High impact resistance polycarbonate High impact resistance fiberglass reinforced polyester Polyamide Wall Socket Plug Mobile Socket Flush Socket Wall Socket Plug Mobile Socket Flush Socket 2P - 2P+E - 3P - 3P+N+E Polycarbonate Polyamide Polyamide Polyamide Polyester Polyamide Polyamide Polyamide Catalog Number Logic: PRE X 16 X XX Series: PRE = PRE Series Zone 1, 2, 21 and 22 ATEX / IEC Pin Configuration: 2 = 2P 3 = 2P+E 4 = 5 = 3P+N+E 6 = 3P Amps: 16 = 16 A Equipment: P = Plug R = Receptacle (Wall Mounting) M = Mobile Socket F = Flush Socket Voltage: P = Vac 50/60 Hz W 1 = Vdc W = Vac 50/60 Hz Y = Vac 50/60 Hz B = Vac 50/60 Hz R = Vac 50/60 Hz N = Vac 50/60 Hz G = Vac 300 to 500 Hz ATX Product Catalog 142
3 PRE Series: 16 A Plugs and Sockets Increased Safety ATEX / IECEx IP66 - IK09/10 Ordering Information: Extra Low Voltage: ELV 16 A 20/25 Vac 50/60 Hz Wall Socket PRE216RP Plug PRE216PP Mobile Socket PRE216MP Flush Socket 2P PRE216FP Wall Socket 10h PRE316RP Plug 10h PRE316PP Mobile Socket PRE316MP Flush Socket 2P+E PRE316FP Wall Socket PRE616RP Plug PRE616PP Mobile Socket PRE616MP Flush Socket 3P PRE616FP A 20/50 Vdc Wall Socket PRE216RW Plug PRE216PW Mobile Socket auxiliary PRE216MW pin 10h main pin Flush Socket 2P PRE216FW A 40/50 Vac 50/60 Hz Wall Socket PRE216RW Plug PRE216PW Mobile Socket PRE216MW Flush Socket 2P PRE216FW Wall Socket auxiliary pin 12h PRE616RW Plug PRE616PW Mobile Socket main pin PRE616MW Flush Socket 3P PRE616FW Low Voltage: LV 16 A 100/130 Vac 50/60 Hz Wall Socket PRE316RY Plug 4h PRE316PY Mobile Socket L/ PRE316MY Flush Socket 2P+E PRE316FY ATX Product Catalog
4 PRE Series: 16 A Plugs and Sockets Increased Safety ATEX / IECEx IP66 - IK09/10 Ordering Information Continued: Low Voltage: LV 16 A 200/250 Vac 50/60 Hz Wall Socket L/ PRE316RB Plug 6h PRE316PB Mobile Socket PRE316MB Flush Socket 2P+E PRE316FB Wall Socket L PRE416RB L 2 Plug 9h PRE416PB Mobile Socket PRE416MB L 3 key way Flush Socket PRE416FB Wall Socket L1 L PRE516RB Plug 9h PRE516PB Mobile Socket N L PRE516MB Flush Socket 3P+N+E (1) PRE516FB A 380/415 Vac 50/60 Hz Wall Socket L PRE416RR Plug L1 6h PRE416PR Mobile Socket L PRE416MR Flush Socket PRE416FR Wall Socket L1 L PRE516RR Plug 6h PRE516PR Mobile Socket N L PRE516MR Flush Socket 3P+N+E (2) PRE516FR A 480/500 Vac 50/60 Hz Wall Socket PRE416RN Plug 7h PRE416PN Mobile Socket PRE416MN Flush Socket PRE416FN A 50/500 Vac 300/500 Hz Wall Socket L PRE516RG Plug L 2 2h PRE516PG Mobile Socket L1 N PRE516MG Flush Socket 3P+N+E PRE516FG (1) 120/208 V - 144/250 Vac 50/60 Hz (2) 200/346 V - 240/415 Vac 50/60 Hz ATX Product Catalog 144
5 PRE Series: 16 A Plugs and Sockets Increased Safety ATEX / IECEx IP66 - IK09/10 Accessories: Catalog Number Old Catalog Number Pack M5 earth stud via M20 blanking plug PREESTM Earth continuity adaptor via M20 blanking plug PREECAM Technical Data: Breaking Capacity AC 3 ICC Compliances: Hazardous Area Gas Dust Certification Type PCX PCX/EN PCX PCX/EN Equipment Standards: Wall and Mobile Sockets and Plug Flush Socket Ex Standards EN / IEC ; ; ; ; Product Standards EN / IEC ; EMC Standards Other Standards EN / IEC (IP); (IK) Wall and Mobile Sockets and Plug Zones Conforming to ATEX 94/9/CE CE 0081 II 2 G CE 0081 II2 D Symbol of Protection ATEX Symbol of Protection IEC T Rating Ex de IIC T6 for Ta +40 C T5 for Ta +55 C Ex td A21 Surface Temperature NA T68 C Ambient Temperature -40 C Ta +55 C Flush Socket CE Declaration of Conformity C C214 ATEX Certificate LCIE 02 ATEX 6068 LCIE 02 ATEX 0001U LCIE 02 ATEX 6068 LCIE 02 ATEX 0001U IECEx Certificate IECEx LCI IECEx LCI IECEx LCI IECEx LCI Other Certifications GOST GOST GOST GOST Ingress Protection (solid and liquid) 4 kw 220 V 43 kw 240 V 75 kw 380 V 82 kw 415 V 20 ka Impact Resistance (shock) Wall Sockets Plugs Mobile Sockets Flush Sockets Termination 2 x 4 mm2 25 mm2 2 x 4 mm2 2 x 4 mm2 3 x M20 with Cable Entries 1 x cable gland 1 x PG16 integrated 1 x PG16 integrated (dia 65 to 145 mm) cable gland cable gland NA and 2 blanking plugs (dia 65 to 145 mm) (dia 65 to 145 mm) 145 ATX Product Catalog IP66 IK10 (Polyester) and IK09 (Polyamide) NA
6 PRE Series: 16 A Plugs and Sockets Increased Safety ATEX / IECEx IP66 - IK09/10 Dimensions (mm): 16A 2P 2P+E 3P Versions Wall Mounting Sockets Plugs Mobile Sockets Can be mounted on panel - 3 mm thickness maximum Flush Sockets 16A 3P+N+E Versions Wall Mounting Sockets Plugs A B C 3 P + E P + N + E Mobile Sockets Can be mounted on panel - 3 mm thickness maximum Flush Sockets ATX Product Catalog 146
7 PRE Series: 32 A Plugs and Sockets Increased Safety LV: Low Voltage Plug Wall Mounting Socket Mobile Socket Flush Socket 100/130 Vac 200/250 Vac 380/415 Vac 480/500 Vac Compliance Data: ATEX - IECEx Zone 1 & 2 21 & 22 ATEX IECEx CE Ex de IIC T6 or T5 Ex td A21 T68 C IP66 IK10 Amperage: 32 A Operating Temperature: -40 C to +55 C 147 ATX Product Catalog
8 PRE Series: 32 A Plugs and Sockets Increased Safety ATEX / IECEx IP66 - IK10 Applications: Plugs and sockets are used with portable or stationery electrical equipment such as lighting systems, conveyors, heaters, motor generators, air conditioning equipment, compressors and pumps For use in corrosive atmospheres and installations in Zone 1 and 2 and 21 and 22 of the oil and gas industry, such as refineries, chemical and petrochemical plants, pipelines, loading docks, and onshore and offshore drilling platforms Features: Plug and socket assembly is equipped with a patented silver-plated linear switch which allows a total disconnection of power when plug is removed: - The high voltage contact separation is in a flameproof chamber - The automatic electrical disconnection of each phase is contained in a second flameproof chamber Short circuit protection is 20 ka, while normal reference is 10 ka Different voltages are color coded for easy identification The sockets are keyed to accept only ATX plugs (other plugs can not be inserted) ATX plugs can be used in non-hazardous sockets Wall Mounting Sockets: Three M25 threaded entries (one on the top and two on the bottom) Supplied with one M25 cable gland (Ø 8 to Ø 185 mm) and two M25 blanking plugs Terminal capacity 2 x 6 mm 2 Fitted with three linked earth terminals Plugs: One PG21 integrated cable gland (Ø 8 to Ø 185 mm) for 3P+N+E versions Terminal capacity 6 mm 2 Mobile Sockets: One PG21 integrated cable gland (Ø 8 to Ø 185 mm) for 2P+E and versions One PG29 integrated cable gland (Ø 18 to Ø 25 mm) for 3P+N+E versions Terminal capacity 2 x 6 mm 2 Flush Sockets: Terminal capacity 2 x 6 mm 2 Standard Material of Fixtures: High impact resistance fiberglass reinforced polyester Polyamide Wall Socket Plug Mobile Socket Flush Socket Polyester Polyamide Polyamide Polyamide Catalog Number Logic: PRE X 32 X XX Series : PRE = PRE Series Zone 1, 2, 21 and 22 ATEX / IEC Pin Configuration: 3 = 2P+E 4 = 5 = 3P+N+E Amps: 32 = 32 A Equipment: P = Plug R = Receptacle (Wall Mounting) M = Mobile Socket F = Flush Socket Voltage: Y = Vac 50/60 Hz B = Vac 50/60 Hz R = Vac 50/60 Hz N = Vac 50/60 Hz ATX Product Catalog 148
9 PRE Series: 32 A Plugs and Sockets Increased Safety ATEX / IECEx IP66 - IK10 Ordering Information: Low Voltage: LV 32 A 100/130 Vac 50/60 Hz Equipment Pin Configuration Weight (kg) Volume (dm 3 ) Catalog Number Pack Wall Socket 19 7 PRE332RY 1 Plug 4h 05 4 PRE332PY 1 Mobile Socket L/ PRE332MY 1 Flush Socket 2P+E PRE332FY 1 32 A 200/250 Vac 50/60 Hz Wall Socket L/ PRE332RB Plug 6h 05 4 PRE332PB Mobile Socket PRE332MB Flush Socket 2P+E PRE332FB Wall Socket L1 L PRE432RB Plug 9h 05 4 PRE432PB Mobile Socket PRE432MB L 3 key way Flush Socket PRE432FB Wall Socket L1 L PRE532RB Plug 9h 05 4 PRE532PB Mobile Socket N L PRE532MB Flush Socket 3P+N+E (1) PRE532FB A 380/415 Vac 50/60 Hz Wall Socket L PRE432RR Plug L1 6h 04 4 PRE432PR Mobile Socket L PRE432MR Flush Socket PRE432FR Wall Socket L1 L PRE532RR Plug 6h 05 4 PRE532PR Mobile Socket N L PRE532MR Flush Socket 3P+N+E (2) PRE532FR A 480/500 Vac 50/60 Hz Wall Socket 2 7 PRE432RN Plug 7h 04 4 PRE432PN Mobile Socket 1 4 PRE432MN Flush Socket PRE432FN (1) 120/208 V - 144/250 Vac 50/60 Hz (2) 200/346 V - 240/415 Vac 50/60 Hz 149 ATX Product Catalog
10 PRE Series: 32 A Plugs and Sockets Increased Safety ATEX / IECEx IP66 - IK10 Accessories: Catalog Number Old Catalog Number Pack M6 earth stud via M25 blanking plug PREESTM Technical Data: Breaking Capacity AC 1 AC A 500 V 11 kw 220 V 12 kw 240 V 19 kw 380 V 207 kw 415 V Earth continuity adaptor via M25 blanking plug PREECAM Wall Sockets Plugs Mobile Sockets Flush Sockets Termination 2 x 6 mm 2 6 mm 2 2 x 6 mm 2 2 x 6 mm 2 Cable Entries 3 x M25 with 1 x cable gland (dia 8 to 185 mm) and 2 blanking plugs ICC 20 ka (dia 18 to 25 mm) (dia 18 to 25 mm) Compliances: Hazardous Area Gas Dust Certification Type PCX PCX/EN PCX PCX/EN Equipment Wall and Mobile Sockets Wall and Mobile Sockets Flush Socket and Plug and Plug Flush Socket Zones Conforming to ATEX 94/9/CE CE 0081 II 2 G CE 0081 II2 D Symbol of Protection ATEX Symbol of Protection IEC Ex de IIC Ex td A21 T Rating T6 for Ta +40 C T5 for Ta +55 C NA Surface Temperature NA T68 C Ambient Temperature -40 C Ta +55 C CE Declaration of Conformity C C214 ATEX Certificate LCIE 02 ATEX 6068 LCIE 02 ATEX 0001U LCIE 02 ATEX 6068 LCIE 02 ATEX 0001U IECEx Certificate IECEx LCI IECEx LCI IECEx LCI IECEx LCI Other Certifications GOST GOST GOST GOST Ingress Protection (solid and liquid) IP66 Impact Resistance (shock) IK10 Standards: Ex Standards EN / IEC ; ; ; ; Product Standards EN / IEC ; EMC Standards Other Standards EN / IEC (IP); (IK) 2P+E and 2P+E and 1 x PG21 integrated 1 x PG21 integrated cable gland cable gland (dia 8 to 185 mm) (dia 8 to 185 mm) 3P+N+E 3P+N+E 1 x PG29 integrated 1 x PG29 integrated cable gland cable gland NA ATX Product Catalog 150
11 PRE Series: 32 A Plugs and Sockets Increased Safety ATEX / IECEx IP66 IK10 Dimensions (mm): 32A 2P+E 3P+N+E Versions Wall Mounting Sockets Plugs A B C 2 P + T P + T P + N + T A B C D 2 P + E P + E P + N + E Mobile Sockets Can be mounted on panel - 3 mm thickness maximum Flush Sockets 151 ATX Product Catalog
12 PRE Series: 63 A Plugs and Sockets Increased Safety 63 A Wall Mounting Socket 63A Wall Mounting Socket Through-Wired 63A Plug Compliances: ATEX - IEC: Zone 1 & 2 21 & 22 ATEX IEC CE Ex de IIC T6 or T5 Ex td A21 T90 C IP66 IK10 Electrical Data: Voltage Up to 690 V Amperage 63 A Operating Temperature: -30 C to +55 C ATX Product Catalog 152
13 PRE Series: 63 A Plugs and Sockets Increased Safety ATEX / IEC IP66 IK10 PLUGS & sockets Applications: Plugs and sockets are used with stationary or portable electrically operated devices such as welding devices, lighting systems, conveyers, heaters, motor generator sets, air conditioners, compressors and pumps For use in corrosive atmospheres and installations in Zones 1, and 2 and 21 and 22 of oil and gas industry; such as refineries, chemical, petrochemical plants, pipelines, offshore and onshore drilling platforms Features: Positive polarization: only ATX plugs of same style, number of poles and ampere rating may be used with these sockets Interlocked 3-pole or 4-pole Ex de disconnecting on-load switch, with auxiliary early break contact (capacity 25 mm 2 max) Plug is mechanically locked in socket when switch is ON Switch operating handle can be padlocked in OFF position (max 4 padlocks ) Plug cannot be inserted or removed unless switch is in OFF position Socket Outlet: Standard versions: Supplied with one M50 cable gland for unarmored cable Ø 28 to Ø 42 mm, and one M25 blanking plug Terminal capacity 1 x 35 mm 2 Through-wired versions: Supplied with two M50 cable glands for unarmored cable Ø 28 to Ø 42 mm, and one M25 blanking plug Terminal capacity 2 x 35 mm 2 Plug: One integrated cable entry for unarmored flexible cable Ø 175 to 29 mm for 3P + E versions Ø 175 to 32 mm for 3P + N + E versions Terminals capacity 16 mm 2 Standard Material of Fixtures: High impact resistance fiberglass reinforced polyester socket Polyamide flap cover and plug Catalog Number Logic: PRE X 63 X XX X X X Series: PRE = PRE Series Zone 1, 2, 21 and 22 ATEX / IEC Certified Pin Configuration: 4 = 5 = 3P+N+E Amps: 63 = 63 A Equipment: P = Plug R = Receptacle Voltage: B = Vac 50/60 Hz R = Vac 50/60 Hz N = Vac 50/60 Hz R1 = Vac 60 Hz N1 = Vac 50/60 Hz Cable Type: A = Armored U = Unarmored Cable Entry Size: 3 = M32* 4 = M40* 5 = M50* 6 = M63* * with one M25 plugged entry Options: S = 316L Stainless Steel T = Through-wired Ordering Information: Standard Versions: 63 A 200/250 Vac 50/60 Hz Wall Socket 8 26 PRE463RBU Plug 1 7 PRE463PB A 380/415 Vac 50/60 Hz Wall Socket 8 26 PRE463RRU Plug 1 7 PRE463PR Wall Socket 8 26 PRE563RRU Plug 1 7 PRE563PR P+N+E (1) (1) 200/346 V 240/415 Vac 50/60 Hz 153 ATX Product Catalog
14 PRE Series: 63 A Plugs and Sockets Increased Safety ATEX / IEC IP66 IK10 Ordering Information Continued: 63 A 440/460 Vac 60 Hz Wall Socket 8 26 PRE463RR1U Plug 1 7 PRE463PR Wall Socket 8 26 PRE563RR1U Plug 1 7 PRE563PR P+N+E (2) (2) 250/440 V 265/460 Vac 60 Hz PLUGS & sockets 63 A 480/500 Vac 50/60 Hz Wall Socket 8 26 PRE463RNU Plug 1 7 PRE463PN Wall Socket 8 26 PRE563RNU Plug 1 7 PRE563PN P+N+E (3) (3) 277/480 V 288/500 Vac 50/60 Hz 63 A 600/690 Vac 50/60 Hz Wall Socket 8 26 PRE463RN1U Plug 1 7 PRE463PN Wall Socket 8 26 PRE563RN1U Plug 1 7 PRE563PN P+N+E (4) (4) 347/600 V 400/690 Vac 50/60 Hz Through-wired Versions: 63 A 380/415 Vac 50/60 Hz Wall Socket PRE463RRU5T 1 Wall Socket PRE563RRU5T 1 3P+N+E (1) (1) 200/346 V 240/415 Vac 50/60 Hz ATX Product Catalog 154
15 PRE Series: 63 A Plugs and Sockets Increased Safety Zone 1 & 2 21 & 22 ATEX / IEC IP66 IK10 Compliances: Hazardous Area Gas Dust Certification Type PC63X Zones Conforming to ATEX 94/9/CE CE 0081 II 2 G CE 0081 II 2 D Symbol of Protection ATEX Symbol of Protection IEC T Rating Ex de IIC T6 for Ta +40 C T5 for +40 C Ta +55 C Ex td A21 Surface Temperature T90ºC Service Temperature -30 C to +55 C CE Declaration of Conformity ATEX Certificate LCIE 99 ATEX 6004 IEC Certificate LCIE Ex Other Certifications Ingress Protection (solid and liquid) Impact Resistance (shock) GOST IP66 IK10 Standards: Ex Standards EN / IEC ; ; ; ; Product Standards EN / IEC ; EMC Standards Other Standards EN / IEC (IP); EN (IK) Dimensions (mm): Standard Version: Through-Wired Version: 2 cable entries M8 4 Ø7 Fix146 Fix187 M25 Blanking Plug fitted Ø65 Fix PLUGS & sockets 155 ATX Product Catalog
16 PRE Series: 125 A Plugs and Sockets Increased Safety PLUGS & sockets 125 A Plug 125 A Wall Mounting Socket Compliances: ATEX - IEC: Zone 1 & 2 21 & 22 ATEX IEC CE Ex de IIC T6 or T5 Ex td A21 T90 C IP66 IK10 Electrical Data: Voltage Up to 690 V Amperage 125 A Operating Temperature: -30 C to +55 C ATX Product Catalog 156
17 PRE Series: 125 A Plugs and Sockets Increased Safety Zone 1 & 2 21 & 22 ATEX / IEC IP66 IK10 PLUGS & sockets Applications: Plugs and sockets are used with stationary or portable electrically operated devices such as welding devices, lighting systems, conveyers, heaters, motor generator sets, air conditioners, compressors and pumps For use in corrosive atmospheres and installations in Zones 1 and 2 and 21 and 22 of the oil and gas industry; such as refineries, chemical, petrochemical plants, pipelines, offshore and onshore drilling platforms Features: Positive polarization: only ATX plugs of same style, number of poles and ampere rating may be used with these sockets Interlocked 3-pole or 4-pole Ex de disconnecting on-load switch, with auxiliary early break contact (capacity 25 mm 2 max) Plug is mechanically locked in socket when switch is ON Switch operating handle can be padlocked in OFF position (max 4 padlocks) Plug cannot be inserted or removed unless switch is in OFF position Socket Outlet: One M63 cable gland for unarmored cable Ø 36 to Ø 44 mm, and one M25 blanking plug Terminal capacity 120 mm 2 Plug: One integrated cable entry for unarmored flexible cable Ø 30 to Ø 48 mm Terminals capacity 50 mm 2 Standard Material of Fixtures: 316L stainless steel socket Polyamide flap cover and plug Catalog Number Logic: PRE X 12 X XX X X X Series : PRE = PRE Series Zone 1, 2, 21 and 22 ATEX / IEC Certified Amps: 12 = 125 A Equipment: P = Plug R = Receptacle Voltage: R = Vac 50/60 Hz N = Vac 50/60 Hz R1 = Vac 60 Hz N1 = Vac 50/60 Hz Cable Entry Size: 3 = M32* 4 = M40* 5 = M50* 6 = M63* * with one M25 plugged entry Pin Configuration: 4 = 5 = 3P+N+E Cable Type: A = Armored U = Unarmored Options: T = Through-wired Ordering Information: 125 A 380/415 Vac 50/60Hz Wall Socket PRE412RRU Plug PRE412PR Wall Socket PRE512RRU h Plug PRE512PR P+N+E (1) (1) 200/346 V 240/415 Vac 50/60 Hz 157 ATX Product Catalog
18 PRE Series: 125 A Plugs and Sockets Increased Safety Zone 1 & 2 21 & 22 ATEX / IEC IP66 IK10 Ordering Information Continued: 125 A 440/460 Vac 60 Hz Wall Socket PRE412RR1U Plug PRE412PR Wall Socket PRE512RR1U Plug PRE512PR P+N+E (2) (2) 250/440 V 265/460 Vac 60 Hz PLUGS & sockets 125 A 480/500 Vac 50/60 Hz Wall Socket PRE412RNU Plug PRE412PN Wall Socket PRE512RNU Plug PRE512PN P+N+E (3) (3) 277/480 V 288/500 Vac 50/60 Hz 125 A 600/690 Vac 50/60 Hz Wall Socket PRE412RN1U Plug PRE412PN Wall Socket PRE512RN1U Plug PRE512PN P+N+E (4) (4) 347/600 V 400/690 Vac 50/60 Hz ATX Product Catalog 158
19 PRE Series: 125 A Plugs and Sockets Increased Safety Zone 1 & 2 21 & 22 ATEX / IEC IP66 IK10 PLUGS & sockets Compliances: Hazardous Area Gas Dust Certification Type PC125X Zones Conforming to ATEX 94/9/CE CE 0081 II 2 G CE 0081 II 2 D Symbol of Protection ATEX Symbol of Protection IEC T Rating Ex de IIC Ex td A21 T6 for Ta +40 C T5 for Ta +55 C Surface Temperature T90ºC Service Temperature -30 C to +55 C CE Declaration of Conformity ATEX Certificate LCIE 99 ATEX 6031 IEC Certificate LCIE Ex Other Certifications Ingress Protection (solid and liquid) Impact Resistance (shock) GOST IP66 IK10 Standards: Ex Standards EN / IEC ; ; ; ; Product Standards EN / IEC ; EMC Standards Other Standards EN / IEC (IP); EN (IK) Dimensions (mm): Standard Version: 159 ATX Product Catalog
ATX PRE Series 63 Amp Plugs and Sockets Increased Safety
ATX PRE Series 63 Amp s and Sockets Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator
More informationATX PRE Series 125 Amp Plugs and Sockets Increased Safety
ATX PRE Series 125 Amp s and Sockets Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator
More informationPRE Series 63 Amp Plugs and Sockets Increased Safety
Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator sets Air conditionings Compressors
More informationPage Title Page Subtitle Page Subtitle Notes
PLUGS Page Title & SOCKETS Page Subtitle Page Subtitle Notes Page Classifications With a broad range of power capacities and pin configurations, Appleton s ATX plugs and sockets are standard equipment
More informationPRE Series 125 Amp Plugs and Sockets Increased Safety
s and Receptacles ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles PRE Series 125 Amp s and Sockets - IK10 Applications s and sockets are used with stationary or portable electrically operated devices
More informationControl Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations
Unicode 2 Series: Pre-drilled Control Stations Polamide U43W211 Polyester U23W211 Compliance Data: ATEX IEC and IECEx (Polyester): Stainless Steel U62W229 Aluminum U83W211 ATEX IEC / IECEx CE Ex de IIC
More informationLighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety
4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4
More informationFluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety
Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety Zone & & II GD IP66/67 IK0 Applications: Can be installed in hazardous
More informationPanelboards & Motor Starters
Appleton s ATX series of Increased Safety distribution panels are available in IP66-rated fiberglass reinforced polyester (FRP) or 316L stainless steel and come in multiple sizes depending on the number
More informationATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22
Applications Can be installed in hazardous areas designated as Zone 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection against
More informationLighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22
FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up 2 x 58 W 2 x18 W Compliance Data: ATEX IEC: Zone 2 22 ATEX IEC CE Ex nr II or na II T6 or T5 or T4
More informationLighting: Incandescent & HID Lighting PB, PC & PL Series: Floodlights Flameproof
Ex de IIB Type PB Ex de IIC Type PC Ex de IIB Type PL Low Temperature Rating Compliances: ATEX - IEC: Zone 1 & 2 21 & 22 ATEX IECEx CE Ex de IIB (PB and PL) T4 to T1 Ex td A21 T130 C to T378 C IP66 (Type
More informationATX DPD Series Distribution Panelboards Flameproof
ATX DPD Series Distribution Panelboards Applications Protection and control of electrical equipment in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation
More informationMechanical features. Spring-loaded elastic terminals: resist vibrations
DXN 20 A 32 A 63 A Explosive atmospheres as standard Compact & robust design Safe & easy operation DXN decontactors are designed for explosive atmospheres, with de protection mode. They comply with the
More information20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!
& WATERTIGHT DECONTACTOR DXNCOMPACT 20 A / 32 A / 63 A II2 G D Ex de IIC WATER- AND DUST-TIGHT INTEGRATED LOAD-BREAK SWITCH ROBUST AND COMPACT DESIGN HIGH PERFORMANCE POLY CASING DXN decontactors are designed
More informationFE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
: : Applications Can be installed in hazardous areas designated as Zone 1, 2, 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationJunction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety
JBES Series Medium Voltage 11 kv ECES Series Compliance Data: ATEX - IEC: ATEX IEC CE Ex e II Ex ia IIC; Ex ib IIC T6 to T4 Ex td A21 T80 C to T130 C Ex de IIC; Ex demb IIC Operating Temperatures: -50
More informationATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationUnicode 2 Series Pre-Drilled Control Stations Increased Safety Polyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum
Unicode 2 Series Pre-Drilled Control Stations Polyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum, Type 4X ; Type 4X Applications Local control stations and motor control stations
More informationFE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety
: : Applications Can be installed in hazardous areas designated as Zone 1 and 2 21 and 22. For use in locations where a high degree of corrosion resistance is required. For indoor/outdoor use where protection
More informationATX PC Series Floodlights Flameproof. Metal Halide, High Pressure Sodium, Mercury Vapor, Halogen
Applications Designed for large area lighting in industrial outdoor and indoor hazardous areas. Ideal for use in Zones 1 and 2 and 21 and 22 in the oil and gas industry. In locations such as: refineries,
More informationFL Series Light Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2 and 22
Standard and Emergency Back-Up. Applications Light duty luminaire ideal for commercial and light industrial locations including hazardous areas designated as Zone 2 or 22 environments. Typical applications
More informationEX-REPAIR AND MAINTENANCE RECEPTACLES
EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand
More informationPXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS 10 A TECHNICAL FEATURES
PXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS II2 G D Ex e ia or ib IIC FROM 12 TO 37 CONTACTS LOCKING IN CONNECTED OR DISCONNECTED POSITION CORROSION-FREE METAL CASING TECHNICAL FEATURES PXN12C DXN25C
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More informationJBDA and JBDF ECDA and ECDF Series Customized Enclosures Flameproof
JBDA and JBDF ECDA and ECDF Series Customized Enclosures ATEX/IEC: Zone 1 and 2 21 and 22 II 2 GD IP66 IK10 Applications Designed for use in Zones 1, 2, 21 and 22 in the oil and gas industry such as: Petroleum
More informationLinear fittings EVDL LED fitting - zones 21, & 22
ABB DTS LINEAR FITTINGS - EVDL LED FITTING - ZONES 21 & 22 77 Linear fittings EVDL LED fitting - zones 21, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in
More informationLinear fittings EVNL LED fitting - zones 2, & 22
65 Linear fittings EVNL LED fitting - zones 2, & 22 LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress
More informationJBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped
Enclosures and Junction Boxes Enclosures and Junction Boxes: Hazardous Location Outlet Boxes Applications Instrumentation junction boxes are used to run process or remote information to control room. For
More informationUnused flameproof threads for cable glands have to be closed with certified plugs.
E X - P L U G A N D R E C E P T A C L E 1 A Metallic Design for Zone 1 The explosion-protected light metal plug and receptacle devices can be used in the areas of Zone 1 and Zone 2 at no risk of explosion.
More informationSWITCH SHOULD BE ON THE UPPER SIDE!
COMPACT AND WATERTIGHT DECONTACTOR 20 A / 32 A / 63 A AUTOMATIC WATER- AND DUST-TIGHT SEALING AC-22 AND AC-23 BREAKING CAPACITY IMPACT-RESISTANT GRP CASING With sizes from 20 to 63 A, DSN decontactors
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning
More informationPlug and Socket Devices SolConeX 16 A Series 8570
Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control
More information110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W
/27 V - 2/2 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE 963 39 Fluo 2 x 8 W 963 37 Fluo W 963 36 Fluo 2 x 8 W 8, 36 and 8 W fluorescent luminaires Ø 26 mm bi-pin tubes, standard G3
More informationEasy and safe installation
ATX LUMINAIRES 7 Easy and safe installation 1 2 3 Safety Plus : 1- Mounting can be completed with one hand 2- One handed opening using standard tool 3- Reflector swivels easy access 4- Terminal shield
More information20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!
COMPACT AND WATERTIGHT DECONTACTOR 20 A / 32 A / 63 A AUTOMATIC ip66/ip67 water- and dust-tight sealing AC-22 and ac-23 breaking capacity Impact-resistant GRP casing With sizes from 20 to 63 A, DSN decontactors
More informationI Ex-Safety switches I
3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX
More informationSWITCH SHOULD BE ON THE UPPER SIDE!
COMPACT AND WATERTIGHT DECONTACTOR 20 A / 32 A / 63 A AUTOMATIC WATER- AND DUST-TIGHT SEALING AC-22 AND AC-23 BREAKING CAPACITY IMPACT-RESISTANT GRP CASING With sizes from 20 to 63 A, DSN decontactors
More informationI 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I
I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de
More informationI Ex-safety switches I
3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99
More informationProducts for. Section
2 Products for Section Chemical Industries Grain silos Oil and Gas industry Plastics Fertilisers and insecticides Wood Cosmetics and perfumes lcohol and spirits Pharmaceutical Industries, etc. 90 2005-2006
More informationMain current switches >180 A are realized in metal enclosures. Internationally approved.
E X - M A I N C U R R E N T S W I T C H E S 10 A - 80 A (up to 630 A) CEAG main current switches in a number of versions can be protected against inadvertent switching on by our integrated locking facility
More informationLinear fittings EVTL Weatherproof LED fitting - Industrial applications
89 Linear fittings LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress protection All components mounted
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
More information2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps
.4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency
More informationPlugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581
Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked
More informationDECONTACTOR. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates
DECONTACTOR Switch with socket-outlet. The plugs and sockets as well as socket-outlet boxes and junction boxes in this range are meant for use in hazardous areas in compliance with the ATEX 2014/35/EU
More informationThe cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals
E X - J U N C T I O N B O X Plastic version for Zone 1,, 1 and The robust junction boxes made of plastic and light alloy are featured by their simple mounting and installation capability and their design.
More informationI Ex-safety switches I
EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL
More informationDECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A
DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A SAFE AND SIMPLE CONNECTION, EVEN AT 250 A SAFETY SHUTTER GRP OR METAL CASING The DS family of decontactors offer ratings from 30 to 250 A (ratings
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated
More informationEXEL-L. Detail of the internal side. Transparent polycarbonate
EXEL-L - Complete with high efficiency LED tubes - Quick access to the internal electrical equipment - Double locking system operated by hexagonal-head tool - Zone 1, 2, 21, 22 Reinforced polyester resin
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact
More informationLED Linear Luminaire Series EXLUX 6402
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581
Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked in position 0 and 1 > Clear
More informationGRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators
Ex d GRD-4200 Electronic earthing system - Zone 1, 2, 21, 22 - High quality electronic components - High resistance to corrosion and extreme weather - Safe and reliable over time SIL certified Level 2
More informationAppleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.
ppleton s TX product line includes a wide selection of both Increased Safety and lameproof cable glands for use with unarmored and armored cable. ppleton's TX cable glands are available in a wide range
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE
More informationDSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A
DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A Automatic IP66/IP67/IP69k AC-22 and ac-23 breaking capacity Chemical resistant GRP UL 94 casing Impact resistance IK08, vibration resistance -40
More information10 Load and Motor Switchgear
10 Load and Motor gear Safety es 01941E00 Safety switches ensure the obligatory isolation of electrical power under condition of equipment cleaning, maintenance and repair. Other methods of isolation,
More informationDNROBUST DECONTACTOR 20 A / 30 A / 50 A / 90 A / 150 A SILVER-NICKEL BUTT CONTACTS
DNROBUST DECONTACTOR 20 A / 30 A / 50 A / 90 A / 150 A AUTOMATIC IP54/ WATER- AND DUST-TIGHT IMPACT-RESISTANT METAL CASING SUITABLE FOR HEAVY INDUSTRY The DN family of decontactors cover ratings from 30
More informationSales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
Product description 2 Product key features COOPER Crouse-Hinds EVZ series HID pendant luminaire is Ex de designed with rugged fixture and impact duration tempered glass globe. It has 2 versions with full
More informationM-0. M-0... series control, monitoring and signalling devices. Ex e
M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere
More informationInternational approvals.
E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for
More informationDSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A
DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A Automatic IP66/IP67/IP69k AC-22 and ac-23 breaking capacity Chemical resistant GRP UL 94 casing Impact resistance IK08, vibration resistance -40
More informationMOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS. hyconelec.co.za MARECHAL TECHNOLOGY
MOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS hyconelec.co.za MARECHAL TECHNOLOGY SAFE AND RELIABLE ELECTRICAL CONNECTIONS FOR YOUR MOTORS. MARECHAL ELECTRIC offers a range of
More informationLinear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22
ABB DTS LINEAR FITTINGS - EVS FLUORESCENT FITTING - S, 2, 2 & 22 59 EVS fluorescent fitting with easy disconnect - zones, 2, 2 & 22 Features Easy disconnect without wiring to remove the gear tray All components
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX 6600
> 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600
More informationIIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof
IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof Zone 1 & 2-21 & 22 ATEX IEC EC II2G/D IK 08 99 EEx d IIC T6-T5-T4-T3 T = 75 C to 135 C IP 66 0947 36 wellglass luminaire
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationEXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components
EXENC-L - Zone 2, Zone 21-22 - Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components Resin body reinforced polyester Fixing Brackets Transparent hood
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More information11 Control Panels, Distribution Panels and Components
Control Panels, Distribution Panels and Components Motor Switches Explosion protection to CENELEC IEC For use in Zone and Zone Isolator Motor switching capacity Rated working voltage up to Rated working
More information5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A
.1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility
More information2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)
.15 Ex-Linear luminaires for T5 HE fluorescent lamps (Zone and ) The energy-saving lighting solution Certified for use in hazardous areas in Zone and, the linear luminaires series nllk 10 for T5 fluorescent
More informationInternationally approved.
E X - M A N U A L M O T O R S T A R T E R S Up to 2 A Motors have to be protected against over loads, phase failures and overheating: CEAG s power circuit breaker and manual motor starter features phase-failure
More informationEmergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy
www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5
More informationINDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates
INDUSTRIAL PLUGS A range from 16 A to 600 A 1000 V. Automatic watertightness from IP44 to 66/67. From -40 to +240 C. GRP or metal casing. Reliable & compact. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com
More informationSafety Switches Series 8537
Safety Switches www.stahl.de > 3- and 6-pole switches 12 / 16, 25, 40, 63 / 80, 125 / 160, 250, 315, 400, 500 A > Motor switching capacity AC-3 and AC-23 acc. to IEC 60947-3, EN 60947, DIN VDE 0660 part
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationEx eb IIC Gb Ex ia IIC Ga Ex Tb IIIC Db DRILLING AND ASSEMBLY OF JBEP JUNCTION BOXES AND ENCLOSURES GUIDE
Ex eb IIC Gb Ex ia IIC Ga Ex Tb IIIC Db DRILLING AND ASSEMBLY OF JBEP JUNCTION BOXES AND ENCLOSURES GUIDE To easily accommodate your unique application requirements and maintain compliance with certification
More information7 Lighting Technology
7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:
More information4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)
.5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust
More informationDECONTACTOR SWITCH WITH SOCKET-OUTLET
DECONTACTOR SWITCH WITH SOCKET-OUTLET This extensive and comprehensive product range covers all industrial applications. With sizes up to 400 A, it offers a wide range of mounting and installation options.
More informationATX D Series Actuators, Pilot Lights, Contact Blocks, Switches and Accessories Flameproof
ATX D Series Actuators, Pilot Lights, Contact Blocks, Switches and Accessories Applications Suitable for use with certified flameproof Ex d enclosures for control equipment. Features DIN rail mounted (TS35)
More informationNew products Ex Equipment 2015
New products Ex Equipment 2015 ROSE Systemtechnik GmbH ROSE Systemtechnik GmbH was founded in Porta Westfalica, Germany, in 199 and is today one of the world s leading and innovative providers of industrial
More informationLinear fittings EVN Fluorescent fitting - zones 2 & 22
LIEAR FITTIGS - EV FLUORESCET FITTIG - ZOES 2 & 22 71 EV Fluorescent fitting - zones 2 & 22 Features Double central locking for ingress protection All components mounted on hinged and removable gear tray
More informationSPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot
SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter
More informationLinear fittings EVTL Weatherproof LED fitting - Industrial applications
89 Linear fittings LED Features Operating life up to 100 000 h High lumen output - 5 000 lumens with 100% yield - LED module with diffuser Double central locking for ingress protection All components mounted
More informationFONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0)
Features: FONTECK INDUSTRIES BFBD BIFURCATED FAN (ATEX Certified, Gas Group IIB+H2) ATEX Certified Comply with standards: EN 14986, EN 13463 1 Driven directly by ATEX certified motor 15 sizes with case
More informationFONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0)
Features: FONTECK INDUSTRIES AFBD AXIAL FAN (ATEX Certified, Gas Group IIB+H2) ATEX certified Comply with standard: EN 14986, EN13463 1 Driven directly by ATEX certified motor 15 sizes with case opening
More informationYFC. Limit switch. Ex d. 24 operating head types
Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735
More informationEmergency Luminaire with LED Series EXLUX 6009/1 Version IIC
> For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More informationEmergency Luminaire with LED Series EXLUX 6409/1
> Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually
More informationTERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS
OSUR CL HA ES EN KILLARK Z LO C SJIC SERIES TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS Screw cover style, with or without continuous hinge 3/16 (5mm) wide flat flange for maximum gasket surface
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationJunction boxes for control, monitoring and control panel Ex tb
Junction boxes for control, monitoring and control panel - Zone 21, 22 - Category 2D - Aluminium, reinforced polyester or stainless steel enclosures - Standard or custom products Inspection window Padlockable
More information