1 F Piping Systems Signet Measurement and Instrumentation Price List effective January 1, 2018 NEW! DryLoc ph/orp Smart Sensor Electronics See page 37 for new lower pricing on Portaflow Ultrasonic Flow Meters!

2 Conveyance Pipe, Fittings, Joining Technology // PVC/CPVC // PPro-Seal PP // PROEF PP // SYEF PVDF // Contain-It // Double-See // Fuseal Special Waste // COOL-FIT ABS // ecofit PE Measurement Chlorine // Dissolved Oxygen // Turbidity // Flow/Batch // ph // ORP // Conductivity // Pressure // Temperature // Level Control Ball Valves // Butterfly Valves // Diaphragm Valves // Pressure Regulating Valves // Electric Actuation // Pneumatic Actuation

3 Table of contents Multi-Parameter Instruments 1 Chlorine 9 Turbidity 16 Dissolved Oxygen 17 Flow 18 ph/orp 38 Conductivity/Resistivity 45 Temperature, Pressure, Level 49 Other Products 58 Installation and Weld-on Fittings 62

4

5 Multi-Parameter Instruments Multi-Parameter Instruments Dual Channel Transmitter Instruments: One instrument for multiple sensor types Two different sensor types can be combined in one instrument Configurable display Derived measurements Optional modules can be added for additional capabilities USB Port for field upgrades using standard USB flash drive MFR # Inputs Output Mount Power Two Channel Multi-Parameter Two 4 to 20 ma Panel Mount DC Two Channel Multi-Parameter Two 4 to 20 ma Panel Mount AC / DC Part No. USD , , Relay Module MFR # Relays Part No. USD With 4 Mechanical Relays With 2 Mechanical and 2 Solid State Relays With 2 Mechanical Relays and 4 Binary Inputs SmartPro Transmitter Instruments: Large auto-sensing backlit display with at-a-glance visibility "Dial-type" digital bar graph Optional field upgradable relays Custom 13-character label capabilities for the channel type Intuitive and "user-friendly" interface consistent with legacy Signet ProPoint and ProcessPro devices MFR # Description Part No. USD P 9900 Panel Mount Field Mount

6 9900 Modules Relay Module Dry-contact relays are electromechanical switches with a moving contact armature. They are suitable for many general purpose applications, AC or DC, including loads up to 250 V. Install RC Filter kits ( ) on relays used to switch motor or inductive loads. This module adds two programmable dry-contact relays to the standard Open Collector output on the base unit. MFR # Description Part No. USD SP Relay Module - 2 DCR (Dry-contact relays) Modules Conductivity/Resistivity Module The Direct Conductivity/Resistivity Module interfaces Signet and Conductivity electrodes directly to the The moduel also provides filtering and conditioning. (Conductivity/Resisitivity and Salinity measurements may also be performed via the 2850 Sensor Electronics connected through the 9900 Digital (S3L) intputs.) MFR # Description Part No. USD SP Direct Conductivity/Resistivity Module Modules H COMM Module The H COMM Module enables communication between the 9900 and a HART - enabled device. The HART (Highway Addressable Remote Transducer) Protocol superimposes digital signals on top of the 4 to 20 ma analogue signal. MFR # Description Part No. USD SP H COMM Module i-o 8058 Signal Converter Features: Connects with level, temperature, pressure and multi-parameter Signet instruments Up to two 4 to 20mA sensor inputs Connects additional measurement parameters to Signet Multi-Parameter instruments Wire or DIN rail mountable MFR # Description Part No. USD Single input wire-mount with short cable Two input DIN rail mount to 20 ma Output Module Instruments: The 4 to 20 ma Output Midule adds a second 4 to 20 ma Output to the 9900 Transmitter (eneration III and newer). Each of the outputs can be used to output the primary and/or secondary measurement. Outputs have individual settings available. MFR # Description Part No. USD to 20 ma Output Module

7 9900-1BC BC Batch Contoller System Instruments: Customize 10 batch names for easy distinction between batches Store up to 10 batch sizes for batching or blending a variety of liquid volumes Remote control wiring with start, stop & resume terminals for remote batch control 3 programmable relays Two-stage control to prevent overfilling or to minimize water hammer Enter 10 different K-Factors - one per batch for when different liquids are batched MFR # Description Part No. USD BC Batch Controller System , BC Batch Module MFR # Description Part No. USD Batch Module

8 9900 Instrument Enclosures Instrument mounted through solid, hinged, door With 24VDC power supply input VAC 50/60 Hz, mounted to DIN rail With terminal blocks, pre-wired wiring harness 4 Conduit holes with cable connectors MFR # Description Part No. USD P-S P Panel Mount Transmitter, (1) input, , (1) 4-20mA and (1) OC outputs, DC power, P-393-S P-393 Panel Mount Transmitter, (1) , input, (1) 4-20mA and (1) OC outputs, DC power, (2) Dry Contact Relays P P Panel Mount Transmitter, , S (1) input, (1) 4-20mA and (1) OC outputs, DC power, (2) Dry Contact Relays, Cond/Resist Module P-394-S P-394 Panel Mount Transmitter, (1) , input, (1) 4-20mA and (1) OC outputs, DC power, Cond/Resist Module P-398-S P-398 (1) input, (2) 4-20mA and (1) OC outputs, DC power , P S P (1) input, (2) 4-20mA and (1) OC outputs, DC power, (2) Dry Contact Relays , Instrument Enclosures Instrument mounted through solid, hinged, door Input VAC 50/60 Hz (optional 24VDC) With terminal blocks, pre-wired wiring harness 4 Conduit holes with cable connectors MFR # Description Part No. USD S Transmitter, (2) Input, (2) 4-20mA, AC/DC , Power S Transmitter, (2) Input, (2) 4-20mA, AC/DC , Power, (4) Mechanical Dry Contact Relays S Transmitter, (2) Input, (2) 4-20mA, AC/DC , Power, (2) Mechanical, (2) Solid State Dry Contact Relays S Transmitter, (2) Input, (2) 4-20mA, AC/DC Power, (2) Mechanical, (4) Binary Input ,

9 9900 Transmitter Accessories and Replacement Parts MFR # Description Part No. USD weight (kg) Relay Module - 2 DCR (Dry-contact relays) H COMM Module Direct Conductivity/Resistivity Module Batch Module Conductivity Module Plug, 4 Pos, Right Angle DC Power Plug, 2 Pos, Right Angle Relay Module Plug, 3 Pos, Right Angle Loop Power Plug, 4 Pos, Right Angle Terminal Block Plug Freq/S3L Plug, 4 Pos, Right Angle Universal Mount Kit RC Filter Kit Integral Adapter /4 in. Integral Mount Kit Single input wire-mount with short cable Two input DIN rail mount NPT (1 pc.) Standard Connector Kit, Right Angle * Optional Connector Kit, In-Line Call Wall Mount Accessory Kit Call Angle Adjustment Adapter Kit (for Field Mounting) VDC Power Supply, 10W, 0.42 A VDC Power Supply, 24W, 1.0 A VDC Power Supply, 40W, 1.7 A VDC Power Supply, 60W, 2.5 A VDC Power Supply, 96W, 4.0 A to 20 ma Output Module Rear Enclosure Hinged Cover Rear Enclosure Flat Cover

10 Multi-Parameter Controller Base units, required - choose one Instruments: Display: Backlit LCD, 2x16 alphanumeric characters Sensor Input: Up to 6 inputs, Analog or Digital (S3L) or Pulse (2 max for pulse) Analog Output: Up to Four, 4-20mA isolated, passive/active option or 0-5VDC or 0-10VDC Relay/Solid-State Output: Up to 4 Internal and up 2 or 4 more external contact relays (via 8059) Compatible Sensors: All Signet Digital/Pulse Output Flow Sensors, 2250, 2350, 2450, 2750, 2850, 8058-x MFR # * Description Part No. USD Required Base Unit with LCD Required Two inputs, no outputs Required Two inputs, two passive 4 to 20mA outputs Required Two inputs, two active 4 to 20mA outputs Required Two inputs, two 0 to 5/10 VDC outputs Required Four inputs, no outputs Required Four inputs, two passive 4 to 20mA outputs Required Four inputs, two active 4 to 20mA outputs Required Four inputs, two 0 to 5/10 VDC outputs Required Six inputs, no outputs Required Six inputs, two passive 4 to 20mA outputs Required Six inputs, two active 4 to 20mA outputs Required Six inputs, two 0 to 5/10 VDC outputs , Required 85 to 264 VAC power Required 12 to 24 VDC power Optional Two dry-contact relays Optional Two solid-state relays Optional Two passive 4 to 20mA outputs Optional Two active 4 to 20mA outputs Multi-Parameter Controller Accessories and Replacement Parts Instruments: Display: Backlit LCD, 2x16 alphanumeric characters Sensor Input: Up to 6 inputs, Analog or Digital (S3L) or Pulse (2 max for pulse) Compatible Sensors: All Signet Digital/Pulse Output Flow Sensors, 2250, 2350, 2450, 2750, 2850, 8058-x Analog Output: Up to Four, 4-20mA isolated, passive/active option or 0-5VDC or 0-10VDC Relay/Solid-State Output: Up to 4 Internal and up 2 or 4 more external contact relays (via 8059) MFR # Description Part No. USD terminal plug (for I/O Module) terminal plug (for Power Module) terminal plug (for Dry-contact Relays) Rear Panel w/ Captive Screws Call Front Face Panel asket terminal plug, 2 ea. (for SSR & Outputs 3 & 4)

11 Digital Display Instruments Type 8150 Battery Powered Flow Totalizer Instruments: Display: 4-digit upper line and 8-digit lower line Sensor Input: 1 input Power Input: Two 3.6V Lithium Thionyl Chloride, AA size, 4 years nominal battery life Relay/O.C. Output: None Current Output: None Compatible Sensors: 515, 525 Flow Sensors MFR # Integral Sensor Sensor Type Part No. USD N/A P N/A P P0 -X , P P1 -X , T T0 -X , Instrument Accessories and Replacement Parts Power Supply, RC Filter, Batteries, Converter MFR # Description For Type Part No. USD RC Filter Kit Lithium Repl. Battery Single input wire-mount with short cable Two input DIN rail mount Liquid Tight Connector Kits MFR # Description Part No. USD For Type For rear cover (3 pc.) All instruments NPT (1 pc.) All instruments P13.5 (1 pc.) All instruments Instrument mounting and accessories, 5000 Series MFR # Description Part No. USD For Type Splashproof rear cover kit series x 5 in. adapter plate series Window kit series Model 200 retrofit adapter series, mount bracket All instruments Heavy duty wall mnt bracket All instruments Wall mount , 8000 series 7

12 Instrument mounting 8000 series MFR # Description Part No. USD Universal Mount Kit Universal Mount Junction Box Splashproof rear cover RC Filter Kit Wall mount /4 in. Integral Mount Kit /4 in. Junction Box Wall mount Retaining nut replacement kit, Valox K MFR # For Type series series series , , 8350, 8450, , 8350, 8450, , 8000 series

13 Chlorine H 4630 Chlorine Analyzer System Chlorine: Reagent free measuring Complete panel system allows for quick and easy installation Built-in flow regulator maintains constant flow and pressure to the sensors regardless of inlet pressure MFR # Description Part No. USD Chlorine pnl, trnsmtr, free chlorine sensor (0 to 2 ppm) w/electronics (no ph sensor) , Chlorine pnl, trnsmtr, free chlorine sensor (0 to 5 ppm) w/electronics (no ph sensor) , Chlorine pnl, trnsmtr, free chlorine sensor (0 to 20 ppm) w/electronics (no ph sensor) , Chlorine pnl, trnsmtr, free chlorine sensor (0 to 2 ppm) w/electronics w/ph sensor) , Chlorine pnl, trnsmtr, free chlorine sensor (0 to 5 ppm) w/electronics w/ph sensor) , Chlorine pnl, trnsmtr, free chlorine sensor (0 to 20 ppm) w/electronics w/ph sensor) ,

14 H 4632 Chlorine Dioxide Analyzer System Chlorine: Reagent free measuring Panel includes a VAC power supply, two 4 to 20 ma outputs and two mechanical relays relays Built-in flow regulator maintains constant flow and pressure to the sensors regardless of inlet pressure Complete panel system allows for quick and easy installation MFR # Description Part No. USD Chlorine Dioxide panel, 0 to 2 ppm/mg/l, no ph sensor , Chlorine Dioxide panel, 0 to 2 ppm/mg/l, with ph sensor ,

15 H 2630 Amperometric Chlorine Electrode MFR # Description Part No. USD Free Chlorine electrode, 0 to 2 ppm (mg/l) * Free Chlorine electrode, 0 to 5 ppm (mg/l) * Free Chlorine electrode, 0 to 20 ppm (mg/l) * H 2632 Chlorine Dioxide Electrode Chlorine: Embedded memory chip accessible via the Signet 8630 transmitter Quick assembly with Signet's patented DryLoc connector Integrated temperature element for automatic temperature compensation Separate drive electronics (Signet 2650), for easy electrode replacement without running new cable MFR # Part No. USD Description * Chlorine Dioxide electrode, 0 to 2 ppm (mg/l 11

16 H 2650 DryLoc Amperometric Electronics MFR # Description Part No. USD Amperometric in-line sensor electronics, digital (S3L), 4.6 m (15ft) cable

17 H 8630 Chlorine Transmitter MFR # Description Part No. USD P Panel mount chlorine and ph transmitter ph Sensor Electronics MFR # Description Part No. USD ph electronics, digital (S3L), 4.6 (15ft) cable

18 Chlorine Accessories and Replacement Parts 4630 Chlorine Analyzer System 4630 Chlorine Analyzer System Accessories and Replacement Parts MFR # Description Part No. USD Free Chlorine electrode, 0 to 2 ppm (mg/l) * Free Chlorine electrode, 0 to 5 ppm (mg/l) * Free Chlorine electrode, 0 to 20 ppm (mg/l) * ph sensor, flat glass, PT1000 temp element, 3/4 in. MNPT * Amperonmetric in-liine sensor electronics, digital (S3L), 4.6 m (15ft) cable ph electronics, digital (S3L), 4.6 (15ft) cable P Panle mount chlorine and ph transmitter Rebuild kit, O-rings, boots, screws, 1 filter screen Pressure regulator with 1 spare filter screen Acrylic flow cell complete with all components and connections , Free Chlorine electrolyte, 30 ml Free Chlorine Replacement PTFE membrane (1) * Free Chlorine Sensor maintenance kit - (2) electrolyte and (2) PTFE membranes, (2) silcone bands * ph buffer kit (1 ea4, 7, 10 powder form) * ph 4 buffer solution, 1 pt (473 ml) * ph 7 buffer solution, 1 pt (473 ml) * ph 10 buffer solution, 1 pt (473ml) * Calibration kit, 3 PP cups, 1 pt ea 4, 7 solu * H 4632 Chlorine Dioxide Analyzer System MFR # Description Part No. USD Amperonmetric in-liine sensor electronics, digital (S3L), 4.6 m (15ft) cable ph Electrode, Flat, 3/5 in. NPT Thread * Chlorine Dioxide electrody, 30 ml * Chlorine Dioxide maintenance kit - (2) electrolyte, (2) PTFE membranes, (2) silicone bands and polishing paper * P Panle mount chlorine and ph transmitter Chlorine Dioxide electrode, 0 to 2 pp, (mg/l) * ph electronics, digital (S3L), 4.6 (15ft) cable Rebuild kit, O-rings, boots, screws, 1 filter screen Pressure regulator with 1 spare filter screen Acrylic flow cell complete with all components and connections , Free Chlorine Replacement PTFE membrane (1) * Flow Switch kit, Chlorine PP H 2630 Amperometric Chlorine Electrode MFR # Description Part No. USD Free Chlorine electrolyte, 30 ml Free Chlorine Replacement PTFE membrane (1) * Free Chlorine Sensor maintenance kit - (2) electrolyte and (2) PTFE membranes, (2) silicone bands *

19 8630 Chlorine Transmitter MFR # Description Part No. USD Splashproof rear cover Heavy duty wall mnt bracket mount bracket RC Filter Kit For rear cover (3 pc.) NPT (1 pc.) P13.5 (1 pc.)

20 Turbidity H 4150 Turbidimeter Turbidity: Simple and easy one-unit installation with built-in pressure regulator EPA compliant per U.S. EPA or ISO 7027 Programmable 4-20 ma output Easy access for wiring and maintenance Ultrasonic cleaning option insures long and steady on-line measurement Compatibility: 8058 i-o Signal Converter MFR # Description Part No. USD White Light, 0 to 1000 NTU/FNU, no self cleaning , Infrared, NTU/FNU, no self cleaning , White Light, 0 to 100 NTU/FNU, with ultrasonic auto self cleaning , Infrared, NTU/FNU, with ultrasonic auto self cleaning , White Light, 0 to 1000 NTU/FNU, with ultrasonic auto self cleaning , Infrared, NTU/FNU, with ultrasonic auto self cleaning , Turbidimeter Accessories and Replacement Parts H Spare Parts for 4150 MFR # Description Part No. USD Calibration kit, Turbidity, 100, 10 & 0.02 NTU/FNU * Calibration kit, Turbidity, 1000, 10 & 0.02 NTU/FNU * Replacement Desiccant Formazin Stock Kit * Formazin Stock Solution, 4000 NTU/FNU, 500 ml * Replacement Cuvette Set (3 glass cuvettes) Replacement Cuvette with Ultrasonic Transducer O-ring for cuvette IPC standard, 10 NTU nominal value Call Pressure Regulator Stilling-Bubble Chamber Tubing kit, 1 shutoff clamp, 1 backpressure valve Turbidity lamp replacement kit, white

21 Dissolved Oxygen H 2610 Process Optical Dissolved Oxygen Sensor Dissolved Oxygen: No membranes or filling solutions Optical DO measurement no flow requirements Rugged construction Calibration built into the measurement cap 2% of range 0 to 20 mg/l One year measurement cap life Flexible communications, 4 to 20 ma or Modbus (RS485) Measurement Range: 0 to 20 mg/l MFR # Description Part No. USD Optical Dissolved Oxygen Sensor (0 to 20 ppm) with S3L, Modbus, and 4 to 20 ma output * , Dissolved Oxygen Threaded Pipe Adapter Replacement Optical Dissolved Oxygen Sensor Cap (0 to 20 ppm)

22 Flow Paddlewheel Flow Sensors Type 515 Type 515 Rotor-X Standard Mount Paddlewheel Flow: Operating range: 0.3 to 6 m/s, 1 to 20 ft/s Installs into pipe sizes: DN15 to DN900, 0.5 to 36 in Max Pressure rating: PP C, F PVDF C, F Power source: Self powered Rotor: PVDF Compatibility: 5090, 8150, 8550, 8900, 9900, BC *Only Signet installation fittings MFR # Body Pin Pipe Size Sensor Part No. USD Type P51530-H0 PP Hastelloy C X P51530-P0 PP Titanium X P51530-P1 PP Titanium X P51530-P2 PP Titanium X P51530-S0 PP PVDF X P51530-T0 PVDF PVDF X P51530-T1 PVDF PVDF X P51530-V0 PVDF Hastelloy C X P51530-V1 PVDF Hastelloy C X P51530-V2 PVDF Hastelloy C X Type 515 Rotor-X Integral Mount Paddlewheel (use with Accessory) Flow: Highly chemical resistant materials Self powered, no power supply needed Rotor: PVDF MFR # Body Pin Pipe Size DN-DN Sensor Type Part No. USD P0 PP Titanium X P1 PP Titanium X T0 PVDF PVDF X V0 PVDF Hastelloy-C X

23 Type515 Rotor-X Wet-Tap Mount Paddlewheel (use with Type 3519 wet tap valve) Flow: Operating range: 0.3 to 6 m/s, 1 to 20 ft/s Installs into pipe sizes: DN15 to DN900, 0.5 to 36 in Max Pressure rating: PP C, F PVDF C, F Power source: Self powered Compatibility: 8150, 8550, 8900, 9900, BC MFR # Pipe Size DN-DN Part No. USD P51530-P P51530-P P51530-P Rotors and Rotor Kits 515 MFR # For Description Part No. USD Type M Rotor, PVDF Black P Rotor, PVDF Natural M Rotor, PTFE P Rotor and Pin, PVDF Natural Sleeved Rotor, PVDF Black Sleeved Rotor, PVDF Natural Sleeved Rotor, Tefzel M , Pin, Titanium M , Pin, Hastelloy-C M , Pin, Tantalum M , Pin, Stainless Steel 316 (1.4401) P , Pin, Ceramic

24 Type 2536 Type 2536 Rotor-X Standard Mount Paddlewheel Flow: Operating range: 0.1 to 6 m/s, 0.3 to 20 ft/s Open collector output Installs into pipe sizes: DN15 to DN900, 0.5 to 36 in Max Pressure rating: PP C, F PVDF C, F Rotor: PVDF Compatibility: 8900, 9900, BC, 9950 Power source: 3.3 to 24 VDC *Only Signet installation fittings PVC 2536 version DN15 to DN100 (1/2 to 4 in.) for concentrated Sodium Hypochlorite 12.5% dosing application in water treatment MFR # Body Pin Pipe Size Sensor Part No. USD Type P0 PP Titanium X P1 PP Titanium X P2 PP Titanium X T0 PVDF PVDF X V0 PVDF Hastelloy C X V1 PVDF Hastelloy C X U0 PVC Titanium X Type 2536 Rotor-X Integral Mount Paddlewheel (use with Accessory) Flow: Operating range: 0.1 to 6 m/s, 0.3 to 20 ft/s Installs into pipe sizes: DN15 to DN900, 0.5 to 36 in Max Pressure rating: PP C, F PVDF C, F Power source: 3.3 to 24 VDC Compatibility: 8900, 9900, BC, 9950 *Only Signet installation fittings Rotor: PVDF Open collector output MFR # Body Pin Pipe Size DN-DN Sensor Type Part No. USD P0 PP Titanium X P1 PP Titanium X T0 PVDF PVDF X V0 PVDF Hastelloy C X

25 Type 2536 Rotor-X Wet-Tap Mount Paddlewheel (use with type 3519 wet tap valve) Flow: Operating range: 0.1 to 6 m/s, 0.3 to 20 ft/s Installs into pipe sizes: DN15 to DN900, 0.5 to 36 in Max Pressure rating: PP C, F PVDF C, F Power source: 3.3 to 24 VDC Compatibility: 8900, 9900, BC, 9950 *Only Signet installation fittings Rotor: PVDF Open collector output MFR # Body Pin Pipe Size DN-DN Part No. USD P3 PP Titanium P4 PP Titanium P5 PP Titanium Rotors and Rotor Kits 2536 and 2537 MFR # Description Part No. USD SP Rotor, PVDF Black Rotor, PVDF Natural Rotor, PTFE Rotor and Pin, PVDF Natural Sleeved Rotor, PVDF Black Sleeved Rotor, PVDF Natural Sleeved Rotor, PTFE M Pin, Titanium M Pin, Hastelloy-C M Pin, Tantalum M Pin, Stainless Steel 316 (1.4401) P51545 Pin, Ceramic

26 Spare Parts 515/2536 MFR # Description Part No. USD weight (kg) P31542 Sensor Cap, Red P31934 Conduit Cap P51589 Conduit Adapter Kit Integral Adapter P31536 Sensor Plug, PP Cable (2 Conductor, shield) Retaining nut replacement kit, Valox K Replacement nut replacement kit, NPT, PP Replacement nut replacement kit, NPT, PVDF Integral mounting kit, NPT, PP Integral mounting kit, NPT, PVDF Sensor cap, gray Call MFR # For Type P P , 2536 P , , 2536 P , Sensor Plug 515/2536/2537 MFR # For Type Description Part No. USD 515, 2536, P31536 Sensor Plug, PP O-Rings 515/2536/2537 MFR # For Type Description Part No. USD , 2536, O-ring, FKM (2 req'd per sensor) , 2536, O-ring, EPR (EPDM) (2 req'd per sensor) , 2536, O-ring, FFPM (2 req'd per sensor)

27 Type 2537 Rotor-X Flow: Installs into pipe sizes: DN15 to DN200, 0.5 to 8 in Operating range: 0.1 to 6 m/s, 0.3 to 20 ft/s Outputs: Digital S3L, 4 to 20 ma or multi-function Max Pressure rating: PP C, F PVDF C, F Power source: Digital - 5 VDC nominal, Relay & 4-20 ma - 24 VDC nominal Compatibility: 8900, 9900, BC, 9950 Rotor: PVDF MFR # Output Body Pin Pipe Size Part No. USD Pulse/Flow Switch, C-P0 DCR, -P0, Integral PP Titan Mount C-P0 Pulse/Flow Switch, SSR, -P0, Integral PP Titan Mount C-P0 Digital (S3L) output, -P0, Integral Mount PP Titan C-P ma output, - P0, Integral Mount PP Titan C-P1 Pulse/Flow Switch, DCR, -P1, Integral PP Titan Mount C-P1 Pulse/Flow Switch, SSR, -P1, Integral PP Titan Mount C-P1 Digital (S3L) output, -P1, Integral Mount PP Titan C-P ma output, - P1, Integral Mount PP Titan C-T0 Pulse/Flow Switch, DCR, -T0, Integral PVDF PVDF Mount C-T0 Pulse/Flow Switch, SSR, -T0, Integral PVDF PVDF Mount C-T0 Digital (S3L) output, -T0, Integral Mount PVDF PVDF C-T ma output, - T0, Integral Mount PVDF PVDF Type 525 Metalex (use with Metalex Weld-On Mini-Tap, Socket Weld Mini-Tap) Flow: Installs into pipe sizes: 0.5 to 12 in, DN15 to DN300 Operating range: 1.6 to 20 ft/s, 0.5 to 6 m/s Max Pressure rating: Socket weld or weld on fittings 103 bar, 1500 psi (@ safety factor 1.5) Power source: Self powered Compatibility: 8150, 8550, 8900, 9900, BC MFR # Pin Pipe Size DN-DN Part No. USD P525-1 Tungsten Carbide P525-2 Tungsten Carbide P525-1S 316 Stainless Steel P525-2S 316 Stainless Steel

28 Rotor Kit, Pin, Cable, Conduit Adapter for 525 MFR # Description Part No. USD For Type P52509 Rotor kit (with stainless pin) P Rotor kit (with tungsten carbide pin) P Rotor pin, Stainless steel 316 (1.4401) P Rotor pin,tungsten Carbide P52618 asket P52503 Bearing, carbon fiber reinforced PTFE P52527 Retainers, Stainless steel , 2540 P52628 Fitting cap kit (cap and gasket) P51589 Conduit Adapter Kit , Cable (per foot) 2 cond. w/shield, 22 AW Type 3519 Flow Wet-Tap Valve Flow: Installs into pipe sizes: DN15 to DN900, 0.5 to 36 in Material: PVC body, seals FKM or EPDM Max Pressure rating: 7 20 C, (100 F) MFR # Description Pipe Size DN-DN Part No Wet-Tap Valve only /515-P3 Valve with Model , /515-P4 Valve with Model , /515-P5 Valve with Model , /2536-P3 Valve with Model , /2536-P4 Valve with Model , /2536-P5 Valve with Model , USD 24

29 Type 2540 Type 2540 Stainless Steel Standard Flow: *Recommended ( ) Hot Tap installation tool (sold separately) Installs into pipe sizes: DN40 to DN600, 1.5 to 24 in Operating range: 0.1 to 6 m/s, 0.3 to 20 ft/s Max Pressure rating: C, FOptional EPDM: C, F Power source: 5 to 24 VDC, 1.5mA max Compatibility: 8900, 9900, BC, 9950 MFR # Mounting Rotor Pin Part No. USD in. NPT thread Tungsten Carb in. ISO thread Tungsten Carb S 1.5 in. NPT thread Stainless Steel S 1.5 in. ISO thread Stainless Steel Type 2540 Stainless Steel Hot Tap Flow: Installs into pipe sizes: DN40 to DN 900, 1.5 in. to 36 in. Operating range: 0.1 to 6 m/s, 0.3 to 20 ft/s Max Pressure rating: C, FOptional EPDM: C, F Power source: 5 to 24 VDC, 1.5mA max Compatibility: 8900, 9900, BC, 9950 *Recommended ( ) Hot Tap installation tool (sold separately) MFR # Mounting Rotor Pin Part No. USD in. NPT thread Tungsten Carb , in. ISO thread Tungsten Carb , S 1.5 in. NPT thread Stainless Steel , S 1.5 in. ISO thread Stainless Steel ,

30 Rotor Kit, O-ring, Cable for 2540 Hot-Tap Description MFR # Part No. USD Hot-Tao Install. Tool , O-ring, FKM (2 req'd per sensor) O-ring, EPR (EPDM) (2 req'd per sensor) O-ring, FFPM (2 req'd per sensor) Rotor Kit/(old) Rotor Kit, Tungsten Carbide Pin Bearing, Fluoroloy B /PTFE Retainers, Stainless steel P Standard module Hot-Tap module Conduit Adapter Kit P Conduit Cap P Rotor kit, Stainless steel pin and rotor Rotor pin,tungsten Carbide P Rotor pin, 316 SS P Bearing, carbon reinforced PTFE P For Type , 2536, , 2536, , 2536, , , , Spare Parts for 2540 MFR # Description Part No. USD Hot-Tao Install. Tool , O-ring, FKM (2 req'd per sensor) O-ring, EPR (EPDM) (2 req'd per sensor) O-ring, FFPM (2 req'd per sensor) Rotor Kit/(old) Rotor Kit, Tungsten Carbide Pin Rotor kit, Stainless steel pin and rotor P Rotor pin,tungsten Carbide P Rotor pin, 316 SS P52503 Bearing, carbon reinforced PTFE P52527 Retainers, Stainless steel Standard module Hot-Tap module Cable (2 Conductor, shield) P51589 Conduit Adapter Kit P31934 Conduit Cap

31 Replacement Cable 22 AW for Type 2540 MFR # Description Part No. USD Cable, 3cond. plus shield, 22 AW, black/red Turbine Flow Sensors Type 2100 Flow: Installs into pipe sizes: 0.5 in, DN15 Hose size: DN8, 1/4in, DN10, 3/8 in, DN15, 0.5 in Operating range 0.38 to38 lpm, 0.8 to10 gpm Max Pressure rating:16 20 C,232 F Power source: 5 to 24 VDC, 1.5mA max Compatibility: 8900, 9900, BC, 9950 *End connector kits must be ordered separately. See accessories *-H version can be used with flare fitting. Flow range: 3-27 lpm MFR # Description Flow Range Part No. USD * L FKM o-ring lpm ( gpm) * L EPDM o-ring lpm ( gpm) * H FKM o-ring lpm ( gpm) * H EPDM o-ring lpm ( gpm)

32 End fittings for 2100 MFR # Description Material Size Hose barb connector kit PVDF 1/2" Hose barb connector kit PVDF 3/8" Hose barb connector kit PVDF 1/4" Fusion socket connector kit PVDF DN15 1/2" Butt Fusion/IR connector kit PVDF DN15 1/2" Metric socket connector kit PVC 1/2" SCH 80 socket connector kit PVC 1/2" NPT threaded socket connector kit PVC 1/2" Part No. USD weight (kg) Spare Parts for 2100 MFR # Description Part No. USD For Type O-rings FKM (2 required per sensor) O-rings EPDM (2 required per sensor) Electronics Module with cable Call Universal Mount Junction Box series In-line Rotor Flow Sensors Type 2000 Micro-Flow Flow: Installs into pipe sizes: 0.25 NPT or ISO7/1-R1/4 Threads Operating range:0.11 to12.11lpm, 0.03 to 3.2 U.S. gpm Max Pressure rating: 0 C to 80 C 5.5 bar, 32 F to 176 F at 80 psi max Power source: 5 to 24 10mA Compatibility: 8900, 9900, BC, 9950 MFR # Description Flow Range (l min) Part No. USD NPT threads ISO 7/1-R1/4 threads NPT threads ISO 7/1-R1/4 threads

33 Spare Parts for 2000 MFR # Description Part No. USD For Type Replacement rotor kit Cover O-ring Cover screw Cable (2 Conductor, shield) Universal Mount Junction Box series Type 2507 Mini-Flow Flow: Installs into pipe sizes: 1/4 in, 1/4 NPT Operating range: 400 to 12,000 ml/m (0.1 to 3.2 U.S. gpm) Max Pressure rating: 5.5 C, F Power source: 5 to 24 10mA Compatibility: 8900, 9900, BC, 9950 MFR # Description Flow Range (l min) 1mm insert (available through eorg Fischer DZS only) V 2mm insert V 3 mm insert V 4 mm insert V 6 mm inlet, no insert Part No. USD Call Spare Parts for 2507 MFR # Description Part No. USD Rotor Quad Ring DIN Connector mm Insert mm Insert mm Insert Cable (2 Conductor, shield)

34 Insertion Magmeter Type 2551 Type 2551 Magmeter; Blind Version Frequency or Digital (S 3 L) output Flow: Installs into pipe sizes: DN15 to DN900, 0.5 to 36 in Operating range: 0.05 to10 m/s, 0.15 to 33 ft/s Max Pressure rating: PP C, F Power Source:Frequency: 5 to 24 VDC, 15 ma max.digital (S 3 L): 5 to 6.5 VDC, 15 ma max. Compatibility: 8900, 9900, BC, 9950 *Only Signet installation fittings MFR # Body Electrode Pipe Size Sensor Part No. USD Type P0-11 PP 316L SS X , P1-11 PP 316L SS X , P2-11 PP 316L SS X , T0-11 PVDF Titanium X , T1-11 PVDF Titanium X , T2-11 PVDF Titanium X , V0-11 PVDF Hastelloy C X , V1-11 PVDF Hastelloy C X , V2-11 PVDF Hastelloy C X , Type 2551 Magmeter, Blind Version Current output (4 to 20 ma) Flow: Installs into pipe sizes: DN15 to DN900, 0.5 to 36 in Operating range: 0.05 to10 m/s, 0.15 to 33 ft/s Max Pressure rating: PP C, F Power source: 4to 20mA:21.6 to 26.4 VDC, 21.1mA max *Only Signet installation fittings MFR # Body Electrode Pipe Size Sensor Part No. USD Type P0-12 PP 316L SS X , P1-12 PP 316L SS X , P2-12 PP 316L SS X , T0-12 PVDF Titanium X , T1-12 PVDF Titanium X , T2-12 PVDF Titanium X , V0-12 PVDF Hastelloy C X , V1-12 PVDF Hastelloy C X , V2-12 PVDF Hastelloy C X ,

35 Type 2551 Magmeter; Display Versionwith relays Current output (4 to 20 ma) Flow: Installs into pipe sizes: DN15 to DN900, 0.5 to 36 in Operating range: 0.05 to10 m/s, 0.15 to 33 ft/s Max Pressure rating: PP C, F Power source: 4 to 20mA, 21.6 to 26.4 VDC, 22.1mA maxaux Power for relays, 9 to 24 VDC, 0.4A max *Only Signet installation fittings MFR # Body Electrode Pipe Size Sensor Type Part No. USD P0-22 PP 316L SS 1 4 -X , P1-22 PP 316L SS 5 8 -X , P2-22 PP 316L SS X , T0-22 PVDF Titanium 1 4 -X , T1-22 PVDF Titanium 5 8 -X1 * , T2-22 PVDF Titanium X , V0-22 PVDF Hastelloy C 1 4 -X , V1-22 PVDF Hastelloy C 5 8 -X , V2-22 PVDF Hastelloy C X , Type 2551 Magmeter; Display Version no relays Current output (4 to 20 ma) Flow: Installs into pipe sizes: DN15 to DN900, 0.5 to 36 in Operating range: 0.05 to10 m/s, 0.15 to 33 ft/s Max Pressure rating: PP C, F Power source: 4to 20mA:21.6 to 26.4 VDC, 21.1mA max *Only Signet installation fittings MFR # Body Electrode Pipe Size Sensor Part No. USD Type P0-42 PP 316L SS X , P1-42 PP 316L SS X , P2-42 PP 316L SS X , T0-42 PVDF Titanium X , T1-42 PVDF Titanium X , T2-42 PVDF Titanium X , V0-42 PVDF Hastelloy C X , V1-42 PVDF Hastelloy C X , V2-42 PVDF Hastelloy C X ,

36 Type 2551 Magmeter, Display Version no Relays Frequency or Digital (S3L) output Flow: Installs into pipe sizes: DN15 to DN900, 0.5 to 36 in Operating range: 0.05 to10 m/s, 0.15 to 33 ft/s Max Pressure rating: PP C, F Power Source:Frequency: 5 to 24 VDC, 15 ma max.digital (S 3 L): 5 to 6.5 VDC, 15 ma max. Compatibility: 8900, 9900, BC, 9950 *Only Signet installation fittings MFR # Body Electrode Pipe Size Sensor Part No. USD Type P0-41 PP 316L SS X , P1-41 PP 316L SS X , P2-41 PP 316L SS X , T0-41 PVDF Titanium X , T1-41 PVDF Titanium X , T2-41 PVDF Titanium X2 * , V0-41 PVDF Hastelloy C X , V1-41 PVDF Hastelloy C X1 * , V2-41 PVDF Hastelloy C X , Type 2551 Magmeter; Display Version with relays Frequency or Digital (S³L) output Flow: Installs into pipe sizes: DN15 to DN900, 0.5 to 36 in Operating range: 0.05 to10 m/s, 0.15 to 33 ft/s Max Pressure rating: PP C, F Power Source:Frequency: 5 to 24 VDC, 15 ma max.digital (S 3 L): 5 to 6.5 VDC, 15 ma max. Compatibility: 8900, 9900, BC, 9950 *Only Signet installation fittings MFR # Body Electrode Pipe Size Sensor Part No. USD Type P0-21 PP 316L SS X , P1-21 PP 316L SS X , P2-21 PP 316L SS X , T0-21 PVDF Titanium X , T2-21 PVDF Titanium X1 * , T2-21 PVDF Titanium X2 * , V0-21 PVDF Hastelloy C X , V1-21 PVDF Hastelloy C X1 * , V2-21 PVDF Hastelloy C X ,

37 Special: Integral Systems Magmeter Flow with 9900 Transmitter Flow MFR # Description Sensor Body Pipe Size P with P0 Magmeter PP/SS , T with T0 Magmeter PVDF/Titanium , V with V0 Magmeter PVDF/Hastelloy-C , P with P1 Magmeter PP /SS , T with T1 Magmeter PVDF/Titanium , V with V1 Magmeter PVDF/Hastelloy-C , P with P2 Magmeter PP/SS , T with T2 Magmeter PVDF/Titanium , V with V2 Magmeter PVDF/Hastelloy-C , USD 33

38 Spare Parts for 2551 MFR # Description Part No. USD P0 PP/316L SS, DN15 to DN100 (½ to 4 in.) pipe P1 PP/316L SS, DN125 to DN200 (5 to 8 in.) pipe P2 PP/316L SS, DN250 to DN900 (10 to 36 in.) pipe , T0 PVDF/Titanium, DN15 to DN100 (½ to 4 in.) pipe , T1 PVDF/Titanium, DN125 to DN200 (5 to 8 in.) pipe , T2 PVDF/Titanium, DN250 to DN900 (10 to 36 in.) pipe , V0 PVDF/Hastelloy-C, DN15 to DN100 (½ to 4 in.) pipe , V1 PVDF/Hastelloy-C, DN125 to DN200 (5 to 8 in.) pipe V2 PVDF/Hastelloy-C, DN250 to DN900 (10 to 36 in.) pipe , Magmeter electronics, frequency or digital (S3L) output Magmeter electronics, 4 to 20 ma output O-ring, FKM (2 req'd per sensor) O-ring, EPR (EPDM) (2 req'd per sensor) O-ring, FFPM (2 req'd per sensor Electronics only, display w/relays , Electronics only, display w/relays/4-20ma , Electronics only, display w/freq or dig , Electronics only, display w/4-20ma , Clear plastic cap for display O-ring for clear plastic cap, EPR (EPDM) Retaining nut replacement kit, Valox K Replacement nut replacement kit, NPT, PP Replacement nut replacement kit, NPT, PVDF Type 2552 Type 2552 Magmeter Current output (4 to 20 ma) Flow: Installs into pipe sizes: 2 to 102in, DN50 to DN250 Operating range: 0.05 to10 m/s, 0.15 to 33 ft/s Max Pressure rating: PP C, F Power source: 4to 20mA:21.6 to 26.4 VDC, 21.1mA max MFR # Mounting Connection Part No. USD A in. depth 1 1/4 in. NPT , B in. depth 1 1/4 in. NPT , A in. depth 1 1/4 in. ISO , B in. depth 1 1/4 in. ISO , A in. depth 1 1/2 in. NPT , B in. depth 1 1/2 in. NPT , A in. depth 1 1/2 in. ISO , B in. depth 1 1/2 in. ISO * ,

39 Type 2552 Magmeter Frequency or Digital (S 3 L) output Flow: Installs into pipe sizes: 2 to 102in, DN50 to DN250 Operating range: 0.05 to10 m/s, 0.15 to 33 ft/s Max Pressure rating: PP C, F Power source: 5 to 26.4 VDC, 15mA max Compatibility: 8900, 9900, BC, 9950 MFR # Mounting Connection Part No. USD A in. depth 1 1/4 in. NPT , B in. depth 1 1/4 in. NPT , A in. depth 1 1/4 in. ISO , B in. depth 1 1/4 in. ISO , A in depth 1 1/2 in. NPT , B in depth 1 1/2 in. NPT , A in depth 1 1/2 in. ISO , B in depth 1 1/2 in. ISO , Spare Parts for 2552 MFR # Description Part No. USD ½ x 1¼ in. NPT adapter SS x 1¼ in. NPT adapter SS ¼ in. NPT SS ball valve & nipple kit ¼ in. NPT brass ball valve & nipple kit ½ in. NPT conduit adapter for -2 units ¼ in. NPT valve - brass ¼ in. NPT valve - SS conductor, 22 AW, wtr-tight cntr, 4 m (13 ft) conductor, 22 AW, wtr-tight cntr, 6 m (19.5 ft) Special Order 4-conductor, 22 AW, wtr-tight cntr Special Order Call Flow Sensor Accessories and Replacement Parts Spare Parts for 8550-XXX and XXXL NEC class 2 / LPS compliant Install on DIN rail TS-35/7.5 or 15 Cooling by free air convection Protections: Short circuit/overload/over-voltage Universal A/C input/full range LED indicator for power on Built-in DC OK active signal Instruments: The Batch Module adds batch capability to the 9900 Transmitter eneration II or later. It is compatible with all Signet flow sensors. Up to 10 batch sizes can be stored in one 9900 with customized names and K-Factors available for each batch. Description MFR # Part No. USD For Type Integral Adapter ,

40 O-Rings and askets Description MFR # Part No. USD For Type O-rings FKM (2 required per sensor) O-ring, FKM (2 req'd per sensor) , 2536, 2537 Cover O-ring O-rings EPDM (2 required per sensor) O-ring, EPR (EPDM) (2 req'd per sensor) , 2536, 2537 O-ring, FFPM (2 req'd per sensor) , 2536, 2537 Quad Ring asket P Miscellaneous MFR # Description Part No. USD Universal Mount Kit P V Pipe Adapter Insert, PVDF * P P Pipe Adapter Insert, PVC * P31536 Sensor Plug, PP P31542 Sensor Cap, Red P Sensor Cap, Blue P Pipe Adapter Insert, PVDF 1.5 in P31934 Conduit Cap Cover screw Standard module Hot-Tap module P52527 Retainers, Stainless steel P52628 Fitting cap kit (cap and gasket) Cable, 3cond. plus shield, 22 AW, black/red Cable (per foot) 2 cond. w/shield, 22 AW Integral Adapter MFR # For Type series P V 5 in. to 8 in. pipe fittings P P 5 in. to 8 in. pipe fittings P , 2536 P P P in. pipe fittings P , P , 2540 P ,

41 Ultrasonic flow H Portaflow 330/220 "clamp-on" portable flowmeter Model: Includes transducer guide rail and all mounting hardware Carrying case, cables, manual and other ancillary equipment Portaflow 330 comes with build in data logger d-d 330 A+B USD 220 A USD 220 B USD Part No. Part No. Part No , , , H Ultraflow 3000/4000 Ultrasonic flow transmitter Model: Includes transducer guide rail and all mounting hardware Enclosure rating IP65 Ultraflo 4000 comes with a build in data logger For type B please state with your order:- Cable lenght: 5 or 10 meter- Liquid temperature C: - Liquid type: - Pipe size (d):- Pipe wall thickness : d-d Voltage 3000 A Part No. USD 3000 B Part No. USD 4000 A Part No. USD V AC , , , V DC , , , B USD Part No , , H Ultrasonic thickness gauge Part No. USD Type U1000 Compact Clamp-on Flow Sensor Display Version, 4-20 ma and Pulse Output Principle: non-contact ultrasonic transit time Measuring range: m/s Pipe size [d]: mm Pipe materials: Plastics and steel Output: 4-20 ma, 4-wire, Pulse Integrated display and programming buttons Supply power: V AC/DC MFR # Measuring range (m³ h) Part No. USD U m/s ,

42 ph/orp Preamplifiers 2751 ph/orp DryLoc Smart Sensor Electonics ph/orp: High impedance warning on user selectable threshold Manufacturing and operational data recorded and stored Probe health monitoring, glass impedance and broken glass detection Compatible Instruments: Signet 8900 or 9900 Convenient remote calibration MFR # Mounting Connection Part No. USD In-line DryLoc In-line with EasyCal DryLoc ISO, submersible DryLoc NPT, submersible DryLoc

43 9900pH Calibrator The 9900 battery-operated calibrator is built to enhance the user experience with the new line of 2751 Smart ph/orp sensor electronics. This unit can be kept in a lab or taken in to the field. The calibration storage capability of the ph/orp electrodes when used with the 2751 Smart sensor electronics, allows the user the ability to rotate electrodes, meaning unplug an aged/dirty electrode replacing with a pre-calibrated electrode. With larger installations, all collected dirty and uncalibrated electrodes can be taken to a central well organized location where proper cleaning and calibration can be performed. This improves efficiency of this process, resulting more stable readings, higher sensitivity, faster response time, and overall more accurate readings. Description Part No. USD 9900pH Calibrator

44 Type 2760 ph/orp Preamplifier ph/orp: Compatible Instruments: Signet 8750 Connection: Durable DryLoc with fold plated connections Mounting sytles: In-line integral mount and submersion Compatible sensors: , 2735, Wet-Tap, , MFR # Description Mounting Connection Part No. USD Preamplifier NPT, submersible DryLoc Preamplifier ISO, submersible DryLoc Preamplifier NPT, in-line DryLoc Preamplifier ISO, in-line DryLoc

45 Electrodes Type 2724/2726 DryLoc ph/orp Electrodes (Non returnable) ph/orp: Wetted Materials: Ryton, UHMW polyethylene, FKM, glass Connection: Durable DryLoc with fold plated connections Compatible Preamp/Sensor Electronics: 2750 and 2760 Compatible Instruments: Use the 2760 preamplifier with the Signet 8750; Use the 2750 sensor electronics with the Signet 8900 or the 9900 Transmitter Additional Features: HF and LC options available In-line Mounting styles: Standard 3/4 inch or ISo threaded fittings Submersible mounting: Available using the back of the preamplifier or sensor electronics Applications: Water treatment, water quality monitoring, etc. MFR # Electrode Style Part No. USD ph Flat * ph Flat * ph Flat * ph Flat * ORP Flat * ORP Flat * ph Bulb * ph Bulb * ph Bulb * ph Bulb * HF-00 ph Bulb, HF resist * HF-01 ph Bulb, HF resist * HF-10 ph Bulb, HF resist * HF-11 ph Bulb, HF resist * LC-00 ph Bulb, Low Conductivity * LC-01 ph Bulb, Low Conductivity * LC-10 ph Bulb, Low Conductivity * LC-11 ph Bulb, Low Conductivity * HF-10 ph Flat, HF resistant HF-11 ph Flat, ph resistant Type 2734/2736 DryLoc ph/orp Electrodes ph/orp: Patented reference design for exceptional performance Mounts in Signet standard fittings from DN15 to DN100 (½ to 4 in.) ¾ in. NPT or ISO 7/1-R 3/4 threaded sensors for use with reducing tees DN15 to DN100 (½ to 4 in.) Special design allows for installation at any angle, even inverted or horizonal Ryton (PPS) body and PTFE junction for broad range of chemical compatibility Patented DryLoc connector with gold plated contacts Quick temperature response MFR # Electrode Style Part No. USD ph Flat * ph Flat * HF-00 ph Flat, HF resist * HF-01 ph Flat, HF resist * ph Bulb * ph Bulb * HF-00 ph Bulb, HF resist * HF-01 ph Bulb, HF resist * ORP Flat, 10K * ORP Flat, 10K *

46 Type 2756-WT Wet-Tap DryLoc ph Electrodes MFR # Style Compatible Preamplifier Part No. USD * WTP Bulb, Plastic Wet-Tap 2750 DryLoc * * WTP-1 Bulb, Plastic Wet-Tap 2760 DryLoc * Type 2757-WT Wet-Tap DryLoc ORP Electrodes MFR # Style Compatible Preamplifier Part No. USD * WTP Bulb, Plastic Wet-Tap 2750, 2760 DryLoc * Type 2764/2766 DryLoc ph Electrodes ph/orp: Wetted Materials: Ryton, PTFE, FKM, carbon graphite, glass Connection: Durable DryLoc with fold plated connections Compatible Preamp/Sensor Electronics: 2750 and 2760 Compatible Instruments: Use the 2760 preamplifier with the Signet 8750; Use the 2750 sensor electronics with the Signet 8900 or the 9900 Transmitter Additional Features: Differential reference for additional protection in harsh chemicals; also quick temperature response In-line Mounting styles: Use the sensors 1 inch thread to mount to any in-line tee Submersible mounting: Available using the back of the preamplifier or sensor electronics Applications: Water treatment, water quality monitoring, scrubbers, heavy metal removal, harsh chemicals, etc. MFR # Style Compatible Preamplifier Mounting Part No. USD * Flat 2760 DryLoc with threaded connection * * Flat 2750 DryLoc with threaded connection * * Bulb 2760 DryLoc with threaded connection * * Bulb 2750 DryLoc with threaded connection *

47 Type 2765/2767 DryLoc ORP Electrodes ph/orp: Wetted Materials: Ryton, PTFE, FKM, carbon graphite, glass Connection: Durable DryLoc with fold plated connections Compatible Preamp/Sensor Electronics: 2750 and 2760 Compatible Instruments: Use the 2760 preamplifier with the Signet 8750; Use the 2750 sensor electronics with the Signet 8900 or the 9900 Transmitter Additional Features: Differential reference for additional protection in harsh chemicals; also quick temperature response In-line Mounting styles: Use the sensors 1 inch thread to mount to any in-line tee Submersible mounting: Available using the back of the preamplifier or sensor electronics Applications: Water treatment, water quality monitoring, scrubbers, heavy metal removal, harsh chemicals, etc. MFR # Style Compatible Preamplifier Mounting Part No. USD * Flat 2750, 2760 DryLoc with threaded connection * * Flat 2750, 2760 DryLoc with threaded connection * * Bulb 2750, 2760 DryLoc with threaded connection * * Bulb 2750, 2760 DryLoc with threaded connection * Type 2774/2776 DryLoc ph Electrodes ph/orp: Wetted Materials: Ryton, PTFE, FKM, glass Connection: Durable DryLoc with fold plated connections Compatible Preamp/Sensor Electronics: 2750 and 2760 Compatible Instruments: Use the 2760 preamplifier with the Signet 8750; Use the 2750 sensor electronics with the Signet 8900 or the 9900 Transmitter Additional Features: Quick temperature response and can be mounted upside-down In-line Mounting styles: Standard 3/4 inch or ISo threaded fittings Submersible mounting: Available using the back of the preamplifier or sensor electronics Applications: Water treatment, water quality monitoring, some harsh chemicals MFR # Style Compatible Preamplifier Mounting Part No. USD Flat 2760 DryLoc with threaded connection * Flat 2750 Dryloc with threaded connection * Bulb 2760 DryLoc with threaded connection * Bulb 2750 DryLoc with threaded connection * Type 2775/2777 DryLoc ORP Electrodes ph/orp: Wetted Materials: Ryton, PTFE, FKM, glass Connection: Durable DryLoc with fold plated connections Compatible Preamp/Sensor Electronics: 2750 and 2760 Compatible Instruments: Use the 2760 preamplifier with the Signet 8750; Use the 2750 sensor electronics with the Signet 8900 or the 9900 Transmitter Additional Features: Quick temperature response and can be mounted upside-down In-line Mounting styles: Use the sensors 3/4 inch thread to mount to any in-line tee Submersible mounting: Available using the back of the preamplifier or sensor electronics Applications: Water treatment, water quality monitoring, some harsh chemicals MFR # Style Compatible Preamplifier Mounting Part No. USD * Flat 2750, 2760 DryLoc with threaded connection * * Bulb 2750, 2760 DryLoc with threaded connection *

48 Type 3719 ph/orp Wet-Tap Assembly ph/orp: Wetted Materials: CPVC, FKM Connection: 1.5 or 2 inch NPT or ISO Process Threads Additional Features: Use only with either the 2716 & 2717 or 2756 & 2757 Wet-Tap series electrodes Applications: Water treatment, water quality monitoring, etc. MFR # Style Mounting Part No. USD Wet-Tap assembly 1.5 inch NPT , Wet-Tap assembly 1.5 inch ISO , Wet-Tap assembly 2 inch NPT , Wet-Tap assembly 2 inch ISO ,

49 Conductivity/Resistivity Electrodes Type 2818 Conductivity/Resistivity Electrode MFR # Cell Constant (cm ¹) Electrode Mounting Part No. USD SST 3/4 inch Type 2819 Conductivity/Resistivity Electrode Conductivity/Resistivity: Wetted Materials: 316 SST or Titanium Process Connection Choices: 3/4 inch threads for In-line or Submersion, 1.5 inch Sanitary Triclamp flange and 2 inch Sanitary Tri-clamp flange Cell constants and corresponding measuring ranges: 0.01 cm-1 / 0.55 to 100 μs (18.3 mω to 10 KΩ)0.1 cm-1 / 1 to 1000 μs (1 mω to 1 KΩ)1.0 cm-1 / 10 to 10,000 μs (5 to 5,000 ppm)10.0 cm-1 / 100 to 200,000 μs (50 to 100,000 ppm)20.0 cm-1 / 200 to 400,000 μs (100 to 200,000 ppm) Compatible Instruments: Signet Instrument Types: 8850, or the 9900 with the 2850 Sensor Electronics Thread styles are reversible threads or fixed threads MFR # Cell Constant (cm ¹) Electrode Process Connection Part No. USD SST Threaded C SST Threaded S SST 1.5 inch flange S1C SST 1.5 inch flange S SST 2 inch flange , S2C SST 2 inch flange , T Titanium 1.5 inch flange , T1C 0.01 Titanium 1.5 inch flange , T Titanium 2 inch flange , T2C 0.01 Titanium 2 inch flange ,

50 Type 2820 Conductivity/Resistivity Electrode Conductivity/Resistivity: Wetted Materials: 316 SST or Titanium Process Connection Choices: 3/4 inch threads for In-line or Submersion, 1.5 inch Sanitary Triclamp flange and 2 inch Sanitary Tri-clamp flange Cell constants and corresponding measuring ranges: 0.01 cm-1 / 0.55 to 100 μs (18.3 mω to 10 KΩ)0.1 cm-1 / 1 to 1000 μs (1 mω to 1 KΩ)1.0 cm-1 / 10 to 10,000 μs (5 to 5,000 ppm)10.0 cm-1 / 100 to 200,000 μs (50 to 100,000 ppm)20.0 cm-1 / 200 to 400,000 μs (100 to 200,000 ppm) Compatible Instruments: Signet Instrument Types: 8850, or the 9900 with the 2850 Sensor Electronics Thread styles are reversible threads or fixed threads MFR # Cell Constant (cm ¹) Electrode Process Connection Part No. USD SST Threaded C SST Threaded S SST 1.5 inch flange S1C SST 1.5 inch flange S SST 2 inch flange , S2C SST 2 inch flange , T Titanium 1.5 inch flange , T1C 0.10 Titanium 1.5 inch flange , T Titanium 2 inch flange , T2C 0.10 Titanium 2 inch flange , Type 2821 Conductivity/Resistivity Electrode Conductivity/Resistivity: Wetted Materials: 316 SST or Titanium Process Connection Choices: 3/4 inch threads for In-line or Submersion, 1.5 inch Sanitary Triclamp flange and 2 inch Sanitary Tri-clamp flange Cell constants and corresponding measuring ranges: 0.01 cm-1 / 0.55 to 100 μs (18.3 mω to 10 KΩ)0.1 cm-1 / 1 to 1000 μs (1 mω to 1 KΩ)1.0 cm-1 / 10 to 10,000 μs (5 to 5,000 ppm)10.0 cm-1 / 100 to 200,000 μs (50 to 100,000 ppm)20.0 cm-1 / 200 to 400,000 μs (100 to 200,000 ppm) Compatible Instruments: Signet Instrument Types: 8850, or the 9900 with the 2850 Sensor Electronics Thread styles are reversible threads or fixed threads MFR # Cell Constant (cm ¹) Electrode Process Connection Part No. USD SST Threaded C SST Threaded S SST Threaded S1C SST Threaded S SST Threaded , S2C SST Threaded , T1 1 Titanium 1.5 inch flange , T1C 1 Titanium 1.5 inch flange , T2 1 Titanium 1.5 inch flange , T2C 1 Titanium 1.5 inch flange ,

51 Type 2822/2823 Conductivity/Resistivity Electrode Conductivity/Resistivity: Wetted Materials: 316 SST or Titanium Process Connection Choices: 3/4 inch threads for In-line or Submersion, 1.5 inch Sanitary Triclamp flange and 2 inch Sanitary Tri-clamp flange Cell constants and corresponding measuring ranges: 0.01 cm-1 / 0.55 to 100 μs (18.3 mω to 10 KΩ)0.1 cm-1 / 1 to 1000 μs (1 mω to 1 KΩ)1.0 cm-1 / 10 to 10,000 μs (5 to 5,000 ppm)10.0 cm-1 / 100 to 200,000 μs (50 to 100,000 ppm)20.0 cm-1 / 200 to 400,000 μs (100 to 200,000 ppm) Compatible Instruments: Signet Instrument Types: 8850, or the 9900 with the 2850 Sensor Electronics Additional Features: (2823) Thread is reversible for submersion mounting MFR # Cell Constant (cm ¹) Electrode Part No. USD SST SST Type V(D) to V(D) PVDF Conductivity Electrodes Conductivity/Resistivity: ± 2% accuracy - Custom calibration certificate provided Dual-threaded Compact electrode length for easy in-line installation in small pipe sizes Triple orifice flow-through design reduces clogging and bubble entrapment 316 SS electrodes with injection molded PVDF process connections and insulators Meets USP requirements MFR # Cell Constant (cm ¹) Connection Thread size Cable Length Part No. USD V 0.01 Dual threaded ¾ inch NPT 4.6 m (15 ft) VD 0.01 Dual threaded ISO 7/1-R 3/4 4.6 m (15 ft) V 0.10 Dual threaded ¾ inch NPT 4.6 m (15 ft) VD 0.10 Dual threaded ISO 7/1-R 3/4 4.6 m (15 ft) V 1.00 Dual threaded ¾ inch NPT 4.6 m (15 ft) VD 1.00 Dual threaded ISO 7/1-R 3/4 4.6 m (15 ft) V Dual threaded ¾ inch NPT 4.6 m (15 ft) VD Dual threaded ISO 7/1-R 3/4 4.6 m (15 ft) Type 2850 Conductivity/Resistivity Sensor Electronics Conductivity/Resistivity: Accepts any cell constant Compatible with all Signet Conductivity Sensors Output choices include digital (S 3 L) for use with the Signet 8900, 9900, 9950 or 4 to 20mA Compatible with Signet Instrument Type 8900 or instruments accepting a 4 to 20mA output Single or dual input available for remote mount version (S3L) only MFR # Mounting Output Part No. USD /4 inch FNPT Digital (S3L), one input /4 inch FNPT 4-20mA, one input Universal Mount Digital (S3L), one input Universal Mount 4-20mA, one input Universal Mount Digital (S3L), one or two inputs

52 Type 2850 Conductivity/Resistivity Integral Systems PVDF Conductivity/Resistivity: Test certificate supplied with all sensors Custom cell constant programmed into the electronics Integral mount systems for quick and easy installation Extends the distance between the measuring point and the 9900 Transmitter to 120m (400ft) EasyCal with automatic test solution recognition Dual channel unit available for low cost installation with Signet 8900 Multi-Parameter Controller For use with ALL Signet conductivity electrodes MFR # Process Connection Cell Constant (cm ¹) Output Part No. USD V NPT 0.01 Digital (S3L) V NPT 0.10 Digital (S3L) V NPT 1.00 Digital (S3L) V NPT Digital (S3L) VD ISO 0.01 Digital (S3L) VD ISO 0.10 Digital (S3L) VD ISO 1.00 Digital (S3L) VD ISO Digital (S3L) V NPT to 20 ma V NPT to 20 ma V NPT to 20 ma V NPT to 20 ma , VD ISO to 20 ma VD ISO to 20 ma VD ISO to 20 ma VD ISO to 20 ma ,

53 Temperature, Pressure, Level Submersible Hydrostatic Pressure Sensor Type 2250 For Level and Depth Control 1/2 inch union connector Temperature/Pressure: Cable Length: 10 m (32.8 ft) Operating Temperature: ** 15 to 85 C (5 to 185 F) Operating Pressures:** -XU Ultra Low: 0 to 0.7 bar (0 to 10 psi) -XL Low: 0 to 3.4 bar (0 to 50 psi) Compatibility: 8450, 8900 and 9900 MFR # Output Maximum Operation Part No. USD U Digital (S³L) 0.7 bar (10 psi); 7.03 m (23 ft) L Digital (S³L) 3.4 bar (50 psi); m (115 ft) U 4-20 ma 0.7 bar (10 psi); 7.03 m (23 ft) L 4-20 ma 3.4 bar (50 psi); m (115 ft) U-1 Digital (S³L) 0.7 bar (10 psi); 7.03 m (23 ft) L-1 Digital (S³L) 3.4 bar (50 psi); m (115 ft) U ma 0.7 bar (10 psi); 7.03 m (23 ft) L ma 3.4 bar (50 psi); m (115 ft) Temperature/Pressure Sensors Type 2350 Temperature Sensor Temperature/Pressure: Wetted Materials: PDVF Additional features: Platinum RTD in extended tip for quick response In-line Mounting styles: 3/4 inch NPT Submersible mounting: 3/4 inch NPT Operating Temperature:** In-line: -10 to 100 C (14 to 212 F) Submersible: -10 to 85 C (14 to 185 F) Operating Pressures:** 0 to 16 bar (0 to 232 psi) Compatibility: 8350, 8900 or 9900 **check operating temperature/pressure graphs in catalog for derating information MFR # Output Cable Length Part No. USD Digital (S³L) 4.6m (15 ft.) ma 4.6m (15 ft.)

54 Type 2450 Pressure Sensor 1/2 inch male union Temperature/Pressure: Wetted Materials: PVDF, ceramic, FKM 4 to 20 ma or digital (S3L) output in-line Mounting styles: 1/2 inch male union Operating Temperature: ** 15 to 85 C (5 to 185 F) Operating Pressures:**-XU Ultra Low: 0 to 0.7 bar (0 to 10 psi)-xl Low: 0 to 3.4 bar (0 to 50 psi)- XH High: 0 to 17 bar (0 to 250 psi) Compatibility: 8450, 8900 and 9900 *Level ranges calculated using specific gravity of water. Maximum ranges may vary for other liquids **check operating temperature/pressure graphs in catalog for derating information MFR # Output Maximum Operation Cable Length Part No. USD U Digital (S³L) 0.7 bar (10 psi) 4.6m (15 ft.) L Digital (S³L) 3.4 bar (50 psi) 4.6m (15 ft.) H Digital (S³L) 17 bar (250 psi) 4.6m (15 ft.) U 4-20 ma 0.7 bar (10 psi) 4.6m (15 ft.) L 4-20 ma 3.4 bar (50 psi) 4.6m (15 ft.) H 4-20 ma 17 bar (250 psi) 4.6m (15 ft.) B Union nut Size d PVC USD CPVC USD ABS USD Part No. Part No. Part No Call Call Call PP-H USD PVDF USD Part No. Part No Call Call Call Call Call Call 50

55 Radar and Ultrasonic Level Sensors/- Transmitters Continuous Level 2290 EX-Types Non-Contacting Radar Remark: Display: LCD MFR # Measuring range (m) Connection Sensor Type 2290-P-1DN2X /2" NPT PP 2290-S-DN2X /2" NPT SS316/DIN MFR # Part No. USD SP weight (kg) 2290-P-1DN2X Call S-DN2X Call Non-EX Non-Contacting Radar Remark: Display: LCD MFR # Measuring range (m) Connection Sensor Type 2290-P-1DN /2" NPT PP 2290-S-DN /2" NPT SS316/DIN F-DN /2" NPT PTFE MFR # Part No. USD SP weight (kg) 2290-P-1DN , S-DN , F-DN , EX-types Contacting Radar (TDR) Remark: Display: LCD Sensor Type: SS316/DIN , rope/rod MFR # Description Measuring range (m) Connection 2291-S-1DN1X-6-R 6m cable, Ø 4mm " NPT 2291-S-1DN1X-2-D 2m rod, Ø 8mm " NPT MFR # Part No. USD SP weight (kg) 2291-S-1DN1X-6-R Call S-1DN1X-2-D Call

56 2291 Contacting Radar (TDR) Remark: Display: LCD Sensor Type: SS316/DIN , rope/rod MFR # Description Connection Part No. USD SP weight (kg) 2291-S-1DN1-6-R 6m cable, Ø 4mm 1" NPT , S-1DN1-2-D 2m rod, Ø 8mm 1" NPT , Accessories for 2290 MFR # Connection Sensor Type Part No. USD SP weight (kg) 2290-F-ENC-B2 1 1/2" BSP PTFE Call F-ENC-N2 1 1/2" NPT PTFE Type 2260 Level Transmitter Type 2260 Level Transmitter, Continuous Measuring, Display Version, 4-20 ma / HART, ATEX approval Principle: non-contact ultrasonic transit time Measuring range: m, m, m Sensor Type: PVDF Output: 4-20 ma, 2-wire; HART Protocol Integrated display and programming buttons Supply power: V DC ATEX II 1 EEx ia II B T6 MFR # Measuring range (m) Sensor Type Part No. USD weight (kg) Process Connection 2260-V-1DNX /2" NPT PVDF , V-1DNX " NPT PVDF , ANSI Flange V-1DAX-15 inch PVDF ,

57 Type 2260 Level Transmitter, Continuous Measuring, Display Version, 4-20 ma Output Principle: non-contact ultrasonic transit time Measuring range: m, m, m Sensor Type: PP or PVDF Output: 4-20 ma, 2-wire Integrated display and programming buttons Supply power: V DC MFR # Measuring range (m) Process Connection Sensor Type Part No. USD weight (kg) 2260-P-0DN /2" NPT PP , P-0DN " NPT PP , P-0DA ANSI Flange 5 inch PP , V-0DN /2" NPT PVDF , V-0DN " NPT PVDF , V-0DA ANSI Flange 5 inch PVDF , Type 2260 Level Transmitter, Continuous Measuring, Display Version, 4-20 ma / HART / Relay Output Principle: non-contact ultrasonic transit time Measuring range: m, m, m Sensor Type: PP or PVDF Output: 4-20 ma, 2-wire; HART Protocol; Relay Integrated display and programming buttons Supply power: V DC MFR # Measuring range (m) Process Connection Sensor Type Part No. USD weight (kg) 2260-V-2DN /2" NPT PP , V-2DN " NPT PP , P-2DA ANSI Flange 5 inch PP , V-2DN /2" NPT PVDF , V-2DN " NPT PVDF , P-2DA ANSI Flange 5 inch PVDF , Accessories for 2260 Description Part No. USD HART-USB Modem HART-USB Modem, DIN Rail HART-USB Modem, DIN Rail, ATEX Display unit for type 2260 Transmitter

58 Type 2270 Level Sensors, Continuous Measuring, Blind Version, 4-20 ma / HART Output Principle: non-contact ultrasonic transit time Measuring range: m, m Sensor Type: PP or PVDF Output: 4-20 ma, 2-wire; HART Protocol Supply power: V DC MFR # Measuring range (m) Process Connection Sensor Type Part No. USD weight (kg) 2270-P-1N /2" NPT PP P-1N " NPT PP V-1N /2" NPT PVDF V-1N " NPT PVDF Point Level Switches 2280 Swing Forks - PBT Enclosure, Relay Output Vibrating Principle Output Type: 1 SDPT relay Switching Function: 1 SDPT relay Sensor body: Stainless Steel Power Supply: V AC and V DC Connection: Terminal Process Connection MFR # Length S-5WBT S-5WBT S-5WNT S-5WNT-2 Part No. USD 69 1" BSP " BSP " NPT " NPT

59 2280 Swing Forks, Cable/DIN Connectors, PNP/NPN/2-Wire Vibrating Principle Sensor body: Stainless Steel Switching Function: 2-wire AC; 3-wire PNP-NPN Power Supply: V DC or V AC, 50/60 HZ Connection: Cable PVC 5x0.5mm2, 3m or DIN Connector Process Connection MFR # Length S-5WBO S-5WBC S-5WBO S-5WBC S-5XWBO S-5XWBC S-5XWB S-5XWBC S-5WNO S-5WNC S-5WNO S-5WNC S-5XWNO S-5XWNC S-5XWNO S-5XWNC-2 Approvals Connection Part No. USD 69 1" BSP DIN Connector " BSP Cable " BSP DIN Connector " BSP Cable " BSP ATEX DIN Connector " BSP ATEX Cable , " BSP ATEX DIN Connector , " BSP ATEX Cable , " NPT DIN Connector " NPT Cable " NPT DIN Connector " NPT Cable " NPT ATEX DIN Connector " NPT ATEX Cable , " NPT ATEX DIN Connector , " NPT ATEX Cable , Swing Forks, Cable/DIN Connectors, PNP/NPN/2-Wire, ATEX Vibrating Principle Sensor body: Stainless Steel Switching Function: 2-wire AC; 3-wire PNP-NPN Power Supply: V DC or V AC, 50/60 HZ Connection: Cable PVC 5x0.5mm2, 3m or DIN Connector Process Connection MFR # Length S-5XWBO S-5XWBC S-5XWB S-5XWBC S-5XWNO S-5XWNC S-5XWNO S-5XWNC-2 Approvals Connection Part No. USD 69 1" BSP ATEX DIN Connector " BSP ATEX Cable , " BSP ATEX DIN Connector , " BSP ATEX Cable , " NPT ATEX DIN Connector " NPT ATEX Cable , " NPT ATEX DIN Connector , " NPT ATEX Cable ,

60 2281 Multipoint Switch, 1 or 2 SPDT Relay, 2-4 Electrodes Conductive Principle Relay Output: 1 or 2 SPDT Power Supply: 24V 240V AC or DC 24V AC/DC Max. voltage rating 250V AC1, 24V DC Probes: 2,3,4 + 1 Reference Electrode Material: Stainless Steel Electrode Length: 0.5, 1.0, 1.5 m (max. 3 m) Electrode Seperator, Material PP ( KLP-201) MFR # Length Process Connection Sensor Type Part No. USD 2281-S-BT-2 1 1/2" BSP S-BT-3 1 1/2" BSP S-BT-4 1 1/2" BSP KLN m Stainless Steel KLN m Stainless Steel KLN m Stainless Steel KLP Relay Relay uided Float Switch, Reed contact, Cable, PP/PVDF Output: Reed Contact Connection: Cable Cable Type: AW30, 2-core, PVC, 1m Contact Components: N/O or N/C depending on the installation MFR # Process Connection Sensor Type Part No. USD 2282-P-6CB 1/2" BSP PP V-6CB 1/2" BSP PVDF P-6CN 1/2" NPT PP V-6CN 1/2" NPT PVDF Ultrasonic ap Switch, Relay Output, PPS body Ultrasonic Principle Power Supply: 18 to 30 VDC / AC Switching Function: SPCO Relay NO/NC Sensor body: PPS Max. Voltage Rating: 30 VDC / AC Cable Type: 5-core 7/0.2mm, 3m MFR # Process Connection Part No. USD 2284-Q-4BC BSP-T 3/4" Q-4NC NPT 1" Q-4BC BSP-T 1"

61 2285 Float Switch, NO/NC, PP body Microswitch: SPDT 250V AC, 3A NO/NC Sensor body: PP Ingress Protection: IP 68 Switching Angle: 45 Separate counterweight MFR # Cable length (m) Part No. USD 2285-P-6C P-6C P-6C P-weight

62 Other Products Analytical Sensor Accessories and Replacement Part ph/orp Electrode Mounting P P200 P C200 P V200 P31542 P MFR # Description For Type Part No. USD PVC Pipe 2724, 2725, Adapter, 1.25 * in. o.d. CPVC Pipe Adapter, 1.25 in. o.d. PVDF Pipe Adapter, 1.25 in. o.d. Sensor Cap, Blue Sensor Cap, Blue 2724, 2725, , 2725, 2726 * * ph/orp Miscellaneous MFR # Description Part No. USD O-ring, FKM (2 req'd per sensor) O-ring, EPR (EPDM) (2 req'd per sensor) O-ring, FFPM (2 req'd per sensor Cable, 24 AW, 6-conductor Preamplifier Replacement Salt Bridge * Replacement Reference * PVC-C Adapter, SS (1.4401) Adapter, Calibration kit, 3 PP cups, 1 pt ea 4, 7 solu * gm bottle Quinhydrone for ORP calibration * Connects directly to instrument Use with DryLoc preamplifiers ph buffer kit (1 ea 4, 7, 10 powder form) * ph 4 buffer solution, 1 pt (473 ml) * ph 7 buffer solution, 1 pt (473 ml) * ph 10 buffer solution, 1 pt (473 ml) * Cable, 3cond. plus shield, 22 AW, black/red Retaining nut replacement kit, Valox K hour heat pack Wet-Tap Replacement Parts MFR # Description For Part No. USD Type O-ring, FKM Locking Shroud O-ring, FKM

63 Miscellaneous MFR # Description Part No. USD /4 in. NPT fitting, 316SS Cable (2 Conductors, shield) /2 in. NPT fitting, 316SS Replacement Insulator Universal Junction Box with EasyCal /4 in. NPT Junction Box with EasyCal DIN Rail (1m length) End Clips for DIN Rail Cable (2 Conductor, shield) Universal Mount Junction Box Retaining nut replacement kit, Valox K Cable, 3cond. plus shield, 22 AW, black/red Universal junction box, conductivity electrodes, digital (S3L) output Universal junction box, conductivity electrodes, 4 to 20 output Universal In-line Sensor Adapter Description Part No. USD Universal In- Line Sensor Adapter Buffer Solutions for ph/orp Buffer Solutions ph/orp: NIST Traceable Temperature compensated values Liquid or powder versions Kits available for easy use Easily identifable color coded buffer solutions MFR # Description Part No. USD ph 4 buffer solution, 1 pt (473 ml) * ph 7 buffer solution, 1 pt (473 ml) * ph 10 buffer solution, 1 pt (473 ml) * ph buffer kit (1 ea 4, 7, 10 powder form) * Calibration kit, 3 PP cups, 1 pt ea 4, 7 solu * gm bottle Quinhydrone for ORP calibration *

64 ph/orp System Tester Type 2759 ph/orp System Tester ph/orp: Connects to any Signet ph/orp instrument Compatible with 2750 and 2760 preamplifiers Additional Features: Battery powered millivolt generator Simulated ph or ORP values Verifies system functionality MFR # Description Compatible Preamplifier Part No. USD Connects directly to instrument n/a Use with DryLoc preamplifiers 2750, 2760 DryLoc Conductivity/Resistivity Tools Conductivity/Resistivity Tools Conductivity/Resistivity: NIST traceable units Available in five different values Simulates various values to validate or calibrate instruments and sensor electronics 2850 tools are temperature compensated to 25C for various conductivity or resistive values Verifies electronics independent of electrode Compatible with all Signet Conductivity/Resistivity instruments MFR # Input Simulated Part No. USD μs μs μs MΩ MΩ Configuration Tool Back up and restore 9900 Transmitter configurations to a computer file User-Friendly Interface Configure settings such as instrument type, units and modify labels from the computer Use a single file to clone multiple 9900 Transmitters Red and blue LED indicators for data and power MFR # Description Part No. USD Configuration Tool

65 Switching Power Supplies 7310 Switching Power Supplies Universal A/C input/full range Protections: Short circuit/overload/over-voltage Cooling by free air convection Install on DIN rail TS-35/7.5 or 15 NEC class 2 / LPS compliant Built-in DC OK active signal LED indicator for power on MFR # Description Part No. USD VDC Power Supply, 10W, 0.42 A VDC Power Supply, 24W, 1.0 A VDC Power Supply, 40W, 1.7 A VDC Power Supply, 60W, 2.5 A VDC Power Supply, 96W, 4.0 A Relay 8059 External Relay Modules Instruments: Relay Outputs: 2 or 4 external contact relays. SPDT 250VAC/30VDC/5A Operating Temperature: -10 C to 55 C (14 F to 131 F) Relative Humidity: 0 to 90% (non-condensing) Pass-through Output: S3L signals can be passed through this unit Material: Enclosure: Noryl UL 94 V-O Compatible Instruments: 8900 (S3L Instruments only) MFR # Description Part No. USD Four external dry-contact relays AC Four external dry-contact relays with power supply

66 Installation and Weld-on Fittings Plastic Installation Fittings PVC TEES SCH 80 - Fitting only Type Size L H i.d. Sensor Type Part No. USD MPV8T005F Flow -X0, ph-xx MPV8T007F Flow -X0, ph-xx MPV8T010F Flow -X0, ph-xx MPV8T012F Flow -X0, ph-xx MPV8T015F Flow -X0, ph-xx MPV8T020F PVC TEES SCH 80 - with pipe Type Size L H o.d. Sensor Type Part No. USD MPV8T Flow -X0, ph-xx MPV8T Flow -X0, ph-xx MPV8T Flow -X0, ph-xx MPV8T Flow -X0, ph-xx MPV8T Flow -X0, ph-xx MPV8T Flow -X0, ph-xx PVC TEES SCH inch with pipe Part No. Size L H o.d. Sensor Type Part No. USD PV8T Flow-X0, ph-xx PV8T Flow-X0, ph-xx PV8T Flow-X0, ph-xx PVC Clamp-on Saddles SCH 80 Mounts on PVC pipe C - Clearance dimension EPDM O-ring Type Size L H d C Sensor Type Part No. USD PV8S Flow -X0, ph-xx PV8S Flow -X0, ph-xx PV8S Flow -X0, ph-xx PV8S Flow -X PV8S Flow -X PV8S Flow -X

67 PVC lue-on Saddle Type Size W H o.d. C Sensor Type Part No. USD PV8S Flow -X PV8S Flow -X CPVC TEES SCH 80 - Fitting only Type Size L H i.d. Sensor Type Part No. USD MCPV8T005F Flow -X0, ph -XX MCPV8T007F Flow -X0, ph -XX MCPV8T010F Flow -X0, ph -XX MCPV8T012F Flow -X0, ph -XX MCPV8T015F Flow -X0, ph -XX MCPV8T020F Flow -X0, ph -XX CPVC TEES SCH 80 - with pipe* Type Size L H o.d. Sensor Type Part No. USD MCPV8T Flow -X0, ph -XX MCPV8T Flow -X0, ph -XX MCPV8T Flow -X0, ph -XX MCPV8T Flow -X0, ph -XX MCPV8T Flow -X0, ph -XX MCPV8T Flow -X0, ph -XX Fiberglass lue-on Tees PVDF insert - all sizes PTFE tapewetted material. Consult factory for available options. Type Size L H i.d. Sensor Type Part No. USD FPT Flow -X0, ph -XX * FPT Flow -X0, ph -XX *

68 Plastic Installation Fittings (metric) BSP PVC Tee Fittings FKM O-ring These fittings are only available from your local eorg Fischer sales office Type d d FKM Part No. USD EPDM Part No. USD L L1 H PVAT Call Call PVAT Call Call PVAT Call Call PVAT Call Call PVAT Call Call PVAT Call Call BSP PVC Clamp-on Saddle EPDM asket These fittings are only available from your local eorg Fischer sales office Type d Size D H H1 L Part No. USD PVAS Call PVAS Call PVAS Call Metric PVC Tee Type d DN L L1 H FKM USD EPDM USD Part No. Part No. PVMT Call Call PVMT Call Call PVMT Call Call PVMT Call Call PVMT Call Call PVMT Call Call 64

69 Metric PP Union Tee Socket fusion equipment is required to install PVDF and PP union tees. FKM O-ring Type d DN Sensor Type FKM USD EPDM USD Part No. Part No. PPMT flow X0, ph XX Call PPMT flow X0, ph XX Call PPMT flow X0, ph XX Call PPMT flow X0, ph XX Call PPMT flow X0, ph XX Call PPMT flow X0, ph XX Call L L1 H Instrument Installation Fitting Type 310 (FKM black) PN 16, Standard PVDF Range of use: Compatible Signet ph/orp sensors: models 2724, 2725, 2726 Compatible Signet flow sensors: models 2551, 2537, 515, 8510, 2536, 8512 Model: Union end with fusion socket PVDF Material: PVDF Threaded outlet 1 ¼" NPSM Supplied with o-rings Attention: Sensor length depends on installation fitting d PN (bar) Part No. USD SP L1 D H L z Sensor Type flow X0, ph XX flow X0, ph XX flow X0, ph XX flow X0, ph XX flow X0, ph XX flow X0, ph XX 65

70 Instrumentation Installation Fitting Type 311, Standard PP Range of use: Compatible Signet flow sensors: models 2551, 2537, 515, 8510, 2536, 8512 Attention: Sensor length depends on installation fitting Model: Material: PP-H Threaded outlet 1 ¼" NPSM Suitable for backing flanges metric and inch Suitable for SDR 11 - SDR 17.6 Delivered with profile O-ring d d PN DN EPDM USD FKM USD (bar) Part No. Part No Call Call Call Call Call Call Call Call Call Call Call Call Call Call Call Call Call Call Call d D L1 L H Sensor Type flow X flow X flow X flow X flow X flow X flow X flow X flow X flow X flow X flow X2 66

71 Instrument Installation Fitting Type 311 (FKM black), Standard PVDF Range of use: Compatible Signet flow sensors: models 2551, 2537, 515, 8510, 2536, 8512 Attention: Sensor length depends on installation fitting Model: Material: PVDF Threaded outlet 1 ¼" NPSM Suitable for backing flanges metric and inch Delivered with profile O-ring d DN PN (bar) d Part No. USD SP Sensor Type D H L L Call 0 flow X , flow X Call 0 flow X Call 0 flow X Call 0 flow X Call 0 flow X Call 0 flow X Call 0 flow X Metal Fittings Carbon Steel Threaded Tees with NPT Thread PVDF insert - all sizes For use with SCH 40 metal pipe (ASTM) PTFE tapewetted material. Consult factory for available options. Type Size L H Sensor Type Part No. USD CS4T Flow -X0, ph -XX CS4T Flow -X0, ph -XX CS4T Flow -X0, ph -XX CS4T Flow -X0, ph -XX CS4T Flow -X0, ph -XX CS4T Flow -X0, ph -XX

72 Copper Sweat-on Tee with PVDF Insert No insert up to 1 in., over 1 in. - PVDF insert For use with copper pipe (SCH K) PTFE tapewetted material. Consult factory for available options. Type Size L H i.d. Sensor Type Part No. USD CUKT Flow -X0, ph -XX CUKT Flow -X0, ph -XX CUKT Flow -X0, ph -XX CUKT Flow -X0, ph -XX CUKT Flow -X0, ph -XX CUKT Flow -X0, ph -XX alvanized Iron Threaded Tee with NPT Threads and PVDF Insert PVDF insert - all sizes For use with SCH 40 metal pipe (ASTM) PTFE tapewetted material. Consult factory for available options. Type Size NPT L H Sensor Type Part No. USD IR4T Flow -X0, ph -XX IR4T Flow -X0, ph -XX IR4T Flow -X0, ph -XX IR4T Flow -X0, ph -XX SS (1.4401) Threaded Tees with NPT Threads with PVDF Insert For use with SCH 40 metal pipe (ASTM) PTFE tapewetted material. Consult factory for available options. PVDF insert - all sizes Type Size L H Sensor Type Part No. USD CR4T Flow -X0, ph -XX CR4T Flow -X0, ph -XX CR4T Flow -X0, ph -XX CR4T Flow -X0, ph -XX CR4T Flow -X0, ph -XX CR4T Flow -X0, ph -XX

73 Brass Threaded Tee with NPT Threads and PVDF Insert PVDF insert - all sizes For use with SCH 40 metal pipe (ASTM) PTFE tapewetted material. Consult factory for available options. Type Size NPT L H Sensor Type Part No. USD BR4T Flow -X0, ph -XX BR4T Flow -X0, ph -XX BR4T Flow -X0, ph -XX BR4T Flow -X0, ph -XX Carbon Steel Weld-on Weldolets with PVDF Insert For use with SCH 40 metal pipe (ASTM) PTFE tapewetted material. Consult factory for available options. C - Clearance dimension Up to 8 in. - PVDF insert, over 8 in. - PVC insert Type Size H W C Sensor Part No. USD Type CS4W Flow -X0, ph -XX CS4W Flow -X0, ph -XX CS4W Flow -X0, ph -XX CS4W Flow -X CS4W Flow -X CS4W Flow -X CS4W Flow -X CS4W Flow -X

74 Brass Brazolet with PVDF insert C - Clearance dimension PTFE tapewetted material. Consult factory for available options. Up to 8 in. - PVDF insert, over 8 in. - PVC insert Type Size W H C Sensor Part No. USD Type BR4B Flow -X0, ph -XX BR4B Flow -X0, ph -XX BR4B Flow -X0, ph -XX BR4B Flow -X BR4B Flow -X BR4B Flow -X BR4B Flow -X2 * BR4B Flow -X2 * SS (1.4401) Weldolets with PVDF Insert C - Clearance dimension Up to 8 in. - PVDF insert, over 8 in. - PVC insert For use with SCH 40 metal pipe (ASTM) PTFE tapewetted material. Consult factory for available options. Type Size W H C Part No. USD CR4W CR4W CR4W CR4W CR4W CR4W CR4W CR4W

75 Iron Strap-on Saddle Up to 8 in. - PVDF insert, over 8 in. - PVC insert C - Clearance dimension Buna Nitrile O-ring For use with SCH 80 & 40 metal pipe (ASTM) PTFE tapewetted material. Consult factory for available options. Type Size H o.d. min o.d. max C Sensor Part No. USD Type IR8S Flow -X0, ph -XX IR8S Flow -X0, ph -XX IR8S Flow -X0, ph -XX IR8S Flow -X0, ph -XX IR8S Flow -X IR8S Flow -X R8S Flow -X IR8S Flow -X IR8S Flow -X Metalex Weld-on Mini-Tap (1.4401) For use with SS pipe asket Klinger C4401 Thermoseal Type DN Size for sensor Part No. USD W H C P P525-2, 2S P P525-2, 2S P P525-2, 2S P P525-2, 2S P P525-2, 2S P P525-2, 2S P P525-2, 2S P P525-2, 2S P P525-2, 2S P P525-2, 2S P P525-2, 2S Metalex Socket Weld Mini-Tap (1.4401) For use with SS pipe Type DN Size for sensor Part No. USD L W H i.d. P P525-1, 1S P P525-1, 1S P P525-1, 1S

76 Electrofusion Fittings Transition Saddles for Stainless Steel 1¼ Outlet Size L H Sensor Part No. USD Type Call Transition Saddles for Stainless Steel 1½ Outlet Size L H Sensor Part No. USD Type , 2540-XX, , 2540-XX, , 2540-XX, , 2540-XX, , 2540-XX, PE Socket Fusion X Threaded Transition Fitting Size Process Connection Sensor Type Part No. USD

Signet Measurement and Instrumentation

Signet Measurement and Instrumentation F Piping Systems Signet Measurement and Instrumentation Price List effective January 1, 2015 Conveyance Pipe, Fittings, Joining Technology // PVC/CPVC // PPro-Seal PP // PROEF PP // SYEF PVDF // Contain-It

More information

Signet 2536 Rotor-X Paddlewheel Flow Sensors

Signet 2536 Rotor-X Paddlewheel Flow Sensors Signet 2536 Rotor-X Paddlewheel Flow s Features Operating range 0.1 to 6 m/s (0.3 to 20 ft/s) Wide turndown ratio of 66:1 Open-collector output Highly repeatable output Simple, economical design PVC (gray

More information

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 515 Rotor-X Paddlewheel Flow Sensors Signet 515 Rotor-X Paddlewheel Flow Sensors Features Operating range 0.3 to 6 m/s (1 to 20 ft/s) Wide turndown ratio of 20:1 Highly repeatable output Simple, economical design Installs into pipe sizes

More information

Signet 515 Rotor-X Paddlewheel Flow Sensors

Signet 515 Rotor-X Paddlewheel Flow Sensors Signet 515 Rotor-X Paddlewheel Flow Sensors Features Operating range 0.3 to 6 m/s (1 to 20 ft/s) Wide turndown ratio of 20:1 Highly repeatable output Simple, economical design Installs into pipe sizes

More information

Automation Made Easy 2013 Signet Measurement and Control Product Catalog

Automation Made Easy 2013 Signet Measurement and Control Product Catalog Multi-Parameter Chlorine Dissolved Oxygen Turbidity Flow ph/orp Conductivity/Resistivity Temperature Pressure Level Automation Made Easy 2013 Signet Measurement and Control Product Catalog Automation Made

More information

2100 Turbine Flow Sensor

2100 Turbine Flow Sensor 200 Turbine Flow Sensor Description Engineered specifically for small pipe diameter applications, the Signet 200 Turbine Flow Sensor provides accurate readings in two flow ranges: 0.3 to 3.8 lpm and 3

More information

Signet 2551 Magmeter Flow Sensor

Signet 2551 Magmeter Flow Sensor Signet 2551 Magmeter Flow Sensor Available in a variety of wetted materials and ideal for pipe sizes up to DN900 (36 in.) Features Test certificate included for -X0, -X1 Patented Magmeter technology No

More information

GF Signet. Measurement & Control Sensors. Signet Price List 1st Aug 2011 Rev 0.0

GF Signet. Measurement & Control Sensors. Signet Price List 1st Aug 2011 Rev 0.0 GF Signet Measurement & Control Sensors Sensors and Transmitters: Flow ph Conductivity ORP Level Pressure Temperature Turbidity Chlorine Installation fittings Power supplies Calibration solutions Accessories

More information

Signet 3719 ph/orp Wet-Tap Assembly

Signet 3719 ph/orp Wet-Tap Assembly Signet 3719 ph/p Wet-Tap Assembly Features Electrode removal without process shutdown Space saving 45 mm (1.75 in.) short-stroke design Sealed pneumatic dampening for smooth and safe operation SafeLoc

More information

Signet Conductivity/Resistivity Electrodes

Signet Conductivity/Resistivity Electrodes Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 in. - Opt. ½ in.

More information

Measurement & Instrumentation 2005 Product Catalog on CD. Creating Quality by Connecting Technology to Life. Click on image to begin.

Measurement & Instrumentation 2005 Product Catalog on CD. Creating Quality by Connecting Technology to Life. Click on image to begin. Measurement & Instrumentation 2005 Product Catalog on CD Creating Quality by Connecting Technology to Life Click on image to begin. Main Contents Measurement & Instrumentation 2005 Product Catalog Flow

More information

Signet Conductivity/Resistivity Electrodes

Signet Conductivity/Resistivity Electrodes Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 - Opt. ½ in. NPT

More information

Signet DryLoc ph/orp Electrodes

Signet DryLoc ph/orp Electrodes Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature

More information

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors

Signet 2760 DryLoc ph/orp Preamplifiers & Connectors Signet 2760 DryLoc ph/orp Preamplifiers & Connectors Features In-line integral mount and submersible installation versions Automatic temperature compensation Auto configuration for ph or ORP operation

More information

* * Rev. 9 01/18 Product Manual

* * Rev. 9 01/18 Product Manual English Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. 9 01/18 Product Manual Description The Signet 2760 ph/orp Preamplifiers with DryLoc connectors are part of Signet's growing line

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Glass Protected Bulb Patented reference design for exceptional performance * Mounts in Signet standard fittings

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½

More information

Product Specifications

Product Specifications SYGEF Plus PVDF HP Metric Piping System Specification 1. Scope This specification covers requirements for the +GF+ Georg Fischer (later named only +GF+) SYGEF Plus PVDF HP Piping System intended for a

More information

Signet DryLoc ph/orp Electrodes

Signet DryLoc ph/orp Electrodes Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature

More information

Instrument Enclosure Assemblies

Instrument Enclosure Assemblies Instrument Enclosure Assemblies Standard instrument enclosure Instrument enclosures offer a simple solution for the customer who doesn t have the time to install Signet meters into panels. Whether it s

More information

Signet 2760 DryLoc ph/orp Preamplifier

Signet 2760 DryLoc ph/orp Preamplifier Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. H 05/11 English English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility

More information

Electromagnetic Flowmeters. Product Overview.

Electromagnetic Flowmeters. Product Overview. Electromagnetic Flowmeters Product Overview www.lcmeter.com Premier products, premier performance Liquid Controls offers a broad selection of electromagnetic (Mag) flow meters for industrial and water

More information

SIGNET 2760 DryLoc ph/orp Preamplifier

SIGNET 2760 DryLoc ph/orp Preamplifier SIGNET 2760 DryLoc ph/orp Preamplifier 3-2760.090 3-2760.090 (A-3/04) English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confirm chemical compatibility before

More information

Signet 515/2536 Rotor-X Flow Sensors * * Operating Instructions. English. Description Rev. X 05/17

Signet 515/2536 Rotor-X Flow Sensors * * Operating Instructions. English. Description Rev. X 05/17 English Signet 515/2536 Rotor-X Flow Sensors *3-0515.090* 3-0515.090 Rev. X 05/17 Operating Instructions 515 Sensor (with red cap) 2536 Sensor (with blue cap) 8510 Integral Sensor 8512 Integral Sensor

More information

Product Specifications

Product Specifications PE 100 Metric Piping System Specifications 1. Scope This specification covers requirements for the +GF+ Georg Fischer (later named only +GF+) PE 100 Piping System intended for a wide range of applications

More information

MEASUREMENT AND INSTRUMENTATION FLS

MEASUREMENT AND INSTRUMENTATION FLS MEASUREMENT AND INSTRUMENTATION FLS The FLS Measurement and Instrumentation line consists of a comprehensive range of Flow, ph, ORP, Conductivity Sensors, Monitors and Transmitters. INDEX SYSTEM SELECTION

More information

G2 Industrial Grade Meters

G2 Industrial Grade Meters G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine

More information

Measurement and Instrumentation

Measurement and Instrumentation 15 Measurement and Instrumentation Use the postcard included in this handbook or call (800) 854-4090 to order the complete Instrumentation Catalog or visit www.gfsignet.com for detailed product information.

More information

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading. Analogue Flow Rate Indicator, DN 15...; PN 1...16 Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a large

More information

magnetic flow meters Johannesburg (Head Office) Technical Data Safmag Wafer Type

magnetic flow meters Johannesburg (Head Office) Technical Data Safmag Wafer Type magnetic flow meters Safmag Flanged Type Lining Electrodes Accuracy 25mm to 800mm Natural rubber Neoprene Ebonite Polyurethane PTFE Hastelloy C Monel Titanium Tantalum Conductive rubber 110 / 220 V AC

More information

A1 Commercial Grade Meters

A1 Commercial Grade Meters A1 Commercial Grade Meters Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters come in Aluminum or Nylon only. A1 Meters are not field serviceable like

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2734-2736 ph/orp Electrodes Compatible with Signet 8900/9900 Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½

More information

PSF50 Paddle flow switch

PSF50 Paddle flow switch Paddle Flow Switch Paddle Flow Switch PSF50 Paddle flow switch Paddle flap flow / no flow switch Economically priced flow/no flow paddle operated flow switch. Simple and reliable design for liquids up

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011 Product Data Sheet PDS 71-400/rev.J January 2011 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

G2 SERIES INDUSTRIAL GRADE METERS

G2 SERIES INDUSTRIAL GRADE METERS Industrial Grade Meters INDUSTRIAL GRADE METERS The unique modular approach of the Industrial Grade Meter line allows you to design a meter to match your specific application. Turbine choice depends on

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008 Product Data Sheet PDS 71-400/rev.I December 2008 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Features Test certificate supplied with all sensors Universal Mount Custom cell constant programmed into the

More information

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES FLS F6.60 MAGMETER FLOW SENSOR The new F6.60 and F6.63 are flow meters without moving mechanical parts which can be applied for the measurement of dirty liquids so long as they are conductive and homogeneous.

More information

Signet 4150 Turbidimeter

Signet 4150 Turbidimeter C L I S T E D 113783 US 4150 Turbidimeter Features Description The 4150 Turbidimeter system provides accurate and reliable compliant water quality monitoring for municipal and industrial applications.

More information

Signet V(D) to V(D) PVDF Conductivity Electrodes

Signet V(D) to V(D) PVDF Conductivity Electrodes Signet 2839-1V(D) to 2842-1V(D) PVDF Conductivity Electrodes Features ± 2% accuracy - Custom calibration certificate provided Dual-threaded Compact electrode length for easy in-line installation in small

More information

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS COMMERCIAL GRADE METERS Look for the silver label! Look for the silver label! COMMERCIAL GRADE METERS Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006 Product Data Sheet PDS 71-400/rev.G February 2006 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Pre-determined cell constant ensures out-of-the

More information

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics THORNTON Leading Pure Water Analytics Sanitary Sensors Sanitary Sensors Temperature Sensors 3A Sanitary Turbine Flow Sensors Pressure Sensors Tank Level Sensors High Quality, Precision Sanitary Sensors

More information

SIGNET Vortex Flow Sensors ENGLISH

SIGNET Vortex Flow Sensors ENGLISH DN X DN X DN X DN X DN X DN X DN X SIGNET Vortex Flow Sensors ENGLISH 37000.090 C12/00 English 1. Mounting Location... 1 2. Installation... 1 3. Wiring Preparation... 2 4. Wiring Options Frequency Output

More information

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue Flow Meters & Instruments Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments Technical Catalogue PDF Published October 19, 2017 flow sensors Type F3.01 Direct Mount Flow Sensors

More information

A1 Commercial Grade Meters

A1 Commercial Grade Meters A1 Commercial Grade Meters Commercial Grade Meters are designed as self-contained, battery powered units. These indicating meters come in Aluminum or Nylon only. A1 Meters are not field serviceable like

More information

Signet 7000/7001 Vortex Flow Sensors * *

Signet 7000/7001 Vortex Flow Sensors * * DN X DN X DN X DN X DN X DN X DN X Signet 7000/7001 Vortex Flow Sensors *3-7000.090* 3-7000.090 Rev. F 10/05 English English 1. Mounting Location... 1 2. Installation... 1 3. Wiring Preparation... 2 4.

More information

Signet 3719 ph/orp Wet-Tap

Signet 3719 ph/orp Wet-Tap Signet 3719 ph/orp Wet-Tap *3-3719.090* 3-3719.090 Rev H 09/07 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not

More information

SeaMetrics Flow Meters and Flow Computers

SeaMetrics Flow Meters and Flow Computers Distributed Products Fact Sheet and Flow Computers WTP-PVC body turbine flow meter WT-S Stainless steel body turbine flow meter TX115/215 Hottap insertion turbine flow meter FT420 Looppowered flow computer

More information

Actuated Valves PRICING

Actuated Valves PRICING Electric & Pneumatic Actuated Valves Actuated Valves PRICING Page Suitable for Oil-Free air handling to 5 psi, not for distribution of compressed air or gas Spears Manufacturing Company Due to Material

More information

Turbidity and Suspended Solids Transmitter

Turbidity and Suspended Solids Transmitter Data Sheet 5.1 We reserve the right to continuously improve our products and make any change in the stated specifications and dimensions without prior notice. DK: NO: SE: NL: USA: AUS: +45 45 56 06 56

More information

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013 Product Data Sheet PDS 71-400/rev.K February 2013 Model 400 and 400VP Series ENDURANCE General Purpose Conductivity Sensors INITIAL CALIBRATION NOT REQUIRED. Factory-measured cell constant ensures out-of-the-box

More information

SIGNET 2750 ph/orp Sensor ENGLISH

SIGNET 2750 ph/orp Sensor ENGLISH ENGLISH 3-2750.090 B-8/01 English SAFETY INSTRUCTIONS FOR IN-LINE ELECTRODE INSTALLATION 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifications. 3. Wear safety

More information

Flow Measurement Technology Training

Flow Measurement Technology Training Flow Measurement Technology Training Küppers Elektromechanik GmbH TASI Flow Division Küppers Elektromechanik GmbH TASI s Flow Group Territories Küppers Elektromechanik GmbH AW-Lake History AW Company formed

More information

- System Specification -

- System Specification - GF Piping Systems - System Specification - for ABS Metric Piping Systems 1. Scope This specification covers requirements for the Georg Fischer ABS Piping System intended for a wide range of applications

More information

MAIN FUNCTION FEATURES. . D = v t /2

MAIN FUNCTION FEATURES. . D = v t /2 INTRODUCTION The ultrasonic level Indicator is a low-cost, noncontact and easy-to-install measurement device. It is able to meet the every-day needs of commercial production, as well serving a more specialized

More information

Model Q45H/ Residual Chlorine Monitor...

Model Q45H/ Residual Chlorine Monitor... Model Q45H/62-63 Residual Chlorine Monitor... ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking

More information

F-1500 SERIES INSERTION TURBINE FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F

More information

ISTEC MAGNETIC METERS

ISTEC MAGNETIC METERS ISTEC MAGNETIC METERS MEASURE ANY CONDUCTIVE LIQUIDS OR SLURRIES (EVEN ABRASIVE OR CORROSIVE) WITH THE NEW MICROPROCESSOR-BASED MAGNETIC METER -- A QUALITY PRODUCT - SIMPLE - RELIABLE - AT AN AFFORDABLE

More information

2.1 Material Specification for Chlorinated Polyvinylchloride (PVC-C)

2.1 Material Specification for Chlorinated Polyvinylchloride (PVC-C) for PVC-C Metric Piping Systems 1. Scope This specification covers requirements for the Georg Fischer PVC-C Piping System intended for a wide range of applications including water, wastewater and effluent

More information

INSERTION flow sensor for continuous flow measurement

INSERTION flow sensor for continuous flow measurement INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)

More information

* * Rev M 10/14 Operating Instructions

* * Rev M 10/14 Operating Instructions English Signet 55 Blind Magmeter *-55.090* -55.090 Rev M 0/ Operating Instructions Description The Signet 55 Magmeter is an insertion-style magnetic flow sensor. The patented sensor design is available

More information

Dissolved Oxygen Measurement System with Air Blast Cleaner

Dissolved Oxygen Measurement System with Air Blast Cleaner Product Data Sheet PDS 71-DO-03/04/rev.D August 2004 MODEL DO -03/-04 Dissolved Oxygen Measurement System with Air Blast Cleaner COMPLETE SYSTEM INCLUDES sensor, analyzer, sensor washer head, mounting

More information

ProMinent S i g m a / 3 Motor Diaphragm Metering Pumps

ProMinent S i g m a / 3 Motor Diaphragm Metering Pumps pk_2_071 pk_2_104 Overview: Sigma/ 3 Sigma/ 3 Basic Type (S3Ba) Sigma/ 3 Control Type (S3Ca) Ideal for applications requiring automation, large turndown and/or feed verification (see page 133 for spare

More information

Index Flow Sensors FLOWX3 F3.00 Paddlewheel Flow Sensor page 2 FLOWX3 F111 Hot Tap Flow Sensor page 18 FLOWX3 F3.60M Insertion Magmeter page 24 FLOWX3

Index Flow Sensors FLOWX3 F3.00 Paddlewheel Flow Sensor page 2 FLOWX3 F111 Hot Tap Flow Sensor page 18 FLOWX3 F3.60M Insertion Magmeter page 24 FLOWX3 09-10 LEFLSFX10 Index Flow Sensors FLOWX3 F3.00 Paddlewheel Flow Sensor page 2 FLOWX3 F111 Hot Tap Flow Sensor page 18 FLOWX3 F3.60M Insertion Magmeter page 24 FLOWX3 F9.60M Insertion Magmeter with display

More information

Aqua Metrix. Water Analytics AquaMetrix Price List. AquaMetrix products are manufactured by. Water Analytics

Aqua Metrix. Water Analytics AquaMetrix Price List. AquaMetrix products are manufactured by. Water Analytics 2018 AquaMetrix Price List (Rev 2.0/ effective August 2018) AquaMetrix products are manufactured 100 School Street Andover, MA 01810 tel 978-749-9949 toll free 855-747-7623 (855-pHProbe) fax 978-749-9961

More information

General Purpose Toroidal Conductivity Sensors

General Purpose Toroidal Conductivity Sensors Product Data Sheet PDS 71-226/228/revF January 2011 Model 226 and 228 General Purpose Toroidal Conductivity Sensors NON-CONTACTING (TOROIDAL) SENSORS resist corrosion and fouling. SENSORS ARE IDEAL for

More information

Accessories Guide ph/orp/conductivity Sensors

Accessories Guide ph/orp/conductivity Sensors Jet Cleaners and Scrubber Accessories Isolation Ball Valves Assemblies Compression Fittings and Sheath Sets High Pressure (2500 PSIG) Sensor Housings In-line Flow Cells Nut Lock Union Style Adapters Sensor

More information

Operating Manual Model- P282 Digiflow Controller

Operating Manual Model- P282 Digiflow Controller Operating Manual Model- P282 Digiflow Controller Totalizer mode Controller 00.00 LPH 0000000.0 L t s SET SCL ENT Model- P282 Tecnical specification of flow sensor P812 Flow Rate Range : 0.5 to 5 m/s (1.6

More information

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727) F-1500 SERIES INSERTION TURBINE FLOW METER Insertion turbine flow meters are ideal for use in larger steam lines where downsizing the line size to improve flow measurement is not desirable. In these applications,

More information

Inductive conductivity meter

Inductive conductivity meter Inductive conductivity meter Type 8228 can be combined with... Configurable outputs: up to 2 transistor and up to 2 analog 4... 20 ma outputs Removable backlighted display Simulation of process values

More information

ProMinent delta Solenoid Diaphragm Metering Pumps

ProMinent delta Solenoid Diaphragm Metering Pumps Overview: delta Ideal for applications requiring metering pump accuracy with minimal pulsation (see page 127 for spare parts and page 134 for control cables) Continuous or pulsating dosing Configurable

More information

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop.

Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop. www.isomag.eu Isoil Industria a worldwide supplier of electromagnetic flowmeters Total flow control. Accurate to the drop. 1 THE IDEAL FLOWMETERS FOR ANY APPLICATION from DN03 to DN2400 wide range of process

More information

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps GRUNDFOS PRODUCT GUIDE Dosing pumps Contents Features and benefits 3 Performance range 4 Pump selection options 36 Pumped liquids List of pumped liquids 39 Identification Type key 7 Functions Functional

More information

- System Specification - for PVC-C Metric Piping Systems

- System Specification - for PVC-C Metric Piping Systems GF Piping Systems - System Specification - for PVC-C Metric Piping Systems 1. Scope This specification covers requirements for the Georg Fischer PVC-C Piping System intended for a wide range of applications

More information

* * Signet 2450 Pressure Sensor. Product Manual. English. Description. Dimensions Rev /18

* * Signet 2450 Pressure Sensor. Product Manual. English. Description. Dimensions Rev /18 English Signet 2450 Pressure Sensor *32450.0901* 32450.0901 Rev. 13 03/18 Product Manual Description The 2450 Pressure Sensor has a onepiece injection molded PVDF body and ceramic diaphragm for superior

More information

FLOWX3 F3.60M.S Insertion Magmeter

FLOWX3 F3.60M.S Insertion Magmeter FLOWX3 F3.60M.S Insertion Magmeter The FLOWX3 F3.60M.S Insertion Magmeters are suitable to measure flowrate in both metal and thermoplastic pipelines. No moving mechanical parts and the high quality materials

More information

Product Data Sheet. Flow Sensors. Insert Style Flow Sensors SDI Series DESCRIPTION HOT TAP SENSORS (OPTIONAL) APPLICATIONS FUNCTIONALITY

Product Data Sheet. Flow Sensors. Insert Style Flow Sensors SDI Series DESCRIPTION HOT TAP SENSORS (OPTIONAL) APPLICATIONS FUNCTIONALITY DESCRIPTION Flow Sensors Insert Style Flow Sensors SDI Series The Data Industrial SDI Series insert flow sensors from Badger Meter offer accurate liquid flow measurement in closed pipe systems in an easy

More information

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding

More information

Inductive conductivity meter

Inductive conductivity meter Inductive conductivity meter CIP version Type 8228 can be combined with... Standard version Perfect for concentrated liquids and wide conductivity range Pre-parameterized versions available for direct

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:

More information

SIGNET 7002 Vortex Flow Sensor ENGLISH

SIGNET 7002 Vortex Flow Sensor ENGLISH SIGNET 7002 Vortex Flow Sensor ENGLISH 3-7002.090 C-7/02 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Never install sensor without O-Rings. 3. Confirm chemical compatibility

More information

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

TEK-F LUX 1400A. Electromagnetic Flowmeter.  Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW Technology Solutions TEK-F LUX 1400A Electromagnetic Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Electromagnetic flowmeters are also

More information

Hand held ultrasonic flow meter

Hand held ultrasonic flow meter Hand held ultrasonic flow meter TDS-100H hand held ultrasonic flow meter is a battery power ultrasonic flow meter,the capability of a full size flow meter. it is carefully designed for portability and

More information

Cooling Tower Control & Dosing Bleed, Inhibitor, Timed Biocide, ORP

Cooling Tower Control & Dosing Bleed, Inhibitor, Timed Biocide, ORP DIGI-AB2RX2A-P DIGI-AB2RX2A-P-CABG DIGI-AB2RX2A-P-X/3S DIGI-AB2RX2A-P-X/3S-CABG DIGI-A2RX2A-P DIGI-A2RX2A-P-CABG DIGICHEM -ORP-XP2 Controller with Inhibitor, Non-oxidising Biocide & Chlorine Peristaltic

More information

Low Profile Insertion Vortex

Low Profile Insertion Vortex Low Profile Insertion Vortex Product Features The same insertion meter can measure Steam, Gases or Liquids. Standardize on an insertion bar that can measure line sizes 2 24 Heavy Duty & Maintenance Free

More information

SOLENOID DRIVEN DOSING PUMPS MX series

SOLENOID DRIVEN DOSING PUMPS MX series SOLENOID DRIVEN DOSING PUMPS MX series www.fwtsystems.it INTRODUCING MX SERIES FWT is pleased to introduce MX solenoid driven dosing pumps, a new series which will enable to widen the product range covering

More information

SOLENOID DRIVEN DOSING PUMPS

SOLENOID DRIVEN DOSING PUMPS MAIN COMMON FEATURES SOLENOID DRIVEN DOSING PUMPS LIQUID ENDS Power supply: 230 Vac (±10 / 15%) / 1 phase / 50/60 Hz WETTED PARTS STANDARD conf. Available conf. Reproducibility under standard conditions:

More information

Signet 2517 Brass Paddlewheel Flow Sensor * *

Signet 2517 Brass Paddlewheel Flow Sensor * * Signet 2517 Brass Paddlewheel Flow Sensor -250.090 English -2517.090 Rev. F 11/06 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifi

More information

Control and automatic dosing

Control and automatic dosing Control and automatic dosing For public and residential pools Control Basic Plus Control Basic Next Optima and Optima Next dosing pumps Panels for the galvanic and amperometric control Dosing through automatic

More information

Type Electrically Actuated Ball Valve

Type Electrically Actuated Ball Valve Electrically Actuated Ball Valve Type 179-184 General Size: ⅜ 4 Material: PVC, CPVC, PROGEF Standard PP, ABS, SYGEF Standard PVDF Seat: PTFE Seals: EPDM, FPM End Connection: Solvent cement socket, threaded,

More information

Product Specifications

Product Specifications PVC-C Metric Piping System Specifications 1. Scope This specification covers requirements for the +GF+ Georg Fischer (later named only +GF+) PVC-C Piping System intended for a wide range of applications

More information

Type Electrically Actuated Ball Valve

Type Electrically Actuated Ball Valve GF Piping Systems Electrically Actuated Ball Valve Type 179-184 General Size: ⅜ 4 Material: PVC, CPVC, PROGEF Standard PP, ABS, SYGEF Standard PVDF Seat: PTFE Seals: EPDM, FPM End Connection: Solvent cement

More information

- System Specification - for PVC-U Metric Piping Systems

- System Specification - for PVC-U Metric Piping Systems GF Piping Systems - System Specification - for PVC-U Metric Piping Systems 1. Scope This specification covers requirements for the Georg Fischer PVC-U Piping System intended for a wide range of applications

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Siemens AG 009 Supplementary electronics for 4-wire connection Design Dimensions (W x H x D) in mm (inch) Electrical connection 80 x 10 x 60 (3.15 x 4.7 x.36) Screw terminals (Pg 13.5 cable inlet)

More information

Dissolved Oxygen, ph, and Conductivity

Dissolved Oxygen, ph, and Conductivity Product Data Sheet PDS 71-steam/rev.E February 2005 Steam Sterilizable Solutions Dissolved Oxygen, ph, and Conductivity STEAM STERILIZABLE AND AUTOCLAVABLE DISSOLVED OXY- GEN, ph, AND CONDUCTIVITY SENSORS:

More information

RALF At a glance. Bioengineering RALF essentials. General

RALF At a glance. Bioengineering RALF essentials. General 0845-12b RALF 6 1/16 RALF At a glance Bioengineering RALF essentials General Autoclavable small benchtop glass reactor Versatile reactor system for numerous different applications Single as well as multiple

More information