Digital ph transmitter

Size: px
Start display at page:

Download "Digital ph transmitter"

Transcription

1 Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings Multi language, menu-guided operation Type 8205 can be combined with... Type S020 Type 6642 Type 2731 Type 2030 Type 8644 PLC INSERTION fitting Solenoid valve Diaphragm valve for continuous control On/Off Diaphragm valve Valve islands The ph transmitter is available in different models: Compact ph transmitter with integrated ph electrode Remote ph transmitter, for panel or wall mounting, to connect to the Bürkert Type 8200 ph sensor (max. 10m). The ph transmitter or sensor can be installed into pipes by using INSERTION Type S020 fittings or other suitable installation materials. It can also be installed in tanks or containers by using an industrial immersion fitting. Technical data (common to the various versions) General data Display Electrical connections Environment Relative humidity Standards and approvals Standard EMC Security Vibration Shock 15 x 60 mm, 8-digit LCD, alphanumeric, 15 segments, 9 mm high shielded cable with 1.5 mm 2 max. cross-section 80 %, non condensated EN , EN EN EN EN p. 1/12

2 System versions The compact version combines a ph sensor and an electronic module with a display in an IP65 enclosure. The access to the output terminals are provided via two cable glands or a cable plug EN The panel-mounted version consists of an electronic module 8205 integrated in a front-cover. The associated separate ph sensor is Type The output signals are provided on a terminal strip. The wall-mounted version consists of an electronic module 8205 in an IP65 enclosure. The associated separate ph sensor is Type The output signals are provided on a terminal strip via cable gland. Bürkert designed fitting ensures simple direct installation of the Bürkert transmitter into pipes from DN 15 to DN 200. Operation and display Customized adjustments, such as measuring range, engineering units can be carried out menu-supported on site via a multi-lingual display. The operation is classified according to three levels. Main Menu - ph - temperature - output current - electrode voltage - HOLD function - ph electrode calibration Calibration Menu - language - temperature unit - measuring range 4-20 ma - relay parameter definition - selection of temperature compensation (Pt1000 or manual) - display or not of electrode voltage in main menu - filter selection Direction upwards in menu Choice of digit values Steps from 0 to 9 Accept of chosen parameter or adjusted value Test Menu - Offset - Span - temperature adjustment - simulation of ph Direction downwards in menu or sideways for digit selection Relay 2 LED (contact closed) Relay 1 LED (contact closed) p. 2/12

3 Compact ph transmitter Type 8205 The sensor component consists of a replaceable combination ph-electrode, screwed into the sensor housing. The measured signal is conveyed to the transmitter via a coax plug. The Pt1000 for automatic temperature compensation is a standard feature in the sensor housing. The transmitter component converts the measured signal, displays the actual value and computes the output signals. Pressure / temperature chart Pressure (bar) 7 PVDF Metal PVC + PP PVC Temperature ( C) Principle of operation PVDF PP The most important part of the ph transmitter is the ph electrode with its ph selective glass membrane. When the electrode is immersed into the solution, an electrical charge caused by ions (H+) generates a cell voltage between the glass membrane and the solution. This electrical voltage is measured with reference to a reference electrode, located around the ph glass electrode. The cell voltage of the combination electrode is directly proportional to the ph value. The transmitter functions in a two wire circuit (without relay) or three wire circuit (with relays - limits values freely adjustable) and requires a power supply of V DC. A ma standard signal proportional to the ph or to the temperature ( C) is available as output signal. General data Compatibility Materials Housing, cover, lid, nut Front panel foil / Screws Cable plug, glands Wetted parts materials Fitting Sensor holder / Pt1000 Seal Electrode with fittings S020 (see corresp. datasheet) PC Polyester / Stainless steel PA Brass, stainless steel /316L, PVC, PP or PVDF PVDF / Stainless steel (316Ti) FKM (EPDM included in delivery) UNITRODE ph Electrical connections Cable plug EN or cable glands M20 x 1.5 Complete device data (Fitting + Electronics) Pipe diameter DN 15 to 200 ph measurement Measuring range Resolution Accuracy Minimal range Temperature measurement Measuring range Resolution Accuracy Temperature compensation ph 0.01 ph ±0.02 ph, after proper electrode calibration 0.5 ph unit (i.e 6.7 to 7.2 corresponding to 4-20 ma) -30 to +140 C 0.1 C ± 1 C automatic (integrated Pt1000) or manual (user programmed) - reference temperature 25 C Medium temperature max. with fitting in PVC: 50 C - PP: 80 C - PVDF: 100 C - stainless steel, brass: 130 C Fluid pressure max PN6 (see pressure / temperature chart) Electrical data Power supply Current consumption with sensor Output Relays (option) Environment Ambient temperature Operation Storage Standard Protection class V DC, filtered and regulated 80 ma - transmitter with relays 20 ma - transmitter without relay 4-20 ma programmable, proportional to ph or T C max. loop impedance: 1000 Ω at 30 V DC; 750 Ω at 24 V DC; 250 Ω at 15 V DC 2 relays, freely programmable, 3A, 230 V AC 0 to +60 C 4 to 30 C (limited through the electrode) IP65 with cable gland mounted and tightened or with obturator locked if not used. Specific technical data: Electrode UNITRODE ph Fluid - Clean (drinking water, aquarium, swimming pool...) - Contamined (effluent rinse water, cooling water, electroplating, paints, cosmetics...) - with low conductivity (pure and rainwater...) - containing sulfides/proteins (tannery, animal breeding, effluent, foodstuffs, cosmetics, biotechnology...) Measuring range ph Min. conductivity 2 μs/cm (200 kω.cm) Housing glass shaft Medium pressure 0-6 bar Medium temperature C Max. pressure at max. temperature 4 bar Diaphragm Two clogging free Single pores Reference electrolyte polymer p. 3/12

4 Installation The 8205 ph transmitter can easily be installed into any Bürkert INSERTION fitting system (S020) by just fixing the main nut. Mount the compact ph transmitter in vertical position (max. ±75 ) into a horizontal pipe. The electrode must continuously be immersed into the measuring fluid in order to protect it from drying out The transmitter must be protected from constant heat radiation and other environmental influences, such as direct exposure to sunlight. An industrial immersion kit allows installation of this transmitter into tanks or containers. The following lengths are available: 500, 1000, 1500, 2000 mm. Special lengths on request. Dimensions [mm] 180 Compact version Immersion kit Ø 145 Ø 91 L L [mm] (190) H DN H [mm] [mm] T-Fitting Plastic St. St. spigot spigot L Ø 75 Ø 104 Ø 145 * using fusion spigot ( , or in PP, PVDF or PE) for orifice DN p. 4/12

5 Remote ph transmitter Type 8205 (for connection to Bürkert sensor Type 8200) The remote ph transmitter Type 8205 is available in 2 versions: - Panel-mounted ph transmitter General data Compatibility Bürkert ph sensor Type 8200 Materials Housing, cover Front panel foil Screws Cable plug, glands Electrical connections PC (panel-mounted version); ABS (wall-mounted version) Polyester Stainless steel PA Terminals (panel-mounted version) or terminals via 5 cable glands M16 x 1.5 (wall-mounted version) - Wall-mounted ph transmitter A separate compact ph sensor 8200 from Bürkert must be associated with this remote ph transmitter. This sensor Type 8200 must be ordered separately. Technical specifications 115/230 VAC Voltage supply 27 V DC regulated, max. current: 250 ma integrated protection: fuse 250 ma temporised power: 6 VA Electrical data Power supply Panel-mounted version Wall-mounted version Current consumption with sensor Sensor input Cable length Output Relays (option) Environment Ambient temperature Operation and storage Standard Protection class V DC, filtered and regulated V DC, filtered and regulated or 115/230 V AC - 50/60 Hz (see technical specifications 115/230 VAC) 80 ma - transmitter with relays 20 ma - transmitter without relay Analog signal from ph electrode and Pt1000 max. 10 m (distance between sensor and transmitter) 4-20 ma programmable, proportional to ph or T C max. loop impedance: 1000 Ω at 30 V DC; 750 Ω at 24 V DC; 250 Ω at 15 V DC 2 relays, freely programmable, 3A, 230 V AC 0 to +60 C IP65 (panel-mounted and wall-mounted version) IP20 (panel-mounted version, inside the cabinet) Dimensions [mm] Panel-mounted version Wall-mounted version p. 5/12

6 Remote ph sensor Type 8200 (for connection to Bürkert transmitter Type 8205) A wide range of ph holders enable ph measurement in various applications. General data Compatibility Materials Fitting Sensor holder G2 connection G1 connection Sanitary Triclamp Pt1000 Seal with all fittings S020 (see corresp. datasheet) Brass, Stainless steel /316L, PVC, PP or PVDF Stainless steel, PVC, PP, PVDF PVC Stainlesss steel (316Ti / ), DN40, 50 Stainless steel (316L / DIN ) Stainless steel (316 Ti) FKM (EPDM option) Electrode Type UNITRODE ph 120 Type LOGOTRODE ph 120 Type MECOTRODE Electrical connections Coaxial shielded cables with connector for ph and 4-wire cable for Pt1000 A complete ph sensor system consists of (see installation example of Type 8200): A. complete armature with seals installed on: 1. Bürkert Fitting (G2 connection) 2. G1 connection 3. Tri-Clamp connection 4. Sanitary connection (according to DIN11851) B. ph-electrode C. Pt1000 (option) D. ph+pt1000 shielded cable (2, 5 or 10 m) Complete device data (fitting + sensor) Pipe diameter DN 15 to 200 Measuring range ph (depends on electrode) Medium temperature max. Temperature compensation with UNITRODE ph 120 or MECOTRODE and fitting in PVC: 50 C - PP: 80 C - PVDF: 100 C - stainless steel, brass: 130 C with LOGOTRODE ph 120: 50 C automatic (integrated Pt1000) or manual compensation reference temperature 25 C Tri-Clamp is a registered Trademark of Alfa Laval Inc. Electrical data Output Analog signal, to be connected to remote electronic module Type 8205 Specific technical data Electrode LOGOTRODE ph 120 UNITRODE ph 120 MECOTRODE Fluids - Clean like drinking water, aquarium, swimming-pool - Contamined like effluent rinse water, cooling water, electroplating, paints, cosmetics - containing sulfides/proteins like tannery, animal breeding, effluent, foodstuffs, cosmetics, biotechnology - Higher pressure applications Measuring range ph ph ph Fluid pressure 0-2 bar 0-6 bar 1) 0-16 bar 1) Temperature -10 to +60 C 0 to +130 C 0 to +130 C Ambient temperature Operation Storage 0 to +60 C 4 to +30 C 0 to +60 C 4 to +30 C 0 to +60 C 4 to +30 C Minimal conductivity 2 μs/cm 2 μs/cm 50 μs/cm Max. pressure at max. temperature 2 bar 4 bar 3 bar Number of diaphragms Diaphragm single pore single pore HP ceramics Reference electrolyte polymer polymer gel 1) only 0-3 bar if used with holder Type 8200 with Tri-Clamp or sanitary connection and with protection tube p. 6/12

7 Installation of Type 8200 Holder for Type S020 horizontal mounting Holder for connection 1 horizontal mounting C D A B A. complete armature with seals installed on: 1. Bürkert Fitting S020 (G2 connection) 2. G1 connection 3. Tri-Clamp connection 4. Sanitary connection (according to DIN11851) B. ph-electrode C. Pt1000 (option) D. ph + Pt1000 shielded cable (2, 5 or 10 m) (option) E. PVC adapter piece 1) Holder long version 2) Holder short version A 1) D A 2) E* 1 * With standard PVC connection. Not in Bürkert program C 2 B 2 C B First select and install the required fitting into a horizontal pipe, according to specific requirements of the sensor and material (temperature and pressure). After having connected the ph sensor to the Type 8205 transmitter and having calibrated the unit, cautiously install the complete ph sensor in vertical position (max. ±75 ) on the fitting. The electrode must continuously be immersed into the measuring fluid in order to protect it from drying out. The sensor must be protected from constant heat radiation and other environmental influences, such as direct exposure to sunlight. Dimensions [mm] ph holder Type 8200 for installation on Bürkert Fitting S020 (G2 connection) - PVC, PP, PVDF, Stainless steel Ø (71) Ø 76 Ø 26 p. 7/12

8 Transmitter / Dimensions [mm] ph holder Type 8200 for G 1 connection - PVC short version long version Ø 42 Ø G G1 Ø 26 Ø 26 ph holder Type 8200 for Tri-Clamp connection - Stainless steel 316L ø A ø B ø A ø B 1 1/ ø 17.2 ø 5 ø 30.1 ph holder Type 8200 for sanitary connection (according to DIN 11851) - Stainless steel 316Ti Ø C E Ø D 117 DN ø C ø D E Ø 17.2 Ø 5 Ø 30.1 p. 8/12

9 Measuring chamber for ph transmitter Type 8205 The specially designed measuring chamber enables to install all ph-transmitters or electrodes in all pipe systems, either directly in the main stream or in a by-pass line. Additionnaly it enables to keep the electrode always wet and isolate it easily from the main stream for calibration purposes. ø ø 60 B-B ø 33.6 ø B B Combining the ph transmitter Type 8205 with fittings Type S020 Available fitting DN T-fitting S020 Welding tab S020 Fusion spigot S020 DN 15 DN50 DN65 DN65 DN200 DN200 ph measurement compact DN 15 DN200 ph measurement 8205 remote version DN15 Note A DN32 DN200 Note A: Use only with plastic fitting with true union acc. to DIN 8063 p. 9/12

10 Ordering chart for compact transmitter Type 8205 A compact ph transmitter Type 8205 consists of: - an INSERTION ph transmitter an INSERTION fitting Type S020 (DN15 - DN 200) (Refer to corresponding datasheet - has to be ordered separately) Specifications Voltage supply Output Relays Sensor version Electrical connection Compact V DC 4-20 ma None UNITRODE ph EN cable glands UNITRODE ph 2 cable glands ) FKM gasket in standard; 1 Kit including a black EPDM gasket for the sensor, an obturator for an M20 x 1.5 cable gland, a 2 x 6 mm multiway seal and a mounting instruction sheet is supplied with each transmitter with cable glands or 1 Kit including a green FKM and a black EPDM gaskets is supplied with each transmitter with connection EN Ordering chart for accessories for compact ph transmitter Type 8205 Description Set with 2 cable glands M20 x neoprene flat seals for cable gland or plug + 2 screw-plugs M20 x multiway seals 2 x 6 mm Set with 2 reductions M20 x 1.5 / NPT1/2 + 2 neoprene flat seals for cable gland or plug + 2 screw-plugs M20 x Set with 1 stopper for unused cable gland M20 x multiway seal 2 x 6 mm for cable gland + 1 black EPDM gasket for the sensor + 1 mounting instruction sheet Ring PC - nut Set with 1 green FKM + 1 black EPDM gasket Electrode holder with stainless steel Pt Electrode holder with titanium Pt ph electrode C, bar - UNITRODE ph Cable plug EN with cable gland (Type 2508) Cable plug EN with NPT1/2 reduction (Type 2509) - UR and UL approval Compact ph transmitter for tank installation consists of: - an INSERTION ph transmitter - an extension cable for immersion fitting - an immersion fitting - a fixing kit - Flange DN65 with stainless steel screws Description Immersion fitting - PP m Immersion fitting - PP m Immersion fitting - PP m Immersion fitting - PP m Extension cable for immersion fitting - PP m Extension cable for immersion fitting - PP m Extension cable for immersion fitting - PP m Extension cable for immersion fitting - PP m Fixing kit - Flange DN 65 with stainless steel screws p. 10/12

11 Ordering chart for remote transmitter Type 8205 A complete remote transmitter Type 8205 consists of: - a ph-transmitter Type 8205 (wall-mounted or panel-mounted version) - a ph- holder Type a ph-electrode Type 8200 (see accessories) - a shielded connection cable (ph and Pt1000 signal) (see Accessories) - a Pt1000 temperature sensor (see Accessories) - an INSERTION fitting S020 (DN15 - DN 200) (Refer to corresponding datasheet - has to be ordered separately) ph transmitter Type 8205 panel or wall-mounted version Specifications Voltage supply Output Relays Sensor version Electrical connection Panel-mounted V DC 4-20 ma None 8200 Terminal strip Terminal strip Wall-mounted V DC 4-20 ma None 8200 cable glands cable glands V AC 4-20 ma None 8200 cable glands cable glands Ordering chart - ph holder for remote transmitter Type 8205 Specifications Sensor version Material Boring for temperature sensor Pt1000 Protection tube ph-holder 8200 for installation on Bürkert fitting S020 standard PVC Yes Yes (G2 connection) PP Yes Yes PVDF Yes Yes Stainless steel Yes Yes ph-holder 8200 for G1 connection thread short PVC Yes long PVC Yes ph-holder 8200 for Tri-Clamp 1 1/2 - (dia mm) standard Stainless steel 316L Yes ph-holder 8200 for Tri-Clamp 2 - (dia. 64 mm) standard Stainless steel 316L Yes ph-holder 8200 for sanitary connection DN40 - (DIN 11851) standard Stainless steel 316Ti Yes ph-holder 8200 for sanitary connection DN50 - (DIN 11851) standard Stainless steel 316Ti Yes Ordering chart for accessories for remote ph transmitter Type 8205, ph sensor Type 8200 Description ph electrode C, bar, ph LOGOTRODE ph 120 mm ph electrode C, bar, ph MECOTRODE ph 120 mm ph electrode C, bar, ph UNITRODE ph 120 mm Temperature probe -Stainless steel sensor Pt ph coaxial cable with standard electrode plug - 2 m (for connection between 8205 controller and 8200 sensor) ph coaxial cable with standard electrode plug - 5 m (for connection between 8205 controller and 8200 sensor) ph coaxial cable with standard electrode plug - 10 m (for connection between 8205 controller and 8200 sensor) pt wire cable with M8 connector - 2 m (for connection between 8205 controller and 8200 sensor) pt wire cable with M8 connector - 5 m (for connection between 8205 controller and 8200 sensor) pt wire cable with M8 connector - 10 m (for connection between 8205 controller and 8200 sensor) FKM gasket for all holders Type EPDM gasket for all holders Type p. 11/12

12 Ordering chart for accessories for all version of Type 8205, Type 8200 Description Storage solution for electrodes (KCl 3M), 500 ml Buffer solution, 500 ml, ph = Buffer solution, 500 ml, ph = Buffer solution, 500 ml, ph = Factory 2-point ph calibration certificate Measuring chamber stainless steel 316L (1.4404) 1) with G 1/2 connection thread ) other materials on request Note: Compact ph transmitter 8205, remote (Wall-mounted or Panel-mounted versions) ph electronic module 8205, ph holder 8200, ph electrode, Pt1000 sensor, connection cable, INSERTION fitting S020, have to be ordered separately. Interconnection possibilities with other Bürkert devices Type Diaphragm- Valve with pilot valve Type Process Valve with positioner Printer - Type Wall-mounted or panel-mounted Type Compact ph transmitter Type ph sensor Type S020 - INSERTION Fitting (see corresp. datasheet) Measuring chamber To find your nearest Bürkert facility, click on the orange box In case of special application conditions, please consult for advice. We reserve the right to make technical changes without notice. 0705/4_EU-en_ p. 12/12

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:

More information

Inductive conductivity meter

Inductive conductivity meter Inductive conductivity meter Type 8228 can be combined with... Configurable outputs: up to 2 transistor and up to 2 analog 4... 20 ma outputs Removable backlighted display Simulation of process values

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:

More information

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands Conductivity meter Configurable outputs: two transistor and single or dual analog 4... 20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

Inductive conductivity meter

Inductive conductivity meter Inductive conductivity meter CIP version Type 8228 can be combined with... Standard version Perfect for concentrated liquids and wide conductivity range Pre-parameterized versions available for direct

More information

Insertion magnetic inductive flowmeter

Insertion magnetic inductive flowmeter Insertion magnetic inductive flowmeter Sensor without moving parts Flowmeter with On/Off control Application related calibration by Teach-In function Clean in place (CIP) FDA-compliant materials Type 8041

More information

INSERTION flow sensor for continuous flow measurement

INSERTION flow sensor for continuous flow measurement INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)

More information

Positive displacement batch controller

Positive displacement batch controller 8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total

More information

INSERTION Adaptor for analysis

INSERTION Adaptor for analysis INSERTION Adaptor for analysis Type can be combined with... Universal adaptor for type 8202 and 8222 ELEMENT s in pure, aggressive or contaminated liquids Adaptation into standard piping systems or conversion

More information

Paddle-wheel flow controller with optical principle for On/Off control

Paddle-wheel flow controller with optical principle for On/Off control Paddle-wheel flow controller with optical principle for On/Off control Type 8039 can be combined with... Indication, monitoring, transmitting and On/Off control in one device. Programmable s (transistor

More information

INSERTION flowmeter with paddle wheel, ELEMENT design

INSERTION flowmeter with paddle wheel, ELEMENT design INSERTION flowmeter with paddle wheel, design Up to PN, size of measurement pipes: DN to DN400 Configurable outputs: one or two transistor output(s) and single or dual 4... ma analog output(s) Removable

More information

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65 2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, 10-65 Suitable for aggressive media High flow rate value -piece Actuator with adjustable limit switches 2-piece Visual position

More information

Probe holders for analytical probes

Probe holders for analytical probes Probe holders for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications

More information

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50 2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50 Suitable for aggressive media High flow rate value Actuator with adjustable limit switches Visual position indicator Safe

More information

Positive displacement flowmeter

Positive displacement flowmeter Positive displacement flowmeter Configurable outputs: one or two transistor output(s) and single or dual 4...20 ma current output(s) Removable backlit display of flow rate and/or 2 two totalized volumes

More information

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading. Analogue Flow Rate Indicator, DN 15...; PN 1...16 Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a large

More information

Positive displacement flowmeter for continuous flow measurement

Positive displacement flowmeter for continuous flow measurement 8070 Positive displacement flowmeter for continuous flow measurement High accuracy Medium with high viscosity Mounting and dismounting of the electronics by a quarter-turn Connection to Bürkert devices

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50 /- and 3/-way Ball Valve with pneumatic rotary actuator, plastic body, DN -50 Radially expandable body Pneumatic actuator in compact model Optical position indicator Control valve acc. to NAMUR Type 5

More information

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65 2/2-way ball valve with electric rotary actuator, ball valve in, N 10-65 Suitable for aggressive media High flow rate value -piece Actuator with adjustable limit switches 2-piece Visual position indicator

More information

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50 2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50 Suitable for aggressive media High flow rate value Actuator with adjustable limit switches Visual position indicator Safe

More information

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics 654 3/-way and x 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Fast response times Space saving ( x 3/-way version) Type 654 can be combined with...

More information

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm 2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm Lockable manual override as standard For liquid, gaseous and aggressive media Long service life, even in non-lube conditions

More information

MAGNETIC INDUCTIVE FLOW TRANSMITTER

MAGNETIC INDUCTIVE FLOW TRANSMITTER MAGNETIC INDUCTIVE FLOW TRANSMITTER INSTRUCTION MANUAL INTRODUCTION 1 INTRODUCTION 1.1 Symbols used... 3 1.2 General Safety Instructions... 3 2 QUICKSTART 2.1 Installation... 4 2.2 Programming... 5 2.3

More information

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Data Sheet 22943 Page 1/9 JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Brief description The sensor detects the electrolytic conductivity of a process liquid.

More information

INSERTION Adapter/Fitting for analytical devices

INSERTION Adapter/Fitting for analytical devices INSERTION / for analytical devices Universal adapter/fitting for Type 8202 and 8222 measuring devices in pure, aggressive or polluted liquids Adaptation into standard piping systems or conversion of Bürkert

More information

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Data Sheet 22943 Page 1/9 JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Brief description The sensor detects the electrolytic conductivity of a process liquid.

More information

Electrical position feedback for actuator sizes Ø mm

Electrical position feedback for actuator sizes Ø mm Electrical position feedback for actuator sizes Ø 40-125 mm Type 1062 can be combined with Simple installation, convertible or retrofittable Self-adjusting trip cam for closed position LEDs provide local

More information

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50 2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, 10-50 (2652) (2655) 2 or ball valve Pneumatic actuator Compact design Visual position indicator Types 2652/2655 can be

More information

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m 3 /h, kg/h, l/min,

More information

Conductivity Measuring Cells ConduMax W CLS 19

Conductivity Measuring Cells ConduMax W CLS 19 Technical Information TI 110C/24/ae Conductivity Measuring Cells ConduMax W CLS 19 Two-electrode measuring sensors with cell constant k = 0.01/cm or k = 0.1/cm Area of application Measurement in pure and

More information

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

2/2-way Angle Seat Valve, manually operated, for media up to +180 C 2/2-way Angle Seat Valve, manually operated, for media up to +180 C Position indication Adjustable flow rates Stainless steel 316L valve body Compact industrial design with long service life /2702 can

More information

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control INLINE Quarter-Turn ON/OFF Control System for Monitoring and Switching Mechanical adjustment of set point No contact to Fluid thanks to INLINE

More information

Temperature Sensor without thread

Temperature Sensor without thread 1 Product Information TFP-49, -169, -189, -06 Temperature Sensor without thread Application / Specified Usage Authorizations Installation in thin-walled pipes and vessels No product contacting of the sensor

More information

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm / or 3/-way Solenoid Valve, with pivoted armature and isolating diaphragm Type 0330 can be combined with Lockable manual override as standard For liquid, gaseous and aggressive media Long service life,

More information

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Technical Information Cleanfit CPA471 Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines Application Chemical industry Wastewater treatment Plant design Tanks and

More information

Plastic tube variable area flowmeter for liquids and gases

Plastic tube variable area flowmeter for liquids and gases Plastic tube variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding connections)

More information

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions Technical Information Cleanfit H CPA475 Retractable assembly for ph, ORP measurement under sterile conditions Application Food industry Beverage industry Pharmaceutical industry Drinking water The retractable

More information

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2 2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2 Type 6281 can be combined with... User friendly - one solenoid for all orifices Waterhammer free and low noise NC or NO Manual override optional

More information

2/2-way Solenoid Valve with servo diaphragm

2/2-way Solenoid Valve with servo diaphragm 2/2-way Solenoid Valve with servo diaphragm Type 5282 can be combined with... Pivoted armature pilot drive with manual override Magnetic drive completely isolated from fluid by diaphragm Circuit function

More information

INLINE fitting with paddle-wheel for flow measurement

INLINE fitting with paddle-wheel for flow measurement ININE fitting with paddlewheel for flow measurement Type can be combined with... N 06 to N 65 Closed pipe system, i.e. sensor inside fitting Quarterturn technology Electronics available for Indication,

More information

Inline Paddle Wheel Flow Switch

Inline Paddle Wheel Flow Switch Inline addle Wheel Flow Switch Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type can be combined with... Valve Alarm

More information

2/2 or 3/2 way direct acting rocker solenoid valve

2/2 or 3/2 way direct acting rocker solenoid valve 2/2 or 3/2 way direct acting rocker solenoid valve With isolating diaphragm Ultra low dead volume Type 6126 can be combined with... High back-pressure tightness Normally closed, normally open or universal

More information

INSERTION fitting for flow measurement or analysis

INSERTION fitting for flow measurement or analysis INSERTION fitting for flow measurement or analysis Type S020 can be combined with... Universal fitting for INSERTION sensors, transmitters, batch controllers in pure, aggressive or contamined liquids arge

More information

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Solenoid Valve, direct-acting, NC or NO 3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined

More information

Pneumatic control unit for decentralized automation of ELEMENT process valves

Pneumatic control unit for decentralized automation of ELEMENT process valves 890 Pneumatic control unit for decentralized automation of ELEMENT process valves Type 890 can be combined with... Compact design Integrated pilot valve with manual override Integrated control air routing

More information

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity Data Sheet 20.27 Page / ecotrans Lf 0/02 Microprocessor Transmitter / Switching Device for Conductivity Type 2027 Housing for DIN rail mounting (5 x 7.5 mm to EN 0 75 A.) Brief description The JUMO ecotrans

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

Signet 2551 Magmeter Flow Sensor

Signet 2551 Magmeter Flow Sensor Signet 2551 Magmeter Flow Sensor Available in a variety of wetted materials and ideal for pipe sizes up to DN900 (36 in.) Features Test certificate included for -X0, -X1 Patented Magmeter technology No

More information

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base 3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base Sub-base Direct-acting, normally closed and normally open Brass and stainless steel body Electrical cable plug Form A With or without manual override

More information

Continuous level sensor NSK

Continuous level sensor NSK SENSORS FOR FOOD AND BIOPHARMA. Product Information NSK-157, -357, -358 FOOD Continuous level sensor NSK Application Continuous level monitoring in metallic vessels up to 3 m in height Ideal for highly

More information

Type Pressure Transmitter with display. Pressure Transmitter. Technical data. DN15-50 Body material. Stainless steel 316L Actuator material

Type Pressure Transmitter with display. Pressure Transmitter. Technical data. DN15-50 Body material. Stainless steel 316L Actuator material 2/2-way Angle Seat Valve, manually operated, for media up to +180 C Position indication Adjustable flow rates Stainless steel 316L valve body Compact industrial design with long service life Excellent

More information

Analysis ph / ORP. Characteristics System. Applications Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

Analysis ph / ORP. Characteristics System. Applications Food industry Chemical and Pharmaceutical industry Water and Sewage treatment GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 System Process connection Pressure range Media temperature Transmitter, digital

More information

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518 3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions

More information

Fluid Control System with Diaphragm Valve For Polluted, Dirty, Aggressive and Ultra-Pure Fluids

Fluid Control System with Diaphragm Valve For Polluted, Dirty, Aggressive and Ultra-Pure Fluids TOP Control System / ON/OFF and Proportional /-Way, / Advantages/Benefits Decentralized Intelligence for ON/OFF and Proportional control of processes Customized System Solutions for Easy LINK and Easy

More information

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO. Process Pressure Transmitter with HART -communication Ceramic Sensor accuracy according to IEC 60770: 0.1 % FSO Nominal pressure from 0... 160 mbar up to 0... 20 bar Output signals 2-wire:... 20 ma others

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice INDUCTIVE CONDUCTIVITY SENSOR Instruction Manual Bürkert 00 Subject to technical change without notice INTRODUCTION Table of Contents. INTRODUCTION.... Symbols used.... General safety instructions....

More information

Analysis ph / ORP. Applications. Characteristics. Food industry Chemical and Pharmaceutical industry Water and Sewage treatment

Analysis ph / ORP. Applications. Characteristics. Food industry Chemical and Pharmaceutical industry Water and Sewage treatment GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax - 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Product Information Analysis ph / ORP System Process connection

More information

Direct-acting 3/2 way plunger valve

Direct-acting 3/2 way plunger valve Direct-acting 3/2 way plunger valve Direct-acting, compact valve with diameter of up to DN 2.5 Vibration-proof, bolted coil system Banjo threaded connection for direct mounting on pneumatic valves Type

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

SATRON VTe pressure transmitter

SATRON VTe pressure transmitter SATRON VTe pressure transmitter belongs to the series V-transmitters which will have both analog and smart properties. SATRON VTe is used for 0-4 kpa...0-00 MPa ranges. The transmitter communicates in

More information

Pressure transmitter COMPACT ECOnomic

Pressure transmitter COMPACT ECOnomic Pressure transmitter COMPACT ECOnomic for food/pharmaceutical/biotechnology, Type series CA1110 Features Digitale pressure transmitter Hygienic design according to EHEDG Case and wetted parts of stainless

More information

JUMO ecotrans Lf 01/02

JUMO ecotrans Lf 01/02 Data Sheet 07 Page /7 JUMO ecotrans Lf 0/0 Microprocessor Transmitter/Switching Device for Conductivity Housing for DIN rail mounting (5 mm 7.5 mm to EN 075 A.) Brief description The JUMO ecotrans Lf 0/0

More information

Simple float switch TCL001/8181

Simple float switch TCL001/8181 Simple float switch Switch for neutral and aggressive liquids NO/NC, alternating Reed contact Vertical or horizontal mounting Molded lying leads (Type 8181) or cable (Type TCL001) Float switch with hermetically

More information

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam Metallic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

2/2 and 3/2-way Flipper Solenoid Valve, with hermetic isolation of fluid

2/2 and 3/2-way Flipper Solenoid Valve, with hermetic isolation of fluid 2/2 and 3/2-way Flipper Solenoid Valve, with hermetic isolation of fluid Low internal volume Low power consumption High back pressure tightness Optional impulse model Type 6124 can be combined with...

More information

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet Magnetic-inductive flow meter EPS / UMF2 Technical data sheet high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials low-cost grounding

More information

Operating Instructions (from serial number 3000)

Operating Instructions (from serial number 3000) Conductivity meter Leitfähigkeits-Messgerät Conductivimètre Operating Instructions (from serial number 3000) Bedienungsanleitung (ab Serien-Nummer 3000) Manuel d utilisation (à partir du numéro de série

More information

Flow switches Series AD/VH

Flow switches Series AD/VH Flow switches Series AD/VH Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling,

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,

More information

Signet 3719 ph/orp Wet-Tap Assembly

Signet 3719 ph/orp Wet-Tap Assembly Signet 3719 ph/p Wet-Tap Assembly Features Electrode removal without process shutdown Space saving 45 mm (1.75 in.) short-stroke design Sealed pneumatic dampening for smooth and safe operation SafeLoc

More information

Electromagnetic Flow Monitor magphant

Electromagnetic Flow Monitor magphant Technical Information TI 036D/06/en No. 50078457 Electromagnetic Flow Monitor magphant Monitoring and measurement Flow monitoring with selectable limit values (relay output) Flow measurement via 4...20

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

3/2-way Solenoid Valve for pneumatics

3/2-way Solenoid Valve for pneumatics 656 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Type 656 can be combined with... Fast response times Type 506 Type 510/511

More information

2/2- and 3/2-way solenoid valve for aggressive fluids

2/2- and 3/2-way solenoid valve for aggressive fluids 2/2- and 3/2-way solenoid valve for aggressive fluids Type 0121 can be combined with Direct-acting, media-separated valve with diameter of up to DN 8 Maintenance-free pivoted armature technology Vibration-proof,

More information

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2

2/2-way Compact Solenoid Valve, G 1/4 - G 1/2 2/2-way Compact Solenoid Valve, G 1/4 - G 1/2 Stainless steel body Type 6027 Compact can be combined with Direct-acting, normally closed Brass and stainless steel body Electrical connection cable plug

More information

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam By-pass flowmeter with orifice plate (compact system PRC and separate system PR) for big flow ranges Flow indication by

More information

EXNER PROCESS EQUIPMENT

EXNER PROCESS EQUIPMENT EXNER PROCESS EQUIPMENT EXTRACT Process retractable holder Technical information All brand and product names are trademarks of the company EXNER PROZESS EQUIPMENT Copyright notice Distributed by: EXNER

More information

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube variable area flowmeter for gases, liquids and steam Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,

More information

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter Data sheet 902815 Page 1/10 JUMO Dtrans T100 Screwin RTD Temperature Probe with/without Transmitter For temperatures between 50 and +260 C EHEDG certification RoHScompliant in EU and China Configuration

More information

SATRON VDt Differential Pressure Transmitter

SATRON VDt Differential Pressure Transmitter SATRON VDt differential pressure transmitter belongs to V-transmitter family. The series V transmitters have both analog and smart properties. SATRON VDt is used for -,1kPa...-15 MPa ranges. It is a 2-wire

More information

AirLINE and AirLINE Quick electrical/pneumatic Automation System

AirLINE and AirLINE Quick electrical/pneumatic Automation System AirLINE and AirLINE Quick electrical/pneumatic Automation System Type 8644 can be combined with Fully compatible with Rockwell Combination of Fieldbus, pilot valves and I/O modules higher fl exibility

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

ph-kompaktelektrodensystem sensopac CPA 320

ph-kompaktelektrodensystem sensopac CPA 320 Technische Information TI 0C/0/de ph-kompaktelektrodensystem sensopac CPA 0 One of the two reference systems is specially protected so that only the second monitoring reference system is affected by penetration

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance

More information

Solenoid valve. Technical data Orifice 1/4 4 Body materials Actuator material Seal material Media Viscosity. Control medium Port connections

Solenoid valve. Technical data Orifice 1/4 4 Body materials Actuator material Seal material Media Viscosity. Control medium Port connections /-way Diaphragm Valve with plastic body, pneumatically operated, 1/ 3 with true union 3 with fl ange pplications with aggressive media Flow optimised body with zero dead volume Self draining installation

More information

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level ETP80 Electronic Transmitter for Pressure, Differential Pressure and Level The ETP80 is a series of pressure transmitters with a wide range of s to suit most applications. The transmitters can measure

More information

2/2-way Angle-Seat Valve for media up to +180 C, threaded port connection, DN 13-65

2/2-way Angle-Seat Valve for media up to +180 C, threaded port connection, DN 13-65 2/2-way Angle-Seat Valve for media up to +180 C, threaded port connection, DN 13-65 Standard valve body Type 2000 can be combined with Short valve body High flow rate and long life cycle Very high cycle

More information

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4 Flow Switches Index: B / 923-1838 BFS-10-N / BFS-10-O for monitoring liquids, with or without optical display Features set point continuously adjustable rugged, low hysteresis, any mounting position, high

More information

Continuous level sensor NSK

Continuous level sensor NSK SENSORS FOR FOOD AND BIOPHARMA. Product Information NSK-187, -387, -388 FOOD Continuous level sensor NSK Application Continuous level monitoring in metallic vessels up to 2.5 m in height Ideal for highly

More information

Electromagnetic Flow Monitor magphant

Electromagnetic Flow Monitor magphant Technical Information TI 036D/24/ae Electromagnetic Flow Monitor magphant Flow monitoring in 1 to 80 pipes with conductive liquids Monitoring and measurement Flow monitoring with selectable limit values

More information

Technical Features Flow Monitor Part No. Wire Associated Sensor 4-20 ma Digital Relay Power Tech. Sensor Input Output Output Output F9.00.L 2 wire Hal

Technical Features Flow Monitor Part No. Wire Associated Sensor 4-20 ma Digital Relay Power Tech. Sensor Input Output Output Output F9.00.L 2 wire Hal FLOWX3 F9.00 Flow F9.00 FLS FLOWX3 F9.00 Flow Monitors & Transmitters are designed to convert the signal from all FLOWX3 flow sensors into a display indication and a 4-20 ma signal for long distance transmission.

More information

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65 2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65 Type 2000 can be combined with High flow rate Long life cycle NC and NO universal s with modular universal accessory

More information

Model Q45H/ Residual Chlorine Monitor...

Model Q45H/ Residual Chlorine Monitor... Model Q45H/62-63 Residual Chlorine Monitor... ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking

More information

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Suitable for all kind of liquids Viscosity up to 120000 mpa s Excellent performance with changing process conditions

More information

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids For use in large diameter pipes as an economical solution for flow measurement Flow rate measurement

More information