Instrument Enclosure Assemblies
|
|
- Clyde Barber
- 5 years ago
- Views:
Transcription
1 Instrument Enclosure Assemblies Standard instrument enclosure Instrument enclosures offer a simple solution for the customer who doesn t have the time to install Signet meters into panels. Whether it s a display transmitter or controller, these panels make installation easy. Just mount the Instrument Enclosure onto the wall using the integral mounting points, and wire the sensor inputs and outputs to the optional DIN rail terminal block. With the optional DIN rail mounted power supply (equipped with an 8-foot 120 VAC power cord), the enclosure is simply plug and play. Use the easy part-number configurator to customize the instrument enclosure to fit any process measurement needs. Select the Signet 9900 SmartPro with desired options, then complete the enclosure by deciding whether to add a DIN rail, a power supply, terminal blocks, or a display pre-wired to the terminal block. Standard enclosure choices include a solid or clear hinged door. The Signet instrument is mounted through the solid door, or behind the clear door. Both enclosure styles are equipped with stainless steel hinges and pad-lockable latches. The enclosure can be configured with multiple conduit ports at the bottom for field wiring; with the prewired configuration, a simplified wiring diagram is included. Each pre-wired instrument enclosure is factory tested before shipping. No other industrial piping systems manufacturer offers the product breadth, or combined quality and simplicity, as. Features Convenience (mount the enclosure, then simply land the field wires) Hundreds of configuration possibilities (flow, batch, ph/orp, cond/res, temp/press, level, etc.) NEMA 4X Stainless hinges and latches Pad-lockable latch Simplified field wiring diagram Optional features include:»» Pre-wired between display and DIN rail terminals»» Clear door with instrument mounted behind»» Universal input VAC to 24 VDC regulated power supply»» 8ft, 120 VAC power cord»» DIN rail terminal block for easy termination of field wires»» Pre-drilled conduit holes equipped with liquid-tight cord grips»» For any custom instrument enclosures, please contact your local sales office Customizing includes 8860s, 8900s, or 4630 chlorine flow cell block enclosures; or adding lights, alarms, or switches
2 FLO W Specifications General Materials of construction Enclosure Made of gray, hot molded fiberglass reinforced polyester UV stabilized Hinges 304 SS Lockable latches 316 SS (Standard enclosure) 304 SS (Compact Enclosure) Mounting hardware (Compact Enclosure) Brackets 304 SS Screws 304 SS Inserts Brass Clear Window (option on standard Polycarbonate enclosures) Liquid tight cordgrips All nylon construction with TPE and /or Buna N sealing gland Electrical Terminal Block DIN rail, AWG 26 16, Width: 0.17, Mounting type: NS 35/7,5, NS 35/15, NS 32 Optional power supply DIN rail 110/220vac, 50/60 Hz to 24vdc 300 ma or 600mA For Signet components, see individual data sheets at Standards and Approvals NEMA 4X System Overview Panel Mount Instrument in Enclosure Sensors sold seperately SIGNET 515/ Flow ph /ORP Cond/Res Temp/ Press/Level Signet Fittings (sold separately) See individual sensor data sheets 2
3 Dimensions Standard Enclosure X Compact Enclosure X Compact instrument enclosure 3
4 Ordering Information Choose one P, P, P, P, P, P, BC, Choose 5090 one , 5500, 5600, 5700, 5800, 5900, **8250, *8350 *8550, *8750, *8850 NOTE: For model with ** select a -2, -3. For models with * select -1, -2, or -3 Standard Standard Instrument Instrument Enclosure Enclosure - with options - with options -S Instrument mounted through solid, hinged, door -C Instrument mounted behind clear, hinged, door -1 With 24vdc Power Supply Input vac 50/60 hz -2 No power supply - 1 with DIN rail, terminal blocks, pre - wired wiring harness - 2 No DIN rail, no terminal blocks, no wiring harness - 0 No conduit holes - 1 One Conduit hole with cable connector - 2 Two Conduit holes with cable connector - 3 Three Conduit holes with cable connector - 4 Four Conduit holes with cable connector 3- */** Example P/N: P-S NOTE: 8ft, 3-prong, Power Cord only included when 24vdc Power Supply, and Conduit Holes are selected Choose one P, P, P, P, P, P, BC, 5090 Compact Compact Instrument Instrument Enclosure Enclosure - (no power - (no supply, power supply, no DIN no rail DIN rail terminal terminal block) block) - 0 No conduit holes - 1 One conduit holes with cable connectors 3- */** - S Example P/N: P-S-2, up to 3 conduit holes Tel. (714) , Toll Free (800) , Fax (714) us.ps@georgfischer.com, #M280 (5/14) 2014 Georg Fischer LLC Printed in USA
5 Standard Multi-Parameter Instrument Enclosure The Standard Multi-Parameter Instrument Enclosures offer a simple solution for the customer who doesn t have time to install Signet meters into panels. Whether it s a display transmitter or controller, these panels make installation easy. Just mount the instrument enclosure on the wall using the integral mounting points, and wire the sensor inputs and outputs to the DIN rail terminal blocks. With the optional DIN rail mounted power supply and optional power cord, the enclosure is simply plug-andplay. Use the easy part-number configurator to customize the enclosure to your application. Standard enclosure choices include four different sizes and either a solid or clear hinged door. The Signet instrument is mounted through the solid door or behind the clear door. Both enclosure styles are equipped with stainless steel hinges and padlockable latches. The enclosure can be configured with multiple conduit ports for easy field wiring; a simplified wiring diagram is included. Each pre-wired instrument enclosure is factory-tested before shipping. No other industrial piping systems manufacturer offers the product quality and efficiency as. Features Wall-mount gray fiberglass enclosure with hinged door Four enclosure sizes with two door options (solid or clear) NEMA 4 or NEMA4X rating, depending on door option Stainless steel latches and hinges Lockable latches for added security Controller pre-wired to terminal blocks DIN rail grounding and wiring terminals, AWG Terminal layout wiring diagram provided for ease of installation 2, 4, or 6 pre-drilled wire entries with liquid-tight cord grips Controller installed on a metal hinged faceplate behind a clear door (clear door option) Optional USB type data loggers Optional 8 grounded power cord Optional 4 20mA adapters available for non-gf sensors Ease of installation for hassle-free system integration For custom options such as chart recorders, lights, alarms, or switches, please contact your local GF Piping Systems sales office
6 Dimensions +V -V DC OK 24V/1.0A DC OK + +V ADJ L-6-DC-4D-4A DISPLAY TRANSMITTER (EXAMPLE) VAC 0.55A 50/60Hz N L EARTH GROUND VDC (freq input 1 black) 3. Freq Input 1 (red) 4. GND (freq input 1 shield) VDC (freq input 2 black) 6. Freq Input 2 (red) 7. S3L Input 2 (red) 8. GND (freq input 2 white/shield) VDC (freq input 2 black) 10. S3L Input 1 (red) 11. GND (freq input 2 white/shield) 12. Analog Output Analog Output Analog Output Analog Output Analog Output Analog Output Analog Output Analog Output Relay 1 Common 21. Relay 1 N.O. 22. Relay 1 N.C. 23. Relay 2 Common 24. Relay 2 N.O. 25. Relay 2 N.C. 26. Relay 3 Common 27. Relay 3 N.O. 28. Relay 3 N.C. 29. Relay 4 Common 30. Relay 4 N.O. 31. Relay 4 N.C. Ordering Information Example: Using the 8900 Configurator on page 37 of the 2013 Signet Measurement and Control Product Catalog, get the required 8900 fully assembled part number: L-4-DC-4D-4A. Then add to configured enclosure below: CP Encloser Part Number Enclosure Sizes (inch) Door Type & NEMA Rating Cord Grips with Hole Cutouts Power Cable Order Description Order Description Order Description Order Description XXXX Solid fiberglass (NEMA 4) NO VAC Fiberglass with clear polycarbonate inlay (NEMA 4X) VAC Example Needed Item CP Encloser Part Number Enclosure Sizes (inch) Door Type & NEMA Rating Cord Grips with Hole Cutouts Power Cable Custom enclosures are available, contact your area sales manager or your local GF sales office. Tel. (714) , Toll Free (800) , Fax (714) us.ps@georgfischer.com, #M280 (5/14) 2014 Georg Fischer LLC Printed in USA
SIGNET 2760 DryLoc ph/orp Preamplifier
SIGNET 2760 DryLoc ph/orp Preamplifier 3-2760.090 3-2760.090 (A-3/04) English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confirm chemical compatibility before
More informationPDA2300. Economical Plastic NEMA 4X Enclosures for 1/8 DIN Digital Panel Meters FEATURES OVERVIEW
PDA2300 Economical Plastic NEMA 4X Enclosures for 1/8 DIN Digital Panel Meters Download free 3-D CAD files of these enclosures to simplify your drawings! predig.com/documentation-cad PDA2301 Enclosure
More information* * Rev. 9 01/18 Product Manual
English Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. 9 01/18 Product Manual Description The Signet 2760 ph/orp Preamplifiers with DryLoc connectors are part of Signet's growing line
More informationSignet 2760 DryLoc ph/orp Preamplifiers & Connectors
Signet 2760 DryLoc ph/orp Preamplifiers & Connectors Features In-line integral mount and submersible installation versions Automatic temperature compensation Auto configuration for ph or ORP operation
More informationSignet 2760 DryLoc ph/orp Preamplifier
Signet 2760 DryLoc ph/orp Preamplifier *3-2760.090* 3-2760.090 Rev. H 05/11 English English SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility
More informationProduct Manual MNX10043 REV 0 MODEL DSB. Dual Sensor Modular Switch box
Product Manual MNX10043 REV 0 MODEL DSB Dual Sensor Modular Switch box Contents Section I Overview Introduction..... 2 Description 2 DSB Model Selection.. 2 Section II Installation Mounting Instructions....
More informationSignet Conductivity/Resistivity Electrodes
Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 in. - Opt. ½ in.
More informationSignet 2536 Rotor-X Paddlewheel Flow Sensors
Signet 2536 Rotor-X Paddlewheel Flow s Features Operating range 0.1 to 6 m/s (0.3 to 20 ft/s) Wide turndown ratio of 66:1 Open-collector output Highly repeatable output Simple, economical design PVC (gray
More informationSIGNET Temperature Transmitter
SIGNET 83501 Temperature *38350.0901* English 38350.0901 Rev. G 3/06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.
More informationSeries 1. Series 1 Pressure Switch. Pressure Switches Inc. Quality Pressure Solutions. Pressure Switches 1 G 10 N Key Features.
Model 1A 1C 1G 1Z 1P 1H Inc. Series 1 Series 1 Pressure Switch High, Low, Differential & Vacuum Pressure Switch options available All Anodized Aluminum Construction Multiple s Available UL & cul Approved
More informationSignet Pressure Transmitter
Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents
More informationSignet Temperature Transmitter
Signet 80 Temperature English 80.090 80.090 Rev. G /0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.
More informationRCM - Direct Reading Flowmeters
Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas) Low Pressure Drop Optional Alarms and Output Signals Accuracy: ± 3% of full scale
More informationSignet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor
Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems with PVDF Sensor Features Test certificate supplied with all sensors Universal Mount Custom cell constant programmed into the
More informationAM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles
AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles Compatible with UL 1686 C1 Pin & Sleeve Devices Safer. Easier. Better. MENNEKES Non-Metallic MSR Switched and Interlocked
More informationSIGNET 7002 Vortex Flow Sensor ENGLISH
SIGNET 7002 Vortex Flow Sensor ENGLISH 3-7002.090 C-7/02 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Never install sensor without O-Rings. 3. Confirm chemical compatibility
More informationModel Q45H/ Residual Chlorine Monitor...
Model Q45H/62-63 Residual Chlorine Monitor... ATI s Model Q45H is designed for on-line monitoring and control of chlorination systems. It is available in two versions: a free chlorine monitor for drinking
More informationType 147. Electrically Actuated Lug Butterfly Valve
GF Piping Systems Electrically Actuated Lug Butterfly Valve Type 147 General Size: 2 12 Outer Body: Glass-filled PP Material: PVC, CPVC, PROGEF Standard PP, ABS, SYGEF Standard PVDF Seals: EPDM, FPM, PTFE/FPM
More informationEZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL
With Flow-Alert TM Flow Switch Reed switch and latching models Automatically signals alarm if flow is too high or too low Models available for AC or DC power supply Latching models include Hirschmann type
More informationSignet 515 Rotor-X Paddlewheel Flow Sensors
Signet 515 Rotor-X Paddlewheel Flow Sensors Features Operating range 0.3 to 6 m/s (1 to 20 ft/s) Wide turndown ratio of 20:1 Highly repeatable output Simple, economical design Installs into pipe sizes
More informationSignet DryLoc ph/orp Electrodes
Signet 2774-2777 DryLoc ph/orp Electrodes Features Patented DryLoc connector with gold plated contacts* Special design allows for installation at any angle, even inverted or horizontal Quick temperature
More informationFM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017
FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 Maxi-Tronic, Inc. 417 Wards Corner Road Loveland, OH 45140 513.398.2500 800.659.8250 FAX: 513.398.2536 info@maxitronic.com
More informationHarbor Light Model HL General Specifications
Harbor Light Model HL30100 General Specifications Rev.5 02-02-17 Marina Electrical Equipment, Inc. 100 Warwick Court Williamsburg, VA 23185 Toll Free: 1-855-258-3939 Fax: 1-757-258-3988 ALL HARBOR LIGHT
More informationInstallation and Operation Instructions DLP Series
Installation and Operation Instructions DLP Series PRECAUTIONS Figure 1: DLP Dimensions and Hardware REMOVE POWER BEFORE WIRING. NEVER CONNECT OR DISCONNECT WIRING WITH THE POWER APPLIED. DO NOT ALLOW
More informationSignet ph/orp Electrodes
Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Glass Protected Bulb Patented reference design for exceptional performance * Mounts in Signet standard fittings
More informationSignet V(D) to V(D) PVDF Conductivity Electrodes
Signet 2839-1V(D) to 2842-1V(D) PVDF Conductivity Electrodes Features ± 2% accuracy - Custom calibration certificate provided Dual-threaded Compact electrode length for easy in-line installation in small
More information32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide
32XR 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide RED ALARM LIGHT LEVEL CONTROLLER H-O-A SWITCHES HORN SILENCE INNER DOOR MOTOR STARTERS WITH INTERCHANGEABLE OVERLOAD MODULES
More information2100 Turbine Flow Sensor
200 Turbine Flow Sensor Description Engineered specifically for small pipe diameter applications, the Signet 200 Turbine Flow Sensor provides accurate readings in two flow ranges: 0.3 to 3.8 lpm and 3
More informationRESISTIVITY MONITOR/CONTROLLERS
RESISTIVITY MONITOR/CONTROLLERS Installation Operation Maintenance User Manual for Models: 750, 752, 753, 762 2450 Impala Drive Carlsbad, CA 92010-7226 USA Tel: 1-760-438-2021 Fax: 1-800-869-7668 / 1-760-931-9189
More information14x12x7 Inch 48 VDC (PoE) Power-Over-Ethernet Powered, Weatherproof & Insulated with Heating System - Model: NB H0N
14x12x7 Inch 48 VDC (PoE) Power-Over-Ethernet Powered, Weatherproof & Insulated with Heating System - Model: NB141207-4H0N Applications and Features Features: Molded Fiberglass Reinforced Polyester (FRP)
More informationchannel bracket 1.50 (38) flat strap shaded area is useable space
Electrical JIC Terminal Strap Kit JIC Terminal Strap Kits fit all styles and types of JIC enclosures. The kits are furnished with flat straps for mounting Flat Based Terminal Blocks, (see Flat Based Terminal
More information* * Signet 2450 Pressure Sensor. Product Manual. English. Description. Dimensions Rev /18
English Signet 2450 Pressure Sensor *32450.0901* 32450.0901 Rev. 13 03/18 Product Manual Description The 2450 Pressure Sensor has a onepiece injection molded PVDF body and ceramic diaphragm for superior
More informationSignet ph/orp Transmitter
Signet 87501 ph/orp English *38750.0901* 38750.0901 Rev. F 3/06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.
More informationTemperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A
Temperature Control Panel Wiring Diagram Model: ISPA-0-P-5A Shift Controls, Inc. Installed Options: TC Jack Panel Connector Interlock Relay, RLY- 5A Power Cord www.shift-controls.com support@shift-controls.com
More informationSignet 3719 ph/orp Wet-Tap Assembly
Signet 3719 ph/p Wet-Tap Assembly Features Electrode removal without process shutdown Space saving 45 mm (1.75 in.) short-stroke design Sealed pneumatic dampening for smooth and safe operation SafeLoc
More informationType Electrically Actuated Ball Valve
GF Piping Systems Electrically Actuated Ball Valve Type 179-184 General Size: ⅜ 4 Material: PVC, CPVC, PROGEF Standard PP, ABS, SYGEF Standard PVDF Seat: PTFE Seals: EPDM, FPM End Connection: Solvent cement
More informationRobust construction and high amperage capabilities
DR Features and Ratings p. 94 DR30 p. 95 DR50 p. 97 DR100 p. 99 DR150 p. 101 DR 250 p. 103 DR400 p. 105 Spare parts p. 107 Dimensions p. 109 Robust construction and high amperage capabilities DR series
More informationCENTRIFLOW METER and ELECTRONICS WIRING and INSTALLATION MANUAL REV 01/16 ORIGINAL LANGUAGE Copyright 2016 Eastern Instrument Laboratories, Inc. All Rights Reserved. TABLE OF CONTENTS SAFETY Safe Operation...
More informationSwitch rated plugs and receptacles with nema 4X protection
DSn Features and Ratings p. 24 DSN20 p. 25 DSN30 p. 27 DSN60 p. 29 Spare parts p. 31 Dimensions p. 33 23 Switch rated plugs and receptacles with nema 4X protection DSN Series products are switch and hp
More informationResidential Transition Box. Model RU-1. Specifications. Electrical
Residential Transition Box Model RU-1 Model RU-1 transition box provides a quick, simple, and easy transition between a microinverter trunk cable and stranded wire. Using only a single flathead screwdriver,
More informationPhone: Fax: Web: -
control series The larger ontrol Series offers standard features as well as full-panel access and all usable panel space. In addition, the standard grey cover is available with or without a full-length
More informationSolar Combiner Solutions
Combiner Solutions Built to UL1741 standards NEMA 4X (fiberglass and stainless steel) NEMA 3R (painted steel) Made in America Combiners and disconnects that offer superior resistance and durability from
More informationSwitch rated plugs and receptacles
DS Features and Ratings p. 36 DS20 p. 37 DS30 p. 39 DS60 p. 41 DS100C p. 43 DS100 p. 45 DS200 p. 47 Spare parts p. 49 Dimensions p. 51 35 Switch rated plugs and receptacles DS Series Decontactors provide
More informationPhone: Fax: Web: -
empire SERIES For your largest applications, turn to the Empire Series from Allied Moulded. Fiberglass construction offers durability and strength without the excessive weight of a comparable metal enclosure.
More informationACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:
ACCUVALVE MODEL AVC6000 SUBMITTAL MODEL CODE WARNING: NOT FOR USE WITH PERCHLORIC ACID MATERIALS VALVE HOUSING MATERIAL 2 = 304SS, 20 GAUGE 3 = 316SS, 20 GAUGE 4 = ALUMINUM, 16 GAUGE 6 = HIGH TEMP 304SS,
More informationPanel Size. Conductive
Spec-00402 ULTRX, Type 4X INDUSTRY STANDARDS Mounting brackets required to meet UL/CSA external mounting requirements. UL 508A Listed; Type 3, 3R, 4, 4X, 12, 13; File No. E697 cul Listed per CSA C22.2
More informationRobust construction and high amperage capabilities
DR Features and Ratings p. 130 DR30 p. 131 DR50 p. 133 DR100 p. 135 DR150 p. 137 DR 250 p. 139 Spare parts p. 141 Dimensions p. 143 Robust construction and high amperage capabilities 129 DR series plugs
More information30 ma Ground Fault (Earth Leakage) Modules. Product Description
August 2006 0 ma Ground Fault (Earth Leakage) Modules 5-0 ma Ground Fault (Earth Leakage) Modules Clockwise from Left:,, MCCBs Shown with Ground Fault (Earth Leakage) Modules Product Description Eaton
More informationLIMIT SWITCHES & POSITION INDICATION
LIMIT SWITCHES & POSITION INDICATION Engineering Creative Solutions for Fluid Systems Since 1901 TECHNOPOLYMER LIMIT SWITCH DESCRIPTION The Pratt Industrial MS41-2 Limit Switch Box represents a new dimension
More informationSIGNET 2750 ph/orp Sensor ENGLISH
ENGLISH 3-2750.090 B-8/01 English SAFETY INSTRUCTIONS FOR IN-LINE ELECTRODE INSTALLATION 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifications. 3. Wear safety
More informationSignet Pressure Transmitter
Signet 80 Pressure 80.090 80.090 Rev. J 0/ English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation.
More informationPlug and Play Kit Installation and Wiring (Non-Combo and Combo)
General Information This publication is to be used for Eaton Plug and Play enclosures designed starters that accept the M22 series 22mm cover control devices. To install the cover control kit (Follow the
More informationThe TeleControl Series Technical Drawings
The TeleControl Series Technical Drawings TeleControl TeleControl Enclosures Dimensions SIZE ID NUMBER OVERALL H X W X D INSIDE A X B X C E X F J K L M N HOLE DIA. SHIPPING WEIGHT PANEL NUMBER J1407TC
More informationELECTRICAL INSTALLATION
ENCLOSURE DIMENSIONS NOTES (3) 3/4" NPT WALL MOUNT BRACKET, (2) 5/16" DIA. THRU - HARDWARE IS CUSTOMER SUPPLIED 1¼" NPT AUTO-TEST OPTION 6.312" 160.3 mm 4.85" 123 mm 3.90" 99 mm 4.95" 126 mm 4.85" 123
More informationVA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators
VA-640GSX024P Datasheet Large Globe Actuators Overview The VA-640GSX024P Electronic valve actuators receive a 0 to 10 VDC or 4 to 20 ma control signal to proportionally control the valve. Applications
More informationThe DiamondShield Series DS
The DS The was developed for design flexibility and pleasing aesthetics. Applications include high-end electronics, harsh corrosive environments, and industrial applications both indoors and out. Unique
More information* * Rev. F 03/16 Operating Instructions
English Signet 2552 Metal Magmeter *3-2552.090* 3-2552.090 Rev. F 03/16 Operating Instructions 3-2552-2 3-2552-3 Description The Signet 2552 Metal Magmeter from Georg Fischer features all-stainless steel
More informationAdvanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A
Automation, Inc. Model EAC1100 /A QUICK INSTALL GUIDE Advanced Outdoor Airflow Control, DCV Control and Alarm Solution Enhancer QUICK INSTALL GUIDE for ENHANCER Advanced Outdoor Airflow Control, DCV Control
More informationSignet ph/orp Electrodes
Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Patented reference design for exceptional performance * Mounts in Signet standard fittings from DN15 to DN100 (½
More informationSeismic Sensor Accessories SA, SV & ST 6000 Series
Seismic Sensor Accessories SA, SV & ST 6000 Series Part Number Name Used With Description Housing Material 7295-002 Accelerometer EP Housing SA6200A-X0X; SV6300A-001 Physical protection and access to 1/4-28
More informationSignet 2552 Metal Magmeter
Signet 2552 Metal Magmeter *3-2552.090* 3-2552.090 Rev E 07/10 English English SAFETY INSTRUCTIONS 1. Depressurize and vent systems without Hot-tap valve prior to installation or removal. 2. Confirm chemical
More informationTechnical Features Flow Monitor Part No. Wire Associated Sensor 4-20 ma Digital Relay Power Tech. Sensor Input Output Output Output F9.00.L 2 wire Hal
FLOWX3 F9.00 Flow F9.00 FLS FLOWX3 F9.00 Flow Monitors & Transmitters are designed to convert the signal from all FLOWX3 flow sensors into a display indication and a 4-20 ma signal for long distance transmission.
More informationSignet 2552 Metal Magmeter
Signet 2552 Metal Magmeter *3-2552.090* 3-2552.090 Rev D 06/08 English English SAFETY INSTRUCTIONS 1. Depressurize and vent systems without Hot-tap valve prior to installation or removal. 2. Confi rm chemical
More informationAnalog Condensate Monitor Instruction & Maintenance Manual
Analog Condensate Monitor Instruction & Maintenance Manual Advantage Controls, Inc. PO Box 1472 Muskogee, OK 64402 Phone: 800-743-7431 Fax: 888-686-6212 www.advantagecontrols.com EE-13 email: aci@advantagecontrols.com
More informationAccuPower AQU126B Installation Instructions
Tel 1.800.MAGLOCK info@securitron.com 1.800.624.5625 www.securitron.com AccuPower AQU126B Installation Instructions Recommended Tools & Additional Materials #2 Phillips Screw Driver Wire connectors Lead
More informationDPU90-WM, FP90UM, FP90IM, PHTX-27G, PHTX-275G, FPM-5000-LTCK, FPM-5000-MB
User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info Shown with DPU91 Transmitter (sold separately) DPU90-WM, FP90UM, FP90IM, PHTX-27G, PHTX-275G,
More informationElectric Actuators Maximum in-lbs
Maximum 14040 in-lbs NEMA 4, 4X, 7 ER- Series Features ISO / DIN valve interface Mounting in any position Thermal overload protection (AC & DC except 12 VDC) Friction brake (standard for AC motors except
More informationCompact Low Pressure Sensor
Overview The Low Pressure Sensor is a true differential pressure transmitter that provides ±1 inches WC (±250 Pacals) in 10 field selectable ranges (see specifications). The enclosure is designed for DIN
More informationmass flowmeter for compressed air
mass flowmeter for compressed air VARIOMASS ECO pressure and temperature compensated easy and cost effective installation of the sensor no pressure loss caused by the sensor no moving parts, i.e. maintenance
More informationElectric Actuators Maximum in-lbs
Maximum 14040 in-lbs NEMA 4, 4X, 7 ER- Series Features ISO / DIN valve interface Mounting in any position Thermal overload protection (AC & DC except 12 VDC) Friction brake (standard for AC motors except
More informationC1000 Series Automatic Cap Bank
C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution
More informationFROG-D 3P. FREQUENCY READOUT OF GENERATOR THREE PHASE GENERATOR DISPLAY MODELS: FDA700 for Delta Winding FDA710 for Star Winding
Document Number: XE-FDA7PM-R0A FDA700 Rev160509 FROG-D 3P FREQUENCY READOUT OF GENERATOR THREE PHASE GENERATOR DISPLAY MODELS: FDA700 for Delta Winding FDA710 for Star Winding FIRE RESEARCH CORPORATION
More informationSignet Measurement and Instrumentation
F Piping Systems Signet Measurement and Instrumentation Price List effective January 1, 2018 NEW! DryLoc ph/orp Smart Sensor Electronics See page 37 for new lower pricing on Portaflow Ultrasonic Flow Meters!
More informationDSN. Switch-rated plug and receptacle with Type 4X protection
DSN Features and Ratings p. 24 DSN20 p. 25 DSN30 p. 27 DSN60 p. 29 DSN150 p. 31 Spare parts p. 33 Dimensions p. 35 Switch-rated plug and receptacle with Type 4X protection DSN Series products are switch
More informationDIN Rail Mounting Bracket
DIN Rail Mounting Bracket Fits Simpson Hawk 3, Falcon and Counters Fits Standard Din Rail C 1 4.30 2.55 3.85 Din Rail Adapter 44 Enclosure: Attachment Clips: Stiffeners: Installed depth: UL94V-0 Rated
More informationModel 550 Series Vibration Switches
OPERATION MANUAL Vibration Switches Includes: 550 550M 550-X 550M-X Page 2 SECTION TITLE PAGE 1. INTRODUCTION... 2 2. FEATURES... 3 3. WIRING... 4 4. ANALOG METER... 4 5. TESTING... 4 6. INSTALLATION...
More informationStandard Product. Wall-Mount Cabinets ULTRX Fiberglass Type 4X WiFi Cabinet and Accessories
Spec-00144 Wall-Mount Cabinets ULTRX Fiberglass Type 4X WiFi Cabinet and Accessories ULTRX WiFi, Type 4X INDUSTRY STANDARDS UL 508A Listed; Type 4, 4X, 12, 13; File No. E61997 cul Listed per CSA C22.2
More informationSignet 2551 Magmeter Flow Sensor
Signet 2551 Magmeter Flow Sensor Available in a variety of wetted materials and ideal for pipe sizes up to DN900 (36 in.) Features Test certificate included for -X0, -X1 Patented Magmeter technology No
More informationFrom. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)
SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and
More informationBASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.
BASIC Data Sheet No. B-699 IN-LINE LIQUID FLOW RATE MONITORS CHOICE OF THREE MATERIALS OF CONSTRUCTION Select from aluminum, brass or stainless steel to meet system and liquid requirements. UNRESTRICTED
More informationAccutrol, LLC Product Sheet H-AVC5000. US Patents 6,991,177 & 7,543,759. Specially Made for Vivarium Cage Racks
Accutrol, LLC Product Sheet Cage Rack Valve H-AVC5000 US Patents 6,991,177 & 7,543,759 Specially Made for Vivarium Cage Racks Exceptionally Low Pressure Drop Design System Pressure as low as 0.05" (12.5
More informationSYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN
SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT
More informationSolenoid Valves & Accessories. Incorporating Solenoid Valves in. Custom Products. Solenoid Operated. Custom Products
PNEUMADYNE, INC. Catalog 24 Phone 763-559-177 Fax 763-559-547 Incorporating Solenoid Valves in Custom Products For over 3 years, manufacturers have relied on Pneumadyne for innovative solutions to their
More informationSolid Dielectric, Single Phase Recloser
Solid Dielectric, Single Phase Recloser Catalog O-vsp17 Viper-SP Viper-SP solid dielectric, single phase recloser combines the time-proven reliability of electronically controlled, vacuum fault interrupters
More informationSize: 1/4 to 3. Material: 316 Stainless Steel, Carbon Steel,
Size: 1/4 to 4 Material: 316 Stainless Steel, Carbon Steel, Alloy 20, Hastelloy C, Monel, Brass, SW, BW, BSPT, 150#, 300#, 600#, Flanged Pressure: Vacuum to 3000 PSI* -50 to 600 F* ASME B16.34 Design Bottom
More informationSignet 3719 ph/orp Wet-Tap
Signet 3719 ph/orp Wet-Tap *3-3719.090* 3-3719.090 Rev H 09/07 English Do not exceed maximum temperature/pressure specifications. Wear safety goggles or face shield during installation/service. Do not
More informationNEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry
NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW preliminary information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. www.usa.siemens.com/controls
More informationD2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments
D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal
More informationLIMIT SWITCH BOX MODEL - APL
FEATURES AND BENEFITS Enclosure -Solid design, aluminium die-casting IP67 Painting-Powder coating Housing Body- Aluminium die-casting Quick-set Cam-Easy to set, Splined cam Open Yellow, Close Red Various
More informationULTRX, Type 4X. Panel Size. Conductive
Spec-00402 EPH FX (763) 422-2600 422-21 Non-Metallic Fiberglass Industry Standards Mounting brackets required to meet UL/CSA external mounting requirements. UL 508A Listed; Type 3, 3R, 4, 4X, 12, 13; File
More informationAD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation
592 Theory of Operation The 592 sensor is a two terminal integrated-circuit temperature sensor. The 592 provides an output current directly proportional to absolute temperature. When the temperature of
More informationElectric Actuator Instructions
BAC IOM Electric Actuator Instructions E024, E025, E026, E029 & E030 TABLE OF CONTENTS Electric Actuator Specifications...2 Overview...3 Actuator Wiring Diagrams...4 VMS-35 Specifications and Wiring Diagram...5
More information^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband
P-SERIES Temperature Switches Switches for -30 through 5 F with Adjustable Set Points and Fixed or Adjustable Features: Set point repeatability, + F (/2 C). All wiring terminals, adjustments and visual
More informationSYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN
SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT
More informationGRANITE ENCLOSURES MODEL NO. NPS Standard Features
MODEL NO. NPS-6-- --0666 Standard Features CSA and NEMA 3R (UL50) 1800 Amps @ 24Volt / 900 Amp @ 48Volt back up power Solid steel frame and shelf construction with 2 high sub-frame platform. Available
More informationTable of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...
Table of Contents 1. OVERVIEW... 2 2. OPERATION FUNCTION... 2 3. SPECIFICATIONS... 3 4. INSTRUM LAYOUT... 4 4.1 OPERATION KEY...4 4.2 INDICATORS...4 5. INSTALLATION... 5 5.1. ENVIRONM CONDITIONS...5 5.2
More informationGF Piping Systems. Stress Less. Pipe and Valve Support System Finally, just for plastic pipe. Patents issued and pending
GF Piping Systems Stress Less Pipe and Valve Support System Finally, just for plastic pipe Patents issued and pending Problem Improper piping system support can result in premature Traditional piping supports
More informationMULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers
IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when
More informationIDEM Solenoid Interlock Safety Switches
KLP/KLM/KL3-SS Series Housing Solenoid locking, tongue (key) interlock operated Power to unlock 90 degree adjustable head One (KLP) or three (KLM, KL3-SS) 1/2 in. female NPT conduit opening 30mm mounting
More information