COMBUSTION AND ENERGY

Size: px
Start display at page:

Download "COMBUSTION AND ENERGY"

Transcription

1 CATALOGUE 2015 COMBUSTION AND ENERGY COMBUSTION AND ENERGY SRL VIA PER DOLZAGO, OGGIONO (LC) - ITALY - PH FAX

2 INTERNATIONAL STANDARDS The ATEX directive consists of two EU directives describing what equipment and work environment is allowed in an environment with an explosive atmosphere. The Federal Aviation Administration (FAA) is the national aviation authority of the United States. An agency of the United States Department of Transportation, it has authority to regulate and oversee all aspects of American civil aviation. The International Civil Aviation Organization, is a specialized agency of the United Nations. It codifies the principles and techniques of international air navigation and fosters the planning and development of international air transport to ensure safe and orderly growth. Competency in Ex atmospheres is a global certification scheme for electrical and mechanical craftspersons and designers working in potentially explosive atmospheres. Safety Integrity Level is defined as a relative level of risk-reduction provided by a safety function, or to specify a target level of risk reduction. International Electrotechnical Commission system for certification to standards relating to equipment for use in EXplosive atmospheres (IECEX system).

3 TECHNICAL EJB SPECIFICATIONS Material: SS316 or aluminium Degree of protection: IP66 Temperature: -50 C to +60 C Standards: EN : 2009 / : 2007 / : 2009 IEC : 2011 / : 2007 / :2008 Ex Code: II 2 GD Ex d IIB T6/T5/T4 Gb Ex tb IIIC T85 C / T100 C / T135 C Db IP66 In accordance with the European Directive 94/9/EC (ATEX) for Zone1 / Zone2 / Zone 21 / Zone 22 Threaded Holes: Metric thread 1.5 / NPT Certificate Number: INERIS 14ATEX0002X IEC.Ex INE X STRONG POINTS Laminated lid: more operative surface and flexibility Primary melting alloy Hinges available on long/short side Windows available on all boxes dimensions RFID/NFC tracking (Radio-frequency identification tag)

4 ALUMINIUM EJB DIMENSIONS TYPE EJB-A EJB-B EJB-C EJB-D EJB-E EJB-F EJB-G HEIGHT (H) EXTERNAL DIMENSIONS WIDTH (W) DEPTH (D) HEIGHT (H1) INTERNAL DIMENSIONS WIDTH (W1) DEPTH (D1) INTERNAL PLATE A FIXING HOLES WEIGHT FEET FIXING BOLTS B U T kg ØZ ,5 227,5 163, ,9 M ,1 M , ,6 M ,5 380, , ,7 M8 593, ,2 M ,8 M ,1 M10 EJB-H ,9 M10 All dimension are in mm. Dimensions and weight subject to change without any notice.

5 ALUMINIUM Ex ENCLOSURES BOTTOM VIEW INTERNAL PLATE A W1 D1 H1 H T B ø Z U FRONT VIEW SIDE VIEW D W COMBUSTION AND ENERGY - info@ce2k.com Ph Document is subject to change without any notice

6 STAINLESS STEEL 316L EJBS DIMENSIONS EXTERNAL DIMENSIONS INTERNAL DIMENSIONS INTERNAL PLATE FIXING HOLES WEIGHT FEET FIXING BOLTS TYPE HEIGHT (H) WIDTH (W) DEPTH (D) HEIGHT (H1) WIDTH (W1) DEPTH (D1) A B U T kg ØZ EJBS-A M10 EJBS-B M10 EJBS-C M10 EJBS-D M10 EJBS-E M16 EJBS-F M16 EJBS-G M16 EJBS-H M16 All dimension are in mm. Dimensions and weight subject to change without any notice.

7 STAINLESS STEEL 316L ENCLOSURES BOTTOM VIEW INTERNAL PLATE A W1 ø Z B U FRONT VIEW SIDE VIEW D1 T H H1 W D COMBUSTION AND ENERGY - info@ce2k.com Ph Document is subject to change without any notice

8 SPECIFIC EJB FEATURES S.NO. INERIS 14ATEX0002X CE 0080 Ex d IIB T...Gb II2GD Ex tb IIIC T... Db IP66 Via per Dolzago, Oggiono (LC) Italy EJB(*) U N =... V AC... HZ/DC T. amb. (**) P. dis.max.(***) W T. cable (****) Year of construction: Cable entries: See instructions S.NO. IECEx INE X Ex d IIB T... Gb Via per Dolzago, Oggiono (LC) Italy EJB.. U N =... V AC... HZ/DC T. amb. (*) P. dis.max.(**)w Ex tb IIIC T... Db IP66 T. cable (**) Cable entries: See instructions Warnings: DO NOT OPEN WHEN ENERGIZED DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT. TYPE OF ENCLOSURES (*) EJB-A EJBS-A EJB-B EJBS-B EJB-C EJBS-C EJB-D EJBS-D EJB-E EJBS-E EJB-F EJBS-F EJB-G EJBS-G EJB-H EJBS-H MAX. AMBIENT TEMPERATURE (**) Gas T6 Dust T85 C MAXIMUM POWER DISSIPATED(***) 40 C 50 C 60 C CABLE TEMPERATURE (****) 80 W 60 W 35 W NC T5 T100 C 120 W 95 W 75 W 95 C T4 T135 C 205 W 180 W 155 W 135 C T6 T85 C 125 W 90 W 55 W 85 C T5 T100 C 180 W 145 W 110 W 100 C T4 T135 C 305 W 270 W 235 W 135 C T6 T85 C 210 W 150 W 95 W 85 C T5 T100 C 295 W 235 W 180 W 100 C T4 T135 C 500 W 440 W 380 W 135 C T6 T85 C 255 W 185 W 115 W 85 C T5 T100 C 360 W 290 W 220 W 100 C T4 T135 C 610 W 535 W 465 W 135 C T6 T85 C 275 W 200 W 125 W 95 C T5 T100 C 390 W 315 W 240 W 115 C T4 T135 C 655 W 580 W 505 W 160 C T6 T85 C 365 W 265 W 165 W 95 C T5 T100 C 515 W 415 W 315 W 115 C T4 T135 C 850 W 755 W 660 W 160 C T6 T85 C 430 W 315 W 195 W 95 C T5 T100 C 610 W 495 W 375 W 115 C T4 T135 C 1020 W 905 W 790 W 160 C T6 T85 C 535 W 390 W 245 W 95 C T5 T100 C 610 W 460 W 320 W 115 C T4 T135 C 1260 W 1120 W 975 W 160 C

9 TABLES NUMBER OF THREADED HOLES AND OPERATORS ON FRONT EJB Type A B C D E F G H Nr. of threaded holes and operators (M32 and M25) NUMBER OF HOLES ON LONG/SHORT SIDE FOR EACH EJB ENTRY A B C BOX TYPE D E F G H M20 1/2 8/6 12/6 20/16 24/22 30/24 55/26 55/32 60/38 M25 3/4 8/4 6/2 12/9 22/16 25/20 38/18 40/22 44/24 M32 1 3/2 3/2 10/8 11/9 13/11 30/15 34/18 36/20 M50 1.1/2 2/1 2/1 4/3 8/8 8/8 14/6 16/12 17/13 M63 2 3/2 3/3 4/4 10/4 11/5 12/6 M75 2.1/2 2/2 2/2 3/2 4/2 6/4 6/4 M80 3 1/1 2/2 3/1 5/3 5/3 COMBUSTION AND ENERGY - info@ce2k.com Ph Document is subject to change without any notice

10 ATEX CERTIFICATE

11 IEC.Ex BODY CERTIFICATE COMBUSTION AND ENERGY - info@ce2k.com Ph Document is subject to change without any notice

12 Ex d IIC GUB ENCLOSURES FEATURES TECHNICAL SPECIFICATIONS Material: Aluminium Degree of protection: IP65 Temperature: -20 C to + 40 C or -20 C to + 70 C Standards: EN / IEC / Ex Code: Ex II 2G Ex d IIC T6/T4 Compliant with the European Directive 94/9/EC (ATEX) for Zone 1 / Zone 2 Threaded Holes: Metric thread 1.5, ANSI B NPT, UNI 6125 Windows (option): Borosilicate Tempered Glass Certificate Number: INERIS 03ATEX0174X MANUFACTURER Combustion and Energy Srl Part number: Gub.. Gub..W

13 Ex d IIC GUB ENCLOSURES DIMENSIONS EXTERNAL DIMENSIONS INTERNAL DIMENSIONS WEIGHT GLASS WINDOW (Option) TYPE HEIGHT (H) WIDTH (W) LENGHT (L) HEIGHT (H1) WIDTH (W1) LENGHT (L1) kg mm GUB 1 GUB 2 GUB L W W1 H1 H L1 COMBUSTION AND ENERGY - info@ce2k.com Ph Document is subject to change without any notice

14 ATEX CERTIFICATE

15 COMBUSTION AND ENERGY SRL Address: Via Per Dolzago, Oggiono (LC) - ITALY Legal office: Via Ponchielli, Milano (MI) - ITALY Ph info@ce2k.com info@luxsolar.com Web: are trademarks of COMBUSTION AND ENERGY

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES Ex d IIB+H 2 ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES ALUMINIUM ENCLOSURES STAINLESS STEEL ENCLOSURES EJB... series enclosures offer Ex d IIB +H 2 mode of protection. These enclosures are

More information

Solutions Ex d IIB+H2, Aluminum and Stainless Steel

Solutions Ex d IIB+H2, Aluminum and Stainless Steel Features Assembly examples Enclosures manufactured from copper-free aluminum or AISI 316L stainless steel Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d IIB+H2 and Ex tb More than 40 enclosure

More information

Solutions Ex d IIB+H2, Stainless Steel EJBX*

Solutions Ex d IIB+H2, Stainless Steel EJBX* Features Assembly Examples Enclosures manufactured from AISI 316L stainless steel Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d IIB+H2 and Ex tb More than 20 enclosure size options Free

More information

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C Enclosures Flameproof - Group IIB or IIB + 2 Carbon steel - DE8BC series The flameproof control cabinets DE8BC are designed for the control, automation, distribution boards, motor starters or any other

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C... EJB Enclosures ATEX and IECEx Zone 1 certified Explosion proof Marine grade copper-free aluminium IP66 The EJB Series is a range of explosion-proof enclosures, available in either aluminium alloy (EJB)

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE

More information

CCAI, CCAIF, CCAIF..H

CCAI, CCAIF, CCAIF..H CCAI, CCAIF, CCAIF..H - Zone 1, 2, 21, 22 - Group IIC - Stainless steel junction boxes - Choice of 4 sizes - IP66 AISI 316L stainless steel Grub screws for opening lid Lid opening system Detail of inside

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

Floodlight LED Series 6125

Floodlight LED Series 6125 www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated

More information

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 www.atos.com Table TF040-2/E Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 A B DHRZO-A-012/25 A B DHRZA-A-010/25 DHRZ* are

More information

Solenoid coils VACF Type codes

Solenoid coils VACF Type codes Solenoid coils VACF Type codes VACF B B2 1A Type VACF Solenoid coil, F series Solenoid coil type A B Width 30 mm, for 8 mm armature tube Width 22 mm, for 8 mm armature tube A1 Connection pattern type A,

More information

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67. EJB Stainless steel bolts - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67 Mounting bracket Hinges in stainless steel Warning labels Silicone gasket between

More information

Emergency Light Fitting for Fluorescent Lamps Series 6009

Emergency Light Fitting for Fluorescent Lamps Series 6009 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or

More information

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L Temperature Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L WIKA data sheet TE 60.12 for further approvals see page 2 Applications Chemical industry Petrochemical

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder

More information

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67. Ex d EJB Stainless steel bolts - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67 Mounting bracket Hinges in stainless steel Warning labels Silicone gasket

More information

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L Temperature Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L WIKA data sheet TE 65.12 for further approvals see page 2 Applications Chemical industry Petrochemical industry

More information

Linear luminaire with LED Series EXLUX 6002

Linear luminaire with LED Series EXLUX 6002 > latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1 www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic

More information

Terminal Boxes Series 8125

Terminal Boxes Series 8125 Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet painted > basic enclosure sizes various heights > Fitted according to the customer's requirements

More information

Terminal Boxes in Stainless Steel SLS**.T

Terminal Boxes in Stainless Steel SLS**.T Features Variant options Stainless steel enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 6 enclosure size options Various terminal and cable gland configurations

More information

New products Ex Equipment 2015

New products Ex Equipment 2015 New products Ex Equipment 2015 ROSE Systemtechnik GmbH ROSE Systemtechnik GmbH was founded in Porta Westfalica, Germany, in 199 and is today one of the world s leading and innovative providers of industrial

More information

ABG Cable Glands Installation Procedure

ABG Cable Glands Installation Procedure ABG Cable Glands Installation Procedure ABG Cable Gland Range Baseefa 16ATEX0004X IECEx BAS 16.0011X Installation, Operation and Maintenance Instructions Material: Brass/ Brass with Nickel plated and Stainless

More information

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Sheet-Steel Light Fittings Series 6114/1 > As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive

More information

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR) WELLGLASS EV.. Series - H.I.D. well glass lighting fixture EV.. series well glass lighting fixtures are suitable for hazardous areas of industrial plants for lighting of indoor and outdoor structures,

More information

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6002 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch

More information

Floodlight LED Series 6525

Floodlight LED Series 6525 www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless

More information

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series Ex d S S.1 series - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67 SSC series Temperature sensor box SWS series SF series A.117 S... series Junction boxes

More information

Load disconnect switch Series 8146/5-V11

Load disconnect switch Series 8146/5-V11 www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation

More information

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A .1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility

More information

EX-D ENCLOSURES AND DISTRIBUTIONS

EX-D ENCLOSURES AND DISTRIBUTIONS EX-D ENCLOSURES AND DISTRIBUTIONS Series GHG made of metal for gases of explosion group IIC To use MCBs, fuses, contactors etc. which give off arcs in potentially hazardous areas, they must be integrated

More information

Control Stations CP.../EFDCN

Control Stations CP.../EFDCN CP.../EFDCN The CP EFDCN range of control stations are based on the features of our CP enclosure, which offers an Ex d IIC mode of protection with or without accessories (push buttons, selector switches,

More information

Hazardous Area Electrical Equipment. TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22. Index

Hazardous Area Electrical Equipment. TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22. Index Hazardous Area Electrical Equipment Made TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22 Index Dimension Sheet Catalogue Information Leaflet Web Links TBKF/CBKF Information Page

More information

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Characteristics limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Standard format Product or component type Limit switch Device short name XCKJ

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

Control Buttons / Switches for Panel Mounting Series 8003

Control Buttons / Switches for Panel Mounting Series 8003 www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch > 2 contact elements > Spring clamp

More information

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22) .7 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial separation

More information

PY, SPY; FSQC, FP; EPC; AP

PY, SPY; FSQC, FP; EPC; AP Ex d PY, SPY; FSQC, FP; EPC; AP Sockets and plugs Aluminium alloy with low copper - Group IIC content - Zone 1, 2, 21, 22 - Aluminium alloy - Ergonomic - Plugs can be used with industrial sockets Polyester

More information

Position Switches Series 8074/2

Position Switches Series 8074/2 www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,

More information

Floodlight Series 6121

Floodlight Series 6121 www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options

More information

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA Mechatronic pressure measurement Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA WIKA data sheet PV 34.38 Applications Pressure monitoring and control of processes

More information

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22 WELLGLASS - EVH, EVX WELLGLASS FITTING - S 1, 2, 21 & 22 127 Wellglass fittings Features Compact design for easy installation For diffuse or ambient light Compatible with energy saving lamps or discharge

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp

More information

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4 1. Introduction: This instruction manual contains important information regarding the safety instructions, installation, operation, maintenance and storage of the Guardbox limit switch boxes. The limit

More information

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22) .6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial

More information

Modular Explosion Proof Brakes. IECLine rev 0

Modular Explosion Proof Brakes. IECLine rev 0 Modular Explosion Proof Brakes IECLine 2013 rev 0 Application example Standard B5 motor + VIS brake Standard B5 motor + VIS brake + gearbox unit Main Characteristics -PATENT pending design and concept

More information

Motors and drives for applications in explosive atmospheres

Motors and drives for applications in explosive atmospheres Motors and drives for applications in explosive atmospheres Certification. Diligence. Reliability. Safety. Everything counts Operating processes in explosive (Ex) atmospheres requires the right mix of

More information

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC > For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking

More information

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /.. d.o.o. tel. 049 222 900, fax 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE 0403.24/.. No: TEPEx.RS.077 Rev : 0 Date: 02.2016. CONTENT 1. Manufacturer

More information

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22) .5 Ex Floodlights for high-pressure discharge lamps, series PX 0 and FLT 10 (Zone 1, 2, 21, 22) The powerful floodlights for harsh environments Thanks to the high degree of protection IP66, the robust

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

TBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22

TBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22 Hazardous Area Electrical Equipment TBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22 Index Dimension Sheet Catalogue Information Leaflet Web Links TBKS/CBKS Information Page Ask

More information

ATEX LABELLING FOR MOTORS AND GEAR UNITS

ATEX LABELLING FOR MOTORS AND GEAR UNITS ATEX LABELLING FOR MOTORS AND GEAR UNITS EN ATEX INFORMATION GAS AND DUST COMPLETE DRIVE SOLUTIONS FROM A SINGLE SOURCE RELIABLE n Reliable products n Coordinated components n NORD's own development and

More information

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Table FX1-/E Replaces F6-5 /E E125-16 /E Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Valve main body Cartridge Mechanical pressure limiter

More information

Integrated Control modules

Integrated Control modules .60.0 Rev. 0 Page of 9 Integrated Control modules QC, QC2 and QC Features: - Basic actuator functions for: - Spring return applications, or - Double acting applications or, - Double acting Fail in Last

More information

VALIADIS S.A. HELLENIC MOTORS

VALIADIS S.A. HELLENIC MOTORS Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe

More information

ILED Dorado. User Manual

ILED Dorado. User Manual 10NM U-code Medium Intensity Obstruction Light Helideck Status Light 15NM U-code Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description...

More information

M-0. M-0... series control, monitoring and signalling devices. Ex e

M-0. M-0... series control, monitoring and signalling devices. Ex e M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere

More information

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators Ex d GRD-4200 Electronic earthing system - Zone 1, 2, 21, 22 - High quality electronic components - High resistance to corrosion and extreme weather - Safe and reliable over time SIL certified Level 2

More information

Linear fluorescent luminaire LED V-CG-S

Linear fluorescent luminaire LED V-CG-S (2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from 75.000 hours Different luminous colours available 4000 K / 5600 K

More information

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION 1. GENERAL INFORMATION The MICROSOL intrinsic safety solenoid valves produced by Fluid Automation Systems SA are dedicated to piloting fluids in explosive atmospheres according to the ATEX 94/9/CE directive,

More information

YFC. Limit switch. Ex d. 24 operating head types

YFC. Limit switch. Ex d. 24 operating head types Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735

More information

Leading the way in hazardous areas Features EATON

Leading the way in hazardous areas Features EATON .2 Ex-escape sign luminaires EXIT for Zone 1 and Zone 21 / Exit 2 for Zone 2 and Zone 22 Moulded plastic version with LED-technique Leading the way in hazardous areas The EXIT series of explosionprotected

More information

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22 Tubular fluorescent fitting XFF - Zones 1, & 1, Features All components mounted on sliding gear tray for easy installation and maintenance Standard components used inside body allowing reduced maintenance

More information

Flameproof Enclosures

Flameproof Enclosures Flameproof Enclosures The range comprises many standard sizes of enclosures manufactured in stainless steel 316L and/or in painted carbon steel. The enclosures allow for utilization of standard electrical

More information

Flameproof Alternators

Flameproof Alternators Overview Standard automotive type alternators are a continuous potential source of ignition when operated in hazardous atmospheres where combustible concentrations of gas, vapor or dusts may exist. To

More information

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22 Tubular fluorescent fitting with automatic switch off Features Quick and easy insulation switch for safe maintenance Ex e integral junction box All components mounted on sliding gear tray for easy installation

More information

ADVANCE- GRP[ GD] S ERIES OP TIMA- EX[ GD] S ERIES

ADVANCE- GRP[ GD] S ERIES OP TIMA- EX[ GD] S ERIES ADVANCE GRP[ GD] S ERIES OP TIMA EX[ GD] S ERIES Plug and socket for applications in potentially explosive atmospheres GAS & DUST [ ATEXIECEx ] II 2GD ADVANCEGRP[GD] Series OPTIMAEX[GD] Seriesimbro ATEXIECEx

More information

JBDA and JBDF ECDA and ECDF Series Customized Enclosures Flameproof

JBDA and JBDF ECDA and ECDF Series Customized Enclosures Flameproof JBDA and JBDF ECDA and ECDF Series Customized Enclosures ATEX/IEC: Zone 1 and 2 21 and 22 II 2 GD IP66 IK10 Applications Designed for use in Zones 1, 2, 21 and 22 in the oil and gas industry such as: Petroleum

More information

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual and Installation Instructions Segurança PSB Heating System Cold applied connection technology Compulsório Type 27-1680-...0/...

More information

Position Switches Series 8060/2

Position Switches Series 8060/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Explosion proof electric motor For Fuel dispensing application. Main characteristic Ad-pe ed.2018/0 1 Explosion proof electric motor For Fuel dispensing application RAEL motori elettrici, since its inception in the late 60s, has assembled more than a million of explosion proof electric

More information

SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS

SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS FOR USE WITH THERMOWELLS II 1G/D Ex ia Pt100RI/WI S10 S11 S16-1 S16-2 1 FEATURES TECHNICAL SPECIFICATION ASSEMBLY The industrial spring loaded configuration

More information

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13 Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.

More information

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps .4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency

More information

Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components

Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components E X - D D I S T R I B U T I O N S with metal EJ enclosures for gases in explosion group IIB Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures.

More information

EWE. Ex de. Cooling fins

EWE. Ex de. Cooling fins EWE Cooling fins - Suitable for installation with ambient temperature from -50 C to +60 C - Suitable for discharge lamps of up to 150W - Suitable for loop-in/loop-out connections - Zones 1, 2, 21, 22 4

More information

LED Linear Luminaire Series EXLUX 6402

LED Linear Luminaire Series EXLUX 6402 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC > For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3

More information

MECAIR PXA/PEX HAZARDOUS PILOTS CLEAN AIR SOLUTIONS PRODUCT LEAFLET

MECAIR PXA/PEX HAZARDOUS PILOTS CLEAN AIR SOLUTIONS PRODUCT LEAFLET PXA/PEX CLEAN AIR SOLUTIONS GENERAL CHARACTERISTICS PROTECTION COIL INSULATION COIL VOLTAGE POWER CONSUMPTION ENCLOSURE ELECTRICAL CONNECTION APPROVALS INERIS II 2 Ex td A21 IP67 T135 C Class H 24 V AC

More information

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Luminaire with LED Series EXLUX 6409/1 > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually

More information

Terminal Boxes TNCN. Explosion protection Marking

Terminal Boxes TNCN. Explosion protection Marking Terminal boxes TNCN Terminal Boxes TNCN The TNCN range comprises many standard sizes of enclosures manufactured in stainless steel 316L for maximum environmental protection. The main box is manufactured

More information

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Resistance thermometer Model TR10-L, Ex d, for additional thermowell Electrical temperature measurement Resistance thermometer Model TR10-L, Ex d, for additional thermowell WIKA data sheet TE 60.12 for further approvals see page 6 Applications Chemical industry Petrochemical

More information

Thermocouple For additional thermowell Model TC10-B

Thermocouple For additional thermowell Model TC10-B Temperature Thermocouple For additional thermowell Model TC10-B WIKA data sheet TE 65.02 for further approvals see page 2 Applications Machine building, plant and vessel construction Energy and power plant

More information

The safety you rely on.

The safety you rely on. Cable Glands Global Solutions Catalogue The safety you rely on. Cable Glands & Accessories Global Solutions Introducing Crouse-Hinds by Eaton The leader in electrical products for hazardous, industrial

More information

Explosion Protected Group IIB Zone 1 Ex d Ring Enclosure Ex e Terminal Boxes Hollow Shaft Option OPERATING SPECIFICATION TECHNICAL DETAILS

Explosion Protected Group IIB Zone 1 Ex d Ring Enclosure Ex e Terminal Boxes Hollow Shaft Option OPERATING SPECIFICATION TECHNICAL DETAILS Ex d Ring Enclosure Ex e Terminal Boxes Hollow Option Ambient Temperature Maximum Throughput Current Protection Mounting (increased range available) 20 rpm (higher on request) 770V ac 1166 Amps In any

More information

Floodlight Series 6521/4

Floodlight Series 6521/4 > The enclosure made of stainless steel V4A, V2A or powder coated sheet steel is available > Broad or narrow beam reflectors and/or asymmetrical lamp fitting > Series 6521/3 explosion protected floodlight

More information

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4 SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4 U 2 1 3 3/2 Series 327 FEATURES The valves are certified according to IEC 61508 Functional Safety data and have SIL-3 capability

More information

Position Switches Series 8070/2

Position Switches Series 8070/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light .4 Ex-Searchlight series SEB 8.., SEB 9.. and SEB 0 (Zone, 2, 2, 22) Portable searchlights for harsh conditions The explosion-protected portable searchlight series SEB 8/9/0 provides a strong and reliable

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

Explosion and flame-proof single phase electric motors

Explosion and flame-proof single phase electric motors Explosion and flame-proof single phase electric motors EEx-d, EEx-de, IIB, IIC II, 2G IP55 II, 2G&D IP66 T4, T5, T6 Frame size 56 to 112 Single phase Voltage 230 50Hz Voltage 265 60Hz Types of mounting

More information

Mechanical features. Spring-loaded elastic terminals: resist vibrations

Mechanical features. Spring-loaded elastic terminals: resist vibrations DXN 20 A 32 A 63 A Explosive atmospheres as standard Compact & robust design Safe & easy operation DXN decontactors are designed for explosive atmospheres, with de protection mode. They comply with the

More information

Spring loaded resistance thermometer

Spring loaded resistance thermometer Spring loaded resistance thermometer THERMOWELL & REPLACEABLE INSERT C200-201-204-205-260-262 CONFIGURATIONS Ex ia RTD Product series PT100RI/WI C200 C201 C204 C205 C260 C262 2 Features assembly The industrial

More information

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings. EATON 1.3.1

CEAG Products Main Catalogue Part 1 Chapter 3. Emergency and safety light fittings.  EATON 1.3.1 CEAG Products Main Catalogue Part 1 Chapter Emergency and safety light fittings www.crouse-hinds.de EATON 1..1 .1..2.1..2 EATON'S CROUSE-HINDS BUSINESS EATON Ex-Signal- and Rettungszeichenleuchten www.crouse-hinds.de

More information

8150 Series Terminal Boxes

8150 Series Terminal Boxes 8150 Series Terminal Boxes TEMINATION eady-term 8150 Terminal Boxes Features Enclosures made of stainless (AISI 304) or (AISI 316L) Optional hinges with cam locks or screws cover Hinged Versions 130 opening

More information