QHSAS APPROVED COMPANY APPROVED COMPANY APPROVED COMPANY. ISO 9001 Quality Management Systems. ISO Environmental Management Systems

Size: px
Start display at page:

Download "QHSAS APPROVED COMPANY APPROVED COMPANY APPROVED COMPANY. ISO 9001 Quality Management Systems. ISO Environmental Management Systems"

Transcription

1 APPROVED COMPANY ISO 9001 Quality Management Systems APPROVED COMPANY QHSAS ISO 1001 Environmental Management Systems APPROVED COMPANY

2 FOREWORD Spell Group started its journey in 19 when two enthusiastic and determined persons met and collaborated. Mr. Chaudhary Muhaad Aslam & Mr. Ali Asghar Malik, from the beginning, knew that this company is going to go places. Alhamdulilah, their untiring efforts, unchanged vision and continuous hard work proved them right. Initially, it was PVC compound they started with. Along the way, working directly with Bata and Servis, their experience grew and they started trading along with manufacturing. A variety of plastics and chemicals were being dealt and a strong emphasize on the iron-handed management was given. Mr. Aslam & Mr. Asghar, from the start, worked on those products which were new to the Pakistan's market. This policy of introducing purposeful and latest products to Pakistan's market has one of the reasons to serve Pakistan and its economy by lowering the burden of imports and saving on gold reserves. We, Chaudhary Muhaad Aslam & Ali Asghar Malik, coit to provide our clients with the quality products and services. May Allah Bless All of Us. Sincerely, Chaudhary Muhaad Aslam Director Ali Asghar Malik CEO

3 QUALITY POLICY It is the policy of Spell Group to produce the fine products of high quality, and on time delivery to meet the custumer s need at competitive prices. This is achieved by using the raw materials of high standard specifications, implementing modern technology, controlled process and appropriate packaging. The top management coits themselves for continuous improvement of the company s quality system, continuous development of its personnel in the fields of technology and research. APPROVED COMPANY ISO 9001 Quality Management Systems APPROVED COMPANY ISO 1001 Environmental Management Systems QHSAS APPROVED COMPANY

4 S. No. Contents Page BS 00 PVC - Insulated Cable (Non-Armoured For Electric Power and Lighting Single Core PVC-Insulated Non Sheathed Cables General Purposes /7 Volts Flexible Conductor Cables Single-Core PVC-Insulated Non-Sheathed Cables /7 Volts PVC-Insulated PVC-Sheathed Cables General Purposes /0 V Single-Core & Circular Twin PVC-Insulated PVC-Sheathed, Light Cable /0 V Conductor Circular Three-Core & Four-Core BS 3 PVC-Insulated Cables For Electricity Supply (Unarmoured & Armoured Cables) Single Core 00/00 V With Circular Stranded Copper or Aluminium Conductors PVC-Insulated 00/00 V Cables With Circular Stranded Copper or Aluminium Conductors Two-Core PVC-Insulated 00/00 V Cables With Circular Stranded Copper or Aluminium Conductors Three-Core PVC-Insulated 00/00 V Cables With Circular Stranded Copper or Aluminium Conductors Four-Core PVC-Insulated 00/00 V Cables With Circular Stranded Copper or Aluminium Conductors Four-Core With Reduced Neutral Conductor Sustained Rating & Associated Voltage Drop of PVC-insulated Power Cables Conductor Resistance Data Rating & Voltage Drop of PVC-Insulated (Armored & Unarmored) single, Twin, Three & Four Core Power Cables With Copper Conductor When Cables Installed in Air Rating & Voltage Drop of PVC-Insulated (Armored & Unarmored) Single, Twin, Three & Four Core Power Cables With Copper Conductor When Cables Installed Direct in Ground Rating & Voltage Drop of PVC-Insulated (Armored & Unarmored) Single, Twin, Three & Four Core Power Cables With Copper Conductor When Cables Run in Single Way Ducts Size Selection Guide Two Core Copper Conductors Size Selection Guide Three and Four Core Copper Conductors Short Circuit Copper Conductor Rating Factors For Cables Installed in Air Rating Factors For Cables Installed in Ground Rating Factor For Depth of Laying Cables Rating Factor For Variation in Thermal Resistivity of Soil Rating & Voltage Drop of PVC-Insulated (Armored & Unarmored) Single, Twin, Three & Four Core Power Cables With Aluminum Conductor When Cables Installed in Air Rating & Voltage Drop of PVC-Insulated (Armored & Unarmored) Single, Twin, Three & Four Core Power Cables With Aluminum Conductor When Cables Installed Direct in Ground Rating & voltage Drop of PVC-Insulated (Armored & Unarmored) Single, Twin, Three & Four Core Power Cables With Aluminum Conductor When Cables Run in Single Way Ducts Size Selection Guide Two Core Aluminum Conductors Size Selection Guide Three and Four Core Aluminum Conductors Short Circuit Aluminum Conductors Useful Information Conversion Factors Tables (Weights and Measurements) Tables (Location Symbols for Installations)

5 BS 00 PVC-Insulated Cables (Non-Armoured) For Electric Power and Lighting 1

6 SINGLE-CORE PVC-INSULATED NON-SHEATHED GENERAL PURPOSES /7 VOLTS PLAIN ANNEALED COPPER CONDUCTOR PVC INSULATED BRITISH STANDARD SPECIFICATION 00 Table cross sectional area of Number and nominal size of wire (s) Radial thickness of insulation Mean overall diameter (upper limit) net weight kg/km Kg 1/ / / / /5.0. 7/ / / / / / / / / / / / / / / /

7 FLEXIBLE CONDUCTOR SINGLE-CORE PVC-INSULATED NON-SHEATHED /7 V SPECIFICATION: PLAIN ANNEALED COPPER CONDUCTOR PVC INSULATED BRITISH STANDARD SPECIFICATION 00 CLASS-5 Table cross sectional area of number and nominal diameter of wires Radial thickness of insulation Mean overall diameter (upper limit) net weight per 0 meter Kg 30/ / / / / / / / / / / / / / /

8 PVC-INSULATED PVC-SHEATHED CABLE GENERAL PURPOSES /0 V SPECIFICATION: PLAIN ANNEALED COPPER CONDUCTOR BRITISH STANDARD SPECIFICATION 00 SINGLE - CORE Table area number and size of wires Radial thickness of insulation thickness of inner covering Radial thickness of sheath Mean Overall diameter Lower Upper Limit Limit weight of cable kg / km 1/ / / / / / / / / CIRCULAR TWIN (ROUND) PVC-INSULATED, PVC-SHEATHED, LIGHT CABLE, /0 V Table / / / / / / / / / /

9 THREE-CORE 1 area PVC-INSULATED PVC-SHEATHED, LIGHT CABLE /0 V CONDUCTOR CIRCULAR number and size of wires BRITISH STANDARD SPECIFICATION 00 Radial thickness of insulation Table thickness of inner covering Radial of sheath thickness Mean Overall diameter Lower Upper Limit Limit weight of cable kg / km 1/ / / / / / / / / / FOUR-CORE 1 Table / / / / / / / / / /

10 BS 3 PVC-Insulated for Electricity Supply (Unarmoured & Armoured Cables)

11 SINGLE-CORE 00/00 V WITH CIRCULAR STRANDED COPPER OR ALUMINIUM CONDUCTORS BS area of Thickness of insulation diameter overall Unarmoured cable weight kg/0m Armour wire diameter (aluminum wire) cable diameter overall Extruded bedding Armoured Taped bedding cable weight with copper kg/km

12 PVC INSULATED 00/00 V WITH STRANDED COPPER OR ALUMINIUM CONDUCTORS BS 3 TWO - CORE 1 area of Thickness of insulation diameter overall Unarmoured cable weight kg/0m Armour wire diameter cable diameter overall Extruded bedding Armoured Taped bedding cable weight with copper kg/km *Shaped Conductors for 5 and above in multicore cables. PVC-INSULATED 00/00 V WITH OR ALUMINIUM CONDUCTORS BS 3 THREE - CORE COPPER 1 area of Thickness of insulation diameter overall 17. Unarmoured cable weight kg/0m 7 Armour wire diameter cable diameter overall Extruded Taped bedding bedding 0. Armoured 0. cable weight with copper kg/km *Shaped Conductors for 5 and above in multicore cables. 8

13 PVC-INSULATED 00/00 V WITH COPPER OR ALUMINIUM CONDUCTORS BS 3 FOUR - CORE area of area of neutral Thickness of insulation cable diameter overall Unarmoured cable weight Armour wire diameter Unarmoured cable diameter overall Extruded bedding Taped bedding cable weight with copper kg/0m kg/km *Shaped Conductors for 5 and above in multicore cables. 9

14 PVC-INSULATED 00/00 V WITH COPPER OR ALUMINIUM CONDUCTORS BS 3 FOUR-CORE (3.5 Core) with Reduced Neutral Conductor area of area of neutral Thickness of insulation cable diameter overall Unarmoured cable weight Armour wire diameter cable diameter overall Extruded bedding Armoured Taped bedding cable weight with copper kg/0m kg/km *Shaped Conductors for 5 and above in multicore cables.

15 SUSTAINED CURRENT RATING & ASSOCIATED VOLTAGE DROP OF PVC INSULATED POWER 11

16 SUSTAINED CURRENT RATINGS AND VOLTAGE DROP OF PVC INSULATED POWER. (UN-ARMOURED & ARMOURED ERA technology is an independent contract research and development organisation and the cable group is part of ERA technology LIMITED. The group has particular experience in thermal of cables in various environment. s given on subsequent pages are the research work of ERA by an international agreed procedures for deriving for cables under many diverse condition of installation and operation. We acknowledge with thanks the use of ERA publication 9.30 part III and IEE requlation 15th edition for compiling current s and voltage drop. The current (ac) of PVC insulated cables given on subsequent pages are given for the three customary methods of installation (1) laid direct in the ground, () laid under ground ducts (3) installed in air for cables having close excess current protection i.e. cables will only be continuously operated at their tabulated if the minimum current at which circuit protection is designed to operate does not exceed times (in case of cables in Air or ducts) or 1.3 times (in case of cables laid direct in the ground) the values given in the table. If this condition is not met see section five of ERA publication EFFECT OF GROUPING OF : For group of circuits the single circuit s apply provided that 1) The horizontal clearance between circuits is not less than twice the over all diameter of an individual cable. ) The vertical clearance between circuits is not less than times the diameter of an individual cable. 3) If the number of circuits exceeds 3, they are in a horizontal plane. Circuits mounted on racks of clears etc where there is free circulation of air around circuits. For conditions other than this, the should be adjusted by suitable factor. STANDARD CONDITIONS: The following conditions have been used to calculate the current s given in the tables. THERMAL RESISTIVITY OF SOIL STANDARD GROUND TEMPERATURE = 1. deg cm/w O = 15 C Depth of burial from ground surface to center of cable to center of duct or to center to trefoil group of cables or ducts. 00/00 Volts Cable = 0.5 m 1.9/3.3 K.V Cables = m VARIATION IN STANDARD CONDITION If there are any variation in standard conditions, reference should be made to factors given on ERA pub Part III Note: FOR INSTALLED IN AND AROUND BUILDING REFERENCES SHOULD BE MADE TO THE IEE PUBLICATION REGULATION FOR THE ELECTRICAL EQUIPMENT OF BUILDING 15TH EDITION. VOLTAGE DROP: According to IEE regulation, the size of every bare or cable shall be such that the drop in voltage from the origin of installation to any point in that installation should not exceed.5% of the nominal voltage when the s are carrying the full load current, but disregarding starting conditions. Values of voltage drop are tabulated for a current of one ere for meter run i.e. for a distance of 1m along the route taken by the cables, and represent along the route taken by the cables, and represent the result of the voltage drops in all the circuit s. For any given run the values need to be multiplied by the length of the run in meters and by the current the cables are to carry, in eres. For three-phase circuits the values tabulated relate to the line voltage and balanced load conditions have been assumed, where the actual current to be carried, i.e the design values of current for the circuit, is significantly less than the tabulated current-carrying capacity, the total voltage drop obtained by the above method is only approximate because the temperature and hence its resistance will be less than those applicable at the tabulated current. Thus for a more accurate assessment, due allowance should be made for the change in resistance with ope temperature. The tabulated values of voltage drop relate to the worst conditions, namely, where the phase angle of the cable circuit is equal to that of the load, For cables up to and including Sq they apply with sufficient accuracy where the power factor of the load lies between 0. lagging and unity and, for larger cables, where the power factor of the load is not worse than 8 lagging in all other cases the value may be unduly conservative and more exact calculation is necessary. If Vd is the voltage drop then Vd = x 1 x L or = Vd x x L When 1 = in eres L = route length in meters = approx / / meters AMBIENT AIR O = 30 C TEMPERATURE TEMPERATURE 1 O = C

17 CONDUCTOR RESISTANCE DATA Resistance of copper and aluminum s for multi-core cables to BS30 Note: 1) Resistance values for copper and aluminum s are shown in Table A. 0 The above formulae strictly apply only when the load power factor is unity. Where the load power factor is not unity the formulae may be used, with reasonable accuracy, for sizes up to. Table A Table B area Maximum resistance of s per km at 0C Temperature Temperature correction factor copper (ohms) aluminium (ohms) O C copper aluminum VOLTAGE DROP An approximate check can be made on voltage drop by means of the following formulae: For d.c and single-phase a.c. two-wire systems: X I X L X R X t 00 For three-phase a.c. systems: 1.73 X I X L X R X t 00 Where I = current in eres L = length of cable run in meters (one only) R = resistance in ohms of one only from Table A t = temperature correction factor from Table B. 13

18 CURRENT RATING AND VOLTAGE DROP 00/00V INSTALLED IN AIR ARMOURED WITH COPPER CONDUCTOR area of cables Spaced per ere Single Core 3 cables Trefoil touching per ere Twin Core per ere * Distance between cable centers up to and including - twice overall diameter of cable 0 and above Three and four cores per ere UNARMOURED WITH COPPER CONDUCTOR area of cables Spaced* 5 volt drop per ere Single Core 3 cables Trefoil touching volt drop per ere Laid flat spaced* volt drop per ere Twin per ere Three and four cores per ere * Distance between cable centers up to and including - twice overall diameter of cable 0 and above

19 CURRENT RATING AND VOLTAGE DROP 00/00V INSTALLED DIRECT IN GROUND ARMOURED WITH COPPER CONDUCTOR area of *.5* cables Touching* per ere Single Core* 3 cables Trefoil touching * Aluminum wire armoured Circular solid s per ere Twin per ere per ere Three and four cores per ere UNARMOURED WITH COPPER CONDUCTOR area of cables Spaced* 5 volt drop per ere Single Core* 3 cables Trefoil touching Laid flat spaced* volt drop per ere volt drop per ere Twin per ere.7 1. Three and four cores per ere * Adjacent cable surfaces seperated by one cable diameter

20 CURRENT RATING AND VOLTAGE DROP 00/00V RUN IN SINGLE WAY DUCTS ARMOURED WITH COPPER CONDUCTOR area of cables Ducts Touching* per ere Single Core 3 cables Ducts touching trefoil toucihing per ere Twin per ere Three and four cores per ere *.5* * Aluminum wire armoured circulate solid s UNARMOURED WITH COPPER CONDUCTOR area of cables Ducts Touching* per ere Single 3 cables Ducts touching trefoil toucihing per ere Twin per ere Three and four cores per ere Trefoil Flat * Aluminum wire armoured circulate solid s

21 SIZE SELECTION GUIDE (BASED ON VOLTAGE DROP OF.5 PER CENT OF 0 V) TWO CORE COPPER CONDUCTORS CURRENT AMPS ROUTE LENGTH METRES 17

22 SIZE SELECTION GUIDE (BASED ON VOLTAGE DROP OF.5 PER CENT OF 15 V) THREE AND FOUR CORE COPPER CONDUCTORS CURRENT AMPS ROUTE LENGTH METRES 18

23 SHORT CIRCUIT CURRENT 00 COPPER CONDUCTOR PVC INSULATION MAX. TEMP. CONTINOUS o SERVICE C MAX. TEMP. SHORT CIRCUIT o 0 C 0 SHORT CIRCUIT CURRENT (KA) ,5 0, 0,3 0,,5 0,1 1,5 0,1 0, 0,3 0, 0,5 1 3 TIME (SEC) 19

24 RATING FACTORS FOR INSTALLED IN AIR o AMBIENT AIR TEMPERATURE 30 C. O The current have been calculated at an ambient air temperature of 30 C. Further more, the s have been based on the condition that ventilation is available and the cable is protected from the direct rays of sun. If the ambient air temperature is different than that mentioned, the current s should be adjusted according to the table below: RATING FACTOR AMBIENT AIR o TEMPERATURE C Multiply the Rating by a Rating Factor of:

25 RATING FACTORS FOR INSTALLED IN GROUND o GROUND TEMPERATURE C O s for cable laid direct in ground, have been calculated at a ground temperature of 15 C. If the ground temperature is different than the current should be adjusted according to the table below: o GROUND TEMPERATURE C MULTIPLY THE CURRENT RATING DEPTH OF LAYING EFFECTS OF GROUPING OF The current given table have been calculated for one multicore cable, or a set of single core cables forming a circuit. If more than one circuit are laid close to each other, than the current s must be adjusted according to the following group factors. THREE SINGLE CORE FORMING CIRCUITS MULTICORE FORMING CIRCUITS Number of circuits Touching Spacing Trefoil Laid flat 0.15 m 0.3 m 0.5 m 0. m Number of circuits Touching Spacing 0.15 m 0.3 m 0.5 m 0. m 00 / 00 volt 00 / 00 volt / 3 volt 1900 / 3 volt Spacing Spacing Spacing 1

26 DEPTH OF LAYING for cables laid at different depths in ground should be adjusted using the following tablets. 00 / 00 volt cables 1900 / 3 volt cables Depth of laying m up to to Above up to Above or more THERMAL RESISTIVITY OF SOIL The current s given in table have been calculated in consistency with general soil conditions present in the UK. Where data and information of soil along the route of the cable is available, the current can be calculated more precisely using the following table. RATING FACTORS FOR VARIATION IN THERMAL RESISTIVITY OF SOIL Size of Cable O Soil thermal resistivity C m/w Single Core Cables up to 1 From to From 380 to Multi Core Cables Up to From 5 to 1 From to

27 CURRENT RATING AND VOLTAGE DROP 00/00V area of cables Spaced Single core* Approx per ere cables Trefoil touching Twin per ere per ere INSTALLED IN AIR ARMOURED WITH ALUMINIUM CONDUCTOR Three and four cores per ere * Aluminum wire Armoured Distance between cable centres up to and including - Twice overall diameter of cable 0 and above UNARMOURED WITH ALUMINIUM CONDUCTOR area of cables Spaced* Approx per ere Single Core* 3 cables Trefoil touching Approx per ere Laid flat spaced* Approx per ere Twin per ere Three and four cores per ere * Distance between cable centers up to and including - twice overall diameter of cable 0 and above

28 CURRENT RATING AND VOLTAGE DROP 00/00V INSTALLED IN AIR DIRECT IN GROUND ARMOURED WITH ALUMINUM CONDUCTOR area of cables Touching Single core* Approx per ere 3 cables Trefoil touching Twin per ere per ere Three and four cores per ere * Aluminum wire Armoured UNARMOURED WITH ALUMINIUM CONDUCTOR area of Single Core* cables Touching per ere Spaced* Approx per ere 3 cables Trefoil touching Approx per ere Laid flat spaced* Approx per ere Twin per ere Three and four cores per ere * Adjacent cable surfaces separated by 1 cable diameter

29 CURRENT RATING AND VOLTAGE DROP 00/00V RUN IN SINGLE WAY DUCTS ARMOURED WITH ALUMINIUM CONDUCTOR area of cables Ducts Touching * Aluminum wire Armoured Single core* Approx per ere cables Trefoil touching Twin per ere per ere Three and four cores per ere UNARMOURD WITH ALUMINIUM CONDUCTOR area of cables Ducts Touching Approx per ere Single Core* 3 cables Ducts touching trefoil or flat per ere Twin per ere Three and four cores per ere Trefoil Flat

30 SIZE SELECTION GUIDE (BASED ON VOLTAGE DROP OF.5 PER CENT OF 0 V) TWO CORE STRANDED ALUMINUM CONDUCTORS MM 00 CURRENT AMPS ROUTE LENGTH METRES

31 SIZE SELECTION GUIDE (BASED ON VOLTAGE DROP OF.5 PER CENT OF 15 V) THREE AND FOUR STRANDED ALUMINUM CONDUCTORS CURRENT AMPS ROUTE LENGTH METRES 7

32 SHORT CIRCUIT CURRENT Allowable short circuit currents in s of PVC cables 00 ALUMINIUM CONDUCTORS 0 00 PVC INSULATION MAX. TEMP. CONTINOUS o SERVICE C MAX. TEMP. SHORT CIRCUIT o 0 C 00 0 SHORT CIRCUIT CURRENT (KA) ,5 0, 0,3 0, 0,1 0,1 0, 0,3 0, 0,5 1 3 TIME (SEC) 8

33 USEFUL INFORMATION The unit of current is the Ampere ( I ) I = V / R The unit of voltage is the Volt ( V ) V = I R The unit of resistance is the Ohm ( R ) R = V / I The unit of Power is the Watt. ( P ) P = V x I = Volts x Amperes 7 Watts = 1 Horse Power The larger unit of power is the Kilowatt = 1,000 Watts The unit of energy is = 1 Kilowatt hour = 1,000 Watt hours = 1.3 Horse Power hours. 1 Watt =.0013 Horse Power. Kilowatt = 1.3 Horse Power 1 Gallon of Water = pounds = 0.05 cubic foot The pressure of the Atmosphere = 1.7 pounds per square inch Circumference of Circle = diameter X 3.1 Diameter of Circle = circumference X Area of Circle = diameter squared X.785 Diameter of Circle = square root of area X Area of Ellipse = long axis x short axis x.785 Area of Triangle = base x ½ Perpendicular height. Diameter of Circle x.88 = side of an equal square (equal area) Side of Square x 1.83 = diameter of an equal circle (equal area) Surface of a Cylinder = area of both ends + (length x circumference) Surface of a cone = area of base x ½ (slant height x circumference of base) Surface of Sphere = diameter squared x 3.1 Contents of a cylinder = area of one end x length Contents of cone = area of base x 1/3 perpendicular height Contents of Sphere = diameter cubed x.53 Drum capacity in feet = (A + B) A x W x / 1D Where A = depth of flange in inches. B = diameter of barrel in inches. W = width of reel between flanges in inches. D = diameter of material in inches. 9

34 CONVERSION FACTORS TO CONVERT MULTIPLY BY TO CONVERT MULTIPLY BY to in in to 5. to in in to cm to in in to cm.3871 cm to in in to cm 31 m to ft ft to m m to ft.739 ft to m m to ft ft to m KM to Mile 0.1 Mile to KM 093 m to yd 93 yd to m 0.91 m to yd yd to m m to yd yd to m 0.7 kg to lb.0 lb to kg 0.53 kg to cwt cwt to kg.803 kg to tons tons to kg.01 lb to tons tons to lb 0 short tons to tons 99 tons to short tons 1.1 tonnes (metric) to tons tons to tonnes (metric) 0 kg / to lb / in 1.33 lb / in to kg / tons / in to lb / in 0 lb / in to tons / grams / cm to lb / in lb / in to grams / Kg / m to lb / ft 0. lb / ft to kg / m 88 30

35 CONVERSION FACTORS TO CONVERT MULTIPLY BY TO CONVERT MULTIPLY BY kg / m to lb / ft 0.08 lb / ft to kg / m.88 kg / to tons / in 0.0 tons / in to kg / 79 N to lbf 0.8 lbf to N.8 N to kgf 0.0 kgf of N bar to N / m 5 N / m to bar -5 bar to lbf / in 1.5 lbf / in to bar x N / m to lbf / in - x lbf / in to N / m 89.7 kgf / cm to lbf / in 1.3 lbf / in to kgf / cm (litre) to gal (UK) 0.0 gal (UK) to 1 (litre).51 1 (litre) to gal (US) 0. gal (US) to 1 (litre) MULTIPLE AND SUB-MULTIPLE METRIC UNITS Multiple Prefix Symbol Sub-multiple Prefix Symbol 1 tera T -1 deci d 9 giga G - centi c mega M -3 milli m 3 kilo k - micro u hecto h -9 nano n deca da -1 pico p 31

36 TABLE WEIGHTS AND MEASURES AVOIRDUPOIS WEIGHT Dram = grams Ounce ( drams) = 8.39 grams Pound ( ounces) = 0.53 kilograms SUPERFICIAL MEASURE Square in =.513 square centimeters Square foot = square meter Square yard = 3 square meter Quarter (8 pounds) = kilograms Rod = 5.91 meters Hundredweight (11 pounds) =.80 kilograms Ton (0 hundredweight) =.08 kilograms LINEAR MEASURE Millimeter ( 1/00 M.) = inch Centimeter (1/0 M. ) = inch Decimeter (1/ M.) = inches Meter = 39.3 inches = feet Decameter ( M.) = feet Hectometer (0 M.) = ft = 9.3 yards Kilometer (1,000 M.) = yards = mile Myriameter (,000 M.) =.13 miles 1 Inch =.5399 centimeters 1 Foot = meter 3 Feet (1 yard) = meter 1 Fathom ( yards) = 1.88 meters 1 Pole (5 ½ yards) = meters 1 Mile (1,70 yards) = meters or 09 Kilometers 1 Furlong (0 yards) = 0 meters Rood (1, square yards) =.1 ares Acre (.80 square yards) = 0.7 ares Square mile =.588 square kilometers 1 Square Centimeter = 155 square inch 1 Square Meter =.70 square feet 1 Are = square yards 1 Bectare =.711 acres = square mile SOLID MEASURE Cubic inch =.38 cubic centimeters Cubic foot = cubic meter Cubic yard = 0.75 cubic meter 1 Cubic centimeter = 0. cubic inch 1 Cubic meter = 3.53 cubic feet = cubic yards CAPACITY 1 Cubic inch =.38 milliliter 1 Gill = 1198 liter 1 Pint = 58 liter 1 Quart = liters 1 Gallon =.559 liters 1 Milliliter = 0 cubic inch 1 Liter = pints = gallon 3

37 TABLE LOCATION SYMBOLS FOR INSTALLATIONS (from B.S. 8 No. DESCRIPTION SYMBOLE No. DESCRIPTION SYMBOLE 19A 19A 19A 19B1 19B 19B3 19B 19B7 19B9 19B 19B11 19C 19C3 19C 19C 19D1 19D 19E1 19E 19E 19E5 19E 19E8 Control Gear and Distribution Fuseboards Main Switch Switchboard, Distribution Board, or fuseboard Meter Lighting Outlet, etc. Ceiling Outlet Lighting, Filament L Well Outlet Lighting, Filament L Ceiling Outlet Discharge L Lighting Outlet connected to an Emergency System Exit Box with Wiring for Normal and Emergency Systems Ceiling Outlet for Filament Ls with wiring connected to Normal and Emergency Systems Ceiling Outlet with Wiring for Filament and Discharge Ls Ceiling Outlet with wiring for Discharge L connected to Normal System, plus Wiring for Filament L connected to Emergency System Switch Outlets 1 - Way switch - Way switch Intermediate Switch Pull switch Socket outlet (N = - carrying capacity) Switch socket outlet (N = - carrying capacity) Fixed Heating Outlets Tubular Heater Fixed Radiator or Heating Panel Electric Unit Heater Iersion Heater Thermostat Self-contained Electric Water heater 19F1 19F3 19F 19F5 19F7 19G1 19G 19G3 19G 19H1 19H 19H3 19J1 19J 19J3 19J 19L 19M1 19M3 19M 19M Bells, etc. Bell Bush Outlet Bell Buzzer Indicator (N = Number of ways) Bell Transformer Note - May be used for any special L.V. purpose. Telephones Telephone Point public service Telephone Board, public service Telephone Point, internal Telephone Board, internal Clocks Synchronous Clocks Outlet Impulse Clock Outlet Master Clock Fire Alarms Fir Push Automatic Contact Bell connected to Fire Alarm Fire Alarm Indicator (N = Number of ways) Radio Reception Outlets Loudspeaker Outlet Luminous Signal Systems Push Pilot or Corridor L Position Indicator Note - Buzzer may be added if required (N = Number of ways) Rest Position Fixed Apparatus Outlets 19P 19P3 19P5 Outlet for Motor to Fixed Fan Outlet for Motor to Ceiling Fan Cooker Control Unit 33

38 We Also Manufacture 9-N, Model Town, Lahore, Pakistan. UAN: Fax: Web:

YOUR CLEAR CHOICE FOR PREMIUM PACKAGING SOLUTIONS

YOUR CLEAR CHOICE FOR PREMIUM PACKAGING SOLUTIONS YOUR CLEAR CHOICE FOR PREMIUM PACKAGING SOLUTIONS Unit of Length Milli (mm) to Inches MM Decimal of inch Approx. Inch MM Decimal of inch Approx. inch 1 0.0394 3/64 14 0.5512 9/16 2 0.0787 5/64 15 0.5906

More information

TABLES & CONVERSIONS. Linear Conversions. Mass Conversions. Area Conversions. Mass per Area Conversions. Area per Volume Conversions

TABLES & CONVERSIONS. Linear Conversions. Mass Conversions. Area Conversions. Mass per Area Conversions. Area per Volume Conversions TABLES & CONVERSIONS Linear Conversions inches 25.4 millimeters millimeters 0.039 inches feet 0.3 meters meters 3.28 feet yards 0.91 meters meters 1.09 yards miles 1.61 kilometers kilometers 0.62 miles

More information

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY. INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn

More information

PVC POWER CABLES ARMOURED & UNARMOURED PIONEER BY NAME. PIONEER BY DEED.

PVC POWER CABLES ARMOURED & UNARMOURED PIONEER BY NAME. PIONEER BY DEED. PVC POWER CABLES ARMOURED & UNARMOURED OVER PIONEER BY NAME. PIONEER BY DEED. YEARS OF SUCCESS Some s Love To Devour Power You Pay For Electricity flows through the copper strands inside the cables used

More information

I N T R O D U C T I O N

I N T R O D U C T I O N I N T R O D U C T I O N GEMSCAB are being manufactured by the people who have been associated with the industry for over years and understand the requirements their valued customers. The company took up

More information

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION 2007

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION 2007 KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION 2007 Sheet 1 of 5 METRIC CONVERSION Because not all the Contract Documents provided on metric unit contracts

More information

Your Partner in Safe Power Solutions. About RESCAB

Your Partner in Safe Power Solutions. About RESCAB Your Partner in Safe Power Solutions About RESCAB Red Sea Cables Company (RESCAB) was established as a closed joint stock company in 2008 in the Kingdom of Saudi Arabia with a capital of 370 million SAR.

More information

If center column value is F, the C equivalent is to the left. If center column value is C, the F equivalent is to the right.

If center column value is F, the C equivalent is to the left. If center column value is C, the F equivalent is to the right. -40.00-40 -40.0-39.44-39 -38.2-38.89-38 -36.4-38.33-37 -34.6-37.78-36 -32.8-37.22-35 -31.0-36.67-34 -29.2-36.11-33 -27.4-35.56-32 -25.6-35.00-31 -23.8-34.44-30 -22.0-33.89-29 -20.2-33.33-28 -18.4-32.78-27

More information

CONDUCTOR Plain bright annealed copper! alluminium, solid! stranded conductor confirming to IS: 8130: INSULATION INNER SHEATH

CONDUCTOR Plain bright annealed copper! alluminium, solid! stranded conductor confirming to IS: 8130: INSULATION INNER SHEATH c A B L E 5 [B) Techno Flex manufacture high quality heavy duty power cable confirming to IS: 1554 (Part -1) L.T. 1100 volts grade CONSTRUCTION DETAILS:- Power Cable CONDUCTOR Plain bright annealed copper!

More information

Details make the Difference

Details make the Difference 9001:2008 14001:2004 OHSAS 18001:2007 IS 7098 (Part I) Details make the Difference XLPE INSULATED HEAVY DUTY CABLES 650/1100V. Product Range L.V. PVC & XLPE POWER CABLES WITH COPPER AND ALUMINIUM CONDUCTOR

More information

GEMSCAB has been associated with marketing and manufacturing of Electric Cables

GEMSCAB has been associated with marketing and manufacturing of Electric Cables I NTRODUCTION GEMSCAB has been associated with marketing and manufacturing Electric Cables for over a period 4 decades now. Customer satisfaction has been the prime focus GEMSCAB and today it has established

More information

o o blue-brown Fire Performance BS EN BS EN

o o blue-brown Fire Performance BS EN BS EN Standard Power Cables Low age (600/1000 V) Afumex 90 Armoured Power Cable Cable Approvals > Cable approved to BS6724 > Plain annealed copper stranded (Class 2) for ease of handling Insulation > 90 C -linked

More information

CONTENTS. Introduction Customer Service Product Range Specification and Construction...4-6

CONTENTS. Introduction Customer Service Product Range Specification and Construction...4-6 CONTENTS PAGE Introduction... 1 Customer Service...2-3 Product Range... 4 Specification and Construction...4-6 Salient Features of Ducab s Design... 7 Installation and Electrical Data...7-19 XLPE Insulated

More information

Introduction. for over a period 4 decades now. Customer satisfaction has been the prime focus of

Introduction. for over a period 4 decades now. Customer satisfaction has been the prime focus of Introduction GEMSCAB has been associated with marketing and manufacturing Electric s for over a period 4 decades now. Customer satisfaction has been the prime focus GEMSCAB and today it has established

More information

LOW VOLTAGE XLPE INSULATED POWER CABLES

LOW VOLTAGE XLPE INSULATED POWER CABLES Advanced Solutions Through Technology and Innovation LOW VOLTAGE XLPE INSULATED POWER CABLES CONTENTS Page Introduction... 1 Customer Service... 23 Product Range... 4 Specification and Construction...

More information

LOW VOLTAGE c a b l e s

LOW VOLTAGE c a b l e s LOW VOLTAGE c a b l e s MYSORE PLANT SILVASSA PLANT MANUFACTURES A RANGE OF LOW VOLTAGE CABLES AT ITS FACILITIES AT SILVASSA AND MYSORE The Silvassa unit manufactures LV Cables since the year 2000. XLPE/

More information

MATERIAL LIST SPECIFIC TO PART #05724

MATERIAL LIST SPECIFIC TO PART #05724 PD2C HOIST MATERIAL LIST SPECIFIC TO PART #05724 LIT2457-2009 Copyright 2009 PACCAR Winch Division All Rights Reserved This page intentioanlly left blank 2 MODEL NUMBER AND SERIAL NUMBER When information

More information

GENERAL CONVERSION FORMULAE

GENERAL CONVERSION FORMULAE Conversion Tables GENERAL CONVERSION FORMULAE inches millimetres 25.4 millimetres inches 0.0394 inches centimetres 2.54 centimetres inches 0.3937 feet metres 0.3048 metres feet 3.281 yards metres 0.9144

More information

Go to Contents Page BICC. Previous Page Next Page

Go to Contents Page BICC. Previous Page Next Page 1 CONTENTS Page Introduction... 1 Customer Service... Product Range... Specification and Construction... 5 Salient Features of Ducab s Design... 6 Installation and Electrical Data... 617 XLPE Insulated

More information

POLYCAB WIRES PVT LTD TECHNICAL DETAILS. HT XLPE CABLES UPTO 45Kv

POLYCAB WIRES PVT LTD TECHNICAL DETAILS. HT XLPE CABLES UPTO 45Kv POLYCAB WIRES PVT LTD TECHNICAL DETAILS HT XLPE S UPTO 45Kv C O N T E N T S INTRODUCTION ADVANTAGE OF POLYCAB XLPE S SELECTION OF S TECHNICAL DATA Conductor Resistance Current Rating Cable Short Circuit

More information

BS6724 SWA/LSZH Cable IEC /1000V

BS6724 SWA/LSZH Cable IEC /1000V BS6724 SWA/LSZH Cable IEC 60502 600/1000V Applications: Power cable suitable for power networks, where fire emission of smoke and toxic fumes creates a serious potential threat. Suitable for direct burial.

More information

Section 10 Chapter 20

Section 10 Chapter 20 Section 10 Chapter 20 24 Valve, 8.3 Liter Engine Specifications Note: All coding used in the 8.3 Liter and 9 Liter engine manuals are Cuins engine codes. These engine codes have no meaning to New Holland

More information

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets OFFSHORE WIND FEASIBILITY STUDY APPENDICES 10-7 10.3.2 Appendix C.2 Subsea Cable Data Sheets Design data for TFVA 36 kv 3x1x240 mm 2 KQ Metallic Laying up Inner sheath Bedding Armor Diameter of conductor

More information

BS5467. Standard Power Cables. Low Voltage (600/1000 V) Cable Approvals. Conductor. Insulation. Core Identification. Bedding. Outer Sheath.

BS5467. Standard Power Cables. Low Voltage (600/1000 V) Cable Approvals. Conductor. Insulation. Core Identification. Bedding. Outer Sheath. Standard Power Cables Low age (600/1000 V) BS5467 Cable Approvals > Cable approved to BS5467 > Pla annealed copper stranded (Class 2) for ease of handlg Insulation > 90 C -lked XLPE sulation complyg with

More information

Price List "NATIONAL" PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING TO IS:694/2010. Size Twin Two Three Four

Price List NATIONAL PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING TO IS:694/2010. Size Twin Two Three Four Price List HSN Code : 8544 w.e.f. : 01.06.2018 "NATIONAL" PVC FLEXIBLE CABLE WITH COPPER CONDUCTOR SINGLE CORE 1.1 KV CONFORMING TO IS:694/2010. "NATIONAL" PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING

More information

MATERIAL LIST PD7C. PACR WINCH DIVISION P.O. Box 547 Broken Arrow, Oklahoma PHONE: (918) FAX: (918)

MATERIAL LIST PD7C. PACR WINCH DIVISION P.O. Box 547 Broken Arrow, Oklahoma PHONE: (918) FAX: (918) PD7C MATERIAL LIST PACR WINCH DIVISION P.O. Box 57 Broken Arrow, Oklahoma 7013 PHONE: (9) 851-8511 FAX: (9) 259-1575 www.paccarwinch.com LIT-222 R2 12/2008 Printed in U.S.A. Copyright 2008 PACCAR Winch

More information

ORDER LO LI-00664G MAY 1975 (Supersedes L dated 6 APRIL 1973)

ORDER LO LI-00664G MAY 1975 (Supersedes L dated 6 APRIL 1973) LUBRICATION ORDER LO 5-4210-217-12 LI-00664G-12 15 MAY 1975 (Supersedes L05-4210-217-12 dated 6 APRIL 1973) TRUCK, FIRE FIGHTING: POWERED PUMPER; FOAM AND WATER 750 G.P.M. CAP.; CENTRIFUGAL PUMP, POWER

More information

311 Conversion Factors

311 Conversion Factors 311 Conversion Factors Master Converter Some excellent software for converting from nearly any unit of measure to another can be purchased for US$15.00 from Savard Software. Download it from this site

More information

xlpe INSULATED HEAVY DUTY CABLES 650/1100 V. xlpe INSULATED HEAVY DUTY CABLES 650/1100 V. ISO 9001:2000 IS : 69 4

xlpe INSULATED HEAVY DUTY CABLES 650/1100 V. xlpe INSULATED HEAVY DUTY CABLES 650/1100 V. ISO 9001:2000 IS : 69 4 xlpe INSULATED HEAVY DUTY CABLES 650/1100 V. xlpe INSULATED HEAVY DUTY CABLES 650/1100 V. ISO 9001:2000 IS : 69 4 P r o d u c t r a n g e L.T. Pvc & xlpe Power cables with copper / aluminium conductor

More information

CONTROL CABLES CABLES FZE.

CONTROL CABLES CABLES FZE. CONTROL CABLES CABLES FZE www.markcables.com Index Introduction 03 Particulars & Guarantees 05 Copper Conductor, PVC Insulated, PVC Sheathed Cables 08 Copper Conductor, XLPE Insulated, PVC Sheathed Cables

More information

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN UNIT LEVEL MAINTENANCE INFORMATION ON CARTRIDGE, 40MM: DUMMY, M922A1

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN UNIT LEVEL MAINTENANCE INFORMATION ON CARTRIDGE, 40MM: DUMMY, M922A1 TB 9-1300-279-12 DEPARTMENT OF THE ARMY TECHNICAL BULLETIN UNIT LEVEL MAINTENANCE INFORMATION ON CARTRIDGE, 40MM: DUMMY, M922A1 Headquarters, Department of the Army, Washington, DC 10 May 1993 REPORTING

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

HOUSE - WIRING, INDUSTRIAL WIRING.'

HOUSE - WIRING, INDUSTRIAL WIRING.' HOUSE - WIRING, INDUSTRIAL WIRING.' 01 CONTROL PANEL WIRING CABLES AND FLEXIBLE CORDS - 1 1 KV. CONFORMING TO IS: 694 11 SA!3AR" SINGLE CORE PLAIN COPP'ER/ALUMINIUM CONDUCTOR PVC INSULATED UNSHEATEO AND

More information

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4

More information

Caledonian. BS 6346 PVC Insulated, Armored Power and Control Cables. Addison.

Caledonian. BS 6346 PVC Insulated, Armored Power and Control Cables. Addison. Caledonian BS 6346 PVC Insulated, Armored Power and Control Cables www.caledonian-s.co.uk www.caledonian-s.com Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

AN ISO 9001 : 2008 COMPANY

AN ISO 9001 : 2008 COMPANY R AN ISO 9001 : 2008 COMPANY Company Jigar dustries is one the largest manufactures " SIGMA" brand electric wires & cables in dia. The company has a experience manufacturing wires and cables for more than

More information

CENTRIFUGAL FANS. Single Width, Single Inlet WFS & WBS Series WTC TECH CO., LTD. CENTRIFUGAL FANS Single Width, Single Inlet WFS & WBS Series

CENTRIFUGAL FANS. Single Width, Single Inlet WFS & WBS Series WTC TECH CO., LTD. CENTRIFUGAL FANS Single Width, Single Inlet WFS & WBS Series WTC TECH CO., LTD. CENTRIFUGAL FANS Single Width, Single Inlet WFS & WBS Series C. October CENTRIFUGAL FANS Single Width, Single Inlet WFS & WBS Series WTC Centrifugal Fans & AMCA Certification WTC Tech

More information

ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours Candidate Code No. IT 32 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS READ CAREFULLY

More information

XLPE Cable Systems. User s guide. rev. 2

XLPE Cable Systems. User s guide. rev. 2 XLPE Cable Systems User s guide rev. 2 C O N T E N T XLPE Cable Systems Page Page Introduction... 3 XLPE cable systems - design, installation and testing... 4 XLPE cables... Cable accessories... Installation

More information

MATERIAL LIST LB400B RD400B SD400B TD400B. (Covering Part Numbers 05194, 05275, 05276, 05278)

MATERIAL LIST LB400B RD400B SD400B TD400B. (Covering Part Numbers 05194, 05275, 05276, 05278) LB400B RD400B SD400B TD400B MATERIAL LIST (Covering Part Numbers 05194, 05275, 05276, 05278) PACR WINCH DIVISION P.O. BOX 547 BROKEN ARROW, OK U.S.A. 74013 PHONE (918) 251-8511 FAX (918) 259-1575 www.paccarwinch.com

More information

Answer Key. Do Not Distribute

Answer Key. Do Not Distribute 2017 Page 1 of 6 STUDENTS DO NOT OPEN THIS TEST OR BEGIN UNTIL INSTRUCTED TO START 2017 Examination for the National Agricultural Technology and Mechanical Systems Career Development Event Name Print Name

More information

Shearing, bending, and rolling capabilities are available along with fabricating from hand drawn sketches to engineered drawings.

Shearing, bending, and rolling capabilities are available along with fabricating from hand drawn sketches to engineered drawings. Tazgo Machine Inc. is a full service stocking warehouse. Items we stock include carbon, aluminum & stainless steel shapes, angles, beams, flats, hex bar, bar grating, squares, CR rounds in 1018,1045 &

More information

PVC INSULATED WIRING FLEXIBLE AND CONTROL CABLES

PVC INSULATED WIRING FLEXIBLE AND CONTROL CABLES PVC INSULATED WIRING FLEXIBLE AND CONTROL CABLES OVER PIONEER BY NAME. PIONEER BY DEED. YEARS OF SUCCESS Some Cables Love To Devour Power You Pay For Electricity flows through the copper strands inside

More information

THE UK S BENCHMARK FOR TRI-RATED CABLE

THE UK S BENCHMARK FOR TRI-RATED CABLE THE UK S BENCHMARK FOR TRI-RATED CABLE Welcome to Clynder Cables Clynder Cables has over thirty years of experience in the supply of UK manufactured industrial electrical cables to the UK, European and

More information

Unarmoured Single-Core Cables to BS6883

Unarmoured Single-Core Cables to BS6883 Unarmoured Single-Core Cables to BS TAC. EPR. SW 00/00 V 1 Application Unarmoured cable for use where mechanical protection is not required for fixed wiring in ships and in mobile and fixed offshore units

More information

Details make the Difference

Details make the Difference 9001:2008 14001:2004 OHSAS 18001:2007 IS 7098 (Part I) Details make the Difference XLPE INSULATED HEAVY DUTY CABLES 650/1100V. Product Range L.V. PVC & XLPE POWER CABLES WITH COPPER AND ALUMINIUM CONDUCTOR

More information

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed,, PVC Sheathed) 25 47.5 5,292 35 50.5 5,960 50 53.5 6,694 70 58.5 7,816 95

More information

FR-3S Fire Resistant Cables

FR-3S Fire Resistant Cables FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and

More information

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv Medium voltage - Energy RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv Structure and electrical, physical, mechanical requirements: CEI 20-13 IEC 60502 Flame propagation: EN 60332-1-2 Measurement of partial

More information

PD12C MATERIAL LIST PACR WINCH DIVISION

PD12C MATERIAL LIST PACR WINCH DIVISION PD2C MATERIAL LIST Visit our website at www.paccarwinch.com for the most comprehensive collection of winch, hoist and drive information on the internet. Most publications and specification sheets are available

More information

INSTALLATION MANUAL AND PARTS LIST

INSTALLATION MANUAL AND PARTS LIST CAT D8T INSTALLATION MANUAL AND PARTS LIST Installation Parts Kit to Install H140/PA140 Winch on Winch-ready Caterpillar D8T Dozer Installation Parts Kit PACCAR Part number 65248, Caterpillar Part number

More information

Product Range Handbook

Product Range Handbook Product Range Handbook 1 Where to find us Building 144 Culham Number 1 Site Station Road CULHAM Oxon OX14 3DA Sales: +44 (0)1865 409300 Fax: +44 (0)1865 407991 2 INDEX PAGE ROUND BARS 4 SQUARE BAR 5 TEES

More information

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed, PVC Sheathed) 25 39.5 3,292 35 43.0 3,824 50 46.0 4,419 70 50.5 5,264 95 54.5

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V

More information

The Reliable Choice. Field Pocket Guide

The Reliable Choice. Field Pocket Guide The Reliable Choice Field Pocket Guide Allowable Ampacities of STABILOY Brand XHHW-2 and Copper 75 C (167 F) 90 C (194 F) 75 C (167 F) 90 C (194 F) Conductor Size (AWG or kcmil) Types RHW, THHW, THW, THWN,

More information

High Voltage and Extra High Voltage Cables

High Voltage and Extra High Voltage Cables High Voltage and Extra High Voltage Cables GUIDE TO THE SELECTION OF EHV AND HV CABLES EHV and HV cables are specially designed on the basis of the project data. To determine appropriate design of a high

More information

SY Cable. Dungannon Electrical Wholesale Tel: Page 1 of 8

SY Cable. Dungannon Electrical Wholesale Tel: Page 1 of 8 SY Cable Application: Measuring and control cable to connect equipment in production lines / assembly lines and conveyor systems. Can be used both fixed and flexible installations. Techincal Data: 1 Plain

More information

1 Conductor Class 5 flexible annealed plain copper conductor

1 Conductor Class 5 flexible annealed plain copper conductor YY Control Cable Application: YY Control is a flexible mulit-core cable with class 5 flexible annealed plain copper conductors, PVC insulation, and a grey PVC sheath. YY Cable is used in fixed installations

More information

TECHNICAL MANUAL ARMY AMMUNITION DATA SHEETS FOR LAND MINES (FSC 1345)

TECHNICAL MANUAL ARMY AMMUNITION DATA SHEETS FOR LAND MINES (FSC 1345) TECHNICAL MANUAL ARMY AMMUNITION DATA SHEETS FOR LAND MINES (FSC 1345) DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. HEADQUARTERS, DEPARTMENT OF THE ARMY 1 SEPTEMBER

More information

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332 600/1000V XLPE Insulated PVC Sheathed Armoured Power Cables -5 Cores CU/XLPE/PVC 600/1000V Class CU/XLPE/PVC/SWA/PVC 600/1000V Class Application: The cables are mainly used in power stations, mass transit

More information

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2 BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR 1.00.00 GENERAL 1.01.00 Make : Jinan Power Equipment Factory 1.02.00 Type : WX21Z-073LLT 1.03.00 Reference Standard : GB/T7064-2002

More information

INDEX PART A : A TECHNICAL DATA AND GENERAL INFORMATION CONVERSION TABLE WIRE GAUGES CONTINUOUS CURRENT RATING FOR EACH CONDITION OF WIRES & CABLES

INDEX PART A : A TECHNICAL DATA AND GENERAL INFORMATION CONVERSION TABLE WIRE GAUGES CONTINUOUS CURRENT RATING FOR EACH CONDITION OF WIRES & CABLES INDEX PART A : A AND GENERAL INFORMATION CONVERSION TABLE WIRE GAUGES CONTINUOUS CURRENT RATING FOR EACH CONDITION OF WIRES & CABLES TEMPERATURE CORRECTION FACTORS FOR CONDUCTOR RESISTANCE CONDITION OF

More information

S.No. Tender Queries BRPL Reply 1 For 11KV(E) 3Cx300sqmm A2XWY High Ampacity cable conductor details specification not

S.No. Tender Queries BRPL Reply 1 For 11KV(E) 3Cx300sqmm A2XWY High Ampacity cable conductor details specification not S.No. Tender Queries BRPL Reply 1 For 11KV(E) 3Cx300sqmm A2XWY High Ampacity cable conductor details specification not clear.please provide Specification for High ampacity HT Cable with Trapezoidal wire

More information

P High Voltage Catalogue Cables Australia Powering your Project

P High Voltage Catalogue Cables Australia Powering your Project P +61 8 9367 8978 www.cablesaustralia.com.au High Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD HIGH VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated

More information

PLUMBING MATHEMATICS

PLUMBING MATHEMATICS PLUMBING MATHEMATICS A review of basic fundamentals of mathematics is essential to successful applications of plumbing principals. An acceptable reference that may be used during your examination is Mathematics

More information

DURAREEL TRAILING REELING CABLE

DURAREEL TRAILING REELING CABLE Supplementary Technical Information Reeling and trailing material characteristics: A. Power core conductor Flexible strands tinned annealed copper complies with AS/NZS 1802, AS/NZS 2802, AS/NZS 1125, and

More information

POLYCAB WIRES PVT. LTD. PCC LP NO. 2 / Dtd : 1st May Aluminium Armoured

POLYCAB WIRES PVT. LTD. PCC LP NO. 2 / Dtd : 1st May Aluminium Armoured "POLYCAB" Brand Power Cables, Solid Aluminum conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape/extruded Innersheathed for Multicore Cables, Armour (Aluminium wire

More information

POLYCAB WIRES PVT. LTD. PCC LP NO. 6 / Dtd : 6th January 2018

POLYCAB WIRES PVT. LTD. PCC LP NO. 6 / Dtd : 6th January 2018 "POLYCAB" Brand Power Cables, Solid Aluminum conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape/extruded Innersheathed for Multicore Cables, Armour (Aluminium wire

More information

POLYCAB WIRES PVT. LTD. PCC LP NO. 3 / Dtd : 1st August 2018

POLYCAB WIRES PVT. LTD. PCC LP NO. 3 / Dtd : 1st August 2018 "POLYCAB" Brand Power Cables, Solid Aluminum conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape/extruded Innersheathed for Multicore Cables, Armour (Aluminium wire

More information

POCKET GUIDE for TROUBLESHOOTING Gas Products To be used by F.P.I. trained service technicians only.

POCKET GUIDE for TROUBLESHOOTING Gas Products To be used by F.P.I. trained service technicians only. POCKET GUIDE for TROUBLESHOOTING Gas Products To be used by F.P.I. trained service technicians only. 908-489 02/26/99 Table of Contents Tools and Instruments...3 Problem A Pilot not igniting after repeated

More information

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011 ER42 Candidate Code No. For Board Use Only Result Date Result Date Int ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011 Int QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three

More information

Any inquiries, please feel free to contact or Caledonian

Any inquiries, please feel free to contact or Caledonian Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

HSN CODE : 8544 PRICE LIST JANUARY 2018 ALUMINUM UN ARMOURED / ARMOURED W.E.F :

HSN CODE : 8544 PRICE LIST JANUARY 2018 ALUMINUM UN ARMOURED / ARMOURED W.E.F : HSN CODE : 8544 ALUMINUM UN ARMOURED / ARMOURED W.E.F : 09.01.2018 UN ARMOURED ARMOURED Core - 1 Core - 2 Core - 3 Core - 3.5 Core - 4 Core - 1 Core - 2 Core - 3 Core - 3.5 Core - 4 A2XWaY A A A A2XY A2XY

More information

17. There are 2 steps from meters to centimeters There is 1 step from dekameters to meters.

17. There are 2 steps from meters to centimeters There is 1 step from dekameters to meters. 9 Measurement Exercise Set 9-. In the English system the basic units of measurement are the inch, foot, yard and mile. There are inches in a foot, feet in a yard, and 5,80 feet in a mile.. The prefixes

More information

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10 NYY-J Cable Application: A VDE approved, solid conductor, black PVC jacketed, 600/1kV power and control cable. These power cables are designed for energy supply cable ducts, power station, industry and

More information

Calculation of the Cross-sectional Areas of Circuit Live Conductors

Calculation of the Cross-sectional Areas of Circuit Live Conductors Calculation of the Cross-sectional Areas of Circuit Live Conductors MOTOR CIRCUITS SUBJECT TO FREQUENT STOPPING AND STARTING Regulations requires that where a motor is intended for intermittent duty and

More information

PRICE LIST FEBRUARY 2017 ALUMINUM UN ARMOURED / ARMOURED W.E.F :

PRICE LIST FEBRUARY 2017 ALUMINUM UN ARMOURED / ARMOURED W.E.F : ALUMINUM / ARMOURED ARMOURED Core - 1 Core - 2 Core - 3 Core - 3.5 Core - 4 Core - 1 Core - 2 Core - 3 Core - 3.5 Core - 4 A2XWaY A A A A2XY A2XY A2XY A2XY A2XY A2XFaY A2XFY A2XFY A2XFY A2XFY 4 86.00 97.00

More information

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET ER47 Candidate Code No. For Board Use Only Result Date Result Date Int ELECTRICIANS REGULATIONS EXAMINATION 30 June 2012 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Int Time Allowed: Three

More information

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276 APPLICATIONS: The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements

More information

TRUCK, CARGO: M35A1, M35A2, M35A2C, M36A2; TRUCK TANK, FUEL: M49A1C, M49A2C; TRUCK, TANK WATER: M50A1, M50A2, M50A3; TRUCK VAN,

TRUCK, CARGO: M35A1, M35A2, M35A2C, M36A2; TRUCK TANK, FUEL: M49A1C, M49A2C; TRUCK, TANK WATER: M50A1, M50A2, M50A3; TRUCK VAN, TM9-2320-209-10-1-HR HAND RECEIPT COVERING CONTENTS OF COMPONENTS OF END ITEM (COEI), BASIC ISSUE ITEMS (Bll), AND ADDITIONAL AUTHORIZATION LIST (AAL) FOR 2-1/2 TON, 6X6, M44A1 and M44A2 SERIES TRUCKS

More information

Company Profile. Caledonian Medium Voltage Cables

Company Profile. Caledonian Medium Voltage Cables Caledonian Medium Voltage Cables Company Profile Caledonian develops, manufactures and markets a totally integrated product line of Medium Voltage Cables for a diverse variety of technological applications.

More information

Appendix. Conversion Factors LENGTH

Appendix. Conversion Factors LENGTH Appendix Conversion Factors * LENGTH Inches feet 0.083333 angstrom units 2.54 x 10 8 micros 25400 millis 25.4 centis 2.54 s 0.0254 Feet inches 12.0 angstrom units 3.048 x 10 9 micros 304800 millis 304.80

More information

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276- Three Core Cables to VDE 0276 APPLICATIONS The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz. They are

More information

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 38.5 2,603 35 41.5 3,074 50 44.5 3,641 70 48.5 4,536 95 52.0 5,542 120 56.0

More information

Quintas & Quintas Group

Quintas & Quintas Group Electric Conductors Quintas & Quintas Group Index Quintas & Quintas and Solidal 2 Bare Conductors l uminium Conductors for overhead lines 3 l uminium loy Conductors for overhead lines 4 uminium Conductors

More information

PRICE LIST DT. JULY-2014 ALUMINUM UN ARMOURED / ARMOURED W.E.F :

PRICE LIST DT. JULY-2014 ALUMINUM UN ARMOURED / ARMOURED W.E.F : ALUMINUM / ARMOURED W.E.F : 23-07-2014 ARMOURED Core - 1 Core - 2 Core - 3 Core - 3.5 Core - 4 Core - 1 Core - 2 Core - 3 Core - 3.5 Core - 4 A2XWaY A A A A2XY A2XY A2XY A2XY A2XY A2XFaY A2XFY A2XFY A2XFY

More information

PVC INSULATED HEAVY DUTY CABLES

PVC INSULATED HEAVY DUTY CABLES PVC INSULATED HEAVY DUTY CABLES 1100 V. 9001:2008 14001:2004 OHSAS 18001:2007 Details make the Difference IS 1554 (Part I) Product Range L.V. PVC & XLPE POWER CABLES WITH COPPER AND ALUMINIUM CONDUCTOR

More information

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET

ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET ER54 Candidate Code No. For Board Use Only Result Date Result Date Int ELECTRICIANS REGULATIONS EXAMINATION 23 November 2013 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS READ CAREFULLY

More information

CONTENTS. Introduction Customer Service Specification...5. Construction...6. Application...6. Technical Data

CONTENTS. Introduction Customer Service Specification...5. Construction...6. Application...6. Technical Data Content Page CONTENTS Page Introduction... 2 Customer Service... 3-4 Specification...5 Construction...6 Application...6 Technical Data...7-14 1.1 Unarmoured Cables with Overall Screened (TYPE 1)...7 1.2

More information

0.6/1kV Al-Cu XLPE Insulated PVC Sheathed Power Cable

0.6/1kV Al-Cu XLPE Insulated PVC Sheathed Power Cable 0.6/1kV Al-Cu XLPE Insulated PVC ed Power Cable SPECIFICATIONS AND STANDARDS 1.IEC;VDE ;ICEA;AS/NZS; BS; JIS. 2.Rated Voltage: 0.6/1kV 3. Number of cores : One core, two cores, three cores, 3+1 cores,

More information

Volume 2 Charts, Formulas, and Other Useful Information

Volume 2 Charts, Formulas, and Other Useful Information Volume 2 Charts, Formulas, and Other Useful Information Aluminum Conductor Conductor Terminations 61 Compact Aluminum (Conduit Fill Tables) 68-79 Ampacity Dwelling Services 48 1-phase Loads on a 3-phase

More information

LSZH Fire Resistant Cables

LSZH Fire Resistant Cables 300/500V Single-Core ~ 4-Core Mica Tape Fire Barrier, XLPE Insulated, LSZH Sheathed, Fire Resistant Cable CU/MICA/XLPE/LSZH of the electrical circuit is critical in maintaining power supply. Applications

More information

3. Fire Resistant Cables

3. Fire Resistant Cables Fire Resistant Cables The -to-fire is the term used to describe how long a cable continues to operate in a fire. This may be of primary concern, for instance, in life safety of fire fighting installations.

More information

HEADQUARTERS, DEPARTMENT OF THE ARMY

HEADQUARTERS, DEPARTMENT OF THE ARMY * TM 5-6115-465-10-HR DOD MODEL MEP-005A MEP-104A MEP-114A DOD MODEL MEP-005AWF MEP-005AWE MEP-005ALM MEP-005AWM HAND RECEIPT MANUAL COVERING END ITEM/COMPONENTS OF END ITEM (COEI), BASIC ISSUE ITEMS (BII)

More information

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH

More information

NA2XKR(AL)Y 1 x (16-800) mm² 0.6/1

NA2XKR(AL)Y 1 x (16-800) mm² 0.6/1 NA2XKR(AL)Y 1 x (16-800) mm² 0.6/1 NA2XKR(AL)Y 1 x (16-800) mm² 0.6/1 kv Al / XLPE / LS / PVC / AWA / PVC (, XLPE Insuled, ed, Aluminium Wire Armor, ed) Construction Da 16 23.0 1,102 25 23.0 1,104 35 23.0

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable Eland Product Group: A9S APPLICATION Multi-core PVC cable with steel wire armour (SWA). Power and auxiliary control cables for use in power

More information