Capacitive Sensors. Series 80 - PNP

Size: px
Start display at page:

Download "Capacitive Sensors. Series 80 - PNP"

Transcription

1 Ø50 Ø30 Ø43,5 M12x1 Capacitive Sensors Series 80 - PNP Housing: Tri-Clamp Housing material: Stainless steel VA Also suitable for food applications Sensing distance mm adjustable With flange connector M 12 x 1 Certificate: All specifications are subject to change without notice. ( mm mm 4-pin DC Output function Antivalent (NO + NC Art.-No. Connection diagram No. KAS /95-A-PTFE/VA-Y5 Art.-No V DC 2 x 250 ma C Degree of protection IEC IP 67 Connection cable Flange connector M 12 x 1 Housing material VA No Active surface PTFE (FDA 21 CFR Lid , PA / PPO RECHNER Industrie-Elektronik GmbH Gaußstraße 8-10 D Lampertheim Tel. ( Fax ( info@rechner-sensors.de

2 Ø43,5 Ø50 Ø26 Capacitive Sensors Series 80 - PNP Housing Ø 26 mm / Triclamp Useable for an ambient temperature up to +100 C SIP / CIP 121 C Ideal of detection of chemically aggressive media Suitable for foods and parmaceutical applications Certificate: 5 mm 4-wire DC Output Antivalent (NO + NC KAS A-PTFE-Tri-100 C Art.-No. KA 1025 Connection diagram No. 3 KAS A-PTFE-Tri-100 C Art.-No. KA V DC 2 x 250 ma Load current min. - All specifications are subject to change without notice. ( C / CIP 121 C (zero-current Degree of protection IEC IP 67 Connection cable 2 m, PVC, 4 x 0.5 mm² Housing material PTFE (FDA 21 CFR Active surface PTFE (FDA 21 CFR Lid PA RECHNER Industrie-Elektronik GmbH Gaußstraße 8-10 D Lampertheim Tel. ( Fax ( info@rechner-sensors.de

3 Ø50 Ø43,5 Ø26 Capacitive Sensors Series 80 - PNP - StEx - ATEX Housing Ø 26 mm / Triclamp For use in areas with the risk of dust explosion, zone 20 For use in areas with the risk of gas explosion, zone 1 DMT 01 ATEX E 157 IECEx BVS II 2 G Ex mb IIC T4 Gb II 1/2 D Ex ta/tb IIIC T101 C Da/Db Ex mb IIC T4 Gb Ex ta/tb IIIC T101 C Da/Db For Food High chemical resitance 5 mm 4-wire DC Output Antivalent Art.-No. Connection diagram No. KAS A-K-Tri-PTFE-StEx Art.-No. KA V DC 2 x 150 ma All specifications are subject to change without notice. ( C Degree of protection IEC IP 67* Connection cable 2 m, PVC, 4 x 0.5 mm² Housing material PTFE (FDA 21 CFR Active surface PTFE (FDA 21 CFR Lid PC (FDA 21 CFR Accessories * With sealed potentiometer screw , , , is not delivered with the probe RECHNER Industrie-Elektronik GmbH Gaußstraße 8-10 D Lampertheim Tel. ( Fax ( info@rechner-sensors.de

4 Ø50 Ø25,5 Ø46,5 M 12 x1 Capacitive Sensors S26 Series 80 - PNP Type of construction 2 x Triclamp DN 25 Useable for an ambient temperature up to +100 C With flange connector M 12 x 1 HP High Performance Quattro E CProtect ^M ^ME C PTFE EC 1935/2004 conform For Food High chemical resistance CIP SIP 120 C 248 F High Temperature Level sensor, in contact with the product ,5 110 Medium dependent adjustable 4-pin DC Output function Antivalent KAS-80-26/-A-TRI-PTFE-100C-Y5-1-E-HP Art.-No. KA V DC Operating current (I e 2 x ma C / CIP 121 C (zero-current Degree of protection IEC IP 67* Connection Flange connector M 12 x 1 Housing material PTFE (FDA 21 CFR Active surface PTFE (FDA 21 CFR Lid Accessories (not delivered with the sensor: Stainless steel welding nipple DN 25 # , Sealing gasket # , Triclamp mounting clamp # , sealing cap # and matching connectors please see our selection of accessories. * With sealed potentiometer screw PA Capacitive Sensors S26 with hemispherical active surface for level control of products with a dielectric constant ε r as of 1,1. Products can be: Bulk material, like plastic granules, powder, cereals, etc. Liquids, like water, juice, wine, oil, chemicals or pharmaceutical solutions and much more. Pastes in the food processing industry, liquid glue, resins or glue, etc. All specifications are subject to change without notice. (02/ RECHNER Industrie-Elektronik GmbH Gaußstraße 8-10 D Lampertheim Tel Fax info@rechner-sensors.de

5 Capacitive Sensors Series 80 - PNP Housing Ø = 26 mm / 1 / 40 mm Housing material PTFE Useable for an ambient temperature up to +100 C SIP / CIP 121 C With fl ange connector M 12 x 1 Certificate: All specifi cations are subject to change without notice. ( Operating distance Sn Operating distance min./max. adjustable Output Art.-No. Connection diagram No.. Non-fl ush mountable 5 mm 4-pin DC Antivalent (NO + NC KAS A-PTFE-Tri-100 C-Y5 Art.-No. KA V DC 2 x 250 ma Load current min. - < 2.0 V Permitted residual ripple max. 10% C / CIP 121 C (zero-current Green/yellow Degree of protection IEC IP 67 Connection Flange connector M 12 x 1 Housing material PTFE (FDA 21 CFR Active surface PTFE (FDA 21 CFR Lid PA RECHNER Industrie-Elektronik GmbH Gaußstraße 8-10 D Lampertheim Tel. ( Fax ( info@rechner-sensors.de

6 Capacitive Sensors Series 90 - AC/DC Housing Ø = 26 mm / 1 / 40 mm Housing material PTFE SIP / CIP 121 C Sensing distance mm adjustable Certificate: All specifications are subject to change without notice. ( Operating distance Sn 5 mm 5 mm Operating distance min./max. adjustable mm mm 2-wire AC/DC 2-wire AC/DC Output Normally open (NO Normally closed (NC Type KAS S-PTFE-Tri KAS Ö-PTFE-Tri Art.-No. KA 0684 KA 0683 Connection diagram No V AC/DC V AC/DC 250 ma 250 ma Load current min. 5 ma 5 ma < 6.0 V < 6.0 V Permitted residual ripple max. - - Typ. 2.5 ma Typ. 2.5 ma 25 Hz C / CIP 121 C (zero-current C / CIP 121 C (zero-current Yellow Yellow Degree of protection IEC IP 67 IP 67 EN Connection cable 2 m, PUR, 2 x 0.75 mm² 2 m, PUR, 2 x 0.75 mm² Housing material PTFE PTFE Active surface PTFE PTFE Lid PA/PPO PA/PPO 1 2 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-10 D Lampertheim Tel. ( Fax ( info@rechner-sensors.de

7 Capacitive Sensors Series 90 - AC/DC Housing Ø = 26 mm / 1 / 40 mm Housing material PTFE SIP / CIP 121 C Sensing distance mm adjustable Certificate: All specifi cations are subject to change without notice. ( Non-fl ush mountable Non-fl ush mountable Operating distance Sn 5 mm 5 mm Operating distance min./max. adjustable mm mm 2-wire AC/DC 2-wire AC/DC Output Normally open (NO Normally closed (NC Type KAS S-PTFE-Tri KAS Ö-PTFE-Tri Art.-No. KA 0684 KA 0683 Connection diagram No V AC/DC V AC/DC 250 ma 250 ma Load current min. 5 ma 5 ma < 6.0 V < 6.0 V Permitted residual ripple max. - - Typ. 2.5 ma Typ. 2.5 ma 25 Hz C / CIP 121 C (zero-current C / CIP 121 C (zero-current Yellow Yellow Degree of protection IEC IP 67 IP 67 EN Connection cable 2 m, PUR, 2 x 0.75 mm² 2 m, PUR, 2 x 0.75 mm² Housing material PTFE (FDA 21 CFR PTFE (FDA 21 CFR Active surface PTFE (FDA 21 CFR PTFE (FDA 21 CFR Lid PA/PPO PA/PPO RECHNER Industrie-Elektronik GmbH Gaußstraße 8-10 D Lampertheim Tel. ( Fax ( info@rechner-sensors.de

8 Ø50 Ø26 Ø43,5 M12x1 Capacitive Sensors Series 80 - PNP - StEx - ATEX Housing Ø 26 mm / Triclamp For use in areas with the risk of dust explosion, zone 20 With flange connector M 12 x 1 DMT 01 ATEX E 157 IECEx BVS II 1/2 D Ex ta/tb IIIC T101 C Da/Db Ex ta/tb IIIC T101 C Da/Db For Food High chemical resitance All specifications are subject to change without notice. ( Output Art.-No. Connection diagram No. For matching connectors please see our selection of accessories. * With sealed potentiometer screw mm 4-wire DC Antivalent KAS A-K-Tri-PTFE-Y5-StEx Art.-No. KA V DC 2 x 150 ma C Degree of protection IEC IP 67* Connection Flange connector M 12 x 1 Housing material PTFE (FDA 21 CFR Active surface PTFE (FDA 21 CFR Lid PC (FDA 21 CFR Accessories (is delivered with the unit Protective clip RECHNER Industrie-Elektronik GmbH Gaußstraße 8-10 D Lampertheim Tel. ( Fax ( info@rechner-sensors.de

9 Ø31 43,3 M 12 x1 Ø50 Capacitive Sensors Series 80 - PNP - StEx - ATEX Housing Tri-Clamp for use in areas with the risk of dust explosion, zone 20 Sensing distance mm adjustable Ideal for use in food applications With flange connector M 12 x 1, 5-pin incl. protective wire pin DMT 01 ATEX E 157 IECEx BVS II 1/2 D Ex ta/tb IIIC T101 C Da/Db Ex ta/tb IIIC T101 C Da/Db Stainless Steel For Food Output function Art.-No. Connection diagram No. 20 mm mm 4-pin DC Antivalent KAS /100-A-PTFE/VA-Y10-StEx Art.-No. KA V DC 2 x 150 ma frequency of operating cycles max C Degree of protection IEC IP 67* Connection flange connector M 12 x 1 Housing material VA No Active surface PTfE (fda 21 CfR Lid PC (fda 21 CfR Accessories (is delivered with the unit For matching connectors please see our selection of accessories. * With sealed potentiometer screw Protective clip All specifications are subject to change without notice. (06/ RECHNER Industrie-Elektronik GmbH Gaußstraße 8-10 D Lampertheim Tel. +49 ( fax +49 ( info@rechner-sensors.de

10 Ø43,5 Ø50 Ø26 Capacitive Sensors Series 80 - PNP Housing Ø 26 mm / Triclamp Useable for an ambient temperature up to +100 C SIP / CIP 121 C Ideal of detection of chemically aggressive media Suitable for foods and parmaceutical applications Certificate: 5 mm 4-wire DC Output Antivalent (NO + NC KAS A-PTFE-Tri-100 C Art.-No. KA 1025 Connection diagram No. 3 KAS A-PTFE-Tri-100 C Art.-No. KA V DC 2 x 250 ma Load current min. - All specifications are subject to change without notice. ( C / CIP 121 C (zero-current Degree of protection IEC IP 67 Connection cable 2 m, PVC, 4 x 0.5 mm² Housing material PTFE (FDA 21 CFR Active surface PTFE (FDA 21 CFR Lid PA RECHNER Industrie-Elektronik GmbH Gaußstraße 8-10 D Lampertheim Tel. ( Fax ( info@rechner-sensors.de

11 Ø50 Ø25,5 Ø43,5 Capacitive Sensors S26 Series 70 - NPN - StEx - ATEX Series 80 - PNP - StEx - ATEX Type of construction Triclamp DN 25 For use in areas with the risk of dust explosion, zone 20 For use in areas with the risk of gas explosion, zone 1 DMT 01 ATEX E 157 IECEx BVS II 2 G Ex mb IIC T4 Gb Ex mb IIC T4 Gb II 1/2 D Ex ta/tb IIIC T101 C Da/Db Ex ta/tb IIIC T101 C Da/Db HP High Performance Quattro E CProtect ^M ^ME C PTFE EC 1935/2004 conform For Food High chemical resistance Level sensor, in contact with the product Output function * With sealed potentiometer screw Medium dependent adjustable 4-wire DC Antivalent KAS A-K-Tri-PTFE-StEx Art.-No. KA 1183 Connection diagram No. 3 KAS A-K-Tri-PTFE-StEx Art.-No. KA V DC Operating current (I e 2 x ma C Degree of protection IEC IP 67* Connection cable 2 m, PVC, 4 x 0.5 mm² Housing material PTFE (FDA 21 CFR Active surface PTFE (FDA 21 CFR Lid PC (FDA 21 CFR Accessories (not delivered with the sensor: Stainless steel welding nipple DN 25 # , Sealing gasket # , Triclamp mounting clamp # please see our selection of accessories. 3 6 Capacitive Sensors S26 with hemispherical active surface for level control of products with a dielectric constant ε r as of 1,1. Products can be: Bulk material, like plastic granules, powder, cereals, etc. Liquids, like water, juice, wine, oil, chemicals or pharmaceutical solutions and much more. Pastes in the food processing industry, liquid glue, resins or glue, etc. All specifications are subject to change without notice. (02/ RECHNER Industrie-Elektronik GmbH Gaußstraße 8-10 D Lampertheim Tel Fax info@rechner-sensors.de

12 Ø50 Ø43,5 Ø25,5 M 12 x1 Capacitive Sensors S26 Series 80 - PNP Type of construction Triclamp DN 25 Easy Teach Push Button Useable for an ambient temperature up to +100 C With flange connector M 12 x 1 HP High Performance Quattro E CProtect ^M ^ME C ET EasyTeach For Food PTFE EC 1935/2004 conform High chemical resistance 100 C 212 F High Temperature CIP SIP All specifications are subject to change without notice. (02/2017 Level sensor, in contact with the product Medium dependent adjustable 4-pin DC Output function Antivalent KAS-80-26/-A-TRI-PTFE-100C-Y5-ET-HP Art.-No. KA V DC Operating current (I e 2 x ma Max. 15 Hz C / CIP 121 C (zero-current Degree of protection IEC IP 67* Connection Flange connector M 12 x 1 Housing material PTFE (FDA 21 CFR Active surface PTFE (FDA 21 CFR Lid Accessories (not delivered with the sensor: Stainless steel welding nipple DN 25 # , Sealing gasket # , Triclamp mounting clamp # and matching connectors please see our selection of accessories. * Position of the EasyTeach button sealed with sealing screw PA EasyTeachchart: Capacitive Sensors S26 with hemispherical active surface for level control of products with a dielectric constant ε r as of 1,1. Products can be: Bulk material, like plastic granules, powder, cereals, etc. Liquids, like water, juice, wine, oil, chemicals or pharmaceutical solutions and much more. Pastes in the food processing industry, liquid glue, resins or glue, etc. LED / Output function Yellow = A1 Green = A2 Adjustment empty Initializing empty Adjustment full Initializing full Factory reset RECHNER Industrie-Elektronik GmbH Gaußstraße 8-10 D Lampertheim Tel Fax info@rechner-sensors.de Test 57

13 Ø50 Ø43,5 Ø26 Capacitive Sensors Serie 40 - NAMUR EN Housing: Triclamp For use in areas with the risk of dust explosion, zone 20 For use in areas with the risk of gas explosion, zone 0 SIP / CIP 121 C DMT 03 ATEX E 048 IECEx BVS II 1G Ex ia IIC T1-T6 Ga II 1D Ex ia IIIC T101 C Da Ex ia IIC T1-T6 Ga Ex ia IIIC T101 C Da HP High Performance PTFE EC 1935/2004 conform CIP SIP All specifications are subject to change without notice. ( In contact with the product mm 2-wire DC Output NAMUR DIN Type KAS N-K-Tri-PTFE-StEx Art. No. KA 1234 Output current active surface free Output current active surface covered Self-inductance (L Self-capacitance (C 5-15 V DC, U i = 15 V DC < typ 1.5 ma > typ. 3 ma 0.2 mh 250 nf Permitted residual ripple max. 5 % C/ CIP 121 C (zero-current Yellow Degree of protection IEC IP 67 Connection cable 5 m, PUR, 2 x 0.75 mm² Housing material PTFE (FDA 21 CFR Active surface PTFE (FDA 21 CFR Lid PC (FDA 21 CFR Accessory: Stainless steel welding nipple DN 25 # , Sealing gasket # , Triclamp mounting clamp # (not supplied with the sensor RECHNER Industrie-Elektronik GmbH Gaußstraße 8-10 D Lampertheim Tel. ( Fax ( info@rechner-sensors.de

www.rechner-sensors.com CATALOGUE CAPACITIVE SENSORS KAS Registration No.: 1327-01 For all transactions, the newest version of the General Conditions of Sale and Delivery for Products and Services of the

More information

CAPACITIVE SEnSorS 2018

CAPACITIVE SEnSorS 2018 CAPACITIVE SEnSorS 2018 RoHS Compliant Registration No.: 1327-01 For all transactions, the newest version of the General Conditions of Sale and Delivery for Products and Services of the Electrical Industry

More information

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4 Table of contents Page Specifications 2 Applications 4 ------------------------------------------------------------------------------------------------------------ CN 4020 5 Short extension length ------------------------------------------------------------------------------------------------------------

More information

Level limit switch Series RF 3000 Selection list

Level limit switch Series RF 3000 Selection list Table of content Page Overview P2 Applications P4 ------------------------------------------------------------------------------------------------------------- RF 3100 Standard version P6 -------------------------------------------------------------------------------------------------------------

More information

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO from 0... 00 mbar up

More information

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF) Level measurement Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF) TC Fluid Control WIKA data sheet LM LM 3001 30.01 for further approvals see page 3 Applications

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1 > For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX

More information

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Industrial

More information

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves Complete modular designed accessory program More for less - optimal configuration costs Easy maintenance and commissioning

More information

Differential pressure transmitter PASCAL Ci4 Delta P

Differential pressure transmitter PASCAL Ci4 Delta P Differential pressure transmitter PASCAL Ci4 Delta P for general application, Type Series CI4300 Features Differential pressure transmitter with metallic diaphragm High-resolution graphic display with

More information

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0. DMK P Industrial Pressure Transmitter Pressure Ports With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 60 bar up to 0... 400 bar Output signals

More information

Pneumatic control unit for decentralized automation of ELEMENT process valves

Pneumatic control unit for decentralized automation of ELEMENT process valves 890 Pneumatic control unit for decentralized automation of ELEMENT process valves Type 890 can be combined with... Compact design Integrated pilot valve with manual override Integrated control air routing

More information

Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66

Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66 Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS 06.0001 Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application

More information

OPTISWITCH 6500 C Technical Datasheet

OPTISWITCH 6500 C Technical Datasheet OPTISWITCH 6500 C Technical Datasheet Microwave Level Switch for advanced hygienic applications Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Maintenance-free

More information

Level limit switch Series RN 3000 / 6000 Selection list

Level limit switch Series RN 3000 / 6000 Selection list Table of contents Overview 2 Specifications 4 Applications 6 Page -------------------------------------------------------------------------------------------------------- RN..001 8 Short extension length

More information

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm Industrial Pressure Transmitter Pressure Ports With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 60 bar up to 0... 400 bar Output signals

More information

Level limit switch Series RN 3000 / 6000 Selection list. Overview. Specifications. Applications

Level limit switch Series RN 3000 / 6000 Selection list. Overview. Specifications. Applications Table of contents Page Overview Specifications Applications P2 P4 P6 --------------------------------------------------------------------------------------------------------- RN..001 Short extension length

More information

Capanivo Series CN 4000

Capanivo Series CN 4000 Capanivo Series CN 4000 Instruction manual 010516 1 UWT GmbH Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de Scope of this instruction

More information

Level limit switch Series RN 3000 / 6000 Selection list

Level limit switch Series RN 3000 / 6000 Selection list Table of contents Page Overview Specifications Applications P2 P4 P6 -------------------------------------------------------------------------------------------------------- RN..001 Short extension length

More information

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Sheet-Steel Light Fittings Series 6114/1 > As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 40

More information

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter. TEMATEC GmbH Postal address:: Postbox 6 House address Löhestr. 7 5759 Hennef 577 Hennef Fon (+49) 0 4-87 0-0 Fax (+49) 0 4-87 0-0 http: // www.tematec.de e-mail: team@ tematec.de TEMATEC GmbH Data Sheet

More information

Compact pressure switch Model PCS

Compact pressure switch Model PCS Mechatronic pressure measurement Compact pressure switch Model PCS WIKA data sheet PV 33.30 for further approvals see page 4 Process Compact Series Applications Pressure monitoring and control of processes

More information

Differential pressure transmitter PASCAL Ci4 Delta P

Differential pressure transmitter PASCAL Ci4 Delta P Differential pressure transmitter PASCAL Ci4 Delta P for high static working pressure, PN 160, Type series CI4340 Features Simultaneous display of differential pressure and static pressure Long-term stability

More information

OPTISWITCH 6500 C Technical Datasheet

OPTISWITCH 6500 C Technical Datasheet OPTISWITCH 6500 C Technical Datasheet Switch for level detection and dry-run protection Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Maintenance-free KROHNE

More information

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1 www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic

More information

LFT RADAR MICROONDE GUIDATE CONTROLLI DI LIVELLO. LFT level sensor the all-round talent with TDR technology. Dimensional drawing.

LFT RADAR MICROONDE GUIDATE CONTROLLI DI LIVELLO. LFT level sensor the all-round talent with TDR technology. Dimensional drawing. LFT RADAR MICROONDE GUIDATE CONTROLLI DI LIVELLO LFT level sensor the all-round talent with TDR technology Latest technology: TDR sensor with coaxial probe for continual level measurements with analog

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

Level limit switch Series RN 3000 / 6000 Selection list. Overview

Level limit switch Series RN 3000 / 6000 Selection list. Overview Rotonivo Table of contents Page Overview Specifications Applications P2 P4 P6 -------------------------------------------------------------------------------------------------------- RN..00 Short extension

More information

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves 60, 8007 NAMUR / & / > > Port size: G/ and NAMUR interface > > Easily interchangeable solenoid system > > For single and double operated actuators > > Standard manual override with detent > > Maintenance-free

More information

ATEX/IECEx RTD temperature probe

ATEX/IECEx RTD temperature probe Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Mini pressure switch Stainless steel switch enclosure Model PXS

Mini pressure switch Stainless steel switch enclosure Model PXS Mechatronic pressure measurement Mini pressure switch Stainless steel switch enclosure Model PXS WIKA data sheet PV 34.36 Process Mini Series Applications Pressure monitoring and control of processes Safety-critical

More information

Flow sensors. 324 Hans Turck GmbH & Co. KG Tel Fax

Flow sensors. 324 Hans Turck GmbH & Co. KG Tel Fax 324 Hans Turck GmbH & Co. KG Tel. +49 208 49 52-0 Fax +49 208 49 52-264 - Monitoring of limit values and flow patterns are applied in automated manufacturing to detect deviating flow speeds of gases and

More information

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 bar up to 0... 600

More information

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO LMK 87 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... mho up to 0... 00 mho Output signal -wire: 4... 0 ma Special

More information

1.5. 7,250 psi Stainless steel V2A. 7,250 psi Stainless steel V2A. PUR cable type 3 IP 68 Embeddable 600 Hz Table 6 Diagram

1.5. 7,250 psi Stainless steel V2A. 7,250 psi Stainless steel V2A. PUR cable type 3 IP 68 Embeddable 600 Hz Table 6 Diagram 43 1 1 14,9 47 1 9 9 7 Max. operating pressure Sensing face HIGH-PRESSURE-RESISTANT P12 see page 7 see page 14 9 Compatible connectors DW-AD-01-P12-39 DW-AD-03-P12-39 DW-AD-01-P12-2 DW-AD-01-P12-27 DW-AS-01-P12-24

More information

CAPACITIVE LEVEL SENSORS DLS 27

CAPACITIVE LEVEL SENSORS DLS 27 CAPACITIVE LEVEL SENSORS DLS 27 For limit level sensing of liquid, and bulk-solid and powder materials Xi version for usage in explosive areas Direct mounting into various containers, silos, vessels, tanks,

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A

Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A Temperature Resistance thermometer For sanitary applications, exchangeable sensor Model TR22-A WIKA data sheet TE 60.22 for further approvals see page 15 Applications Sanitary applications Food and beverage

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO. Process Pressure Transmitter with HART -communication Ceramic Sensor accuracy according to IEC 60770: 0.1 % FSO Nominal pressure from 0... 160 mbar up to 0... 20 bar Output signals 2-wire:... 20 ma others

More information

Absolute pressure gauge with diaphragm

Absolute pressure gauge with diaphragm Absolute pressure gauge with diaphragm and switch function,type series BF2 Features Absolute pressure gauge with diaphragm and switch function Nominal ranges 0 60 mbar abs to 0 2500 mbar abs With integrated

More information

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

Magnetic switch For bypass level indicators Model BGU for nuclear power plants Level measurement Magnetic switch For bypass level indicators BGU for nuclear power plants KSR data sheet BGU for NPP Applications Magnetic switches for detecting the limits of filling levels in bypass

More information

Magnetic-inductive flow meter for hazardous areas

Magnetic-inductive flow meter for hazardous areas Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials

More information

* * Data sheet MA15F... A/B/C/D. Diaphragm manometer for explosive areas

* * Data sheet MA15F... A/B/C/D. Diaphragm manometer for explosive areas 09005886 DB_EN_MA15_ATEX Rev. ST4-D 03/18 *09005886* Data sheet MA15F... A/B/C/D Diaphragm manometer for explosive areas Gas explosion protection zone 1 and 2, gases and vapours Dust explosion protection

More information

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface 9700 NAMUR / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, NAMUR Interface For single and double acting actuators / or / way function in one valve Easily interchangeable

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

Thermocouple Without thermowell Model TC10-H

Thermocouple Without thermowell Model TC10-H Temperature Thermocouple Without thermowell Model TC10-H WIKA data sheet TE 65.08 for further approvals see page 2 Applications For direct installation into the process Machine building Motors Bearing

More information

Temperature sensor TE2

Temperature sensor TE2 EN/2016-08-09 Design and specifications subject to change without notice Temperature sensor TE2 Temperature sensor type TE2 is a compact temperature sensor, based on RTD technology, which is designed and

More information

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial TEMATEC GmbH Postal address: House address Fon (+49) 0 4-870-0 Postbox 6 Löhestr. 7 Fax (+49) 0 4-870-0 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de TEMATEC GmbH Data Sheet DMP

More information

Resistance thermometer Without thermowell Model TR10-H

Resistance thermometer Without thermowell Model TR10-H Temperature Resistance thermometer Without thermowell Model TR10-H WIKA data sheet TE 60.08 for further approvals see page 2 Applications For direct installation into the process Machine building Motors

More information

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview. Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate

More information

Continuous level sensor NSK

Continuous level sensor NSK SENSORS FOR FOOD AND BIOPHARMA. Product Information NSK-187, -387, -388 FOOD Continuous level sensor NSK Application Continuous level monitoring in metallic vessels up to 2.5 m in height Ideal for highly

More information

Thermocouple For additional thermowell Model TC10-B

Thermocouple For additional thermowell Model TC10-B Temperature Thermocouple For additional thermowell Model TC10-B WIKA data sheet TE 65.02 for further approvals see page 2 Applications Machine building, plant and vessel construction Energy and power plant

More information

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, NAMUR, / 0 0 /-/ Série FEATURES The monostable spool valves have TÜV certified IEC 608 Functional

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

Differential pressure gauge with diaphragm

Differential pressure gauge with diaphragm Differential pressure gauge with diaphragm and switch function,type series BG2 Features Differential pressure gauge with diaphragm and switch function Nominal range -40...0 mbar to -1...24 bar, 0 40 mbar

More information

Terminal Boxes in Stainless Steel SLS**.T

Terminal Boxes in Stainless Steel SLS**.T Features Variant options Stainless steel enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 6 enclosure size options Various terminal and cable gland configurations

More information

Magnetic switch For bypass level indicators Model BGU

Magnetic switch For bypass level indicators Model BGU Level measurement Magnetic switch For bypass level indicators BGU KSR data sheet BGU Applications Magnetic switches for detecting the limits of filling levels in bypass level indicators Chemical and petrochemical

More information

Leading the way in hazardous areas Features EATON

Leading the way in hazardous areas Features EATON .2 Ex-escape sign luminaires EXIT for Zone 1 and Zone 21 / Exit 2 for Zone 2 and Zone 22 Moulded plastic version with LED-technique Leading the way in hazardous areas The EXIT series of explosionprotected

More information

Overview. Specifications. Applications

Overview. Specifications. Applications Vibranivo Level limit switch 1 Series VN 00 / 000 / 000 / 000 Table of content Page Overview P Specifications P Applications P ------------------------------------------------------------------------------------------------------------

More information

Inductive Special Properties

Inductive Special Properties Contents pressue high pressure NAMUR magnetic weld immune temperature extended Special Properties sensors special mechanical and/or electrical properties. Use under extremely harsh conditions Resistant

More information

Level Switch LFFS. Description

Level Switch LFFS. Description R Level Switch LFFS Wetted parts in acidproof, stainless steel and PEEK Compact, food compatible, hygienic design Hygienic connections conform to 3A standards, FDA demands and EHEDG guidelines Precise

More information

Compact Pressure Transmitter DAN-HH

Compact Pressure Transmitter DAN-HH 1 Product Information DAN-HH Compact Pressure Transmitter DAN-HH Application / Specified Usage Authorizations Pressure measurement in pipes and vessels High Temperature applications up to 150 C permanent

More information

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518 3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions

More information

Level measurement Guided microwave Product Information VEGAFLEX ma/hart. Level Switching Pressure

Level measurement Guided microwave Product Information VEGAFLEX ma/hart. Level Switching Pressure Level measurement Guided microwave Product Information VEGAFLEX 62 4 20 ma/hart Level Switching Pressure 2 VEGAFLEX 62 4 20 ma/hart Contents Contents 1 Product description...4 1.1 Configuration... 4 1.2

More information

Level Switch LFFS. Technical Data. Approvals/conformities. Sensor

Level Switch LFFS. Technical Data. Approvals/conformities. Sensor Special Features Wetted parts in acidproof, stainless steel and PEEK Compact, food compatible, hygienic design Hygienic connections conform to 3A standards, FDA demands and EHEDG guidelines Precise switching

More information

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA Mechatronic pressure measurement Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA WIKA data sheet PV 34.38 Applications Pressure monitoring and control of processes

More information

Level Switch LFFS Technical Data

Level Switch LFFS Technical Data 74 03 Special Features Wetted parts in acidproof, stainless steel and PEEK Compact, food compatible, hygienic design Hygienic connections conform to 3A standards, FDA demands and EHEDG guidelines Precise

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 2 Applications For direct installation into the process Machine building

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

Solenoid coils VACF Type codes

Solenoid coils VACF Type codes Solenoid coils VACF Type codes VACF B B2 1A Type VACF Solenoid coil, F series Solenoid coil type A B Width 30 mm, for 8 mm armature tube Width 22 mm, for 8 mm armature tube A1 Connection pattern type A,

More information

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40 Electrical temperature measurement Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40 WIKA data sheet TE 60.06 for further approvals see page 6 Applications Machine building,

More information

2/2- and 3/2-way solenoid valve for aggressive fluids

2/2- and 3/2-way solenoid valve for aggressive fluids 2/2- and 3/2-way solenoid valve for aggressive fluids Type 0121 can be combined with Direct-acting, media-separated valve with diameter of up to DN 8 Maintenance-free pivoted armature technology Vibration-proof,

More information

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of

More information

Sample gas pumps P2.x ATEX

Sample gas pumps P2.x ATEX Gas Analysis Sample gas pumps P2.x ATEX Even in explosive systems in the chemical industry, petrochemistry or biochemistry, gas analysis is key for safe operation. Many of the analysis processes used in

More information

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de

More information

Floodlight Series 6121

Floodlight Series 6121 www.stahl.de Floodlight > For use in gas group IIC (-20 C... +C) gas group IIB + H 2 (-C... +C) > Material Enclosure in seawater resistant cast aluminium Mounting components in stainless steel > Lamp options

More information

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators T 365 EN Type 365 Solenoid Valve Island To control pneumatic actuators Application The Type 365 Solenoid Valve Island is a compact solution for the central control of pneumatic actuators in chemical and

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

Ex Pressostat EXPK 944/947/953. Applications. Features

Ex Pressostat EXPK 944/947/953. Applications. Features Ex Pressostat Swiss based Trafag is a leading international supplier of high quality sensors and monitoring instruments for measurement of pressure and temperature. x Applications x II 2 G / D Features

More information

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc 900/77-80-094-001 158877 For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more compact, space-saving

More information

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Technical brochure Features Ex ll 1G EEx ia llc T4 - T6 in compliance with ATEX 100a Applicable

More information

I Ex-safety switches I

I Ex-safety switches I EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX

More information

OPTISWITCH 4000/5000. Vibration level switches for liquids

OPTISWITCH 4000/5000. Vibration level switches for liquids OPTISWITCH 4000/5000 Technical Datasheet Vibration level switches for liquids Operates up to 250 C / 480 F and 64 bar / 925 psi Pump dry-run detection High reliability due to permanent fault monitoring

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

Flow switches Series AD/VH

Flow switches Series AD/VH Flow switches Series AD/VH Flow switch and indicator for liquids and gases Suitable for clear, opaque or turbid liquids (series AD & VH), and for gases (series AD) Flow switching by means of magnetic coupling,

More information

Level Switch LFFS. distributed by Data sheet

Level Switch LFFS. distributed by   Data sheet Special Features Wetted parts in acidproof, stainless steel and PEEK Compact, food compatible, hygienic design Hygienic connections conform to A standards, FDA demands and EHEDG guidelines Precise switching

More information

Pressure transmitter for industrial applications Type MBS 4510

Pressure transmitter for industrial applications Type MBS 4510 MAKING MODERN LIVING POSSIBLE Data sheet Pressure transmitter for industrial applications Type MBS 4510 The high accuracy flush diaphragm pressure transmitter MBS 4510 is designed for use in non-uniform,

More information

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip Electrical Temperature Measurement Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip WIKA Data Sheet TE 60.22 Applications Temperature measurement at bearings of: T Pumps T Gears T Motors

More information

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series Differential Pressure Gauges Cryo Gauge Model 712.15.160, Cu-alloy Model 732.15.160, Stainless Steel Series Mechanical Pressure Measurement WIKA Data Sheet PM 07.30 Applications Level measurement in closed

More information

Magnetic Inductive Flow

Magnetic Inductive Flow GHM Messtechnik GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49 (0) 9402-9383 - 0 Fax +49 (0) 9402-9383 - 33 www.ghm-messtechnik.de info@ghm-messtechnik.de Magnetic Inductive Flow Characteristics

More information

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600 > 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600

More information

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE

More information

Relative pressure transmitter type 522 for shipbuilding

Relative pressure transmitter type 522 for shipbuilding Relative pressure transmitter type 522 for shipbuilding Pressure range 0... 2.5 600 bar The compact type 522 pressure transmitter for shipbuilding is based upon the Huba Control developed thick film technology

More information

Level Limit Switch liquiphant FTL 365 / FTL 366

Level Limit Switch liquiphant FTL 365 / FTL 366 Technical Information TI 86F/00/en Level Limit Switch liquiphant FTL 65 / FTL 66 Level limit switch Liquiphant II with vibrating probe. For all types of liquid. With explosionproof housing for use in hazardous

More information

Flow measurement FlexFlow PF20H Hygienic flow sensor

Flow measurement FlexFlow PF20H Hygienic flow sensor Product highlights Parallel measurement of flow and temperature Flow measurement independent of the mounting position Large measuring range up to 400 cm/s Measurement at high media temperatures up to 125

More information

I Ex-Safety switches I

I Ex-Safety switches I 3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX

More information