3 Contents Contents 1 Product description Configuration Principle of operation Adjustment Connection to power supply Preparing the connection Wiring plans... 6 Supplement...8 Technical data... 8 Dimensions VEGAFLEX ma/hart 3
4 Product description 1 Product description 1.1 Configuration Scope of delivery The scope of delivery encompasses: the VEGAFLEX 62 level sensor documentation - operating instructions manual - Ex-specific safety instructions (with Ex versions) and, if necessary, further certificates. Components VEGAFLEX consists of the following components: process connection with electrode housing with electronics housing cover with indicating and adjustment module PLICSCOM (option) Housing cover with adjustment module PLICSCOM (option) 1.2 Principle of operation Area of application VEGAFLEX 62 is a level senor with cable or rod electrode for continuous level measurement. It is designed for industrial use in all areas of process technology and is suitable for the measurement of liquids and solids. Physical principle High frequency microwave impulses are guided along a steel cable or rod. The microwave impulses are reflected when they reach the product surface. The impulse running time is processed by the integrated electronics and outputted as distance. Power supply VEGAFLEX has a two-wire electronics 4 20 ma/hart for power supply with V DC. Housing with electronics Process connection 1.3 Adjustment VEGAFLEX can be adjusted with three different media: the indicating and adjustment module PLICSCOM the adjustment software acc. to FDT/DTM standard, e.g. PACTware TM and PC a HART handheld. Fig. 1: Example of a VEGAFLEX 62 in cable version with plastic housing 4 VEGAFLEX ma/hart
5 Connection to power supply 2 Connection to power supply 2.1 Preparing the connection Take note of safety instructions for Ex applications In hazardous areas you should take note of the appropriate regulations and type approval certificates of the sensors and power supply units. The sensors must only be operated on intrinsically safe circuits. The permissible electrical values are stated in the certificate. Anschlusskabel auswählenselect connection cable VEGAFLEX is connected with standard two-wire cable. An outer diameter of 5 9 mm ensures the seal effect of the cable entry. If strong electromagnetic interference is expected, shielded cable is recommended. The screen should be applied on both ends. Select voltage supply VEGAFLEX requires a supply voltage of V DC. Power supply and current signal are led via the same two-wire connection cable. Select connection cable for Ex applications Take note of the corresponding installation regulations for Ex applications. Provide a reliable separation between the external energy source and the mains circuits acc. to DIN VDE 0106 part 101. The VEGA power supply units VEGATRENN 149AEx, VEGASTAB 690, VEGADIS 371 as well as all VEGAMETs meet this requirement. When using one of these instruments, protection class II is ensured for VEGAFLEX 62. Bear in mind the following factors regarding supply voltage: Reduction of the output voltage of the power supply unit under nominal load Influence of additional instruments in the circuit (see load values in Technical data). VEGAFLEX ma/hart 5
6 Connection to power supply 2.2 Wiring plans Single chamber housing Overview Double chamber housing Overview Connection compartment Electronics compartment Plastic Aluminium Stainless steel Fig. 2: Overview of the three materials of the single chamber housing Cable entry (pressure-tight with Exd) Fig. 5: Double chamber housing Top view, electronics and connection compartment Contact springs for adjustment module PLICSCOM Top view, electronics compartment Contact springs for adjustment module PLICSCOM Typ: FX60H mA Display Com. Plug connector for VEGACON- NECT 3 Typ: FX60H mA Display Com. Plug connection for VEGACON- NECT 3 Spring-loaded terminals for 4 20 ma connection Spring-loaded terminals for connection of VEGADIS 61 Ground terminal 1) Fig. 3: Top view of the electronics and connection compartment Wiring plan Internal connection cable to connection compartment Fig. 6: Top view of the electronics compartment of the double chamber housing PC with PACTware TM Display Power supply V DC/ 4 20 ma Plug connection Fig. 4: Wiring plan, single chamber housing VEGADIS 61 1) Connect cable screen here, connect ground terminal on housing exterior to ground as prescribed (low-impedance). The two terminals are galvanically connected. 6 VEGAFLEX ma/hart
7 Connection to power supply Top view, connection compartment Contact springs for adjustment module PLICSCOM Top view, connection compartment Exd 1) Spring-loaded terminals for 4 20 ma connection mA Display Plug connection for VEGACON- NECT mA Com. Ground terminal Spring-loaded terminal for 4 20 ma connection Ground terminal 1) Fig. 7: Connection compartment, double chamber housing Fig. 9: Connection compartment, double chamber housing Exd Wiring plan Exd Wiring plan Power supply V DC/ 4 20 ma 1 2 Plug connection VEGA- CON- NECT 3 Fig. 8: Wiring plan, double chamber housing PC with PACTware TM Power supply V DC/ 4 20 ma 1 2 Screen 2) Fig. 10: Wiring plan, double chamber housing Exd 1) Connect cable screen here, connect ground terminal on housing exterior to ground as prescribed (low-impedance). The two terminals are galvanically connected. 1) The indicating and adjustment module PLICSCOM can be used with Exd only in the electronics compartment. 2) Connect cable screen here, connect ground terminal on housing exterior to ground as prescribed (low-impedance). The two terminals are galvanically connected. VEGAFLEX ma/hart 7
8 Supplement Supplement Technical data General data Materials, wetted parts rod ø 16 mm (316L)/Hastelloy C cable ø 6 mm with gravity weight seal Viton, Kalrez 6375, EPDM and plastic process fittings (316L) and PCTFE; Hastelloy C and PCTFE Materials, non-wetted parts housing plastic PBT, Alu-die casting powder-coated, Stainless steel (316L) inspection window Polycarbonate (Makrolon) ground terminal Stainless steel (316L) Basic weight plastic housing 1580 g Aluminium housing 1990 g Aluminium double chamber housing 2290 g stainless steel housing 2350 g rod (ø 16 mm) approx g/m cable (ø 6 mm) approx. 170 g/m gravity weight (only with cable version) 730 g Process conditions Process pressure bar ( kpa) Process temperature Viton C EPDM C Kalrez C Ambient temperature C C Product temperature Output variable Output signal 4 20 ma/hart Resolution 1,6 µa Fault signal 22 ma; 20.5 ma; 3.6 ma (selectable) Current limitation 22 ma Integration time 1) s, adjustable Rise time 6 sec (ti : 0 s, 0 63 %) 1) The time required by the output signal to reach 63 % of the actual height after a jump of the input variable. 8 VEGAFLEX ma/hart
9 Supplement Ambient conditions Ambient temperature C with PLICSCOM (readability) C Storage and transport temperature C Max. tensile load cable-ø 6 mm 30 KN Lateral load (rod) 30 Nm Tensile load Dependent on the vessel diameter and the level, different tensile forces are acting in solids. In the following charts you will see the values for some typical solids. Metal silo with smooth walls diameter 12 m diameter 9 m diameter 6 m diameter 3 m Cereals 30 Sand Tensile force, 6 mm cable (kn) Tensile force, 6 mm cable (kn) Cable length (m) Cable length (m) Plastic granules Cement Tensile force, 6 mm cable (kn) Tensile force, 6 mm cable (kn) Cable length (m) Cable length (m) VEGAFLEX ma/hart 9
10 Supplement Characteristics Min. span between full and empty adjustment 10 mm Min. dielectric value ε r > 1.7 Sensor length Rod 500 mm 6 m blocked distance top 150 mm blocked distance bottom 0 mm Cable 1 m 60 m blocked distance top 300 mm blocked distance bottom 250 mm 100% 0% % 0% Fig. 11: Measuring ranges of VEGAFLEX VEGAFLEX ma/hart
11 Supplement Accuracy Reference conditions acc. to IEC temperature C relative moisture % air pressure mbar ( kpa) Reference reflector metal plate ø 1 m Installation conditions: flange DN 100 min. distance to obstacles 1 m Temperature drift 0,015 %/10 K relating to the max. meas. range mm Meas. error ,5 0,3 60 m Meas. distance - 10 Reference conditions acc. to IEC Power supply Power supply V DC EEx d ia instrument V DC EEx ia instrument V DC Permissible residual ripple < 100 Hz U ss 1 V 100 Hz 10 khz U ss 10 mv Load see diagram Ω Line resistance + HART resistance Voltage limit non-ex sensor 250 HART load Exd Voltage limit Ex sensor V Output voltage power supply unit Electromechanical data Cable entry and terminals single chamber housing M20 x 1.5 (cable-ø 5 9 mm)/½ NPT double chamber housing M20 x 1.5 (cable-ø 5 9 mm)/½ NPT M16 x 1.5 (cable-ø 4 8 mm) Spring-loaded terminals for wire cross-section up to 2.5 mm² VEGAFLEX ma/hart 11
12 Supplement Electrical protective measures Protection IP 66/IP 67 Overvoltage category III Protection class II Approvals 1) ATEX II 1G, 1/2G, 2G EEx ia IIC T6, ATEX II 1/2G, 2G EEx d ia IIC T6, ATEX II 1/2D IP6X T, ship approvals 1) Deviating data with Ex applications: see separate safety instructions. 12 VEGAFLEX ma/hart
13 Supplement Dimensions VEGAFLEX 62 SW60 G1 1/2 / 1 1/2 NPT , ø 30 ø ø ø 54 VEGAFLEX ma/hart 13
14 Supplement Plastic housing Stainless steel housing Aluminium double chamber housing Aluminium housing ~ 69 ø 77 ~ 69 ø 77 ~ 79 ø 84 M16x1,5 ~ 116 ø 84 M20x1,5 112 (*123) 112 (*123) 112 (*123) 112 (*123) ½ M2 ½ N M20x1,5/ ½ NPT * with display M20x1,5/ ½ NPT Low cover without PLICSCOM High cover with PLICSCOM 23,6 34,5 14 VEGAFLEX ma/hart
15 Supplement VEGAFLEX ma/hart 15
16 VEGA Grieshaber KG Am Hohenstein Schiltach Germany Phone Fax You will have on our homepage under VEGA online Downloads of the following operating instructions manuals menu schematics software certificates approvals and many of other things.
Product information. Capacitive. Level measurement in bulk solids VEGACAL 62 VEGACAL 65 VEGACAL 66 VEGACAL 67. Document ID: 30139
Product information Level measurement in bulk solids VEGACAL 6 VEGACAL 65 VEGACAL 66 VEGACAL 67 Document ID: 09 Contents Contents Description of the measuring principle... Type overview... 5 Housing overview...
More informationPressure measurement. Process pressure VEGABAR 14 VEGABAR 17. Product Information
Pressure measurement Process pressure VEGABAR 4 VEGABAR 7 Product Information Contents Contents Description of the measuring principle........................................................... Type overview..............................................................................
More informationProduct information. Differential pressure. Mechanical and electronic differential pressure measurement
Product information Mechanical and electronic differential pressure measurement VEGADIF 85 VEGABAR 8 VEGABAR 8 VEGABAR 8 VEGABAR 86 VEGABAR 87 Document ID: 65 Contents Contents Measuring principle... Type
More informationOperating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)
Operating Instructions VEGASWING 61, 63 with oscillator SW E60N (EX) Contents Contents Safety information... 2 Note Ex area... 2 1 Product description... 3 2 Function and application... 4 2.1 Principle
More informationOperating instructions
1 2 3 + - 4 ¼ 20 ma 4 12 ¼ 36 V DC E12 - + 5 6 7 8 Level and Pressure Operating instructions VEGABAR 20 DISPLAY VEGADIS 10 0-20 bar p Safety information Safety information The described module must only
More informationXMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.
Process Pressure Transmitter with HART -communication Ceramic Sensor accuracy according to IEC 60770: 0.1 % FSO Nominal pressure from 0... 160 mbar up to 0... 20 bar Output signals 2-wire:... 20 ma others
More informationOperating Instructions OPTISOUND 3010 C 4 20 ma/hart
Operating Instructions OPTISOUND 3010 C 4 20 ma/hart Contents Contents 1 About this document 1.1 Function... 5 1.2 Target group... 5 1.3 Symbolism used... 5 2 For your safety 2.1 Authorised personnel...
More informationOPTISWITCH 4000/5000. Vibration level switches for liquids
OPTISWITCH 4000/5000 Technical Datasheet Vibration level switches for liquids Operates up to 250 C / 480 F and 64 bar / 925 psi Pump dry-run detection High reliability due to permanent fault monitoring
More informationOperating Instructions VEGAPULS 62 standpipe version ma/hart
Operating Instructions VEGAPULS 62 standpipe version 4... 20 ma/hart Contents Contents 1 About this document 1.1 Function... 5 1.2 Target group... 5 1.3 Symbolism used... 5 2 For your safety 2.1 Authorised
More informationOperating Instructions VEGABAR 67
Operating Instructions VEGABAR 67 4... 20 ma/hart Document ID: 36742 Process pressure/ Hydrostatic Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group..............................
More informationSupplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107
Supplementary instructions Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family Document ID: 4107 Contents Contents 1 For your safety... 1.1 Appropriate use...
More informationSupplementary instructions. Centering. for VEGAFLEX series 80. Document ID: 44967
Supplementary instructions Centering for VEGAFLEX series 80 Document ID: 44967 Contents Contents 1 Product description 1.1 Overview... 3 1.2 Centerings... 3 2 Mounting 2.1 General instructions... 10 2.2
More informationOperating Instructions VEGAFLEX 65 Foundation Fieldbus
Operating Instructions VEGAFLEX 65 Foundation Fieldbus Guided Microwave Content Content 1 About this document 1.1 Function............................. 4 1.2 Target group.......................... 4 1.3
More informationPressure measurement. Process pressure/hydrostatic VEGABAR 66 VEGABAR 67. Product Information
Pressure measurement Process pressure/hydrostatic VEGABAR 66 VEGABAR 67 Product Information Content Content 1 Application, function, configuration..............................................................
More informationOperating Instructions VEGABAR 67
Operating Instructions VEGABAR 67 4... 20 ma/hart Document ID: 36742 Hydrostatic Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group..............................
More informationOperating Instructions VEGABAR 65
Operating Instructions VEGABAR 65 4 20 ma/hart Document ID: 27531 p Process pressure/ Hydrostatic Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group..............................
More informationSupplementary instructions. Mounting accessories, pressure measurement technology. Document ID: 43478
Supplementary instructions Mounting accessories, pressure measurement technology Document ID: 78 Contents Contents About this document.... Function.... Target group.... Symbols used... For your safety....
More informationNIVOCONT R VIBRATING ROD LEVEL SWITCHES
For solids NIVOCONT R VIBRATING ROD LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES O U R P R O F E S S NIVOCONT R VIBRATING ROD LEVEL SWITCHES MAIN FEATURES Extension up
More informationDifferential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series
Differential Pressure Gauges Cryo Gauge Model 712.15.160, Cu-alloy Model 732.15.160, Stainless Steel Series Mechanical Pressure Measurement WIKA Data Sheet PM 07.30 Applications Level measurement in closed
More informationElectronic Limit Switch Type
Electronic Limit Switch Type 3738-20 with optional solenoid valve for on/off rotary actuators Application Electronic limit switch for on/off applications to indicate the end position of rotary actuators.
More informationOperating Instructions OPTISWITCH 5200 C, 5250 C with contactless electronic switch
Operating Instructions OPTISWITCH 5200 C, 5250 C with contactless electronic switch Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety
More informationOperating Instructions OPTISWITCH 5100 C, 5150 C with transistor output
Operating Instructions OPTISWITCH 5100 C, 5150 C with transistor output Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety 2.1 Authorised
More informationFlap-Type Flow Meter Prall
Suitable for H 2 O, acids, alkaline solutions and gases Spring-loaded flap Horizontal or vertical direction of flow Largely independent of viscosity Limit contacts, optional Analog output 4 20 ma, optional
More informationOperating Instructions OPTISWITCH 5200 C, 5250 C with transistor output
Operating Instructions OPTISWITCH 5200 C, 5250 C with transistor output Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety 2.1 Authorised
More informationOperating Instructions OPTISWITCH 5200 C, 5250 C with NAMUR output
Operating Instructions OPTISWITCH 5200 C, 5250 C with NAMUR output Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety 2.1 Authorised
More informationOperating Instructions VEGABAR 52. Pressure transmitter with CERTEC measuring cell ma. Document ID: 36716
Operating Instructions Pressure transmitter with CERTEC measuring cell VEGABAR 52 4 20 ma Document ID: 36716 2 Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism
More informationSupplementary instructions Heating for the display and adjustment module PLIC- SCOM
Supplementary instructions Heating for the display and adjustment module PLIC- SCOM Document ID: 31708 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3 Symbols used...
More informationOperating Instructions OPTISWITCH 5100 C, 5150 C with contactless electronic switch
Operating Instructions OPTISWITCH 5100 C, 5150 C with contactless electronic switch Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety
More informationOperating Instructions VEGADIS 61
Operating Instructions VEGADIS 61 Indication and adjustment Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group.............................. 4 1.3
More informationJUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram
Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It
More informationType Electronic Limit Switch
Type 3738-20 Electronic Limit Switch With optional solenoid valve Application Electronic limit switch for on/off applications to indicate the end position. Optionally with integrated solenoid valve. Special
More informationp Additional dimensions see section dimensions.
Hydrostatic pressure sensor Dimensions LHC-M20 with process connection G51 74 LHC-M40 with process connection F76 74 232.5 60 261 G1½ 28 20 Ø22 p Additional dimensions see section dimensions. Function
More informationHydrostatic. Continuous level measurement. Overview Page 186 VEGABAR series 60 Page 188 VEGAWELL 52 Page 192 Accessory Page 194.
Hydrostatic Continuous level measurement Pressure Overview Page 186 VEGABAR series 60 Page 188 VEGAWELL 52 Page 192 Accessory Page 194 185 Hydrostatic Level and pressure measurement Measuring principle
More informationNCR ma/hart four-wire
Quick Setup Guide Radar sensor for continuous level measurement of bulk solids NCR-80 4-20 ma/hart four-wire www.binmaster.com Mounting Mounting preparations, mounting strap The strap is supplied unassembled
More informationSafety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66
Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS 06.0001 Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application
More informationOperating Instructions VEGABAR 51
Operating Instructions VEGABAR 51 4 20 ma Document ID: 36712 Process pressure Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group..............................
More informationOperating Instructions Process pressure transmitter IPT-11 Vers ceramic sensor
Operating Instructions Process pressure transmitter IPT-11 Vers. 4.0 - ceramic sensor 4 20 ma/hart Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group..............................
More informationHydrostatic. Overview 192 VEGABAR series VEGAWELL Accessory 200. Hydrostatic VEGABAR series 60 and VEGAWELL
Hydrostatic Overview 192 VEGABAR series 60 194 VEGAWELL 52 198 Accessory 200 Hydrostatic VEGABAR series 60 and VEGAWELL 191 Hydrostatic Level and pressure measurements Measuring principle The pressure
More informationDifferential pressure transmitter PASCAL Ci4 Delta P
Differential pressure transmitter PASCAL Ci4 Delta P for general application, Type Series CI4300 Features Differential pressure transmitter with metallic diaphragm High-resolution graphic display with
More informationDifferential pressure transmitter PASCAL Ci4 Delta P
Differential pressure transmitter PASCAL Ci4 Delta P for high static working pressure, PN 160, Type series CI4340 Features Simultaneous display of differential pressure and static pressure Long-term stability
More informationElectropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN
Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions
More informationVEGAMET 307 / 308. TIB Technical Information Operating Instructions VEGAMET 308. Signal conditioning instrument. for continuous level measurement
VEGAMET 37 / 38 TIB Technical Information Operating Instructions Signal conditioning instrument for continuous level measurement 2 4 6 8 1 for connection of a capacitive measuring electrode or a pressure
More informationPressure transmitter JUMO dtrans p02
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO
More informationDPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.
Differential Pressure Transmitter for Process Industry with HART Communication accuracy according to IEC 60770: 0.075 % FSO Differential pressure from mbar up to 0 bar Static pressure max. Output signal
More informationOperating Instructions VEGAFLEX 62 Profibus PA
Operating Instructions VEGAFLEX 62 Profibus PA Guided Microwave Content Content 1 About this document 1.1 Function............................. 4 1.2 Target group.......................... 4 1.3 Symbolism
More informationDifferential pressure transmitter PASCAL Ci4 Delta P
Differential pressure transmitter PASCAL Ci4 Delta P for diaphragm seal operation, Type series CI4330 Features Application area General process engineering Chemical and petrochemical industry General process
More informationLevel and pressure instrumentation for wastewater treatment
Level and pressure instrumentation for wastewater treatment Industry Portfolio 4 2 1 5 6 3 11 12 10 25 9 24 7 8 23 22 20 21 19 18 17 16 15 14 13 26 Instrumentation for wastewater treatment Accurate, service-proven
More informationDifferential pressure gauge Model , copper alloy Model , stainless steel version
Mechanical pressure measurement Differential pressure gauge Model 712.15.100, copper alloy Model 732.15.100, stainless steel version WIKA data sheet PM 07.29 Applications for further approvals see page
More informationSeries V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator
Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator ANSI version Application Mixing or diverting valves for heat transfer applications using organic
More informationOperating Instructions VEGACAL 63. Capacitive rod electrode for continuous level measurement ma/hart - two-wire. Document ID: 30027
Operating Instructions Capacitive rod electrode for continuous level measurement VEGACAL 63 4 20 ma/hart - two-wire Document ID: 30027 2 Contents Contents 1 About this document 1.1 Function... 4 1.2 Target
More informationSupplementary instructions Flanges according to DIN - EN - ASME - JIS - GOST Technical data. Document ID: 31088
Supplementary instructions Flanges according to DIN - EN - ASME - JIS - GOST Technical data Document ID: 10 1 Product description 1 Product description 1.1 Specifications The described flanges are threaded
More informationPressure measurement. Process pressure/hydrostatic VEGABAR 51 VEGABAR 52 VEGABAR 53 VEGABAR 54. Product Information
Pressure measurement Process pressure/hydrostatic VEGABAR 51 VEGABAR 52 VEGABAR 5 VEGABAR 54 Product Information Contents Contents 1 Application, function, configuration..............................................................
More informationLevel instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.
Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate
More informationQuick setup guide VEGAPULS 64. Radar sensor for continuous level measurement of liquids ma/hart - two-wire. Document ID: 51462
Quick setup guide Radar sensor for continuous level measurement of liquids VEGAPULS 64 4 20 ma/hart - two-wire Document ID: 51462 Contents Contents 1 For your safety 1.1 Authorised personnel... 3 1.2 Appropriate
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More information97100 NAMUR. Technical data
9700 NAMUR /2-, /2- and / Directional control valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /4, /4 NPT NAMUR Interface For single and double operated actuators
More informationSupplementary instructions. Air cooling - FIBERTRAC 31 with Conduit tube connection. Active air cooling system for radiation-based sensors
Supplementary instructions Air cooling - FIBERTRAC 31 with Conduit tube connection Active air cooling system for radiation-based Document ID: 52847 Contents Contents 1 Product description 1.1 Configuration...
More informationINTERNATIONAL METAL ENGINEERING
INDICATING TEMPERATURE TRANSMITTER WITH HART 8080HT UNIVERSAL SETTINGS WITH HART PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE TECHNOLOGY, 4 TO 20mA ANALOG OUTPUT HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE
More informationDL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
DL 0 Battery Powered for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationLevel Measurement Point level measurement - RF Capacitance switches
Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable
More informationOperating Instructions Process pressure transmitter IPT-1* Vers metalic sensor
Operating Instructions Process pressure transmitter IPT-1* Vers. 3.0 - metalic sensor 4 20 ma/hart Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group..............................
More informationMagnetic-inductive flow meter for hazardous areas
Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials
More informationSATRON VDt Differential Pressure Transmitter
SATRON VDt differential pressure transmitter belongs to V-transmitter family. The series V transmitters have both analog and smart properties. SATRON VDt is used for -,1kPa...-15 MPa ranges. It is a 2-wire
More informationPressure transmitter for elevated media temperatures
Data Sheet 402050 Page 1/7 JUMO dtrans p31 Pressure transmitter for elevated media temperatures General application Pressure transmitters are used for measuring the relative (gauge) and absolute pressures
More informationSeries V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator
Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator ANSI version Application Control valves for heat transfer applications using organic media according
More informationMechatronic pressure measurement. Applications. Special features. Description
Mechatronic pressure measurement Diaphragm pressure gauge with electrical output signal Stainless steel, safety version High overload safety up to 400 bar Models PGT43HP.100 and PGT43HP.160 k Applications
More informationBFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4
Flow Switches Index: B / 923-1838 BFS-10-N / BFS-10-O for monitoring liquids, with or without optical display Features set point continuously adjustable rugged, low hysteresis, any mounting position, high
More informationJUMO dtrans p20 DELTA
Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision
More informationJUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb
sales@jumo.co.uk info@jumo.us Data Sheet 404385 Page 1/6 JUMO dtrans p02 Pressure transmitter II 1/2G Ex ia IIC T6 Ga/Gb General application The pressure transmitter Type JUMO dtrans p02 is used to measure
More informationHigh-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP
High- switch for gas, air, flue gases and combustion products 5.04 Printed in Germany Edition 01.18 Nr. 241 654 1 6 Technical description The switch is an adjustable switch as per EN 1854 (GW 6000 A4 as
More informationOperating Instructions VEGABAR 83. Pressure transmitter with metallic measuring cell ma/hart. Document ID: 45034
Operating Instructions Pressure transmitter with metallic measuring cell VEGABAR 83 4 20 ma/hart Document ID: 45034 2 Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3
More informationSeries 3730 Electropneumatic Positioner Type
Series 3730 Electropneumatic Positioner Type 3730-1 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and
More informationLevel Limit Switch soliphant II FTM 30 (D/S), FTM 31 (D/S), FTM 32 (D/S)
Technical Information TI 9F/00/en Level Limit Switch soliphant II FTM 0 (D/S), FTM (D/S), FTM (D/S) Universal vibration limit switch for fine-grained bulk solids Suitable for dust explosion hazardous areas
More informationOperating Instructions VEGABAR 82. Pressure transmitter with ceramic measuring cell ma/hart. Document ID: 45028
Operating Instructions Pressure transmitter with ceramic measuring cell VEGABAR 82 4 20 ma/hart Document ID: 45028 2 Contents Contents 1 About this document 1.1 Function... 4 1.2 Target group... 4 1.3
More informationSITRANS P measuring instruments for pressure
Overview Application The pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationResistance Thermometers Model TR217, with Spring-Loaded Probe Tip
Electrical Temperature Measurement Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip WIKA Data Sheet TE 60.22 Applications Temperature measurement at bearings of: T Pumps T Gears T Motors
More informationTechnical specification
15. Nov. 2010 Page 1 (5) Metso Rotating Sensor part - Rotating shear force based transmitter for pulp consistency measurement in pulp and paper industry. - Sensing element selection based on pulp type
More informationVortex Flowmeters VFM 3100 F-T VFM 3100 W-T
KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationSeries V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator
Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator DIN version Application Control valves for heat transfer applications using organic media according to
More informationJUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")
Page 1/15 JUMO dtrans p20 Process pressure transmitter Brief description The device with the HART interface combines maximum precision with simple operation. It is used to measure the system pressure of
More informationLevel measurement. Process pressure/hydrostatic VEGABAR 66 VEGABAR 67. Product Information
evel measurement Process pressure/hydrostatic VEGABAR 66 VEGABAR 67 Product Information Content Content 1 Application, function, configuration.................................................... Type overview....................................................................
More informationSoliswitch FTE20. Technical Information. Point level switch for granular solids
Technical Information Point level switch for granular solids Applications The is a paddle switch for granular solids. Its robust and compact design makes the point level switch an ideal sensor for detecting
More informationPressure transmitter PASCAL CV4
Pressure transmitter PASCAL CV4 with threaded connection, Type series CV4100 Features Application area Pharmaceutical industry Food industry Biotechnology General process technology Compact case of stainless
More informationSensor boxes SRBE Key features and product range overview
Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic
More informationInstruction Manual September 2010 SITRANS LVL200S
Instruction Manual September 200 SITRANS LVL200S Contents Contents About this document. Function.................................. 4.2 Target group.............................. 4.3 Symbolism used............................
More informationElectromagnetic Flow Monitor magphant
Technical Information TI 036D/06/en No. 50078457 Electromagnetic Flow Monitor magphant Monitoring and measurement Flow monitoring with selectable limit values (relay output) Flow measurement via 4...20
More informationPortable pressure calibrator, Wally Box III Model CPH7600
Calibration technology Portable pressure calibrator, Wally Box III Model CPH7600 WIKA data sheet CT 17.01 Applications Calibration service companies and service industry Measurement and control laboratories
More informationSeries V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator
Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator DIN version Application Mixing or diverting valves for heat transfer applications using organic media
More informationOperating Instructions VEGASON 61
Operating Instructions VEGASON 61 4 20 ma/hart - four-wire Ultrasonic Contents Contents 1 About this document 1.1 Function.................................. 4 1.2 Target group..............................
More informationValve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator
Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam Nominal size
More informationMetal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam
Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,
More informationOur policy is one of continued research and development. We therefore reserve the right
For single and double operated actuators 3/2-, 5/2- and 5/3 Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4, /4 NPT NAMUR Interface Exhaust
More informationType 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions
More informationSATRON VT Pressure Transmitter
SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kpa...0-100 MPa ranges. It is a 2-wire transmitter with HART standard communication. In pressure measuring
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationKINAX SR 709 Transmitter for Position Feedback
Position transmitter with NAMUR valve fitting Application The position feedback transmitter KINAX SR 709 (Fig. 1 and 2) is used to measure and transmit linear displacement (stroke) on various types of
More informationA Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >
A Higher Level of Performance Data Sheet Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com / Dimensions Centurion Guided Wave Radar Radar Principle of Operation
More informationPressure Transmitter JUMO dtrans p30 Type
Data Sheet 40466 Page 1/6 Pressure Transmitter JUMO dtrans p0 Type 40466 General application Pressure transmitters are used to measure the relative (gauge) and absolute pressures in liquids or gases. The
More information