1 SIEMENS Prüf-Nr./Q-Nr.: Certificate No.: Dienststelle: Department: Ort: PIace: Anlagen: Enclosures: 2267 a I la CE PRM CP SR 1 / Drutschmann Amberg ras: Date: Test Summary Pri,ibescheinigung I Tes-t - Mifræte Erzeugnis I Product: +'no:",3rk1301, ET200S Motor Starter, Standard 3RKlg03 ' rech. Daten: Specification: U = 500V, U" = 400V l"= 12 A Hersteller: SiemenS AG Manufacturer: I n CE Art der Prüfung I Type of test: Type TeSt e ut9r L TQ TL / Mr. prechfl-schöpf Tested by: Labor/ LOVAG registered and DAkkS accredited Laboratory: Testing Laboratory Siemens AG, Amberg Angewandte Prüfbestim m un gen / Iesf spe cif icatio n s ap pl ie d : IEC l: IEC l: Durchgeführte Prüfungen I Tests conducted: Test Sequences l,lll EMG lmmunity and Emission according to IEC Prüfergebnis / Iesf resu/fsr All requirements of the test specification are met. Bemerkungen I Remarks: lssued: lggg This Test Certificate covers ET200S Motor Starters, Standard Size S00, Direct on-line starters, Reversing starters and any accessories. lndex a, dated : Test report were replaced by test summary 2267a. Standard and product range updated. øçø SIEMENS AG I la CE CP PRM SR Mr. Hiereth IIACECPR Industry Sector S. Russwurm (Head) Siemens Aktiengesellschaft: Chairman of the Supervisory Board: Gerhard Cromme; Managing Board: Peter Loescher, Chairman, President and Chief Executive Officer; Wolfgang Dehen, Brigitte Ederer, Joe Kaeser, Barbara Kux, Hermann Requardt, Siegfried Russwurm, PeterY. Solmssen Registered offices: Berlin and Munich, Germany; Commercial reg stries: Berlin Charlottenburg, HRB 12300, Munich, HRB 6684 WEEE-Reg.-No. DE Formular: November 201 0

2 Test summary Manufacturer: Test device: Type: Siemens AG I IA CE Amberg Werner-von-Siemens-Str. 48, Amberg Motor starter 3RK , 3RK Test specification: IEC (2009/09) Test report No.: 09023TEI E BM-B01 Test report No.: 09023TEI04 Test-sequence and sub-clause IEC Test-sequence I and Test (2009/09) Verification of temperature-rise Verification of operation and operating limits Verification of dielectric properties Tested Device 3RK1301-1KBB0-0AA2 tested with 3RK1903-0AA00+ 3RK1903-0AB00+ 3RK1903-0AB10+ 3RK1903-0AE00+ 3RK1903-0AG01+ 3RK1903-0BA00+ 3RK1903-0CD00+ 3RK1903-0CE00+ 6ES7131-4BB01-0AA0+ 6ES7138-4CA01-0AA0+ 6ES7151-7AA20-0AB0+ 6ES7193-4CD20-0AA0 Test-sequence III Performance under short-circuit conditions 3RK1301-1KB00-0AA2 tested with 3RK1903-0AA00+ 3RK1903-0AB00+ 3RK1903-0BA00+ 6ES7131-4BB01-0AA0+ 6ES7138-4CA01-0AA0+ 6ES7151-7AA20-0AB0+ 6ES7193-4CA40-0AA0+ 6ES7193-4CD20-0AA0 For EMC tests see test report no.: from EMC test center Erlangen 09-E BM-B Immunity see EMC test reports Page 1 / 7

3 Test summary Test-sequence and sub-clause Test Tested Device For EMC tests see test report no.: from EMC test center Erlangen 09-E BM-B Emission see EMC test reports The tests were carried out on devices, representative for the whole series, fixed on page 3 and 4. The tests were carried out in the accredited laboratory: Prüflaboratorium der Siemens AG I IA CE Amberg Werner-von-Siemens-Str. 48, Amberg Accredited-No.: D-PL The EMC-Tests were carried out in the accredited laboratory: Siemens AG, EMV-Zentrum Erlangen Günther-Scharowsky-Str. 21, Erlangen Accredited-No.: DAT-P-252/98 Page 2 / 7

4 Nomenclature breakdown Series: 3RK13 3RK A B AA0 I II III IV V VI VII VIII IX I II Basic Type 3RK13, motor starter Type of interface 0 - Profibus-DP III Product type 1 - ET 200S motor starter IV Setting range 0A up to B up to 0.2 0C up to D up to E up to 0.4 0F up to 0.5 0G up to H up to 0.8 0J up to 1 0K up to A up to 1.6 1B up to 2 1C up to 2.5 1D up to 3.2 1E up to 4 1F up to 5 1G up to 6.3 1H up to 8 1J - 7 up to 10 1K - 9 up to 12 V Type of enclosure B - Open type VI Type of function 0 - Electromechanical starter VII VIII IX Version. - Manufacturer s identification Mode of operation 0 - Direct-on-line starter 1 - Reversing starter Model AA0 - Standard model AA1 - Standard model with interface for extension modules AA2 - Standard model with interface for extension modules and electronic inputs are provided. Page 3 / 7

5 Nomenclature breakdown Series: 3RK1903 3RK A A 00 I II III IV V I II Accessories Type 3RK1903 for ET 200S motor starters Accessory groups 0 - Accessories for motor starters 1 - Accessories for safety applications SIGUARD 2 - Accessories for power supply III Type of Accessories A - B - C - Terminal module Power module Special module IV Model Design A to J - Model design V Model 00 - Standard model 01 or 10 - Special model Page 4 / 7

6

7 Technical data Motor starter 3RK Test item particulars...: - kind of equipment...: AC motor starter - number of poles...: 3 - kind of current (a.c. or d.c.)...: ac - interrupting medium...: air - method of operation...: automatic - method of control...: manual / automatic - method of change-over for particular types of starters..: electro magnetic - method of connecting for particular types of starters...: load in delta, load in star -Rated and limiting values, main circuit: - rated operational voltage Ue (V)...: 400 V - rated stator operational voltage Ues (V)...: - - rated rotor operational voltage Uer (V)...: - - rated insulation voltage Ui (V)...: 500 V - rated stator insulation voltage Uis (V)...: - - rated rotor insulation voltage Uir (V)...: - - rated impulse withstand voltage Uimp(kV)...: 6 kv - rated starting voltage of an auto-transformer starter(v).: - - conventional free air thermal current Ith (A)...: Max. 12A - conventional enclosed thermal current Ithe (A)...: - conventional stator thermal current Iths (A)...: - conventional rotor thermal current Ithr (A)...: - rated operational current Ie (A) or rated operational powers...: Max. 12A - rated stator operational current Ies (A) or rated stator - operational powers...: - rated rotor operational current Ier (A)...: - - rated uninterrupted current Iu (A)...: - - rated frequency...: 50 / 60 Hz - rated duties...: - Short-circuit characteristic: - rated prospective short-circuit current "r" (ka)...: 400V / 1 ka - rated conditional short-circuit current Iq (ka)...: 400V / 50 ka Page 6 / 7

8 Technical data Rated and limiting values of relays and releases (overload relays) - types of relay or release...: a) release with shunt coil (shunt trip) b) under voltage and under current opening relay or release c) overload time-delay relay the time-lag of which is: 1) substantially independent of previous load (e.g. time-delay magnetic overload relay) 2) dependent on previous load (e.g. thermal or electronic overload relay) 3) dependent on previous load (e.g. thermal or electronic overload relay) and also sensitive to phase loss d) instantaneous over-current relay or release (e.g jam sensitive, see ) e) other relays or releases (e.g., control relay associated with devices for the thermal protection of the motor f) Stall relay or release - characteristic values a) release with shunt coil, under voltage (under current) opening relay or release.: - rated voltage (current)...: - - rated frequency...: - - operating voltage (current)...: - - operating time...: - - inhibit time...: - b) Overload relay: -designation and current settings...: -rated frequency, when necessary ( for example in case of a current transformer operated overload relay)...: - time-current characteristics (or range of characteristics), when necessary...: - trip class according to classification in table 2, or the value of maximum tripping time, in seconds, under the conditions specified in , table 2, column D, when this time exceeds 40 s....: - number of poles...: 3 Nature of the relay: thermal, magnetic, electronic without thermal memory...: 0,11 0,16A up to 9 12A 50/60Hz available cl. 10 thermal Page 7 / 7

Prüf-Nr./Q-Nr. Certificate No. Dienststelle: Department: Ort: PIace: Anlagen: Enclosures: -Daten: U",", / U = 690V / U *o = 6kV Hersteller:

Prüf-Nr./Q-Nr. Certificate No. Dienststelle: Department: Ort: PIace: Anlagen: Enclosures: -Daten: U,, / U = 690V / U *o = 6kV Hersteller: SIEMENS Prüf-Nr./Q-Nr. Certificate No. Dienststelle: Department: Ort: PIace: Anlagen: Enclosures: 2996 c DF CP R&D VC 2 / Drutschmann Amberg ras: 2016-08-02 Date: Product Description 2996 c Typprtibescheinigung

More information

Dienststelle: Department: Ort: Place: Anlagen: Enclosures: Motor Starter. le (Ac-3) = 2 A at 400 Vac. fe (Ac-3) = '12 A at 400 V""

Dienststelle: Department: Ort: Place: Anlagen: Enclosures: Motor Starter. le (Ac-3) = 2 A at 400 Vac. fe (Ac-3) = '12 A at 400 V Prüf-Nr./Q-Nr.: 2907 uemilcate tuo.: Dienststelle: Department: I la CE CP R&D-VI4 / Drutschmann Ort: Place: Anlagen: Enclosures: Amberg ras: 2012-01-24 Date: Test Summary 2807 a Prtifuescheinigung I Tes-t

More information

Sicherungslose Verbraucherabzweige Leistungsschalter 3VA. fuseless load feeder circuit breaker

Sicherungslose Verbraucherabzweige Leistungsschalter 3VA. fuseless load feeder circuit breaker Nummer: Number: 3343 Bestätigung Confirmation Sicherungsloser Motorabzweig Zuordnungsart 1 2 nach IEC 60947-4-1 bei AC 400 V Fuseless Load Feeder Coordination type 1 2 according IEC 60947-4-1 at AC 400

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1271882 Master Contract: 165071 Project: 2429855 Issued to: Siemens AG I IA CE CP PRM SR Werner-von-Siemens-Strasse 48 Amberg, 92220 Germany Attention: Mr. Michael

More information

Prüf-Nr./Q-Nr.: Ce Tificate No.: Dienststelle: Department: Ort: Amberq Tag: Place: - Date:

Prüf-Nr./Q-Nr.: Ce Tificate No.: Dienststelle: Department: Ort: Amberq Tag: Place: - Date: SIEMENS Prüf-Nr./Q-Nr.: Ce Tificate No.: Dienststelle: Department: 3224 a DF CP R&D V 3 / Drutschmann Ort: Amberq Tag: 2015-02-09 Place: - Date: Anlagen: Test Report= 12094ENV01 Enclosures: 120g4ENV02a

More information

s A Confirmation Bestätigung

s A Confirmation Bestätigung s A0215.02 Confirmation Bestätigung Product identification: Produktbezeichnung Manufacturer: Hersteller Address: Anschrift Fuseless Load Feeders Sicherungslose Verbraucherabzweige 3RV2.4.. + 3RT204.. +

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of CIRCUIT BREAKERS, MOLDED-CASE AND CIRCUIT BREAKER ENCLOSURES

More information

E44653 SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

E44653 SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Auxiliary Devices Type No 3RB2 followed by 0 or 1 followed

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG DF CP R&D V 3 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY This is to certify that representative samples of Combination Motor Controllers (See following pages for additional

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Mechanically Operated and Solid-state

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance (012730_C_000) Issued to: Siemens AG DF CP R&D VC 2 WernervonSiemensStrasse 48 Amberg, 92224 GERMANY The products listed below are eligible to bear the CSA Mark shown Issued by:

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E 1512 E47705 Report Reference E4770519970821 15OCTOBER12 Issued to: SIEMENS AG DF CP R&D V 3 WERNERVONSIEMENSSTRASSE 48 9 AMBERG GERMANY This is to certify that representative samples of MOTOR CONTROLLERS,

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

3TM Vacuum Contactors

3TM Vacuum Contactors Catalog Extract HG 11.23 Edition 2016 Catalog Extract Medium-Voltage Equipment siemens.com/3tm R-HG11-343.psd 2 Siemens HG 11.23 2016 Contents Medium-Voltage Equipment Catalog Extract HG 11.23 2016 Contents

More information

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany File E31519 Project 10CA65262 February 4, 2011 REPORT on MAGNETIC MOTOR CONTROLLERS Siemens AG Amberg, Germany Copyright 2011 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the

More information

Prüffeld der Schaltwerke

Prüffeld der Schaltwerke Report No.: 16-043-MS Sheet: 2 Notes 1. The testing station of the Siemens switchgear factory (Prüffeld der Schaltwerke),, Berlin, has been approved by the DAkkS (German accreditation body) for rendering

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY This is to certify that representative samples of Combination Motor Controllers (See following pages for additional

More information

Motor Starting Solutions Open Type Version, in Kit Form

Motor Starting Solutions Open Type Version, in Kit Form Motor Starting Solutions Open Version, in Kit Form Starters Protected by Manual Motor Starters Direct-On-Line Starters I> Reversing Starters I> MS... Manual motor starter MS... Manual motor starter BEA...

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY This is to certify that representative samples of Auxiliary Devices USL, CNL - Type No. 3RU1146 or 3RU2146 followed

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2049843 (LR 12730-263) Master Contract: 165071 Project: 2460955 Issued to: Siemens AG I IA CE CP PRM SR Werner-von-Siemens-Strasse 48 Amberg, 92220 Germany Attention:

More information

Technical Information

Technical Information Technical Information KT7 Controller Time-Current Characteristic KT7 Manual Motor Starter/Protector 1. Thermal Release Trip Current The adjustable current-dependent delayed bimetal release protects motors

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

General data 5/37. Overview

General data 5/37. Overview General data Overview Benefits High short-circuit breaking capacity in the feeder Optimum usability in motor feeders for the special voltages 440 V, 480 V, 0 V and 690 V Compact design The are available

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial

More information

Reverse power relay and protection assemblies

Reverse power relay and protection assemblies Reverse power relay and protection Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice (SE980053) (SE980054) Features Micro-processor based time directionalcurrent relay/protection

More information

Starting of Induction Motors

Starting of Induction Motors 1- Star Delta Starter The method achieved low starting current by first connecting the stator winding in star configuration, and then after the motor reaches a certain speed, throw switch changes the winding

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work GE Electrical Distribution Gerapid High Speed DC Circuit Breakers On the move imagination at work Gerapid High Speed DC Circuit Breakers To stay up and running today, you need equipment that delivers both

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany File E47705 Project 97ME18400 August 21, 1997 REPORT on MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany Copyright 1997 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above

More information

Prüffeld der Schaltwerke

Prüffeld der Schaltwerke Prüffeld der Schaltwerke Report No.: 16-051-MH Sheet: 2 Notes 1. The testing station of the Siemens switchgear factory (Prüffeld der Schaltwerke),, Berlin, has been approved by the DAkkS (German accreditation

More information

The Contactor. Antonino Daviu, Jose Alfonso Departamento de Ingeniería Eléctrica. Universitat Politècnica de València

The Contactor. Antonino Daviu, Jose Alfonso Departamento de Ingeniería Eléctrica. Universitat Politècnica de València The Contactor Surnames, name Antonino Daviu, Jose Alfonso (joanda@die.upv.es) Department Centre Departamento de Ingeniería Eléctrica Universitat Politècnica de València 1 1 Summary The aim of this paper

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Documents and Addresses

Documents and Addresses Report No.: 05-035-MS/E Sheet: 2 Documents and Addresses Accreditation The Prüffeld der Schaltwerke, Berlin has been approved by the DATech (German accreditation body for technology) according to EN ISO/IEC

More information

SENTRON VL Series Product Specifications

SENTRON VL Series Product Specifications SENTRON VL Series Product Specifications VL 400 Frame 400 s Electronic Releases ETU TRIP RELEASE 315 12-315 3VL4731 - A 3-0AA0 400-400 3VL4740 - A 3-0AA0 3 = 3 poles All VL400 circuit-breakers are shipped

More information

Submittal Data Information

Submittal Data Information Effective: NOVEMBER 3, 2014 JOB CONTRACTOR ITEM NO. Submittal Data Information TDX - Taco Duplex Starter ENGINEER REP. 301-2693 Supersedes: NEW TDX - TACO DUPLEX STARTER 1Ø, 230V, 1/10-15HP 3Ø, 200-460V,

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

Motor Protection Fundamentals. Motor Protection - Agenda

Motor Protection Fundamentals. Motor Protection - Agenda Motor Protection Fundamentals IEEE SF Power and Energy Society May 29, 2015 Ali Kazemi, PE Regional Technical Manager Schweitzer Engineering Laboratories Irvine, CA Copyright SEL 2015 Motor Protection

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V.

CDM1. Standard: IEC Technical data. current A 3P,4P Rated frequency Hz V. voltage Ui V. withstand voltage Uimp V. Function CDM1 molded case circuit breakers can be used to provide the following functions: To distribute electric power and protect circuits and equipment against overload, undervoltage, and short-circuit

More information

37-SDMS-04 SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS

37-SDMS-04 SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Page 1.0 SCOPE 3 2.0 CROSS

More information

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC

More information

Presented to the IAPMO Standards Review Committee on December 9, 2013

Presented to the IAPMO Standards Review Committee on December 9, 2013 Summary of Substantive Changes between the 2010 edition including Updates No. 1 and No. 2 dated September 2010 and August 2011 and the 2013 edition of CSA C22.2 No. 14 Industrial control equipment Presented

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

Data Sheet Manual Motor Starters Ex9SN Series

Data Sheet Manual Motor Starters Ex9SN Series Data Sheet Manual Motor Starters Ex9SN Series www.noarkusa.com NOARK Ex9SN Series Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Industrial contactors CTX-1

Industrial contactors CTX-1 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0 Controlgear Products +27 () 11 97 116 sales@controlgear.co.za Siemens stock items on hand as at Mon, 3/4/218, 14:4 GMT+2 3NA3824-6 LV HRC FUSE LINK S 8A 69AC 25DC 3 3NA3832 LV HRC FUSE LINK GL/GG S 125A

More information

LOW VOLTAGE SWITCHGEAR

LOW VOLTAGE SWITCHGEAR LOW VOLTAGE SWITCHGEAR S-N Motor Control Mitsubishi Electric s S-N Series contactors are perfect for the control of 3 phase power, either for the direct control of a motor, to supply power to a drive or

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS STANDARD METAL CLAD INDOOR VCB TECHNICAL DATA Rated Voltage (Ur) in kv 12 Rated Normal Current (Ir) in Ampere 630/1250 Rated Frequency (fr) in Hz 50 Rated Insulation level (1 min)

More information

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers ABB PTTR SPAIN Zaragoza. The product: Cast coil transformers ABB BA Transformers - 1-5/7/2007 Dry Type Vacuum Cast Coil Transformer INTRODUCTION ABB BA Transformers - 2 - Product Portfolio II Dry Type

More information

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004 Series The WEG Series Manual provide a very compact solution for operation and protection in motor control applications. The NEC requires four functions to be considered a combination motor starter:, ranch,

More information

Bulletin 825 SMM Smart Motor Manager

Bulletin 825 SMM Smart Motor Manager Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

Issued by : Switchgear Contracts Division LARSEN & TOUBRO LIMITED Powai Works, Mumbai October December 1996

Issued by : Switchgear Contracts Division LARSEN & TOUBRO LIMITED Powai Works, Mumbai October December 1996 Issued by : Switchgear Contracts Division LARSEN & TOUBRO LIMITED Powai Works, Mumbai 400 072. October December 1996 Prospect/ Retrospect IS/IEC Specification In the previous three issues of L&T Current

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated AF09... AF3 3-pole contactors 4 to 1.5 kw, AC / DC operated AF09-30-10 AF09... AF3 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors

More information

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation Motor-protectivecircuit-breaker,3p,Ir=2.5-4A Partno. PKZM01-4 Articleno. 278482 CatalogNo. XTPB004BC1 Deliveryprogramme Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton

More information

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60470 Second edition 1999-10 High-voltage alternating current contactors and contactor-based motor-starters Contacteurs pour courants alternatifs haute tension et démarreurs

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1588199 (LR 12730-233) Master Contract: 165071 Project: 1588199 Date Issued: 2004/11/03 Issued to: Siemens AG A&D CD CC TS2 Werner-von-Siemens-Strasse 48 Amberg,

More information

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS 1 Module 2 CONTROL SYSTEM COMPONENTS Lecture - 4 RELAYS Shameer A Koya Introduction Relays are generally used to accept information from some form of sensing device and convert it into proper power level,

More information

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage Information to Order A Rated Current 06 1 60A 100A 2 4 400A 6 600A B Type TN : TN-Type TBN : TBN-Type C Number of Poles 2 : 2P 3 : 3P 4 : 4P OSS - 6 - - P- A B C D D Operating Voltage A1 : AC 110V A2 :

More information

HMI, APRIL, Test Laboratories in Ratingen

HMI, APRIL, Test Laboratories in Ratingen HMI, 24.-28. APRIL, 2017 Test Laboratories in Ratingen Test Laboratories Ratingen Overview Basic Features Flexible Independent Well experienced in testing of medium and low voltage equipment (testing since

More information

WELCOME TO THE WORLD OF COMPLETE AUTOMATION. Innovative MCS Starter Solutions. MCS Starters and the New Mounting System 141A

WELCOME TO THE WORLD OF COMPLETE AUTOMATION. Innovative MCS Starter Solutions. MCS Starters and the New Mounting System 141A WELCOME TO THE WORLD OF COMPLETE AUTOMATION Innovative MCS Starter Solutions MCS Starters and the New Mounting System 141A Welcome to the Wide World of Allen-Bradley Starters Innovative solutions for state

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Thermal Overload Relays

Thermal Overload Relays Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information