1 Page 1 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) RESEARCH DESIGNS & STANDARDS ORGANISATION MINISTRY OF RAILWAY POWER SUPPLY & EMU DIRECTORATE TITLE PARTICULAR SPECIFICATION FOR LHB VARIANT AC 2 TIER EOG TYPE COACHES FITTED WITH RMPUs S.N. Date of amendment Revision No. Page No. Reasons for amendment APPROVED EDPS

2 Page 2 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) SPECIFICATION NO.K2-B-01 PART-II (ELECTRICAL) PARTICULAR SPECIFICATION FOR LHB VARIANT AC 2 TIER EOG COACHES FITTED WITH RMPUs 0.1 FOREWARD 0.2 This particular specification for LHB variant AC 2 Tier EOG type coaches has been prepared for manufacture of these coaches as per the technology received from M/s. LHB, Germany for the same incorporating essentials of Indian Electricity Act and UIC norms. The design and standards for various equipments and sub assemblies have been incorporated as per the specification for the same prepared by RCF based on transfer of technology received by them from M/s LHB. The specification and design for equipments will be standardised by RDSO in future after incorporating the technology offered by M/s. LHB as well as field experience of these equipments. Till such time the RCF specifications for various equipments as mentioned in this particular specification shall be followed. 0.3 This particular specification applies to B.G. L.H.B. variant AC 2 Tier EOG type coaches to RCF layout No. LW The coach shall be suitable to work on End On Generation (EOG) system for supply of power from the power cars provided at either end of the rake. 0.5 The coach is supplied with 750V 3-phase supply, which is defined as high voltage as per definitions given in rule 2 of Indian Electricity Rules. This particular specification incorporates the provision of Indian Electricity Rules 2, 29, 30, 31, 32, 33, 34, 35, 37, 41, 42, 43, 44, 45, 48, 50, 51, 52, 54, 58, 61, 64, 64 (A), 67 & 70 for design and manufacture of coaches to ensure electrical safety of passengers. However, in case Electrical Inspector to the Government of India during his inspection considers the relevance of additional clause of IE rules, the same shall also be complied by the owner seeking sanction. 0.6 The UIC codes 550, 550-1,533 shall generally be applicable for the purpose of electrical design and its standardisation towards public safety and amenities wherever not specified in this specification. 0.7 The provisions of IE rules are statutory in nature and shall be overriding UIC stipulations wherever applicable.

3 Page 3 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) 0.8 The electrical equipments mainly consist of the following:- (i) (ii) (iii) (iv) (v) (vi) (vii) (viii) (ix) (x) (xi) (xii) (xiii) (xiv) Roof Mounted AC Package Unit with micro controller (RMPU). Switch Board Cabinet Electrical light fittings Electrical wiring 60 KVA, 750/415V, 3Ph 50Hz step down transformer Regulated Battery charger Battery Pump equipment with PLC controller and pump box (Water raising apparatus) Pantry appliances ZS couplers (Inter vehicle Coupler) Protection system Mobile and Laptop charging facility Power supply to public address system, anti skid device etc. Fan for electrical cubical and toilets 1.0 SCOPE 1.1 This specification lays down the technical requirements of equipments for electrical lighting, ventilation and air conditioning, water supply, various controls etc. of LHB variant of AC 2 Tier coaches working on EOG system. 2.0 COMFORT CONDITION 2.1 The AC package unit shall have adequate capacity to air condition the coach under the following conditions: Summer conditions Dry bulb Wet bulb % RH Outside (dry summer) 50 deg C 25 deg C - Outside (wet summer) 40 deg C 28 deg C - Inside (dry & wet) deg C % 2.2 The design of RMPU shall be such as to restrict relative humidity to 60% maximum inside the air-conditioned compartment under any circumstances.

4 Page 4 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) 3.0 GENERAL: 3.1 The 750V three phase, 50 Hz AC power supply will be received in the coach through two ZS couplers provided on each end wall of the coach. 3.2 Each coach shall be provided with two Roof Mounted A.C. Package units with a cooling capacity of approx K cal/hr. (Not less than 7.0 TR) for each RMPU. 3.3 The Roof Mounted A.C. Package Unit shall work from 415V, 3Ph, 50Hz, supply obtained from 750/415V, 3Ph, 50Hz, 60KVA transformer provided on underframe of the coach. 3.4 The coach interior lighting will be provided with fluorescent tube lights of 2x18Watt working at 110V AC. The lavatory, doorway, & kitchen will be provided with 1x18 watt fluorescent tube lights working at 110 V AC. 3.5 The coach will have provision of 10 Watt, incandescent emergency lights working on 110V DC battery. Apart from these, all the lavatories, doorway and few passenger compartment lights of 18 W each will work on 110 V DC also during emergency. The emergency lights switch on automatically when power supply from power car fails. 3.6 Each seat will have berth reading light of halogen lamps of 10 Watt each. 3.7 The coach will have two pump equipment with PLC controller for meeting the water supply requirement of the coach by pumping the water from two under frame mounted 685 liters capacity tanks to the over head tanks. 3.8 The coach will have hot case, bottle cooler and refrigerator working at 240V AC for the sub-pantry of the coach. 3.9 All the electrical equipments will be provided with suitable protection arrangements for timely clearance of faulty equipments/circuits The control for anti skid device, light control, emergency lights, reading lights, telephones, night lights, air condition control, berth indication lights, power contactors etc are working on 110 V DC supply.

5 Page 5 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) 3.11 The following equipments shall be provided in the coach. (a) Equipment mounted on the coach under frame:- (i) Transformer 60 KVA, 750/415V, 3Ph, 50Hz - 1 No. (ii) Pump equipment with PLC controller - 2 Nos. (iii) Emergency Battery-110V, 70 Ah - 1No (iv) ZS Couplers - 750V, 3Ph, 4 wire - 2 Sets (b) Equipment mounted on the coach/coach roof. (i) Roof Mounted AC Package Unit (RMPU) - 2 No. (ii) Switch board cabinet - 1No. (iii) Battery charger - 1 No. (iv) Disconnecting and earthing device - 1 No Roof Mounted Package Unit (RMPU) shall be mounted on both ends of the coach between roof and false ceiling as shown in RCF layout No. LW The RMPU shall conform to RCF specification No. EDTS-075, Rev.A, corr.1 type I (with two RMPUs and one microprocessor controller). 4.0 DESIGNS FOR ELECTRICAL EQUIPMENT The design for various electrical equipments will be such that all electric supply-lines and apparatus shall be of sufficient ratings for power, insulation and estimated fault current and of sufficient mechanical strength, for the duty which they may be required to perform under the environmental conditions of installation and shall be constructed and installed to ensure safety of human beings and property. 4.1 Power Supply Arrangement The power system for the coach has been designed to feed the various electrical loads in the system operating at different voltages. There will be following voltage systems for feeding the various electrical loads. i) 750 V, 3 phase, 50 Hz AC ii) 415 V, 3 phase, 50 Hz, AC

6 Page 6 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) iii) 240 V, single phase, AC iv) 110 V, single phase, AC v) 110 V, DC 4.2 The input supply of the coach is at 750V, 3 phase four wire AC supply from the power cars provided at both the ends of the coach through two feeders running in parallel along the length of the coach. 4.3 The 750V, AC and 415 V, AC supplies are categorized as high and medium voltage respectively in terms of definitions given in rule 2 of IE rules and therefore its all relevant clauses pertaining to generation, transmission, conversion & distribution should be applicable. As UIC provisions have also been incorporated in the particular specification, the provision of Indian Electricity Rules will be overriding to the UIC stipulations wherever applicable. 4.4 As per rule 29 of IE rules, all electric supply lines and apparatus shall be of sufficient ratings for power, insulation and estimated fault current and of sufficient mechanical strength, for the duties which they may be required to perform under the environmental conditions of installation, and shall be constructed, installed, protected, worked and maintained in such a manner to ensure safety of human beings, animals and property. 4.5 As per rule 42 of IE rules, all circuits and apparatus shall be so arranged that there shall be no danger of any part thereof becoming accidentally charged to any voltage beyond the limits of voltage for which they are intended. Where AC and DC circuits are installed on the same support they shall be so arranged and protected that they shall not come into contact with each other when live. 4.6 In compliance to IE rule 35, danger notice should be provided at all electrical installations. Instructions (in English or Hindi and local language) for restoration of person suffering from electrical shock in English and Hindi shall be provided in compliance to clause no. 44 of IE rule. 4.7 As per rule 41 of IE rules, the power car, switch board cabinet and junction boxes in which there are any circuits or apparatus (whether intended for operation at different voltages or at the same voltage) shall ensure by means of indication of a permanent nature that the respective circuits are readily distinguishable from one another.

7 Page 7 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) 4.8 The switch board cabinet receiving the supply from two feeders should have indication of a permanent nature for clear distinction of the supply from these feeders. Similarly the supply coming from pre cooling socket also needs to be provided with an identification mark on the cabinet. 4.9 The control circuit as well as feeder contactor provided for receiving the supply from the feeders should have necessary interlocking to prevent simultaneous charging of the coach from two feeders, as per approved scheme for the same As per rule 51 of IE rules, all conductors shall be completely enclosed in mechanically strong metal casing or metallic covering which is electrically and mechanically continuous and adequately protected against mechanical damage unless the said conductors are accessible only to an authorised person or are installed and protected to the satisfaction of the inspectors so as to prevent danger. Non metallic conduits confirming to the relevant Indian Standard Specification may be used for medium voltage installations, subject such conditions as the inspector or officer appointed to assist the inspector may think fit to impose. All metal works, enclosing, supporting or associated with the installation, other than that designed to serve as a conductor shall be connected with an earthing system as per standards in this regard laid down in Indian Standards and also in accordance with rule 61 (4) Every switch board shall have a clear space of not less than one meter in width in front of the switch board. If there are any attachment or bare connection at the back of the switch board, the space behind the switch board shall be either less than 20 cm or more than 75 cm in width measured from the farthest outstanding part of any attachment or conductor. If the space behind the switch board exceeds 75 cm in width there shall be a passageway from either side of the switch board, clear to the height of 1.8 meter As per rule 30 of IE rules, supply lines will be so laid to be protected against mechanical, electrical and chemical damage to insulation and with due precaution to avoid danger arising on such premises from such supply lines, fittings and apparatus Appliances to be installed in safe condition so that no danger can arise out from them As per rule 43 of IE rules, fire buckets filled with clean dry sand and ready for immediate use for extinguishing fire, in addition to fire extinguishers suitable

8 Page 8 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) for dealing with electric fires, shall be conspicuously marked and kept in all generating stations, enclosed sub stations in convenient situations As per rule 44 of IE, instructions in English or Hindi and the local language for restoration of persons suffering from electric shocks shall be affixed in power cars and switch board cabinet of coaches in a conspicuous place. All authorised person employed for operation and maintenance shall be acquainted with and are competent to apply the instructions referred to above. In manned coach with high voltage an artificial respirator shall be provided and kept in good working condition While getting any work of electrical installation, commissioning, modification etc through out side agencies, IE rule 45 should be followed In compliance to the IE rule 54, the incoming supply voltage at coach shall not vary by more than 6 percent on higher side and 9 percent on the lower side As per rule 50 of IE rules, the control of requisite capacity to carry and break the current will be placed after point of commencement of supply as per rule 58 so as to be readily accessible and capable of being easily operated to completely isolate the supply of installation, such equipment being in addition to any equipment installed for controlling individual circuits or apparatus. There should be linked switch with fuses or a circuit breaker for low, medium and high voltage As per rule 50 of IE rules, except incase of composite control gear designed as a unit every distinct circuit protected against excess energy by means of suitable cut out or a circuit breaker of adequate breaking capacity suitably located and so constructed as to prevent danger from overheating, arching and scattering of hot metal when it comes into operation and to permit for ready renewal of fusible metal of the cut out without danger All the insulating material are chosen with special regard to the circumstances of its proposed use and their mechanical strength is sufficient for its purpose and so far as is practicable of such character or so protected as to maintain its insulating property under all working conditions in respect of temperature and moisture As per rule 64 of IE rules, for supplies at high voltage all the conductor or apparatus will be so placed so as to be inaccessible except to an authorised

9 Page 9 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) person and all operations in connection with the said conductors and an authorised person carries out apparatus In compliance to the IE rule 64(A), the protection system should automatically disconnect the supply when rated current of the equipment, cable or supply line is exceeded for a time for which the equipment, cable or supply line is not designed to withstand In compliance to IE rule 31, a suitable cut out should be provided in incoming supply line of the coach in each conductor of every supply line other than earthed or earthed neutral conductor in an accessible position. Such cut out shall be contained within an adequately enclosed fireproof receptacle The coach will connect the input supply from either of the two feeders available on the coach at 750V three-phase supply through disconnecting and earthing device provided in switch board cabinet The 750V 3-phase supply is stepped down to 415V, 3-phase supply with the help of one 60 KVA epoxy cast and encapsulated transformer, which is provided on the under frame of the coach The electrical equipments of Roof Mounted Package Units, exhaust fans & pump equipment are supplied with 415V, 3-phase supply received from 60 KVA transformer Loads of electrical appliances provided in sub pantry such as hot case, bottle cooler, and refrigerator shall be fed with single phase at 240V, 50Hz by using one out of the three phases and neutral connection of 3 phase 415 V AC supply The lights, electric razor socket etc. shall be supplied at 110V, single-phase AC supply received from regulated battery charger The 110 V DC is used for supplying control for Roof Mounted Package Unit, anti-skid device, light control, emergency lights, telephones, night lights, berth reading lights, power contactors etc A DC-DC converter shall be used to obtain 24 V DC for supplying control systems for pump, sanitary and public address system, UIC remote control, return air flap unit & servo motor of air conditioning system etc.

10 Page 10 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) 4.31 The power & control supply arrangement to various electrical loads in the coaches shall generally be similar to originally imported LHB AC coaches. The 415/240V AC network is designed as unearthed IT-4 conductor system as per IEC Roof coach wiring shall be routed in PVC rigid conduit/trenches conduits. Under frame wiring shall be with IP 68 protection and shall be covered with perforated cable trays as a primary safe guard against ballasts hitting The design of electrical accessories, connections, terminations of layout etc. of cables and the sub-assemblies will be in general similar to originally imported LHB coaches The cables used for power and control wiring shall be thin walled Electron beam irradiated flexible elastomeric cables as per RCF specification No. EDTS 132, Rev. A. Cable marker shall be used for cable identification. The cable markers should not come out during service life All the equipment above 250 V shall be earthed at two places and below 250 V at one place. Voltage segregation shall be ensured during wiring The system will have earth fault/earth leakage protection to disconnect the supply automatically, if the earth fault current exceeds the limit of current for keeping the contact potential within reasonable limits General provision of power supply installation in the coach must comply with the following provision of as indicated in UIC 550. a) Even as per requirement of rule 37 of IE, each vehicle shall be fitted with an isolating and earthing switch that allows all equipments connected to the train line to be disconnected on load in one action. The position of the device must be marked as given in Annexure A. b) Suitable rating of the fuses shall be provided to protect against absolute short circuit that is to say when the short circuit current is more than 5 IN. c) The vehicle axle box shall be fitted with electric insulation in order to allow the current from loads, connected to the rail line to flow to the rail without damage to the bearing.

11 Page 11 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) d) In order to short circuit the insulation of the axle box following should be fitted on each bogie at least - One axle box with an earth contact through which the return current can flow and - On the each of the other boxes not fitted with an earthing contact a shunt of protective resistance of 100 m ohm. - The basic diagram is enclosed as Annexure B e) All the distribution and control panel of the coach and the equipment cases under the body, in which the voltage is greater than 150V AC or 110V DC shall be marked by a danger sign of skill and bones as per rule 35 of IE rules of a design as per relevant ISS: 2551 on every motor, generator, transformer and other electrical plants and equipments together with apparatus used for controlling or regulating the same, provided that where it is not possible to affix such notices on any generator, motor, transformer or other apparatus they shall be affixed as near as possible thereto (or the word danger and the voltage of the apparatus concerned shall be painted on it. Where the generator, motor, transformer or other apparatus is within an enclosure, one notice on the said enclosure shall be sufficient for the purpose of this rule. f) Sockets that are accessible to passengers and are live during operation can be fitted with shutters (child protection) as specified in IEC: 884. g) Each coach shall be provided with atleast one spare fuse for high voltage circuits and two fuses for low voltage circuit, for each size used. h) The spare fuses shall when possible be located in the cupboard equipment, accessible by means of square socket key. If they are placed elsewhere, their location shall be specified on a notice displaced on the cupboard. i) The rakes containing the spare fuses shall be marked with the nominal rating of the fuses All material used in wiring, switch board, connection, clamps/cleats, assemblies/sub-assemblies will have fire retardant property as per UL AIR CONDITIONING AND AIR CIRCULATING SYSTEM 5.1 The coach will be provided with two Roof Mounted Package Unit as per RCF s specification No. EDTS-075 Rev.A, cor. 1 type I (two RMPUs with one microprocessor controller).

12 Page 12 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) 5.2 Air conditioning system shall be adjusted for intake of fresh air at the rate of minimum 0.35 cubic meter per minute per person. 5.3 The air distribution system should be so designed to ensure that maximum air velocity at 150 mm below duct/ diffuser is 30 m/min and maximum air velocity at the height of 1200 mm above floor level does not exceed 15 m/ min. 5.4 The microprocessor controller shall be mounted in the switch board cabinet of the coach. 6.0 SWITCH BOARD CABINET 6.1 The switch board cabinet will centrally contain all operating elements for switching, controlling, adjusting and monitoring of electrical installations. It comprises of all necessary equipments/components for controlling and protection of following coach systems. i) Pantry appliances ii) Heating, ventilation and air conditioning system iii) Public address system iv) Sanitary system v) Coach lighting system vi) Anti skid device vii) Water supply system viii) Cable insulation monitoring system 6.2 The switch board cabinet also contains regulated battery charger and disconnecting and earthing device. Switch board cabinet shall be as per RCF specification No. EDTS 073 Rev. B. 6.3 The following measuring instruments, luminous signals, switches and keys for diagnosis and operating function shall be mounted on the door of the switch board cabinet: i) Amp. Meter for battery charging /discharging ii) Volt meter for battery voltage iii) Volt Meter for 3 phase supply, mains 1 iv) Volt Meter for 3 phase supply, mains 2 v) Amp. Meter for 3 phase current

13 Page 13 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) vi) Luminous signals for operation/failure vii) Volume control for public address system viii) Operating and display element for air conditioning system ix) Display of water raising system x) Insulation test etc. 6.4 The coach shall be provided with a power control, distribution, feeder changeover, disconnecting and earthing device, regulated battery charger, microprocessor controller for RMPUs in a Electrical Cubicle. The cubicle shall be provided with five different supply voltage systems isolated from each other i.e. 750V, 415V, 240V, 110V and 24V-supply system. 6.5 A switch shall be provided on switch board cabinet in easily accessible location for switching off the incoming supply to the coach. 6.6 The disconnecting and earthing device shall be capable to connect/disconnect ON load but it is used after the load is switched off. This device is provided for safety of the maintenance staff. The switch should earth the supply system in disconnected position. 6.7 An IGBT based constant voltage constant current (CVCI) regulated battery charger shall be provided in the switch board cubicle, conforming to RCF specification No. EDTS-074 (Rev.A) for charging the 110V battery. 6.8 The cubicle will have all the protective systems for all the electrical equipment of the coach as provided in the imported coaches from M/s. ALSTOM LHB. 6.9 Precautions shall be taken to prevent the access of passengers to any portion of electric circuits where there is danger from electric shock and any metal, handrail or metallic substance liable to be handled by passenger, becoming charged All the support members and metallic structure of cabinet shall be properly earthed to the coach body The general design of the switch board cabinet should meet the following requirement of UIC The switch board cabinet must be provided with one or several doors so as not to be accessible to passengers.

14 Page 14 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) (a) (b) (c) (d) (e) (f) (g) (h) (j) It must be possible to open the outer doors by means of socket key. The switch board cabinet must be arranged in two sections one for train staff and one for maintenance staff. The assembly unit, which is subjected to the voltage higher than the permissible contact voltage, must receive special protection against accidental contact. In the section for maintenance staff, it is recommended that particularly important component which must undergo circumstances be touched should be consequently protected. Equipments accessible only to maintenance staff must only be accessible by opening all doors of cabinet. Green push buttons will be used for switching ON and red push buttons for switching OFF. The operating and control switches grouped on the control panels must carry clear inscription. All electrical and electronic equipments in the switch board cabinet must have a marking. The marking may be numerical or alphanumeric provided that it confirms to wiring diagram and should allow the function of the equipment together with the fault locating instructions, to be easily understood and maintenance staff to be informed of malfunction as precisely as small. All locations of fuses must bear an inscription indicating the normal current density, their references in the wiring diagram and also the power intake circuit protected. This inscription must be provided even if fuse concern is not in place. The door of the switch board cabinet must be so designed that when open during use of the equipment and control panel, they do not interfere with the operation of the automatic door situated in the area and do not hamper passenger s movement more than a minimum The cubicle should be made from fire proof material with provision of lock to prevent unauthorised entry. It should be weather proof for working conditions of the coach. 7.0 REGULATED BATTERY CHARGER 7.1 The battery charger is provided for charging 110V, 70 Amp. Hour battery and feeding the various control supplies and electrical loads working at 110V, DC

15 Page 15 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) supply. The charger is supplied with 415V, 3 phase supply. The charger will be as per RCF specification No. EDTS-074 (Rev.A). It also gives 110V AC for lavoratory and switch board cabinet fans, lights and electric razor sockets etc. 8.0 PUMP EQUIPMENT WITH PLC CONTROLLER AND PUMP BOX 8.1 The requirement of water supply in the coach will be met with the help of twopump equipment with PLC controller, which will continuously pump the water from two 685 liters capacity water tank mounted in under frame to the overhead tanks. The pump equipments will work with 415V 3-phase supply and a programmable logic controller will control their functioning. The pump equipment with PLC controller will confirm to RCF specification No. EDTS-094 (Rev. A). The sensor will be provided for dry run protection. Both pump will be working alternatively. 9.0 BATTERY 9.1 The coach will be provided with a battery of 110V, 70 Amp. Hour for supplying the emergency loads of the coach during failures of normal supply of the coach. The battery tank will contain the temperature sensor for monitoring electrolyte temperature that is used to control the charging of the battery for reducing gassing and loss of water. The battery will be as per RCF specification No. EDTS TRANSFORMER 60 KVA, 750/415V, 3PH, 50HZ phase 750V distribution supply voltage for the coach is stepped down to 415V, three phase supply by using a 60 KVA transformer. The transformer will have stainless steel housing with IP 21 protection. The insulation and terminal box will have IP 65 protection. Transformer will confirm to RCF specification No. EDTS ZS COUPLER Each coach will have two set of ZS coupler (inter vehicle coupler) provided on either end of the coach. The couplers with five poles, three phase four wires supply of 750V and two control cables shall be provided at the end walls of the coach at the same location as provided in imported coaches from M/s. Alstom LHB, Germany. The terminal box will have IP-65 protection. The ZS couplers shall confirm to RCF specification No. EDTS-105 (Rev.C).

16 Page 16 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) 12.0 EARTHING 12.1 The electrical supply system of the coach will follow the concept of earthing and protection against shock to the user. As per Para 61 of IE rules the star connected system with earthed neutral or delta connected system with earthed artificial neutral point, the neutral point of every generator and transformer shall be earthed by connecting it to the earthing system as defined in rule 61 (4) and herein above by not less than 2 separate connections The generator will have earthed neutral providing a TN-net. The electrical couplers of external power cars and passenger s coaches are fitted with four mains power contactors so that TN-net is continued to each car and coach transformer The 60 KVA transformer will operate, as isolation transformer and secondary side is not earthed neutral thus providing IT-net according to IEC As no active net conductor is directly earthed, incase of insulation failure only a low fault current caused by capacitance to earth can flow. The series fuses and circuit breaker do not response to this fault current and supply is maintained even in case of single line earth fault. In case of second fault in another device, one of the faulty devices with fuse or MCB having the lower current capability should be isolated before the permissible contact voltage of 50 V is reached For earthing of metal parts of the coach to ensure safety of passengers the various aspect of earthing should be followed as per UIC All the metal parts of the vehicle liable to be touched by persons and also by animals and in which excessive contact voltage are likely to be persist, for e.g. due to defect in the electrical installation of the vehicle or from the suspended parts of the category must be at the same potential as the rail, using connections, offering the lowest possible resistance for this purpose The electrical resistance between metal parts and the rail must not exceed 0.05 ohm when measured with a current maintained constantly at 50 Amps with a voltage of 50V or less In compliance to the IE rule 64(A) earth protection system should diconnect the system automatically in case the earth fault current exceeds the limit of current for keeping the contact potential within reasonable limits.

17 Page 17 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) 12.9 When the use of the materials which are poor conductors of electricity, for e.g. in pivot bearings or axle boxes, do not allow the value specified above to be obtained the following protective earthing must be provided. - The body to be connected to frame at two different points at least. - The frame to be connected to each bogie at least at one point. - Each bogie must be earthed through atleast one wheel set through the casing of an axle box or by means of an earthing brush The earth connections, which can be bare or insulated must be flexible and corrosion resistant. They must be easy to repair and positioned so that they can not suffer mechanical damage Metal parts fitted to the roof and connected to conducting components inside the vehicle from where they are accessible must be earthed reliably to the vehicle body The metal parts of current consuming apparatus of an installation must be earthed to vehicle in a reliable manner As per rule 70 of IE rules, suitable provision shall be made for immediate and automatic discharge of every static condenser on disconnection of supply The section of the earthing cables depends on that of the conductor through which the current passes. It must be dimensioned to guarantee reliable functioning of circuit breakers in the event of the failure As per rule 32 of IE rules, an indication of permanent nature shall be provided by the owner of the earthed or earthed neutral conductor or the conductor which is to be connected thereto, to enable such conductor to be distinguished from any live conductor. No cut out link or switch other than link switch arranged to operate simultaneously on the earthed or earthed neutral conductor and live conductors shall be inserted or remain inserted in any earthed or earthed neutral conductor of a multi wire system or in any conductor connected their to with the exception of a link switch for testing or a switch for use in controlling a generator or transformer As per IE rule 33, an earthed terminal should be provided at the point of commencement of supply in the coach. All the earthed wires should be provided to have protection against mechanical damages.

18 Page 18 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) For compliance to IE rule 34, no bare conductor should be used and if at all used, they should not be accessible In compliance to rule 61(3) of I.E rule, all matel casing of metallic covering containing or protecting any electric supply line or apparatus shall be connected with earth and shall be so joined and connected across all junctions, boxes and other openings to make good mechanical and electrical connections through out the whole length for earthing As per rule 48 of IE rules, for all the equipments working at low and medium voltage, insulation between each live conductor and earth should be more than one mega ohm with 500V DC applied for a period of one minute. For high voltage equipments, the insulation resistance should be above 5 Mega ohms when 2.5 KV is applied for more than 1 min As per rule 67 of IE rules, all non current carrying metal parts associated with high voltage installations shall be effectively earthed to grounding system which will limit the touch and step potential to tolerable values. It will also limit ground potential rise to tolerable values so as to prevent danger due to transfer of potential through ground, earth wires, cable sheath, pipe lines etc. It will maintain the resistance of earth connection to such a value as to make operation of the protective device INSULATION MONITORING DEVICE 13.1 Insulation Monitoring Device shall be provided as in the imported LHB Coaches, which gives indication in case the insulation of the system is less than the preset value of the device Insulation measuring device monitors the insulation resistance of unearthed AC and 3 phase mains (IT-NETs) A measuring DC voltage is created in the device. The positive pole of measuring device is applied to the mains, which is to be monitored, and the negative pole is applied to earth through an electronic measuring circuits These terminals are permanently monitored and in case of failure (when ohmic insulation between mains and earth falls below the preset value and closes the measuring circuits) a signal LED flashes and a luminous display on the switch cabinet door is activated.

19 Page 19 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) 14.0 ELECTRICAL WIRING 14.1 Superstructure wiring shall be routed in PVC rigid conduit/trenches. Under frame wiring and 750V, 3 phase supply feeder shall be routed in metallic conduits with IP 68 protection and shall be covered with perforated aluminum cable trays as a primary safe guard against ballast hitting. Junction boards and distribution boards should be provided with suitable inspection covers and shall be easily approachable for maintenance purpose. The coaches shall be wired similar to the imported LHB coaches The wiring on the superstructure as well as on the under frame of the coaches shall be done with thin walled electron beam irradiated cables conforming to RCF specification No. EDTS-132 Rev A EXTERNAL LOCAL SUPPLY 15.1 External Local supply at 415V, 3Ph shall be provided through the sockets provided in the coach. The interlocking of external supply with D.A. set supply shall be provided as per design of imported LHB coaches. A 5-pole plug and socket of 125A rating with pilot contact shall be provided for external supply. The necessary protective mechanism will be provided to prevent shortcircuiting of two supplies and danger to the operating/maintenance staff, which may be similar to imported LHB coaches LIGHTING 16.1 Fluorescent light fittings with 2X18W shall be provided with electronic ballast to work on 110V ac supply as shown in the RCF coach layout LW Fluorescent lamp with electronic ballast shall be as per RDSO specification No. RDSO/PE/SPEC/TL0011 (Rev.I) Reading lights shall be provided with 12V, 10W halogen lamps similar to provided in imported LHB coaches An inverter for reading light shall be provided as per RCF specification No. EDTS Night-lights shall be provided as shown in RCF layout No. LW90006.

20 Page 20 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) 17.0 FANS Exhaust fans shall be provided in the lavatory and switch board cabinet at the locations similar to original imported LHB coaches APPROVAL OF DRAWINGS 18.1 The schematic coach wiring diagram and detailed assembly drawing for equipments shall be submitted by production unit to RDSO for approval. One copy of useful information containing details of various equipments shall also be submitted to RDSO USEFUL INFORMATION AND INSTRUCTION MANUAL 19.1 One copy of useful information containing details of various equipments with layout provided on the coach, commissioning test results, alongwith maintenance and operation details shall be supplied with each coach by coach manufacturer to user railways TEST AND INSPECTION 20.1 The air conditioning system of the coach shall be in general inspected and tested as per RDSO test programme No. ELPS/TP/AC/01 for AC coaches. However the production unit should submit the test schedule for these coaches offered by M/s LHB along with their comments so that the test programme may be approved by RDSO.

21 Page 21 of 21 File No. EL/ Effective from K2-B-01 Pt.II (Electrical) DISTRIBUTION: 1 CEE / Eastern Railway, Fairlie Place, Kolkata 2 CEE / Northern Railway, Baroda House, New Delhi 3 CEE / Central Railway, Mumbai CST 4 CEE / Northeast Frontier Railway, Maligaon, Guwahati 5 CEE / North Eastern Railway, Gorakhpur 6 CEE / South Central Railway, Secunderabad 7 CEE / Southern Railway, Park Town, Chennai 8 CEE / South Eastern Railway, Kolkata 9 CEE / Western Railway, Churchgate, Mumbai 10 CEE / North Central Railway, Hasting Road, Allahabad 11 CEE / Western Central Railway, Jabalpur 12 CEE / Integral Coach Factory, Chennai. 13 CEE / East Coast Railway, Bhuvneshwar 14 CEE / East Central Railway, Hajipur 15 CEE/ Rail Coach Factory, Kapurthala 16 CEE./ North Western Railway, Jaipur 17 Director / IRIEEN, Nasik Road 18 Director / CAMTECH, Gwalior 19 Secy.(Elec.) Railway Board, New Delhi 20 DDSE/DOC. 21 ADE-9 22 Unit Supervisor

RDSO/PE/SPEC/AC/ (Rev. 0 ) SPECIFICATION FOR VANE TYPE AIR FLOW RELAY FOR ROOF MOUNTED AC PACKAGE UNIT

RDSO/PE/SPEC/AC/ (Rev. 0 ) SPECIFICATION FOR VANE TYPE AIR FLOW RELAY FOR ROOF MOUNTED AC PACKAGE UNIT Page 1 of 12 RESEARCH DESIGN & STANDARDS ORGANISATION MINISTRY OF RAILWAY POWER SUPPLY & EMU DIRECTORATE TITLE SPECIFICATION FOR VANE TYPE AIR FLOW RELAY FOR ROOF MOUNTED AC PACKAGE UNIT S.No. Date of

More information

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010 1 of 5. Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010 2 Definitions 2 Not seen the definition for Inspector. But with, - Qualifications,

More information

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL. Estimation and Costing & Utilization of Electrical Energy

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL. Estimation and Costing & Utilization of Electrical Energy 1 SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL Estimation and Costing & Utilization of Electrical Energy Estimation and Costing & Utilization of electrical Energy Estimation

More information

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES MINISTRY OF LABOUR, INDUSTRIAL RELATIONS AND EMPLOYMENT GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES Occupational Safety & Health Inspectorate These guidelines should be used with approved standards:

More information

Chapter 14:08 Factories and Works (Electrical) Regulations, Chapter 14:08 Factories and Works (Electrical) Regulations, 1976

Chapter 14:08 Factories and Works (Electrical) Regulations, Chapter 14:08 Factories and Works (Electrical) Regulations, 1976 1 Title Chapter 14:08 Factories and Works (Electrical) Regulations, 1976 2 Interpretation of terms 3 Fencing and enclosure 4 Notices 5 Safety precautions 6 Switch-boards 7 Portable electric tools and lights

More information

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

This standard covers the requirements of lighting chains. This standard covers only the safety requirements. FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements

More information

RSC-G-004-B Guidelines For The Design Of Section 3 3 ELECTRIC TRACTION SYSTEMS 2

RSC-G-004-B Guidelines For The Design Of Section 3 3 ELECTRIC TRACTION SYSTEMS 2 3 ELECTRIC TRACTION SYSTEMS 2 3.1. SAFE FOR PEOPLE 2 3.1.1. Electric Traction System 2 3.1.2. Protection against unwanted access 2 3.1.3. Fencing 2 3.1.4. On bridges and other structures 2 3.1.5. At level

More information

PUBLIC NOTICE. 1. Central Electricity Authority (Technical Standards for Connectivity of Distributed Generation Resources) Regulations, 2013.

PUBLIC NOTICE. 1. Central Electricity Authority (Technical Standards for Connectivity of Distributed Generation Resources) Regulations, 2013. GOVERNMENT OF INDIA CENTRAL ELECTRICITY AUTHORITY (MINISTRY OF POWER) 6 th Floor (N), Sewa Bhawan, R. K. Puram, New Delhi-110066 Tel. Fax: 26103246, e.mail: celegal-cea@gov.in, website: www.cea.nic.in

More information

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID S.NO. HEAD DESCRIPTION AMOUNT (Rs.) 1 A DG SETS & ACCESSORIES

More information

33KV INDOOR SWITCHGEAR

33KV INDOOR SWITCHGEAR 33KV INDOOR SWITCHGEAR September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN:

More information

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements 1. PURPOSE sponsored by ABYC, BMF, ICOMIA, IMCI, and NMMA Author: Wieger de Wit Guideline Number 3 Electrical

More information

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

56-SDMS-07 REV. 01 SPECIFICATIONS FOR 56-SDMS-07 REV. 01 SPECIFICATIONS FOR UNIT SUBSTATIONS UP TO 36 kv ALUMINUM TRANSFORMER ALUMINUM BUS BARS LVDP This specification is property of SEC and subject to change or modification without any notice

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

Net +Plus Connection Code

Net +Plus Connection Code Net +Plus Connection Code LANKA ELECTRICITY COMPANY (PRIVATE) LIMITED 1.0 BACKGROUND The existing Net Metering Concept launched in the year 2010 noticed an exponential growth in the recent year and at

More information

ANNEXURE XI. (Ni Cd Battery Bank) TECHNICAL SPECIFICATIONS OF 125V STATION BATTERY BANK OF GTG I.

ANNEXURE XI. (Ni Cd Battery Bank) TECHNICAL SPECIFICATIONS OF 125V STATION BATTERY BANK OF GTG I. ANNEXURE XI (Ni Cd Battery Bank) TECHNICAL SPECIFICATIONS OF 125V STATION BATTERY BANK OF GTG I. Sr. No Technical Particulars Confirmation to be given by bidder (Please strike out which ever not applicable)

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations Version:- 3.0 Date of Issue:- Dec 2013 Page 1 of 13 NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations 1. Purpose This document is the technical specification

More information

Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum. FOREWORD This Standard is intended to be used within and for Iranian Ministry of Petroleum (N.I.O.C, N.I.G.C, N.P.C., N.I.O.R.D.C. and other affiliate organizations and companies) and has been prepared

More information

All Priciple Secretary/ Secretary, State Power Depratments/ UTs. (As per list enclosed)

All Priciple Secretary/ Secretary, State Power Depratments/ UTs. (As per list enclosed) भ रत सरक र Government of India व द य त म त र लय Ministry of Power क द र य व द य त प र व करण Central Electricity Authority म ख य व द य त व र क षण लय प रभ ग Chief Electrical Inspectorate Division Telefax:

More information

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA

017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA 017: 1998 CEB STANDARD RING MAIN UNIT CEYLON ELECTRICITY BOARD SRI LANKA CONTENTS PAGE 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable Standards 3 5. Basic Features 4 6. Quality

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli 620014, TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT ENQUIRY NOTICE INVITING TENDER Phone:

More information

Guidance for Low Voltage Electrical Installations

Guidance for Low Voltage Electrical Installations Guidance for Low Voltage Electrical Synopsis This document provides information in support of GI/RT7007 Low Voltage Electrical. Signatures removed from electronic version Submitted by Anne E Blakeney Standards

More information

E-12 Low-voltage Switchboard

E-12 Low-voltage Switchboard Guideline No.E-12 (201510) E-12 Low-voltage Switchboard Issued date: 20 October 2015 China Classification Society Foreword This Guide is a part of CCS Rules, which contains technical requirements, inspection

More information

Chapter 6 Generator-Voltage System

Chapter 6 Generator-Voltage System Chapter 6 Generator-Voltage System 6-1. General The generator-voltage system described in this chapter includes the leads and associated equipment between the generator terminals and the low-voltage terminals

More information

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI BHARAT HEAVY ELECTRICALS LIMITED, JHANSI DESIGN, MANUFACTURING, TESTING, SUPPLY INSTALLATION AND COMMISSIONING OF 11KV VACUUM CIRCUIT BREAKER NOTE : 1 VENDOR must submit complete information against clause

More information

Title High Voltage and 1500 System Earthing References and Definitions. Reference Number PDS 02 (RIC Standard: EP SP)

Title High Voltage and 1500 System Earthing References and Definitions. Reference Number PDS 02 (RIC Standard: EP SP) Discipline Engineering Standard NSW Category Electrical Title High Voltage and 1500 System Earthing References and Definitions Reference Number PDS 02 (RIC Standard: EP 12 00 00 01 SP) Document Control

More information

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

More information

FUNDAMENTALS OF POWER DISTRIBUTION SAIEE-1337-V : 2 CPD credits : Category 1

FUNDAMENTALS OF POWER DISTRIBUTION SAIEE-1337-V : 2 CPD credits : Category 1 THE SOUTH AFRICAN INSTITUTE OF ELECTRICAL ENGINEERS FUNDAMENTALS OF POWER DISTRIBUTION SAIEE-1337-V : 2 CPD credits : Category 1 OVERVIEW : 1. Introduction to Distribution, Transmission and Generation

More information

Periodic comprehensive review of the CEA (Measures relating to Safety and Electric Supply) Regulations, 2010 (as amended)

Periodic comprehensive review of the CEA (Measures relating to Safety and Electric Supply) Regulations, 2010 (as amended) Periodic comprehensive review of the CEA (Measures relating to Safety and Electric Supply) Regulations, 2010 (as amended) Revised draft amendment based on the comments received over previous uploaded draft

More information

ECS CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS

ECS CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS Network(s): Summary: ENGINEERING CONSTRUCTION STANDARD ECS 03-0054 CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS EPN, LPN, SPN This standard details the procedures to be undertaken

More information

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application The most advanced Arc-Resistant Switchgear, designed and built to provide maximum safety in the event of an Internal Arcing Fault. 5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application Page 1

More information

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 1 OF 7 TECHNICAL SPECIFICATION FOR 11 KV.CAPACITOR BANK 1.0 SCOPE: This specification covers

More information

Technical Specifications

Technical Specifications LT Distribution Box Technical Specifications 1. SCOPE 1.1 This specification covers design, manufacture, testing at manufacturer works before dispatch and supply of L.T. Distribution Cabinet suitable for

More information

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001 CLP POWER HONG KONG LIMITED SUPPLY March 2001 ADVISORY SERVICE Advice concerning matters relating to the supply of electricity may be obtained free of charge from the Company. OTHER COMPANY PUBLICATIONS

More information

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) 1 SCOPE OF SUPPLY This specification covers design, manufacture, shop

More information

KENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO

KENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO BILL 1 MAINS POWER DISTRIBUTION 2-1 ITEM DESCRIPTION QTY UNIT RATE AMOUNT Supply, install, test, commission and set to work the following:- 1.01 Free-standing purpose made front access sub main switchboard

More information

CENTRAL ELECTRICITY AUTHORITY (MEASURES RELATING TO SAFETY AND ELECTRIC SUPPLY) REGULATIONS, 2010

CENTRAL ELECTRICITY AUTHORITY (MEASURES RELATING TO SAFETY AND ELECTRIC SUPPLY) REGULATIONS, 2010 CENTRAL ELECTRICITY AUTHORITY (MEASURES RELATING TO SAFETY AND ELECTRIC SUPPLY) REGULATIONS, 2010 2 INDEX Chapter - I Definitions 1 Short title and Commencement 2 Definitions Chapter - II 3 Designating

More information

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR

More information

Pretest Module 24 Three-phase Service Entrance

Pretest Module 24 Three-phase Service Entrance Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?

More information

Requirements for Secondary Voltage Revenue Metering (750 V and less)

Requirements for Secondary Voltage Revenue Metering (750 V and less) Requirements for Secondary Voltage Revenue Metering (750 V and less) To view the latest revision of this document go to: http://www.bchydro.com/ext/metering/ January 28, 2010 Copyright 2008 by BC Hydro.

More information

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.

More information

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show.

3 o/c 2 An area or temporary structure used for display, marketing or sales is defined as a a booth b a stand c an exhibition d a show. 1 PAPER 7 Sample Questions - C&G 2382 17th Edition paper C 1 o/c 1 - BS 7671 relates to permanent and temporary installations for equipment on: a marinas. b ships. c equipment on aircraft. d railway traction

More information

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI SERVICE REQUIREMENTS This section discusses the requirements for establishing electric service to new residential subdivisions in Palo Alto. Subdivisions are normally constructed on dedicated

More information

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as an AMENDMENT)

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as an AMENDMENT) Doc: ET 25(6345) BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY (Not to be reproduced without the permission of BIS or used as an AMENDMENT) DRAFT AMENDMENT NO. 3 TO IS 14665 (Part 2 / Sec 1) : 2000

More information

Operating procedures relating to the use of electrical equipment and installations

Operating procedures relating to the use of electrical equipment and installations Operating procedures relating to the use of electrical equipment and installations Reviewed November 2014. These operating procedures apply to all University staff with respect to electrical safety. Failure

More information

Earthing UNIT. Learning Objectives. Introduction. To understand purpose of Earthing. To learn system of earthing.

Earthing UNIT. Learning Objectives. Introduction. To understand purpose of Earthing. To learn system of earthing. 274 Electrical Technician UNIT 10 Earthing Learning Objectives To understand purpose of Earthing. To learn system of earthing. Introduction The very purpose of earthing is to safe against dangers of shock

More information

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS Prepared by: SXZO DISCONNECT SWITCH REQUIREENTS FOR DISTRIBUTED GENERATION CUSTOERS 060559 Department: Electric Distribution Section: Design and Construction Approved by: D.Jantz (DWJ7) Date: 8/15/17 Rev.

More information

ENGINEERING SPECIFICATION

ENGINEERING SPECIFICATION December 206 ENGINEERING SPECIFICATION No. of 6 DATE: 2-9-6 CATEGORY SUBJECT TABLE OF CONTENTS. Overview... 2 2. General Requirements for Service... 3 3. Definitions... 3 4. Abbreviations... 5 5. References

More information

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

More information

२१७१ २-१ ४४ २०१८ २-१ २१०९-४ २०१८ २९ ०६ २०१८ २ २ १२४९ २-१ ४४ २०१८ २१ ०७ २०१८ ३ २ १७०५ २ / -१ ४४ २०१८ १० १० २०१८ १ २ ३ २ ३ १३ २०१८-१९

२१७१ २-१ ४४ २०१८ २-१ २१०९-४ २०१८ २९ ०६ २०१८ २ २ १२४९ २-१ ४४ २०१८ २१ ०७ २०१८ ३ २ १७०५ २ / -१ ४४ २०१८ १० १० २०१८ १ २ ३ २ ३ १३ २०१८-१९ २१७१ २-१ ४४ २०१८ २ :- (०७१७२)२२७३८२-४४२४०३ - (०७१७२)२२७३८२ - mlidn2@rediffmail.com ३१ / १२ २०१८ - - १ २१०९-४ २०१८ २९ ०६ २०१८ २ २ १२४९ २-१ ४४ २०१८ २१ ०७ २०१८ ३ २ १७०५ २ / -१ ४४ २०१८ १० १० २०१८ ------000-----

More information

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear ATLV MaxSG Low Voltage Metal Enclosed Switchgear ABB, INC. Product General Description MaxSG Switchgear ABB MaxSG switchgear is a further continuation in the development of innovative products from ABB,

More information

Amendment of UN ECE R100 regarding in-use requirements for vehicles of category L Status:

Amendment of UN ECE R100 regarding in-use requirements for vehicles of category L Status: 0 1. Scope The following prescription apply to safety requirements with respect to the electric power train of road vehicles of categories M and N, with a maximum design speed exceeding 25 km/h and vehicles

More information

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST Use & Identification of Grounded and Grounding Conductors YES NO N/A Grounded conductors are identifiable and distinguishable from all other conductors.

More information

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA 023 : 2006 CEB STANDARD 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA Specification for 12kV & 36kV LOAD BREAK SWITCHES CEB Standard 023 : 2006 CEYLON ELECTRICITY BOARD No. 50, Sir

More information

E-12 Low-voltage Switchboard

E-12 Low-voltage Switchboard Guideline No.E-12 (201705) E-12 Low-voltage Switchboard Issued date: May 9, 2017 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains technical requirements, inspection

More information

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP)

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP) Discipline Engineering Standard NSW Category Electrical Title Low Voltage Distribution and Installations Earthing References and Definitions Reference Number PDS 03 (ARTC Standard: EP 12 00 00 02 SP) Document

More information

SPECIFICATION FOR REWIRABLE FUSES (KITKAT FUSES) 100A & 200A SPECIFICATION NO.: DIST/ A- KIT /

SPECIFICATION FOR REWIRABLE FUSES (KITKAT FUSES) 100A & 200A SPECIFICATION NO.: DIST/ A- KIT / SPECIFICATION FOR REWIRABLE FUSES (KITKAT FUSES) 100A & 200A SPECIFICATION NO.: DIST/ A- KIT / 2005-06 SR.NO ITEM PAGE 1. SCOPE 2 2. WEATHER CONDITIONS 2 3. RATED VOLTAGE & FREQUENCY 2 4. GENERAL REQUIREMENT

More information

TECHNICAL SPECIFICATION FOR D G SET KVA

TECHNICAL SPECIFICATION FOR D G SET KVA GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATION FOR D G SET - 250 KVA GETCO/ENGG/TS/ DG Set 250 KVA Dt.01.08.14 1 DIESEL

More information

Approved Meter Sockets and Cabinets

Approved Meter Sockets and Cabinets Single Unit Residential Guide 1 PHASE, 120/240 VOLT SERVICES SERVICE CAPACITY OWNED METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to

More information

Central Battery Systems Loadstar AC/DC Systems

Central Battery Systems Loadstar AC/DC Systems The Loadstar range of AC/DC central battery units comply with the latest relevant European and British standards. High quality, cost effective units provide secure sources of emergency power for escape

More information

Three-Phase Pole Mounted Recloser

Three-Phase Pole Mounted Recloser Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE

More information

.3 Section Waste Management and Disposal.

.3 Section Waste Management and Disposal. Issued 2005/06/01 Section 16261 Uninterruptible Power Systems Static Page 1 of 10 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01780 Closeout Submittals..3 Section

More information

Dakshin Gujarat Vij Company Limited

Dakshin Gujarat Vij Company Limited Dakshin Gujarat Vij Company Limited CIN U40102GJ2003SGCO42909 Regd. & Corporate Office: Urja Sadan, Nana Varachha Road, Kapodara Char Rasta,Surat 395 006 C & R DEPARTMENT Phone No.: 0261 2506100-200-175

More information

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS 1. PURPOSE AND SCOPE OF THIS DOCUMENT... 3 2. DEFINITIONS...

More information

Effective discrimination of protective devices

Effective discrimination of protective devices Effective discrimination of protective devices In the event of a fault occurring on an electrical installation only the protective device nearest to the fault should operate,leaving other healthy circuits

More information

VD4 Installation and service instructions kv A ka

VD4 Installation and service instructions kv A ka Medium voltage products VD4 Installation and service instructions 12... 36 kv - 630... 3150 A - 16... 50 ka Index For your safety! 1 I. Introduction 2 II. Programme for environmental protection 2 1. Packing

More information

33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT

33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT 33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar,

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 3112:2011 AS/NZS 3112:2011 Australian/New Zealand Standard Approval and test specification Plugs and socket-outlets AS/NZS 3112:2011 This Joint Australian/New Zealand Standard was prepared by Joint

More information

E/ECE/324/Rev.2/Add.104/Rev.2/Amend.3 E/ECE/TRANS/505/Rev.2/Add.104/Rev.2/Amend.3

E/ECE/324/Rev.2/Add.104/Rev.2/Amend.3 E/ECE/TRANS/505/Rev.2/Add.104/Rev.2/Amend.3 26 July 2017 Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be Used on Wheeled Vehicles and the Conditions for

More information

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference. Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University Safety Office Reviewed: 17 July 2012 Reviewed: DD Month University Code of Practice for Electrical Safety PART B - Design and Construction of Electrical Equipment within the University The purpose of this

More information

SYLLABUS FOR ELECTRICAL SUPERVISOR CERTIFICATE OF COMPETENCY (SCC MV) Electrical Engineering Paper (Written Test)

SYLLABUS FOR ELECTRICAL SUPERVISOR CERTIFICATE OF COMPETENCY (SCC MV) Electrical Engineering Paper (Written Test) ANNEXURE I SYLLABUS FOR ELECTRICAL SUPERVISOR CERTIFICATE OF COMPETENCY (SCC MV) Electrical Engineering Paper (Written Test) Paper I & Paper II for General Category of S.C.C. Examination Paper I & Paper

More information

GT/TDINT100 Issue: 1 Date: SEP 1993 Page 1 of 11

GT/TDINT100 Issue: 1 Date: SEP 1993 Page 1 of 11 British Railways Board Group Standard Page 1 of 11 Part A Synopsis This Directive gives the general requirements of telecommunications earthing systems, and encompasses the requirements for the earthing

More information

NPS/003/002 Technical Specification for 30V Distribution Tripping Battery and Charger Systems

NPS/003/002 Technical Specification for 30V Distribution Tripping Battery and Charger Systems Version:- 2.1 Date of Issue:- July 2016 Page 1 of 29 NPS/003/002 Technical Specification for 30V Distribution Tripping Battery and Charger Systems 1. Purpose This document is to detail the technical requirements

More information

University of California, San Diego Cal (IT) 2 Technical Assignment #2. Brian Smith

University of California, San Diego Cal (IT) 2 Technical Assignment #2. Brian Smith University of California, San Diego Cal (IT) 2 Technical Assignment #2 Brian Smith Advisor: Dr. Moeck 31 October 2005 Brian Smith Lighting/Electrical Option University of California, San Diego Cal (IT)

More information

E-15 Uninterruptible Power Systems (UPS)

E-15 Uninterruptible Power Systems (UPS) Guideline No.E-15 (201510) E-15 Uninterruptible Power Systems (UPS) Issued date:20 October, 2015 China Classification Society Foreword This Guide is a part of CCS Rules, which contains technical requirements,

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

(i) in paragraph 9, for sub-paragraph (i) the following shall be substituted, namely:-

(i) in paragraph 9, for sub-paragraph (i) the following shall be substituted, namely:- Revision 3 Date: 28/01/2016 Amendment to Schedule 6 for Induction Motor In the said schedule, (i) in paragraph 9, for sub-paragraph (i) the following shall be substituted, namely:- Effective from 1 st

More information

Mass Sine 24/10000 Mass Sine 24/15000

Mass Sine 24/10000 Mass Sine 24/15000 USERS- AND INSTALLATION MANUAL Mass Sine 24/10000 Mass Sine 24/15000 Modular high power inverter system MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands ENGLISH: PAGE 1 Tel.: +31-20-342

More information

Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9

Chapter 2 Wiring and Protection Article 200 Use and Identification of Grounded Neutral Conductor Chapter 1 General...9 Article 90 Introduction...1 90.1 Purpose of the NEC...1 90.2 Scope of the NEC...2 90.3 Code Arrangement...4 90.4 Enforcement...5 90.5 Mandatory Requirements and Explanatory Material...6 90.6 Formal Interpretations...6

More information

PART 10 ELECTRICAL INSTALLATIONS

PART 10 ELECTRICAL INSTALLATIONS PART 10 ELECTRICAL INSTALLATIONS SECTION SUBJECT 10.1 General 10.2 Cables 10.3 DC systems 10.4 Batteries 10.5 AC systems 10.6 Earthing and bonding 10.7 Motor control 10.8 Lighting 10.9 Remote stops 10.10

More information

Marina Bay Sands Guidelines for Electrical and Wiring Service

Marina Bay Sands Guidelines for Electrical and Wiring Service Marina Bay Sands Guidelines for Electrical and Wiring Service 1) The supply of electrical mains in the licensed area of the event is an exclusive service offered by Marina Bay Sands (MBS). In the event

More information

SCHEDULE OF QUANTITY

SCHEDULE OF QUANTITY SCHEDULE OF QUANTITY ELECTRICAL WORKS PM PALEM BRANCH, VISAKHAPATNAM SL NO. DESCRIPTION OF ITEM / WORK UNIT Qty RATE AMOUNT PART - A : ELECTRICAL WORKS 1 Energy Meter Cubicle : 2 Emergency Off Box (Red

More information

Amendments in Technical Specification No. S-137/DD-177 July 2007 for 11KVAutomatic Switched Capacitor bank at Sub-Stations (33/11KV).

Amendments in Technical Specification No. S-137/DD-177 July 2007 for 11KVAutomatic Switched Capacitor bank at Sub-Stations (33/11KV). Amendments in Technical Specification No. S-137/DD-177 July 2007 for 11KVAutomatic Switched Capacitor bank at Sub-Stations (33/11KV). Sr. No. Clause No Existing Proposed 1 8.0 Dischar ge device 2 15.0

More information

The following are specific provisions of 1910(a)(2) that could be seen in the LBM sector

The following are specific provisions of 1910(a)(2) that could be seen in the LBM sector Know the Rules on Temporary Wiring OSHA Standard 1910.305, Wiring methods, components, and equipment for general use, addresses wiring methods, components, and equipment for general use as one of several

More information

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society Guideline No.: E-07(201712) E-07 TRANSFORMERS Issued date: December 26, 2017 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection

More information

EMPAC Metal enclosed capacitor bank for wind applications

EMPAC Metal enclosed capacitor bank for wind applications EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

FACT SHEET Standard: Electrical Safety

FACT SHEET Standard: Electrical Safety What is a Ground Fault Circuit Interrupter? FACT SHEET The ground-fault circuit interrupter, or GFCI, is a fast-acting circuit breaker designed to shut off electric power in the event of a ground-fault

More information

Rapid Response. Lineside Signal Spacing. Railway Group Standard GK/RT0034 Issue Three Date September 1998

Rapid Response. Lineside Signal Spacing. Railway Group Standard GK/RT0034 Issue Three Date September 1998 Rapid Response Railway Group Standard Lineside Signal Spacing Synopsis This Standard specifies the minimum distance that must be provided between the first signal displaying a cautionary aspect and the

More information

CHAPTER V RESIDENTIAL WIRING

CHAPTER V RESIDENTIAL WIRING CHAPTER V RESIDENTIAL WIRING 5.1. THE SERVICE ENTRANCE Buildings and other structures receive the electrical energy through the service entrance. In residential wiring, the electric company supply this

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Books. Code of Practice for In-Service Inspection and Testing of Electrical Equipment (3rd edition) By IET Publication

Books. Code of Practice for In-Service Inspection and Testing of Electrical Equipment (3rd edition) By IET Publication Books Code of Practice for In-Service Inspection and Testing of Electrical Equipment (3rd edition) By IET Publication Available: 2008 Format: Paperback Product Code: PWR08630 ISBN: 978-0-86341-833-4 Pagination:

More information

TECHNICAL SPECIFICATIONS OF PCC PANEL

TECHNICAL SPECIFICATIONS OF PCC PANEL S. no. TECHNICAL SPECIFICATIONS OF PCC PANEL Technical parameters AS PER SPECIFICATION CONSTRUCTIONAL FEATURES TO BE FILLED BY THE SUPPLIER 1 Manufacturer s name To be specified by supplier 2 Rated operational

More information

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011 Page 1 of 6 STANDARD SPECIFICATION FOR LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs Rev No. Issue Date Pages Rev Description Prepared By Checked By Approved By 0 15.07.2008 6 Issued for FEED MSJ VDV VDV

More information

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT 1.0 PURPOSE: 1. To charge the battery bank through Solar PV source and AC supply. 2. To invert and produce utility quality sine wave. 3. Inverters

More information

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE Certificate Number FM35831 APPLICATION Typical Uses and Classification The MSGair switchgear is used in transformer and switching substations mainly

More information

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear 13 Low Voltage Switchgear Siemens Type WL low voltage metal-enclosed switchgear is designed, constructed and tested to provide superior power distribution, power monitoring and control. At the heart of

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information