1 Merlin Gerin ew Watt-hour meter
2 2002 Building regulations On 1st April 2002 the new Approved Document L2 of the Building Regulations came into effect. This document is concerned with the conservation of fuel and power in buildings other than dwellings. Section 3 of this document is concerned with the provision of information to the building owner and/or occupier to enable energy consumption to be monitored and controlled. The document makes proposals of how the Regulations can be met. Sufficient energy meters should be installed to enable actual energy consumption to be measured. At least 90% of the annual energy consumption should be accounted for, either by calculation or by actual measurement. Recommendations are made about the size of plant that should have separate metering: Rated input power Boiler installations 50kW Chiller installations 20kW Electric humidifiers 10kW Motor control centres feeding fans and pumps 10kW Final electrical distribution boards 50kW These recommendations indicate that quite small loads should be measured to enable energy conservation actions to be taken. ew range of modular watt-hour meters The Merlin Gerin range of ME watt-hour meters are ideally suited for measuring the energy taken by these loads. The meters are small modular type, easily fitted into distribution boards or individual enclosures. They have a non-resettable main display with options for a resettable secondary display and a pulse output for remote energy recording. For simplicity, loads up to 63A may be direct connected. Higher loads are measured using current transformers, the ratio of which is programmed into the meter at the commissioning stage. The available ratios range from 40/5 up to 6000/5. The meters are of modular dimensions, mounted onto symmetrical DI rail with all displays and settings on the front face. 2
3 Benefits Ideally suited for check metering and allocating costs Provides information on energy consumption Helps the industrial, commercial and tertiary sectors meet the requirements of the Building Regulations (Part L2) by identifying where energy is being used Helps identification of inefficient and wasteful equipment Reduced size allows installation within existing equipment or in small extension boxes. Features ew range of watt-hour meters Easy to read digital display Small modular size DI rail mounted Direct connected up to 63A Current transformer operated, ratios from 40/5 to 6000/5 Ratio programmed by installer Very low burden Liquid crystal main display, non-resettable Optional partial display, resettable Optional pulse output for remote metering Easy installation into distribution boards Suitable for 240V single phase and 415V three phase supplies Tropicalised: 95% relative humidity at 55 o C. 3
4 Watt-hour meters ME Watt-hour meters (rms) are designed for the measurement of energy consumed by an electrical load, single phase, three phase 3 wire or three phase 4 wire. Common technical data Accuracy class: 2 Frequency: 50/60 Hz Consumption: 2.5 VA Total meter: On one phase (single-phase network), on the 3 phases (three-phase network) capacity : - ME1, ME1z, ME1zr, ME3, ME3zr, ME4, and ME4zr: MWh - ME4zrt associated with a CT rating < 150 A: MWh - ME4zrt associated with a CT rating > 150 A: MWh Display: in or MWh with 5 significant digits Partial meter: On a phase (single-phase network), on the 3 phases (three-phase network) With RESET Capacity: - ME1z, ME1zr, ME3zr, and ME4zr: MWh - ME4zrt associated with a CT rating < 150 A: MWh - ME4zrt associated with a CT rating > 150 A: MWh Display: in or MWh with 4 significant digits Flashing meter indicator (yellow) on front panel Operating temperature: C to C Connection using tunnel terminals: Main connection: 16 mm 2 Secondary connection: 6 mm 2 Conform to IEC 1036 standard (with a sealable enclosure). 4
5 Watt-hour meters ME Extensive range ME1 single-phase watt-hour meter Direct measurement up to 63 A Meter indicator: 1000 flashes per Wiring error indicator. ME1z Single-phase watt-hour meter with partial meter Direct measurement up to 63 A Meter indicator: 1000 flashes per Wiring error indicator. ME1zr Single-phase watt-hour meter with partial meter and pulse output for remote metering Direct measurement up to 63 A Meter indicator: 1000 flashes per Pulse output via.o. contact: Wiring error indicator. ME3 Three-phase watt-hour meter for 3 wire system Direct measurement up to 63 A per phase Meter indicator: 100 flashes per. ME3zr Three-phase watt-hour meter for 3 wire system with partial meter and pulse output for remote metering Direct measurement up to 63 A per phase Meter indicator: 100 flashes per Pulse output via.o. contact. ME4 Three-phase watt-hour meter for 4 wire system Direct measurement up to 63 A per phase Meter indicator: 100 flashes per. ME4zr Three-phase watt-hour meter for 4 wire system with partial meter and pulse output for remote metering Direct measurement up to 63 A per phase Meter indicator: 100 flashes per Pulse output via.o. contact. ME4zrt Three-phase watt-hour meter with or without neutral, with partial meter and pulse output for remote metering, for use with current transformers (not supplied) CT measurement: ratio 40/5 to 6000/5 (configurable) Consumption of each measured input: 0.05 VA at 5 A Meter indicator: 10,000/x flashes per (x = CT rating) example: CT 500/5 = 10,000/500 flashes per = 20 flashes per Pulse output via.o. contact. 5
6 Watt-hour meters ME Selection tables These meters are designed for sub-metering purposes. They measure the electrical energy consumed by single phase or three phase loads and all have a non-resettable total display. Some devices also have a partial display which is resettable. Displays are in or MWh and have 5 significant figures. ME1 ME1z ME1zr ME3 ME3zr ME4 ME4zr ME4zrt Operation Single phase Three phase 3 wire Three phase 4 wire Rated voltage 230V 50/60Hz 1P+ 400V 50/60Hz 3P 230/400V 50/60Hz 3P+ Current measurement Whole current single phase 63A Whole current three phase 63A Using CTs /5 Total meter capacity MWh with /5 CTs 9,999.9 MWh with /5 CTs Partial meter, resettable Pulse output Wiring error indicator Width in 18mm modules * ME4Zrt Selectable current transformer ratios 40/5, 50/5, 60/5, 75/5, 80/5, 100/5, 125/5, 150/5, 200/5,250/5,300/5, 400/5, 500/5, 600/5, 800/5, 1000/5, 1200/5, 1250/5, 1500/5, 2000/5, 2500/5, 3000/5, 4000/5, 5000/5, 6000/5. IP55 sealable transparent cover and flush mounting kit These kits allows one ME3 or 4 (4 modules wide) or one or two ME1 (2 modules wide) meters to be mounted behind a cover on a front panel. The clear cover is hinged and may be retained closed by a wire seal or two M4 screws (not supplied) to deter unauthorised access. The flush mounting kit provides DI rail and supporting brackets on which to mount the meter or meters. Product Transparent cover complete with flush mounting kit Transparent cover only Catalogue no B 99246A 6
7 0,1imp/ 0,1imp/ 1imp/ 230Va50/60Hz 10(63)A CL imp/ 100imp/ 100imp/ 10/ximp/ 10/ximp/ 10000/ximp/ 10000/ximp/ Watt-hour meters ME References Type Rating Voltage rating Cat. no. Width in mod. (A) (V ac) of 18 mm Single phase ME ME1z ME1zr L ME1zr L L L Type Rating Voltage rating Cat. no. Width in mod. (A) (V ac) of 18 mm 3 phase 3 wire ME3 63 3x ME3zr 63 3x ME4zrt (CT) 3x L1 L2 L3 L1 L2 L3 ME3zr 3x400Va50/60Hz 10(63)A CL.2 ME3zrt 3x400Va50/60Hz x/5a CL L1 L1 L2 L2 L3 L3 L1/ L2 L3/ L1 L2 L3 Type Rating Voltage rating Cat. no. Width in mod. (A) (V ac) of 18 mm 3 phase 4 wire ME4 63 3x230/ ME4zr 63 3x230/ ME4zrt (CT) 3x230/ L1 L2 L3 L1 L2 L3 ME4zr 3x230/400Va50/60Hz 10(63)A CL.2 ME4zrt 3x230/400Va50/60Hz x/5a CL L1 L1 L2 L2 L3 L3 L1/ L2/ L3/ L1 L2 L3 7
8 Watt-hour meters ME Displays and settings imp./ MERLI GERI 10(63)A Cl.2 230Va 50/60Hz 1000 imp./ ME1zr L L ME1, ME1z, ME1zr Single-phase watt-hour meter ➀ Partial or total meter display ➁ Flashing meter indicator ➂ Pushbutton: partial or total meter display, RESET of partial meter (ME1z, ME1zr) ➃ Pulse output for remote metering (ME1zr) ➄ Wiring error indicator imp./ MERLI GERI 10(63)A Cl.2 3x400Va 50/60Hz 100 imp./ ME3zr L1 L1 L2 L2 L3 L ME3, ME3zr Three-phase watt-hour meter without neutral ➀ Partial or total meter display ➁ Flashing meter indicator ➂ Pushbutton: partial or total meter display, RESET of partial meter (ME3zr) ➃ Pulse output for remote metering (ME3zr) imp./ MERLI GERI 10(63)A Cl. 2 3x230/400Va 50/60Hz ME4zr L1 100 imp./ L1 L2 L2 L3 L ME4, ME4zr Three-phase watt-hour meter + neutral ➀ Partial or total meter display ➁ Flashing meter indicator ➂ Pushbutton: partial or total meter display, RESET of partial meter (ME4zr) ➃ Pulse output for remote metering (ME4zr) /x imp./ MERLI GERI x/5a Cl. 2 50/60Hz 3x230/400Va 3x400Va L1 L2 L /x imp./ ME4zrt (L1) (L2) (L3) ME4zrt Three-phase watt-hour meter with or without neutral + CT ➀ Partial or total meter display and CT rating display ➁ Flashing meter indicator ➂ Pushbutton: partial or total meter display, RESET of partial meter, display or selection of CT rating ➃ Pulse output for remote metering. 8
9 0,1imp/ 0,1imp/ 10/ximp/ 10/ximp/ 1imp/ 230Va50/60Hz 10(63)A CL imp/ 100imp/ 100imp/ 10000/ximp/ 10000/ximp/ Watt-hour meters ME Connection diagrams and impulse output data L ME1, ME1z, ME1zr : direct measurement up to 63 A ME1zr L L Impulse contact O for remote metering (ME1zr): 1 impulse of 200 ms per 18 ma (24 V DC) 100 ma (230 V AC). L L1 L2 L3 ME3, ME3zr : direct measurement up to 63 A ME3zr 3x400Va50/60Hz 10(63)A CL L1 L1 L2 L2 L3 L3 Impulse contact O for remote metering (ME3zr): 1 impulse of 200 ms every ma (24 V DC) 100 ma (230 V AC). L1 L2 L3 L1 L2 L3 ME4, ME4zr : direct measurement up to 63 A ME4zr 3x230/400Va50/60Hz 10(63)A CL L1 L1 L2 L2 L3 L3 Impulse contact O for remote metering (ME4zr): 1 impulse of 200 ms every ma (24 V DC) 100 ma (230 V AC). L1 L2 L3 L1 L2 L3 ME4zrt : CT measurement (ratio from 40/5 to 6000/5) three-phase network 3x400V - 50 Hz ME3zrt 3x400Va50/60Hz x/5a CL L1/ L2 L3/ Impulse contact O for remote metering: 10/x impulse of 200 ms per (x = CT rating) = x/10 per impulse, example: CT 500/5 --> 500/10 per impulse = 50 per impulse 18 ma (24 V DC) 100 ma (230 V AC). Warning: do not link the CT secondaries nor connect them to earth L1 L2 L3 ME4zrt 3x230/400Va50/60Hz x/5a CL.2 ME4zrt : CT measurement (ratio from 40/5 to 6000/5) three-phase network 3x230/400V - 50 Hz L1/ L2/ L3/ Impulse contact O for remote metering: 10/x impulse of 200 ms per (x = CT rating) = x/10 per impulse, example: CT 500/5 --> 500/10 per impulse = 50 per impulse 18 ma (24 V DC) 100 ma (230 V AC). Warning: do not link the CT secondaries nor connect them to earth 9
10 Current transformers Measurement and indication Current transformers are for use with watt-hour meters, ammeters and other current sensing devices. Secondary current 5A, ratio Ip / 5 Technical data Secondary current: 5A Maximum voltage rating Ue: 720V Frequency: 50 60Hz Permanent permissible overload: 1.2 In Safety factor - 40 to 4000A primary: Fs<5-5000, 6000A primary: Fs<10 I0 Ambient installation temperature - Standard range: C to 55 0 C - Tropicalised range: C to 60 0 C Relative humidity - Standard range: <95% - Tropicalised range: >95% Standards - Watt-hour meters: BSE61036, IEC61036 (with sealable cover) - Current transformers: BS7626, IEC
11 Current transformers Services and practical advice Current transformer selection Three criteria exist for selecting a CT: 1. The transformation ratio Ip/5 2. The output VA and accuracy class required 3. The physical arrangement 1. The transformation ratio Ip/5 It is recommended that the current transformer primary current selected is the next above the design current of the circuit. e.g. If In = 1390A, select ratio of 1500/5 2. Output VA and accuracy class The accuracy class is a function of the transformer output power and the consumption of the metering circuit. The latter takes the device and cable consumption into account. For a given accuracy class the consumption of the metering circuit must not exceed the power of the current transformer. Cable consumption Secondary circuit Consumption VA per Cable mm 2 route metre at 20 0 C For each temperature rise of 10 0 C the power absorbed by the cables rises by 4% Device consumption Merlin Gerin device Consumption VA Watt-hour meter ME4zrt 0.05 Analogue ammeter 72sq 0.75 Analogue ammeter DI 1.25 Digital ammeter 0.55 Current relay RCI 0.50 Example: consumption of a metering circuit, at 20 0 C Watt-hour meter ME4zrt 0.05VA Digital ammeter 0.55VA 4 metre route length, 2.5mm 2 cable 1.64VA Circuit consumption 2.24VA Required CT ratio is 100/5 From the information given in the table on page 13 it is seen that CT reference will meet class 1 accuracy for this load. 11
12 Current transformers Services and practical advice 3 Current transformer installation All current transformers are suitable for a primary of either cable or busbar. The devices are supplied with fixings to permit mounting on symmetrical DI rail, a flat plate or be fitted to a solid busbar, as detailed in the table below. Secondary terminal covers may be sealed to discourage unauthorised access. Catalogue references DI rail Flat plate Busbar Terminal fixing fixing clamp cover , , Optional (1) , Optional (2) , , (1) Reference (2) Reference Primary connection using copper sleeve The primary connection may be achieved by using a copper sleeve with bolted connections. This generally allows a smaller physical size of CT to be used for a given ratio. Ratios Catalogue references Sleeve reference 40/5 to 200/ , /5 to 600/ , WARIG ever open the secondary circuit of a current transformer whilst the primary circuit is energised. Before any work is performed on the secondary circuit of a current transformer the terminals must be shortcircuited. 12
13 Current transformers Services and practical advice Current transformer aperture mm CT output VA Weight Ratio Cat no. Cat no. circular Maximum busbar Class 0.5 Class 1 Class 3 kg standard tropicalised diameter size 40/ x / x / x / x / x / x x / x x x / x x x / x x x / x x x / x x x 31 or 64 x x / x x 31 or 64 x x / x / x / x x x / x x x / x / x x / x / x / x / x
14 Modular switchgear dimensions Current transformers Catalogue numbers to and to Catalogue numbers to and to Catalogue numbers to and to six Catalogue numbers to and to Catalogue numbers to and to Catalogue numbers to nine Catalogue numbers to Catalogue numbers to Catalogue numbers to Meters ME3, ME4 watt hour meters ME1 watt hour meters Please note: Due to the constant progress in standards and equipment, the characteristics shown in the texts and images are only binding once expressly confirmed by ourselves. 14
15
16 ationwide support on one number - call the Customer Information Centre on Fax Schneider Electric s local support Schneider Electric is committed to supporting its customers at every stage of a project. Our 180 sales engineers, the largest dedicated sales force in the UK electrical industry, operate from 4 customer support centres. Our sales engineers are skilled at assessing individual requirements and combined with the expert support of our product specialists, will develop the most effective and economical answer taking relevant regulations and standards fully into account. To access the expertise of the Schneider Electric group, please call Each customer support centre includes facilities for demonstrations and training, and presentation rooms fully equipped with audio visual and video, providing excellent meeting facilities. Merlin Gerin is a world leader in the manufacture and supply of high, medium and low voltage products for the distribution, protection, control and management of electrical systems. Its quality products, solutions and services are focused on the needs of both the commercial and industrial sectors. Modicon is a world leader in high technology programmable controllers (PLCs) and motion control systems used in industrial automation. Its international catalogue includes PLCs, numerical controllers, terminals, software, multiple fieldbus and ethernet communication networks, and human machine interfaces (HMI). Square D is a total quality organisation and its business is to put electricity to work productively and effectively, protecting people, buildings and equipment. Its low voltage electrical distribution equipment, systems and services are used extensively in residential and commercial applications. Telemecanique is a UK market leader and world expert in industrial control and automation. It provides complete solutions, with its range of components, programmable logic controllers, variable speed drives and communications software. In addition, it offers power distribution through prefabricated busbar trunking. Local customer support centres Scotland Schneider Electric Ltd Unit Academy Business Park Gower Street Glasgow G51 1PR webmastergb@schneider.co.uk South West Schneider Electric Ltd 190 Aztec West Park Avenue Almondsbury Bristol BS32 4TP webmastergb@schneider.co.uk Regional product showrooms orth West Schneider Electric Ltd 8 Brindley Road City Park Business Village Cornbrook Manchester M16 9HQ webmastergb@schneider.co.uk Industrial systems and solutions product showroom Schneider Electric Ltd, University of Warwick Science Park, Sir William Lyons Road, Coventry CV4 7EZ Building systems and solutions product showroom Schneider Electric Ltd, Fordhouse Road, Wolverhampton WV10 9ED Energy and Infrastructure systems and solutions product showroom Schneider Electric Ltd, 123 Jack Lane, Hunslet, Leeds L0 1BS Greater London Schneider Electric Ltd 2nd Floor 408 Strand London WC2R 0E webmastergb@schneider.co.uk MGD JUE 2002
THORNE & DERRICK UK TEL FAX TEL FAX
Rail solutions Powering the Railway Here at Schneider Electric we understand that secure power supplies are essential to the modern railway. That s why making us your supply partner will keep you on the
More informationElectrical contractors solutions brochure
Electrical contractors solutions brochure Welcome to the electrical contractors solutions brochure Schneider Electric s expertise is founded on the skills of its three international brands - Merlin Gerin,
More informationLV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity
LV switch-disconnectors Catalogue Merlin Gerin 40 to 2500 A We do more with electricity LV switch-disconnectors The various low-voltage applications 2 from 40 to 2500 A 4 Compact from 80 to 1250 A 5 Masterpact
More informationRE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC
Characteristics time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC Complementary Product front plate size Control type Housing material Main Range of product Product or component type Electrical
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A
ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat
More informationCT current transformers Ip/5 A ratio
CT current transformers Ip/5 A ratio DB416186.eps Current transformers Ph N Ip Primary circuit The Ip/5A ratio current transformer delivers at the secondary a current (Is) of 0 to 5 A that is proportional
More informationPDL s DBF AND DBS SERIES DISTRIBUTION BOARDS
PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS FEATURES Robust, durable construction Unique double doors open 180 with minimum projection Light grey colour standard, can be painted to suit décor re quirements
More informationECS CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS
Network(s): Summary: ENGINEERING CONSTRUCTION STANDARD ECS 03-0054 CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS EPN, LPN, SPN This standard details the procedures to be undertaken
More informationATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions
to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They
More informationCP Automatic capacitor bank
CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor
More informationTechnical information
Technical information General Regulations WTL current transformers are special transformers which transfer the primary circuits with prescribed accuracy in smaller secondary circuits. Primary and secondary
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationLow Voltage Main Distribution Board
s M series... Low Voltage Main Distribution Board Safe and intelligent power distribution Whether in industrial plants, in infrastructure or in buildings, all technical plant depends on the reliable supply
More informationATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A
Transfer switches Accessories Terminal shrouds IPX protection against direct contact with terminals or connecting parts. Advantages Perforations allow remote thermographic inspection without the need to
More informationNS Feeder pillar up to 3200A
NS Feeder pillar up to 3200A Advanced technology for low voltage, outdoor distribution Merlin Gerin Modicon Telemecanique Outdoor electrical distribution with advanced technology Merlin Gerin low voltage,
More informationRE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW
Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient
More informationADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW
ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years
More informationEquipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module
transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short
More informationZucchini busbar ZUCCHINI DISTRIBUTION FUSE BOARD TAP-OFF
Zucchini busbar ZUCCHINI DISTRIBUTION FUSE BOARD TAP-OFF Global strength built on local knowledge Legrand is the global specialist in electrical and digital building infrastructures. Innovation is the
More informationPHOENIX CONTACT
Current transformers INTERFACE Data sheet 03359_en_03 PHOENIX CONTACT 20-04-04 Description The PACT Analog current transformers form a complete range of bus-bar, plug-in and winding current transformers
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationLA Motor Protection. A South African Company to be Proud of
LA Motor Protection Relay Physical Address: 298 Soutter Street, Pretoria West Tel: 083 454 6949, +27 12 327 1729 Fax: +27 (0)12 327 1733 Toll Assist: 0860 10 30 41 www.newelec.co.za sales@newelec.co.za
More informationInstallation & User Instructions
Installation & User Instructions 16/25A Digital Dimmer (416/425) INTRODUCTION The 416 and 425 are Digital Dimmers capable of dimming a single channel with total loads of up to 16A and 25A respectively.
More informationCPG.0 Single busbar gas-insulated cubicles
MV Switchgear Primary Distribution CPG.0 Single busbar gas-insulated cubicles Up to 36 kv CPG System The quality of products designed, manufactured and installed by Ormazabal is underpinned by the implementation
More informationBulletin 825 SMM Smart Motor Manager
Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.
More informationschneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.
K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles
More informationPQstorI One stop solution for energy storage and power quality
ENERGY STORAGE INVERTERS PQstorI One stop solution for energy storage and power quality s.a. ABB n.v. Power Quality Products Allée Centrale 10 Z.I. Jumet B-6040 Charleroi (Jumet) Belgium Phone: +32(0)
More informationDomae. The right solution for distribution boards
Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:
More informationCOMPLETE SOLUTIONS FOR POWER PROTECTION
COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX
More informationRE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC
Characteristics time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC Main Range of product Product or component type Electrical connection Discrete output type Contacts type and composition
More informationBurden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM
Contents Section Page 1.0 Introduction 1 2.0 Specification 1-4 3.0 Installation 5-8 4.0 Programming 9-10 5.0 Menus 10-12 6.0 Fault Finding/Diagnostics 12-13 7.0 Communication 13 8.0 Setting Up 13-16 1.0
More informationDifferential pressure sensor
s 1 916 QBM3x20-.. QBM3x20-..D Differential pressure sensor for air and non-aggressive gases QBM3020-.. QBM3120-.. High degree of measuring accuracy Adjustable characteristic curve (pressure-linear or
More informationIntelligent Choice for Prestigious Buildings
Intelligent Choice for Prestigious Buildings Table of Contents I-LINE Moulded Case Circuit Breakers General Characteristics 16A to 160A 125A to 250A 250A to 600A 300A to 800A 630A to 1250A 2/3 4 5 6 6
More informationINTELLIGENT MEDIUM POWERBAR
INTELLIGENT MEDIUM POWERBAR POWERBAR INTRODUCTION TECHNICAL FEATURES Intelligent Medium Powerbar is a patented range of busbar trunking that is utilized within Data Centers and various industrial applications
More informationAEL.TF.32 INTRODUCTORY AND OPERATING MANUAL THREE-PHASE ACTIVE ELECTRONIC ELECTRICITY METERS
AEL.TF.32 INTRODUCTORY AND OPERATING MANUAL THREE-PHASE ACTIVE ELECTRONIC ELECTRICITY METERS 0 122 CONTENTS Part Name Page No 0. Introduction 1 1. Introduction Technical Specifications of the Electricity
More informationProtection components
Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed
More informationValid for you. medium voltage switchgear
Valid for you. medium voltage switchgear VEO knows your needs VEO s field of expertise is energy. We provide customised automation and electrification solutions for customers in the power generation, distribution
More informationInstallation Manual for DC Injection Brake Units
Power Drive Services INJ Series DC brake modules PDS 11-30-100A Page 1 of 17 Issue 15 Contents. 1. Safety. 2. Installation. 3. Setting Up. 4. Wiring Diagrams. 5. Specifications. 6. Selection. 7. Timing
More informationTime scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)
86 Timer modules 86 Timer modules for use in conjunction with relay & socket. 86.00T - Multi-function & multi-voltage timer module 86.30T - Bi-function & multi-voltage timer module Complies with EN 45545-2:2013
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationPower Supplies & Transformers Phaseo Bring energy to your automated systems!
Power Supplies & Transformers Phaseo Bring energy to your automated systems! Simply Smart! Leveraging ingenuity and intelligence for ease of use Power Supplies Universal range single/three-phase 100-500
More informationCPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards
Medium Voltage Switchgear Primary Distribution CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka General description Presentation Ormazabal s CPG System includes the CPG.1
More informationGet smart. Reduce energy consumption
MEM Electrical sub-distribution Lighting and power metering solutions L2 building regulations compliant Single phase MCB boards Three phase MCB boards MCCB panelboards Get smart. Reduce energy consumption
More informationTECHNICAL SPECIFICATIONS DESCRIPTION: - CENTAC COMPRESSOR 2
TECHNICAL SPECIFICATIONS DESCRIPTION: - CENTAC COMPRESSOR 2 Description: The Centac 2 compressor is a multi-stage (3-stage) centrifugal air compressor. It has an output of approx 5000 to 6000 m 3 /hr (actual
More informationElectrification Products United Kingdom. Buildings & Infrastructure Enhanced energy efficiency & performance
Electrification Products United Kingdom Buildings & Infrastructure Enhanced energy efficiency & performance About ABB Let s write the future together ABB is a pioneering technology leader that works closely
More informationTRANSMISSION SYSTEMS
TRANSMISSION SYSTEMS Transmitting large amounts of electric energy over long distances is accomplished most efficiently by using high-voltages. Without transformers the widespread distribution of electric
More informationRelax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.
Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE Distributor : LEGRAND ELECTRIC LIMITED Great King Street North, Birmingham, B19 2LF Tel : 0870 608 9000 Fax : 0870 608 9004 CONSUMER UNIT BRO.10.05.??K
More informationNew DX 3 High rating & breaking capacity
New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand
More informationJANDS DD-8. Technical Manual. Version 1.0
JANDS DD-8 O p t o - I s o l a t e d D M X S p l i t t e r Technical Manual Version 1.0 EMC COMPLIANCE This product is approved for use in Europe and Australia/New Zealand and conforms to the following
More informationELECTRICIANS REGULATIONS EXAMINATION 25 June 2011
ER42 Candidate Code No. For Board Use Only Result Date Result Date Int ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011 Int QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage
Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144
More informationWhad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF
Manuel d installation Installation manual Part. LE05733AA-07/12-01 GF Index 1 Introduction 18 2 Conditions for use 19 3 Installation 20 4 Visual and acoustic warning signals 22 5 ups diagnostic software
More informationInvestigation into UK socket-outlets incorporating USB charging points
Investigation into UK socket-outlets incorporating USB charging points Electrical Safety First investigated a number of commercially available UK socket-outlets incorporating USB ports, as a repeat of
More informationOPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,
More informationAn electrical panel capable of evolving
An electrical panel capable of evolving Prisma TT Low voltage factory built assemblies Buildings Commercial & Industrial Make the most of your energy General For a dependable electrical installation Total
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More informationATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A
TyS t M - TyS g M utomatic Transfer Switching Equipment Transfer switches new The solution for > High Rise uildings > Data centre > Healthcare buildings TyS g M I-0-II P atys-mg_001_b_1_cat Function TyS
More informationContactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload
According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor
More informationMCD 200 Series Soft Starters
MCD 200 Series Soft Starters AC motors often cause one or more serious problems during startup acceleration. MCD 200 Series electronic soft starters control motor current to provide a smooth start. When
More informationEMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT
Product description One-LED Solo TM is a non-maintained, self-contained LED emergency luminaire comprising an Omni-LED emergency LED driver, hinged rechargable battery and a flush-mount SELV lamp head.
More informationExpert Design...Trusted Power
Expert Design...Trusted Power 350 750 kva Range Performance I Durability I Serviceability A new power standard has arrived. The 350 750 kva range from FG Wilson is designed by our expert engineers to
More informationLCU DX Efficient cooling with no loss of space
LCU DX Efficient cooling with no loss of space 2 Cooling for network and server enclosures Space-saving installation of the internal unit between the 482.6 mm (19 ) level and side panel Optimum support
More informationALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications
$ PROGRAMMABLE POWER SUPPLY EAN CODE : 3760244880062 1 output Powerfull POWERFUL ALR3220 VISUAL : Large graphic display SOFT-TOUCH : Sensitiv keypad CONNECTED : USB, RS232, RS485 & 0-10V isolated LabVIEW
More informationVariable Frequency Drive NEW! Moving your Control. Forward VFD from Unitronics kW Single Phase kW Three Phase
Variable Frequency Drive Moving your Control NEW! Forward VFD from Unitronics 0.4-2.2kW Single Phase 0.75-110kW Three Phase Total Solution All-in-One software PLC programming HMI design NEW! VFD configuration
More informationSingle-phase CT current transformers Cat. Nos :
Index Pages 1. Description - Use... 2 2. Range...2 3. Overall dimensions...2 4. Preparation - Connection... 3 5. General characteristics...5 6. Compliance and approvals...7 1/6 1. DESCRIPTION - USE Closed-type
More informationMotorised and automatic transfer enclosed switchess
s Integrated products and solutions coff_538_a.eps atysm_251_b_1_cat.eps The solution for > igh-rise buildings > Data centers > Energy generation > ealthcare buildings > Banks and insurance companies >
More informationMotor management system TeSys T Give your motor starters a sixth sense!
The efficiency of Telemecanique branded solutions Used in combination, Telemecanique products provide quality solutions, meeting all your Automation & Control applications requirements. Motor management
More informationTechnical Data Sheet Sigma Series DE Meter
Technical Data Sheet Sigma Series DE Meter The moving iron panel meters, DE 48/72/96/144 are housed in a moulded polycarbonate cases which are suitable for the measurement of AC currents for frequency
More informationDMX 3 -I 2500 switch disconnectors
8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40
More informationElectrical distribution and safety for homes Catalogue SquareD Consumer units and protection devices
Electrical distribution and safety for homes Catalogue 2013 SquareD Consumer units and protection devices SquareD EL Elegance and safety in perfect harmony 2 Innovation in residential switchboards Attractive
More informationRated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits
7 Technical Data Dielectric strength Circuit Withstand voltage (at 50/60 Hz) Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control
More informationCME1-4 A-R-I-E-AQQE S-A-D-N
GRUNDFOS DATA BOOKLET CME1-4 A-R-I-E-AQQE S-A-D-N Grundfos Pump 98394868 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmebasis/98394868/cme1-4-a-r-i-e-aqqe.html
More informationSeries Motor Protection
320-327 Series Motor Protection Relay Physical Address: 298 Soutter Street, Pretoria West Tel: 083 454 6949, +27 12 327 1729 Fax: +27 (0)12 327 1733 Toll Assist: 0860 10 30 41 www.newelec.co.za sales@newelec.co.za
More informationInstructions for the BCEA Rotary heat exchanger
Instructions for the Rotary heat exchanger 1. General The heat recovery section is a rotary heat exchanger with high temperature and humidification efficiencies. The heat exchanger operates with an efficiency
More informationPowerLogic High Density Metering System 4-Meter Enclosure Installation Guide
PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment
More informationSION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG
Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.02 2011 Answers for energy. R-HG11-172.tif 2 Siemens HG 11.02 2011 Contents SION Vacuum Circuit-Breakers Medium-Voltage Equipment Catalog
More informationsinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004
Variable Speed Drives 0.12 kw to 3 kw Short Form 2004 sinamics SINAMICS Variable Speed Drives 0.12kW to 3kW Product Information Pricing The is a Variable Speed Drive with basic functions for a variety
More informationELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010
Candidate Code No. Result Date Int For Board Use Only ER38 Version of AS/NZS 3000 used (tick ONE Box) 2000 2007 & Amend 1 ELECTRICIAN S REGULATIONS EXAMINATION 26 June 2010 QUESTION AND ANSWER BOOKLET
More informationInstallation & Operating Instructions
Underfloor Heating Controller Cat. No TPT1 Installation & Operating Instructions Installation & Operating Instructions Main unit (front view) Slots for snap-on bezel Indicator light shows green when mains
More informationVD4/R. Medium Voltage vacuum circuit-breakers for secondary distribution
VD4/R Medium Voltage vacuum circuit-breakers for secondary distribution DESCRIPTION CIRCUIT-BREAKER SELECTION AND ORDERING SPECIFIC PRODUCT CHARACTERISTICS OVERALL DIMENSIONS ELECTRIC CIRCUIT DIAGRAM
More informationNEW TX³ RANGE PROTECTION YOU CAN RELY ON
TX³ NEW RANGE TRUSTED PROTECTION FOR YOUR INSTALLATIONS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW TX³ RANGE PROTECTION YOU CAN RELY ON Designed to meet the requirements of
More informationELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours
Candidate Code No. IT 32 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSPECTOR EXAMINATION 14 November 2015 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours INSTRUCTIONS READ CAREFULLY
More informationSafety Sensor CSS 180 Product Information
Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 CSS180CSS 180 PDF-M / EN 60947-5-3 EN 954-1 Control Category 4 IEC 61508, suitable for use in SIL 3 applications BG Type-Certification in
More informationEMPAC Metal enclosed capacitor bank for wind applications
EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks
More informationProduct Overview. Product Identification. Amps One CT Two CTs Three CTs
AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable
More informationGROUP TP&N DISTRIBUTION BOARD TYPE B. Distribution boards for modern commercial & industrial installations
TP&N DISTRIBUTION BOARD TYPE B Distribution boards for modern commercial & industrial installations TP&N DISTRIBUTION BOARD - TYPE B Designed & Engineered in the UK Compliant to BS EN 61439-3:2012 Supplied
More information013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS
013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification
More informationHIGH POWER RECTIFIER SYSTEMS
HIGH POWER RECTIFIER SYSTEMS STATE OF THE ART DESIGN AND ENGINEERING Dynapower Company is the world s largest independent manufacturer of High Power Rectifier Systems. We design, manufacture and test integrated
More information(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2
Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.
More information2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4
CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power
More informationInstallation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue
FAQs I have installed the ATS panel but it won t go into the mains supply? First check all cables are in place and properly installed and that the control fuses (A-C on page 4) have not blown. If it still
More informationCI-TI Contactors and Motor Starters Type CI 6-50
Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components
More informationOutdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications
Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers
More informationPROCUREMENT SPECIFICATION DELTA MODEL DSC900 TRANSPORTABLE CRASH CERTIFIED RISING PLATE BARRIER SYSTEM
PROCUREMENT SPECIFICATION DELTA MODEL DSC900 TRANSPORTABLE CRASH CERTIFIED RISING PLATE BARRIER SYSTEM SYNOPSIS This Procurement Specification defines a CRASH CERTIFIED - TRANSPORTABLE BARRIER SYSTEM -
More informationMODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A
MODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A MODE - Multiple Occupancy Distribution Equipment Contents 4 MODE range: introduction 5 MODE
More informationAuxiliary Relay (7PJ11) and Trip Relay (7PJ12)
s www.siemens.com/energy Auxiliary Relay (7PJ) and Trip Relay (7PJ2) Better protection and more efficiency for your power system Answers for infrastructure and cities. Auxiliary Relay and Trip Relay Catalogue
More informationGSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3
GSL30D Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3 Power Rating Standby power LTP kva 32.50 Standby power LTP kw 26.00 Prime power PRP kva 30.50 Prime power
More informationTotally Integrated Power. A reliable all-rounder. Gas-insulated medium-voltage switchgear 8DJH 36.
Totally Integrated Power A reliable all-rounder Gas-insulated medium-voltage switchgear 8DJH 36 www.siemens.com/8djh36 Totally Integrated Power (TIP) We bring power to the point Left: Munich is one of
More information