Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

Size: px
Start display at page:

Download "Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R"

Transcription

1 Safety Switches Heavy Duty 240 Volt Indoor Type Outdoor Type 3R Horsepower Ratings 240V AC Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* 2 Wire 4 Wire 3 Wire System Rating Number Price Std. Pkg. Number Price Std. Pkg. Std. Max. Std. Max. Std. Max. 250 Volt DC 240 Volt Fusible 2-Pole, 2-Fuse, and Solid Neutral (Also used for 2-Pole, 2-Wire Applications) 240 Volt AC/250 Volt DC 0030 HFC22N - 02 HFC22NR HFC222N - 08 HFC222NR HFC223N HFC223NR HFC224N HFC224NR HFC225NH - 29 HFC225NRH HFC225N - 53 HFC225NR HFC226NH - 33 HFC226NRH HFC226N - 55 HFC226NR HFC227N HFC227NR HFC228N HFC228NR Pole, 3-Fuse, and Solid Neutral (Also used for 3-Pole, 3-Wire Applications) 240 Volt AC/250 Volt DC 240 Volt Fusible 0030 HFC32N - 04 HFC32NR HFC322N - 09 HFC322NR HFC323N HFC323NR HFC324N HFC324NR HFC325NH - 37 HFC325NRH HFC325N - 58 HFC325NR HFC326NH - 39 HFC326NRH HFC326N - 6 HFC326NR HFC327N HFC327NR HFC328N HFC328NR Pole, 2-Fuse Type 4/4X Stainless Type 2 Industrial 240 Volt AC/250 Volt DC 0030 HFC22S - 03 HFC22J HFC222S - 09 HFC222J HFC223S HFC223J HFC224S HFC224J Pole, 3-Fuse (Also used for 2-Pole, 2-Wire Applications in A Ratings) 240 Volt AC/250 Volt DC 0030 HFC32S - 04 HFC32J HFC322S HFC322J HFC323S HFC323J HFC324S HFC324J HFC325S - 54 HFC325J HFC326S - 57 HFC326J HFC327S HFC327J * In pounds (lbs). Height reduced switch (45.25 rather than 56 inches in height) for use with 500MCM or smaller conductors. /8 Dual horsepower ratings: Std.- applies when non-time delay fuses are installed. Max.- applies when timedelay fuses are installed. These switches are UL-listed for application on grounded B-phase systems and are suitable for 3-phase motor applications. When a neutral is required use a field installed neutral kit. Suitable for use as service entrance equipment. Also rated Type 3S/3R. Please contact factory for availability.

2 Safety Switches Heavy Duty 600 Volt Horsepower Ratings Indoor Type Outdoor Type 3R 480V AC 600V AC Phase, 3 Phase, Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* 2 Wire 3 Wire 2 Wire 3 Wire Volt Volt System Rating Number Price Std. Pkg. Number Price Std. Pkg. Std. Max. Std. Max. Std. Max. Std. Max. DC DC 600 Volt Fusible 2-Pole, 2-Fuse 3-Pole, 3-Fuse 480 Volt AC/600 Volt AC/600 Volt DC 0030 HFC26-05 HFC26R HFC HFC262R HFC HFC263R HFC HFC265R HFC HFC266R Volt Fusible (For 2-Pole Applications use outside poles of 3-Pole Switches) 2-Pole, 2-Fuse 480 Volt AC/600 Volt AC/250 Volt DC 0030 HFC36-04 HFC36R HFC HFC362R HFC HFC363R HFC HFC364R HFC365H - 36 HFC365RH HFC HFC365R HFC366H - 38 HFC366RH HFC HFC366R HFC HFC367R HFC HFC368R Pole, 3-Fuse and Solid Neutral 3-Pole, 3-Fuse 480 Volt AC/600 Volt AC/250 Volt DC 0030 HFC36N - 04 HFC36NR HFC362N - 09 HFC362NR HFC363N HFC363NR HFC364N HFC364NR HFC365N - 58 HFC365NR HFC366N - 6 HFC366NR HFC367N HFC367NR HFC368N HFC368NR Volt AC/600 Volt AC/600 Volt DC Type 4/4X Stainless Type 2 Industrial 0030 HFC26S - 05 HFC26J HFC262S HFC262J HFC263S HFC263J HFC265S - 53 HFC265J HFC266S - 56 HFC266J Volt AC/600 Volt AC/250 Volt DC 0030 HFC36S - 03 HFC36J HFC362S HFC362J HFC363S HFC363J HFC364S HFC364J HFC365S - 58 HFC365J HFC366S - 6 HFC366J HFC367S HFC367J HFC368S HFC368J * In pounds (lbs) A 3-Pole switches are also rated 600V DC. Height reduced switch (45.25 rather than 56 inches in height) for use with 500MCM or smaller conductors. Use 3-Pole switch for 200A applications. Dual horsepower ratings: Std.- applies when non-time delay fuses are installed. Max.- applies when timedelay fuses are installed. Suitable for use as service entrance equipment. Also rated Type 3S/3R. Please contact factory for availability. /9

3 Safety Switches Heavy Duty 600 Volt Indoor - Type Outdoor - Type 3R Horsepower Ratings 240 Volt 480 Volt 600 Volt 250V 600V Ampere Catalog Ship. List Catalog Ship. List System Rating Number Wgt. Price Number Wgt. Price -Phase 3-Phase -Phase 3-Phase -Phase 3-Phase DC DC 600 Volt Non-Fusible 2-Pole ➂ 480 Volt AC / 600 Volt AC / 600 Volt DC 3-Pole 30 HNFC HNFC26R 3-7 / HNFC HNFC262R HNFC HNFC263R HNFC HNFC265R HNFC266 - HNFC266R Volt AC / 600 Volt AC / 250 Volt DC 30 HNFC HNFC36R / HNFC362H - HNFC362RH HNFC HNFC362R HNFC HNFC363R HNFC HNFC364R HNFC HNFC365R HNFC HNFC366R HNFC HNFC367R HNFC HNFC368R Volt Non-Fusible 2-Pole 480 Volt AC / 600 Volt AC / 600 Volt DC Type 4 / 4X Stainless Type 2 Industrial 30 HNFC26S 3 - HNFC26J 3-7 / HNFC262S 20 - HNFC262J HNFC263S 25 - HNFC263J HNFC265S 3 - HNFC265J HNFC266S 5 - HNFC266J Pole 480 Volt AC / 600 Volt AC / 250 Volt DC 30 HNFC36S 3 - HNFC36J / HNFC362SH 5 - HNFC362JH HNFC362S 9 - HNFC362J HNFC363S 24 - HNFC363J HNFC364S 47 - HNFC364J HNFC365S 8 - HNFC365J HNFC366S 20 - HNFC366J HNFC367S HNFC367J HNFC368J Also rated 600V DC. /20 Compact switch (. H, 6.6 W box less cover and handle). Short circuit withstand rating 00,000 RMS sym. amps. Use 3-Pole switch for 200A application. Suitable for use as service entrance equipment. Also rated type 3S / 3R. Please contact factory for availability.

4 Type 4/4X & 2 with Viewing Window Description A, 3-pole 600V max. in fusible and non-fusible versions in Type 4/4X stainless steel and Type 2 enclosures. All allow viewing of visible blade position A also allow viewing of indicating type fuses. Features b Rugged installer-friendly enclosure design features a gasket flange with continuously welded seams. b Tool-free cover latches. b Two, three and four point mounting. b Metal handle with large insulating grip features a positive stop in both ON and OFF position. b Ground lugs provided as standard. b Type 2 enclosures are fabricated from galvanized steel and are also rated for 3R/3S outdoor applications. b Type 4X stainless steel switches (30-200A) are provided with stainless steel interior parts. b The widest range of accessories available including 200% neutrals, gold plated PLC auxiliary contacts and isolated ground kits. Maximum Horsepower Ratings c Ampere Catalog List Ship. 240V AC 480V AC 600V AC 250V 600V System Rating Number Price $ Weight a Phase, 2 Wire 3 Phase, 3 Wire 3 Phase, 3 Wire 3-Phase, 3 Wire DC DC 3-Pole, 3 Wire Fusible, Type 2 de 600 Volt AC / 250 Volt DC b 30 HFC36JW / HFC362JW f 00 HFC363JW f 200 HFC364JW HFC365JW HFC366JW Pole, 3 Wire Non-Fusible, Type 2 de 600 Volt AC / 250 Volt DC b 30 HNFC36JW HNFC362JW f 00 HNFC363JW f 200 HNFC364JW HNFC365JW Pole, 3 Wire Fusible, Type 4X Stainless Steel e 600 Volt AC / 250 Volt DC b 30 HFC36SW / HFC362SW f 00 HFC363SW f 200 HFC364SW HFC365SW Pole, 3 Wire Non-Fusible, Type 4X Stainless Steel e 600 Volt AC / 250 Volt DC b 30 HNFC36SW HNFC362SW f 00 HNFC363SW f 200 HNFC364SW HNFC365SW a In pounds (lbs). b 200A switches are also rated 600V DC. c Maximum HP ratings listed apply only when time delay fuses are used. d Also rated 3S/3R for outdoor use. e All switches are suitable for use as service entrance equipment. Use outside poles of 3-pole switch for 2-pole application. f 600V DC and 600V DC horsepower rating shown requires (2) poles to be connected in series. /2

5 Type VBII 4 & 6 Pole Heavy Duty Safety Switches Application 4 & 6 pole Switches are commonly used as a disconnecting means for twospeed, two-winding motors. Fused switches provide both over current and short circuit protection. Non-fusible switches normally provide a local disconnection means for twospeed motors which are remote from their motor controller. 4 pole switches are also used in 3-phase, 4-wire circuits when a switching neutral is required. All 4 & 6 pole switches are service entrance rated. Description 4 & 6 pole switches are available in A ratings and in both fusible and non-fusible versions. 4-pole switches are supplied with either Type or Type2/3R enclosures. 6-pole switches are available with either Type 2/3R or Type 4X stainless steel enclosures. Standards b UL & CUL listed under file #E4776 b Meets UL98 for enclosed switches b 4 & 6 Pole switches are suitable for use as service entrance b Meets NEMA Standard KS- for enclosed switches b Meets NEC wire bending space requirements Features b Visible blade, double break switching action b Highly visible ON/OFF indication b Defeatable dual cover interlock b Padlock option in OFF position b All copper current carrying parts a b Tangenital knockouts (Type, 4-pole switches) HNF663S 4 Pole Type VBII Switches b Indoor Type Type 2/3R Industrial Horsepower Ratingsc Amp Catalog List Ship Wt. Catalog List Ship Wt. 240V, 2, 4W 240V 3 480V, 3 600V, 3 250V System Rating Number Price $ (lbs.) Number Price $ (lbs.) Std. Max. Std. Max. Std. Max. Std. Max. DC Fusible 600 Volt AC, 250 Volt DC 4 Pole, 4 Fuse d 30 HF46 36 HF46J / / HF HF462J 40 7 / / HF HF463J HF HF464J Non-fusible 600 Volt AC, 250 Volt DC 4 Pole 30 HNF46 32 HNF46J HNF HNF462J HNF HNF463J HNF HNF464J Pole Type VBII Switches b Type 2/3R Industrial Type 4X Stainless Steel Horsepower Ratingsc Amp Catalog List Ship Wt. Catalog List Ship Wt. 240V 3 480V, 3 600V, 3 250V System Rating Number Price $ (lbs.) Number Price $ (lbs.) Std. Max. Std. Max. Std. Max. DC Fusible 600 Volt AC, 250 Volt DC 6 Pole, 6 Fuse d 30 HF66J 37 HF66S / / HF662J 4 HF662S 4 7 / HF663J 44 HF663S HF664J 90 HF664S Non-fusible 600 Volt AC, 250 Volt DC 6 Pole 30 HNF66J 33 HNF66S HNF662J 35 HNF662S HNF663J 37 HNF663S HNF664J 80 HNF664S a Lugs are aluminum alloy as standard. Optional copper body lugs are available. b All 4 & 6 pole VBII switches are suitable for use as service equipment when a neutral is installed or equipment ground kit is properly connected. /22 c Dual horsepower ratings: Std. applies when non-time-delay fuses are installed. Max. applies when time delay fuses are installed. d Fusible switches accept Class H Fuses as the standard. Class R & J fuses can also be installed and increase the rating from 0,000 to 200,000 AIC. For Class J, the load base is moved upward. For Class R fuses, rejection kits are required.

6 Safety Switch Dimensions (Inches)* & Shipping Weights Safety Switch Dimensions (Inches)* & Shipping Weights Height Width Depth With With With With Knockout Shipping Catalog Box Door Rain Shed Box Handle Box Handle Diagram a Weight Number A b C D E F G (lbs.) HFC22J HFC22N S6 2 HFC22NR S8 3 HFC22S HFC222J HFC222N S6 8 HFC222NR S7 9 HFC222S HFC223J HFC223N S0 23 HFC223NR S 24 * For inches / millimeters conversion, multiply inches by a Knocks not provided on Type 4 / 4X and 2 or in 800 & 200A switches. /23

7 Safety Switch Dimensions (Inches)* & Shipping Weights Height Width Depth With With With With Knockout Shipping Catalog Box Door Rain Shed Box Handle Box Handle Diagram Weight Number A b C D E F G a (lbs.) HFC223S HFC224J HFC224N S2 47 HFC224NR S3 48 HFC224S HFC225N S4 53 HFC225NH S4 29 HFC225NR S5 62 HFC225NRH S5 3 HFC226N S4 55 HFC226NH S4 33 HFC226NR S5 59 HFC226NRH S5 35 HFC227N HFC227NR HFC228N HFC228NR HFC S4 49 HFC265J HFC265R S5 52 HFC265S HFC S4 55 HFC266J HFC266R S5 55 HFC266S HFC32J HFC32N S6 4 HFC32NR S8 5 HFC32S HFC322J HFC322N S6 9 HFC322NR S7 20 HFC322S HFC323J HFC323N S0 25 HFC323NR S 26 HFC323S HFC324J HFC324N S2 49 HFC324NR S3 50 HFC324S HFC325J HFC325N S4 58 HFC325NH S4 37 HFC325NR S5 62 HFC325NRH S5 38 HFC325S HFC326J HFC326N S4 6 HFC326NH S4 39 HFC326NR S5 65 HFC326NRH S5 42 HFC326S HFC327J HFC327N HFC327NR HFC327S HFC328N HFC328NR HFC S6 4 HFC36J, JW HFC36L S6 9 HFC36N S6 4 HFC36NR S8 5 HFC36R S8 5 HFC36RL S7 20 HFC36S, SW HFC S6 9 * For inches / millimeters conversion, multiply inches by a Knocks not provided on Type 4 / 4X and 2 or in 800 & 200A switches. /24

8 Safety Switch Dimensions (Inches)* & Shipping Weights Height Width Depth With With With With Knockout Shipping Catalog Box Door Rain Shed Box Handle Box Handle Diagram Weight Number A b C D E F G a (lbs.) HFC362J, JW HFC362N S6 9 HFC362NR S7 20 HFC362R S7 20 HFC362RL S 25 HFC362S, SW HFC S0 24 HFC363J, JW HFC363N S0 25 HFC363NR S 26 HFC363R S 25 HFC363S HFC S2 48 HFC364J, JW HFC364N S2 49 HFC364NR S3 48 HFC364R S3 49 HFC364S, SW HFC S4 54 HFC365H S4 36 HFC365J, JW HFC365N S4 58 HFC365NR S5 62 HFC365R S5 57 HFC365RH S5 37 HFC365S, SW HFC S4 57 HFC366H S4 38 HFC366J, JW HFC366N S4 6 HFC366NR S5 65 HFC366R S5 6 HFC366RH S5 4 HFC366S HFC HFC367J HFC367N HFC367NR HFC367R HFC367S HFC368, J, S HFC368N HFC368NR HFC368R HNFC S4 09 HNFC265J HNFC265R S5 8 HNFC265S HNFC S4 HNFC266J HNFC266R S5 20 HNFC266S HNFC S7 2 HNFC36J, JW HNFC36R S9 3 HNFC36RL S7 20 HNFC36S, SW HNFC S6 8 HNFC362J, JW HNFC362R S7 9 HNFC362RL S 24 HNFC362S, SW HNFC S0 23 HNFC363J, JW HNFC363R S 24 HNFC363S, SW HNFC S2 46 HNFC364J, JW HNFC364R S3 47 HNFC364S, SW * For inches / millimeters conversion, multiply inches by a Knocks not provided on Type 4 / 4X and 2 or in 800 & 200A switches. /25

9 A A A A Heavy Duty Safety Switches Safety Switch Dimensions (Inches)* & Shipping Weights Dimensions Height Width Depth With With With With Knockout Shipping Catalog Box Door Rain Shed Box Handle Box Handle Diagram Weight Number A b C D E F G a (lbs.) HNFC S4 4 HNFC365J, JW HNFC365R S5 8 HNFC365S, SW HNFC S4 6 HNFC366J, S HNFC366R S5 20 HNFC367, J HNFC367R HNFC367S HNFC368, J HNFC368R Type or 3R A HD Type VBII Type 4/4X or A HD Type VBII E G E G B or C B or C D F D F Type or 3R A Type VBII (HD) Type 4/4X or A HD Type VBII E G E G B or C B or C D F D F * For inches / millimeters conversion, multiply inches by A switches. a Knocks not provided on Type 4 / 4X and 2 or in 800 & /26

10 knockout diagrams Type & 3R Enclosures Removable plate covering HA Type Hub opening (Max..25 Conduit) S 4 K.O.'s for Conduit in. 7 K.O.'s for Conduit in. Embossed.25 in. mounting holes (4 places) S2 Embossed.25 in. mounting holes (4 places) 2 K.O.'s for Conduit in. 0 K.O.'s for Conduit in. S3 Embossed.25 in. mounting holes (3 places) 2 K.O.'s for Conduit in. 3 K.O.'s for Conduit in. Removable plate covering HA Type Hub opening (Max..25 Conduit) 0 K.O.'s For Conduit 0.50, 0.75, in. 4 K.O.'s for Conduit 0.75, in. S4 Embossed.25 in. mounting holes (3 places) S5 Embossed.25 in. mounting holes (3 places) S6 8 K.O.'s for Conduit 0.50, 0.75, in. 2 K.O.'s for Conduit in. 4 K.O.'s for Conduit in. 4 K.O.'s for Conduit 0.75, in. Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) 2 K.O.'s for Conduit in. 3 K.O.'s for Conduit in dia. K.O's Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S7 S8 S dia. K.O's 0.25 dia. K.O. 2 K.O.'s for Conduit 0.75, in. 5 K.O.'s for Conduit 0.50, 0.75, in dia. K.O. 2 K.O.'s for Conduit 0.75, in. 5 K.O.'s for Conduit 0.50, 0.75, in. Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S0 S S dia. K.O dia. K.O. 4 K.O.'s for Conduit 0.75,,.25,.50 in. 0 K.O.'s for Conduit,.25,.50, 2 in. 2 K.O.'s for Conduit 0.75,,.25,.50 in dia. K.O dia. K.O. 5 K.O.'s for Conduit,.25,.50, 2 in dia. K.O dia. K.O. 4 K.O.'s for Conduit.25,.50, 2.00, 2.50 in. * For inches / millimeters conversion, multiply inches by /27

11 knockout Diagrams Type & 3R Enclosures Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S3 S4 S5, 0.25, dia. K.O 7 K.O.'s for Conduit.25,.50, 2.00, 2.50 in dia K.O. 8 K.O.'s for Conduit 2.00, 2.50, 3.00, 3.50 in , 0.75 dia. K.O.'s 4 K.O.'s for Conduit 2.00, 2.50, 3.00, 3.50 in , 0.75 dia. K.O.'s Removable plate covering HS Type Hub opening (Max. 2.5 Conduit) S6 S dia. K.O dia. K.O. 4 K.O.'s for Conduit 0.50, 0.75,,.25 in dia. K.O. 7 K.O.'s for Conduit 0.50, 0.75,,.25 in dia. K.O. * For inches / millimeters conversion, multiply inches by /28

12 Special Applications Safety Switches Dimension Drawings selections 4-Pole & 6-Pole 4 & 6 Pole Safety Switch Dimensions Inches (mm) Catalog Enclosure M mounting Number A B C D E F Figure, 4-Pole Fusible and Non-fusible, Type HNF (622) 9.53 (242) 6.09 (55) 9.00 (483) 6.75 (7) (7) HF (740) 9.53 (242) 6.09 (55) (597) 6.75 (7) (7) HNF (632).50 (292) 6.09 (55) 9.00 (483) 9.38 (238) (7) HF (852).50 (292) 6.09 (55) (699) 9.38 (238) (7) HNF (702) 2.8 (309) 6.09 (55) 9.36 (492) 8.00 (203) (7) HF (926) 2.8 (309) 6.09 (55) 28. (74) 8.00 (203) (7) HNF (94) 9.2 (486) 6.42 (63) (784) 5.00 (38) 0.44 () HF (257) 9.2 (486) 6.42 (63) (30) 5.00 (38) 0.44 () Figure 2, 4 & 6 Pole Fusible Type 2/3R and 4X HF46J, HF66J, (622) 9.53 (242) 6.48 (65) 3.65 (804) 5.47 (39) 0.27 (7) HF66S HF462J, HF662J, (852).50 (292) 6.48 (65) (907) 8.00 (203) 0.27 (7) HF662S HF463J, HF663J, (926) 2.8 (309) 6.48 (65) (982) 8.47 (25) 0.27 (7) HF663S HF464J, HF664J, (257) 9.2 (486) 6.78 (72) 5.64 (32) 3.44 (34) 0.33 (8) HF664S Figure 2, 4 & 6 Pole Non-fusible Type 2/3R and 4X HNF46J, HNF66J, (622) 9.53 (242) 6.48 (65) (667) 5.47 (39) 0.27 (7) HNF66S HNF462J, HNF662J, (632).50 (292) 6.48 (65) (687) 8.00 (203) 0.27 (7) HNF662S HNF463J, HNF663J, (700) 2.8 (309) 6.48 (65) (756) 8.47 (25) 0.27 (7) HNF663S HNF464J, HNF664J, (94) 9.2 (486) 6.78 (72) 38.6 (969) 3.44 (34) 0.33 (8) HNF664S Figure : Type Figure 2 : Type 2/3R and 4X /29

POWER PRODUCT Safety Switches. Contents - Safety Switches 3 SAFETY SWITCHES

POWER PRODUCT Safety Switches. Contents - Safety Switches 3 SAFETY SWITCHES POWER PRODUCT Safety es ID Heavy Duty Contents - Safety es Air Conditioning Disconnects -2 Safety Guide Form Specifications -4 Feature Comparison -6 Enclosure Types -7 Light Duty switches - -8 SE and ID

More information

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1

Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-1 Sect_0_Speedfax2007 /26/07 5:05 PM Page -1 SPEEDFAX TM 2007-2008 Safety Switches Contents Safety Switch Guide Form Specifications -2 Feature Comparison - Enclosure Types -4 Catalog Numbering System -5

More information

General and Heavy Duty Safety Switches

General and Heavy Duty Safety Switches General and Heavy Duty Safety es Accessories 10/01/13 Selection 4 Class R Fuse Clip Kits All General Duty and Heavy Duty es are field convertible to accept Class R Fuse Clip Kits. The kits prevent the

More information

Product Guide. NEMA pump controls.

Product Guide. NEMA pump controls. Product Guide NEMA pump controls www.usa.siemens.com/controls Class 87 full voltage pump controller with fusible disconnect switch and standard features Class 87 NEMA full starter pump control panels Product

More information

Switches. Safety and Disconnect Switches. Heavy Duty Safety Switch Standards and Ratings

Switches. Safety and Disconnect Switches. Heavy Duty Safety Switch Standards and Ratings Safety and Disconnect es Contents Pages Heavy Duty Safety es Safety Features........................18/2 Selection, 240V Fusible........................18/3 Selection, 600V Fusible........................18/4

More information

GHN424NW HHN426N HUN361AW

GHN424NW HHN426N HUN361AW GHN424NW HHN426N HUN61AW Passed The Test of Time All Murray safety switches have passed rigid testing requirements to assure reliable performance. In addition to tests designed and conducted during the

More information

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install Midwest Electric Products Safety Switches Rugged, reliable and easy to install Midwest Safety Switches Features Midwest Electric Products offers a wide variety of general duty and heavy duty safety switches,

More information

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Enclosed Rotary Switch Product Specification Sheets Table of Contents Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle

Disconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle Features 30-600A, 600VAC and DC ratings UL Recognized (file # E121152 vol. 3) and CSA Certified under file number 15852 Visible blade quick make and break switching action Panel and Flange mounted assemblies

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Effective December 2015 Supersedes September 2013

Effective December 2015 Supersedes September 2013 Technical data 1156 Supersedes September 2013 BUSSMANN SERIES CUBEFuse safety switch Standard features: Product description: Bussmann series heavy duty 600Vac safety switch with the finger-safe CUBEFuses

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch . Double-Throw, continued Rating Selection Safety Switch Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA 4X 30 N/A N/A N/A N/A 60 N/A N/A N/A DTU462DS 00 N/A N/A

More information

Safety Alert: Square D Safety Switches

Safety Alert: Square D Safety Switches Safety Alert: Square D Safety Switches Be Sure to Inspect Your Installed Units for Defects Schneider Electric has issued an offer safety alert on the Square D safety switch due to electrical shock hazard

More information

Heavy Duty Safety Switches

Heavy Duty Safety Switches eavy uty Safety Switches Class 3110 CONTENTS escription Class Page Application ata......................... 3110....................... 2-6 Technical ata........................... 3110........................

More information

Type VBII Visible Blade Disconnect Switches

Type VBII Visible Blade Disconnect Switches Type VBII Visible Blade Disconnect es Product Guide Siemens Type VBII visible blade disconnect switches meet either UL98 or UL1741 requirements and can be used in either service entrance or branch circuit

More information

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes

Breakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes Breakers and switches Enclosed switches Heavy duty safety switches Fusible and non-fusible 30 1200 Amperes Heavy duty fusible and non-fusible safety switches 30 1200 Amperes Features, product overview

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch Double-Throw, continued Ampere Rating Catalog Number Selection Safety Switch Catalog Number Eaton General Electric Siemens Square D Non-Fusible, Four-Pole, Four-Wire, 600 Vac, NEMA X 30 N/A N/A N/A N/A

More information

Safety Switches. c o n t e n t s SPEEDFAX TM 2017

Safety Switches. c o n t e n t s SPEEDFAX TM 2017 Safety Switches SPEEDFAX TM 2017 Section General Duty Switch Heavy Duty Switch Window Switch c o n t e n t s Safety Switch Guide Form Specifications -2 Feature Comparison -3 Enclosure Types - ing System

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere

CABINET - INSTRUMENT TRANSFORMER Indoor - Outdoor, 480 Volt Maximum 1200, 1600, 2000 Ampere Printed from NIPSCO.com 04-01-17 PAGE 1 OF 6 USE: 1. For commercial and industrial installation, purchased and installed by the customer. 2. To enclose 600 volt insulation class instrument transformers

More information

Selection and application guide

Selection and application guide Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

Switches Safety and Disconnect Switches

Switches Safety and Disconnect Switches es Safety and Disconnect es Contents Pages Contents Pages Heavy Duty Enclosed Safety es Features and Benefits.......................... 18/2 240V Selection............................... 18/3 600V Selection..........................

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures

Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures Safety Switches Section 4 Accessories: NEMA Type 1 and 3R Enclosures 30-600 Amperes: TG and TH 800-1200 Amperes: TC Equipment Ground Kits Ampere Rating AWG/kcmil Copper AWG/kcmil Aluminum Standard Package

More information

File E Vol. 3 Sec. Gen. Page 1 Issued: Revised: Type VBII enclosed switch components for OEM assembly.

File E Vol. 3 Sec. Gen. Page 1 Issued: Revised: Type VBII enclosed switch components for OEM assembly. File E252 Vol. Sec. Gen. Page Issued: 2007-0-02 Revised: 20-0-8 GENERAL PRODUCT COVERED: Type VBII enclosed switch components for OEM assembly. * GENERAL CONSTRUCTION: This product shall comply with the

More information

Safety and Disconnect Switches

Safety and Disconnect Switches Safety and Disconnect es Industrial Controls Product 2017 Section c o n t e n t s Heavy Duty Enclosed Safety es Features and Benefits /2 240V Selection /3 600V Selection /4 - /5 es with Viewing Window

More information

Safety Switches DH361FWK. NEMA 4 Enclosure Watertight, Painted Steel Catalog Number. Price U.S. $

Safety Switches DH361FWK. NEMA 4 Enclosure Watertight, Painted Steel Catalog Number. Price U.S. $ January 1 Vol. 1, ef. No. [0247] eavy uty, Fusible, - 361FK NEMA 12 Enclosure Industrial ust-tight NEMA 4 Enclosure atertight, Painted Steel Enclosure Corrosion esistant, Stainless Steel 2-Pole 40V AC

More information

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection Table of Contents Introduction...2 Safety Switches...4 Symbols...6 Need for Circuit Protection...8 Fuses... 13 Fuse Ratings and Classifications... 16 Enclosures... 19 Switch Design...24 Safety Switch Ratings...29

More information

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches Bulletin 494V Variable Depth, Flange Operated Disconnect Switch Kits for and Amperes (Series A) Switches ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase

More information

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

1. Division 26 Section Elevator Shunt-Trip Fused Disconnect Switches. SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,

More information

Installation Instructions for Replacement Mechanism Kit

Installation Instructions for Replacement Mechanism Kit s Siemens Industry,Inc. Item: Replacement Switch Kit Catalog Numbers HM6123 & HM6123S For use with: 30-100 Amp VBII Safety Switches Page 1 of 5 SAFETY INSTRUCTIONS NOTE: This instruction outlines the recommended

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

General and Heavy Duty Safety Switches Accessories

General and Heavy Duty Safety Switches Accessories eneral and Heavy uty Safety es Accessies Selection HR612 HT63 HN612 lass R use lip Kits All eneral uty and Heavy uty es are field convertible to accept lass R use lip Kits. The kits prevent the installation

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW preliminary information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. www.usa.siemens.com/controls

More information

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth

More information

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects

Low Voltage Switches. Enclosed switches - eot Manual motor controllers and disconnects Low Voltage Switches Enclosed switches - eot Manual motor controllers and disconnects The next generation of enclosed switches General information The eot series of enclosed manual motor controllers are

More information

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Power Mod Standard switch modules (type WS) are designed for flexibility, space savings, & durability. Features include: QuickSystem features Standard compression lug capability Invertibility: 400-800

More information

Big performance in a small package

Big performance in a small package Series Fusible & Non-fusible Sprecher + Schuh s series of fused and non-fused disconnect switches comply with service entrance requirements. This family of rod operated switches is suitable for applications

More information

600V, Non-Fusible, (3-Pole, 3 Phase)

600V, Non-Fusible, (3-Pole, 3 Phase) 0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless

More information

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits such as lighting and heat tracing in hazardous locations or in damp, wet or corrosive conditions. D2P Series designed for use in

More information

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. usa.siemens.com/controls

More information

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Arktite Heavy Duty Circuit Breaking Plugs and Connectors Arktite Heavy Duty Circuit Breaking Plugs and Connectors 60 A, 600 VAC/250 VDC, 50**-400 hertz Dimensions Page 968 1P Plug Connector Mating APJ Plugs Mating APR Connectors Style 1 Description Cat. # Dia.

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

FUSIBLE DISCONNECT SWITCHES

FUSIBLE DISCONNECT SWITCHES FUSIBLE DISCONNECT SWITCHES HIGHLIGHTS: Double break contacts per pole up to 400 A Touch safe fuse covers/line shrouding standard Service Entrance Rated Compact Footprints Front operated switches Side

More information

QMB Fusible Panelboards

QMB Fusible Panelboards Catalog 4620CT9601R04/09 2009 Class 4620 CONTENTS Description............................................. Page Overview.............................................. Page 3 QMB Switches..........................................

More information

fastfax Rock Solid TM Load Centers General Information

fastfax Rock Solid TM Load Centers General Information General Information FEATURES UL Listed. Straight-in wired, bolt-on main breaker for 100-225 amps. Neutral and ground bars have multiple 1/0 conductor terminals. Factory installed ground bars on all devices.

More information

CON EDISON EQUIPMENT

CON EDISON EQUIPMENT CON EDISON EQUIPMENT Con Ed Navtech Size Volts Amps List Spec. Cat. No Description Price 205 N-205 10x10x5 100 $72.00 205 RTN-205 10x10x5 100 190.00 215 N-215 24x12x8 200 144.00 215 RTN-215 24x12x8 200

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations, purchased and installed by customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase 4

More information

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry. www.usa.siemens.com/controls NEA Pump Controls Class 82 slim line NEA pump controller for the agricultural industry Answers for industry. Class 82 Slim Line NEA Pump Controller Typical applications include:

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

Transformer Disconnects

Transformer Disconnects Catalog April 05 Class 9070 CONTENTS Description..............................................Page Introduction................................................. 3 Standard Features............................................

More information

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A) Bulletin 494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 494C- _ Series : 600A) ATTENTION: To prevent electrical shock, disconnect from power source before installing or

More information

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine eavy Industrial/ Marine Benefits builds a variety of benefits into one plug, receptacle and interlock system for your application. Safety Waterproof construction: standard neoprene O ringed interior components

More information

IN2 Enclosed Switches and Circuit Breakers

IN2 Enclosed Switches and Circuit Breakers Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Enclosed Switches and Circuit Breakers Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals

More information

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A) Bulletin 494C Cable Operated Disconnect Switch Kit () Installation Instructions (Cat 494C- _ Series : ) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.

More information

New York City Apartment Metering Meter Sockets / Load Centers

New York City Apartment Metering Meter Sockets / Load Centers s New York City Apartment Metering Meter Sockets / Load Centers Selection and Application Guide Bulletin RPSA-S0001 Before You Begin... System Parameters Mounting: Indoor only Input: 208Y/120V AC, 3 Phase,

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753 Depth x  Width x 2.375 Height 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 7842 40A 600V 2P Switch Pass & Seymour/Legrand Catalog Number 7842 Manufacturer Pass & Seymour/Legrand Weight per unit

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D) Bulletin 494V Variable Depth Disconnect Switch Installation Instructions (Cat 494V-DS400; -DSX400 - Series D) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.

More information

Load Break Disconnect Switches FSLBS

Load Break Disconnect Switches FSLBS Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable

More information

Section 4. Safety Switches.

Section 4. Safety Switches. Quick Selection Guide, Enclosure Types...4-2 General Duty, Type TG...4-5 eavy Duty, Type T...4-7 eavy Duty Stainless Steel, Type T...4-11 Mill Duty, Type T...4-13 Double Throw Switches, Type TC, TDT...4-15

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary

More information

Product Guide. enclosed NEMA STARTERS

Product Guide. enclosed NEMA STARTERS Product Guide enclosed NEMA STARTERS The Right Choice for Applications that Demand the Best. Siemens NEMA Combination and Non- Combination Starters for Industrial and Construction Applications Rugged,

More information

ENCLOSED DISCONNECT SWITCHES

ENCLOSED DISCONNECT SWITCHES Ferraz Shawmut Enclosed isconnect es are designed to meet customer s requirements for compact and durable individual disconnecting means. Both fusible and non-fusible versions are available in a variety

More information

1.1. Switching Devices

1.1. Switching Devices . Switching Devices Six-Pole Motor Circuit Contents Description Page Product Overview......................... V2-T-2 General Duty............................. V2-T-24 Heavy-Duty..............................

More information

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Product guide. Enclosed NEMA starters. usa.siemens.com/controls Product guide Enclosed NEMA starters usa.siemens.com/controls The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction

More information

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊ Series U/CSA Fused Amp Rating 1 Ø (60Hz) Maximum Horsepower ➊ Three Phase (60Hz) DC Switch (typical) (A) 120V 240V 200V 240V 460V 600V 125V 250V Catalog Number Price U Class J and CSA HRCI-J Fuses ➋ 30

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty switches are designed with the most up-todate disconnect

More information

Air Conditioning Disconnects

Air Conditioning Disconnects .1 Product Description............................................. 2 Application Description........................................... 2 Features, Benefits and Functions...................................

More information

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators

Suitable for use as: OSHA Lockout/Tagout. disconnects. Safety switches Load break switches Isolators SafeLine Compact, heavy duty disconnect 16A 00A 30A 00A Fusible SafeLine enclosed disconnect are designed to meet customer requirements in terms of safety, ease of installation, space savings and operational

More information

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits

More information

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable

More information

1.1. Switching Devices. Safety Switches

1.1. Switching Devices. Safety Switches . Catalog Number Eaton General Electric Siemens Square D Fusible, Three-Pole, Four-Wire, 20 Vac, NEMA 3R 30 DH32NRK TH32R HF32NR H32NRB 60 DH322NRK TH322R HF322NR H322NRB 00 DH323NRK TH323R HF323NR H323NRB

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas 1P Arktite Heavy Duty Circuit Breaking s and s Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically operated

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection

Introduction. Upon completion of Basics of Safety Switches you should be able to: Explain the need for circuit protection Table of Contents Introduction...2 Siemens Safety Switches...4 Switch Symbols...7 Need for Circuit Protection...9 Fuses... 17 Fuse Ratings and Classifications...21 Enclosures...24 Switch Design...31 Safety

More information

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified. SECTION 26 24 13 LOW VOLTAGE SWITCHBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com AR331 30 Amp Pin & Sleeve Recpt 3-W 3-P 250VDC/600vac Cooper Crouse-Hinds Catalog Number

More information

Product guide. Enclosed NEMA starters. Answers for industry.

Product guide. Enclosed NEMA starters. Answers for industry. Product guide Enclosed NEMA starters Answers for industry. The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction applications

More information

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AP20467S22 3W-4P 200A Plug Cooper Crouse-Hinds Catalog Number AP20467S22 Manufacturer Cooper Crouse-Hinds Description

More information

Big performance in a small package

Big performance in a small package Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! To learn the basic differences between control, load and fusible

More information

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38 Series 7 Motor (to 100A)...2 Series 7 Enclosed (to 100A)...14 Technical Information...18 Dimensions...22 Series 7 (to 315A)...29 Technical Information...36 Dimensions...38 Series 10 Fusible and Non-Fusible...45

More information

BAC Custom Engineered Controls

BAC Custom Engineered Controls BAC Custom Engineered Controls Product Detail Product Introduction......................................... K2 BAC Custom Engineered Controls Benefits....................................................

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles 1P Arktite Heavy Duty Circuit Breaking s and Receptacles Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Big performance in a small package

Big performance in a small package Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! Manual Switching Devices: Control, oad or Fusible Disconnect Switches

More information