Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)
|
|
- Arnold Lester
- 6 years ago
- Views:
Transcription
1 Bulletin 494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 494C- _ Series : 600A) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing. Follow NFPA 70E requirements. Install in suitable enclosure. Keep free from contaminants. ATTENTION: The following procedures are critical to the proper operation of the disconnect handle and switch. Failure to follow these steps can result in damage to the equipment and/or serious injury or death to the operator. Table of Contents Page Quick Installation Guide - Disconnect Switch Installation,3 - Disconnect Handle Installation 3 - Cable Mechanism Installation 4 - Connecting Rod Adjustment Procedure 5 Conversion from Right Hand to Left Hand Operation 6 Enclosure Without Handle Cutout 7 - Locate Handle - Drill Handle Holes Door Catch Mounting Bracket Installation 8 Trailer Fuse Block Installation (600A) 9 Fuse Clip Installation (600A) 0 Bulletin 494C Cable Operated Disconnect Switch Kit Components Bulletin 494C Cable Operated Disconnect Switch Kit Optional Accessory List () Printed in U.S.A.
2 QUICK INSTALLATION GUIDE IMPORTANT: When locating the 600A switch, verify that the minimum diameter for the loop of the cable between the switch mechanism and handle mechanism is not less than 6 inches. Any reduction to the diameter of the bend loop for the cable will reduce the efficiency of the cable system, and create additional drag and friction within the cable conduit. IMPORTANT: Verify that the cable assembly does not interfere with any mechanical and moving parts. Keep the cable conduit a minimum of /" from all heat sources and current carrying terminals, fuses, transformers, etc. Disconnect Switch Installation a Locate switch with right hand mechanism 8-/4" 5" 8-/4" 5" (4) - 9/3" Dia. Mounting Holes (4) - 9/3" Dia. Mounting Holes 6" Dia. Minimum Enclosure with Right Hand Flange 6" Dia. Minimum Enclosure with Left Hand Flange b Locate switch with left hand mechanism 5" 8-/4" 5" 8-/4" (4) - 9/3" Dia. Mounting Holes (4) - 9/3" Dia. Mounting Holes 6" Dia. Minimum 6" Dia. Minimum Enclosure with Right Hand Flange Enclosure with Left Hand Flange ()
3 Disconnect Switch Installation (Cont'd) Rotate crossbar to closed position. 3 Assemble the cable mechanism bracket to the disconnect switch lb-in 4 Turn the connecting rod clockwise (approximately turns) until jam nuts touch drive bar Turn the connecting rod counter-clockwise (less than turn) until hole in threaded rod aligns with hole in cable mechanism lever. Drive Bar Threaded Rod Jam Nuts Cable Mechanism Lever (3)
4 Disconnect Switch Installation (Cont'd) 6 Attach threaded rod to cable mechanism lever. 7 Assemble disconnect switch assembly to mounting plate. Threaded Rod lb-in lb-in lb-in Cable Mechanism Lever (4) - 5/6-8 thread forming screws provided with disconnect switch. Disconnect Handle Installation Install gasket. Install handle and mechanism bracket. 3 Install defeater lever lb-in (Right Hand Flange Mounted Shown) 7- lb-in NOTE: Apply grease from capsule to gasket or groove to retain gasket to handle. 3 Cable Mechanism Installation Verify that disconnect switch and handle are in the "ON" position. Rotate connecting rod (clockwise) into drive bar until it begins to exit the drive bar (approximately 8 full turns). C L O S E D (4)
5 3 Cable Mechanism Installation (Cont'd) 3 Align connecting rod with primary link. 4 Install hitch pin clip Hitch Pin Clip Connecting Rod Primary Link 5 Turn disconnect handle "OFF" and install handle mechanism spring. 4 Connecting Rod Adjustment Procedure "ON" Position ➊ Move disconnect handle to the "ON" position. ➋ If switch does not fully close, return handle to "OFF" position. ➌ Remove link spring hitch pin and disengage the connecting rod from the primary link. ➍ Turn connecting rod counter-clockwise ( or more) full turns. ➎ Re-engage connecting rod in primary link of handle, insert hitch pin and re-test ➏ Repeat ➊ - ➎ as necessary. ➐ Re-install link spring. "OFF" Position ➊ Move disconnect handle to the "OFF" position. If switch does not fully open, return handle to "ON" position. ➋ ➌ Remove hitch pin and link spring, then disengage the connecting rod from the primary link. ➍ Turn connecting rod clockwise ( or more) full turns. ➎ Re-engage connecting rod in primary link of handle, insert hitch pin and re-test. ➏ Repeat ➊ - ➎ as necessary. ➐ Re-install link spring. ATTENTION: CHECK FOR PROPER OPERATION. Upon completion of the installation instructions, no further adjustment of the cable mechanism is required. (5)
6 Conversion from Right Hand to Left Hand Operation (If Required) IMPORTANT: Switch conversion to left-hand operation requires left-hand cable mechanism. Remove drive mechanism from right side of switch (3) - 5/6-8 Hex Head Screws with disconnect switch in the "OFF" position. Rotate crossbar to closed position. 3 Reinstall drive mechanism on left side of switch ATTENTION: With switch in the "CLOSED" position, drive mechanism should align with crossbar lb-in (6)
7 Enclosure without Handle Cutout Enclosures with a Flange Thickness less than 3/6" use dimensions below to install disconnect handle. Locate Handle -/8" -/8" -3/8" -3/8" 8-3/6" 8-3/6" Top Handle Hole Right Hand Flange Left Hand Flange Drill Handle Holes ().38 Dia. Holes Top Handle Hole 5/6" /" /4" 5-/" 6-/" Square corners or up to /4" radius (7)
8 Door Catch Bracket Installation Right hand installation shown (for left hand installation follow similar procedures) Door Catch Mounting Bracket: Provided with projections for welding. Projections can also be used as a guide for drilling holes. Can be used as a template to drill corresponding holes in the enclosure door. User to supply the hardware for fastening the bracket. Fasteners must provide the degree of ingress protection for the environmental rating of the enclosure. The bracket hardware must be inaccessible to unauthorized personnel. Dimension K (3/4" to ") When using large disconnect handle kit only (494F-M or -S), use door catch provided with handle kit. When using large disconnect handle kit and small door hardware kits (494V-L, -LL, -L or -LL), use door catch provided with door hardware kit. Dimension K (-/8" to -3/8") When using large disconnect handle kit and large door hardware kits (494V-L3 or -LL3), use door catch provided with door hardware kit. Door Catch Mounting Bracket Top TOP VIEW Door Catch Enclosure Door Door Catch Mounting Bracket Flange Thickness K Door Catch - /8" - 5/8" - 3/8" Enclosure Base -/8" -/8" -3/8" -3/8" 8-3/6" 8-3/6" 3-3/4" 3-3/4" Top Handle Hole Door Catch Mounting Bracket -5/8" -5/8" Door Catch Mounting Bracket Right Hand Flange (8) Left Hand Flange
9 Trailer Fuse Block Installation (Switch Rating 600A) Note: Not required for non-fusible disconnect switch applications. Trailer Fuse Block Location (400A Class H, J, R Fuses) Trailer Fuse Block Location (600A Class J Fuses) 8-/4" 8-/4" 6-3/4" 6-3/4" A 3/6" 3-3/6" A 3/8" 3" 3-5/6" 3-5/6" -3/6" 3" Note: Terminal bolts need to be moved from disconnect switch load terminals to fuse block. -3/6" 3" 6-3/4" 6-3/4" Amps Voltage Class Fuse Clip Amp Trailer Fuse Block (494V-FSV400) Fuse Torque (lb-in) A Fuse Lug to Block Terminal H/R H/R J -3/4" 4-/4" -/8" Wire into Lug Fuse 600 Amp Trailer Fuse Block (494V-FS600) Torque (lb-in) A Fuse Lug to Block Terminal Amps Voltage Class Fuse Bolt Wire into Lug / 600 J 4-3/8" Trailer Fuse Block Location (600A - 50V / 600V Class H, R Fuses) Note: Refer to instructions provided with separately mounted fuse blocks (Catalog Numbers 49-N6 and 49-R6). (9)
10 Fuse Clip Installation (Switch Rating 600A) 400A Fuses (Class H, J, R) 600A Fuses (Class J) lb-in lb-in lb-in A Fuses (Class H, R) Note: Refer to instructions provided with separately mounted fuse blocks (Catalog Numbers 49-N6 and 49-R6). (0)
11 Bulletin 494C Cable Operated Disconnect Switch Kit Components Disconnect Switch Kit Cat No. Switch with Right Hand Mechanism 494V-DS600 (600A) Convertible in the field for Left Hand operation Switch Handle 494F-M (7-/" Painted Metal) (400A / 600A) 494F-S (7-/" Stainless Steel) (400A / 600A) Cable Mechanism Cable with Right Hand Mechanism 494C-CM3: 600A (4 Ft Cable) 494C-CM4: 600A (5 Ft Cable) 494C-CM5: 600A (6 Ft Cable) 494C-CM6: 600A (0 Ft Cable) Cable with Left Hand Mechanism 494C-CMX3: 600A (4 Ft Cable) 494C-CMX4: 600A (5 Ft Cable) 494C-CMX5: 600A (6 Ft Cable) 494C-CMX6: 600A (0 Ft Cable) Mounted with Switch 494V-FSV400 (400A Class H, J, R) 494V-FS600 (600A Class J) Fuse Block Separately Mounted 49-N6 (600A 50V / 600V Class H) 49-R6 (600A 50V / 600V Class R) 400A Fuses 40-N46 (Class H, J, 400A-50V, 400A-600V) 40-N55 (Class R, 400A-50V, 400A-600V) Fuse Clips 600A Fuses Class J - Bolts directly to switch and fuse block (no clips required) Class H, R - Fuse clips included with separately mounted fuse blocks Cat. Nos.49-N6 and 49-R6 ()
12 Bulletin 494C Cable Operated Disconnect Switch Kit Optional Accessory List Optional Accessories (Installation Instructions Included with Accessory Kits) Catalog Number and Description Electrical Interlock Switch with Right Hand Mechanism 495-N34 (-N.O./N.C.) * 495-N35 (-N.O./N.C.) * *Requires Adapter Kit 495-N36 Auxiliary Contact 595-A (-N.O.) (600A) * 595-B (-N.C.) (600A) * *Requires Adapter Kit 595-N Switch and Fuse Block 494R-N0 (CU Wire () - #/0-350 MCM) (600A or 400A Fuse Block) (3 per kit) Lug Connectors 494R-N (CU Wire () - #/0-500 MCM) (600A or 400A Fuse Block) (3 per kit) Separately Mounted Fuse Blocks 494R-N (CU Wire () - #/0-350 MCM) (600A) ( per kit) Switch Rating Fuse Class Fuse Clip Rating 50V 600V Cat No. Fuse Cover with Door 600A Non-Fusible N6 600A H, J, R 400A 400A 495-N6 600A J 600A 600A 495-N6 Available only for R.H. mounted disconnect switch. 600A H,R 600A 600A N/A () Printed in U.S.A.
Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)
Bulletin 494C Cable Operated Disconnect Switch Kit () Installation Instructions (Cat 494C- _ Series : ) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.
More informationBulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)
Bulletin 494V Variable Depth Disconnect Switch Installation Instructions (Cat 494V-DS400; -DSX400 - Series D) ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.
More informationBulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches
Bulletin 494V Variable Depth, Flange Operated Disconnect Switch Kits for and Amperes (Series A) Switches ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.
More informationTable of Contents. Quick Installation Guide 2 - Disconnect Switch Installation - Disconnect Handle Installation - Cutting Connecting Rod
ulletin 494V Variable Depth Disconnect Switch Installation Instructions (Cat 494V-DS30; -DSX30 - Series D; 494V-DS; -DSX - Series D) (Cat 494V-DS00; -DSX00 - Series D; 494V-DS00; -DSX00 - Series D) TTENTION:
More informationInstallation Instructions
Installation Instructions Bulletin 1494V Variable Depth, Flange Operated Circuit Breaker Operating Mechanisms For use with Circuit Breakers 140G-G, 140MG-G, 140G-H, 140MG-H, 140G-I, 140MG-I, 140G-J, 140MG-J,
More informationCable-Operated Disconnect Switches. Accessories
Cable-Operated Disconnect Switches Accessories Description For Use With Auxiliary Contacts 1 N.O. Contact 1494C, 1494F, 1494V, and 1494G ( 1495-N8 1 N.O. Contact (low-level switching) A) Disconnect Switches
More informationPRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES
PRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES Rockwell Automation expands its new line of Allen-Bradley Bulletin 1494C Cable-Operated, -Mounted Switches that meet industrial
More informationSwitch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, Heavy Duty Safety Switches
Step Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, Heavy Duty Safety Switches Work Description All work should be performed in accordance with NFPA 70E. Tools Required: Personal Protective
More informationSwitch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, w Neutral, Visible-Blade, Heavy Duty Safety Switches
Step Switch Base Replacement Instructions 3-Pole, 60 AMP, Fusible, w Neutral, Visible-Blade, Heavy Duty Safety Switches Work Description All work should be performed in accordance with NFPA 70E. Tools
More informationBulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism
Bulletin V Variable-Depth Flange-Mounted Circuit Breakers Product Overview/Product Selection Circuit Breaker Kits Cat. No. V-C Circuit Breaker Kit (Shown without handle and connecting rod) Bulletin V Variable-Depth
More informationBulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide
F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate
More informationPRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V
PRODUCT PROFILE BULLETIN 1494V Rockwell Automation introduces the enhanced version of Allen-Bradley Bulletin 1494V Variable-Depth, Flange-Mounted Switches that meet industrial requirements for dependable
More informationBulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches
2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin
More informationBulletin 1494V Variable Depth, Flange Operated Circuit Breaker Kits for 125A, 150A 250A and 400A Frame Sizes
ulletin 494V Variable epth, Flange Operated ircuit reaker Kits for 5A, 50A 50A and 400A Frame Sizes ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.
More informationInstallation Instructions for Replacement Mechanism Kit
s Siemens Industry,Inc. Item: Replacement Switch Kit Catalog Numbers HM6123 & HM6123S For use with: 30-100 Amp VBII Safety Switches Page 1 of 5 SAFETY INSTRUCTIONS NOTE: This instruction outlines the recommended
More informationBulletin 1494M Fixed Depth Remote Operated Disconnect Switches Renewal Parts
Page 1 of 8 Knowledgebase Technote ID # Q37160174 5/13/2005 Repair Parts for the Handle/Mechanism and Fusible Disconnect Switch Assembly (See Figure 1 on next page for exploded view of parts.) Catalog
More informationBulletin 1494F 30A, 60A, 100A Fixed-Depth Disconnect Switch (Cat 1494F-N30; 1494F-N60; 1494F-N100; Series C)
Installation Instructions ulletin 1494F, 60, Fixed-epth isconnect Switch (at 1494F-N30; 1494F-N60; 1494F-N100; Series ) WRNING: To prevent electrical shock, disconnect from power source before installing
More informationOPERATOR ADAPTER A21ABA
OPERATOR ADAPTER A21ABA Installation Instructions for Allen Bradley Bulletin 1494F Disconnect Switches And Bulletin 1494D Circuit Breaker Operating Mechanisms (For parts list, see page 2) For floor mounted
More informationDisconnect Switches Type VBII (30-600A) with Flange Mounted Operating Handle
Features 30-600A, 600VAC and DC ratings UL Recognized (file # E121152 vol. 3) and CSA Certified under file number 15852 Visible blade quick make and break switching action Panel and Flange mounted assemblies
More informationBulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers
Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled
More informationINSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. Tel 775.355.5625 550 Vista Boulevard Fax 775.355.5633 Sparks, NV 89434 info@securitron.com www.securitron.com ASSA ABLOY, the global leader in door opening solutions INSTALLATION
More informationInstallation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches
I.L. 29C284B File 29-000 Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON
More informationFlange Mounted Disconnect Switch. Installation Instructions. Item: I.L. No A00 1 / 12 VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F
Flange Mounted Disconnect Switch Item: VBFS321F VBFS361F VBFS322F VBFS362F VBFS363F VBFS364F VBNFS361F VBNFS362F VBNFS363F VBNFS364F Installation Instructions Hazardous Voltage. 1 / 12 I.L. No. 500524A00
More informationSIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A
The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.
More informationInstructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere
331114-1 INSTRUCTION SHEET Instructions for Installation, Operation and Maintenance of: "WSRD" Interlocked Receptacles 30, 60 & 100 Ampere Read instructions carefully and with full understanding for safe
More informationUSER MANUAL Bulletin 1512A 400A One-High Cabinet Standard and Arc-Resistant Enclosure
Medium Voltage CONTROLLERS USER MANUAL Bulletin 1512A 400A One-High Cabinet Standard and Arc-Resistant Enclosure Important User Information Solid-state equipment has operational characteristics differing
More information600V, Non-Fusible, (3-Pole, 3 Phase)
0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless
More informationPatriot. Aluminum and Steel 5spring. Step #1 Tarp Spool with Gear Motor (Includes Instructions for Optional Wind Deflector)
Aluminum and Steel 5spring Qty. Component Parts Description: LONG BOX: (1) 103 Aluminum Tarp Axle (2) 98 Upper Arms with 90 Degree Elbow (2) Lower Aluminum ( 84 ) (1) Aluminum Cross Tube SMALL HARDWARE
More information* * E996L Series. E996L for Rim/Vertical. E996L for Mortise CAUTION
*921297-00* 921297-00 Electric Locking Trim E996L Series Installation Instructions CAUTION Product is shipped in Fail Safe (FS) configuration. Fail Safe configuration is required by code in some applications
More informationCCP2-FLR1-21_ flange-rod operating mechanism
Installation manual 3A3747 Rev A Contents Description Page General information 1 Required tools 2 Hardware contents 2 Installation and adjustment 2-6 Flange drilling pattern 7 HAZARD OF ELECTRIC SHOCK,
More informationIsolation Switch (behind barrier & inspection window) Power Fuses. Load Cable Connection Box. Contactor. Control Power Transformer Secondary Fuse
Instruction Bulletin Class 8198 ISO-FLEX Medium Voltage Controller Model 3, Series B Installation and Maintenance Bulletin No. 50006-376-01 August, 1995 Raleigh, NC, USA TABLE OF CONTENTS Introduction...
More informationPLEASE READ THESE INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION
PART NUMBER: L0SSJ000 INSTALLATION INSTRUCTIONS DESCRIPTION: FORESTER TRAILER HITCH PLEASE READ THESE INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION SAFETY PRECAUTION: When installing Trailer Hitch,
More informationGE Industrial Solutions. Limitamp * AR. Arc Resistant Medium Voltage Motor Control. Installation Guide
GE Industrial Solutions Limitamp AR Arc Resistant Medium Voltage Motor ontrol Installation Guide Table of ontents Introduction...3 Opening Medium Voltage oor...3 Medium Voltage oor Latches... Isolation
More information650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present
TOMMY GATE OWNER'S / OPERATOR'S MANUAL 650 Series 650 LB Capacity 650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present Installing the Base Plate 1. Examine the interior
More informationEXTERNAL DISCONNECT ENCLOSURE INSTALL
The Intent and Purpose of the EXD Enclosure is to: 1) Isolate the primary power supply. 2) Initiate appropriate PPE for entry. 3) Prevent unauthorized entry, disconnect power before entry, and requiring
More informationInstallation Instructions
DODGE 24K Industry Standard Rail Heavy Duty Custom Mounting Kit #2230 Gross Trailer Weight (Maximum)...24,000 lbs. Vertical Load Weight (Max. Pin Weight)...6,000 lbs. SYSTEM TOW CAPACITY Please note, in
More informationCOOKSON OWNER'S MANUAL
COOKSON OWNER'S MANUAL FDO-A10 INDUSTRIAL DUTY FIRE DOOR OPERATOR R L I S T E D 3040233 US CONTROL PANEL SERIAL# OPERATOR SERIAL# 9001.DWG ECN 0959 REV 4 SPECIFICATIONS MOTOR TYPE:...INTERMITTENT HORSEPOWER:...1/8
More informationInstallation Instructions
Installation Instructions Rear Disc Brake Conversion Kit Item # RC4001, RC4001X Applications: Mopar 7.25, 8.25, 9.25 Axles Thank you for choosing Leed Brakes for your automotive product needs. Before you
More informationFeeder Circuit Breaker Units Secure Support Pan and Change Door Latch
Installation Instructions Feeder Circuit Breaker Units Secure Support Pan and Change Door Latch Catalog Numbers 2193FZ Topic Page About This Publication 1 Required Tools 1 Important User Information 2
More informationWARNING! THIS PRODUCT MUST BE INSTALLED BY A TRAINED, AUTHORIZED RICON SERVICE TECHNICIAN.
II. INSTALLATION T he chapter provides instructions for installing the RICON RDO2900 Series Internal Power Swing Door Operator into full-size 1992 and later Ford vans, 1990 and later Chevrolet & GMC vans,
More informationEnclosure for AMP1 Series Energy Meters with Swing Panel Kit
GE Industrial Solutions DET-809 Installation Instructions AMP1N4 Enclosure for AMP1 Series Energy Meters with Swing Panel Kit Safety FCC PART 15 INFORMATION NOTE: This equipment has been tested by the
More informationENCLOSURES & PANELS. The Trusted Source for Innovative Control Solutions
ENCLOSURES & PANELS The Trusted Source for Innovative Control Solutions 1-717-767-6511 999 This page intentionally left blank. 1000 www.redlion.net MODEL ENC13 - NEMA 4 ENCLOSURES FOR CUB7 This enclosure
More informationKT101 Series Governor System Installation Kit Cummins 4B(T) / 6B(T) With CAV/DPA Pump
KT101 Series Governor System Installation Kit Cummins 4B(T) / 6B(T) With CAV/DPA Pump 30 Years Strong! Introduction The KT101 Series Governor System Installation Kit provides the necessary brackets and
More informationInstallation Instructions
DODGE 20K Industry Standard Rail Custom Mounting Kit #2740 Gross Trailer Weight (Maximum)...20,000 lbs. Vertical Load Weight (Max. Pin Weight)...5,000 lbs. SYSTEM TOW CAPACITY Please note, in order to
More informationHaul-Your-Might T3. Product Name: Product Code: Please read all instructions carefully before assembly, installation and/or use of this product.
WARNING: DO NOT exceed 800 lbs. (363 Kgs) WARNING: DO NOT exceed vehicle manufacturer s weight rating. Tools Required: 17mm Socket 5mm Hex Key 1/8 Hex Key Tape Measure 17mm Wrench 13mm Socket Hack Saw
More informationOPERATOR ADAPTER ABF
OPERATOR ADAPTER ABF Installation Instructions for Allen-Bradley Bulletin 1494F Series B Disconnect Switches (For parts list, see Page 2) Rev. B 2018 Hoffman Enclosures Inc. PH 7634222211 nvent.com/hoffman
More informationPublication: PDI-010 Date: March 5, 2010 Model: UXV 500
Publication: PDI-00 Date: March 5, 200 Model: UXV 500 (Orginal issue: September 25, 2008) Subject: Assembly & Pre-Delivery Instructions Proper assembly and preparation of the UXV500 is essential for the
More informationSEQUESTR. External Disconnect Enclosure. Rev. A 2014 Pentair Equipment Protection PH hoffmanonline.com P/N
SEQUESTR External Disconnect Enclosure Rev. A 2014 Pentair Equipment Protection PH 763 422 2211 hoffmanonline.com P/N 89114180 89114234 SEQUESTER Instruction Table of Contents SEQUESTR Hardware...3 SEQUESTR
More informationInstallation & Maintenance Instructions for FSQC 100 Ampere Receptacle
303359 INSTRUCTION SHEET Installation & Maintenance Instructions for FSQC 100 Ampere Receptacle RETAIN THIS INSTRUCTION SHEET FOR FUTURE REFERENCE. For safe installation and operation, please read these
More information650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present
TOMMY GATE OWNER'S / OPERATOR'S MANUAL 650 Series 650 LB Capacity 650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present Installing the Base Plate 1. Examine the interior and exterior
More informationDODGE SuperRail Mounting Kit #0848
DODGE SuperRail Mounting Kit #0848 #1200 Super 5 th (16K) #0800 Super 5 th (20.5K) Gross Trailer Weight (Maximum) Vertical Load Weight (Max. Pin Weight) 16,000 lbs. 4,000 lbs. Gross Trailer Weight (Maximum)
More informationInstallation Instructions
DODGE 20K Industry Standard Rail Custom Mounting Kit #2742 Gross Trailer Weight (Maximum)...20,000 lbs. Vertical Load Weight (Max. Pin Weight)...5,000 lbs. SYSTEM TOW CAPACITY Please note, in order to
More informationUniversal Super Shield & Ultimate Aluminum w/electric Drive Conversion Kits , , Installation Instructions
WLH 09/19/16 111-0215 & 112-0215 607-0026 For technical support call us at (800) 368-3075 or visit our website at PullTarps.com. TABLE OF CONTENTS ***Assembly*** Conversion Kit-Universal Super Shield ***Wiring,
More informationInstallation Instructions
Installation Instructions Rear Disc Brake Conversion Kit Item # RC2001, RC2001X Applications: Mopar 8-3/4 & 9-3/4 Rear Axles Thank you for choosing Leed Brakes for your automotive product needs. Before
More informationibusway for Data Center
ibusway for Data Center PBPQOD Plug-In Units with 15 60 A Circuit Breakers for Use On Busway Straight Sections Class 5600 Installation S1B99523 06/2012 Hazard Categories and Special Symbols Read these
More informationREV READ BEFORE INSTALLATION OF KIT:
REV. 05-08 QTY 3D PN. FCS PART NUMBER DESCRIPTION 1 691509 A7EDG-7820049-AAPLN EDGE BODY KIT- V6 B PCS & EXH TIPS 1 691256 A 7 E D G - 7 8 20049-BAPLN EDGE BODY KIT- V6 8PCS & EXH TIPS W/HITCH 1 691501
More informationw w w. h d o n l i n e s h o p. d e ROAD TECH QUEST GLOBAL POSITIONING SYSTEM (GPS) MOUNTING KIT GENERAL INSTALLATION -J03554 REV.
-J03554 REV. 007-08-0 ROAD TECH QUEST GLOBAL POSITIONING SYSTEM (GPS) MOUNTING KIT GENERAL Kit Number 900-05 Models For model fitment information, please see the P&A Retail Catalog or the Parts and Accessories
More informationSIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A
Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability
More informationInstructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller
Introduction: Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller The following is a set of instructions for retrofitting a Model 98 Digital
More informationSIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong
More informationPreferred Cutout, Disconnect Enclosure, Type 12
763.422.2600 Spec-00245 J763.422.2211 Wall-Mount Preferred-Cutout s Preferred Cutout, s, Type 12 Wall-Mount Preferred-Cutout s Preferred Cutout, s, Type 12 Preferred Cutout, Enclosure, Type 12 INDUSTRY
More informationOperation and Maintenance Manual
DEH-41482 GE Energy Industrial Solutions Low Voltage Switchgear Remote Racking Operator For AKR Circuit Breakers Cat. # AKREGRR 115 VAC, 60/50 Hertz Operation and Maintenance Manual TABLE OF CONTENTS Section
More informationInstruction Bulletin. Jockey Pump Controller
Instruction Bulletin Jockey Pump Controller Installation Start Up Service This instruction bulletin is a guide for personnel involved with maintenance, engineering and approval of Fire Pump equipment and
More informationINSTALLATION INSTRUCTIONS AND OPERATION MANUAL
INSTALLATION INSTRUCTIONS AND OPERATION MANUAL FS Series Rolling Fire Door Operators UL325-2010 Compliant Restricted Duty Operators CORPORATION IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the
More informationAUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS
AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS The original TOMMY GATE hydraulic lift Assembling the Auxiliary Battery Box 1. Remove the cover from the auxiliary battery box by removing the two nuts and
More information2-row and All-row systems included.
Ag Leader Technology Cotton Picker Installation Installation Instructions for John Deere cotton picker models: 2-row and All-row systems included. IMPORTANT: Ensure the model numbers shown above correspond
More informationWall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type 12
763.422.2600 SPEC-00245 L763.422.2211 DISCONNECT WALL-MOUNT PREFERRED-CUTOUT DISCONNECTS PREFERRED CUTOUT, DISCONNECTS, TYPE 12 Wall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type
More informationCutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.
Cutler-Hammer Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv DANGER HAZARDOUS VOLTAGE. READ AND UNDERSTAND THIS BOOKLET IN ITS
More informationDisconnect Enclosures
Wall-Mount Enclosures Type 12 Flange-Mount....................................................................... 296-298 Wall-Mount Enclosures Type 4 & 4X Premier Series 2-Point or 3-Point Locking..........................
More informationInstallation Instructions For Motor Control Center (MCC) Units
s Page 1 of 8 Installation Instructions December, 2013 Installation Instructions For Motor Control Center (MCC) Units Hazardous voltage. Will cause death or serious injury. Always de-energize and ground
More informationInstruction Sheet Kit Number:
Instruction Sheet Kit Number: 7914400 POWERED DECK LIFT KIT WARNING: FAILURE TO FOLLOW INSTRUCTIONS could result in personal injury and/or damage to unit. Read, understand and follow all safety practices
More informationPLEASE READ THIS INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION
INSTALLATION INSTRUCTIONS PART NUMBER: L0SXC000 DESCRIPTION: 09 ASCENT TRAILER HITCH PLEASE READ THIS INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION SAFETY PRECAUTION: When installing Trailer Hitch,
More informationRear Door: Service and Repair REAR DOOR
2007 Toyota Matrix L4-1.8L (1ZZ-FE) Copyright 2013, ALLDATA 10.52 Page 1 Rear Door: Service and Repair REAR DOOR Rear Door 2007 Toyota Matrix L4-1.8L (1ZZ-FE) Copyright 2013, ALLDATA 10.52 Page 2 ISASSEMBLY
More informationDraper Platform Adaptation Bundle
Draper Platform Adaptation Bundle 7050-Series Self-Propelled Forage Harvester 900D-Series Draper Platform RC042050 Operator s Manual Includes installation, operating, adjustment, technical, repair parts
More informationch2200 ch2300 mt3 osprey pro-trim single s twin s sl-3 INSTALLATION INSTRUCTIONS AND OWNERS MANUAL
MEMBER INSTALLATION INSTRUCTIONS AND OWNERS MANUAL Part # IS-CH2200/2300, Rev, 08/203 www.seastarsolutions.com ch2200 ch2300 mt3 osprey pro-trim single s twin s sl-3 MANUFACTURED BY MARINE ACQUISITION
More informationEPLX and D2LX lighting panelboards Installation & maintenance information IF 1813 APPLICATION D2LX/EPLX IF SHEET TABLE OF CONTENTS WEIGHTS
EPLX and D2LX lighting panelboards Installation & maintenance information APPLICATION EPLX and D2LX panelboards provide a centrally controlled switching system and short circuit protection for feeder or
More informationDetroit Speed, Inc. Rear QUADRAlink Conversion Kit Camaro/Firebird P/N:
Detroit Speed, Inc. Rear QUADRAlink Conversion Kit 1982-92 Camaro/Firebird P/N: 041721 The Detroit Speed Inc. QUADRAlink Conversion Kit, eliminates the factory torque arm configuration. It features no-compromise
More informationDigitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers
Supersedes IL 33-858-4 Dated 05/02 Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Digitrip Retrofit System for ITE K-3000, Digitrip Retrofit System for ITE K-3000, K-3000
More informationOPERATOR ADAPTER ABBSV
OPERATOR ADAPTER ABBSV Installation Instructions for ABB Variable Depth, Small Handle, Disconnect Switches (For parts list, see Page 2) Rev. B 2018 Hoffman Enclosures Inc. PH 7634222211 nvent.com/hoffman
More informationCENTERLINE 2100 Motor Control Centers 600A, 800A, and 1200A Bolted Pressure Contact Switch
Instructions CENTERLINE 2100 Motor Control Centers 600A, 800A, and 1200A Bolted Pressure Contact Switch CENTERLINE 2100 Motor Control Centers Introduction The intent of this publication is to provide field
More information460 HORIZON DR. SUITE 100 SUWANEE, GA PHONE: FAX: Renegade 3 Sidebar.
Page 1/5 Part #11591.11 6 7 10 5 9 8 4 8 7 3 2 1 1. Driver/Left Sidebar (1) 2. Passenger/Right Sidebar (1) 3. Driver/Left Mounting Bracket (1) 4. Passenger/Right Mounting Bracket (1) 5. Driver/Left Mounting
More informationParkit360 Transformer
Parkit360 Transformer 1 Owner s Manual Introduction We know you re busy, and need to get that fifth wheel moved. Now. So with that in mind, we ve kept these instructions as brief as possible, but they
More informationSELF DRILL SCREWS FILLER STRIP
r ve Pickup Lift Mounting Instructions Fullsize Ford Trucks- F-150 2015-present Preparing the Gate 1. Remove the mounting hardware which is banded to the liftgate. 2. Verify mounting bracket kit (Figure
More informationCutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter
Operation, and Maintenance of the Instruction Bulletin Read and understand these instructions before attempting any installation, operation, or maintenance of the. This equipment shall be installed and
More informationFord Super Duty Recoil Traction Bar System. Part#: ,123409
Part#: 123418,123409 Ford Super Duty Recoil Traction Bar System Rev. 011017 491 W. Garfield Ave., Coldwater, MI 49036. Phone: 517-279-2135 Web/live chat: www.bds-suspension.com. E-mail: tech-bds@sporttruckusainc.com
More informationC-10 INSTALLATION INSTRUCTIONS
GROSS LOAD CAPACITY WHEN USED AS A WEIGHT CARRYING HITCH: 30,000 LBS. TRAILER WEIGHT & 6,000 LBS. TONGUE WEIGHT. ***DO NOT EXCEED VEHICLE MANUFACTURER'S RECOMMENDED TOWING CAPACITY.*** Parts List ITEM
More informationINSTALLATION & OWNER S MANUAL
INDUSTRIES, LLC. INSTALLATION & OWNER S MANUAL CAB INSTALLATION INSTRUCTIONS KUBOTA GRAND L 40 SERIES HARD SIDED CAB ENCLOSURE (p/n 1KGL4AS) This Curtis Cab is designed and manufactured for use only as
More informationDead Tank Outdoor Vacuum Circuit Breaker, Type VOX
Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX Class 6065 Instruction Bulletin 6065-13 11/2011 Retain for future use. Hazard Categories and Special Symbols Read these instructions carefully and look
More informationKT230 Series Caterpillar 3406 Governor System Installation Kit
KT230 Series Caterpillar 3406 Governor System Installation Kit 30 Years Strong! Introduction The KT230 Series Governor System Installation Kit provides the necessary brackets and hardware to install a
More informationR24. Instruction manual
R24 roller Instruction manual - 16570 Installer: read and understand this manual. Fully instruct and demonstrate the operation of this 5th wheel hitch to the end user. Include the importance of observing
More informationUniversal Mounting Kit #0820
Universal Mounting Kit #0820 #1200 Super 5 th (16K) #0800 Super 5 th (20.5K) Gross Trailer Weight (Maximum) Vertical Load Weight (Max. Pin Weight) 16,000 lbs. 4,000 lbs. Gross Trailer Weight (Maximum)
More informationM-5220-MB Mustang GT Side Exhaust Kit INSTALLATION INSTRUCTIONS
Please visit www.fordracingparts.com for the most current instruction information.!!! PLEASE READ ALL OF THE FOLLOWING INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION. AT ANY TIME YOU DO NOT UNDERSTAND THE
More information2010+ Victory Cross Country / Cross Roads Installation Guide Nov 2014
2010+ Victory Cross Country / Cross Roads Installation Guide Nov 2014 125 Industrial Drive Spearfish, SD 57783 Toll Free 888.3WHEELS w w w. l e h m a n t r i k e s. c o m UNDERSTANDING SAFETY LABELS &
More informationIt don t mean a thing If it ain t got the swing
SWING CHUTE SAND/SALT SPREADER INSTALLATION AND OPERATING INSTRUCTIONS SWING CHUTE SPREADER MODELS: 7, 8, 9, 9.5 & 10 MANUAL FOR SPREADER SERIAL NUMBERS AFTER # 20000 It don t mean a thing If it ain t
More informationInstallation Instructions
Installation Instructions Rear Disc Brake Conversion Kit Item # RC1001, RC1001X Applications: 64-72 A-body, 67 F-Body, 63-67 X-body with Non Staggered Shocks Thank you for choosing GPS Auto for your automotive
More informationWOC-364 Installation Instructions Ranger XP Heater System
WOC-364 Installation Instructions Ranger 2011-12 XP Heater System Order of installation for a Complete Enclosure Always install the Heater System first if possible NOTE: If installing the Heater System
More informationAn Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches
An Investment in Plant Floor Safety 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches Notes 2 802C Cable Pull Safety Switches Safety and Application Safety
More informationSentinel Field Satellite Controller
WARNING HIGH VOLTAGE 115V M AP Sentinel Field Satellite Controller Installation Instructions Important: For your protection and the safety of the product user, please comply with all Caution and Warning
More informationHorsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R
Safety Switches Heavy Duty 240 Volt Indoor Type Outdoor Type 3R Horsepower Ratings 240V AC Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* 2 Wire 4 Wire 3 Wire System Rating
More informationINSTALLATION INSTRUCTIONS AM rev. A
INSTALLATION INSTRUCTIONS AM16629-1 rev. A READ THIS MANUAL CAREFULLY! FAILURE TO INSTALL THIS EQUIPMENT PER THESE INSTRUCTIONS WILL VOID THE WARRANTY. INTRODUCTION NOTE: Zebra technologies Corporation
More information