COMMAND Series. Switching-disconnectors units
|
|
- Annabelle Lambert
- 5 years ago
- Views:
Transcription
1 COMMND Series Switchingdisconnectors units
2 COMMND Series > ROTRY SWITCHES > REFERENCE STNDRDS EN 6097 Low voltage switchgear and controlgear. Part : switches disconnectors, switchdisconnectors and fusecombination unit. UL 508 Industrial control equipement. > QULITY MRKS i For specific quality marks please contact our technical service. > VERSIONS > TECHNICL CHRCTERISTICS Switching units Front panel mounting Box mounting Switching units with fues carrier Box mounting Front operators x IP65 Front panel mounting Box mounting Front operators 8x8 IP65 Front panel mounting Box mounting Front operators 8x8 IP65 padlocable Front panel mounting Box mounting Polarity: 2P P P Rated current: 16 0 Rated voltage: 0 Vac 0600Vdc Frequency: 5060Hz Insulating voltage: Vac 0Vdc 600Vdc Protection degree: IP65 (front operator) Operating temperature according to the reference standard: C+ C Max. operating temperature: 60 C Glow Wire test: 850 C Material: Engineering plastic Fuse:,x8 DIN rail fixing: Yes Font panel fixing: Yes Connectable auxiliary contacts: Yes Front operators 70x87 Front panel mounting Direct operators Controls for DIN rail slits 2
3 > BEHVIOUR WITH CHEMICL ND TMOSPHERIC GENTS Saline solution cids Bases Solvents Concentrated Diluted Concentrated Diluted Hexane Benzol cetone lcohol Limited Resistance For specific substances please contact our technical service. Not Not Not Limited Resistance Mineral oil UV rays COMMND Series > PPLICTION EXMPLES
4 Switchingdisconnectors units > SWITCHINGDISCONNECTORS UNITS Thermal current Ith Power dissipation per pole/contact Type R (*) Front panel mtg Type B (**) Box mtg Type B Box mtg with fuse carrier 2P 0,9W 1/6 i 590.Y162R i 590.Y162B i 590.YF162B 16 P 0,9W 1/6 i 590.Y1R i 590.Y1B i 590.YF1B P 0,9W 1/6 i 590.Y16R i 590.Y16B 590.Y18.K1 i 590.YF16B 2P 1,6W 1/6 i 590.Y2R i 590.Y2B i 590.YF2B P 1,6W 1/6 i 590.YR i 590.YB 590.Y8.K1 i 590.YFB P 1,6W 1/6 i 590.YR i 590.YB 590.Y8.K1 i 590.YFB 2P 1/6 590.Y2R 590.Y2B P 1/6 590.YR 590.YB P 1/6 590.YR 590.YB 2P 1/6 i 590.Y6R i 590.Y6B P 1/6 i 590.YR i 590.YB 590.Y8.K1 P 1/6 i 590.YR i 590.YB 590.Y8.K1 2P 86 1/6 i 590.Y2R i 590.Y2B P 86 1/6 i 590.YR i 590.YB 590.Y8.K1 P 86 1/6 i 590.YR i 590.YB 590.Y8.K1 P 0 0 1/6 590.Y0R 590.Y0B 590.Y08.K1 P 0 1/6 590.Y0R 590.Y0B 590.Y08.K1 (*) Suitable as spare part for the SCME OMNI Series interlockedswitch socket outles. (**) Suitable as spare part for the SCME ISOLTORS Series and DVNCE 2 Series.
5 > SINGLE JUNCTION BOX Switch disconnectors Type Dimension (mm) Suitable for R (*) 16,, DVNCE 2 Series 16x150x Suitable for R 16,, OMNI 2 Series 16x1x Box provided for fitting of switch disconnectors (switching units and relevant front operators standard mounting). COMMND Series > DIRECT OPERTORS Switch disconnectors Colour Suitable for B 16,, 1/ 590.YMC1 switch disconnectors,, 0 1/ 590.YMC2 > COMND SWITCH FOR SWITCHBORD SLOT Rotary Switches Colour 16,, 1/ 590.YMDIN R = Front panel mounting. B = Base mounting. 5
6 Switchingdisconnectors > FRONT OPERTORS IP65 ( ) xmm Suitable for R Switch disconnectors 16,, Knob Front plate Standard mtg Ø22 mtg 1/ 590.YMR1 590.YM68R1 1/ 590.YMR2 590.YM68R2 Suitable for B with 16,, 1/ 590.YMB1 590.YM68B1 door interlock 1/ 590.YMB2 590.YM68B2 Suitable for R, 1/ 590.YMR6 0 1/ 590.YMR7 Suitable for B with, 1/ 590.YMB6 590.YM68B6 door interlock 0 1/ 590.YMB7 590.YM68B7 R = Front panel mounting. B = Base mounting (needs to be fitted extension bar). ( ) Can be padlocked (max padlocks) in the O position (open). Extension bar not supplied. For general use and emergency switches. > UXILIRY CONTCT NC contact NO contact NO= normally open. Switch disconnectors 16,, 590.PL0001, 590.PL000 16,, 590.PL0002, 590.PL000 NC= normally closed.,, CLC! 6
7 8x8mm ( ) 8x8mm ( ) 70x87mm Standard mtg Ø22 mtg Standard mtg Ø22 mtg Scame enclosures cutouts 590.YM8R1 590.YM50R1 590.YM9R1 590.YM51R1 590.YM70R1 590.YM8R2 590.YM50R2 590.YM9R2 590.YM51R2 590.YM70R2 590.YM8B1 590.YM50B1 590.YM9B1 590.YM51B1 590.YM8B2 590.YM50B2 590.YM9B2 590.YM51B2 COMMND Series 590.YM70R6 ( ) ( ) They can only be applied to slots that have clues for fastening,encased sockets. 590.YM70R7 ( ) > EXTENSION BR FOR DOOR INTERLOCK Rotary switches Lenght Dimensions Suitable for B switch disconnectors 16,,,, 0 85mm 5x5mm 1/ 590.YM mm 5x5mm 1/ 590.YM185 0mm 5x5mm 1/ 590.YM0 85mm 6x6mm 1/ 590.YMB mm 6x6mm 1/ 590.YMB185 0mm 6x6mm 1/ 590.YMB0, DPTO Series BLOCK Series The contacts may also be used as uxiliary equipments for SCME interlocked socket DVNCE 2 Series and OMNI Series, switchdisconnectors COMMND Series and control equipment TOP22 Series. DOMINO Series 590.YM
8 COMMND Series > TECHNICL DT SWITCH DISCONNECTORS with fuse without fuse YF16 YF Rated insulation voltage Ul VC VDC Rated impulse withstand voltage Uimp kv Thermal current Ith Thermal current Ithe C21 Resistive loads, including moderate overloads 0V 500V V C22 Mixed resitive and inductive loads, including moderate overloads 0V 500V V Iec rating C2 Switching off motor loads or other highly inductive loads ( phase / pole) 0V 500V V C Squirrelcage motor: starting, switching off motor during running ( phase / pole) 0V V 12 28, DC21 Resistive loads, including moderate overloads 0V 1 (2V) 160 (2V) DC22 Mixed resitive and inductive loads, including moderate overloads 0V 600V (1) (1) (1) (2V) 160 (2V) Rated shorttime withstand current Icw (1s) Conditional shortcircuit current keff 12 Shortcircuit protection ssociate fuse size for conditional shortcircuit current Type gg Rated shortcircuit making capacity. Icm General use single phase and three phase 600V 0 UL rating C motor starting break all line single phase C motor B, C, D, starting break all lines three phase 1V 2V 2V V 600V Hp Hp Hp Hp Hp Permissible wire gauge Flexible wire Flexible wire mm 2 WG mm 2 WG 1, , , , , , , , , , (1) 2+2 pules in series. UL approve values. IMQ approved values. 8
9 > FRONT PNEL MOUNTING R TYPE ø ø ø. 6 ø.5 COMMND Series ø > BOX MOUNTING B TYPE.2 2 ø.5 ø max ø16 8 L ø.5 ø22.5 L 28 max ø YM YM YM0 590.YMB YMB185 L max 1mm 2mm 5mm L max 128mm 228mm mm Note: L min mm Note: L min 98mm 9
10 COMMND Series > DIMENSIONS B TYPE 16 UXILIRY CONTCT R TYPE 16 K1 TYPE 16 UXILIRY CONTCT (Dimensions in mm)
11 B TYPE COMMND Series R TYPE K1 TYPE (Dimensions in mm) 11
IS OL ATOR S S E RIE S. Enclosed change-over switches I/O/II
IS OL TOR S S E RIE S Enclosed changeover switches I/O/II ISOLTORS Series ENCLOSED CHNGEOVER SWITCHES I/O/II, 0 1 Poles IP degree IP65(*) 1/5 IP65(*) 1/5 IP65(*) 1/5 IP65(*) 1 IP65(*) 1 THERMOPLSTIC LUMINIUM
More informationTechData. Master data. P/N: SCM460MI7W INTERLOCK SOCKET 3P+E IP67 60A 7h **Supplied with base
ddendum 1/11/1 rticle Picture P/N: SCM0MI7W INTERLOCK SOCKET P+E IP7 0 7h **Supplied with base 79.0 P/N SCM0MI7WNB INTERLOCK SOCKET P+E IP7 0 7h **No base supplied. Select base below. Base Options: Single:
More informationADVANCE GRP Series 125A Switched Interlocked socket outlets
DVNCE GRP Series 125 Switched Interlocked socket outlets DVNCE GRP Series 125 > SWITCHED INTERLOCKED SOCKET OUTLETS > REFERENCE STNDRDS EN 60309-1 Plugs, socket outlets and couples for industrial purposes.
More information70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX
70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX SWITCH DISCONNECTORS IN METAL BOX ATEX SWITCH DISCONNECTORS IN METAL BOX The switch disconnectors in plastic boxes, which are available in control or emergency
More informationADVANCE- GRP S YS TEM. Switched Interlocked socket outlets [ ]
DVNCE GRP S YS TEM Switched Interlocked socket outlets DVNCEGRP System SWITCHED INTERLOCKED SOCKET OUTLETS 63263 REFERENCE STNDRDS EN 60309 Plugs, socket outlets and couplers for industrial purposes. Part
More informationswitch disconnectors switch disconnectors fuses
SWITCHGER R switch disconnectors RB switch disconnectors fuses R switch disconnectors and RB switch disconnectors fuses are designed for distribution of electricity, making and breaking currents and protection
More informationELECTRICAL CHARACTERISTICS. Permissible overload (A) 22 > transformer 42 > > > > >
IEC 309 TS New range of plugs and socket-outlets meeting the dimensional, construction/performance and safety requisites defined by the international Standards IEC 60309-1 and IEC 60309-2, subsequently
More informationSD Series Non-Fused Load Switches
SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load
More information67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS
Technical data and compliance with Standards Component Interlocked switched socket-outlets SELV socket-outlet Rotary switch MT60 miniature circuit breaker, C characteristic, 6kA Reference Standards EN
More informationContact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE
Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe
More informationMSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3
Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the
More informationIS OL ATORS-EX S ERIES
IS OL ATORS-EX S ERIES Switch disconnectors for applications in potentially explosive atmospheres - DUST [ ] II 2D [ II 2D] SWITCHES DISCONNECTORS REFERENCE STANDARDS EN 60079-0 Electrical apparatus for
More informationSwitches disconnectors with fuse-holders. XNF series TF series
Switches disconnectors with fuse-holders XNF series TF series Quick Reference Switch-disconnectors with fuse-holders XNF series TF series XNF Series page 155 16 32A with fuse holders 3 4 Pole Auxiliary
More information1.2 Switched socket outlets with interlock
. Switched socket outlets with interlock. OMNIA Series OMNIAPLUS Series ADVANCE Series ADVANCE System ADVANCE-GRP System ADVANCE-GRP Series 8 87 Switched socket outlets with interlock. IP IP/IP7 > V
More informationCam Switch. Rish Cam 16A Rish Cam 32A Rish Cam 100A. Rish Cam 10A Rish Cam 25A Rish Cam 63A Rish Cam 200A. Rish Cam 6A Rish Cam 20A Rish Cam 40A
Rishabh's New Rish Cam I,C,M &INS rotary cam Switches offer a complete range of cam switches for control, Instrumentation and motor starting applications, maximizing the benefits and optimizing your use
More informationRotary limit switches FCR FGR series
Rotary limit switches FCR FGR series Rotary control switches with 00mm rods from up to positions. Control switches with rotary gear from up to 00 rpm with or micro switches. 0 Rotary limit switches FCR
More informationMotor protection switches M16 20A Main switches S25 25A
Motor protection switches M16 20A Main switches S25 25A DISA Elektro AG Kägiswilerstrasse 33 CH-6060 Sarnen Tel. 041 666 70 50 Fax 041 666 70 49 info@disa.ch www.disa.ch DISA your partner for individual
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationSwitch Disconnectors
Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles
More informationUNIBOX Series Enclosure and wiring accessories IP40-IP55
UNIBOX Series Enclosure and wiring accessories IP-IP55 UNIBOX Series > ENCLOSURE FOR WIRING ACCESSORIES > REFERENCE STANDARDS EN 60670-1 Boxes and enclosures for electrical accessories for household and
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationRated current In (A) Other electrical data. IEC 309 range. EN see 70 RT range IK
44 and 67 IB standard horizontal and vertical socket-outlets Industrial-type socket-outlets conforming to IEC 309 Standard, with mechanical interlock consisting of a circuit breaker enabling the plug to
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationWhat you need to know. Â Conformity to standards
SIRCO PV Load break switches for solar applications sirco_343_a_1_cat  What you need to know A solar electrical installation is an application that requires switching devices fully meet the needs of operational
More informationPlug 16A 2P+E extra flat Wireable (body length up to 50 mm) SPA17. Plug 10A 2P+E straight S11. Plug 16A 2P+E straight S30. Plug 16A angled S30
CONTROL DEVICE REFERENCE STANDARDS UNSWITCH SOCKET OUTLETS EN 60669-1 Switches for household and similar fixed-electrical installation. Part 1: general requirements. Rated current: 10A-13A-15A-16A Rated
More informationWAYBOX Series. Junction boxes for galleries and tunnels
Junction boxes for galleries and tunnels > JUNCTION BOXES > REFERENCE STANDARDS EN 60670-22 Boxes and enclosures for electrical accessories for household and similar fixed electrical installations. Part
More informationNon-fusable disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages
More informationCATALOGUE. ON Medium Voltage Outdoor Disconnectors
CATALOGUE ON Medium Voltage Outdoor Disconnectors 2 O N M E D I U M V O LTA G E O U T D O O R D I S C O N N E C TO R S ON MEDIUM VOLTAGE OUTDOOR DISCONNECTORS 3 Table of conteants 004 1. Introduction 004
More informationMS25, MST25, MS20, MST20
Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers
More informationK50H004UP cam changeover switch - 4-pole A - screw mounting
Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationRSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX
IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description
More informationK30H001YP cam star-delta switch - 3-pole A - screw mounting
Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationPRODUCTS FOR W INERIES. Products for the wine-making industry
PRODUCTS FOR W INERIES Products for the winemaking industry Products for wineries INDEX ISOLTORSHD Series Nonfusible motor disconnect switches pg.16 2 EUREKHD Series Pin and sleeve devices pg. DVNCEGRP
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More informationXACA871 pendant control station XAC-A - 8 pushbuttons
Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional
More informationPhone: Fax: Web: -
HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right
More informationControl switch/load disconnect switch Series 8008
> s Control switch with 2, 3 or 4 pole Load switch 3 pole + 1 auxiliary contact > Rated operational voltage up to 690 V AC > Positive opening contacts > Contacts suitable for EM-STOP > Isolating characteristics
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More informationSIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A
Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability
More informationCylindrical fuse-link
Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH
More informationGeneral information about motor protection
Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch
More informationVistop TM isolating switches 63 to 160A
DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary
More informationIEC 309 RANGE PLUGS AND SOCKETS TO IEC 309 STANDARDS
IC 309 RNG PLUGS ND SOCKTS TO IC 309 STNDRDS TCHNICL CHRCTRISTICS 1 SL / 3 SL - RPID SSMLY ND WIRING PLUGS ND SOCKTS RFRNC STNDRDS The IC 309 SL industrial plugs and sockets meets the dimensional, construction-performance
More informationFUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A
Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong
More informationDCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC
More informationK50F003UP cam changeover switch - 3-pole A - screw mounting
Characteristics cam changeover switch - 3-pole - 60-50 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product
More informationK63F003UP cam changeover switch - 3-pole A - screw mounting
Characteristics cam changeover switch - 3-pole - 60-63 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationSIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC
Load break switches SIRCO PV IEC 609473 new The solution for > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar
More informationSIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC
SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar
More informationSENTRON Switching and Protection Devices Switch Disconnectors
SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP
More informationXACA871 pendant control station XAC-A - 8 pushbuttons
Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional
More informationTUNNEL54. Safety and fire resistance VENTILATION LIGHTING
TUNNEL54 Safety and fire resistance VENTILATION LIGHTING 238 TUNNEL54 Safety and fire resistance VENTILATION TUNNEL54 fire resistant sockets for ventilators Page 240 LIGHTING TUNNEL54 junction boxes with
More informationXACA871 pendant control station XAC-A - 8 pushbuttons
Characteristics pendant control station XAC-A - 8 pushbuttons Main Range of product Product or component type Device short name Complementary Control station type Enclosure material Electrical circuit
More informationChangeover & Bypass Sw it ches
Changeover & Bypass Switches St ate of the art Manufacturing Facilit ies Haridw ar, Noida Ph-I & Noida Ph-II Plant Changeover & Bypass Sw it ches Introduction On Load Changeover Switches (with & without
More informationCam switches. CA Series
Cam switches CA Series CA Series Overview The range of cam switches CA series includes ratings from to 6A and insulation voltages of 69. The CA series offers IP terminals protection degree (it s possible
More informationDPX Magnetic only
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More information, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationPhase + Neutral, neutral on left side
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1
More informationNB1 Miniature Circuit Breaker
P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide
More informationPower distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly
NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter
More informationCTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.
More informationLimit Switch - Prewired Type Metal Body
Limit Switch - Prewired Type Metal Body Sealed with epoxy resin al the base of the box Degree of protection IP67 Thermoplastic material or diecast zinc alloy body Positive Opening Operation Minimum Actuation
More informationLoad break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...
Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are
More informationSafety Performance WORLD PREMIERE. palazzoli.com 1
Safety Performance WORLD PREMIERE palazzoli.com 1 The inventions that progressed our life Benjamin Franklin Energy and persistence conquer all things. The lightning rod 2 The inventions that progressed
More informationContactor Types CI 61-98
MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories
More informationEmergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0
MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationFor many applications
Series 40 Amp Rugged and dependable 40 amp switches for industrial applications Sprecher + Schuh s rugged rotary cam switches are available for most control and load applications up to 40 amps. A well
More informationB115...B180 RF200 RFN200 B250...B400 RF400 RFN400
Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,
More informationTA25DU0.4 Overload Relay a. Features. Descriptions
3804 South Street 7594-723, TX Ncogdoches Phone: 93-59-7941 Fx: 93-50-485 0.4 Overlod Rely-0.25 0.4 Thoms&Betts-Abb Ins Prod Ctlog Number Mnufcturer Description Weight per unit Product Ctegory Fetures
More informationT-Switches Range. TL Contactors TS disconnectors TP Contactors. TELARC s multipurpose DC and AC current switches for multiple application.
TP-PNORM T-Switches Range TL Contactors TS disconnectors TP Contactors TELRC s multipurpose DC and C current switches for multiple application Rolling Stock Energy generation Substation equipment Industrial
More informationSIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A
The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.
More informationAn innovative technology
The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,
More informationC -5 to +55 (0.8 to 1.1Uc) Permissible o
T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4
More informationELECTRICAL CHARACTERISTICS. Permissible overload (A) 22 > transformer 42 > > > > >
New range of plugs and socket-outlets meeting the dimensional, construction/performance and safety requisites defined by the international Standards IE 60309-1 and IE 60309-2, subsequently assimilated
More informationPermissible overload. 22 A > A Hz > Hz 42 A > A. Heat resistance
IEC 309 HP technical characteristics New range of plugs and socket-outlets meeting the dimensional, construction/performance and safety requisites defined by the international Standards IEC 60309-1 and
More informationSWITCHGEAR. 4G cam switches
SWITCHGEAR 178 4G cam switches ENERGY SAFELY SWITCHED 179 SWITCHGEAR 180 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear
More informationSIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A
Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented
More informationIEC Low Voltage General Purpose Protection
, 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6
More informationSIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC
and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar
More informationDNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually
More informationRotary cam switches A&Z series
Rotary cam switches &Z series Rotary cam switches &Z ONTNTS ONTNTS 2 GNR 3 STNDRD MOUNTING ORMS MOUNTING S 4 DIMNSION DRWINGS 5-6 OPTION XTRS 7-8 THNI DT 9 DIMNSION DRWINGS OR OPTION XTRS 10-12 ORDR SHT
More informationCylindrical fuse-link
ylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity haracteristics Body material 00 V A, 500 V A, 90 V A H 8-5 A/00 V H 0,5- A/500 V, 0-3 A/00 V H -5
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationEmergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1
MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual
More informationMotor Protection Circuit Breakers
Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions
More informationProtection components
Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed
More informationSIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.
Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity
More informationAF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationHYPRA Prisinter 16/32/63 A
8704 LIMOGES Cedex Telephone: + 33 0 06 87 87 - Fax: + 33 0 06 88 88 HYPR Prisinter 16/32/63 Page 1. General characteristics........1 2. Range......................1 3. Dimensions............... 2-3 4.
More informationPhase + Neutral, neutral on right side
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationAF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationIEC Load Switches Bulletin 194E 25 Amps to 100 Amps
Description load switches are designed for use as local motor isolation and IEC disconnect switch applications outside North America. Available with 3- and 6-pole versions with add-on additional poles,
More information