Operating Instructions in accordance with IECEx Scheme rules, IECEx 02 polykom
|
|
- Marcia Byrd
- 5 years ago
- Views:
Transcription
1 Operating Instructions in accordance with IECEx Scheme rules, IECEx 02 polykom Page 1 of 9 Rev. A /
2 Product group: Empty enclosure polykom Terminal enclosures polykom The basic safety and health requirements are met in conformity with: IEC : 2004 Equipment General Requirements IEC : 2006 Increased Safety e IEC : 2006 Equipment protection by intrinsic safety i IEC : 2004 General Requirements Dust IEC : 2004 Protection By Enclosure td IEC : 2006 Equipment with Equipment protection level (EPL) Ga The low voltage regulations apply to enclosures with insertions. Description of the Enclosure IECEx Certificate of Conformity No.: IECEx KEM U Ex empty enclosure IECEx KEM Increased Safety e Intrinsic Safety «i» Dust explosion protection The polyester enclosure types PK 081 to PK 411 as operating material for areas with explosion hazards fulfill the requirements of IEC , IEC for Increased Safety, and IEC and IEC for Protection by enclosure of group II. It is an electrical operating material made from glass fibre reinforced polyester moulding material, black, with reduced surface resistance < 10 9 Ω. Cover and bottom part are screwed together by means of captive lid screws from VA. PK 081 PK 084 min. 1,5Nm 2,0Nm and PK 121 PK 411 min. 2,0Nm max. 2,5Nm. The sealing type is a key and slot system with a silicone sealing. For the internal installation there are fixing screw threads in the bottom ribs to which the carrying rails for clamps will be screw fastened. Fastening is also possible by inserting a mounting plate. Screw fastening channels outside the sealing space are provided for supporting the enclosure. Technical Data for empty enclosures Enclosure dimensions see type tag Protection against contact, foreign particles, and water IP65 i.a.w. IEC Operating temperature range max: 40 C C Technical Data for terminal enclosures Rated voltage max V (depending on terminal type) Cross section for connection max. 240 mm² PE cross section max. 120 mm² Protection against contact, foreign particles, and water IP65 i.a.w. IEC Ambient temperature range max: 40 C C Terminal Insertion The maximum insertion into the distributing and dividing box, depending from the conductor cross section and the permissible permanent current can be taken from the diagrams below. For the type of protection e, increased safety, only such terminals will be used, for which an IECEx Certificate of Conformity has been issued by a recognized testing institution. The clearances and creepage distances of the build-in electrical equipment in type of explosion protection increased safety e shall satisfy the requirements of Clause 4.4 and Clause 4.5 (Table 1) of IEC Connection of PE conductor Per each inserted line, one PE conductor terminal is provided. The width of the PE conductor bus or brackets depends on the size of the terminal straps. As from 10 mm² onward a PE conductor terminal strip must be inserted, or respectively, a bracket clamp on a PE conductor bus. Alternatively: PE terminals after test certificate, rated cross-section max. 240 mm 2. Internal connection facilities for earthing or bonding conductors shall satisfy the requirements of Clause 15 of IEC Installation instructions The degree of ingress protection of IP65 to IEC is only achieved if certified IP65 cable entries are used that that are suitable for the application and correctly installed. There are only cable entries used, for which an IECEx Certificate of Conformity has been issued by a recognized testing institution. There are the manufacturer's specifications to be considered. Page 2 of 9 Rev. A /
3 Identification The identification will be made in accordance with IEC , IEC and IEC The type tag consists of a self-adhesive polyester foil. Areas for intrinsically safe power circuits will be identified separately with light blue colour. Covers on the enclosure enabling the access to live, not intrinsically safe circuitry, will be identified by a tag showing the text Switch off supply before removing cover. Marking Plate Terminal Boxes Series polykom Ex e II T6 Ex td A21 IP65 T80 C Ex e ia IIC T6 Ex td A21 IP65 T80 C IECEx KEM IECEx KEM Operating temperature ra nge: -40 C C Operating temperature ra nge: -40 C C Switch off befor e removing cover R OLEC Ge häu se-systeme GmbH Switch off befor e removing cover R OLEC Ge häuse-systeme GmbH Ex ia IIC T6 Ex td A21 IP65 T80 C IECEx KEM Zone 0 Ex ia IIC T6 IECEx KEM Operating temperature ra nge: -40 C C Operating temperature ra nge: -40 C C Switch off suppl y before r emoving cover R OLEC Ge häu se-systeme GmbH Switch off suppl y before r emoving cover R OLEC Ge häu se-systeme GmbH Enclosure Series polykom Ex e II Ex td A21 IP65 IECEx KEM U Ambie nt temperature rang e: -40 C C R OLEC Ge häu se-systeme GmbH Page 3 of 9 Rev. A /
4 Conductor and terminal insertion PK-EX 081 L 80 Max. Cable glands Power in A Cross section in sqmm W 75 L L/L W/W 1,5 2, H 55 W W D 68 L PG E 45 M16 PG PG M20 PG13, PG M25 PG M32 PG29 80 M40 PG Nutzbare Usable * 7 7 länge 52mm mounting rail 52mm * Max. number of terminals in the enclosure possible PK-Ex 082 L 110 Max. Cable glands Power in A Cross section in sqmm W 75 L L/L W/W 1,5 2, H 55 W W D 98 L PG E 45 M16 PG PG M20 PG13, PG M25 PG M32 PG29 80 M40 PG Nutzbare Usable * länge 82mm mounting rail 82mm * Max. number of terminals in the enclosure possible PK-Ex 083 L 160 Max. Cable glands Power in A Cross section in sqmm W 75 L L/L W/W 1,5 2, H 55 W W D 148 L PG E 45 M16 PG PG M20 PG13, PG M25 PG M32 PG M40 PG Nutzbare Usable * länge 132mm mounting rail 132mm * Max. number of terminals in the enclosure possible Page 4 of 9 Rev. A /
5 PK-Ex 084 L 190 Max. Cable glands Power in A Cross section in sqmm W 75 L L/L W/W 1,5 2, H 55 W W D 178 L PG E 45 M16 PG PG M20 PG13, PG M25 PG M32 PG M40 PG Nutzbare Usable * länge 162mm mounting rail 162mm * Max. number of terminals in the enclosure possible PK-Ex 121 L 122 Max. Cable glands Power in A Cross section in sqmm W 120 L L/L W/W 1,5 2, H 90 W W D 106 L PG E 82 M16 PG PG M20 PG13, PG M25 PG M32 PG M40 PG Nutzbare Usable * länge 84mm mounting rail 84mm * Max. number of terminals in the enclosure possible PK-Ex 123 L 220 Max. Cable glands Power in A Cross section in sqmm W 120 L L/L W/W 1,5 2, H 90 W W D 204 L PG E 82 M16 PG PG M20 PG13, PG M25 PG M32 PG M40 PG Nutzbare Usable * länge 182mm mounting rail 182mm * Max. number of terminals in the enclosure possible Page 5 of 9 Rev. A /
6 PK-Ex 161 L 160 Max. Cable glands Power in A Cross section in sqmm W 160 L L/L W/W 1,5 2, H 90 W W D 140 L PG E 110 M16 PG PG M20 PG13, PG M25 PG M32 PG M40 PG Nutzbare Usable * länge 121mm mounting rail 121mm * Max. number of terminals in the enclosure possible PK-Ex 162 L 260 Max. Cable glands Power in A Cross section in sqmm W 160 L L/L W/W 1,5 2, H 90 W W D 240 L PG E 110 M16 PG PG M20 PG13, PG M25 PG M32 PG M40 PG Nutzbare Usable * länge 222mm mounting rail 222mm * Max. number of terminals in the enclosure possible PK-Ex 163 L 360 Max. Cable glands Power in A Cross section in sqmm W 160 L L/L W/W 1,5 2, H 90 W W D 340 L PG E 110 M16 PG PG M20 PG13, PG M25 PG M32 PG M40 PG Nutzbare Usable * länge 322mm mounting rail 322mm * Max. number of terminals in the enclosure possible Page 6 of 9 Rev. A /
7 PK-Ex 164 L 560 Max. Cable glands Power in A Cross section in sqmm W 160 L L/L W/W 1,5 2, H 90 W W D 540 L PG E 110 M16 PG PG M20 PG13, PG M25 PG M32 PG M40 PG Nutzbare Usable * länge 522mm mounting rail 522mm * Max. number of terminals in the enclosure possible PK-Ex 251 L 255 Max. Cable glands Power in A Cross section in sqmm W 250 L L/L W/W 1,5 2, H 120 W W D 235 L PG E 200 M16 PG PG M20 PG13, PG M25 PG M32 PG M40 PG Nutzbare Usable * länge 217mm mounting rail 217mm * Max. number of terminals in the enclosure possible PK-Ex 252 L 400 Max. Cable glands Power in A Cross section in sqmm W 250 L L/L W/W 1,5 2, H 120 W W D 380 L PG E 200 M16 PG PG M20 PG13, PG M25 PG M32 PG M40 PG Nutzbare Usable Tragschienen- length of länge 362mm mounting rail 362mm 250 * * Max. montierbare Klemmenanzahl im Gehäuse * Max. number of terminals in the enclosure possible Page 7 of 9 Rev. A /
8 PK-Ex 254 L 600 Max. Cable glands Power in A Cross section in sqmm W 250 L L/L W/W 1,5 2, H 120 W W D 580 L PG E 200 M16 PG PG M20 PG13, PG M25 PG M32 PG M40 PG M50 PG Nutzbare Usable Tragschienen- length of länge 562mm mounting rail 562mm 250 * * Max. montierbare Klemmenanzahl im Gehäuse * Max. number of terminals in the enclosure possible PK-Ex 411 L 400 Max. Cable glands Power in A Cross section in sqmm W 405 L L/L W/W 1,5 2, H 120 W W D 380 L PG E 355 M16 PG PG M20 PG13, PG M25 PG M32 PG M40 PG M50 PG M63 PG Nutzbare Usable Tragschienen- length of länge 363mm mounting rail 363mm * * Max. montierbare Klemmenanzahl im Gehäuse * Max. number of terminals in the enclosure possible Page 8 of 9 Rev. A /
9 Certification body Manufacturer KEMA Quality B.V. ROLEC Gehäuse-Systeme GmbH Utrechtseweg 310 Kreuzbreite AR Arnhem Rinteln The Netherlands Germany Ex-authorised person: Jürgen Müller i.a. Page 9 of 9 Rev. A /
Operating Instructions
Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety
More informationJunction box for EKL light
M EKL light Junction box Junction box for EKL light Features Chemical-resistant Temperature-resistant Flame-retardant Absolutely corrosion-proof Seawater-proof Description Polyester enclosures have proven
More informationIECEx Certificate of Conformity
Certificate of Conformity: IECEx BAS 07.0033X http://iecex.iec.ch/iecex/iecexweb.nsf/fc034777969a786bc1256d42005bd791/9e9052... Page 1 of 4 18/06/2008 IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL
More informationSegurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions
Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual and Installation Instructions Segurança PSB Heating System Cold applied connection technology Compulsório Type 27-1680-...0/...
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions Extra-low voltage up to 16 A 16, 32, 125 A > Large handle, can be locked in position 0 and I > Clear switch position indication > Optimal contact by means of self-cleaning
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1
> For use in Zones 1, 2, 21, 22 and safe area > 2-lamp version: 18 W 36 W > Housing made of sheet steel or stainless steel SS304 / > Quick fasteners www.stahl.de 15709E00 The light fittings of Series ECOLUX
More informationThe cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals
E X - J U N C T I O N B O X Plastic version for Zone 1,, 1 and The robust junction boxes made of plastic and light alloy are featured by their simple mounting and installation capability and their design.
More informationLinear Luminaire for Fluorescent Lamps Series ECOLUX 6600
> 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series 6600
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S 0 A to 25 A plugs and receptacles plastic version for zone, 2, 2 and 22 A good connection Providing electrical energy there, where it is most needed even in
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5
More informationA good connection. International approvals.
E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationHIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL
HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL Subject to change without prior notice TUM5461 REV. B 20.07.2017 IMPORTANT Read this instruction carefully before installing the product
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS RTECK terminal boxes RTKB series IEC Ex EX010 TECHNICAL FILES CONTENTS: 1) Contents 2) General information 3) Safety information 4) Conformity to standards 5) Function 6) Technical
More informationI Ex-Safety switches I
3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6401
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp
More informationI 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I
I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de
More informationLight Fitting for Fluorescent Lamps Series ECOLUX 6600
> 1- or 2-lamp version: 18 W 36 W 58 W > Enclosure in polyester resin, glass fibre reinforced and cover in polycarbonate, impact-resistant > Quick fasteners www.stahl.de 10032E00 The light fittings series
More informationPlug and Socket Devices SolConeX 16 A Series 8570
Plug and Socket Devices SolConeX 16 A Series 8570 www.stahl.de > Switch socket / plug 16 A > Minimal force required to insert and remove > Can be optionally equipped with an auxiliary contact for control
More informationSegurança. Segurança. MSB/HSB Heating System. Compulsório. Compulsório. Operation Manual/Installation Instructions. Cold applied connection technology
Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual/Installation Instructions Segurança MSB/HSB Heating System Cold applied connection technology Compulsório Type 27-1.80-...0/...
More informationExplosion protected terminal boxes type, GHG 72.
1 Technical data 1.1 Plastic terminal boxes GHG 721... ATX type examination certificate BVS 13 ATX 013 X Marking acc. to 94/9/G and standard ATX x (d e mb) II T5* -55 T amb +55 Gb x (d e mb) II T6* -55
More informationControl Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations
Unicode 2 Series: Pre-drilled Control Stations Polamide U43W211 Polyester U23W211 Compliance Data: ATEX IEC and IECEx (Polyester): Stainless Steel U62W229 Aluminum U83W211 ATEX IEC / IECEx CE Ex de IIC
More informationEX-REPAIR AND MAINTENANCE RECEPTACLES
EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand
More informationControl and Terminal Box Type A21-**-*****
e pd Control and Terminal Box Exepd GmbH i_park TAUBERFRANKEN Building 23 Becksteinerstrasse 100 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de
More informationEmergency Light Fitting for Fluorescent Lamps Series 6009
> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W and 36 W > Central locking > All-pole disconnection via N/C switch when opening light fitting or
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity Certificate No.: IECEx TUN 04.0006X Date of Issue: 2012-06-12 Issue No.: 3 Page 2 of 4 Manufacturer: FAFNIR GmbH Bahrenfelder Straße 19 22765 Hamburg Germany Manufacturing
More information5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A
.1 GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A - 630 A Safety for your protection CEAG safety switches can be protected against inadvertent switching on by our integrated locking facility
More informationEmergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy
www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity Certificate No.: IECEx TUN 04.0006X Date of Issue: 2014-04-01 Issue No.: 4 Page 2 of 4 Manufacturer: FAFNIR GmbH Bahrenfelder Straße 19 22765 Hamburg Additional Manufacturing
More informationCompact Sheet-Steel Light Fittings Series 6114/1
> As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive
More informationI Ex-safety switches I
3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99
More information9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - C O N T R O L S T A T I O N S Moulded plastic Version for Zone 1 and Zone 21 Even under the most adverse conditions, CEAG control stations can be used and operated reliably. The enclosures consist
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
Series 8570, 8571, 8575, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact
More informationI Ex-safety switches I
EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX
More informationNew products Ex Equipment 2015
New products Ex Equipment 2015 ROSE Systemtechnik GmbH ROSE Systemtechnik GmbH was founded in Porta Westfalica, Germany, in 199 and is today one of the world s leading and innovative providers of industrial
More informationHTSB system System overview
HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581
Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581 www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked in position 0 and 1 > Clear
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE
More informationBETA SWITCHES FOR HAZARDOUS AREA
BETA offers complete line of switches for (classified) hazardous locations! The BETA Switch, well known as a safety instrument, adds an extra dimension to industrial safety by having area approval up to
More information7 Lighting Technology
7 Lighting Technology Compact Emergency Light Fittings C-LUX 6108 (Zones 1 & 2, 21 & 22) C-LUX 6508 (Zones 2, 22) 01908E00 Series C-LUX 6108 and 6508 compact emergency lighting fitting can be used for
More informationCompact Sheet-steel Emergency Light Fitting Series 6118/1
www.stahl.de Compact Sheet-steel Emergency Light Fitting > Electronic ballast with integrated emergency light electronics for emergency light mode in case of power failure, charging of battery and automatic
More informationLinear Luminaire with LED Series EXLUX 6402/2
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More information7 Lighting Technology
7 Lighting Technology Light Fittings for Fluorescent Lamps Series EXLUX 6400 (Zones 2, 21 & 22) As pendant or pole-mounting fittings With electronic ballast For two-pin fluorescent lamps 1 or 2 lamp versions:
More informationMain current switches >180 A are realized in metal enclosures. Internationally approved.
E X - M A I N C U R R E N T S W I T C H E S 10 A - 80 A (up to 630 A) CEAG main current switches in a number of versions can be protected against inadvertent switching on by our integrated locking facility
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More information7 Lighting Technology
7 Lighting Technology Pendant Light Fitting IEC 10560E00 For use in Zone 2 Zone 21 and Zone 22 Three sizes are available size 1 up to 150 W size 2 up to 250 W size 3 up to 600 W Available light sources
More informationThe Ex-Cell-I series is made for instrumentation with easy access central locking system and hinged cover.
E X - T E R M I N A L E N C L O S U R E S Stainless Steel Version for Zone and Zone 2 The enclosure range is an ATEX certified enclosure / termination solution for category 2 (Zone) application with an
More informationSolenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
More informationLight Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400
> As pendant light fitting or side entry lamp > Version with 1 or 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened > End of life
More informationLED Linear Luminaire Series EXLUX 6402
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the
More informationMagnetic switch For bypass level indicators Model BGU for nuclear power plants
Level measurement Magnetic switch For bypass level indicators BGU for nuclear power plants KSR data sheet BGU for NPP Applications Magnetic switches for detecting the limits of filling levels in bypass
More informationControl Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België
Control Equipment 01616E00 Position switches are used to monitor the position of moving parts of machines and plant. Can be used in safety circuits, as the device satisfies EN 60 947-5-1/DIN VDE 0660 part
More informationLinear fluorescent luminaire LED V-CG-S
(2 x 3 W) Linear fluorescent luminaire LED V-CG-S Completely monitored explosion-protected LED light Await live of the LED module from 75.000 hours Different luminous colours available 4000 K / 5600 K
More informationInstallation Accessories
Installation Accessories Elektrostatische Aufladung vermeiden. Nur mit feuchtem Tuch säubern. Evitez lez charges electrotetiques Nettoyer unkjuement avec un chifion humide. Avold electrostatic charge.
More informationSafety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66
Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS 06.0001 Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 3 4 Application
More informationPlugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581
www.stahl.de > Various versions 16 A, extra-low voltage 16, 32, 125 A > Large handle, can be locked in position 0 and 1 > Clear switch position indication > Optimal contact by means of self-cleaning laminated
More informationLinear luminaire with LED Series EXLUX 6002
> latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationMagnetic switch For bypass level indicators Model BGU
Level measurement Magnetic switch For bypass level indicators BGU KSR data sheet BGU Applications Magnetic switches for detecting the limits of filling levels in bypass level indicators Chemical and petrochemical
More informationLinear Luminaire with LED Series EXLUX 6002/2 Version IIC
> For use in hazardous areas with gas group IIC > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking
More informationVersions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve
Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE
More informationTerminal Boxes in Stainless Steel SLS**.T
Features Variant options Stainless steel enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 6 enclosure size options Various terminal and cable gland configurations
More informationLinear Luminaire with LED Series EXLUX 6002
> Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or pole mounted light fitting > Central locking > All-pole disconnection by means of an N/C switch
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of single-coated stainless
More informationEx m Solenoid Operator Type 0519
nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for
More informationLinear Luminaire for Fluorescent Lamps Series EXLUX 6001
> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened
More informationPosition Switches Series 8060/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationBattery Boxes Series 8316
www.stahl.de > Back-up power supply > Maintenance-free batteries > Low self-discharge > Extremely low gas emissions > Electrolyte-tight > No acid surface coating > Protection against total disch arge >
More information4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)
4 Remote I/O Series 86 078E00 Series 86 enclosures of glass-fibre reinforced polyester resin or of high grade steel are used in larger control stations and control station combinations. Special sizes are
More informationLighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety
4 x 18 W Surface Mounting 2 x 36 W Recessed Compliance Data: ATEX IECEx: ATEX IECEx CE Ex de IIC or Ex demb IIC (emergency version) T6 to T4 Ex td A21 T 75 C Technical Data: 18 W 36 W 58 W 1, 2, 3 & 4
More informationUnused flameproof threads for cable glands have to be closed with certified plugs.
E X - P L U G A N D R E C E P T A C L E 1 A Metallic Design for Zone 1 The explosion-protected light metal plug and receptacle devices can be used in the areas of Zone 1 and Zone 2 at no risk of explosion.
More informationUnicode 2 Series Pre-Drilled Control Stations Increased Safety Polyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum
Unicode 2 Series Pre-Drilled Control Stations Polyamide, Fiberglass Reinforced Polyester, 316L Stainless Steel, Aluminum, Type 4X ; Type 4X Applications Local control stations and motor control stations
More informationEmergency Luminaire with LED Series EXLUX 6009/1 Version IIC
> For use in hazardous areas with gas group IIC > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central
More informationRosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications
Product Data Sheet Rosemount 3051 FIELDBUS PROTOCOL Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof
More informationEExe and EExi terminal boxes in polyester and aluminium for Ex areas
EExe and EExi terminal boxes in polyester and aluminium for Ex areas All BERNSTEIN polyester and aluminium enclosures are available in EExe and EExi versions T II 2 G EEx e II T6 or EEx e ia IIC T6 or
More informationEmergency Luminaire with LED Series EXLUX 6409/1
> Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually
More informationOperating Instructions
Operating Instructions Load and Motor Switch, Load-Break Switch > 8544/1 Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Designated Use...4 5 Technical
More informationEX-D ENCLOSURES AND DISTRIBUTIONS
EX-D ENCLOSURES AND DISTRIBUTIONS Series GHG made of metal for gases of explosion group IIC To use MCBs, fuses, contactors etc. which give off arcs in potentially hazardous areas, they must be integrated
More informationInternational approvals.
E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for
More informationPosition Switches Series 8074/2
www.stahl.de > Ex e metal enclosure > Operating temperature range -40 C... +70 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 > Extensive assortment of actuators,
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet painted > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationLoad disconnect switch Series 8146/5-V11
www.stahl.de Load disconnect switch > Motor switching capacity AC-3 and AC-23 acc. to DIN VDE 0660 part 107 IEC/EN 60947-3 > Isolating characteristics acc. to IEC/EN 60947-3 > Positive opening operation
More informationT 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators
T 365 EN Type 365 Solenoid Valve Island To control pneumatic actuators Application The Type 365 Solenoid Valve Island is a compact solution for the central control of pneumatic actuators in chemical and
More informationSPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot
SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter
More informationPlugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581
Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581 www.stahl.de > For use in Zones 2 and 22 > Various versions 16 A, extra-low voltage 16, 32, 63, 125 A > Large handle, can be locked
More informationPosition Switches Series 8070/2
www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of
More informationLimit Switch Type 4747
Limit Switch Type 4747 Ex d flameproof enclosure with inductive or mechanical contacts for linear actuators or rotary actuators acc. to VDI/VDE 3845 General The Type 4747 Limit Switch issues an electrical
More informationFloodlight LED Series 6525
www.stahl.de > Floodlight Zones 2, 21 and 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Standard enclosure made of sheet steel single powder
More informationEx e, ia Junction boxes TNCN. Features
TNCN Features The TNCN/TNCC range comprises many standard sizes of enclosure manufactured in 316L acid resistant stainless steel to give the maximum environmental protection. The main body is manufactured
More informationSegurança. Segurança. PSB Heating System Heat shrink technology. Compulsório. Compulsório. Operation Manual/Installation Instructions
Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual/Installation Instructions Segurança PSB Heating System Heat shrink technology Compulsório Type 27-1680-...0/... OCP 0004
More informationCompact Emergency Light Fittings Series C-LUX 6108 / 6508
> Operating modes non-maintained operation non-maintained operation with switchable emergency light blocking > With continous operating test > For fluorescent lamps 8 W, d 16 mm, for two-pin holder G5
More informationIECEx Certificate of Conformity
Annex Page 1 of 14 Details associated with Issue 0 Conditions of Certification: Limiting parameters and temperature classification are listed in Tables 1, 2 and 3. Table 1: ES/DS Range Maximum Power Dissipation
More informationE II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc
900/77-80-094-001 158877 For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more compact, space-saving
More informationFloodlight LED Series 6125
www.stahl.de > Floodlight Zones 1, 2 and 21, 22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated
More information4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)
.6 Ex-Floodlights for high-pressure discharge lamps, series FZD 0 / FZD EN (Zone 1, 2, 21, 22) The maintenance- and installation-friendly FZD 0 floodlights for harsh operating conditions Due to the spatial
More informationTerminal Boxes Series 8125
Series > Wide product range > Enclosure of electropolished stainless steel.0 (AISI L) or galvanised steel sheet > basic enclosure sizes various heights > Fitted according to the customer's requirements
More informationEmergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408
> As pendant light fitting or side entry lamp > Version with 2 lamps: 18 W and 36 W > Central locking > Weekly functional test > Light duration test of the emergency lighting once a year www.stahl.de 10068E00
More information2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps
.4 Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps ellk 18/18 NE / ellk 36/36 NE / ellm 18/18 NE (Zone 1,, 1, ) If you need a reliable and decentralized emergency
More informationEx UPS standard Series 8265
> Guard battery monitoring according to IEC/EN 60079 et seq. > Adjustable buffer time > Battery function test > Potential-free signal outputs > Maximum efficiency > Increased for reliable triggering of
More information