AC Motors Selection and Pricing Guide

Size: px
Start display at page:

Download "AC Motors Selection and Pricing Guide"

Transcription

1 AC Selection and Pricing Guide Catalog D81.2, U.S./Canada NEMA and IEC Answers for Industry.

2 The world s most efficient line of low voltage AC motors. Siemens NEMA and IEC motors are designed to provide maximum durability, performance, efficiency, reliability, and availability.

3 Table of Contents Introduction Table of Contents Disclaimer NEMA Motor Features at a Glance IEC Motor Features at a Glance Wide Selection of Cancellation Charges & Change Notices Warranty Procedure General Purpose GP10A High Efficiency (Cast Aluminum Frame) Horizontal, Foot Mounted C-Face, Horizontal, Foot Mounted C-Face, Horizontal, Footless GP High Efficiency (Cast Iron Frame) Horizontal, Foot Mounted C-Face, Horizontal, Foot Mounted C-Face, Horizontal, Footless RGZP High Efficiency (Cast Iron Frame) Horizontal, Foot Mounted GP100A NEMA Premium Efficiency (Cast Aluminum Frame/Aluminum Rotor) Horizontal, Foot Mounted NEMA Premium Efficiency Plus (Cast Aluminum Frame/Copper Rotor) Horizontal, Foot Mounted GP NEMA Premium Efficiency (Cast Iron Frame/Aluminum Rotor) Horizontal, Foot Mounted C-Face, Horizontal, Footless NEMA Premium Efficiency Plus (Cast Iron Frame/Copper Rotor) Horizontal, Foot Mounted C-Face, Horizontal, Footless (GP ) (RGZP ) Options (GP ) Low Voltage AC Selection and Pricing Guide 1-1

4 Table of Contents Introduction Table of Contents Disclaimer NEMA Motor Features at a Glance IEC Motor Features at a Glance Wide Selection of Cancellation Charges & Change Notices Warranty Procedure General Purpose GP10A High Efficiency (Cast Aluminum Frame) Horizontal, Foot Mounted C-Face, Horizontal, Foot Mounted C-Face, Horizontal, Footless GP High Efficiency (Cast Iron Frame) Horizontal, Foot Mounted C-Face, Horizontal, Foot Mounted C-Face, Horizontal, Footless RGZP High Efficiency (Cast Iron Frame) Horizontal, Foot Mounted GP100A NEMA Premium Efficiency (Cast Aluminum Frame/Aluminum Rotor) Horizontal, Foot Mounted NEMA Premium Efficiency Plus (Cast Aluminum Frame/Copper Rotor) Horizontal, Foot Mounted GP NEMA Premium Efficiency (Cast Iron Frame/Aluminum Rotor) Horizontal, Foot Mounted C-Face, Horizontal, Footless NEMA Premium Efficiency Plus (Cast Iron Frame/Copper Rotor) Horizontal, Foot Mounted C-Face, Horizontal, Footless (GP ) (RGZP ) Options (GP ) SD High Efficiency Horizontal, Foot Mounted C-Face, Horizontal, Footless RGZESD Low Voltage AC Selection and Pricing Guide

5 Table of Contents High Efficiency Horizontal, Foot Mounted SD10 MS High Efficiency (1 Winding Variable Torque) Horizontal, Foot Mounted NEMA Premium Efficiency (Aluminum Rotor) Horizontal, Foot Mounted C-Face, Horizontal, Footless NEMA Premium Efficiency Plus (Copper Rotor) Horizontal, Foot Mounted C-Face, Horizontal, Footless RGZEESD NEMA Premium Efficiency Horizontal, Foot Mounted NEMA Premium Efficiency (Aluminum Rotor) Horizontal, Foot Mounted NEMA Premium Efficiency Plus (Copper Rotor) Horizontal, Foot Mounted RGZEESDX NEMA Premium Efficiency Horizontal, Foot Mounted (SD ) (RGZ ) Options (SD ) Duty RGZZESD Class I, Group D, Class II, Groups F & G, Division 1 Horizontal, Foot Mounted C-Face, Vertical with Drip Cover, Footless RGZZESD ID Class I, Group D, Division 1 T2A, 1.15SF Horizontal, Foot Mounted C-Face, Vertical with Drip Cover, Footless (XP ) Options (XP ) Duty RGZESDI :1 Constant Torque Horizontal, Foot Mounted RGKESDI & RGZESDI :1 Constant Torque Horizontal, Foot Mounted RGZZESDI Class I, Group D, Class II, Groups F & G, Division 1 Horizontal, Foot Mounted ( Duty) Low Voltage AC Selection and Pricing Guide 1-3

6 Table of Contents Options ( Duty) Purpose Vertical Solid Shaft Normal Thrust RGZVESD RGZZVESD Class I, Group D, Division Vertical Solid Shaft In Line Thrust RGZVILESD RGZZVILESD Class I, Group D, Division (Vertical ) Options (Vertical ) IEC Standard 1LA Standard Efficiency (Cast Aluminum Frame) B3 - Foot Mounted B3 - Foot Mounted and PTC (A11) B5 - Flange, Footless (w/o canopy) B14 - Flange, Footless (w/o canopy) LA Standard Efficiency (Cast Iron Frame) B3 - Foot Mounted LA High Efficiency (Cast Aluminum Frame) B3 - Foot Mounted B3 - Foot Mounted and PTC (A11) B5 - Flange, Footless (w/o canopy) B14 - Flange, Footless (w/o canopy) LG High Efficiency (Cast Iron Frame) B3 - Foot Mounted B3 - Foot Mounted and PTC (A11) Options (IEC Standard ) IEC EX MJ6 Explosion Proof B3 - Foot Mounted MJ7 Explosion Proof B3 - Foot Mounted Options (IEC Explosion Proof ) Introduction Overview s Accessories Low Voltage AC Selection and Pricing Guide

7 Table of Contents Options Introduction Options Overview s Technical Notes General Purpose & High Efficiency GP10A / GP10 / SD NEMA Premium Efficiency (Aluminum Rotor) GP100A, GP100,, NEMA Premium Efficiency Plus (Copper Rotor) GP100A, GP100,, Multi-Speed SD10 MS & Duty RGZZESD, RGZZESD ID1, RGZZESDI Duty RGZESDI 10:1 Constant Torque RGKESDI & RGZESDI 1000:1 Constant Torque Purpose Vertical RGZVESD, RGZVILESD LA7 400V 50Hz LA6 400V 50Hz LA9 400V 50Hz V 60Hz LG6 400V 50Hz V 60Hz MJ6 400V 50Hz MJ7 400V 50Hz Dimensions GP10A-GP100A GP GP SD S S S RGZP-RGZESD-RGZZESD RGZ(Z)ESDI Fig A TEFC RGZESDI Fig B TEBC with and without Encoder RGZESDI Fig C & D Lake Shore LS56 & Internally Mounted Encoder RGZESDI Fig E Dynapar HS35 Encoder RGZESDI Fig F Lake Shore 8500 Externally Mounted Encoder RGZV(IL)ESD V-Belt Sheave Diagram Conduit Boxes LA Low Voltage AC Selection and Pricing Guide 1-5

8 Siemens NEMA Three Phase Integral Horse Power Features at a Glance General Purpose GP10A See Page 2-1 GP10 See Page 2-7 GP100A See Page 2-18 GP100 See Page 2-22 Mechanical Electrical Enclosure General Purpose - TEFC General Purpose - TEFC General Purpose - TEFC General Purpose - TEFC Efficiency High High NEMA Premium / NEMA Premium Plus NEMA Premium / NEMA Premium Plus Thrust N/A N/A N/A N/A HP Range Frame Size Frequency 60 Hertz 60 Hertz 60 Hertz 60 Hertz Power 3 - Phase 3 - Phase 3 - Phase 3 - Phase Voltage /460 & /460 & HP /460 & /460 & HP < 230/460, 575 <100HP 460V 100HP Service Factor (sine wave) Electrical Design NEMA design B NEMA design B NEMA design B NEMA design B Stator Windings Copper - Random Wound Copper - Random Wound Copper - Random Wound Copper - Random Wound Insulation Class F Meets NEMA MG1-2006, Part 31 Class F Meets NEMA MG1-2006, Part 31 Class F Meets NEMA MG1-2006, Part 31 Class F Meets NEMA MG1-2006, Part 31 Temperature Rise (sine wave) Class 1.0SF, Class 1.15SF Class 1.0SF, Class 1.15SF Class 1.0SF, Class 1.15SF Class 1.0SF, Class 1.15SF Warranty 18 Months 18 Months 18 Months 18 Months Frame Cast aluminum with bolted Cast iron Cast aluminum with Cast iron feet bolted feet End Shields Cast aluminum Cast iron Cast aluminum Cast iron Conduit Box Cast aluminum Cast aluminum Cast aluminum Cast aluminum Lead Seal Gasket Neoprene (o-rings) Neoprene Neoprene (o-ring) Neoprene Fan Cover Plastic Plastic Plastic Plastic Cooling Fan Bi-directional - polypropylene Bi-directional - polypropylene Bi-directional - polypropylene Bi-directional - polypropylene Drip Cover N/A N/A N/A N/A Rotor Die cast aluminum Die cast aluminum Die Cast Aluminum / Copper Die Cast Aluminum / Copper Shaft High strength carbon steel (C1045) High strength carbon steel (C1045) High strength carbon steel (C1045) High strength carbon steel (C1045) Bearing Type Sealed for life Sealed for life Single Shielded Sealed for life Double Shielded Bearing Inner Cap No No No No Shaft Seal / Slinger V-ring slinger - DE only V-ring slinger - DE only V-ring slinger - DE only V-ring slinger - DE only Lubrication Polyurea Polyurea Polyurea Polyurea Lube Inlet Fittings NA Alemite NA NA Lube Relief Fittings NA Plug NA NA Condensation Drain Drain holes - lowest Drain holes - lowest point (2) Drain holes - lowest point (2) Drain holes - lowest point (2) point (2) T-Drain Hardware Zinc plated Zinc plated Zinc plated Zinc plated Lifting Eyebolt Cast in ( > 75 lbs ) > 75 lbs Cast in ( > 75 lbs) > 75 lbs Nameplate Aluminum - engraved Aluminum - engraved Aluminum - engraved Aluminum - engraved Paint Epoxy enamel RAL Stone Gray Epoxy enamel RAL Stone Gray Epoxy enamel RAL Stone Gray Epoxy enamel RAL Stone Gray Vibration 0.15 IPS 0.15 IPS 0.15 IPS 0.15 IPS Low Voltage AC Selection and Pricing Guide

9 SD10 See Page 3-1 See Page 3-18 IEEE 841 See Page TEFC - TEFC / IEEE 841 (2001) - TEFC High NEMA Premium / NEMA Premium Plus NEMA Premium / NEMA Premium Plus N/A N/A N/A S S S Hertz 60 Hertz 60 Hertz 3 - Phase 3 - Phase 3 - Phase /460 & HP /460 & HP 460 & HP < 230/460, 575 <100HP 460V 100HP 20HP < 230/460, 575 <100HP 460V 100HP NEMA design B NEMA design B NEMA design B Copper - Random Wound Copper - Random Wound Copper - Random Wound Class F Meets NEMA MG1-2006, Part 31 Class F Meets NEMA MG1-2006, Part 31 Class F Meets NEMA MG1-2006, Part 31 Class 1.0F, Class 1.15SF Class 1.0SF, Class 1.15SF Class 1.0SF, Class 1.15SF 3 Years 3 Years 5 Years Cast iron Cast iron Cast iron Cast iron Cast iron Cast iron Cast iron Cast iron Cast iron Neoprene Neoprene Neoprene Cast iron Cast iron Cast iron Bi-directional - polypropylene S440 Locked & Keyed Bronze Bi-directional - polypropylene S440 Locked & Keyed Bronze Bi-directional - polypropylene S440 Locked & Keyed Bronze N/A N/A N/A Die cast aluminum Die Cast Aluminum / Copper Die Cast Aluminum / Copper High strength carbon steel (C1045) High strength carbon steel (C1045) High strength carbon steel (C1045) Double Shielded Single Shielded Regreasable inlet & outlet Cast iron Stationary Bearing Caps Double Shielded Single Shielded Regreasable inlet & outlet Cast iron Stationary Bearing Caps Single Shielded Single Shielded Regreasable inlet & outlet Cast iron Stationary Bearing Caps V-ring slinger - DE and ODE V-ring slinger - DE and ODE Inpro/Seal Bearing Isolator DE & ODE Polyurea Polyurea Polyurea Alemite Alemite Alemite Plug Plug Pressure relief T - drains - lowest point (2) T-drains - lowest point (2) T-drains - lowest point (2) Zinc plated Zinc plated Zinc plated > 75 lbs > 75 lbs > 75 lbs Stainless steel - engraved Stainless steel - engraved Stainless steel - embossed Epoxy enamel RAL Stone Gray Epoxy enamel RAL Stone Gray Epoxy enamel RAL Stone Gray 0.08 IPS (2, 4, 6 pole) 0.06 IPS (8 pole) 0.08 IPS 0.06 IPS Low Voltage AC Selection and Pricing Guide 1-7

10 Siemens 3AC Integral Horse Power Features at a Glance Duty RGZZESD See Page 4-1 RGZZESD 1D1 See Page 4-7 Mechanical Electrical Mechanical Electrical Enclosure Duty - TEFC Duty - TEFC Efficiency High High Thrust N/A N/A HP Range Frame Size S440 Frequency 60 Hertz 60 Hertz Power 3 - Phase 3 - Phase Voltage 230/ only 25HP and above Service Factor (sine wave) (sine wave), 1.0 (VFD) Electrical Design NEMA design B NEMA design B (except for derates) Stator Windings Copper - Random Wound Copper - Random Wound Insulation Class F Meets NEMA MG1-2006, Part 31 Class F Meets NEMA MG1-2006, Part 31 Temperature Rise (sine wave) Class 1.0SF & Class 1.15SF Class 1.0SF & Class 1.15SF Warranty 3 Years 3 Years Frame Cast Iron Cast Iron End Shields Cast Iron Cast Iron Conduit Box Cast Iron Cast Iron Lead Seal Gasket Neoprene Fan Cover Cast Iron Cast Iron Cooling Fan Bi-directional, Polypropylene Bi-directional, Polypropylene Drip Cover N/A N/A Rotor Die Cast Aluminum Die Cast Aluminum Shaft High Strength Carbon Steel (C1045) High Strength Carbon Steel (C1045) Bearing Type Single Shielded Single Shielded Bearing Inner Cap Stationary Bearing Caps Stationary Bearing Caps Shaft Seal / Slinger Shaft Seal DE Shaft Seal DE V-Ring Slinger DE V-Ring Slinger DE Lubrication Polyurea Polyurea Lube Inlet Fittings Alemite Alemite Lube Relief Fittings Plug Plug Condensation Drain Only T-Drain Hardware Zinc Plated Zinc Plated Lifting Eyebolt Provisions Included Provisions Included Nameplate Stainless Steel - Engraved Stainless Steel - Engraved Paint Epoxy Enamel RAL Stone Gray Epoxy Enamel RAL Stone Gray Vibration 0.08 IPS 0.06 IPS Low Voltage AC Selection and Pricing Guide

11 Duty Purpose - Vertical RGZESDI See Pages RGZZESDI See Page 5-7 RGZVESD See Page 6-1 RGZVILESD See Page 6-9 Severe / Duty - TEFC / Duty - TEFC - TEFC - TEFC High High High High N/A N/A Normal In-Line S Hertz 60 Hertz 60 Hertz 60 Hertz 3 - Phase 3 - Phase 3 - Phase 3 - Phase / / (sine wave), 1.0 (VFD) NEMA design B NEMA design B NEMA design B NEMA design B (except for derates) (except for derates) Copper - Random Wound Copper - Random Wound Copper - Random Wound Copper - Random Wound Class F Meets NEMA MG1-2006, Part 31 Class F Meets NEMA MG1-2006, Part 31 Class F Meets NEMA MG1-2006, Part 31 Class F Meets NEMA MG1-2006, Part 31 Class 1.0SF & Class 1.0SF Class 1.05F, Class 1.15SF Class 1.0SF, Class 1.15SF Class 1.15SF 3 Years 3 Years 3 Years 3 Years Cast Iron Cast Iron Cast iron Cast iron Cast Iron Cast Iron Cast iron Cast iron Cast Iron Cast Iron Cast iron Cast iron Neoprene Neoprene Neoprene Cast Iron Cast Iron Cast iron Cast iron Bi-directional, Polypropylene Bi-directional, Polypropylene Bi-directional - polypropylene Bi-directional - polypropylene N/A N/A Steel Cast Iron Die Cast Aluminum Die Cast Aluminum Die cast aluminum Die cast copper High Strength Carbon Steel (C1045) High Strength Carbon Steel High strength carbon steel (C1045) High strength carbon steel (C1045) (C1045) Single Shielded Single Shielded DE: / ODE: Open DE: Single Shielded DE & NDE: 400 Double Shielded DE: 440 Open / ODE: Single Shielded DE: Open Double Shielded NDE: Duplex angular contact Thrust bearing Stationary Bearing Caps Stationary Bearing Caps Stationary Bearing Caps Stationary Bearing Caps Shaft Seal DE V-Ring Slinger DE Shaft Seal DE V-Ring Slinger DE Shaftt Seal None V-Ring Slinger V-ring slinger - DE and ODE Polyurea Polyurea Polyurea Polyurea Alemite Alemite Alemite Alemite Plug Plug Plug Plug T-Drain Only T - drains T-drains Zinc Plated Zinc Plated Zinc plated Zinc plated Provisions Provisions Included Included Included Included Stainless Steel - Engraved Stainless Steel - Engraved Stainless Steel - Engraved Stainless Steel - Engraved Epoxy Enamel RAL Stone Gray Epoxy Enamel RAL Stone Gray Epoxy Enamel RAL Stone Gray Epoxy Enamel RAL Stone Gray 0.06 IPS 0.06 IPS 0.08 IPS 0.08 IPS Low Voltage AC Selection and Pricing Guide 1-9

12 Siemens IEC Features at a Glance IEC 1LA7 See Page 7-1 1LA6 See Page 7-10 Mechanical Electrical Enclosure TEFC TEFC Efficiency eff2 eff2 HP / kw Range 60Hz: kw 60Hz: kw 50Hz: kw 50Hz: Frame Size Frequency 50 and 60 Hertz 50 Hertz Power 3 - Phase 3 - Phase Voltage 50 Hertz, 230/ Hertz Service Factor (sine wave) Stock Electrical Design Design N Design N Stator Windings Copper - Random Wound Copper - Random Wound Insulation Class F Class F Temperature Rise Class 1.0SF, Class 1.0SF, Class 1.1SF Class 1.1SF Warranty 12/18 month 12/18 month Frame Cast Aluminum Cast Iron Endshields Cast Aluminum Cast Iron Conduit Box Aluminum Alloy Cast Iron Lead Seal Gasket Neoprene Neoprene Fan Cover Corrosion Protected Steel Plate Corrosion Protected Steel Plate Cooling Fan Plastic Plastic Rotor Die Cast Aluminum Die Cast Aluminum Bearing Type Double Shielded Double Shielded Protection Design IP55 IP55 Lubrication Lithium Lithium Lube Inlet Fittings Sealed Bearings Sealed Bearings Condensation Drain Optional Optional Hardware Zinc Plated Zinc Plated Lifting Eyebolt 30 kg and above 30 kg and above Nameplate Stainless Steel Stainless Steel Paint RAL 7030 World wide finish RAL 7030 World wide finish Vibration Acc. to DIN EN Vibration Grade A Vibration Grade A Low Voltage AC Selection and Pricing Guide

13 1LA9 See Page LG6 See Page MJ See Page 7-24 TEFC TEFC TEFC eff1 eff1 eff2 60Hz: 1/6-25 HP 60Hz: HP 60Hz: kW 50Hz: kw 50Hz: kW 50Hz: kW and 60 Hertz 50 and 60 Hertz 50 Hertz 3 - Phase 3 - Phase 3 - Phase 50 Hertz, 50 Hertz, 230/ Hertz 60 Hertz Stock 1.15 Stock Design N Design N Design N Copper - Random Wound Copper - Random Wound Copper - Random Wound Class F Class F Class F Class 1.0SF, Class 1.0SF, Class 1.0SF Class 1.15SF Class 1.15SF 12/18 month 12/18 month 12/18 month Cast Aluminum Cast Iron Cast Iron Cast Aluminum Cast Iron Cast Iron Aluminum , Aluminum Alloy , Cast Iron Neoprene Neoprene Neoprene , Aluminum Alloy 160, , Cast Iron Corrosion Protected Steel Plate Glass Reinforced Plastic Corrosion Protected Steel Plate Plastic Plastic : Plastic Die Cast Aluminum Die Cast Aluminum Die Cast Aluminum : Single Shielded : Regreasable Double Shielded IP55 IP55 IP55 Lithium Lithium Lithium 71-80: Single Shielded : Shielded : Regreasable Sealed Bearings Up To 250: Sealed Bearings Up To 250: Sealed Bearings 280 and above: Flat Type Nipple 280 and above: Flat Type Nipple Optional Standard Not Permitted Zinc Plated Zinc Plated Zinc Plated 30 kg and above 30 kg and above 30 kg and above Stainless Steel Stainless Steel Aluminum RAL 7030 World wide finish RAL 7030 Standard finish : RAL 7030 World wide finish :RAL 7030 Standard finish Vibration Grade A Vibration Grade A Vibration Grade A Low Voltage AC Selection and Pricing Guide 1-11

14 Introduction Wide Selection of General Purpose Duty Wide Selection Providing value also means having the right motor for the job. At Siemens, we offer hundreds of motor types, sizes, ratings and modifications. And, as you read these words, we are adding to this list as part of our commitment to become your single source for motors. The Right Efficiency for Your Application To meet your cost of ownership and motor management needs, Siemens offers several levels of energy efficiency in many of its motors: High NEMA Premium NEMA Premium Plus Total er Support When you re looking for a motor, look for a highly trained specialist to help you match the right motor to your specific needs. Siemens sales engineers share the knowledge, training and experience to help you solve performance or installation challenges to ensure that you will receive the best value for your investment. Our customer service center takes pride in putting our customers first. Whether it s an expedited shipment, tracking your order, or making sure your motor is properly installed, these professionals won t be satisfied until you are. Iron-Clad Quality The quality of our motors begins with the design experience we have gained through more than 100 years of manufacturing and applying motors. We build on this experience every day with new designs that incorporate the latest materials and techniques to provide even higher levels of performance, operating efficiency and reliability. Duty The World's Most Energy Efficient Line of Lower your energy costs today with the world's most energy efficient line of motors. New regulatory standards and rising energy costs create increasing pressure to maximize energy efficiency and reduce your carbon footprint. Siemens breakthrough copper-rotor motors have set new standards for efficiency. Adding copper to the stator windings, Siemens has developed motors that can withstand the heat. Two-thirds of an AC induction motor's electrical loss occurs in the stator. The addition of the copper rotor reduces wasteful, resistive heating. Copper's volumetric electrical conductivity is approximately 66% higher than aluminum. Availability Siemens has hundreds of distributor stocking locations throughout North America with a wide selection of NEMA and IEC frame sizes and ratings. are available same day from a local source you can trust. These advanced motor designs are manufactured in a state-of-the-art ISO 9001 certified facility. Here, our manufacturing technicians subject each motor to more than 100 separate quality inspections before it leaves our plant...and before it is good enough to be offered to you. These distributors are supported by multiple stocking centers and our customer service centers in Little Rockland Cincinnati. Need something special? Our modification centers have complete motor modification capabilities to help you get the exact motor you need, when you need it. Dimensions Purpose Low Voltage AC Selection and Pricing Guide

15 Cancellation Charges & Change Notices Cancellation Charges Note: A minimum charge of $100 will be assessed for any order cancellation for modified or custom motors. Stock No charges will be incurred if an order is cancelled prior to shipment. A stock motor is returnable (freight paid by purchaser) immediately after shipment if returned in new condition (original, undamaged packaging) for a minimum restocking charge of 20% of the motor net price. Non-Stock For non-stock motors, the following graph will apply to determine cancellation charges after the order is received and entered at the factory. Completion progress will be determined by a Siemens er Service Representative. A charge of 15% of the total net motor price will be assessed if an order is cancelled after it has been released for engineering and drafting whether or not the drawings have been completed and/or submitted for approval. Change Notice All change notices applied to in-process orders logged into the Siemens customer service department and requiring a product change will be subject to a $100 net charge plus the applicable modification adder. Delivery dates will be adjusted according to the type of change/ modification requested. This policy does not pertain to commercial changes such as ship to or bill to addresses. Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 1-13 Dimensions

16 Introduction Warranty Procedure General Purpose Duty Duty Purpose Dimensions Standard Terms & Conditions of Sale Warranty - Company warrants that on the date of shipment to purchaser the goods will be of the kind and quality described herein, merchantable, and free of defects in workmanship and material. If within one year from date of operation, but not more than eighteen months from date of shipment by Company, of any item of the goods, purchaser discovers that such item was not as warranted above and promptly notifies company in written thereof, Company shall remedy such defect by, at Company s option, adjustment, repair, or replacement of the item and any affected part of the goods. Purchaser shall assume all responsibility and expense for removal, reinstallation and freight in connection with the foregoing remedy. The same obligations and conditions shall extend to replacement items furnished by company here under. Company shall have the right of disposal of items replaced by it. Purchaser shall grant Company to determine any defect in the goods. In the event that adjustment, repair or replacement does not remedy the defect, the Company and Purchaser shall negotiate in good faith an equitable adjustment in the contract price. (Service calls and overtime are not covered under Siemens warranty policy). The Company s responsibility does not extend to any item of the goods which has not been manufactured and sold by Company. Such item shall be covered only by express warranty, if any, of the manufacture thereof. The Company and its suppliers shall also have no responsibility if the goods have been improperly stored, handled, or installed or if the goods have not been operated or maintained according to their ratings or according to instructions in Company or supplier furnished manuals, or if unauthorized repairs or modifications have been made to the goods. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES (EXCEPT TITLE), INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS, AND CONSTITUTES THE ONLY WARRANTY OF COMPANY WITH RESPECT TO THE GOODS. The foregoing states Purchasers exclusive remedy against Company and its suppliers for any defect in the goods or for failure of the goods to be as warranted, whether Purchaser s remedy is based on contract, warranty, failure of such remedy to achieve its essential purpose, tort (including negligence), indemnity or any other legal theory, and whether arising out of warranties, representations, instructions, installations or defects from any cause. Warranty Type A. 1 Year Standard Warranty Initial Operation 18 Months After shipment from manufacturer RG, RGE, RGE1, RGZP, RGZPSD, RGZAD, RGZE Single Phase GP10A, GP10, GP100A, GP100, 3 Years After shipment from manufacturer ESD only, RGZESD, RGZVILESD, RGZZESD, RGZEESD, HSRGZVESD, SD10, 5 Years After shipment from manufacturer RGZESDX, RGZEESDX, B. Remedy Siemens Options Repair Replace C. Purchaser's Responsibility Transportation Damage Claims Removal Freight Installation D. Specifically Excludes Improper Storage In & Out Costs Transportation Damage E. Shipment (Normal) FOB our dock Freight Allowed Low Voltage AC Selection and Pricing Guide

17 Warranty Procedure REFERENCE NOTES 1. After the inspection, contact Little Rock Plant for authorization of repair or replacement. Unapproved repairs will be denied. 2. Removal, reinstallation, freight and service calls are NOT covered by warranty. 3. A standard EASE Warranty report must be filled out and a Siemens job/p.o. # issued. The Warranty report and nameplate (if motor scrapped in the field) plus the invoice must be sent to the Little Rock Plant. 4. Premium efficiency motors will modify major repair pricing by increasing schedule 10%. 5. Allowances listed are for open drip-proof and totally enclosed, non-ventilated motors with class B or F insulation and all voltages between 100 and 600 volts. For variations consult factory. 6. Minor repairs-consist of all the operations listed under minor repairs plus the cost of material and rewinding of stator. If no allowance is shown, consult the factory. 7. Major repairs-consist of all the operations listed under major repairs plus the cost of material and rewinding of stator. If no allowance is shown, consult the factory. 8. Shaded areas represent units that will be replaced when possible, without repairs. 9. Replacement Parts-will be furnished at no Charge from the factory, i.e. bearings for 40 HP and above. 10. Replacement -will be furnished at no Charge from the factory. Should it be necessary for reasons of expediency for the service shop to replace a motor from their stock, a replacement motor will be furnished at no Charge from the factory, shipped Freight allowed. 11. Defective parts, i.e. bearings, are subject to return upon request to the factory for inspection and approval for reimbursement. DATE CODING Siemens motors are date coded by the model number/date code/serial number on the nameplate. Siemens date codes for NEMA frame size, low voltage motors built in USA and Mexico is as follows: The first digit is alphabetic and represents the month. The second and third digits are numeric and are the last two digits of the year. A = January B = February C = March D = April E = May F = June G = July H = August J = September K = October L = November M = December Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 1-15 Dimensions

18 Introduction Siemens General Purpose Duty Duty Purpose POWER CONVERSION DIVISION NEMA MOTORS 1 ST call To SEA salesman or sales office by OEM, Distributor or the End user. The following information must be supplied at this time: 1. Sales order number 2. Model or order number from the nameplate of the motor 3. Serial number or date code 4. Complete nameplate data 5. Application (blower, compressor, conveyor etc) 6. Nature of problem (electrical, mechanical etc) 2 nd call By SEA salesman or sales office by OEM, Distributor or the End user. To Siemens Warranty Administrator. Contact numbers: Phone number Fax number Vaughn.watkins@siemens.com Warranty Adminstrator will direct to the nearest recommended Siemens authorized service center. 3 rd call To the recommended Siemens authorized service center. Will direct analyzing of failure / evaluation of problem. If the problem is a manufactures defect, the Siemens Warranty Administrator Will make a determination on what the next step will be. Example ( repair or replace) 4 th call To Siemens customer to update the customer on the action taken by Siemens Vaughn Watkins Warranty Administrator Siemens Energy and Automation Power Conversion Division Little Rock, Ar Tel: Fax: Vaughn.Watkins@siemens.com IMPORTANT NOTICE MAIL INVOICE PLUS PROPER WARRANTY REPAIR REPORT TO THE WARRANTY ADMINISTRATOR. IF SIEMENS IS TO BE BILLED FOR OVERTIME, AUTHORIZATION MUST BE OBTAINED FROM WARRANTY ADMINISTRATOR BEFORE OVERTIME WORK IS PERFORMED. MATERIAL AND SERVICES ARE PURCHASED FOR RESALE AND ARE EXEMPT FROM STATE AND LOCAL SALES AND USE TAX. Frames Siemens Energy and Automation Power Conversion Division Dineen Drive Little Rock, Ar Tel: Fax: MOTOR SERVICE PROGRAM SUBJECT TO CHANGE WITHOUT NOTICE! Dimensions Low Voltage AC Selection and Pricing Guide

19 General Purpose - TEFC GP10A - (Cast Aluminum Frame) GP10A series of TEFC motors is ideal for material handling, pump, fan, compressor and other general purpose industrial applications. Specifications 1 to 20 HP 1.15 service factor, 40 C ambient 3600, 1800, 1200 or 900 RPM 3 phase, 60 Hz; /460 and 575 volt operation Meets or exceeds EPAct efficiency standards Class F insulation, Class B temperature 1.0SF NEMA Design B, Continuous Duty 143T through 256T frame Features for Long Life Frame & Bearing Housings Die cast aluminum construction for exceptional heat dissipation and structural integrity. Equipped with bolt-on feet for mounting flexibility. Condensation drain holes provided. Integrally cast lifting eyes. Unique frame fin design maximizes cooling. Rotor A unique rotor design provides improved efficiency. Large cross section bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel (C1045) shaft for maximum rotor performance. Stator/Windings Manufactured with premium electrical grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross section reduces resistance and lowers stator losses. Insulation Proprietary, inverterrated, NEMA Class F, non-hygroscopic, insulation system with Class B temperature 1.0 SF, provides an extra margin of thermal life. Varnish system application ensures maximum ire penetration to provide protection from moisture, corrosion and electrical surges. This insulation system meets or exceeds NEMA MG1-2006, Part 31 making all motors suitable for operation with adjustable frequency drives. Cooling A bi-directional, nonsparking fan is locked and keyed to the shaft. Its low-inertia design reduces windage losses, improves air flow, reduces noise and provides dependable cooling. Polycarbonate fan covers are provided on all frame sizes. Bearings Lubricated for life, oversized, complete with external bearing protection. Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. High Efficiency Oversized Conduit Box Cast aluminum construction that is larger than industry standards, diagonallysplit and rotatable in 90º increments for quick and easy connections. A ground lug is included. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Die cast aluminum construction, polycarbonate fan and fan cover, zinc-plated hardware, epoxy enamel paint and aluminum nameplate resist corrosion. Modifiable Siemens GP10A motors are available with a variety of modifications and kits. Introduction General Purpose Duty Duty Purpose Specifications table begins on the next page Low Voltage AC Selection and Pricing Guide 2-1 Dimensions

20 Introduction General Purpose Duty Duty Purpose Dimensions General Purpose - TEFC GP10A - (Cast Aluminum Frame) HP RPM Frame Voltage Type Horizontal, Foot Mounted DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) T /460 GP10A Ball 1LE21011AA114AA3 280 GPA T 575 GP10A Ball 1LE21011AA113AA3 280 GPA T /460 GP10A Ball 1LE21011AB214AA3 280 GPA T 575 GP10A Ball 1LE21011AB213AA3 280 GPA T /460 GP10A Ball 1LE21011AC314AA3 350 GPA T 575 GP10A Ball 1LE21011AC313AA3 350 GPA T /460 GP10A Ball 1LE21011CD114AA3 547 GPA T 575 GP10A Ball 1LE21011CD113AA3 547 GPA T /460 GP10A Ball 1LE21011AA214AA3 288 GPA T 575 GP10A Ball 1LE21011AA213AA3 288 GPA T /460 GP10A Ball 1LE21011AB314AA3 310 GPA T 575 GP10A Ball 1LE21011AB313AA3 310 GPA T /460 GP10A Ball 1LE21011CC114AA3 373 GPA T 575 GP10A Ball 1LE21011CC113AA3 373 GPA T /460 GP10A Ball 1LE21011CD314AA3 593 GPA T 575 GP10A Ball 1LE21011CD313AA3 593 GPA T /460 GP10A Ball 1LE21011AA314AA3 335 GPA T 575 GP10A Ball 1LE21011AA313AA3 335 GPA T /460 GP10A Ball 1LE21011AB414AA3 336 GPA T 575 GP10A Ball 1LE21011AB413AA3 336 GPA T /460 GP10A Ball 1LE21011CC314AA3 413 GPA T 575 GP10A Ball 1LE21011CC313AA3 413 GPA T /460 GP10A Ball 1LE21012AD114AA3 683 GPA T 575 GP10A Ball 1LE21012AD113AA3 683 GPA T /460 GP10A Ball 1LE21011CA114AA3 373 GPA T 575 GP10A Ball 1LE21011CA113AA3 373 GPA T /460 GP10A Ball 1LE21011CB114AA3 385 GPA T 575 GP10A Ball 1LE21011CB113AA3 385 GPA T /460 GP10A Ball 1LE21012AC114AA3 530 GPA T 575 GP10A Ball 1LE21012AC113AA3 530 GPA T /460 GP10A Ball 1LE21012AD214AA3 978 GPA T 575 GP10A Ball 1LE21012AD213AA3 978 GPA T /460 GP10A Ball 1LE21011CA314AA3 486 GPA T 575 GP10A Ball 1LE21011CA313AA3 486 GPA T /460 GP10A Ball 1LE21011CB314AA3 440 GPA T 575 GP10A Ball 1LE21011CB313AA3 440 GPA T /460 GP10A Ball 1LE21012AC214AA3 791 GPA T 575 GP10A Ball 1LE21012AC213AA3 791 GPA T /460 GP10A Ball 1LE21012BD114AA GPA T 575 GP10A Ball 1LE21012BD113AA GPA Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Stock Model Low Voltage AC Selection and Pricing Guide DOE#CC032A

21 General Purpose - TEFC GP10A - (Cast Aluminum Frame) HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) T /460 GP10A Ball 1LE21012AA114AA3 635 GPA T 575 GP10A Ball 1LE21012AA113AA3 635 GPA T /460 GP10A Ball 1LE21012AB114AA3 615 GPA T 575 GP10A Ball 1LE21012AB113AA3 615 GPA T /460 GP10A Ball 1LE21012BC114AA GPA T 575 GP10A Ball 1LE21012BC113AA GPA T /460 GP10A Ball 1LE21012BD214AA GPA T 575 GP10A Ball 1LE21012BD213AA GPA T /460 GP10A Ball 1LE21012AA214AA3 749 GPA T 575 GP10A Ball 1LE21012AA213AA3 749 GPA T /460 GP10A Ball 1LE21012AB214AA3 749 GPA T 575 GP10A Ball 1LE21012AB213AA3 749 GPA T /460 GP10A Ball 1LE21012BC214AA GPA T 575 GP10A Ball 1LE21012BC213AA GPA T /460 GP10A Ball 1LE21012BA114AA3 979 GPA T 575 GP10A Ball 1LE21012BA113AA3 979 GPA T /460 GP10A Ball 1LE21012BB114AA3 956 GPA T 575 GP10A Ball 1LE21012BB113AA3 956 GPA T /460 GP10A Ball 1LE21012BA214AA GPA T 575 GP10A Ball 1LE21012BA213AA GPA T /460 GP10A Ball 1LE21012BB214AA GPA T 575 GP10A Ball 1LE21012BB213AA GPA C-Face, Horizontal, Foot Mounted TC /460 GP10A Ball 1LE21011AA114EA3 342 GPA TC 575 GP10A Ball 1LE21011AA113EA3 342 GPA TC /460 GP10A Ball 1LE21011AB214EA3 342 GPA TC 575 GP10A Ball 1LE21011AB213EA3 342 GPA TC /460 GP10A Ball 1LE21011AC314EA3 411 GPA TC 575 GP10A Ball 1LE21011AC313EA3 411 GPA TC /460 GP10A Ball 1LE21011CD114EA3 634 GPA TC 575 GP10A Ball 1LE21011CD113EA3 634 GPA TC /460 GP10A Ball 1LE21011AA214EA3 349 GPA TC 575 GP10A Ball 1LE21011AA213EA3 349 GPA TC /460 GP10A Ball 1LE21011AB314EA3 371 GPA TC 575 GP10A Ball 1LE21011AB313EA3 371 GPA TC /460 GP10A Ball 1LE21011CC114EA3 461 GPA TC 575 GP10A Ball 1LE21011CC113EA3 461 GPA TC /460 GP10A Ball 1LE21011CD314EA3 680 GPA TC 575 GP10A Ball 1LE21011CD313EA3 680 GPA Stock Model Introduction General Purpose Duty Duty Purpose Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V DOE#CC032A Low Voltage AC Selection and Pricing Guide 2-3 Dimensions

22 Introduction General Purpose Duty Duty Purpose General Purpose - TEFC GP10A - (Cast Aluminum Frame) HP RPM Frame Voltage Type C-Face, Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TC /460 GP10A Ball 1LE21011AA314EA3 396 GPA TC 575 GP10A Ball 1LE21011AA313EA3 396 GPA TC /460 GP10A Ball 1LE21011AB414EA3 397 GPA TC 575 GP10A Ball 1LE21011AB413EA3 397 GPA TC /460 GP10A Ball 1LE21011CC314EA3 500 GPA TC 575 GP10A Ball 1LE21011CC313EA3 500 GPA TC /460 GP10A Ball 1LE21012AD114EA3 770 GPA TC 575 GP10A Ball 1LE21012AD113EA3 770 GPA TC /460 GP10A Ball 1LE21011CA114EA3 461 GPA TC 575 GP10A Ball 1LE21011CA113EA3 461 GPA TC /460 GP10A Ball 1LE21011CB114EA3 474 GPA TC 575 GP10A Ball 1LE21011CB113EA3 474 GPA TC /460 GP10A Ball 1LE21012AC114EA3 618 GPA TC 575 GP10A Ball 1LE21012AC113EA3 618 GPA TC /460 GP10A Ball 1LE21012AD214EA GPA TC 575 GP10A Ball 1LE21012AD213EA GPA TC /460 GP10A Ball 1LE21011CA314EA3 573 GPA TC 575 GP10A Ball 1LE21011CA313EA3 573 GPA TC /460 GP10A Ball 1LE21011CB314EA3 527 GPA TC 575 GP10A Ball 1LE21011CB313EA3 527 GPA TC /460 GP10A Ball 1LE21012AC214EA3 878 GPA TC 575 GP10A Ball 1LE21012AC213EA3 878 GPA TC /460 GP10A Ball 1LE21012BD114EA GPA TC 575 GP10A Ball 1LE21012BD113EA GPA TC /460 GP10A Ball 1LE21012AA114EA3 723 GPA TC 575 GP10A Ball 1LE21012AA113EA3 723 GPA TC /460 GP10A Ball 1LE21012AB114EA3 704 GPA TC 575 GP10A Ball 1LE21012AB113EA3 704 GPA TC /460 GP10A Ball 1LE21012BC114EA GPA TC 575 GP10A Ball 1LE21012BC113EA GPA TC /460 GP10A Ball 1LE21012BD214EA GPA TC 575 GP10A Ball 1LE21012BD213EA GPA TC /460 GP10A Ball 1LE21012AA214EA3 837 GPA TC 575 GP10A Ball 1LE21012AA213EA3 837 GPA TC /460 GP10A Ball 1LE21012AB214EA3 837 GPA TC 575 GP10A Ball 1LE21012AB213EA3 837 GPA TC /460 GP10A Ball 1LE21012BC214EA GPA TC 575 GP10A Ball 1LE21012BC213EA GPA TC /460 GP10A Ball 1LE21012BA114EA GPA Stock Model TC 575 GP10A Ball 1LE21012BA113EA GPA Dimensions TC /460 GP10A Ball 1LE21012BB114EA GPA TC 575 GP10A Ball 1LE21012BB113EA GPA TC /460 GP10A Ball 1LE21012BA214EA GPA TC 575 GP10A Ball 1LE21012BA213EA GPA TC /460 GP10A Ball 1LE21012BB214EA GPA TC 575 GP10A Ball 1LE21012BB213EA GPA Low Voltage AC Selection and Pricing Guide DOE#CC032A

23 General Purpose - TEFC GP10A - (Cast Aluminum Frame) HP RPM Frame Voltage Type C-Face, Horizontal, Footless DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TC /460 GP10A Ball 1LE21011AA114GA3 358 GPA TC 575 GP10A Ball 1LE21011AA113GA3 358 GPA TC /460 GP10A Ball 1LE21011AB214GA3 358 GPA TC 575 GP10A Ball 1LE21011AB213GA3 358 GPA TC /460 GP10A Ball 1LE21011AC314GA3 427 GPA TC 575 GP10A Ball 1LE21011AC313GA3 427 GPA TC /460 GP10A Ball 1LE21011CD114GA3 662 GPA TC 575 GP10A Ball 1LE21011CD113GA3 662 GPA TC /460 GP10A Ball 1LE21011AA214GA3 365 GPA TC 575 GP10A Ball 1LE21011AA213GA3 365 GPA TC /460 GP10A Ball 1LE21011AB314GA3 386 GPA TC 575 GP10A Ball 1LE21011AB313GA3 386 GPA TC /460 GP10A Ball 1LE21011CC114GA3 487 GPA TC 575 GP10A Ball 1LE21011CC113GA3 487 GPA TC /460 GP10A Ball 1LE21011CD314GA3 708 GPA TC 575 GP10A Ball 1LE21011CD313GA3 708 GPA TC /460 GP10A Ball 1LE21011AA314GA3 413 GPA TC 575 GP10A Ball 1LE21011AA313GA3 413 GPA TC /460 GP10A Ball 1LE21011AB414GA3 413 GPA TC 575 GP10A Ball 1LE21011AB413GA3 413 GPA TC /460 GP10A Ball 1LE21011CC314GA3 527 GPA TC 575 GP10A Ball 1LE21011CC313GA3 527 GPA TC /460 GP10A Ball 1LE21012AD114GA3 797 GPA TC 575 GP10A Ball 1LE21012AD113GA3 797 GPA TC /460 GP10A Ball 1LE21011CA114GA3 487 GPA TC 575 GP10A Ball 1LE21011CA113GA3 487 GPA TC /460 GP10A Ball 1LE21011CB114GA3 500 GPA TC 575 GP10A Ball 1LE21011CB113GA3 500 GPA TC /460 GP10A Ball 1LE21012AC114GA3 645 GPA TC 575 GP10A Ball 1LE21012AC113GA3 645 GPA TC /460 GP10A Ball 1LE21012AD214GA GPA TC 575 GP10A Ball 1LE21012AD213GA GPA TC /460 GP10A Ball 1LE21011CA314GA3 601 GPA TC 575 GP10A Ball 1LE21011CA313GA3 601 GPA TC /460 GP10A Ball 1LE21011CB314GA3 554 GPA TC 575 GP10A Ball 1LE21011CB313GA3 554 GPA TC /460 GP10A Ball 1LE21012AC214GA3 905 GPA TC 575 GP10A Ball 1LE21012AC213GA3 905 GPA TC /460 GP10A Ball 1LE21012BD114GA GPA TC 575 GP10A Ball 1LE21012BD113GA GPA Stock Model Introduction General Purpose Duty Duty Purpose Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V DOE#CC032A Low Voltage AC Selection and Pricing Guide 2-5 Dimensions

24 General Purpose - TEFC GP10A - (Cast Aluminum Frame) HP RPM Frame Voltage Type C-Face, Horizontal, Footless - continued DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TC /460 GP10A Ball 1LE21012AA114GA3 750 GPA TC 575 GP10A Ball 1LE21012AA113GA3 750 GPA TC /460 GP10A Ball 1LE21012AB114GA3 730 GPA TC 575 GP10A Ball 1LE21012AB113GA3 730 GPA TC /460 GP10A Ball 1LE21012BC114GA GPA TC 575 GP10A Ball 1LE21012BC113GA GPA TC /460 GP10A Ball 1LE21012BD214GA GPA TC 575 GP10A Ball 1LE21012BD213GA GPA TC /460 GP10A Ball 1LE21012AA214GA3 863 GPA TC 575 GP10A Ball 1LE21012AA213GA3 863 GPA TC /460 GP10A Ball 1LE21012AB214GA3 863 GPA TC 575 GP10A Ball 1LE21012AB213GA3 863 GPA TC /460 GP10A Ball 1LE21012BC214GA GPA TC 575 GP10A Ball 1LE21012BC213GA GPA TC /460 GP10A Ball 1LE21012BA114GA GPA TC 575 GP10A Ball 1LE21012BA113GA GPA TC /460 GP10A Ball 1LE21012BB114GA GPA TC 575 GP10A Ball 1LE21012BB113GA GPA TC /460 GP10A Ball 1LE21012BA214GA GPA TC 575 GP10A Ball 1LE21012BA213GA GPA TC /460 GP10A Ball 1LE21012BB214GA GPA TC 575 GP10A Ball 1LE21012BB213GA GPA Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Stock Model Dimensions Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide DOE#CC032A

25 General Purpose - TEFC GP10 - (Cast Iron Frame) GP10 motors are ideal for both indoor and outdoor applications and in operating atmospheres that contain moisture, dust and grit. These industry workhorses are ideal for use in material handling, pump, fan, compressor and other general purpose applications. Specifications 1 to 200 HP 1.15 service factor, 40ºC ambient 3600, 1800, 1200 or 900 RPM 3-phase, 60 Hz; /460 and 575 volt operation (143T 256T) 3-phase, 60 Hz; 230/460 volt operation under 100 HP, 460 volt 100 HP and above, 575 volt available (284T 449T) Meet or exceed EPAct efficiency standards Class F insulation, Class B temperature rise NEMA design B, continuous duty 143T 449T frame Features for Long Life Frame & Bearing Housings Cast iron construction for exceptional structural integrity & corrosion resistance, equipped with integrally cast feet. Condensation drain holes (143T-256T frames) or condensation T-drains (284T-449T frames) are provided. Lifting eyebolts are included with motors > 75 lbs. Rotor A unique rotor bar design provides improved efficiency. Large cross section bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel (C1045) shaft for maximum rotor performance. Stator/Windings Manufactured with premium electrical-grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross-section reduces resistance and lowers stator losses. Insulation Proprietary inverter-rated Class F non-hygroscopic insulation system with NEMA Class B temperature 1.0SF provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical shock. This insulation system meets or exceeds NEMA MG1-2006, Part 31, making all motors suitable for operation with adjustable frequency drives. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves air flow, reduces noise and provides dependable cooling. Polycarbonate fan covers are provided on 143T-365T frames and cast iron for frames 404T and larger. Bearings Oversized, lubricated for life (143T-256T frames). Regreasable, oversized, single shielded (284T-449T frames) with cast iron inner caps (444T 449T frames). Alemite grease fittings on the inlets and pipe plugs on the relief ports (284T 449T frames) for ease of routine maintenance. For added bearing protection, motors are equipped with a drive end shaft V-ring slinger. Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. High Efficiency Oversized Conduit Box Larger than industry standards, diagonallysplit, gasketed and rotatable in 90 increments for quick and easy connections. Leads are non-wicking and are clearly and permanently marked. Aluminum construction for frames 143T to 256T, steel for frames 284T to 405T and cast iron for 444T frames and larger. Corrosion Resistance Cast iron construction, zinc-plated hardware, epoxy enamel paint and aluminum nameplate resist rust and corrosion. Modifiable & Siemens motors are available with a wide variety of modifications or custom designs to meet your specific motor needs. Introduction General Purpose Duty Duty Purpose Specifications table begins on the next page Low Voltage AC Selection and Pricing Guide 2-7 Dimensions

26 Introduction General Purpose Duty Duty Purpose Dimensions General Purpose - TEFC GP10 - (Cast Iron Frame) HP RPM Frame Voltage Type Horizontal, Foot Mounted DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) T /460 GP10 Ball 1LE22011AA114AA3 315 GP T 575 GP10 Ball 1LE22011AA113AA3 315 GP T /460 GP10 Ball 1LE22011AB214AA3 315 GP T 575 GP10 Ball 1LE22011AB213AA3 315 GP T /460 GP10 Ball 1LE22011AC314AA3 392 GP T 575 GP10 Ball 1LE22011AC313AA3 392 GP T /460 GP10 Ball 1LE22011CD114AA3 614 GP T 575 GP10 Ball 1LE22011CD113AA3 614 GP T /460 GP10 Ball 1LE22011AA214AA3 323 GP T 575 GP10 Ball 1LE22011AA213AA3 323 GP T /460 GP10 Ball 1LE22011AB314AA3 347 GP T 575 GP10 Ball 1LE22011AB313AA3 347 GP T /460 GP10 Ball 1LE22011CC114AA3 419 GP T 575 GP10 Ball 1LE22011CC113AA3 419 GP T /460 GP10 Ball 1LE22011CD314AA3 666 GP T 575 GP10 Ball 1LE22011CD313AA3 666 GP T /460 GP10 Ball 1LE22011AA314AA3 376 GP T 575 GP10 Ball 1LE22011AA313AA3 376 GP T /460 GP10 Ball 1LE22011AB414AA3 377 GP T 575 GP10 Ball 1LE22011AB413AA3 377 GP T /460 GP10 Ball 1LE22011CC314AA3 463 GP T 575 GP10 Ball 1LE22011CC313AA3 463 GP T /460 GP10 Ball 1LE22012AD114AA3 766 GP T 575 GP10 Ball 1LE22012AD113AA3 766 GP T /460 GP10 Ball 1LE22011CA114AA3 419 GP T 575 GP10 Ball 1LE22011CA113AA3 419 GP T /460 GP10 Ball 1LE22011CB114AA3 433 GP T 575 GP10 Ball 1LE22011CB113AA3 433 GP T /460 GP10 Ball 1LE22012AC114AA3 595 GP T 575 GP10 Ball 1LE22012AC113AA3 595 GP T /460 GP10 Ball 1LE22012AD214AA GP T 575 GP10 Ball 1LE22012AD213AA GP T /460 GP10 Ball 1LE22011CA314AA3 546 GP T 575 GP10 Ball 1LE22011CA313AA3 546 GP T /460 GP10 Ball 1LE22011CB314AA3 494 GP T 575 GP10 Ball 1LE22011CB313AA3 494 GP T /460 GP10 Ball 1LE22012AC214AA3 888 GP T 575 GP10 Ball 1LE22012AC213AA3 888 GP T /460 GP10 Ball 1LE22012BD114AA GP T 575 GP10 Ball 1LE22012BD113AA GP Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Frames available after RGZP stock motors are depleted Stock Model Low Voltage AC Selection and Pricing Guide DOE#CC032A

27 General Purpose - TEFC GP10 - (Cast Iron Frame) HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) T /460 GP10 Ball 1LE22012AA114AA3 713 GP T 575 GP10 Ball 1LE22012AA113AA3 713 GP T /460 GP10 Ball 1LE22012AB114AA3 691 GP T 575 GP10 Ball 1LE22012AB113AA3 691 GP T /460 GP10 Ball 1LE22012BC114AA GP T 575 GP10 Ball 1LE22012BC113AA GP T /460 GP10 Ball 1LE22012BD214AA GP T 575 GP10 Ball 1LE22012BD213AA GP T /460 GP10 Ball 1LE22012AA214AA3 841 GP T 575 GP10 Ball 1LE22012AA213AA3 841 GP T /460 GP10 Ball 1LE22012AB214AA3 841 GP T 575 GP10 Ball 1LE22012AB213AA3 841 GP T /460 GP10 Ball 1LE22012BC214AA GP T 575 GP10 Ball 1LE22012BC213AA GP T 230/460 GP10 Ball 1LE22012CD116AA GP T 575 GP10 Ball 1LE22012CD113AA GP T /460 GP10 Ball 1LE22012BA114AA GP T 575 GP10 Ball 1LE22012BA113AA GP T /460 GP10 Ball 1LE22012BB114AA GP T 575 GP10 Ball 1LE22012BB113AA GP T 230/460 GP10 Ball 1LE22012CC116AA GP T 575 GP10 Ball 1LE22012CC113AA GP T 230/460 GP10 Ball 1LE22012CD216AA GP T 575 GP10 Ball 1LE22012CD213AA GP T /460 GP10 Ball 1LE22012BA214AA GP T 575 GP10 Ball 1LE22012BA213AA GP T /460 GP10 Ball 1LE22012BB214AA GP T 575 GP10 Ball 1LE22012BB213AA GP T 230/460 GP10 Ball 1LE22012CC216AA GP T 575 GP10 Ball 1LE22012CC213AA GP T 230/460 GP10 Ball 1LE22013AD116AA GP T 575 GP10 Ball 1LE22013AD113AA GP TS 230/460 GP10 Ball 1LE22012DA116AA GP TS 575 GP10 Ball 1LE22012DA113AA GP T 230/460 GP10 Ball 1LE22012CB116AA GP T 575 GP10 Ball 1LE22012CB113AA GP T 230/460 GP10 Ball 1LE22013AC116AA GP T 575 GP10 Ball 1LE22013AC113AA GP T 230/460 GP10 Ball 1LE22013AD216AA GP T 575 GP10 Ball 1LE22013AD213AA GP Stock Model Introduction General Purpose Duty Duty Purpose Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Frames available after RGZP stock motors are depleted DOE#CC032A Low Voltage AC Selection and Pricing Guide 2-9 Dimensions

28 Introduction General Purpose Duty Duty Purpose Dimensions General Purpose - TEFC GP10 - (Cast Iron Frame) HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing Low Voltage AC Selection and Pricing Guide List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TS 230/460 GP10 Ball 1LE22012DA216AA GP TS 575 GP10 Ball 1LE22012DA213AA GP T 230/460 GP10 Ball 1LE22012CB216AA GP T 575 GP10 Ball 1LE22012CB213AA GP T 230/460 GP10 Ball 1LE22013AC216AA GP T 575 GP10 Ball 1LE22013AC213AA GP T 230/460 GP10 Ball 1LE22013CD116AA GP T 575 GP10 Ball 1LE22013CD113AA GP TS 230/460 GP10 Ball 1LE22013BA116AA GP TS 575 GP10 Ball 1LE22013BA113AA GP T 230/460 GP10 Ball 1LE22013AB116AA GP T 575 GP10 Ball 1LE22013AB113AA GP T 230/460 GP10 Ball 1LE22013CC116AA GP T 575 GP10 Ball 1LE22013CC113AA GP T 230/460 GP10 Ball 1LE22013CD216AA GP T 575 GP10 Ball 1LE22013CD213AA GP TS 230/460 GP10 Ball 1LE22013BA216AA GP TS 575 GP10 Ball 1LE22013BA213AA GP T 230/460 GP10 Ball 1LE22013AB216AA GP T 575 GP10 Ball 1LE22013AB213AA GP T 230/460 GP10 Ball 1LE22013CC216AA GP T 575 GP10 Ball 1LE22013CC213AA GP TS 230/460 GP10 Ball 1LE22013DA116AA GP TS 575 GP10 Ball 1LE22013DA113AA GP T 230/460 GP10 Ball 1LE22013CB116AA GP T 575 GP10 Ball 1LE22013CB113AA GP T 230/460 GP10 Ball 1LE22014AC116AA GP T 575 GP10 Ball 1LE22014AC113AA GP TS 230/460 GP10 Ball 1LE22013DA216AA GP TS 575 GP10 Ball 1LE22013DA213AA GP T 230/460 GP10 Ball 1LE22013CB216AA GP T 575 GP10 Ball 1LE22013CB213AA GP T 230/460 GP10 Ball 1LE22014AC216AA GP T 575 GP10 Ball 1LE22014AC213AA GP TS 460 GP10 Ball 1LE22014BA212AA GP TS 575 GP10 Ball 1LE22014BA213AA GP T 460 GP10 Ball 1LE22014AB212AA GP TS 460 GP10 Ball 1LE22014BB212AA GP T 575 GP10 Ball 1LE22014AB213AA GP T 460 GP10 Roller 1LE22014CC112AA GP TS 460 GP10 Ball 1LE22014DC112AA GP T 575 GP10 Roller 1LE22014CC113AA GP Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Frames available after RGZP stock motors are depleted Stock Model DOE#CC032A

29 General Purpose - TEFC GP10 - (Cast Iron Frame) HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TS 460 GP10 Ball 1LE22014DA112AA GP TS 575 GP10 Ball 1LE22014DA113AA GP T 460 GP10 Roller 1LE22014CB112AA GP B444T 460 GP10 Ball 1LE22014EB112AA GP TS 460 GP10 Ball 1LE22014DB112AA GP T 575 GP10 Roller 1LE22014CB113AA GP B444T 575 GP10 Ball 1LE22014EB113AA GP TS 575 GP10 Ball 1LE22014DB113AA GP T 460 GP10 Roller 1LE22014CC212AA GP B445T 460 GP10 Ball 1LE22014EC212AA GP TS 460 GP10 Ball 1LE22014DC212AA GP T 575 GP10 Roller 1LE22014CC213AA GP B445T 575 GP10 Ball 1LE22014EC213AA GP TS 575 GP10 Ball 1LE22014DC213AA GP TS 460 GP10 Ball 1LE22014DA212AA GP TS 575 GP10 Ball 1LE22014DA213AA GP T 460 GP10 Roller 1LE22014CB212AA GP B445T 460 GP10 Ball 1LE22014EB212AA GP TS 460 GP10 Ball 1LE22014DB212AA GP T 575 GP10 Roller 1LE22014CB213AA GP B445T 575 GP10 Ball 1LE22014EB213AA GP TS 575 GP10 Ball 1LE22014DB213AA GP T 460 GP10 Roller 1LE22014CC312AA GP B447T 460 GP10 Ball 1LE22014EC312AA GP TS 460 GP10 Ball 1LE22014DC312AA GP T 575 GP10 Roller 1LE22014CC313AA GP B447T 575 GP10 Ball 1LE22014EC313AA GP TS 575 GP10 Ball 1LE22014DC313AA GP TS 460 GP10 Ball 1LE22014DA312AA GP TS 575 GP10 Ball 1LE22014DA313AA GP T 460 GP10 Roller 1LE22014CB312AA GP B447T 460 GP10 Ball 1LE22014EB312AA GP TS 460 GP10 Ball 1LE22014DB312AA GP T 575 GP10 Roller 1LE22014CB313AA GP B447T 575 GP10 Ball 1LE22014EB313AA GP TS 575 GP10 Ball 1LE22014DB313AA GP T 460 GP10 Roller 1LE22014CC512AA GP B449T 460 GP10 Ball 1LE22014EC512AA GP TS 460 GP10 Ball 1LE22014DC512AA GP T 575 GP10 Roller 1LE22014CC513AA GP B449T 575 GP10 Ball 1LE22014EC513AA GP TS 575 GP10 Ball 1LE22014DC513AA GP Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Frames available after RGZP stock motors are depleted DOE#CC032A Low Voltage AC Selection and Pricing Guide Stock Model 2-11 Introduction General Purpose Duty Duty Purpose Dimensions

30 Introduction General Purpose Duty Duty Purpose Dimensions General Purpose - TEFC GP10 - (Cast Iron Frame) HP RPM Frame Voltage Type C-Face, Horizontal, Foot Mounted DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TC /460 GP10 Ball 1LE22011AA114EA3 371 GP TC 575 GP10 Ball 1LE22011AA113EA3 371 GP TC /460 GP10 Ball 1LE22011AB214EA3 371 GP TC 575 GP10 Ball 1LE22011AB213EA3 371 GP TC /460 GP10 Ball 1LE22011AC314EA3 448 GP TC 575 GP10 Ball 1LE22011AC313EA3 448 GP TC /460 GP10 Ball 1LE22011CD114EA3 694 GP TC 575 GP10 Ball 1LE22011CD113EA3 694 GP TC /460 GP10 Ball 1LE22011AA214EA3 379 GP TC 575 GP10 Ball 1LE22011AA213EA3 379 GP TC /460 GP10 Ball 1LE22011AB314EA3 403 GP TC 575 GP10 Ball 1LE22011AB313EA3 403 GP TC /460 GP10 Ball 1LE22011CC114EA3 499 GP TC 575 GP10 Ball 1LE22011CC113EA3 499 GP TC /460 GP10 Ball 1LE22011CD314EA3 746 GP TC 575 GP10 Ball 1LE22011CD313EA3 746 GP TC /460 GP10 Ball 1LE22011AA314EA3 432 GP TC 575 GP10 Ball 1LE22011AA313EA3 432 GP TC /460 GP10 Ball 1LE22011AB414EA3 433 GP TC 575 GP10 Ball 1LE22011AB413EA3 433 GP TC /460 GP10 Ball 1LE22011CC314EA3 543 GP TC 575 GP10 Ball 1LE22011CC313EA3 543 GP TC /460 GP10 Ball 1LE22012AD114EA3 846 GP TC 575 GP10 Ball 1LE22012AD113EA3 846 GP TC /460 GP10 Ball 1LE22011CA114EA3 499 GP TC 575 GP10 Ball 1LE22011CA113EA3 499 GP TC /460 GP10 Ball 1LE22011CB114EA3 513 GP TC 575 GP10 Ball 1LE22011CB113EA3 513 GP TC /460 GP10 Ball 1LE22012AC114EA3 675 GP TC 575 GP10 Ball 1LE22012AC113EA3 675 GP TC /460 GP10 Ball 1LE22012AD214EA GP TC 575 GP10 Ball 1LE22012AD213EA GP TC /460 GP10 Ball 1LE22011CA314EA3 626 GP TC 575 GP10 Ball 1LE22011CA313EA3 626 GP TC /460 GP10 Ball 1LE22011CB314EA3 574 GP TC 575 GP10 Ball 1LE22011CB313EA3 574 GP TC /460 GP10 Ball 1LE22012AC214EA3 967 GP TC 575 GP10 Ball 1LE22012AC213EA3 967 GP TC /460 GP10 Ball 1LE22012BD114EA GP TC 575 GP10 Ball 1LE22012BD113EA GP Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Frames available after RGZP stock motors are depleted Stock Model Low Voltage AC Selection and Pricing Guide DOE#CC032A

31 General Purpose - TEFC GP10 - (Cast Iron Frame) HP RPM Frame Voltage Type C-Face, Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TC /460 GP10 Ball 1LE22012AA114EA3 793 GP TC 575 GP10 Ball 1LE22012AA113EA3 793 GP TC /460 GP10 Ball 1LE22012AB114EA3 771 GP TC 575 GP10 Ball 1LE22012AB113EA3 771 GP TC /460 GP10 Ball 1LE22012BC114EA GP TC 575 GP10 Ball 1LE22012BC113EA GP TC /460 GP10 Ball 1LE22012BD214EA GP TC 575 GP10 Ball 1LE22012BD213EA GP TC /460 GP10 Ball 1LE22012AA214EA3 921 GP TC 575 GP10 Ball 1LE22012AA213EA3 921 GP TC /460 GP10 Ball 1LE22012AB214EA3 921 GP TC 575 GP10 Ball 1LE22012AB213EA3 921 GP TC /460 GP10 Ball 1LE22012BC214EA GP TC 575 GP10 Ball 1LE22012BC213EA GP TC /460 GP10 Ball 1LE22012BA114EA GP TC 575 GP10 Ball 1LE22012BA113EA GP TC /460 GP10 Ball 1LE22012BB114EA GP TC 575 GP10 Ball 1LE22012BB113EA GP TC /460 GP10 Ball 1LE22012BA214EA GP TC 575 GP10 Ball 1LE22012BA213EA GP TC /460 GP10 Ball 1LE22012BB214EA GP TC 575 GP10 Ball 1LE22012BB213EA GP C-Face, Horizontal, Footless TC /460 GP10 Ball 1LE22011AA114GA3 386 GP TC 575 GP10 Ball 1LE22011AA113GA3 386 GP TC /460 GP10 Ball 1LE22011AB214GA3 386 GP TC 575 GP10 Ball 1LE22011AB213GA3 386 GP TC /460 GP10 Ball 1LE22011AC314GA3 463 GP TC 575 GP10 Ball 1LE22011AC313GA3 463 GP TC /460 GP10 Ball 1LE22011CD114GA3 718 GP TC 575 GP10 Ball 1LE22011CD113GA3 718 GP TC /460 GP10 Ball 1LE22011AA214GA3 393 GP TC 575 GP10 Ball 1LE22011AA213GA3 393 GP TC /460 GP10 Ball 1LE22011AB314GA3 418 GP TC 575 GP10 Ball 1LE22011AB313GA3 418 GP TC /460 GP10 Ball 1LE22011CC114GA3 523 GP TC 575 GP10 Ball 1LE22011CC113GA3 523 GP TC /460 GP10 Ball 1LE22011CD314GA3 770 GP TC 575 GP10 Ball 1LE22011CD313GA3 770 GP Stock Model Introduction General Purpose Duty Duty Purpose Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Frames available after RGZP stock motors are depleted DOE#CC032A Low Voltage AC Selection and Pricing Guide 2-13 Dimensions

32 Introduction General Purpose Duty Duty Purpose Dimensions General Purpose - TEFC GP10 - (Cast Iron Frame) HP RPM Frame Voltage Type C-Face, Horizontal, Footless - continued DE Bearing Low Voltage AC Selection and Pricing Guide List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TC /460 GP10 Ball 1LE22011AA314GA3 446 GP TC 575 GP10 Ball 1LE22011AA313GA3 446 GP TC /460 GP10 Ball 1LE22011AB414GA3 447 GP TC 575 GP10 Ball 1LE22011AB413GA3 447 GP TC /460 GP10 Ball 1LE22011CC314GA3 567 GP TC 575 GP10 Ball 1LE22011CC313GA3 567 GP TC /460 GP10 Ball 1LE22012AD114GA3 870 GP TC 575 GP10 Ball 1LE22012AD113GA3 870 GP TC /460 GP10 Ball 1LE22011CA114GA3 523 GP TC 575 GP10 Ball 1LE22011CA113GA3 523 GP TC /460 GP10 Ball 1LE22011CB114GA3 537 GP TC 575 GP10 Ball 1LE22011CB113GA3 537 GP TC /460 GP10 Ball 1LE22012AC114GA3 699 GP TC 575 GP10 Ball 1LE22012AC113GA3 699 GP TC /460 GP10 Ball 1LE22012AD214GA GP TC 575 GP10 Ball 1LE22012AD213GA GP TC /460 GP10 Ball 1LE22011CA314GA3 650 GP TC 575 GP10 Ball 1LE22011CA313GA3 650 GP TC /460 GP10 Ball 1LE22011CB314GA3 598 GP TC 575 GP10 Ball 1LE22011CB313GA3 598 GP TC /460 GP10 Ball 1LE22012AC214GA3 991 GP TC 575 GP10 Ball 1LE22012AC213GA3 991 GP TC /460 GP10 Ball 1LE22012BD114GA GP TC 575 GP10 Ball 1LE22012BD113GA GP TC /460 GP10 Ball 1LE22012AA114GA3 817 GP TC 575 GP10 Ball 1LE22012AA113GA3 817 GP TC /460 GP10 Ball 1LE22012AB114GA3 795 GP TC 575 GP10 Ball 1LE22012AB113GA3 795 GP TC /460 GP10 Ball 1LE22012BC114GA GP TC 575 GP10 Ball 1LE22012BC113GA GP TC /460 GP10 Ball 1LE22012BD214GA GP TC 575 GP10 Ball 1LE22012BD213GA GP TC /460 GP10 Ball 1LE22012AA214GA3 945 GP TC 575 GP10 Ball 1LE22012AA213GA3 945 GP TC /460 GP10 Ball 1LE22012AB214GA3 945 GP TC 575 GP10 Ball 1LE22012AB213GA3 945 GP TC /460 GP10 Ball 1LE22012BC214GA GP TC 575 GP10 Ball 1LE22012BC213GA GP TC /460 GP10 Ball 1LE22012BA114GA GP TC 575 GP10 Ball 1LE22012BA113GA GP TC /460 GP10 Ball 1LE22012BB114GA GP TC 575 GP10 Ball 1LE22012BB113GA GP TC /460 GP10 Ball 1LE22012BA214GA GP TC 575 GP10 Ball 1LE22012BA213GA GP TC /460 GP10 Ball 1LE22012BB214GA GP TC 575 GP10 Ball 1LE22012BB213GA GP Stock Model DOE#CC032A

33 General Purpose - TEFC RGZP (Cast Iron Frame) RGZP motors are ideal for both indoor and outdoor applications and in operating atmospheres that contain moisture, dust and grit. These industry workhorses are ideal for use in material handling, pump, fan, compressor and other general purpose applications. Specifications 25 to 200 HP 1.15 service factor, 40ºC ambient 3600, 1800, 1200 or 900 RPM 3-phase, 60 Hz; 230/460 volt operation under 100 HP, 460 volt 100 HP and above, 575 volt available Meets or exceeds EPAct efficiency standards Class F insulation, Class B temperature rise NEMA design B, continuous duty 284T through 449T frame Features for Long Life Frame & Bearing Housings Cast iron construction for exceptional structural integrity & corrosion resistance, equipped with integrally cast feet. Condensation T-drains provided. Lifting eyebolts are included. Rotor A unique rotor design provides improved efficiency. Large cross section bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel (C1045) shaft for maximum rotor performance. Specifications table begins on the next page Stator/Windings Manufactured with premium electrical-grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross-section reduces resistance and lowers stator losses. Insulation Proprietary, inverterrated, Class F non-hygroscopic insulation system with NEMA Class B temperature 1.0SF provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical shock. This insulation system meets or exceeds NEMA MG1-2006, Part 31, making all motors suitable for operation with adjustable frequency drives. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves air flow, reduces noise and provides dependable cooling. Polycarbonate fan covers are provided on 284T-365T frames and cast iron for frames 404T and larger. Bearings Oversized, regreasable, single shielded, with cast iron inner caps (444T 449T). Alemite grease fittings on the inlets and pipe plugs on the relief ports for ease of routine maintenance. For added bearing protection, motors are equipped with a drive end shaft V-ring slinger. High Efficiency Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. Oversized Conduit Box Larger than industry standards, diagonallysplit, gasketed and rotatable in 90 increments for quick and easy connections. Leads are non-wicking and are clearly and permanently marked. Steel construction for frames 284T to 405T and cast iron for 444T frames and larger. Corrosion Resistance Cast iron construction, zinc-plated hardware, epoxy enamel paint and aluminum nameplate resist rust and corrosion. Modifiable & Siemens motors are available with a wide variety of modifications and custom designs to meet your specific motor needs. Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 2-15 Dimensions

34 Introduction General Purpose Duty Duty Purpose Dimensions General Purpose - TEFC RGZP (Cast Iron Frame) HP RPM Frame Voltage Type DE Bearing List Price $ Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) T 230/460 RGZP Ball 1LE29312CC116AA SA-7ST T 575 RGZP Ball 1LE29312CC113AA SA-7ST T 230/460 RGZP Ball 1LE29312CC216AA SA-7ST T 575 RGZP Ball 1LE29312CC213AA SA-7ST TS 230/460 RGZP Ball 1LE29312DA116AA SA-7ST TS 575 RGZP Ball 1LE29312DA113AA SA-7ST T 230/460 RGZP Ball 1LE29312CB116AA SA-7ST T 575 RGZP Ball 1LE29312CB113AA SA-7ST T 230/460 RGZP Ball 1LE29313AC116AA SA-7ST T 575 RGZP Ball 1LE29313AC113AA SA-7ST TS 230/460 RGZP Ball 1LE29312DA216AA SA-7ST TS 575 RGZP Ball 1LE29312DA213AA SA-7ST T 230/460 RGZP Ball 1LE29312CB216AA SA-7ST T 575 RGZP Ball 1LE29312CB213AA SA-7ST T 230/460 RGZP Ball 1LE29313AC216AA SA-7ST T 575 RGZP Ball 1LE29313AC213AA SA-7ST TS 230/460 RGZP Ball 1LE29313BA116AA SA-7ST TS 575 RGZP Ball 1LE29313BA113AA SA-7ST T 230/460 RGZP Ball 1LE29313AB116AA SA-7ST T 575 RGZP Ball 1LE29313AB113AA SA-7ST T 230/460 RGZP Ball 1LE29313CC116AA SA-7ST T 575 RGZP Ball 1LE29313CC113AA SA-7ST TS 230/460 RGZP Ball 1LE29313BA216AA SA-7ST TS 575 RGZP Ball 1LE29313BA213AA SA-7ST T 230/460 RGZP Ball 1LE29313AB216AA SA-7ST T 575 RGZP Ball 1LE29313AB213AA SA-7ST T 230/460 RGZP Ball 1LE29313CC216AA SA-7ST T 575 RGZP Ball 1LE29313CC213AA SA-7ST TS 230/460 RGZP Ball 1LE29313DA116AA SA-7ST TS 575 RGZP Ball 1LE29313DA113AA SA-7ST T 230/460 RGZP Ball 1LE29313CB116AA SA-7ST T 575 RGZP Ball 1LE29313CB113AA SA-7ST T 230/460 RGZP Ball 1LE29314AC116AA SA-7ST T 575 RGZP Ball 1LE29314AC113AA SA-7ST TS 230/460 RGZP Ball 1LE29313DA216AA SA-7ST TS 575 RGZP Ball 1LE29313DA213AA SA-7ST High Efficiency T 230/460 RGZP Ball 1LE29313CB216AA SA-7ST T 575 RGZP Ball 1LE29313CB213AA SA-7ST T 230/460 RGZP Ball 1LE29314AC216AA SA-7ST T 575 RGZP Ball 1LE29314AC213AA SA-7ST Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V All RGZP motors will be discontinued when present stock is depleted Stock Model Low Voltage AC Selection and Pricing Guide DOE#CC032A

35 General Purpose - TEFC RGZP (Cast Iron Frame) HP RPM Frame Voltage Type DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TS 460 RGZP Ball 1LE29314BA212AA SA-7ST TS 575 RGZP Ball 1LE29314BA213AA SA-7ST T 460 RGZP Ball 1LE29314AB212AA SA-7ST TS 460 RGZP Ball 1LE29314BB212AA SA-7ST T 575 RGZP Ball 1LE29314AB213AA SA-7ST T 460 RGZP Roller 1LE29314CC112AA SA-7ST TS 460 RGZP Ball 1LE29314DC112AA SA-7ST T 575 RGZP Roller 1LE29314CC113AA SA-7ST TS 460 RGZP Ball 1LE29314DA112AA SA-7ST TS 575 RGZP Ball 1LE29314DA113AA SA-7ST T 460 RGZP Roller 1LE29314CB112AA SA-7ST B444T 460 RGZP Ball 1LE29314EB112AA SA-7ST TS 460 RGZP Ball 1LE29314DB112AA SA-7ST T 575 RGZP Roller 1LE29314CB113AA SA-7ST T 460 RGZP Roller 1LE29314CC212AA SA-7ST TS 460 RGZP Ball 1LE29314DC212AA SA-7ST T 575 RGZP Roller 1LE29314CC213AA SA-7ST TS 460 RGZP Ball 1LE29314DA212AA SA-7ST TS 575 RGZP Ball 1LE29314DA213AA SA-7ST T 460 RGZP Roller 1LE29314CB212AA SA-7ST B445T 460 RGZP Ball 1LE29314EB212AA SA-7ST TS 460 RGZP Ball 1LE29314DB212AA SA-7ST T 575 RGZP Roller 1LE29314CB213AA SA-7ST T 460 RGZP Roller 1LE29314CC312AA SA-7ST TS 460 RGZP Ball 1LE29314DC312AA SA-7ST T 575 RGZP Roller 1LE29314CC313AA SA-7ST TS 460 RGZP Ball 1LE29314DA312AA SA-7ST TS 575 RGZP Ball 1LE29314DA313AA SA-7ST T 460 RGZP Roller 1LE29314CB312AA SA-7ST TS 460 RGZP Ball 1LE29314DB312AA SA-7ST T 575 RGZP Roller 1LE29314CB313AA SA-7ST T 460 RGZP Roller 1LE29314CC512AA SA-7ST TS 460 RGZP Ball 1LE29314DC512AA SA-7ST T 575 RGZP Roller 1LE29314CC513AA SA-7ST Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V All RGZP motors will be discontinued when present stock is depleted Stock Model Introduction General Purpose Duty Duty Purpose DOE#CC032A Low Voltage AC Selection and Pricing Guide 2-17 Dimensions

36 Introduction General Purpose Duty Duty General Purpose - TEFC GP100A (Cast Aluminum Frame) GP100A general purpose TEFC motors are available in two configurations they exceed NEMA Premium efficiency with our exclusive, leading-edge, die cast copper rotor design or meet NEMA Premium efficiency with our die cast aluminum rotor design. Either way, these motors significantly reduce operating costs and pay for themselves in a short time through energy savings. These industry workhorses are ideal for use in material handling, pump, fan, compressor and other industrial applications. Specifications 1 to 20 HP 1.15 service factor, 40 C ambient 3600, 1800 or 1200 RPM 3 phase, 60 Hz; /460 and 575 volt operation Meets or exceeds NEMA Premium efficiency standards Class F insulation, Class B temperature 1.0SF NEMA Design B, Continuous Duty Meets IP54 143T through 256T frame Features for Long Life Frame & Bearing Housings Die cast aluminum construction for exceptional heat dissipation and structural integrity. Maximum mounting flexibility assured with bolt-on feet. Condensation drain holes provided. Integrally cast lifting eyes. Unique frame fin design maximizes cooling. Rotor Each rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel (C1045) shaft for maximum rotor performance. Stator/Windings Manufactured with premium electrical grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross section reduces resistance and lowers stator losses. Insulation Proprietary inverter rated NEMA Class F non-hygroscopic insulation system with Class B temperature 1.0SF, provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical surges. This insulation system meets or exceeds NEMA MG1-2006, Part 31, making all motors suitable for operation with adjustable frequency drives. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves air flow, reduces noise and provides dependable cooling. Polycarbonate fan covers are provided on all frame sizes. Bearings Lubricated for life, oversized, complete with external bearing protection. Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 NEMA Premium Efficiency Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. Oversized Conduit Box Cast aluminum construction that is larger than industry standards, diagonally split and rotatable in 90º increments for quick and easy connections. Ground lug included. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Die cast aluminum construction, polycarbonate fan and fan cover, zinc-plated hardware, epoxy enamel paint and aluminum nameplate resist corrosion. Modifiable Siemens GP100A motors are available with a variety of modifications and kits. Specifications table begins on the next page Dimensions Purpose Low Voltage AC Selection and Pricing Guide

37 General Purpose - TEFC GP100A (Cast Aluminum Frame - Aluminum Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted DE Bearing List Price $ Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) T /460 GP100A Ball 1LE21211AA114AA3 327 GPA T 575 GP100A Ball 1LE21211AA113AA3 327 GPA T /460 GP100A Ball 1LE21211AB214AA3 327 GPA T 575 GP100A Ball 1LE21211AB213AA3 327 GPA T /460 GP100A Ball 1LE21211AC314AA3 406 GPA T 575 GP100A Ball 1LE21211AC313AA3 406 GPA T /460 GP100A Ball 1LE21211AA214AA3 335 GPA T 575 GP100A Ball 1LE21211AA213AA3 335 GPA T /460 GP100A Ball 1LE21211AB314AA3 359 GPA T 575 GP100A Ball 1LE21211AB313AA3 359 GPA T /460 GP100A Ball 1LE21211CC114AA3 434 GPA T 575 GP100A Ball 1LE21211CC113AA3 434 GPA T /460 GP100A Ball 1LE21211AA314AA3 390 GPA T 575 GP100A Ball 1LE21211AA313AA3 390 GPA T /460 GP100A Ball 1LE21211AB414AA3 391 GPA T 575 GP100A Ball 1LE21211AB413AA3 391 GPA T /460 GP100A Ball 1LE21211CC314AA3 479 GPA T 575 GP100A Ball 1LE21211CC313AA3 479 GPA T /460 GP100A Ball 1LE21211CA114AA3 434 GPA T 575 GP100A Ball 1LE21211CA113AA3 434 GPA T /460 GP100A Ball 1LE21211CB114AA3 449 GPA T 575 GP100A Ball 1LE21211CB113AA3 449 GPA T /460 GP100A Ball 1LE21212AC114AA3 616 GPA T 575 GP100A Ball 1LE21212AC113AA3 616 GPA T /460 GP100A Ball 1LE21211CA314AA3 565 GPA T 575 GP100A Ball 1LE21211CA313AA3 565 GPA T /460 GP100A Ball 1LE21211CB314AA3 511 GPA T 575 GP100A Ball 1LE21211CB313AA3 511 GPA T /460 GP100A Ball 1LE21212AC214AA3 919 GPA T 575 GP100A Ball 1LE21212AC213AA3 919 GPA T /460 GP100A Ball 1LE21212AA114AA3 738 GPA T 575 GP100A Ball 1LE21212AA113AA3 738 GPA T /460 GP100A Ball 1LE21212AB114AA3 715 GPA T 575 GP100A Ball 1LE21212AB113AA3 715 GPA T /460 GP100A Ball 1LE21212BC114AA GPA T 575 GP100A Ball 1LE21212BC113AA GPA T /460 GP100A Ball 1LE21212AA214AA3 870 GPA T 575 GP100A Ball 1LE21212AA213AA3 870 GPA T /460 GP100A Ball 1LE21212AB214AA3 870 GPA T 575 GP100A Ball 1LE21212AB213AA3 870 GPA T /460 GP100A Ball 1LE21212BC214AA GPA T 575 GP100A Ball 1LE21212BC213AA GPA Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V DOE#CC032A Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 NEMA Premium Efficiency Low Voltage AC Selection and Pricing Guide Stock Model 2-19 Introduction General Purpose Duty Duty Purpose Dimensions

38 General Purpose - TEFC GP100A (Cast Aluminum Frame - Aluminum Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) T /460 GP100A Ball 1LE21212BA114AA GPA T 575 GP100A Ball 1LE21212BA113AA GPA T /460 GP100A Ball 1LE21212BB114AA GPA T 575 GP100A Ball 1LE21212BB113AA GPA T /460 GP100A Ball 1LE21212BA214AA GPA T 575 GP100A Ball 1LE21212BA213AA GPA T /460 GP100A Ball 1LE21212BB214AA GPA T 575 GP100A Ball 1LE21212BB213AA GPA Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 NEMA Premium Efficiency Stock Model Dimensions Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide DOE#CC032A

39 General Purpose - TEFC GP100A (Cast Aluminum Frame - Copper Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted DE Bearing NEMA Premium Efficiency Plus List Price $ Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) T /460 GP100A Ball 1LE21111AB214AA3 362 GPA T 575 GP100A Ball 1LE21111AB213AA3 362 GPA T /460 GP100A Ball 1LE21111AC314AA3 452 GPA T 575 GP100A Ball 1LE21111AC313AA3 452 GPA T /460 GP100A Ball 1LE21111AA214AA3 372 GPA T 575 GP100A Ball 1LE21111AA213AA3 372 GPA T /460 GP100A Ball 1LE21111AB314AA3 399 GPA T 575 GP100A Ball 1LE21111AB313AA3 399 GPA T /460 GP100A Ball 1LE21111AA314AA3 433 GPA T 575 GP100A Ball 1LE21111AA313AA3 433 GPA T /460 GP100A Ball 1LE21111AB414AA3 434 GPA T 575 GP100A Ball 1LE21111AB413AA3 434 GPA T /460 GP100A Ball 1LE21111CA114AA3 482 GPA T 575 GP100A Ball 1LE21111CA113AA3 482 GPA T /460 GP100A Ball 1LE21111CB114AA3 499 GPA T 575 GP100A Ball 1LE21111CB113AA3 499 GPA T /460 GP100A Ball 1LE21112AC114AA3 685 GPA T 575 GP100A Ball 1LE21112AC113AA3 685 GPA T /460 GP100A Ball 1LE21111CA314AA3 628 GPA T 575 GP100A Ball 1LE21111CA313AA3 628 GPA T /460 GP100A Ball 1LE21111CB314AA3 568 GPA T 575 GP100A Ball 1LE21111CB313AA3 568 GPA T /460 GP100A Ball 1LE21112AC214AA GPA T 575 GP100A Ball 1LE21112AC213AA GPA T /460 GP100A Ball 1LE21112AA114AA3 820 GPA T 575 GP100A Ball 1LE21112AA113AA3 820 GPA T /460 GP100A Ball 1LE21112AB114AA3 795 GPA T 575 GP100A Ball 1LE21112AB113AA3 795 GPA T /460 GP100A Ball 1LE21112BC114AA GPA T 575 GP100A Ball 1LE21112BC113AA GPA T /460 GP100A Ball 1LE21112AA214AA3 967 GPA T 575 GP100A Ball 1LE21112AA213AA3 967 GPA T /460 GP100A Ball 1LE21112AB214AA3 967 GPA T 575 GP100A Ball 1LE21112AB213AA3 967 GPA T /460 GP100A Ball 1LE21112BC214AA GPA T 575 GP100A Ball 1LE21112BC213AA GPA T /460 GP100A Ball 1LE21112BA114AA GPA T 575 GP100A Ball 1LE21112BA113AA GPA T /460 GP100A Ball 1LE21112BB114AA GPA T 575 GP100A Ball 1LE21112BB113AA GPA T /460 GP100A Ball 1LE21112BA214AA GPA T 575 GP100A Ball 1LE21112BA213AA GPA T /460 GP100A Ball 1LE21112BB214AA GPA T 575 GP100A Ball 1LE21112BB213AA GPA DOE#CC032A Exceeds Energy Independence & Security Act Efficiency Levels Low Voltage AC Selection and Pricing Guide Stock Model 2-21 Introduction General Purpose Duty Duty Purpose Dimensions

40 Introduction General Purpose Duty Duty General Purpose - TEFC GP100 (Cast Iron Frame) GP100 general purpose TEFC motors are available in two configurations they exceed NEMA Premium efficiency with our exclusive, leading-edge, die cast copper rotor design or meet NEMA Premium efficiency with our die cast aluminum rotor design. Either way, these motors significantly reduce operating costs and pay for themselves in a short time through energy savings. These industry workhorses are ideal for use in material handling, pump, fan, compressor and other industrial applications. Specifications 1 to 20 HP 1.15 service factor, 40 C ambient 3600, 1800 or 1200 RPM 3 phase, 60 Hz; /460 and 575 volt operation Meets or exceeds NEMA Premium efficiency standards Class F insulation, Class B temperature 1.0SF NEMA Design B, Continuous Duty Meets IP55 143T through 256T frame Features for Long Life Frame & Bearing Housings Cast iron construction for exceptional structural integrity, equipped with integrally cast feet. Condensation drain holes provided. Lifting eyebolts are included for frames 180T to 256T. Unique frame fin design maximizes cooling. Rotor Each rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel (C1045) shaft for maximum rotor performance. Stator/Windings Manufactured with premium electrical grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross section reduces resistance and lowers stator losses. Insulation Proprietary inverterrated NEMA Class F non-hygroscopic insulation system with Class B temperature 1.0 SF, provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical surges. This insulation system meets or exceeds NEMA MG1-2006, Part 31, making all motors suitable for operation with adjustable frequency drives. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves air flow, reduces noise and provides dependable cooling. Polycarbonate fan covers are provided on all frame sizes. Bearings Lubricated for life, oversized, complete with external bearing protection. Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 NEMA Premium Efficiency Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. Oversized Conduit Box Cast aluminum construction that is larger than industry standards, diagonallysplit and rotatable in 90º increments for quick and easy connections. A ground lug is included. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, polycarbonate fan, zinc plated hardware, epoxy enamel paint and stainless steel nameplate resist rust and corrosion. Modifiable & Siemens motors are available with a wide variety of modifications & custom designs to meet your specific motor needs. Specifications table begins on the next page Dimensions Purpose Low Voltage AC Selection and Pricing Guide

41 General Purpose - TEFC GP100 (Cast Iron Frame - Aluminum Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps FL Nom. Eff. (%) Weight (lbs) T /460 GP100 Ball 1LE22211AA114AA3 355 GP T 575 GP100 Ball 1LE22211AA113AA3 355 GP T /460 GP100 Ball 1LE22211AB214AA3 355 GP T 575 GP100 Ball 1LE22211AB213AA3 355 GP T /460 GP100 Ball 1LE22211AC314AA3 441 GP T 575 GP100 Ball 1LE22211AC313AA3 441 GP T /460 GP100 Ball 1LE22211AA214AA3 364 GP T 575 GP100 Ball 1LE22211AA213AA3 364 GP T /460 GP100 Ball 1LE22211AB314AA3 391 GP T 575 GP100 Ball 1LE22211AB313AA3 391 GP T /460 GP100 Ball 1LE22211CC114AA3 471 GP T 575 GP100 Ball 1LE22211CC113AA3 471 GP T /460 GP100 Ball 1LE22211AA314AA3 423 GP T 575 GP100 Ball 1LE22211AA313AA3 423 GP T /460 GP100 Ball 1LE22211AB414AA3 424 GP T 575 GP100 Ball 1LE22211AB413AA3 424 GP T /460 GP100 Ball 1LE22211CC314AA3 521 GP T 575 GP100 Ball 1LE22211CC313AA3 521 GP T /460 GP100 Ball 1LE22211CA114AA3 471 GP T 575 GP100 Ball 1LE22211CA113AA3 471 GP T /460 GP100 Ball 1LE22211CB114AA3 487 GP T 575 GP100 Ball 1LE22211CB113AA3 487 GP T /460 GP100 Ball 1LE22212AC114AA3 670 GP T 575 GP100 Ball 1LE22212AC113AA3 670 GP T /460 GP100 Ball 1LE22211CA314AA3 614 GP T 575 GP100 Ball 1LE22211CA313AA3 614 GP T /460 GP100 Ball 1LE22211CB314AA3 555 GP T 575 GP100 Ball 1LE22211CB313AA3 555 GP T /460 GP100 Ball 1LE22212AC214AA3 999 GP T 575 GP100 Ball 1LE22212AC213AA3 999 GP T /460 GP100 Ball 1LE22212AA114AA3 802 GP T 575 GP100 Ball 1LE22212AA113AA3 802 GP T /460 GP100 Ball 1LE22212AB114AA3 778 GP T 575 GP100 Ball 1LE22212AB113AA3 778 GP T /460 GP100 Ball 1LE22212BC114AA GP T 575 GP100 Ball 1LE22212BC113AA GP T /460 GP100 Ball 1LE22212AA214AA3 946 GP T 575 GP100 Ball 1LE22212AA213AA3 946 GP T /460 GP100 Ball 1LE22212AB214AA3 946 GP T 575 GP100 Ball 1LE22212AB213AA3 946 GP T /460 GP100 Ball 1LE22212BC214AA GP T 575 GP100 Ball 1LE22212BC213AA GP Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V DOE#CC032A Meets or Exceeds Energy Independence & Security Act Efficiency Levels Low Voltage AC Selection and Pricing Guide Stock Model 2-23 Introduction General Purpose Duty Duty Purpose Dimensions

42 Introduction General Purpose Duty Duty Purpose Dimensions General Purpose - TEFC GP100 (Cast Iron Frame - Aluminum Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) T /460 GP100 Ball 1LE22212BA114AA GP T 575 GP100 Ball 1LE22212BA113AA GP T /460 GP100 Ball 1LE22212BB114AA GP T 575 GP100 Ball 1LE22212BB113AA GP T /460 GP100 Ball 1LE22212BA214AA GP T 575 GP100 Ball 1LE22212BA213AA GP T /460 GP100 Ball 1LE22212BB214AA GP T 575 GP100 Ball 1LE22212BB213AA GP C-Face, Horizontal, Footless Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 NEMA Premium Efficiency TC /460 GP100 Ball 1LE22211AA114GA3 421 GP TC 575 GP100 Ball 1LE22211AA113GA3 421 GP TC /460 GP100 Ball 1LE22211AB214GA3 421 GP TC 575 GP100 Ball 1LE22211AB213GA3 421 GP TC /460 GP100 Ball 1LE22211AC314GA3 508 GP TC 575 GP100 Ball 1LE22211AC313GA3 508 GP TC /460 GP100 Ball 1LE22211AA214GA3 431 GP TC 575 GP100 Ball 1LE22211AA213GA3 431 GP TC /460 GP100 Ball 1LE22211AB314GA3 458 GP TC 575 GP100 Ball 1LE22211AB313GA3 458 GP TC /460 GP100 Ball 1LE22211CC114GA3 570 GP TC 575 GP100 Ball 1LE22211CC113GA3 570 GP TC /460 GP100 Ball 1LE22211AA314GA3 489 GP TC 575 GP100 Ball 1LE22211AA313GA3 489 GP TC /460 GP100 Ball 1LE22211AB414GA3 490 GP TC 575 GP100 Ball 1LE22211AB413GA3 490 GP TC /460 GP100 Ball 1LE22211CC314GA3 620 GP TC 575 GP100 Ball 1LE22211CC313GA3 620 GP TC /460 GP100 Ball 1LE22211CA114GA3 570 GP TC 575 GP100 Ball 1LE22211CA113GA3 570 GP TC /460 GP100 Ball 1LE22211CB114GA3 586 GP TC 575 GP100 Ball 1LE22211CB113GA3 586 GP TC /460 GP100 Ball 1LE22212AC114GA3 769 GP TC 575 GP100 Ball 1LE22212AC113GA3 769 GP TC /460 GP100 Ball 1LE22211CA314GA3 713 GP TC 575 GP100 Ball 1LE22211CA313GA3 713 GP TC /460 GP100 Ball 1LE22211CB314GA3 654 GP TC 575 GP100 Ball 1LE22211CB313GA3 654 GP TC /460 GP100 Ball 1LE22212AC214GA GP TC 575 GP100 Ball 1LE22212AC213GA GP TC /460 GP100 Ball 1LE22212AA114GA3 901 GP TC 575 GP100 Ball 1LE22212AA113GA3 901 GP TC /460 GP100 Ball 1LE22212AB114GA3 876 GP TC 575 GP100 Ball 1LE22212AB113GA3 876 GP TC /460 GP100 Ball 1LE22212BC114GA GP TC 575 GP100 Ball 1LE22212BC113GA GP Stock Model Low Voltage AC Selection and Pricing Guide DOE#CC032A

43 General Purpose - TEFC GP100 (Cast Iron Frame - Aluminum Rotor) HP RPM Frame Voltage Type C-Face, Horizontal, Footless - continued DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) TC /460 GP100 Ball 1LE22212AA214GA GP TC 575 GP100 Ball 1LE22212AA213GA GP TC /460 GP100 Ball 1LE22212AB214GA GP TC 575 GP100 Ball 1LE22212AB213GA GP TC /460 GP100 Ball 1LE22212BC214GA GP TC 575 GP100 Ball 1LE22212BC213GA GP TC /460 GP100 Ball 1LE22212BA114GA GP TC 575 GP100 Ball 1LE22212BA113GA GP TC /460 GP100 Ball 1LE22212BB114GA GP TC 575 GP100 Ball 1LE22212BB113GA GP TC /460 GP100 Ball 1LE22212BA214GA GP TC 575 GP100 Ball 1LE22212BA213GA GP TC /460 GP100 Ball 1LE22212BB214GA GP TC 575 GP100 Ball 1LE22212BB213GA GP Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Stock Model Introduction General Purpose Duty Duty Purpose DOE#CC032A Low Voltage AC Selection and Pricing Guide 2-25 Dimensions

44 Introduction General Purpose Duty Duty Purpose Dimensions General Purpose - TEFC GP100 (Cast Iron Frame - Copper Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted DE Bearing NEMA Premium Efficiency Plus List Price $ Low Voltage AC Selection and Pricing Guide DOE#CC032A Mult. Sym. Exceeds Energy Independence & Security Act Efficiency Levels 2010 FL Amps* FL Nom. Eff. (%) Weight (lbs) T /460 GP100 Ball 1LE22111AB214AA3 394 GP T 575 GP100 Ball 1LE22111AB213AA3 394 GP T /460 GP100 Ball 1LE22111AC314AA3 490 GP T 575 GP100 Ball 1LE22111AC313AA3 490 GP T /460 GP100 Ball 1LE22111AA214AA3 404 GP T 575 GP100 Ball 1LE22111AA213AA3 404 GP T /460 GP100 Ball 1LE22111AB314AA3 434 GP T 575 GP100 Ball 1LE22111AB313AA3 434 GP T /460 GP100 Ball 1LE22111AA314AA3 470 GP T 575 GP100 Ball 1LE22111AA313AA3 470 GP T /460 GP100 Ball 1LE22111AB414AA3 471 GP T 575 GP100 Ball 1LE22111AB413AA3 471 GP T /460 GP100 Ball 1LE22111CA114AA3 524 GP T 575 GP100 Ball 1LE22111CA113AA3 524 GP T /460 GP100 Ball 1LE22111CB114AA3 542 GP T 575 GP100 Ball 1LE22111CB113AA3 542 GP T /460 GP100 Ball 1LE22112AC114AA3 744 GP T 575 GP100 Ball 1LE22112AC113AA3 744 GP T /460 GP100 Ball 1LE22111CA314AA3 683 GP T 575 GP100 Ball 1LE22111CA313AA3 683 GP T /460 GP100 Ball 1LE22111CB314AA3 617 GP T 575 GP100 Ball 1LE22111CB313AA3 617 GP T /460 GP100 Ball 1LE22112AC214AA GP T 575 GP100 Ball 1LE22112AC213AA GP T /460 GP100 Ball 1LE22112AA114AA3 891 GP T 575 GP100 Ball 1LE22112AA113AA3 891 GP T /460 GP100 Ball 1LE22112AB114AA3 864 GP T 575 GP100 Ball 1LE22112AB113AA3 864 GP T /460 GP100 Ball 1LE22112BC114AA GP T 575 GP100 Ball 1LE22112BC113AA GP T /460 GP100 Ball 1LE22112AA214AA GP T 575 GP100 Ball 1LE22112AA213AA GP T /460 GP100 Ball 1LE22112AB214AA GP T 575 GP100 Ball 1LE22112AB213AA GP T /460 GP100 Ball 1LE22112BC214AA GP T 575 GP100 Ball 1LE22112BC213AA GP T /460 GP100 Ball 1LE22112BA114AA GP T 575 GP100 Ball 1LE22112BA113AA GP T /460 GP100 Ball 1LE22112BB114AA GP T 575 GP100 Ball 1LE22112BB113AA GP T /460 GP100 Ball 1LE22112BA214AA GP T 575 GP100 Ball 1LE22112BA213AA GP T /460 GP100 Ball 1LE22112BB214AA GP T 575 GP100 Ball 1LE22112BB213AA GP Prices and specifications are subject to change without notice Stock availability subject to sale Stock Model delivery for stocked motors only *FL Amps at 460V or 575V

45 General Purpose - TEFC GP100 (Cast Iron Frame - Copper Rotor) HP RPM Frame Voltage Type C-Face, Horizontal, Footless DOE#CC032A DE Bearing NEMA Premium Efficiency Plus List Price $ Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) TC /460 GP100 Ball 1LE22111AB214GA3 468 GP TC 575 GP100 Ball 1LE22111AB213GA3 468 GP TC /460 GP100 Ball 1LE22111AC314GA3 565 GP TC 575 GP100 Ball 1LE22111AC313GA3 565 GP TC /460 GP100 Ball 1LE22111AA214GA3 478 GP TC 575 GP100 Ball 1LE22111AA213GA3 478 GP TC /460 GP100 Ball 1LE22111AB314GA3 508 GP TC 575 GP100 Ball 1LE22111AB313GA3 508 GP TC /460 GP100 Ball 1LE22111AA314GA3 544 GP TC 575 GP100 Ball 1LE22111AA313GA3 544 GP TC /460 GP100 Ball 1LE22111AB414GA3 545 GP TC 575 GP100 Ball 1LE22111AB413GA3 545 GP TC /460 GP100 Ball 1LE22111CA114GA3 633 GP TC 575 GP100 Ball 1LE22111CA113GA3 633 GP TC /460 GP100 Ball 1LE22111CB114GA3 651 GP TC 575 GP100 Ball 1LE22111CB113GA3 651 GP TC /460 GP100 Ball 1LE22112AC114GA3 854 GP TC 575 GP100 Ball 1LE22112AC113GA3 854 GP TC /460 GP100 Ball 1LE22111CA314GA3 792 GP TC 575 GP100 Ball 1LE22111CA313GA3 792 GP TC /460 GP100 Ball 1LE22111CB314GA3 727 GP TC 575 GP100 Ball 1LE22111CB313GA3 727 GP TC /460 GP100 Ball 1LE22112AC214GA GP TC 575 GP100 Ball 1LE22112AC213GA GP TC /460 GP100 Ball 1LE22112AA114GA GP TC 575 GP100 Ball 1LE22112AA113GA GP TC /460 GP100 Ball 1LE22112AB114GA3 973 GP TC 575 GP100 Ball 1LE22112AB113GA3 973 GP TC /460 GP100 Ball 1LE22112BC114GA GP TC 575 GP100 Ball 1LE22112BC113GA GP TC /460 GP100 Ball 1LE22112AA214GA GP TC 575 GP100 Ball 1LE22112AA213GA GP TC /460 GP100 Ball 1LE22112AB214GA GP TC 575 GP100 Ball 1LE22112AB213GA GP TC /460 GP100 Ball 1LE22112BC214GA GP TC 575 GP100 Ball 1LE22112BC213GA GP TC /460 GP100 Ball 1LE22112BA114GA GP TC 575 GP100 Ball 1LE22112BA113GA GP TC /460 GP100 Ball 1LE22112BB114GA GP TC 575 GP100 Ball 1LE22112BB113GA GP TC /460 GP100 Ball 1LE22112BA214GA GP TC 575 GP100 Ball 1LE22112BA213GA GP TC /460 GP100 Ball 1LE22112BB214GA GP TC 575 GP100 Ball 1LE22112BB213GA GP Prices and specifications are subject to change without notice Stock availability subject to sale Exceeds Energy Independence & Security Act Efficiency Levels Low Voltage AC Selection and Pricing Guide Stock Model delivery for stocked motors only *FL Amps at 460V or 575V 2-27 Introduction General Purpose Duty Duty Purpose Dimensions

46 Introduction General Purpose Duty Duty Purpose Dimensions General Purpose (GP ) Description Type / Frame List Price Adder Per Frame ($) Order GP10A GP Code Code Pos GP100A GP Altitude / Ambient Rerate/Derate Y80 Z Assembly - Mounting & Terminal Box Position F F W-1 9+R1A 16+Z W-2 9+R2A 16+Z W-3 9+R3A 16+Z W-4 9+R4A 16+Z W W C C Bearings Sealed Ball bearings 1 L68 Z (except 2 pole, 360+ frames) Breathers & Drain Plugs T Drain SS L45 Z Crouse Hinds - UL Approved L46 Z Conduit Box - Main Orient 90 deg CCW J84 Z Orient 180 deg CCW J85 Z Orient 270 deg CCW J86 Z Conduit Box - Auxiliary for Thermostats Condulet to Main Box J12 Z Conduit Box - Auxiliary for Space Heaters Condulet to Main Box J52 Z Drip Cover Drip cover without vertical K33 Z lifting devices Export Packaging Sea Freight - Siemens Sandard B09 Z Flanged End Shields C-Face w/ Feet 2 E C-Face w/o Feet G D-Flange w/ Feet F Grounding Provision (tapped hole on L27 Z frame w/bolt) Hardware Stainless Steel L22 Z Lifting Eyebolt 3 L20 Z Standard std std std std std std std std std std Insulation Fungus Protection C07 Z For further details please refer to section 8 1 Sealed Ball not available for 2 pole motors with frames > C face with fee for 440 frames, only available with ball bearings 3 Lisfting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required. S Low Voltage AC Selection and Pricing Guide

47 General Purpose (GP ) Description Type / Frame List Price Adder Per Frame ($) Order GP10A GP Code Code Pos GP100A GP Leads / Terminal Blocks Burndy Hydent type YA K80 Z Sealed Leads K89 Z Lubrication Grease Fitting / L60 Z Pressure Relief Nameplate Extra M21 Z Division 2 4 M22 Z Change (Rerate/Derate) Y80 Z Auxiliary Y82 Z Protective Devices - Windings Thermostats, normally G closed, 2 per motor Rotation Arrow Bidirectional (not applicable K70 Z for uni-directional motors) Clockwise (facing ODE) K71 Z Counterclockwise K72 Z (facing ODE) Service Factor Rerate/Derate Y80 Z Shaft Seal Slinger & O Ring L76 Z (4, 6, 8 Pole only) Software Documentation in Spanish D05 Z Certificate of Compliance F00 Z Standard Transmittal F40 Z Standard Dimension Sheet F42 Z Conduit Box Dimension Sheet F44 Z Wiring Diagram F45 Z IOM F46 Z Renewal Parts F47 Z Sheets F49 Z F03 Z Space Heater 115V, Single Phase A40 Z V, Single Phase A41 Z V, Single Phase, Div 2 A42 Z V, Single Phase, Div 2 A44 Z For further details please refer to section 8 1 Sealed Ball not available for 2 pole motors with frames > C face with fee for 440 frames, only available with ball bearings 3 Lisfting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required. S449 Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 2-29 Dimensions

48 Introduction General Purpose General Purpose (GP ) Description Type / Frame List Price Adder Per Frame ($) Order GP10A GP Code Code Pos GP100A GP Testing Routine Test Report F10 Z Routine Test Report with F20 Z Vibration Test Voltage Single Voltage - 230V 11 12& HP (outside leads connection only) Single Voltage - 460V (outside leads connection only) 12 12& HP For further details please refer to section 8 1 Sealed Ball not available for 2 pole motors with frames > C face with fee for 440 frames, only available with ball bearings 3 Lisfting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required. S449 Dimensions Duty Duty Purpose Low Voltage AC Selection and Pricing Guide

49 General Purpose (RGZP ) Description Code Order Code Pos Type / Frame RGZP List Price Adder Per Frame ($) Altitude / Ambient Rerate/Derate Y80 Z Assembly - Mounting & Terminal Box Position F W-1 9+R1A 16+Z W-2 9+R2A 16+Z W-3 9+R3A 16+Z W-4 9+R4A 16+Z W W C C Bearings Sealed Ball bearings 1 L68 Z (except 2 pole, 360+ frames) Breathers and Drain Plugs T Drain SS L45 Z Crouse Hinds - UL Approved L46 Z Conduit Box - Main Orient 90 deg CCW J84 Z Orient 180 deg CCW J85 Z Orient 270 deg CCW J86 Z Conduit Box - Auxiliary for Thermostats Condulet to Main Box J12 Z Conduit Box - Auxiliary for Space Heaters Condulet to Main Box J52 Z Drip Cover Drip cover without vertical lifting devices K33 Z Export Packaging Sea Freight - Siemens Standard B09 Z Flanged End Shields C-Face with Feet 2 E Grounding Provision (tapped hole on frame w/bolt) L27 Z Hardware Stainless Steel L22 Z Lifting Eyebolt 3 L20 Z Standard 30 std std std std std std std std std std Insulation Fungus Protection C07 Z Leads / Terminal Blocks Burndy Hydent type YA K80 Z Sealed Leads K89 Z Lubrication Grease Fitting / Pressure Relief L60 Z S449 Introduction General Purpose Duty Duty Purpose For further details please refer to section 8 1 Sealed Ball bearings not available for 2 pole motors with frames > C face with feet for 440 frames, only available with ball bearings 3 Lifting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order Low Voltage AC Selection and Pricing Guide 2-31 Dimensions

50 Introduction General Purpose Duty Duty Purpose Dimensions General Purpose (RGZP ) Description Code Order Code Pos Type / Frame RGZP List Price Adder Per Frame ($) Nameplate Extra M21 Z Division 2 4 M22 Z Change (Rerate/Derate) Y80 Z Auxiliary Y82 Z Protective Devices - Windings Thermostats, normally closed, 2 per G motor Rotation Arrow Bidirectional K70 Z (not applicable for uni-directional motors) Clockwise (facing ODE) K71 Z Counterclockwise (facing ODE) K72 Z Service Factor Rerate/Derate Y80 Z Shaft Seal Slinger & O Ring (4, 6, 8 Pole only) L76 Z Inpro Seal / DE L79 Z Inpro Seal / ODE L80 Z Inpro Seal / Both Ends L81 Z Software Documentation in Spanish D05 Z Certificate of Compliance F00 Z Standard Transmittal F40 Z Standard Dimension Sheet F42 Z Conduit Box Dimension Sheet F44 Z Wiring Diagram F45 Z IOM F46 Z Renewal Parts F47 Z Sheets F49 Z F03 Z Space Heater 115V, Single Phase A40 Z V, Single Phase A41 Z V, Single Phase, Div 2 A42 Z V, Single Phase, Div 2 A44 Z Testing Routine Test Report F10 Z Routine Test Report with Vibration Test F20 Z Voltage Single Voltage - 230V 11 12&13 75HP (outside leads connection only) Single Voltage - 460V (outside leads connection only) 12 12&13 75HP For further details please refer to section 8 1 Sealed Ball bearings not available for 2 pole motors with frames > C face with feet for 440 frames, only available with ball bearings 3 Lifting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. S Low Voltage AC Selection and Pricing Guide

51 Options General Purpose (GP ) Description Type / Frame List Price Adder Per Frame ($) Order GP10A GP Code Code Pos GP100A GP Assembly - Mounting & Terminal Box Position W W Auxiliary Boxes 1 Auxiliary conduit box location (Digit 2) Condulet on main box J 0 Z side Condulet to main J 2 Z conduit box Auxiliary conduit box J 3 Z on main conduit box Condulet - opposite of J 4 Z main conduit box side Auxiliary box- opposite of main conduit box side J 5 Z Temperature Detector Device (Digit 1) Thermistors 0 Thermostats 1 KTY 84 Thermistor 2 Space heaters 5 Stator RTD s to auxiliary conduit box of opposite of main box side Balance Select the number that corresponds with the appropriate Temperature Detector Device to create your initial 3 digital ordering code. J Precision M69 Z Extra Precision M70 Z Bearings Insulated L66 Z Insulated - ODE only L67 Z Couplings er Supplied H10 Z Export Packaging Special B10 Z cf cf cf cf cf cf cf cf cf cf cf Fans Bronze M10 Z For further details please refer to section 9 1 Condulet or Auxiliary box to Main only available for GP motors when ordered with Cast Iron Terminal Box For availability on Flanges and End shields as Options see page 9-14 S449 Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 2-33 Dimensions

52 Introduction General Purpose Duty Duty Options General Purpose (GP ) Description Insulation Type / Frame List Price Adder Per Frame ($) Order GP10A GP Code Code Pos GP100A GP Class H C00 Z Vacuum Pressure Impregnation (VPI) C01 Z Moisture/Powerhouse C04 Z (extra dip & bake) Tropicalization Moisture C08 Z (extra dip & bake, fungus spray) Leads / Terminal Blocks Terminal Block - 3 lead K83 Z only Leads, Special Cable Y85 Z cf cf cf cf cf cf cf cf cf cf cf Length Lubrication Special Grease (High & L57 Z Low Temp) (Mobil 28) Special Grease (Mobilith L58 Z SHC 100) Paint Paint - 2 Part Epoxy N02 Z Standard Primer Only N03 Z Standard Paint, Special Y60 Z Color Special Paint, Special Color Y61 Z cf cf cf cf cf cf cf cf cf cf cf For further details please refer to section 9 1 Condulet or Auxiliary box to Main only available for GP motors when ordered with Cast Iron Terminal Box S449 Dimensions Purpose Low Voltage AC Selection and Pricing Guide

53 Options General Purpose (GP ) Description Type / Frame List Price Adder Per Frame ($) Order GP10A GP S449 Code Code Pos GP100A GP Protective Devices - Windings PTC thermistors, 3 B embedded temperature sensors for tripping PTC thermistors, 6 C embedded temperature sensors for alarm and tripping KTY84-130, 2 F embedded temperature sensors Thermocouples, J coil head Winding temperature protection, Stator RTD s (coil head, 1 per phase), 100Ω Platinum, complete with auxiliary box with terminal strip opposite to main box K Protective Devices - Bearings Bearing thermal A51 Z protection, Bearing RTDs with connection head and terminal block - both ends, 100Ω Platinum Shafts Carbon Steel (C4140) M57 Z Shaft DE Special to Y50 Z cf cf cf cf cf cf cf cf cf cf cf er Specifications Shaft ODE Special to Y51 Z cf cf cf cf cf cf cf cf cf cf cf er Specifications NEMA Standard Short M53 Z Shaft - ODE NEMA Standard Long Shaft - ODE M52 Z For further details please refer to section 9 1 Condulet or Auxiliary box to Main only available for GP motors when ordered with Cast Iron Terminal Box Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 2-35 Dimensions

54 Introduction General Purpose Options General Purpose (GP ) Description Type / Frame List Price Adder Per Frame ($) Order GP10A GP S449 Code Code Pos GP100A GP Software Nonstandard F43 Z Dimension Sheet er Specific F50 Z Sheets Special Calculated F07 Z Terminal Box - Main Cast Iron Instead of L01 Z Cast Aluminum or Steel Testing Routine Test Report F12 Z (Witnessed) Complete Test F15 Z Complete Test (Witnessed) F17 Z Calibration Test F27 Z S449 Electrical Duplicate- F36 Z (Routine Test) S449 Electrical Duplicate (Complete Test) F37 Z S Noise F30 Z S449 Noise (Witnessed) F32 Z S449 Routine Test Report with Vibration Test (Witnessed) Vertical Jacking Vertical Jacking Provision F22 Z S M39 Z For further details please refer to section 9 1 Condulet or Auxiliary box to Main only available for GP motors when ordered with Cast Iron Terminal Box Dimensions Duty Duty Purpose Low Voltage AC Selection and Pricing Guide

55 Options General Purpose (GP ) Description Voltage Special Voltage V Special Voltage V Part Winding Start - 200V, 60Hz Part Winding Start - 230V, 60Hz Part Winding Start - 460V, 60Hz Part Winding Start - 575V, 60Hz Wye Start - Delta Run - 200V, 60Hz Wye Start - Delta Run - 230V, 60Hz Wye Start - Delta Run - 460V, 60Hz Wye Start - Delta Run - 575V, 60Hz Type / Frame List Price Adder Per Frame ($) Order GP10A GP Code Code Pos GP100A GP M1Y 12,13+Z ,13+Z M2Y 20 12& & & & & & & & For further details please refer to section 9 1 Condulet or Auxiliary box to Main only available for GP motors when ordered with Cast Iron Terminal Box S449 Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 2-37 Dimensions

56 Notes Dimensions Introduction Purpose Duty Duty General Purpose Low Voltage AC Selection and Pricing Guide

57 - TEFC SD10 SD10 severe duty TEFC motors meets or exceeds EPAct efficiency standards. They are ideal for both indoor and outdoor applications and in severe operating atmospheres. These industry workhorses are for use in chemical processing, mining, foundry, pulp and paper, waste management and petro/chemical applications. Specifications 1 to 400 HP 1.15 service factor, 40ºC ambient 3600, 1800, 1200 & 900 RPM 3-phase, 60 Hz; /460 and 575 volt operation (143T 256T) 3-phase, 60 Hz; 230/460 volt operation under 25 HP, 460 volt 25 HP and above, 200 & 575 volt available (284T S449) Meets or exceeds EPAct efficiency standards Class F insulation, Class B temperature 1.0SF NEMA design B, continuous duty 143T to S449 frame Features for Long Life Frame & Bearing Housings Cast iron construction for exceptional structural integrity & corrosion resistance, equipped with integrally cast feet. Condensation T-drains are provided. Lifting eyebolts are included with motors > 75 lbs. Rotor A unique rotor design provides improved efficiency. Large cross section bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel (C1045) shaft for maximum rotor performance. Stator/Windings Manufactured with premium electrical-grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross-section reduces resistance and lowers stator losses. Insulation Proprietary inverter-rated Class F non-hygroscopic insulation system with NEMA Class B temperature 1.0SF provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical surges. This insulation system meets or exceeds NEMA MG1-2006, Part 31 making all motors suitable for operation with adjustable frequency drives. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves air flow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes. Bearings Regreasable, oversized double shielded (143T 256T) / single shielded (284T S449T) with cast iron inner caps. Alemite grease fittings on the inlets and pipe plugs on the relief ports for ease of routine maintenance. Frames 143T 256T are equipped with drive end and opposite drive end shaft V-ring slingers for added bearing protection. Provisions for Inpro/Seal bearing isolators are standard on both ends. Frames 284T S449 are equipped with a drive end shaft V-ring slinger. High Efficiency Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. Oversized Conduit Box Cast iron construction that is larger than industry standards, diagonally-split, neoprene gasketed and rotatable in 90º increments for quick and easy connections. A ground lug is included. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, polycarbonate fan, zincplated hardware, epoxy enamel paint and stainless steel nameplate resist rust and corrosion. Modifiable & Siemens motors are available with a wide variety of modifications and custom designs to meet your specific motor needs. Introduction General Purpose Duty Duty Purpose Specifications table begins on the next page Low Voltage AC Selection and Pricing Guide 3-1 Dimensions

58 Introduction General Purpose Duty Duty Purpose Dimensions - TEFC SD10 HP RPM Frame Voltage Type Horizontal, Foot Mounted DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) T /460 SD10 Ball 1LE23011AA114AA3 350 SD T 575 SD10 Ball 1LE23011AA113AA3 350 SD T /460 SD10 Ball 1LE23011AB214AA3 336 SD T 575 SD10 Ball 1LE23011AB213AA3 336 SD T /460 SD10 Ball 1LE23011AC314AA3 418 SD T 575 SD10 Ball 1LE23011AC313AA3 418 SD T /460 SD10 Ball 1LE23011CD114AA3 655 SD T 575 SD10 Ball 1LE23011CD113AA3 655 SD T /460 SD10 Ball 1LE23011AA214AA3 355 SD T 575 SD10 Ball 1LE23011AA213AA3 355 SD T /460 SD10 Ball 1LE23011AB314AA3 373 SD T 575 SD10 Ball 1LE23011AB313AA3 373 SD T /460 SD10 Ball 1LE23011CC114AA3 464 SD T 575 SD10 Ball 1LE23011CC113AA3 464 SD T /460 SD10 Ball 1LE23011CD314AA3 737 SD T 575 SD10 Ball 1LE23011CD313AA3 737 SD T /460 SD10 Ball 1LE23011AA314AA3 422 SD T 575 SD10 Ball 1LE23011AA313AA3 422 SD T /460 SD10 Ball 1LE23011AB414AA3 408 SD T 575 SD10 Ball 1LE23011AB413AA3 408 SD T /460 SD10 Ball 1LE23011CC314AA3 517 SD T 575 SD10 Ball 1LE23011CC313AA3 517 SD T /460 SD10 Ball 1LE23012AD114AA3 856 SD T 575 SD10 Ball 1LE23012AD113AA3 856 SD T /460 SD10 Ball 1LE23011CA114AA3 474 SD T 575 SD10 Ball 1LE23011CA113AA3 474 SD T /460 SD10 Ball 1LE23011CB114AA3 457 SD T 575 SD10 Ball 1LE23011CB113AA3 457 SD T /460 SD10 Ball 1LE23012AC114AA3 640 SD T 575 SD10 Ball 1LE23012AC113AA3 640 SD T /460 SD10 Ball 1LE23012AD214AA SD T 575 SD10 Ball 1LE23012AD213AA SD T /460 SD10 Ball 1LE23011CA314AA3 595 SD T 575 SD10 Ball 1LE23011CA313AA3 595 SD T /460 SD10 Ball 1LE23011CB314AA3 531 SD T 575 SD10 Ball 1LE23011CB313AA3 531 SD T /460 SD10 Ball 1LE23012AC214AA3 917 SD T 575 SD10 Ball 1LE23012AC213AA3 917 SD T /460 SD10 Ball 1LE23012BD114AA SD T 575 SD10 Ball 1LE23012BD113AA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only Stock Model *FL Amps at 460V or 575V Frames available after RGZESD stock motors are depleted 1 CW Rotation facing opposite drive end Low Voltage AC Selection and Pricing Guide DOE#CC032A

59 - TEFC SD10 HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) T /460 SD10 Ball 1LE23012AA114AA3 736 SD T 575 SD10 Ball 1LE23012AA113AA3 736 SD T /460 SD10 Ball 1LE23012AB114AA3 726 SD T 575 SD10 Ball 1LE23012AB113AA3 726 SD T /460 SD10 Ball 1LE23012BC114AA SD T 575 SD10 Ball 1LE23012BC113AA SD T /460 SD10 Ball 1LE23012BD214AA SD T 575 SD10 Ball 1LE23012BD213AA SD T /460 SD10 Ball 1LE23012AA214AA3 863 SD T 575 SD10 Ball 1LE23012AA213AA3 863 SD T /460 SD10 Ball 1LE23012AB214AA3 877 SD T 575 SD10 Ball 1LE23012AB213AA3 877 SD T /460 SD10 Ball 1LE23012BC214AA SD T 575 SD10 Ball 1LE23012BC213AA SD T 230/460 SD10 Ball 1LE23012CD116AA SD T 575 SD10 Ball 1LE23012CD113AA SD T /460 SD10 Ball 1LE23012BA114AA SD T 575 SD10 Ball 1LE23012BA113AA SD T /460 SD10 Ball 1LE23012BB114AA SD T 575 SD10 Ball 1LE23012BB113AA SD T 230/460 SD10 Ball 1LE23012CC116AA SD T 575 SD10 Ball 1LE23012CC113AA SD T 230/460 SD10 Ball 1LE23012CD216AA SD T 575 SD10 Ball 1LE23012CD213AA SD T /460 SD10 Ball 1LE23012BA214AA SD T 575 SD10 Ball 1LE23012BA213AA SD T /460 SD10 Ball 1LE23012BB214AA SD T 575 SD10 Ball 1LE23012BB213AA SD T 230/460 SD10 Ball 1LE23012CC216AA SD T 575 SD10 Ball 1LE23012CC213AA SD T 230/460 SD10 Ball 1LE23013AD116AA SD T 575 SD10 Ball 1LE23013AD113AA SD T 460 SD10 Ball 1LE23012CA112AA SD TS 460 SD10 Ball 1LE23012DA112AA SD TS 575 SD10 Ball 1LE23012DA113AA SD T 460 SD10 Ball 1LE23012CB112AA SD TS 460 SD10 Ball 1LE23012DB112AA SD T 575 SD10 Ball 1LE23012CB113AA SD T 460 SD10 Ball 1LE23013AC112AA SD T 575 SD10 Ball 1LE23013AC113AA SD T 460 SD10 Ball 1LE23013AD212AA SD T 575 SD10 Ball 1LE23013AD213AA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only DOE#CC032A High Efficiency Low Voltage AC Selection and Pricing Guide Stock Model *FL Amps at 460V or 575V Frames available after RGZESD stock motors are depleted 1 CW Rotation facing opposite drive end 3-3 Introduction General Purpose Duty Duty Purpose Dimensions

60 Introduction General Purpose Duty Duty Purpose Dimensions - TEFC SD10 HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) T 460 SD10 Ball 1LE23012CA212AA SD TS 460 SD10 Ball 1LE23012DA212AA SD TS 575 SD10 Ball 1LE23012DA213AA SD T 460 SD10 Ball 1LE23012CB212AA SD TS 460 SD10 Ball 1LE23012DB212AA SD T 575 SD10 Ball 1LE23012CB213AA SD T 460 SD10 Ball 1LE23013AC212AA SD T 575 SD10 Ball 1LE23013AC213AA SD T 460 SD10 Ball 1LE23013CD112AA SD T 575 SD10 Ball 1LE23013CD113AA SD T 460 SD10 Ball 1LE23013AA112AA SD TS 460 SD10 Ball 1LE23013BA112AA SD TS 575 SD10 Ball 1LE23013BA113AA SD T 460 SD10 Ball 1LE23013AB112AA SD TS 460 SD10 Ball 1LE23013BB112AA SD T 575 SD10 Ball 1LE23013AB113AA SD T 460 SD10 Ball 1LE23013CC112AA SD T 575 SD10 Ball 1LE23013CC113AA SD T 460 SD10 Ball 1LE23013CD212AA SD T 575 SD10 Ball 1LE23013CD213AA SD T 460 SD10 Ball 1LE23013AA212AA SD TS 460 SD10 Ball 1LE23013BA212AA SD TS 575 SD10 Ball 1LE23013BA213AA SD T 460 SD10 Ball 1LE23013AB212AA SD TS 460 SD10 Ball 1LE23013BB212AA SD T 575 SD10 Ball 1LE23013AB213AA SD T 460 SD10 Ball 1LE23013CC212AA SD T 575 SD10 Ball 1LE23013CC213AA SD T 460 SD10 Ball 1LE23014AD112AA SD T 575 SD10 Ball 1LE23014AD113AA SD T 460 SD10 Ball 1LE23013CA112AA SD TS 460 SD10 Ball 1LE23013DA112AA SD TS 575 SD10 Ball 1LE23013DA113AA SD T 460 SD10 Ball 1LE23013CB112AA SD TS 460 SD10 Ball 1LE23013DB112AA SD T 575 SD10 Ball 1LE23013CB113AA SD T 460 SD10 Ball 1LE23014AC112AA SD T 575 SD10 Ball 1LE23014AC113AA SD T 460 SD10 Ball 1LE23014AD212AA SD T 575 SD10 Ball 1LE23014AD213AA SD T 460 SD10 Roller 1LE23014CE112AA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only Stock Model *FL Amps at 460V or 575V Frames available after RGZESD stock motors are depleted 1 CW Rotation facing opposite drive end Low Voltage AC Selection and Pricing Guide DOE#CC032A

61 - TEFC SD10 HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) T 460 SD10 Ball 1LE23013CA212AA SD TS 460 SD10 Ball 1LE23013DA212AA SD TS 575 SD10 Ball 1LE23013DA213AA SD T 460 SD10 Ball 1LE23013CB212AA SD TS 460 SD10 Ball 1LE23013DB212AA SD T 575 SD10 Ball 1LE23013CB213AA SD T 460 SD10 Ball 1LE23014AC212AA SD T 575 SD10 Ball 1LE23014AC213AA SD T 460 SD10 Roller 1LE23014CD112AA SD B444T 460 SD10 Ball 1LE23014ED112AA SD TS 460 SD10 Ball 1LE23014DD112AA SD T 575 SD10 Roller 1LE23014CD113AA SD B444T 575 SD10 Ball 1LE23014ED113AA SD TS 575 SD10 Ball 1LE23014DD113AA SD T 460 SD10 Roller 1LE23014CE212AA SD TS 460 SD10 Ball 1LE23014BA212AA SD TS 575 SD10 Ball 1LE23014BA213AA SD TS 460 SD10 Ball 1LE23014BB212AA SD T 460 SD10 Ball 1LE23014AB212AA SD T 575 SD10 Ball 1LE23014AB213AA SD T 460 SD10 Roller 1LE23014CC112AA SD B444T 460 SD10 Ball 1LE23014EC112AA SD TS 460 SD10 Ball 1LE23014DC112AA SD T 575 SD10 Roller 1LE23014CC113AA SD B444T 575 SD10 Ball 1LE23014EC113AA SD TS 575 SD10 Ball 1LE23014DC113AA SD T 460 SD10 Roller 1LE23014CD212AA SD B445T 460 SD10 Ball 1LE23014ED212AA SD TS 460 SD10 Ball 1LE23014DD212AA SD T 575 SD10 Roller 1LE23014CD213AA SD B445T 575 SD10 Ball 1LE23014ED213AA SD TS 575 SD10 Ball 1LE23014DD213AA SD T 460 SD10 Roller 1LE23014CE312AA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Frames available after RGZESD stock motors are depleted 1 CW Rotation facing opposite drive end High Efficiency Stock Model Introduction General Purpose Duty Duty Purpose DOE#CC032A Low Voltage AC Selection and Pricing Guide 3-5 Dimensions

62 Introduction General Purpose Duty Duty Purpose Dimensions - TEFC SD10 HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TS 460 SD10 Ball 1LE23014DA112AA SD TS 575 SD10 Ball 1LE23014DA113AA SD TS 460 SD10 Ball 1LE23014DB112AA SD B444T 460 SD10 Ball 1LE23014EB112AA SD T 460 SD10 Roller 1LE23014CB112AA SD TS 575 SD10 Ball 1LE23014DB113AA SD T 575 SD10 Roller 1LE23014CB113AA SD B444T 575 SD10 Ball 1LE23014EB113AA SD B445T 460 SD10 Ball 1LE23014EC212AA SD TS 460 SD10 Ball 1LE23014DC212AA SD T 460 SD10 Roller 1LE23014CC212AA SD T 575 SD10 Roller 1LE23014CC213AA SD B445T 575 SD10 Ball 1LE23014EC213AA SD TS 575 SD10 Ball 1LE23014DC213AA SD T 460 SD10 Roller 1LE23014CD312AA SD B447T 460 SD10 Ball 1LE23014ED312AA SD TS 460 SD10 Ball 1LE23014DD312AA SD T 575 SD10 Roller 1LE23014CD313AA SD TS 575 SD10 Ball 1LE23014DD313AA SD B447T 575 SD10 Ball 1LE23014ED313AA SD T 460 SD10 Roller 1LE23014CE512AA SD TS 460 SD10 Ball 1LE23014DA212AA SD TS 575 SD10 Ball 1LE23014DA213AA SD TS 460 SD10 Ball 1LE23014DB212AA SD B445T 460 SD10 Ball 1LE23014EB212AA SD T 460 SD10 Roller 1LE23014CB212AA SD TS 575 SD10 Ball 1LE23014DB213AA SD T 575 SD10 Roller 1LE23014CB213AA SD B445T 575 SD10 Ball 1LE23014EB213AA SD T 460 SD10 Roller 1LE23014CC312AA SD B447T 460 SD10 Ball 1LE23014EC312AA SD TS 460 SD10 Ball 1LE23014DC312AA SD T 575 SD10 Roller 1LE23014CC313AA SD B447T 575 SD10 Ball 1LE23014EC313AA SD TS 575 SD10 Ball 1LE23014DC313AA SD T 460 SD10 Roller 1LE23014CD412AA SD B447T 460 SD10 Ball 1LE23014ED412AA SD TS 460 SD10 Ball 1LE23014DD412AA SD T 575 SD10 Roller 1LE23014CD413AA SD B447T 575 SD10 Ball 1LE23014ED413AA SD TS 575 SD10 Ball 1LE23014DD413AA SD T 460 SD10 Roller 1LE23014CE612AA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only Stock Model *FL Amps at 460V or 575V Frames available after RGZESD stock motors are depleted 1 CW Rotation facing opposite drive end Low Voltage AC Selection and Pricing Guide DOE#CC032A

63 - TEFC SD10 HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) TS 460 SD10 Ball 1LE23014DA312AA SD TS 575 SD10 Ball 1LE23014DA313AA SD B447T 460 SD10 Ball 1LE23014EB312AA SD TS 460 SD10 Ball 1LE23014DB312AA SD T 460 SD10 Roller 1LE23014CB312AA SD TS 575 SD10 Ball 1LE23014DB313AA SD T 575 SD10 Roller 1LE23014CB313AA SD B447T 575 SD10 Ball 1LE23014EB313AA SD T 460 SD10 Roller 1LE23014CC512AA SD B449T 460 SD10 Ball 1LE23014EC512AA SD TS 460 SD10 Ball 1LE23014DC512AA SD T 575 SD10 Roller 1LE23014CC513AA SD B449T 575 SD10 Ball 1LE23014EC513AA SD TS 575 SD10 Ball 1LE23014DC513AA SD T 460 SD10 Roller 1LE23014CD612AA SD B449T 460 SD10 Ball 1LE23014ED612AA SD TS 460 SD10 Ball 1LE23014DD612AA SD T 575 SD10 Roller 1LE23014CD613AA SD B449T 575 SD10 Ball 1LE23014ED613AA SD TS 575 SD10 Ball 1LE23014DD613AA SD TS 460 SD10 Ball 1LE23014DA512AA SD TS 575 SD10 Ball 1LE23014DA513AA SD TS 460 SD10 Ball 1LE23014DB512AA SD B449T 460 SD10 Ball 1LE23014EB512AA SD T 460 SD10 Roller 1LE23014CB512AA SD T 575 SD10 Roller 1LE23014CB513AA SD B449T 575 SD10 Ball 1LE23014EB513AA SD TS 575 SD10 Ball 1LE23014DB513AA SD B449T 460 SD10 Ball 1LE23014EC612AA SD TS 460 SD10 Ball 1LE23014DC612AA SD T 460 SD10 Roller 1LE23014CC612AA SD T 575 SD10 Roller 1LE23014CC613AA SD B449T 575 SD10 Ball 1LE23014EC613AA SD TS 575 SD10 Ball 1LE23014DC613AA SD S449LS 460 SD10 Roller 1LE23014FD212AA SD S449LS 575 SD10 Ball 1LE23014FD213AA SD TS 460 SD10 Ball 1LE23014DA612AA SD TS 575 SD10 Ball 1LE23014DA613AA SD TS 460 SD10 Ball 1LE23014DB612AA SD T 460 SD10 Roller 1LE23014CB612AA SD B449T 460 SD10 Ball 1LE23014EB612AA SD T 575 SD10 Ball 1LE23014CB613AA SD B449T 575 SD10 Ball 1LE23014EB613AA SD TS 575 SD10 Ball 1LE23014DB613AA SD S449LS 460 SD10 Roller 1LE23014FC112AA SD S449LS 575 SD10 Ball 1LE23014FC113AA SD DOE#CC032A High Efficiency Low Voltage AC Selection and Pricing Guide Stock Model 3-7 Introduction General Purpose Duty Duty Purpose Dimensions

64 Introduction General Purpose Duty Duty Purpose Dimensions - TEFC SD10 HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) S449SS 460 SD10 Ball 1 1LE23014GA112AA SD S449SS 575 SD10 Ball 1LE23014GA113AA SD S449SS 460 SD10 Ball 1LE23014GB212AA SD S449LS 460 SD10 Roller 1LE23014FB212AA SD S449LS 575 SD10 Ball 1LE23014FB213AA SD S449LS 460 SD10 Roller 1LE23014FC312AA SD S449LS 575 SD10 Ball 1LE23014FC313AA SD S449SS 460 SD10 Ball 1 1LE23014GA312AA SD S449SS 575 SD10 Ball 1LE23014GA313AA SD S449SS 460 SD10 Ball 1LE23014GB312AA SD S449LS 460 SD10 Roller 1LE23014FB312AA SD S449LS 575 SD10 Ball 1LE23014FB313AA SD **S449LS 460 SD10 Roller 1LE23014FC412AA SD **S449LS 575 SD10 Ball 1LE23014FC413AA SD C-Face, Horizontal, Footless High Efficiency TC /460 SD10 Ball 1LE23011AA114GA3 417 SD TC 575 SD10 Ball 1LE23011AA113GA3 417 SD TC /460 SD10 Ball 1LE23011AB214GA3 403 SD TC 575 SD10 Ball 1LE23011AB213GA3 403 SD TC /460 SD10 Ball 1LE23011AC314GA3 485 SD TC 575 SD10 Ball 1LE23011AC313GA3 485 SD TC /460 SD10 Ball 1LE23011CD114GA3 754 SD TC 575 SD10 Ball 1LE23011CD113GA3 754 SD TC /460 SD10 Ball 1LE23011AA214GA3 422 SD TC 575 SD10 Ball 1LE23011AA213GA3 422 SD TC /460 SD10 Ball 1LE23011AB314GA3 440 SD TC 575 SD10 Ball 1LE23011AB313GA3 440 SD TC /460 SD10 Ball 1LE23011CC114GA3 563 SD TC 575 SD10 Ball 1LE23011CC113GA3 563 SD TC /460 SD10 Ball 1LE23011CD314GA3 836 SD TC 575 SD10 Ball 1LE23011CD313GA3 836 SD TC /460 SD10 Ball 1LE23011AA314GA3 489 SD TC 575 SD10 Ball 1LE23011AA313GA3 489 SD TC /460 SD10 Ball 1LE23011AB414GA3 475 SD TC 575 SD10 Ball 1LE23011AB413GA3 475 SD TC /460 SD10 Ball 1LE23011CC314GA3 616 SD TC 575 SD10 Ball 1LE23011CC313GA3 616 SD TC /460 SD10 Ball 1LE23012AD114GA3 955 SD TC 575 SD10 Ball 1LE23012AD113GA3 955 SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V **Available only with Service Factor 1.0 and NEMA design A. Frames available after RGZESD stock motors are depleted 1 CW Rotation facing opposite drive end Stock Model Low Voltage AC Selection and Pricing Guide DOE#CC032A

65 - TEFC SD10 HP RPM Frame Voltage Type C-Face, Horizontal, Footless - continued DE Bearing List Price $ Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) TC /460 SD10 Ball 1LE23011CA114GA3 573 SD TC 575 SD10 Ball 1LE23011CA113GA3 573 SD TC /460 SD10 Ball 1LE23011CB114GA3 556 SD TC 575 SD10 Ball 1LE23011CB113GA3 556 SD TC /460 SD10 Ball 1LE23012AC114GA3 739 SD TC 575 SD10 Ball 1LE23012AC113GA3 739 SD TC /460 SD10 Ball 1LE23012AD214GA SD TC 575 SD10 Ball 1LE23012AD213GA SD TC /460 SD10 Ball 1LE23011CA314GA3 694 SD TC 575 SD10 Ball 1LE23011CA313GA3 694 SD TC /460 SD10 Ball 1LE23011CB314GA3 630 SD TC 575 SD10 Ball 1LE23011CB313GA3 630 SD TC /460 SD10 Ball 1LE23012AC214GA SD TC 575 SD10 Ball 1LE23012AC213GA SD TC /460 SD10 Ball 1LE23012BD114GA SD TC 575 SD10 Ball 1LE23012BD113GA SD TC /460 SD10 Ball 1LE23012AA114GA3 835 SD TC 575 SD10 Ball 1LE23012AA113GA3 835 SD TC /460 SD10 Ball 1LE23012AB114GA3 825 SD TC 575 SD10 Ball 1LE23012AB113GA3 825 SD TC /460 SD10 Ball 1LE23012BC114GA SD TC 575 SD10 Ball 1LE23012BC113GA SD TC /460 SD10 Ball 1LE23012BD214GA SD TC 575 SD10 Ball 1LE23012BD213GA SD TC /460 SD10 Ball 1LE23012AA214GA3 962 SD TC 575 SD10 Ball 1LE23012AA213GA3 962 SD TC /460 SD10 Ball 1LE23012AB214GA3 976 SD TC 575 SD10 Ball 1LE23012AB213GA3 976 SD TC /460 SD10 Ball 1LE23012BC214GA SD TC 575 SD10 Ball 1LE23012BC213GA SD TC /460 SD10 Ball 1LE23012BA114GA SD TC 575 SD10 Ball 1LE23012BA113GA SD TC /460 SD10 Ball 1LE23012BB114GA SD TC 575 SD10 Ball 1LE23012BB113GA SD TC /460 SD10 Ball 1LE23012BA214GA SD TC 575 SD10 Ball 1LE23012BA213GA SD TC /460 SD10 Ball 1LE23012BB214GA SD TC 575 SD10 Ball 1LE23012BB213GA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Frames available after RGZESD stock motors are depleted 1 CW Rotation facing opposite drive end DOE#CC032A High Efficiency Low Voltage AC Selection and Pricing Guide Stock Model 3-9 Introduction General Purpose Duty Duty Purpose Dimensions

66 Introduction General Purpose Duty Duty - TEFC RGZESD RGZESD motors are ideal for both indoor and outdoor applications and in operating atmospheres that contain moisture, dust and grit. These industry workhorses are ideal for use in material handling, pump, fan, compressor and other general purpose applications. Specifications 25 to 400 HP 1.15 service factor, 40ºC ambient 3600, 1800, 1200 or 900 RPM 3-phase, 60 Hz; 230/460 volt operation under 100 HP, 460 volt 100 HP and above, 575 volt available Meets or exceeds EPAct efficiency standards Class F insulation, Class B temperature rise NEMA design B, continuous duty 284T through 449T frame Features for Long Life Frame & Bearing Housings Cast iron construction for exceptional structural integrity & corrosion resistance, equipped with integrally cast feet. Condensation T-drains provided. Lifting eyebolts are included for frames > 75 lbs. Rotor A unique rotor design provides improved efficiency while larger bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel (C1045) shaft for maximum rotor performance. Specifications table begins on the next page Stator/Windings Manufactured with premium electrical grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross section reduces resistance and lowers stator losses. Insulation Proprietary inverter rated NEMA Class F non-hygroscopic insulation system with Class B temperature rise, provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical surges This insulation system meets or exceeds NEMA MG1-2006, Part 31 making all motors suitable for operation with adjustable speed drives. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves airflow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes Bearings Regreasable, oversized single shielded with cast iron inner caps. Alemite grease fittings on the inlets and pipe plugs on the relief ports for ease of routine maintenance. For added bearing protection, a drive end shaft V-ring slinger is provided. Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. High Efficiency Oversized Conduit Box Cast iron construction that is larger than industry standards, diagonally-split, neoprene gasketed and rotatable in 90º increments for quick and easy connections. A ground lug is included. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, zinc-plated hardware, epoxy enamel paint and stainless steel nameplate resist rust and corrosion. Modifiable & All Siemens motors are available with a wide variety of modifications and custom designs to meet your specific motor needs. Dimensions Purpose Low Voltage AC Selection and Pricing Guide

67 - TEFC RGZESD HP RPM Frame Voltage Type DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) T 230/460 RGZESD Ball 1LE29512CD116AA SA-7XSD T 575 RGZESD Ball 1LE29512CD113AA SA-7XSD T 230/460 RGZESD Ball 1LE29512CC116AA SA-7XSD T 575 RGZESD Ball 1LE29512CC113AA SA-7XSD T 230/460 RGZESD Ball 1LE29512CD216AA SA-7XSD T 575 RGZESD Ball 1LE29512CD213AA SA-7XSD T 230/460 RGZESD Ball 1LE29512CC216AA SA-7XSD T 575 RGZESD Ball 1LE29512CC213AA SA-7XSD T 230/460 RGZESD Ball 1LE29513AD116AA SA-7XSD T 575 RGZESD Ball 1LE29513AD113AA SA-7XSD T 460 RGZESD Ball 1LE29512CA112AA SA-7XSD TS 460 RGZESD Ball 1LE29512DA112AA SA-7XSD TS 575 RGZESD Ball 1LE29512DA113AA SA-7XSD T 460 RGZESD Ball 1LE29512CB112AA SA-7XSD TS 460 RGZESD Ball 1LE29512DB112AA SA-7XSD T 575 RGZESD Ball 1LE29512CB113AA SA-7XSD T 460 RGZESD Ball 1LE29513AC112AA SA-7XSD T 575 RGZESD Ball 1LE29513AC113AA SA-7XSD T 460 RGZESD Ball 1LE29513AD212AA SA-7XSD T 575 RGZESD Ball 1LE29513AD213AA SA-7XSD T 460 RGZESD Ball 1LE29512CA212AA SA-7XSD TS 460 RGZESD Ball 1LE29512DA212AA SA-7XSD TS 575 RGZESD Ball 1LE29512DA213AA SA-7XSD T 460 RGZESD Ball 1LE29512CB212AA SA-7XSD TS 460 RGZESD Ball 1LE29512DB212AA SA-7XSD T 575 RGZESD Ball 1LE29512CB213AA SA-7XSD T 460 RGZESD Ball 1LE29513AC212AA SA-7XSD T 575 RGZESD Ball 1LE29513AC213AA SA-7XSD T 460 RGZESD Ball 1LE29513CD112AA SA-7XSD T 575 RGZESD Ball 1LE29513CD113AA SA-7XSD T 460 RGZESD Ball 1LE29513AA112AA SA-7XSD TS 460 RGZESD Ball 1LE29513BA112AA SA-7XSD TS 575 RGZESD Ball 1LE29513BA113AA SA-7XSD T 460 RGZESD Ball 1LE29513AB112AA SA-7XSD TS 460 RGZESD Ball 1LE29513BB112AA SA-7XSD T 575 RGZESD Ball 1LE29513AB113AA SA-7XSD T 460 RGZESD Ball 1LE29513CC112AA SA-7XSD T 575 RGZESD Ball 1LE29513CC113AA SA-7XSD T 460 RGZESD Ball 1LE29513CD212AA SA-7XSD T 575 RGZESD Ball 1LE29513CD213AA SA-7XSD Stock Model Introduction General Purpose Duty Duty Purpose Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V All RGZESD motors will be discontinued when present stock is depleted DOE#CC032A Low Voltage AC Selection and Pricing Guide 3-11 Dimensions

68 Introduction General Purpose Duty Duty Purpose Dimensions - TEFC RGZESD HP RPM Frame Voltage Type DE Bearing Low Voltage AC Selection and Pricing Guide List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) T 460 RGZESD Ball 1LE29513AA212AA SA-7XSD TS 460 RGZESD Ball 1LE29513BA212AA SA-7XSD TS 575 RGZESD Ball 1LE29513BA213AA SA-7XSD T 460 RGZESD Ball 1LE29513AB212AA SA-7XSD TS 460 RGZESD Ball 1LE29513BB212AA SA-7XSD T 575 RGZESD Ball 1LE29513AB213AA SA-7XSD T 460 RGZESD Ball 1LE29513CC212AA SA-7XSD T 575 RGZESD Ball 1LE29513CC213AA SA-7XSD T 460 RGZESD Ball 1LE29514AD112AA SA-7XSD T 575 RGZESD Ball 1LE29514AD113AA SA-7XSD T 460 RGZESD Ball 1LE29513CA112AA SA-7XSD TS 460 RGZESD Ball 1LE29513DA112AA SA-7XSD TS 575 RGZESD Ball 1LE29513DA113AA SA-7XSD T 460 RGZESD Ball 1LE29513CB112AA SA-7XSD TS 460 RGZESD Ball 1LE29513DB112AA SA-7XSD T 575 RGZESD Ball 1LE29513CB113AA SA-7XSD T 460 RGZESD Ball 1LE29514AC112AA SA-7XSD T 575 RGZESD Ball 1LE29514AC113AA SA-7XSD T 460 RGZESD Ball 1LE29514AD212AA SA-7XSD T 575 RGZESD Ball 1LE29514AD213AA SA-7XSD T 460 RGZESD Roller 1LE29514CE112AA SA-7XSD T 460 RGZESD Ball 1LE29513CA212AA SA-7XSD TS 460 RGZESD Ball 1LE29513DA212AA SA-7XSD TS 575 RGZESD Ball 1LE29513DA213AA SA-7XSD T 460 RGZESD Ball 1LE29513CB212AA SA-7XSD TS 460 RGZESD Ball 1LE29513DB212AA SA-7XSD T 575 RGZESD Ball 1LE29513CB213AA SA-7XSD T 460 RGZESD Ball 1LE29514AC212AA SA-7XSD T 575 RGZESD Ball 1LE29514AC213AA SA-7XSD T 460 RGZESD Roller 1LE29514CD112AA SA-7XSD T 575 RGZESD Roller 1LE29514CD113AA SA-7XSD T 460 RGZESD Roller 1LE29514CE212AA SA-7XSD TS 460 RGZESD Ball 1LE29514BA212AA SA-7XSD TS 575 RGZESD Ball 1LE29514BA213AA SA-7XSD TS 460 RGZESD Ball 1LE29514BB212AA SA-7XSD T 460 RGZESD Ball 1LE29514AB212AA SA-7XSD T 575 RGZESD Ball 1LE29514AB213AA SA-7XSD B444T 460 RGZESD Ball 1LE29514EC112AA SA-7XSD TS 460 RGZESD Ball 1LE29514DC112AA SA-7XSD T 460 RGZESD Roller 1LE29514CC112AA SA-7XSD T 575 RGZESD Roller 1LE29514CC113AA SA-7XSD T 460 RGZESD Roller 1LE29514CD212AA SA-7XSD T 575 RGZESD Roller 1LE29514CD213AA SA-7XSD T 460 RGZESD Roller 1LE29514CE312AA SA-7XSD 2280 Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V All RGZESD motors will be discontinued when present stock is depleted Stock Model DOE#CC032A

69 - TEFC RGZESD HP RPM Frame Voltage Type DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TS 460 RGZESD Ball 1LE29514DA112AA SA-7XSD TS 575 RGZESD Ball 1LE29514DA113AA SA-7XSD TS 460 RGZESD Ball 1LE29514DB112AA SA-7XSD B444T 460 RGZESD Ball 1LE29514EB112AA SA-7XSD T 460 RGZESD Roller 1LE29514CB112AA SA-7XSD TS 575 RGZESD Ball 1LE29514DB113AA SA-7XSD T 575 RGZESD Roller 1LE29514CB113AA SA-7XSD B445T 460 RGZESD Ball 1LE29514EC212AA SA-7XSD TS 460 RGZESD Ball 1LE29514DC212AA SA-7XSD T 460 RGZESD Roller 1LE29514CC212AA SA-7XSD T 575 RGZESD Roller 1LE29514CC213AA SA-7XSD T 460 RGZESD Roller 1LE29514CD312AA SA-7XSD T 575 RGZESD Roller 1LE29514CD313AA SA-7XSD T 460 RGZESD Roller 1LE29514CE512AA SA-7XSD TS 460 RGZESD Ball 1LE29514DA212AA SA-7XSD TS 575 RGZESD Ball 1LE29514DA213AA SA-7XSD TS 460 RGZESD Ball 1LE29514DB212AA SA-7XSD B445T 460 RGZESD Ball 1LE29514EB212AA SA-7XSD T 460 RGZESD Roller 1LE29514CB212AA SA-7XSD TS 575 RGZESD Ball 1LE29514DB213AA SA-7XSD T 575 RGZESD Roller 1LE29514CB213AA SA-7XSD B447T 460 RGZESD Ball 1LE29514EC312AA SA-7XSD TS 460 RGZESD Ball 1LE29514DC312AA SA-7XSD T 460 RGZESD Roller 1LE29514CC312AA SA-7XSD T 575 RGZESD Roller 1LE29514CC313AA SA-7XSD T 460 RGZESD Roller 1LE29514CD412AA SA-7XSD T 575 RGZESD Roller 1LE29514CD413AA SA-7XSD T 460 RGZESD Roller 1LE29514CE612AA SA-7XSD TS 460 RGZESD Ball 1LE29514DA312AA SA-7XSD TS 575 RGZESD Ball 1LE29514DA313AA SA-7XSD B447T 460 RGZESD Ball 1LE29514EB312AA SA-7XSD TS 460 RGZESD Ball 1LE29514DB312AA SA-7XSD T 460 RGZESD Roller 1LE29514CB312AA SA-7XSD TS 575 RGZESD Ball 1LE29514DB313AA SA-7XSD T 575 RGZESD Roller 1LE29514CB313AA SA-7XSD B449T 460 RGZESD Ball 1LE29514EC512AA SA-7XSD TS 460 RGZESD Ball 1LE29514DC512AA SA-7XSD T 460 RGZESD Roller 1LE29514CC512AA SA-7XSD T 575 RGZESD Roller 1LE29514CC513AA SA-7XSD T 460 RGZESD Roller 1LE29514CD612AA SA-7XSD T 575 RGZESD Roller 1LE29514CD613AA SA-7XSD Stock Model Introduction General Purpose Duty Duty Purpose Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V All RGZESD motors will be discontinued when present stock is depleted DOE#CC032A Low Voltage AC Selection and Pricing Guide 3-13 Dimensions

70 - TEFC RGZESD HP RPM Frame Voltage Type DE Bearing List Price $ Mult. Sym. FL Amps High Efficiency FL Nom. Eff. (%) Weight (lbs) TS 460 RGZESD Ball 1LE29514DA512AA SA-7XSD TS 460 RGZESD Ball 1LE29514DB512AA SA-7XSD B449T 460 RGZESD Ball 1LE29514EB512AA SA-7XSD T 460 RGZESD Roller 1LE29514CB512AA SA-7XSD T 575 RGZESD Roller 1LE29514CB513AA SA-7XSD B449T 460 RGZESD Ball 1LE29514EC612AA SA-7XSD TS 460 RGZESD Ball 1LE29514DC612AA SA-7XSD T 460 RGZESD Roller 1LE29514CC612AA SA-7XSD T 575 RGZESD Roller 1LE29514CC613AA SA-7XSD S449LS 460 RGZESD Roller 1LE29514FD212AA SA-7XSD TS 460 RGZESD Ball 1LE29514DA612AA SA-7XSD TS 460 RGZESD Ball 1LE29514DB612AA SA-7XSD T 460 RGZESD Roller 1LE29514CB612AA SA-7XSD B449T 460 RGZESD Ball 1LE29514EB612AA SA-7XSD S449LS 460 RGZESD Roller 1LE29514FC112AA SA-7XSD S449SS 460 RGZESD Ball 1LE29514GA112AA SA-7XSD S449SS 460 RGZESD Ball 1LE29514GB212AA SA-7XSD S449LS 460 RGZESD Roller 1LE29514FB212AA SA-7XSD S449LS 460 RGZESD Roller 1LE29514FC312AA SA-7XSD S449SS 460 RGZESD Ball 1LE29514GA312AA SA-7XSD S449SS 460 RGZESD Ball 1LE29514GB312AA SA-7XSD S449LS 460 RGZESD Roller 1LE29514FB312AA SA-7XSD S449LS 460 RGZESD Roller 1LE29514FC412AA SA-7XSD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V All RGZESD motors will be discontinued when present stock is depleted Stock Model Dimensions Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide DOE#CC032A

71 - TEFC Multi-Speed SD10 MS - 1 Winding Variable Torque SD10 MS high efficiency, severe duty, multi-speed motors are ideal for both indoor and outdoor applications and in severe duty operating atmospheres, such as cooling towers, which require more than one base speed. They meet or exceed NEMA and CSA standards and the operational standards for severe operating environments. Specifications 1 to 250 HP 1.15 service factor, 40ºC ambient 1 winding, 1800/900 RPM, variable torque 3 phase, 60 Hz; 460 volt; 200, 230 & 575 volt available Meets or exceeds NEMA efficiency standards Class F insulation, Class B temperature rise NEMA design B, continuous duty 143T through 449T frame Features for Long Life Frame & Bearing Housings Cast iron construction for exceptional structural integrity and corrosion resistance. Condensation T-drains provided. Lifting eyebolts are included for frames > 75 lbs. Rotor A unique rotor bar design provides improved efficiency while larger bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel (C1045) shaft for maximum rotor performance. Specifications table begins on the next page Stator/Windings Manufactured with premium electrical grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross section reduces resistance and lowers stator losses. Insulation Proprietary NEMA Class F non-hygroscopic insulation system with Class B temperature rise, provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical shock. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves airflow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes Bearings Regreasable, oversized single shielded with cast iron inner caps. Alemite grease fittings on the inlets and pipe plugs on the relief ports for ease of routine maintenance. For added bearing protection, 143T-256T frames have a drive end shaft seal and 284T-449T frames have a drive end shaft V-ring slinger. Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. High Efficiency Oversized Conduit Box Cast iron construction that is larger than industry standards, diagonally-split, neoprene gasketed and rotatable in 90º increments for quick and easy connections. A ground lug is provided. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, zinc-plated hardware, epoxy enamel paint and stainless steel nameplate resist rust and corrosion. Modifiable & All Siemens motors are available with a wide variety of modifications and custom designs to meet your specific motor needs. Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 3-15 Dimensions

72 Introduction General Purpose Duty Duty Purpose Dimensions - TEFC Multi-Speed SD10 MS - 1 Winding Variable Torque HP Continuous High Low RPM Frame Voltage Type Low Voltage AC Selection and Pricing Guide DE Bearing High Efficiency List Price $ / T 460 SD10 MS Ball 1LE23011AM240AA3 521 SD / T 460 SD10 MS Ball 1LE23011AM340AA3 559 SD / T 460 SD10 MS Ball 1LE23011CM140AA3 641 SD / T 460 SD10 MS Ball 1LE23011CM340AA3 711 SD / T 460 SD10 MS Ball 1LE23011CM440AA3 800 SD / T 460 SD10 MS Ball 1LE23012AM140AA3 831 SD / T 460 SD10 MS Ball 1LE23012AM740AA SD / T 460 SD10 MS Ball 1LE23012AM240AA SD / T 460 SD10 MS Ball 1LE23012AM840AA SD / T 460 SD10 MS Ball 1LE23012BM140AA SD / T 460 SD10 MS Ball 1LE23012BM740AA SD / T 460 SD10 MS Ball 1LE23012BM240AA SD / T 460 SD10 MS Ball 1LE23012BM840AA SD / T 460 SD10 MS Ball 1LE23012CM140AA SD / T 575 SD10 MS Ball 1LE23012CM144AA SD / T 460 SD10 MS Ball 1LE23012CM740AA SD / T 575 SD10 MS Ball 1LE23012CM744AA SD / T 460 SD10 MS Ball 1LE23012CM240AA SD / T 575 SD10 MS Ball 1LE23012CM244AA SD / T 460 SD10 MS Ball 1LE23012CM840AA SD / T 575 SD10 MS Ball 1LE23012CM844AA SD / T 460 SD10 MS Ball 1LE23013AM140AA SD / T 575 SD10 MS Ball 1LE23013AM144AA SD / T 460 SD10 MS Ball 1LE23013AM240AA SD / T 575 SD10 MS Ball 1LE23013AM244AA SD / T 460 SD10 MS Ball 1LE23013CM140AA SD / T 575 SD10 MS Ball 1LE23013CM144AA SD / T 460 SD10 MS Ball 1LE23013CM240AA SD / T 575 SD10 MS Ball 1LE23013CM244AA SD / T 460 SD10 MS Ball 1LE23014AM240AA SD / T 575 SD10 MS Ball 1LE23014AM244AA SD / TS 460 SD10 MS Ball 1LE23014DM140AA SD / TS 575 SD10 MS Ball 1LE23014DM144AA SD /900 B444T 460 SD10 MS Ball 1LE23014EM140AA SD /900 B444T 575 SD10 MS Ball 1LE23014EM144AA SD / TS 460 SD10 MS Ball 1LE23014DM240AA SD / TS 575 SD10 MS Ball 1LE23014DM244AA SD /900 B445T 460 SD10 MS Ball 1LE23014EM240AA SD /900 B445T 575 SD10 MS Ball 1LE23014EM244AA SD / TS 460 SD10 MS Ball 1LE23014DM340AA SD / TS 575 SD10 MS Ball 1LE23014DM544AA SD /900 B447T 460 SD10 MS Ball 1LE23014EM540AA SD /900 B447T 575 SD10 MS Ball 1LE23014EM544AA SD4 Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only FL Amps at 460V or 575V Available in RGZZESD designs. Contact factory for pricing. Multi. Sym. Stock Model

73 - TEFC Multi-Speed SD10 MS - 1 Winding Variable Torque HP Continuous High Low RPM Frame Voltage Type DE Bearing High Efficiency List Price $ / TS 460 SD10 MS Ball 1LE23014EM540AA SD / TS 575 SD10 MS Ball 1LE23014DM544AA SD /900 B449T 460 SD10 MS Ball 1LE23014EM540AA SD /900 B449T 575 SD10 MS Ball 1LE23014EM544AA SD / TS 460 SD10 MS Ball 1LE23014DM640AA SD / TS 575 SD10 MS Ball 1LE23014DM644AA SD /900 B449T 460 SD10 MS Ball 1LE23014EM640AA SD /900 B449T 575 SD10 MS Ball 1LE23014EM644AA SD4 Multi. Sym. Stock Model Introduction General Purpose Duty Lines Speeds L1 L2 L3 Conn. Low Speed T1 T2 T3 T4 T5 T6 Open Y High Speed T6 T4 T5 T1 T2 T3 Together YY Duty Purpose Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only FL Amps at 460V or 575V Available in RGZZESD designs. Contact factory for pricing Low Voltage AC Selection and Pricing Guide 3-17 Dimensions

74 Introduction General Purpose Duty Duty - TEFC severe duty TEFC motors are available in two configurations they exceed NEMA Premium efficiency with our exclusive, leading-edge, die cast copper rotor design (143T 256T) or meet NEMA Premium efficiency with our die cast aluminum rotor design. Either way, these motors significantly reduce operating costs and pay for themselves in a short time through energy savings. They are ideal for use in chemical processing, mining, foundry, pulp and paper, waste management and petro/ chemical applications. Specifications 1 to 400 HP 1.15 service factor, 40ºC ambient 3600, 1800 or 1200 RPM 3-phase, 60 Hz; /460 and 575 volt operation (143T -256T) 3-phase, 60 Hz; 230/460 volt operation under 25 HP, 460 volt 25 HP and above, 200 & 575 volt available (284T S449T) Meets or exceeds NEMA Premium efficiency standards Class F insulation, Class B temperature 1.0SF NEMA design B (except as noted), continuous duty Meets IP54 & IEEE T to S449T frame Features for Long Life Frame & Bearing Housings Cast iron construction for exceptional structural integrity & corrosion resistance, equipped with integrally cast feet. Condensation T-drains are provided. Lifting eyebolts are included with motors > 75 lbs. Rotor Each rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel (C1045) shaft for maximum rotor performance. Specifications table begins on the next page Stator/Windings Manufactured with premium electrical-grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross-section reduces resistance and lowers stator losses. Insulation Proprietary inverterrated Class F non-hygroscopic insulation system with NEMA Class B temperature 1.0SF provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical shock. This insulation system meets or exceeds NEMA MG1-2006, Part 31 making all motors suitable for operation with Adjustable frequency drives. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves air flow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes. Bearings Regreasable, oversized double shielded (143T 256T) / single shielded (284T S449T) with cast iron inner caps on both ends of the motor. Alemite grease fittings on the inlets and pipe plugs on the relief ports for ease of routine maintenance. All motors are equipped with drive end and opposite drive end shaft V-ring slingers for added bearing protection. Provisions for Inpro/ Seal bearing isolators are standard on both ends. Lubrication A specially formulated, high temperature tested, polyurea based grease is used to provide more than four times the lubrication life of other greases. Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 NEMA Premium Efficiency Oversized Conduit Box Cast iron construction that is larger than industry standards, diagonally-split, neoprene gasketed and rotatable in 90º increments for quick and easy connections. A ground lug is provided. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, polycarbonate fan, zinc-plated hardware, epoxy enamel paint and stainless steel nameplate resist rust and corrosion. Modifiable & Siemens motors are available with a wide variety of modifications and custom designs to meet your specific motor needs. Dimensions Purpose Low Voltage AC Selection and Pricing Guide

75 - TEFC (Aluminum Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) T /460 Ball 1LE23211AA114AA3 408 SD T 575 Ball 1LE23211AA113AA3 408 SD T /460 Ball 1LE23211AB214AA3 381 SD T 575 Ball 1LE23211AB213AA3 381 SD T /460 Ball 1LE23211AC314AA3 473 SD T 575 Ball 1LE23211AC313AA3 473 SD T /460 Ball 1LE23211AA214AA3 408 SD T 575 Ball 1LE23211AA213AA3 408 SD T /460 Ball 1LE23211AB314AA3 422 SD T 575 Ball 1LE23211AB313AA3 422 SD T /460 Ball 1LE23211CC114AA3 533 SD T 575 Ball 1LE23211CC113AA3 533 SD T /460 Ball 1LE23211AA314AA3 488 SD T 575 Ball 1LE23211AA313AA3 488 SD T /460 Ball 1LE23211AB414AA3 465 SD T 575 Ball 1LE23211AB413AA3 465 SD T /460 Ball 1LE23211CC314AA3 596 SD T 575 Ball 1LE23211CC313AA3 596 SD T /460 Ball 1LE23211CA114AA3 549 SD T 575 Ball 1LE23211CA113AA3 549 SD T /460 Ball 1LE23211CB114AA3 515 SD T 575 Ball 1LE23211CB113AA3 515 SD T /460 Ball 1LE23212AC114AA3 726 SD T 575 Ball 1LE23212AC113AA3 726 SD T /460 Ball 1LE23211CA314AA3 680 SD T 575 Ball 1LE23211CA313AA3 680 SD T /460 Ball 1LE23211CB314AA3 602 SD T 575 Ball 1LE23211CB313AA3 602 SD T /460 Ball 1LE23212AC214AA SD T 575 Ball 1LE23212AC213AA SD T /460 Ball 1LE23212AA114AA3 821 SD T 575 Ball 1LE23212AA113AA3 821 SD T /460 Ball 1LE23212AB114AA3 816 SD T 575 Ball 1LE23212AB113AA3 816 SD T /460 Ball 1LE23212BC114AA SD T 575 Ball 1LE23212BC113AA SD T /460 Ball 1LE23212AA214AA3 960 SD T 575 Ball 1LE23212AA213AA3 960 SD T /460 Ball 1LE23212AB214AA3 984 SD T 575 Ball 1LE23212AB213AA3 984 SD T /460 Ball 1LE23212BC214AA SD T 575 Ball 1LE23212BC213AA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V DOE#CC032A Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Frames available after RGZEESD stock motors are depleted 1 CW Rotation facing opposite drive end 2 NEMA Design A Low Voltage AC Selection and Pricing Guide Stock Model 3-19 Introduction General Purpose Duty Duty Purpose Dimensions

76 Introduction General Purpose Duty Duty Purpose Dimensions - TEFC (Aluminum Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 FL Amps* FL Nom. Eff. (%) Weight (lbs) T /460 Ball 1LE23212BA114AA SD T 575 Ball 1LE23212BA113AA SD T /460 Ball 1LE23212BB114AA SD T 575 Ball 1LE23212BB113AA SD T 230/460 Ball 1LE23212CC116AA SD T 575 Ball 1LE23212CC113AA SD T /460 Ball 1LE23212BA214AA SD T 575 Ball 1LE23212BA213AA SD T /460 Ball 1LE23212BB214AA SD T 575 Ball 1LE23212BB213AA SD T 230/460 Ball 1LE23212CC216AA SD T 575 Ball 1LE23212CC213AA SD TS 460 Ball 1LE23212DA112AA SD TS 575 Ball 1LE23212DA113AA SD TS 460 Ball 1LE23212DB112AA SD T 460 Ball 1LE23212CB112AA SD TS 575 Ball 1LE23212DB113AA SD T 575 Ball 1LE23212CB113AA SD T 460 Ball 1LE23213AC112AA SD T 575 Ball 1LE23213AC113AA SD TS 460 Ball 1LE23212DA212AA SD TS 575 Ball 1LE23212DA213AA SD TS 460 Ball 1LE23212DB212AA SD T 460 Ball 1LE23212CB212AA SD TS 575 Ball 1LE23212DB213AA SD T 575 Ball 1LE23212CB213AA SD T 460 Ball 1LE23213AC212AA SD T 575 Ball 1LE23213AC213AA SD TS 460 Ball 1LE23213BA112AA SD TS 575 Ball 1LE23213BA113AA SD TS 460 Ball 1LE23213BB112AA SD T 460 Ball 1LE23213AB112AA SD TS 575 Ball 1LE23213BB113AA SD T 575 Ball 1LE23213AB113AA SD T 460 Ball 1LE23213CC112AA SD T 575 Ball 1LE23213CC113AA SD TS 460 Ball 1LE23213BA212AA SD TS 575 Ball 1LE23213BA213AA SD TS 460 Ball 1LE23213BB212AA SD T 460 Ball 1LE23213AB212AA SD TS 575 Ball 1LE23213BB213AA SD T 575 Ball 1LE23213AB213AA SD T 460 Ball 1LE23213CC212AA SD T 575 Ball 1LE23213CC213AA SD Stock Model Low Voltage AC Selection and Pricing Guide DOE#CC032A

77 - TEFC (Aluminum Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DOE#CC032A DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) TS 460 Ball 1LE23213DA112AA SD TS 575 Ball 1LE23213DA113AA SD TS 460 Ball 1LE23213DB112AA SD T 460 Ball 1LE23213CB112AA SD TS 575 Ball 1LE23213DB113AA SD T 575 Ball 1LE23213CB113AA SD T 460 Ball 1LE23214AC112AA SD T 575 Ball 1LE23214AC113AA SD TS 460 Ball 1LE23213DA212AA SD TS 575 Ball 1LE23213DA213AA SD TS 460 Ball 1LE23213DB212AA SD T 460 Ball 1LE23213CB212AA SD TS 575 Ball 1LE23213DB213AA SD T 575 Ball 1LE23213CB213AA SD T 460 Ball 1LE23214AC212AA SD T 575 Ball 1LE23214AC213AA SD TS 460 Ball 1LE23214BA212AA SD TS 575 Ball 1LE23214BA213AA SD TS 460 Ball 1LE23214BB212AA SD T 460 Ball 1LE23214AB212AA SD TS 575 Ball 1LE23214BB213AA SD T 575 Ball 1LE23214AB213AA SD TS 460 Ball 1LE23214DC112AA SD T 460 Roller 1LE23214CC112AA SD B444T 460 Ball 1LE23214EC112AA SD TS 575 Ball 1LE23214DC113AA SD T 575 Roller 1LE23214CC113AA SD B444T 575 Ball 1LE23214EC113AA SD TS 460 Ball 1LE23214DA112AA SD TS 575 Ball 1LE23214DA113AA SD TS 460 Ball 1LE23214DB112AA SD T 460 Roller 1LE23214CB112AA SD B444T 460 Ball 1LE23214EB112AA SD TS 575 Ball 1LE23214DB113AA SD T 575 Roller 1LE23214CB113AA SD B444T 575 Ball 1LE23214EB113AA SD TS 460 Ball 1LE23214DC212AA SD T 460 Roller 1LE23214CC212AA SD B445T 460 Ball 1LE23214EC212AA SD TS 575 Ball 1LE23214DC213AA SD T 575 Roller 1LE23214CC213AA SD B445T 575 Ball 1LE23214EC213AA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Frames available after RGZEESD stock motors are depleted 1 CW Rotation facing opposite drive end 2 NEMA Design A Low Voltage AC Selection and Pricing Guide Stock Model 3-21 Introduction General Purpose Duty Duty Purpose Dimensions

78 Introduction General Purpose Duty Duty Purpose Dimensions - TEFC (Aluminum Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) TS 460 Ball 1LE23214DA212AA SD TS 575 Ball 1LE23214DA213AA SD TS 460 Ball 1LE23214DB212AA SD T 460 Roller 1LE23214CB212AA SD B445T 460 Ball 1LE23214EB212AA SD TS 575 Ball 1LE23214DB213AA SD T 575 Roller 1LE23214CB213AA SD B445T 575 Ball 1LE23214EB213AA SD TS 460 Ball 1LE23214DC312AA SD T 460 Roller 1LE23214CC312AA SD B447T 460 Ball 1LE23214EC312AA SD TS 575 Ball 1LE23214DC313AA SD T 575 Roller 1LE23214CC313AA SD B447T 575 Ball 1LE23214EC313AA SD TS 460 Ball 1LE23214DA312AA SD TS 575 Ball 1LE23214DA313AA SD TS 460 Ball 1LE23214DB312AA SD T 460 Roller 1LE23214CB312AA SD B447T 460 Ball 1LE23214EB312AA SD TS 575 Ball 1LE23214DB313AA SD T 575 Roller 1LE23214CB313AA SD B447T 575 Ball 1LE23214EB313AA SD TS 460 Ball 1LE23214DC512AA SD T 460 Roller 1LE23214CC512AA SD B449T 460 Ball 1LE23214EC512AA SD TS 575 Ball 1LE23214DC513AA SD T 575 Roller 1LE23214CC513AA SD B449T 575 Ball 1LE23214EC513AA SD TS 460 Ball 1LE23214DA512AA SD TS 575 Ball 1LE23214DA513AA SD TS 460 Ball 2 1LE23214DB512AA SD T 460 Roller 2 1LE23214CB512AA SD B449T 460 Ball 2 1LE23214EB512AA SD TS 575 Ball 2 1LE23214DB513AA SD T 575 Roller 2 1LE23214CB513AA SD B449T 575 Ball 2 1LE23214EB513AA SD TS 460 Ball 2 1LE23214DC612AA SD T 460 Roller 2 1LE23214CC612AA SD B449T 460 Ball 2 1LE23214EC612AA SD TS 575 Ball 2 1LE23214DC613AA SD T 575 Roller 2 1LE23214CC613AA SD B449T 575 Ball 2 1LE23214EC613AA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Frames available after RGZEESD stock motors are depleted 1 CW Rotation facing opposite drive end 2 NEMA Design A Stock Model Low Voltage AC Selection and Pricing Guide DOE#CC032A

79 - TEFC (Aluminum Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DOE#CC032A DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) TS 460 Ball 1LE23214DA612AA SD TS 575 Ball 1LE23214DA613AA SD TS 460 Ball 2 1LE23214DB612AA SD T 460 Roller 2 1LE23214CB612AA SD B449T 460 Ball 2 1LE23214EB612AA SD TS 575 Ball 2 1LE23214DB613AA SD T 575 Roller 2 1LE23214CB613AA SD B449T 575 Ball 2 1LE23214EB613AA SD S449LS 460 Roller 2 1LE23214FC112AA SD S449LS 575 Roller 2 1LE23214FC113AA SD S449SS 460 Ball 1 1LE23214GA112AA SD S449SS 575 Ball 1 1LE23214GA113AA SD S449SS 460 Ball 1LE23214GB212AA SD S449LS 460 Roller 1LE23214FB212AA SD S449SS 575 Ball 1LE23214GB213AA SD S449LS 575 Roller 1LE23214FB213AA SD S449SS 460 Ball 1 1LE23214GA312AA SD S449SS 575 Ball 1 1LE23214GA313AA SD S449SS 460 Ball 1LE23214GB312AA SD S449LS 460 Roller 1LE23214FB312AA SD S449SS 575 Ball 1LE23214GB313AA SD S449LS 575 Roller 1LE23214FB313AA SD C-Face, Horizontal, Footless TC /460 Ball 1LE23211AA114GA3 471 SD TC 575 Ball 1LE23211AA113GA3 471 SD TC /460 Ball 1LE23211AB214GA3 445 SD TC 575 Ball 1LE23211AB213GA3 445 SD TC /460 Ball 1LE23211AC314GA3 536 SD TC 575 Ball 1LE23211AC313GA3 536 SD TC /460 Ball 1LE23211AA214GA3 471 SD TC 575 Ball 1LE23211AA213GA3 471 SD TC /460 Ball 1LE23211AB314GA3 486 SD TC 575 Ball 1LE23211AB313GA3 486 SD TC /460 Ball 1LE23211CC114GA3 626 SD TC 575 Ball 1LE23211CC113GA3 626 SD TC /460 Ball 1LE23211AA314GA3 551 SD TC 575 Ball 1LE23211AA313GA3 551 SD TC /460 Ball 1LE23211AB414GA3 528 SD TC 575 Ball 1LE23211AB413GA3 528 SD TC /460 Ball 1LE23211CC314GA3 689 SD TC 575 Ball 1LE23211CC313GA3 689 SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Frames available after RGZEESD stock motors are depleted 1 CW Rotation facing opposite drive end 2 NEMA Design A Low Voltage AC Selection and Pricing Guide Stock Model 3-23 Introduction General Purpose Duty Duty Purpose Dimensions

80 - TEFC Introduction (Aluminum Rotor) HP RPM Frame Voltage Type C-Face, Horizontal, Footless - continued DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) TC /460 Ball 1LE23211CA114GA3 643 SD TC 575 Ball 1LE23211CA113GA3 643 SD TC /460 Ball 1LE23211CB114GA3 608 SD TC 575 Ball 1LE23211CB113GA3 608 SD TC /460 Ball 1LE23212AC114GA3 820 SD TC 575 Ball 1LE23212AC113GA3 820 SD TC /460 Ball 1LE23211CA314GA3 773 SD TC 575 Ball 1LE23211CA313GA3 773 SD TC /460 Ball 1LE23211CB314GA3 696 SD TC 575 Ball 1LE23211CB313GA3 696 SD TC /460 Ball 1LE23212AC214GA SD TC 575 Ball 1LE23212AC213GA SD TC /460 Ball 1LE23212AA114GA3 914 SD TC 575 Ball 1LE23212AA113GA3 914 SD TC /460 Ball 1LE23212AB114GA3 910 SD TC 575 Ball 1LE23212AB113GA3 910 SD TC /460 Ball 1LE23212BC114GA SD TC 575 Ball 1LE23212BC113GA SD TC /460 Ball 1LE23212AA214GA SD TC 575 Ball 1LE23212AA213GA SD TC /460 Ball 1LE23212AB214GA SD TC 575 Ball 1LE23212AB213GA SD TC /460 Ball 1LE23212BC214GA SD TC 575 Ball 1LE23212BC213GA SD TC /460 Ball 1LE23212BA114GA SD TC 575 Ball 1LE23212BA113GA SD TC /460 Ball 1LE23212BB114GA SD TC 575 Ball 1LE23212BB113GA SD TC /460 Ball 1LE23212BA214GA SD TC 575 Ball 1LE23212BA213GA SD TC /460 Ball 1LE23212BB214GA SD TC 575 Ball 1LE23212BB213GA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Frames available after RGZEESD stock motors are depleted 1 CW Rotation facing opposite drive end 2 NEMA Design A Stock Model Dimensions General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide DOE#CC032A

81 - TEFC (Copper Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted DE Bearing List Price $ NEMA Premium Efficiency Plus Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) T /460 Ball 1LE23111AB214AA3 444 SD T 575 Ball 1LE23111AB213AA3 444 SD T /460 Ball 1LE23111AC314AA3 551 SD T 575 Ball 1LE23111AC313AA3 551 SD T /460 Ball 1LE23111AA214AA3 476 SD T 575 Ball 1LE23111AA213AA3 476 SD T /460 Ball 1LE23111AB314AA3 492 SD T 575 Ball 1LE23111AB313AA3 492 SD T /460 Ball 1LE23111AA314AA3 569 SD T 575 Ball 1LE23111AA313AA3 569 SD T /460 Ball 1LE23111AB414AA3 543 SD T 575 Ball 1LE23111AB413AA3 543 SD T /460 Ball 1LE23111CA114AA3 641 SD T 575 Ball 1LE23111CA113AA3 641 SD T /460 Ball 1LE23111CB114AA3 601 SD T 575 Ball 1LE23111CB113AA3 601 SD T /460 Ball 1LE23112AC114AA3 847 SD T 575 Ball 1LE23112AC113AA3 847 SD T /460 Ball 1LE23111CA314AA3 793 SD T 575 Ball 1LE23111CA313AA3 793 SD T /460 Ball 1LE23111CB314AA3 702 SD T 575 Ball 1LE23111CB313AA3 702 SD T /460 Ball 1LE23112AC214AA SD T 575 Ball 1LE23112AC213AA SD T /460 Ball 1LE23112AA114AA3 958 SD T 575 Ball 1LE23112AA113AA3 958 SD T /460 Ball 1LE23112AB114AA3 952 SD T 575 Ball 1LE23112AB113AA3 952 SD T /460 Ball 1LE23112BC114AA SD T 575 Ball 1LE23112BC113AA SD T /460 Ball 1LE23112AA214AA SD T 575 Ball 1LE23112AA213AA SD T /460 Ball 1LE23112AB214AA SD T 575 Ball 1LE23112AB213AA SD T /460 Ball 1LE23112BC214AA SD T 575 Ball 1LE23112BC213AA SD T /460 Ball 1LE23112BA114AA SD T 575 Ball 1LE23112BA113AA SD T /460 Ball 1LE23112BB114AA SD T 575 Ball 1LE23112BB113AA SD T /460 Ball 1LE23112BA214AA SD T 575 Ball 1LE23112BA213AA SD T /460 Ball 1LE23112BB214AA SD T 575 Ball 1LE23112BB213AA SD Prices and specifications are subject to change without notice Stock availability subject to sale DOE#CC032A Exceeds Energy Independence & Security Act Efficiency Levels Low Voltage AC Selection and Pricing Guide Stock Model delivery for stocked motors only *FL Amps at 460V or 575V 3-25 Introduction General Purpose Duty Duty Purpose Dimensions

82 Introduction General Purpose Duty Duty Purpose Dimensions - TEFC (Copper Rotor) HP RPM Frame Voltage Type C-Face, Horizontal, Footless DE Bearing List Price $ NEMA Premium Efficiency Plus Mult. Sym. Exceeds Energy Independence & Security Act Efficiency Levels 2010 FL Amps* FL Nom. Eff. (%) Weight (lbs) TC /460 Ball 1LE23111AB214GA3 519 SD TC 575 Ball 1LE23111AB213GA3 519 SD TC /460 Ball 1LE23111AC314GA3 625 SD TC 575 Ball 1LE23111AC313GA3 625 SD TC /460 Ball 1LE23111AA214GA3 549 SD TC 575 Ball 1LE23111AA213GA3 549 SD TC /460 Ball 1LE23111AB314GA3 567 SD TC 575 Ball 1LE23111AB313GA3 567 SD TC /460 Ball 1LE23111AA314GA3 643 SD TC 575 Ball 1LE23111AA313GA3 643 SD TC /460 Ball 1LE23111AB414GA3 616 SD TC 575 Ball 1LE23111AB413GA3 616 SD TC /460 Ball 1LE23111CA114GA3 750 SD TC 575 Ball 1LE23111CA113GA3 750 SD TC /460 Ball 1LE23111CB114GA3 710 SD TC 575 Ball 1LE23111CB113GA3 710 SD TC /460 Ball 1LE23112AC114GA3 957 SD TC 575 Ball 1LE23112AC113GA3 957 SD TC /460 Ball 1LE23111CA314GA3 902 SD TC 575 Ball 1LE23111CA313GA3 902 SD TC /460 Ball 1LE23111CB314GA3 812 SD TC 575 Ball 1LE23111CB313GA3 812 SD TC /460 Ball 1LE23112AC214GA SD TC 575 Ball 1LE23112AC213GA SD TC /460 Ball 1LE23112AA114GA SD TC 575 Ball 1LE23112AA113GA SD TC /460 Ball 1LE23112AB114GA SD TC 575 Ball 1LE23112AB113GA SD TC /460 Ball 1LE23112BC114GA SD TC 575 Ball 1LE23112BC113GA SD TC /460 Ball 1LE23112AA214GA SD TC 575 Ball 1LE23112AA213GA SD TC /460 Ball 1LE23112AB214GA SD TC 575 Ball 1LE23112AB213GA SD TC /460 Ball 1LE23112BC214GA SD TC 575 Ball 1LE23112BC213GA SD TC /460 Ball 1LE23112BA114GA SD TC 575 Ball 1LE23112BA113GA SD TC /460 Ball 1LE23112BB114GA SD TC 575 Ball 1LE23112BB113GA SD TC /460 Ball 1LE23112BA214GA SD TC 575 Ball 1LE23112BA213GA SD TC /460 Ball 1LE23112BB214GA SD TC 575 Ball 1LE23112BB213GA SD Stock Model Prices and specifications are subject to change without notice Stock availability subject to sale Low Voltage AC Selection and Pricing Guide delivery for stocked motors only *FL Amps at 460V or 575V DOE#CC032A

83 - TEFC RGZEESD RGZEESD severe duty TEFC motors meet or exceed NEMA Premium efficiencies. These motors significantly reduce operating costs and pay for themselves in a short time through energy savings. They are ideal for use in chemical processing, mining, foundry, pulp and paper, waste management and petro/ chemical applications. Specifications 25 to 400 HP 1.15 service factor, 40ºC ambient 3600, 1800 or 1200 RPM 3-phase, 60 Hz; 230/460 volt operation under 25 HP, 460 volt 25 HP and above, 200 & 575 volt available Meets or exceeds NEMA Premium efficiency standards Class F insulation, Class B temperature 1.0SF NEMA design B (except as noted), continuous duty Meets IP55 & IEEE T to S449 frame RGZEESD Features for Long Life Frame & Bearing Housings Cast iron construction for exceptional structural integrity & corrosion resistance, equipped with integrally cast feet. Condensation T-drains are provided. Lifting eyebolts are included with motors > 75 lbs. Rotor Each rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel (C1045) shaft for maximum rotor performance. Stator/Windings Manufactured with premium electrical-grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross-section reduces resistance and lowers stator losses. Insulation Proprietary inverterrated Class F non-hygroscopic insulation system with NEMA Class B temperature 1.0SF provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical shock. This insulation system meets or exceeds NEMA MG1-2006, Part 31 making all motors suitable for operation with adjustable frequency drives. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves air flow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes. Bearings Regreasable, oversized single shielded, with cast iron inner caps. Alemite grease fittings on the inlets and pipe plugs on the relief ports for ease of routine maintenance. All motors are equipped with drive end and opposite drive end shaft V-ring slingers for added bearing protection. Provisions for Inpro/Seal bearing isolators are standard on both ends. Lubrication A specially formulated, high temperature tested, polyurea based grease is used to provide more than four times the lubrication life of other greases. Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 NEMA Premium Efficiency Oversized Conduit Box Cast iron construction that is larger than industry standards, diagonally-split, neoprene gasketed and rotatable in 90º increments for quick and easy connections. Includes a ground lug. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, polycarbonate fan, zinc-plated hardware, epoxy enamel paint and stainless steel nameplate resist rust and corrosion. Modifiable & Cutom Siemens motors are available with a wide variety of modifications and custom designs to meet your specific motor needs. Introduction General Purpose Duty Duty Purpose Specifications table begins on the next page Low Voltage AC Selection and Pricing Guide 3-27 Dimensions

84 Introduction General Purpose Duty Duty Purpose Dimensions - TEFC RGZEESD HP RPM Frame Voltage Type DE Bearing List Price $ Mult. Sym. NEMA Premium Efficiency FL Amps* FL Nom. Eff. (%) Weight (lbs) T 230/460 RGZEESD Ball 1LE29721AA116AA3 410 SA-7EXSD T 575 RGZEESD Ball 1LE29721AA113AA3 410 SA-7EXSD T 230/460 RGZEESD Ball 1LE29721AB216AA3 384 SA-7EXSD T 575 RGZEESD Ball 1LE29721AB213AA3 384 SA-7EXSD T 230/460 RGZEESD Ball 1LE29721AA216AA3 410 SA-7EXSD T 575 RGZEESD Ball 1LE29721AA213AA3 410 SA-7EXSD T 230/460 RGZEESD Ball 1LE29721AB316AA3 426 SA-7EXSD T 575 RGZEESD Ball 1LE29721AB313AA3 426 SA-7EXSD T 230/460 RGZEESD Ball 1LE29721AA316AA3 491 SA-7EXSD T 575 RGZEESD Ball 1LE29721AA313AA3 491 SA-7EXSD T 230/460 RGZEESD Ball 1LE29721AB416AA3 469 SA-7EXSD T 575 RGZEESD Ball 1LE29721AB413AA3 469 SA-7EXSD T 230/460 RGZEESD Ball 1LE29721CA116AA3 553 SA-7EXSD T 575 RGZEESD Ball 1LE29721CA113AA3 553 SA-7EXSD T 230/460 RGZEESD Ball 1LE29721CB116AA3 519 SA-7EXSD T 575 RGZEESD Ball 1LE29721CB113AA3 519 SA-7EXSD T 230/460 RGZEESD Ball 1LE29721CA316AA3 685 SA-7EXSD T 575 RGZEESD Ball 1LE29721CA313AA3 685 SA-7EXSD T 230/460 RGZEESD Ball 1LE29721CB316AA3 607 SA-7EXSD T 575 RGZEESD Ball 1LE29721CB313AA3 607 SA-7EXSD T 230/460 RGZEESD Ball 1LE29722AA116AA3 828 SA-7EXSD T 575 RGZEESD Ball 1LE29722AA113AA3 828 SA-7EXSD T 230/460 RGZEESD Ball 1LE29722AB116AA3 823 SA-7EXSD T 575 RGZEESD Ball 1LE29722AB113AA3 823 SA-7EXSD T 230/460 RGZEESD Ball 1LE29722AA216AA3 968 SA-7EXSD T 575 RGZEESD Ball 1LE29722AA213AA3 968 SA-7EXSD T 230/460 RGZEESD Ball 1LE29722AB216AA3 991 SA-7EXSD T 575 RGZEESD Ball 1LE29722AB213AA3 991 SA-7EXSD T 230/460 RGZEESD Ball 1LE29722BA116AA SA-7EXSD T 575 RGZEESD Ball 1LE29722BA113AA SA-7EXSD T 230/460 RGZEESD Ball 1LE29722BB116AA SA-7EXSD T 575 RGZEESD Ball 1LE29722BB113AA SA-7EXSD T 230/460 RGZEESD Ball 1LE29722CC116AA SA-7EXSD T 575 RGZEESD Ball 1LE29722CC113AA SA-7EXSD T 230/460 RGZEESD Ball 1LE29722BA216AA SA-7EXSD T 575 RGZEESD Ball 1LE29722BA213AA SA-7EXSD T 230/460 RGZEESD Ball 1LE29722BB216AA SA-7EXSD T 575 RGZEESD Ball 1LE29722BB213AA SA-7EXSD T 230/460 RGZEESD Ball 1LE29722CC216AA SA-7EXSD T 575 RGZEESD Ball 1LE29722CC213AA SA-7EXSD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V All RGZEESD motors will be discontinued when present stock is depleted Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Stock Model Low Voltage AC Selection and Pricing Guide DOE#CC032A

85 - TEFC RGZEESD HP RPM Frame Voltage Type DE Bearing List Price $ Mult. Sym. Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 NEMA Premium Efficiency FL Amps* FL Nom. Eff. (%) Weight (lbs) TS 460 RGZEESD Ball 1LE29722DA112AA SA-7EXSD TS 575 RGZEESD Ball 1LE29722DA113AA SA-7EXSD TS 460 RGZEESD Ball 1LE29722DB112AA SA-7EXSD T 460 RGZEESD Ball 1LE29722CB112AA SA-7EXSD TS 575 RGZEESD Ball 1LE29722DB113AA SA-7EXSD T 575 RGZEESD Ball 1LE29722CB113AA SA-7EXSD T 460 RGZEESD Ball 1LE29723AC112AA SA-7EXSD T 575 RGZEESD Ball 1LE29723AC113AA SA-7EXSD TS 460 RGZEESD Ball 1LE29722DA212AA SA-7EXSD TS 575 RGZEESD Ball 1LE29722DA213AA SA-7EXSD TS 460 RGZEESD Ball 1LE29722DB212AA SA-7EXSD T 460 RGZEESD Ball 1LE29722CB212AA SA-7EXSD TS 575 RGZEESD Ball 1LE29722DB213AA SA-7EXSD T 575 RGZEESD Ball 1LE29722CB213AA SA-7EXSD T 460 RGZEESD Ball 1LE29723AC212AA SA-7EXSD T 575 RGZEESD Ball 1LE29723AC213AA SA-7EXSD TS 460 RGZEESD Ball 1LE29723BA112AA SA-7EXSD TS 575 RGZEESD Ball 1LE29723BA113AA SA-7EXSD TS 460 RGZEESD Ball 1LE29723BB112AA SA-7EXSD T 460 RGZEESD Ball 1LE29723AB112AA SA-7EXSD TS 575 RGZEESD Ball 1LE29723BB113AA SA-7EXSD T 575 RGZEESD Ball 1LE29723AB113AA SA-7EXSD T 460 RGZEESD Ball 1LE29723CC112AA SA-7EXSD T 575 RGZEESD Ball 1LE29723CC113AA SA-7EXSD TS 460 RGZEESD Ball 1LE29723BA212AA SA-7EXSD TS 575 RGZEESD Ball 1LE29723BA213AA SA-7EXSD TS 460 RGZEESD Ball 1LE29723BB212AA SA-7EXSD T 460 RGZEESD Ball 1LE29723AB212AA SA-7EXSD TS 575 RGZEESD Ball 1LE29723BB213AA SA-7EXSD T 575 RGZEESD Ball 1LE29723AB213AA SA-7EXSD T 460 RGZEESD Ball 1LE29723CC212AA SA-7EXSD T 575 RGZEESD Ball 1LE29723CC213AA SA-7EXSD TS 460 RGZEESD Ball 1LE29723DA112AA SA-7EXSD TS 575 RGZEESD Ball 1LE29723DA113AA SA-7EXSD TS 460 RGZEESD Ball 1LE29723DB112AA SA-7EXSD T 460 RGZEESD Ball 1LE29723CB112AA SA-7EXSD TS 575 RGZEESD Ball 1LE29723DB113AA SA-7EXSD T 575 RGZEESD Ball 1LE29723CB113AA SA-7EXSD T 460 RGZEESD Ball 1LE29724AC112AA SA-7EXSD T 575 RGZEESD Ball 1LE29724AC113AA SA-7EXSD Stock Model Introduction General Purpose Duty Duty Purpose Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V All RGZEESD motors will be discontinued when present stock is depleted DOE#CC032A Low Voltage AC Selection and Pricing Guide 3-29 Dimensions

86 - TEFC Introduction General Purpose RGZEESD HP RPM Frame Voltage Type DE Bearing List Price $ Mult. Sym. NEMA Premium Efficiency FL Amps* FL Nom. Eff. (%) Weight (lbs) TS 460 RGZEESD Ball 1LE29723DA212AA SA-7EXSD TS 575 RGZEESD Ball 1LE29723DA213AA SA-7EXSD TS 460 RGZEESD Ball 1LE29723DB212AA SA-7EXSD T 460 RGZEESD Ball 1LE29723CB212AA SA-7EXSD TS 575 RGZEESD Ball 1LE29723DB213AA SA-7EXSD T 575 RGZEESD Ball 1LE29723CB213AA SA-7EXSD T 460 RGZEESD Ball 1LE29724AC212AA SA-7EXSD T 575 RGZEESD Ball 1LE29724AC213AA SA-7EXSD TS 460 RGZEESD Ball 1LE29724BA212AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724BA213AA SA-7EXSD TS 460 RGZEESD Ball 1LE29724BB212AA SA-7EXSD T 460 RGZEESD Ball 1LE29724AB212AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724BB213AA SA-7EXSD T 575 RGZEESD Ball 1LE29724AB213AA SA-7EXSD TS 460 RGZEESD Ball 1LE29724DC112AA SA-7EXSD T 460 RGZEESD Roller 1LE29724CC112AA SA-7EXSD B444T 460 RGZEESD Ball 1LE29724EC112AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724DC113AA SA-7EXSD T 575 RGZEESD Roller 1LE29724CC113AA SA-7EXSD B444T 575 RGZEESD Ball 1LE29724EC113AA SA-7EXSD TS 460 RGZEESD Ball 1LE29724DA112AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724DA113AA SA-7EXSD TS 460 RGZEESD Ball 1LE29724DB112AA SA-7EXSD T 460 RGZEESD Roller 1LE29724CB112AA SA-7EXSD B444T 460 RGZEESD Ball 1LE29724EB112AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724DB113AA SA-7EXSD T 575 RGZEESD Roller 1LE29724CB113AA SA-7EXSD B444T 575 RGZEESD Ball 1LE29724EB113AA SA-7EXSD TS 460 RGZEESD Ball 1LE29724DC212AA SA-7EXSD T 460 RGZEESD Roller 1LE29724CC212AA SA-7EXSD B445T 460 RGZEESD Ball 1LE29724EC212AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724DC213AA SA-7EXSD T 575 RGZEESD Roller 1LE29724CC213AA SA-7EXSD B445T 575 RGZEESD Ball 1LE29724EC213AA SA-7EXSD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V All RGZEESD motors will be discontinued when present stock is depleted Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Stock Model Dimensions Duty Duty Purpose Low Voltage AC Selection and Pricing Guide DOE#CC032A

87 - TEFC RGZEESD HP RPM Frame Voltage Type DOE#CC032A DE Bearing List Price $ Mult. Sym. NEMA Premium Efficiency FL Amps* FL Nom. Eff. (%) Weight (lbs) TS 460 RGZEESD Ball 1LE29724DA212AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724DA213AA SA-7EXSD TS 460 RGZEESD Ball 1LE29724DB212AA SA-7EXSD T 460 RGZEESD Roller 1LE29724CB212AA SA-7EXSD B445T 460 RGZEESD Ball 1LE29724EB212AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724DB213AA SA-7EXSD T 575 RGZEESD Roller 1LE29724CB213AA SA-7EXSD B445T 575 RGZEESD Ball 1LE29724EB213AA SA-7EXSD TS 460 RGZEESD Ball 1LE29724DC312AA SA-7EXSD T 460 RGZEESD Roller 1LE29724CC312AA SA-7EXSD B447T 460 RGZEESD Ball 1LE29724EC312AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724DC313AA SA-7EXSD T 575 RGZEESD Roller 1LE29724CC313AA SA-7EXSD B447T 575 RGZEESD Ball 1LE29724EC313AA SA-7EXSD TS 460 RGZEESD Ball 1LE29724DA312AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724DA313AA SA-7EXSD TS 460 RGZEESD Ball 1LE29724DB312AA SA-7EXSD T 460 RGZEESD Roller 1LE29724CB312AA SA-7EXSD B447T 460 RGZEESD Ball 1LE29724EB312AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724DB313AA SA-7EXSD T 575 RGZEESD Roller 1LE29724CB313AA SA-7EXSD B447T 575 RGZEESD Ball 1LE29724EB313AA SA-7EXSD TS 460 RGZEESD Ball 1LE29724DC512AA SA-7EXSD T 460 RGZEESD Roller 1LE29724CC512AA SA-7EXSD B449T 460 RGZEESD Ball 1LE29724EC512AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724DC513AA SA-7EXSD T 575 RGZEESD Roller 1LE29724CC513AA SA-7EXSD B449T 575 RGZEESD Ball 1LE29724EC513AA SA-7EXSD TS 460 RGZEESD Ball 1LE29724DA512AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724DA513AA SA-7EXSD TS 460 RGZEESD Ball 1LE29724DB512AA SA-7EXSD T 460 RGZEESD Roller 1LE29724CB512AA SA-7EXSD B449T 460 RGZEESD Ball 1LE29724EB512AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724DB513AA SA-7EXSD T 575 RGZEESD Roller 1LE29724CB513AA SA-7EXSD B449T 575 RGZEESD Ball 1LE29724EB513AA SA-7EXSD TS 460 RGZEESD Ball 1LE29724DC612AA SA-7EXSD T 460 RGZEESD Roller 1LE29724CC612AA SA-7EXSD B449T 460 RGZEESD Ball 1LE29724EC612AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724DC613AA SA-7EXSD T 575 RGZEESD Roller 1LE29724CC613AA SA-7EXSD B449T 575 RGZEESD Ball 1LE29724EC613AA SA-7EXSD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V All RGZEESD motors will be discontinued when present stock is depleted Meets or Exceeds Energy Independence & Security Act Efficiency Levels Low Voltage AC Selection and Pricing Guide Stock Model 3-31 Introduction General Purpose Duty Duty Purpose Dimensions

88 - TEFC RGZEESD HP RPM Frame Voltage Type DE Bearing List Price $ Mult. Sym. NEMA Premium Efficiency FL Amps* FL Nom. Eff. (%) Weight (lbs) TS 460 RGZEESD Ball 1LE29724DA612AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724DA613AA SA-7EXSD TS 460 RGZEESD Ball 1LE29724DB612AA SA-7EXSD T 460 RGZEESD Roller 1LE29724CB612AA SA-7EXSD B449T 460 RGZEESD Ball 1LE29724EB612AA SA-7EXSD TS 575 RGZEESD Ball 1LE29724DB613AA SA-7EXSD T 575 RGZEESD Roller 1LE29724CB613AA SA-7EXSD B449T 575 RGZEESD Ball 1LE29724EB613AA SA-7EXSD S449LS 460 RGZEESD Roller 1LE29724FC112AA SA-7EXSD S449LS 575 RGZEESD Roller 1LE29724FC113AA SA-7EXSD S449SS 460 RGZEESD Ball 1LE29724GA112AA SA-7EXSD S449SS 575 RGZEESD Ball 1LE29724GA113AA SA-7EXSD S449SS 460 RGZEESD Ball 1LE29724GB212AA SA-7EXSD S449LS 460 RGZEESD Roller 1LE29724FB212AA SA-7EXSD S449SS 575 RGZEESD Ball 1LE29724GB213AA SA-7EXSD S449LS 575 RGZEESD Roller 1LE29724FB213AA SA-7EXSD S449SS 460 RGZEESD Ball 1LE29724GA312AA SA-7EXSD S449SS 575 RGZEESD Ball 1LE29724GA313AA SA-7EXSD S449SS 460 RGZEESD Ball 1LE29724GB312AA SA-7EXSD S449LS 460 RGZEESD Roller 1LE29724FB312AA SA-7EXSD S449SS 575 RGZEESD Ball 1LE29724GB313AA SA-7EXSD S449LS 575 RGZEESD Roller 1LE29724FB313AA SA-7EXSD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V All RGZEESD motors will be discontinued when present stock is depleted Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Stock Model Dimensions Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide DOE#CC032A

89 / IEEE TEFC severe duty/ieee 841 TEFC motors are available in two configurations they exceed NEMA Premium efficiency with our exclusive, leading-edge, die cast copper rotor design or meet NEMA Premium efficiency with our die cast aluminum rotor design. They also exceed IEEE standards for high performance, rugged construction and long service life for the most demanding applications. They are ideal for use in chemical processing, mining, foundry, pulp and paper, waste management and petro/ chemical applications. Specifications 1 to 400 HP 1.15 service factor, 40ºC ambient 3600, 1800, 1200 or 900 RPM 3-phase, 60 Hz; 460 and 575 volt operation Meets or exceeds NEMA Premium efficiency standards Class F insulation, Class B temperature 1.0SF NEMA design B (except as noted), continuous duty 0.06 IPS vibration / 0.005" foot flatness Meets IP55 & IEEE T to S449T Features for Long Life Frame & Bearing Housings Cast iron construction for exceptional structural integrity & corrosion resistance, equipped with integrally cast feet. Condensation T-drains Provided. Lifting eyebolts are included with motors > 75 lbs. Specifications table begins on the next page Rotor Frame size 143T 256T offer Siemens exclusive, leading edge, die cast copper rotor design which provides industry leading efficiencies, exceeding NEMA Premium. Die cast aluminum rotor motors, which meet the NEMA Premium efficiency levels, are dynamically balanced for extended bearing life. Rotor assembly includes a high-strength carbon steel (C1045) shaft for maximum rotor performance. Stator/Windings Manufactured with premium electrical-grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross-section reduces resistance and lowers stator losses. Insulation Proprietary inverterrated Class F non-hygroscopic insulation system with NEMA Class B temperature 1.0SF provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical shock. This insulation system meets or exceeds NEMA MG1-2006, Part 31 making all motors suitable for operation with adjustable frequency drives. Cooling A bi-directional, nonsparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves air flow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes. Bearings Regreasable, oversized single shielded with cast iron inner caps. Alemite grease inlet fittings and automatic grease relief fittings for ease of routine maintenance. Inpro/Seal bearing isolators are standard on bearing housings. Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 NEMA Premium Efficiency Lubrication A specially formulated, high temperature tested, polyurea based grease is used to provide more than four times the lubrication life of other greases. Seamless, grease filled lubrication pipes are included. Oversized Conduit Box Cast iron construction that is larger than industry standards, diagonally-split, neoprene gasketed and rotatable in 90º increments for quick and easy connections. A ground lug is provided. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, polycarbonate fan, zinc-plated hardware, epoxy enamel paint and embossed stainless steel nameplate resist rust and corrosion. Modifiable & Siemens motors are available with a wide variety of modifications & custom designs to meet your specific motor needs. Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 3-33 Dimensions

90 Introduction General Purpose Duty Duty Purpose Dimensions / IEEE TEFC (Aluminum Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) T 460 Ball 1LE24211AA112AA3 512 SD T 575 Ball 1LE24211AA113AA3 512 SD T 460 Ball 1LE24211AB212AA3 496 SD T 575 Ball 1LE24211AB213AA3 496 SD T 460 Ball 1LE24211AC312AA3 584 SD T 575 Ball 1LE24211AC313AA3 584 SD T 460 Ball 1LE24211CD112AA3 948 SD T 575 Ball 1LE24211CD113AA3 948 SD T 460 Ball 1LE24211AA212AA3 513 SD T 575 Ball 1LE24211AA213AA3 513 SD T 460 Ball 1LE24211AB312AA3 535 SD T 575 Ball 1LE24211AB313AA3 535 SD T 460 Ball 1LE24211CC112AA3 655 SD T 575 Ball 1LE24211CC113AA3 655 SD T 460 Ball 1LE24211CD312AA SD T 575 Ball 1LE24211CD313AA SD T 460 Ball 1LE24211AA312AA3 589 SD T 575 Ball 1LE24211AA313AA3 589 SD T 460 Ball 1LE24211AB412AA3 572 SD T 575 Ball 1LE24211AB413AA3 572 SD T 460 Ball 1LE24211CC312AA3 697 SD T 575 Ball 1LE24211CC313AA3 697 SD T 460 Ball 1LE24212AD112AA SD T 575 Ball 1LE24212AD113AA SD T 460 Ball 1LE24211CA112AA3 617 SD T 575 Ball 1LE24211CA113AA3 617 SD T 460 Ball 1LE24211CB112AA3 591 SD T 575 Ball 1LE24211CB113AA3 591 SD T 460 Ball 1LE24212AC112AA3 879 SD T 575 Ball 1LE24212AC113AA3 879 SD T 460 Ball 1LE24212AD212AA SD T 575 Ball 1LE24212AD213AA SD T 460 Ball 1LE24211CA312AA3 751 SD T 575 Ball 1LE24211CA313AA3 751 SD T 460 Ball 1LE24211CB312AA3 673 SD T 575 Ball 1LE24211CB313AA3 673 SD T 460 Ball 1LE24212AC212AA SD T 575 Ball 1LE24212AC213AA SD T 460 Ball 1LE24212BD112AA SD T 575 Ball 1LE24212BD113AA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Frames available after RGZEESDX stock motors are depleted 1 CW Rotation facing opposite drive end 2 NEMA Design A Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Stock Model Low Voltage AC Selection and Pricing Guide DOE#CC032A

91 / IEEE TEFC (Aluminum Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) T 460 Ball 1LE24212AA112AA3 926 SD T 575 Ball 1LE24212AA113AA3 926 SD T 460 Ball 1LE24212AB112AA3 899 SD T 575 Ball 1LE24212AB113AA3 899 SD T 460 Ball 1LE24212BC112AA SD T 575 Ball 1LE24212BC113AA SD T 460 Ball 1LE24212BD212AA SD T 575 Ball 1LE24212BD213AA SD T 460 Ball 1LE24212AA212AA SD T 575 Ball 1LE24212AA213AA SD T 460 Ball 1LE24212AB212AA SD T 575 Ball 1LE24212AB213AA SD T 460 Ball 1LE24212BC212AA SD T 575 Ball 1LE24212BC213AA SD T 460 Ball 1LE24212CD112AA SD T 575 Ball 1LE24212CD113AA SD T 460 Ball 1LE24212BA112AA SD T 575 Ball 1LE24212BA113AA SD T 460 Ball 1LE24212BB112AA SD T 575 Ball 1LE24212BB113AA SD T 460 Ball 1LE24212CC112AA SD T 575 Ball 1LE24212CC113AA SD T 460 Ball 1LE24212CD212AA SD T 575 Ball 1LE24212CD213AA SD T 460 Ball 1LE24212BA212AA SD T 575 Ball 1LE24212BA213AA SD T 460 Ball 1LE24212BB212AA SD T 575 Ball 1LE24212BB213AA SD T 460 Ball 1LE24212CC212AA SD T 575 Ball 1LE24212CC213AA SD T 460 Ball 1LE24213AD112AA SD T 575 Ball 1LE24213AD113AA SD TS 460 Ball 1LE24212DA112AA SD TS 575 Ball 1LE24212DA113AA SD T 460 Ball 1LE24212CB112AA SD T 575 Ball 1LE24212CB113AA SD TS 460 Ball 1LE24212DB112AA SD TS 575 Ball 1LE24212DB113AA SD T 460 Ball 1LE24213AC112AA SD T 575 Ball 1LE24213AC113AA SD T 460 Ball 1LE24213AD212AA SD T 575 Ball 1LE24213AD213AA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Frames available after RGZEESDX stock motors are depleted 1 CW Rotation facing opposite drive end 2 NEMA Design A DOE#CC032A Meets or Exceeds Energy Independence & Security Act Efficiency Levels Low Voltage AC Selection and Pricing Guide Stock Model 3-35 Introduction General Purpose Duty Duty Purpose Dimensions

92 Introduction General Purpose Duty Duty Purpose Dimensions / IEEE TEFC (Aluminum Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) TS 460 Ball 1LE24212DA212AA SD TS 575 Ball 1LE24212DA213AA SD T 460 Ball 1LE24212CB212AA SD T 575 Ball 1LE24212CB213AA SD TS 460 Ball 1LE24212DB212AA SD TS 575 Ball 1LE24212DB213AA SD T 460 Ball 1LE24213AC212AA SD T 575 Ball 1LE24213AC213AA SD T 460 Ball 1LE24213CD112AA SD T 575 Ball 1LE24213CD113AA SD TS 460 Ball 1LE24213BA112AA SD TS 575 Ball 1LE24213BA113AA SD T 460 Ball 1LE24213AB112AA SD T 575 Ball 1LE24213AB113AA SD TS 460 Ball 1LE24213BB112AA SD TS 575 Ball 1LE24213BB113AA SD T 460 Ball 1LE24213CC112AA SD T 575 Ball 1LE24213CC113AA SD T 460 Ball 1LE24213CD212AA SD T 575 Ball 1LE24213CD213AA SD TS 460 Ball 1LE24213BA212AA SD TS 575 Ball 1LE24213BA213AA SD T 460 Ball 1LE24213AB212AA SD T 575 Ball 1LE24213AB213AA SD TS 460 Ball 1LE24213BB212AA SD TS 575 Ball 1LE24213BB213AA SD T 460 Ball 1LE24213CC212AA SD T 575 Ball 1LE24213CC213AA SD T 460 Ball 1LE24214AD112AA SD T 575 Ball 1LE24214AD113AA SD TS 460 Ball 1LE24213DA112AA SD TS 575 Ball 1LE24213DA113AA SD T 460 Ball 1LE24213CB112AA SD T 575 Ball 1LE24213CB113AA SD TS 460 Ball 1LE24213DB112AA SD TS 575 Ball 1LE24213DB113AA SD T 460 Ball 1LE24214AC112AA SD T 575 Ball 1LE24214AC113AA SD T 460 Ball 1LE24214AD212AA SD T 575 Ball 1LE24214AD213AA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Frames available after RGZEESDX stock motors are depleted 1 CW Rotation facing opposite drive end 2 NEMA Design A Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Stock Model Low Voltage AC Selection and Pricing Guide DOE#CC032A

93 / IEEE TEFC (Aluminum Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) TS 460 Ball 1LE24213DA212AA SD TS 575 Ball 1LE24213DA213AA SD T 460 Ball 1LE24213CB212AA SD T 575 Ball 1LE24213CB213AA SD TS 460 Ball 1LE24213DB212AA SD TS 575 Ball 1LE24213DB213AA SD T 460 Ball 1LE24214AC212AA SD T 575 Ball 1LE24214AC213AA SD T 460 Roller 1LE24214CD112AA SD TS 460 Ball 1LE24214DD112AA SD B444T 460 Ball 1LE24214ED112AA SD T 575 Roller 1LE24214CD113AA SD TS 575 Ball 1LE24214DD113AA SD B444T 575 Ball 1LE24214ED113AA SD TS 460 Ball 1LE24214BA212AA SD TS 575 Ball 1LE24214BA213AA SD T 460 Ball 1LE24214AB212AA SD T 575 Ball 1LE24214AB213AA SD TS 460 Ball 1LE24214BB212AA SD TS 575 Ball 1LE24214BB213AA SD T 460 Roller 1LE24214CC112AA SD T 575 Roller 1LE24214CC113AA SD TS 460 Ball 1LE24214DC112AA SD TS 575 Ball 1LE24214DC113AA SD B444T 460 Ball 1LE24214EC112AA SD B444T 575 Ball 1LE24214EC113AA SD T 460 Roller 1LE24214CD212AA SD TS 460 Ball 1LE24214DD212AA SD B445T 460 Ball 1LE24214ED212AA SD T 575 Roller 1LE24214CD213AA SD TS 575 Ball 1LE24214DD213AA SD B445T 575 Ball 1LE24214ED213AA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Frames available after RGZEESDX stock motors are depleted 1 CW Rotation facing opposite drive end 2 NEMA Design A Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Stock Model Introduction General Purpose Duty Duty Purpose DOE#CC032A Low Voltage AC Selection and Pricing Guide 3-37 Dimensions

94 Introduction General Purpose Duty Duty Purpose Dimensions / IEEE TEFC (Aluminum Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) TS 460 Ball 1LE24214DA112AA SD TS 575 Ball 1LE24214DA113AA SD T 460 Roller 1LE24214CB112AA SD T 575 Roller 1LE24214CB113AA SD TS 460 Ball 1LE24214DB112AA SD TS 575 Ball 1LE24214DB113AA SD B444T 460 Ball 1LE24214EB112AA SD B444T 575 Ball 1LE24214EB113AA SD T 460 Roller 1LE24214CC212AA SD T 575 Roller 1LE24214CC213AA SD TS 460 Ball 1LE24214DC212AA SD TS 575 Ball 1LE24214DC213AA SD B445T 460 Ball 1LE24214EC212AA SD B445T 575 Ball 1LE24214EC213AA SD T 460 Roller 1LE24214CD312AA SD TS 460 Ball 1LE24214DD312AA SD B447T 460 Ball 1LE24214ED312AA SD T 575 Roller 1LE24214CD313AA SD TS 575 Ball 1LE24214DD313AA SD B447T 575 Ball 1LE24214ED313AA SD TS 460 Ball 1LE24214DA212AA SD TS 575 Ball 1LE24214DA213AA SD T 460 Roller 1LE24214CB212AA SD T 575 Roller 1LE24214CB213AA SD TS 460 Ball 1LE24214DB212AA SD TS 575 Ball 1LE24214DB213AA SD B445T 460 Ball 1LE24214EB212AA SD B445T 575 Ball 1LE24214EB213AA SD T 460 Roller 1LE24214CC312AA SD T 575 Roller 1LE24214CC313AA SD TS 460 Ball 1LE24214DC312AA SD TS 575 Ball 1LE24214DC313AA SD B447T 460 Ball 1LE24214EC312AA SD B447T 575 Ball 1LE24214EC313AA SD T 460 Roller 1LE24214CD512AA SD TS 460 Ball 1LE24214DD512AA SD B449T 460 Ball 1LE24214ED512AA SD T 575 Roller 1LE24214CD513AA SD TS 575 Ball 1LE24214DD513AA SD B449T 575 Ball 1LE24214ED513AA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Frames available after RGZEESDX stock motors are depleted 1 CW Rotation facing opposite drive end 2 NEMA Design A Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Stock Model Low Voltage AC Selection and Pricing Guide DOE#CC032A

95 / IEEE TEFC (Aluminum Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DOE#CC032A DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) TS 460 Ball 1LE24214DA312AA SD TS 575 Ball 1LE24214DA313AA SD T 460 Roller 1LE24214CB312AA SD T 575 Roller 1LE24214CB313AA SD TS 460 Ball 1LE24214DB312AA SD TS 575 Ball 1LE24214DB313AA SD B447T 460 Ball 1LE24214EB312AA SD B447T 575 Ball 1LE24214EB313AA SD T 460 Roller 1LE24214CC512AA SD T 575 Roller 1LE24214CC513AA SD TS 460 Ball 1LE24214DC512AA SD TS 575 Ball 1LE24214DC513AA SD B449T 460 Ball 1LE24214EC512AA SD B449T 575 Ball 1LE24214EC513AA SD S449LS 460 Roller 1LE24214FD112AA SD S449LS 575 Roller 1LE24214FD113AA SD TS 460 Ball 1LE24214DA512AA SD TS 575 Ball 1LE24214DA513AA SD T 460 Roller 2 1LE24214CB512AA SD T 575 Roller 2 1LE24214CB513AA SD TS 460 Ball 1 1LE24214DB512AA SD TS 575 Ball 1 1LE24214DB513AA SD B449T 460 Ball 1 1LE24214EB512AA SD B449T 575 Ball 1 1LE24214EB513AA SD T 460 Roller 2 1LE24214CC612AA SD T 575 Roller 2 1LE24214CC613AA SD TS 460 Ball 1 1LE24214DC612AA SD TS 575 Ball 1 1LE24214DC613AA SD B449T 460 Ball 1 1LE24214EC612AA SD B449T 575 Ball 1 1LE24214EC613AA SD S449LS 460 Roller 1LE24214FD212AA SD S449LS 575 Roller 1LE24214FD213AA SD TS 460 Ball 1 1LE24214DA612AA SD TS 575 Ball 1 1LE24214DA613AA SD S449LS 460 Roller 1,2 1LE24214FB112AA SD S449LS 575 Roller 1,2 1LE24214FB113AA SD S449SS 460 Ball 1,2 1LE24214GB112AA SD S449SS 575 Ball 1,2 1LE24214GB113AA SD S449LS 460 Roller 1,2 1LE24214FC112AA SD S449SS 460 Ball 1,2 1LE24214GC112AA SD S449LS 575 Roller 1,2 1LE24214FC113AA SD S449SS 575 Ball 1,2 1LE24214GC113AA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Frames available after RGZEESDX stock motors are depleted 1 CW Rotation facing opposite drive end 2 NEMA Design A Meets or Exceeds Energy Independence & Security Act Efficiency Levels Low Voltage AC Selection and Pricing Guide Stock Model 3-39 Introduction General Purpose Duty Duty Purpose Dimensions

96 / IEEE TEFC (Aluminum Rotor) Introduction HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) S449SS 460 Ball 1 1LE24214GA112AA SD S449SS 575 Ball 1 1LE24214GA113AA SD S449LS 460 Roller 1 1LE24214FB212AA SD S449LS 575 Roller 1 1LE24214FB213AA SD S449SS 460 Ball 1 1LE24214GB212AA SD S449SS 575 Ball 1 1LE24214GB213AA SD S449SS 460 Ball 1 1LE24214GA312AA SD S449SS 575 Ball 1 1LE24214GA313AA SD S449LS 460 Roller 1 1LE24214FB312AA SD S449LS 575 Roller 1 1LE24214FB313AA SD S449SS 460 Ball 1 1LE24214GB312AA SD S449SS 575 Ball 1 1LE24214GB313AA SD Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Frames available after RGZEESDX stock motors are depleted 1 CW Rotation facing opposite drive end 2 NEMA Design A Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Stock Model Dimensions General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide DOE#CC032A

97 / IEEE TEFC (Copper Rotor) HP RPM Frame Voltage Type Horizontal, Foot Mounted DE Bearing NEMA Premium Efficiency Plus List Price $ Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) T 460 Ball 1LE24111AB212AA3 579 SD T 575 Ball 1LE24111AB213AA3 579 SD T 460 Ball 1LE24111AC312AA3 681 SD T 575 Ball 1LE24111AC313AA3 681 SD T 460 Ball 1LE24111AA212AA3 599 SD T 575 Ball 1LE24111AA213AA3 599 SD T 460 Ball 1LE24111AB312AA3 624 SD T 575 Ball 1LE24111AB313AA3 624 SD T 460 Ball 1LE24111AA312AA3 687 SD T 575 Ball 1LE24111AA313AA3 687 SD T 460 Ball 1LE24111AB412AA3 668 SD T 575 Ball 1LE24111AB413AA3 668 SD T 460 Ball 1LE24111CA112AA3 720 SD T 575 Ball 1LE24111CA113AA3 720 SD T 460 Ball 1LE24111CB112AA3 690 SD T 575 Ball 1LE24111CB113AA3 690 SD T 460 Ball 1LE24112AC112AA SD T 575 Ball 1LE24112AC113AA SD T 460 Ball 1LE24111CA312AA3 876 SD T 575 Ball 1LE24111CA313AA3 876 SD T 460 Ball 1LE24111CB312AA3 785 SD T 575 Ball 1LE24111CB313AA3 785 SD T 460 Ball 1LE24112AC212AA SD T 575 Ball 1LE24112AC213AA SD T 460 Ball 1LE24112AA112AA SD T 575 Ball 1LE24112AA113AA SD T 460 Ball 1LE24112AB112AA SD T 575 Ball 1LE24112AB113AA SD T 460 Ball 1LE24112BC112AA SD T 575 Ball 1LE24112BC113AA SD T 460 Ball 1LE24112AA212AA SD T 575 Ball 1LE24112AA213AA SD T 460 Ball 1LE24112AB212AA SD T 575 Ball 1LE24112AB213AA SD T 460 Ball 1LE24112BC212AA SD T 575 Ball 1LE24112BC213AA SD T 460 Ball 1LE24112BA112AA SD T 575 Ball 1LE24112BA113AA SD T 460 Ball 1LE24112BB112AA SD T 575 Ball 1LE24112BB113AA SD T 460 Ball 1LE24112BA212AA SD T 575 Ball 1LE24112BA213AA SD T 460 Ball 1LE24112BB212AA SD T 575 Ball 1LE24112BB213AA SD Prices and specifications are subject to change without notice Stock availability subject to sale DOE#CC032A delivery for stocked motors only *FL Amps at 460V or 575V Exceeds Energy Independence & Security Act Efficiency Levels Low Voltage AC Selection and Pricing Guide Stock Model 3-41 Introduction General Purpose Duty Duty Purpose Dimensions

98 Introduction General Purpose Duty Duty Purpose / IEEE TEFC RGZEESDX RGZEESDX severe duty IEEE 841 TEFC motors meet or exceed NEMA Premium efficiencies. They also exceed IEEE standards for high performance, rugged construction and long service life for the most demanding applications. They are ideal for use in chemical processing, mining, foundry, pulp and paper, waste management and petro/ chemical applications. Specifications 25 to 400 HP 1.15 service factor, 40ºC ambient 3600, 1800, 1200 or 900 RPM 3-phase, 60 Hz; 460 and 575 volt operation Meets or exceeds NEMA Premium efficiency standards Class F insulation, Class B temperature 1.0SF NEMA design B (except as noted), continuous duty 0.06 IPS vibration / 0.005" foot flatness Meets IP55 & IEEE T to S449 frames Features for Long Life Frame & Bearing Housings Cast iron construction for exceptional structural integrity & corrosion resistance, equipped with integrally cast feet. Condensation T-drains provided. Lifting eyebolts are included with motors > 75 lbs. Specifications table begins on the next page Rotor A unique, low loss, die cast aluminum rotor. Each rotor assembly is dynamically balanced for extended bearing life, and includes a high-strength carbon steel(c1045) shaft for maximum rotor performance. Stator/Windings Manufactured with premium electrical-grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross-section reduces resistance and lowers stator losses. Insulation Proprietary inverterrated Class F non-hygroscopic insulation system with NEMA Class B temperature 1.0SF provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical shock. This insulation system meets or exceeds NEMA MG1-2006, Part 31 making all motors suitable for operation with adjustable frequency drives. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves air flow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes. Bearings Regreasable, oversized single shielded with cast iron inner caps. Alemite grease inlet fittings and automatic grease relief fittings for ease of routine maintenance. Inpro/Seal bearing isolators are standard on bearing housings. Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 NEMA Premium Efficiency Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. Seamless, grease filled lubrication pipes an automatic grease relief fittings are included. Oversized Conduit Box Cast iron construction that is larger than industry standards, diagonally-split, neoprene gasketed and rotatable in 90º increments for quick and easy connections. Includes a ground lug. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, polycarbonate fan, zinc-plated hardware, epoxy enamel paint and embossed stainless steel nameplate resist rust and corrosion. Modifiable & Siemens motors are available with a wide variety of modifications and custom designs to meet your specific motor needs. Dimensions Low Voltage AC Selection and Pricing Guide

99 / IEEE TEFC RGZEESDX HP RPM Frame Voltage Type DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 FL Amps* FL Nom. Eff. (%) Weight (lbs) T 460 RGZEESDX Ball 1LE29822CD112AA SA-7IEE T 575 RGZEESDX Ball 1LE29822CD113AA SA-7IEE T 460 RGZEESDX Ball 1LE29822CC112AA SA-7IEE T 575 RGZEESDX Ball 1LE29822CC113AA SA-7IEE T 460 RGZEESDX Ball 1LE29822CD212AA SA-7IEE T 575 RGZEESDX Ball 1LE29822CD213AA SA-7IEE T 460 RGZEESDX Ball 1LE29822CC212AA SA-7IEE T 575 RGZEESDX Ball 1LE29822CC213AA SA-7IEE T 460 RGZEESDX Ball 1LE29823AD112AA SA-7IEE T 575 RGZEESDX Ball 1LE29823AD113AA SA-7IEE TS 460 RGZEESDX Ball 1LE29822DA112AA SA-7IEE TS 575 RGZEESDX Ball 1LE29822DA113AA SA-7IEE T 460 RGZEESDX Ball 1LE29822CB112AA SA-7IEE T 575 RGZEESDX Ball 1LE29822CB113AA SA-7IEE TS 460 RGZEESDX Ball 1LE29822DB112AA SA-7IEE TS 575 RGZEESDX Ball 1LE29822DB113AA SA-7IEE T 460 RGZEESDX Ball 1LE29823AC112AA SA-7IEE T 575 RGZEESDX Ball 1LE29823AC113AA SA-7IEE T 460 RGZEESDX Ball 1LE29823AD212AA SA-7IEE T 575 RGZEESDX Ball 1LE29823AD213AA SA-7IEE TS 460 RGZEESDX Ball 1LE29822DA212AA SA-7IEE TS 575 RGZEESDX Ball 1LE29822DA213AA SA-7IEE T 460 RGZEESDX Ball 1LE29822CB212AA SA-7IEE T 575 RGZEESDX Ball 1LE29822CB213AA SA-7IEE TS 460 RGZEESDX Ball 1LE29822DB212AA SA-7IEE TS 575 RGZEESDX Ball 1LE29822DB213AA SA-7IEE T 460 RGZEESDX Ball 1LE29823AC212AA SA-7IEE T 575 RGZEESDX Ball 1LE29823AC213AA SA-7IEE T 460 RGZEESDX Ball 1LE29823CD112AA SA-7IEE T 575 RGZEESDX Ball 1LE29823CD113AA SA-7IEE TS 460 RGZEESDX Ball 1LE29823BA112AA SA-7IEE TS 575 RGZEESDX Ball 1LE29823BA113AA SA-7IEE T 460 RGZEESDX Ball 1LE29823AB112AA SA-7IEE T 575 RGZEESDX Ball 1LE29823AB113AA SA-7IEE TS 460 RGZEESDX Ball 1LE29823BB112AA SA-7IEE TS 575 RGZEESDX Ball 1LE29823BB113AA SA-7IEE T 460 RGZEESDX Ball 1LE29823CC112AA SA-7IEE T 575 RGZEESDX Ball 1LE29823CC113AA SA-7IEE T 460 RGZEESDX Ball 1LE29823CD212AA SA-7IEE T 575 RGZEESDX Ball 1LE29823CD213AA SA-7IEE Stock Model Introduction General Purpose Duty Duty Purpose Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only FL Amps at 460V or 575V All RGZEESDX motors will be discontinued when present stock is depleted DOE#CC032A Low Voltage AC Selection and Pricing Guide 3-43 Dimensions

100 Introduction General Purpose Duty Duty Purpose Dimensions / IEEE TEFC RGZEESDX HP RPM Frame Voltage Type DE Bearing Low Voltage AC Selection and Pricing Guide List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) TS 460 RGZEESDX Ball 1LE29823BA212AA SA-7IEE TS 575 RGZEESDX Ball 1LE29823BA213AA SA-7IEE T 460 RGZEESDX Ball 1LE29823AB212AA SA-7IEE T 575 RGZEESDX Ball 1LE29823AB213AA SA-7IEE TS 460 RGZEESDX Ball 1LE29823BB212AA SA-7IEE TS 575 RGZEESDX Ball 1LE29823BB213AA SA-7IEE T 460 RGZEESDX Ball 1LE29823CC212AA SA-7IEE T 575 RGZEESDX Ball 1LE29823CC213AA SA-7IEE T 460 RGZEESDX Ball 1LE29824AD112AA SA-7IEE T 575 RGZEESDX Ball 1LE29824AD113AA SA-7IEE TS 460 RGZEESDX Ball 1LE29823DA112AA SA-7IEE TS 575 RGZEESDX Ball 1LE29823DA113AA SA-7IEE T 460 RGZEESDX Ball 1LE29823CB112AA SA-7IEE T 575 RGZEESDX Ball 1LE29823CB113AA SA-7IEE TS 460 RGZEESDX Ball 1LE29823DB112AA SA-7IEE TS 575 RGZEESDX Ball 1LE29823DB113AA SA-7IEE T 460 RGZEESDX Ball 1LE29824AC112AA SA-7IEE T 575 RGZEESDX Ball 1LE29824AC113AA SA-7IEE T 460 RGZEESDX Ball 1LE29824AD212AA SA-7IEE T 575 RGZEESDX Ball 1LE29824AD213AA SA-7IEE TS 460 RGZEESDX Ball 1LE29823DA212AA SA-7IEE TS 575 RGZEESDX Ball 1LE29823DA213AA SA-7IEE T 460 RGZEESDX Ball 1LE29823CB212AA SA-7IEE T 575 RGZEESDX Ball 1LE29823CB213AA SA-7IEE TS 460 RGZEESDX Ball 1LE29823DB212AA SA-7IEE TS 575 RGZEESDX Ball 1LE29823DB213AA SA-7IEE T 460 RGZEESDX Ball 1LE29824AC212AA SA-7IEE T 575 RGZEESDX Ball 1LE29824AC213AA SA-7IEE T 460 RGZEESDX Roller 1LE29824CD112AA SA-7IEE T 575 RGZEESDX Roller 1LE29824CD113AA SA-7IEE TS 460 RGZEESDX Ball 1LE29824BA212AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824BA213AA SA-7IEE T 460 RGZEESDX Ball 1LE29824AB212AA SA-7IEE T 575 RGZEESDX Ball 1LE29824AB213AA SA-7IEE TS 460 RGZEESDX Ball 1LE29824BB212AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824BB213AA SA-7IEE T 460 RGZEESDX Roller 1LE29824CC112AA SA-7IEE T 575 RGZEESDX Roller 1LE29824CC113AA SA-7IEE TS 460 RGZEESDX Ball 1LE29824DC112AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824DC113AA SA-7IEE B444T 460 RGZEESDX Ball 1LE29824EC112AA SA-7IEE B444T 575 RGZEESDX Ball 1LE29824EC113AA SA-7IEE T 460 RGZEESDX Roller 1LE29824CD212AA SA-7IEE T 575 RGZEESDX Roller 1LE29824CD213AA SA-7IEE Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V All RGZEESDX motors will be discontinued when present stock is depleted Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Stock Model DOE#CC032A

101 / IEEE TEFC RGZEESDX HP RPM Frame Voltage Type DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) TS 460 RGZEESDX Ball 1LE29824DA112AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824DA113AA SA-7IEE T 460 RGZEESDX Roller 1LE29824CB112AA SA-7IEE T 575 RGZEESDX Roller 1LE29824CB113AA SA-7IEE TS 460 RGZEESDX Ball 1LE29824DB112AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824DB113AA SA-7IEE B444T 460 RGZEESDX Ball 1LE29824EB112AA SA-7IEE B444T 575 RGZEESDX Ball 1LE29824EB113AA SA-7IEE T 460 RGZEESDX Roller 1LE29824CC212AA SA-7IEE T 575 RGZEESDX Roller 1LE29824CC213AA SA-7IEE TS 460 RGZEESDX Ball 1LE29824DC212AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824DC213AA SA-7IEE B445T 460 RGZEESDX Ball 1LE29824EC212AA SA-7IEE B445T 575 RGZEESDX Ball 1LE29824EC213AA SA-7IEE T 460 RGZEESDX Roller 1LE29824CD312AA SA-7IEE T 575 RGZEESDX Roller 1LE29824CD313AA SA-7IEE TS 460 RGZEESDX Ball 1LE29824DA212AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824DA213AA SA-7IEE T 460 RGZEESDX Roller 1LE29824CB212AA SA-7IEE T 575 RGZEESDX Roller 1LE29824CB213AA SA-7IEE TS 460 RGZEESDX Ball 1LE29824DB212AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824DB213AA SA-7IEE B445T 460 RGZEESDX Ball 1LE29824EB212AA SA-7IEE B445T 575 RGZEESDX Ball 1LE29824EB213AA SA-7IEE T 460 RGZEESDX Roller 1LE29824CC312AA SA-7IEE T 575 RGZEESDX Roller 1LE29824CC313AA SA-7IEE TS 460 RGZEESDX Ball 1LE29824DC312AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824DC313AA SA-7IEE B447T 460 RGZEESDX Ball 1LE29824EC312AA SA-7IEE B447T 575 RGZEESDX Ball 1LE29824EC313AA SA-7IEE T 460 RGZEESDX Roller 1LE29824CD512AA SA-7IEE T 575 RGZEESDX Roller 1LE29824CD513AA SA-7IEE Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V All RGZEESDX motors will be discontinued when present stock is depleted Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Stock Model Introduction General Purpose Duty Duty Purpose DOE#CC032A Low Voltage AC Selection and Pricing Guide 3-45 Dimensions

102 Introduction General Purpose Duty Duty Purpose Dimensions / IEEE TEFC RGZEESDX HP RPM Frame Voltage Type DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 FL Amps* FL Nom. Eff. (%) Weight (lbs) TS 460 RGZEESDX Ball 1LE29824DA312AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824DA313AA SA-7IEE T 460 RGZEESDX Roller 1LE29824CB312AA SA-7IEE T 575 RGZEESDX Roller 1LE29824CB313AA SA-7IEE TS 460 RGZEESDX Ball 1LE29824DB312AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824DB313AA SA-7IEE B447T 460 RGZEESDX Ball 1LE29824EB312AA SA-7IEE B447T 575 RGZEESDX Ball 1LE29824EB313AA SA-7IEE T 460 RGZEESDX Roller 1LE29824CC512AA SA-7IEE T 575 RGZEESDX Roller 1LE29824CC513AA SA-7IEE TS 460 RGZEESDX Ball 1LE29824DC512AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824DC513AA SA-7IEE B449T 460 RGZEESDX Ball 1LE29824EC512AA SA-7IEE B449T 575 RGZEESDX Ball 1LE29824EC513AA SA-7IEE S449LS 460 RGZEESDX Roller 1LE29824FD112AA SA-7IEE S449LS 575 RGZEESDX Roller 1LE29824FD113AA SA-7IEE TS 460 RGZEESDX Ball 1LE29824DA512AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824DA513AA SA-7IEE T 460 RGZEESDX Roller 1LE29824CB512AA SA-7IEE T 575 RGZEESDX Roller 1LE29824CB513AA SA-7IEE TS 460 RGZEESDX Ball 1LE29824DB512AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824DB513AA SA-7IEE B449T 460 RGZEESDX Ball 1LE29824EB512AA SA-7IEE B449T 575 RGZEESDX Ball 1LE29824EB513AA SA-7IEE T 460 RGZEESDX Roller 1LE29824CC612AA SA-7IEE T 575 RGZEESDX Roller 1LE29824CC613AA SA-7IEE TS 460 RGZEESDX Ball 1LE29824DC612AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824DC613AA SA-7IEE B449T 460 RGZEESDX Ball 1LE29824EC612AA SA-7IEE B449T 575 RGZEESDX Ball 1LE29824EC613AA SA-7IEE S449LS 460 RGZEESDX Roller 1LE29824FD212AA SA-7IEE S449LS 575 RGZEESDX Roller 1LE29824FD213AA SA-7IEE TS 460 RGZEESDX Ball 1LE29824DA612AA SA-7IEE TS 575 RGZEESDX Ball 1LE29824DA613AA SA-7IEE S449LS 460 RGZEESDX Roller 1LE29824FB112AA SA-7IEE S449LS 575 RGZEESDX Roller 1LE29824FB113AA SA-7IEE S449SS 460 RGZEESDX Ball 1LE29824GB112AA SA-7IEE S449SS 575 RGZEESDX Ball 1LE29824GB113AA SA-7IEE S449LS 460 RGZEESDX Roller 1LE29824FC112AA SA-7IEE S449LS 575 RGZEESDX Roller 1LE29824FC113AA SA-7IEE S449SS 460 RGZEESDX Ball 1LE29824GA112AA SA-7IEE S449SS 575 RGZEESDX Ball 1LE29824GA113AA SA-7IEE S449LS 460 RGZEESDX Roller 1LE29824FB212AA SA-7IEE S449LS 575 RGZEESDX Roller 1LE29824FB213AA SA-7IEE S449SS 460 RGZEESDX Ball 1LE29824GB212AA SA-7IEE S449SS 575 RGZEESDX Ball 1LE29824GB213AA SA-7IEE Stock Model Low Voltage AC Selection and Pricing Guide DOE#CC032A

103 / IEEE TEFC RGZEESDX HP RPM Frame Voltage Type DE Bearing List Price $ NEMA Premium Efficiency Mult. Sym. FL Amps* FL Nom. Eff. (%) Weight (lbs) S449SS 460 RGZEESDX Ball 1LE29824GA312AA SA-7IEE S449SS 575 RGZEESDX Ball 1LE29824GA313AA SA-7IEE S449LS 460 RGZEESDX Roller 1LE29824FB312AA SA-7IEE S449LS 575 RGZEESDX Roller 1LE29824FB313AA SA-7IEE S449SS 460 RGZEESDX Ball 1LE29824GB312AA SA-7IEE S449SS 575 RGZEESDX Ball 1LE29824GB313AA SA-7IEE Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V All RGZEESDX motors will be discontinued when present stock is depleted Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Stock Model Introduction General Purpose Duty Duty Purpose DOE#CC032A Low Voltage AC Selection and Pricing Guide 3-47 Dimensions

104 Introduction General Purpose Duty Duty Purpose Dimensions (SD ) Description Code Order Code Pos Type / Frame List Price Adder Per Frame ($) SD Altitude / Ambient Rerate/Derate Y80 Z 140-S S Assembly - Mounting & Terminal Box Position F W-1 9+R1A 16+Z W-2 9+R2A 16+Z 140-S W-3 9+R3A 16+Z 140-S S W-4 9+R4A 16+Z S W W S C C S S Bearings Sealed Ball bearings 1 L68 Z 140-S (except 2 pole, 360+ frames) Breathers & Drain Plugs T Drain SS L45 Z 140-S S Crouse Hinds - UL Approved L46 Z 280-S S Conduit Box - Main Orient 90 deg CCW J84 Z 140-S S Orient 180 deg CCW J85 Z 140-S S Orient 270 deg CCW J86 Z 140-S S Conduit Box - Auxiliary for Thermostats Condulet to Main Box J12 Z 140-S S Conduit Box - Auxiliary for Space Heaters Condulet to Main Box J52 Z 140-S S Drip Cover Drip cover w/o vertical K33 Z 140-S S lifting devices Export Packaging Sea Freight - B09 Z 140-S S Siemens Standard Flanged End Shields C-Face with Feet 2 E S C-Face without Feet G D-Flange with Feet F Grounding Provision (tapped hole on L27 Z 140-S S frame w/bolt) Hardware Stainless Steel L22 Z 140-S S Lifting Eyebolt 3 L20 Z 140 std 30 std std std std std std std std std std For further details please refer to section 8 1 Sealed Ball not available for 2 pole motors with frames > C face with fee for 440 frames, only available with ball bearings 3 Lisfting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required. S Low Voltage AC Selection and Pricing Guide

105 (SD ) Description Code Order Code Pos Type / Frame List Price Adder Per Frame ($) SD Insulation Fungus Protection C07 Z 140-S S Leads / Terminal Blocks Burndy Hydent type YA K80 Z 140-S S Sealed Leads K89 Z 140-S S Lubrication Grease Fitting / Pressure L60 Z 140-S449 std Relief Nameplate Extra M21 Z 140-S S Division 2 4 M22 Z 140-S S Change (Rerate/Derate) Y80 Z 140-S S Auxiliary Y82 Z 140-S S Protective Devices - Windings Thermostats, normally G S S closed, 2 per motor Rotation Arrow Bidirectional (not applicable K70 Z 140-S S for uni-directional motors) Clockwise (facing ODE) K71 Z 140-S S Counterclockwise (facing K72 Z 140-S S ODE) Service Factor Rerate/Derate Y80 Z 140-S S Shaft Seal Slinger & O Ring L76 Z 140-S S (4, 6, 8 Pole only) Inpro Seal / DE L79 Z 140-S Software Documentation in Spanish D05 Z 140-S S Certificate of Compliance F00 Z 140-S S Standard Transmittal F40 Z 140-S S Standard Dimension Sheet F42 Z 140-S S Conduit Box Dimension F44 Z 140-S S Sheet Wiring Diagram F45 Z 140-S S IOM F46 Z 140-S S Renewal Parts F47 Z 140-S S Sheets F49 Z 140-S S F03 Z 140-S S For further details please refer to section 8 1 Sealed Ball not available for 2 pole motors with frames > C face with fee for 440 frames, only available with ball bearings 3 Lisfting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required. S449 Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 3-49 Dimensions

106 Introduction General Purpose Duty (SD ) Description Code Order Code Pos Type / Frame List Price Adder Per Frame ($) SD Space Heater 115V, Single Phase A40 Z 140-S S V, Single Phase A41 Z 140-S S V, Single Phase, Div 2 A42 Z 140-S S V, Single Phase, Div 2 A44 Z 140-S S Testing Routine Test Report F10 Z 140-S Routine Test Report with F20 Z 140-S S Vibration Test Voltage Single Voltage - 230V 11 12& (outside leads connection only) Single Voltage - 460V (outside leads connection only) 12 12& For further details please refer to section 8 1 Sealed Ball not available for 2 pole motors with frames > C face with fee for 440 frames, only available with ball bearings 3 Lisfting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required. S449 Dimensions Duty Purpose Low Voltage AC Selection and Pricing Guide

107 (RGZ ) Description Code Order Code Pos Type / Frame List Price Adder Per Frame ($) RGZESD RGZEESD RGZEESDX Altitude / Ambient Rerate/Derate Y80 Z 280-S S S Assembly - Mounting & Terminal Box Position F W-1 9+R1A 16+Z W-2 9+R2A 16+Z 280-S S S W-3 9+R3A 16+Z 280-S S S W-4 9+R4A 16+Z W W S S S C C S S S Bearings Sealed Ball bearings 1 L68 Z 280-S S (except 2 pole, 360+ frames) Breathers & Drain Plugs T Drain SS L45 Z 280-S S S Crouse Hinds - UL L46 Z 280-S S S Approved Conduit Box - Main Orient 90 deg CCW J84 Z 280-S S S Orient 180 deg CCW J85 Z 280-S S S Orient 270 deg CCW J86 Z 280-S S S Conduit Box - Auxiliary for Thermostats Condulet to Main Box J12 Z 280-S S S Conduit Box - Auxiliary for Space Heaters Condulet to Main Box J52 Z 280-S S S Drip Cover Drip cover without K33 Z 280-S S S vertical lifting devices Export Packaging Sea Freight- Siemens B09 Z 280-S S S Standard Flanged End Shields C-Face with Feet 2 E Grounding Provision (tapped hole L27 Z 280-S S S on frame w/bolt) Hardware Stainless Steel L22 Z 280-S S S Lifting Eyebolt 3 L20 Z Standard Standard Standard 30 std std std std std std std std std std Altitude / Ambient Fungus Protection C07 Z 280-S S S For further details please refer to section 8 1 Sealed Ball bearings not available for 2 pole motors with frames > C face with feet for 440 frames, only available with ball bearings 3 Lifting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required Low Voltage AC Selection and Pricing Guide S Introduction General Purpose Duty Duty Purpose Dimensions

108 Introduction General Purpose Duty Duty Purpose Dimensions (RGZ ) Description Code Order Code Pos Type / Frame List Price Adder Per Frame ($) RGZESD RGZEESD RGZEESDX Leads / Terminal Blocks Burndy Hydent type YA K80 Z 280-S S S Sealed Leads K89 Z 280-S S S Lubrication Grease Fitting / Pressure L60 Z 280-S S449 Standard Relief Nameplate Extra M21 Z 280-S S S Division 2 4 M22 Z 280-S S S Change (Rerate/Derate) Y80 Z 280-S S S Auxiliary Y82 Z 280-S S S Protective Devices - Windings Thermostats, normally G S S S closed, 2 per motor Rotation Arrow Bidirectional (not K70 Z 280-S S S applicable for unidirectional motors) Clockwise (facing ODE) K71 Z 280-S S S Counterclockwise K72 Z 280-S S S (facing ODE) Service Factor Rerate/Derate Y80 Z 280-S S S Shaft Seal Slinger & O Ring (4, 6, 8 Pole only) L76 Z 280-S S S Inpro Seal / DE L79 Z 280-S S Inpro Seal / ODE L80 Z S Inpro Seal / Both Ends L81 Z S449 std Software Documentation in Spanish D05 Z 280-S S S Certificate of Compliance F00 Z 280-S S S Standard F40 Z 280-S S S Transmittal Standard Dimension F42 Z 280-S S S Sheet Conduit Box Dimension F44 Z 280-S S S Sheet Wiring Diagram F45 Z 280-S S S IOM F46 Z 280-S S S Renewal Parts F47 Z 280-S S S F49 Z 280-S S S Sheets F03 Z 280-S S S For further details please refer to section 8 1 Sealed Ball bearings not available for 2 pole motors with frames > C face with feet for 440 frames, only available with ball bearings 3 Lifting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required. S Low Voltage AC Selection and Pricing Guide

109 (RGZ ) Description Code Order Code Pos Type / Frame List Price Adder Per Frame ($) RGZESD RGZEESD RGZEESDX Space Heater 115V, Single Phase A40 Z 280-S S S V, Single Phase A41 Z 280-S S S V, Single Phase, A42 Z 280-S S S Div 2 230V, Single Phase, A44 Z 280-S S S Div 2 Testing Routine Test Report F10 Z 280-S S Routine Test Report with Vibration Test F20 Z 280-S S S Voltage Single Voltage - 230V (outside leads connection only) Single Voltage - 460V (outside leads connection only) & &13 For further details please refer to section 8 1 Sealed Ball bearings not available for 2 pole motors with frames > C face with feet for 440 frames, only available with ball bearings 3 Lifting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required. - 20HP HP S449 Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 3-53 Dimensions

110 Introduction General Purpose Duty Duty Purpose Options (SD ) Description Code Order Code Pos SD10 List Price Adder Per Frame ($) Assembly - Mounting & Terminal Box Position W S S W F S449 S Auxiliary boxes 1 Auxiliary conduit box location (Digit 2) Condulet on main side J 0 Z 280-S S Condulet to main J 2 Z 140-S S conduit box Auxiliary conduit box J 3 Z 280-S S to main conduit box Condulet- opposite of J 4 Z 180-S S main conduit box side Auxiliary box- opposite of main conduit box side J 5 Z 280-S S Temperature detector device (Digit 1) Select the number that corresponds with the appropriate Temperature Detector Device to create your initial 3 digital ordering code. Thermistors 0 Thermostats 1 KTY 84 Thermistor 2 Space heaters 5 Stator RTD s on J S S auxiliary conduit box on main Balance Precision M69 Z 140-S449 std Extra Precision M70 Z 140-S S Bearings Roller Instead of Ball L65 Z std std std Insulated L66 Z 140-S Insulated - ODE only L67 Z 140-S Couplings er Supplied H10 Z 140-S S Export Packaging Special B10 Z 140-S S449 cf cf cf cf cf cf cf cf cf cf cf Fans Bronze M10 Z 140-S S For further details please refer to section 9 For availability on Flanges and End shields as Options see page 9-14 S449 Dimensions Low Voltage AC Selection and Pricing Guide

111 Options (SD ) Description Code Order Code Pos SD10 List Price Adder Per Frame ($) Insulation Class H C00 Z 140-S S Vacuum Pressure Impregnation (VPI) C01 Z 140-S S Moisture/Powerhouse C04 Z 140-S S (extra dip & bake) Tropicalization C08 Z 140-S S Moisture (extra dip & bake, fungus spray) Leads / Terminal Blocks Terminal Block - 3 lead K83 Z only Leads, Special Cable Y85 Z 140-S S449 cf cf cf cf cf cf cf cf cf cf cf Length Lubrication Special Grease (High & L57 Z 140-S S Low Temp) (Mobil 28) Special Grease (Mobilith L58 Z 140-S S SHC 100) Paint Paint - 3 Part Epoxy N01 Z 140-S S (Carboline or Ameron) Paint - 2 Part Epoxy N02 Z 140-S S Standard Primer Only N03 Z 140-S S Standard Paint, Special Y60 Z 140-S S Color Special Paint, Special Color Y61 Z 140-S S449 cf cf cf cf cf cf cf cf cf cf cf For further details please refer to section 9 S449 Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 3-55 Dimensions

112 Introduction General Purpose Duty Duty Options (SD ) Description Code Order Code Pos SD10 List Price Adder Per Frame ($) Protective Devices - Windings PTC thermistors, 3 B S S embedded temperature sensors for tripping PTC thermistors, 6 C S S embedded temperature sensors for alarm and tripping KTY84-130, 2 F S S embedded temperature sensors Thermocouples, coil J S S head Winding temperature protection, Stator RTD's (coil head, 1 per phase), 100Ω Platinum, complete with auxiliary box with terminal strip opposite to main box K S S Protective Devices - Bearings Bearing thermal A51 Z 400-S S protection, Bearing RTDs with connection head and terminal block - both ends, 100Ω Platinum Shafts Carbon Steel (C4140) M57 Z 400-S S Shaft DE Special to Y50 Z 140-S S449 cf cf cf cf cf cf cf cf cf cf cf er Specifications Shaft ODE Special to Y51 Z 140-S S449 cf cf cf cf cf cf cf cf cf cf cf er Specifications NEMA Standard Short M53 Z 140-S S Shaft - ODE NEMA Standard Long Shaft - ODE M52 Z 140-S S For further details please refer to section 9 S449 Dimensions Purpose Low Voltage AC Selection and Pricing Guide

113 Options (SD ) Description Code Order Code Pos SD10 List Price Adder Per Frame ($) Software Nonstandard Dimension F43 Z 140-S S Sheet er Specific F50 Z 140-S S Sheets Special Calculated F07 Z 140-S S Testing Routine Test Report - F12 Z 140-S (Witnessed) Complete Test F15 Z 140-S S Complete Test F17 Z 140-S S (Witnessed) Calibration Test F27 Z 140-S S Electrical Duplicate - F36 Z 140-S S (Routine Test) Electrical Duplicate F37 Z 140-S S (Complete Test) Noise F30 Z 140-S S Noise (Witnessed) F32 Z 140-S S Routine Test Report F22 Z 140-S S with Vibration Test (Witnessed) Vertical Jacking Vertical Jacking M39 Z 280-S S Provision Vibration Detectors Vibraswitch Robert A66 Z 280-S S Shaw malfunction detector Model D8 120VAC Provision for vibration sensors (PMC/Beta) on D.E. & O.D.E A67 Z 280-S S For further details please refer to section 9 S449 Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 3-57 Dimensions

114 Introduction General Purpose Duty Options (SD ) Description Voltage Special Voltage V Special Voltage V Code M1Y M2Y Order Code Pos 12, 13+Z 12, 13+Z SD10 List Price Adder Per Frame ($) S S S S Part Winding Start & V, 60Hz Part Winding Start & V, 60Hz Part Winding Start & S S V, 60Hz Part Winding Start & S S V, 60Hz Wye Start - Delta Run & V, 60Hz Wye Start - Delta Run & V, 60Hz Wye Start - Delta Run & S S V, 60Hz Wye Start - Delta Run - 575V, 60Hz 33 12& S S For further details please refer to section 9 S449 Dimensions Duty Purpose Low Voltage AC Selection and Pricing Guide

115 Duty - TEFC RGZZESD - Class I, Group D, Class II, Groups F & G, Division 1 RGZZESD high efficiency explosionproof motors are UL listed for dust ignition proof environments, and are suitable for use in Class I, Group D, Class II, Groups F & G, Division 1 hazardous areas. They are ideal for use in applications such as chemical processing, grain handling & pulp and paper. Specifications 1 to 300 HP 1.0 service factor, 40ºC ambient T3B temperature code (T3C / Group C & D available as a custom option) 900, 1200, 1800, or 3600 RPM 3 phase, 60 Hz; 230/460 volt operation under 25 HP, 460 volt 25HP and above; 200 & 575 volt available Class F insulation, Class B temperature rise NEMA design B, continuous duty 143T through 449T frame Features for Long Life Frame and End Shields Cast iron frame and end shields for exceptional structural integrity, with sintered condensation / breather drains on 404T 449T frames. Lifting eyebolts are included for motors > 75 lbs. Rotor A unique rotor design provides improved efficiency while larger bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel (C1045) shaft for maximum rotor performance. Specifications table begins on the next page Stator/Windings Manufactured with premium electrical grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross section reduces resistance and lowers stator losses. Insulation Proprietary Class F non-hygroscopic insulation system with NEMA Class B temperature rise, provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical surges. Two seriesconnected normally closed Class B thermostats are supplied as standard. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves airflow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes. Bearings Regreasable, oversized single shielded bearings with cast iron inner caps. Alemite grease fittings on the inlets, and pipe plugs on the relief ports for ease of routine maintenance. Frames 143T 256T are equipped with a shaft seal on the drive end; 284T 449T frames have a drive end V-ring slinger for added bearing life. Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. High Efficiency Oversized Conduit Box Cast iron construction that is larger than industry standards, diagonally-split and rotatable in 90º increments for quick and easy connections. A ground lug is included. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, zinc-plated hardware, epoxy enamel paint and stainless steel nameplate resist rust and corrosion. Modifiable & Cutsom All Siemens motors are available with a wide variety of modifications and custom designs to meet your specific motor needs. Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 4-1 Dimensions

116 Introduction General Purpose Duty Duty Purpose Dimensions Duty - TEFC RGZZESD - Class I, Group D, Class II, Groups F & G, Division 1 HP RPM Frame Voltage Type Horizontal, Foot Mounted DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) T 230/460 RGZZESD Ball 1MB29211AB216AG3 534 SA-7XXP T 575 RGZZESD Ball 1MB29211AB213AG3 534 SA-7XXP T 230/460 RGZZESD Ball 1MB29211AC316AG3 623 SA-7XXP T 575 RGZZESD Ball 1MB29211AC313AG3 623 SA-7XXP T 230/460 RGZZESD Ball 1MB29211CD116AG SA-7XXP T 575 RGZZESD Ball 1MB29211CD113AG SA-7XXP T 230/460 RGZZESD Ball 1MB29211AA216AG3 560 SA-7XXP T 575 RGZZESD Ball 1MB29211AA213AG3 560 SA-7XXP T 230/460 RGZZESD Ball 1MB29211AB316AG3 575 SA-7XXP T 575 RGZZESD Ball 1MB29211AB313AG3 575 SA-7XXP T 230/460 RGZZESD Ball 1MB29211CC116AG3 682 SA-7XXP T 575 RGZZESD Ball 1MB29211CC113AG3 682 SA-7XXP T 230/460 RGZZESD Ball 1MB29211CD316AG SA-7XXP T 575 RGZZESD Ball 1MB29211CD313AG SA-7XXP T 230/460 RGZZESD Ball 1MB29211AA316AG3 638 SA-7XXP T 575 RGZZESD Ball 1MB29211AA313AG3 638 SA-7XXP T 230/460 RGZZESD Ball 1MB29211AB416AG3 616 SA-7XXP T 575 RGZZESD Ball 1MB29211AB413AG3 616 SA-7XXP T 230/460 RGZZESD Ball 1MB29211CC316AG3 772 SA-7XXP T 575 RGZZESD Ball 1MB29211CC313AG3 772 SA-7XXP T 230/460 RGZZESD Ball 1MB29212AD116AG SA-7XXP T 575 RGZZESD Ball 1MB29212AD113AG SA-7XXP T 230/460 RGZZESD Ball 1MB29211CA116AG3 698 SA-7XXP T 575 RGZZESD Ball 1MB29211CA113AG3 698 SA-7XXP T 230/460 RGZZESD Ball 1MB29211CB116AG3 695 SA-7XXP T 575 RGZZESD Ball 1MB29211CB113AG3 695 SA-7XXP T 230/460 RGZZESD Ball 1MB29212AC116AG3 942 SA-7XXP T 575 RGZZESD Ball 1MB29212AC113AG3 942 SA-7XXP T 230/460 RGZZESD Ball 1MB29212AD216AG SA-7XXP T 575 RGZZESD Ball 1MB29212AD213AG SA-7XXP T 230/460 RGZZESD Ball 1MB29211CA316AG3 854 SA-7XXP T 575 RGZZESD Ball 1MB29211CA313AG3 854 SA-7XXP T 230/460 RGZZESD Ball 1MB29211CB316AG3 779 SA-7XXP T 575 RGZZESD Ball 1MB29211CB313AG3 779 SA-7XXP T 230/460 RGZZESD Ball 1MB29212AC216AG SA-7XXP T 575 RGZZESD Ball 1MB29212AC213AG SA-7XXP T 230/460 RGZZESD Ball 1MB29212BD116AG SA-7XXP T 575 RGZZESD Ball 1MB29212BD113AG SA-7XXP Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Stock Model Low Voltage AC Selection and Pricing Guide

117 Duty - TEFC RGZZESD - Class I, Group D, Class II, Groups F & G, Division 1 HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) T 230/460 RGZZESD Ball 1MB29212AA116AG SA-7XXP T 575 RGZZESD Ball 1MB29212AA113AG SA-7XXP T 230/460 RGZZESD Ball 1MB29212AB116AG SA-7XXP T 575 RGZZESD Ball 1MB29212AB113AG SA-7XXP T 230/460 RGZZESD Ball 1MB29212BC116AG SA-7XXP T 575 RGZZESD Ball 1MB29212BC113AG SA-7XXP T 230/460 RGZZESD Ball 1MB29212BD216AG SA-7XXP T 575 RGZZESD Ball 1MB29212BD213AG SA-7XXP T 230/460 RGZZESD Ball 1MB29212AA216AG SA-7XXP T 575 RGZZESD Ball 1MB29212AA213AG SA-7XXP T 230/460 RGZZESD Ball 1MB29212AB216AG SA-7XXP T 575 RGZZESD Ball 1MB29212AB213AG SA-7XXP T 230/460 RGZZESD Ball 1MB29212BC216AG SA-7XXP T 575 RGZZESD Ball 1MB29212BC213AG SA-7XXP T 230/460 RGZZESD Ball 1MB29212CD116AG SA-7XXP T 575 RGZZESD Ball 1MB29212CD113AG SA-7XXP T 230/460 RGZZESD Ball 1MB29212BA116AG SA-7XXP T 575 RGZZESD Ball 1MB29212BA113AG SA-7XXP T 230/460 RGZZESD Ball 1MB29212BB116AG SA-7XXP T 575 RGZZESD Ball 1MB29212BB113AG SA-7XXP T 230/460 RGZZESD Ball 1MB29212CC116AG SA-7XXP T 575 RGZZESD Ball 1MB29212CC113AG SA-7XXP T 230/460 RGZZESD Ball 1MB29212CD216AG SA-7XXP T 575 RGZZESD Ball 1MB29212CD213AG SA-7XXP T 230/460 RGZZESD Ball 1MB29212BA216AG SA-7XXP T 575 RGZZESD Ball 1MB29212BA213AG SA-7XXP T 230/460 RGZZESD Ball 1MB29212BB216AG SA-7XXP T 575 RGZZESD Ball 1MB29212BB213AG SA-7XXP T 230/460 RGZZESD Ball 1MB29212CC216AG SA-7XXP T 575 RGZZESD Ball 1MB29212CC213AG SA-7XXP T 230/460 RGZZESD Ball 1MB29213AD116AG SA-7XXP T 575 RGZZESD Ball 1MB29213AD113AG SA-7XXP TS 460 RGZZESD Ball 1MB29212DA112AG SA-7XXP TS 575 RGZZESD Ball 1MB29212DA113AG SA-7XXP T 460 RGZZESD Ball 1MB29212CB112AG SA-7XXP T 575 RGZZESD Ball 1MB29212CB113AG SA-7XXP T 460 RGZZESD Ball 1MB29213AC112AG SA-7XXP T 575 RGZZESD Ball 1MB29213AC113AG SA-7XXP T 460 RGZZESD Ball 1MB29213AD212AG SA-7XXP T 575 RGZZESD Ball 1MB29213AD213AG SA-7XXP Stock Model Introduction General Purpose Duty Duty Purpose Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Low Voltage AC Selection and Pricing Guide 4-3 Dimensions

118 Introduction General Purpose Duty Duty Purpose Dimensions Duty - TEFC RGZZESD - Class I, Group D, Class II, Groups F & G, Division 1 HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TS 460 RGZZESD Ball 1MB29212DA212AG SA-7XXP TS 575 RGZZESD Ball 1MB29212DA213AG SA-7XXP T 460 RGZZESD Ball 1MB29212CB212AG SA-7XXP T 575 RGZZESD Ball 1MB29212CB213AG SA-7XXP T 460 RGZZESD Ball 1MB29213AC212AG SA-7XXP T 575 RGZZESD Ball 1MB29213AC213AG SA-7XXP T 460 RGZZESD Ball 1MB29213CD112AG SA-7XXP T 575 RGZZESD Ball 1MB29213CD113AG SA-7XXP TS 460 RGZZESD Ball 1MB29213BA112AG SA-7XXP TS 575 RGZZESD Ball 1MB29213BA113AG SA-7XXP T 460 RGZZESD Ball 1MB29213AB112AG SA-7XXP T 575 RGZZESD Ball 1MB29213AB113AG SA-7XXP T 460 RGZZESD Ball 1MB29213CC112AG SA-7XXP T 575 RGZZESD Ball 1MB29213CC113AG SA-7XXP T 460 RGZZESD Ball 1MB29213CD212AG SA-7XXP T 575 RGZZESD Ball 1MB29213CD213AG SA-7XXP TS 460 RGZZESD Ball 1MB29213BA212AG SA-7XXP TS 575 RGZZESD Ball 1MB29213BA213AG SA-7XXP T 460 RGZZESD Ball 1MB29213AB212AG SA-7XXP T 575 RGZZESD Ball 1MB29213AB213AG SA-7XXP T 460 RGZZESD Ball 1MB29213CC212AG SA-7XXP T 575 RGZZESD Ball 1MB29213CC213AG SA-7XXP T 460 RGZZESD Ball 1MB29214AD112AG SA-7XXP T 575 RGZZESD Ball 1MB29214AD113AG SA-7XXP TS 460 RGZZESD Ball 1MB29213DA112AG SA-7XXP TS 575 RGZZESD Ball 1MB29213DA113AG SA-7XXP T 460 RGZZESD Ball 1MB29213CB112AG SA-7XXP T 575 RGZZESD Ball 1MB29213CB113AG SA-7XXP T 460 RGZZESD Ball 1MB29214AC112AG SA-7XXP T 575 RGZZESD Ball 1MB29214AC113AG SA-7XXP T 460 RGZZESD Ball 1MB29214AD212AG SA-7XXP T 575 RGZZESD Ball 1MB29214AD213AG SA-7XXP TS 460 RGZZESD Ball 1MB29213DA212AG SA-7XXP TS 575 RGZZESD Ball 1MB29213DA213AG SA-7XXP T 460 RGZZESD Ball 1MB29213CB212AG SA-7XXP T 575 RGZZESD Ball 1MB29213CB213AG SA-7XXP T 460 RGZZESD Ball 1MB29214AC212AG SA-7XXP T 575 RGZZESD Ball 1MB29214AC213AG SA-7XXP T 460 RGZZESD Roller 1MB29214CD112AG SA-7XXP T 575 RGZZESD Roller 1MB29214CD113AG SA-7XXP Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Stock Model Low Voltage AC Selection and Pricing Guide

119 Duty - TEFC RGZZESD - Class I, Group D, Class II, Groups F & G, Division 1 HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TS 460 RGZZESD Ball 1MB29214BA212AG SA-7XXP TS 575 RGZZESD Ball 1MB29214BA213AG SA-7XXP T 460 RGZZESD Ball 1MB29214AB212AG SA-7XXP T 575 RGZZESD Ball 1MB29214AB213AG SA-7XXP T 460 RGZZESD Roller 1MB29214CC112AG SA-7XXP T 575 RGZZESD Roller 1MB29214CC113AG SA-7XXP T 460 RGZZESD Roller 1MB29214CD212AG SA-7XXP T 575 RGZZESD Roller 1MB29214CD213AG SA-7XXP TS 460 RGZZESD Ball 1MB29214DA112AG SA-7XXP TS 575 RGZZESD Ball 1MB29214DA113AG SA-7XXP TS 460 RGZZESD Ball 1MB29214DB112AG SA-7XXP T 460 RGZZESD Roller 1MB29214CB112AG SA-7XXP B444T 460 RGZZESD Ball 1MB29214EB112AG SA-7XXP TS 575 RGZZESD Ball 1MB29214DB113AG SA-7XXP T 575 RGZZESD Roller 1MB29214CB113AG SA-7XXP T 460 RGZZESD Roller 1MB29214CC212AG SA-7XXP T 575 RGZZESD Roller 1MB29214CC213AG SA-7XXP T 460 RGZZESD Roller 1MB29214CD312AG SA-7XXP T 575 RGZZESD Roller 1MB29214CD313AG SA-7XXP TS 460 RGZZESD Ball 1MB29214DA212AG SA-7XXP TS 575 RGZZESD Ball 1MB29214DA213AG SA-7XXP TS 460 RGZZESD Ball 1MB29214DB212AG SA-7XXP T 460 RGZZESD Roller 1MB29214CB212AG SA-7XXP B445T 460 RGZZESD Ball 1MB29214EB212AG SA-7XXP TS 575 RGZZESD Ball 1MB29214DB213AG SA-7XXP T 575 RGZZESD Roller 1MB29214CB213AG SA-7XXP T 460 RGZZESD Roller 1MB29214CC312AG SA-7XXP T 575 RGZZESD Roller 1MB29214CC313AG SA-7XXP T 460 RGZZESD Roller 1MB29214CD512AG SA-7XXP T 575 RGZZESD Roller 1MB29214CD513AG SA-7XXP TS 460 RGZZESD Ball 1MB29214DA312AG SA-7XXP TS 575 RGZZESD Ball 1MB29214DA313AG SA-7XXP TS 460 RGZZESD Ball 1MB29214DB312AG SA-7XXP T 460 RGZZESD Roller 1MB29214CB312AG SA-7XXP B447T 460 RGZZESD Ball 1MB29214EB312AG SA-7XXP TS 575 RGZZESD Ball 1MB29214DB313AG SA-7XXP T 575 RGZZESD Roller 1MB29214CB313AG SA-7XXP T 460 RGZZESD Roller 1MB29214CC512AG SA-7XXP T 575 RGZZESD Roller 1MB29214CC513AG SA-7XXP B449T 460 RGZZESD Ball 1MB29214EC512AG SA-7XXP T 460 RGZZESD Roller 1MB29214CD612AG SA-7XXP T 575 RGZZESD Roller 1MB29214CD613AG SA-7XXP Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Low Voltage AC Selection and Pricing Guide Stock Model 4-5 Introduction General Purpose Duty Duty Purpose Dimensions

120 Introduction General Purpose Duty Duty Purpose Dimensions Duty - TEFC RGZZESD - Class I, Group D, Class II, Groups F & G, Division 1 HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing Low Voltage AC Selection and Pricing Guide List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TS 460 RGZZESD Ball 1MB29214DA512AG SA-7XXP TS 575 RGZZESD Ball 1MB29214DA513AG SA-7XXP Stock Model T 460 RGZZESD Roller 1MB29214CB512AG SA-7XXP TS 460 RGZZESD Ball 1MB29214DB512AG SA-7XXP TS 575 RGZZESD Ball 1MB29214DB513AG SA-7XXP B449T 460 RGZZESD Ball 1MB29214EB512AG SA-7XXP TS 460 RGZZESD Ball 1MB29214DC612AG SA-7XXP TS 575 RGZZESD Ball 1MB29214DC613AG SA-7XXP TS 460 RGZZESD Ball 1MB29214DA612AG SA-7XXP TS 575 RGZZESD Ball 1MB29214DA613AG SA-7XXP T 460 RGZZESD Roller 1MB29214CB612AG SA-7XXP TS 460 RGZZESD Ball 1MB29214DB612AG SA-7XXP TS 575 RGZZESD Ball 1MB29214DB613AG SA-7XXP C-Face, Vertical with Drip Cover, Footless TCV 230/460 RGZZESD Ball 1MB29211AB216LG3 697 SA-7XXP TCV 230/460 RGZZESD Ball 1MB29211AC316LG3 785 SA-7XXP TCV 230/460 RGZZESD Ball 1MB29211CD116LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29211AA216LG3 722 SA-7XXP TCV 230/460 RGZZESD Ball 1MB29211AB316LG3 737 SA-7XXP TCV 230/460 RGZZESD Ball 1MB29211CC116LG3 845 SA-7XXP TCV 230/460 RGZZESD Ball 1MB29211CD316LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29211AA316LG3 800 SA-7XXP TCV 230/460 RGZZESD Ball 1MB29211AB416LG3 778 SA-7XXP TCV 230/460 RGZZESD Ball 1MB29211CC316LG3 934 SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212AD116LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29211CA116LG3 860 SA-7XXP TCV 230/460 RGZZESD Ball 1MB29211CB116LG3 857 SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212AC116LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212AD216LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29211CA316LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29211CB316LG3 941 SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212AC216LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212BD116LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212AA116LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212AB116LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212BC116LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212BD216LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212AA216LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212AB216LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212BC216LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212BA116LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212BB116LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212CC116LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212BA216LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212BB216LG SA-7XXP TCV 230/460 RGZZESD Ball 1MB29212CC216LG SA-7XXP

121 Duty - TEFC RGZZESD ID1 - Class I, Group D, Division 1 - T2A, 1.15SF RGZZESD ID1 high efficiency explosionproof motors are designed to meet demanding standards of performance and provide long life under oil field operating conditions. They are UL listed and CSA certified for Class I, Division 1, Group D and Class I, Zone 1, Group IIA hazardous locations and meet the requirements of IP54 for enclosure protection. Specifications 1 to 300 HP ºC ambient, ºC ambient (143T 447T), ºC ambient 3600, 1800, 1200 or 900 RPM 3-phase, 60 Hz; 230/460 volt operation under 100 HP, 460 volt 100 HP and above, 575 volt available Meets or exceeds EPAct efficiency standards Class F insulation, Class B temperature rise NEMA design B, continuous duty 284T through 449T frame T2A temperature code (280ºC maximum surface temperature) 3600, 1800 or 1200 RPM 3 phase, 60 Hz; 230/460 volt operation under 25 HP, 460 volt 25 HP and above; 200 & 575 volt available Class F insulation, Class B temperature rise NEMA design B, continuous duty 143T through 449T frame Features for Long Life Frame and Bearing Housings Cast iron frame and end shields for exceptional structural integrity, with sintered condensation drains on 404T 449T frames. Lifting eyebolts are included for frames 213T to 449T. Specifications table begins on the next page Rotor A unique rotor design provides improved efficiency while larger bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel (C1045) shaft for maximum rotor performance. Stator/Windings Manufactured with premium electrical grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross section reduces resistance and lowers stator losses. Insulation Proprietary Class F non-hygroscopic insulation system with NEMA Class B temperature rise, provides an extra margin of thermal life. Varnish system application insures maximum wire penetration to provide protection from moisture and corrosion. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves airflow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes. Bearings Regreasable, oversized single shielded bearings with cast iron inner caps. Alemite grease fittings on the inlets, and pipe plugs on the relief ports for ease of routine maintenance. Frames 143T 256T are equipped with a shaft seal on the drive end; 284T 449T frames have a drive end V-ring slinger for added bearing life. Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. High Efficiency Oversized Conduit Box Cast iron, explosion proof construction, that is larger than industry standards, for quick and easy connections. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, zinc-plated hardware, epoxy enamel paint and stainless steel nameplate resist rust and corrosion. Modifiable & All Siemens motors are available with a wide variety of QuickMOD modifications and custom designs to meet your specific motor needs. Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 4-7 Dimensions

122 Introduction General Purpose Duty Duty Purpose Dimensions Duty - TEFC RGZZESD ID1 - Class I, Group D, Division 1 - T2A, 1.15SF HP RPM Frame Voltage Type Horizontal, Foot Mounted DE Bearing Low Voltage AC Selection and Pricing Guide List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) T 230/460 RGZZESD ID1 Ball 1MB29111AB216AA3 524 SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29111AC316AA3 611 SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29111AA216AA3 549 SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29111AB316AA3 564 SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29111CC116AA3 669 SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29111AA316AA3 625 SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29111AB416AA3 604 SA-7XXP % T 575 RGZZESD ID1 Ball 1MB29111AB413AA3 604 SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29111CC316AA3 757 SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29111CA116AA3 684 SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29111CB116AA3 681 SA-7XXP % T 575 RGZZESD ID1 Ball 1MB29111CB113AA3 681 SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112AC116AA3 924 SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29111CA316AA3 837 SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29111CB316AA3 764 SA-7XXP % T 575 RGZZESD ID1 Ball 1MB29111CB313AA3 764 SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112AC216AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112AA116AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112AB116AA SA-7XXP % T 575 RGZZESD ID1 Ball 1MB29112AB113AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112BC116AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112AA216AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112AB216AA SA-7XXP % T 575 RGZZESD ID1 Ball 1MB29112AB213AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112BC216AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112BA116AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112BB116AA SA-7XXP % T 575 RGZZESD ID1 Ball 1MB29112BB113AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112CC116AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112BA216AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112BB216AA SA-7XXP % T 575 RGZZESD ID1 Ball 1MB29112BB213AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112CC216AA SA-7XXP % 525 Stock Model TS 230/460 RGZZESD ID1 Ball 1MB29112DA116AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112CB116AA SA-7XXP % T 575 RGZZESD ID1 Ball 1MB29112CB113AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29113AC116AA SA-7XXP % TS 230/460 RGZZESD ID1 Ball 1MB29112DA216AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29112CB216AA SA-7XXP % T 575 RGZZESD ID1 Ball 1MB29112CB213AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29113AC216AA SA-7XXP % TS 230/460 RGZZESD ID1 Ball 1MB29113BA116AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29113AB116AA SA-7XXP % T 575 RGZZESD ID1 Ball 1MB29113AB113AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29113CC116AA SA-7XXP % 900

123 Duty - TEFC RGZZESD ID1 - Class I, Group D, Division 1 - T2A, 1.15SF HP RPM Frame Voltage Type Horizontal, Foot Mounted - continued DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TS 230/460 RGZZESD ID1 Ball 1MB29113BA216AA SA-7XXP % Low Voltage AC Selection and Pricing Guide Stock Model T 230/460 RGZZESD ID1 Ball 1MB29113AB216AA SA-7XXP % T 575 RGZZESD ID1 Ball 1MB29113AB213AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29113CC216AA SA-7XXP % TS 230/460 RGZZESD ID1 Ball 1MB29113DA116AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29113CB116AA SA-7XXP % T 575 RGZZESD ID1 Ball 1MB29113CB113AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29114AC116AA SA-7XXP % TS 230/460 RGZZESD ID1 Ball 1MB29113DA216AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29113CB216AA SA-7XXP % T 575 RGZZESD ID1 Ball 1MB29113CB213AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29114AC216AA SA-7XXP % TS 230/460 RGZZESD ID1 Ball 1MB29114BA216AA SA-7XXP % T 230/460 RGZZESD ID1 Ball 1MB29114AB216AA SA-7XXP % T 575 RGZZESD ID1 Ball 1MB29114AB213AA SA-7XXP % T 230/460 RGZZESD ID1 Roller 1MB29114CC116AA SA-7XXP % B444T 230/460 RGZZESD ID1 Ball 1MB29114EC116AA SA-7XXP % TS 460 RGZZESD ID1 Ball 1MB29114DA112AA SA-7XXP % T 460 RGZZESD ID1 Roller 1MB29114CB112AA SA-7XXP % B444T 460 RGZZESD ID1 Ball 1MB29114EB112AA SA-7XXP % T 575 RGZZESD ID1 Roller 1MB29114CB113AA SA-7XXP % B444T 575 RGZZESD ID1 Ball 1MB29114EB113AA SA-7XXP % T 460 RGZZESD ID1 Roller 1MB29114CC212AA SA-7XXP % B445T 460 RGZZESD ID1 Ball 1MB29114EC212AA SA-7XXP % TS 460 RGZZESD ID1 Ball 1MB29114DA212AA SA-7XXP % T 460 RGZZESD ID1 Roller 1MB29114CB212AA SA-7XXP % B445T 460 RGZZESD ID1 Ball 1MB29114EB212AA SA-7XXP % T 575 RGZZESD ID1 Roller 1MB29114CB213AA SA-7XXP % B445T 575 RGZZESD ID1 Ball 1MB29114EB213AA SA-7XXP % T 460 RGZZESD ID1 Roller 1MB29114CC312AA SA-7XXP % B447T 460 RGZZESD ID1 Ball 1MB29114EC312AA SA-7XXP % TS 460 RGZZESD ID1 Ball 1MB29114DA312AA SA-7XXP % T 460 RGZZESD ID1 Roller 1MB29114CB312AA SA-7XXP % B447T 460 RGZZESD ID1 Ball 1MB29114EB312AA SA-7XXP % T 460 RGZZESD ID1 Roller 1MB29114CC512AA SA-7XXP % B449T 460 RGZZESD ID1 Ball 1MB29114EC512AA SA-7XXP % TS 460 RGZZESD ID1 Ball 1MB29114DA512AA SA-7XXP % T 460 RGZZESD ID1 Roller 1MB29114CB512AA SA-7XXP % B449T 460 RGZZESD ID1 Ball 1MB29114EB512AA SA-7XXP % TS 460 RGZZESD ID1 Ball 1MB29114DA612AA SA-7XXP % T 460 RGZZESD ID1 Roller 1MB29114CB612AA SA-7XXP % B449T 460 RGZZESD ID1 Ball 1MB29114EB612AA SA-7XXP % 2625 Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V 4-9 Introduction General Purpose Duty Duty Purpose Dimensions

124 Duty - TEFC RGZZESD ID1 - Class I, Group D, Division 1 - T2A, 1.15SF HP RPM Frame Voltage Type Introduction C-Face, Vertical with Drip Cover, Footless DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) TCV 230/460 RGZZESD ID1 Ball 1MB29111AB216LA3 683 SA-7XXP % TCV 230/460 RGZZESD ID1 Ball 1MB29111AB316LA3 723 SA-7XXP % TCV 230/460 RGZZESD ID1 Ball 1MB29111AB416LA3 763 SA-7XXP % TCV 230/460 RGZZESD ID1 Ball 1MB29111CB116LA3 840 SA-7XXP % TCV 230/460 RGZZESD ID1 Ball 1MB29111CB316LA3 923 SA-7XXP % TCV 230/460 RGZZESD ID1 Ball 1MB29112AB116LA SA-7XXP % TCV 230/460 RGZZESD ID1 Ball 1MB29112AB216LA SA-7XXP % TCV 230/460 RGZZESD ID1 Ball 1MB29112BB116LA SA-7XXP % TCV 230/460 RGZZESD ID1 Ball 1MB29112BB216LA SA-7XXP % TCV 230/460 RGZZESD ID1 Ball 1MB29112CB116LA SA-7XXP % TCV 230/460 RGZZESD ID1 Ball 1MB29112CB216LA SA-7XXP % 525 Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Stock Model Dimensions General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide

125 Duty (XP ) Type / Frame List Price Adder Per Frame ($) Order Description RGZZESD RGZZESD 1D1 Code Code Pos S449 Altitude / Ambient Rerate/Derate Y80 Z Assembly - Mounting & Terminal Box Position W-2 9+R2A 16+Z W-3 9+R3A 16+Z W C Bearings Sealed Ball bearings 1 L68 Z (except 2 pole, 360+ frames) Breathers & Drain Plugs Crouse Hinds - UL Approved L46 Z Conduit Box - Main Orient 90 deg CCW J84 Z Orient 180 deg CCW J85 Z Orient 270 deg CCW J86 Z Drip Cover Drip cover without vertical K33 Z lifting devices Export Packaging Sea Freight - Siemens B09 Z Standard Flanged End Shields C-Face with Feet 2 E C-Face without Feet G Grounding Provision (tapped hole on L27 Z frame w/bolt) Hardware Lifting Eyebolt 3 L20 Z std std std std std std std std std std Duty Group D, F&G, 1.15SF M80 Z (Rerate) Insulation Fungus Protection C07 Z Leads / Terminal Blocks Burndy Hydent type YA K80 Z Sealed Leads K89 Z std std std std std std std std std std std std std Lubrication Grease Fitting / Pressure Relief L60 Z Nameplate Extra M21 Z Division 2 4 M22 Z Change (Rerate/Derate) Y80 Z Auxiliary Y82 Z For further details please refer to section 8 1 Sealed Ball not available for 2 pole motors with frames > C face with fee for 440 frames, only available with ball bearings 3 Lisfting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required Low Voltage AC Selection and Pricing Guide 4-11 Introduction General Purpose Duty Duty Purpose Dimensions

126 Introduction General Purpose Duty Duty Purpose Duty (XP ) Description Code Order Code Pos Type / Frame List Price Adder Per Frame ($) RGZZESD RGZZESD 1D Protective Devices - Windings Thermostats, normally G 15 std - std std std std std std std std std std std closed, 2 per motor Rotation Arrow Bidirectional (not applicable K70 Z for uni-directional motors) Clockwise (facing ODE) K71 Z Counterclockwise (facing K72 Z ODE) Service Factor Rerate/Derate Y80 Z Shaft Seal Slinger & O Ring L76 Z (4, 6, 8 Pole only) Software Documentation in Spanish D05 Z Certificate of Compliance F00 Z Standard Transmittal F40 Z Standard Dimension Sheet F42 Z Conduit Box Dimension Sheet F44 Z Wiring Diagram F45 Z IOM F46 Z Renewal Parts F47 Z Sheets F49 Z F03 Z Testing Routine Test Report F10 Z Routine Test Report with Vibration Test F20 Z Voltage Single Voltage - 230V (outside leads connection only) Single Voltage - 460V (outside leads connection only) & &13 For further details please refer to section 8 1 Sealed Ball not available for 2 pole motors with frames > C face with fee for 440 frames, only available with ball bearings 3 Lisfting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required. 20HP HP S449 Dimensions Low Voltage AC Selection and Pricing Guide

127 Options Duty (XP ) Description Type / Frame List Price Adder Per Frame ($) Order RGZZESD RGZZESD S449 Code Code 1D Pos Assembly - Mounting & Terminal Box Position W W F Auxiliary boxes 1 Auxiliary conduit box location (Digit 2) XP condulet opposite to main box J 6 Z Temperature detector device (Digit 1) Select the number that corresponds with the appropriate Temperature Detector Device to create your initial 3 digital ordering code. Thermostats 1 Space heaters 5 Balance Precision M69 Z Extra Precision M70 Z Bearings Roller Instead of Ball L65 Z std std std Couplings er Supplied H10 Z Export Packaging Special B10 Z cf cf cf cf cf cf cf cf cf cf cf Fans Bronze M10 Z Duty Group C&D, 1.15SF M81 Z Group C&D, F&G, 1.0SF M82 Z Only Insulation Class H C00 Z Vacuum Pressure Impregnation (VPI) C01 Z Moisture/Powerhouse C04 Z (extra dip & bake) Tropicalization Moisture C08 Z (extra dip & bake, fungus spray) Lubrication Special Grease (High & L57 Z Low Temp) (Mobil 28) Special Grease (Mobilith SHC 100) L58 Z For further details please refer to section 9 For availability for Flanges and End shields as Options see page 9-14 Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 4-13 Dimensions

128 Introduction General Purpose Duty Duty Purpose Options Duty (XP ) Description Order Code Code Pos Type / Frame List Price Adder Per Frame ($) RGZZESD RGZZESD D Paint Paint - 3 Part Epoxy N01 Z (Carboline or Ameron) Paint - 2 Part Epoxy N02 Z Standard Primer Only N03 Z Standard Paint, Special Y60 Z Color Special Paint, Special Color Y61 Z cf cf cf cf cf cf cf cf cf cf cf Protective Devices - Windings PTC thermistors, 3 B embedded temperature sensors for tripping PTC thermistors, 6 C embedded temperature sensors for alarm and tripping KTY84-130, 2 F embedded temperature sensors Thermocouples, coil J head Winding temperature K protection, Stator RTD's (coil head, 1 per phase), 100Ω Platinum, complete with auxiliary box with terminal strip opposite to main box Shafts Carbon Steel (C4140) M57 Z Shaft DE Special to Y50 Z cf cf cf cf cf cf cf cf cf cf cf er Specifications Shaft ODE Special to Y51 Z cf cf cf cf cf cf cf cf cf cf cf er Specifications NEMA Standard Short M53 Z Shaft - ODE NEMA Standard Long Shaft - ODE M52 Z For further details please refer to section 9 S449 Dimensions Low Voltage AC Selection and Pricing Guide

129 Options Duty (XP ) Description Order Code Code Pos Type / Frame List Price Adder Per Frame ($) RGZZESD RGZZESD D Shaft Seal Brass Seal L84 Z Software Nonstandard Dimension F43 Z Sheet er Specific F50 Z Sheets Special Calculated F07 Z Space Heater 115V, Single Phase, Ex. A43 Z Proof Testing Routine Test Report - F12 Z (Witnessed) Complete Test F15 Z Complete Test (Witnessed) F17 Z Calibration Test F27 Z Electrical Duplicate - F36 Z (Routine Test) Electrical Duplicate (Complete Test) F37 Z Noise F30 Z Noise (Witnessed) F32 Z Routine Test Report F22 Z with Vibration Test (Witnessed) Vertical Jacking Vertical Jacking M39 Z Provision Vibration Detectors Vibraswitch Robert Shaw malfunction detector Model D8 120VAC A66 Z For further details please refer to section 9 S449 Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 4-15 Dimensions

130 Introduction General Purpose Duty Options Duty (XP ) Description Voltage Special Voltage V Special Voltage V Part Winding Start - 200V, 60Hz Part Winding Start - 230V, 60Hz Part Winding Start - 460V, 60Hz Part Winding Start - 575V, 60Hz Wye Start - Delta Run - 200V, 60Hz Wye Start - Delta Run - 230V, 60Hz Wye Start - Delta Run - 460V, 60Hz Wye Start - Delta Run - 575V, 60Hz Order Code Code Pos , M1Y 13+Z , M2Y 13+Z & & & & & & & &13 For further details please refer to section 9 Type / Frame List Price Adder Per Frame ($) RGZZESD RGZZESD D S449 Dimensions Duty Purpose Low Voltage AC Selection and Pricing Guide

131 Duty - TEFC RGZESDI - 10:1 Constant Torque RGZESDI inverter duty high efficiency severe duty TEFC motors are designed for inverter or vector applications where up to a 10:1 constant torque speed range is required. These motors are well suited to be used in adjustable speed applications such as mixers, chemical processing, pulp and paper, waste management and petro/chemical. Specifications 1 to 350 HP 1.15 service factor on sine wave power, 40ºC ambient 1.0 service factor on inverter power 3600, 1800, 1200 or 900 RPM 3 phase, 60 Hz, 460 volt; 200, 230 & 575 volt available Meets or exceeds EPAct Efficiency standards Class F insulation, Class B temperature rise Continuous Duty 143T through S449 frame Features for Long Life Frame & Bearing Housings Cast iron construction for exceptional structural integrity and corrosion resistance. Condensation T-drains provided. Lifting eyebolts are included for motors > 75 lbs. Rotor A unique rotor design provides improved efficiency while larger bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel (C1045) shaft for maximum rotor performance. Specifications table begins on the next page Stator/Windings Manufactured with premium electrical grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross section reduces resistance, also lowering stator losses. Insulation Proprietary inverter duty Class F non-hygroscopic (corona resistant) insulation system with NEMA Class B temperature rise provides an extra margin of thermal life. All motors are equipped with two series connected, normally closed, Class F thermostats for detection of overload conditions and/or excessive heating. Suitable for operation from adjustable speed drives with an insulation system that meets or exceeds NEMA MG1-2006, Part 31. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves airflow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes. Bearings Regreasable, oversized single shielded with cast iron inner caps. Alemite grease fittings on the inlets and pipe plugs on the relief ports for ease of routine maintenance. For added bearing protection, 143T-256T frames have a drive end shaft seal and 284T-S449 frames have a drive end shaft V-ring slinger. Lubrication A specially formulated, high temperature tested, polyurea based grease is used to provide more than four times the lubrication life of other polyurea greases. High Efficiency Oversized Conduit Box Cast iron construction that is larger than industry standards, diagonally-split, neoprene gasketed and rotatable in 90º increments for quick and easy connections. A ground lug is provided. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, zinc-plated hardware, epoxy enamel paint and stainless steel nameplate resist rust and corrosion. Modifiable & All Siemens motors are available with a wide variety of modifications and custom designs to meet your specific motor needs. Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 5-1 Dimensions

132 Introduction General Purpose Duty Duty Purpose Dimensions Duty - TEFC RGZESDI - 10:1 Constant Torque HP RPM Frame Voltage Type DE Bearing Low Voltage AC Selection and Pricing Guide List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) T 460 RGZESDI Ball 1PC28911AB212AG3 775 SA-7INV T 460 RGZESDI Ball 1PC28911AC312AG3 855 SA-7INV T 460 RGZESDI Ball 1PC28911CD112AG SA-7INV T 460 RGZESDI Ball 1PC28911AA212AG3 875 SA-7INV T 460 RGZESDI Ball 1PC28911AB312AG3 805 SA-7INV T 460 RGZESDI Ball 1PC28911CC112AG SA-7INV T 460 RGZESDI Ball 1PC28911CD312AG SA-7INV T 460 RGZESDI Ball 1PC28911AA312AG3 910 SA-7INV T 460 RGZESDI Ball 1PC28911AB412AG3 840 SA-7INV T 460 RGZESDI Ball 1PC28911CC312AG SA-7INV T 460 RGZESDI Ball 1PC28912AD112AG SA-7INV T 460 RGZESDI Ball 1PC28911CA112AG SA-7INV T 460 RGZESDI Ball 1PC28911CB112AG3 985 SA-7INV T 460 RGZESDI Ball 1PC28912AC112AG SA-7INV T 460 RGZESDI Ball 1PC28912AD212AG SA-7INV T 460 RGZESDI Ball 1PC28911CA312AG SA-7INV T 460 RGZESDI Ball 1PC28911CB312AG SA-7INV T 460 RGZESDI Ball 1PC28912AC212AG SA-7INV T 460 RGZESDI Ball 1PC28912BD012AG SA-7INV T 460 RGZESDI Ball 1PC28912AA112AG SA-7INV T 460 RGZESDI Ball 1PC28912AB112AG SA-7INV T 460 RGZESDI Ball 1PC28912BC012AG SA-7INV T 460 RGZESDI Ball 1PC28912CD712AG SA-7INV T 460 RGZESDI Ball 1PC28912AA212AG SA-7INV T 460 RGZESDI Ball 1PC28912AB212AG SA-7INV T 460 RGZESDI Ball 1PC28912CC712AG SA-7INV T 460 RGZESDI Ball 1PC28912CD812AG SA-7INV T 460 RGZESDI Ball 1PC28912BA012AG SA-7INV T 460 RGZESDI Ball 1PC28912BB012AG SA-7INV T 460 RGZESDI Ball 1PC28912CC812AG SA-7INV T 460 RGZESDI Ball 1PC28913BD712AG SA-7INV TS 460 RGZESDI Ball 1PC28912DA512AG SA-7INV T 460 RGZESDI Ball 1PC28912CB712AG SA-7INV T 460 RGZESDI Ball 1PC28913BC712AG SA-7INV T 460 RGZESDI Ball 1PC28913AD012AG SA-7INV TS 460 RGZESDI Ball 1PC28912DA612AG SA-7INV T 460 RGZESDI Ball 1PC28912CB812AG SA-7INV T 460 RGZESDI Ball 1PC28913AC012AG SA-7INV T 460 RGZESDI Ball 1PC28913DD712AG SA-7INV TS 460 RGZESDI Ball 1PC28913BA512AG SA-7INV T 460 RGZESDI Ball 1PC28913BB712AG SA-7INV T 460 RGZESDI Ball 1PC28913DC712AG SA-7INV T 460 RGZESDI Ball 1PC28913CD012AG SA-7INV TS 460 RGZESDI Ball 1PC28913BA612AG SA-7INV T 460 RGZESDI Ball 1PC28913AB012AG SA-7INV T 460 RGZESDI Ball 1PC28913CC012AG SA-7INV T 460 RGZESDI Ball 1PC28914AD712AG SA-7INV Stock Model

133 Duty - TEFC RGZESDI - 10:1 Constant Torque HP RPM Frame Voltage Type DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) TS 460 RGZESDI Ball 1PC28913DA512AG SA-7INV T 460 RGZESDI Ball 1PC28913DB712AG SA-7INV T 460 RGZESDI Ball 1PC28914AC712AG SA-7INV T 460 RGZESDI Ball 1PC28914BD612AG SA-7INV TS 460 RGZESDI Ball 1PC28913DA612AG SA-7INV T 460 RGZESDI Ball 1PC28913CB012AG SA-7INV T 460 RGZESDI Ball 1PC28914BC612AG SA-7INV TS 460 RGZESDI Ball 1PC28914PD112AG SA-7INV TS 460 RGZESDI Ball 1PC28914BA512AG SA-7INV T 460 RGZESDI Ball 1PC28914BB612AG SA-7INV TS 460 RGZESDI Ball 1PC28914PC112AG SA-7INV TS 460 RGZESDI Ball 1PC28914PD212AG SA-7INV TS 460 RGZESDI Ball 1PC28914PA112AG SA-7INV TS 460 RGZESDI Ball 1PC28914PB112AG SA-7INV TS 460 RGZESDI Ball 1PC28914PC212AG SA-7INV TS 460 RGZESDI Ball 1PC28914PD312AG SA-7INV TS 460 RGZESDI Ball 1PC28914PA212AG SA-7INV TS 460 RGZESDI Ball 1PC28914PB212AG SA-7INV TS 460 RGZESDI Ball 1PC28914PC312AG SA-7INV TS 460 RGZESDI Ball 1PC28914DD812AG SA-7INV TS 460 RGZESDI Ball 1PC28914PA312AG SA-7INV TS 460 RGZESDI Ball 1PC28914PB312AG SA-7INV TS 460 RGZESDI Ball 1PC28914PC412AG SA-7INV TS 460 RGZESDI Ball 1PC28914PD512AG SA-7INV TS 460 RGZESDI Ball 1PC28914PA412AG SA-7INV TS 460 RGZESDI Ball 1PC28914PB412AG SA-7INV TS 460 RGZESDI Ball 1PC28914PC512AG SA-7INV TS 460 RGZESDI Ball 1PC28914PA512AG SA-7INV TS 460 RGZESDI Ball 1PC28914PB512AG SA-7INV S449SS 460 RGZESDI Ball 1PC28914GC212AG SA-7INV S449SS 460 RGZESDI Ball 1PC28914GA212AG SA-7INV S449SS 460 RGZESDI Ball 1PC28914GB112AG SA-7INV S449SS 460 RGZESDI Ball 1PC28914GA112AG SA-7INV S449SS 460 RGZESDI Ball 1PC28914GB212AG SA-7INV Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V Weight (lbs) Stock Model Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 5-3 Dimensions

134 Introduction General Purpose Duty Duty Duty - TEFC & TEBC RGKESDI & RGZESDI :1 Constant Torque RGZESDI inverter duty high efficiency severe duty TEFC & TEBC (blower cooled) motors are designed for inverter or vector applications where up to a 1000:1 constant torque speed range is required. These motors are well suited to be used in adjustable speed applications such as mixers, chemical processing, pulp and paper and petro/chemical. Specifications 1 to 400 HP 1.15 service factor on sine wave power, 40ºC ambient 1.0 service factor on inverter power 3600, 1800, 1200 or 900 RPM 3 phase, 60 Hz, 460 volt; 200, 230 & 575 volt available Meets or exceeds EPAct Efficiency standards Class F insulation, Class B temperature rise Continuous Duty 143T through S449 frame Features for Long Life Frame & Bearing Housings Cast iron construction for exceptional structural integrity and corrosion protection. Condensation T-drains provided. Lifting eyebolts are included for motors > 75 lbs. Rotor A unique rotor design provides improved efficiency while larger bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel (C1045) shaft for maximum rotor performance. Specifications table begins on the next page Stator/Windings Manufactured with premium electrical grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross section reduces resistance, also lowering stator losses. Insulation Proprietary inverterduty Class F non-hygroscopic (corona resistant) insulation system with NEMA Class B temperature rise provides an extra margin of thermal life. All motors are equipped with two series connected, normally closed, Class F thermostats for detection of overload conditions and/or excessive heating. Suitable for operation from adjustable speed drives with an insulation system that meets or exceeds NEMA MG1-2006, Part 31. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves airflow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes. Bearings Regreasable, oversized single shielded with cast iron inner caps. Alemite grease fittings on the inlets and pipe plugs on the relief ports for ease of routine maintenance. For added bearing protection, 143T-256T frames have a drive end shaft seal and 284T-S449 frames have a drive end shaft V-ring slinger. Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. High Efficiency Oversized Conduit Box Cast iron construction that is larger than industry standards, diagonally-split, neoprene gasketed and rotatable in 90º increments for quick and easy connections. A ground lug is provided. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, zinc-plated hardware, epoxy enamel paint and stainless steel nameplate resist rust and corrosion. Modifiable & All Siemens motors are available with a wide variety of modifications and custom designs to meet your specific motor needs. Dimensions Purpose Low Voltage AC Selection and Pricing Guide

135 Duty - TEFC & TEBC RGKESDI & RGZESDI :1 Constant Torque HP RPM Frame Voltage Type DE Bearing Enclosure List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) T 460 RGKESDI Ball TEFC 1PC29111AB512AG3 805 SA-7INV T 460 RGKESDI Ball TEFC 1PC29111CC612AG SA-7INV T 460 RGKESDI Ball TEFC 1PC29111CA612AG SA-7INV T 460 RGKESDI Ball TEFC 1PC29111CB612AG3 895 SA-7INV T 460 RGKESDI Ball TEFC 1PC29111CC712AG SA-7INV T 460 RGKESDI Ball TEFC 1PC29111CA812AG SA-7INV T 460 RGKESDI Ball TEFC 1PC29111CB512AG3 985 SA-7INV T 460 RGKESDI Ball TEFC 1PC29112KC512AG SA-7INV T 460 RGKESDI Ball TEFC 1PC29112KA112AG SA-7INV T 460 RGKESDI Ball TEFC 1PC29111CB712AG SA-7INV T 460 RGKESDI Ball TEFC 1PC29112AC012AG SA-7INV T 460 RGKESDI Ball TEFC 1PC29112KA212AG SA-7INV T 460 RGKESDI Ball TEFC 1PC29112KB512AG SA-7INV T 460 RGKESDI Ball TEFC 1PC29112KC612AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29212BD112AG SA-7INV T 460 RGKESDI Ball TEFC 1PC29112KA312AG SA-7INV T 460 RGKESDI Ball TEFC 1PC29112BB712AG SA-7INV T 460 RGKESDI Ball TEFC 1PC29112BC012AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29212BD212AG SA-7INV T 460 RGKESDI Ball TEFC 1PC29112KA412AG SA-7INV T 460 RGKESDI Ball TEFC 1PC29112BB812AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29212BC212AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29212CD112AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29212BA112AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29212BB112AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29212CC112AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29212CD212AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29212BA212AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29212BB212AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29212CC212AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29213AD112AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29212DA112AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29212CB112AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29213AC112AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29213AD212AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29212DA212AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29212CB212AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29213AC212AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29213CD112AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29213BA112AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29213AB112AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29213CC112AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29213CD212AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29213BA212AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29213AB212AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29213CC212AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29214AD112AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29213DA112AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29213CB112AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29214AC112AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29214AD212AG SA-7INV Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V Low Voltage AC Selection and Pricing Guide Stock Model 5-5 Introduction General Purpose Duty Duty Purpose Dimensions

136 Duty - TEFC & TEBC RGKESDI & RGZESDI :1 Constant Torque Introduction HP RPM Frame Voltage Type DE Bearing Enclosure List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) TS 460 RGZESDI Ball TEBC 1PC29213DA212AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29213CB212AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29214AC212AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DD112AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214BA212AG SA-7INV T 460 RGZESDI Ball TEBC 1PC29214AB212AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DC112AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DD212AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DA112AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DB112AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DC212AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DD312AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DA212AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DB212AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DC312AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DD412AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DA312AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DB312AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DC512AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DD612AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DA512AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DB512AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DC612AG SA-7INV S449SS 460 RGZESDI Ball TEBC 1PC29214GD212AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DA612AG SA-7INV TS 460 RGZESDI Ball TEBC 1PC29214DB612AG SA-7INV S449SS 460 RGZESDI Ball TEBC 1PC29214GC112AG SA-7INV S449SS 460 RGZESDI Ball TEBC 1PC29214GA112AG SA-7INV S449SS 460 RGZESDI Ball TEBC 1PC29214GB212AG SA-7INV S449SS 460 RGZESDI Ball TEBC 1PC29214GC312AG SA-7INV S449SS 460 RGZESDI Ball TEBC 1PC29214GA312AG SA-7INV S449SS 460 RGZESDI Ball TEBC 1PC29214GB312AG SA-7INV Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V Weight (lbs) Stock Model Dimensions General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide

137 Duty - TEFC RGZZESDI - Class I, Group D, Class II, Groups F & G, Division 1 RGZZESDI high efficiency explosionproof motors are UL listed for dust ignition proof environments, and are suitable for use in Class I, Group D, Class II, Groups F & G, Division 1 hazardous areas. They are ideal for use in applications such as chemical processing, pulp and paper, waste management, and petro/chemical. Specifications 1 to 200 HP 1.0 service factor, 40ºC ambient T3B temperature code 3600, 1800, 1200, or 900 RPM 3 phase, 60 Hz; 230 or 460 volt operation under 25 HP 460 volt 25 HP and above; 200 & 575 volt available Class F insulation, Class B temperature rise NEMA design B, continuous duty 143T through 449T frame Features for Long Life Frame & Bearing Housings Cast iron frame and end shields for exceptional structural integrity and corrosion resistance. Sintered condensation / breather drains on 404T 449T frames. Lifting eyebolts are included for motors > 75 lbs. Rotor A unique rotor design provides improved efficiency while larger bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel (C1045) shaft for maximum rotor performance. Specifications table begins on the next page Stator/Windings Manufactured with premium electrical grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross section reduces resistance, also lowering stator losses. Insulation Proprietary Class F non-hygroscopic insulation system with NEMA Class B temperature rise provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical surges. Two seriesconnected normally closed Class B thermostats are supplied as standard. Suitable for operation from adjustable speed drives with an insulation system that meets or exceeds NEMA MG1-2006, Part 31. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves airflow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes. Bearings Regreasable, oversized single shielded bearings with cast iron inner caps. Alemite grease fittings on the inlets, and pipe plugs on the relief ports for ease of routine maintenance. Frames 143T 256T are equipped with a shaft seal on the drive end; 284T 449T frames have a drive end V-ring slinger for added bearing life. Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. High Efficiency Oversized Conduit Box Cast iron construction that is larger than industry standards, diagonally-split and rotatable in 90º increments for quick and easy connections. A ground lug is provided. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, zinc-plated hardware, epoxy enamel paint and stainless steel nameplate resist rust and corrosion. Modifiable & All Siemens motors are available with a wide variety of modifications and custom designs to meet your specific motor needs. Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 5-7 Dimensions

138 Introduction General Purpose Duty Duty Purpose Dimensions Duty - TEFC RGZZESDI - Class I, Group D, Class II, Groups F & G, Division 1 HP RPM Frame Voltage Type DE Bearing Low Voltage AC Selection and Pricing Guide List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) T 460 RGZZESDI Ball 1PC29311AA112AG3 672 SA-7XXP T 460 RGZZESDI Ball 1PC29311AB512AG3 687 SA-7XXP T 460 RGZZESDI Ball 1PC29311CC612AG3 795 SA-7XXP T 460 RGZZESDI Ball 1PC29311CD712AG SA-7XXP T 460 RGZZESDI Ball 1PC29311AA512AG3 750 SA-7XXP T 460 RGZZESDI Ball 1PC29311AB312AG3 728 SA-7XXP T 460 RGZZESDI Ball 1PC29311CC712AG3 884 SA-7XXP T 460 RGZZESDI Ball 1PC29312KD512AG SA-7XXP T 460 RGZZESDI Ball 1PC29311CA512AG3 810 SA-7XXP T 460 RGZZESDI Ball 1PC29311CB512AG3 807 SA-7XXP T 460 RGZZESDI Ball 1PC29312KC512AG SA-7XXP T 460 RGZZESDI Ball 1PC29312AD012AG SA-7XXP T 460 RGZZESDI Ball 1PC29311CA712AG3 966 SA-7XXP T 460 RGZZESDI Ball 1PC29311CB712AG3 891 SA-7XXP T 460 RGZZESDI Ball 1PC29312AC012AG SA-7XXP T 460 RGZZESDI Ball 1PC29312KD612AG SA-7XXP T 460 RGZZESDI Ball 1PC29312KA512AG SA-7XXP T 460 RGZZESDI Ball 1PC29312KB512AG SA-7XXP T 460 RGZZESDI Ball 1PC29312KC612AG SA-7XXP T 460 RGZZESDI Ball 1PC29312BD012AG SA-7XXP T 460 RGZZESDI Ball 1PC29312AA012AG SA-7XXP T 460 RGZZESDI Ball 1PC29312AB012AG SA-7XXP T 460 RGZZESDI Ball 1PC29312BC012AG SA-7XXP T 460 RGZZESDI Ball 1PC29312CD712AG SA-7XXP T 460 RGZZESDI Ball 1PC29312KA612AG SA-7XXP T 460 RGZZESDI Ball 1PC29312KB612AG SA-7XXP T 460 RGZZESDI Ball 1PC29312CC712AG SA-7XXP T 460 RGZZESDI Ball 1PC29312CD812AG SA-7XXP T 460 RGZZESDI Ball 1PC29312BA012AG SA-7XXP T 460 RGZZESDI Ball 1PC29312BB012AG SA-7XXP T 460 RGZZESDI Ball 1PC29312CC812AG SA-7XXP T 460 RGZZESDI Ball 1PC29313BD712AG SA-7XXP TS 460 RGZZESDI Ball 1PC29312DA512AG SA-7XXP T 460 RGZZESDI Ball 1PC29312CB712AG SA-7XXP T 460 RGZZESDI Ball 1PC29313BC712AG SA-7XXP T 460 RGZZESDI Ball 1PC29313AD012AG SA-7XXP TS 460 RGZZESDI Ball 1PC29312DA612AG SA-7XXP T 460 RGZZESDI Ball 1PC29312CB812AG SA-7XXP T 460 RGZZESDI Ball 1PC29313AC012AG SA-7XXP T 460 RGZZESDI Ball 1PC29313DD712AG SA-7XXP TS 460 RGZZESDI Ball 1PC29313BA512AG SA-7XXP T 460 RGZZESDI Ball 1PC29313BB712AG SA-7XXP T 460 RGZZESDI Ball 1PC29313DC712AG SA-7XXP T 460 RGZZESDI Ball 1PC29313CD012AG SA-7XXP Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V Weight (lbs)

139 Duty - TEFC RGZZESDI - Class I, Group D, Class II, Groups F & G, Division 1 HP RPM Frame Voltage Type DE Bearing List Price $ Mult. Sym. FL Amps* High Efficiency FL Nom. Eff. (%) TS 460 RGZZESDI Ball 1PC29313BA612AG SA-7XXP T 460 RGZZESDI Ball 1PC29313AB012AG SA-7XXP T 460 RGZZESDI Ball 1PC29313CC012AG SA-7XXP T 460 RGZZESDI Ball 1PC29314AD712AG SA-7XXP TS 460 RGZZESDI Ball 1PC29313DA512AG SA-7XXP T 460 RGZZESDI Ball 1PC29313DB712AG SA-7XXP T 460 RGZZESDI Ball 1PC29314AC712AG SA-7XXP T 460 RGZZESDI Ball 1PC29314BD612AG SA-7XXP TS 460 RGZZESDI Ball 1PC29313DA612AG SA-7XXP T 460 RGZZESDI Ball 1PC29313CB012AG SA-7XXP T 460 RGZZESDI Ball 1PC29314BC612AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PD112AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314BA512AG SA-7XXP T 460 RGZZESDI Ball 1PC29314BB612AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PC112AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PD212AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PA112AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PB112AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PC212AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PD312AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PA212AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PB212AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PC312AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PD412AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PA312AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PB312AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PC412AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PA412AG SA-7XXP TS 460 RGZZESDI Ball 1PC29314PB412AG SA-7XXP Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V Weight (lbs) Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 5-9 Dimensions

140 Introduction General Purpose Duty Duty Purpose Dimensions Duty (Variable Speed ) Description Type / Frame List Price Adder Per Frame ($) Order RGZESDI RGZZESDI S449 Code Code Pos Altitude / Ambient Rerate/Derate Y80 Z 140-S Assembly - Mounting & Terminal Box Position W-2 9+R2A 16+Z 140-S W-3 9+R3A 16+Z 140-S W S C S Bearings Sealed Ball bearings 1 L68 Z 140-S (except 2 pole, 360+ frames) Breathers and Drain Plugs T Drain SS L45 Z 140-S Crouse Hinds - UL Approved L46 Z 280-S Conduit Box - Main Orient 90 deg CCW J84 Z 140-S Orient 180 deg CCW J85 Z 140-S Orient 270 deg CCW J86 Z 140-S Conduit Box - Auxiliary for Thermostats Condulet to Main Box J12 Z 140-S Conduit Box - Auxiliary for Space Heaters Condulet to Main Box J52 Z 140-S Drip Cover Drip cover without vertical lifting K33 Z 140-S devices Export Packaging Sea Freight - Siemens Standard B09 Z 140-S Flanged End Shields C-Face with Feet 2 E C-Face without Feet G D-Flange with Feet F Grounding Provision (tapped hole on frame w/ L27 Z 140-S bolt) Hardware Stainless Steel L22 Z 140-S Lifting Eyebolt 3 L20 Z std std std std std std std std std std Insulation Fungus Protection C07 Z 140-S Leads / Terminal Blocks Burndy Hydent type YA K80 Z 140-S Sealed Leads K89 Z 140-S449 Standard Lubrication Grease Fitting / Pressure Relief L60 Z 140-S Nameplate Extra M21 Z 140-S Division 2 4 M22 Z 140-S Change (Rerate/Derate) Y80 Z 140-S Auxiliary Y82 Z 140-S Protective Devices - Windings Thermostats, normally closed, 2 per motor G S449 Standard For further details please refer to section 8 1 Sealed Ball bearings not available for 2 pole motors with frames > C face with feet for 440 frames, only available with ball bearings. 3 Lifting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required Low Voltage AC Selection and Pricing Guide

141 Duty (Variable Speed ) Description Code Order Code Pos Type / Frame List Price Adder Per Frame ($) RGZESDI RGZZESDI Rotation Arrow Bidirectional (not applicable for unidirectional K70 Z 140-S motors) Clockwise (facing ODE) K71 Z 140-S Counterclockwise (facing ODE) K72 Z 140-S Service Factor Rerate/Derate Y80 Z 140-S Shaft Seal Slinger & O Ring (4, 6, 8 Pole only) L76 Z 140-S Software Documentation in Spanish D05 Z 140-S Certificate of Compliance F00 Z 140-S Standard Transmittal F40 Z 140-S Standard Dimension Sheet F42 Z 140-S Conduit Box Dimension Sheet F44 Z 140-S Wiring Diagram F45 Z 140-S IOM F46 Z 140-S Renewal Parts F47 Z 140-S Sheets F49 Z 140-S F03 Z 140-S Testing Routine Test Report F10 Z 140-S Routine Test Report with Vibration Test F20 Z 140-S For further details please refer to section 8 1 Sealed Ball bearings not available for 2 pole motors with frames > C face with feet for 440 frames, only available with ball bearings. 3 Lifting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required. S449 Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 5-11 Dimensions

142 Introduction General Purpose Duty Duty Purpose Dimensions Options Duty Description Type / Frame List Price Adder Per Frame ($) Order RGZESDI RGZZESDI S449 Code Code Pos Assembly - Mounting & Terminal Box Position W S W S F Auxiliary boxes 1 Auxiliary conduit box location (Digit 2) XP condulet - opposite of main conduit box side J 6 Z Temperature detector device (Digit 1) Select the number that corresponds with the appropriate Temperature Detector Device to create your initial 3 digital ordering code. Thermostats 1 Space heaters 5 Balance Precision M69 Z 140-S Extra Precision M70 Z 140-S Bearings Roller Instead of Ball L65 Z std std std Insulated L66 Z 140-S Insulated - ODE only L67 Z 140-S Couplings er Supplied H10 Z Encoder - Single Output - TEFC Avtron M PPR G00 Z Avtron M PPR G01 Z 400-S Avtron M PPR G02 Z Avtron M PPR G03 Z 210-S BEI HS PPR G04 Z 140-S Dynapar HS PPR G05 Z 140-S Northstar PPR ( ) G06 Z Northstar PPR ( ) G07 Z 400-S Northstar SL PPR G08 Z Avtron HS35A G09 Z Encoder - Special Special Y75 Z 140-S449 - cf cf cf cf cf cf cf cf cf cf cf Export Packaging Special B10 Z 140-S cf cf cf cf cf cf cf cf cf cf cf Fans Bronze M10 Z 140-S Duty Group C&D, F&G, 1.0SF M82 Z Only Insulation Class H C00 Z 140-S Vacuum Pressure Impregnation (VPI) C01 Z 140-S Moisture/Powerhouse (extra C04 Z 140-S dip & bake) Tropicalization Moisture (extra dip & bake, fungus spray) C08 Z 140-S For further details please refer to section 9 For availability on Flanges and End shields as Options see page Low Voltage AC Selection and Pricing Guide

143 Options Duty Description Order Code Code Pos Type / Frame List Price Adder Per Frame ($) RGZESDI RGZZESDI Leads / Terminal Blocks Terminal Block - 3 lead only K83 Z Leads, Special Cable Length Y85 Z 140-S449 - cf cf cf cf cf cf cf cf cf cf cf Lubrication Special Grease (High & Low L57 Z 140-S Temp) (Mobil 28) Special Grease (Mobilith L58 Z 140-S SHC 100) Paint Paint - 3 Part Epoxy N01 Z 140-S (Carboline or Ameron) Paint - 2 Part Epoxy N02 Z 140-S Standard Primer Only N03 Z 140-S Standard Paint, Special Y60 Z 140-S Color Special Paint, Special Color Y61 Z 140-S cf cf cf cf cf cf cf cf cf cf cf Protective Devices - Windings PTC thermistors, 3 B S embedded temperature sensors for tripping PTC thermistors, 6 C S embedded temperature sensors for alarm and tripping KTY84-130, 2 embedded F S temperature sensors Thermocouples, coil head J Winding temperature K S protection, Stator RTD's (coil head, 1 per phase), 100Ω Platinum, complete with auxiliary box with terminal strip opposite to main box Protective Devices - Bearings Bearing thermal protection, Bearing RTDs with connection head and terminal block - both ends, 100Ω Platinum A51 Z 400-S For further details please refer to section 9 S449 Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 5-13 Dimensions

144 Introduction General Purpose Duty Duty Purpose Options Duty Description Order Code Code Pos Type / Frame List Price Adder Per Frame ($) RGZESDI RGZZESDI Shafts Carbon Steel (C4140) M57 Z 400-S Shaft DE Special to Y50 Z 140-S cf cf cf cf cf cf cf cf cf cf cf er Specifications Shaft ODE Special to Y51 Z 140-S cf cf cf cf cf cf cf cf cf cf cf er Specifications NEMA Standard Short Shaft M53 Z 140-S ODE NEMA Standard Long Shaft M52 Z 140-S ODE Shaft Grounding Brush Shaft Grounding Brush L29 Z 140-S Shaft Seal Brass Seal L84 Z Software Nonstandard Dimension F43 Z 140-S Sheet er Specific F50 Z 140-S Sheets Special Calculated F07 Z 140-S Space Heater 115V, Single Phase, A43 Z Ex. Proof Testing Routine Test Report - F12 Z 140-S (Witnessed) Complete Test F15 Z 140-S Complete Test (Witnessed) F17 Z 140-S Calibration Test F27 Z 140-S Electrical Duplicate - F36 Z 140-S (Routine Test) Electrical Duplicate (Complete Test) F37 Z 140-S Noise F30 Z 140-S Noise (Witnessed) F32 Z 140-S Routine Test Report with F22 Z 140-S Vibration Test (Witnessed) Vertical Jacking Vertical Jacking Provision M39 Z 280-S Vibration Detectors Vibraswitch Robert Shaw A66 Z 280-S malfunction detector Model D8 120VAC Provision for vibration sensors (PMC/Beta) on D.E. & O.D.E A67 Z 280-S For further details please refer to section 9 S449 Dimensions Low Voltage AC Selection and Pricing Guide

145 Options Duty Description Voltage Special Voltage V Special Voltage V Part Winding Start - 200V, 60Hz Part Winding Start - 230V, 60Hz Part Winding Start - 460V, 60Hz Part Winding Start - 575V, 60Hz Wye Start - Delta Run - 200V, 60Hz Wye Start - Delta Run - 230V, 60Hz Wye Start - Delta Run - 460V, 60Hz Wye Start - Delta Run - 575V, 60Hz Order Code Code Pos , M1Y 13+Z , M2Y 13+Z & & & & & & & &13 For further details please refer to section 9 Type / Frame List Price Adder Per Frame ($) RGZESDI RGZZESDI S S S S S S S Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 5-15 Dimensions

146 Notes Dimensions Introduction Purpose Duty Duty General Purpose Low Voltage AC Selection and Pricing Guide

147 Purpose - TEFC P-Base RGZVESD - Vertical Solid Shaft - Normal Thrust RGZVESD P-base vertical solid shaft motors are ideal for applications such as centrifugal and turbine pumps. Specifications 1 to 250 HP 1.15 service factor, 40ºC ambient Continuous thrust: Up: 355 to 1,860 lbs. Down: 380 to 2,800 lbs. 3600, 1800, 1200, or 900 RPM 3 phase, 60 Hz; 230/460 volt operation under 25 HP, 460 volt 25 HP and above; 200 & 575 volt available Class F insulation, Class B temperature rise NEMA design B, continuous duty 143 HP through 449 HP frame Features for Long Life Frame & Bearing Housings These motors feature a cast iron frame and end shields for exceptional structural integrity. A drive end T-drain, drip cover and lifting lugs are included. Rotor A offset rotor design provides improved efficiency while larger bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel shaft for maximum rotor performance. Stator/Windings Manufactured with premium electrical grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross section reduces resistance and lowers stator losses. Insulation Proprietary inverter rated NEMA Class F non-hygroscopic insulation system with Class B temperature rise, provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical surges. This insulation system meets or exceeds NEMA MG1-2006, Part 31, making all motors suitable for operation with adjustable frequency drives. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves airflow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes. Bearings Regreasable ball bearings with cast iron caps. Alemite grease fittings on the inlets, and pipe plugs on the relief ports for ease of routine maintenance. Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. High Efficiency Oversized Conduit Box Cast iron construction that is larger than industry standards, diagonally-split, neoprene-gasketed and rotatable in 90º increments for quick and easy connections. A ground lug is included. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, zinc-plated hardware, epoxy enamel paint and stainless steel nameplate resist rust and corrosion. Modifiable & All Siemens vertical motors are available with a wide variety of modifications and custom designs to meet your specific motor needs. Introduction General Purpose Duty Duty Purpose Specifications table begins on the next page Low Voltage AC Selection and Pricing Guide 6-1 Dimensions

148 Introduction General Purpose Duty Duty Purpose Dimensions Purpose - TEFC P-Base RGZVESD - Vertical Solid Shaft - Normal Thrust HP RPM Frame Voltage Type Cont. Thrust 1Yr. Life Min. Up (lbs) Down (lbs) Low Voltage AC Selection and Pricing Guide List Price $ FL FL Nom. Amps* Eff. (%) High Efficiency HP 230/460 RGZVESD PC28111BB216TA HP 230/460 RGZVESD PC28111BC316TA HP 230/460 RGZVESD PC28111DD116TA HP 230/460 RGZVESD PC28111BA216TA HP 230/460 RGZVESD PC28111BB316TA HP 230/460 RGZVESD PC28111DC116TA HP 230/460 RGZVESD PC28111DD216TA HP 230/460 RGZVESD PC28111BA316TA HP 230/460 RGZVESD PC28111BB416TA HP 230/460 RGZVESD PC28111DC216TA HP 230/460 RGZVESD PC28112AD316TA Weight (lbs) HP 230/460 RGZVESD PC28111DA116TA HP 230/460 RGZVESD PC28111DB116TA HP 230/460 RGZVESD PC28112AC316TA HP 230/460 RGZVESD PC28112AD416TA HP 230/460 RGZVESD PC28111DA216TA HP 230/460 RGZVESD PC28111DB216TA HP 230/460 RGZVESD PC28112AC416TA HP 230/460 RGZVESD PC28112BD316TA HP 230/460 RGZVESD PC28112AA316TA HP 230/460 RGZVESD PC28112AB316TA HP 230/460 RGZVESD PC28112BC316TA HP 230/460 RGZVESD PC28112BD416TA HP 230/460 RGZVESD PC28112AA416TA HP 230/460 RGZVESD PC28112AB416TA HP 230/460 RGZVESD PC28112BC416TA HP 230/460 RGZVESD PC28112CD316TA HP 230/460 RGZVESD PC28112BA316TA HP 230/460 RGZVESD PC28112BB316TA HP 230/460 RGZVESD PC28112CC316TA HP 230/460 RGZVESD PC28112CD416TA HP 230/460 RGZVESD PC28112BA416TA HP 230/460 RGZVESD PC28112BB416TA HP 230/460 RGZVESD PC28112CC416TA HP 230/460 RGZVESD PC28113AD316TA HP 460 RGZVESD PC28112CA312TA HP 460 RGZVESD PC28112CB312TA HP 460 RGZVESD PC28113AC312TA HP 460 RGZVESD PC28113AD412TA HP 460 RGZVESD PC28112CA412TA HP 460 RGZVESD PC28112CB412TA HP 460 RGZVESD PC28113AC412TA HP 460 RGZVESD PC28113CD312TA HP 460 RGZVESD PC28113AA312TA HP 460 RGZVESD PC28113AB312TA HP 460 RGZVESD PC28113CC312TA HP 460 RGZVESD PC28113CD412TA Stock Model

149 Purpose - TEFC P-Base RGZVESD - Vertical Solid Shaft - Normal Thrust HP RPM Frame Voltage Type Cont. Thrust 1Yr. Life Min. Up (lbs) Down (lbs) List Price $ FL FL Nom. Amps* Eff. (%) High Efficiency Weight (lbs) HP 460 RGZVESD PC28113AA412TA HP 460 RGZVESD PC28113AB412TA HP 460 RGZVESD PC28113CC412TA HP 460 RGZVESD PC28114AD312TA HP 460 RGZVESD PC28113CA312TA HP 460 RGZVESD PC28113CB312TA HP 460 RGZVESD PC28114AC312TA HP 460 RGZVESD PC28114AD412TA HP 460 RGZVESD PC28113CA412TA HP 460 RGZVESD PC28113CB412TA HP 460 RGZVESD PC28114AC412TA HP 460 RGZVESD PC28114HD112TA HP 460 RGZVESD PC28114AA412TA HP 460 RGZVESD PC28114AB412TA HP 460 RGZVESD PC28114HC112TA HP 460 RGZVESD PC28114HD212TA HP 460 RGZVESD PC28114HB112TA HP 460 RGZVESD PC28114HC212TA HP 460 RGZVESD PC28114HD312TA HP 460 RGZVESD PC28114HB212TA HP 460 RGZVESD PC28114HC312TA HP 460 RGZVESD PC28114HD412TA HP 460 RGZVESD PC28114HB312TA HP 460 RGZVESD PC28114HC512TA HP 460 RGZVESD PC28114HD612TA HP 460 RGZVESD PC28114HB512TA HP 460 RGZVESD PC28114HC612TA Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Stock Model Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 6-3 Dimensions

150 Introduction General Purpose Duty Duty Purpose - TEFC P-Base RGZZVESD - VSS Normal Thrust - Class I, Group D, Division 1 RGZZVESD P-base vertical solid shaft explosion-proof motors are UL listed for use in Class I, Group D, Division 1 hazardous areas and are ideal for applications such as centrifugal and turbine pumps. Specifications 1 to 250 HP 1.0 service factor, 40ºC ambient T2D temperature code Continuous thrust: Up: 355 to 1,860 lbs. Down: 380 to 2,800 lbs. 3600, 1800, 1200, or 900 RPM 3 phase, 60 Hz; 230/460 volt operation under 25 HP, 460 volt 25 HP and above; 200 & 575 volt available Class F insulation, Class B temperature rise NEMA design B, continuous duty 143 HP through 449 HP frame Features for Long Life Frame & Bearing Housings These motors feature a cast iron frame and end shields for exceptional structural integrity. A drive end sintered condensation / breather drain, drip cover, and lifting lugs are included. Rotor A unique rotor design provides improved efficiency while larger bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel shaft for maximum rotor performance. Specifications table begins on the next page Stator/Windings Manufactured with premium electrical grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross section reduces resistance and lowers stator losses. Insulation Proprietary Class F non-hygroscopic insulation system with NEMA Class B temperature rise, provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical surges. Two series-connected normally closed Class B thermostats are supplied as standard. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves airflow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes. Bearings Regreasable ball bearings with cast iron caps. Alemite grease fittings on the inlets, and pipe plugs on the relief ports for ease of routine maintenance. Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. High Efficiency Oversized Conduit Box Cast iron construction that is larger than industry standards, diagonally-split and rotatable in 90º increments for quick and easy connections. A ground lug is provided. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, zinc-plated hardware, epoxy enamel paint and stainless steel nameplate resist rust and corrosion. Modifiable & All Siemens motors are available with a wide variety of modifications and custom designs to meet your specific motor needs. Dimensions Purpose Low Voltage AC Selection and Pricing Guide

151 Purpose - TEFC P-Base RGZZVESD - VSS Normal Thrust - Class I, Group D, Division 1 HP RPM Frame Voltage Type Cont. Thrust 1Yr. Life Min. Up (lbs) Down (lbs) List Price $ Multiplier Symbol FL Amps* High Efficiency FL Nom. Eff. (%) HP 230/460 RGZZVESD PC28411BB216TG3 816 SA-7EN HP 230/460 RGZZVESD PC28411BC316TG3 998 SA-7EN HP 230/460 RGZZVESD PC28411DD116TG SA-7EN HP 230/460 RGZZVESD PC28411BA216TG3 962 SA-7EN HP 230/460 RGZZVESD PC28411BB316TG3 896 SA-7EN HP 230/460 RGZZVESD PC28411DC116TG SA-7EN HP 230/460 RGZZVESD PC28411DD216TG SA-7EN HP 230/460 RGZZVESD PC28411BA316TG3 998 SA-7EN HP 230/460 RGZZVESD PC28411BB416TG3 974 SA-7EN HP 230/460 RGZZVESD PC28411DC216TG SA-7EN HP 230/460 RGZZVESD PC28412AD316TG SA-7EN Weight (lbs) HP 230/460 RGZZVESD PC28411DA116TG SA-7EN HP 230/460 RGZZVESD PC28411DB116TG SA-7EN HP 230/460 RGZZVESD PC28412AC316TG SA-7EN HP 230/460 RGZZVESD PC28412AD416TG SA-7EN HP 230/460 RGZZVESD PC28411DA216TG SA-7EN HP 230/460 RGZZVESD PC28411DB216TG SA-7EN HP 230/460 RGZZVESD PC28412AC416TG SA-7EN HP 230/460 RGZZVESD PC28412BD316TG SA-7EN HP 230/460 RGZZVESD PC28412AA316TG SA-7EN HP 230/460 RGZZVESD PC28412AB316TG SA-7EN HP 230/460 RGZZVESD PC28412BC316TG SA-7EN HP 230/460 RGZZVESD PC28412BD416TG SA-7EN HP 230/460 RGZZVESD PC28412AA416TG SA-7EN HP 230/460 RGZZVESD PC28412AB416TG SA-7EN HP 230/460 RGZZVESD PC28412BC416TG SA-7EN HP 230/460 RGZZVESD PC28412CD316TG SA-7EN HP 230/460 RGZZVESD PC28412BA316TG SA-7EN HP 230/460 RGZZVESD PC28412BB316TG SA-7EN HP 230/460 RGZZVESD PC28412CC316TG SA-7EN HP 230/460 RGZZVESD PC28412CD416TG SA-7EN HP 230/460 RGZZVESD PC28412BA416TG SA-7EN HP 230/460 RGZZVESD PC28412BB416TG SA-7EN HP 230/460 RGZZVESD PC28412CC416TG SA-7EN HP 230/460 RGZZVESD PC28413AD316TG SA-7EN HP 460 RGZZVESD PC28412CA312TG SA-7EN HP 460 RGZZVESD PC28412CB312TG SA-7EN HP 460 RGZZVESD PC28413AC312TG SA-7EN HP 460 RGZZVESD PC28413AD412TG SA-7EN HP 460 RGZZVESD PC28412CA412TG SA-7EN HP 460 RGZZVESD PC28412CB412TG SA-7EN HP 460 RGZZVESD PC28413AC412TG SA-7EN HP 460 RGZZVESD PC28413CD312TG SA-7EN Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only Low Voltage AC Selection and Pricing Guide Stock Model *FL Amps at 460V or 575V All RGZZVESD motors will be discontinued when present stock is depleted 6-5 Introduction General Purpose Duty Duty Purpose Dimensions

152 Purpose - TEFC P-Base Introduction General Purpose Duty Duty Purpose RGZZVESD - VSS Normal Thrust - Class I, Group D, Division 1 HP RPM Frame Voltage Type Cont. Thrust 1Yr. Life Min. Up (lbs) Down (lbs) List Price $ Multiplier Symbol FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) HP 460 RGZZVESD PC28413AA312TG SA-7EN HP 460 RGZZVESD PC28413AB312TG SA-7EN HP 460 RGZZVESD PC28413CC312TG SA-7EN HP 460 RGZZVESD PC28413CD412TG SA-7EN HP 460 RGZZVESD PC28413AA412TG SA-7EN HP 460 RGZZVESD PC28413AB412TG SA-7EN HP 460 RGZZVESD PC28413CC412TG SA-7EN HP 460 RGZZVESD PC28414AD312TG SA-7EN HP 460 RGZZVESD PC28413CA312TG SA-7EN HP 460 RGZZVESD PC28413CB312TG SA-7EN HP 460 RGZZVESD PC28414AC312TG SA-7EN HP 460 RGZZVESD PC28414AD412TG SA-7EN HP 460 RGZZVESD PC28413CA412TG SA-7EN HP 460 RGZZVESD PC28413CB412TG SA-7EN HP 460 RGZZVESD PC28414AC412TG SA-7EN HP 460 RGZZVESD PC28414HD112TG SA-7EN HP 460 RGZZVESD PC28414AA412TG SA-7EN HP 460 RGZZVESD PC28414AB412TG SA-7EN HP 460 RGZZVESD PC28414HC112TG SA-7EN HP 460 RGZZVESD PC28414HD212TG SA-7EN HP 460 RGZZVESD PC28414HB112TG SA-7EN HP 460 RGZZVESD PC28414HC212TG SA-7EN HP 460 RGZZVESD PC28414HD312TG SA-7EN HP 460 RGZZVESD PC28414HB212TG SA-7EN HP 460 RGZZVESD PC28414HC312TG SA-7EN HP 460 RGZZVESD PC28414HD412TG SA-7EN HP 460 RGZZVESD PC28414HB312TG SA-7EN HP 460 RGZZVESD PC28414HC512TG SA-7EN HP 460 RGZZVESD PC28414HD612TG SA-7EN HP 460 RGZZVESD PC28414HB512TG SA-7EN HP 460 RGZZVESD PC28414HC612TG SA-7EN Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only Stock Model *FL Amps at 460V or 575V All RGZZVESD motors will be discontinued when present stock is depleted Dimensions Low Voltage AC Selection and Pricing Guide

153 Purpose - TEFC P-Base RGZVILESD - Vertical Solid Shaft - In-Line Thrust RGZVILESD motors are ideal for dependable and energy efficient operation in applications such as centrifugal and turbine pumps. Specifications 3 to 250 HP 1.15 service factor, 40ºC ambient Continuous thrust: Up: 785 to 3,735 lbs. Down: 735 to 1,550 lbs. Radial: 930 to 2,140 lbs. 3600, 1800, or 1200 RPM 3 phase, 60 Hz; 230/460 volt operation under 25 HP, 460 volt 25 HP and above; 200 & 575 volt available Class F insulation, Class B temperature rise NEMA design B, continuous duty 182LP through 449LP frame Features for Long Life Frame & Bearing Housings Vertical inline solid shaft severe duty motors feature a cast iron frame and end shields for exceptional structural integrity. A drive end T-drain, drip cover and lifting lugs are included. Rotor A unique rotor design provides improved efficiency while larger bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel shaft for maximum rotor performance. Specifications table begins on the next page Stator/Windings Manufactured with premium electrical grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross section reduces resistance, also lowering stator losses. Insulation Proprietary inverterrated Class F non-hygroscopic insulation system with NEMA Class B temperature rise, provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical surges. This insulation system meets or exceeds NEMA MG1-2006, Part 31, making all motors suitable for operation with adjustable frequency drives. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves airflow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes. Bearings Regreasable drive end is open ball bearing (182LP 256LP frames), double shielded ball bearing (284LP 449LP frames); opposite drive end is a duplex angular contact thrust bearing (143LP 449LP frames) with cast iron caps. Alemite grease fittings on the inlets, and pipe plugs on the relief ports for ease of routine maintenance. High Efficiency Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. Oversized Conduit Box Cast iron construction that is larger than industry standards, diagonally-split, neoprenegasketed and rotatable in 90º increments for quick and easy connections. Includes a ground lug and non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, zinc-plated hardware, epoxy enamel paint and stainless steel nameplate resist rust and corrosion. Modifiable All Siemens vertical motors are available with a wide variety of modifications and custom designs to meet your specific motor needs. Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 6-7 Dimensions

154 Introduction General Purpose Duty Duty Purpose Dimensions Purpose - TEFC P-Base RGZVILESD - Vertical Solid Shaft - In-Line Thrust HP RPM Frame Voltage Type Continuous Thrust 2Yr. Life Min. Up (lbs) Down (lbs) Rad. (lbs) Low Voltage AC Selection and Pricing Guide List Price $ Multiplier Symbol FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) LP 230/460 RGZVILESD PC28311DA416TA SA-7EN LP 230/460 RGZVILESD PC28311DB416TA SA-7EN LP 230/460 RGZVILESD PC28312AC516TA SA-7EN LP 230/460 RGZVILESD PC28311DA516TA SA-7EN LP 230/460 RGZVILESD PC28311DB516TA SA-7EN LP 230/460 RGZVILESD PC28312AC616TA SA-7EN LP 230/460 RGZVILESD PC28312AA516TA SA-7EN LP 230/460 RGZVILESD PC28312AB516TA SA-7EN LP 230/460 RGZVILESD PC28312BC516TA SA-7EN LP 230/460 RGZVILESD PC28312AA616TA SA-7EN LP 230/460 RGZVILESD PC28312AB616TA SA-7EN LP 230/460 RGZVILESD PC28312BC616TA SA-7EN LP 230/460 RGZVILESD PC28312BA516TA SA-7EN LP 230/460 RGZVILESD PC28312BB516TA SA-7EN LPH 230/460 RGZVILESD PC28312EC116TA SA-7EN LP 230/460 RGZVILESD PC28312BA616TA SA-7EN LP 230/460 RGZVILESD PC28312BB616TA SA-7EN LPH 230/460 RGZVILESD PC28312EC416TA SA-7EN LPH 460 RGZVILESD PC28312EA112TA SA-7EN LPH 460 RGZVILESD PC28312EB112TA SA-7EN LP 460 RGZVILESD PC28313AC512TA SA-7EN LPH 460 RGZVILESD PC28312EA412TA SA-7EN LPH 460 RGZVILESD PC28312EB412TA SA-7EN LP 460 RGZVILESD PC28313AC612TA SA-7EN LP 460 RGZVILESD PC28313AA512TA SA-7EN LP 460 RGZVILESD PC28313AB512TA SA-7EN LP 460 RGZVILESD PC28313CC512TA SA-7EN LP 460 RGZVILESD PC28313AA612TA SA-7EN LP 460 RGZVILESD PC28313AB612TA SA-7EN LP 460 RGZVILESD PC28313CC612TA SA-7EN LP 460 RGZVILESD PC28313CA512TA SA-7EN LP 460 RGZVILESD PC28313CB512TA SA-7EN LP 460 RGZVILESD PC28314AC512TA SA-7EN LP 460 RGZVILESD PC28313CA612TA SA-7EN LP 460 RGZVILESD PC28313CB612TA SA-7EN LP 460 RGZVILESD PC28314AC612TA SA-7EN LP 460 RGZVILESD PC28314AA612TA SA-7EN LP 460 RGZVILESD PC28314AB612TA SA-7EN LP 460 RGZVILESD PC28314JC112TA SA-7EN LP 460 RGZVILESD PC28314JB112TA SA-7EN LP 460 RGZVILESD PC28314JC212TA SA-7EN LP 460 RGZVILESD PC28314JB212TA SA-7EN LP 460 RGZVILESD PC28314JC312TA SA-7EN LP 460 RGZVILESD PC28314JB312TA SA-7EN LP 460 RGZVILESD PC28314JC512TA SA-7EN LP 460 RGZVILESD PC28314JB512TA SA-7EN LP 460 RGZVILESD PC28314JC612TA SA-7EN Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V Stock Model

155 Purpose - P-Base RGZZVILESD - VSS - In-Line Thrust - Class I, Group D, Division 1 RGZZVILESD P-base in-line vertical solid shaft high efficiency explosionproof motors are UL listed for use in Class I, Group D, Division 1 hazardous areas and are ideal for applications such as centrifugal and turbine pumps. Specifications 3 to 250 HP 1.0 service factor, 40ºC ambient T2D temperature code Continuous thrust: Up: 785 to 3,735 lbs. Down: 735 to 1,550 lbs. Radial: 930 to 2,140 lbs. 3600, 1800, 1200, or 900 RPM 3 phase, 60 Hz; 230/460 volt operation under 25 HP, 460 volt 25 HP and above; 200 & 575 volt available Class F insulation, Class B temperature rise NEMA design B, continuous duty 182LP through 449LP frame Features for Long Life Frame & End Bearing Housings These motors feature a cast iron frame and end shields for exceptional structural integrity. A drive end sintered condensation / breather drain, drip cover and lifting lugs are included. Rotor A unique rotor design provides improved efficiency while larger bars and end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced for extended bearing life, and includes a high strength carbon steel shaft for maximum rotor performance. Specifications table begins on the next page Stator/Windings Manufactured with premium electrical grade steel laminations and copper electrical magnet wire to lower losses for improved efficiencies. A unique stator core design lowers flux density while increasing cooling capacity. Large conductor cross section reduces resistance, also lowering stator losses. Insulation Proprietary Class F non-hygroscopic insulation system with NEMA Class B temperature rise, provides an extra margin of thermal life. Varnish system application ensures maximum wire penetration to provide protection from moisture, corrosion and electrical surges. Two series-connected normally closed Class B thermostats are supplied as standard. Cooling A bi-directional, non-sparking fan is locked and keyed to the shaft. Its design reduces windage losses, improves airflow, reduces noise and provides dependable cooling. Cast iron fan covers are provided on all frame sizes. Bearings Regreasable, drive end is open ball bearing (182LP 256LP frames), double-shielded ball bearing (284LP 449LP frames); opposite drive end is a duplex angular contact thrust bearing (143LP 449LP frames) with cast iron caps. Alemite grease fittings on the inlets, and pipe plugs on the relief ports for ease of routine maintenance. High Efficiency Lubrication A specially formulated, high temperature, polyurea based grease is used to provide more than four times the lubrication life of other greases. Oversized Conduit Box Cast iron construction that is larger than industry standards, diagonally-split and rotatable in 90º increments for quick and easy connections. A ground lug is provided. Non-wicking, clearly and permanently marked leads. Corrosion Resistance Cast iron construction, zinc-plated hardware, epoxy enamel paint and stainless steel nameplate resist rust and corrosion. Modifiable & All Siemens motors are available with a wide variety of modifications and custom designs to meet your specific motor needs. Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 6-9 Dimensions

156 Introduction General Purpose Duty Duty Purpose Dimensions Purpose - TEFC P-Base RGZZVILESD - VSS - In-Line Thrust - Class I, Group D, Division 1 HP RPM Frame Voltage Type Continuous Thrust 2Yr. Life Min. Up (lbs) Down (lbs) Rad. (lbs) Low Voltage AC Selection and Pricing Guide List Price $ Multiplier Symbol FL Amps* High Efficiency FL Nom. Eff. (%) Weight (lbs) LP 230/460 RGZZVILESD PC28611DA416TG SA-7EN LP 230/460 RGZZVILESD PC28611DB416TG SA-7EN LP 230/460 RGZZVILESD PC28612AC516TG SA-7EN LP 230/460 RGZZVILESD PC28611DA516TG SA-7EN LP 230/460 RGZZVILESD PC28611DB516TG SA-7EN LP 230/460 RGZZVILESD PC28612AC616TG SA-7EN LP 230/460 RGZZVILESD PC28612AA516TG SA-7EN LP 230/460 RGZZVILESD PC28612AB516TG SA-7EN LP 230/460 RGZZVILESD PC28612BC516TG SA-7EN LP 230/460 RGZZVILESD PC28612AA616TG SA-7EN LP 230/460 RGZZVILESD PC28612AB616TG SA-7EN LP 230/460 RGZZVILESD PC28612BC616TG SA-7EN LP 230/460 RGZZVILESD PC28612BA516TG SA-7EN LP 230/460 RGZZVILESD PC28612BB516TG SA-7EN LPH 230/460 RGZZVILESD PC28612EC116TG SA-7EN LP 230/460 RGZZVILESD PC28612BA616TG SA-7EN LP 230/460 RGZZVILESD PC28612BB616TG SA-7EN LPH 230/460 RGZZVILESD PC28612EC416TG SA-7EN LPH 460 RGZZVILESD PC28612EA112TG SA-7EN LPH 460 RGZZVILESD PC28612EB112TG SA-7EN LP 460 RGZZVILESD PC28613AC512TG SA-7EN LPH 460 RGZZVILESD PC28612EA412TG SA-7EN LPH 460 RGZZVILESD PC28612EB412TG SA-7EN LP 460 RGZZVILESD PC28613AC612TG SA-7EN LP 460 RGZZVILESD PC28613AA512TG SA-7EN LP 460 RGZZVILESD PC28613AB512TG SA-7EN LP 460 RGZZVILESD PC28613CC512TG SA-7EN LP 460 RGZZVILESD PC28613AA612TG SA-7EN LP 460 RGZZVILESD PC28613AB612TG SA-7EN LP 460 RGZZVILESD PC28613CC612TG SA-7EN LP 460 RGZZVILESD PC28613CA512TG SA-7EN LP 460 RGZZVILESD PC28613CB512TG SA-7EN LP 460 RGZZVILESD PC28614AC512TG SA-7EN LP 460 RGZZVILESD PC28613CA612TG SA-7EN LP 460 RGZZVILESD PC28613CB612TG SA-7EN LP 460 RGZZVILESD PC28614AC612TG SA-7EN LP 460 RGZZVILESD PC28614AA612TG SA-7EN LP 460 RGZZVILESD PC28614AB612TG SA-7EN LP 460 RGZZVILESD PC28614JC112TG SA-7EN LP 460 RGZZVILESD PC28614JB112TG SA-7EN LP 460 RGZZVILESD PC28614JC212TG SA-7EN LP 460 RGZZVILESD PC28614JB212TG SA-7EN LP 460 RGZZVILESD PC28614JC312TG SA-7EN LP 460 RGZZVILESD PC28614JB312TG SA-7EN LP 460 RGZZVILESD PC28614JC512TG SA-7EN LP 460 RGZZVILESD PC28614JB512TG SA-7EN LP 460 RGZZVILESD PC28614JC612TG SA-7EN Prices and specifications are subject to change without notice Stock availability subject to sale delivery for stocked motors only *FL Amps at 460V or 575V All RGZZVILESD motors will be discontinued when present stock is depleted Stock Model

157 Purpose (Vertical ) Description Code Order Code Pos RGZVESD RGZVILESD Type / Frame List Price Adder Per Frame ($) RGZZVESD RGZZVILESD Altitude / Ambient Rerate/Derate Y80 Z Conduit Box - Main Orient 90 deg CCW J84 Z Orient 180 deg CCW J85 Z Orient 270 deg CCW J86 Z Conduit Box - Auxiliary for Thermostats Condulet to Main Box J12 Z Conduit Box - Auxiliary for Space Heaters Condulet to Main Box J52 Z Grounding Provision (tapped hole on L27 Z frame w/bolt) Hardware Stainless Steel L22 Z Lifting Eyebolt 3 L20 Z Standard Standard 30 std std std std std std std std std std Duty Group D, F&G, 1.15SF M80 Z (Rerate) Insulation Fungus Protection C07 Z Leads / Terminal Blocks Burndy Hydent type YA K80 Z Sealed Leads K89 Z Standard Lubrication Grease Fitting / Pressure L60 Z Relief Nameplate Extra M21 Z Division 2 4 M22 Z Change (Rerate/Derate) Y80 Z Auxiliary Y82 Z For further details please refer to section 8 S449 Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 6-11 Dimensions

158 Introduction General Purpose Duty Duty Purpose Purpose (Vertical ) Description Code Order Code Pos Type / Frame List Price Adder Per Frame ($) RGZVESD RGZVILESD RGZZVESD RGZZVILESD Protective Devices - Windings Thermostats, normally G Standard closed, 2 per motor Rotation Arrow Bidirectional (not applicable K70 Z for uni-directional motors) Clockwise (facing ODE) K71 Z Counterclockwise (facing K72 Z ODE) Service Factor Rerate/Derate Y80 Z Software Documentation in Spanish D05 Z Certificate of Compliance F00 Z Standard Transmittal F40 Z Standard Dimension Sheet F42 Z Conduit Box Dimension F44 Z Sheet Wiring Diagram F45 Z IOM F46 Z Renewal Parts F47 Z Sheets F49 Z F03 Z Space Heater 115V, Single Phase A40 Z V, Single Phase A41 Z V, Single Phase, Div 2 A42 Z V, Single Phase, Div 2 A44 Z Testing Routine Test Report F10 Z Routine Test Report with F20 Z Vibration Test Voltage Single Voltage - 230V 11 12&13 20HP 20HP (outside leads connection only) Single Voltage - 460V (outside leads connection only) 12 12&13 20HP 20HP For further details please refer to section 8 3 Lifting eyebolt is provided as standard except where indicated for 140 Frames 4 Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required. S449 Dimensions Low Voltage AC Selection and Pricing Guide

159 Options Purpose (Vertical ) Description Type / Frame List Price Adder Per Frame ($) Order RGZVESD S449 Code Code RGZVILESD Pos Auxiliary boxes Auxiliary conduit box location (Digit 2) Condulet to main conduit J 2 Z box Auxiliary box - opposite of main conduit box side J 5 Z Temperature detector device (Digit 1) Select the number that corresponds with the appropriate Temperature Detector Device to create your initial 3 digital ordering code. Thermistors. 0 Thermostats. 1 KTY 84 Thermistor 2 Space heaters 5 Stator RTD's to auxiliary J conduit box of opposite of main box side Balance Precision M69 Z Couplings er Supplied H10 Z Export Packaging Sea Freight - Siemens B09 Z Standard Special B10 Z cf cf cf cf cf cf cf cf cf cf cf Fans Bronze M10 Z Insulation Class H C00 Z Vacuum Pressure Impregnation (VPI) C01 Z Moisture/Powerhouse (extra C04 Z dip & bake) Tropicalization Moisture (extra dip & bake, fungus spray) C08 Z For further details please refer to section 9 Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 6-13 Dimensions

160 Introduction General Purpose Duty Duty Purpose Options Purpose (Vertical ) Description Order Code Code Pos Type / Frame List Price Adder Per Frame ($) RGZVESD RGZVILESD Leads / Terminal Blocks Terminal Block - 3 lead only K83 Z Leads, Special Cable Length Y85 Z cf cf cf cf cf cf cf cf cf cf cf Lubrication Special Grease (High & Low L57 Z Temp) (Mobil 28) Special Grease (Mobilith L58 Z SHC 100) Paint Paint - 3 Part Epoxy N01 Z (Carboline or Ameron) Paint - 2 Part Epoxy N02 Z Standard Primer Only N03 Z Standard Paint, Special Color Y60 Z Special Paint, Special Color Y61 Z cf cf cf cf cf cf cf cf cf cf cf Protective Devices - Windings PTC thermistors, 3 B embedded temperature sensors for tripping PTC thermistors, 6 C embedded temperature sensors for alarm and tripping KTY84-130, 2 embedded F temperature sensors Thermocouples, coil head J Winding temperature K protection, Stator RTD's (coil head, 1 per phase), 100Ω Platinum, complete with auxiliary box with terminal strip opposite to main box Protective Devices - Bearings Bearing thermal protection, A51 Z Bearing RTDs with connection head and terminal block - both ends, 100Ω Platinum Shafts Carbon Steel (C4140) M57 Z Shaft DE Special to er Specifications Y50 Z cf cf cf cf cf cf cf cf cf cf cf For further details please refer to section 9 S449 Dimensions Low Voltage AC Selection and Pricing Guide

161 Options Purpose (Vertical ) Description Order Code Code Pos Type / Frame List Price Adder Per Frame ($) RGZVESD RGZVILESD Software Nonstandard Dimension F43 Z Sheet er Specific F50 Z Sheets Special Calculated F07 Z Space Heater 115V, Single Phase, Ex. A43 Z Proof Testing Routine Test Report - F12 Z (Witnessed) Complete Test F15 Z Complete Test (Witnessed) F17 Z Calibration Test F27 Z Electrical Duplicate - F36 Z (Routine Test) Electrical Duplicate (Complete Test) F37 Z Noise F30 Z Noise (Witnessed) F32 Z Routine Test Report with F22 Z Vibration Test (Witnessed) Vibration Detectors Vibraswitch Robert Shaw A66 Z malfunction detector Model D8 120VAC Provision for vibration A67 Z sensors (PMC/Beta) on D.E. & O.D.E Voltage Special Voltage V , M1Y 13+Z Special Voltage V , M2Y 13+Z Part Winding Start - 200V, Hz &13 Part Winding Start - 230V, Hz &13 Part Winding Start - 460V, Hz &13 Part Winding Start - 575V, Hz &13 Wye Start - Delta Run V, 60Hz &13 Wye Start - Delta Run V, 60Hz &13 Wye Start - Delta Run - 460V, 60Hz & Wye Start - Delta Run - 575V, 60Hz & S449 Introduction General Purpose Duty Duty Purpose For further details please refer to section Low Voltage AC Selection and Pricing Guide 6-15 Dimensions

162 Notes Dimensions Introduction Purpose Duty Duty General Purpose Low Voltage AC Selection and Pricing Guide

163 IEC - TEFCs 1LA7 The 1LA7 motors, with their wide variety of options, fit in every drive system concept and cover more than 90% of all imaginable applications worldwide, suitable for indoor and outdoor applications where light weight and excellent price/performance ratio and high degree of operational reliability are required. This powerful energy-saving motor is less harmful to the environment thanks to reduction in CO 2 emission. Specifications 90W to 18.5kW Overload reserve in continuous mode (SF 1.1) Dual Frequency rated 3000, 1500, 1000, 750 RPM 3600, 1800, 1200, 900 RPM 3 phase, 50 Hz; 230VD/400VY and 60 Hz; 460VY 3 phase, 50 Hz; 400VD/690VY and 60 Hz; 460VD All commonly used voltages (50Hz and 60Hz) available EU/CEMEP efficiency classification EFF2 (Improved efficiency) Class F insulation, Class B temperature rise Continuous Duty, Suitable for Converted fed operation CE Marked, IEC NEMA MG1-12 compatibility available UL and CSA label marks available 56 through 160 frame Features for Long Life Frame & End Shields Cast aluminum construction for exceptional heat dissipation and structural integrity. All motors are designed with degree of protection IP55 (IEC 529), suitable for use in dusty or damp surroundings, ready for their use in the tropics. (IP56 and IP65 available) Specifications table begins on the next page Rotor A unique offset laminated rotor core design provides improved efficiency while larger bars and Aluminum end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced (IEC ) for extended bearing life. Stator/Windings Manufactured with premium electrical grade steel laminations and the finest copper electrical magnet wire for lower losses and improved efficiencies. A unique stator core design lowers flux density and increases cooling capacity. Large conductor cross section reduces resistance, also lowering stator losses. Insulation DURIGNIT IR 2000, inverter-compatible up to 500 V, optionally up to 690 V. This insulation system comprised of high-grade enameled wires and insulating sheet materials combine with solvent-free impregnating resin. The system ensures a high level of mechanical and electrical strength as well as good serviceability and long motor life. The insulation offers general protection for the windings against corrosive gases, vapors, dust, oil and increased humidity, and resists the normal stresses of vibration. Cooling are fitted with a radial-flow fan which functions independently of the direction of rotation (cooling method IC 411 to DIN EN ). The material of the external cooling fans is reinforced plastic. This material is tested and certified for a 20 year lifetime. Fan cowls are made of corrosion protected steel plate. Bearings The bearing nominal life is specified by standard calculation (DIN ISO 281) and is achieved or exceeds by 90% if used according to instructions, if the operating conditions are below average a bearing life of 100,000 (Lh10 hours) can be achieved. Standard Efficiency Lubrication The grease life, for pre-lubricated motors, is tailored to the bearing life. In those cases where re-lubrication is chosen, the motors are provided with a grease retaining system that prevents grease from entering the motor. Siemens IEC motors use a lithium based grease. Conduit Box Cast aluminum construction, top mounted as standard, the terminal box can be ordered to either side of the motor or be rotated 90º or 180º (frames size 80 and above) providing a more flexible outing. In addition to the standard terminal box earthing, an external earthing is also made available for all motors upon request. Corrosion Resistance Zinc-plated hardware, epoxy enamel paint and aluminum nameplate resist rust and corrosion. (Stainless steel hardware also available) Flexible All Siemens IEC motors are available with a wide variety of options to meet your specific motor needs. Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 7-1 Dimensions

164 Introduction General Purpose Duty Duty Purpose Dimensions IEC - TEFCs 1LA7 - Foot Mounted kw 50Hz kw 60Hz RPM 50Hz Frame Type DE Bearing Part Number Low Voltage AC Selection and Pricing Guide List Price $ Mult. Symb. FL Amps 50Hz Standard Efficiency FL Nom. Eff. 50Hz Weight (kg) M 1LA7 BALL 1LA7050-4AB CA-EF % M 1LA7 BALL 1LA7050-2AA CA-EF % M 1LA7 BALL 1LA7053-4AB CA-EF % M 1LA7 BALL 1LA7063-6AB CA-EF % M 1LA7 BALL 1LA7070-8AB CA-EF % M 1LA7 BALL 1LA7053-2AA CA-EF % M 1LA7 BALL 1LA7060-4AB SA-EF % M 1LA7 BALL 1LA7073-8AB CA-EF % M 1LA7 BALL 1LA7060-2AA CA-EF % M 1LA7 BALL 1LA7063-4AB SA-EF % M 1LA7 BALL 1LA7070-6AA CA-EF % M 1LA7 BALL 1LA7080-8AB CA-EF % M 1LA7 BALL 1LA7063-2AA CA-EF % M 1LA7 BALL 1LA7070-4AB CA-EF % M 1LA7 BALL 1LA7073-6AA CA-EF % M 1LA7 BALL 1LA7083-8AB CA-EF % M 1LA7 BALL 1LA7070-2AA CA-EF % M 1LA7 BALL 1LA7073-4AB CA-EF % M 1LA7 BALL 1LA7080-6AA CA-EF % S 1LA7 BALL 1LA7090-8AB CA-EF % M 1LA7 BALL 1LA7073-2AA CA-EF % M 1LA7 BALL 1LA7080-4AA SA-EF % M 1LA7 BALL 1LA7083-6AA SA-EF % L 1LA7 BALL 1LA7096-8AB CA-EF % M 1LA7 BALL 1LA7080-2AA CA-EF % M 1LA7 BALL 1LA7083-4AA CA-EF % S 1LA7 BALL 1LA7090-6AA CA-EF % L 1LA7 BALL 1LA7106-8AB CA-EF % M 1LA7 BALL 1LA7083-2AA CA-EF % S 1LA7 BALL 1LA7090-4AA CA-EF % L 1LA7 BALL 1LA7096-6AA CA-EF % L 1LA7 BALL 1LA7107-8AB CA-EF % S 1LA7 BALL 1LA7090-2AA CA-EF % L 1LA7 BALL 1LA7096-4AA CA-EF % L 1LA7 BALL 1LA7106-6AA CA-EF % M 1LA7 BALL 1LA7113-8AB CA-EF % L 1LA7 BALL 1LA7096-2AA CA-EF % L 1LA7 BALL 1LA7106-4AA CA-EF % M 1LA7 BALL 1LA7113-6AA CA-EF % S 1LA7 BALL 1LA7130-8AB CA-EF % L 1LA7 BALL 1LA7106-2AA CA-EF % L 1LA7 BALL 1LA7107-4AA CA-EF % S 1LA7 BALL 1LA7130-6AA CA-EF % M 1LA7 BALL 1LA7133-8AB CA-EF % M 1LA7 BALL 1LA7113-2AA CA-EF % M 1LA7 BALL 1LA7113-4AA CA-EF % M 1LA7 BALL 1LA7133-6AA CA-EF % M 1LA7 BALL 1LA7163-8AB CA-EF % S 1LA7 BALL 1LA7130-2AA CA-EF % S 1LA7 BALL 1LA7130-4AA CA-EF % M 1LA7 BALL 1LA7134-6AA CA-EF % M 1LA7 BALL 1LA7164-8AB CA-EF % 74.0 Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Stock Model

165 IEC - TEFCs 1LA7 - Foot Mounted kw 50Hz kw 60Hz RPM 50Hz Frame Type DE Bearing Part Number List Price $ Mult. Symb. FL Amps 50Hz Standard Efficiency FL Nom. Eff. 50Hz S 1LA7 BALL 1LA7131-2AA CA-EF % M 1LA7 BALL 1LA7133-4AA CA-EF % M 1LA7 BALL 1LA7163-6AA CA-EF % L 1LA7 BALL 1LA7166-8AB CA-EF % M 1LA7 BALL 1LA7163-2AA CA-EF % M 1LA7 BALL 1LA7163-4AA CA-EF % L 1LA7 BALL 1LA7166-6AA CA-EF % M 1LA7 BALL 1LA7164-2AA CA-EF % L 1LA7 BALL 1LA7166-4AA CA-EF % L 1LA7 BALL 1LA7166-2AA CA-EF % 86.0 Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Weight (kg) Stock Model Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 7-3 Dimensions

166 Introduction General Purpose Duty Duty Purpose Dimensions IEC - TEFCs 1LA7 - Foot Mounted and PTC (1x Phase) kw 50Hz kw 60Hz RPM Frame Type DE Bearing Part Number Low Voltage AC Selection and Pricing Guide List Price $ Mult. Symb. FL Amps 50Hz Standard Efficiency FL Nom. Eff. 50Hz Weight (kg) M 1LA7 BALL 1LA7050-4AB10-Z A CA-EF % M 1LA7 BALL 1LA7050-2AA10-Z A CA-EF % M 1LA7 BALL 1LA7053-4AB10-Z A CA-EF % M 1LA7 BALL 1LA7063-6AB10-Z A CA-EF % M 1LA7 BALL 1LA7070-8AB10-Z A CA-EF % M 1LA7 BALL 1LA7053-2AA10-Z A CA-EF % M 1LA7 BALL 1LA7060-4AB10-Z A CA-EF % M 1LA7 BALL 1LA7073-8AB10-Z A CA-EF % M 1LA7 BALL 1LA7060-2AA10-Z A CA-EF % M 1LA7 BALL 1LA7063-4AB10-Z A SA-EF % M 1LA7 BALL 1LA7070-6AA10-Z A CA-EF % M 1LA7 BALL 1LA7080-8AB10-Z A CA-EF % M 1LA7 BALL 1LA7063-2AA10-Z A CA-EF % M 1LA7 BALL 1LA7070-4AB10-Z A CA-EF % M 1LA7 BALL 1LA7073-6AA10-Z A CA-EF % M 1LA7 BALL 1LA7083-8AB10-Z A CA-EF % M 1LA7 BALL 1LA7070-2AA10-Z A CA-EF % M 1LA7 BALL 1LA7073-4AB10-Z A CA-EF % M 1LA7 BALL 1LA7080-6AA10-Z A CA-EF % S 1LA7 BALL 1LA7090-8AB10-Z A CA-EF % M 1LA7 BALL 1LA7073-2AA10-Z A SA-EF % M 1LA7 BALL 1LA7080-4AA10-Z A CA-EF % M 1LA7 BALL 1LA7083-6AA10-Z A CA-EF % L 1LA7 BALL 1LA7096-8AB10-Z A CA-EF % M 1LA7 BALL 1LA7080-2AA10-Z A SA-EF % M 1LA7 BALL 1LA7083-4AA10-Z A CA-EF % S 1LA7 BALL 1LA7090-6AA10-Z A CA-EF % L 1LA7 BALL 1LA7106-8AB10-Z A CA-EF % M 1LA7 BALL 1LA7083-2AA10-Z A CA-EF % S 1LA7 BALL 1LA7090-4AA10-Z A CA-EF % L 1LA7 BALL 1LA7096-6AA10-Z A CA-EF % L 1LA7 BALL 1LA7107-8AB10-Z A CA-EF % S 1LA7 BALL 1LA7090-2AA10-Z A CA-EF % L 1LA7 BALL 1LA7096-4AA10-Z A CA-EF % L 1LA7 BALL 1LA7106-6AA10-Z A CA-EF % M 1LA7 BALL 1LA7113-8AB60-Z A CA-EF % L 1LA7 BALL 1LA7096-2AA10-Z A CA-EF % L 1LA7 BALL 1LA7106-4AA10-Z A CA-EF % M 1LA7 BALL 1LA7113-6AA60-Z A CA-EF % S 1LA7 BALL 1LA7130-8AB60-Z A CA-EF % L 1LA7 BALL 1LA7106-2AA10-Z A CA-EF % L 1LA7 BALL 1LA7107-4AA10-Z A CA-EF % S 1LA7 BALL 1LA7130-6AA60-Z A CA-EF % M 1LA7 BALL 1LA7133-8AB60-Z A CA-EF % M 1LA7 BALL 1LA7113-2AA60-Z A CA-EF % M 1LA7 BALL 1LA7113-4AA60-Z A CA-EF % M 1LA7 BALL 1LA7133-6AA60-Z A CA-EF % M 1LA7 BALL 1LA7163-8AB60-Z A CA-EF % S 1LA7 BALL 1LA7130-2AA60-Z A CA-EF % S 1LA7 BALL 1LA7130-4AA60-Z A CA-EF % M 1LA7 BALL 1LA7134-6AA60-Z A CA-EF % M 1LA7 BALL 1LA7164-8AB60-Z A CA-EF % 74.0 Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Stock Model

167 IEC - TEFCs 1LA7 - Foot Mounted and PTC (1x Phase) kw 50Hz kw 60Hz RPM Frame Type DE Bearing Part Number List Price $ Mult. Symb. FL Amps 50Hz Standard Efficiency FL Nom. Eff. 50Hz S 1LA7 BALL 1LA7131-2AA60-Z A CA-EF % M 1LA7 BALL 1LA7133-4AA60-Z A CA-EF % M 1LA7 BALL 1LA7163-6AA60-Z A CA-EF % L 1LA7 BALL 1LA7166-8AB60-Z A CA-EF % M 1LA7 BALL 1LA7163-2AA60-Z A CA-EF % M 1LA7 BALL 1LA7163-4AA60-Z A CA-EF % L 1LA7 BALL 1LA7166-6AA60-Z A CA-EF % M 1LA7 BALL 1LA7164-2AA60-Z A CA-EF % L 1LA7 BALL 1LA7166-4AA60-Z A CA-EF % L 1LA7 BALL 1LA7166-2AA60-Z A CA-EF % 86.0 Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Weight (kg) Stock Model Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 7-5 Dimensions

168 Introduction General Purpose Duty Duty Purpose Dimensions IEC - TEFCs 1LA7 - B5 Flange, Footless (w/o canopy) kw 50Hz kw 60Hz RPM Frame Type DE Bearing Part Number Low Voltage AC Selection and Pricing Guide List Price $ Mult. Symb. FL Amps 50Hz Standard Efficiency FL Nom. Eff. 50Hz M 1LA7 BALL 1LA7050-4AB CA-EF % M 1LA7 BALL 1LA7050-2AA CA-EF % M 1LA7 BALL 1LA7053-4AB CA-EF % M 1LA7 BALL 1LA7063-6AB CA-EF % M 1LA7 BALL 1LA7070-8AB CA-EF % M 1LA7 BALL 1LA7053-2AA CA-EF % 3.0 Weight (kg) M 1LA7 BALL 1LA7060-4AB SA-EF % M 1LA7 BALL 1LA7073-8AB CA-EF % M 1LA7 BALL 1LA7060-2AA CA-EF % M 1LA7 BALL 1LA7063-4AB SA-EF % M 1LA7 BALL 1LA7070-6AA CA-EF % M 1LA7 BALL 1LA7080-8AB CA-EF % M 1LA7 BALL 1LA7063-2AA SA-EF % M 1LA7 BALL 1LA7070-4AB SA-EF % M 1LA7 BALL 1LA7073-6AA SA-EF % M 1LA7 BALL 1LA7083-8AB CA-EF % M 1LA7 BALL 1LA7070-2AA CA-EF % M 1LA7 BALL 1LA7073-4AB SA-EF % M 1LA7 BALL 1LA7080-6AA SA-EF % S 1LA7 BALL 1LA7090-8AB CA-EF % M 1LA7 BALL 1LA7073-2AA SA-EF % M 1LA7 BALL 1LA7080-4AA SA-EF % M 1LA7 BALL 1LA7083-6AA CA-EF % L 1LA7 BALL 1LA7096-8AB CA-EF % M 1LA7 BALL 1LA7080-2AA CA-EF % M 1LA7 BALL 1LA7083-4AA CA-EF % S 1LA7 BALL 1LA7090-6AA CA-EF % L 1LA7 BALL 1LA7106-8AB CA-EF % M 1LA7 BALL 1LA7083-2AA CA-EF % S 1LA7 BALL 1LA7090-4AA CA-EF % L 1LA7 BALL 1LA7096-6AA CA-EF % L 1LA7 BALL 1LA7107-8AB CA-EF % S 1LA7 BALL 1LA7090-2AA CA-EF % L 1LA7 BALL 1LA7096-4AA CA-EF % L 1LA7 BALL 1LA7106-6AA CA-EF % M 1LA7 BALL 1LA7113-8AB CA-EF % L 1LA7 BALL 1LA7096-2AA SA-EF % L 1LA7 BALL 1LA7106-4AA CA-EF % M 1LA7 BALL 1LA7113-6AA CA-EF % S 1LA7 BALL 1LA7130-8AB CA-EF % L 1LA7 BALL 1LA7106-2AA CA-EF % L 1LA7 BALL 1LA7107-4AA CA-EF % S 1LA7 BALL 1LA7130-6AA CA-EF % M 1LA7 BALL 1LA7133-8AB CA-EF % M 1LA7 BALL 1LA7113-2AA CA-EF % M 1LA7 BALL 1LA7113-4AA CA-EF % M 1LA7 BALL 1LA7133-6AA CA-EF % M 1LA7 BALL 1LA7163-8AB CA-EF % 64.0 Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Stock Model

169 EC - TEFCs 1LA7 - B5 Flange, Footless (w/o canopy) kw 50Hz kw 60Hz RPM Frame Type DE Bearing Part Number List Price $ Mult. Symb. FL Amps 50Hz Standard Efficiency FL Nom. Eff. 50Hz S 1LA7 BALL 1LA7130-2AA CA-EF % S 1LA7 BALL 1LA7130-4AA CA-EF % M 1LA7 BALL 1LA7134-6AA CA-EF % M 1LA7 BALL 1LA7164-8AB CA-EF % S 1LA7 BALL 1LA7131-2AA CA-EF % M 1LA7 BALL 1LA7133-4AA CA-EF % M 1LA7 BALL 1LA7163-6AA CA-EF % L 1LA7 BALL 1LA7166-8AB CA-EF % 94.0 Weight (kg) M 1LA7 BALL 1LA7163-2AA SA-EF % M 1LA7 BALL 1LA7163-4AA CA-EF % L 1LA7 BALL 1LA7166-6AA CA-EF % M 1LA7 BALL 1LA7164-2AA CA-EF % L 1LA7 BALL 1LA7166-4AA CA-EF % L 1LA7 BALL 1LA7166-2AA CA-EF % 86.0 Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Stock Model Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 7-7 Dimensions

170 Introduction General Purpose Duty Duty Purpose Dimensions IEC - TEFCs 1LA7 -B14 Flange, Footless (w/o canopy) kw 50Hz kw 60Hz RPM Frame Type DE Bearing Part Number Low Voltage AC Selection and Pricing Guide List Price $ Mult. Symb. FL Amps 50Hz Standard Efficiency FL Nom. Eff. 50Hz M 1LA7 BALL 1LA7050-4AB CA-EF % M 1LA7 BALL 1LA7050-2AA CA-EF % M 1LA7 BALL 1LA7053-4AB CA-EF % M 1LA7 BALL 1LA7063-6AB CA-EF % M 1LA7 BALL 1LA7070-8AB CA-EF % M 1LA7 BALL 1LA7053-2AA CA-EF % 3.0 Weight (kg) M 1LA7 BALL 1LA7060-4AB SA-EF % M 1LA7 BALL 1LA7073-8AB CA-EF % M 1LA7 BALL 1LA7060-2AA SA-EF % M 1LA7 BALL 1LA7063-4AB SA-EF % M 1LA7 BALL 1LA7070-6AA CA-EF % M 1LA7 BALL 1LA7080-8AB CA-EF % M 1LA7 BALL 1LA7063-2AA CA-EF % M 1LA7 BALL 1LA7070-4AB SA-EF % M 1LA7 BALL 1LA7073-6AA SA-EF % M 1LA7 BALL 1LA7083-8AB CA-EF % M 1LA7 BALL 1LA7070-2AA SA-EF % M 1LA7 BALL 1LA7073-4AB SA-EF % M 1LA7 BALL 1LA7080-6AA SA-EF % S 1LA7 BALL 1LA7090-8AB CA-EF % M 1LA7 BALL 1LA7073-2AA SA-EF % M 1LA7 BALL 1LA7080-4AA SA-EF % M 1LA7 BALL 1LA7083-6AA SA-EF % L 1LA7 BALL 1LA7096-8AB CA-EF % M 1LA7 BALL 1LA7080-2AA CA-EF % M 1LA7 BALL 1LA7083-4AA SA-EF % S 1LA7 BALL 1LA7090-6AA CA-EF % L 1LA7 BALL 1LA7106-8AB CA-EF % M 1LA7 BALL 1LA7083-2AA CA-EF % S 1LA7 BALL 1LA7090-4AA CA-EF % L 1LA7 BALL 1LA7096-6AA CA-EF % L 1LA7 BALL 1LA7107-8AB CA-EF % S 1LA7 BALL 1LA7090-2AA CA-EF % L 1LA7 BALL 1LA7096-4AA SA-EF % L 1LA7 BALL 1LA7106-6AA CA-EF % M 1LA7 BALL 1LA7113-8AB CA-EF % L 1LA7 BALL 1LA7096-2AA CA-EF % L 1LA7 BALL 1LA7106-4AA CA-EF % M 1LA7 BALL 1LA7113-6AA CA-EF % S 1LA7 BALL 1LA7130-8AB CA-EF % L 1LA7 BALL 1LA7106-2AA CA-EF % L 1LA7 BALL 1LA7107-4AA CA-EF % S 1LA7 BALL 1LA7130-6AA CA-EF % M 1LA7 BALL 1LA7133-8AB CA-EF % M 1LA7 BALL 1LA7113-2AA CA-EF % M 1LA7 BALL 1LA7113-4AA CA-EF % M 1LA7 BALL 1LA7133-6AA CA-EF % M 1LA7 BALL 1LA7163-8AB CA-EF % 64.0 Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Stock Model

171 IEC - TEFCs 1LA7 -B14 Flange, Footless (w/o canopy) kw 50Hz kw 60Hz RPM Frame Type DE Bearing Part Number List Price $ Mult. Symb. FL Amps 50Hz Standard Efficiency FL Nom. Eff. 50Hz S 1LA7 BALL 1LA7130-2AA CA-EF % S 1LA7 BALL 1LA7130-4AA CA-EF % M 1LA7 BALL 1LA7134-6AA CA-EF % M 1LA7 BALL 1LA7164-8AB CA-EF % S 1LA7 BALL 1LA7131-2AA CA-EF % M 1LA7 BALL 1LA7133-4AA CA-EF % M 1LA7 BALL 1LA7163-6AA CA-EF % L 1LA7 BALL 1LA7166-8AB CA-EF % M 1LA7 BALL 1LA7163-2AA CA-EF % M 1LA7 BALL 1LA7163-4AA CA-EF % L 1LA7 BALL 1LA7166-6AA CA-EF % M 1LA7 BALL 1LA7164-2AA CA-EF % L 1LA7 BALL 1LA7166-4AA CA-EF % L 1LA7 BALL 1LA7166-2AA CA-EF % 86.0 Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Weight (kg) Stock Model Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 7-9 Dimensions

172 Introduction IEC - TEFCs 1LA6 - Foot Mounted Standard Efficiency General Purpose Duty Duty Purpose The 1LA6 motors, with their wide variety of options, fit in every drive system concept and cover more than 90% of all imaginable worldwide. They are suitable for indoor and outdoor applications where excellent price/performance ratio and high degree of operational reliability in severe operating atmospheres are required. This powerful energy-saving motor is less harmful to the environment thanks to reduction in CO2 emission. These industry workhorses are ideal for use in chemical processing, mining, foundry, pulp and paper, waste management and petro/chemical applications. Specifications 0.75W to 18.5kW Dual Frequency rated 3000, 1500, 1000 RPM - 50 Hz 3600, 1800, 1200 RPM - 60 Hz 3 phase, 50 Hz; 230VD/400VY and 60 Hz 460VY 3 phase, 50 Hz; 400VD/690VY and 60 Hz 460VD All commonly used voltages (50 Hz and 60 Hz) available EU/CEMEP efficiency classification EFF2 (Improved efficiency) Class F insulation, Class B temperature rise Continuous Duty, Suitable for Converted fed operation CE Marked, IEC NEMA MG1-12 available UL and CSA label marks available 100 through 160 frame Features for Long Life Frame & End Shields Cast Iron construction for high degree of operational reliability in aggressive atmospheres. All motors are designed for IP55 (IEC 529), suitable for use in dusty or damp surroundings, ready for their use in the tropics. (IP56 and IP65 available) Rotor A unique offset laminated rotor core design provides improved efficiency while larger bars and Aluminum end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced (IEC ) for extended bearing life. Stator/Windings Manufactured with premium electrical grade steel laminations and the finest copper electrical magnet wire for lower losses and improved efficiencies. A unique stator core design lowers flux density and increases cooling capacity. Large conductor cross section reduces resistance, also lowering stator losses. Insulation DURIGNIT IR 2000, inverter-compatible up to 500 V, optionally up to 690 V. This insulation system comprised of high-grade enameled wires and insulating sheet materials combine with solvent-free impregnating resin. The system ensures a high level of mechanical and electrical strength as well as good serviceability and long motor life. The insulation offers general protection for the windings against corrosive gases, vapors, dust, oil and increased humidity, and resists the normal stresses of vibration. Cooling are fitted with a radial-flow fan which functions independently of the direction of rotation (cooling method IC 411 to DIN EN ). The material of the external cooling fans is reinforced plastic. This material is tested and certified for a 20 year lifetime. Fan cowls are made of corrosion protected steel plate. Bearings The bearing nominal life is specified by standard calculation (DIN ISO 281) and is achieved or exceeds by 90% if used according to instructions, if the operating conditions are below average a bearing life of 100,000 (Lh10 hours) can be achieved. Lubrication The grease life, for pre-lubricated motors, is tailored to the bearing life. In those cases where re-lubrication is chosen, the motors are provided with a grease retaining system that prevents grease from entering the motor. Siemens IEC motors use a lithium based grease. Conduit Box Cast Iron-construction, top mounted as standard, the terminal box can be ordered to either side of the motor or be rotated 90º or 180º, providing a more flexible mounting. In addition to the standard terminal box earthing, an external earthing is also made available for all motors upon request. Corrosion Resistance Zinc-plated hardware, epoxy enamel paint and aluminum nameplate resist rust and corrosion. (Stainless steel hardware also available) Flexible All Siemens IEC motors are available with a wide variety of options to meet your specific motor needs. Dimensions Specifications table begins on the next page Low Voltage AC Selection and Pricing Guide

173 IEC - TEFCs 1LA6 - Foot Mounted kw 50Hz kw 60Hz RPM Frame Type DE Bearing Part Number List Price $ Mult. Symb. FL Amps 50Hz Standard Efficiency FL Nom. Eff. 50Hz L 1LA6 BALL 1LA6106-8AB CA-EF % L 1LA6 BALL 1LA6107-8AB CA-EF % L 1LA6 BALL 1LA6106-6AA CA-EF % M 1LA6 BALL 1LA6113-8AB CA-EF % L 1LA6 BALL 1LA6106-4AA CA-EF % M 1LA6 BALL 1LA6113-6AA CA-EF % S 1LA6 BALL 1LA6130-8AB CA-EF % L 1LA6 BALL 1LA6106-2AA CA-EF % L 1LA6 BALL 1LA6107-4AA CA-EF % S 1LA6 BALL 1LA6130-6AA CA-EF % M 1LA6 BALL 1LA6133-8AB CA-EF % M 1LA6 BALL 1LA6113-2AA CA-EF % M 1LA6 BALL 1LA6113-4AA CA-EF % M 1LA6 BALL 1LA6133-6AA CA-EF % M 1LA6 BALL 1LA6163-8AB CA-EF % S 1LA6 BALL 1LA6130-2AA CA-EF % S 1LA6 BALL 1LA6130-4AA CA-EF % M 1LA6 BALL 1LA6134-6AA CA-EF % 66.0 Weight (kg) M 1LA6 BALL 1LA6164-8AB CA-EF % S 1LA6 BALL 1LA6131-2AA CA-EF % M 1LA6 BALL 1LA6133-4AA CA-EF % M 1LA6 BALL 1LA6163-6AA CA-EF % L 1LA6 BALL 1LA6166-8AB CA-EF % M 1LA6 BALL 1LA6163-2AA CA-EF % M 1LA6 BALL 1LA6163-4AA CA-EF % L 1LA6 BALL 1LA6166-6AA CA-EF % M 1LA6 BALL 1LA6164-2AA CA-EF % L 1LA6 BALL 1LA6166-4AA CA-EF % L 1LA6 BALL 1LA6166-2AA CA-EF % Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Stock Model Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 7-11 Dimensions

174 Introduction IEC - TEFCs 1LA9 High Efficiency General Purpose Duty Duty The 1LA9 motors, with their wide variety of options, fit in every drive system concept and cover more than 90% of all imaginable applications worldwide, suitable for indoor and outdoor applications where light weight and excellent price/performance ratio and high degree of operational reliability are required. This powerful energy-saving motor is less harmful to the environment thanks to reduction in CO 2 emission. Specifications 90W to 18.5kW 1.15 Service Factor, 40º C ambient Dual Frequency rated 3000, 1500, 1000 RPM - 50 Hz 3600, 1800, 1200 RPM - 60 Hz 3 phase, 50 Hz, 230VD/400VY and 60 Hz, 460VY 3 phase, 50 Hz, 400VD/690VY and 60 Hz, 460VD Special voltages (50 Hz and 60 Hz) available Meets or exceeds EPAct efficiency standards (CC 032A) Class F insulation, Class B temperature rise Continuous Duty, Suitable for Converted fed operation CE Marked, IEC NEMA MG1-12 available UL and CSA label marks available 56 through 160 frame Features for Long Life Frame & End Shields Cast aluminum construction for exceptional heat dissipation and structural integrity. All motors are designed with degree of protection IP55 (IEC 529), suitable for use in dusty or damp surroundings, ready for their use in the tropics. (IP56 and IP65 available) Rotor A unique offset laminated rotor core design provides improved efficiency while larger bars and Aluminum end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced (IEC ) for extended bearing life. Stator/Windings Manufactured with premium electrical grade steel laminations and the finest copper electrical magnet wire for lower losses and improved efficiencies. A unique stator core design lowers flux density and increases cooling capacity. Large conductor cross section reduces resistance, also lowering stator losses. Insulation DURIGNIT IR 2000, inverter-compatible up to 500 V, optionally up to 690 V. This insulation system comprised of high-grade enameled wires and insulating sheet materials combine with solvent-free impregnating resin. The system ensures a high level of mechanical and electrical strength as well as good serviceability and long motor life. The insulation offers general protection for the windings against corrosive gases, vapors, dust, oil and increased humidity, and resists the normal stresses of vibration. Cooling are fitted with a radial flow fan which functions independently of the direction of rotation (cooling method IC 411 to DIN EN ). The material of the external cooling fans is reinforced plastic. This material is tested and certified for a 20 year lifetime. Fan cowls are made of corrosion protected steel plate. Bearings The bearing nominal life is specified by standard calculation (DIN ISO 281) and is achieved or exceeds by 90% if used according to instructions, if the operating conditions are below average a bearing life of 100,000 (Lh10 hours) can be achieved. Lubrication The grease life, for pre-lubricated motors, is tailored to the bearing life. In those cases where re-lubrication is chosen, the motors are provided with a grease retaining system that prevents grease from entering the motor. Siemens IEC motors use a lithium based grease Conduit Box Cast aluminumconstruction, top mounted as standard, the terminal box can be ordered to either side of the motor or be rotated 90º or 180º (frames size 80 and above), providing a more flexible mounting. In addition to the standard terminal box earthing, an external earthing is also made available for all motors. Corrosion Resistance Zinc-plated hardware, epoxy enamel paint and aluminum nameplate resist rust and corrosion. (Stainless steel hardware also available) Flexible All Siemens IEC motors are available with a wide variety of options to meet your specific motor needs. Specifications table begins on the next page Dimensions Purpose Low Voltage AC Selection and Pricing Guide

175 IEC - TEFCs 1LA9 - Foot Mounted kw 50Hz Power HP 60Hz 50Hz RPM 60Hz Frame Type DE Bearing List Price $ Mult. Symb. FL Current High Efficiency FL Nom. Eff M 1LA9 BALL 1LA9050-4KA CA-EF % 63.0% M 1LA9 BALL 1LA9050-2KA CA-EF % 70.0% M 1LA9 BALL 1LA9053-4KA CA-EF % 64.0% M 1LA9 BALL 1LA9053-2KA CA-EF % 71.0% M 1LA9 BALL 1LA9060-4KA CA-EF % 69.0% M 1LA9 BALL 1LA9060-2KA CA-EF % 71.0% M 1LA9 BALL 1LA9063-4KA CA-EF % 65.0% M 1LA9 BALL 1LA9063-2KA CA-EF % 72.0% M 1LA9 BALL 1LA9070-4KA CA-EF % 69.0% M 1LA9 BALL 1LA9070-2KA CA-EF % 72.0% M 1LA9 BALL 1LA9073-4KA CA-EF % 70.0% M 1LA9 BALL 1LA9073-2KA CA-EF % 73.0% M 1LA9 BALL 1LA9080-4KA CA-EF % 75.5% M 1LA9 BALL 1LA9080-2KA CA-EF % 75.5% v 50Hz 460v 60Hz 400v 50Hz 460v 60Hz Low Voltage AC Selection and Pricing Guide Weight (kg) M 1LA9 BALL 1LA9083-4KA SA-EF % 82.5% S 1LA9 BALL 1LA9090-6KA SA-EF % 80.0% M 1LA9 BALL 1LA9083-2KA SA-EF % 82.5% S 1LA9 BALL 1LA9090-4KA SA-EF % 84.0% L 1LA9 BALL 1LA9096-6KA SA-EF % 85.5% S 1LA9 BALL 1LA9090-2KA SA-EF % 84.0% L 1LA9 BALL 1LA9096-4KA SA-EF % 84.0% L 1LA9 BALL 1LA9106-6KA CA-EF % 86.5% L 1LA9 BALL 1LA9096-2KA SA-EF % 85.5% L 1LA9 BALL 1LA9106-4KA SA-EF % 87.5% M 1LA9 BALL 1LA9113-6KA SA-EF % 87.5% L 1LA9 BALL 1LA9106-2KA CA-EF % 86.5% L 1LA9 BALL 1LA9107-4KA CA-EF % 87.5% M 1LA9 BALL 1LA9113-2KA SA-EF % 87.5% M 1LA9 BALL 1LA9113-4KA SA-EF % 87.5% M 1LA9 BALL 1LA9133-6KA CA-EF % 87.5% S 1LA9 BALL 1LA9130-2KA SA-EF % 88.5% S 1LA9 BALL 1LA9130-4KA SA-EF % 89.5% M 1LA9 BALL 1LA9134-6KA CA-EF % 89.5% S 1LA9 BALL 1LA9131-2KA SA-EF % 89.5% M 1LA9 BALL 1LA9133-4KA SA-EF % 89.5% M 1LA9 BALL 1LA9163-6KA CA-EF % 89.5% M 1LA9 BALL 1LA9163-2KA SA-EF % 90.2% M 1LA9 BALL 1LA9163-4KA SA-EF % 91.0% L 1LA9 BALL 1LA9166-6KA CA-EF % 90.2% M 1LA9 BALL 1LA9164-2KA SA-EF % 90.2% L 1LA9 BALL 1LA9166-4KA SA-EF % 91.0% L 1LA9 BALL 1LA9166-2KA SA-EF % 91.0% Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Stock Model 7-13 Introduction General Purpose Duty Duty Purpose Dimensions

176 IEC - TEFCs Introduction 1LA9 - Foot Mounted and PTC (1x Phase) High Efficiency General Purpose kw 50Hz Power HP 60Hz RPM 50Hz 60Hz Frame Type DE Bearing List Price $ Mult. Symb. FL Current 400v 50Hz 460v 60Hz FL Nom. Eff. 400v 50Hz 460v 60Hz Weight (kg) Stock Model Duty M 1LA9 BALL 1LA9050-4KA10-Z A CA-EF % M 1LA9 BALL 1LA9050-2KA10-Z A CA-EF % 70.0% M 1LA9 BALL 1LA9053-4KA10-Z A CA-EF % 64.0% M 1LA9 BALL 1LA9053-2KA10-Z A CA-EF % 71.0% M 1LA9 BALL 1LA9060-4KA10-Z A CA-EF % 69.0% M 1LA9 BALL 1LA9060-2KA10-Z A CA-EF % 71.0% M 1LA9 BALL 1LA9063-4KA10-Z A CA-EF % 65.0% M 1LA9 BALL 1LA9063-2KA10-Z A CA-EF % 72.0% M 1LA9 BALL 1LA9070-4KA10-Z A CA-EF % 69.0% M 1LA9 BALL 1LA9070-2KA10-Z A CA-EF % 72.0% M 1LA9 BALL 1LA9073-4KA10-Z A CA-EF % 70.0% M 1LA9 BALL 1LA9073-2KA10-Z A CA-EF % 73.0% M 1LA9 BALL 1LA9080-4KA10-Z A CA-EF % 75.5% M 1LA9 BALL 1LA9080-2KA10-Z A CA-EF % 75.5% M 1LA9 BALL 1LA9083-4KA10-Z A SA-EF % 82.5% S 1LA9 BALL 1LA9090-6KA10-Z A CA-EF % 80.0% M 1LA9 BALL 1LA9083-2KA10-Z A CA-EF % 82.5% S 1LA9 BALL 1LA9090-4KA10-Z A CA-EF % 84.0% L 1LA9 BALL 1LA9096-6KA10-Z A CA-EF % 85.5% S 1LA9 BALL 1LA9090-2KA10-Z A CA-EF % 84.0% L 1LA9 BALL 1LA9096-4KA10-Z A CA-EF % 84.0% L 1LA9 BALL 1LA9106-6KA10-Z A CA-EF % 86.5% L 1LA9 BALL 1LA9096-2KA10-Z A SA-EF % 85.5% L 1LA9 BALL 1LA9106-4KA10-Z A CA-EF % 87.5% M 1LA9 BALL 1LA9113-6KA60-Z A CA-EF % 87.5% L 1LA9 BALL 1LA9106-2KA10-Z A CA-EF % 86.5% L 1LA9 BALL 1LA9107-4KA10-Z A CA-EF % 87.5% M 1LA9 BALL 1LA9113-2KA60-Z A SA-EF % 87.5% M 1LA9 BALL 1LA9113-4KA60-Z A SA-EF % 87.5% M 1LA9 BALL 1LA9133-6KA60-Z A CA-EF % 87.5% S 1LA9 BALL 1LA9130-2KA60-Z A SA-EF % 88.5% S 1LA9 BALL 1LA9130-4KA60-Z A SA-EF % 89.5% M 1LA9 BALL 1LA9134-6KA60-Z A CA-EF % 89.5% S 1LA9 BALL 1LA9131-2KA60-Z A SA-EF % 89.5% M 1LA9 BALL 1LA9133-4KA60-Z A CA-EF % 89.5% M 1LA9 BALL 1LA9163-6KA60-Z A CA-EF % 89.5% M 1LA9 BALL 1LA9163-2KA60-Z A SA-EF % 90.2% M 1LA9 BALL 1LA9163-4KA60-Z A SA-EF % 91.0% L 1LA9 BALL 1LA9166-6KA60-Z A CA-EF % 90.2% M 1LA9 BALL 1LA9164-2KA60-Z A CA-EF % 90.2% L 1LA9 BALL 1LA9166-4KA60-Z A SA-EF % 91.0% L 1LA9 BALL 1LA9166-2KA60-Z A CA-EF % 91.0% Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Dimensions Duty Purpose Low Voltage AC Selection and Pricing Guide

177 IEC - TEFCs 1LA9 - B5 Flange, Footless (w/o canopy) Power kw 50Hz HP 60Hz RPM 50Hz 60Hz Frame Type DE Bearing List Price $ Mult. Symb. FL Current 400v 50Hz 460v 60Hz FL Nom. Eff. 400v 50Hz High Efficiency 460v 60Hz Weight (kg) Stock Model Introduction General Purpose M 1LA9 BALL 1LA9050-4KA CA-EF % M 1LA9 BALL 1LA9050-2KA CA-EF % 70.0% M 1LA9 BALL 1LA9053-4KA CA-EF % 64.0% M 1LA9 BALL 1LA9053-2KA CA-EF % 71.0% M 1LA9 BALL 1LA9060-4KA CA-EF % 69.0% M 1LA9 BALL 1LA9060-2KA CA-EF % 71.0% M 1LA9 BALL 1LA9063-4KA CA-EF % 65.0% M 1LA9 BALL 1LA9063-2KA CA-EF % 72.0% M 1LA9 BALL 1LA9070-4KA CA-EF % 69.0% M 1LA9 BALL 1LA9070-2KA CA-EF % 72.0% M 1LA9 BALL 1LA9073-4KA CA-EF % 70.0% M 1LA9 BALL 1LA9073-2KA CA-EF % 73.0% M 1LA9 BALL 1LA9080-4KA CA-EF % 75.5% M 1LA9 BALL 1LA9080-2KA CA-EF % 75.5% M 1LA9 BALL 1LA9083-4KA SA-EF % 82.5% S 1LA9 BALL 1LA9090-6KA CA-EF % 80.0% M 1LA9 BALL 1LA9083-2KA SA-EF % 82.5% S 1LA9 BALL 1LA9090-4KA SA-EF % 84.0% L 1LA9 BALL 1LA9096-6KA SA-EF % 85.5% S 1LA9 BALL 1LA9090-2KA SA-EF % 84.0% L 1LA9 BALL 1LA9096-4KA SA-EF % 84.0% L 1LA9 BALL 1LA9106-6KA CA-EF % 86.5% L 1LA9 BALL 1LA9096-2KA SA-EF % 85.5% L 1LA9 BALL 1LA9106-4KA SA-EF % 87.5% M 1LA9 BALL 1LA9113-6KA SA-EF % 87.5% L 1LA9 BALL 1LA9106-2KA SA-EF % 86.5% L 1LA9 BALL 1LA9107-4KA SA-EF % 87.5% M 1LA9 BALL 1LA9113-2KA SA-EF % 87.5% M 1LA9 BALL 1LA9113-4KA SA-EF % 87.5% M 1LA9 BALL 1LA9133-6KA CA-EF % 87.5% S 1LA9 BALL 1LA9130-2KA SA-EF % 88.5% S 1LA9 BALL 1LA9130-4KA SA-EF % 89.5% M 1LA9 BALL 1LA9134-6KA SA-EF % 89.5% S 1LA9 BALL 1LA9131-2KA SA-EF % 89.5% M 1LA9 BALL 1LA9133-4KA SA-EF % 89.5% M 1LA9 BALL 1LA9163-6KA SA-EF % 89.5% M 1LA9 BALL 1LA9163-2KA CA-EF % 90.2% M 1LA9 BALL 1LA9163-4KA SA-EF % 91.0% L 1LA9 BALL 1LA9166-6KA CA-EF % 90.2% M 1LA9 BALL 1LA9164-2KA CA-EF % 90.2% L 1LA9 BALL 1LA9166-4KA CA-EF % 91.0% L 1LA9 BALL 1LA9166-2KA CA-EF % 91.0% Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 7-15 Dimensions

178 IEC - TEFCs Introduction General Purpose Duty Duty Purpose 1LA9 - B14 Flange, Footless (w/o canopy) kw 50Hz Power HP 60Hz 50Hz RPM 60Hz Frame Type DE Bearing List Price $ Mult. Symb. FL Current 400v 50Hz 460v 60Hz High Efficiency FL Nom. Eff. 400v 50Hz 460v 60Hz Weight (kg) M 1LA9 BALL 1LA9050-4KA CA-EF % 63.0% M 1LA9 BALL 1LA9050-2KA CA-EF % 70.0% M 1LA9 BALL 1LA9053-4KA CA-EF % 64.0% M 1LA9 BALL 1LA9053-2KA CA-EF % 71.0% M 1LA9 BALL 1LA9060-4KA CA-EF % 69.0% M 1LA9 BALL 1LA9060-2KA CA-EF % 71.0% M 1LA9 BALL 1LA9063-4KA CA-EF % 65.0% M 1LA9 BALL 1LA9063-2KA CA-EF % 72.0% M 1LA9 BALL 1LA9070-4KA CA-EF % 69.0% M 1LA9 BALL 1LA9070-2KA CA-EF % 72.0% M 1LA9 BALL 1LA9073-4KA CA-EF % 70.0% M 1LA9 BALL 1LA9073-2KA CA-EF % 73.0% M 1LA9 BALL 1LA9080-4KA CA-EF % 75.5% M 1LA9 BALL 1LA9080-2KA CA-EF % 75.5% M 1LA9 BALL 1LA9083-4KA SA-EF % 82.5% S 1LA9 BALL 1LA9090-6KA CA-EF % 80.0% M 1LA9 BALL 1LA9083-2KA CA-EF % 82.5% S 1LA9 BALL 1LA9090-4KA CA-EF % 84.0% L 1LA9 BALL 1LA9096-6KA CA-EF % 85.5% S 1LA9 BALL 1LA9090-2KA SA-EF % 84.0% L 1LA9 BALL 1LA9096-4KA CA-EF % 84.0% L 1LA9 BALL 1LA9106-6KA CA-EF % 86.5% L 1LA9 BALL 1LA9096-2KA CA-EF % 85.5% L 1LA9 BALL 1LA9106-4KA SA-EF % 87.5% M 1LA9 BALL 1LA9113-6KA CA-EF % 87.5% L 1LA9 BALL 1LA9106-2KA CA-EF % 86.5% L 1LA9 BALL 1LA9107-4KA SA-EF % 87.5% M 1LA9 BALL 1LA9113-2KA CA-EF % 87.5% M 1LA9 BALL 1LA9113-4KA CA-EF % 87.5% M 1LA9 BALL 1LA9133-6KA CA-EF % 87.5% S 1LA9 BALL 1LA9130-2KA CA-EF % 88.5% S 1LA9 BALL 1LA9130-4KA CA-EF % 89.5% M 1LA9 BALL 1LA9134-6KA CA-EF % 89.5% S 1LA9 BALL 1LA9131-2KA CA-EF % 89.5% M 1LA9 BALL 1LA9133-4KA CA-EF % 89.5% M 1LA9 BALL 1LA9163-6KA CA-EF % 89.5% M 1LA9 BALL 1LA9163-2KA CA-EF % 90.2% M 1LA9 BALL 1LA9163-4KA CA-EF % 91.0% L 1LA9 BALL 1LA9166-6KA CA-EF % 90.2% M 1LA9 BALL 1LA9164-2KA CA-EF % 90.2% L 1LA9 BALL 1LA9166-4KA CA-EF % 91.0% L 1LA9 BALL 1LA9166-2KA CA-EF % 91.0% Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Stock Model Dimensions Low Voltage AC Selection and Pricing Guide

179 IEC - TEFCs 1LG6 The 1LG6 series of IEC motors are ideal for both indoor and outdoor applications and in severe operating atmospheres. These industry workhorses are ideal for use in chemical processing, mining, foundry, pulp and paper, waste management and petro/chemical applications. Specifications 18.5kW to 200kW 1.15 service factor, 40 C ambient Dual Frequency rated 3000, 1500, 1000 RPM - 50 Hz 3600, 1800, 1200 RPM - 60 Hz 3 phase, 50 Hz; 230VD/400VY and 60 Hz; 460VY 3 phase, 50 Hz; 400VD/690VY and 60 Hz; 460VD Special voltages (50 Hz and 60 Hz) available Increase Energy Saving EU efficency class EFF1 Meets or exceeds EPAct efficiency standards (CC 032A) Class F insulation, Class B temperature rise Continuous Duty, Suitable for Converted fed operation CE Marked, IEC NEMA MG1-12 UL and CSA marks available 180 through 315 frames Features for Long Life Frame & End Shields Cast Iron construction for exceptional structural integrity. All motors are designed for IP55 (IEC 529), suitable for use in dusty or damp surroundings, ready for their use in the tropics. (IP56 and IP65 available) Rotor A unique offset laminated rotor core design provides improved efficiency while larger bars and Aluminum end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced (IEC ) for extended bearing life. Specifications table begins on the next page Stator/Windings Manufactured with premium electrical grade steel laminations and the finest copper electrical magnet wire for lower losses and improved efficiencies. A unique stator core design lowers flux density and increases cooling capacity. Large conductor cross section reduces resistance, also lowering stator losses. Insulation DURIGNIT IR 2000, inverter-compatible up to 500 V, optionally up to 690 V. This insulation system comprised of high-grade enameled wires and insulating sheet materials combine with solvent-free impregnating resin. The system ensures a high level of mechanical and electrical strength as well as good serviceability and long motor life. The insulation offers general protection for the windings against corrosive gases, vapors, dust, oil and increased humidity, and resists the normal stresses of vibration. Cooling are fitted with a radial flow fan which functions independently of the direction of rotation (cooling method IC 411 to DIN EN ). The material of the external cooling fans is reinforced plastic. This material is tested and certified for a 20 year lifetime. Fan cowls are made of corrosion protected steel plate. Bearings Non-regreasable bearings, but optionally available with regreasing devices up to frame size 250 (Standard from frame 280 and above). The bearing nominal life is specified by standard calculation (DIN ISO 281) and is achieved or exceeds by 90% if used properly, if the operating conditions are below average a bearing life of 100,000 (Lh10 hours) can be achieved. Lubrication The grease life, for pre-lubricated motors, is tailored to the bearing life. For re-lubricated bearings, the motors are provided with a grease retaining system with the provision that when the grease containing chamber is full of old grease the grease is then ejected to the outside of the motor. High Efficiency Conduit Box The top mounted, Cast aluminum-construction terminal box (frames 225 and below, cast iron construction available as an option) and the Cast Iron-construction (frame 250 and above) can be ordered to the Right or left hand side of the motor as well as rotated 90º and 180º. Corrosion Resistance Zinc-plated hardware, epoxy enamel paint and aluminum nameplate resist rust and corrosion. (Stainless steel hardware also available) Flexible All Siemens IEC motors are available with a wide variety of options to meet your specific motor needs Low Voltage AC Selection and Pricing Guide 7-17 Introduction General Purpose Duty Duty Purpose Dimensions

180 IEC - TEFCs Introduction 1LG6 - Foot Mounted High Efficiency General Purpose kw 50Hz Power HP 60Hz 50Hz RPM 60Hz Frame Type DE Bearing List Price $ Mult. Symb. FL Current 400v 50Hz 460v 60Hz FL Nom. Eff. 400v 50Hz 460v 60Hz Weight (kg) Stock Model Duty Duty L 1LG6 BALL 1LG6186-6AA SA-EF % 91.0% M 1LG6 BALL 1LG6183-4AA SA-EF % 92.4% L 1LG6 BALL 1LG6206-6AA CA-EF % 91.7% M 1LG6 BALL 1LG6183-2AA SA-EF % 93.6% L 1LG6 BALL 1LG6186-4AA CA-EF % 92.4% L 1LG6 BALL 1LG6207-6AA CA-EF % 91.7% L 1LG6 BALL 1LG6206-2AA CA-EF % 92.4% L 1LG6 BALL 1LG6207-4AA CA-EF % 93.0% M 1LG6 BALL 1LG6223-6AA CA-EF % 93.0% L 1LG6 BALL 1LG6207-2AA CA-EF % 92.4% S 1LG6 BALL 1LG6220-4AA CA-EF % 93.6% M 1LG6 BALL 1LG6253-6AA CA-EF % 93.0% M 1LG6 BALL 1LG6223-2AA CA-EF % 94.1% M 1LG6 BALL 1LG6223-4AA CA-EF % 94.1% S 1LG6 BALL 1LG6280-6AA CA-EF % 94.1% M 1LG6 BALL 1LG6253-2AA CA-EF % 93.6% M 1LG6 BALL 1LG6253-4AA CA-EF % 94.5% M 1LG6 BALL 1LG6283-6AA CA-EF % 94.5% S 1LG6 BALL 1LG6280-2AB CA-EF % 95.0% S 1LG6 BALL 1LG6280-4AA CA-EF % 95.0% S 1LG6 BALL 1LG6310-6AA CA-EF % 94.5% M 1LG6 BALL 1LG6283-2AB CA-EF % 95.0% M 1LG6 BALL 1LG6283-4AA CA-EF % 95.0% M 1LG6 BALL 1LG6313-6AA CA-EF % 94.5% S 1LG6 BALL 1LG6310-2AB CA-EF % 94.5% S 1LG6 BALL 1LG6310-4AA CA-EF % 95.0% L 1LG6 BALL 1LG6316-6AA CA-EF % 95.0% M 1LG6 BALL 1LG6313-2AB CA-EF % 95.0% M 1LG6 BALL 1LG6313-4AA CA-EF % 95.4% L 1LG6 BALL 1LG6317-6AA CA-EF % 95.4% L 1LG6 BALL 1LG6316-2AB CA-EF % 95.4% L 1LG6 BALL 1LG6316-4AA CA-EF % 95.4% L 1LG6 BALL 1LG6318-6AA CA-EF % 95.4% L 1LG6 BALL 1LG6317-2AB CA-EF % 95.4% L 1LG6 BALL 1LG6317-4AA CA-EF % 95.8% Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Dimensions Purpose Low Voltage AC Selection and Pricing Guide

181 IEC - TEFCs 1LG6 - Foot Mounted and PTC (1x Phase) kw 50Hz Power HP 60Hz RPM 50Hz 60Hz Frame Type DE Bearing List Price $ Mult. Symb. FL Current 400v 50Hz 460v 60Hz High Efficiency FL Nom. Eff. 400v 50Hz 460v 60Hz Weight (kg) Stock Model Introduction General Purpose L 1LG6 BALL 1LG6186-6AA60-Z A CA-EF % 91.0% M 1LG6 BALL 1LG6183-4AA60-Z A CA-EF % 92.4% L 1LG6 BALL 1LG6206-6AA60-Z A CA-EF % 91.7% M 1LG6 BALL 1LG6183-2AA60-Z A CA-EF % 93.6% L 1LG6 BALL 1LG6186-4AA60-Z A SA-EF % 92.4% L 1LG6 BALL 1LG6207-6AA60-Z A CA-EF % 91.7% L 1LG6 BALL 1LG6206-2AA60-Z A SA-EF % 92.4% L 1LG6 BALL 1LG6207-4AA60-Z A SA-EF % 93.0% M 1LG6 BALL 1LG6223-6AA60-Z A CA-EF % 93.0% L 1LG6 BALL 1LG6207-2AA60-Z A SA-EF % 92.4% S 1LG6 BALL 1LG6220-4AA60-Z A SA-EF % 93.6% M 1LG6 BALL 1LG6253-6AA60-Z A CA-EF % 93.0% M 1LG6 BALL 1LG6223-2AA60-Z A CA-EF % 94.1% M 1LG6 BALL 1LG6223-4AA60-Z A CA-EF % 94.1% S 1LG6 BALL 1LG6280-6AA60-Z A CA-EF % 94.1% M 1LG6 BALL 1LG6253-2AA60-Z A CA-EF % 93.6% M 1LG6 BALL 1LG6253-4AA60-Z A SA-EF % 94.5% M 1LG6 BALL 1LG6283-6AA60-Z A CA-EF % 94.5% S 1LG6 BALL 1LG6280-2AB60-Z A CA-EF % 95.0% S 1LG6 BALL 1LG6280-4AA60-Z A SA-EF % 95.0% S 1LG6 BALL 1LG6310-6AA60-Z A CA-EF % 94.5% M 1LG6 BALL 1LG6283-2AB60-Z A CA-EF % 95.0% M 1LG6 BALL 1LG6283-4AA60-Z A SA-EF % 95.0% M 1LG6 BALL 1LG6313-6AA60-Z A CA-EF % 94.5% S 1LG6 BALL 1LG6310-2AB60-Z A CA-EF % 94.5% S 1LG6 BALL 1LG6310-4AA60-Z A SA-EF % 95.0% L 1LG6 BALL 1LG6316-6AA60-Z A CA-EF % 95.0% M 1LG6 BALL 1LG6313-2AB60-Z A CA-EF % 95.0% M 1LG6 BALL 1LG6313-4AA60-Z A CA-EF % 95.4% L 1LG6 BALL 1LG6317-6AA60-Z A CA-EF % 95.4% L 1LG6 BALL 1LG6316-2AB60-Z A CA-EF % 95.4% L 1LG6 BALL 1LG6316-4AA60-Z A CA-EF % 95.4% L 1LG6 BALL 1LG6318-6AA60-Z A CA-EF % 95.4% L 1LG6 BALL 1LG6317-2AB60-Z A CA-EF % 95.4% L 1LG6 BALL 1LG6317-4AA60-Z A CA-EF % 95.8% Duty Duty Purpose Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Low Voltage AC Selection and Pricing Guide 7-19 Dimensions

182 Introduction General Purpose Duty Duty Purpose Dimensions Options IEC Standard Description Order Type / Frame Code Pos. 1LA6 1LA7 1LA9 1LG6 Voltage 230VD / 400VY 50 Hz - 460VY 60Hz VD / 690VY 50 Hz - 460VD 60Hz See Additional Voltages Below Additional Voltages 440V D 60Hz L2R Z 460V D 60Hz L2T Z 575V D 60Hz L2V Z 220VD / 380VY 50Hz L1R Z 380VD / 660VY 50Hz L1L Z 415VD 50Hz L1D Z Feet & Flanges B3 Foot Monted - IMB IMV5 / IMV6 (No canopy) B5 Flange - IMB5 IMV3 / IMV1 (No canopy) B14 Flange - IMB14 IMV19 / IMV18 (No canopy) B5 Flange - IMV1 with canopy B5 Flange with Feet - IMB35 (No canopy) B14 Flange with Feet - IMB34 (No canopy) Motor Protection 3 x PTC Thermistors Tripping - VFD Zone2 A10 Z x PTC Thermistors Trippinig A11 Z x PTC Thermistors Alarm and Tripping A12 Z Motor temp. sensor KTY A23 Z Temperature sensor Tripping A31 Z X RTD PT100 Alarm and Tripping A60 Z Cooling Temperature & Insulation Increased air humidity/temperature C19 Z to 60 g per m3 of air THCL.F, acc. to B, Cooling Temp. 45ºC, C22 Z Power reduction 4% THCL.F, acc. to B, Cooling Temp. 50ºC, C23 Z Power reduction 8% THCL.F, acc. to B, Cooling Temp. 55ºC, C24 Z Power reduction 13% THCL.F, acc. to B, Cooling Temp. 60ºC, C25 Z Power reduction 18% Increased air humidity/temperature 60 to 100 g per m3 of air C26 Z External earthing L13 Z Country Certification CCC China Compulsory Certification (Only 1LA7 and 1LA9) 1) D01 Z Electrical acc. to NEMA MG1-1 D30 Z (Standard for 1LA9 and 1LG6) Designed to UL with recognition mark D31 Z China Ex-Zone 2 Certificate D32 Z Canadian standards (CSA) D40 Z Zone 2 Version for Zone 2 main operation M72 Z Version for Zone 2 VFD operation M73 Z Prices and specifications are subject to change without notice Low Voltage AC Selection and Pricing Guide

183 List Price Adder Per Frame ($) Introduction General Purpose ) Duty Duty Purpose Consult Factory Standard Standard Low Voltage AC Selection and Pricing Guide 7-21 Dimensions

184 Introduction General Purpose Duty Duty Purpose Dimensions Options IEC Standard Description Order Type / Frame Code Pos. 1LA6 1LA7 1LA9 1LG6 Degree of Protection Degree of protection IP65 K50 Z Degree of protection IP56 K52 Z Condensation drain holes L12 Z Heating and Ventilation Anti-condensation heating for 230V K45 Z Consult with factory for Zone 2 Anti-condensation heating for 115V K46 Z Consult with factory for Zone 2 Metal Fan K35 Z Steel plate fan cover L36 Z Connection Box Terminal Box on Right Hand Side K09 Z (View from DE) Terminal Box on Left Hand Side K10 Z (View from DE) Rotation of terminal box 90º K83 Z (entry from DE) Rotation of terminal box 90º K84 Z (entry from NDE) Cast Iron Terminal Box K15 Z Standard for 1LA6 motors Paint Special Paint Finish on RAL7030 K26 Z Primed Only K24 Z Special Paint Finish on RAL Y See Table Below 2) Bearings & Lubrication Bearing for increased cantilever forces K20 Z Regreasing device K40 Z Test Certificates & Auxiliary Nameplates Auxiliary Nameplate with customer data Y82 Z Routine Test Certificate 3.1 acc. EN B02 Z Type test with heat run, Horizontal motors F83 Z CCC Certificate Requirements 2 Pole : 2.2kw 4 Pole : 1.1kw 6 Pole : 0.75kw8 Pole : 0.55kw 2 Other Colors in RAL RAL Color Name RAL Color Name 1015 Light Ivory 5017 Traffic Blue 1019 Grey Beige 5018 Teal Blue 2003 Pastel Orange 5019 Capri Blue 2004 Pure Orange 6019 Patel Green 3007 Balck Red 7000 Squirrel 5007 Brilliant Blue 7004 Signal Grey 5009 Azure Blue 7011 Iron Grey 5010 Gentian Blue 7016 Anthracite Grey 5012 Light Blue 7022 Umber Grey 5015 Sky Blue 7033 Cement Grey Prices and specifications are subject to change without notice Low Voltage AC Selection and Pricing Guide

185 List Price Adder Per Frame ($) Standard Introduction General Purpose Duty Standard Standard Duty Purpose Standard Low Voltage AC Selection and Pricing Guide 7-23 Dimensions

186 Introduction General Purpose Duty Duty IEC - TEFCs 1MJ6/1MJ7 Siemens explosion-protected motors go further than the basic safety requirements. Our rugged EEx motors are completely reliable even under the most extreme conditions and under hazardous environments such as in chemical plants, the oil industry or in gas works. They comply with the strictest safety standards for the protection of life, machines and environment. All explosion-protected motors from Siemens have been tested by the German Federal Institute of Science and Technology (PTB) or by the German Coal and Steel Technology Co. (DMT). Specifications.25kW to 132kW Guideline 94/9/94EG, ATEX 100a 3000, 1500, 1000 or 750 RPM 3 Phase, 50 Hz; 230D/400Y V 3 Phase, 50 Hz; 400D/690Y V Special voltages (50 Hz and 60 Hz) available Increase Energy Saving EU efficiency class EFF2 Class F insulation, Class B temperature rise Continuous Duty Suitable for Converted fed operation CE Marked, IEC 60034, IEC through 315 frames Features for Long Life Frame & End Shields Cast Iron construction for high degree of operational reliability in aggressive atmospheres. All motors are designed for IP55 (IEC 529), suitable for use in dusty or damp surroundings, ready for their use in the tropics. (IP56 available) Specifications table begins on the next page Rotor A unique offset laminated rotor core design provides improved efficiency while larger bars and Aluminum end rings reduce resistance for lower rotor losses. Each die cast aluminum rotor assembly is dynamically balanced (IEC ) for extended bearing life Stator/Windings Manufactured with premium electrical grade steel laminations and the finest copper electrical magnet wire for lower losses and improved efficiencies. A unique stator core design lowers flux density and increases cooling capacity. Large conductor cross section reduces resistance, also lowering stator losses. Insulation DURIGNIT IR 2000, inverter-compatible up to 500 V, optionally up to 690 V. This insulation system comprised high-grade enameled wires and insulating sheet materials combine with solvent-freeimpregnating resin. The system ensures a high level of mechanical and electrical strength as well as good serviceability and long motor life. The insulation offers general protection for the windings against corrosive gases, vapors, dust, oil and increased humidity, and resists the normal stresses of vibration. Cooling are fitted with a radial-flow fan which functions independently of the direction of rotation (cooling method IC 411 to DIN EN ). The material of the external cooling fans is reinforced plastic. This material is tested and certified for a 20 year lifetime. Fan cowls are made of corrosion protected steel plate. Bearings The bearing nominal life is specified by standard calculation (DIN ISO 281) and is achieved or exceeds by 90% if used according to instructions, if the operating conditions are below average a bearing life of 100,000 (Lh10 hours) can be achieved. Explosion Proof Lubrication The grease life, for pre-lubricated motors, is tailored to the bearing life. In those cases where re-lubrication is chosen, the motors are provided with a grease retaining system that prevents grease from entering the motor. Siemens IEC motors use lithium based grease. Conduit Box Aluminum-construction for frames up to 160M, Cast Iron construction for frames 160L and above, top mounted as standard. The terminal box can be ordered to either side of the motor or be rotated 90º or 180º (frames size 80 and above), providing a more flexible mounting. Corrosion Resistance Zinc-plated hardware, epoxy enamel paint and aluminum nameplate resist rust and corrosion. (Stainless steel hardware also available) Flexible All Siemens IEC motors are available with a wide variety of options to meet your specific motor needs. Dimensions Purpose Low Voltage AC Selection and Pricing Guide

187 IEC - TEFCs 1MJ6 - Foot Mounted kw 50Hz kw 60Hz RPM rame Type DE Bearing Part Number List Price $ Mult. Symb. FL Amps 50Hz FL Nom. Eff. 50Hz M 1MJ6 BALL 1MJ6070-4CB CA-EXD % M 1MJ6 BALL 1MJ6073-6CA CA-EXD % M 1MJ6 BALL 1MJ6070-2CA CA-EXD % M 1MJ6 BALL 1MJ6073-4CB CA-EXD % M 1MJ6 BALL 1MJ6080-6CA CA-EXD % L 1MJ6 BALL 1MJ6096-8CB CA-EXD % M 1MJ6 BALL 1MJ6073-2CA CA-EXD % M 1MJ6 BALL 1MJ6080-4CA CA-EXD % M 1MJ6 BALL 1MJ6083-6CA CA-EXD % L 1MJ6 BALL 1MJ6097-8CB CA-EXD % M 1MJ6 BALL 1MJ6080-2CA CA-EXD % M 1MJ6 BALL 1MJ6083-4CA CA-EXD % L 1MJ6 BALL 1MJ6096-6CA CA-EXD % L 1MJ6 BALL 1MJ6106-8CB CA-EXD % M 1MJ6 BALL 1MJ6083-2CA CA-EXD % L 1MJ6 BALL 1MJ6096-4CA CA-EXD % L 1MJ6 BALL 1MJ6097-6CA CA-EXD % L 1MJ6 BALL 1MJ6107-8CB CA-EXD % L 1MJ6 BALL 1MJ6096-2CA CA-EXD % L 1MJ6 BALL 1MJ6097-4CA CA-EXD % L 1MJ6 BALL 1MJ6106-6CA CA-EXD % M 1MJ6 BALL 1MJ6113-8CB CA-EXD % L 1MJ6 BALL 1MJ6097-2CA CA-EXD % L 1MJ6 BALL 1MJ6106-4CA CA-EXD % M 1MJ6 BALL 1MJ6113-6CA CA-EXD % S 1MJ6 BALL 1MJ6130-8CB CA-EXD % L 1MJ6 BALL 1MJ6106-2CA CA-EXD % L 1MJ6 BALL 1MJ6107-4CA CA-EXD % S 1MJ6 BALL 1MJ6130-6CA CA-EXD % M 1MJ6 BALL 1MJ6133-8CB CA-EXD % M 1MJ6 BALL 1MJ6113-2CA CA-EXD % M 1MJ6 BALL 1MJ6113-4CA CA-EXD % M 1MJ6 BALL 1MJ6133-6CA CA-EXD % 85.0 Explosion Proof Weight (kg) M 1MJ6 BALL 1MJ6163-8CB CA-EXD % S 1MJ6 BALL 1MJ6130-2CA CA-EXD % S 1MJ6 BALL 1MJ6130-4CA CA-EXD % M 1MJ6 BALL 1MJ6134-6CA CA-EXD % M 1MJ6 BALL 1MJ6164-8CB CA-EXD % S 1MJ6 BALL 1MJ6131-2CA CA-EXD % M 1MJ6 BALL 1MJ6133-4CA CA-EXD % M 1MJ6 BALL 1MJ6163-6CA CA-EXD % L 1MJ6 BALL 1MJ6166-8CB CA-EXD % M 1MJ6 BALL 1MJ6163-2CA CA-EXD % M 1MJ6 BALL 1MJ6163-4CA CA-EXD % L 1MJ6 BALL 1MJ6166-6CA CA-EXD % L 1MJ6 BALL 1MJ6186-8CB CA-EXD % M 1MJ6 BALL 1MJ6164-2CA CA-EXD % L 1MJ6 BALL 1MJ6166-4CA CA-EXD % L 1MJ6 BALL 1MJ6186-6CA CA-EXD % L 1MJ6 BALL 1MJ6207-8CB CA-EXD % Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Low Voltage AC Selection and Pricing Guide Stock Model 7-25 Introduction General Purpose Duty Duty Purpose Dimensions

188 IEC - TEFCs 1MJ6 - Foot Mounted kw 50Hz kw 60Hz RPM rame Type DE Bearing Part Number List Price $ Mult. Symb. FL Amps 50Hz FL Nom. Eff. 50Hz Explosion Proof Weight (kg) L 1MJ6 BALL 1MJ6166-2CA CA-EXD % M 1MJ6 BALL 1MJ6183-4CA CA-EXD % L 1MJ6 BALL 1MJ6206-6CA CA-EXD % M 1MJ6 BALL 1MJ6183-2CA CA-EXD % L 1MJ6 BALL 1MJ6186-4CA CA-EXD % L 1MJ6 BALL 1MJ6207-6CA CA-EXD % L 1MJ6 BALL 1MJ6206-2CA CA-EXD % L 1MJ6 BALL 1MJ6207-4CA CA-EXD % L 1MJ6 BALL 1MJ6207-2CA CA-EXD % Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Stock Model Dimensions Introduction General Purpose Duty Purpose Duty Low Voltage AC Selection and Pricing Guide

189 IEC - TEFCs 1MJ7 - Foot Mounted kw 50Hz kw 60Hz RPM Frame Type DE Bearing Part Number List Price $ Mult. Symb. FL Amps 50Hz Explosion Proof FL Nom. Eff. 50Hz S 1MJ6 BALL 1MJ7220-8CB CA-EXD % M 1MJ7 BALL 1MJ7223-8CB CA-EXD % M 1MJ7 BALL 1MJ7223-6CA CA-EXD % M 1MJ7 BALL 1MJ7253-8CB CA-EXD % S 1MJ7 BALL 1MJ7220-4CA CA-EXD % M 1MJ7 BALL 1MJ7253-6CA CA-EXD % S 1MJ7 BALL 1MJ7280-8CB CA-EXD % M 1MJ7 BALL 1MJ7223-2CB CA-EXD % M 1MJ7 BALL 1MJ7223-4CA CA-EXD % S 1MJ7 BALL 1MJ7280-6CA CA-EXD % M 1MJ7 BALL 1MJ7283-8CB CA-EXD % M 1MJ7 BALL 1MJ7253-2CB CA-EXD % M 1MJ7 BALL 1MJ7253-4CA CA-EXD % M 1MJ7 BALL 1MJ7283-6CA CA-EXD % S 1MJ7 Roller (DE) 1MJ7310-8CB CA-EXD % S 1MJ7 BALL 1MJ7280-2CC CA-EXD % S 1MJ7 BALL 1MJ7280-4CA CA-EXD % S 1MJ7 Roller (DE) 1MJ7310-6CA CA-EXD % M 1MJ7 Roller (DE) 1MJ7313-8CB CA-EXD % M 1MJ7 BALL 1MJ7283-2CC CA-EXD % M 1MJ7 BALL 1MJ7283-4CA CA-EXD % M 1MJ7 Roller (DE) 1MJ7313-6CA CA-EXD % S 1MJ7 Roller (DE) 1MJ7310-2CC CA-EXD % S 1MJ7 Roller (DE) 1MJ7310-4CA CA-EXD % M 1MJ7 Roller (DE) 1MJ7313-2CC CA-EXD % M 1MJ7 Roller (DE) 1MJ7313-4CA CA-EXD % Prices and specifications are subject to change without notice Stock availability subject to sale FL Amps at 400V 50Hz Weight (kg) Stock Model Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 7-27 Dimensions

190 Introduction General Purpose Duty Duty Purpose Dimensions Options IEC Explosion Proof Description Code Pos. 1MJ6 1MJ7 Voltage 230VD / 400VY Hz - 460VY 60Hz 400VD / 690VY Hz - 460VD 60Hz See Additional Voltages Below Additional Voltages 440V D 60Hz L2R Z 460V D 60Hz L2T Z 575V D 60Hz L2V Z 220VD / 380VY 50Hz L1R Z 380VD / 660VY 50Hz L1L Z 425VD 50Hz L1D Z Feet & Flanges B3 Foot Monted - IMB3IMV5 / IMV6 (No canopy) B5 Flange - IMB5 IMV3 / IMV1 (No canopy) B14 Flange - IMB14 IMV19 / IMV18 (No canopy) B5 Flange - IMV1 with canopy B5 Flange with Feet - IMB35 (No canopy) B14 Flange with Feet - IMB34 (No canopy) Motor Protection 3 x PTC Thermistors Trippinig A11 Z x PTC Thermistors Alarm and Tripping A12 Z x PTC Thermistors Alarm, VFD A15 Z x PTC Thermistors Alarm and Tripping, VFD A16 Z Cooling Temperature & Insulation Increased air humidity/temperature C19 Z to 60 g per m3 of air THCL.F, acc. to B, Cooling Temp. 45ºC, C22 Z Power reduction 4% THCL.F, acc. to B, Cooling Temp. 50ºC, C23 Z Power reduction 8% THCL.F, acc. to B, Cooling Temp. 55ºC, C24 Z Power reduction 13% THCL.F, acc. to B, Cooling Temp. 60ºC, C25 Z Power reduction 18% Increased air humidity/temperature C26 Z to 100 g per m3 of air External earthing L13 Z Country Certification CCC China Compulsory Certification D01 Z (Only 1LA7 and 1LA9) China Ex-Zone 2 Certificate D32 Z Degree of Protection Degree of protection IP65 K50 Z Degree of protection IP56 K52 Z Heating & Ventilation Anti-condensation heating for 230V K45 Z Consult with factory for Zone 2 Anti-condensation heating for 115V K46 Z Consult with factory for Zone 2 Metal Fan K35 Z Prices and specifications are subject to change without notice Low Voltage AC Selection and Pricing Guide

191 Introduction General Purpose Duty Duty Purpose Consult Factory Standard Low Voltage AC Selection and Pricing Guide 7-29 Dimensions

192 Options IEC Explosion Proof Introduction Description Code Pos. 1MJ6 1MJ7 Connection Box Terminal Box on Right Hand Side (View from DE) K09 Z Terminal Box on Left Hand Side (View from DE) K10 Z Rotation of terminal box 90º(entry from DE) K83 Z Rotation of terminal box 90º (entry from NDE) K84 Z Cast Iron Terminal Box (Standard for 160L Frame) K15 Z Paint Special Paint Finish on RAL7030 K26 Z Primed Only K24 Z Special Paint Finish on RAL See Table Below 2) Y Bearings and Lubrication Bearing for increased cantilever forces K20 Z Regreasing device K40 Z Test Certificates & Auxiliary Nameplates Bearing for increased cantilever forces Y82 Z Regreasing device B02 Z Type test with heat run, Horizontal motors F83 Z Other Colors in RAL RAL Color Name RAL Color Name 1015 Light Ivory 5017 Traffic Blue 1019 Grey Beige 5018 Teal Blue 2003 Pastel Orange 5019 Capri Blue 2004 Pure Orange 6019 Patel Green 3007 Balck Red 7000 Squirrel 5007 Brilliant Blue 7004 Signal Grey 5009 Azure Blue 7011 Iron Grey 5010 Gentian Blue 7016 Anthracite Grey 5012 Light Blue 7022 Umber Grey 5015 Sky Blue 7033 Cement Grey Prices and specifications are subject to change without notice Dimensions General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide

193 Standard Standard Standard Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 7-31 Dimensions

194 Notes Dimensions Introduction Purpose Duty Duty General Purpose Low Voltage AC Selection and Pricing Guide

195 Introduction General Purpose Duty NEMA Motor Modifications Duty Purpose Low Voltage AC Selection and Pricing Guide 8-1 Dimensions

196 Introduction Siemens new program provides 'quick' deliveries for a wide selection of stock motor modifications from the Little Rock Modification Center. Definitions Delivery - 2 days* - Consists of a combination of 16 figures and letters structured to describe the characteristics of the NEMA motor for order entry. Please refer to Section 9 for the complete part numbering system. Example: 1LE21012AB214AA3 - GP10A, 10HP, 1800RPM, /460V, 215T, horizontal foot-mounted Positioning L E A B A A 3 Order Code - Figures or letters describing the or Option. Order Code Position - The position within the that the or Option Order Code would be added. Ordering Instructions 1. Select stock motor from Sections 2 thru 4. (Note ) 2. Verify applicability of desired (s). (Per motor type & frame on pages 5-4 to 5-7) 3. Select applicable (s). (Note Order Code, Order Code Position and List Price Adder from pages 5-4 to 5-7) 4. Construct new and List Price. (See examples) a. If the Order Code Position is 12, 13, 14, 15 or 16, replace the figure(s) or letter(s) at the same position in the stock motor with the Order Code. b. If the Order Code Position is Z, add a '-Z' to the end of the stock motor. Then add a '+' sign followed by the Order Code. plus Options (See Section 6) - Available as custom built motors only. Please contact Siemens for delivery time. See example on page 6-1. * Working days, calculated from normal business hours excluding holidays and weekends, not including the day the purchase order is received. Subject to availability of the stock motors and parts at the time of order entry. Maximum 3 s per motor. Dimensions General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide

197 Motor Pricing Examples Example #1: 10HP, 1800RPM, /460V, 215T, GP10A, D-flange with feet, normally closed thermostats and bi-directional rotation arrow. Introduction General Purpose Base List Price: $649 1LE21012AB214AA3 List Price Adders: D-Flange with Feet $273 Order Code F, Order Code Position 14 Thermostats $150 Order Code G, Order Code Position 15 Rotation Arrow $95 Order Code K70, Order Code Position Z Total List Price: $1,167 New - 1LE21012AB214FG3-Z +K70 Delivery: 2 Working Days, subject to availability Duty Example #2: 75HP, 1800RPM, 460V, 365T, RGZESD, horizontal foot mounted with C-face and 115 volt space heaters. Base List Price: $6,305 1LE29513CB212AA3 List Price Adders: C-Face $703 Order Code E, Order Code Position 14 Space Heaters $351 Order Code A40, Order Code Position Z Total List Price: $7,359 New - 1LE29513CB212EA3-Z +A40 Delivery: 2 Working Days, subject to availability Duty Purpose Low Voltage AC Selection and Pricing Guide 8-3 Dimensions

198 Introduction General Purpose Duty Duty Purpose Dimensions Overview Description Code Order Code Pos GP10A GP100A GP10 GP100 RGZP Low Voltage AC Selection and Pricing Guide Motor Type / Frame Applicability SD10 RGZESD RGZEESD RGZEESDX Altitude / Ambient Rerate/Derate Y80 Z S S S S S449 Assembly - Mounting & Terminal Box Position F F W-1 9+R1A 16+Z W-2 9+R2A 16+Z S S S S S449 W-3 9+R3A 16+Z S S S S S449 W-4 9+R4A 16+Z W W S S S S S449 C C S S S S S449 Bearings Sealed Ball bearings 1 (except 2 pole, 360+ frames) L68 Z S S S Breathers and Drain Plugs T Drain SS L45 Z S S S S S449 Crouse Hinds - UL L46 Z S S S S S449 Approved Conduit Box - Main Orient 90 deg CCW J84 Z S S S S S449 Orient 180 deg CCW J85 Z S S S S S449 Orient 270 deg CCW J86 Z S S S S S449 Conduit Box - Auxiliary for Thermostats Condulet to Main Box J12 Z S S S S S449 Conduit Box - Auxiliary for Space Heaters Condulet to Main Box J52 Z S S S S S449 Drip Cover Drip cover without K33 Z S S S S S449 vertical lifting devices Export Packaging Sea Freight - Siemens B09 Z S S S S S449 Standard Flanged End Shields C-Face with Feet 2 E C-Face without Feet G D-Flange with Feet F Grounding Provision (tapped hole L27 Z S S S S S449 on frame w/bolt) Hardware Stainless Steel L22 Z S S S S S449 Lifting Eyebolt 3 L20 Z Standard 140 Standard 140 Standard Standard Standard Standard Duty Group D, F&G, 1.15SF M80 Z (Rerate) Insulation Fungus Protection C07 Z S S S S S449 Leads / Terminal Blocks Burndy Hydent type YA K80 Z S S S S S449 Sealed Leads K89 Z Sealed Ball bearings not available for 2 pole motors with frames > C face with feet for 440 frames, only available with ball bearings 3 Lifting eyebolt is provided as standard except where indicated for 140 Frames

199 RGZZESD RGZZESD 1D1 RGZESDI RGZZESDI RGZV -ESD -ILESD RGZZV -ESD -ILESD List Price Adder Per Frame ($) S449 Introduction General Purpose S S S S S S Duty Duty S S S S S S S S S Purpose S S Standard Standard 30 std std std std std std std std std std S S Standard Standard Standard Standard Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required Low Voltage AC Selection and Pricing Guide 8-5 Dimensions

200 Introduction General Purpose Duty Duty Purpose Dimensions Overview Description Code Order Code Pos Motor Type / Frame Applicability GP10A GP100A GP10 GP100 RGZP SD10 RGZESD RGZEESD RGZEESDX Lubrication Grease Fitting / Pressure L60 Z S S S449 Standard Standard Relief Nameplate Extra M21 Z S S S S S449 Division 2 4 M22 Z S S S S S449 Change (Rerate/Derate) Y80 Z S S S S S449 Auxiliary Y82 Z S S S S S449 Protective Devices - Windings Thermostats, normally G S S S S S449 closed, 2 per motor Rotation Arrow Bidirectional (not K70 Z S S S S S449 applicable for unidirectional motors) Clockwise (facing ODE) K71 Z S S S S S449 Counterclockwise K72 Z S S S S S449 (facing ODE) Service Factor Rerate/Derate Y80 Z S S S S S449 Shaft Seal Slinger & O Ring (4, 6, 8 L76 Z S S S S449 Pole only) Inpro Seal / DE L79 Z S S S Inpro Seal / ODE L80 Z S Inpro Seal / Both Ends L81 Z S449 Standard Standard Software Documentation in D05 Z S S S S S449 Spanish Certificate of Compliance F00 Z S S S S S449 Standard F40 Z S S S S S449 Transmittal Standard Dimension F42 Z S S S S S449 Sheet Conduit Box Dimension F44 Z S S S S S449 Sheet Wiring Diagram F45 Z S S S S S449 IOM F46 Z S S S S S449 Renewal Parts F47 Z S S S S S449 Sheets F49 Z S S S S S449 F03 Z S S S S S449 Space Heater 115V, Single Phase A40 Z S S S S S V, Single Phase A41 Z S S S S S V, Single Phase, Div 2 A42 Z S S S S S V, Single Phase, Div 2 A44 Z S S S S S449 Testing Routine Test Report F10 Z S S S Routine Test Report with F20 Z S S S S S449 Vibration Test Voltage Single Voltage & HP 75HP HP V (outside leads connection only) Single Voltage - 460V (outside leads connection only) 12 12& HP 75HP HP Sealed Ball bearings not available for 2 pole motors with frames > C face with feet for 440 frames, only available with ball bearings Low Voltage AC Selection and Pricing Guide 3 Lifting eyebolt is provided as standard except where indicated for 140 Frames

201 RGZZESD RGZZESD 1D1 RGZESDI RGZZESDI RGZV -ESD -ILESD RGZZV -ESD -ILESD List Price Adder Per Frame ($) S449 Introduction General Purpose S S S S S Standard S449 Standard Standard Duty S S S Duty S S S S S S S S S S S S S S S S S S Purpose 20HP HP 20HP HP HP 20HP Surface temperature of space heaters will be shown on external surface of motor. CSA certification; Class, Division and T Code required with order. ASD operation, Type RGZESDI is required Low Voltage AC Selection and Pricing Guide 8-7 Dimensions

202 Introduction General Purpose Duty s ALTITUDE TEFC (General Purpose & ) motors with a 1.15 service factor in a 40 C ambient at 3300 feet will operate at a 1.0 service factor in a 40 C ambient at altitudes up to 9900 feet. For altitudes greater than 9900 feet, please consult Siemens. Standard motors will operate at their rated service factor at altitudes above 3300 feet at the corresponding ambient temperatures as shown in the following table. AMBIENT TEFC (General Purpose & ) motors with a 1.15 service factor in a 40 C ambient at 3300 feet will operate at a 1.0 service factor at 3300 feet altitude up to a 65 C ambient. For ambients greater than 65 C or below -25 C, please consult Siemens. Maximum Altitude Feet Ambient Temperature (ºC) Duty Purpose ASSEMBLY - Mounting & Terminal Box Position can be furnished in assemblies shown. Modifications will be of F-1 assembly stock motors. When motors are ordered according to a particular mounting, bearing brackets are assembled and grease fittings are properly installed for operation with the motor in the position shown. However, no attempt is made to locate fittings on any particular side of the motor. CAUTION: ** Horizontal ball bearing motors assembly W-5, W-6, W-7 and W-8 are not suitable for external thrust in excess of the weight of the rotor and half-coupling. CONDUIT BOX - AUXILIARY Condulet to Main Box Dimensions HARDWARE Stainless steel hardware, limited to bearing housing bolts, terminal housing bolts, and breather drains only. HAZARDOUS DUTY - RERATE Motor type RGZZESD (Class I, Group D, Class II, Groups F & G, Division 1) with 1.0 service factor can be re-nameplated to RGZZESD (Class I, Group D, Division 1) with 1.15 service factor for frame motors only. NAMEPLATES Division 2 Non hazardous duty motors can be used in Class I and Class II Division 2 areas provided no arcing devices are used. Advise ignition temperature or T-code and Class with requests. ODP motors not available for application in Division 1 or Division 2 areas. Non (agency) certified, general purpose and severe duty motors are available with the following metal tag: Low Voltage AC Selection and Pricing Guide MOTOR MEETS, DURING NORMAL OPERATION, THE DEFINITION IN THE NATIONAL ELECTRICAL CODE (B) FOR MOTORS PERMITTED TO BE INSTALLED IN CLASS I, DIVISION 2 AREAS. NATIONAL ELECTRICAL CODE REQUIREMENTS AND RESTRICTIONS MUST BE OBSERVED

203 s Frequency Change The following tabulation shows the synchronous speeds for 60 and 50 hertz. For different frequencies or adjustable frequency applications, contact Siemens. To derate a continuous duty 60 hertz motor to a continuous 50 hertz motor, use the modifiable list price of the next larger HP 60 hertz motor and add the list price as shown in the table. Motor will be Class F, 1.15 service factor. Speed (RPM) No. of Poles 60 Hertz 50 Hertz Introduction General Purpose SERVICE FACTOR For non-standard service factor, contact Siemens. Refer to Duty for rerating RGZZESD motors from the standard 1.0 service factor to a 1.15 service factor. SPACE HEATERS Leads marked H1 & H2 List price addition covers space heaters installed in motors with leads terminated in the main conduit box. NEC (2005) requires any Division 2 motor that is not agency certified and is a general purpose non-explosion enclosure to permanently mark on a visible nameplate on the motor surface the max surface temp based on 40 C ambient - this plate will show 200 C. CAUTION: Use in Division 2 areas with iginition temperatures below 250 C (250 x.80 = 200) should be avoided. [Reference: 501-8(b)]. SOFTWARE D05 Documentation in Spanish Duty Duty Purpose F00 F40 F42 F44 F45 F46 F47 F49 Certificate of Compliance, Copy of original customer P.O. must accompany order Standard Transmittal and certification sheet, including motor description and nameplate data Standard Tabulated Dimension Sheet Standard Conduit Box Dimension Sheet Standard wiring/coonection diagram Standard operation and maintanence bulletins Standard renewal parts bulletin for standard construction Standard Tabulation performance data sheets with typical data; only 460V 60HZ F03 TESTING All Siemens motors are given a routine line test per NEMA MG1 and IEEE-112. Vibration data is NOT recorded with a routine test. If required, please add. Test report of routine test is based on IEEE Std. 112 Form A-1 and includes complete nameplate information. Standard curves, single page format includes curves of speed vs. torque, amps, horspower vs power factor, efficiency, amps, speed; based on typical data ROUTINE TEST Routine test consists of the following items tested in accordance with IEEE standard 112. No Load Current No Load Speed Locked-Rotor Current Winding Resistance High Potential Bearings/Vibration Check Low Voltage AC Selection and Pricing Guide 8-9 Dimensions

204 Introduction General Purpose Duty Duty Purpose Accessories BASES SLIDE BASS - Shippped loose Base Description Frame List Price Adder $ Lead Time (Days) Single Adjustment Slide CP T 83 5 CP T 83 5 CP T 83 5 CP T 83 5 CP T 93 5 CP T 93 5 Double Adjustment Slide CP T CP T CP t CP T CP T CP T CP T CP T CP T CP T CP T CP T CP T CP T Dimensions ADAPTER BASES (RG Only) - Shipped loose Old Frame Base Adapter New Frame List Price Adder $ CP U-184U 143T-145T CP U-215U 182T-184T CP U-256U 213T-215T CP U-286U 254T-256T CP S 284TS CP S-326S 284-TS-286TS CP U-326U 284T-286T CP U-365U 324T-326T CP US-365US 324TS CP US 326TS CP U-405U 364T-365T CP US-405US 364TS-365TS CP U-445U 364T-365T CP U-445U 404T-405T CP US-445US 364T-365T CP US-445US 364TS-365TS CP US-445US 404TS-405TS * If special adapter base is required, refer to Factory for price and shipment Lead Time (Days) Low Voltage AC Selection and Pricing Guide

205 Options All Options selected from this section will require a custom built motor. Please contact Siemens for delivery time. Introduction General Purpose Definitions: See Page 5-2. Ordering Instructions: 1. Select stock motor from Sections 2 thru 4. (Note ) 2. Verify applicability of desired Option(s). (Per motor type & frame on pages 6-2 to 6-9) 3. Select applicable Options(s). (Note Order Code, Order Code Position and List Price Adder from pages 6-2 to 6-9) 4. Construct new and List Price. (See examples) a. If the Option Order Code Position is 12, 13, 14, 15 or 16, replace the figure(s) or letter(s) at the same position in the stock motor with the Option Order Code. b. If the Option Order Code Position is Z, add a '-Z' to the end of the stock motor. Then add a '+' sign followed by the Option Order Code. Duty Duty Options can be combined with s from Section 5. Please contact Siemens for delivery time. See Example below. Options combined with Motor Pricing Example: Purpose 15HP, 1800RPM, /460V, 254T,, D-flange with feet, PTC thermistors (3 embedded temperature sensors for tripping) with condulet to main box and Class H insulation. Base List Price: $1,440 1LE23112BB114AA3 List Price Adders: D-Flange with Feet $534 Order Code F, Order Code Position 14 ( from Section 5) PTC Thermistors $150 Order Code B, Order Code Position 15 Condulet to Main Box $165 Order Code J02, Order Code Position Z Class H Insulation $105 Order Code C00, Order Code Position Z Total List Price: $2,394 New - 1LE23112BB114FB3-Z +J02 +C00 Delivery: Please contact Siemens for delivery Low Voltage AC Selection and Pricing Guide 9-1 Dimensions

206 Introduction General Purpose Duty Duty Purpose Dimensions Options Overview Description Code Order Code Pos Low Voltage AC Selection and Pricing Guide GP10A GP100A Motor Type / Frame Applicability GP10 GP100 SD10 Assembly - Mounting & Terminal Box Position W S S449 W F S449 S449 Auxiliary boxes 1 Auxiliary conduit box location (Digit 2) Condulet on main box side J 0 Z S S449 Condulet to main conduit box J 2 Z S S449 Auxiliary conduit box to main conduit box J 3 Z S S449 Condulet - opposite of main conduit box side J 4 Z S S449 Auxiliary box - opposite of main conduit box side J 5 Z S S449 XP condulet - opposite of main conduit box side J 6 Z Temperature detector device (Digit 1) Select the number that corresponds with the appropriate Temperature DetectorDevice to create your initial 3 digital ordering code. Thermistors 0 Thermostats 1 KTY 84 Thermistor 2 Space heaters 5 Stator RTD s to auxiliary conduit box J S S449 of opposite of main box side Balance Precision M69 Z S449 Standard Extra Precision M70 Z S S449 Bearings Roller Instead of Ball L65 Z Insulated L66 Z S449 - Insulated - ODE only L67 Z S449 - Couplings er Supplied H10 Z S S449 Encoder - Single Output - TEFC Avtron M PPR G00 Z Avtron M PPR G01 Z Avtron M PPR G02 Z Avtron M PPR G03 Z BEI HS PPR G04 Z Dynapar HS PPR G05 Z Northstar PPR ( ) G06 Z Northstar PPR ( ) G07 Z Northstar SL PPR G08 Z Avtron HS35A G09 Z Encoder - Special Special Y75 Z Export Packaging Sea Freight - Siemens Standard B09 Z Special B10 Z S S449 Fans Bronze M10 Z S S449 Duty Group C&D, 1.15SF M81 Z Group C&D, F&G, 1.0SF Only M82 Z Insulation Class H C00 Z S S449 Vacuum Pressure Impregnation (VPI) C01 Z S S449 Moisture/Powerhouse (extra dip & bake) C04 Z S S449 Tropicalization Moisture (extra dip & bake, fungus spray) C08 Z S S449 1 Condulet or Auxiliary box to Main only available for GP motors when ordered with Cast Iron Terminal Box For availability on Flanges and End shields as Options see page 9-14

207 RGZZESD RGZZESD 1D1 RGZESDI RGZZESDI RGZV -ESD -ILESD List Price Adder Per Frame ($) S449 Introduction General Purpose S S Duty S S std std std S S S S S S S S cf cf cf cf cf cf cf cf cf cf cf S cf cf cf cf cf cf cf cf cf cf cf S S S S S Low Voltage AC Selection and Pricing Guide 9-3 Duty Purpose Dimensions

208 Introduction General Purpose Duty Duty Purpose Options Overview Description Code Order Code Pos GP10A GP100A Motor Type / Frame Applicability GP10 GP100 SD10 Leads / Terminal Blocks Terminal Block - 3 lead only K83 Z Leads, Special Cable Length Y85 Z S S449 Lubrication Special Grease (High & Low Temp) (Mobil 28) L57 Z S S449 Special Grease (Mobilith SHC 100) L58 Z S S449 Paint Paint - 3 Part Epoxy (Carboline or Ameron) N01 Z S S449 Paint - 2 Part Epoxy N02 Z S S449 Standard Primer Only N03 Z S S449 Standard Paint, Special Color Y60 Z S S449 Special Paint, Special Color Y61 Z S S449 Protective Devices - Windings PTC thermistors, 3 embedded temperature B S S449 sensors for tripping PTC thermistors, 6 embedded temperature C S S449 sensors for alarm and tripping KTY84-130, 2 embedded temperature sensors F S S449 Thermocouples, coil head J S S449 Winding temperature protection, Stator RTD's (coil head, K S S449 1 per phase), 100Ω Platinum, complete with auxiliary box with terminal strip opposite to main box Protective Devices - Bearings Bearing thermal protection, Bearing RTDs with connection A51 Z S S449 head and terminal block - both ends, 100Ω Platinum Shafts Carbon Steel (C4140) M57 Z S S449 Shaft DE Special to er Specifications Y50 Z S S449 Shaft ODE Special to er Specifications Y51 Z S S449 NEMA Standard Short Shaft - ODE M53 Z S S449 NEMA Standard Long Shaft - ODE M52 Z S S449 Shaft Grounding Brush Shaft Grounding Brush L29 Z Shaft Seal Brass Seal L84 Z Software Nonstandard Dimension Sheet F43 Z S S449 er Specific Sheets F50 Z S S449 Special Calculated F07 Z S S449 1 Condulet or Auxiliary box to Main only available for GP motors when ordered with Cast Iron Terminal Box Dimensions Low Voltage AC Selection and Pricing Guide

209 RGZZESD RGZZESD 1D1 RGZESDI RGZZESDI RGZV -ESD -ILESD List Price Adder Per Frame ($) S449 Introduction General Purpose S cf cf cf cf cf cf cf cf cf cf cf S S S S S S S cf cf cf cf cf cf cf cf cf cf cf S S S S S Duty Duty Purpose S S cf cf cf cf cf cf cf cf cf cf cf S cf cf cf cf cf cf cf cf cf cf cf S S S S S S Low Voltage AC Selection and Pricing Guide 9-5 Dimensions

210 Introduction General Purpose Duty Duty Options Overview Description Code Order Code Pos GP10A GP100A Motor Type / Frame Applicability GP10 GP100 SD10 Space Heater 115V, Single Phase, Ex. Proof A43 Z Terminal Box - Main Cast Iron Instead of Cast Aluminum or Steel L01 Z Testing Routine Test Report - (Witnessed) F12 Z S449 - Complete Test F15 Z S S449 Complete Test (Witnessed) F17 Z S S449 Calibration Test F27 Z S S449 Electrical Duplicate - (Routine Test) F36 Z S S449 Electrical Duplicate (Complete Test) F37 Z S S449 Noise F30 Z S S449 Noise (Witnessed) F32 Z S S449 Routine Test Report with Vibration Test (Witnessed) F22 Z S S449 Vertical Jacking Vertical Jacking Provision M39 Z S S449 Vibration Detectors Vibraswitch Robert Shaw malfunction detector Model A66 Z S S D8 120VAC Provision for vibration sensors (PMC/Beta) on A67 Z S S449 D.E. & O.D.E Voltage Special Voltage V M1Y 12,13+Z S S449 Special Voltage V M2Y 12,13+Z S S449 Part Winding Start - 200V, 60Hz 20 12& Part Winding Start - 230V, 60Hz 21 12& Part Winding Start - 460V, 60Hz 22 12& S S449 Part Winding Start - 575V, 60Hz 23 12& S S449 Wye Start - Delta Run - 200V, 60Hz 30 12& Wye Start - Delta Run - 230V, 60Hz 31 12& Wye Start - Delta Run - 460V, 60Hz 32 12& S S449 Wye Start - Delta Run - 575V, 60Hz 33 12& S S449 1 Condulet or Auxiliary box to Main only available for GP motors when ordered with Cast Iron Terminal Box Dimensions Purpose Low Voltage AC Selection and Pricing Guide

211 RGZZESD RGZZESD 1D1 RGZESDI RGZZESDI RGZV -ESD -ILESD List Price Adder Per Frame ($) S449 Introduction General Purpose S S S S S S S S S S S S S S S S S S Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 9-7 Dimensions

212 Introduction General Purpose Duty Duty Purpose Options s BALANCE All motors are dynamically balanced to commercial limits measure in accordance with NEMA MG Modified motors can be built to exceed standard commercial limits based on Table 1 below. BALANCE LIMITS MAXIMUM AMPLITUDE, INCHES, PEAK TO PEAK NEMA Balance Standard Precision Extra Precision RPM 143T 143T 364T 143T 284T 364T 449T 326T 449T 256T 326T 449T mils P/P mils P/P mils P/P VELOCITY, INCHES INCHES/SECOND Balance NEMA Standard Precision Extra Precision RPM 143T 143T 364T 143T 284T 364T 449T 326T 449T 256T 326T 449T in/sec in/sec in/sec NOTE: IN P-P refers to amplitude displacement. NEMA unfiltered velocity limit 0.15 in/s peak. IEEE Std 841 unfiltered velocity limit 0.08 in/s peak. NOTE: For balance limits greater than Precision balance, contact factory. BEARINGS Insulated bearings are only available as sealed bearings. having roller bearings (444T to 449T) require a minimum radial load. Use of these motors in direct connected applications is discouraged to avoid excessive drive end bearing noise and/or reduced bearing life. Dimensions Low Voltage AC Selection and Pricing Guide

213 Options s AUXILIARY BOXES Condulet - On Main Box side Condulet to Main Box Auxiliary Box to Main Box Condulet - Opposite of Main Box Auxiliary Box- Opposite of Main Box Explosion Proof Condulet - Opposite of Main Box PTC Thermistors J00 J02 J03 J04 J05 J06 Thermostats J10 J12 J13 J14 J15 J16 KTY84 Temperature Sensors J20 J22 J23 J24 J25 J26 Space Heaters J50 J52 J53 J54 J55 J56 Introduction General Purpose Duty Duty Purpose CONNECTIONS Part Winding Start - Starting torques are reduced at the motor shaft. Wye Start - Delta Run - Starting torques are reduced at the motor shaft. Standard 50 hertz voltages are 220, 380, 400, 415, 440, 550 and 220/380. Standard 60 hertz voltages are 200, 230, 460, 575 and 230/460. COUPLINGS - er Supplied Rigid couplings, flexible couplings, pinions and V-belt sheaves can be pressed on at List Price adders per the table below. Couplings, pinions or sheaves must be finish bored and key seated to Siemens shaft dimensions and must be shipped to the plant freight prepaid Low Voltage AC Selection and Pricing Guide 9-9 Dimensions

214 Introduction General Purpose Options s ENCODERS Encoder Selection Guide Encoders (also known as tachometers) mount on the motor shaft to provide precise speed and position feedback to the control system. Encoders use two basic technologies: Magnetic/Magneto resistive, and Optical; and two common mounting methods: hollow shaft and modular. Encoder selection should be based on several factors: mechanical service duty, and environment. Duty Duty Purpose Type of Encoder Optical encoders are usually less expensive, but are more vulnerable to shock, vibration, and contamination from dusty, dirty, wet or chemical environments; Siemens recommends magnetic encoders for these environments. Encoder Mounting Hollow shaft / tethered encoders are easier to mount, but are less robust than modular encoders; Siemens recommends modular encoders for rough mechanical service applications. Other mountings technologies, such as solid shaft coupled, are available and may be required for special applications, but are not generally recommended. Call factory for pricing. Encoder Wiring: Encoders may be connected via military connectors (solder connections with screw housing) or industrial connectors (pin connections with terminal strip) Vendor standard connectors shown; call factory for special connectors. Applications Recommended Type Conveying Converting Films Paper Steel Hoist Marine Oil Drilling Light Standard Heavy Darker = Better suited for application. Order Codes Accessory Single Output Dual Output Marker Pulse Shaft Grounding Avtron M PPR G00 Y75 Std Y75 Avtron M PPR G01 Y75 Std Y75 Avtron M PPR G02 Y75 Std Y75 Avtron M PPR G03 Y75 Std Y75 BEI HS PPR G04 NA Std Y75 Dynapar HS PPR G05 NA Std Y75 Northstar PPR ( ) G06 Y75 Y75 Y75 Northstar PPR ( ) G07 Y75 Y75 Y75 Northstar SL PPR G08 Y75 Y75 Y75 Avtron HS35A G09 NA Std Y75 Dimensions Low Voltage AC Selection and Pricing Guide

215 Options s Encoders can be factory installed at Siemens for RGZESDI and RGZZSDI motors only. Unless specified, all encoders have 1024PPR; other PPR & special voltage output ranges available upon request. Introduction General Purpose NEMA Frame Model Mill Duty Encoder Style List Price Adder $ Optional List Price Adder $ Connector Single Dual Marker Shaft Style Output Output Pulse Grounding Output (VDC) Totally Enclosed Fan Cooled Avtron M3 Standard Optical Hollow Shaft Std 420 Industrial 5-24 E Avtron M56 Heavy Magnetic Modular Std cf Industrial 5-24 C Avtonr HS35A Light Optical Hollow Shaft 875 NA Std cf Military 5-24 E BEI HS35 Light Optical Hollow Shaft 1246 NA Std cf Military 5-24 E Dynapar HS35 Light Optical Hollow Shaft 900 NA Std cf Military 5-24 E Northstar SL56 Heavy Magnetic Modular cf Industrial 5-15 C Avtron M3 Standard Optical Hollow Shaft Std 420 Industrial 5-24 E Avtron M85 Heavy Magnetic Modular Std cf Industrial 5-24 C Avtonr HS35A Light Optical Hollow Shaft 875 NA Std cf Military 5-24 E BEI HS35 Light Optical Hollow Shaft 1246 NA Std cf Military 5-24 E Dynapar HS35 Light Optical Hollow Shaft 900 NA Std cf Military 5-24 E Northstar 8500 Heavy Magnetic Modular Industrial 5-15 F Avtron M4 Heavy Magnetic hollow Shaft Std 458 Industrial 5-24 E Avtron M85 Heavy Magnetic Modular Std cf Industrial 5-24 C 400-S449 BEI HS35 Light Optical Hollow Shaft 1246 NA Std cf Military 5-24 E Dynapar HS35 Light Optical Hollow Shaft 900 NA Std cf Military 5-24 E Northstar 8500 Heavy Magnetic Modular Industrial 5-15 D Figure Duty Duty Purpose NEMA Frame Model Mill Duty Encoder Style List Price Adder $ Optional List Price Adder $ Connector Single Dual Marker Shaft Style Output Output Pulse Grounding Output (VDC) Totally Enclosed Blower Cooled Avtron M4 Heavy Magnetic hollow Shaft Std 420 Industrial 5-24 B Avtron M56 Heavy Magnetic Modular Std cf Industrial 5-24 B Avtonr HS35A Light Optical Hollow Shaft 1245 NA Std cf Military 5-24 B BEI HS35 Light Optical Hollow Shaft 1616 NA Std cf Military 5-24 B Dynapar HS35 Light Optical Hollow Shaft 1270 NA Std cf Military 5-24 B Northstar SL56 Heavy Magnetic Modular cf Industrial 5-15 B Avtron M4 Heavy Magnetic hollow Shaft Std 458 Industrial 5-24 B Avtron M85 Heavy Magnetic Modular Std cf Industrial 5-24 B BEI HS35 Light Optical Hollow Shaft 1616 NA Std cf Military 5-24 B Northstar 8500 Heavy Magnetic Modular Industrial 5-15 B Dynapar HS35 Light Optical Hollow Shaft 1270 NA Std cf Military 5-24 B Avtonr HS35A Light Optical Hollow Shaft 1245 NA Std cf Military 5-24 B Northstar SL56 Heavy Magnetic Modular cf Industrial 5-15 B Avtron M4 Heavy Magnetic hollow Shaft Std 458 Industrial 5-24 B Avtron M85 Heavy Magnetic Modular Std cf Industrial 5-24 B 400-S449 Northstar 8500 Heavy Magnetic Modular Industrial 5-15 B Figure Low Voltage AC Selection and Pricing Guide 9-11 Dimensions

216 Introduction General Purpose Duty Options s HAZARDOUS DUTY MOTORS Class I: Gr. B Gr. C Gr. D Class II: Gr. E Gr. F Gr. G Hydrogen (not available). Atmospheres containing ethyl and ether vapor. Atmospheres containing gasoline, petroleum, naphtha, alcohols, acetone lacquer solvent vapors and natural gas. Atmospheres containing metal dust. Atmospheres containing carbon black, coal or coke dust. Atmospheres containing grain dust. Motor type RGZZESD (Class I, Groups C & D, Division 1) with 1.0 service factor can be rerated to RGZZESD (Class I, Groups C & D, Division 1) with 1.15 service factor for frame motors only. Duty Motor type RGZZESD (Class I, Groups C & D, Division 1) with 1.0 service factor can be rerated to RGZZESD (Class I, Groups C & D, Class II, Groups F & G, Division 1) with 1.0 service factor. LUBRICATION Purpose Provisions for Oil Mist - Convert a motor built with grease lubricated bearings to one that can be converted to oil-mist lubricated bearings at a future date. Siemens does not supply the oil mist system, reclassified orifice, details of flow rate or oil-air ratios. Such information must be obtained from the oil-mist vendor. Oil Mist Ready - Convert a motor built with grease lubricated bearings to oil mist lubricated bearings for immediate use. Siemens does not supply the oil mist system, reclassified orifice, details of flow rate or oil-air ratios. Such information must be obtained from the oil-mist vendor. PAINT Siemens standard finish paint consists of the following: Epoxy modified acrylic air dry enamel. Viscosity: seconds No.2 Zahn 77 F Fineness: 7 N.S. units Hegeman gage Adhesion: 90% Cross-hatch test (tape) Impact resistance: 40 inch pounds direct - No cracks Composition: Lead and Chromate free Color: RAL 7030 stone gray PROTECTIVE DEVICES WINDING PROTECTION Control Modules are available for thermistors. Order Code A90. Add $450 List. Shipped loose for customer installation. Price does not include temperature readout devices. Contact factory for other resistance values. Thermistors - leads marked PM1 & PM2 BEARING PROTECTION Price does not include temperature readout devices. Contact factory for other resistance values. Dimensions Low Voltage AC Selection and Pricing Guide

217 Options s SHAFTS Standard dimensions are shown in the Dimensions section. The following opposite drive end standard double-end shafts are available as custom built motors. Shaft dimensions not shown should be referred to your Siemens Representative for quotation. Double-End Shafts, Standard Steel - Drive End Standard - Opposite Drive End as Follows Order Code - M53 NEMA Standard Short Shaft Order Code - M52 NEMA Standard Long Shaft Frame FU Key FN-FW FV Key Length FN-FW FV Key Length T T T T T T T T T Introduction General Purpose Duty Duty TESTING COMPLETE TEST Complete test consists of the following items tested in accordance with NEMA and IEEE-112 test standards. Full Load Heat Run Temperature Rise at F.L. Winding Resistance Rated F.L. Slip No Load Current Breakdown Torque Locked Rotor Torque-Amps High Potential Tests 100, 75, 50 Percent Load Power 100, 75, 50 Percent Load Test report of complete test is based on IEEE Std. Form A-2 and includes complete nameplate information. CALIBRATION TESTS Calibration test consists of 0-125% rated load test measurement of speed, torque, current, power factor and efficiency, at rated voltage. is curve rated voltage. is curve plotted, on Siemens standard format. Foot mounted motors only. SPECIAL TESTS For tests or reporting format other than those listed below, contact Siemens with complete specification, for price additions. ers will be notified approximately 2 weeks before witnessed testing. Refer to Siemens for prices of test reports for adjustable speed drives. Multispeed motor test reports are priced based upon the number of speeds tested. List prices are at the following percentage of the single speed price: One speed tested 100% Two speeds tested 150% Pricing: Five copies of each test report are provided on 8.5" x 11" paper suitable for reproduction. Additional copies are available for $35 List per copy. Purpose VERTICAL JACKING PROVISIONS This option is provided on foot mounted motors only. It is used to assist the installer in proper alignment of the motor shaft with the driven piece of equipment for shimming purposes. Siemens will provide the tapped hole (one per foot), four per motor. A 1/2-13 UNC threaded hole will be provided on 280T frame, a 3/4-10 UNC threaded hole on 320T-360T and a 7/8-14 UNF threaded hole on 400T-440T frames. The customer is responsible for providing the bolts Low Voltage AC Selection and Pricing Guide 9-13 Dimensions

218 Notes Dimensions Introduction Purpose Duty Duty General Purpose Low Voltage AC Selection and Pricing Guide

219 Technical Notes HP x.746 = kw kw x = HP Torque (lb. - ft.) = HP x 520 RPM HP = Torque (lb. - ft.) X RPM 5250 WK2 (Inertia - Lb. Ft.2) at Motor Shaft = (Load RPM Mtr. F.L. RPM)2 x Load WK 2 Inertia (Kilogram - meter 2 ): kgm 2 x = lb. ft. 2 (lb. ft = kgm 2 ) (lb. ft. 2 x.042 = kgm 2 ) GD2 (kgfm 2 ) x = lb. ft 2 kgfm 2 4 = kgm 2 Torque (Newton - meters): Power (Kilowatts): Nm x.7376 = lb. - ft. (lb. ft. x = Nm) kw x = HP (HP = kw) (HP x.746 = kw) Temperature: Deg C = 5/9 ( F - 32) F = (9/5 x C) + 32 Notes: To find amperes at various voltages: 575 V = 460 V Amperes x V = 460 V Amperes x V = 460 V Amperes x 2.3 (Amperes = Full Load, Locked Rotor and No Load Values - from data pages) All other data (kva Code, Efficiencies, Power Factors, Torques and Stall Times) remain same as 460 V (winding connections can change - rarely - with voltage designs). When NEMA Nominal F.L. Efficiency is Then Minimum F.L. Efficiency is Introduction General Purpose Duty Duty Purpose General Capabilities For Use With Adjustable Speed Drives Product Line Efficiency Voltage Frame Size Variable Torque Constant Torque GP10A High / T 256T 3 Hz 60 Hz 15 Hz 60 Hz GP10 High / T 256T 3 Hz 60 Hz 15 Hz 60 Hz SD10 High / T 256T 3 Hz 60 Hz 15 Hz 60 Hz GP100A NEMA Premium / T 256T 3 Hz 60 Hz 15 Hz 60 Hz GP100 NEMA Premium / T 256T 3 Hz 60 Hz 15 Hz 60 Hz NEMA Premium / T 256T 3 Hz 60 Hz 15 Hz 60 Hz 230/460 & T 449T NEMA Premium T 449T 3 Hz 60 Hz 15 Hz 60 Hz GP100A Exceeds NEMA / T 256T 3 Hz 60 Hz 6 Hz 60 Hz Premium (Cu rotor) GP100 Exceeds NEMA / T 256T 3 Hz 60 Hz 6 Hz 60 Hz Premium (Cu rotor) Exceeds NEMA / T 256T 3 Hz 60 Hz 6 Hz 60 Hz Premium (Cu rotor) Exceeds NEMA Premium (Cu rotor) T 256T 3 Hz 60 Hz 6 Hz 60 Hz Low Voltage AC Selection and Pricing Guide 10-1 Dimensions

220 Introduction General Purpose Duty Duty Purpose Dimensions General Purpose & - TEFC GP10A / GP10 / SD10 HP Synch RPM F.L. RPM Frame No Load Current [A] Full Load 460 Volts, NEMA Design B, 40 C Ambient Lckd Rotor kva/ HP Code Nominal Efficiency (%) Power Factor (%) ½ ¾ Full Load ½ ¾ Full Load Full Load (lb-ft) Torque Lckd Rotor Break- Down High Efficiency LR Stall Time Hot (Sec) Cold (Sec) Winding Conn T N wye T M wye T J wye T J wye T L wye T M wye T K wye T H wye T L wye T L wye T K wye T H wye T K wye T K wye T K wye T H wye T J wye T J wye T J wye T F wye T H wye T H wye T H wye T G wye T H wye T H wye T H wye T H delta T G wye T G wye T G delta T G delta T G delta T G delta T G delta T G delta TS G delta T G delta T G delta T G delta TS G delta T G delta T G delta T G delta Prices and specifications are subject to change without notice Low Voltage AC Selection and Pricing Guide

221 General Purpose & - TEFC GP10A / GP10 / SD10 HP Synch RPM Current [A] kva/ F.L. RPM Frame HP No Full Lckd Code Load Load Rotor 460 Volts, NEMA Design B, 40 C Ambient Nominal Efficiency (%) Power Factor (%) ½ ¾ Full Load ½ ¾ Full Load Full Load (lb-ft) Torque Lckd Rotor Break- Down High Efficiency LR Stall Time Hot (Sec) Cold (Sec) Low Voltage AC Selection and Pricing Guide Winding Conn TS G delta T G delta T G delta T G delta TS G delta T G delta T G delta T G delta TS G delta T G delta T G delta T G delta TS G delta T G delta T G delta T G delta TS G delta T G delta T G delta T G delta TS G delta T G delta T G delta T G delta TS G delta T G delta TS G delta T G delta TS G delta T G delta T G delta T G delta TS G delta TS G delta T G delta S449LS G delta TS G delta TS G delta S449LS H delta S449SS G delta S449LS G delta S449LS G delta S449SS G delta S449LS G delta S449LS H delta Prices and specifications are subject to change without notice 10-3 Introduction General Purpose Duty Duty Purpose Dimensions

222 Introduction General Purpose Duty Duty Purpose Dimensions General Purpose & GP100A / GP100 / / (Aluminum Rotor) NEMA Premium Efficiency HP Synch RPM F.L. RPM Frame No Load Current [A] Full Load Lckd Rotor 460 Volts, NEMA Design B, 40 C Ambient kva/ HP Code Nominal Efficiency (%) Power Factor (%) Torque LR Stall Time ½ ¾ Full Min. Load Guar. ½ ¾ Full Load Full Load (lb-ft) Meets or Exceeds Energy Independence & Security Act Efficiency Levels 2010 Lckd Rotor Break- Down Hot (Sec) Cold (Sec) Winding Conn T K Wye T L Wye T K Wye 1 900* T J Wye T L Wye T L Wye T J Wye * T H Wye T L Wye T L Wye T J Wye 2 900* T H Wye T J Wye T K Wye T K Wye 3 900* T H Wye T J Wye T J Wye T J Wye 5 900* T F Wye T H Wye T H Wye T H Wye * T G Wye T H Wye T H Wye T H Wye * T G Delta T G Wye T G Wye T G Delta * T G Delta T G Wye T G Wye T G Delta * T G Delta TS G Delta T G Delta T G Delta * T G Delta TS G Delta T G Delta T G Delta * T G Delta Prices and specifications are subject to change without notice Low Voltage AC Selection and Pricing Guide

223 General Purpose & GP100A / GP100 / / (Aluminum Rotor) NEMA Premium Efficiency HP Synch RPM F.L. RPM Frame No Load Current [A] Full Load Lckd Rotor 460 Volts, NEMA Design B, 40 C Ambient kva/ HP Code Nominal Efficiency (%) Power Factor (%) Torque LR Stall Time ½ ¾ Full Min. Load Guar. ½ ¾ Full Load Full Load (lb-ft) Lckd Rotor Break- Down Hot (Sec) Cold (Sec) Low Voltage AC Selection and Pricing Guide Winding Conn TS G Delta T G Delta T G Delta * T G Delta TS G Delta T G Delta T G Delta * T G Delta TS G Delta T G Delta T G Delta * T G Delta TS G Delta T G Delta T G Delta * T G Delta TS G Delta T G Delta T G Delta * T G Delta TS G Delta T G Delta T G Delta * T G Delta TS G Delta T G Delta T G Delta * T G Delta TS G Delta T G Delta T G Delta * 885 S449LS G Delta TS G Delta T H Delta T H Delta * 885 S449LS G Delta TS G Delta S449LS H Delta S449LS H Delta S449SS G Delta S449LS G Delta S449SS G Delta S449LS G Delta Prices and specifications are subject to change without notice Meets or Exceeds Energy Independence & Security Act Efficiency Levels Introduction General Purpose Duty Duty Purpose Dimensions

224 Introduction General Purpose Duty Duty General Purpose & - TEFC GP100A / GP100 / / (Copper Rotor) NEMA Premium Efficiency Plus HP Synch RPM F.L. RPM Frame No Load Current [A] Full Load Lckd Rotor 460 Volts, NEMA Design B, 40 C Ambient kva/ HP Code Nominal Efficiency (%) Power Factor (%) Torque LR Stall Time ½ ¾ Full Min. Load Guar. ½ ¾ Full Load Full Load (lb-ft) Lckd Rotor Break- Down T N wye T L wye T M wye T M wye T M wye T L wye T K wye T K wye T K wye T J wye T J wye T J wye T H wye T H wye T H wye T H wye T H wye T H wye T G wye T G wye T G wye T G wye Prices and specifications are subject to change without notice * EPAct Efficient - motors only Exceeds Energy Independence & Security Act Efficiency Levels 2010 Hot (Sec) Cold (Sec) Winding Conn. Dimensions Purpose Low Voltage AC Selection and Pricing Guide

225 Notes Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 10-7 Dimensions

226 Introduction General Purpose SD10 MS Multi-Speed 1 Winding Variable Torque HP Current [A] kva/ Synch F.L. Frame HP RPM RPM No Full Lckd Load Load Rotor Code 460 Volts, NEMA Design B, 40 C Ambient 1/ / / T 1.3/ /0.9 11/2.5 K 1,5/ / / T 1.4/ /1 14.6/3.3 K 2/ / / T 1.2/ /1.3 20/4.9 K 3/ / / T 2/1.1 4/1.5 32/5.5 J 5/ / / T 3.6/ /2.4 46/9 J 7,5/ / / T 5.2/ /3.5 63/13 J 10/ / / T 6/ /5.4 81/18 H 15/ / / T 7.7/ / /26 J 20/ / T 10/7.2 25/ /37 G 25/ / T 10.5/8 30/ /46 G 30/ / T 11.5/8.5 35/13 240/554 H 40/ / T 16/ /17 340/81 H 50/ / T 20.5/ / /97 H 60/ / T 26/ / /103 G 75/ / T 26.5/20 86/32 568/120 G 100/ / TS 41.5/31 118/46 804/178 H 100/ /890 B444T 41.5/31 118/46 804/178 H 125/ / TS 46/39 158/ /223 H 125/ /890 B445T 46/39 158/ /223 H 150/ / TS 64.5/ / /273 H 150/ /890 B447T 64.5/ / /273 H 200/ /890 B449T 65/51 230/ /291 G 200/ / TS 65/51 230/ /291 G 250/ / TS 81/59 289/ /366 G 250/ /890 B449T 81/59 289/ /366 G Prices and specifications are subject to change without notice Dimensions Duty Duty Purpose Low Voltage AC Selection and Pricing Guide

227 ½ Nominal Efficiency (%) Power Factor (%) Torque LR Stall Time ¾ Full Load ½ ¾ Full Load Full Load (lb-ft) Lckd Rotor (%) Break-Down (%) Hot (Sec) Cold (Sec) Winding Conn. Introduction General Purpose 70.5/ / / /34 60/42 69/50 3/ / / YY//Y 79.7/ / / / / / / / / YY//Y 82.7/ / / / / / / / / YY//Y 85.5/ / / / / / / / / YY//Y 84.6/ / / / / / / / / YY//Y 85.1/70 86/ /74 62/46 76/ / / / / YY//Y 87.8/ / / / / / / / / YY//Y 89.8/ / /84 69/ / / / / / YY//Y 88.7/80 89/ /84 71/38 51/50 85/ /30 113/54 159/ YY//Y 90.3/ / / /40 84/52 87/60 74/37 140/55 177/ YY//Y 91.9/ / / /44 77/56 88/61 89/45 195/67 240/ YY//Y 92.7/ / / /41 83/53 88/61 124/59 248/88 322/ YY//Y 93.3/ / / /38 83/50 86/58 147/74 265/96 352/ YY//Y 93.3/ /81 93/ /39 81/51 85/59 178/89 284/ / YY//Y 90.5/ / / /45 84/56 86/63 220/ / / YY//Y 94/ / /91 73/40 81/51 84/59 293/ / / YY//Y 94/ / /91 73/40 81/51 84/59 293/ / / YY//Y 92.7/ / / /38 77/48 81/56 367/ / / YY//Y 92.7/ / / /38 77/48 81/56 367/ / / YY//Y 92.1/ / / /39 82/50 85/58 441/ / / YY//Y 92.1/ / / /39 82/50 85/58 441/ / / YY//Y 92.3/ / /93 79/43 85/53 86/58 588/ / / YY//Y 92.3/ / /93 79/43 85/53 86/58 588/ / / YY//Y 92.9/ / /91 79/45 85/56 87/61 735/ / / YY//Y 92.9/ / /91 79/45 85/56 87/61 735/ / / YY//Y Duty Duty Purpose Low Voltage AC Selection and Pricing Guide 10-9 Dimensions

228 Introduction General Purpose Duty Duty Purpose Dimensions & Duty RGZZESD, RGZZESD ID1, RGZZESDI Low Voltage AC Selection and Pricing Guide High Efficiency HP Current [A] kva/ Synch F.L. Frame HP RPM RPM No Full Lckd Load Load Rotor Code 460 Volts, NEMA Design B (except as noted), 40 C Ambient T K T J T H T K T K T K T H T K T K T K T H T K T K T K T H T J T J T J T H T H T H T H T H T H T H T G T H T G T G T G T G T G T G T G T G TS G T G T G T G TS G T G T G T G TS G T G T G T G Prices and specifications are subject to change without notice * NEMA Design A. 1.0SF, Class F.

229 ½ Nominal Efficiency (%) Power Factor (%) Torque LR Stall Time ¾ Full Load ½ ¾ Full Load Full Load (lb-ft) Lckd Rotor (%) Break- Down (%) Hot (Sec) Cold (Sec) Winding Conn. Introduction General Purpose wye wye wye wye wye wye wye wye wye wye wye wye wye wye wye wye wye wye wye wye wye wye wye wye wye wye delta wye wye delta delta wye wye delta delta delta delta delta delta delta delta delta delta delta delta delta delta Low Voltage AC Selection and Pricing Guide Duty Duty Purpose Dimensions

230 Introduction General Purpose Duty Duty Purpose Dimensions & Duty RGZZESD, RGZZESD ID1, RGZZESDI High Efficiency HP Current [A] kva/ Synch F.L. Frame HP RPM RPM No Full Lckd Load Load Rotor Code 460 Volts, NEMA Design B (except as noted), 40 C Ambient TS G T G T G T G TS G T G T G T G TS G T G T G T G TS G T G T G T G TS G T G T G T G TS G T G T G T G TS G T G T G S G TS G T G T G S G TS G S G S G S449SS G S G S G S449SS G S G S H * Prices and specifications are subject to change without notice * NEMA Design A. 1.0SF, Class F Low Voltage AC Selection and Pricing Guide

231 ½ Nominal Efficiency (%) Power Factor (%) Torque LR Stall Time ¾ Full Load ½ ¾ Full Load Full Load (lb-ft) Lckd Rotor (%) Break- Down (%) Hot (Sec) Cold (Sec) Winding Conn. Introduction General Purpose delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta delta Duty Duty Purpose Low Voltage AC Selection and Pricing Guide Dimensions

232 Introduction General Purpose Duty Duty Purpose Dimensions Duty - TEFC RGZESDI HP Synch RPM Frame Speed Range 460 Volts, 40 C Ambient F.L. RPM FL Amps NL Amps Nom. FL Eff. (%) FL Torque (lb-ft) Max Torque Const. HP (lb-ft) Max RPM Const. HP Min Const. Torque 10:1 Constant Torque Ohms/Phase (Y equiv.) Circuit Parameters 25ºC X1 X2 XM R1 R T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: T 10: TS 10: T 10: T 10: T 10: TS 10: T 10: T 10: T 10: TS 10: T 10: T 10: T 10: Prices and specifications are subject to change without notice Efficiency Values are shown for 60 hertz sine wave power Low Voltage AC Selection and Pricing Guide

233 Duty - TEFC RGZESDI HP Synch RPM Frame Speed Range 460 Volts, 40 C Ambient F.L. RPM FL Amps NL Amps Nom. FL Eff. (%) FL Torque (lb-ft) Max Torque Const. HP (lb-ft) Max RPM Const. HP Min Const. Torque 10:1 Constant Torque Ohms/Phase (Y equiv.) Circuit Parameters 25ºC X1 X2 XM R1 R TS 10: T 10: T 10: T 10: TS 10: T 10: T 10: T 10: TS 10: T 10: T 10: T 10: TS 10: T 10: T 10: T 10: TS 10: T 10: T 10: T 10: TS 10: T 10: T 10: T 10: TS 10: T 10: T 10: T 10: TS 10: T 10: T 10: TS 10: TS 10: S449SS 10: S449SS 10: S449SS 10: S449SS 10: S449SS 10: Prices and specifications are subject to change without notice Efficiency Values are shown for 60 hertz sine wave power. Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide Dimensions

234 Introduction General Purpose Duty Duty Purpose Dimensions Duty - TEFC & TEBC RGKESDI & RGZESDI HP Synch RPM Frame Encl. Speed Range 460 Volts, 40 C Ambient F.L. RPM FL Amps NL Amps Nom. FL Eff. (%) FL Torque (lb-ft) Max Torque Const. HP (lb-ft) Max RPM Const. HP 1000:1 Constant Torque Ohms/Phase (Y equiv.) Circuit Parameters 25ºC X1 X2 XM R1 R T TEFC 1000: T TEFC 1000: T TEFC 1000: T TEFC 1000: T TEFC 1000: T TEFC 1000: T TEFC 1000: T TEFC 1000: T TEFC 1000: T TEFC 1000: T TEFC 1000: T TEFC 1000: T TEFC 1000: T TEFC 1000: T TEBC 1000: T TEFC 1000: T TEFC 1000: T TEFC 1000: T TEBC 1000: T TEFC 1000: T TEFC 1000: T TEBC 1000: T TEBC 1000: T TEBC 1000: T TEBC 1000: T TEBC 1000: T TEBC 1000: T TEBC 1000: T TEBC 1000: T TEBC 1000: T TEBC 1000: TS TEBC 1000: T TEBC 1000: T TEBC 1000: T TEBC 1000: TS TEBC 1000: T TEBC 1000: T TEBC 1000: T TEBC 1000: TS TEBC 1000: T TEBC 1000: T TEBC 1000: T TEBC 1000: Prices and specifications are subject to change without notice Efficiency Values are shown for 60 hertz sine wave power Low Voltage AC Selection and Pricing Guide

235 Duty - TEFC & TEBC RGKESDI & RGZESDI HP Synch RPM Frame Encl. Speed Range 460 Volts, 40 C Ambient F.L. RPM FL Amps NL Amps Nom. FL Eff. (%) FL Torque (lb-ft) Max Torque Const. HP (lb-ft) Max RPM Const. HP 1000:1 Constant Torque Ohms/Phase (Y equiv.) Circuit Parameters 25ºC X1 X2 XM R1 R TS TEBC 1000: T TEBC 1000: T TEBC 1000: T TEBC 1000: TS TEBC 1000: T TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: T TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: TS TEBC 1000: S449SS TEBC 1000: TS TEBC 1000: TS TEBC 1000: S449SS TEBC 1000: S449SS TEBC 1000: S449SS TEBC 1000: S449SS TEBC 1000: S449SS TEBC 1000: S449SS TEBC 1000: Prices and specifications are subject to change without notice Efficiency Values are shown for 60 hertz sine wave power Low Voltage AC Selection and Pricing Guide Introduction General Purpose Duty Duty Purpose Dimensions

236 Introduction General Purpose Duty Duty Purpose Dimensions Purpose P-Base (VSS) RGZVESD / RGZVILESD HP Synch RPM F.L. RPM Frame No Load Current [A] Full Load 460 Volts, NEMA Design B, 40 C Ambient Lckd Rotor kva/ HP Code Nominal Efficiency (%) Power Factor (%) ½ ¾ Full Load ½ ¾ Full Full Load Load (lb-ft) Torque Lckd Rotor (%) Break- Down (%) Vertical LR Stall Time Hot (Sec) Cold (Sec) Winding Conn L wye J wye H wye L wye L wye K wye H wye K wye K wye K wye H wye K wye K wye K wye H wye J wye J wye J wye H wye H wye H wye H wye H wye H wye H wye G wye H delta G wye G wye G delta G delta G wye G wye G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta Prices and specifications are subject to change without notice Low Voltage AC Selection and Pricing Guide

237 Purpose P-Base (VSS) RGZVESD / RGZVILESD HP Synch RPM Current [A] kva/ F.L. RPM Frame HP No Full Lckd Code Load Load Rotor 460 Volts, NEMA Design B, 40 C Ambient Nominal Efficiency (%) Power Factor (%) ½ ¾ Full Load ½ ¾ Full Full Load Load (lb-ft) Torque Lckd Rotor (%) Break- Down (%) Vertical LR Stall Time Hot (Sec) Cold (Sec) Winding Conn G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta G delta Prices and specifications are subject to change without notice Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide Dimensions

238 Introduction General Purpose Duty Duty Purpose Dimensions IEC - TEFC 1LA7 Standard Efficiency (eff 2) kw RPM 50HZ 50Hz 60Hz Synch. F.L. 400 Volts, 50Hz - 40 C Ambient Frame Current [A] 50Hz Full Load Locked Rotor Nominal Efficiency 50Hz Low Voltage AC Selection and Pricing Guide Power Factor 50Hz 4/4 3/4 4/4 Full Load Torque [Nm] 50Hz Locked Rotor Break Down J [ Kg m 2 ] Lpf [ db(a) ] M M M M M M M M M M M M M M M M M M M S M M M L M M S L M S L L S L L M L L M S L L S M Prices and specifications are subject to change without notice CEMEP Eff2

239 IEC - TEFC 1LA7 Standard Efficiency (eff 2) kw RPM 50HZ 50Hz 60Hz Synch. F.L. 400 Volts, 50Hz - 40 C Ambient Frame Current [A] 50Hz Full Load Locked Rotor Nominal Efficiency 50Hz Power Factor 50Hz 4/4 3/4 4/4 Full Load Torque [Nm] 50Hz Locked Rotor Break Down J [ Kg m 2 ] Lpf [ db(a) ] M M M M S S M M S M M L M M L M L L Prices and specifications are subject to change without notice CEMEP Eff2 Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide Dimensions

240 Introduction General Purpose Duty Duty Purpose IEC - TEFC 1LA6 Standard Efficiency (eff 2) kw RPM 50Hz 50Hz 60Hz Synch. F.L. 400 Volts, 50Hz - 40 C Ambient Frame Current [A] 50Hz Full Load Locked Rotor Nominal Efficiency 50Hz Power Factor 50Hz 4/4 3/4 4/4 Full Load Torque [Nm] 50Hz Locked Rotor Break Down J [ Kg m 2 ] L Lpf [ db(a) ] L L M L M S L L S M M M M M S S M M S M M L M M L M L L Prices and specifications are subject to change without notice CEMEP Eff1 Dimensions Low Voltage AC Selection and Pricing Guide

241 IEC - TEFC 1LA9 Standard Efficiency (eff 1) kw Synch. RPM F.L. 400 Volts, 50Hz - 40 C Frame Current [A] Full Load Locked Rotor Nominal Efficiency Power Factor 4/4 3/4 4/4 Full Load Torque [Nm] Locked Rotor Break Down J [ Kg m 2 ] Lpf [ db(a) ] M M M M M M M M M M M M M M M S M S L S L L L L M L L M M M S S M S M M M M L M L L Prices and specifications are subject to change without notice Low Voltage AC Selection and Pricing Guide CEMEP Eff Introduction General Purpose Duty Duty Purpose Dimensions

242 Introduction General Purpose Duty Duty Purpose Dimensions IEC - TEFC 1LA9 Standard Efficiency (eff 1) HP Synch. RPM F.L. 460 Volts, 60Hz - 40 C Frame Current [A] Full Load Locked Rotor Nominal Efficiency Power Factor 4/4 4/4 Full Load Torque [Nm] Locked Rotor Break Down J [ Kg m 2 ] Lpf [ db(a) ] EPAct Nr. CC032A M M M M M M M M M M M M M M M S M S L S L L L L M L L M M M S S M S M M M M L M L L Prices and specifications are subject to change without notice Low Voltage AC Selection and Pricing Guide

243 IEC - TEFC 1LG6 Standard Efficiency (eff 1) kw RPM RPM F.L. Frame Current [A] Efficiency Cos φ Torque [Nm] Full Load 460 Volts, 60Hz - 40 C - continued Locked Rotor 4/4 3/4 4/4 Full Load Locked Rotor Break Down J [ Kg m 2 ] Lpf [ db(a) ] L L L M L S M L L M L L M M L S M S M M S M M M M S S S S M M M M L S S L L M M L L L L L L L Prices and specifications are subject to change without notice Low Voltage AC Selection and Pricing Guide CEMEP eff Introduction General Purpose Duty Duty Purpose Dimensions

244 Introduction General Purpose Duty Duty Purpose Dimensions IEC - TEFC 1LG6 High Efficiency (eff 1) kw RPM RPM F.L. Frame 400 Volts 50Hz - 40 C Ambient Current [A] Efficiency Cos φ Torque [Nm] Full Load Locked Rotor 4/4 3/4 4/ Low Voltage AC Selection and Pricing Guide Full Load Locked Rotor Break Down J [ Kg m 2 ] Lpf [ db(a) ] L L L M L S M L L M L L M M L S M S M M S M M M M S S S S M M M M L S S L L M M L L L L L L L CEMEP eff1

245 IEC - TEFC 1LG6 High Efficiency (eff 1) HP RPM RPM F.L. Frame 460 Volts 60Hz - 40 C Ambient Current [A] Efficiency Cos φ Torque [Nm] Full Load Locked Rotor 4/4 4/4 Full Load Locked Rotor Break Down J [ Kg m2 ] Lpf [ db(a) ] Low Voltage AC Selection and Pricing Guide EPAct Nr. CC032A L M L M L L L L M L S M M M M M S M M M M M M S M S M S M M M M S M S L M M L L L L L L L L Prices and specifications are subject to change without notice Introduction General Purpose Duty Duty Purpose Dimensions

246 Introduction General Purpose Duty Duty Purpose Dimensions IEC - TEFC 1MJ6 ATEX - Ex de IIC T4 kw RPM 50Hz 50Hz 60Hz Synch. F.L. 400 Volts, 50Hz - 40 C Ambient Frame Current [A] 50Hz Full Load Locked Rotor Nominal Efficiency 50Hz Power Factor 50Hz 4/4 4/4 Full Load Torque [Nm] 50Hz Locked Rotor Break Down J [ Kg m 2 ] Explosion Proof Lpf [ db(a) ] Terminal Box Material M Alum M Alum M Alum M Alum M Alum L Alum M Alum M Alum M Alum L Alum M Alum M Alum L Alum L Alum M Alum L Alum L Alum L Alum L Alum L Alum L Alum M Alum L Alum L Alum M Alum S Alum L Alum L Alum S Alum M Alum M Alum M Alum M Alum M Alum S Alum S Alum M Alum M Alum S Alum M Alum M Alum L C.I. Prices and specifications are subject to change without notice Low Voltage AC Selection and Pricing Guide

247 IEC - TEFC 1MJ6 ATEX - Ex de IIC T4 kw RPM 50Hz 50Hz 60Hz Synch. F.L. 400 Volts, 50Hz - 40 C Ambient Frame Current [A] 50Hz Full Load Locked Rotor Nominal Efficiency 50Hz Power Factor 50Hz 4/4 4/4 Full Load Torque [Nm] 50Hz Locked Rotor Break Down J [ Kg m 2 ] Explosion Proof Lpf [ db(a) ] Terminal Box Material M Alum M Alum L C.I L Alum M Alum L C.I L Alum L Alum L C.I M Alum L Alum M Alum L Alum L Alum L Alum L Alum L Alum. Prices and specifications are subject to change without notice Introduction General Purpose Duty Duty Purpose Low Voltage AC Selection and Pricing Guide Dimensions

248 Introduction General Purpose Duty Duty IEC - TEFC 1MJ7 ATEX - Ex de IIC T4 kw RPM 50Hz 50Hz 60Hz Synch. F.L. 400 Volts, 50Hz - 40 C Ambient Frame Current [A] 50Hz Full Load Locked Rotor Nominal Efficiency 50Hz Power Factor 50Hz 4/4 4/4 Full Load Torque [Nm] 50Hz Locked Rotor Break Down J [ Kg m 2 ] Explosion Proof Lpf [ db(a) ] S C.I. Terminal Box Material M C.I M C.I M C.I S C.I M C.I S C.I M C.I M C.I S C.I M C.I M C.I M C.I M C.I S C.I S C.I S C.I S C.I M C.I M C.I M C.I M C.I S C.I S C.I M C.I M C.I. Prices and specifications are subject to change without notice Dimensions Purpose Low Voltage AC Selection and Pricing Guide

249 General Purpose GP10A / GP100A - Foot Mounted - Aluminum Introduction General Purpose Duty Duty Frame Poles C 2F N-W P U BA AB 2E D O Keyseat R S ES 143T All T All T (1) All T (2) All T (1) All T (2) All T (3) All T (4) All T (3) All T (4) All T (5) All T (6) All T (5) All T (6) All * Optional 4.5 inch AK is available for 182/184TC frame motors. Contact factory if required. (1) All GP10A except 5HP, 1800RPM & 1.5HP, 900RPM. (2) All GP100A and 5HP, 1800RPM & 1.5HP, 900RPM GP10A. (3) All GP10A except 10HP, 3600RPM & 10HP, 1800RPM. (4) All GP100A and 10HP, 3600RPM & 10HP, 1800RPM GP10A. (5) All GP10A. (6) All GP100A. * Optional 4.5 inch AK is available for 182/184TC frame motors. Contact factory if required. (1) Not according to NEMA standard All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames. Purpose Low Voltage AC Selection and Pricing Guide 11-1 Dimensions

250 Introduction General Purpose General Purpose GP10A / GP100A - C-Face Foot Mounted, Footless - Aluminum Frames Purpose Duty Duty Dimensions Frame Poles C 2F N-W P U BA AB 2E D O Low Voltage AC Selection and Pricing Guide Keyseat C-Face R S ES AH AJ AK BD BF # BF 143T All / T All / T (1) All * / T (2) All * / T (1) All * / T (2) All * / T (3) All / T (4) All / T (3) All / T (4) All / T (5) All / T (6) All / T (5) All / T (6) All /2-13 * Optional 4.5 inch AK is available for 182/184TC frame motors. Contact factory if required. (1) All GP10A except 5HP, 1800RPM & 1.5HP, 900RPM. (2) All GP100A and 5HP, 1800RPM & 1.5HP, 900RPM GP10A. (3) All GP10A except 10HP, 3600RPM & 10HP, 1800RPM. (4) All GP100A and 10HP, 3600RPM & 10HP, 1800RPM GP10A. (5) All GP10A. (6) All GP100A. * Optional 4.5 inch AK is available for 182/184TC frame motors. Contact factory if required. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet.

251 General Purpose GP10A / GP100A - D Flange Foot Mounted, Footless - Aluminum Frames Introduction General Purpose Duty Duty Purpose Frame Poles C 2F N-W P U BA AB 2E D O Keyseat D Flange R S ES AH AJ AK BD BF # BF 143T All T All T (1) All T (2) All T (1) All T (2) All T (3) All T (4) All T (3) All T (4) All T (5) All T (6) All T (5) All T (6) All * Optional 4.5 inch AK is available for 182/184TC frame motors. Contact factory if required. (1) All GP10A except 5HP, 1800RPM & 1.5HP, 900RPM. (2) All GP100A and 5HP, 1800RPM & 1.5HP, 900RPM GP10A. (3) All GP10A except 10HP, 3600RPM & 10HP, 1800RPM. (4) All GP100A and 10HP, 3600RPM & 10HP, 1800RPM GP10A. (5) All GP10A. (6) All GP100A. * Optional 4.5 inch AK is available for 182/184TC frame motors. Contact factory if required. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet Low Voltage AC Selection and Pricing Guide 11-3 Dimensions

252 Introduction General Purpose General Purpose GP10 - Foot Mounted - Frames Purpose Frame Poles C 2F N-W (1) P U BA AB 2E D O Keyseat R S ES 143T All T All T All T All T All T All T All T All T All T All TS All TS All T All T All TS All TS All * Optional 4.5 inch AK is available for 182/184TC frame motors. Contact factory if required. (1) Not according to NEMA standard. All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames. Dimensions Duty Duty Low Voltage AC Selection and Pricing Guide

253 General Purpose GP10 - Foot Mounted - Frames Introduction General Purpose Duty Duty Frame Poles C 2F N-W (1) P U AB AB 2E D O Keyseat R S ES 364T All T All TS All TS All T All T All TS All TS All T All T All TS All TS All T All TS All T All TS All * Only for 400HP, 2 Pole (1) Not according to NEMA standard. All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames. Purpose Low Voltage AC Selection and Pricing Guide 11-5 Dimensions

254 Introduction General Purpose General Purpose GP10 - C-Face Foot Mounted, Footless - Frames Purpose Duty Duty Dimensions Frame Poles C 2F N-W P U BA AB 2E D O Keyseat C-Face R S ES AH AJ AK BD BF # BF 143T All / T All / T All * / T All * / T All / T All / T All / T All / T All /2"-13NC 286T All /2"-13NC 284TS All /2"-13NC 286TS All /2"-13NC 324T All /8"-11NC 326T All /8"-11NC 324TS All /8"-11NC 326TS All /8"-11NC (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet Low Voltage AC Selection and Pricing Guide

255 General Purpose GP10 - C-Face Foot Mounted, Footless - Frames Introduction General Purpose Duty Duty Purpose Frame Poles C 2F N-W P U BA AB 2E D O Keyseat C-Face R S ES AH AJ AK BD BF # BF 364T All /8"-11NC 365T All /8"-11NC 364TS All /8"-11NC 365TS All /8"-11NC 404T All /8"-11NC 405T All /8"-11NC 404TS All /8"-11NC 405TS All /8"-11NC 444T All /8"-11NC 445T All /8"-11NC 444TS All /8"-11NC 445TS All /8"-11NC 447T All /8"-11NC 447TS All /8"-11NC 449T All /8"-11NC 449TS All /8"-11NC (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet Low Voltage AC Selection and Pricing Guide 11-7 Dimensions

256 Introduction General Purpose General Purpose GP10 - D Flange Foot Mounted, Footless - Frames Purpose Duty Duty Dimensions Frame Poles C 2F N-W P U BA AB 2E D O Keyseat D Flange R S ES AH AJ AK BD BF # BF 143T All T All T All T All T All T All T All T All T All T All TS All TS All T All T All TS All TS All (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet Low Voltage AC Selection and Pricing Guide

257 General Purpose GP10 - D Flange Foot Mounted, Footless - Frames Introduction General Purpose Duty Duty Purpose Frame Poles C 2F N-W P U BA AB 2E D O Keyseat D Flange R S ES AH AJ AK BD BF # BF 364T All T All TS All TS All T All T All TS All TS All T All T All TS All TS All T All TS All T All TS All (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet Low Voltage AC Selection and Pricing Guide 11-9 Dimensions

258 Introduction General Purpose General Purpose GP100 Foot Mounted + C-Face + D Flange - Frames Purpose Duty Duty Dimensions Frame C 2F N-W P U BA AB 2E D O Keyseat C-Face with Feet D Flange with Feet R S ES AH AJ AK BD BF AH AJ AK BD BF 143T / T / T * / T * / T / T / T / T / * Optional 4.5 inch AK is available for 182/184TC frame motors. Contact factory if required Low Voltage AC Selection and Pricing Guide

259 General Purpose GP100 Footless C-Face, D Flange - Frames Introduction General Purpose Duty Duty Purpose Frame C N-W P U AB O Keyseat C-Face without Feet D Flange without Feet R S ES AH AJ AK BD BF AH AJ AK BD BF 143T / T / T * / T * / T / T / T / T / * Optional 4.5 inch AK is available for 182/184TC frame motors. Contact factory if required Low Voltage AC Selection and Pricing Guide Dimensions

260 Introduction General Purpose SD10 - Foot Mounted - Frames Purpose Frame Poles C 2F N-W (1) P U BA AB 2E D O Keyseat R S ES 143T All T All T All T All T All T All T All T All T All T All TS All TS All T All T All TS All TS All * Optional 4.5 inch AK is available for 182/184TC frame motors. Contact factory if required. (1) Not according to NEMA standard. All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames. Dimensions Duty Duty Low Voltage AC Selection and Pricing Guide

261 SD10 - Foot Mounted - Frames S440 Introduction General Purpose Duty Duty Frame Poles C 2F N-W (1) P U BA AB 2E D O Keyseat R S ES 364T All T All TS All TS All T All T All TS All TS All T All T All TS All TS All T All TS All T All TS All S449LS All S449SS All * Only for 400HP, 2 Pole. (1) Not according to NEMA standard. All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames. Purpose Low Voltage AC Selection and Pricing Guide Dimensions

262 Introduction General Purpose SD10 - C-Face Foot Mounted, Footless - Frames Purpose Duty Duty Dimensions Frame Poles C 2F N-W P U BA AB 2E D O Keyseat C-Face R S ES AH AJ AK BD BF # BF 143TC All / TC All / TC All * / TC All * / TC All / TC All / TC All / TC All / TC All /2"-13NC 286TC All /2"-13NC 284TSC All /2"-13NC 286TSC All /2"-13NC 324TC All /8"-11NC 326TC All /8"-11NC 324TSC All /8"-11NC 326TSC All /8"-11NC (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet Low Voltage AC Selection and Pricing Guide

263 SD10 - C-Face Foot Mounted, Footless - Frames Introduction General Purpose Duty Duty Purpose Frame Poles C 2F N-W P U BA AB 2E D O Keyseat C-Face R S ES AH AJ AK BD BF# BF 364TC All /8"-11NC 365TC All /8"-11NC 364TSC All /8"-11NC 365TSC All /8"-11NC 404TC All /8"-11NC 405TC All /8"-11NC 404TSC All /8"-11NC 405TSC All /8"-11NC 444TC All /8"-11NC 445TC All /8"-11NC 444TSC All /8"-11NC 445TSC All /8"-11NC 447TC All /8"-11NC 447TSC All /8"-11NC 449TC All /8"-11NC 449TSC All /8"-11NC (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet Low Voltage AC Selection and Pricing Guide Dimensions

264 Introduction General Purpose SD10 - D Flange Foot Mounted, Footless - Frames Purpose Duty Duty Dimensions Frame Poles C 2F N-W P U BA AB 2E D O Keyseat D Flange R S ES AH AJ AK BD BF # BF 143TD All TD All TD All TD All TD All TD All TD All TD All TD All TD All TSD All TSD All TD All TD All TSD All TSD All (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet Low Voltage AC Selection and Pricing Guide

265 SD10 - D Flange Foot Mounted, Footless - Frames Introduction General Purpose Duty Duty Purpose Frame Poles C 2F N-W P U BA AB 2E D O Keyseat D Flange R S ES AH AJ AK BD BF # BF 364TD All TD All TSD All TSD All TD All TD All TSD All TSD All TD All TD All TSD All TSD All TD All TSD All TD All TSD All (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet Low Voltage AC Selection and Pricing Guide Dimensions

266 Introduction General Purpose - Foot Mounted - Frames Purpose Frame Poles C 2F N-W (1) P U BA AB 2E D O Keyseat R S ES 143T T T T T T T T T 4, T 4, TS TS 4, TS TS 4, T 4, T 4, TS TS 4, TS TS 4, * Optional 4.5 inch AK is available for 182/184TC frame motors. Contact factory if required. (1) Not according to NEMA standard. All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames. Dimensions Duty Duty Low Voltage AC Selection and Pricing Guide

267 - Foot Mounted - Frames Introduction General Purpose Duty Duty Frame Poles C 2F N-W (1) P U BA AB 2E D O Keyseat R S ES 364T 4, T 4, TS TS 4, TS TS 4, T T TS TS T T TS TS T TS T TS S449LS S449SS S449SS * * Only for 400HP, 2 Pole. (1) Not according to NEMA standard. All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames. Purpose Low Voltage AC Selection and Pricing Guide Dimensions

268 Introduction General Purpose - C-Face Foot Mounted, Footless - Frames Purpose Duty Duty Dimensions Frame Poles C 2F N-W P U BA AB 2E D O Low Voltage AC Selection and Pricing Guide Keyseat C-Face R S ES AH AJ AK BD BF # BF 143TC (1) /8"-16NC 145TC (1) /8"-16NC 182TC (1) /2"-13NC 182TCH (1) /2"-13NC 184TC (1) /2"-13NC 184TCH (1) /2"-13NC 213TC (1) /2"-13NC 215TC (1) /2"-13NC 254TC (1) /2"-13NC 256TC (1) /2"-13NC 284TC 4, /2"-13NC 286TC 4, /2"-13NC 284TSC /2"-13NC 284TSC 4, /2"-13NC 286TSC /2"-13NC 286TSC 4, /2"-13NC 324TC 4, /8"-11NC 326TC 4, /8"-11NC 324TSC /8"-11NC 324TSC 4, /8"-11NC 326TSC /8"-11NC 326TSC 4, /8"-11NC (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet.

269 - C-Face Foot Mounted, Footless - Frames S440 Introduction General Purpose Duty Duty Purpose Frame Poles C 2F N-W P U BA AB 2E D O Keyseat C-Face R S ES AH AJ AK BD BF # BF 364T 4, /8"-11NC 365T 4, /8"-11NC 364TS /8"-11NC 364TS 4, /8"-11NC 365TS /8"-11NC 365TS 4, /8"-11NC 404T /8"-11NC 405T /8"-11NC 404TS /8"-11NC 405TS /8"-11NC 444T /8"-11NC 445T /8"-11NC 444TS /8"-11NC 445TS /8"-11NC 447T /8"-11NC 447TS /8"-11NC 449T /8"-11NC 449TS /8"-11NC S449LS /8"-11NC S449SS /8"-11NC (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet Low Voltage AC Selection and Pricing Guide Dimensions

270 Introduction General Purpose - D Flange Foot Mounted, Footless - Frames Purpose Duty Duty Dimensions Frame Poles C 2F N-W P U BA AB 2E D O Low Voltage AC Selection and Pricing Guide Keyseat D Flange R S ES AH AJ AK BD BF # BF 143TD (1) TD (1) TD (1) TD (1) TD (1) TD (1) TD (1) TD (1) TD 4, (1) TD 4, (1) TSD TSD 4, TSD TSD 4, TD 4, TD 4, TSD TSD 4, TSD TSD 4, (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet

271 - D Flange Foot Mounted, Footless - Frames S440 Introduction General Purpose Duty Duty Purpose Frame Poles C 2F N-W P U BA AB 2E D O Keyseat D Flange R S ES AH AJ AK BD BF # BF 364TD 4, TD 4, TSD TSD 4, TSD TSD 4, TD TD TSD TSD TD TD TSD TSD TD TSD TD TSD S449LSD S449SSD (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet Low Voltage AC Selection and Pricing Guide Dimensions

272 Introduction General Purpose (Cast Iron Frame) - Foot Mounted - Frames Duty Duty Purpose Dimensions Frame Poles C 2F N-W P U AB BA (1) 2E D O Low Voltage AC Selection and Pricing Guide Keyseat R S ES 143T 2,4,6, T 2,4,6, T 2, T 4, T 2, T 4, T 2, T 4, T 2, T 4, T 2, T 4, T 2, T 4, T T 4, T T 4, TS 2, TS 4, TS 2, TS 4, T T 4, T T 4, TS TS 4, TS TS 4, (1) Not according to NEMA standard. All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames.

273 (Cast Iron Frame) - Foot Mounted - Frames Introduction General Purpose Duty Duty Frame Poles C 2F N-W P U AB BA (1) 2E D O Keyseat R S ES 364T T 4, T T 4, TS TS 4, TS TS 4, T T TS TS T T TS TS T TS T TS S449LS S449LS ** S449SS S449SS * (1) Not according to NEMA standard. ** Only for 400HP, 2 Pole. ** Only for 300, 350 & 400HP, 4 Pole. All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames Low Voltage AC Selection and Pricing Guide Purpose Dimensions

274 Introduction General Purpose C-Face Foot Mounted, Footless - Frames Purpose Duty Dimensions Duty Frame Poles C 2F N-W P U AB BA (1) 2E D O Low Voltage AC Selection and Pricing Guide Keyseat C-Face R S ES AH AJ AK BD BF # BF 143TC 2,4, /8"-16NC 145TC 2,4, /8"-16NC 182TC /2"-13NC 182TC 4, /2"-13NC 182TCH /2"-13NC 182TCH 4, /2"-13NC 184TC /2"-13NC 184TC 4, /2"-13NC 184TCH /2"-13NC 184TCH 4, /2"-13NC 213TC /2"-13NC 213TC 4, /2"-13NC 215TC /2"-13NC 215TC 4, /2"-13NC 254TC /2"-13NC 254TC 4, /2"-13NC 256TC /2"-13NC 256TC 4, /2"-13NC 284TC 4, /2"-13NC 284TC 4, /2"-13NC 286TC 4, /2"-13NC 286TC 4, /2"-13NC (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames.

275 C-Face Foot Mounted, Footless - Frames Introduction General Purpose Duty Duty Purpose Frame Poles C 2F N-W P U AB BA (1) 2E D O Keyseat D Flange R S ES AH AJ AK BD BF # BF 284TSC /2"-13NC 284TSC 4, /2"-13NC 286TSC /2"-13NC 286TSC 4, /2"-13NC 324TC 4, /8"-11NC 324TC 4, /8"-11NC 326TC 4, /8"-11NC 326TC 4, /8"-11NC 324TSC /8"-11NC 324TSC 4, /8"-11NC 326TSC /8"-11NC 326TSC 4, /8"-11NC 364TC 4, /8"-11NC 364TC 4, /8"-11NC 365TC 4, /8"-11NC 365TC 4, /8"-11NC 364TSC /8"-11NC 364TSC 4, /8"-11NC 365TSC /8"-11NC 365TSC 4, /8"-11NC (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames Low Voltage AC Selection and Pricing Guide Dimensions

276 Introduction General Purpose C Face Foot Mounted, Footless - Frames 400 S440 Purpose Duty Duty Dimensions Frame Poles C 2F N-W P U AB BA (1) 2E D O Keyseat D Flange R S ES AH AJ AK BD BF # BF 404TC /8"-11NC 405TC /8"-11NC 404TSC /8"-11NC 405TSC /8"-11NC 444TC /8"-11NC 445TC /8"-11NC 444TSC /8"-11NC 445TSC /8"-11NC 447TC /8"-11NC 447TSC /8"-11NC 449TC /8"-11NC 449TSC /8"-11NC S449LS /8"-11NC S449LS ** /8"-11NC S449SS /8"-11NC S449SS * /8"-11NC ** Only for 400HP, 2 Pole ** Only for 300, 350 & 400HP, 4 Pole (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames Low Voltage AC Selection and Pricing Guide

277 D Flange Foot Mounted, Footless - Frames Introduction General Purpose Duty Duty Purpose Frame Poles C 2F N-W P U BA (1) BA 2E D O Keyseat D Flange R S ES AH AJ AK BD BF # BF 143TD 2,4, TD 2,4, TD TD 4, TD TD 4, TD TD 4, TD TD 4, TD TD 4, TD TD 4, TD 4, TD 4, TD 4, TD 4, (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames Low Voltage AC Selection and Pricing Guide Dimensions

278 Introduction General Purpose D Flange Foot Mounted, Footless - Frames Purpose Duty Duty Dimensions Frame Poles C 2F N-W P U AB BA (1) 2E D O Low Voltage AC Selection and Pricing Guide Keyseat D Flange R S ES AH AJ AK BD BF # BF 284TSD TSD 4, TSD TSD 4, TD 4, TD 4, TD 4, TD 4, TSD TSD 4, TSD TSD 4, TD 4, TD 4, TD 4, TD 4, TSD TSD 4, TSD TSD 4, (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames. All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames.

279 D Flange Foot Mounted, Footless - Frames S440 Introduction General Purpose Duty Duty Purpose Frame Poles C 2F N-W P U AB BA (1) 2E D O Keyseat D Flange R S ES AH AJ AK BD BF # BF 404TD TD TSD TSD TD TD TSD TSD TD TSD TD TSD S449LS S449LS ** S449SS S449SS * ** Only for 400HP, 2 Pole ** Only for 300, 350 & 400HP, 4 Pole (1) Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches. S449 frame motors are only available with feet All of the above motors have 8 hole footprints except 182 to 286 frames (2 pole only) and S449 frames Low Voltage AC Selection and Pricing Guide Dimensions

280 Introduction General Purpose General Purpose, Severe & Duty - TEFC RGZP / RGZESD / RGZZESD Duty Purpose Dimensions Duty Frame S R ES C D E 2F BA N-W O P AB U 143T T T T T T T T T T TS TS T T TS TS T T TS TS T T TS TS T T TS TS T TS T TS S449LS S449SS Low Voltage AC Selection and Pricing Guide

281 General Purpose, Severe & Duty - TEFC RGZP / RGZESD / RGZZESD C-Face with & without feet Introduction General Purpose Duty Duty Purpose Frame BD AJ AK U AH BA ES S BF # BF DIA 143/5TC ** /8"-16NC 182/4TC * ** /2"-13NC 213/5TC ** /2"-13NC 254/6TC ** /2"-13NC 284/6TC /2"-13NC 284/6TSC /2"-13NC 324/6TC /8"-11NC 324/6TSC /8"-11NC 364/5TC /8"-11NC 364/5TSC /8"-11NC 404/5TC /8"-11NC 404/5TSC /8"-11NC 444/5TC /8"-11NC 444/5TSC /8"-11NC 447TC /8"-11NC 447TSC /8"-11NC 449TC /8"-11NC 449TSC /8"-11NC ** Optional 4.5 inch AK (See 143/5TC) is available for 182/4TC. Contact factory if required. ** Not according to NEMA standard. Drip Cover dimension (when used) - max. 3 inches Low Voltage AC Selection and Pricing Guide Dimensions

282 Introduction General Purpose Duty RGZESDI / RGZZESDI Figure A Totally Enclosed Fan Cooled Duty Purpose Dimensions Duty Frame XC XD XE C D E 2F BA N-W O P W AB U 143T * 145T * 182T * 184T * 213T * 215T * 254T ** 256T ** 284T ** 286T ** 284TS ** 286TS ** 324T ** 326T ** 324TS ** 326TS ** 364T ** 365T ** 364TS ** 365TS ** 404T ** 405T ** 404TS ** 405TS ** 444T ** 445T ** 444TS ** 445TS ** 447T TS T TS S449LS S449SS ** Tolerance: +0.00, ** Tolerance: +0.00, Low Voltage AC Selection and Pricing Guide

283 Duty RGZESDI Figure B Totally Enclosed Fan Blower Cooled with or without Encoder Introduction General Purpose Duty Frame XC XD XE C D E 2F BA N-W O P W AB U 143T ** 145T ** 182T ** 184T ** 213T ** 215T ** 254T ** 256T ** 284T ** 286T ** 284TS ** 286TS ** 324T ** 326T ** 324TS ** 326TS ** 364T ** 365T ** 364TS ** 365TS ** 404T ** 405T ** 404TS ** 405TS ** 444T ** 445T ** 444TS ** 445TS ** 447T TS T TS S449LS S449SS ** Tolerance: +0.00, Low Voltage AC Selection and Pricing Guide Duty Purpose Dimensions

284 Introduction General Purpose Duty RGZESDI Figure C Motor with Lake Shore SL56 Encoder Duty Duty Frame XC XD XE C D E 2F BA N-W O P W AB U 143T , , T , , T , , T , , Purpose Duty RGZESDI Figure D Motor with internally Mounted Encoder Dimensions Frame XC XD XE C D E 2F BA N-W O P W AB U 404T , , T , , TS , , TS , , T , , T , , TS , , TS , , T TS T TS S449LS S449SS Low Voltage AC Selection and Pricing Guide

285 Duty RGZESDI Figure E Motor with Dynapar HS35 Encoder Introduction General Purpose Duty Frame XC XD XE C D E 2F BA N-W O P W AB U 143T * 0.875*** 145T * 0.875*** 182T * 1.125*** 184T * 1.125*** 213T * 1.375*** 215T * 1.375*** 254T ** 1.625*** 256T ** 1.625*** 284T ** 1.875*** 286T ** 1.875*** 284TS ** 1.625*** 286TS ** 1.625*** 324T ** 2.125*** 326T ** 2.125*** 324TS ** 1.875*** 326TS ** 1.875*** 364T ** 2.375*** 365T ** 2.375*** 364TS ** 1.875*** 365TS ** 1.875*** 404T ** 2.875*** 405T ** 2.875*** 404TS ** 2.125*** 405TS ** 2.125*** 444T ** 3.375*** 445T ** 3.375*** 444TS ** 2.375*** 445TS ** 2.375*** 447T TS T TS S449LS S449SS *** Tolerance: *** Tolerance: *** Tolerance: Low Voltage AC Selection and Pricing Guide Duty Purpose Dimensions

General Purpose - TEFC Motors GP10 / RGZP (Cast Iron Frame)

General Purpose - TEFC Motors GP10 / RGZP (Cast Iron Frame) - TEFC Motors The GP10 and RGZP motors are ideal for both indoor and outdoor applications and in operating atmospheres that contain moisture, dust and grit. These industry workhorses are ideal for use

More information

Severe Duty / IEEE TEFC Motors SD100 IEEE841 / RGZEESDX

Severe Duty / IEEE TEFC Motors SD100 IEEE841 / RGZEESDX / IEEE 841 - TEFC Motors Introduction The IEEE 841 motors meets or exceeds IEEE 841-2001 standards for energy efficiency, high performance, variable speed operation, rugged construction and long service

More information

SIMOTICS NEMA Motors. Low Voltage AC Motors Selection and Pricing Guide. usa.siemens.com/motors

SIMOTICS NEMA Motors. Low Voltage AC Motors Selection and Pricing Guide. usa.siemens.com/motors SIMOTICS NEMA Motors Low Voltage AC Motors Selection and Pricing Guide usa.siemens.com/motors D81.2 Edition 04/2015 Buy With Confidence Buying a motor can be a difficult process. Is it the right size for

More information

Low Voltage AC Motors

Low Voltage AC Motors Low Voltage AC Motors Selection and Pricing Guide Catalog D81.2-2012, USA Edition SIMOTICS NEMA Motors www.usa.siemens.com/nema-motors Table of Contents Introduction Wide Selection of Motors 1-1 Energy

More information

Severe duty cast iron frame motors

Severe duty cast iron frame motors Severe duty cast iron frame motors When the going gets tough, these motors keep going SIMOTICS NEMA Low Voltage Motors www.usa.siemens.com/motors Siemens SIMOTICS low voltage severe duty motors Built to

More information

General purpose aluminum frame motors. The right choice for efficiency and performance. SIMOTICS NEMA Low Voltage Motors.

General purpose aluminum frame motors. The right choice for efficiency and performance. SIMOTICS NEMA Low Voltage Motors. General purpose aluminum frame motors The right choice for efficiency and performance SIMOTICS NEMA Low Voltage Motors www.usa.siemens.com/motors Siemens GP100A Aluminum Frame Motors Precision construction,

More information

Powerful + Efficient + Reliable

Powerful + Efficient + Reliable 1 THRU 50HP NEMA 140T THRU 449T HIGH EFFICIENCY ISO9001 CERTIFIED Powerful + Efficient + Reliable TEFC CAST IRON FRAMES CLASS F INSULATED 1.15 SERVICE FACTOR OVER SIZED BEARINGS LOW-LOSS ELECTRICAL GRADE

More information

MAX-E1 HIGH EFFICIENCY. Severe Duty

MAX-E1 HIGH EFFICIENCY. Severe Duty MAX-E1 HIGH EFFICIENCY Severe Duty DESIGN FEATURES & CONSTRUCTION ALL MAX-E1 MOTORS DELIVER THESE IMPRESSIVE DESIGN FEATURES HPE - High Pulse Endurance Wire Non-hygroscopic, Class F insulation system High-grade,

More information

General purpose cast iron frame motors. The right choice for optimal durability, efficiency and performance. SIMOTICS NEMA Low Voltage Motors

General purpose cast iron frame motors. The right choice for optimal durability, efficiency and performance. SIMOTICS NEMA Low Voltage Motors General purpose cast iron frame motors The right choice for optimal durability, efficiency and performance SIMOTICS NEMA Low Voltage Motors www.usa.siemens.com/motors Siemens SIMOTICS low voltage cast

More information

5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA MG1 (2003) Part 31,

5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA MG1 (2003) Part 31, 5 Year Warranty Premium Efficiency, TEFC Enclosure Inverter Duty Motors Corona Resistant Magnet Wire CSA Certified, UL, CE NEMA M1 (003) Part 31, DefinitePurpose Inverter Fed Motors Inverter Shield TM

More information

Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 92

Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 92 Premium Efficiency Exceeds Effciency Levels Mandated by CSA C390 and EPACT 9 Crown Triton TM Series Premium Efficiency Motors Experience Combined with Technology yundai Induction Motors use Finite Element

More information

NEMA Premium Efficiency T-Frame Motors. Three-Phase, TEFC Enclosures RELIABILITY MATTERS

NEMA Premium Efficiency T-Frame Motors. Three-Phase, TEFC Enclosures RELIABILITY MATTERS NEMA Premium Efficiency T-Frame Motors Three-Phase, TEFC Enclosures RELIABILITY MATTERS RELIABILITY MATTERS Aurora Motors a leading global supplier of NEMA premium vertical pump motors and T-frame motors

More information

Brake Motors Aluminium Frame Improved Efficiency EFF2

Brake Motors Aluminium Frame Improved Efficiency EFF2 Motors Energy Automation Coatings Brake Motors Aluminium Frame Improved Efficiency EFF2 Standard Features: Three-phase, multivoltage, IP55, TEFC Output: 0.12 up to 11kW Frames: 63 up to 132M Voltage: 220-240/380-415V

More information

INDEX NEMA PREMIUM EFFICIENCY

INDEX NEMA PREMIUM EFFICIENCY INDEX S EED EXC DS R TS O DAR MEE E STAN CE THREE-PHASE MOTORS - FEATURES & LIST PRICES THREE-PHASE MOTORS TEFC - Foot-Mount................... A-51 A-54 TEFC C-Flange........................ A-55 ODP

More information

SUPER-MAX INDUCTION MOTOR

SUPER-MAX INDUCTION MOTOR Compliance Certificate No.CC014A CSA Listed No. 1077944 SUPER-MAX INDUCTION MOTOR PREMIUM EFFICIENCY SERIES CSA Certified for Class I Division 2 Groups A, B, C, D T3C TOTALLY ENCLOSED FAN COOLED FRAME:

More information

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency The Baldor uper-e In the mid-70s, a southeastern tire manufacturing plant asked Baldor to increase their plant s operating efficiencies. After analyzing the efficiencies of the plant s 75 Hp motors, Baldor

More information

GE Energy. X$D Ultra 841. NEMA Premium Extra Severe Duty Motors Frame HP

GE Energy. X$D Ultra 841. NEMA Premium Extra Severe Duty Motors Frame HP GE Energy X$D Ultra 841 Premium Extra Severe Duty Motors 143-449 Frame 0.75-300 HP GE sets the standard with powerful features. We are dedicated to the future. Since Edison s time at the leading edge of

More information

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base THREE PHASE MOTORS DRIP-PROOF RPM 60 HP Hz 1/4 1725 1725 S56 100027 $246 A 16 208-230/460 1.4 58.0 9.24 1/3 3450 48 101447 251 A 14 208-230/460 1.4 68.0 9.00 1725 48 100446 266 A 17 208-230/460 1.6 64.3

More information

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY

MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY MAX-E1 FAMILY NEMA PREMIUM EFFICIENCY TYPE AEHE, AEHH8N, AEHH8NCF, AEUH8NDC Effective 05-01-13 Supercedes 08-01-11 APPLICATIONS: Fans & Blowers Compressor Any Severe Duty/ Petro-Chem/ Pumps Mixers Pulp

More information

X$DUltra NEMA Premium 7 Extra Severe Duty Motors Frame 3/4-250 HP

X$DUltra NEMA Premium 7 Extra Severe Duty Motors Frame 3/4-250 HP gmotors X$DUltra 7 841 NEMA Premium 7 Extra Severe Duty Motors 143-449 Frame 3/4-250 HP GE sets the standard... We are dedicated to the future. Since Edison s time at the leading edge of discovery, GE

More information

Over 525 Stock Motor Ratings. The Right Pump Motor for your Application. Leadership in Premium Efficiency. 1

Over 525 Stock Motor Ratings. The Right Pump Motor for your Application. Leadership in Premium Efficiency.   1 Baldor Pump Motors Baldor Reliance is the leading supplier of Pump Motors to meet industrial and commercial applications. From industrial waste water to commercial pool pump motors Baldor Reliance pump

More information

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities.

A. Fan motors and associated equipment shall be sized to operate at 110% of calculated loads and capacities. PART 1: GENERAL 1.01 This design guidelines contained herein includes the requirements electric motors utilized for electric motor driven systems at Texas State University. It is the intention of this

More information

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency The Baldor uper-e In the mid-70s, a southeastern tire manufacturing plant asked Baldor to increase their plant s operating efficiencies. After analyzing the efficiencies of the plant s 75 Hp motors, Baldor

More information

Aluminium Frame Motors Improved Efficiency EFF2

Aluminium Frame Motors Improved Efficiency EFF2 Motors Energy Automation Coatings Aluminium Frame Motors Improved Efficiency EFF2 Standard Features: Three-phase, multivoltage, IP55, TEFC : 0.12 up to 11kW Frames: 63 up to 132M Voltage: 220-240/380-415V

More information

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency

The Baldor Super-E. Over 1,000 Stock Motor Ratings. The Right Premium Efficient Motor for your Application. Leadership in Premium Efficiency The Baldor uper-e In the mid-70s, a southeastern tire manufacturing plant asked Baldor to increase their plant s operating efficiencies. After analyzing the efficiencies of the plant s 75 Hp motors, Baldor

More information

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications

Three Phase Modifiable NEMA Horizontal Motors Accessories and Modifications 1. Altitude Standard motors are designed for 3,300 feet altitude and 40 C ambient temperature. Atmospheric conditions at higher altitudes inhibit the motor s ability to dissipate heat, resulting in an

More information

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents. PART 1: GENERAL 1.01 This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the

More information

Inverter Speed Ratio Information

Inverter Speed Ratio Information Inverter Speed Ratio Information Guidelines for Application of General Purpose,, Single Speed on Variable Frequency Drives Meets NEMA MG1-2006 Part 30 and Part 31 Section 4.4.2 Unless stated otherwise,

More information

Matched drive-motor combination package

Matched drive-motor combination package usa.siemens.com/drives Matched drive-motor combination package Integrated Drive Systems SINAMICS V20 and SIMOTICS GP100A Answers for industry. Why choose Siemens for your integrated drive system? Integrated

More information

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2 Motors Energy Automation Coatings Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2 Standard Features: Three-phase, multivoltage, IP66, TEFC : 0.12 up to 250kW Frames: 63 up to 355M/L Voltage:

More information

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1)

Products & Services EQ Series AC Drives. TEAMMaster WOUND ROTOR MOTORS WORLD SERIES SYNCHRONOUS MOTORS. EXPLOSION PROOF (Division 1, Zone 1) 630-543-7867 Products & Services EQ7 1-1000 hp Intelligent Keypad with Extensive Diagnostics Select Any of 4 Control Methods - V/ Hz - Dynamic Torque - Sensorless Vector - Closed-loop Vector Quick Setup

More information

Powered to Perform. Electric Motors

Powered to Perform. Electric Motors Powered to Perform Electric Motors Built and Tested to Deliver Trans-Power brand motors use tested, proven designs to keep running strong day after day. They also include features that translate into reliability

More information

Your Source for a Complete Line of Electric Motors. Rolled Steel Motors. A Complete Line of Single Phase and Three Phase Rolled Steel Motors

Your Source for a Complete Line of Electric Motors. Rolled Steel Motors. A Complete Line of Single Phase and Three Phase Rolled Steel Motors Your Source for a Complete Line of Electric Motors Rolled Steel Motors A Complete Line of Single Phase and Three Phase Rolled Steel Motors Mission Statement To provide the United States market for industrial

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Vertical Hollowshaft Electric Motors C O N T E N T S Revised 04/14/2016 SPECIFICATIONS - DETAILED PROVISIONS Section 16151 - Vertical Hollowshaft Electric Motors C O N T E N T S PART 1 - GENERAL... 1 1.01 SCOPE... 1 1.02 SPECIFIC PROJECT REQUIREMENTS...

More information

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL

Design Standard. Electric Motors. Detailed specifications follow. PART 1 - GENERAL Design Standard Detailed specifications follow. PART 1 - GENERAL 1.01 SCOPE This design guidelines contained herein include the requirements of electric motors utilized for electric motor driven systems

More information

Severe Duty is Standard with WEG W22 motors

Severe Duty is Standard with WEG W22 motors W22 Severe Duty TEFC Severe Duty is Standard with WEG W22 motors W22 Severe Duty TEFC Severe Duty High performance with maximum energy efficiency is the goal of the new WEG electric motor. High efficiency

More information

7.0 High HP Low and Medium Voltage

7.0 High HP Low and Medium Voltage TABLE OF CONTENTS 7.0 High HP Low and 7.1 Quantum LMV - TEFC Low Voltage 7.7 Quantum LMV - TEFC 7.12 449 Frame TEFC 7.16 WPII, TEFC, TEAAC Standard Features 7.17 WPII Pricing and Kits 7.20 Pegasus MHV

More information

Features and Benefits

Features and Benefits Features and Benefits ELECTRICAL DESIN z 1 500 HP; 2, 4, 6 pole z 3600, 1800, 1200 RPM z 3 Phase, 60 Hz, 460V z Motors can be rerated for 380, 400 and 415 VAC at 50 Hz. z Designed to meet NEMA M1, M13,

More information

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features

General Purpose Three Phase Motors TEFC (IP55) High Efficiency. Standard Features TM WEG W21 Severe Duty motors meet the most demanding severe duty application requirements. These TEFC motors are all cast iron construction, with enclosures rated IP55 to handle wet and dirty environments.

More information

NORDIC-PREMIUM EFFICIENCY

NORDIC-PREMIUM EFFICIENCY CANADIAN STANDARDS ASSOCIAT ION EEV NORDIC-PREMIUM EICIENCY CAST IRON PREMIUM EICIENCY ELECTRIC MOTORS VD COMPATIBLE Meets or exceeds NeMA MG-1 table 1-1 premium efficiency corona & spike resistant MAGNet

More information

NEMA Premium, High, and Standard Efficiency Vertical Hollow Shaft Pump Motors RELIABILITY MATTERS

NEMA Premium, High, and Standard Efficiency Vertical Hollow Shaft Pump Motors RELIABILITY MATTERS NEMA Premium, High, and Standard Efficiency RELIABILITY MATTERS Blue = 90c 50m 0y 0k Blue = Pantone 285C Gray = 40% Black (For reverse logo use 30%) R E L I A B I L I T Y M AT T E R S Aurora Motors a leading

More information

1LG0 Low-voltage Motors

1LG0 Low-voltage Motors Low-voltage motors up to 315kW Catalog D81.5.1 1LG Low-voltage Motors Answers for industry. 1 Table of Contents Overview 3 Motor standards 5 Mechanical design 6 Electrical design 1 Converter fed application

More information

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE

WATTSAVER PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE PREMIUM EFFICIENCY MOTORS GENERAL PURPOSE The line of premium efficiency motors is now inverter capable. LEESON s unique IRIS voltage-spike-resistant insulation system is standard at no extra cost. motors

More information

The Best Value in Washdown Duty Motors and Drives

The Best Value in Washdown Duty Motors and Drives The Best Value in Washdown Duty Motors and Drives Long before we invested in the people, equipment and material required to produce Baldor Reliance Washdown Duty motors and drives, we invested our time

More information

MAX-VH. Vertical Hollow Shaft Motors

MAX-VH. Vertical Hollow Shaft Motors MAX-VH Vertical Hollow Shaft Motors Specifications OTHER PERFORMANCE CONSTRUCTION APPLICATION RATING Item Type Of Motors Design Standards Voltages Frequency Output Range RPM (SYN.) Time Duty Frame Size

More information

Medallion TM AC Motors Selection and Pricing Guide

Medallion TM AC Motors Selection and Pricing Guide 2004 Medallion TM AC Motors Selection and Pricing Guide Siemens Medallion Motors for Solutions to Your Application Problems Severe Duty Motors Siemens SEVERE DUTY motors are built to give our customers

More information

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013 ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame Australian Version October 2013 ODP SERIES (OPEN DRIP PROOF) PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS, C280M TO C355LB FRAME

More information

W22 Medium Voltage Motors TEFC - Severe Duty

W22 Medium Voltage Motors TEFC - Severe Duty 101 www.pamensky.com W22 Medium Voltage Motors TEFC - Severe Duty Standard Features Three-phase, 2, 4, 6 and 8 pole, 60Hz Voltage: 1200V, 2300V, 2400V, 3300V, 4000V, 4160V & 6600V Totally Enclosed Fan

More information

VEM3546 1HP 1800RPM 3PH 56C Tefc Motor. Features. Description. Manufacturer Information

VEM3546 1HP 1800RPM 3PH 56C Tefc Motor. Features. Description. Manufacturer Information 3804 outh treet 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 VEM3546 1HP 1800RPM 3PH 56C Tefc Motor Baldor Electric CO. Catalog Number Manufacturer Description Weight per unit Product

More information

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1

AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1 AEEB AEVB LOW VOLTAGE SERIES Three-Phase Squirrel Cage Induction Motor Conforming to SS530 (Occasional Use) Conforming to IE1 STANDARD AND SPECIFICATION Performance: Meet the requirement of Singapore standard

More information

Vertical Pump Motors

Vertical Pump Motors NEMA Premium, High, and Standard Efficiency Vertical Pump Motors WP1 or TEFC Enclosures available with Hollow Shaft or Solid Shaft RELIABILITY MATTERS RELIABILITY MATTERS Aurora Motors a leading global

More information

SECTION MOTOR REQUIREMENTS for HVAC

SECTION MOTOR REQUIREMENTS for HVAC PART 1 GENERAL 1.1 SECTION INCLUDES A. Single-phase electric motors B. Three-phase electric motors 1.2 REFERENCES SECTION 23 05 13 MOTOR REQUIREMENTS for HVAC A. ABMA 9 - Load Ratings and Fatigue Life

More information

RGZESDI Inverter Duty AC Induction Motors

RGZESDI Inverter Duty AC Induction Motors November 1999 RGZESDI Inverter Duty AC Induction Motors Installation Operation Maintenance Instructions Frames: 143T through S449SS/LS SIGNAL WORDS The signal words Danger, Warning and Caution used in

More information

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS

SEWPCC UPGRADING/EXPANSION PROJECT BID OPPORTUNITY SECTION LOW-VOLTAGE AC INDUCTION MOTORS SECTION 26 20 00 LOW-VOLTAGE AC INDUCTION MOTORS SEWPCC UPGRADING/EXPANSION PROJECT PART 1 GENERAL 1.1 RELATED SECTIONS A. This section applies only when referenced by a motor-driven equipment specification.

More information

Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power.

Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power. 200 Volt, TEFC, Foot Mounted 1/2 thru 0 200 & 7 Volt 6C thru 26T Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power. Features:

More information

Super-E Premium Efficient Motors

Super-E Premium Efficient Motors Super-E Premium Efficient Motors Why Baldor? Customer Preference 20% 1985 50% 1990 90% 2000 94% 2003 95.5% 2007 The percentages shown reflect results of studies conducted in which Baldor was chosen as

More information

200 & 575 Volt Motors. 200 Volt, Three Phase, TEFC, Foot Mounted. 1/2 thru 50 Hp NEMA 56C thru 326T

200 & 575 Volt Motors. 200 Volt, Three Phase, TEFC, Foot Mounted. 1/2 thru 50 Hp NEMA 56C thru 326T Farm Duty 200 Volt, TEFC, Foot Mounted 200 & 7 Volt 1/2 thru 0 6C thru 26T Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200 volt power.

More information

SB380. Sept Rev. A

SB380. Sept Rev. A SB380 Sept. 2010 Rev. A Features pertaining to stock line ODP TEFC C-Face CCP Power range (stock) 1 1/2-200HP 1 1/2-200HP 1 1/2-100HP 1-50HP Frame construction (Rolled Steel) 180-210 N/A 180-210 140-210

More information

5 Year Warranty Chemical & Process Duty Motors, IEEE-841 (2001) Premium Efficiency TEFC Severe Duty Design Corona Resistant Magnet Wire Class 1,

5 Year Warranty Chemical & Process Duty Motors, IEEE-841 (2001) Premium Efficiency TEFC Severe Duty Design Corona Resistant Magnet Wire Class 1, 5 Year Warranty Chemical & Process Duty Motors, IEEE81 (1) Premium Efficiency TEFC Severe Duty Design Corona Resistant Magnet Wire Class 1, Division, roups A, B, C, D Class 1, Zone, roups A, B & C CSA

More information

1/2 thru 50 Hp NEMA 56C thru 326T

1/2 thru 50 Hp NEMA 56C thru 326T 200 Volt, TEFC, Foot Mounted Cast Iron Foot Mounted 200 & 7 Volt 1/2 thru 0 6C thru 26T Applications: Pumps, fans, compressors, blowers, machine tools, conveyors and many other applications requiring 200

More information

Industrial and Commercial Duty IEC Motors

Industrial and Commercial Duty IEC Motors Industrial and Commercial Duty IEC Motors A Regal Brand Five product families delivering a world of opportunity LEESON Passport Series IEC Motors. There s a world of opportunity right here at home. The

More information

SIMOTICS GP Frame sizes 80 and 90

SIMOTICS GP Frame sizes 80 and 90 Siemens AG 1 SIMOTICS GP General Purpose Motors - Frame sizes 8 and 9 Outstanding reliability made in Germany www.siemens.com/simotics-gp Brochure Edition January 1 Answers for industry. Siemens AG 1 SIMOTICS

More information

Warranty Policy No-Fault Warranty (excludes Washdown motors)

Warranty Policy No-Fault Warranty (excludes Washdown motors) Warranty Policy No-Fault Warranty (excludes Washdown motors) Motors with frame sizes 215T and smaller are covered under a No-Fault warranty. This warranty claim is offered one time, per end-user, per application.

More information

List Price. Mult. Sym. C Dim. Single Phase

List Price. Mult. Sym. C Dim. Single Phase Single and Three Phase, Foot Mounted Explosion Proof 1/4 thru 300 48 thru 449TY Applications: Ideal for use where hazardous fumes or dust may be present. Features: U.L. and CSA approved for Class I, Group

More information

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase Single and Three Phase, Foot Mounted Explosion Proof 1/4 thru 300 48 thru 449TY Applications: Ideal for use where hazardous fumes or dust may be present. Features: U.L. and CSA approved for Class I, Group

More information

A Full Line of Low Voltage IEC Motors In-Stock

A Full Line of Low Voltage IEC Motors In-Stock BUILT TO PERFORM WHERE OTHERS FAIL A Full Line of Low Voltage IEC Motors In-Stock Distributed by Elektrim Motors Authorized Distributor: www.elektrimmotors.com or call 855-Go-Elektrim 0.08-220HP Low Voltage

More information

Medium Voltage Motors and Soft Starters

Medium Voltage Motors and Soft Starters TEFC Severe Duty Motors TEFC Motors 2300 4160V................................................. A-252 TEFC Motors Add-On Modifications............................................. A-253 TEFC 2300V - Electrical

More information

champion series motors

champion series motors Introducing A brand new series of Super Performers Data Sheet champion series motors FRAME SIZE 63-132M TEFC 3 Phase Squirrel Cage Induction Motors Siemens CHAMPION Series Cage Motors are suitable for

More information

PRODUCTIVITY HAS A NAME. Torque Master Motors

PRODUCTIVITY HAS A NAME. Torque Master Motors PRODUCTIVITY HAS A NAME Torque Master Motors Premium Efficient Torque Master Motors TORQUE MASTER PE A FORCE TO BE RECKONED WITH Quality. Performance. Dependability. That s what the Torque Master series

More information

NEMA & IEC Product Features and Benefits

NEMA & IEC Product Features and Benefits NEMA & IEC Product Features and Benefits BEAUTY BENEATH THE SURFACE. Looking at a Techtop electric motor, it would be understandable if you thought it was just another NEMA or IEC squirrel-cage induction

More information

Product Information Packet M1509T 7.5/3.8HP,1740/860RPM,3PH,60HZ,215T,3754

Product Information Packet M1509T 7.5/3.8HP,1740/860RPM,3PH,60HZ,215T,3754 Product Information Packet M1509T 7.5/3.8HP,1740/860RPM,3PH,60HZ,215T,3754 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10 A6C A5C-B6C B5C B5H Model Power Voltages Model IP55 A6C A5C B6C B5C B5H Up to 2.400 kw Up to 11.000 V LV A6C - B6C - A5C - B5C MV B5H Frame 71 560 Pole 2, 4, 6, 8 and 10 Cooling IC 411 ( IC 416 optional)

More information

Product Information Packet VM HP,1725RPM,3PH,60HZ,56C,3413M,TEFC,F1

Product Information Packet VM HP,1725RPM,3PH,60HZ,56C,3413M,TEFC,F1 Product Information Packet VM3534.33HP,1725RPM,3PH,60HZ,56C,3413M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

AC Induction Motors. Installation and operating instructions

AC Induction Motors. Installation and operating instructions AC Induction Motors Installation and File No: 48.80 Date: january 28, 2014 Supersedes: 48.80 Date: july 30, 2013 contents Receiving inspection and handling 4 Installation / mounting 4 Location 5 Electrical

More information

W22 NEMA Brake Motors - NEMA Premium

W22 NEMA Brake Motors - NEMA Premium 101 www.pamensky.com TEFC Standard Features Motors are compliant with DOE and NRCAN Three-phase, 2, 4, 6 and 8 pole, 60Hz Voltage: 208-230/460V, 575V Brake power supply: 220/230/240/460/575V Totally Enclosed

More information

How do you take the first step towards an energy efficient future?

How do you take the first step towards an energy efficient future? How do you take the first step towards an energy efficient future? Low-voltage induction motors according to the new standard and new classes Answers for industry. EU Directive 2005/32/EC and IEC 60034-30

More information

SECTION OWNER FURNISHED EQUIPMENT

SECTION OWNER FURNISHED EQUIPMENT SECTION 11000 - OWNER FURNISHED EQUIPMENT PART I - GENERAL 1.01 GENERAL: A. The Owner has prepurchased and has or will have on site various pieces of equipment to be installed by the Contractor under this

More information

Large AC Motors. Synchronous Reluctance Kiln Duty Submersible Accessories & Kits. Large AC Motors. Modifications Large AC M-211

Large AC Motors. Synchronous Reluctance Kiln Duty Submersible Accessories & Kits. Large AC Motors. Modifications Large AC M-211 Synchronous Reluctance Kiln Duty Submersible Accessories & Kits Modifications Large AC M-211 large_ac_motors.fm Page 212 Monday, December 15, 2003 3:47 PM, Quickship and Modifiable 250 HP - 1500 HP 3600

More information

Inverter Duty AC Motors

Inverter Duty AC Motors inverter_duty_ac_motors.fm Page 225 Tuesday, December 17, 2002 3:12 PM RPM AC RPM III Medium DC Motors Index 225 Index RPM III Medium DC Motors RPM AC Inverter Duty Vector Inverter Duty Totally Enclosed

More information

E L E C T R I C WIRE ROPE H O I S T S

E L E C T R I C WIRE ROPE H O I S T S E L E C T R I C WIRE ROPE H O I S T S RH Electric Wire Rope Hoists Harrington RH wire rope hoists are designed and built for today s heavy-duty wire rope hoist applications including fabricating, die handling,

More information

Product Information Packet VEM3665T 5HP,1755RPM,3PH,60HZ,184TC,0642M,TEFC,F1

Product Information Packet VEM3665T 5HP,1755RPM,3PH,60HZ,184TC,0642M,TEFC,F1 Product Information Packet VEM3665T 5HP,1755RPM,3PH,60HZ,184TC,0642M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

: B3; B5; B14; B34; B35; V1

: B3; B5; B14; B34; B35; V1 ATT WE series (Eff1) are 3-phase TEFC Cast-Iron high efficiency general purpose induction motors, which are designed to meet or exceed the requirements for energy efficiency such as: European Eff1, Australia

More information

Ultra Series. Vertical Pump Motors HP. Durability, Reliability and Efficiency at the Heart of Industrial Operations

Ultra Series. Vertical Pump Motors HP. Durability, Reliability and Efficiency at the Heart of Industrial Operations GE Energy Connections Power Conversion Ultra Series Vertical Pump Motors 3-1000 HP Durability, Reliability and Efficiency at the Heart of Industrial Operations Motor technology for tomorrows challenges.

More information

AC METRIC (IEC) MOTORS THREE PHASE

AC METRIC (IEC) MOTORS THREE PHASE These high efficiency motors meet North American performance standards and EPACT energy efficiency mandates, and have.5 service factors. Typically used for replacement on machine tools, textile machinery

More information

841XL PREMIUM EFFICIENCY MOTORS

841XL PREMIUM EFFICIENCY MOTORS 841XL PREMIUM EFFICIENCY MOTORS 8 4 1 X L A C M O T O R S D E S I G N E D T O M E E T Y O U R S E V E RE D U T Y N E E D S As an original member of the NEMA Energy Task Force, Rockwell Automation has

More information

Table of Contents 90% 50% 20%

Table of Contents 90% 50% 20% Why Baldor? For over 80 years, Baldor has strived to provide customers with the best value and reliability in industrial electric motors. That dedication shows in customer preference for Baldor motors.

More information

Inverter Duty and Inverter Duty - Vector Performance AC Motor Product Line

Inverter Duty and Inverter Duty - Vector Performance AC Motor Product Line Large AC Inverter Duty and Inverter Duty - Vector Performance AC Motor Product Line Inverter Duty 1/3-2 HP, 56-140 frame sizes, Explosion Proof, Class I, Groups C & D, Class 2, Groups F & G, XT - Extra

More information

Energy Independence & Securities Act Frequently Asked Questions

Energy Independence & Securities Act Frequently Asked Questions What does EISA stand for? Energy Independence & Securities Act Frequently Asked Questions EISA is the acronym for the Energy Independence & Securities Act. This law was signed on Dec. 19, 2007. This law

More information

Modifiable TITAN Horizontal Motors Accessories and Modifications

Modifiable TITAN Horizontal Motors Accessories and Modifications 36. Rotor, Standard And Optional Construction Standard rotor construction of 449, 5000 and 5800 frame TITAN products is typically die-cast aluminum. 720 RPM and slower is typically fabricated aluminum.

More information

Product Information Packet EM3611T 3HP,1760RPM,3PH,60HZ,182T,3632M,TEFC,F1

Product Information Packet EM3611T 3HP,1760RPM,3PH,60HZ,182T,3632M,TEFC,F1 Product Information Packet EM3611T 3HP,1760RPM,3PH,60HZ,182T,3632M,TEFC,F1 Copyright All product information within this document is subject to ABB Motors and Mechanical Inc. copyright protection, unless

More information

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe Equipment The Squirrel Cage Induction Motor Frames 280 to 315M are totally enclosed fan cooled (TEFC) motors with integral cast cooling fins on frame and end shields. They have winding designs which are

More information

Blue Chip Severe Duty / Cooling Tower: Single Speed EPAct Efficiency

Blue Chip Severe Duty / Cooling Tower: Single Speed EPAct Efficiency Blue Chip Severe Duty / Cooling Tower: Single Speed EPAct Efficiency Rigid Base, Three Phase IP55 Features: Blue Chip quality, 100% cast iron construction for rigidity and reduced vibration Internal and

More information

Horizontal Motors Conversions & Accessories Descriptions & Adders

Horizontal Motors Conversions & Accessories Descriptions & Adders Horizontal Motors Conversions & Accessories VERTICAL All Cast Iron Construction Cast Iron Conduit Box Adder: - 153 161 193 209 234 242 346 483 636 - - - Replacement of steel conduit box with cast iron

More information

BRCP6SM ITT. CentriPro. 6-10" Submersible Motors. For 6" and Larger Deep Well Pumps. Engineered for life

BRCP6SM ITT. CentriPro. 6-10 Submersible Motors. For 6 and Larger Deep Well Pumps. Engineered for life ITT BRCP6SM CentriPro 6-10" Submersible s For 6" and Larger Deep Well Pumps Engineered for life Single Phase, 6" s (1.15 S.F.) and Required Control Boxes Diameter F.L. S.F. Control Box HP kw Volts Order

More information

Energy Saving Three Phase Motors

Energy Saving Three Phase Motors e-drive Energy Saving Three Phase Motors IEC frames 56 to 400 Outputs 0.09 to 630 IE2 MEPS2006 Type: AHE Aluminium Motors Type: HE Cast-Iron Motors 1 When you need all the features of a premium quality

More information

W21 HIGH EFFICIENCY GENERAL PURPOSE MOTORS

W21 HIGH EFFICIENCY GENERAL PURPOSE MOTORS W21 HIGH EFFICIENCY MOTORS!"#$&'#(&)*"&+,-&"./&0,,12#3&4,.5&!"00&678997:;?@&ABCD7=EF=G Data subject to change without notice. PDF processed with CutePDF evaluation edition www.cutepdf.com :7BD ROLLED

More information

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Reg No: 1999/027771/07 (Pty) Ltd 7 Spanner Rd / PO Box 467 Olifantsfontein 1665 Tel: +27 (11) 316 4601 Fax: +27 (11) 316 5670 E-mail: admin-mgr@explolabs.co.za GOVERNMENT APPROVED TEST LABORATORY IN TERMS

More information

Motors Automation Energy Coatings. CrusherDuty. g Roller Bearing. g Reinforced Cast Iron. g Durable. Motor TPH Starter.

Motors Automation Energy Coatings. CrusherDuty. g Roller Bearing. g Reinforced Cast Iron. g Durable. Motor TPH Starter. Motors Automation Energy Coatings CrusherDuty Motor TPH Starter g Roller Bearing g Reinforced Cast Iron g Durable g Quality CD0808 FOR THE MOST DEMANDING ROCK CRUSHER APPLICATIONS WEG Crusher Duty motors

More information

FACTORY MODIFICATION PRICING Effective Supercedes

FACTORY MODIFICATION PRICING Effective Supercedes FACTORY MODIFICATION PRICING MODIFICATION LEAD TIME 1. TWMC standard lead time for all modifications is 5-10 working days. If quicker lead time is required, please contact TWMC. Expediting fees may apply.

More information

S R ATE TOO EG M R G G A

S R ATE TOO EG M R G G A MOTORS AGGREGATE AGGREGATE MOTORS THE RIGHT PRODUCT IN THE TOUGHEST CONDITIONS For decades, aggregate operators have come to depend on Baldor products to keep their facilities operating at optimum efficiency

More information