6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum

Size: px
Start display at page:

Download "6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum"

Transcription

1 . Selection Pump Panel Design N = Freedom 2 = A200 V = Vacuum Class 54 = Type 3R pump panel fusible disconnect 55 = Type 3R pump panel circuit breaker disconnect 4 = Part winding with motor circuit 5 = Part winding circuit breaker disconnect 8 = Duplex non-combination 9 = Duplex disconnect switch 70 = Duplex circuit breaker disconnect EC N 54 2 B A A - NEMA = 2 = 2 3 = 3 4 = 4 5 = 5 = 7 = 7 Enclosure 2 = 3R painted steel A = 3R stainless steel A = None More information on Type, 3R, 4X and 2 duplex pump panels is on Page V0-T-23. Product Selection is on Page V0-T-2. 2 For other voltages and single-phase applications, consult your Eaton representative. 3 OA selector switch and START pushbutton provided as standard. 4 Engineering determination depending on size, horsepower FLA, NEC or other considerations. Modification Code Disconnect Fuse Clip Ratings A = None B = 30A/250V R C = 30A/00V R D = 0A/250V R E = 0A/00V R F = 00A/250V R G = 00A/00V R B = 3A C = 7A D = 5A E = 30A F = 50A G = 00A = 50A J = 250A K = 400A L = 00A Voltage 2 A = 20V/0 or 0/50 B = 240V/0 or 220/50 C = 40V/0 or 440/50 Cover Control 3 = 200A/250V R J = 200A/00V R K = 400A/250V R L = 400A/00V R M = 00A/250V R N = 00A/00V R Q = 200A/00V L Circuit Breaker Ratings M = N = P = Q = R = U = = X = Y = 800A 000A 200A 2000A 3000A 4 70A 00A 50A V0-T-4 Volume 0 Enclosed Control CA080002E January 202

2 . Accessories Kits Kits for Field Mounting Description Suffix Backspin timer 0.2 sec. to 3 min. (0 z) B2 Control transformers 240/480V primary, 20V secondary C 2 C 3 C 4 C 5 C Lightning arrestor L3 Control circuit fuse kit (00V) C3 Electrical interlocks Freedom line/vacuum NO A27 NC A28 C320KGS2 NO and NC A29 C320KGS3 Time delay relay 3 minutes ON delay (unwired) T OFF delay (unwired) T7 24-hour programming clock P44 Interchangeable hubs for enclosure. Enclosure has removable top plate. If conduit hub is required, order: 3/4 in conduit size DS075 -/4 in conduit size DS25 -/2 in conduit size DS50 2 in conduit size DS200 2-/2 in conduit size DS in conduit size DS3002 Power supply C34 Note Does not apply to reduced voltage controllers. Volume 0 Enclosed Control CA080002E January V0-T-5

3 . Overload Relays Freedom Solid-State Overload Relays Three-Phase without Ground Fault Auto/Manual Reset Overload Three-Phase with Ground Fault Auto/Manual Reset Overload NEMA Full Load Current Adjustment Range (A) Selectable Class 0/20/30 Selectable Class 0/20/ R3/A R4/A 5 R3/B R4/B 4 20 R3/C R4/C 0 and R3/A R4/A 5 R3/B R4/B 4 20 R3/C R4/C 9 45 R3/D R4/D R3/D R4/D R3/E R4/E R3/F R4/F R3/G R4/G R3/ R4/ Not UL Listed. 2 NEMA 4 starter available with 30 50A panel mounted CTs and 5A C440 overload relay (C440AA005SELAX or C440A2A005SELAX). 3 NEMA 4 direct mount contactor/overload (28 35A), available February NEMA 5 starter available with 0 300A panel mounted CTs. Starter as an assembled unit with 5A C440 overload relay (C440AA005SELAX or C440A2A005SELAX). 5 NEMA starter available with 20 00A panel mounted CTs. Starter as an assembled unit with 5A C440 overload relay (C440AA005SELAX or C440A2A005SELAX). V0-T- Volume 0 Enclosed Control CA080002E January 202

4 . Freedom Circuit Breaker Product Description Three-phase magnetic Interchangeable heater OLR These ECN55 pump controllers feature the Freedom line starters. They have a AND/OFF/AUTO selector switch and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page V0-T-8. Product Selection Type 3R enclosure does not include top conduit hubs. ubs are available in kit form see table on Page V0-T-5. If branch circuit protective device is 45A or greater, C320FBR fuse kit (panel mounted) may be required for control circuit protection per NEC Class ECN55 Combination Pump Panel Circuit Breaker NEMA Motor Voltage Max. hp 50/0 z Circuit Breaker Stainless steel enclosure may be ordered by changing the seventh digit to A. Type 3R rating will still apply. Starters do not include heater packs. Select one carton of three heater packs. For heater pack selection, see Tab 5. To order without the START pushbutton, add modification code P. 2 NEMA 4 direct mount contactor/overload (28 35A), available February Consult factory in the event ground fault protection is required. 4 Supply hp, voltage, FLA and whether motor is design E or not when ordering the starter. Narrow idth Standard idth 230 7A ECN552BAC-E4 ECN552BAC 3 5A ECN552BAD-E4 ECN552BAD 7-/2 30A ECN552BAE-E4 ECN552BAE 40 3A ECN552CAB-E4 ECN552CAB 3 7A ECN552CAC-E4 ECN552CAC 5 5A ECN552CAD-E4 ECN552CAD 0 30A ECN552CAE-E4 ECN552CAE A ECN5522BAF-E4 ECN5522BAF ECN5522CAF-E4 ECN5522CAF A ECN5532BAG ECN5532CAG A ECN5542BA ECN5542CA A ECN5552BAJ A ECN5552BAK A ECN5552CAJ A ECN5552CAK A ECN552BAL A ECN552BAM A ECN552CAL A 2 ECN552CAM ECN5572BAU ECN5572BAU ECN5572CAU ECN5572CAU For Other Volts and ertz Applications For other than listed volts and hertz, select required controller by catalog number and replace the magnet coil alpha designation, eighth digit in catalog number, with proper code suffix from the table below. Example: For 00V 0 z coil, change ECN552CAC to ECN552DAC. Coil Voltage Coil Volts and ertz Suffix Code 20/0 or 0/50 A 240/0 or 220/50 B 480/0 or 440/50 C 00/0 or 550/50 D 208/0 E Volume 0 Enclosed Control CA080002E January V0-T-9

5 . Dimensions Approximate Dimensions in Inches (mm) Panel Space Panel Space Panel NEMA Position (see figure above) idth eight Narrow (40).0 (52) Standard (2) 2.0 (0) (2) 39.0 (99) 5 A 0.0 (254) 22.0 (559) B 5.0 (38) 2.0 (305) Oversize (38) 39.0 (99) 3.0 (279) 39.0 (99) Note Space is between disconnect switch or circuit breaker and starter. Pos. A Pos. B NEMA s 4 NEMA 5 V0-T-0 Volume 0 Enclosed Control CA080002E January 202

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum .1 Catalog Number Selection Pump Panel Design N = Freedom 2 = A200 V = Vacuum Class 54 = Type 3R pump panel fusible disconnect 55 = Type 3R pump panel circuit breaker disconnect 4 = Part winding with motor

More information

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9 February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

NEMA Vacuum Break Contactors and Starters

NEMA Vacuum Break Contactors and Starters NEMA Vacuum Break Contactors and Starters NEMA Vacuum Break Starter.1 Product Description....................................... Application Description.................................... Operation...............................................

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

Pump Panels Type 3R Enclosure

Pump Panels Type 3R Enclosure Type R Enclosure Product Family Overview June 6 Product escription The utler-hammer Pump ontrollers from Eaton s electrical business are combination starters with accessories and modifications designed

More information

E C N A A F -

E C N A A F - 33-52 NA ontactors & Starters 3-Phase agnetic Starters nclosed Freedom Line January 1 Vol. 2, Ref. No. [0068] Selection Table 33-102. NA Freedom Line nclosed ontrol ing System 33 esign Page N - NA 33-40

More information

NEMA Contactors & Starters (Freedom)

NEMA Contactors & Starters (Freedom) Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1

More information

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection Reduced voltage starters Open & enclosed Reduced voltage starters Description Compact, space saving design 8 starter frame sizes, A16 to A750 Maximum U.L. horsepower ratings Mechanically interlocking as

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents 1 January 00 Reduced Voltage Motor Starters Contents Description Page Open Type S7, Intelligent Technologies (IT.) Soft Starters Product Description............................................. Application

More information

2.1. NEMA Contactors and Starters

2.1. NEMA Contactors and Starters 3A Overload C306DN3B Contents Contactors Non-Reversing and Reversing...... Starters Three-Phase Non-Reversing and Reversing, Full Voltage.................... Starters Single-Phase Non-Reversing, Full Voltage,

More information

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940 Well-Guard Control Pumping Plant Panels Catalog 8940CT9701R11/15 2016 Class 8940 IRRIGATION OIL PRODUCTION CONTENTS Selection.............................................. Page 3 Factory Modifications.....................................

More information

Overload Relay Heater Tables

Overload Relay Heater Tables Overload Relay Tables of Elements for Overload Relays General Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average

More information

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

3.1. NEMA Manual Starters.   Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters... Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp

More information

Definite Purpose Contactors and Starters

Definite Purpose Contactors and Starters 0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................

More information

Contactors & Starters Index

Contactors & Starters Index ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic

More information

NMC Combination Line Starters and Enclosures

NMC Combination Line Starters and Enclosures NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line

More information

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control . 15 5A Starters A27, B27 Contents Description Page 15 60A Contactors C25................... V5-T-6 25 60A Starters A25, B25................. V5-T-9 15 5A Starters A27, B27 Product Selection.......................

More information

Definite Purpose Contactors and Starters

Definite Purpose Contactors and Starters 0 40A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview.............................................. 2 Application Description..........................................

More information

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers

More information

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents June 00 Aftermarket Solutions, Ref. No. [] - CA0000E Contents Description Page Contactors, Starters & Brakes................................... - Product Description.........................................

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

IEC Utilization Categories (Explanation)

IEC Utilization Categories (Explanation) IEC Utilization Categories (Explanation) IEC Utilization Categories Voltage Category Typical Applications A.C. A.C. and D.C. D.C. AC AC AC AC ACa ACb AC6a AC6b AC7a AC7b AC8a AC8b AC AC AC AC AC AC AC

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8 Enclosed Control. Welcome............................................... Eaton Corporation........................................ Eaton Support and Service Center Capabilities.................. Technical

More information

Softstarters Type PSS. Softstarters. General information

Softstarters Type PSS. Softstarters. General information General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide

More information

Definite Purpose Contactors and Starters

Definite Purpose Contactors and Starters 0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................

More information

Definite Purpose Contactors and Starters

Definite Purpose Contactors and Starters 0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................

More information

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description .1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is

More information

SELECTRIC, INC. Selectric (PA) Autotransformer Type Motor Control Panel Installation And Operation Manual

SELECTRIC, INC. Selectric (PA) Autotransformer Type Motor Control Panel Installation And Operation Manual SELECTRIC, INC. Selectric (PA) Autotransformer Type Motor Control Panel Installation And Operation Manual Table of Contents I. Description of Equipment Page 3 II. Description of Operation 3 III. Installation

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,

More information

3 Phase Motor Starter Diagrams Documents

3 Phase Motor Starter Diagrams Documents We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with 3 phase motor starter

More information

Softstarters. Softstarters Power electronic brakes Type PEB

Softstarters. Softstarters Power electronic brakes Type PEB Softstarters Power electronic brakes Softstarters Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB)

More information

MAGNETIC MOTOR STARTERS

MAGNETIC MOTOR STARTERS Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors

More information

Operation and Protection of Motors up to 600Hp at 460Vac (800A)

Operation and Protection of Motors up to 600Hp at 460Vac (800A) Operation and of Motors up to 600Hp at 460Vac (800) WEG enclosed starters series were designed to meet the requirements and flexibility frequently demanded in industrial applications. Featuring components

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Relays.................... C440/XT Electronic

More information

EPS-ECONOMY PUMP STARTER

EPS-ECONOMY PUMP STARTER EPS-ECONOMY PUMP STARTER 1 & 3 Phase, 50/60Z, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides a simple and dependable starting option with a wide electronic overload

More information

Motor Protection. Presented By. Scott Peele PE

Motor Protection. Presented By. Scott Peele PE Motor Protection Presented By Scott Peele PE Motor Protection Overload on the motor load Fuses Heater Magnetic relay Short Circuit on motor circuit Fuses Breakers Single Phasing Overload Protection NEC

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

TDX - Taco Duplex Starter with

TDX - Taco Duplex Starter with Energy Management TDX - Taco Duplex Starter with Smartstart The TDX extends the life of your pumps by alternating control. It comes standard with underload protection, a enhanced class 10 electronic overload

More information

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers Type FEC Epoxy Encapsulated, Copper-Wound Transformers ISO 900:2008 REGISTERED 0 Transformer Selector Guide Type FEC Transformers...Page 02 Primary Fusing Option...Page 07 Primary Overcurrent Selection...Page

More information

Lighting Contactors. 6.1 Open Control. Product Overview...

Lighting Contactors. 6.1 Open Control. Product Overview... Lighting Contactors C30CN Mechanically and Electrically Held.1 Product Overview........................................ C30CN Mechanically and Electrically Held Product Description....................................

More information

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes AE Threaded Combination and Non-Combination Full Motor Starters Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Class I, Division and, Groups C, D Class II, Division

More information

SELECTRIC, INC. Selectric (PX) Full Voltage Type Motor Control Panel Installation And Operation Manual

SELECTRIC, INC. Selectric (PX) Full Voltage Type Motor Control Panel Installation And Operation Manual SELECTRIC, INC. Selectric (PX) Full Voltage Type Motor Control Panel Installation And Operation Manual Table of Contents I. Description of Equipment Page 3 II. Description of Operation 3 III. Installation

More information

Contactors Low Voltage

Contactors Low Voltage 00Motor Starters and January 08 Sheet Motor Starters and ContactorsLow Voltage.0- ContactorsLow Voltage Contents Motor Starters and ContactorsLow Voltage Manual Motor Control MS Starter with Hand/Auto......................................-

More information

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters GE Energy Connections Made in Canada Enclosed Full-Voltage Starters * ca.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal

More information

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES CIRCUIT BREAKERS Explosionproof Circuit Breaker Enclosures BREAKERS Circuit breakers are thermal magnetic type and are available in frame sizes ranging from 15 to 800 amperes Also available as non-automatic

More information

4.1. Lighting Contactors. Contents Description UL Rated AC Contactors Catalog Number Selection...

4.1. Lighting Contactors. Contents Description UL Rated AC Contactors Catalog Number Selection... .1 Contents Description Catalog Number Selection................ Enclosures............................ Cover Control.......................... Product Selection.................... Operation Non-Combination

More information

Accessories and Modification Codes

Accessories and Modification Codes and Modification Codes Side-Mounted Auxiliary Contact.1 Freedom NEMA.......................................... A200 NEMA............................................. XT IEC.................................................

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

Plug and Play Kit Installation and Wiring (Non-Combo and Combo)

Plug and Play Kit Installation and Wiring (Non-Combo and Combo) General Information This publication is to be used for Eaton Plug and Play enclosures designed starters that accept the M22 series 22mm cover control devices. To install the cover control kit (Follow the

More information

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide 32XR 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide RED ALARM LIGHT LEVEL CONTROLLER H-O-A SWITCHES HORN SILENCE INNER DOOR MOTOR STARTERS WITH INTERCHANGEABLE OVERLOAD MODULES

More information

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 H100R3C 3P 100A 600V F-Frame MC Protector Eaton Corp Catalog Number H100R3C Manufacturer Eaton Corp Description Motor Circuit

More information

For Options, Modifications and Accessories, see pages Discount Schedule A6

For Options, Modifications and Accessories, see pages Discount Schedule A6 Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F

More information

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers Instruction Leaflet IL0330300E Supersedes I.L. 7055C, Pages 8, Dated June 998 Instructions for A00, A0, A50 size 6, two- or three-pole non-reversing or reversing motor controllers Contents Description

More information

NEMA Full Voltage Power Devices. Section 1. Control Catalog 1-1

NEMA Full Voltage Power Devices. Section 1.  Control Catalog 1-1 NEMA Rated Full Voltage Power Devices Application Information and Technical Data (300-Line)...-4 Magnetic Nonreversing Starters (CR306, CR386) Basic Features (300-Line) and Technical Features (CR306, CR386)...-7

More information

Motors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2

Motors  GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2 GRUNDFOS GROUNDWATER SERVICE MANUAL Motors 4-6-8-10" CONTENTS Grundfos Motor Specifications... Page 2 Electrical Requirements... Page 8 -Transformer Capacity Maximum Motor Cable Length... Page 10 Full

More information

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany File E31519 Project 10CA65262 February 4, 2011 REPORT on MAGNETIC MOTOR CONTROLLERS Siemens AG Amberg, Germany Copyright 2011 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the

More information

WARREN COUNTY, N.Y. M/E REFERENCE

WARREN COUNTY, N.Y. M/E REFERENCE SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE

More information

4.1. Definite Purpose Contactors and Starters. Contents

4.1. Definite Purpose Contactors and Starters. Contents . Definite Purpose and Starters Product Overview and Starters Definite Purpose and Starters Contents Description Page 20 0A, Compact Single- and Two-Pole C25................................ V5-T- 5 360A,

More information

Self-protected Combination Starters System PKZ 2-SP

Self-protected Combination Starters System PKZ 2-SP Self-protected Combination Starters System PKZ 2-SP 03/035 PKZ 2/ZM/S-SP motor starters: a higher level of protection and versatility : The PKZ 2/ZM/S-SP is a self-protected starter, the first motor controller

More information

Quick selector reference guide. Motor Control Center Aftermarket Buckets

Quick selector reference guide. Motor Control Center Aftermarket Buckets Quick selector reference guide Motor Control Center Aftermarket Buckets 2 EATON WWW.EATON.COM/MCCAFTERMARKET Table of contents Series 2100 MCC bucket Motor Control Center (MCC) Aftermarket Buckets Overview

More information

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com.11 Product Description Features Special Purpose (Type F), Rotating Shaft (Type J),

More information

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters GE Energy Connections Made in USA Enclosed Full-Voltage Starters * www.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal for

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

Contents. Volume 5 Motor Control and Protection CA E April

Contents. Volume 5 Motor Control and Protection CA E April Definite Purpose Contactors and.3 25 60A, Single- and Three-Phase A25, B25 25 60A, Single- and Three-Phase A25, B25 Product Description A25 and B25 Definite Purpose from Eaton s electrical sector combine

More information

SUBMITTAL TRANSMITTAL OCPS CLAY SPRINGS ES REVIEWED SUBMITTAL NUMBER: SUBMITTAL DETAILS: CONTRACTOR/CM:

SUBMITTAL TRANSMITTAL OCPS CLAY SPRINGS ES REVIEWED SUBMITTAL NUMBER: SUBMITTAL DETAILS: CONTRACTOR/CM: OCPS CLAY SPRINGS ES SUBMITTAL DETAILS: SUBJECT: MOTOR CONTROL BUILDING REFERENCE: DATE RECIEVED: Oct 09, 204 DISCIPLINE: Electrical PRIORITY STATUS: 2-STANDARD SPECIFICATION REF: 26 29 REVIEWER DUE DATE:

More information

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the

More information

A200 NEMA Contactors and Starters A200

A200 NEMA Contactors and Starters A200 Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws

More information

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT) 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

Description Definition Cause Effect if not Protected C440/XT Protection Motor Protection

Description Definition Cause Effect if not Protected C440/XT Protection Motor Protection . IEC Contactors and Starters XT IEC Power Control Benefits Reliability and Improved Uptime C0 provides the users with peace of mind knowing that their assets are protected with the highest level of motor

More information

EPS-ECONOMY PUMP STARTER

EPS-ECONOMY PUMP STARTER EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides

More information

XT IEC Power Control Manual Motor Protectors

XT IEC Power Control Manual Motor Protectors May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted

More information

Variable Transformers Series to Amperes

Variable Transformers Series to Amperes Variable Transformers Series 6000 35.0 to 315.0 Amperes ISE, Inc. - 10100 Royalton Rd. - Cleveland, OH 44133 USA - Tel: (440) 237-3200 - Fax: (440) 237-1744 - http://instserv.com 5000/6000 Series Manual,

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

2018 MITCHELL LEWIS SELECTRIC BRAND

2018 MITCHELL LEWIS SELECTRIC BRAND PRODUCT CATALOG TABLE OF CONTENTS TERMS AND CONDITIONS 2 SERVICE RATES 3 Magnetic Starters 5 IEC Across the Line Combination Controllers (circuit breaker type) 6 IEC Across the Line Combination Controllers

More information

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Chapter 8 Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Article 430 of the NEC covers application and installation of

More information

Power electronic brakes

Power electronic brakes Power electronic brakes Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB) Series features full-wave

More information

Hydropak Booster Systems. Series motralec

Hydropak Booster Systems. Series motralec Series 6000 Hydropak Systems motralec 4 rue Lavoisier. ZA Lavoisier. 95223 HERBLAY CEDEX Tel. : 01.39.97.65.10 / Fax. : 01.39.97.68.48 Demande de prix / e-mail : service-commercial@motralec.com www.motralec.com

More information

GPH2 Combination Soft Starters

GPH2 Combination Soft Starters Combination Soft Starters The Combination Soft Starter is a NEMA 4/12 Enclosed industrial general purpose AC motor soft starter package. It is designed for simple and quick installation and start-up, requiring

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Type E/F Simplex & Duplex Pump Controllers

Type E/F Simplex & Duplex Pump Controllers Type E/ Simplex & Duplex Pump Controllers Simplex Pump Controllers A single KTA7 motor controller plus matching CA7 contactor can be combined in an enclosure as a Simplex Combination Controller for pumping

More information

NEMA Contactors and Starters

NEMA Contactors and Starters NM ontactors and Starters NM N16DN0 NM Size 1 Starter.1 Freedom Series Product Overview........................................ Features, enefits and Functions............................ Standards and

More information

ECS 96 R 1 C A A. Voltage D = 575V E = 200V B = 230V C = 460V

ECS 96 R 1 C A A. Voltage D = 575V E = 200V B = 230V C = 460V . Catalog Number Selection S6 Solid-State Soft Starters Class 96 = Non-combination reduced voltage soft starter S6 97 = Combination reduced voltage soft starter, disconnect switch S6 98 = Combination reduced

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. usa.siemens.com/controls

More information

Vacuum Contactors & Starters. Vacuum Contactors & Starters Contents

Vacuum Contactors & Starters. Vacuum Contactors & Starters Contents -1 June 8 Vacuum Contactors & Starters Contents Page NEA, Special Purpose and ining Product Family Overview...................................... -2 Product Selection.............................................

More information

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives. SECTION 230513 - MOTORS AND ADJUSTABLE SPEED DRIVES PART 1 - GENERAL 1.1 DESCRIPTION A. Provide labor, materials, equipment and services as required for the complete installation designed in Contract Documents.

More information

Packaged Design Day Tank Systems

Packaged Design Day Tank Systems Fuel Supply Systems Packaged Design Day Tank Systems for diesel/fuel oil application providing a reliable fuel source for diesel and turbine engine driven equipment and oil fired boilers model & accessory

More information

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran 4 Project:_ Engineer:_ Mitsubishi Electric Automation, Inc. (MEAU) Variable Frequency Drives - HVAC System Submittal Summary Data Form NEMA 1 Bypass Systems Architect:_ Contractor:_ Submitted by: Date:

More information

1 HP 40 HP. List Price Model Number H W D

1 HP 40 HP. List Price Model Number H W D Economical Solu ons for Basic Applica ons Siemens s Non Combina on NEMA R Enclosure PACKAGE VARIABLE TORQUE 240V: /4 HP to 60 HP 480V: 1 HP to 200 HP NON COMBINATION NEMA R ❶ 1 HP 200 HP Ra ngs in Stock

More information

.1 NM ontactors and Starters Product Overview starters and contactors feature a compact, space-saving design, using state-of-the-art technology and th

.1 NM ontactors and Starters Product Overview starters and contactors feature a compact, space-saving design, using state-of-the-art technology and th NM ontactors and Starters NM N16N0 NM Size 1 Starter.1 Product Overview.............................................. Features, enefits and Functions.................................. Standards and ertifications......................................

More information

NEMA Contactors and Starters

NEMA Contactors and Starters NM ontactors and Starters NM N16N0 NM Size 1 Starter NM Size 1 ontactor.1 Product Overview.............................................. 242 Features, enefits and Functions..................................

More information

Sensorless Vector Drives

Sensorless Vector Drives STANDARD PRODUCTS Sensorless Vector Drives SG SERIES STANDARD DUTY / HEAVY DUTY RATINGS Variable Torque: 7.5 to 700HP @ 460V 7.5 to 40HP @ 2V Standard Duty: 7.5 to 600HP @ 460V 7.5 to 40HP @ 2V Heavy Duty:

More information

EBMC Combination Line Starters and Enclosures

EBMC Combination Line Starters and Enclosures EBMC Combination Line 3, 3R, 4, 4X, 7BCD, 9EFG, 12 Applications: Spectrum EBM hinged cover motor control enclosures are used: For general motor control and circuit protection indoors and outdoors in damp,

More information

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals: 3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches

More information