H-Series. Circuit Breaker.

Size: px
Start display at page:

Download "H-Series. Circuit Breaker."

Transcription

1 -Series Circuit Breaker The -Series hydraulic/magnetic circuit breaker provides dependable circuit protection in a low cost, compact package. By meeting the IEC spacing requirements, the -Series is the ideal choice for international market applications. It also features a trip-free mechanism, which will open the contacts when a fault condition occurs, even if the handle is held in the ON position. Although a low cost option, the -Series was designed for maximum performance and reliable equipment protection meeting Carling s stringent quality standards. Key Features & Benefits: Choice of actuator styles U0, CCC, CSA, C. and EN09 approvals Compact size Temperature stable operation -0 o c to 0 o c Choice of terminals, including PCB Single or multi-pole configurations CURVED ROCKER ACTUATOR ANDE ACTUATOR FAT WIT PUS TO RESET ACTUATOR CURVED ROCKER WIT GUARD

2 -Series General Specifi ations Electrical Tables Table A: ists U Recognized, CSA Accepted and TUV Certified configurations and performance capabilities as a Component Supplementary Protector. SERIES - COMPONENT SUPPEMENTARY PROTECTOR CIRCUIT VOTAGE CURRENT SORT CIRCUIT CAPACITY (AMPS) CONFIGURATION MAX U CSA TUV APPICATION CODES RATING FREQ. PASE FU MINIMUM POES WITOUT BACKUP FUSE WITOUT BACKUP FUSE WITOUT BACKUP FUSE U CSA DC (PC) TC, O, U TC, O, U DC TC, O, U 0 DC (PC) TC, O, U TC, O, U SERIES 0 DC (PC) TC, O, U TC, O, U 0 0/ (PC) TC, O, U TC, O, U 0 0/ (PC) TC, O, U TC, O, U 0 0/ (PC) TC, O0, U TC, O0, U - Polarity Sensitive Electrical Maximum Voltage Current Rating Auxiliary Switch Rating Mechanical Endurance Physical Number of Poles Weight Internal Circuit Config. Agency Approvals 0VAC 0/0z 0 VDC Standard current coils:.00,.0,.00,.0, 0.0,.0, 0.0,.0, 0.0,.0 SPDT: 0.A-0VAC,.0A-VDC/0.A-0VDC, 0.A-VAC (with gold contacts) 0,000 ON-OFF per minute; with rated current & voltage - Approx. grams/pole (. oz) Series and Switch Only (with or without auxiliary switch) U Recognized under the Component Recognition Program as Protectors, Supplementary (Guide QVNU File E9) U standard 0 Typical Protector Resistance DCR and Impedance values are based on measurements by the voltmeter ammeter method. Rated current is applied for one hour and at a voltage t less than 0 volts. Ambient temperature: ; Tolerance: Below 0 amps +/- %; Above 0 amps +/-% Impedance Chart Current rating in amperes DC-Ohms Series 0/0z-Ohms CCC certified, Certificate No CSA Accepted Circuit Breaker, CSA standard C. No. TUV certified to EN09, Certificate No. R000 *Manufacturer reserves the right to change product specification without prior tice.

3 -Series Dimensional Specifi ations: in. [mm] andle Actuator

4 -Series Dimensional Specifications: in. [mm] Curved Rocker Actuator #-[M] TREAD *0.[.0] DEEP PCS PER POE 0. [.0] 0. [.00] -POE (J). [.0]. [.].0 [.0]. [.90]. [.00] 0. [.0] 0.0 [.] MAX 0. [9.0]. [.00]. [9.] TAB(Q.C.)TYPE. [9.] SCREW TYPE SCREW TYPE TEMINAS IN SERIES TRIP CIRCUIT CONFIGURATION SOWN. FOR OTERS CONFIGURATIONS, SEE CIRCUIT AND TERMINA DIAGRAMS.. [.] 0. [.0] 0. [0.0] -POE (J).0 [.0].0 [.0] 0.0 [.00] OPTIONA "ROCKER GUARD".0 [.] MAX.9 [0.0] -POE (J).9 [.0] C ON NC.99 [9.00] MAX 0.0 [.00] TYP 0. [9.] -Ø0. [Ø.9] 0. [.99]. [.0]. [9.] POE POE POE MUTI-POE IDENTIFICATION SCEME AS VIEWED FROM TERMINA END OF BREAKER. NOTES:. A DIMENSIONS ARE IN INCES [mm]. TOERANCE +.00 [.] UNESS OTERWISE SPECIFIED. 0.0 [.] PANE CUTOUT DETAI TOERANCE +.00[ +.] UNESS OTERWISE SPECIFIED

5 -Series Dimensional Specifications: in. [mm] Flat Rocker Actuator PUS-TO-RESET ACTUATOR #-[M] TREAD *0.[.0] DEEP PCS PER POE 0. [.00] 0. [.00] -POE () 0. [.0] 0. [.0]. [.0]. [.0] 0.0 [.] MAX 0.0 [.] MAX. [.]. [.].0 [.0].0 [.0] 0.9 [9.] 0. [9.0] 0.9 [9.] 0. [9.0]. [.00].. [9.] [.00] TAB(Q.C.)TYPE. [9.] TAB(Q.C.)TYPE. [9.] SCREW TYPE. [9.] SCREW TYPE. [.90]. [.90]. [.00]. [.00] SCREW TYPE TEMINAS IN SERIES TRIP CIRCUIT CONFIGURATION SOWN. FOR OTERS CONFIGURATIONS, SEE CIRCUIT AND TERMINA DIAGRAMS. -POE (). [.0]. [.0]. [.]. [.].0 [.0].0 [.0] 0. [.00] 0. [.00] 0. [.0] 0. [.0] 0.0 [.] 0.9 [9.] MAX 0.0 [.] 0.9 [9.]. [.] MAX 0. [.0]. [.] 0. [.0] -POE ().0 [.0].0 [.0].0 [.0].0 [.0] 0.0 [.00].0 [.] MAX 0.0 [.00].0 [.] MAX.9 [0.0].9 [0.0].9 [0.0] -POE ().99 [9.00] MAX.99 [9.00].99 MAX [9.00] MAX 0.0 [.00] TYP 0.0 [.00] 0.0 TYP [.00] TYP.9 [.0].9 [.0].9 [.0] 0. [9.] 0. [9.] 0. [9.] -Ø0. [Ø.9] -Ø0. [Ø.9] 0. [.99] 0. [.99] -Ø0. [Ø.9] 0. [.99]. [.0]. [.0]. [9.]. [9.]. [.0]. [9.] 0.0 [.] 0.0 [.] 0.0 [.] MUTI-POE IDENTIFICATION SCEME AS VIEWED FROM TERMINA END OF BREAKER. NOTES:. A DIMENSIONS ARE IN INCES [mm]. TOERANCE +.00 [.] UNESS OTERWISE SPECIFIED. PANE CUTOUT DETAI TOERANCE +.00[ +.] UNESS OTERWISE SPECIFIED

6 -Series Dimensional Specifications: in. [mm] PC Teminals PRINTED CIRCUIT BOARD MOUNTING TERMINA CODE R PRINTED CIRCUIT BOARD MOUNTING TERMINA CODE PRINTED CIRCUIT BOARD MOUNTING TERMINA CODE S & T NOTES:. A DIMENSIONS ARE IN INCES [mm]. TOERANCE +.00 [.] UNESS OTERWISE SPECIFIED.

7 -Series Dimensional Specifications: in. [mm] PC Teminals P.C. FOOT PRINT FOR TERMINA CODE R P.C. FOOT PRINT FOR TERMINA CODE P.C. FOOT PRINT FOR TERMINA CODE S & T NOTES:. A DIMENSIONS ARE IN INCES [mm]. TOERANCE +.00 [.] UNESS OTERWISE SPECIFIED.

8 -Series Dimensional Specifications: in. [mm] Circuit & Terminal CIRCUIT BREAKER MODE ANDE POSITION VS. AUX SWITC MODE STANDARD C/B ANDE POSITION AUX. SWITC MODE OFF 0 OFF NC NO C ON ON 0 NC NO C EECTRICA TRIP 0 OFF O NC NO C 0. [.0] 0. [.0] TERMINA DIMENSIONA DETAI & RATING 0. [.0] 0.9 [.9] 0. [9.9] 0.0 [.0] 0.0 [0.] 0.0 [.0] Ø0.0 [Ø.] TAB (Q.C.) 0.0 [.] 0. [9.00] UPTURN UG 0. [9.00] BUS 0. [.9] 0.9 [.00] 0.0 [.0] 0.9 [.00] 0. [.00] 0.9 [.00] 0. [.00] P.C. TERMINA P.C. TERMINA P.C. TERMINA 90 FACING EFT STRAIGT (SORT) STRAIGT (ONG) 90 FACING RIGT.9 [0.0] BARRIER FOR U-RECOGNIZED MUTI-POE BREAKERS.0 [.0].9 [.00] TABE A TIGTENING TORQUE SPECIFICATIONS TREAD SIZE #- & M MOUNTING ARDWARE #- & M TREAD TERMINA SCREW TABE B TORQUE -9 IN-BS [0.-.0 NM] - IN-BS [.-. NM] DEPT TERMINA DESCRIPTION BEIND PANE TAB (Q.C.).99 [0.0] MAIN SCREW TYPE.99 [0.0].0 TAB (Q.C.). [.] AUX. SWITC* SODER TYPE. [.9] SEE TABE B. [.0] * AVAIABE ON SERIES TRIP AND SWITC ONY CIRCUITS. WEN CAED FOR ON MUTI-POE UNITS, ONY ONE AUX. SWITC IS NORMAY SUPPIED, AS SOWN IN MUTI-POE IDENTIFICATION SCEME.. [.90]. [.90].0 [.0]. [.00] REF 0.0 [.0] 0.0 [0.0]. A DIMENSIONS ARE IN INCES [mm]. TOERANCE ±.00 [.] UNESS OTERWISE SPECIFIED.

9 -Series Dimensional Specifications: in. [mm] Circuit & Terminal 9 B,C B,C G

10 0 -Series Time Delay Values PERCENT OF RATED CURRENT NOTES: Delay Curves,,,,,,,: Breakers to hold 00% and must trip at % of rated current and greater within the time limit shown in this curve. Delay Curves 0,0: Breakers to hold 00% and must trip at 0% of rated current and greater within the time limit shown in this curve. All Curves: Curve data shown represents breaker response at ambient temperature of F ( C) with preloading. Breakers are mounted in standard wall-mount position. The minimum inrush pulse tolerance handling capability is times the rated current. These values are based on a 0 z / cycle,. ms pulse. Instantaneous AC DC Ultrashort Short

11 -Series Time Delay Values Medium AC DC ong Short igh Inrush AC igh Inrush DC Medium ong

12 -Series andle Actuator Ordering Scheme A B 0 0 B D C Series Actuator Poles Circuit Aux/Alarm Switch Frequency & Delay Current Rating Terminal 9 Actuator Color & egend 0 Mounting Bezel/Barrier Rating Agency Approval SERIES ACTUATOR A andle, one per pole B andle, one per unit TERMINA Push ON 0.0 Tab (Q.C.) Screw - w/upturned lugs Screw - (bus type) A Screw M w/upturned lugs B Screw M (bus type) R S T Printed Circuitboard Terminals 90 Facing eft 90 Facing Right Straight Straight, ong POE One Two Three CIRCUIT A Switch Only ( coil) B Series Trip (current) AUXIIARY/AARM SWITC 0 w/o Aux Switch 0.0 Q.C. term 0.0 Solder ug FREQUENCY & DEAY 0 DC 0/0z, Switch Only 0 DC Instantaneous DC Ultra Short DC Short DC Medium DC ong 0 0/0z Instantaneous 0/0z Ultra Short 0/0z Short 0/0z Medium 0/0z ong C G Series Trip (voltage) Relay Trip (voltage) 0.0 Q.C. term w/ gold contacts 0.0 PC term 0 DC, 0/0z, Instantaneous DC, 0/0z,Ultra Short DC, 0/0z, Short DC, 0/0z, Medium DC, 0/0z, ong 0/0z Short, i-inrush 0/0z Medium, i-inrush 0/0z ong, i-inrush DC Short, i-inrush DC Medium, i-inrush DC ong, i-inrush 9 ACTUATOR COOR & EGEND Actuator Color Red Green Blue Yellow Orange I-O A C F K M P R ON-OFF B D G J N Q S 0 MOUNTING/BARRIERS MOUNTING STYE A B C D Threaded Insert BARRIERS MAX. APPICATION RATING A DC D 0AC M 0DC Dual BEZE domed domed domed domed flat flat flat flat egend Color 0VDC/0VAC CURRENT RATING (AMPERES) CODE AMPERES VOTAGE RATING CODE RATING TRIP VOTS A0 DC DC A DC 0DC A DC DC A DC 0DC A DC DC A DC 0DC A DC DC J0 AC AC J AC 0AC J AC AC J AC 0AC J AC 0AC J AC AC K0 0AC AC 0 0AC 0AC B0 0DC 9DC B0 0DC DC AGENCY APPROVA A Without approvals C U Recognized, CSA Accepted, CCC Certified E U Recognized, CSA Accepted, TUV Certified U Recognized, CSA Accepted, TUV Certified, CCC Certified Notes: Actuator Option A: handle tie pin, spacer & retainers provided unassembled on multipole units. Actuator Option B: andle location as viewed from front of panel: pole: left pole; pole: center pole Standard multipole units have all poles identical, except when specifying auxiliary switch Auxiliary switch available on Series Trip and Switch Only circuits to A. On multipole units, only one aux. switch is rmally supplied, mounted in extreme right pole. Separate Pole Type Voltage Coils t rated for continuous duty. Available only with delay code 0 & 0. Only Available w/ Agency code C. For other current ratings, consult factory. -A Polarity sensitive, only available as pole unit. Voltage code available to A max.

13 -Series Curved Rocker Actuator Ordering Scheme J B B D C Series Actuator Poles Circuit Aux/Alarm Switch Frequency & Delay Current Rating Terminal 9 Actuator Color & egend 0 Mounting Bezel/Barrier Rating Agency Approval SERIES (VISI ROCKER) ACTUATOR J Vertical - Indicate OFF K Vertical - Indicate ON TERMINA Push ON 0.0 Tab (Q.C.) Screw - w/upturned lugs Screw - (bus type) A Screw M w/upturned lugs B Screw M (bus type) R S T Printed Circuitboard Terminals 90 Facing eft 90 Facing Right Straight Straight, ong POE One Two Three CIRCUIT A Switch Only ( coil) B Series Trip (current) AUXIIARY/AARM SWITC 0 w/o Aux Switch 0.0 Q.C. term 0.0 Solder ug FREQUENCY & DEAY 0 DC 0/0z, Switch Only 0 DC Instantaneous DC Ultra Short DC Short DC Medium DC ong 0 0/0z Instantaneous 0/0z Ultra Short 0/0z Short 0/0z Medium 0/0z ong CURRENT RATING (AMPERES) CODE AMPERES VOTAGE RATING CODE RATING TRIP VOTS A0 DC DC A DC 0DC A DC DC A DC 0DC A DC DC A DC 0DC C G Series Trip (voltage) Relay Trip (voltage) 0.0 Q.C. term w/ gold contacts 0.0 PC term 0 DC, 0/0z, Instantaneous DC, 0/0z,Ultra Short DC, 0/0z, Short DC, 0/0z, Medium DC, 0/0z, ong 0/0z Short, i-inrush 0/0z Medium, i-inrush 0/0z ong, i-inrush DC Short, i-inrush DC Medium, i-inrush DC ong, i-inrush A DC DC J0 AC AC J AC 0AC J AC AC J AC 0AC J AC 0AC J AC AC K0 0AC AC 0 0AC 0AC B0 0DC 9DC B0 0DC DC 9 ACTUATOR COOR & EGEND Actuator Color Red Green Blue Yellow Orange I-O A F K M P R ON-OFF B G J N Q S 0 MOUNTING/BARRIERS MOUNTING STYE A B C D E F G 9 J P K Q U M Threaded Insert BARRIERS Dual AF ROCKER GUARD BRACKET COOR MAX. APPICATION RATING A DC D 0AC M 0DC 0VDC/0VAC AGENCY APPROVA A Without approvals C U Recognized, CSA Accepted E U Recognized, CSA Accepted, TUV Certified U Recognized, CSA Accepted, TUV Certified, CCC Certified FIG.B FIG. C Notes: alf guard construction have OFF protection for actuator Standard multipole units have all poles identical, except when specifying auxiliary switch Auxiliary switch available on Series Trip and Switch Only circuits to A. On multipole units, only one aux. switch is rmally supplied, mounted in extreme right pole. Separate Pole Type Voltage Coils t rated for continuous duty. Available only with delay code 0 & 0. Only Available w/ Agency code C. For other current ratings, consult factory. On Visi-Rocker,Visi portion of rocker cant be the same color as the bezel. Remainder of rocker same color as bezel. -A Polarity sensitive, only available as pole unit. Voltage code available to A max.

14 -Series Flat Rocker Actuator Ordering Scheme B B D C Series Actuator Poles Circuit Aux/Alarm Switch Frequency & Delay Current Rating Terminal 9 Actuator Color & egend 0 Mounting Bezel/Barrier Rating Agency Approval SERIES ACTUATOR Single Color Vertical Single Color orizontal Push to Reset, Single Color Vertical Push to Reset, Single Color orizontal TERMINA Push ON 0.0 Tab (Q.C.) Screw - w/upturned lugs Screw - (bus type) A Screw M w/upturned lugs B Screw M (bus type) R S T Printed Circuitboard Terminals 90 Facing eft 90 Facing Right Straight Straight, ong POE One Two Three CIRCUIT A Switch Only ( coil) B Series Trip (current) AUXIIARY/AARM SWITC 0 w/o Aux Switch 0.0 Q.C. term 0.0 Solder ug FREQUENCY & DEAY 0 DC 0/0z, Switch Only 0 DC Instantaneous DC Ultra Short DC Short DC Medium DC ong 0 0/0z Instantaneous 0/0z Ultra Short 0/0z Short 0/0z Medium 0/0z ong CURRENT RATING (AMPERES) CODE AMPERES VOTAGE RATING CODE RATING TRIP VOTS A0 DC DC A DC 0DC A DC DC A DC 0DC A DC DC A DC 0DC C G Series Trip (voltage) Relay Trip (voltage) 0.0 Q.C. term w/ gold contacts 0.0 PC term 0 DC, 0/0z, Instantaneous DC, 0/0z,Ultra Short DC, 0/0z, Short DC, 0/0z, Medium DC, 0/0z, ong 0/0z Short, i-inrush 0/0z Medium, i-inrush 0/0z ong, i-inrush DC Short, i-inrush DC Medium, i-inrush DC ong, i-inrush A DC DC J0 AC AC J AC 0AC J AC AC J AC 0AC J AC 0AC J AC AC K0 0AC AC 0 0AC 0AC B0 0DC 9DC B0 0DC DC X0 AC special catalog # 9 ACTUATOR COOR & EGEND Actuator Color Red Green Blue Yellow Orange I-O A C F K M P R ON-OFF B D G J N Q S 0 MOUNTING/BARRIERS MOUNTING STYE A B C D E F G 9 J P K Q U M Threaded Insert BARRIERS Dual PUS-TO- RESET egend Color BRACKET COOR MAX. APPICATION RATING A DC D 0AC M 0DC 0VDC/0VAC AGENCY APPROVA A Without approvals C U Recognized, CSA Accepted, CCC Certified E U Recognized, CSA Accepted, TUV Certified U Recognized, CSA Accepted, TUV Certified, CCC Certified FIG.B FIG. C Notes: Push-To-Reset actuator shave OFF portion of rocker shrounded Standard multipole units have all poles identical, except when specifying auxiliary switch Auxiliary switch available on Series Trip and Switch Only circuits to A. On multipole units, only one aux. switch is rmally supplied, mounted in extreme right pole. Separate Pole Type Voltage Coils t rated for continuous duty. Available only with delay code 0 & 0. Only Available w/ Agency code C. For other current ratings, consult factory. On Visi-Rocker,Visi portion of rocker cant be the same color as the bezel. Remainder of rocker same color as bezel. -A Polarity sensitive, only available as pole unit. Voltage code available to A max.

G-Series. Circuit Breaker.

G-Series. Circuit Breaker. -Series Circuit Breaker Carling Technologies -Series hydraulic/magnetic circuit breakers offer the highest quality solution to your circuit protection requirements. The -Series is designed to sense over-current

More information

PB-Series. GFCI/ELCI & Panel Seal

PB-Series. GFCI/ELCI & Panel Seal PB-Series GFCI/ELCI & Panel Seal The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments.

More information

PD-Series Ground Fault Circuit Protection

PD-Series Ground Fault Circuit Protection PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

F-Series. Circuit Breaker

F-Series. Circuit Breaker F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic

More information

CX-Series. Circuit Breaker

CX-Series. Circuit Breaker CX-Series Circuit Breaker The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the breaker to safely handle high amperage and high DC voltage applications

More information

G-Series DIN-RAIL CIRCUIT BREAKER

G-Series DIN-RAIL CIRCUIT BREAKER G-Series DIN-RAIL CIRCUIT BREAKER The G-Series hydraulic-magnetic circuit breaker insures maximum protection by integrating wiping contacts for longevity; a common trip linkage between poles; a unique

More information

MS-Series. Circuit Breaker

MS-Series. Circuit Breaker MS-Series Circuit Breaker Carling Technologies MS-Series Sealed Toggle Circuit Breaker was designed and tested to operate flawlessly in the harshest of environments. Ideally suited for COTS (commercial

More information

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables JAE Series Magnetic Circuit Protectors Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables 205 207 211 213 216 217 JAE/JRE/JLE Series Hydraulic Magnetic Circuit Protectors

More information

J-Series CIRCUIT BREAKER

J-Series CIRCUIT BREAKER J-Series CIRCUIT BREAKER Designed to provide high levels of circuit protection, the J-Series is a compact, low profile hydraulic magnetic circuit breaker ideally suited for high power density applications.

More information

ER circuit breaker - Hydraulic magnetic,

ER circuit breaker - Hydraulic magnetic, ER circuit breaker - Hydraulic magnetic, Datasheet railway, high current and voltage Features Ideal for high current and high voltage applications Precise, temperature independent operation Panel mount

More information

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73 Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 perating Characteristics 73 Delay Curves 74 Specifications 76 Decision Tables 78 SIGLE

More information

AR circuit breaker - Hydraulic magnetic,

AR circuit breaker - Hydraulic magnetic, AR circuit breaker - Hydraulic magnetic, Datasheet railway, small Features Description Small hydraulic magnetic circuit breaker for railway applications to protect electronic equipment and components against

More information

AP/UP, AP/MIL Series Magnetic Circuit Protectors

AP/UP, AP/MIL Series Magnetic Circuit Protectors AP/UP, AP/MIL AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction 68 Single Pole 69 Multi-Pole 70 Configurations 72 Operating Characteristics 73 Delay Curves 74 Specifications 75 Decision Tables

More information

RBR circuit breaker - Remote operated

RBR circuit breaker - Remote operated - Remote operated Datasheet Features ON-OFF and trip indication Load shedding Energy management Compact size Automatic reset capable Choice of interface styles Panel or 35 mm rail mounting Manual operation

More information

209 Series. Magnetic Circuit Protectors

209 Series. Magnetic Circuit Protectors 29 Series Magnetic Circuit Protectors Introduction 249 Power Selector System Multi-Pole Configurations Operating Characteristics Delay Curves Specifications Decision Tables 73 75 77 79 8 82 85 87 29/29/229/249/279

More information

Renewable Energy. Circuit Breakers and Disconnects

Renewable Energy. Circuit Breakers and Disconnects Renewable Energy Circuit Breakers and Disconnects HARNESS THE POWER About Carling Technologies Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and

More information

Products :: Circuit Protection :: Thermal Circuit Breakers

Products :: Circuit Protection :: Thermal Circuit Breakers Products :: Circuit Protection :: Thermal Circuit Breakers Thermal Circuit Breaker CLB-Series CLB-Series PDF elibrary The CLB-Series is a compact, single pole, push-to-reset family of thermal circuit breakers

More information

CR circuit breaker - hydraulic magnetic,

CR circuit breaker - hydraulic magnetic, CR circuit breaker - hydraulic magnetic, Datasheet railway, compact Features Precise, temperature independent operation Panel mount Integrated auxiliary contacts (optional) Up to 6 poles configuration

More information

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59. Single Pole Circuit Protectors 55 Multi-Pole Circuit Protectors 56 Configurations 58 Operating Characteristics 59 Delay Curves 60 Specifications 61 Decision Tables 62 SINGLE POLE CIRCUIT PROTECTORS The

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 845-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-freemechanism and toggle actuation. A choice of switching characteristics

More information

L-Series. Circuit Breaker

L-Series. Circuit Breaker L-Series Circuit Breaker Carling Technologies is pleased to introduce the new L-Series Circuit Breaker, a compact, high performance breaker ideally suited for the rigors and confined spaces found in today

More information

FR circuit breaker - hydraulic magnetic,

FR circuit breaker - hydraulic magnetic, FR circuit breaker - hydraulic magnetic, Datasheet railway, very high current Features Ideal for very high current applications Precise, temperature independent operation Panel mount Integrated auxiliary

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

209/219/229/249/279 Series Magnetic Circuit Protectors

209/219/229/249/279 Series Magnetic Circuit Protectors 29/29/229/249/279 29/29/229/249/279 Series Magnetic Circuit Protectors Introduction 65 249 Power Selector System 67 Multi-Pole 69 Configurations 7 Operating Characteristics 73 Delay Curves 74 Specifications

More information

Catalog Issued 3-03 (PDF Rev )

Catalog Issued 3-03 (PDF Rev ) W6/W9 series Magnetic Hydraulic P& Circuit reakers Features Designed for the international market. UL Recognized (UL77 and UL5), CS ccepted and VDE approved. Ratings to 5 amps. Heavy duty #-32 stud connections.

More information

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet FR circuit breaker - hydraulic magnetic, railway, Datasheet very high current Features Ideal for very high current applications Precise, temperature independent operation Panel mount Integrated auxiliary

More information

Magnetic Overcurrent Circuit Breaker

Magnetic Overcurrent Circuit Breaker Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics

More information

PDR circuit breaker - Ground fault Datasheet

PDR circuit breaker - Ground fault Datasheet - Ground fault Datasheet protection device Features Blue housing 1-3 poles plus neutral 7-100mA Preciese, temperature independent operation Choise of time delays, terminals and actuator colours Application

More information

SAR & SAS Circuit Protectors

SAR & SAS Circuit Protectors SAR & SAS Circuit Protectors 280 QAS, QAL, QFS, QFL Quick-Action Fuses 282 HVS & SARPV Compact Switches for 28 Solar Power Applications SAR & SAS Circuit Protectors Applications: Typical applications include

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker Magnetic and Hydraulic-Magnetic Circuit Breaker 835-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-free - mechanism and toggle actuation. A choice of switching characteristics

More information

Carling Circuit Breakers

Carling Circuit Breakers Carling Circuit Breakers Standard Inventory Products Guide July 2016 Edition Introduction Amelec Australia Pty Ltd is pleased to introduce our new Carling Technologies' Standard Inventory Products Guide

More information

Circuit Breakers Series AM/S

Circuit Breakers Series AM/S Heinemann fi Circuit Breakers Series AM/S UL489 LISTED / MEETS INTERNATIONAL STANDARDS Heinemann fi wrote the book on the HYDRAULIC MAGNETIC CIRCUIT BREAKERS by patenting the original technology back in

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

General Specifications

General Specifications General Specifications Electrical Capacity (Resistive oad) Power evel (silver): 3A @ 125V AC or 3A @ 250V AC or 3A @ 30V C ogic evel (gold): 0.4VA maximum @ 28V AC/C maximum (Applicable Range 0.1mA ~ 0.1A

More information

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series PGFM Series GFCI Ground Fault Protection Sensing Module INTRODUCTION The LineGard PGFM GFCI Sensing Module is a ground fault or equipment leakage sensing device designed and manufactured by North Shore

More information

IAL/IUL/IEL/LEL Series Magnetic Circuit Protectors

IAL/IUL/IEL/LEL Series Magnetic Circuit Protectors IAL/IUL/IEL/LEL IAL/IUL/IEL/LEL Series Magnetic Circuit Protectors Introduction 29 Single & Multi-Pole 3 Rocker, Sealed Toggle 32 Configurations 36 perating Characteristics 4 Delay Curves 4 Specifications

More information

General Purpose US Fuses

General Purpose US Fuses SMARTSPOT with Maximum circuit protection Amp-trap 2000 SmartSpot AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides

More information

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1 Power PCB Relay Creepage distance of 8.0 mm (0.31 in) min. between coil and contact Dual-winding latching type available Plug-in and quick-connect terminals available High sensitivity (360 mw) and high

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

AP/UP, AP/MIL Series Magnetic Circuit Protectors

AP/UP, AP/MIL Series Magnetic Circuit Protectors AP/UP, AP/MIL AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction 77 Single Pole 78 Multi-Pole 79 Configurations 8 Operating Characteristics 82 Delay Curves 83 Specifications 84 Decision Tables

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

IAX/LUX/LEX Series Low-Depth, Hydraulic-Magnetic Circuit Breakers. Introduction Configurations Delay Curves Operating Characteristics Decision Tables

IAX/LUX/LEX Series Low-Depth, Hydraulic-Magnetic Circuit Breakers. Introduction Configurations Delay Curves Operating Characteristics Decision Tables IAX/LUX/LEX Series Low-Depth, Hydraulic-Magnetic Circuit Breakers Introduction Configurations Delay Curves Operating Characteristics Decision Tables 23 24 27 28 29 IAX/LUX/LEX Series Low-Depth, Hydraulic-Magnetic

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Designed small, 2- and 3-pole types break 5 A loads and 4-pole type, 3 A load High reliability, long life Ultra-high sensitivity with quick response High vibration/shock resistance

More information

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute NRBM circuit breakers are the largest in rated current (A to 50A) among the IDEC circuit breakers series. These small sized, high-effi ciency breakers offer a variety of protection characteristics that

More information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

DD Frame - Series Circuit Breakers

DD Frame - Series Circuit Breakers The DD Frame is a compact yet very powerful circuit breaker. Using the hydraulic-magnetic technology which ensures that the breaker performance is unaffected by ambient temperature, the CI DD Frame series

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

Rotary Potentiometer. 1/2 Watt, Composition. Electrocomponents. Industrial 24mm Diameter. Rotary Potentiometer. Features

Rotary Potentiometer. 1/2 Watt, Composition. Electrocomponents. Industrial 24mm Diameter. Rotary Potentiometer. Features Electrocomponents Series 450 Data Sheet Rotary Potentiometer Industrial 4 Diameter 1/ Watt, Composition Rotary Potentiometer Features - Bushing - Twist or Bend Tab - Snap-in PC Bracket - PC Terminal Electrical

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN Safety Interlock Switches D4B- N D4BN Safety Limit Switch Snap-action contact with certified direct operation. mechanism (NC contacts only) added to enable contacts when faults occur, such as fused contacts.

More information

Sealed Pushbutton Switches

Sealed Pushbutton Switches For application help: call 1-800-537-945. Honeywell MICO SWITCH Sensing and Control 113 meet high-performance needs for rugged, compact size sealed switches that are exposed to water, oil, cleaning solvents,

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

Circuit Protectors CP31F, 32F, 33F

Circuit Protectors CP31F, 32F, 33F CP3F, 32F, 33F CP-F slim type circuit protectors 20V AC/6V DC (-pole) 0.A to 30A 20V AC/2V DC (2-pole) 0.A to 30A 20V AC (3-pole) 0.A to 30A Description FUJI's compact and high-performance CP-F series

More information

Ordering Information. Text PCB Power Relay G5LE

Ordering Information. Text PCB Power Relay G5LE A Cubic, Single-pole 10-A Power Relay Single-pole 10A 35VDC, 0.8mm contact gap: G5LE-G Single-pole 16A 250VAC: G5LE-E ROHS compliant. Sub-miniature sugar cube relay with universal terminal footprint. Conforms

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of single pole, double pole with single pole protection,

More information

Electromagnetic Industries LLP

Electromagnetic Industries LLP GROUND FAULT CURRENT DETECTION GFM Relay (Model 252 & 262) The GFM system is designed for electrical protection, not for personnel protection Application: These Class 1 (Model GFM) Ground Fault protection

More information

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact

More information

F-Series General Specifications

F-Series General Specifications arling F-Series General Specifications F-Series breakers are available up to 700, and are also available with a 25 millivolt metering shunt construction. This optional construction provides a safe method

More information

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute RA Series RA Series Key features of the RA series include: Available in 5 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over 0,000 operations

More information

Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies

Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies Standard Series Standard Series Switching Part Numbers Part Number Item Watts Rated Voltage Rated Current -A V DC 1.A -A 7. V DC.6A -A24 24V DC.3A -B V DC 2.A Key features of the standard series include:

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Typical UL1077 Application

Typical UL1077 Application Altech UL77 Typical UL77 Application Control Circuit of a UL508A Panel Disclaimer: This is just an example application. Installation should be done by a qualified electrician under the guidance of UL/NEC

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED A240R/A480R/A072F/A072B MED. VOTAGE FUSES / R-RATED R-RATED MOTOR STARTER FUSES Amp-trap R-rated fuses are current-limiting, high interrupting rating fuses intended for the short-circuit protection of

More information

Table of Contents. HCC Contactor Nomenclature

Table of Contents. HCC Contactor Nomenclature Table of Contents HC HCC SERIES: Definite Purpose Contactors... Page 1 Auxiliary Switches & Termination Drawings HCC SERIES: 1 & Pole Definite Purpose Contactors... Page 0 HCC SERIES: & Pole Definite Purpose

More information

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

Section. Circuit Breakers   Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series... Section Selection Guide...-2 RA Series...-3 RBM Series...-3 RC Series...-20 General Instructions...-29 Internal Circuit Overview...-29 for more information on this product family visit www.idec.com/circuitbreaker

More information

CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS

CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS Circuit protectors Circuit protectors Air circuit breakers Air circuit breakers AFaC and BaC types HRC fuses BLC, CR and CS types Super Rapid Fuses

More information

UL248 North American Low Voltage Fuses

UL248 North American Low Voltage Fuses UL248 North American Low Voltage Fuses UL198 : Old low voltage fuse standards UL standards UL248 : New old voltage fuse standards UL512 : Fuse block standards 2/ 23 They establish : UL standards The dimensional

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC Power PCB Relay G6D-ASI Reduced board space ideal for high-density mounting (45% smaller than the surface area of G6B). Slim package: measures 6.5 W x 17.5 L x 12.5 H mm Switches loads up to 5 A, 250 VAC/30

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker -F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 694 with trip free mechanism) offering the choice of single

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

XMC0 Series. Definite Purpose Contactors

XMC0 Series. Definite Purpose Contactors Description American Zettler XMC0 series of are electromechanical switching devices designed ideally for the HVAC industry. The most common applications of our contactors are found in refrigeration, air

More information

22AF 40AF AF 150AF 225AF 400AF 800AF

22AF 40AF AF 150AF 225AF 400AF 800AF Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug

More information

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12). Low Signal Relay High sensitivity can be driven by digital circuits Low-profile design allows use in 12.70 mm (0.50 in) PC board rack Surge withstand voltage meets FCC Part 68 regulation Units can be mounted

More information

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

PCB Relay. Contact form Terminal Single-side stable Single-winding latching PCB Relay Subminiature, Sensitive SPDT Signal Switching Relay High sensitivity: 98 mw pickup coil power. Impulse withstand voltage meets FCC Part 68 requirements. Plastic-sealed construction. Unique moving

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A PCB Relay Miniature Single-pole Relay with 80-A Surge Current and 20-A Switching Current Ideal for motor switching. Miniature, relay with high switching capacity built-in applications. Creepage distance

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive Characteristics Full face or spot illumination with incandescent lamps or multi-element LEDs, with or without resistors. Short Body Pushbuttons Series YB Choice of super bright LEDs in white,

More information

9000 SERIES SUBMINIATURE MOMENTARY PUSHBUTTON SWITCHES Overview

9000 SERIES SUBMINIATURE MOMENTARY PUSHBUTTON SWITCHES Overview A 9000 SERIES Overview 9 SERIES Number of poles 3 Single pole Electrical functions 2 Normally closed (NC) 3 Normally open (NO) Terminals, case and bushing Case height 8 (.314) 2 Straight terminals - threaded

More information

C&K ET Series Sealed Subminiature Rocker Switches

C&K ET Series Sealed Subminiature Rocker Switches Features/Benefits Sealed against solder and cleaning process contaminants, bushing & case UL 94V-0 Small footprint saves space RoS compliant Typical Applications Telecommunications Instrumentation Computers

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489 MINIATURE CIRCUIT BREAKERS SU200M Datasheet Branch protection acc. to CSA C22.2 No.5 / UL 489 The miniature circuit breaker SU200 M is ABB s solution for UL 489 branch circuit protection up to 480 Y/277

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

General Specifications

General Specifications General Specifications Electrical Capacity (Resistive oad) Power evel (silver): A @ 25/250V AC or A @ 30V C ogic evel (gold): 0.VA maximum @ 28V AC/C maximum (Applicable Range 0.mA ~ 0.A @ 20mV ~ 28V)

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

QF(13) - Series Miniature Circuit Breakers

QF(13) - Series Miniature Circuit Breakers DIN Mount 1 pole DIN Mount 2 pole Dual Mount 3 pole Dual Mount 3 + N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent of ambient temperature One, two, three, four

More information

4. Heavy duty Silver Metal Oxide contacts to provide long electrical endurance.

4. Heavy duty Silver Metal Oxide contacts to provide long electrical endurance. XMC0 Series Definite Purpose Contactors Description Hongfa s Definite Purpose Contactor XMC0 meets the rigorous demands of the HVAC, refrigeration, heating, data processing, welding, elevators, hoist &

More information

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers Supersedes October 2013 photovoltaic circuit breakers Contents Description Page Product description........................ 1 PVGard 600 Vdc........................... 2 Technical data...........................

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

BY Series 4 Tumbler Value Added Security Switchlocks

BY Series 4 Tumbler Value Added Security Switchlocks 4 Tumbler Value Added Security s Features/Benefits Anti-static switch Removable lock core atch pawl option Snap-together assembly Typical Applications Computers Point-of-sale terminals Postal equipment

More information

High Performance Thermal-Magnetic Circuit Breakers 410/520/

High Performance Thermal-Magnetic Circuit Breakers 410/520/ High Performance Thermal-Magnetic Circuit Breakers 0/0/30-... Description Single, double and three pole high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism

More information

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised: File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,

More information

Thermal-Magnetic Circuit Breaker M1-...

Thermal-Magnetic Circuit Breaker M1-... Thermal-Magnetic Circuit Breaker 320-...-M-... Description Two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 6034). The addition of a magnetic tripping

More information