1 Catalogue of Accessories
2 Room Controller with CO 2 Sensor 3 CO 2 Sensor 4 F7 Filter 400 x 220 x 48 mm 5 Carbon Filter 6 Design valve circle 7 (for pipes Ø 100, 125 and 160) Design valve square 8 (for pipes Ø 100, 125 and 160) Wall Grill Cover, white 216 x (circular holes Ø 10) Wall Grill Cover, white 216 x (circular holes Ø 5) Wall Grill Cover, white 216 x (square holes 10 x 10) Wall Grill Cover, white 216 x (square holes 5 x 5) Floor Grid - Steel 13 Ceiling/Wall Grill 14 Ceiling or Wall Air Diffuser - Plastic Ø 125mm 15 (version also for Ø 100, Ø 150, Ø 200) Facade Box 16 Doubled Facade Box Vertical - Upper 17 Double Facade Box Vertical - Lower 18 Doubled Facade Box Horizontal - Left 19 Doubled Facade Box Horizontal - Right 20 EPP Pipe System 21 Flexible Plastic Pipe DN 90/DN 75 AB 22 Distribution Box Direct Single Row 1 x 150/8 x Distribution Box Direct Single Row 1x 150/10 x Distribution Box Direct Double Rowed 1 x 150/8 x Distribution Box Direct Double Row 1 x 150/10 x Air Flow Control Valve Ø (version also for Ø 75) Register Boot Straight 90/ (version also for 75/125) Register Boot Straight 2 x 75/250 x Register Boot 1 x 90/250 x Register Boot 2 x 90/250 x (version also for 2 x 75/250 x 100) Register Boot Straight 1 x 90/250 x Register Boot - Plastic 1 x 90/1 x Register Boot 1 x 90/1 x Register Boot 1 x 90/1 x with Noise Silencer connected 1 x Ø 100/1400 Register Boot 2 x 90/1 x (version also for 2 x 75/1 x 125) Register Boot 2 x 90/1 x with Noise Silencer connected 2 x Ø 100/1400 Register Boot 2 x 75/1 x with Noise Silencer connected 2 x Ø 80/1400 Perforated Strap (reel 10 m) 45 Elbow Ø 90/90º 46 (version also for Ø 75/90º) "Y" Shaped Component 90 x 75 x Flexible Plastic Pipe DN 90/DN Flexible Pipe Connector Ø (version also for Ø 75) Distribution Box 1 x 150/6 x Distribution Box 1 x 150/8 x Distribution Box 1 x 150/12 x Distribution Box 1 x 150 (350 x 350)/12 x (version also for 1 x 150 (300 x 300)/12 x 75) JABLOTRON LIVING TECHNOLOGY s.r.o. Holešovská 1692, Holešov, Czech Republic VEN2018/05/2 Tel: info@jablotronlt.com Web: JABLOTRONLT.COM
3 OCO2 Room Controller with CO 2 Sensor Controller with CO 2 Sensor - NDIR C0 2 Sensor for detection of carbon dioxide content in rooms with variable occupancy Measuring range The C0 2 measuring range is ppm. A section of this value is converted using two parameters to %, which is then shown on the display, for example ppm is equivalent to % (air quality) or % (pollution). The Modbus also shows the absolute value in ppm. The parameters are set by direct entering in the Modbus registers. The default values are 0 % ppm (clean air), 100 % ppm (highest pollution). Auto-calibration The precision of the sensors may be reduced by transport vibrations and ageing. During operation, the sensor continuously monitors the minimum measurement and assumes a drop in the C0 2 concentration to the level of concentration in the outdoor air (400 ppm) at least once every 8 days. The lowest measured value is assigned a concentration of 400 ppm. The auto-calibration algorithm does not work in a case where the room is occupied continuously, or no drop in the concentration occurs (for example, greenhouses). In such case, it is possible to deactivate the function by direct entering in the Modbus table. In default settings, auto-calibration is active. CO 2 measuring range CO 2 measuring method CO 2 measuring precision Cover Technical data 0 to 5000 ppm (secondary outlet %) NDIR (Non-dispersive Infra Red) ±50 ppm, ±3 % of the measured value (defined under conditions of at least 3 completed ACDLs in the preceding 3 weeks), C0 2 measurement response time (90 %) 90 seconds, warm-up time 2 minutes, ACDL (automatic calibration in dimming light mode), correction of C0 2 measurement IP20
4 SCO2 CO 2 Sensor Room CO 2 Sensor - NDIR C0 2 Sensor for detection of carbon dioxide content in rooms with variable occupancy. Measuring range The C0 2 measuring range is ppm. A section of this value is converted using two parameters to %, which is then shown on the display, for example ppm is equivalent to % (air quality) or % (pollution). The Modbus also shows the absolute value in ppm. The parameters are set by direct entering in the Modbus registers. The default values are 0% ppm (clean air), 100 % ppm (highest pollution). Auto-calibration The precision of the sensors may be reduced by transport vibrations and ageing. During operation, the sensor continuously monitors the minimum measurement and assumes a drop in the C0 2 concentration to the level of concentration in the outdoor air (400 ppm) at least once every 8 days. The lowest measured value is assigned a concentration of 400 ppm. The auto-calibration algorithm does not work in a case where the room is occupied continuously, or no drop in the concentration occurs (for example, greenhouses). In such case, it is possible to deactivate the function by direct entering in the Modbus table. In default settings, auto-calibration is active. CO 2 measuring range CO 2 measuring method CO 2 measuring precision Cover Technical data 0 to 5000 ppm (secondary outlet %) NDIR (Non-dispersive Infra Red) ±50 ppm, ±3 % of the measured value (defined under conditions of at least 3 completed ACDLs in the preceding 3 weeks), C0 2 measurement response time (90 %) 90 seconds, warm-up time 2 minutes, ACDL (automatic calibration in dimming light mode), correction of C0 2 measurement IP20
5 F7F F7 Filter 400 x 220 x 48 mm Characteristics The F7 filter class according to EN 779 for fine dust; the filter is designed for holding particles of size 1-3 microns. It is applied to achieve higher indoor quality requirements and is effective against bacteria, cement dust and partly against soot or tobacco smoke.
6 CF Carbon Filter Characteristics A Carbon Filter can be added in order to despose gaseous pollutants. The Carbon used inside of the filter eliminates undesireble odors.
7 SVK100, SVK125, SVK160 Design valve circle (for pipes Ø 100, 125 and 160) Characteristics Design valve AIR DESIGN GLASS from Czech manufacturer SETRITE s.r.o. Valve intended for attachment to a wall or ceiling for air intake or outflow. The valve consists of two parts: the body of the valve and the glass front plate (shape: circle or square). The body of the valve is fitted within a system of piping by three metal springs. The glass front plate is attached to the body of the valve using springs. Dimensions Pipe diameter Body diameter Exterior diameter Body depth Diameter of the valve cap , (170) diameter of the valve cap Body diameter exterior diameter Body depth Color variants - shine Color variants - matt M 1002M 1003M 1004M 1015M 7013M M 8615M 8815M 9003M 9005M 9010M
8 SVC100, SVC125, SVC160 Design valve square (for pipes Ø 100, 125 and 160) Characteristics Design valve AIR DESIGN GLASS from Czech manufacturer SETRITE s.r.o. Valve intended for attachment to a wall or ceiling for air intake or outflow. The valve consists of two parts: the body of the valve and the glass front plate (shape: circle or square). The body of the valve is fitted within a system of piping by three metal springs. The glass front plate is attached to the body of the valve using springs. Dimensions Pipe diameter Body diameter Exterior diameter Body depth Diameter of the valve cap , (170) diameter of the valve cap Body diameter exterior diameter Body depth Color variants - shine Color variants - matt M 1002M 1003M 1004M 1015M 7013M M 8615M 8815M 9003M 9005M 9010M
9 MI216174K10 The final design can be modified on demand (stainless steel colour according to the RAL colour swatch) Wall Grill Cover, white 216 x 174 (circular holes Ø 10)
10 MI216174K5 The final design can be modified on demand (stainless steel colour according to the RAL colour swatch) Wall Grill Cover, white 216 x 174 (circular holes Ø 5)
11 MI216174C1010 The final design can be modified on demand (stainless steel colour according to the RAL colour swatch) Wall Grill Cover, white 216 x 174 (square holes 10 x 10)
12 MI216174C55 The final design can be modified on demand (stainless steel colour according to the RAL colour swatch) Wall Grill Cover, white 216 x 174 (square holes 5 x 5)
13 MIPO Floor Grid - Steel
14 MISS Ceiling/Wall Grill
15 TVP125 Ceiling or Wall Air Diffuser - Plastic Ø 125mm (version also for Ø 100, Ø 150, Ø 200)
16 FBOX150 The final design can be modified on demand (stainless steel colour according to the RAL colour swatch) Facade Box
17 FBOXSS150HV The final design can be modified on demand (stainless steel colour according to the RAL colour swatch) Doubled Facade Box Vertical - Upper
18 FBOXSS150SV The final design can be modified on demand (stainless steel colour according to the RAL colour swatch) Double Facade Box Vertical - Lower klik
19 FBOXHS150LV The final design can be modified on demand (stainless steel colour according to the RAL colour swatch) Doubled Facade Box Horizontal - Left
20 FBOXHS150PV The final design can be modified on demand (stainless steel colour according to the RAL colour swatch) Doubled Facade Box Horizontal - Right
21 EPP EPP Pipe System Properties The EPP Pipe System is an innovative, self-supporting system resistant to moisture. It uses a unique connecting principle thanks to which its installation is quick and clean. The pipe system fulfils the requirements of EnEV 2009 for insulation of the air channels in the ventilation system and is installed as a substitute for spiro pipes. The pipe system is available in sizes of DN 150/210. The pipe itself is made of two parts. Thanks to material with a high-density material and thickness of insulation, it has excellent thermal insulation properties. Installation Installation must be done in compliance with the provisions of the building regulations of the given country. The manufacturer s product warranty is two years, which applies to defective material. Use Used for intake of fresh air and extraction of spent air between the outdoor environment and the recuperation unit. It is designed for use in the interior environment. The insulating pipe system is designed for up to 200 Pa and is air-tight. We recommend using max. 375 m 3 /h. We recommend use of melting wire to shorten the pipe. Caution: The latch must be installed horizontally. The pipe must have hangers at distances of min. 1 m. The pipe system is self-supporting according to DIN with material class B2. Pipe length: Outer diameter: Inner diameter: 1000 mm 210 mm 150 mm
22 FLEXIAB Flexible Plastic Pipe DN 90/DN 75 AB The PE Flexible Plastic Pipe for HVAC systems built using composite pipe technology according to ČSN ensures transport of air during its exchange with low pressure loss. The inner wall of the pipe has anti-bacterial and anti-fungal protection. Coil 50 m. Area of application Pipe material and colour The flexible plastic pipe can be used for supply of air to and removal of air from rooms using central devices for control of the ventilation of swelling spaces. Outer PE-HD layer (green), inner PE-LD layer (transparent or dark grey) + anti-bacterial and anti-fungal additive Physical characteristics Material PE E-Module [MPa] DIN ISO 527-1/-2 Impact stiffness [kj/m] DIN ISO 179-1eU Tensile strength [MPa] DIN ISO 527-1/-2 Elongation at break [%] DIN ISO 527-1/-2 Specific passage resistance [Ω cm] DIN IEC Surface resistance [Ω] DIN IEC Flammability UL 94 Chemical resistance Permits / Standards PE is resistance to almost all media (alcohols, fats, mineral oils, propellant fuels). The PE structure is disrupted only by high-oxidation acids. The pipes of given nominal diameters fulfil the requirements of ČSN EN Pressure test 450N. Anti-bacterial test done according to ČSN EN ISO 846:98, method A, C. Dimensions and packaging DN [mm] Outer diameter [mm] Inner diameter [mm] Packaging [m] Air supply DN 75 Air supply DN 90 Air-flow rate 2 m/s 2,5 m/s 3 m/s 4 m/s 21 m 3 /h 26,3 m 3 /h 31,6 m 3 /h 42 m 3 /h Air-flow rate 2 m/s 2,5 m/s 3 m/s 4 m/s 31,8 m 3 /h 39,8 m 3 /h 47,7 m 3 /h 63,6 m 3 /h
23 FLEXI Flexible Plastic Pipe DN 90/DN 75 The PE flexible plastic pipe for HVAC systems built using composite pipe technology according to ČSN ensures transport of air during its exchange with low pressure loss. The inner wall of the pipe has anti-bacterial and anti-fungal protection. Coil 50 m. Area of application Pipe material and colour Chemical resistance The flexible plastic pipe can be used for supply of air to and removal of air from rooms using central devices for control of the ventilation of swelling spaces. Outer PE-HD layer (blue), inner PE-LD layer (dark grey). PE is resistance to almost all media (alcohols, fats, mineral oils, propellant fuels). The PE structure is disrupted only by high-oxidation acids. Physical characteristics Material PE E-Module [MPa] DIN ISO 527-1/-2 Impact stiffness [kj/m] DIN ISO 179-1eU Tensile strength [MPa] DIN ISO 527-1/-2 Elongation at break [%] DIN ISO 527-1/-2 Specific passage resistance [Ω cm] DIN IEC Surface resistance [Ω] DIN IEC Flammability UL 94 Dimensions and packaging Permits / Standards The pipes of given nominal diameters fulfil the requirements of ČSN EN Pressure test 450N. DN [mm] Outer diameter [mm] Inner diameter [mm] Packaging [m] Air supply DN 75 Air supply DN 90 Air-flow rate 2 m/s 2,5 m/s 3 m/s 4 m/s 21 m 3 /h 26,3 m 3 /h 31,6 m 3 /h 42 m 3 /h Air-flow rate 2 m/s 2,5 m/s 3 m/s 4 m/s 31,8 m 3 /h 39,8 m 3 /h 47,7 m 3 /h 63,6 m 3 /h
24 SF90 Flexible Pipe Connector Ø 90 (version also for Ø 75)
25 RB Distribution Box 1 x 150/6 x 90
26 RB Distribution Box 1 x 150/8 x 90
27 RBBR Distribution Box 1 x 150/12 x 75
28 RBBR Distribution Box 1 x 150 (350 x 350)/12 x 90 (version also for 1 x 150 (300 x 300)/12 x 75)
29 RBPJ Distribution Box Direct Single Row 1 x 150/8 x 90
30 RBPJ Distribution Box Direct Single Row 1x 150/10 x 90
31 RBPD Distribution Box Direct Double Rowed 1 x 150/8 x 90
32 RBPD Distribution Box Direct Double Row 1 x 150/10 x 90
33 RK90 Air Flow Control Valve Ø 90 (version also for Ø 75)
34 VKP90125 Register Boot Straight 90/125 (version also for 75/125)
35 VKRP Register Boot Straight 2 x 75/250 x 100
36 VKR Register Boot 1 x 90/250 x 100
37 VKR Register Boot 2 x 90/250 x 100 (version also for 2 x 75/250 x 100)
38 VKRP Register Boot Straight 1 x 90/250 x 100
39 VK P Register Boot - Plastic 1 x 90/1 x 125
40 VKR Register Boot 1 x 90/1 x 125
41 VKR STH Register Boot 1 x 90/1 x 125 with Noise Silencer connected 1 x Ø 100/1400
42 VKR Register Boot 2 x 90/1 x 125 (version also for 2 x 75/1 x 125)
43 VKR STH Register Boot 2 x 90/1 x 125 with Noise Silencer connected 2 x Ø 100/1400
44 VKR STH Register Boot 2 x 75/1 x 125 with Noise Silencer connected 2 x Ø 80/1400
45 DZP10P Perforated Strap (reel 10 m)
46 OB9090 Elbow Ø 90/90º (version also for Ø 75/90º)
47 KK "Y" Shaped Component 90 x 75 x 75
EGQ 212: Duct transducer, CO 2 and temperature
Product data sheet 7.0 EGQ : Duct transducer, CO and temperature How energy efficiency is improved Measuring the CO concentration and temperature for energy-efficient, demand-controlled regulation of the
More informationOperating voltage 120, 230 V AC Air volume 24 m³/h (14.1 CFM) Rated power 13 W Size 1
7F Series - Filter Fan (24 500) m³/h (14.1...294.3) CFM 7F Features 7F.50.8.xxx.1020 7F.50.8.xxx.2055 7F.50.8.xxx.3100 Filter Fan for electrical cabinets and enclosures 120 V or 230 V AC versions Very
More informationPLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES
PLENUM WITH ABSOLUTE FILTER HOLDER FOR SUPPLY GRILLES TECHNICAL CHARACTERISTICS PP30 OVERVIEW : The PP 30F (rear connection) and PP 31F (lateral connection) are employed for the diffusion of air using
More informationAir volume 24 m³/h (14.1 CFM) Rated power 13 W Size (14.1) 55 (32.4) 100 (58.9) Air volume (with exhaust filter installed)
Series - Filter Fan (24 500) m³/h (14.1...294.3) CFM 7F 7F.50.8.XXX.1020 7F.50.8.XXX.2055 7F.50.8.XXX.3100 Filter Fan for electrical cabinets and enclosures 230 V or 120V AC versions Very low acoustic
More information1. Description Design Front panels - vanes setting Flow directions Dimensions and weights... 8
These technical specifications state a row of manufactured sizes and versions of whirling air outflow outlets VVDM 300, 400, 500, 600, 625 und 825 (further only outlets). It is valid for production, designing,
More informationSafety drying ovens with expanded temperature range
MDL series 115 Safety drying ovens Safety drying ovens with expanded temperature range The BINDER MDL, with enhanced control function, works at temperatures up to 350 C (662 F). It is it perfectly suited
More informationSafety drying oven with expended temperature range
MDL series 115 Safety drying ovens Safety drying oven with expended temperature range The BINDER MDL 115 with enhanced control function works at temperatures up to 350 C. This safety drying oven meets
More informationHeating chamber with mechanical convection
FED series 240 Drying ovens / Heating ovens Heating chamber with mechanical convection The multi-talented BINDER heating chamber of the FED series provides almost unlimited capacity and is particularly
More informationHeating chamber with mechanical convection
FED series 720 Drying ovens / Heating ovens Heating chamber with mechanical convection The multi-talented BINDER heating chamber of the FED series provides almost unlimited capacity and is particularly
More informationSafety drying ovens. Advantages: Areas of application: FDL series 115
FDL series 115 Safety drying ovens Safety drying ovens The BINDER FDL with silicone and dust-free inner chamber, as well as symmetric airflow dries specimens containing solvents perfectly and thus meets
More informationiglidur G The General Purpose Bearing
iglidur The eneral Purpose Bearing Most popular iglidur material worldwide. iglidur bearings cover an extremely wide range of different requirements they are truly all round. Typical applications cover
More informationHeating chamber with mechanical convection
FED series 53 Drying ovens / Heating ovens Heating chamber with mechanical convection The multi-talented BINDER heating chamber of the FED series provides almost unlimited capacity and is particularly
More informationHeating chamber with mechanical convection
FED series 53 Drying ovens / Heating ovens Heating chamber with mechanical convection The multi-talented BINDER heating chamber of the FED series provides almost unlimited capacity and is particularly
More informationiglidur G The General Purpose Bearing: most popular iglidur material worldwide
Standards Wide Range from Stock polymer bearings G The General Purpose Bearing: most popular material worldwide from page 51 J The Fast and Slow Motion Specialist: used in long-life applications, also
More informationKLIMA Active Chilled Beams
KLIMA 2 600 Active Chilled Beams 0 Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Selection example 12 Guide specifications 13
More informationHAZARDOUS SUBSTANCES DRUM CABINETS
HAZARDOUS SUBSTANCES DRUM CABINETS For storage of flammable liquids in containers and drums up to 200 liters inside buildings Whole construction tested and approved by an authorized materials testing institute
More informationType DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES
Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Ceiling swirl diffusers with perforated face plate > Type DCS Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION
More informationiglidur J The Fast and Slow Motion Specialist
iglidur The Fast and Slow Motion Specialist Used in long-life applications, also with soft shafts. The iglidur plain bearings are designed for the lowest coefficients of friction while running dry and
More informationLow friction, low wear: The Fast and Slow Motion Specialist iglidur J
Low friction, low wear: The Fast and Slow Motion Specialist iglidur Over 250 sizes available from stock Low wear against different shaft materials Low coefficients of friction running dry Vibration dampening
More informationCeiling swirl diffusers with perforated face plate
X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser
More informationJUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features
Delivery address: Mackenrodtstraße 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +9 66 600-0 Fax: +9 66 600-607 Harlow, Essex CM 0 DY, UK Phone: + 79 6 55 Fax: + 79 6 50 9 67 Myers Road
More informationJUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features
Delivery address: Mackenrodtstraße 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +9 66 600-0 Fax: +9 66 600-607 Harlow, Essex CM 0 DY, UK Phone: + 79 6 55 Fax: + 79 6 50 9 67 Myers Road
More informationIEQp1 Minimum Indoor Air Quality Performance Appeal Review
Appeal Review Date: 24.3.2014 Contents 1 LEED REVIEW TEAM COMMENTS... 2 2 PROJECT TEAM RESPONSE... 2 3 PARKING EXHAUST RATE CALCULATION... 3 3.1 REFERENCED STANDARDS... 3 3.2 CALCULATION OF THE REQUIRED
More informationKSI Filtertechnik GmbH Siemensring D Willich Tel Fax
BA SIC.LINE Rev 1.0.1 Page 1 of 9 KSI Filtertechnik GmbH Siemensring 54-56 D-47877 Willich Tel. +49 21 54 89 108-0 Fax +49 21 54 89108-282 www.ksi.eu mail@ksi.eu ECOCLEAN Compressed air filters new generation
More informationTying and fixing system. Cable ties 22. raw material colour U61X U60X. Black. Natural. Grey
Tying and fixing system 22 raw material colour U61X U60X Black Natural Grey 22 U61X U60X For tying of cables and conduits Complete product family for all kind of applications. Hand thread, easier mounting
More informationSUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130
SUPPLY AND RETURN AIR GRILLES TYPE: AS/GS120 AS/GS130 Installation dimensions AS/GS120 AS/GS130 Application The grille type AS / GS is used for the supply and exhaust of cooled or heated air in facilities
More informationCG INLET CEILING. Inlet ceiling with the laminar discharge flow for operating rooms
CG INLET CEILING Inlet ceiling with the laminar discharge flow for operating rooms Pleasant climate controllable as required Economical operation due to the point protection principle Extremely low number
More informationSuitable For: Bathroom Living Area Whole House Ventilation Duct Boosting Hydroponic Growing General Ventilation
TT inline mixed type fans combine wide capabilities and excellent features of axial and centrifugal fans. The unique motor and impeller combination enables the TT fans to deliver high performance with
More informationStoves with Perfect Combustion
Stoves with Perfect Combustion HS Flamingo Wood Stoves Advantages of Wood Stoves secondary combustion (ensures clean glass and complete combustion of gaseous components thanks to special intake of secondary
More informationType ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES
Homepage > Products > Air Diffusers > Industrial diffusers > Diffusers for high momentum > Type ISH Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES Impulse diffusers with horizontal air discharge
More informationCarbon Dioxide (CO2) + Humidity (rh) + Temperature (T) transmitter with Display for room mounting. Features
Carbon Dioxide (CO2) + Humidity (rh) + Temperature (T) transmitter with Display for room mounting RCD 010 THD Oct.16 Features Carbon Dioxide (CO2) output 0-10 Vdc Humidity (rh) output 0-10 Vdc Temperature
More informationSPUN (MELT-BLOWN) POLYPROPYLENE MICRON FILTER CARTRIDGE
SPUN (MELT-BLOWN) POLYPROPYLENE MICRON FILTER CARTRIDGE Description: Spun Filter Cartridge with inner supporting Polypropylene Core is the latest development in nominal rated filter cartridge, giving longer
More informationPREMIUM PLASTIC PROTECTION PARTS
PREMIUM PLASTIC PROTECTION PARTS MATERIAL OPTIONS Consistently low prices EP 180 Pressure Pipe Protection Uniplugs for PVC pipes DN 50 DN 600 EP 190 Driveshaft Protection Caps with Fitting Key EP 200 Stud
More informationJUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.
Page /0 JUMO MIDAS S07 MA OEM Pressure Transmitter - Maritime Approved Applications In the shipping and offshore sector: HVAC (heating, ventilating, and air conditioning) Refrigeration engineering Compressors
More informationHoses for the Agricultural Industry. Hoses & Connection Systems for demanding applications in the Agricultural Industry
Hoses for the Agricultural Industry Hoses & Connection Systems for demanding applications in the Agricultural Industry Your specialist partner for any application in the Agricultural Industry As much variety
More informationCircular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/
6/5/EN/6 Circular Silencer Rigid and flexible construction Type CA CB CF CS TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn
More informationIMP Klima. Swirl diffusers. Variable swirl diffusers
Swirl diffusers Variable swirl diffusers OD-4 OD-, OD-V OD-7 OD-7 OD-9 OD-5 OD-4 KD-8 OD-8 OD-5 Dn Dz Dn Dz A x A φ A 84 4 295x295 00 0.045 92 50 95x95 0 0.00 50 450 495x495 500 0.086 70 5 595x595 600
More informationNovenco Tunnel Fans. Novax October 2007
Novenco Tunnel Fans Novax October 2007 Product facts Product Novenco tunnel fans are produced with either round or rectangular outer dimensions. Both types are made in unidirectional (AUC and AUR) and
More informationType CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION
Homepage > Products > Sound attenuators > Circular silencers > Type CS Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION Circular silencers, in rigid aluminium construction,
More informationTRACTION BATTERY CHARGER SERVICE MANUAL
AXIgo TRACTION BATTERY CHARGER SERVICE MANUAL AXIgo TRACTION BATTERY CHARGER Content 1 Basic Data... 2 1.1 Device Characteristics... 2 1.2 Usage... 2 1.3 The Marking System of the AXIgo-type chargers...
More informationProcess Inline Filter Protective filter PLF2-9HF
Process Inline Filter Protective filter PLF2-9HF Specifications Nominal size: DN 300 - DN 600 Q s max: 3000 m 3 /h p s max: 16 bar Filtration ratings: 1-90 µm 1. GENERAL Product description Protective
More informationApartment ventilation
GB1250 06.18 AuraFlex LØV-R Apartment ventilation Diffusers in steel Customer adapted diffuser pattern Available in all colours Plenum box with damper and measuring outlet for commissioning Plenum box
More informationMaximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment
Maximum Protection in Filter Systems CGF/CGG GEA Ceiling Air Outlets Data & Facts GEA Heat Exchangers / GEA Air Treatment Table of Contents Technical Description... 3 Application and Components... 3 Components...
More informationPRODUCT CATALOGUE DOUBLE PREINSULATED PIPES
PN-EN 15698-1 ITB Technical Approval AT-15-7772/2008+ Annex no.1 Validity term: September 30, 2013 Issued by the Building Research Institute in Warsaw Preinsulated Pipe System To Be Used In Buried Thermal
More informationTable of Contents COOLMANT. 2.0 Table of Contents
CLM 2.0 Table of Contents 2.0 Table of Contents 2.1 System description 2.100 System description (general) 2.105 System description (data) 2.115 COOLMANT range, Ø 125 - Ø 315 / SDR 11/SDR 17 (bars) 2.2
More informationApartment ventilation
GB1250 04.18 AuraFlex LØV-R Apartment ventilation Diffusers in steel Customer adapted diffuser pattern Available in all colours Plenum box with damper and measuring outlet for commissioning Plenum box
More informationTechnical Documentation. LTG Fine Filters. Type CDF / UDF
Technical Documentation LTG Fine Filters Type CDF / UDF LTG Fine Filters Type CDF and Typ UDF Only precise adaptation of the filter parameters to the air volume to be filtered will ensure the optimum of
More informationLow wear on all shafts: The Marathon Runner iglidur W300
iglidur Low wear on all shafts: The Marathon Runner iglidur Over 400 sizes available from stock For especially long service life Low coefficient of friction Extremely high wear resistance Also suitable
More informationseries 260 LAS 260 HD FK
series 260 Date of issue: 11/2013 Extraction. Filtration. Persistence. Use and application The is suitable for collecting and filtering dry and non-combustible types of dust contained in non-explosive
More informationACCESSORIES FOR DUCT FANS
FOR DUCT FANS Duct fan Clamp Filter box Silencer Electric heater Duct fans are mostly used in low-to medium-pressure ducted systems with additional components such as heaters, filter boxes, dampers, etc.
More informationBRIZA 22 HYBRID HEATING & COOLING
BRIZA 22 HYBRID HEATING & COOLING Built-in Ceiling: BABC/BT BABC/FT Built-in Wall: BABW/BT BABW/BF BABW/FT BABW/FF INFO SHEET BRIZA 22 HYBRID, COMPACT FANCOIL With EC Greentech EBM-PAPST technology Europe
More informationtechnical data air conditioning systems Round Flow Cassette FXFQ-P9VEB
technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................
More informationTable of Contents 2.0 COOLFLEX CLX. 2.0 Table of Contents
Table of Contents CLX 2.0 2.0 Table of Contents 2.1 System description 2.100 System description (general) 2.105 System description (data) 2.115 range, DN 20 - DN 125 / SDR 11 (coils) 2.2 Planning, design
More informationHeating oven with mechanical control
ED series 23 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C. Thanks to the
More informationDryLin R Linear Plain Bearings, Fast and Quiet
+90º 40º +250º 100º Linear Plain Bearings, Fast and Quiet linear plain bearings, made from solid polymers, are dimensionally equivalent to standard ball bearings. They are made entirely of wear resistant
More informationN O V E L T Y Diffuser with particulate filter class H13
N O V E L T Y Diffuser with particulate filter class H13 NAF Atest Higieniczny: HK/B/1121/02/2007 NAF diffusers are intended to use in low- and mediumpressure ventilation systems. They are used in facilities
More informationDryLin R Linear Plain Bearings, Fast and Quiet
+90º 40º +250º 100º Linear Plain Bearings, Fast and Quiet linear plain bearings, made from solid polymers, are dimensionally equivalent to standard ball bearings. They are made entirely of wear resistant
More informationHoneywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM
Honeywell Zephyr TM Analog Airflow Sensors HAF Series High Accuracy ±50 SCCM to ±750 SCCM Honeywell Zephyr TM Analog Airflow Sensors HAF Series - High Accuracy Honeywell Zephyr HAF Series sensors provide
More informationDryLin R Linear Plain Bearings, Fast and Quiet
+90º 40º +250º 100º Linear Plain Bearings, Fast and Quiet linear plain bearings, made from solid polymers, are dimensionally equivalent to standard ball bearings. They are made entirely of wear resistant
More informationlindab we simplify construction LindabSmoke control system single compartment Duct and fittings, Smoke control dampers Mounting instruction
lindab we simplify construction LindabSmoke control system single compartment Duct and fittings, Smoke control dampers Mounting instruction Duct and fittings Content Duct and fittings Introduction...3
More informationseries RVV Variable flow rate controllers
series RVV Variable flow rate controllers www.koolair.com Series RVV 1 CONTENTS Variable flow rate controllers, type RVV Description 2 Dimensions and product code 3 Selection tables 4 Variable flow rate
More information2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m
2/18/EN/2 Air Handling Lights Type LR Recommended for use in rooms with ceiling heights of approx. 2.60... 4.00 m Contents Description Description... 2 Supply Air Construction LR-Z... 3 Extract Air Construction
More information1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.
1. SPECIFICATION 5 GENERAL INFORMATION Motors with parameters according to the data sheet comply with the requirements of the IEC 60034-1 standard, and IEC 60034-30 class efficiency IE2 Motor versions:
More informationCircular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en
X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, aluminium construction Circular silencers, in rigid aluminium construction, for the reduction of noise in the
More information4 pole insulated conductor rails UNILIFT-ULA 35A, 50A, 80A, 100A
2 Table of contents General information... 4 Elements of the conductor rail supply line... 4 Innovative connection method... 5 Technical properties... 6 Construction of the line section... 6 Line section...
More informationGEMÜ 205 Electrically operated solenoid valve
Electrically operated solenoid valve Features Hermetic separation between medium and actuator In case of power failure operation possible by manual override Standard integral optical position indicator
More informationFIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS
FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS Rectangular fire dampers FIRE DAMPERS PL-12 PL-15 PL-18-1, PL-18-2 Fire dampers are installed in rectangular or circular ventilation ducts, at passages
More informationseries Silencers
series SK Silencers www.koolair.com Series SK 1 Silencers CONTENTS ASK-1 and ASK-2 Round Silencers Description 4 ASK-1 Overall Dimensions 5 ASK-2 Overall Dimensions 6 Selection Table and Weights 7 ASK-1
More informationC O L M A N. Air Distribution FLOOR SWIRL DIFFUSERS B SERIES SERIES
C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S FLOOR SWIRL DIFFUSERS B SERIES B SERIES B SERIES FLOOR SWIRL DIFFUSER Application: The B series floor/swirl diffusers are designed
More informationCOLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air
Square ceiling diffuser with discs for supply air QUICK FACTS Adjustable discs flexible spread pattern Can be used for vertical air diffusion Swirl function Also available in the Extract air version Designed
More informationTable of Contents. EIGERFLEX -Clima. 2.0 Table of Contents
2.0 Table of Contents 2.0 Table of Contents 2.1 System description 2.100 System description (general) 2.105 System description (data) 2.115 -Clima range, DN 20 - DN 125 / SDR 11 (coils) 2.120 -Clima range,
More informationPURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS
Homepage > Producten > Luchtroosters > Lijnroosters > Pureline18 PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with
More informationAir Zone. High Care. Cleanroom Filtration
Air Zone igh Care Cleanroom Filtration Cleanroom filtration Clean and sterile air in a cleanroom zone is provided by absolute filters. If even greater safety in terms of sterility is required, behind the
More informationHomepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM
Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM MULTI-SERVICE ACTIVE CHILLED BEAM WITH TWO-WAY AIR DISCHARGE AND HORIZONTAL
More informationDESIGN DESCRIPTION AND TECHNICAL GUIDE FOR SIDE DOOR INSTALLATION
DESIGN DESCRIPTION AND TECHNICAL GUIDE FOR SIDE DOOR INSTALLATION English SERIES SDN 2016 www.alutech-group.com Table of Contents 1 SCOPE AND CONDITIONS OF SIDE DOOR USE...5 2 SIDE DOOR COMPLIANCE WITH
More informationPSI FLANGE ISOLATION KITS
PSI LANGE ISOLATION KITS GLV-UNISEAL T GLV-UNISEAL GGR EASY INSTALLATION AND MAINTENANCE REE PERMANENTLY ELASTIC OVER THE ENTIRE SERVICE LIE HIGH STRESS RESISTANT O LOAD GASKET WWW.PSI-PRODUCTS.COM 177
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting K
.1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More information20 HUBER+SUHNER RADOX SOLAR
All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX
More informationCircular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1
X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, galvanised sheet steel construction Circular silencers Type for the reduction of noise in the circular ducts
More informationSilent centrifugal air heater hot water supply
Large range : 5 to 120 Flows : 900 to 14000 m 3 /h Numerous accessories Design integrating perfectly in public buildings USE Operation in zones ES and S Extra silent and silent Forced air heating for premises
More informationType VSD35. Nominal length up to 1500 mm: one spigot
Type VSD35 Nominal length up to 1500 mm: one spigot NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with 35 mm diffuser face (nominal width) and adjustable air control elements
More informationBatteries for Renewable Energy Applications
BAE Secura Solar Made in Germany Solar Wind Hydropower Biomass Batteries for Renewable Energy Applications BAE Secura Solar Batteries for Renewab Applications Type PVS Cells PVS Block PVV Cells Technology
More informationTechnical Data Sheet VENUS FLA SCM
VENUS FLA SCM VENUS Material Outside Material Component Material Colour Flammability Back panel ASA UV stabilized, halogen free grey, RAL 7040 UL94-HB Cover ASA UV stabilized, halogen free grey, RAL 7040
More informationInductive conductivity meter
Inductive conductivity meter CIP version Type 8228 can be combined with... Standard version Perfect for concentrated liquids and wide conductivity range Pre-parameterized versions available for direct
More informationHeating oven with natural convection
ED series 23 Drying ovens / Heating ovens Heating oven with natural convection The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C. Thanks to the
More informationWALL MOUNTED AND FREE STANDING CONVECTORS
REGISTERED OFFICE OF THE COMPANY MINIB, a.s. Střešovická 405/49, 162 00 Prague 6 Czech Republic Tel.: +420 220 180 780 Fax: +420 220 180 779 Email: office@minib.cz, www.minib.cz MANUFACTURING Manufacturing
More informationLinear Floor Grilles Models FG, F20, F25 and FRO
April 2010 Linear Floor Grilles Linear Floor Grilles Models FG, F20, F25 and FRO Features Model FG Recessed Linear Floor Grille Model F20 and F25 Flanged Linear Floor Grille Model FRO Roll Out Floor Grille
More informationDryLin R Linear Plain Bearings, Fast and Quiet
+90º 40º +250º 100º Linear Plain Bearings, Fast and Quiet linear plain bearings, made from solid polymers, are dimensionally equivalent to standard ball bearings. They are made entirely of wear resistant
More informationADAPTTM. Extract. Extract air diffuser for the WISE system. Quick Selection
ADAPTTM Extract Extract air diffuser for the WISE system Quick facts Active damper Pressure-dependent and cleanable Integrated sensor module Simple wiring, Plug & Play Communication via Modbus RTU Supplied
More informationROOF FAN ROOFMASTER STEC
AIR COMFORT AIR MOVEMENT ROOF FANS ROOF FAN ROOFMASTER STEC INSULATED VERSION» TECHNICAL CATALOGUE 2 STEC Roofmaster - Technical Catalogue CONTENTS GENERAL DESCRIPTION Application/specification... 3 Features...
More informationEnergy Supply Systems
Energy Supply Systems SINGLE POLE INSULATED CONDUCTOR RAIL 815 100 amps KAT0815-0001b-E Conductor rail system in a high bay storage Slip ring with conductor rail system in a stretch-foil packing machine
More informationVAV terminal units. Type TVM. For dual duct systems PD TVM 1
X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings
More informationDisplacement flow diffusers. L e
Displacement flow diffusers L-08-1-04e Contents Application Safety instructions Contents Application Safety instructions 2 Construction Perforation Principle of operation Example of quick selection 3 Type
More informationDCV-CF DCV-CF. DCV-CF Pressure control with airflow measuring CFL Version B03. Pressure controlwith airflow measuring. Product description
DCV-CF Pressure controlwith airflow measuring 24VAC + Communication Pressure control with airflow measuring DCV-CF DIN 24VAC + Communication AIN AOUT SMART DAMPERS & MEASURING UNITS PRESSURE & FLOW DCV-CF
More informationPELICAN Ceiling HF. Square extract air diffuser QUICK FACTS
Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with
More informationinduction Unit effective and efficient cooling, heating and ventilation
effective and efficient cooling, heating and ventilation MiniB induction Units With MiniMal energy requirements, high output and low noise. induction Unit www.minib.com 2 about us ABOUT THE COMPANY MINIB
More informationREMA TECHNICAL INFORMATION DIN 80, 160, 320. Page 1 of 13
DIN 80, 160, 320 C O N N E C T O R D A T A S H E E T Page 1 of 13 DIN 80, 160 and 320 Connector datasheet REMA is the leading supplier of DIN-style (DIN standard 43589) quick-disconnect power connectors.
More informationPolyamide 6 & 66 for Injection Moulding
Polyamide 6 & 66 for Injection Moulding Promyde is a trademark of NUREL 1 NUREL Engineering Polymers Polymerization Integrated into In-House Compounding 50 years experience in polymerization processes
More informationsomething new in the air Technical Bulletin
something new in the air Technical Bulletin 2 Air Leaf 2 Air Leaf 3 Innova is a company operating in the renewable energy sector and develops advanced climatic comfort systems for every season. The technological
More informationPolyamide 6 for Injection Moulding
Polyamide 6 for Injection Moulding Promyde is a trademark of NUREL 1 NUREL Engineering Polymers Excellence in Polymerization Recent technical advancements in NUREL polymerization processes have enabled
More information