V

Size: px
Start display at page:

Download "V"

Transcription

1 4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT R set by hand or by optional RCU (Remote Control Unit) X 65 R2 X 65 4-Port Antenna / 65 / /17.5dBi 0 8 /0 8 T Type No V01 Lowbands R1; R2 Frequency range MHz Polarization +45, , , 45 Average gain dbi Horizontal Pattern: Half-power beam width Front-to-back ratio, copolar db > 27 > 27 > 27 Cross polar ratio Maindirection 0 Sector ±60 db Tracking, Avg. db 1.0 Squint ±2.5 Vertical Pattern: Half-power beam width Electrical tilt 0 8, continuously adjustable Sidelobe suppression for first sidelobe above main beam avg. T db Impedance Ω 50 VSWR < 1.5 Isolation, between ports db > 30 Intermodulation IM3 dbc < 150 (2 x 43 dbm carrier) Max. power per input W 400 (at 50 C ambient temperature) Mechanical specifications /a Subject to alteration. Input Connector position Adjustment mechanism 4 x 7-16 female Rearside 2x, Position bottom continuously adjustable Wind load (at Rated N lbf Frontal: Wind Speed: 150 km/h) Maximal: Max. wind velocity km/h mph Height/width/depth mm inches Category of mounting hardware Weight kg lb Packing size mm inches Scope of supply / 576 / / 22.7 / 3.9 H (Heavy) 24 / 26 (clamps incl.) 52.9 / 57.3 (clamps incl.) 2500 x 600 x x 23.6 x 5.9 Panel and 2 units of clamps for mm inches diameter V01 Page 1 of 2

2 Accessories General Information Accessories (order separately if required) Type No. Description Remarks mm inches Weight approx. kg lb Units per antenna clamp Mast diameter: clamp Mast diameter: downtilt kit Downtilt angle: Accessories (included in the scope of supply) clamp Mast diameter: Material: Grounding: Reflector screen: Weather-proof aluminum. Fiberglass radome: The grey fiberglass radomes of these antennas are very stable and extraordinarily stiff. They are resistant to ultraviolet radiation and can also be painted to match their surroundings. All screws and nuts: Stainless steel. The metal parts of the antenna including the mounting kit and the inner conductors are DC grounded. Detail see below Correlation Table Frequency range Array Connector MHz R1 1 2 MHz R2 3 4 R1 R2 Layout of interface: Detail /a Subject to alteration. Page 2 of V01

3 Mounting Hardware Clamp Included in the Scope of Supply Suitable for mast diameter Antenna mast distance Material of clamp and screws Weight (mm) [inches] (mm) [inches] (kg) [lb] [ ] [ ] Hot-dip galvanized steel / stainless steel 1.1 [2.43] 152 [5.98] 100 [3.94] 72 [2.83] [ ] 40 [1.57] 35 [1.38] 64 [2.52] 125 [4.92] /c Subject to alteration. 40 [1.57] [ ] M10 M A = 25 Nm M8 M A = 20 Nm [ ] Please note: Kathrein does not recommend to use counter nuts. The additional nuts supplied are only meant as spares. All dimensions in mm and [inches] Page 1 of 1

4 General Instructions for Adjustment Mechanism Description of the adjustment mechanism (protective cap removed): ➀ Twist protection. ➁ Downtilt spindle with integrated scale. ➀ Thread for fixing the pro tective cap or the RCU (Remote Control Unit). ➁ Gearwheel for RCU power drive. To set the downtilt angle exactly, you must look horizontally at the scale. The lower edge of the gearwheel must be used for alignment. Manual adjustment procedure: 0 max. 0 max. Remove the protective cap and the twist protection completely. Set downtilt angle by rotating the gearwheel. Screw on the twist protection and the protective cap again. Optional: RCU (Remote Control Unit) for remote-controlled downtilt adjustment: /a Subject to alteration. For a description of RCU installation please refer to the respective data sheet. Page 1 of 2

5 General Instructions for Feederline and RCU Installation for Antennas Please note: In order not to damage the interfaces, please make sure that only the right tools are used. Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench width. Description of bottom end cap (exemplary picture): Adjustment mechanism (protective cap removed) Ventilation hole Spindle with tilting scale 7-16 female (long neck) Colour coding: Correlation of each RF input to: the corresponding adjustment mechanism the frequency range the polarization Installation of the feederline connector and RCU (optional): In order to protect the adjustment mechanism, the protective caps have to be attached during feederline installation! Kathrein installation set: Type No Set has to be ordered separately! Set consists of three spanners of divers width 27, 32 and 41 mm 1.1, 1.3 and 1.6 inches 1/2 square actuation according to DIN 3120 Form C Carefully place the connector and fix the nut using a torque-wrench (according to the manufacturers guidelines). After feederline installation, the optional remote control units (RCUs) can be mounted All dimensions in mm inches These tools are suitable for 7-16 connectors with a wrench size of 27 or 32 mm 1.1 or 1.3 inches, and the RCU attachment nut with a wrench size of 41 mm 1.6 inches /a Subject to alteration. Tighten nuts within a torque range of Nm depending on connector manufacturers specifications, respectively the RCU nut with a torque range of Nm. Page 2 of 2

2-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT

2-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT Frequency Range Dual Polarization HPBW Adjust. Electr. DT 1695 2690 2 10 set by hand or by optional RCU (Remote Control Unit) Y1 X 35 2-Port Antenna 1695 2690 35 19.5dBi 2 10 T Type No. 80010678 Highband

More information

Maximizer & Optimizer Fixed Tilt Antennas Polarization: Vertical Electrical Downtilt: Fixed or Variable Horizontal beamwidth: 65, 80 or 90

Maximizer & Optimizer Fixed Tilt Antennas Polarization: Vertical Electrical Downtilt: Fixed or Variable Horizontal beamwidth: 65, 80 or 90 : Electrical Downtilt: Fixed or Variable Horizontal beamwidth: 65, 8 or 9 Applications This well-known ranges of fixed or variable tilt antennas are vertically polarized for space diversity with an option

More information

Directional Antenna MHz K SITEL Caponago Tel.02 /

Directional Antenna MHz K SITEL Caponago Tel.02 / 47 86 MHz K 72 6 4. SITEL Caponago Tel.2 / 95.74.6.9 ly polarized broadband directional antenna made of aluminum and protected by a fiberglass cover. Type No. K 72 6 47 K 72 6 41 A Input 7-16 female N

More information

A-PDF Merger DEMO : Purchase from to remove the watermark

A-PDF Merger DEMO : Purchase from  to remove the watermark A-PDF Merger DEMO : Purchase from www.a-pdf.com to remove the watermark Model: ZDADJ1800-16-120 VPol 1710 «1880MHz 120 16dBi Sector Panel Antenna Electrical DataFrequency Range-MHz1710 «1880 Gain-dBi16

More information

HexPort Multi-Band Antenna

HexPort Multi-Band Antenna DATA SHEET Four foot (1.2 m), six port antenna with a 65 azimuth beamwidth covering 698-894 MHz and 1710-2360 MHz Four high band and two low band ports including the WCS band in a single antenna Sharp

More information

OctoPort Multi-Band Antenna

OctoPort Multi-Band Antenna DATA SHEET Six foot (1.8 m), eight port antenna with an 45 azimuth beamwidth covering 698-787 MHz, 824-896 MHz and 1695-2180 MHz Four high band and four low band ports in a single antenna Sharp elevation

More information

Multi-band Bi-SectorTM Array

Multi-band Bi-SectorTM Array DATA SHEET Patented twin asymmetric beam 33 Bi-Sector array phase array over a frequency range of (698-896 MHz) and (1710-2360 MHz), optimized to match existing cloverleaf (65 ) deployments. 4 low band

More information

BRS Quasi-Omni Antenna

BRS Quasi-Omni Antenna DATA SHEET Sub two foot (0.5 m), two port, quasi-omni antenna with uniform horizontal beamwidths covering the BRS band from 2496-2690 MHz 360 of coverage area across all bands of operation in a single

More information

GHz Standard Performance Dual Pole Parabolic Reflector Antenna

GHz Standard Performance Dual Pole Parabolic Reflector Antenna 5.25-5.85 GHz Standard Performance Dual Pole Parabolic Reflector Antenna Standard Performance Dual Pole Parabolic Reflector Antennas from Cambium Networks are well suited for deployment with any of the

More information

PRODUCT NAME ORDER # PAGE # ANTENNAS

PRODUCT NAME ORDER # PAGE # ANTENNAS PRODUCT NAME ORDER # PAGE # ANTENNAS 890-960 Yagi Antenna UBR-Y9000 w/ lead 0580 450 Mhz Yagi Antenna UBR-Y4000 w/ lead 05803 806-960 & 70-990 MHz Dual Band Omni Antenna 09835 3 806-960 & 70-500 Yagi Multiband

More information

Enterprise-class MIMO Sector Antenna

Enterprise-class MIMO Sector Antenna Datasheet Enterprise-class MIMO Sector Antenna Enterprise-class MIMO Sector Antenna A Cost-effective PtMP Deployment Solution with Durable Design and Flexible Installation. EnGenius introduces the new

More information

INSTRUCTION MANUAL_. Specifications. Electrical.

INSTRUCTION MANUAL_. Specifications. Electrical. 308 Industrial Park Road Starkville, MS 39759 USA Ph: (662) 323-9538 FAX: (662) 323-6551 DX-77A 7-Band HF Vertical 10, 12, 15, 17, 20, 30, 40-Meter INSTRUCTION MANUAL_ General Description The "DX-77-A"

More information

High Power Directional Coupler

High Power Directional Coupler DATA SHEET High power coupler at 500 W across a wideband from 698 to 2700 MHz Low RF Insertion Loss and excellent return loss performance Outdoor unit with a wide range of coupling values from 6 to 20

More information

PRELIMINARY COMPEX SYSTEMS

PRELIMINARY COMPEX SYSTEMS MIMO Junior Series Dual Band 2x2 MIMO /b/g/n Long Range Outdoor Access Point 2x2 at 300Mbps / 2x2 at 867Mbps (Wave-2) Specifications Chipset System Memory NOR Flash Antenna Interface Reset Button LED Power

More information

Please follow the procedure marked with this symbol precisely. Non-compliance may lead to damage of the product.

Please follow the procedure marked with this symbol precisely. Non-compliance may lead to damage of the product. Revision L, October 2016 Mounting Kits for Single Band 160mm (6.3 ) Profile Panel Antennas F-074-S4, T-075-S4 & T-095-S4 General This instruction sheet contains all necessary information required to assist

More information

2.88 OD Universal Mast Mount

2.88 OD Universal Mast Mount Revision A January 19, 2006 ASSEMBLY MANUAL 2.88 OD Universal Mast Mount GENERAL DYNAMICS PRODELIN CORPORATION 1500 Prodelin Drive Newton NC 28658USA Phone 828-464-4141 www.gdsatcom.com 2.88 O.D. Universal

More information

THE ANTENNA SUPPORT MANUAL ANTENNA SUPPORT

THE ANTENNA SUPPORT MANUAL ANTENNA SUPPORT PRODUCT NR: 1763 DRAWING NR: CD 2770 THE is designed for installation of any kind of panel antennas, radio links up to Ø1,2 meters with strut support or other common telecom equipment. It can be installed

More information

SPECIFICATION. Part No. : GW

SPECIFICATION. Part No. : GW SPECIFICATION Part No. : GW.71.13 Product Name : 2.4GHz/.8GHz Dipole Antenna for ISM Band and WLAN IEEE 82.11a/b/g/h Feature : dbi High Performance Antenna RP-SMA(M) Hinged Antenna RoHS Compliant SPE-11-8-12/C

More information

Following symbols can be found next to text outlining important information.

Following symbols can be found next to text outlining important information. Revision J, October 2016 641 mm Profile Panel Antennas General This instruction manual contains all necessary information required to assist in the correct installation of Panel Antennas of 641 mm (25.2

More information

1291BL Series Technical Specification Single Axis Position and Rate Table System

1291BL Series Technical Specification Single Axis Position and Rate Table System Datasheet 1291BL Series Technical Specification Single Axis Position and Rate Table System DESCRIPTION The Model 1291BL Single Axis Position and Rate Table System is designed to provide precise position,

More information

ASSEMBLY AND INSTALLATION INSTRUCTIONS 738XB 70 CM OSCAR BOOMER MHz COMMUNICATIONS ANTENNAS (7/94)

ASSEMBLY AND INSTALLATION INSTRUCTIONS 738XB 70 CM OSCAR BOOMER MHz COMMUNICATIONS ANTENNAS (7/94) ASSEMBLY AND INSTALLATION INSTRUCTIONS 7XB 70 CM OSCAR BOOMER 432-4 MHz COMMUNICATIONS ANTENNAS 951451 (7/94) WARNING THIS ANTENNA IS AN ELECTRICAL CONDUCTOR. CONTACT WITH POWER LINES CAN RESULT IN DEATH,

More information

High RF (HiRF) EMC Solutions Overview

High RF (HiRF) EMC Solutions Overview EMC Solutions HiRF s High RF (HiRF) EMC Solutions Overview Q par Angus Ltd have teamed up with TMD Technologies Ltd to produce a range of unrivalled antenna and amplifier solutions that exceed the latest

More information

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS ACTUATOR LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS PRODUCT HANDBOOK APPLICATION The LKS 160 air damper actuator is designed to be fitted to multi-stage or modulating oil and gas burners

More information

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in ventilation and air conditioning

More information

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System Datasheet 1291BL Series Technical Specification Single-Axis Rate and Positioning Table System DESCRIPTION The Model 1291BL Single Axis Positioning and Rate Table System is designed to provide precise position,

More information

Installation Instructions 6 ft Antennas Adv. Backring (with T-Mount) PA, PAL, PAD, SP, PAX, PADX, SPX DA, UA, SU, SD, SDF, DAX, UDA, UXA, SDX, SUX

Installation Instructions 6 ft Antennas Adv. Backring (with T-Mount) PA, PAL, PAD, SP, PAX, PADX, SPX DA, UA, SU, SD, SDF, DAX, UDA, UXA, SDX, SUX Installation Instructions 6 ft Antennas Adv. Backring (with T-Mount) PA, PAL, PAD, SP, PAX, PADX, SPX DA, UA, SU, SD, SDF, DAX, UDA, UXA, SDX, SUX NMT 628-00(e) DA, UA, SU, SD, SDF DAX, UDA, UXA, SDX,

More information

Terminating RFS LCF /8 Corrugated Coaxial Cable with RFS Omni-Fit (F) N-Connector

Terminating RFS LCF /8 Corrugated Coaxial Cable with RFS Omni-Fit (F) N-Connector December 12, 2018 RFS TRIM-L-158-A Trimming and Stripping Tool Additional Tools Used for Termination Drill press vice temporarily attached to trailer tailgate to secure cable during termination. Obviously,

More information

Mounting Bracket for Antenna EXTENT D5501i

Mounting Bracket for Antenna EXTENT D5501i Model Number: 62-28-09 TM Mounting, / Wall Installation for EXTENT D5501i Mounting for EXTENT D5501i / Wall Mount DESCRIPTION: Galtronics mounting bracket offers an easy installation solution to mount

More information

LKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS

LKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS ACTUATOR LKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS PRODUCT HANDBOOK APPLICATION The LKS 170 air damper actuator is designed to be fitted to multi-stage or modulating oil and

More information

DIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 6 SPECIFICATION COMMERCIALLY AVAILABLE. CERAMIC FILTER PART NUMBER: CF RoHS

DIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 6 SPECIFICATION COMMERCIALLY AVAILABLE. CERAMIC FILTER PART NUMBER: CF RoHS DIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 6 SPECIFICATION COMMERCIALLY AVAILABLE CERAMIC FILTER PART NUMBER: CF-13501505 RoHS ISSUED CHECKED CHECKED CHECKED APPROVED 12/14/09 kn 10/25/12 DS 11/15/12

More information

outdoor access point Multi Point Station Series

outdoor access point Multi Point Station Series Multi Point Station Series Dual Band 2x2 MIMO 802.11ac/b/g/n Long Range Outdoor Access Point 560MHz CPU / 300Mbps / 867Mbps Model: MPS344 KEY FEATURES Qualcomm Atheros 560MHz Processor AR9344 IEEE 802.11ac/a/b/g/n

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Running times: - SQM1... 14...100

More information

SPECIFICATION COMMERCIALLY AVAILABLE. CERAMIC FILTER PART NUMBER: CF RoHS ISSUED / REVISION ENGINEER APPROVED DOCUMENT CHECKED DRAFTSMAN

SPECIFICATION COMMERCIALLY AVAILABLE. CERAMIC FILTER PART NUMBER: CF RoHS ISSUED / REVISION ENGINEER APPROVED DOCUMENT CHECKED DRAFTSMAN DIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 6 SPECIFICATION COMMERCIALLY AVAILABLE CERAMIC FILTER PART NUMBER: CF-22505105 RoHS ISSUED / REVISION ENGINEER APPROVED DOCUMENT CHECKED DRAFTSMAN 7/6/07**

More information

Multi Point Station Series

Multi Point Station Series Multi Point Station Series Dual Band 2x2 MIMO 802.11ac/b/g/n Long Range Outdoor Access Point 560MHz CPU / 300Mbps / 867Mbps Model: MPS344 KEY FEATURES Qualcomm Atheros 560MHz Processor AR9344 IEEE 802.11ac/a/b/g/n

More information

These Installation Instructions are valid for antennas in the following version :

These Installation Instructions are valid for antennas in the following version : Installation Instructions 8 ft Antennas PA, PAL, PAD, PAX, PADX DA, UA, DAX, UDA, UXA HTT 81.221-15 (e) These installation instructions have been written for qualified, skilled personnel. The antenna shall

More information

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL FEB 25, 2004 CERAMIC DIPLEX FILTER SPECIFICATION 1 OF 6 SPECIFICATION FOR APPROVAL ITEM: CERAMIC DIPLEX FILTER PART NUMBER: CFD-122715756 ISSUED CHECKED CHECKED CHECKED APPROVED FILTRONETICS Inc FEB 25,

More information

These Installation Instructions are valid for antennas in the following version :

These Installation Instructions are valid for antennas in the following version : Installation Instructions 8 ft Antennas PA, PAL, PAD, PAX, PADX DA, UA, DAX, UDA, UXA HTT 81.221-12(e) These installation instructions have been written for qualified, skilled personnel. The antenna shall

More information

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of spring return actuator Description Spring-return actuator for adjusting and regulating dampers and valves in air conditioning and ventilation. Torque

More information

TC26-B Vehicle Sensor

TC26-B Vehicle Sensor Section 1 General Description The Model TC26-B is a microprocessor controlled vehicle sensor with a variable range. It is designed to trigger the operation of a traffic controller. The TC26-B will only

More information

LMR-195-LLPX. LMR -195-LLPX Flexible Low Loss Plenum Coax TIMES MICROWAVE SYSTEMS

LMR-195-LLPX. LMR -195-LLPX Flexible Low Loss Plenum Coax TIMES MICROWAVE SYSTEMS LMR-195-LLPX LMR -195-LLPX Flexible Low Loss Plenum Coax Ideal for Indoor/Outdoor Plenum Feeder runs Drop in replacement for RG-142 UL/NEC/CSA rated CMP/FT6 (listed under UL file #E-170516) Any wireless

More information

SPECIFICATION COMMERCIALLY AVAILABLE CERAMIC BAND PASS FILTER PART NUMBER: CF RoHS ISSUED CHECKED CHECKED CHECKED APPROVED.

SPECIFICATION COMMERCIALLY AVAILABLE CERAMIC BAND PASS FILTER PART NUMBER: CF RoHS ISSUED CHECKED CHECKED CHECKED APPROVED. Page 1 of 6 SPECIFICATION COMMERCIALLY AVAILABLE CERAMIC BAND PASS FILTER PART NUMBER: CF-22500024 RoHS 12/7/09 Added Attenuation and graph 9/1/17 Added Recommended Solder Pattern ISSUED CHECKED CHECKED

More information

New-Tronics Ltd. Beyond Your Expectations. CB, SCANNER ANTENNAS and Accessories CATALOG

New-Tronics Ltd. Beyond Your Expectations. CB, SCANNER ANTENNAS and Accessories CATALOG New-Tronics Ltd. Beyond Your Expectations CB, SCANNER ANTENNAS and Accessories CATALOG TOLL FREE ORDER LINE: (877) 994-9499 (940) 325-1386 FAX (940) 328-1409 www.new-tronics.com email: sales@new-tronics.com

More information

Connected Home OTRX 2-way 1.2GHz Regal Tap

Connected Home OTRX 2-way 1.2GHz Regal Tap 5-1218MHz Hum and noise tested to ANSI/SCTE 16 2001 RF and power bypass capability Compatible with existing Regal Taps Available in faceplate only replacements Overview The Technetix OTRX series of Regal

More information

SPECIFICATION COMMERCIALLY AVAILABLE CERAMIC FILTER PART NUMBER: CF DOCUMENT CHECKED 9/28/11 DS 12/01/2011 TFG 12/01/2011 GL

SPECIFICATION COMMERCIALLY AVAILABLE CERAMIC FILTER PART NUMBER: CF DOCUMENT CHECKED 9/28/11 DS 12/01/2011 TFG 12/01/2011 GL DIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 6 SPECIFICATION COMMERCIALLY AVAILABLE CERAMIC FILTER PART NUMBER: CF-32002005 ISSUED / REVISION ENGINEER APPROVED DOCUMENT CHECKED DRAFTSMAN DOCUMENT CHECKED

More information

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners 7 812 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Running times: - SQM1... 14...100

More information

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications. Metal-Enclosed Limit Switches ENM2 Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications. Product advantages Standard switch

More information

These Installation Instructions are valid for antennas in the following version :

These Installation Instructions are valid for antennas in the following version : Installation Instructions 10 ft Antennas PA, PAL, PAD, PAX, PADX DA, UA, DAX, UDA, UXA HTT 81.222-11(e) These installation instructions have been written for qualified, skilled personnel. The antenna shall

More information

Isolatoren / Stand-off Insulators ST 300 / ST 500. Specification. Parts List. These stand-off insulators are made for indoor use.

Isolatoren / Stand-off Insulators ST 300 / ST 500. Specification. Parts List. These stand-off insulators are made for indoor use. Isolatoren / Stand-off Insulators ST 300 / ST 500 These stand-off insulators are made for indoor use. They are made of plastic material. The flange has three slotted holes permitting to align the insulator

More information

Broad multiplex outlet BF-V...

Broad multiplex outlet BF-V... Air distribution systems Broad multiplex outlet BF-V... DS 40 E 04.0 Technical Selection Preliminary remarks In many applications in the commercial sector, supply air is discharged via simple grilles built

More information

INPAQ Global RF/Component Solutions

INPAQ Global RF/Component Solutions HCM 1012 G Series Specification Product Name Series Chip Filter HCM G Series Low Profile Type Size EIAJ 1012 HCM1012G SERIES LOW PROFILE TYPE (Chip Filter) Engineering Specification Features and Application.Powerful

More information

Mid to High Power FM Antennas

Mid to High Power FM Antennas Mid to High Power FM Antennas FMM Series FMP Series Micronetixx builds two mid to high power FM antenna families, the FMM, and the FMP. Both series of antennas are constructed from rugged stainless steel

More information

CROSS FIELD ARRAY-2 (CFA-2) Long Throw/High Intelligibility All-Weather Loudspeaker System V100/2015

CROSS FIELD ARRAY-2 (CFA-2) Long Throw/High Intelligibility All-Weather Loudspeaker System V100/2015 CROSS FIELD ARRAY-2 (CFA-2) Long Throw/High Intelligibility All-Weather Loudspeaker System V100/2015 The One Systems Cross Field Array-2 (CFA-2) was designed to provide very high intelligibility and acoustic

More information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information with the World s Smallest Mounting Area Subminiature model as small as.2 (H). (W) (L) mm is ideal for high-density mounting ((U)-2F(-Y)). Low profile of.2 mm improves mounting efficiency ((U)-2F(-Y)).

More information

CAT-1 Series 3. Installation Guide. The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877

CAT-1 Series 3. Installation Guide. The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877 CAT-1 Series 3 Installation Guide The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877 (203) 431-0262 (203) 431-0296 FAX tvg@cat-1.com Installation of Load Cells for CAT-1 Systems

More information

SPECIFICATION COMMERCIALLY AVAILABLE ITEM: DIELECTRIC CERAMIC FILTER PART NUMBER CF ROHS

SPECIFICATION COMMERCIALLY AVAILABLE ITEM: DIELECTRIC CERAMIC FILTER PART NUMBER CF ROHS DIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 6 SPECIFICATION COMMERCIALLY AVAILABLE ITEM: DIELECTRIC CERAMIC FILTER PART NUMBER CF-14871365 ROHS ISSUED / REVISION ENGINEER APPROVED DOCUMENT CHECKED DRAFTSMAN

More information

TYRE PRESSURE MONITORING SYSTEMS 2017 EDITION

TYRE PRESSURE MONITORING SYSTEMS 2017 EDITION TYRE PRESSURE MONITORING SYSTEMS 2017 EDITION Backed by over ten years of experience in TPMS tyre pressure monitoring systems, REMA TIP TOP has built a diagnostics and TPMS product portfolio that goes

More information

Traffic Logix SafePace 450 Radar Speed Sign

Traffic Logix SafePace 450 Radar Speed Sign Traffic Logix SafePace 450 Radar Speed Sign Product Specifications Dimensions Digit: 15.0 (h) x 8.0 (w), 112 LEDs per digit Text: o Full Size: Letters 6.0 (h) spell YOUR SPEED fixed message, 2 lines o

More information

FISCHER FREEDOM TM SERIES

FISCHER FREEDOM TM SERIES K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68

More information

Reli-a-Flex TM Reliance

Reli-a-Flex TM Reliance Reli-a-Flex TM Reliance Precision Mechatronics LLP www.myostat.ca Reli-a-Flex - Accurate transfer of motion between two shafts Patented: - UK No. 2316735 - US No. 6,203,437 B1 - European No. EP 0922168

More information

20 HUBER+SUHNER RADOX SOLAR

20 HUBER+SUHNER RADOX SOLAR All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX

More information

EGE is a group of companies assembled in an internationally operating holding company, offers primarily deliveries of special equipment for the power

EGE is a group of companies assembled in an internationally operating holding company, offers primarily deliveries of special equipment for the power EGE is a group of companies assembled in an internationally operating holding company, offers primarily deliveries of special equipment for the power engineering industry busducts, arc suppression coils

More information

2520- EC Motor Speed Controller

2520- EC Motor Speed Controller 2520- EC Motor Speed Controller T1 AC Line Voltage From Contactor T2 or Neutral 760-ECM ECM Motor BLACK ORANGE BLACK RED (+) Signal 24VAC (-) GND Features Motor Types: ECM (dc brushless) Motors Motor Speed:

More information

Publication No.: PSG

Publication No.: PSG TABLE OF CONTENTS PAGE 1.0 SCOPE...2 2.0 STANDARDS...2 3.0 DESIGN REQUIREMENTS...2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Resistors... 3 3.04 Interrupter... 4 3.05 SF 6 Gas System... 4 3.06

More information

MITSET. System Overview

MITSET. System Overview MITSET System Overview Climber Specs The scoring equation for last year s s competition was m payload * V avg / m structural The climber had to be able to ascend a 50m ribbon at an average speed of 1m/s.

More information

Hi-Z Antennas 4-8 PRO UP Level2 8 Element Circle Array Manual Converts the Hi-Z 4 to the Hi-Z 4-8PRO

Hi-Z Antennas 4-8 PRO UP Level2 8 Element Circle Array Manual Converts the Hi-Z 4 to the Hi-Z 4-8PRO 1 HIGH PERFORMANCE HF RECEIVING SYSTEMS & COMPONENTS Hi-Z Antennas 4-8 PRO UP Level2 8 Element Circle Array Manual Converts the Hi-Z 4 to the Hi-Z 4-8PRO Hi-Z 4-8PRO Shack Switch Hi-Z 4-8PRO PnP Interface

More information

Conductions, Lightning protections

Conductions, Lightning protections Conductions, Lightning Conductions; Lightning 7 Conductions; Lightning Round wire Wires for lightning protection and earthing systems Round wire different materials available in various dimensions Specification

More information

SPG-400. Solar-powered generators

SPG-400. Solar-powered generators SPG-400 Solar-powered generators Features & Benefits: - The GS-SPG series features four 100 Watt solar panels installed on a single support with adjustable tilt angle. - The 480 Amp hour battery assembly,

More information

Tender No. : Ref. No. : LSGS-13-CX User / Customer : Page No. : 1 of 9. Specification. For

Tender No. : Ref. No. : LSGS-13-CX User / Customer : Page No. : 1 of 9. Specification. For Tender No. : Ref. No. : LSGS-13-CX0022-05 User / Customer : Page No. : 1 of 9 Tender Title : Bidder : LS Cable & System Ltd. Document Title : Specification For RG Cable

More information

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive Technical data sheet NFU Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations Torque: 10Nm Nominal voltage: AC 4... 40V DC 4...15V

More information

INDUSTRY APPLICATIONS

INDUSTRY APPLICATIONS TLF Compact INDUSTRY APPLICATIONS STEMMANN-TECHNIK QUALITY MADE IN GERMANY TLF Compact Compact spring-driven cable reels The cable reel serie TLF Compact covers a large spectrum of applications and requirements.

More information

User Guide. BreezePro TPW-400DT 12/24V 400W Wind Turbine A. NOTICE. B. SAFETY PRECAUTIONS (Important) C. About BreezePro

User Guide. BreezePro TPW-400DT 12/24V 400W Wind Turbine A. NOTICE. B. SAFETY PRECAUTIONS (Important) C. About BreezePro A. NOTICE User Guide BreezePro TPW-400DT 12/24V 400W Wind Turbine 1. This information is believed to be reliable; however, We assume no responsibility for inaccuracies or omissions. The user of this information

More information

SPECIAL SPECIFICATION 8676 Solar Panel Power Supply System

SPECIAL SPECIFICATION 8676 Solar Panel Power Supply System 2004 Specifications CSJ 2552-01-033 SPECIAL SPECIFICATION 8676 Solar Panel Power Supply System 1. Description. This work shall consist of furnishing and installing an integrated Solar Panel Power Supply

More information

Axle Load Scale XTR686

Axle Load Scale XTR686 VER 001 Axle Load Scale XTR686 Operating Manual - 1 - INDEX 1. INTRODUCTION... 3 Installation Precautions 2. MAIN FEATURES... 4 3. TECHNICAL SPECIFICATIONS... 5 Dimension Product specifications 4. HOW

More information

COUPLING MAINLINE LOSS * (db) (db) Max. L M U U 1 L M U U 1 L. Max.

COUPLING MAINLINE LOSS * (db) (db) Max. L M U U 1 L M U U 1 L. Max. Surface Mount top hat Directional Coupler 75Ω, 20dB coupling, 5 to 1250 MHz Maximum Ratings Operating Temperature -40 C to 85 C Features very flat coupling Storage Temperature -55 C to 100 C very broadband,

More information

THEFT PROOF CABLE STORAGE REEL, OPTIONAL ELECTRIC, MULTIPLE REELS, SPLIT REELS AND HANDLES

THEFT PROOF CABLE STORAGE REEL, OPTIONAL ELECTRIC, MULTIPLE REELS, SPLIT REELS AND HANDLES LMS 85 HW 85 MODEL, 5 EA-21 MULTIPLE SECTIONS Lifetime Warranty, 36 X 21 SUPER HEAVY-DUTY BASE SECTION, ALL SECTIONS ASTM A500-07, A53-12, GRADE B, CARBON STEEL, SCHEDULE 40 STRUCTURAL TUBING Lifetime

More information

Aerials Dishes Mast amplifiers Mast combiners Single channel filters Notch filters Stacking combiners Passives Mounting accessories

Aerials Dishes Mast amplifiers Mast combiners Single channel filters Notch filters Stacking combiners Passives Mounting accessories Product info Aerials Dishes Mast amplifiers Mast combiners Single channel filters Notch filters Stacking combiners Passives Mounting accessories High quality range of SCS splitters and SCT taps for your

More information

MD2U Series 2-Phase Unipolar Stepper Motor Driver

MD2U Series 2-Phase Unipolar Stepper Motor Driver MDU Series -Phase Unipolar Stepper Motor Driver Compact nd High-Performance Of -Phase Stepper Motor Driver Features Unipolar constant current drive type Enable to brake when it stops by STOP current adjustment

More information

RP SMA Male Connector Crimp/Solder Attachment for RG174, RG316, RG188, PE-B100, PE-C100, inch, LMR-100

RP SMA Male Connector Crimp/Solder Attachment for RG174, RG316, RG188, PE-B100, PE-C100, inch, LMR-100 RP SMA Male Connector Crimp/Solder Attachment for RG174, RG316, RG188, PE-B100, PE-C100, 0100 inch, LMR-100 RF Connectors Technical Data Sheet PE4771 Configuration SMA Male Reverse Polarity Connector MIL-STD-348

More information

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68

More information

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater KROHNE 12/2006 7.02343.22.00 MAR UFM 800 W, C and UFM 800 W Hot Tapping Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...with built-on or built-in sensors for

More information

SMC SERIES Subminiature Coaxial Connectors

SMC SERIES Subminiature Coaxial Connectors SERIES Subminiature Coaxial Connectors FEATURES Subminiature coaxial connectors with 50 Ω impedance for applications up to 0 GHz. (screw on mechanism)fulfills the subminiature coaxial connector requirement

More information

Instruction Manual For The WildBlue 65cm x 75cm Elliptical Ka Antenna

Instruction Manual For The WildBlue 65cm x 75cm Elliptical Ka Antenna Raven 2009ODU Manual Instruction Manual For The WildBlue 65cm x 75cm Elliptical Ka Antenna 1035-09-004-A Caution This instruction leaflet will assist you in the correct installation of the product. Read

More information

Rocket Locker. Installation Guide. October 2012

Rocket Locker. Installation Guide. October 2012 Rocket Locker Installation Guide October 2012 Notices The contents of this document and the associated software are the property of Utility, Inc. Any reproduction in whole or in part is strictly prohibited.

More information

Table of Contents SMA CONNECTORS

Table of Contents SMA CONNECTORS Table of Contents 45 SMA Connectors 3 MMCX Connectors 50 Ohm Connectors Specifications...46 Quick Connect...49 Semi-Rigid & Flexible Cable...50 PC Mount...56 Bulkhead & Panel Mount...62 Self-Fixture End

More information

Wide band isolators (Peripheral Mode) 1-3 // // 2-6 // // 2-18 // //4-12// 4-20// 6-21// 8-18

Wide band isolators (Peripheral Mode) 1-3 // // 2-6 // // 2-18 // //4-12// 4-20// 6-21// 8-18 SMA/N/ K Connector options (X) Isolator Port 1 Port 2 Female Male -1 Male Female -2 Female Female -3 Male Male -4 Tolerance Table Metric (inch) (unless otherwise stated): Hole diameter +/- 0.1mm, (+/-

More information

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv) Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv) Order code MF-04-510-HN-442 Series and function (plug pins on top, see pictures) 441 = 12 V DC without plug socket 442 =

More information

Model Number Structure

Model Number Structure Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved

More information

MBS 1200 and MBS 1250

MBS 1200 and MBS 1250 Data sheet OEM Pressure Transmitters for heavy-duty applications MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic applications. The programme

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

BAIRD Wall Mounting System WL-2(23")

BAIRD Wall Mounting System WL-2(23) BAIRD Wall Mounting System WL-2(23") The WL-2(23") Wall Mounting System is engineered to handle up to and including a 10' (3.0M) antenna. The WL-2(23") has a 23" offset from the wall to the mast. The customer

More information

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor

More information

NOVALYNX CORPORATION MODEL 200-WS-02F WIND SPEED & DIRECTION SENSOR INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL 200-WS-02F WIND SPEED & DIRECTION SENSOR INSTRUCTION MANUAL NOVALYNX CORPORATION MODEL 200-WS-02F WIND SPEED & DIRECTION SENSOR INSTRUCTION MANUAL REVISION DATE: MAY 2005 Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify

More information

FireFox. FireFox The new one. FireFox The reliable one. FireFox The versatile one. FireFox The simple one. FireFox The fast one

FireFox. FireFox The new one. FireFox The reliable one. FireFox The versatile one. FireFox The simple one. FireFox The fast one FireFox Most blind rivet nut setting devices are lift-controlled, the others are setting force-controlled The FireFox from GESIPA represents a new generation of blind rivet nut setting device which allows

More information

Features. 15 s 20 s 30 s. Heat Humidity Cold Vibration Material Housing Cover Colour Weight

Features. 15 s 20 s 30 s. Heat Humidity Cold Vibration Material Housing Cover Colour Weight 800 schneider-electric.com 2 Product Description 800 is an electro-mechanical actuator for the control of twoway and three-way globe/plug valves in: domestic hot water systems heating systems air handling

More information

20 l/min (5 GPM) p max. Technical Features

20 l/min (5 GPM) p max. Technical Features Proportional Directional Control Valve, with Analogue Control Electronics PRM2-0 Functional Description Size 0 (D02) Q max 20 l/min (5 GPM) p max 320 bar (600 PSI) Technical Features Direct acting, proportional

More information

SERIES BMA, SUBMINIATURE BLIND MATE CONNECTORS

SERIES BMA, SUBMINIATURE BLIND MATE CONNECTORS SERIES, SUBMINIATURE BLIND MATE CONNECTORS DESCRIPTION CONTENTS PAGE HUBER+SUHNER blind mate connectors open up special dimensions in microwave applications up to 18 GHz. HUBER+SUHNER offers a range of

More information

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250 Data sheet OEM Pressure Transmitters for heavy-duty applications Type MBS 100 and MBS 150 The compact OEM pressure transmitter programme is designed for use in severe hydraulic applications. The programme

More information

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com NEAR FIELD PROBE SET BROADBAND RESPONSE

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com NEAR FIELD PROBE SET BROADBAND RESPONSE Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com INSTRUCTION MANUAL NEAR FIELD PROBE SET BROADBAND RESPONSE MODEL EM-6992 gff ELEC:TRO METRIC:S INSTRUCTION

More information

M700. Forta SPECIFICATIONS. Spring return actuator for valves

M700. Forta SPECIFICATIONS. Spring return actuator for valves 01 Spring return actuator for valves is a spring return electro-mechanical actuator for the control of two-way and three-way plug valves in: domestic hot water systems heating systems air handling systems

More information

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend:

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend: General technical data: 1.) Anodised aluminium housing with a connecting rod made of aluminium (in the case of motor types G..B, G..C, G..D and G..E, the connecting rod is Ø18, for all other motor types

More information