V
|
|
- Bonnie Moody
- 5 years ago
- Views:
Transcription
1 4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT R set by hand or by optional RCU (Remote Control Unit) X 65 R2 X 65 4-Port Antenna / 65 / /17.5dBi 0 8 /0 8 T Type No V01 Lowbands R1; R2 Frequency range MHz Polarization +45, , , 45 Average gain dbi Horizontal Pattern: Half-power beam width Front-to-back ratio, copolar db > 27 > 27 > 27 Cross polar ratio Maindirection 0 Sector ±60 db Tracking, Avg. db 1.0 Squint ±2.5 Vertical Pattern: Half-power beam width Electrical tilt 0 8, continuously adjustable Sidelobe suppression for first sidelobe above main beam avg. T db Impedance Ω 50 VSWR < 1.5 Isolation, between ports db > 30 Intermodulation IM3 dbc < 150 (2 x 43 dbm carrier) Max. power per input W 400 (at 50 C ambient temperature) Mechanical specifications /a Subject to alteration. Input Connector position Adjustment mechanism 4 x 7-16 female Rearside 2x, Position bottom continuously adjustable Wind load (at Rated N lbf Frontal: Wind Speed: 150 km/h) Maximal: Max. wind velocity km/h mph Height/width/depth mm inches Category of mounting hardware Weight kg lb Packing size mm inches Scope of supply / 576 / / 22.7 / 3.9 H (Heavy) 24 / 26 (clamps incl.) 52.9 / 57.3 (clamps incl.) 2500 x 600 x x 23.6 x 5.9 Panel and 2 units of clamps for mm inches diameter V01 Page 1 of 2
2 Accessories General Information Accessories (order separately if required) Type No. Description Remarks mm inches Weight approx. kg lb Units per antenna clamp Mast diameter: clamp Mast diameter: downtilt kit Downtilt angle: Accessories (included in the scope of supply) clamp Mast diameter: Material: Grounding: Reflector screen: Weather-proof aluminum. Fiberglass radome: The grey fiberglass radomes of these antennas are very stable and extraordinarily stiff. They are resistant to ultraviolet radiation and can also be painted to match their surroundings. All screws and nuts: Stainless steel. The metal parts of the antenna including the mounting kit and the inner conductors are DC grounded. Detail see below Correlation Table Frequency range Array Connector MHz R1 1 2 MHz R2 3 4 R1 R2 Layout of interface: Detail /a Subject to alteration. Page 2 of V01
3 Mounting Hardware Clamp Included in the Scope of Supply Suitable for mast diameter Antenna mast distance Material of clamp and screws Weight (mm) [inches] (mm) [inches] (kg) [lb] [ ] [ ] Hot-dip galvanized steel / stainless steel 1.1 [2.43] 152 [5.98] 100 [3.94] 72 [2.83] [ ] 40 [1.57] 35 [1.38] 64 [2.52] 125 [4.92] /c Subject to alteration. 40 [1.57] [ ] M10 M A = 25 Nm M8 M A = 20 Nm [ ] Please note: Kathrein does not recommend to use counter nuts. The additional nuts supplied are only meant as spares. All dimensions in mm and [inches] Page 1 of 1
4 General Instructions for Adjustment Mechanism Description of the adjustment mechanism (protective cap removed): ➀ Twist protection. ➁ Downtilt spindle with integrated scale. ➀ Thread for fixing the pro tective cap or the RCU (Remote Control Unit). ➁ Gearwheel for RCU power drive. To set the downtilt angle exactly, you must look horizontally at the scale. The lower edge of the gearwheel must be used for alignment. Manual adjustment procedure: 0 max. 0 max. Remove the protective cap and the twist protection completely. Set downtilt angle by rotating the gearwheel. Screw on the twist protection and the protective cap again. Optional: RCU (Remote Control Unit) for remote-controlled downtilt adjustment: /a Subject to alteration. For a description of RCU installation please refer to the respective data sheet. Page 1 of 2
5 General Instructions for Feederline and RCU Installation for Antennas Please note: In order not to damage the interfaces, please make sure that only the right tools are used. Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench width. Description of bottom end cap (exemplary picture): Adjustment mechanism (protective cap removed) Ventilation hole Spindle with tilting scale 7-16 female (long neck) Colour coding: Correlation of each RF input to: the corresponding adjustment mechanism the frequency range the polarization Installation of the feederline connector and RCU (optional): In order to protect the adjustment mechanism, the protective caps have to be attached during feederline installation! Kathrein installation set: Type No Set has to be ordered separately! Set consists of three spanners of divers width 27, 32 and 41 mm 1.1, 1.3 and 1.6 inches 1/2 square actuation according to DIN 3120 Form C Carefully place the connector and fix the nut using a torque-wrench (according to the manufacturers guidelines). After feederline installation, the optional remote control units (RCUs) can be mounted All dimensions in mm inches These tools are suitable for 7-16 connectors with a wrench size of 27 or 32 mm 1.1 or 1.3 inches, and the RCU attachment nut with a wrench size of 41 mm 1.6 inches /a Subject to alteration. Tighten nuts within a torque range of Nm depending on connector manufacturers specifications, respectively the RCU nut with a torque range of Nm. Page 2 of 2
2-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT
Frequency Range Dual Polarization HPBW Adjust. Electr. DT 1695 2690 2 10 set by hand or by optional RCU (Remote Control Unit) Y1 X 35 2-Port Antenna 1695 2690 35 19.5dBi 2 10 T Type No. 80010678 Highband
More informationMaximizer & Optimizer Fixed Tilt Antennas Polarization: Vertical Electrical Downtilt: Fixed or Variable Horizontal beamwidth: 65, 80 or 90
: Electrical Downtilt: Fixed or Variable Horizontal beamwidth: 65, 8 or 9 Applications This well-known ranges of fixed or variable tilt antennas are vertically polarized for space diversity with an option
More informationDirectional Antenna MHz K SITEL Caponago Tel.02 /
47 86 MHz K 72 6 4. SITEL Caponago Tel.2 / 95.74.6.9 ly polarized broadband directional antenna made of aluminum and protected by a fiberglass cover. Type No. K 72 6 47 K 72 6 41 A Input 7-16 female N
More informationA-PDF Merger DEMO : Purchase from to remove the watermark
A-PDF Merger DEMO : Purchase from www.a-pdf.com to remove the watermark Model: ZDADJ1800-16-120 VPol 1710 «1880MHz 120 16dBi Sector Panel Antenna Electrical DataFrequency Range-MHz1710 «1880 Gain-dBi16
More informationHexPort Multi-Band Antenna
DATA SHEET Four foot (1.2 m), six port antenna with a 65 azimuth beamwidth covering 698-894 MHz and 1710-2360 MHz Four high band and two low band ports including the WCS band in a single antenna Sharp
More informationOctoPort Multi-Band Antenna
DATA SHEET Six foot (1.8 m), eight port antenna with an 45 azimuth beamwidth covering 698-787 MHz, 824-896 MHz and 1695-2180 MHz Four high band and four low band ports in a single antenna Sharp elevation
More informationMulti-band Bi-SectorTM Array
DATA SHEET Patented twin asymmetric beam 33 Bi-Sector array phase array over a frequency range of (698-896 MHz) and (1710-2360 MHz), optimized to match existing cloverleaf (65 ) deployments. 4 low band
More informationBRS Quasi-Omni Antenna
DATA SHEET Sub two foot (0.5 m), two port, quasi-omni antenna with uniform horizontal beamwidths covering the BRS band from 2496-2690 MHz 360 of coverage area across all bands of operation in a single
More informationGHz Standard Performance Dual Pole Parabolic Reflector Antenna
5.25-5.85 GHz Standard Performance Dual Pole Parabolic Reflector Antenna Standard Performance Dual Pole Parabolic Reflector Antennas from Cambium Networks are well suited for deployment with any of the
More informationPRODUCT NAME ORDER # PAGE # ANTENNAS
PRODUCT NAME ORDER # PAGE # ANTENNAS 890-960 Yagi Antenna UBR-Y9000 w/ lead 0580 450 Mhz Yagi Antenna UBR-Y4000 w/ lead 05803 806-960 & 70-990 MHz Dual Band Omni Antenna 09835 3 806-960 & 70-500 Yagi Multiband
More informationEnterprise-class MIMO Sector Antenna
Datasheet Enterprise-class MIMO Sector Antenna Enterprise-class MIMO Sector Antenna A Cost-effective PtMP Deployment Solution with Durable Design and Flexible Installation. EnGenius introduces the new
More informationINSTRUCTION MANUAL_. Specifications. Electrical.
308 Industrial Park Road Starkville, MS 39759 USA Ph: (662) 323-9538 FAX: (662) 323-6551 DX-77A 7-Band HF Vertical 10, 12, 15, 17, 20, 30, 40-Meter INSTRUCTION MANUAL_ General Description The "DX-77-A"
More informationHigh Power Directional Coupler
DATA SHEET High power coupler at 500 W across a wideband from 698 to 2700 MHz Low RF Insertion Loss and excellent return loss performance Outdoor unit with a wide range of coupling values from 6 to 20
More informationPRELIMINARY COMPEX SYSTEMS
MIMO Junior Series Dual Band 2x2 MIMO /b/g/n Long Range Outdoor Access Point 2x2 at 300Mbps / 2x2 at 867Mbps (Wave-2) Specifications Chipset System Memory NOR Flash Antenna Interface Reset Button LED Power
More informationPlease follow the procedure marked with this symbol precisely. Non-compliance may lead to damage of the product.
Revision L, October 2016 Mounting Kits for Single Band 160mm (6.3 ) Profile Panel Antennas F-074-S4, T-075-S4 & T-095-S4 General This instruction sheet contains all necessary information required to assist
More information2.88 OD Universal Mast Mount
Revision A January 19, 2006 ASSEMBLY MANUAL 2.88 OD Universal Mast Mount GENERAL DYNAMICS PRODELIN CORPORATION 1500 Prodelin Drive Newton NC 28658USA Phone 828-464-4141 www.gdsatcom.com 2.88 O.D. Universal
More informationTHE ANTENNA SUPPORT MANUAL ANTENNA SUPPORT
PRODUCT NR: 1763 DRAWING NR: CD 2770 THE is designed for installation of any kind of panel antennas, radio links up to Ø1,2 meters with strut support or other common telecom equipment. It can be installed
More informationSPECIFICATION. Part No. : GW
SPECIFICATION Part No. : GW.71.13 Product Name : 2.4GHz/.8GHz Dipole Antenna for ISM Band and WLAN IEEE 82.11a/b/g/h Feature : dbi High Performance Antenna RP-SMA(M) Hinged Antenna RoHS Compliant SPE-11-8-12/C
More informationFollowing symbols can be found next to text outlining important information.
Revision J, October 2016 641 mm Profile Panel Antennas General This instruction manual contains all necessary information required to assist in the correct installation of Panel Antennas of 641 mm (25.2
More information1291BL Series Technical Specification Single Axis Position and Rate Table System
Datasheet 1291BL Series Technical Specification Single Axis Position and Rate Table System DESCRIPTION The Model 1291BL Single Axis Position and Rate Table System is designed to provide precise position,
More informationASSEMBLY AND INSTALLATION INSTRUCTIONS 738XB 70 CM OSCAR BOOMER MHz COMMUNICATIONS ANTENNAS (7/94)
ASSEMBLY AND INSTALLATION INSTRUCTIONS 7XB 70 CM OSCAR BOOMER 432-4 MHz COMMUNICATIONS ANTENNAS 951451 (7/94) WARNING THIS ANTENNA IS AN ELECTRICAL CONDUCTOR. CONTACT WITH POWER LINES CAN RESULT IN DEATH,
More informationHigh RF (HiRF) EMC Solutions Overview
EMC Solutions HiRF s High RF (HiRF) EMC Solutions Overview Q par Angus Ltd have teamed up with TMD Technologies Ltd to produce a range of unrivalled antenna and amplifier solutions that exceed the latest
More informationLKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS
ACTUATOR LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS PRODUCT HANDBOOK APPLICATION The LKS 160 air damper actuator is designed to be fitted to multi-stage or modulating oil and gas burners
More informationPower consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point
Actuators Technical data sheet Continuous control of rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in ventilation and air conditioning
More information1291BL Series Technical Specification Single-Axis Rate and Positioning Table System
Datasheet 1291BL Series Technical Specification Single-Axis Rate and Positioning Table System DESCRIPTION The Model 1291BL Single Axis Positioning and Rate Table System is designed to provide precise position,
More informationInstallation Instructions 6 ft Antennas Adv. Backring (with T-Mount) PA, PAL, PAD, SP, PAX, PADX, SPX DA, UA, SU, SD, SDF, DAX, UDA, UXA, SDX, SUX
Installation Instructions 6 ft Antennas Adv. Backring (with T-Mount) PA, PAL, PAD, SP, PAX, PADX, SPX DA, UA, SU, SD, SDF, DAX, UDA, UXA, SDX, SUX NMT 628-00(e) DA, UA, SU, SD, SDF DAX, UDA, UXA, SDX,
More informationTerminating RFS LCF /8 Corrugated Coaxial Cable with RFS Omni-Fit (F) N-Connector
December 12, 2018 RFS TRIM-L-158-A Trimming and Stripping Tool Additional Tools Used for Termination Drill press vice temporarily attached to trailer tailgate to secure cable during termination. Obviously,
More informationMounting Bracket for Antenna EXTENT D5501i
Model Number: 62-28-09 TM Mounting, / Wall Installation for EXTENT D5501i Mounting for EXTENT D5501i / Wall Mount DESCRIPTION: Galtronics mounting bracket offers an easy installation solution to mount
More informationLKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS
ACTUATOR LKS 170 FOR AIR DAMPERS ON SINGLE, DUAL STAGE AND MODULATING BURNERS PRODUCT HANDBOOK APPLICATION The LKS 170 air damper actuator is designed to be fitted to multi-stage or modulating oil and
More informationDIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 6 SPECIFICATION COMMERCIALLY AVAILABLE. CERAMIC FILTER PART NUMBER: CF RoHS
DIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 6 SPECIFICATION COMMERCIALLY AVAILABLE CERAMIC FILTER PART NUMBER: CF-13501505 RoHS ISSUED CHECKED CHECKED CHECKED APPROVED 12/14/09 kn 10/25/12 DS 11/15/12
More informationoutdoor access point Multi Point Station Series
Multi Point Station Series Dual Band 2x2 MIMO 802.11ac/b/g/n Long Range Outdoor Access Point 560MHz CPU / 300Mbps / 867Mbps Model: MPS344 KEY FEATURES Qualcomm Atheros 560MHz Processor AR9344 IEEE 802.11ac/a/b/g/n
More informationActuators for air dampers and control valves of oil burners
7 812 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Running times: - SQM1... 14...100
More informationSPECIFICATION COMMERCIALLY AVAILABLE. CERAMIC FILTER PART NUMBER: CF RoHS ISSUED / REVISION ENGINEER APPROVED DOCUMENT CHECKED DRAFTSMAN
DIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 6 SPECIFICATION COMMERCIALLY AVAILABLE CERAMIC FILTER PART NUMBER: CF-22505105 RoHS ISSUED / REVISION ENGINEER APPROVED DOCUMENT CHECKED DRAFTSMAN 7/6/07**
More informationMulti Point Station Series
Multi Point Station Series Dual Band 2x2 MIMO 802.11ac/b/g/n Long Range Outdoor Access Point 560MHz CPU / 300Mbps / 867Mbps Model: MPS344 KEY FEATURES Qualcomm Atheros 560MHz Processor AR9344 IEEE 802.11ac/a/b/g/n
More informationThese Installation Instructions are valid for antennas in the following version :
Installation Instructions 8 ft Antennas PA, PAL, PAD, PAX, PADX DA, UA, DAX, UDA, UXA HTT 81.221-15 (e) These installation instructions have been written for qualified, skilled personnel. The antenna shall
More informationSPECIFICATION FOR APPROVAL
FEB 25, 2004 CERAMIC DIPLEX FILTER SPECIFICATION 1 OF 6 SPECIFICATION FOR APPROVAL ITEM: CERAMIC DIPLEX FILTER PART NUMBER: CFD-122715756 ISSUED CHECKED CHECKED CHECKED APPROVED FILTRONETICS Inc FEB 25,
More informationThese Installation Instructions are valid for antennas in the following version :
Installation Instructions 8 ft Antennas PA, PAL, PAD, PAX, PADX DA, UA, DAX, UDA, UXA HTT 81.221-12(e) These installation instructions have been written for qualified, skilled personnel. The antenna shall
More informationPower consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point
Actuators Technical data sheet Continuous control of spring return actuator Description Spring-return actuator for adjusting and regulating dampers and valves in air conditioning and ventilation. Torque
More informationTC26-B Vehicle Sensor
Section 1 General Description The Model TC26-B is a microprocessor controlled vehicle sensor with a variable range. It is designed to trigger the operation of a traffic controller. The TC26-B will only
More informationLMR-195-LLPX. LMR -195-LLPX Flexible Low Loss Plenum Coax TIMES MICROWAVE SYSTEMS
LMR-195-LLPX LMR -195-LLPX Flexible Low Loss Plenum Coax Ideal for Indoor/Outdoor Plenum Feeder runs Drop in replacement for RG-142 UL/NEC/CSA rated CMP/FT6 (listed under UL file #E-170516) Any wireless
More informationSPECIFICATION COMMERCIALLY AVAILABLE CERAMIC BAND PASS FILTER PART NUMBER: CF RoHS ISSUED CHECKED CHECKED CHECKED APPROVED.
Page 1 of 6 SPECIFICATION COMMERCIALLY AVAILABLE CERAMIC BAND PASS FILTER PART NUMBER: CF-22500024 RoHS 12/7/09 Added Attenuation and graph 9/1/17 Added Recommended Solder Pattern ISSUED CHECKED CHECKED
More informationNew-Tronics Ltd. Beyond Your Expectations. CB, SCANNER ANTENNAS and Accessories CATALOG
New-Tronics Ltd. Beyond Your Expectations CB, SCANNER ANTENNAS and Accessories CATALOG TOLL FREE ORDER LINE: (877) 994-9499 (940) 325-1386 FAX (940) 328-1409 www.new-tronics.com email: sales@new-tronics.com
More informationConnected Home OTRX 2-way 1.2GHz Regal Tap
5-1218MHz Hum and noise tested to ANSI/SCTE 16 2001 RF and power bypass capability Compatible with existing Regal Taps Available in faceplate only replacements Overview The Technetix OTRX series of Regal
More informationSPECIFICATION COMMERCIALLY AVAILABLE CERAMIC FILTER PART NUMBER: CF DOCUMENT CHECKED 9/28/11 DS 12/01/2011 TFG 12/01/2011 GL
DIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 6 SPECIFICATION COMMERCIALLY AVAILABLE CERAMIC FILTER PART NUMBER: CF-32002005 ISSUED / REVISION ENGINEER APPROVED DOCUMENT CHECKED DRAFTSMAN DOCUMENT CHECKED
More informationActuators for air dampers and control valves of oil burners
7 812 Actuators for air dampers and control valves of oil burners SQM1... SQM2... Reversible electromotoric actuators Torques: - SQM1... up to 10 Nm - SQM2... up to 20 Nm Running times: - SQM1... 14...100
More informationRecommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.
Metal-Enclosed Limit Switches ENM2 Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications. Product advantages Standard switch
More informationThese Installation Instructions are valid for antennas in the following version :
Installation Instructions 10 ft Antennas PA, PAL, PAD, PAX, PADX DA, UA, DAX, UDA, UXA HTT 81.222-11(e) These installation instructions have been written for qualified, skilled personnel. The antenna shall
More informationIsolatoren / Stand-off Insulators ST 300 / ST 500. Specification. Parts List. These stand-off insulators are made for indoor use.
Isolatoren / Stand-off Insulators ST 300 / ST 500 These stand-off insulators are made for indoor use. They are made of plastic material. The flange has three slotted holes permitting to align the insulator
More informationBroad multiplex outlet BF-V...
Air distribution systems Broad multiplex outlet BF-V... DS 40 E 04.0 Technical Selection Preliminary remarks In many applications in the commercial sector, supply air is discharged via simple grilles built
More informationINPAQ Global RF/Component Solutions
HCM 1012 G Series Specification Product Name Series Chip Filter HCM G Series Low Profile Type Size EIAJ 1012 HCM1012G SERIES LOW PROFILE TYPE (Chip Filter) Engineering Specification Features and Application.Powerful
More informationMid to High Power FM Antennas
Mid to High Power FM Antennas FMM Series FMP Series Micronetixx builds two mid to high power FM antenna families, the FMM, and the FMP. Both series of antennas are constructed from rugged stainless steel
More informationCROSS FIELD ARRAY-2 (CFA-2) Long Throw/High Intelligibility All-Weather Loudspeaker System V100/2015
CROSS FIELD ARRAY-2 (CFA-2) Long Throw/High Intelligibility All-Weather Loudspeaker System V100/2015 The One Systems Cross Field Array-2 (CFA-2) was designed to provide very high intelligibility and acoustic
More informationG6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information
with the World s Smallest Mounting Area Subminiature model as small as.2 (H). (W) (L) mm is ideal for high-density mounting ((U)-2F(-Y)). Low profile of.2 mm improves mounting efficiency ((U)-2F(-Y)).
More informationCAT-1 Series 3. Installation Guide. The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877
CAT-1 Series 3 Installation Guide The Valley Group, Inc. 871 Ethan Allen Hwy. Suite 104 Ridgefield, CT 06877 (203) 431-0262 (203) 431-0296 FAX tvg@cat-1.com Installation of Load Cells for CAT-1 Systems
More informationSPECIFICATION COMMERCIALLY AVAILABLE ITEM: DIELECTRIC CERAMIC FILTER PART NUMBER CF ROHS
DIELECTRIC CERAMIC FILTER SPECIFICATION 1 OF 6 SPECIFICATION COMMERCIALLY AVAILABLE ITEM: DIELECTRIC CERAMIC FILTER PART NUMBER CF-14871365 ROHS ISSUED / REVISION ENGINEER APPROVED DOCUMENT CHECKED DRAFTSMAN
More informationTYRE PRESSURE MONITORING SYSTEMS 2017 EDITION
TYRE PRESSURE MONITORING SYSTEMS 2017 EDITION Backed by over ten years of experience in TPMS tyre pressure monitoring systems, REMA TIP TOP has built a diagnostics and TPMS product portfolio that goes
More informationTraffic Logix SafePace 450 Radar Speed Sign
Traffic Logix SafePace 450 Radar Speed Sign Product Specifications Dimensions Digit: 15.0 (h) x 8.0 (w), 112 LEDs per digit Text: o Full Size: Letters 6.0 (h) spell YOUR SPEED fixed message, 2 lines o
More informationFISCHER FREEDOM TM SERIES
K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68
More informationReli-a-Flex TM Reliance
Reli-a-Flex TM Reliance Precision Mechatronics LLP www.myostat.ca Reli-a-Flex - Accurate transfer of motion between two shafts Patented: - UK No. 2316735 - US No. 6,203,437 B1 - European No. EP 0922168
More information20 HUBER+SUHNER RADOX SOLAR
All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX
More informationEGE is a group of companies assembled in an internationally operating holding company, offers primarily deliveries of special equipment for the power
EGE is a group of companies assembled in an internationally operating holding company, offers primarily deliveries of special equipment for the power engineering industry busducts, arc suppression coils
More information2520- EC Motor Speed Controller
2520- EC Motor Speed Controller T1 AC Line Voltage From Contactor T2 or Neutral 760-ECM ECM Motor BLACK ORANGE BLACK RED (+) Signal 24VAC (-) GND Features Motor Types: ECM (dc brushless) Motors Motor Speed:
More informationPublication No.: PSG
TABLE OF CONTENTS PAGE 1.0 SCOPE...2 2.0 STANDARDS...2 3.0 DESIGN REQUIREMENTS...2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Resistors... 3 3.04 Interrupter... 4 3.05 SF 6 Gas System... 4 3.06
More informationMITSET. System Overview
MITSET System Overview Climber Specs The scoring equation for last year s s competition was m payload * V avg / m structural The climber had to be able to ascend a 50m ribbon at an average speed of 1m/s.
More informationHi-Z Antennas 4-8 PRO UP Level2 8 Element Circle Array Manual Converts the Hi-Z 4 to the Hi-Z 4-8PRO
1 HIGH PERFORMANCE HF RECEIVING SYSTEMS & COMPONENTS Hi-Z Antennas 4-8 PRO UP Level2 8 Element Circle Array Manual Converts the Hi-Z 4 to the Hi-Z 4-8PRO Hi-Z 4-8PRO Shack Switch Hi-Z 4-8PRO PnP Interface
More informationConductions, Lightning protections
Conductions, Lightning Conductions; Lightning 7 Conductions; Lightning Round wire Wires for lightning protection and earthing systems Round wire different materials available in various dimensions Specification
More informationSPG-400. Solar-powered generators
SPG-400 Solar-powered generators Features & Benefits: - The GS-SPG series features four 100 Watt solar panels installed on a single support with adjustable tilt angle. - The 480 Amp hour battery assembly,
More informationTender No. : Ref. No. : LSGS-13-CX User / Customer : Page No. : 1 of 9. Specification. For
Tender No. : Ref. No. : LSGS-13-CX0022-05 User / Customer : Page No. : 1 of 9 Tender Title : Bidder : LS Cable & System Ltd. Document Title : Specification For RG Cable
More informationPower consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive
Technical data sheet NFU Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations Torque: 10Nm Nominal voltage: AC 4... 40V DC 4...15V
More informationINDUSTRY APPLICATIONS
TLF Compact INDUSTRY APPLICATIONS STEMMANN-TECHNIK QUALITY MADE IN GERMANY TLF Compact Compact spring-driven cable reels The cable reel serie TLF Compact covers a large spectrum of applications and requirements.
More informationUser Guide. BreezePro TPW-400DT 12/24V 400W Wind Turbine A. NOTICE. B. SAFETY PRECAUTIONS (Important) C. About BreezePro
A. NOTICE User Guide BreezePro TPW-400DT 12/24V 400W Wind Turbine 1. This information is believed to be reliable; however, We assume no responsibility for inaccuracies or omissions. The user of this information
More informationSPECIAL SPECIFICATION 8676 Solar Panel Power Supply System
2004 Specifications CSJ 2552-01-033 SPECIAL SPECIFICATION 8676 Solar Panel Power Supply System 1. Description. This work shall consist of furnishing and installing an integrated Solar Panel Power Supply
More informationAxle Load Scale XTR686
VER 001 Axle Load Scale XTR686 Operating Manual - 1 - INDEX 1. INTRODUCTION... 3 Installation Precautions 2. MAIN FEATURES... 4 3. TECHNICAL SPECIFICATIONS... 5 Dimension Product specifications 4. HOW
More informationCOUPLING MAINLINE LOSS * (db) (db) Max. L M U U 1 L M U U 1 L. Max.
Surface Mount top hat Directional Coupler 75Ω, 20dB coupling, 5 to 1250 MHz Maximum Ratings Operating Temperature -40 C to 85 C Features very flat coupling Storage Temperature -55 C to 100 C very broadband,
More informationTHEFT PROOF CABLE STORAGE REEL, OPTIONAL ELECTRIC, MULTIPLE REELS, SPLIT REELS AND HANDLES
LMS 85 HW 85 MODEL, 5 EA-21 MULTIPLE SECTIONS Lifetime Warranty, 36 X 21 SUPER HEAVY-DUTY BASE SECTION, ALL SECTIONS ASTM A500-07, A53-12, GRADE B, CARBON STEEL, SCHEDULE 40 STRUCTURAL TUBING Lifetime
More informationAerials Dishes Mast amplifiers Mast combiners Single channel filters Notch filters Stacking combiners Passives Mounting accessories
Product info Aerials Dishes Mast amplifiers Mast combiners Single channel filters Notch filters Stacking combiners Passives Mounting accessories High quality range of SCS splitters and SCT taps for your
More informationMD2U Series 2-Phase Unipolar Stepper Motor Driver
MDU Series -Phase Unipolar Stepper Motor Driver Compact nd High-Performance Of -Phase Stepper Motor Driver Features Unipolar constant current drive type Enable to brake when it stops by STOP current adjustment
More informationRP SMA Male Connector Crimp/Solder Attachment for RG174, RG316, RG188, PE-B100, PE-C100, inch, LMR-100
RP SMA Male Connector Crimp/Solder Attachment for RG174, RG316, RG188, PE-B100, PE-C100, 0100 inch, LMR-100 RF Connectors Technical Data Sheet PE4771 Configuration SMA Male Reverse Polarity Connector MIL-STD-348
More informationK CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES
K CHAPTER FISCHER TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION KEY FEATURES No key code: 360 mating freedom & optimized cable management Membrane-sealed contacts (patent pending) Low profile IP68
More informationUFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater
KROHNE 12/2006 7.02343.22.00 MAR UFM 800 W, C and UFM 800 W Hot Tapping Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...with built-on or built-in sensors for
More informationSMC SERIES Subminiature Coaxial Connectors
SERIES Subminiature Coaxial Connectors FEATURES Subminiature coaxial connectors with 50 Ω impedance for applications up to 0 GHz. (screw on mechanism)fulfills the subminiature coaxial connector requirement
More informationInstruction Manual For The WildBlue 65cm x 75cm Elliptical Ka Antenna
Raven 2009ODU Manual Instruction Manual For The WildBlue 65cm x 75cm Elliptical Ka Antenna 1035-09-004-A Caution This instruction leaflet will assist you in the correct installation of the product. Read
More informationRocket Locker. Installation Guide. October 2012
Rocket Locker Installation Guide October 2012 Notices The contents of this document and the associated software are the property of Utility, Inc. Any reproduction in whole or in part is strictly prohibited.
More informationTable of Contents SMA CONNECTORS
Table of Contents 45 SMA Connectors 3 MMCX Connectors 50 Ohm Connectors Specifications...46 Quick Connect...49 Semi-Rigid & Flexible Cable...50 PC Mount...56 Bulkhead & Panel Mount...62 Self-Fixture End
More informationWide band isolators (Peripheral Mode) 1-3 // // 2-6 // // 2-18 // //4-12// 4-20// 6-21// 8-18
SMA/N/ K Connector options (X) Isolator Port 1 Port 2 Female Male -1 Male Female -2 Female Female -3 Male Male -4 Tolerance Table Metric (inch) (unless otherwise stated): Hole diameter +/- 0.1mm, (+/-
More informationElectrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)
Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv) Order code MF-04-510-HN-442 Series and function (plug pins on top, see pictures) 441 = 12 V DC without plug socket 442 =
More informationModel Number Structure
Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved
More informationMBS 1200 and MBS 1250
Data sheet OEM Pressure Transmitters for heavy-duty applications MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic applications. The programme
More informationvertical fuse switch disconnectors
SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -
More informationBAIRD Wall Mounting System WL-2(23")
BAIRD Wall Mounting System WL-2(23") The WL-2(23") Wall Mounting System is engineered to handle up to and including a 10' (3.0M) antenna. The WL-2(23") has a 23" offset from the wall to the mast. The customer
More informationPower consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point
Actuators Technical data sheet Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor
More informationNOVALYNX CORPORATION MODEL 200-WS-02F WIND SPEED & DIRECTION SENSOR INSTRUCTION MANUAL
NOVALYNX CORPORATION MODEL 200-WS-02F WIND SPEED & DIRECTION SENSOR INSTRUCTION MANUAL REVISION DATE: MAY 2005 Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify
More informationFireFox. FireFox The new one. FireFox The reliable one. FireFox The versatile one. FireFox The simple one. FireFox The fast one
FireFox Most blind rivet nut setting devices are lift-controlled, the others are setting force-controlled The FireFox from GESIPA represents a new generation of blind rivet nut setting device which allows
More informationFeatures. 15 s 20 s 30 s. Heat Humidity Cold Vibration Material Housing Cover Colour Weight
800 schneider-electric.com 2 Product Description 800 is an electro-mechanical actuator for the control of twoway and three-way globe/plug valves in: domestic hot water systems heating systems air handling
More information20 l/min (5 GPM) p max. Technical Features
Proportional Directional Control Valve, with Analogue Control Electronics PRM2-0 Functional Description Size 0 (D02) Q max 20 l/min (5 GPM) p max 320 bar (600 PSI) Technical Features Direct acting, proportional
More informationSERIES BMA, SUBMINIATURE BLIND MATE CONNECTORS
SERIES, SUBMINIATURE BLIND MATE CONNECTORS DESCRIPTION CONTENTS PAGE HUBER+SUHNER blind mate connectors open up special dimensions in microwave applications up to 18 GHz. HUBER+SUHNER offers a range of
More informationOEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250
Data sheet OEM Pressure Transmitters for heavy-duty applications Type MBS 100 and MBS 150 The compact OEM pressure transmitter programme is designed for use in severe hydraulic applications. The programme
More informationTest Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com NEAR FIELD PROBE SET BROADBAND RESPONSE
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com INSTRUCTION MANUAL NEAR FIELD PROBE SET BROADBAND RESPONSE MODEL EM-6992 gff ELEC:TRO METRIC:S INSTRUCTION
More informationM700. Forta SPECIFICATIONS. Spring return actuator for valves
01 Spring return actuator for valves is a spring return electro-mechanical actuator for the control of two-way and three-way plug valves in: domestic hot water systems heating systems air handling systems
More informationOrdering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend:
General technical data: 1.) Anodised aluminium housing with a connecting rod made of aluminium (in the case of motor types G..B, G..C, G..D and G..E, the connecting rod is Ø18, for all other motor types
More information