From the dawn of Excellence emanates the high noon of Performance.
|
|
- Sandra Hubbard
- 5 years ago
- Views:
Transcription
1 From the dawn of Excellence emanates the high noon of Performance.
2 Gelco Electronics is a full service electronic company that manufactures superior quality electronic control & measuring equipment alongwith power saving devices. Established in 1984, the company is located in the industrial belt of Ahmedabad, which is one of the fastest developing metropolitan cities of India. Our state of the art manufacturing facility with its prolific R&D centre in conjunction with our strict adherence to quality control and safety norms has ensured an impressive growth record in these past three decades. More importantly, it has gained a reputation of Excel- lence & Dependability from its clients. After achieving wide success in the Indian market, Gelco Electronics is now spreading its wings internationally. To attain the same level of success globally, Gelco Electronics has conducted extensive research in each market to understand their electrical equipment s needs and subsequently, developed specific products for them that are longlasting, efficient and safe. R a n g e of P r o d u c t s Single Phase Motor Starters & Control Panel Three Phase DOL Motor Starters & Control Panel Three Phase Star Delta Motor Starters & Control Panel Duty Stand by Panel for Duplex Pumps Panel Accessories A p p l i c at i o n s Home Agriculture Industries
3 SINGLE PHASE MOTOR STARTER Input Supply voltage : 230V, AC ±20% Output supply voltage : 230V, AC +20% INDEX Topic Page Single Phase Motor Starter 1-2 Single Phase Electronic Control Panel 3 Three Phase Dol Motor Starter 4-5 Three Phase Dol Motor Starter - Metal Body 6 Three Phase Star Delta Motor Starter 7 Three Phase Dol Electronic Control Panel 8 Three Phase Star Delta Electronic Control Panel 9 Duty Stand By Panel For Duplex Pumps Operation 10 Stabilizer 11 Auto Switch 12 Motor Starter 13 A.C. Switch 14 Phase Failure Relay 15 Phase Failure Relay 16 Motor Protection Relay 17 Pump Protection Relay 18 Analog Timer Digital Timer 21 Digital Time Switch 22 Earth Leakage Relay Earth Leakage Circuit Breaker 25 Panel Meters 26 Automatic Light Controller 27 Spp With Water Level Guard 28 Water Level Controller (1.1) GSS-MCB Easy to operate Overload protection through MCB Economical Solution Enclosure made from Engineering grade Plastic (ABS) Only for Oil Filled Pump set Motor H.P. Run Capacitor MCB 0.75 HP MFD 10 Amp. 1.0 HP MFD 10 Amp. 1.5 HP MFD 16 Amp. 2.0 HP MFD 25 Amp. (1.2) GSS-RE Electronic Start/Stop push buttons. Electronic Overload protection High voltage protection above 270 Vac. Low voltage protection below 150 Vac. Engineering grade plastic enclosure (ABS). Facility to connect Gelco Water Level Controller Adaptor NOTE: A wide range of products which can be offered on request. We can supply starter / panel / A.T.S. panel / 60 Hz starter / panel as per customer s specifications. A wide range of lighting products which can be offered on request. We can supply submersible flat & round, PVC & rubber, 3 core and 4 core cable. We can supply submersible pumpsets, monoblock pumpsets, industrial pumpset, electric induction motors & UPVC column pipes etc. Due to continues R & D; specifications, construction of materials, design, out look, colour & finishing etc. can be changed without intimation. ( LLC-001D/LLC-001) Only for Oil Filled Pump set Motor H.P. Run Capacitor MCB 0.75 HP MFD 4-10 Amp. 1.0 HP MFD 4-10 Amp. 1.5 HP MFD Amp. 2.0 HP MFD Amp. 1
4 SINGLE PHASE MOTOR STARTER Input Supply voltage : 230V, AC ±20% Output supply voltage : 230V, AC +20% SINGLE PHASE ELECTRONIC CONTROL PANEL Input Supply voltage : 230V, AC ±20% Output supply voltage : 230V, AC ±20% (1.3) DCP - RE Electronic Start/Stop Push button. In built digital volt and amp meter Latest Micro Controller Based Technology for better accuracy Presice protection against Overload( Over Current) Presice protection aganist high voltage Presice protection against low voltage Dry run protection ( Optional) Digital indication of fault condition. Engineering grade plastic enclosure( ABS) Facility to connect GELCO Water Level Controller Adaptor ( LLC-001D) Parameters can be programmable Only for Oil filled pumpset Motor H.P. Run Capacitor 1.0 HP 36 MFD 1.5 HP 50 MFD 2.0 HP 72 MFD (2.1) MCB WS In built digital Volt and Amp. Meter ( GELCO ACCURA) Easy to operate Powder coated sheet metal enclosure. Submersible/Monoblock Pump set. MCB Start Capacitor Run Capacitor /120 MFD 36 MFD /200 MFD MFD /250 MFD MFD /250 MFD MFD (2.2) DCP Fully automatic Electronic Start/Stop facility Digital Micro Controller based technology Higher accuracy Digital indication of fault condition. Precise overload protection( Over Current) Precise Overvoltage protection Precise Under voltage protection Dry run Protection. Parameters can be programmable In built Auto ON/OFF timer ( Minutes) Powder Coated sheet metal enclosure. Submersible/Monoblock Pumpset for water in residence, commercial, farming, gardening. Motor H.P. Start Capacitor Run Capacitor 1.0 HP 100/120 MFD 36 MFD 1.5 HP 150/200 MFD MFD 2.0 HP 200/250 MFD MFD 2 3
5 THREE PHASE DOL MOTOR STARTER Input/Output Voltage :415 V ± 20%VAC (3.1) GTW Current sensing unit Inverse current characteristics Electronic start/stop push button facility Electronic overload protection. Under voltage protection Dry run protection(optional). Reverse phasing protection Can be used up to 7.5Hp DOL moter/pumps Other Models are also available on request D.O.L. Submersible Pump set for water in residence, commercial, farming, gardening. Induction motor in industries Type GTW-304 GTW-305 GTW-306 (3.2) GTV Current Range 2-5 Amp Amp Amp. All facilities available as per GTW Current and voltage sensing unit Facility to connect GELCO Water Level Controller (Model LLC-001/LLC-001D) Can be used up to 7.5Hp DOL moter/pumps D.O.L. Submersible Pump set for water in residence, commercial, farming, gardening. Induction motor in industries Type GTV-304 GTV-305 GTV-306 Current Range 2-5 Amp Amp Amp. (3.3) GTA Current Sensing Unit Additional facility to make Motor/Pump ON automatically after power supply resumption. One minute Time Delay before start Can be used up to 7.5Hp DOL moter/pumps D.O.L. Submersible Pump set for water in residence, commercial, farming, gardening. Induction motor in industries Type GTA-304 GTA-305 GTA-306 (3.4) DCP Current Range 2-5 Amp Amp Amp. Used latest Micro controller based technolgy Electronic Start/Stop push button Inbuilt digital volt & amp Meter Digital display of fault condition Electronic overload protection Under voltage protection Dry Run protection Parameters can be programmed Reverse phasing protection Facility to connect GELCO Water Level Controller Adaptor ( LLC-001D) Can be used up to 7.5Hp DOL moter/pumps Three phase DOL Submersible/Monoblock Pump set for water in residence, commercial, farming, gardening Current Range 2-5 Amp. 4 5
6 THREE PHASE DOL MOTOR STARTER - METAL BODY Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC THREE PHASE STAR DELTA MOTOR STARTER Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC (4.1) GEW-1(DOL) (5.1) GLO-FASD / SA-Metal Body Easy to operate Powder Coated sheet metal enclosure. Thermal Overload protection D.O.L Motors for water in residence, commercial, farming, gardening. Motor H.P. Overload range 5.0 HP 6 10 A 7.5 H.P 9 14 A 10 H.P A Type Motor H.P. Overload range GLO-1 3 HP 6-10 A GLO-1 4 HP 6-10 A GLO-1 5 HP 6-10 A GLO-1 6 HP 6-10 A GLO HP 6-10 A GLO-1 10 HP 6-10 A GLO-1 12 HP A GLO HP A GLO-2 20 HP A GLO-2 25 HP A GLO-3 30 HP A GLO-3 40 HP A (4.2) GLO-1 (DOL) Motor H.P. Overload range 3.0 HP 6 10 A 5 H.P 6 10 A 7.5 H.P A (4.3) GLO-1.5 / 2 / 3 (DOL) Motor H.P. Overload range 10 HP A 15 H.P A 20 H.P A 30 H.P A 6 7
7 THREE PHASE DOL ELECTRONIC CONTROL PANEL Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC THREE PHASE STAR DELTA ELECTRONIC CONTROL PANEL Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC (6.1) DIGI : DOL In Built digital volt& Amp meter ( AVM-101) With bright LED phase indication with flash Automatic rotational phase to phase voltage indication Thermal overload protection Short circuit protection through MCB Under voltage protection Phase Failure Protection Auto Start after resumption of Supply Powder coated sheet Metal encloser For 3 phase DOL Submersible/Monoblock Pump set at irrigation, remote farms, unattainable gardening area. Relay Range Amp Amp Amp Amp. (6.2) DCP-9603 Used latest Micro controller based technolgy Electronic Start/Stop push button Inbuilt digital volt & amp Meter Digital display of fault condition Electronic overload protection Under voltage protection Dry Run protection Parameters can be programmed Reverse phasing protection Facility to connect GELCO Water Level Controller Adaptor ( LLC-001D) Remote ON/OFF Powder coated sheet metal enclosure (7.1) DCP-9613 Fully Automatic Star delta starter Used latest micro controller based technology Inbuilt Digital volt /Amp Meter Electronic Overload protection Under Voltage protection Dry run protection Current sensing unit Reverse phase protection Parameters can be programmed Inbuilt Auto ON/OFF timer Powder coated sheet metal enclosure( IP55) Easy to maintain detachable spares Remote ON/OFF For three phase star delta motors used in farms, pumping station, municipal corporation Motor H.P. Overload Overload Motor H.P. range range 7.5 HP 8-20 Amp HP Amp HP 8-20 Amp HP Amp HP 8-20 Amp HP Amp HP Amp HP Amp. Three phase DOL Submersible/Monoblock Pump set for water in residence, commercial, farming, gardening. Current Range 2-5 Amp Amp Amp. 8 9
8 DUTY STAND BY PANEL FOR DUPLEX PUMPS OPERATION STABILIZER (8.1) DUTY STAND BY PANEL FOR DUPLEX PUMPS OPERATION Suitable for Single Phase & Three Phase Power Supply Volt Current and other Fault Conditions Display. Over voltage, under Voltage and Dry run Protection. Pump run and trip indication. Singe Phasing, Current and Voltage Sensing Protection. Selector/Toggle Switch for pump-1 and pump-2 parallel/alternate operation Manual/Auto ON/OFF Sheet metal enclosre with IP-55 Protection Suitable for booster pumps application (9.1) SERVO S e r v o C o n t r o l l e d Vo lta g e Sta b i l i z e r I/P: 170V to 270V (For 1 Phase) 360V to 460V (For 3 Phase) O/P: 215V AC +/- 1% for 1 Phase 415V AC +/- 1% for 3 Phase Capacity: Up to 400 KVA Cooling: Air Cooled Oil Cooled Balance or Unbalance Type, Display Parameter: Digital Volt and Amp. Meter Protection: Over Voltage, Under Voltage, Overload, Single Phasing Prevention Up to 35 HP (9.2) VIOLTEE Model Input Range Output Range Time Delay Application GDMS V AC 270V AC 220V AC ± 10% 10 Sec. Television GDMS V AC 270V AC 220V AC ± 10% 3 Min. Refrigerator DLC V AC 270V AC 210V AC 230V AC 10 Sec. Computer Model Input Range Output Range Time Delay GDMS GDMS GDMS V AC 270V AC 170V AC 270V AC 170V AC 270V AC 220V AC ± 10% 220V AC ± 10% 220V AC ± 10% 3 Min. 3 Min. 3 Min
9 AUTO SWITCH MOTOR STARTER (10.1) Auto Switch Voltage sensing unit Reverse phasing protection Engineering grade plastic enclosure (ABS) Auto ON after resumption of power supply Panel mountable Aux Supply Voltage: 415V AC +/- 20 %, 50 Hz Phase unbalance volt: 45 V +/- 5 V Start Time delay: 1 Minute Output: 1 C/O, 6 Amp (Resi.)@ 230 VAC For MCC of water pumps at remote farms, unattaindable area. (10.2.1) GSW I/P: 230 V, 1Phase, AC Supply ABS Body High/Low voltage protection Over Load Protection Variable current (Amp.) Setting Type GSW-104 GSW-105 GSW-106 GSW-107 GSW-108 Current Range: 2-5 Amp Amp Amp Amp Amp. (10.2.2) GSW-T I/P: 230 V, 1Phase, AC Supply, ABS Body High/Low voltage protection Over Load Protection Time Delay Facility Built in Starter Variable current /AMP setting Relay Type Switching device Type GSW-T-104 GSW-T-105 GSW-T-106 GSW-T-107 GSW-T-108 Current Range: 2-5 Amp Amp Amp Amp Amp
10 A.C. SWITCH PHASE FAILURE RELAY ((10.2.2) AaCcSVCH Input Voltage: 85V Ac To 300V Ac Current Range: 2A to 16A High Voltage Protection : Above 280v High Voltage Cut Off: Below 260v Low Voltage Protection : Below 160v Low Voltage Cut in : Above 175v Over Load Protection programmable range 2A to 16A Time Delay : 60 sec.(1minute) After resumption of power supply Switching device : Relay Unique Alarm system for High voltage, Low voltage, Over load tripping Display of live voltage and live current by seven segment LED Display total run time of your load in hour Air-Conditioner, Television, Refrigerator, Domestic Flour Mill (10.3.1) PFR-104 Micro controller based technology Slim in size Higher accuracy Voltage sensing unit Reverse phasing protection Engineering grade plastic enclosure (ABS) DIN rail mountable Aux Supply Voltage: 415V AC +/- 20 %, 50 Hz Phase unbalance volt: 45 V +/- 5 V Tripping delay: 4 to 7 sec Output: 1 C/O, 6 Amp (Resi.) For MCC of water pumps, generators, compressors (10.3.2) PFR-105 Micro controller based technology Slim in size Higher accuracy Voltage sensing unit Engineering grade plastic enclosure (ABS) DIN rail mountable Aux Supply Voltage: 415 VAC +/- 20 %, 50 Hz Phase unbalance volt: 45 V +/- 5 V Tripping delay: 4 to 7 sec Output: 1 C/O, 6 Amp (Resi.) For MCC of water pumps, generators,compressors 14 15
11 PHASE FAILURE RELAY MOTOR PROTECTION RELAY (10.3.3) PFR-106 Micro controller based technology Slim in size Higher accuracy Voltage sensing unit (PFR 106) Under voltage protection (PFR 106) Reverse phasing protection Engineering grade plastic enclosure (ABS) DIN rail mountable Aux Supply Voltage: 415V AC +/- 20 %, 50 Hz Phase unbalance volt: 45V +/- 5 V Over voltage: Above 480 VAC Under Voltage: Below 320 V Tripping delay: 4 to 7 sec Output: 1 C/O, 6 Amp (Resi.) For MCC of water pumps, generators, compressors, Lift (10.4.1) MGR-101 Current Sensing unit Inverse current characteristics-2 Micro controller based technology Electronic Over load protection DIN rail & Panel Mountable Aux. Supply voltage 415 +/- 20 % VAC Over voltage: 120% +/- 5 V of supply voltage Under Voltage : 80 % +/- 5 V of supply voltage Hysterius Current unbalance Phase-Phase: 50 % of Full Scale current Tripping Delay: 4 to 7 Sec. Dry run : 40% to 80% of Overload Setting MCC Panels of Water Pumps in hilly area. (10.4.2) MGR-102 Current & Voltage Sensing unit Inverse current characteristics-2 Micro controller based technology Electronic Over load protection Under voltage protection Reverse phase protection DIN rail & Panel Mountable Aux. Supply voltage 415 +/- 20 % VAC Over voltage: 120% +/- 5 V of supply voltage Under Voltage : 80 % +/- 5 V of supply voltage Current unbalance Phase-Phase: 50 % of Full Scale current Voltage Unbalance Phase-Phase : 45 +/- 5 V Tripping Delay: 4 to 7 Sec. MCC Panels of water pumps
12 PUMP PROTECTION RELAY ANALOG TIMER (10.5.1) PGR-101 Current Sensing unit Inverse current characteristics Micro controller based technology Electronic Over load protection Under voltage protection Reverse phase protection Output 1 c/o, 6Amp.(Resi) at 230VAC Dry run Protection ( Prodless ) (10.6.1) AC-22 Micro Controller based technology Cyclic timer Easy to programme,through dial on front DIN Rail Mountable Supply: 110/230/415V AC ± 20% 50 Hz, 12/24V AC/DC Output: 2 C/O Relay 230 VAC) Control Action: Cyclic Time Range: 1-10 sec /min/hr. Selectable trough DIP Switch Reset: Power On reset MCC panel for water pumps, compressors, generators, airconditioners (10.5.2) PGR-102 Current & Voltage Sensing unit Inverse current characteristics Micro controller based technology Electronic Over load protection Under voltage protection Reverse phase protection Dry Run protection ( Prodless ) DIN rail & Panel Mountable Aux. Supply voltage 415 +/- 20 % VAC Over voltage: 120% +/- 5 V of supply voltage Under Voltage : 80 % +/- 5 V of supply voltage Current unbalance Phase-Phase: 50 % of Full Scale current Voltage unbalance Phase-Phae : 45 V +/- 5 V Dry Run : 40 % to 80 % of overload setting Tripping Delay: 4 to 7 Sec. (10.6.2) AS-22 Micro Controller based technology Single action timer Delay ON/ OFF timer (Selectable ) Easy to programme,through dial on front DIN Rail Mountable Engineering grade plastic enclosure (ABS) Supply: 110/230/415V AC ± 20% 50 Hz, 12/24V AC/DC Output: 2 C/O Relay 230 VAC) Control Action: Selectable Delay ON/OFF Time Range: 1/3/10/30 sec/min/hr. Selectable trough DIP Switch Reset: Power On reset MCC panel for water pumps, compressors, generators MCC Panels of water pumps in hilly area 18 19
13 ANALOG TIMER DIGITAL TIMER (10.6.3) AS-21 Micro Controller based technology Single Action timer Delay ON/OFF timer (Factory set) Higher Accuracy Easy to programme,through dial on front DIN Rail Mountable (10.6.1) DT-48 Supply: 230V AC ± 20%, 50 Hz Output: 2 C/O Relay 230 VAC) Control Action: Selectable Delay On/Off Time Range: hr./min./sec. Display: 0.4 Seven Segment LED Accuracy: ± 0.01% of FSD Supply: 110/230/415V AC ± 20% 50 Hz, 12/24V AC/DC Output: 1 C/O Relay 230 VAC) Control Action: Delay ON/ Delay OFF Time Range: 0-60 sec Reset: Power On reset MCC panel for water pumps, compressors,generators, airconditioners (10.6.4) SD-22 Micro Controller based technology Star Delta timer Din rail Mountable Higher Accuracy Easy to programme Engineering grade plastic Encloser(ABS) Supply: 110/230/415V AC ± 20% 50 Hz Output: 2 No. 1 C/O (230V AC, 6A) Time Range: y run up time 30/60 sec y to Δ change over time msec Reset: Power On Reset MCC panel for Star Delta pumps set
14 DIGITAL TIME SWITCH EARTH LEAKAGE RELAY (10.7.1) DTS-502 Micro controller based technology On/ Off time is programmable 10 No of programme for On/Off Display of real time clock LED display of unit On Easy to programme Engineering grade plastic enclosure (ABS) Input Supply: 230 +/- 20 % VAC Output Supply: 230 +/- 20 % VAC Capacity: 20 amp at 230 VAC (Resi.) Water pump, Street lights (10.8.1) ELR-101 Micro Controller Based technology Higher precision Panel/Surface mountable Parameters are settable through knob in front panel Engineering grade plastic enclosure( ABS) With CBCT Auxiliary Supply: 110/280/415v, 50 HZ, Relay Contact: 1 C/O contact with 6 Amp. Resistive load at 230v AC, Leakage Current Range: 30 to 100 ma 0.1 to 1 Amp 0.5 to 5 Amp. Reset: Manual Operating Temp. : -5 C to 60 C (10.7.2) DTS-601 Micro controller based technology On/ Off time is programmable CBCT : 70,100,200,300 & 400mm Distribution panels for hotels, commercial complex, residential blocks, industrial complex. Mining industry 10 No of programme for On/Off Display of real time clock LED display of unit On Easy to programme Engineering grade plastic enclosure (ABS) Input Supply:415 +/- 20 % VAC Output :Potential Free 1 Contact,6 amp at 230 VAC (Resi.) Water pump, street lights 22 23
15 EARTH LEAKAGE RELAY EARTH LEAKAGE CIRCUIT BREAKER (10.8.2) ELR-9601 Micro Controller Based technology Higher precision DIN standard flush mountable(92x92) Digital display of leakage current Parameters are programmable Engineering grade plastic enclosure( ABS) With CBCT (10.9.1) EL+MCB Load Current Rating: 16A / 25A / 32A System Voltage: 230V AC, 1 Phase, 50Hz, Sensitivity: 3-50 ma, Tripping Time: <30 ms. High/Low Voltage Cut off, Overload Short Circuit Protection Supply Voltage : V AC/DC, 50/60 Hz 415V AC, 50Hz ± 15% Relay contact : 1 change over Potential free contact Positive safety output (Relay will energies on fault) Contact Rating: 6A at 230V AC / 30V DC Leakage current range : mA Trip time set: 0.05 to 5 Sec. Display: Digital 7seg. LED display Operating temp. : -5 c to 60 c CBCT 70, 100, 200, 300 & 400mm Distribution panels for hotels, commercial complex, residential blocks, industrial complex. Mining industry
16 PANEL METERS AUTOMATIC LIGHT CONTROLLER (10.10) AVM-101 Micro Controller Based technology Inbuit C.T. Indicates phase phase voltage Indicates system current Indication for phase through high bright LED Voltage indiaction rotate at fixed interval for different phase-phase Panel mountable Aux. Supply : 415 +/- 20 % VAC Amp. Range : 4-40 Amp, Amp ( ) AUTOPHOTO Type AMPR PHASE APPLICATION ALC 6 ( I ) 1 6 Amp 1 Phase Indoor application ALC 10 ( I ) 1 10 Amp 1 Phase Indoor application ALC 10 ( O ) 1 10 Amp 1 Phase Indoor application ALC 25 ( I ) 1 25 Amp 1 Phase Indoor application ALC 25 ( O ) 1 25 Amp 1 Phase Indoor application ALC 16 ( O ) 3 16 Amp 1 Phase Indoor application ALC 32 ( O ) 3 32 Amp 1 Phase Indoor application ALC 63 ( O ) 3 63 Amp 1 Phase Indoor application Control Panels for housing, water pumps, industries, residential complex etc
17 SPP WITH WATER LEVEL GUARD WATER LEVEL CONTROLLER ( ) SWG Phase failure relay with dry run protection ( with Prod) Voltage sensing unit Under voltage protection Engineering grade plastic (HIPS) enclosure Panel mountable Available with S.S. Sensor. Aux Supply: 415 +/- 20 % VAC, 50 Hz Output : 1 C/O, 230 AC (Resi.) Over voltage: Above 480 VAC Under voltage : Below 320 VAC MCC for sewage pumps ( ) LLC-101 Easy to install DIN rail/ Panel mountable Two tank controller Automatic control of starter according to set water level in tanks LED indications for water level in tank Specially for three phase motor starters Availabe with S.S Sensors/Magnetic sensors/float switch System Voltage: 415 VAC +/- 20 %, 50 Hz Output : 1 CO contact,1 Amp. At 415 VAC, Pf=0.5 MCC of water pump in hotels, housed, high rise towers, societies, industries, commercial complexes, municipal water stations. ( ) LLC-2 Easy to install Panel mountable Two tank controller Automatic control of starter according to set water level in tanks LED indications for water level in tank Specially for single phase motor starters Availabe with S.S Sensors/Magnetic sensors/float switch System Voltage: 230 VAC +/- 20 %, 50 Hz Output Voltage: 230 VAC +/- 20 %, 50 Hz Capacity 30 A at 230 VAC ( Resi.) MCC of water pump in hotels, housed, high rise towers, societies, industries, commercial complexes, municipal water stations
18 WATER LEVEL CONTROLLER ( ) LLC-2S Easy to install Two tank controller Automatic control of starter according to set water level in tanks LED indications for water level in tank Specially for single phase submersible semi automatic motor starters Availabe with S.S Sensors/Magnetic sensors/float switch System Voltage: 230 VAC +/- 20 %, 50 Hz Output Voltage: 230 VAC+/- 20 %, 50 Hz Capacity 30 A at 230 VAC ( Resi.) MCC of water pump in hotels, housed, high rise towers, societies, industries, commercial complexes, municipal water stations. ( ) LLC-001/LLC-001D Water Level controller adopter Usefull with GELCO make single or three phase DOL or FASD starters having adopter facility only Easy to install Panel mountable Two tank controller Automatic control of starter according to set water level in tanks LED indications for water level in tank Availabe with S.S Sensors/Magnetic sensors/float switch Engineering grade plastic enclosure (ABS) For GELCO starter having micro controller based technology use LLC-001 D Motor starter of water pump in hotels, housed, high rise towers, societies, industries, commercial complexes, municipal water stations
19 32
From the dawn of Excellence emanates the high noon of Performance.
From the dawn of Excellence emanates the high noon of Performance. Gelco Electronics is a full service electronic company that manufactures superior quality electronic control and switchgear products &
More informationSeries Motor Protection
320-327 Series Motor Protection Relay Physical Address: 298 Soutter Street, Pretoria West Tel: 083 454 6949, +27 12 327 1729 Fax: +27 (0)12 327 1733 Toll Assist: 0860 10 30 41 www.newelec.co.za sales@newelec.co.za
More informationMicro Controller based Motor Protection Relay & Motor Management System
Micro Controller based Motor Protection Relay & Motor Management System Micro Controller based Motor Protection Relay :WOD-TUA Features : In built three Phase CTs Extra wide Range : 1 10 A / 7 20 A In
More informationMetering Products. Metering Products Protection Units April 1, Price List. Price List. With effect from April 1,
Price List Metering Products Metering Products Protection Units With Current effect from Transformers April, 20 With effect from April,20 E-mail: marketing@veritekindia.com Telephone: 022-6294268 Sr.No
More informationAmbilin Incorporate.
+91-8048601923 Ambilin Incorporate https://www.ambilincontrolpanel.com/ We are amongst the leading organizations engaged in manufacturing of Submersible Pump Panel, Digital Meter, Single Phase Digital
More informationMetering Products Protection Units Current Transformers. April 1, 2015
Metering Products Protection Units Current Transformers April, 0 With Effect From April, 0 Sr.No Description Model No. Multifunction LED Meters POWER ANALYZER - LED VIPS 80P 00 POWER ANALYZER - LED 0-
More informationStarters. Overview. Siemens caters with following types of starters to agricultural and industrial sector.
Starters Overview Siemens caters with following types of starters to agricultural and industrial sector. 55 Application The main purpose of motor starters is to start the electrical motor by switching
More informationM440 MOTOR PROTECTION, EARTH FAULT LOCKOUT & MANAGEMENT RELAY VERSION 3.5 NINGI SERVICES (PTY) LTD
M440 MOTOR PROTECTION, EARTH FAULT LOCKOUT & MANAGEMENT RELAY VERSION 3.5 NINGI SERVICES (PTY) LTD TOLL FREE 0800 000 400 TEL 013 692 3372 FAX 013 692 3392 CELL 082 556 7682 1 Presenting the UM440U Motor
More informationLA Motor Protection. A South African Company to be Proud of
LA Motor Protection Relay Physical Address: 298 Soutter Street, Pretoria West Tel: 083 454 6949, +27 12 327 1729 Fax: +27 (0)12 327 1733 Toll Assist: 0860 10 30 41 www.newelec.co.za sales@newelec.co.za
More informationKD LV Motor Protection Relay
1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage
More informationPart # Features & Applications Specifications Cross Reference
Solid State Controls 24-ICM450 24-ICM400 Fully Programmable - with LCD diagnostic display. Easy to configure - simple 7-step push-button setup. Easy to customize - set points, variables and features are
More informationDIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES
PROK DEVICES PRIVATE LIMITED B-80, 2 nd & 3 rd Floor, KSSIDC Industrial estate, 4 th Main Road, 6 th Block, Rajaji Nagar, Bengaluru -560010 Ph no: 080-41480777, 080-41157700, Email:,, www.prokdvs.in DIP
More informationRotomatik Corporation
+91-8048736973 Rotomatik Corporation https://www.rotomatik.in/ We are a prominent manufacturer and trader of Gear Pump, Stainless Steel Pump, Industrial Pump and much more. These products are appreciated
More informationICG Switchgear Price List 2009
ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section
More informationFranklin Electric Submersible Motors SUBMERSIBLE MOTORS. Motors Accessories. Product Information and Service
Franklin Electric Submersible Motors SUBMERSIBLE MOTORS Motors Accessories Product Information and Service Table of contents 4" Encapsulated Sacrifical Anode Kit Descriptions / Modelnumbers 01 Lead 4"
More informationTENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID
TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID S.NO. HEAD DESCRIPTION AMOUNT (Rs.) 1 A DG SETS & ACCESSORIES
More informationApplication Engineering
Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor
More informationBulletin 825 SMM Smart Motor Manager
Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.
More informationTOTALINE PROTECTION CONTROLS
TOTALINE PROTECTION CONTROLS SOLID STATE HEAD PRESSURE CONTROL WITH OPTIONAL HEAT PUMP OVERRIDE Head Pressure Controls Temperature sensitive fan motor control which regulates head pressure at low ambients
More informationQuality Products, Prompt Service, Trustful Relationships.
SINCE 1989 Quality Products, Prompt Service, Trustful Relationships. KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry Goods for the last 20 years.
More informationCI-tronic Soft Start Motor Controller Type MCI 25B with Brake
Data sheet CI-tronic Soft Start Motor Controller Type MCI 25B with Brake MCI 25B motor controller with brake is designed for soft starting and braking of 3 phase AC motors. The digital controlled soft
More informationApplication Engineering
Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the
More informationDesigned for ease of integration with automation systems
BAS, 200 ~ 600V, 1/2-30HP BUILDING AUTOMATION STARTER SMARTER AND MORE VERSATILE THAN EVER Smartstart Equipped with advanced I/O including Fireman s Override and damper control, the BAS was designed from
More informationGCU-10. Automatic Engine Control Unit Operators Manual
GCU-10 Automatic Engine Control Unit Operators Manual KUTAI ELECTRONICS INDUSTRY CO., LTD. TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw Headquarters : No.3, Lane 201, Chien Fu St.,
More informationPRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY
Sheet 1 of 5 Order Number Serial Number PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Issue Date Level B 27/05/1999 Initial issue. Summary of changes Due to RMS continuous product improvement policy
More informationDRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...
100HP 400HP 700HP 1000HP 1400HP PCS Softstarter Controller IN-rail mountable microprocessor controller for 3-phase motors up to 480A (3...85A din-rail mountable) Provides three different starting modes
More informationBurden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM
Contents Section Page 1.0 Introduction 1 2.0 Specification 1-4 3.0 Installation 5-8 4.0 Programming 9-10 5.0 Menus 10-12 6.0 Fault Finding/Diagnostics 12-13 7.0 Communication 13 8.0 Setting Up 13-16 1.0
More information2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4
CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power
More informationXM1 - Motor protection relay
XM1 - Motor protection relay Contents 1 Applications and features 1 Applications and features 2 Design 3 Working principle 3.1 Overload protection 3.2 Stalling protection 3.3 Earth fault protection 3.4
More informationSALES PRESENTATION FOR RELAYS, CONTACTORS & MOTOR STARTER TESTING EQUIPMENTS
SALES PRESENTATION FOR RELAYS, CONTACTORS & MOTOR STARTER TESTING EQUIPMENTS Relay Test Bench: LIST OF TEST EQUIPMENT 1. FIVE STATION BIMETAL OVERLOAD RELAY TEST BENCH 2. TWENTY FOUR STATION RELAY HEATING
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationOpen Chassis Star-Delta Starter User Guide
Open Chassis Star-Delta Starter User Guide (7.5kW~90kW) V2.0.1 Contents 1 Safety information... 1 2 Technical Data... 2 3 Supply & Motor Connections & Circuit Diagrams... 5 4 Control Connections & Operation...
More informationB BASIC HEAT TREATMENT CONSOLE
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More informationVariable Speed Product Line
Variable Speed Product Line BRCPVFD R1 Variable Speed Product Line Since 1997, CentriPro has been providing variable speed pump control solutions to its customers. The first product was the Aquavar variable
More informationMCD Pump Application Module
Overview The Pump Application Module expands the soft starter's input and output functionality and is ideal for applications where greater control and feedback are required. The module provides three digital
More informationContactors and Overloads MC
Contactors and Overloads MC Up to 700A AC3 Up to 00A AC1 DIN rail mounting to 5A, 55kW Add on auxiliary contacts top or side mounted International approvals Designed to EN60971 Compact design for panel
More informationTDX - Taco Duplex Starter with
Energy Management TDX - Taco Duplex Starter with Smartstart The TDX extends the life of your pumps by alternating control. It comes standard with underload protection, a enhanced class 10 electronic overload
More informationMODEL 422 Submersible Pump Controller
MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and
More informationDefining a timer in simple terms. Which actions are executed? Which market are they used frequently? Benefits and Advantages
Z Series Timers Defining a timer in simple terms A timer is an automation device that either keeps track of how much time has been spent doing something or that counts down a specif ied duration of time.
More informationTECHNOLOGICALLY ADVANCED ENERGY PRODUCTS. Product Preview & Price List 2018
TECHNOLOGICALLY ADVANCED ENERGY PRODUCTS Product Preview & Price List 2018 Price effective: November, 2018 SMART ENERGY MANAGEMENT POWER QUALITY MANAGEMENT POWER DISTRIBUTION MANAGEMENT SECURITY & ACCESS
More informationCI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O
Data sheet CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus
More informationInstallation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor
World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com
More informationSDS Enclosed Star-Delta Starter User Guide
SDS Enclosed Star-Delta Starter User Guide (7.5kW~90kW) V2.0.0 PLEASE NOTE: AS STANDARD AND UNLESS OTHERWISE SPECIFIED, THIS PRODUCT IS EQUIPPED WITH A BASIC LOW INTEGRITY EMERGENCY STOP CIRCUIT STOPPING
More informationRE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW
Page 1 of 6 3-Phase Panel Mount 86 and 105kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting Efficient
More informationNOCCHI FREQUENCY CHANGER PRESSURE BOOSTERS WITH VARIABLE SPEED
NOCCHI FREQUENCY CHANGER PRESSURE BOOSTERS WITH VARIABLE SPEED Lenntech info@lenntech.com Tel. +31-152-61-9 www.lenntech.com Fax. +31-152-616-289 SILENT OPERATION, CONSTANT PRESSURE, PIPELINES IN AISI
More informationObserve all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.
Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary
More informationData sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443
CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O December 2002 DKACT.PD.C50.G2.02 520B1443 2 DKACT.PD.C50.G2.02 Danfoss A/S 12-2002 Introduction The MCI soft starters
More informationOPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,
More information32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide
32XR 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide RED ALARM LIGHT LEVEL CONTROLLER H-O-A SWITCHES HORN SILENCE INNER DOOR MOTOR STARTERS WITH INTERCHANGEABLE OVERLOAD MODULES
More information331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH
331-SV User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER Ashland, OH 800-363-5842 WWW.PRIMEXCONTROLS.COM Warranty void if panel is modified. Call factory with servicing
More informationEPS-ECONOMY PUMP STARTER
EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides
More informationELECTRICAL SYSTEM RP-7
ELECTRICAL SYSTEM RP-7 This section of the manual does not include integral electrical components of the engine. Refer to section Engine RP-1 for details. This section of the manual is divided into three
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationHOTLINE ELECTRICAL TRADING
HOTLINE ELECTRICAL TRADING (L.L.C) P.O.Box: 235152 Dubai, UAE. Tel ; +971-4-3455173 Email:-manuel@hletllc.com I www.hletllc.com Company Profile Hotline Electrical Trading L.L.C is a trading company dealing
More informationCascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75
Cascade CD101 Auto-Start Controller Installation and Operations Manual 00-02-0594 2018-02-15 Sections 40 & 75 In order to consistently bring you the highest quality, full featured products, we reserve
More informationCG PRESSURE BOOSTING SYSTEMS
CG PRESSURE BOOSTING SYSTEMS Pumps Division An Overview CGL PUMPS : A REPUTATION FOR EXCELLENCE... Crompton Greaves Ltd, is an Indian MNC, a part of US$4 BN Avantha Group conglomerate with an impressive
More informationType CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay
Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay DG 14 drawn out from the case The type DG 14 relay is a heavily damped
More informationDesigned for Today s World
www.fgwilson.com 24 220 KVA RANGE Performance I Durability I Serviceability Designed for Today s World The world we live in never stops changing, so neither do we. Our newest power range, 24 220 kva,
More informationProduct selection table
Product selection table Equipment Protection Reclosure Associated circuit breaker External toroidal Page REC2 Earth leakage switch -- 47 WRU RA Contactor -- 49 WRU-10 RAL Contactor -- 51 RGU-10 RAL Contactor
More informationDesigned for Today s World
www.fgwilson.com 24 220 kva Range Performance I Durability I Serviceability Designed for Today s World The world we live in never stops changing, so neither do we. Our newest power range, 24 220 kva,
More informationCI-TI Contactors and Motor Starters Type CI 6-50
Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components
More informationHydrovar and Packaged Hydrovar
Hydrovar and Packaged Hydrovar MOTOR MOUNT VARIABLE SPEED PUMP CONTROLLER AND INTEGRATED PUMP PACKAGES BRHYDROVAR R3 Goulds Water Technology Hydrovar and Packaged Hydrovar Hydrovar Variable Speed Drives
More informationThe University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6
The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 6 PROTECTIONS 1 FUNCTION OF ELECTRICAL PROTECTION SYSTEMS Problems:
More informationCONSTANT PRESSURE CONTROLLERS
CONSTANT PRESSURE CONTROLLERS SUBDRIVE AND MONODRIVE Franklin Electric s SubDrive and MonoDrive constant pressure controllers provide constant pressure by continually adjusting the speed of the pump to
More informationMINIATURE CIRCUIT BREAKER
Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.
More informationSINGLE-PHASE PUMP START AND PROTECTION BOX Type V1M, V1N, V1E, V1F
www.motor-pump-ventilation.com SINGLE-PHASE PUMP START AND PROTECTION BOX Type V1M, V1N, V1E, V1F Owner s manual Main features An all-in-one control and protection unit for any pump. Multicontrol. Vigilec
More informationContents. We build a better future! MCC HCB
H8PU Low Voltage We build a better future! HYUNDAI s low voltage motor control center H8PU series with a withdrawable unit are of multi-tier, factory assembled and for rated voltage of up to 660V AC. Contents
More information825-P Modular Protection System for motors Specification Guide
Specification Guide 1.0 General 1.01 The motor protection relay shall have a current operating range of 0.5 and 5000 amperes. 1.02 The motor protection relay shall provide current measurement-based protection
More informationDesigned for Today s World
www.fgwilson.com 24 220 KVA RANGE Performance I Durability I Serviceability Designed for Today s World The world we live in never stops changing, so neither do we. Our newest power range, 24 220 kva,
More informationElectromagnetic Industries LLP
GROUND FAULT CURRENT DETECTION GFM Relay (Model 252 & 262) The GFM system is designed for electrical protection, not for personnel protection Application: These Class 1 (Model GFM) Ground Fault protection
More informationUNIVERSAL PRODUCT RANGE. Performance I Durability I Serviceability
UNIVERSAL PRODUCT RANGE Performance I Durability I Serviceability The Universal range of generator sets is designed to power your every need. With an enhanced choice of power nodes, this range is engineered
More informationSDM72 Start on Demand Modules
Capricorn Controls DA04SDM72-2 Revised Design Page 1 of 6 SDM72 Start on Demand Modules Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom Products Application
More informationBRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life
ITT BRSDRIVE Goulds Pumps Simplex Variable Speed Submersible Pump Controller C U L US Engineered for life Do you want to Simplify your Commercial Pumping System? Goulds Pumps S-Drive variable speed, constant
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series
More informationICON 2 1. FEATURES AND CHARACTEIRICS
ICON 2 1. FEATURES AND CHARACTEIRICS High end Micro-controller(DSP) technology Wide range of auxiliary supply: 7V to 45Vdc. Low power Consumption : 200 ma @ 12 V DC. Alphanumeric 16X4 or 16X2 LCD display
More informationDIGITAL EARTH LEAKAGE RELAY
EARTH LEAKAGE (ELR) WITH CORE BALANCE Features ŸDigital Microprocessor / Microcontroller based compact design. ŸContinuous monitoring and display of set value and measured value of leakage current. Ÿ8
More informationLegat-65. Voltage Stabilizer Technical Certificate. NOVATEK-ELECTRO LTD Research-and-Manufacture Company
NOVATEK-ELECTRO LTD Research-and-Manufacture Company Legat-65 Voltage Stabilizer Technical Certificate www.novatek-electro.com 1. Application Legat-65 single-phase voltage stabilizer, hereinafter referred
More informationADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED
ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL Dual Rating NRTL/C CERTIFIED Technologies Inc. mgitech.com Sensor/Sensorless Vector Control Dual current rated for constant and variable torque Auto
More informationCP Automatic capacitor bank
CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor
More informationGenerator Controller Manual
Generator Controller Manual Web Site:http://www.monicon.com.tw E-mail:sales@monicon.com.tw 1. Controller Description is low cost but multi-function diesel engine generator controller. It applies with 3
More informationSoft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP
Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user
More informationNew range of reclosing systems
Protection and Control RECmax New range of reclosing systems Earth leakage and circuit breaker protection with automatic earth leakage reclosing system. Manage its installation remotely Energy efficiency
More informationMoulded Case Circuit Breakers
Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field
More informationPHASE PERFECT PHASE CONVERTERS OPERATION & INSTALLATION MANUAL PHASE TECHNOLOGIES, LLC
PHASE PERFECT PHASE CONVERTERS OPERATION & INSTALLATION MANUAL PHASE TECHNOLOGIES, LLC 1 DANGER: HIGH VOLTAGE Electric shock could result in death or injury. qualified personnel for installation. Please
More informationwww.ic-electronic.com Soft starter with integrated Motor Protection, Current and Voltage control Single phase controlled with internal by-pass ated operational Voltage 230VAC Frequency 45... 65Hz Self
More informationSECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.
SECTION 16904 MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS PART 2 PRODUCTS 01 MANUFACTURERS A. B. C. Eaton * * The listing of specific manufacturers above does not imply acceptance of their products
More informationSD Series Non-Fused Load Switches
SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load
More informationABB Softstarter Benefits Charnchanok Thongprad
ABB Softstarter Benefits Charnchanok Thongprad tomation Technology Products AB Control - 1 - - Why Softstarters? Benefits for the Electrical network Reduces voltage drops on networks Minimizes starting
More information1 Phase electronic contactor (SC 1)
1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or
More informationAuto Mains Failure AMF Controller AE10113
Auto Mains Failure AMF Controller AE03 Auto Mains Failure DESCRIPTION AMF Controller AE03 is an Automatic Mains Failure controller, which activates the generator during power failure & vice versa. The
More informationINSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY
CONNECTIONS INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION!! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS
More informationpower made simple kva RANGE Performance I Durability I Serviceability
power made simple www.fgwilson.com 8.5 290 kva RANGE Performance I Durability I Serviceability Modern life is complicated but ensuring your power supply can be simple with FG Wilson. Our latest product
More informationMoulded case circuit breakers
Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded
More informationElectronic timers CT-S range Function diagrams
CT-S range Function diagrams - X1-Z2 = ON- delay CT-ERS, CT-MBS, CT-MFS t = set delay time / ts = storing time; t = t1 + t2 = OFF-delay CT-AHS, CT-MBS, CT-MFS X1-Z2 t = set delay time / ts = storing time;
More informationGRUNDFOS PRODUCT GUIDE. Redi-Flo3 and CU 300. Environmental Pumps 60Hz
GRUNDFOS PRODUCT GUIDE Redi-Flo3 and CU 300 Environmental Pumps 60Hz Table of Contents Features and Benefits..................................... pages 4-5 Applications.............................................
More informationAQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2
AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2 INTRODUCTION The Aquavar Intelligent Pump Controller from utilizes an all new Aquavar platform, and combines it with over 20 years of
More information60 Series Engine Controls
ECU 60 Series Engine Controls Use CAUTION since you are applying 120VAC RMS to the AC Input terminals and that it is always potentially their during engine run!!! ECU is a registered trademark of Engineering
More informationNOVATEK-ELECTRO LTD Research-and-Manufacture Company SINGLE PHASE VOLTAGE MONITORING RELAY RN-113 USERS MANUAL
LTD Research-and-Manufacture Company SINGLE PHASE VOLTAGE MONITORING RELAY USERS MANUAL 1.APPLICATION Voltage monitoring relay (hereinafter ) is designed to turn OFF home used consumer equipment or industrial
More informationVOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS
VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.
More informationcanfield connector 8510 Foxwood Court Youngstown, Ohio (330) Fax: (330)
canfield connector 8510 Foxwood Court Youngstown, Ohio 44514 (330) 758-8299 Fax: (330) 758-8912 www.canfieldconnector.com MODEL MBT MULTIFUNCTION BLOCK TIMER 12 FUNCTIONS IN 1 TIMER General Description
More information