1 B Product page Miniature circuit breakers (MCB) - Hager B Hager B-5 6 Earth leakage protection - Socomec B-21 - Lovato B-43 Modular isolators - Fanox B-44 - Hager B-7 Modular relays / contactors - Hager B-8 Modular time switches - Hager B-9 - Hager B-10 Surge protection devices (SPD) - CPT B Dehn B-48 Moulded case circuit breakers (MCCB) - Hager B Air circuit breakers (ACB) - Hager B Load break switches (Isolators) - Socomec B Lovato B Changeover switches - Socomec B Fuse switches - Socomec B-32 Fuses and bases - DF B Power supplies - Delta B Lovato B-51 Transformers - DF B-52

2 Miniature circuit breakers (MCBs) 6/10kA For the protection and control of circuits against overload and short circuits. Suitable for commercial and industrial installations. Breaking capacity: Field fittable accessories (see page B-5) SANS / IEC kA auxiliary/alarm contacts IEC KA shunt trip device undervoltage release Voltage rating: 240/400V 50-60Hz earth leakage designation current breaking width in rating capacity 17.5mm NF116A NF / HLF series 10kA C curve (5-10 In) Single pole NF100A 0.5A 10kA miniature circuit breaker PP NF101A 1A 10kA miniature circuit breaker NF102A 2A 10kA miniature circuit breaker NF103A 3A 10kA miniature circuit breaker NF106A 6A 10kA miniature circuit breaker NF110A 10A 10kA miniature circuit breaker NF116A 16A 10kA miniature circuit breaker NF120A 20A 10kA miniature circuit breaker NF125A 25A 10kA miniature circuit breaker NF132A 32A 10kA miniature circuit breaker NF140A 40A 10kA miniature circuit breaker NF150A 50A 10kA miniature circuit breaker NF163A 63A 10kA miniature circuit breaker HLF180S 80A 10kA miniature circuit breaker HLF190S 100A 10kA miniature circuit breaker HLF199S 125A 10kA miniature circuit breaker Two pole NF202A 2A 10kA miniature circuit breaker PP NF203A 3A 10kA miniature circuit breaker NF206A 6A 10kA miniature circuit breaker NF210A 10A 10kA miniature circuit breaker NF216A 16A 10kA miniature circuit breaker NF220A 20A 10kA miniature circuit breaker NF225A 25A 10kA miniature circuit breaker NF232A 32A 10kA miniature circuit breaker NF240A 40A 10kA miniature circuit breaker NF250A 50A 10kA miniature circuit breaker NF263A 63A 10kA miniature circuit breaker NF232A HLF280S 80A 10kA miniature circuit breaker HLF290S 100A 10kA miniature circuit breaker HLF299S 125A 10kA miniature circuit breaker Triple pole NF302A 2A 10kA miniature circuit breaker PP NF303A 3A 10kA miniature circuit breaker NF306A 6A 10kA miniature circuit breaker NF310A 10A 10kA miniature circuit breaker NF316A 16A 10kA miniature circuit breaker NF320A 20A 10kA miniature circuit breaker NF325A 25A 10kA miniature circuit breaker NF332A 32A 10kA miniature circuit breaker NF340A 40A 10kA miniature circuit breaker NF350A 50A 10kA miniature circuit breaker NF363A 63A 10kA miniature circuit breaker HLF380S 80A 10kA miniature circuit breaker HLF390S 100A 10kA miniature circuit breaker HLF399S 125A 10kA miniature circuit breaker Four pole NF406A 6A 10kA miniature circuit breaker PP NF410A 10A 10kA miniature circuit breaker NF416A 16A 10kA miniature circuit breaker NF420A 20A 10kA miniature circuit breaker NF425A 25A 10kA miniature circuit breaker NF432A 32A 10kA miniature circuit breaker NF440A 40A 10kA miniature circuit breaker NF450A 50A 10kA miniature circuit breaker NF463A 63A 10kA miniature circuit breaker NF320A HLF480S 80A 10kA miniature circuit breaker HLF490S 100A 10kA miniature circuit breaker HLF499S 125A 10kA miniature circuit breaker B-1

3 Miniature circuit breakers (MCBs) 10/15kA D curve NDN116A For the protection and control of circuits against overload and short circuits. Suitable for commercial and industrial installations. Breaking capacity: Field fittable accessories (see page B-5) SANS / IEC NDN: 10kA - auxiliary/alarm contacts HMD: 15kA - shunt trip device - undervoltage release Voltage rating: 240/400V 50-60Hz - earth leakage designation NDN / HMD series 10/15kA current breaking width in rating capacity 17.5mm D curve (10-20 In) Single pole NDN106A 6A 10kA miniature circuit breaker PP NDN110A 10A 10kA miniature circuit breaker NDN116A 16A 10kA miniature circuit breaker NDN120A 20A 10kA miniature circuit breaker NDN125A 25A 10kA miniature circuit breaker NDN132A 32A 10kA miniature circuit breaker NDN140A 40A 10kA miniature circuit breaker NDN150A 50A 10kA miniature circuit breaker NDN163A 63A 10kA miniature circuit breaker HMD180 80A 15kA miniature circuit breaker HMD A 15kA miniature circuit breaker HMD A 15kA miniature circuit breaker HMD180 Two pole NDN206A 6A 10kA miniature circuit breaker PP NDN210A 10A 10kA miniature circuit breaker NDN216A 16A 10kA miniature circuit breaker NDN220A 20A 10kA miniature circuit breaker NDN225A 25A 10kA miniature circuit breaker NDN232A 32A 10kA miniature circuit breaker NDN240A 40A 10kA miniature circuit breaker NDN250A 50A 10kA miniature circuit breaker NDN263A 63A 10kA miniature circuit breaker HMD280 80A 15kA miniature circuit breaker HMD A 15kA miniature circuit breaker HMD A 15kA miniature circuit breaker NDN363A Triple pole NDN306A 6A 10kA miniature circuit breaker PP NDN310A 10A 10kA miniature circuit breaker NDN316A 16A 10kA miniature circuit breaker NDN320A 20A 10kA miniature circuit breaker NDN325A 25A 10kA miniature circuit breaker NDN332A 32A 10kA miniature circuit breaker NDN340A 40A 10kA miniature circuit breaker NDN350A 50A 10kA miniature circuit breaker NDN363A 63A 10kA miniature circuit breaker HMD380 80A 15kA miniature circuit breaker HMD A 15kA miniature circuit breaker HMD A 15kA miniature circuit breaker HMD399 Four pole NDN406A 6A 10kA miniature circuit breaker PP NDN410A 10A 10kA miniature circuit breaker NDN416A 16A 10kA miniature circuit breaker NDN420A 20A 10kA miniature circuit breaker NDN425A 25A 10kA miniature circuit breaker NDN432A 32A 10kA miniature circuit breaker NDN440A 40A 10kA miniature circuit breaker NDN450A 50A 10kA miniature circuit breaker NDN463A 63A 10kA miniature circuit breaker HMD480 80A 15kA miniature circuit breaker HMD A 15kA miniature circuit breaker HMD A 15kA miniature circuit breaker B-2

4 Miniature circuit breakers (MCBs) 10/15kA For the protection and control of circuits against overload and short circuits. Suitable for commercial and industrial installations. Breaking capacity: Field fittable accessories (see page B-5) SANS / IEC kA - auxiliary/alarm contacts IEC kA - shunt trip device - undervoltage release Voltage rating: 240/400V 50-60Hz - earth leakage designation current breaking width in rating capacity 17.5mm NCN116A NCN / HMC series 10/15kA C curve (5-10 In) Single pole NCN106A 6A 15kA miniature circuit breaker PP NCN110A 10A 15kA miniature circuit breaker NCN116A 16A 15kA miniature circuit breaker NCN120A 20A 15kA miniature circuit breaker NCN125A 25A 15kA miniature circuit breaker NCN132A 32A 15kA miniature circuit breaker NCN140A 40A 15kA miniature circuit breaker NCN150A 50A 15kA miniature circuit breaker NCN163A 63A 15kA miniature circuit breaker HMC180 80A 15kA miniature circuit breaker HMC A 15kA miniature circuit breaker HMC A 15kA miniature circuit breaker NCN232A Two pole NCN206A 6A 15kA miniature circuit breaker PP NCN210A 10A 15kA miniature circuit breaker NCN216A 16A 15kA miniature circuit breaker NCN220A 20A 15kA miniature circuit breaker NCN225A 25A 15kA miniature circuit breaker NCN232A 32A 15kA miniature circuit breaker NCN240A 40A 15kA miniature circuit breaker NCN250A 50A 15kA miniature circuit breaker NCN263A 63A 15kA miniature circuit breaker HMC280 80A 15kA miniature circuit breaker HMC A 15kA miniature circuit breaker HMC A 15kA miniature circuit breaker NCN320A Triple pole NCN306A 6A 15kA miniature circuit breaker PP NCN310A 10A 15kA miniature circuit breaker NCN316A 16A 15kA miniature circuit breaker NCN320A 20A 15kA miniature circuit breaker NCN325A 25A 15kA miniature circuit breaker NCN332A 32A 15kA miniature circuit breaker NCN340A 40A 15kA miniature circuit breaker NCN350A 50A 15kA miniature circuit breaker NCN363A 63A 15kA miniature circuit breaker HMC380 80A 15kA miniature circuit breaker HMC A 15kA miniature circuit breaker HMC A 15kA miniature circuit breaker Four pole NCN406A 6A 15kA miniature circuit breaker PP NCN410A 10A 15kA miniature circuit breaker NCN416A 16A 15kA miniature circuit breaker NCN420A 20A 15kA miniature circuit breaker NCN425A 25A 15kA miniature circuit breaker NCN432A 32A 15kA miniature circuit breaker NCN440A 40A 15kA miniature circuit breaker NCN450A 50A 15kA miniature circuit breaker NCN463A 63A 15kA miniature circuit breaker NCN440A HMC480 80A 15kA miniature circuit breaker HMC A 15kA miniature circuit breaker HMC A 15kA miniature circuit breaker B-3

5 High fault level (MCBs) 15/20/25kA NRN116A NRN232A NRN320A For the protection and control of circuits against overload and short circuits. Suitable for commercial and industrial installations. Breaking capacity: Field fittable accessories (see page B-5) SANS / IEC A 25kA - auxiliary/alarm contacts 32-40A 20kA - shunt trip device 50-63A 15kA - undervoltage release - earth leakage Voltage rating: 240/400V 50-60Hz designation NRN series 15-25kA C curve (5-10 In) current breaking width in rating capacity 17.5mm Single pole NRN106A 6A 25kA miniature circuit breaker PP NRN110A 10A 25kA miniature circuit breaker NRN116A 16A 25kA miniature circuit breaker NRN120A 20A 25kA miniature circuit breaker NRN125A 25A 25kA miniature circuit breaker NRN132A 32A 20kA miniature circuit breaker NRN140A 40A 20kA miniature circuit breaker NRN150A 50A 15kA miniature circuit breaker NRN163A 63A 15kA miniature circuit breaker Two pole NRN206A 6A 25kA miniature circuit breaker PP NRN210A 10A 25kA miniature circuit breaker NRN216A 16A 25kA miniature circuit breaker NRN220A 20A 25kA miniature circuit breaker NRN225A 25A 25kA miniature circuit breaker NRN232A 32A 20kA miniature circuit breaker NRN240A 40A 20kA miniature circuit breaker NRN250A 50A 15kA miniature circuit breaker NRN263A 63A 15kA miniature circuit breaker Triple pole NRN306A 6A 25kA miniature circuit breaker PP NRN310A 10A 25kA miniature circuit breaker NRN316A 16A 25kA miniature circuit breaker NRN320A 20A 25kA miniature circuit breaker NRN325A 25A 25kA miniature circuit breaker NRN332A 32A 20kA miniature circuit breaker NRN340A 40A 20kA miniature circuit breaker NRN350A 50A 15kA miniature circuit breaker NRN363A 63A 15kA miniature circuit breaker NRN440A Four pole NRN406A 6A 25kA miniature circuit breaker PP NRN410A 10A 25kA miniature circuit breaker NRN416A 16A 25kA miniature circuit breaker NRN420A 20A 25kA miniature circuit breaker NRN425A 25A 25kA miniature circuit breaker NRN432A 32A 20kA miniature circuit breaker NRN440A 40A 20kA miniature circuit breaker NRN450A 50A 15kA miniature circuit breaker NRN463A 63A 15kA miniature circuit breaker KB190C Connection and MCB accessories KB263C KB190C 20mm² 1 pole 1 pole insulated busbar KB263C 10mm² 2 pole 2 pole insulated busbar KB363C KB363C 10mm² 3 pole 3 pole insulated busbar KB380B 16mm² (1 meter) 3 pole 3 pole insulated busbar KB463C 10mm² 4 pole 4 pole insulated busbar KF83B KF83C MZN175 KZ022 end protection caps for busbar KB263C KZ023A end protection caps for busbar KB363C, KB380B KZ024 end protection caps for busbar KB463C KF84A enlarged terminal 25mm² (lateral connection) KF83B enlarged terminal 2 x 25mm² (lateral connection) KF83C enlarged terminal 25mm² (top or lateral connection) MZN130 MZN131 LZ060 dummy module / heat dissipation insert MZN175 padlocking device for toggle of MCB JP024 MCB blanking strip (breakable sections) MZN130 terminal cover / screw cap for HLF, HMC, HMD MZN131 phase seperators for HLF, HMC, HMD (set of 3) B-4

6 MCB auxiliaries / Accessories All auxiliaries are common to both single and multi-pole circuit breakers as well as RCCBs and RCBOs. Auxiliaries are fitted to the left side of the device. Field fittable accessories for MCB s: NF, HMC, NGN, NDN, HMD, HLF, NRN Auxiliary contacts Alarm contacts Shunt trip device Undervoltage release width in 17.5 mm Auxiliaries and tripping devices for MCBs and RCDs MZ201 MZ201 1NO + 1NC 6A 230Vac auxiliary contact block indication of main contact status MZ202 1NO + 1NC 6A 230Vac alarm contact block indicates a fault overcurrent or short circuit MZ Vac shunt trip device permits remote tripping of the device MZ202 MZ Vac / 12-48Vdc shunt trip device permits remote tripping of the device MZ203 MZ Vac under voltage release MCB can only close when voltage above 70% of Un. trips when voltage below 35% of Un. MZ Vac over voltage release trips the protection device in case of overvoltage Add-on earth leakage devices for MCBs For connection to all MCBs to be mounted to the right side of 2, 3, 4 pole circuit breakers. The combined unit provides effective protection against overloads, short circuits as well as earth leakage faults. Features independent indication of earth fault or overload when tripped. BD264 current rating sensitivity poles width in 17.5 mm BD264 63A 30 ma 2 pole earth leakage device BD364 63A 30 ma 3 pole earth leakage device BD464 63A 30 ma 4 pole earth leakage device BF264 63A 300 ma 2 pole earth leakage device BF364 63A 300 ma 3 pole earth leakage device BF464 63A 300 ma 4 pole earth leakage device Add-on earth leakage devices for HLF - HMC - HMD circuit breakers Fixed sensitivity BDC280E 125A 30 ma 2 pole earth leakage device BDC380E 125A 30 ma 3 pole earth leakage device BDC480E 125A 30 ma 4 pole earth leakage device BTC380E Adjustable sensitivity Adjustable trip delay A ms BTC280E 125A 30 ma 2 pole earth leakage device BTC380E 125A 30 ma 3 pole earth leakage device BTC480E 125A 30 ma 4 pole earth leakage device B-5

7 Earth leakage protection CD241J CD464J Residual Current Devices (RCDs) Nuisance tripping Without overload protection Hager earth leakage devices are protected against nuisance tripping Description caused by transient leakage current. To automatically open a circuit in the event of an earth leakage faulty. Field fittable (see page B5) Suitable for domestic, commercial and Auxiliaries and remote operators (CD RCDs only) industrial installations. mechanical life: 40,000 operations Nominal voltage: (2 pole) 110/240V 50Hz specification SABS IEC / SANS (4 pole) 240/415V 50Hz 30mA sensitivity overload sensitivity width in poles rating (A) (ma) 17.5mm CD226J 25A 30 ma 2 pole earth leakage device CD241J 40A 30 ma 2 pole earth leakage device CD264J 63A 30 ma 2 pole earth leakage device CD285Z 100A 30 ma 2 pole earth leakage device CD464J 63A 30 ma 4 pole earth leakage device CD485Z 100A 30 ma 4 pole earth leakage device /300mA sensitivity (selective ) CE264J 63A 100 ma 2 pole earth leakage device CF264J 63A 300 ma 2 pole earth leakage device CF285Z 100A 300 ma 2 pole earth leakage device CF464J 63A 300 ma 4 pole earth leakage device CF485Z 100A 300 ma 4 pole earth leakage device AD890J Combination MCB/RCD (circuit breaker and earth leakage combination) Earth leakage with overload and short circuit protection AD Series 4.5kA C curve 5-10In AD866J 16A 30 ma 2 pole earth leakage + MCB AD870J 20A 30 ma 2 pole earth leakage + MCB AD875J 25A 30 ma 2 pole earth leakage + MCB AD882J 32A 30 ma 2 pole earth leakage + MCB AD890J 40A 30 ma 2 pole earth leakage + MCB Industrial electronic earth leakage relay with separate toroid HR500 HR510 Incorporating test and reset buttons and LED indication Fixed sensitivity, instantaneous trip HR /240V 30 ma 4 pole entry level e/leakage relay HR /240V 300 ma 4 pole entry level e/leakage relay Adjustable sensitivity and trip delay Selectable In threshold: 0.03A/0.1A/0.3A/0.5A/1A/10A (30mA - 10A) Selectable trip delay: 0/0.15/0.35/0.55/1sec/3sec (0-3sec) HR520 HR /240V selectable 4 pole earth leakage relay HR520 as above with fault current indication and 50% pre-alarm output HR700 Above prices do not include VAT. E&OE HR743 Separate torroid sensors HR700 round hole torroid dia 30 mm DIN rail mountable HR742 round hole torroid dia 70 mm standard torroid HR743 round hole torroid dia 105 mm standard torroid HR745 round hole torroid dia 210 mm standard torroid HR830 rectangular hole torroid dia 70 x 175 mm standard torroid B-6

8 Isolators SB series modular isolators (switch disconnectors) For use as a switch disconnector in all s of circuits Green/red indication on handle provides positive contact indication SANS - IEC utilisation category: AC 22B current rating (A) switching poles width in 17.5mm SB132 SB series modular isolators (switch disconnectors) SB232 SBN132 32A on - off 1 pole modular isolator switch SBN163 63A on - off 1 pole modular isolator switch SBN A on - off 1 pole modular isolator switch SBN A on - off 1 pole modular isolator switch SBN232 32A on - off 2 pole modular isolator switch SBN263 63A on - off 2 pole modular isolator switch SBN A on - off 2 pole modular isolator switch SBN A on - off 2 pole modular isolator switch SBN332 32A on - off 3 pole modular isolator switch SBN363 63A on - off 3 pole modular isolator switch SBN A on - off 3 pole modular isolator switch SBN A on - off 3 pole modular isolator switch SBN399 SBN432 32A on - off 4 pole modular isolator switch SBN463 63A on - off 4 pole modular isolator switch SBN A on - off 4 pole modular isolator switch SBN A on - off 4 pole modular isolator switch Changeover switches SFH125 25A on - on 1 pole 2 way changeover switch SFH225 25A on - on 2 pole 2 way changeover switch SFH125 SFT125 25A on-off-on 1 pole centre off changeover switch SFT140 40A on-off-on 1 pole centre off changeover switch SFT240 40A on-off-on 2 pole centre off changeover switch SFT440 40A on-off-on 4 pole centre off changeover switch SF263 63A on-off-on 2 pole centre off changeover switch SF463 63A on-off-on 4 pole centre off changeover switch SFH225 Control transformers (modular DIN rail mount) supply output power width in voltage voltage (VA) 17.5mm ST V 12/24V 25VA modular safety transformer ST V 12/24V 40VA modular safety transformer ST V 12/24V 63VA modular safety transformer ST V 8/12V 8VA modular bell transformer ST V 8/12V 16VA modular bell transformer ST314 Audible devices (modular DIN rail mount) SU V 6.5VA 85 dba modular buzzer SU214 8/12Vac 4.0VA 78 dba modular buzzer SU V 6.5VA 78 dba modular buzzer Fuse holders (modular DIN rail mount) For protection and control of circuits against overloads and short circuits Short-circuit resistance with 10x38 mm fuse link: 80kA SU213 LS501 32A 1 pole modular cylindrical fuse holder LS502 32A 2 pole modular cylindrical fuse holder Control and indicating devices LED indicating lights ( hrs) LS502 SVN... SVN Vac green modular LED indicating light SVN Vac red modular LED indicating light SVN Vac amber modular LED indicating light SVN Vac grn+red modular LED indicating light SVN Vac red/wht/blu modular LED p/light for phase indication SVN Vac/dc green modular LED indicating light SVN Vac/dc red modular LED indicating light SVN351 1no+1nc green modular momentary pushbutton SVN391 1no+1nc grn+red double pushbutton (grn NO / red NC) SVN411 1no green modular pushbutton + green pilot light B-7

9 Modular relays / Contactors ERC216 Modular DIN rail mounting (same cutout as MCBs) One and two module contactors feature economy low consumption, low heat dissipation coils Four ratings: 16A, 25A, 40A, 63A rated power AC-1 AC-3 coil contact width in (A) kw (400V) voltage config 17.5mm Control relays with manual override selector (I-auto-O) ERC216 16A 230Vac modular eco control relay 2NO ERC218 16A 230Vac modular eco control relay 1NO+1NC ERC416 16A 1.7kW 230Vac modular eco control relay 4NO ERC418 16A 1.7kW 230Vac modular eco control relay 2NO+2NC ESC225 ERC418 ESC425 Modular contactors (230 Vac 50/60 Hz) Modular DIN rail mounting ESC225 25A 230Vac modular eco control relay 2NO ESC226 25A 230Vac modular eco control relay 2NC ESC227 25A 230Vac modular eco control relay 1NO+1NC ESC425 25A 2.6kW 230Vac modular eco control relay 4NO ESC427 25A 2.6kW 230Vac modular eco control relay 2NO+2NC ESC240 40A 7.8kW 230Vac modular std contactor 2NO ESC440 40A 7.8kW 230Vac modular std contactor 4NO ESC441 40A 7.8kW 230Vac modular std contactor 4NC ESC442 40A 7.8kW 230Vac modular std contactor 2NO+2NC ESC263 63A 10kW 230Vac modular std contactor 2NO ESC463 63A 10kW 230Vac modular std contactor 4NO ESC464 63A 10kW 230Vac modular std contactor 4NC ESC465 63A 10kW 230Vac modular std contactor 2NO+2NC ESC463 ESC225S ESC425S ESC463S Modular contactors with hum-free coil Low consumption DC coil with integrated rectifier No humming while energised / low switching noise ESC225S 25A 230Vac/dc hum-free eco contactor 2NO ESD225S 25A 24Vac/dc hum-free eco contactor 2NO ESL225S 25A 12Vac/dc hum-free eco contactor 2NO ESC425S 25A 2.6kW 230Vac/dc hum-free eco contactor 4NO ESD425S 25A 2.6kW 24Vac/dc hum-free eco contactor 4NO ESL425S 25A 2.6kW 12Vac/dc hum-free eco contactor 4NO ESC440S 40A 7.8kW 230Vac/dc hum-free contactor 4NO ESD440S 40A 7.8kW 24Vac/dc hum-free contactor 4NO ESL440S 40A 7.8kW 12Vac/dc hum-free contactor 4NO ESC463S 63A 10kW 230Vac/dc hum-free contactor 4NO ESD463S 63A 10kW 24Vac/dc hum-free contactor 4NO ESL463S 63A 10kW 12Vac/dc hum-free contactor 4NO Does not accept clip-on auxiliary Auxiliary contact for all above relays/contactors (except ) ESC080 Ith 6A clip-on auxiliary contact 1NO+1NC Modular stepping relays (pulse ON - pulse OFF ) EPN515 16A 230Vac modular stepping relay 1NO+1NC EPN518 16A 24Vac/12Vdc modular stepping relay 1NO+1NC EPN519 16A 12Vac modular stepping relay 1NO+1NC ESC080 EPN051 EPN053 Auxiliary for all above stepping relays EPN051 Ith 6A clip-on auxiliary contact 1NO+1NC EPN053 Ith 6A impulse converter for maintained contact 1 changeover Above prices do not include VAT. E&OE B-8

10 Modular time switches time range min. contact width in reserve setting config 17.5mm EH010 EH211 Time switches 16A 250V electro-mechanical 230Vac 50Hz AC1 Slimline 1 module wide (18 mm) EH hr 15 min no 1 NO time switch EH hr 15 min 200 hrs 1 NO time switch Standard 2/3 module wide (36 mm) (clock hand indicates time) EH hr 30 min no 1 c/over time switch EH hr 30 min 200 hrs 1 c/over time switch EH hr 15 min no 1 c/over time switch EH hr 15 min 200 hrs 1 c/over time switch EH171 7 day 2 hr 200 hrs 1 c/over time switch Dual dial (1 dial 7 day / 1 dial 24hr) EH111 EH191 7 day / 24 hr 15 min / 2 hr 200 hrs 1 c/over time switch Digital time switches (programmable via buttons or via PC programmable key) Indicates date and time (pre-programmed at factory) Visualisation of daily profile via incorporated bar-graph display Programmable via front keypad (even without suppy) or program key EG005 Up to 56 program steps EH191 Basic version (programming key to be ordered separately) 230Vac EG103B 7 day 1 min 5 years 1 c/over Exclusive version (supplied with programming key) 230Vac Impulse time switch (suitable for school-bell ringing / lunch-tea break) Programmable pulses of 1 sec - 30 min duration Holiday mode programmable (between two dates) Backlit display (for indication in badly illuminated locations) EG103B EG103E 7 day 1 sec 5 years 1 c/over EG203E 7day +7 day 1 sec 5 years 2 c/over / 24Vac/dc (supplied with programming key) EG103V 7 day 1 sec 5 years 1 c/over Channel yearly time switch (300 program steps) EG103E EG004 EG005 EG403E week 1 min 10 years 2 c/o + 2 NC Accessories EG003U PC interface module and programming software for EG series EG004 locking key (for disabling front keypad) EG005 programming key (for down / up loading of program) EG103/203E EG002 programming key (for down / up loading of program) EG403E Modular electronic timers (10A 230V changeover) EG403E Multi - range: 0.1s-10h Multi-voltage: Vac +-10% 10A 230V changeover output EZN001 on-delay multi-range (modular electronic timer) EZN002 delay-on de-energisation (modular electronic timer) EZN003 interval (modular electronic timer) EZN004 pulse controlled interval (modular electronic timer) EZN006 multi-function on-delay / off-delay / interval / repeat timer EZN006 B-9

11 Surge protection devices (SPD) / kwh meters SPN802 Modular surge protection devices SANS/IEC For the protection of low voltage equipment against transient voltages and current surges from atmospheric origins (lightning) as well as transients produced by switching characteristics such as in switching of distribution networks, transformers, motors, etc. poles Up Class 1 and class 2 combined surge protection device Lightning and surge-voltage protection in one device Iimp Imax width in 10/350 μs 8/20 μs 17.5mm Replaceable plug-in cartridges SPN802 3ph+N 1.5kV 100kA class 1+2 surge protector SPN802R 3ph+N 1.5kV 100kA class 1+2 SPD With remote signalling contact for monitoring Class 2 surge protection (modular plug-in) Suitable for second level protection in distribution panels where 1 protectors are installed or areas not exposed to direct lightning strikes and with no external lightning protection system. Protection for domestic, industrial and commercial buildings Replaceable plug-in cartridges Imax 40kA (8/20μs) SPN240D SPN440R SPN140D 1P 1.5kV 40kA class 2 surge protector SPN140R 1P 1.5kV 40kA class 2 surge protector SPN240D 1ph+N 1.5kV 40kA class 2 surge protector SPN240R 1ph+N 1.5kV 40kA class 2 surge protector SPN440D 3ph+N 1.5kV 40kA class 2 surge protector SPN440R 3ph+N 1.5kV 40kA class 2 surge protector With remote signalling contact for monitoring Imax 15kA (8/20μs) SPN215D 1ph+N 1.5kV 15kA class 2 surge protector SPN415D 3ph+N 1.5kV 15kA class 2 surge protector Replacement cartridges for above surge protection devices SPN040D phase replacement cartridge for protectors SPN240/ SPN015D phase replacement cartridge for protectors SPN215/ SPN040N neutral replacement cartridge for protectors SPN2/ SPN040D Energy meters (kwh meters) (modular DIN rail mounting) backlit LCD display Class 1 according to IEC and EN Impulse output Total counter and partial (resettable) counter LED indication blinks according to consumption (1 pulse = 100wh) Accuracy: 1% current operation Single-phase (kwh meter) 63A (direct reading) Displays consumption of active energy and instantaneous power consumption EC150 63A direct reading single-phase kwh meter EC150 Three-phase (kwh meters) 63/100A (direct reading) Displays consumption of active energy and instantaneous power consumption Protected against phase/neutral inversion Adaptable to three phase with or without neutral, 230V or 400V between lines EC350 63A direct reading three-phase kwh meter EC A direct reading three-phase kwh meter Three phase (kwh meters) up to 6000A (connection via current transformer - CT) EC350 Displays consumption of active energy and reactive energy Displays instantaneous power consumption No polarity for CT connection Adaptable to three phase with or without neutral, 230V or 400V between lines EC A CT operated three-phase kwh meter B-10

12 Moulded case circuit breakers (MCCB) A H3 circuit breakers conform to IEC/EN standards and to all major international standards and performance categories. Suitable for co-ordinated installations in all applications Thermal magnetic and electronic release Calibrated at 50ºC Cascading with MCBs (see cascading chart Annex-11) Fixed Fixed Fixed Standard Standard Type HHA...Z HHB...Z HHD...U HNA...U HNB...U No. of poles Electrical Ratings (IEC ) TM TM TM TM TM Rated uninterrupted current Iu (A) at 50ºC Rated voltage Ue Vac Rated voltage Ue Vdc Rated insulation voltage Ui (Vac) Rated impulse withstand voltage Uimp (kv) Utilization category A A A A A Rated current of release In (A) Performance 220/230Vac (Icu) ka /415Vac (Icu) ka Rated ultimate short-circuit, breaking capacity, (Icu) 50-60Hz 480/525Vac (Icu) ka /690Vac (Icu) ka Vdc (2P) (Icu) ka Service breaking capacity Ics (%Icu) 100% 100% 100% 50% 50% Rated making capacity Icm 400Vac Durability mechanical operations electrical operations Adjustable thermal release fixed 1 x In fixed 1 x In In In In Adjustable magnetic >10 In(No adj.) >10 In(No adj.) 6-12 In >10 In 5-11 In Time delay (Electronic release) Suitability for isolation Thermal magnetic release Electronic release Accessories Auxiliary/shunt trip/under volt. release Motor operator/mechan. interlocks Dimensions frame x160 x250 h400 x160 x250 High (with extended terminals) mm Wide (3 pole) mm Deep (without toggle) mm B-11 Above prices do not include VAT. E&OE

13 Moulded case circuit breakers (MCCB) A Standard Standard Standard Standard Standard High Fault High Fault High Fault High Fault HND...U HND...U HNE...U HNE...U HNF...U HEG...U HED...U HEE...U HEF...U 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 TM LSI LSI LSI LSI TM LSI LSI LSI / / / A A A A A A A A A / % 100% 100% 100% 100% 55% 85% 70% 70% In In In In In In In 0,4-1 In In 6-12 In In In In In x In In In (800A)/2.5-8 In (1000A) In sec sec sec sec sec sec sec h400 h630 h1000 h1000 h1600 h250 h630 h1000 h / / / / / Above prices do not include VAT. E&OE B-12

14 Moulded case circuit breakers (MCCB s) 25kA / 50kA Standards: SANS / IEC clip-in accessories Mechanical test button on facia Auxiliary contacts Integrated padlock facility on toggle Alarm contacts Cascading with MCBs (see chart Annex 11) Shunt trip device Lockable thermal/magnetic settings Undervoltage release Window indicating presence of: auxiliary/alarm contacts, shunt trip, UV release (40 ka version) thermal current rated ka 415V (Icu) poles frame Fixed thermal / magnetic trip 25 ka HHA125Z Fixed: thermal 1 x In / magnetic >10 x In HHA016Z 16A 25kA 3 pole moulded case CB x HHA020Z 20A 25kA 3 pole moulded case CB x HHA025Z 25A 25kA 3 pole moulded case CB x HHA032Z 32A 25kA 3 pole moulded case CB x HHA040Z 40A 25kA 3 pole moulded case CB x HHA050Z 50A 25kA 3 pole moulded case CB x HHA063Z 63A 25kA 3 pole moulded case CB x HHA080Z 80A 25kA 3 pole moulded case CB x HHA100Z 100A 25kA 3 pole moulded case CB x HHA125Z 125A 25kA 3 pole moulded case CB x HHA160Z 160A 25kA 3 pole moulded case CB x HHB200Z 200A 25kA 3 pole moulded case CB x HHB250Z 250A 25kA 3 pole moulded case CB x HNA025U HNB250U TM: adjustable thermal x In / adjustable magnetic 6-12 x In HHD400U A 25kA 3 pole moulded case CB h Adjustable thermal / magnetic trip 40 ka TM: adjustable thermal x In / fixed magnetic >10 x In Three pole HNA025U 16-25A 40kA 3 pole moulded case CB x HNA040U 25-40A 40kA 3 pole moulded case CB x HNA063U 40-63A 40kA 3 pole moulded case CB x HNA100U A 40kA 3 pole moulded case CB x HNA125U A 40kA 3 pole moulded case CB x HNA160U A 40kA 3 pole moulded case CB x HNB250U A 40kA 3 pole moulded case CB x Four pole HNA026U 16-25A 40kA 4 pole moulded case CB x HNA041U 25-40A 40kA 4 pole moulded case CB x HNA064U 40-63A 40kA 4 pole moulded case CB x HNA101U A 40kA 4 pole moulded case CB x HNA126U A 40kA 4 pole moulded case CB x HNA161U A 40kA 4 pole moulded case CB x HNB251U A 40kA 4 pole moulded case CB x Adjustable thermal / magnetic trip 50 ka HND630H TM: adjustable thermal x In / adjustable magnetic 6-12 x In HND400H A 50 ka 3 pole moulded case CB h HND401U A 50 ka 4 pole moulded case CB h Adjustable electronic release (LSI) 50 ka LSI: adjustable thermal x In / fixed magnetic x Ir / time sec HND630H A 50 ka 3 pole moulded case CB h HNE800H A 50 ka 3 pole moulded case CB h HNE970U A 50 ka 3 pole moulded case CB h HNF980U A 50 ka 3 pole moulded case CB h HNF990U A 50 ka 3 pole moulded case CB h HNE970U HND631U A 50 ka 4 pole moulded case CB h HNE801U A 50 ka 4 pole moulded case CB h HNE971U A 50 ka 4 pole moulded case CB h HNF981U A 50 ka 4 pole moulded case CB h HNF991U A 50 ka 4 pole moulded case CB h B-13

15 High fault level circuit breakers 65/70kA HEG063U Standards: SANS / IEC clip-in accessories Mechanical test button on facia Auxiliary contacts Cascading with MCBs (see chart Annex 11) Alarm contacts Lockable thermal/magnetic settings Shunt trip device Undervoltage release thermal current rated ka 415V (Icu) poles frame Adjustable thermal / magnetic trip 65 ka TM: adjustable thermal x In / magnetic x In HEG063U 40-63A 65kA 3 pole moulded case circuit breaker h HEG100U A 65kA 3 pole moulded case circuit breaker h HEG160U A 65kA 3 pole moulded case circuit breaker h HEG250U A 65kA 3 pole moulded case circuit breaker h HED630U Adjustable electronic release (LSI) 70 ka LSI: adjustable thermal x In / fixed magnetic x Ir / time sec HED400U A 70kA 3 pole moulded case circuit breaker h HED630U A 70kA 3 pole moulded case circuit breaker h HEE800U A 70kA 3 pole moulded case circuit breaker h HEE970U A 70kA 3 pole moulded case circuit breaker h HEF980U A 70kA 3 pole moulded case circuit breaker h HEF990U A 70kA 3 pole moulded case circuit breaker h Four pole available on request HEE970U Load break switches (switch disconnectors / isolators) HCA125Z 125A 3 pole load break switch (isolator) x HCA160Z 160A 3 pole load break switch (isolator) x HCB250Z 250A 3 pole load break switch (isolator) x HCD400H 400A 3 pole load break switch (isolator) h HCD630H 630A 3 pole load break switch (isolator) h HCE800U 800A 3 pole load break switch (isolator) h HCE970U 1000A 3 pole load break switch (isolator) h HCF980U 1250A 3 pole load break switch (isolator) h HCF990U 1600A 3 pole load break switch (isolator) h HCF990U HCA126Z 125A 4 pole load break switch (isolator) x HCA161Z 160A 4 pole load break switch (isolator) x HCB251Z 250A 4 pole load break switch (isolator) x HCD401U 400A 4 pole load break switch (isolator) h HCD631U 630A 4 pole load break switch (isolator) h HCE801U 800A 4 pole load break switch (isolator) h HCE971U 1000A 4 pole load break switch (isolator) h HCF981U 1250A 4 pole load break switch (isolator) h HCF991U 1600A 4 pole load break switch (isolator) h Accessories for MCCBs and load break switches Auxiliary contacts 1NO + 1NC HXA021H 1NO + 1NC auxiliary contact 1NO+1NC for circuit breakers x HXC021H 1NO + 1NC auxiliary contact 1NO+1NC for circuit breakers h HXA021H HXA024H 1NO + 1NC alarm contact 1NO+1NC for circuit breakers x HXC024H 1NO + 1NC alarm contact 1NO+1NC for circuit breakers h HXA024H HXC004H HXC024H Shunt trip units (SH) HXA001H 24Vdc (SH) shunt trip device for circuit breakers x HXA003H 110Vac (SH) shunt trip device for circuit breakers x HXA004H 230Vac (SH) shunt trip device for circuit breakers x HXA005H 400Vac (SH) shunt trip device for circuit breakers x HXC001H 24Vdc (SH) shunt trip device for circuit breakers h HXC003H 110Vac (SH) shunt trip device for circuit breakers h HXC004H 230Vac (SH) shunt trip device for circuit breakers h HXC005H 400Vac (SH) shunt trip device for circuit breakers h B-14

16 MCCB accessories voltage frame Undervoltage release (UV) HXA011H 24Vdc (UV) undervoltage release for circuit breakers x HXA013H 110Vac (UV) undervoltage release for circuit breakers x HXA014H 230Vac (UV) undervoltage release for circuit breakers x HXA015H 440Vac (UV) undervoltage release for circuit breakers x HXC011H 24Vdc (UV) undervoltage release for circuit breakers h HXC013H 110Vac (UV) undervoltage release for circuit breakers h HXC014H 230Vac (UV) undervoltage release for circuit breakers h HXC015H 440Vac (UV) undervoltage release for circuit breakers h HXC014H HXE011H 24Vdc (UV) undervoltage release for circuit breakers h HXE013H 110Vac (UV) undervoltage release for circuit breakers h HXE014H 230Vac (UV) undervoltage release for circuit breakers h HXE015H 440Vac (UV) undervoltage release for circuit breakers h Rotary handles (padlockable in off position) HXA030H HXA030H direct mount front mount rotary handle for circuit breakers x HXB030H direct mount front mount rotary handle for circuit breakers x HXC030H direct mount front mount rotary handle for circuit breakers h HXD030H direct mount front mount rotary handle for circuit breakers h400/ HXE030H direct mount front mount rotary handle for circuit breakers h HXF030H direct mount front mount rotary handle for circuit breakers h Rotary handles (vari-depth door interlocking) HXA031H HXA031H vary-depth 200mm door interlocking rotary handle and shaft x HXB031H vary-depth 200mm door interlocking rotary handle and shaft x HXC031H vary-depth door interlocking rotary handle and shaft h HXD031H vary-depth door interlocking rotary handle and shaft h400/ HXE031H vary-depth door interlocking rotary handle and shaft h HXF031H vary-depth door interlocking rotary handle and shaft h Terminals and mounting accessories HYD003H HYA033H DIN rail mounting adaptor x HYB033H DIN rail mounting adaptor x HYA036H (3 x 100mm) Din rail raiser (to align MCBs with MCCBs) HYB001H (set of 3) 150 mm² collar terminals for cables x HYD003H (set of 3) 240 mm² collar terminals for cables h400/ HYA027H HYA014H (3 pole) spreader link extended terminals x HYB011H (3 pole) spreader link extended terminals x HYC011H (3 pole) spreader link extended terminals h HYD014H (3 pole) spreader link extended terminals h400/ HYA027H (3 pole) terminal shrouds x HYB021H (3 pole) extended terminal shrouds x HYC021H (3 pole) extended terminal shrouds h HYD021H (3 pole) extended terminal shrouds h400/ HYE021H (3 pole) extended terminal shrouds h HYE021H HYA019H (3 per set) spare interphase barriers x HYB019H (3 per set) spare interphase barriers x HYC019H (3 per set) spare interphase barriers h Special contained palm cable lugs for MCCBs A12-M6/15 50 mm² M6x15 mm contained palm cable lug (ea) x/h A17/M6/17 70 mm² M6x17 mm contained palm cable lug (ea) x/h A19-M8/19 95 mm² M8x19 mm contained palm cable lug (ea) x/h A24B-M8/ mm² M8x19 mm contained palm cable lug (ea) x/h A30B-M8/ mm² M8x19 mm contained palm cable lug (ea) x/h A37-M12/ mm² M12x31 mm contained palm cable lug (ea) h400/ A48-M12/ mm² M12x31 mm contained palm cable lug (ea) h400/ B-15

17 Air circuit breakers (ACBs) for MCCBs Hager s ACBs conform to IEC/EN standards and to all major international standards and performance categories. Easy terminal conversion horizontal vertical Many built-in safety features Easy inspection and maintenance facilities Type HWG HWN HWS HWP No. of poles 3/4 Frame Rated uninterrupted current at 40ºC A 1000, , 1600, , 2500, , 4000 Rated operational voltage at 50/60Hz Ue V 690 Rated insulation voltage at 50/60Hz Ui V 1000 Rated impulse withstand voltage Uimp kv 12 Utilization category B Compliance EN , IEC , GB Rated ultimate 400/415V - 50/60Hz Icu KA Short circuit 500/550V - 50/60Hz Icu KA Breaking capacity 660/690V - 50/60Hz Icu KA Rated service short circuit breaking capacity Ics (% Icu) 100% 100% 100% 100% Rated short time 0.5 Sec Icw KA Withstand 1.0 Sec Icw KA Capacity 3.0 Sec Icw KA Rated short 400/415V - 50/60Hz Icw KA Circuit making 500/550V - 50/60Hz Icw KA Capacity 660/690V - 50/60Hz Icw KA Opening time Nt ms Closing time ms Current setting Ir = In x... A Overload Time delay Tr at 6 x Ir Sec Current setting Is = In x... A Short-circuit Time delay, Ts OFF ms Time delay, Ts ON 10xIn-I 2 t ms Instantaneous Current setting Ip = In x... A MAX Mechanical life no. of cycles Frequency of operation Mechanical cycles/hour 60 Electrical life no. of cycles Frequency of operation Electrical cycles/hour Pitch I/C - O/G mm 105 Pitch Ph-Ph mm Terminal width mm Dimensions Weight Width 3 pole mm Width 4 pole mm Fixed Depth mm 355 Height mm 430 Width 3 pole mm Width 4 pole mm Drawout Depth mm Height mm pole kg Fixed 4 pole kg pole kg Drawout 4 pole kg B-16

18 Air circuit breakers (ACBs) Air circuit breakers are supplied standard with the following: fixed draw-out Auxiliary contacts (4NO + 4NC) Panel door ingress seal (flange for compartment door) RTC (ready to close) contact for spring loaded indication Cradle of draw-out circuit breaker Operation (racking) crank handle Safety shutters (padlockable top and bottom) Terminal converters horizontal-vertical connection LSI microprocessor protection and control unit (mechanical trip indication) HWS432A3/RTC Current setting Ir + In x A Time delay at 6x Ir s Short circuit Is = In x A Time delay Ts 10 x In - I2t ms Instantaneous trip Ip = In x A max LED indication for: power ON, overload, short-circuit, instantaneous, percentage load LSIG control unit including earth fault protection available on request breaking capacity frame thermal ka rms 415V adjustment Draw-out air circuit breaker Three pole (supplied with cradle) HWG310A3/RTC 50kA 3 pole air circuit breaker (draw-out) A HWG312A3/RTC 50kA 3 pole air circuit breaker (draw-out) A HWN320A3/RTC HWN312A3/RTC 65kA 3 pole air circuit breaker (draw-out) A HWN316A3/RTC 65kA 3 pole air circuit breaker (draw-out) A HWN320A3/RTC 65kA 3 pole air circuit breaker (draw-out) A HWS320A3/RTC 80kA 3 pole air circuit breaker (draw-out) A HWS325A3/RTC 80kA 3 pole air circuit breaker (draw-out) A HWS332A3/RTC 80kA 3 pole air circuit breaker (draw-out) A HWP340A3/RTC 100kA 3 pole air circuit breaker (draw-out) A Draw-out air circuit breaker Four pole (supplied with cradle) HWN416A3/RTC 65kA 4 pole air circuit breaker (draw-out) A HWN420A3/RTC 65kA 4 pole air circuit breaker (draw-out) A HWS425A3/RTC 80kA 4 pole air circuit breaker (draw-out) A HWS432A3/RTC 80kA 4 pole air circuit breaker (draw-out) A HWP440A3/RTC 100kA 4 pole air circuit breaker (draw-out) A Fixed- air circuit breaker Three pole HWS432A3/RTC HWG310C3/RTC 50kA 3 pole air circuit breaker (fixed) A HWG312C3/RTC 50kA 3 pole air circuit breaker (fixed) A HWN312C3/RTC 65kA 3 pole air circuit breaker (fixed) A HWN316C3/RTC 65kA 3 pole air circuit breaker (fixed) A HWN320C3/RTC 65kA 3 pole air circuit breaker (fixed) A HWS320C3/RTC 80kA 3 pole air circuit breaker (fixed) A HWS325C3/RTC 80kA 3 pole air circuit breaker (fixed) A HWS332C3/RTC 80kA 3 pole air circuit breaker (fixed) A HWP340C3/RTC 100kA 3 pole air circuit breaker (fixed) A Fixed- air circuit breaker Four pole HWN416C3/RTC 65kA 4 pole air circuit breaker (fixed) A HWN420C3/RTC 65kA 4 pole air circuit breaker (fixed) A HWN320C3/RTC HWS425C3/RTC 80kA 4 pole air circuit breaker (fixed) A HWS432C3/RTC 80kA 4 pole air circuit breaker (fixed) A HWP440C3/RTC 100kA 4 pole air circuit breaker (fixed) A B-17

19 Air circuit breakers (ACBs) accessories HWX213 voltage Shunt opening release HWX Vac shunt opening release for all air circuit breakers HWX Vac shunt opening release for all air circuit breakers HWX Vdc shunt opening release for all air circuit breakers Shunt closing release HWX Vac shunt closing release for all air circuit breakers HWX Vac shunt closing release for all air circuit breakers HWX Vdc shunt closing release for all air circuit breakers HWX253 Under voltage release HWX Vac undervoltage release for all air circuit breakers HWX Vac undervoltage release for all air circuit breakers HWX Vdc undervoltage release for all air circuit breakers Electric charging device (motor) HWX233 HWX Vac motor for automatic charging of closing spring HWX Vac motor for automatic charging of closing spring HWX Vdc motor for automatic charging of closing spring Protection and control units (LSI supplied standard with ACBs) HWW322 LSI std advanced microprocessor based control and protection unit HWW324 LSIG (as above but with earth fault protection) Mechanical interlocking kits (cable for horizontal or vertical interlocking) Up to three circuit breakers fixed/draw-out/mixed versions can be mechanically interlocked in horizontal or vertical configurations. HWX313 HWY121 mechanical interlock (kit) (for two incommers) HWY122 mechanical interlock (kit) (for three incommers) HWY123 mechanical interlock (kit) (for two incommers and one standby) HWY124 mechanical interlock (kit) (for two incommers and one bus coupler) HWY112 door interlock mechanism for all air circuit breakers HWY211 mechanical operation counter for all air circuit breakers Accessories HWY121 HWY141 OFF button key lock facility (requires CLKB fortress lock and key) HWY131 key locking arrangement (for isolated positions) (requires CLKB fortress lock and key) HWY151 key locking arrangement (for all positions) (requires CLKB fortress lock and key) HWY114 spare door ingress seal for fixed ACB HWY115 spare door ingress seal for draw-out ACB CLKB fortress, barrel lock and key for above locking HWY321 Terminals adaptors (convertible from horizontal to vertical) HWY311 terminal adaptor for frame A (ea) HWY321 terminal adaptor for frame A (ea) HWY324 terminal adaptor for frame A (ea) One adaptor required per ACB terminal two adaptors required per 4000A terminal Neutral current transformer (external) for use with LSIG recharge HWY211 HWW A external neutral CT for air circuit breakers (frame 1) HWW A external neutral CT for air circuit breakers (frame 1) HWW A external neutral CT for air circuit breakers (frame 2) HWW A external neutral CT for air circuit breakers (frame 3) HWW A external neutral CT for air circuit breakers (frame 3) B-18

20 Busbar system / Accessories KM13E KM13N Rail mountable earth/neutral terminals (clips vertically onto rail) KM13N rail mountable neutral terminal (blue) 6x16 + 7x10 mm² KM13E rail mountable earth terminal (green) 6x16 + 7x10 mm² Terminal support (clips into various distribution boards) KN00A universal terminal support Din rail mount (horizontal or vertical) 105 mm Distribution terminals (fully insulated clips onto above support) KN00A Incoming Outgoing mm² screw clamp terminal mm² connect cage clamp terminals (push-in) supply output mm² mm² KN26E KN10E 63A 2 x 25 mm² 8 x 4 mm² insulated earth terminal (green) KN18E 63A 4 x 25 mm² 14 x 4 mm² insulated earth terminal (green) KN26E 63A 6 x 25 mm² 20 x 4 mm² insulated earth terminal (green) KN99E earth insulated bridge piece for above terminals (push-in) KN10N 63A 2 x 25 mm² 8 x 4 mm² insulated neutral terminal (blue) KN18N 63A 4 x 25 mm² 14 x 4 mm² insulated neutral terminal (blue) KN26N 63A 6 x 25 mm² 20 x 4 mm² insulated neutral terminal (blue) KN99... KN99N neutral insulated bridge piece for above terminals (10pcs) KN10P 63A 2 x 25 mm² 8 x 4 mm² insualted phase terminal (brown) KN18P 63A 4 x 25 mm² 14 x 4 mm² insualted phase terminal (brown) KN26P 63A 6 x 25 mm² 20 x 4 mm² insualted phase terminal (brown) KN99P phase insulated bridge piece for above terminals (10 pcs) KN04P KN04N 90A 4 x 25 mm² screw clamp insulated neutral termina (blue) KN07N 90A 7 x 25 mm² screw clamp insulated neutral termina (blue) KN04P 90A 4 x 25 mm² screw clamp insulated phase terminal (brown) KN07P 90A 7 x 25 mm² screw clamp insulated phase terminal (brown) KN07N Single-pole distribution blocks (fully protected) Icc: 36kA Space saving IP20 protection DIN rail or bolt down mounting One main cable input - various cable outputs KJ02C amps incoming outgoing terminals (per phase) mm² Icc terminals ka poles KJ02D 125A 1x35/1x16 mm² pole KJ02C 160A 70 mm² pole KJ02A 250A 95 mm² pole KJ02B 400A 150 mm² pole Multi-pole distribution blocks (3Ph+N distribution bars in modular format) KJ02A KJ01B Modular DIN rail mounting (mounts through modular front cut-out) High fault level IEC incoming outgoing terminals (per phase) mm² Icc amps poles terminals ka KJ01A 100A 35 mm² pole KJ01B 80A 16 mm² pole KJ01C 125A 35 mm² pole KJ01D 160A 50 mm² pole B-19 KJ02E KJ02E 100A 25 mm² 5/4 2/ pole = neutral terminals

21 DIN modular domestic sockets / Safety lockout hasps Permits the mounting of domestic switches and/or sockets into standard DIN distribution boards with same dimensions and cutout as modular MCB s to provide an electrical connection for tools or recording instruments. DIN rail mounting housing/support for domestic switches and sockets Mounts into standard distribution boards with same dimensions and cutout as MCB s Two modular widths: one module (18 mm) and two module (36 mm) DIN rail support for Evolution series no. modules (W) 18 mm DIN rail support for Evolution series switches or sockets (1 module) DIN rail support for Evolution series switches or sockets (2 module) Evolution series switches and sockets for above supports Simply clips into DIN rail mount housing (above) G G 15A 2P+E South African socket for housings (2 module) G 16A 2P+E Italian socket for housings (1 module) G 16A 1 Pole switch for housings (I-O) (1 module) G 16A 2 Pole changeover switch for housings (I-O-II) (1 module) Safety lockout hasps Safety lockout hasps permit multiple padlocks to be used when isolating one energy source. The lockout hasp is placed through the isolating point and closed. Each person carrying out maintenance or service attaches their unique individually keyed padlock through the lockout hasp, thereby ensuring complete safety during maintenance operations. The hasp can only be removed once all padlocks have been removed. Scissor action hasp with Ø 25 mm or 38 mm jaw size Accepts padlocks with a shackle diameter up to 9 mm (up to 6 padlocks can be attached) Manufactured from high tensile steel, electroplated to prevent rust ES-VCH-S number of jaw size colour padlocks accepted Vinyl coated hasp Padlock section vinyl coated (red) for improved grip and visibility ES-VCH-S 25 mm red 6 saftey lockout hasp ES-VCH-P 38 mm red 6 saftey lockout hasp ES-VCH-P Lockout padlocks Maximum security laminated padlocks made for tough lockout situations. Increased durability against cutting, prying and twisting Supplied with two keys per lock ES-PLS-KD padlock long shackle - different keys ES-PLS-KD B-20

22 Earth leakage protection new RESYS M40 earth leakage relays associated with a remote trip breaking device (automatic power breaking), provide the following functions: Protection against indirect contact Limitation of leakage currents They also preventively monitor electrical installations via a (configurable) pre-alarm function or when used as a signalling relay Modular DIN rail mountable (same format as MCB s) 44mm wide 2 relays with configurable function (alarm or pre-alarm at 50% IΔn) Adjustment of IΔn: A Time delay: sec Positive or negative security Tripping accuracy by TRMS measurement (improves immunity to nuisance tripping) LED bargraph provides real-time display of leakage currents current time power setting delay supply IΔn (sec) RESYS M40 A differential relay ~ 30A 0 ~ /230 Vac electronic earth leakage relay ~ 30A 0 ~ Vac electronic earth leakage relay ~ 30A 0 ~ 10 12~125 Vdc electronic earth leakage relay RESYS M40R with automatic reclosing M40R relay recloses the system up to six consecutive times after preselected time intervals. If the fault is still present after the sequence of six reclosing attempts, the relay is locked in alarm mode and a manual intervention will be required. Time delay between two reclosings: sec ~ 30A 0 ~ /230 Vac reclosing earth leakage relay ~ 30A 0 ~ Vac reclosing earth leakage relay new RESYS P40 panel mounting (48x48mm) As per RESYS M40 (above) but in panel mounting version ~ 30A 0 ~ /230 Vac panel mount earth leakage relay Core balance transformers (torroidal transformers) - A Active conductors pass through the aperture of the core balance transformer, providing a differential summation of vector currents, enabling detection of leakage currents aperture dimensions (mm) Ø diameter (H) (W) (D) mm core balance transformer for e/leakages mm core balance transformer for e/leakages mm core balance transformer for e/leakages mm core balance transformer for e/leakages mm core balance transformer for e/leakages Larger aperture sizes available on request Accessories for above mm for directly mounting transformers onto cables mm for directly mounting transformers onto cables mm for directly mounting transformers onto cables mm for directly mounting transformers onto cables DIN-rail clip (for directly mounting core balance transformer onto DIN rail) B-21

23 Load break switches 16A - 160A SIRCO M and MV manually operated switches SIRCO modular multipole switches make and break under load conditions and provide safety isolation for any low voltage circuit, particularly for machine control circuits. Modular DIN rail mounting (fits into standard distribution board 45mm cutout) External front (or side) operating handle and shaft (to be ordered seperately-see below) Severe load duty categories (AC-22 and AC-23) Conformity to standards: IEC/EN / IS / UL / KEMA / RINA AC-22 A AC-23 A No. dimensions (mm) 415V (A) 400V (kw) poles (H) (W) (D) SIRCO M series load break switches A A 7.5kW 3 load break switch A 11.0kW 3 load break switch A 15.0kW 3 load break switch A 18.5kW 3 load break switch A 22.0kW 3 load break switch A 37.0kW 3 load break switch A 55.0kW 3 load break switch SIRCO MV series load break switches 160A Visual double break contacts A 75.0kW 3 load break switch A 75.0kW 4 load break switch Operating handles and shafts for above switches (IP65) External front operated, door interlocking, padlockable in off position (3 padlocks) handle colour for switch S00 black operating handle (external) M A S00 red/yellow operating handle (external) M A S0 black operating handle (external) M 125A S0 black operating handle (external) MV 160A S1 black operating handle (external) MV 160A D 2911 S1 black as above (with metal connection) MV 160A Defeatable interlocking mechanism Extension shafts for switches S000/ extension shaft M 16~125A S000/ extension shaft M 16~125A S extension shaft MV 160A S extension shaft MV 160A shaft guide (permits engaging of misaligned shaft with handle) (all sizes) Direct mount handles (mounts directly onto front of switch) M00 blue 5 direct mount handle M 16~80A M01 blue 5 direct mount handle M 100~125A M0b blue 6 direct mount handle MV 160A Auxiliary contacts for switches NO+1NC side mount auxiliary contact 16~160A NO side mount auxiliary contact 16~160A NO internal mounting auxiliary contact 160A NC internal mounting auxiliary contact 160A Attachable 4th pole module (clips onto side of switch) A 1 pole attachable 4th pole module 16-32A A 1 pole attachable 4th pole module 16-63A A 1 pole attachable 4th pole module 100A A 1 pole attachable 4th pole module 125A Conversion kits (mechanical interlock / parallel attachment) supplied with internal direct mount handle I-O-II changeover mechanism between two switches 16~100A I-O-II changeover mechanism between two switches 125A I-O-II handle for above changeover switches 16~125A I-O 6/8 pole conversion kit between two switches 16~100A I-O 6/8 pole conversion kit between two switches 125A Door mount kit (for direct door or side panel mounting of Sirco M switches) door mounting kit (direct door mounting of switch) 16~100A B-22

24 Load break switches 125A A SIRCO manually operated switches SIRCO switches make and break under load conditions and provide safety isolation for any low voltage circuit, particularly for machine control circuits. External front operating handle and shaft (to be ordered separately - see below) Severe load duty categories (AC-22 and AC-23) Conformity to standards: IEC/EN / IS / UL / KEMA / RINA AC-22 A AC-23 A No. dimensions (mm) 415V (A) 400V (kw) poles (H) (W) (D) 26AC 3025 SIRCO AC series load break switches A SIRCO s double break per pole achieved through its sliding bar contact system offers very high durability and short-circuit withstand. Specifically designed arcing chambers provide the switch with improved breaking performance. Position indicator located on the sliding bar mechanism, ensures visibility in all circumstances. High thermal and dynamic withstand High electrical and mechanical endurance A 63kW 3 load break switch A 80kW 3 load break switch AC A 100kW 3 load break switch AC A 132kW 3 load break switch AC A 160kW 3 load break switch AC A 220kW 3 load break switch AC A 280kW 3 load break switch AC A 450kW 3 load break switch AC A 560kW 3 load break switch AC A 710kW 3 load break switch AC A 710kW 3 load break switch AC A 710kW 3 load break switch A 710kW 3 load break switch A 710kW 3 load break switch pole switches 26AC A 132kW 4 load break switch AC A 220kW 4 load break switch AC A 280kW 4 load break switch AC A 450kW 4 load break switch AC A 710kW 4 load break switch Larger sizes (up to 5000A) available on request - 4 pole available on request Operating handles and shafts for above switches (IP65) External front operated, door interlocking, padlockable in off position (3 padlocks) handle colour for switch Pistol grip handles for SIRCO (IP65) S2 black operating handle (external) A D 2911 S2 black as above (with metal connection) A T grip handles for SIRCO (IP65) S4 black operating handle (external) A D 3911 S4 black as above (with metal connection) A S5 black operating handle (external) A Extension shafts for switches handle length mm for switch S2 200mm 10 extension shaft 125~400A S2 320mm 10 extension shaft 125~400A S2 500mm 10 extension shaft 125~400A S4 200mm 15 extension shaft 630~1600A S4 320mm 15 extension shaft 630~1600A S4 400mm 15 extension shaft 630~1600A S5 320mm 30 extension shaft 2000~3200A shaft guide (permits engaging of misaligned shaft with handle) (all sizes) Direct mount handles (mounts directly onto front of switch) J1 black 10 direct mount handle 200~400A C2 black 15 direct mount handle 630~1600A S5 black 30 direct mount handle 2000~3200A Auxiliary contacts for switches Ch/Over auxiliary contact and support 125~3200A Ch/Over additional auxiliary contact 125~3200A See terminal shrouds and screens overleaf page B-33 B-23

25 Motorised switch / Enclosed isolators ESW3080M Ideal contactor replacement for high current switching applications Reliable, robust AC-23A switching Manual override facility (handle supplied) AC-22A AC-23A dimensions (mm) 400V 400V (H) (W) (D) Motorised load-break switches A 75kW 3 pole motorised load break switch A 132kW 3 pole motorised load break switch A 220kW 3 pole motorised load break switch A 280kW 3 pole motorised load break switch A 450kW 3 pole motorised load break switch A 560kW 3 pole motorised load break switch A 710kW 3 pole motorised load break switch A 710kW 3 pole motorised load break switch A 280kW 4 pole motorised load break switch A 450kW 4 pole motorised load break switch A 560kW 4 pole motorised load break switch A 710kW 4 pole motorised load break switch A 710kW 4 pole motorised load break switch Enclosed isolator switches (manually operated) Sheet metal enclosure (IP65) IP65 sheet metal enclosed 3 pole load-break switches Door interlocking external handle (in ON position) Padlockable handle in OFF position (up to 3 padlocks) Colour: BS/EN06 E53 (electric orange) ESW3004M 40A 18.5kW 3 pole enclosed load break switch ESW3006M 63A 30kW 3 pole enclosed load break switch ESW3012M 125A 63kW 3 pole enclosed load break switch pole can be made up by attaching additional 4th pole (see page B-22) to above switches ESW3016M 160A 80kW 3 pole enclosed load break switch ESW3025M 250A 132kW 3 pole enclosed load break switch ESW3040M 400A 220kW 3 pole enclosed load break switch ESW3063M 630A 280kW 3 pole enclosed load break switch ESW3080M 800A 450kW 3 pole enclosed load break switch ESW3100M 1000A 560kW 3 pole enclosed load break switch ESW3125M 1250A 710kW 3 pole enclosed load break switch ESW4017M 160A 80kW 4 pole enclosed load break switch ESW4026M 250A 132kW 4 pole enclosed load break switch ESW4041M 400A 220kW 4 pole enclosed load break switch ESW4064M 630A 280kW 4 pole enclosed load break switch ESW4080M 800A 450kW 4 pole enclosed load break switch ESW4125M 1250A 710kW 4 pole enclosed load break switch Larger sizes available on request Safety enclosures (IP55) Safety enclosed switches provide emergency stop and safety breaking for any low voltage electric circuit. They break ON and OFF load and provide safety isolation. Zinc galvanised sheet metal enclosure 1.5mm thick, door mounted on chrome plated zamak hinges Polyester powder coated corrosion protection minimum thickness 70μm. Bottom mounted gland plate and 2 internal + 1 external earthing connection Metallic side mounted operating handle (red colour) padlockable in OFF position (3 padlocks) Equipped with a double locking system (door can also be padlocked closed in the OFF position) Visible breaking facility is provided through a triplex window (made of 2 layers 3mm thick safety glass) Mechanical flag indicator (visible through triplex window) for indication of switch position status 2 sets terminated auxiliary contacts NO + NC mounted on the double locking system internally Supplied with 2 hooded pushbuttons on right side of enclosure: green 1 NO / red 2 NC contacts Shrouded upper terminals preventing inadvertent touching of incoming supply terminals Colour: BS/EN06 E53 (electric orange) AC-23A AC-23A dimensions (mm) 400V 525V (H) (W) (D) kW 25kW 80A Sider 3P 1way safety switch kW 55kW 125A Sider 3P 1way safety switch kW 90kW 200A Sider 3P 1way safety switch kW 160kW 400A Sider 3P 1way safety switch kW 270kW 630A Sider 3P 1way safety switch B-24

26 Changeover switches 16A A SIRCO M and SIRCOVER manual changeover switches SIRCO manual multipolar changeover switches provide switching, source inversion and changeover under load for two power circuits, as well as their safety isolation by double breaking per pole. Severe load duty categories (AC-23 and AC-33) Conformity to standards: IEC/EN , IEC , IS , UL, KEMA, RINA External front (or side) operating handle and shaft (to be ordered separately - see below) AC 3063 AC-23 A No. dimensions (mm) 415V (A) poles (H) (W) (D) SIRCO M changeover switches A Modular DIN rail mounting (fits into standard distribution board 45mm cutout) Supplied with internal direct mount handle A 3 pole modular changeover switch A 3 pole modular changeover switch A 3 pole modular changeover switch A 3 pole modular changeover switch A 3 pole modular changeover switch pole available by adding 4th poles (see page B-22) Operating handles and shafts for above changeover switches (IP65) S00 black I-O-II ext. operating handle A S01 black I-O-II ext. operating handle 125A mm extension shaft for switch A mm extension shaft for switch 125A SIRCOVER changeover switches A Position indicator located on the sliding bar mechanism, ensures visibility in all circumstances High thermal and dynamic withstand High electrical and mechanical endurance Severe utilization categories (AC-22 and AC-23) 41AC A 3 pole manual changeover switch AC A 3 pole manual changeover switch AC A 3 pole manual changeover switch AC A 3 pole manual changeover switch AC A 3 pole manual changeover switch AC A 3 pole manual changeover switch AC A 3 pole manual changeover switch AC A 3 pole manual changeover switch AC A 3 pole manual changeover switch AC A 4 pole manual changeover switch AC A 4 pole manual changeover switch AC A 4 pole manual changeover switch AC A 4 pole manual changeover switch AC A 4 pole manual changeover switch AC A 4 pole manual changeover switch AC A 4 pole manual changeover switch AC A 4 pole manual changeover switch External handle (door interlocking padlockable in O position) S2 black I-O-II ext. operating handle A S4 black I-O-II ext. operating handle A mm extension shaft for switch A mm extension shaft for switch A J2 black direct switch mounting handle A C1 black direct switch mounting handle A Bridging bars for changeover switches A pole bridging bar set for switch A pole bridging bar set for switch 250A pole bridging bar set for switch 400A pole bridging bar set for switch 630A pole bridging bar set for switch A pole bridging bar set for switch 1250A pole bridging bar set for switch 1600A pole bridging bar set for switch A pole bridging bar set for switch 250A pole bridging bar set for switch 400A pole bridging bar set for switch 630A pole bridging bar set for switch A pole bridging bar set for switch 1250A pole bridging bar set for switch 1600A B-25

27 Bypass switches 160A A / Enclosed manual changeover switch EC03009P EC03009M SIRCOVER manual Bypass switches 160A A SIRCOVER Bypass are a combination of three interlocked switches enabling the use with 3+6 or 4+8 poles from 160A to 1600A. Severe load duty categories (AC-23 and AC-33) Conformity to standards: IEC/EN , IEC , IS , UL, KEMA, RINA External front operating handle and shaft (to be ordered separately - see below) SIRCOVER bypass switches AC-23 A No. dimensions (mm) 415V (A) poles (H) (W) (D) A A 3 pole manual bypass switch A 3 pole manual bypass switch A 3 pole manual bypass switch A 3 pole manual bypass switch A 3 pole manual bypass switch A 3 pole manual bypass switch A 3 pole manual bypass switch A 3 pole manual bypass switch A 4 pole manual bypass switch A 4 pole manual bypass switch A 4 pole manual bypass switch A 4 pole manual bypass switch A 4 pole manual bypass switch A 4 pole manual bypass switch A 4 pole manual bypass switch A 4 pole manual bypass switch External handle (IP65) (door interlocking padlockable in O position) S2 black I-O-II ext. operating handle A S4 black I-O-II ext. operating handle A black I-O-II ext. operating handle A mm extension shaft for switch A mm extension shaft for switch A mm extension shaft for switch A B3 black direct switch mounting handle A C1 black direct switch mounting handle A C2 black direct switch mounting handle A Enclosed manual changeover switches (IP65) Polycarbonate housing (IP65) distribution board enclosure Supplied with internal direct mount handle EC03002P 25A 3 pole enclosed changeover switch EC03004P 40A 3 pole enclosed changeover switch EC03006P 63A 3 pole enclosed changeover switch EC03009P 100A 3 pole enclosed changeover switch EC03012P 125A 3 pole enclosed changeover switch Sheet metal enclosed (IP65) Supplied with external door interlocking handle padlockable in O position EC03004M 40A 3 pole enclosed changeover switch EC03006M 63A 3 pole enclosed changeover switch EC03009M 100A 3 pole enclosed changeover switch EC03012M 125A 3 pole enclosed changeover switch pole switches are made with add-on 4th poles (see page B-22) EC3013M 125A 3 pole enclosed changeover switch EC3016M 160A 3 pole enclosed changeover switch EC3025M 250A 3 pole enclosed changeover switch EC3040M 400A 3 pole enclosed changeover switch EC3063M 630A 3 pole enclosed changeover switch EC3080M 800A 3 pole enclosed changeover switch EC3125M 1250A 3 pole enclosed changeover switch EC3160M 1600A 3 pole enclosed changeover switch EC4016M 160A 4 pole enclosed changeover switch EC4025M 250A 4 pole enclosed changeover switch EC4040M 400A 4 pole enclosed changeover switch EC4063M 630A 4 pole enclosed changeover switch EC4080M 800A 4 pole enclosed changeover switch EC4125M 1250A 4 pole enclosed changeover switch EC4160M 1600A 4 pole enclosed changeover switch B-26

28 Motorised changeover switches 40A - 160A new ATyS S motorised 4 pole changeover switches Fully integrated cost effective solution to switch between main and an alternative power supply for loads of up tp 125A: <90kVA /3 phase 415Vac. Manual override facility (handle supplied) Fail-safe mechanical interlock Wide-band AC control voltage ± 30% Padlockable in the OFF position Can be configured for impulse or contactor logic Energy efficient power consumption is minimal and only required during transfer Fully independent position auxiliary contacts one for each position ( I / O / II ) AC 32B IEC , GB (transfer switch standards) AC 22A IEC (load break switch standard) AC-31 B 415V (A) poles supply voltage ATyS S motorised changeover switches (H) 144 x (W) 198 x (D) 181 mm 230 Vac power supply A 4 pole 230 Vac motorised changeover switch A 4 pole 230 Vac motorised changeover switch A 4 pole 230 Vac motorised changeover switch A 4 pole 230 Vac motorised changeover switch A 4 pole 230 Vac motorised changeover switch Vdc power supply A 4 pole 12 Vdc motorised changeover switch A 4 pole 12 Vdc motorised changeover switch A 4 pole 12 Vdc motorised changeover switch A 4 pole 12 Vdc motorised changeover switch A 4 pole 12 Vdc motorised changeover switch /48 Vdc power supply A 4 pole 24/48 Vdc motorised changeover switch A 4 pole 24/48 Vdc motorised changeover switch A 4 pole 24/48 Vdc motorised changeover switch A 4 pole 24/48 Vdc motorised changeover switch A 4 pole 24/48 Vdc motorised changeover switch ATyS Sd incorporates a dual control power supply 2 x 230 Vac dual power supply A 4 pole 2x230 Vac motorised changeover switch A 4 pole 2x230 Vac motorised changeover switch A 4 pole 2x230 Vac motorised changeover switch A 4 pole 2x230 Vac motorised changeover switch A 4 pole 2x230 Vac motorised changeover switch Accessories pole power terminal bridging bar set (top or bottom) control voltage tapping kit (from power terminals) top supply side terminal protection shrouds x bottom load side terminal protection shrouds x Vac spare motor for above switches x230 Vac spare motor for above switches Vdc spare motor for above switches /48 Vdc spare motor for above switches ATyS M 3s motorised changeover switches (H) 245 x (W) 2P 235/4P 340 x (D) 74 mm ATyS M single-phase or three-phase modular motorised changeover switches with positive break indication,enable on load changeover switching of two supply sources in automatic or manual mode. Modular format to easily mount into standard distribution boards Provide rapid switching, excellent dynamic withstand and long life Positive break indication, switch position indication with back-up manual operation Auto or manual operation (with incorporated Allen key) padlockable in O position A 2 pole 230 Vac motorised changeover switch A 2 pole 230 Vac motorised changeover switch A 2 pole 230 Vac motorised changeover switch A 2 pole 230 Vac motorised changeover switch A 4 pole 230 Vac motorised changeover switch A 4 pole 230 Vac motorised changeover switch A 4 pole 230 Vac motorised changeover switch A 4 pole 230 Vac motorised changeover switch A 4 pole 230 Vac motorised changeover switch B-27

29 Motorised changeover switches 63A - 160A ATyS M 6s automatic changeover switches The ATyS M 6s switch monitors the supply from mains and from generator, if mains fails, the switch provides an output for generator start and once the generator voltage reaches the correct level, switches over to the generator supply until mains is restored which causes the switch to change to the mains supply providing a generator stop signal. AC-31 B 415V (A) poles ATyS M 6s automatic changeover switches supply voltage Monitoring parameters configured via dip switches and potentiometers Potentiometers for: (H) 245 x (W) 2P 235/4P 340 x (D) 47 mm nominal voltage configuration voltage and frequency threshold configuration operating cycle configuration DIP- switches for: LED indication of: 50 or 60Hz, single or 3-phase delay in O position during I-O transfer cycles network/network or network/genset application supply source availability, automatic mode, fault External command inputs for: 2 pole switches automatic mode inhibition remote test on-load (or priority change) manual change of supply from emergency to main source 1NO output relay fro generator start/stop command 1NO fault relay A 2 pole 230 Vac automatic changeover switch A 2 pole 230 Vac automatic changeover switch A 2 pole 230 Vac automatic changeover switch A 2 pole 230 Vac automatic changeover switch pole switches A 4 pole 230 Vac automatic changeover switch A 4 pole 230 Vac automatic changeover switch A 4 pole 230 Vac automatic changeover switch A 4 pole 230 Vac automatic changeover switch A 4 pole 231 Vac automatic changeover switch ATyS M 6e automatic transfer switches (digital display and settings) Self powered from incoming supply, the digital inbuilt control unit monitors voltage and frequency thresholds and can be programmed to automatically switch form one supply source to another. Monitoring parameters configured via pushbuttons and digital display Network/genset, network/network (with or without priority) Display/keyboard for programming values and visualisation of electrical parameters LED indicator: power on, supply status, position of switch, auto/manual/test mode, fault 3 configurable inputs 3 configurable output relays 1 configurable bi-stable output relay for generator start/stop command 4 pole switches A 4 pole 230 Vac automatic changeover switch A 4 pole 230 Vac automatic changeover switch A 4 pole 230 Vac automatic changeover switch A 4 pole 230 Vac automatic changeover switch A 4 pole 230 Vac automatic changeover switch Accessories for all ATyS M switches Bridging bars (plug-in) (for incoming of outgoing side of switch) Provides a common connection between switches I & II on the incoming or outgoing side of the ATyS M without reducing terminal capacity A 2 pole fully insulated plug-in bridging bar A 4 pole fully insulated plug-in bridging bar A 4 pole fully insulated plug-in bridging bar pole tap-off terminal for power supply pole terminal protection shroud auxiliary contact 1NO + 1NC for each position (I-O-II) B-28

30 Motorised changeover switches 160A A ATyS R motorised changeover switches ATyS R are three-phase motorised changeover switches with positive break indication. They enable the on load transfer of two three-phase supplies via remote volt-free contacts, from either an external automatic controller, using pulse logic, or a switch. new Integrated auxiliary contacts (one contact for each position) Wide-band AC control voltage ± 20% Fail-safe mechanical interlock Padlockable in the OFF position Fully independent position auxiliary contacts one for each position ( I / O / II ) AC-31 B dimensions (mm) poles 415V (A) (H) (W) (D) ATyS R motorised changeover switches supply: 230Vac (previously ATyS 3s) 3 pole switches A 3 pole motorised changeover switch A 3 pole motorised changeover switch A 3 pole motorised changeover switch A 3 pole motorised changeover switch A 3 pole motorised changeover switch A 3 pole motorised changeover switch A 3 pole motorised changeover switch A 3 pole motorised changeover switch pole switches A 4 pole motorised changeover switch A 4 pole motorised changeover switch A 4 pole motorised changeover switch A 4 pole motorised changeover switch A 4 pole motorised changeover switch A 4 pole motorised changeover switch A 4 pole motorised changeover switch A 4 pole motorised changeover switch Larger sizes (up to 3200A) available on request ATyS G automatic changeover switches supply: 230Vac (previously ATyS 3e + 6e) ATyS G products are automatic changeover switches intended specifically for transformer/generator applications. The integrated controller provides all functions necessary for these applications, including monitoring the voltage and frequency of both sources, and on load changeover switching between two power supply sources, configured via four potentiometers and four DIP switches. Integrated dual power supply (2 independent supplies within the switch) Integrated generator on-load and off-load test function Fail-safe mechanical interlock Padlockable in the OFF position Fully independent position auxiliary contacts one for each position ( I / O / II ) ATyS G Automatic changeover switches (for standby generators) 3 pole switches A 3 pole motorised changeover switch A 3 pole motorised changeover switch A 3 pole motorised changeover switch A 3 pole motorised changeover switch A 3 pole motorised changeover switch A 3 pole motorised changeover switch A 3 pole motorised changeover switch A 3 pole motorised changeover switch pole switches A 4 pole motorised changeover switch A 4 pole motorised changeover switch A 4 pole motorised changeover switch A 4 pole motorised changeover switch A 4 pole motorised changeover switch A 4 pole motorised changeover switch A 4 pole motorised changeover switch A 4 pole motorised changeover switch Larger sizes (up to 3200A) available on request B-29

31 Motorised changeover switch 250A-3200A / Accessories for changeover switches new ATyS P automatic changeover switches (digital display) ATyS P products are automatic changeover switches intended specifically for power management applications enabling effective monitoring of installations thanks to time-stamped event recording. Events can be retrieved and read via the communication system. Particularly suited to energy and monitoring. Optional communication modules RS-485 or Ethernet Recording of events Possibilty to set periodic genset startup Power measurements Programmable inputs/outputs can be utilised to control load shedding based on load level or tariff current poles dimensions (mm) (H) (W) (D) ATyS P automatic changeover switches (previously ATyS 6m) 3 pole switches A 3 pole motorised ch/over switch A 3 pole motorised ch/over switch A 3 pole motorised ch/over switch A 3 pole motorised ch/over switch A 3 pole motorised ch/over switch A 3 pole motorised ch/over switch pole switches A 4 pole motorised ch/over switch A 4 pole motorised ch/over switch A 4 pole motorised ch/over switch A 4 pole motorised ch/over switch A 4 pole motorised ch/over switch A 4 pole motorised ch/over switch Larger sizes (up to 3200A) available on request Accessories for ATyS switches poles for switch pole terminal protection shroud 160A pole terminal protection shroud 250/400A pole terminal protection shroud 630A pole terminal protection shroud 250/400A pole terminal protection shroud 630A pole bridging bar for ch/over switches 160A pole bridging bar for ch/over switches 250A pole bridging bar for ch/over switches 400A pole bridging bar for ch/over switches 630A pole bridging bar for ch/over switches 800/1000A pole bridging bar for ch/over switches 1250A pole bridging bar for ch/over switches 1600A pole voltage sense and p/supply harness 160A pole voltage sense and p/supply harness 250A pole voltage sense and p/supply harness 400A pole voltage sense and p/supply harness 630A pole voltage sense and p/supply harness 800/1000A pole voltage sense and p/supply harness 1250A pole voltage sense and p/supply harness 1600A N-right 4 pole voltage sense and p/supply harness 200/250A N-right 4 pole voltage sense and p/supply harness 200/250A N-right 4 pole voltage sense and p/supply harness 400A N-right 4 pole voltage sense and p/supply harness 630A N-right 4 pole voltage sense and p/supply harness 800/1000A N-right 4 pole voltage sense and p/supply harness 1250A N-right 4 pole voltage sense and p/supply harness 1600A plug-in RS485 MODBUS communication module all ATyS P plug-in plug-in 2 input and 2 output module all ATyS P plug-in Ethernet communication module all ATyS P plug-in Ethernet communication + RS485 JBUS/MODBUS all ATyS P remote control interface (panel mount) all ATyS P remote control interface with display (panel mount) all ATyS P connecting cable for (above) remote interfaces all ATyS P mounting spacers (stackable) raises switch by 10mm (2 per set) /4 pole door protective frame for switches ATyS R A /4 pole door protective frame for switches ATyS R A /4 pole door protective frame for switches ATySg/p A /4 pole door protective frame for switches ATySg/p A Vdc-230Vac p/supply to operate switches with DC all ATyS R/G/P dual power supply permits remote transfer to any position all ATyS R B-30

32 Enclosed automatic changeover panels 63A A Enclosed automatic changeover panels ATyS automatic changeover panel is a complete AMS (automatic mains failure) switch in an enclosure. The internal ATyS G switch features an integrated controller which monitors the voltage and frequency of both the mains and generator supply. Should the monitored conditions move beyond the pre-configured parameters, the switch provides a generator start signal and once the generator voltage and frequency reach within the preset limits, the switch changes over to the generator supply, when mains are restored the switch changes back to the mains supply and provides a generator stop signal. Easy parameter setup via four potentiometers and DIP switches Integrated dual power supply (2 independent supplies within the switch) Integrated generator on-load and off-load test function Fail-safe mechanical interlock Supplied complete with bridge bars on output side manual override key/handle AC-31 B supply dimensions (mm) poles 415V (A) voltage (H) (W) (D) ATyS M automatic changeover systems 2 pole switches A EAC2004M 40A 230 Vac 2 pole automatic ch/over panel EAC2006M 63A 230 Vac 2 pole automatic ch/over panel EAC2008M 80A 230 Vac 2 pole automatic ch/over panel EAC2010M 100A 230 Vac 2 pole automatic ch/over panel pole switches EAC4004M 63A 230 Vac 4 pole automatic ch/over panel EAC4006M 80A 230 Vac 4 pole automatic ch/over panel EAC4015M 100A 230 Vac 4 pole automatic ch/over panel EAC4012M 125A 230 Vac 4 pole automatic ch/over panel EAC4016M 160A 231 Vac 4 pole automatic ch/over panel ATyS G automatic changeover systems 3 pole switches A EAC3025M 250A 230 Vac 3 pole automatic ch/over panel EAC3040M 400A 230 Vac 3 pole automatic ch/over panel EAC3063M 630A 230 Vac 3 pole automatic ch/over panel EAC3080M 800A 230 Vac 3 pole automatic ch/over panel EAC3100M 1000A 230 Vac 3 pole automatic ch/over panel EAC3125M 1250A 230 Vac 3 pole automatic ch/over panel EAC3160M 1600A 230 Vac 3 pole automatic ch/over panel pole switches EAC4025M 250A 230 Vac 4 pole automatic ch/over panel EAC4040M 400A 230 Vac 4 pole automatic ch/over panel EAC4063M 630A 230 Vac 4 pole automatic ch/over panel EAC4080M 800A 230 Vac 4 pole automatic ch/over panel EAC4100M 1000A 230 Vac 4 pole automatic ch/over panel EAC4125M 1250A 230 Vac 4 pole automatic ch/over panel EAC4160M 1600A 230 Vac 4 pole automatic ch/over panel Larger sizes (up to 3200A) available on request B-31

33 Switch fuses 32A A FUSERBLOC Fuse combination switches FUSERBLOC are manually operated multipole fuse combination switches. They make and break on load and provide safety isolation and protection against overcurrent in any low voltage electrical circuit. Complete isolation of fuses with double breaking per pole (top and bottom of fuse) Positive break indication Test position for testing control circuits without power (enclosure door can be opened in test position) External front operating handle and shaft (to be ordered seperately-see below) IEC/EN , IEC/EN , IEC/EN , VDE , VDE AC-22 A AC-23 A fuse dimensions (mm) 415V (A) 400V (kw) (H) (W) (D) NFC Cylindrical fuses (3 pole) CD32A 15kW 10x38 fuse combination switch A 25kW 14x51 fuse combination switch A 63kW 22x58 fuse combination switch DIN pattern fuses A 30kW 00C fuse combination switch A 63kW 00C fuse combination switch A 80kW 00 fuse combination switch A 132kW 1 fuse combination switch A 220kW 2 fuse combination switch A 355kW 3 fuse combination switch A 450kW 3 fuse combination switch A 560kW 4 fuse combination switch BS88 pattern fuses CD32A 15kW A1 fuse combination switch A 15kW A1 fuse combination switch A 30kW A2-A3 fuse combination switch A 51kW A4 fuse combination switch A 80kW A4 fuse combination switch A 100kW B1-B2 fuse combination switch A 132kW B1-B2-B3 fuse combination switch A 160kW B1-B2-B3 fuse combination switch A 220kW B2-B3-B4 fuse combination switch A 355kW C1-C2 fuse combination switch A 450kW C1-C2-C3 fuse combination switch A 560kW D1 fuse combination switch Operating handles and shafts for above switches (IP65) External front operated, door interlocking, padlockable (3 padlocks) in off with test position handle colour for switch S1 black pistol grip operating handle (external) 32-63A S2 black pistol grip operating handle (external) A S2 black pistol grip operating handle (external) A S4 black pistol grip operating handle (external) 1250A Extension shafts for above switches handle length mm² for switch S1 320mm 5 extension shaft for switch CD32A S1 400mm 5 extension shaft for switch CD32A S2 200mm 10 extension shaft for switch A S3 320mm 10 extension shaft for switch A S4 500mm 10 extension shaft for switch A S3 320mm 12 extension shaft for switch 630~1250A S3 500mm 12 extension shaft for switch 630~1250A shaft guide (permits engaging of misaligned shaft with handle) (all sizes) Auxiliary contacts for switch fuses NO auxiliary contact and support CD A NC additional auxiliary contact CD A contact holder for additional auxiliary contacts CD32A contact holder for additional auxiliary contacts A B-32

34 Terminal shrouds for switches Top and/or bottom protection against direct contact with the terminals or connection parts. Made of translucent material for ease of inspection without having to remove first. Shrouds also provide phase separation. poles for switches Terminal shrouds for SIRCO M/MV switches (top or bottom terminal protection) pole terminal protection shroud for switches Sirco M 16-63A pole terminal protection shroud for switches Sirco M 16-63A pole terminal protection shroud for switches Sirco M 100A pole terminal protection shroud for switches Sirco M 100A pole terminal protection shroud for switches Sirco M/MV A pole terminal protection shroud for switches Sirco M/MV A Terminal shrouds for SIRCO AC switches Also provides phase separation for switches (top or bottom terminal protection) pole terminal protection shroud for switches Sirco A pole terminal protection shroud for switches Sirco A pole terminal protection shroud for switches Sirco A Inter-phase barriers (essential for use at 690V or in polluted or dusty atmosphere) pole inter-phase barriers for switches Sirco A pole inter-phase barriers for switches Sirco A pole inter-phase barriers for switches Sirco A Terminal screens pole terminal protection screens for switches Sirco A pole terminal protection screens for switches Sirco A pole terminal protection screens for switches Sirco A Terminal shrouds for FUSERBLOC fuse switches (top and/or bottom terminal protection) Also provides phase separation for switches pole terminal protection shroud for switches Fuserbloc A pole terminal protection shroud for switches Fuserbloc A pole terminal protection shroud for switches Fuserbloc A pole terminal protection shroud for switches Fuserbloc 1250A B-33

35 Industrial cylindrical fuse-links Cylindrical fuse links made of ceramic tube with high withstand to internal pressure and thermal shock, permitting very high breaking capacities in a compact fuse design. Melting elements are specially designed to avoid ageing thus maintaining their electrical characteristics over time. Standards: IEC/EN , IEC/EN rated rated breaking dimensions current voltage capacity (mm) gg cylindrical fuse links gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. 10 x 38mm cylindrical fuses A 500V 120kA 10 x 38 gg cylindrical fuse link A 500V 120kA 10 x 38 gg cylindrical fuse link A 500V 120kA 10 x 38 gg cylindrical fuse link A 500V 120kA 10 x 38 gg cylindrical fuse link A 500V 120kA 10 x 38 gg cylindrical fuse link A 500V 120kA 10 x 38 gg cylindrical fuse link A 500V 120kA 10 x 38 gg cylindrical fuse link A 500V 120kA 10 x 38 gg cylindrical fuse link A 500V 120kA 10 x 38 gg cylindrical fuse link A 400V 120kA 10 x 38 gg cylindrical fuse link x 51mm cylindrical fuses A 690V 80kA 14 x 51 gg cylindrical fuse link A 690V 80kA 14 x 51 gg cylindrical fuse link A 690V 80kA 14 x 51 gg cylindrical fuse link A 690V 80kA 14 x 51 gg cylindrical fuse link A 500V 120kA 14 x 51 gg cylindrical fuse link A 500V 120kA 14 x 51 gg cylindrical fuse link A 400V 120kA 14 x 51 gg cylindrical fuse link x 58mm cylindrical fuses A 690V 80kA 22 x 58 gg cylindrical fuse link A 690V 80kA 22 x 58 gg cylindrical fuse link A 690V 80kA 22 x 58 gg cylindrical fuse link A 690V 80kA 22 x 58 gg cylindrical fuse link A 500V 120kA 22 x 58 gg cylindrical fuse link A 500V 120kA 22 x 58 gg cylindrical fuse link A 400V 120kA 22 x 58 gg cylindrical fuse link gg class cylindrical fuse links with striker For use with holder incorporating a micro switch to provide remote indication of blown fuse 14 x 51mm cylindrical fuses A 500V 120kA 14 x 51 gg fuse link with striker A 500V 120kA 14 x 51 gg fuse link with striker A 500V 120kA 14 x 51 gg fuse link with striker A 500V 120kA 14 x 51 gg fuse link with striker A 500V 120kA 14 x 51 gg fuse link with striker A 500V 120kA 14 x 51 gg fuse link with striker A 500V 120kA 14 x 51 gg fuse link with striker A 500V 120kA 14 x 51 gg fuse link with striker A 400V 120kA 14 x 51 gg fuse link with striker x 58mm cylindrical fuses A 690V 80kA 22 x 58 gg fuse link with striker A 690V 80kA 22 x 58 gg fuse link with striker A 690V 80kA 22 x 58 gg fuse link with striker A 690V 80kA 22 x 58 gg fuse link with striker A 500V 120kA 22 x 58 gg fuse link with striker A 500V 120kA 22 x 58 gg fuse link with striker A 400V 120kA 22 x 58 gg fuse link with striker Solid neutral links A 10 x 38 gg/am solid neutral link A 14 x 51 gg/am solid neutral link A 22 x 58 gg/am solid neutral link B-34

36 Industrial cylindrical fuse-links am fuse links for short circuit protection of motors, transformers and other loads with high inrush currents. Excellent protection of switchgear due to the effective current limiting capabilities and low I²t values. Standards: IEC/EN , IEC/EN rated rated breaking dimensions current voltage capacity (mm) am (motor protection) fuse links x 38mm cylindrical fuses A 500V 120kA 10 x 38 am cylindrical fuse link A 500V 120kA 10 x 38 am cylindrical fuse link A 500V 120kA 10 x 38 am cylindrical fuse link A 500V 120kA 10 x 38 am cylindrical fuse link A 500V 120kA 10 x 38 am cylindrical fuse link A 500V 120kA 10 x 38 am cylindrical fuse link A 500V 120kA 10 x 38 am cylindrical fuse link A 400V 120kA 10 x 38 am cylindrical fuse link A 400V 120kA 10 x 38 am cylindrical fuse link x 51mm cylindrical fuses A 690V 80kA 14 x 51 am cylindrical fuse link A 690V 80kA 14 x 51 am cylindrical fuse link A 500V 120kA 14 x 51 am cylindrical fuse link A 500V 120kA 14 x 51 am cylindrical fuse link A 400V 120kA 14 x 51 am cylindrical fuse link x 58mm cylindrical fuses A 690V 80kA 22 x 58 am cylindrical fuse link A 690V 80kA 22 x 58 am cylindrical fuse link A 690V 80kA 22 x 58 am cylindrical fuse link A 690V 80kA 22 x 58 am cylindrical fuse link A 500V 120kA 22 x 58 am cylindrical fuse link A 500V 120kA 22 x 58 am cylindrical fuse link A 400V 120kA 22 x 58 am cylindrical fuse link gr RAPIDPLUS high speed fuse links for semiconductors gr cylindrical high speed fuse-links provide optimum protection of semiconductor devices (thyristors, triacs, diodes, rectifiers, static relays, etc.) provides protection of overloads and short circuits. Melting elements are specially designed to obtain low I²t values and reduce arc voltages to provide adequate selective coordination with upstream fuse links. Typical applications include protection of rectifiers, UPS, motor drives, soft starters and inverters. Standards: IEC/EN , IEC/EN A 690V 100kA 10 x 38 gr semiconductor fuse link A 690V 100kA 10 x 38 gr semiconductor fuse link A 690V 100kA 10 x 38 gr semiconductor fuse link A 690V 100kA 10 x 38 gr semiconductor fuse link A 690V 100kA 10 x 38 gr semiconductor fuse link A 690V 100kA 10 x 38 gr semiconductor fuse link A 690V 100kA 10 x 38 gr semiconductor fuse link A 690V 100kA 14 x 51 gr semiconductor fuse link A 690V 100kA 14 x 51 gr semiconductor fuse link A 690V 100kA 14 x 51 gr semiconductor fuse link A 690V 100kA 22 x 58 gr semiconductor fuse link A 690V 100kA 22 x 58 gr semiconductor fuse link A 690V 100kA 22 x 58 gr semiconductor fuse link A 690V 100kA 22 x 58 gr semiconductor fuse link gr high speed fuse links for semiconductors with striker A 690V 100kA 14 x 51 gr semiconductor fuse link A 690V 100kA 14 x 51 gr semiconductor fuse link A 690V 100kA 14 x 51 gr semiconductor fuse link A 690V 100kA 14 x 51 gr semiconductor fuse link A 690V 100kA 14 x 51 gr semiconductor fuse link A 690V 100kA 14 x 51 gr semiconductor fuse link A 690V 100kA 14 x 51 gr semiconductor fuse link A 690V 100kA 22 x 58 gr semiconductor fuse link A 690V 100kA 22 x 58 gr semiconductor fuse link A 690V 100kA 22 x 58 gr semiconductor fuse link A 690V 100kA 22 x 58 gr semiconductor fuse link B-35

37 Industrial modular cylindrical fuse holders new new PMX series modular fuseholders Modular, compact fuse holder DIN rail mountable for cylindrical fuses Incorporated, hinged transparent label holder for positive circuit identification Optimized ventilation zones for improved heat dissipation High temperature resistance, self-extinguishing-halogen free body / silver plated copper contacts Standards: IEC/EN , IEC/EN , IEC/EN , CSA C , UL For 10 x 38mm fuse-links rated for fuse width in poles current size 17.5 (mm) (H) 88.8 x (W) 17.5 x (D) 58 mm A 10 x 38 1 pole 1 industrial cylindrical fuseholder A 10 x 38 1 pole+n 2 industrial cylindrical fuseholder A 10 x 38 2 pole 2 industrial cylindrical fuseholder A 10 x 38 3 pole 3 industrial cylindrical fuseholder A 10 x 38 4 pole 4 industrial cylindrical fuseholder With indicator A 10 x 38 1 pole 1 with 120~690V neon indication Accessories for 10x38mm fuse holder body pincers for multi-pole assembly of 10x38mm fuse holders handle pin for multi-pole assembly of 10x38mm fuse holders lock support for padlocking holder 10x38mm fuse holders phase separator accessory 10x38mm fuse holders replacement fusing neon indicator 120~690V 10x38mm fuse holders For 14 x 51mm fuse-links (H) 110 x (W) 26.5 x (D) 76 mm A 14 x 51 1 pole 1.5 industrial cylindrical fuseholder A 14 x 51 1 pole+n 3 industrial cylindrical fuseholder A 14 x 51 3 pole 4.5 industrial cylindrical fuseholder With indicator (replaceable indicator module) A 14 x 51 1 pole 1.5 with 120~690V neon indication Accessories for 14x51mm fuse holder body pincers for multi-pole assembly of 14x51mm fuse holders handle pin for multi-pole assembly of 14x51mm fuse holders micro switch ties for multiple assembly for 14x51mm fuse holders lock support for padlocking holder 14x51mm fuse holders micro switch 1 pole for use with fuses with striker micro switch 3 pole for use with fuses with striker micro switch unipolar extension 14x51mm fuse holders replacement fusing neon indicator 120~690V 14x51mm fuse holders For 22 x 58mm fuse-links (H) x (W) 35.5 x (D) 76.5 mm A 22 x 58 1 pole 2 industrial cylindrical fuseholder A 22 x 58 1 pole+n 4 industrial cylindrical fuseholder A 22 x 58 3 pole 6 industrial cylindrical fuseholder With indicator (indicator module replaceable) A 22 x 58 1 pole 2 with 120~690V neon indication Although all our 22 x 58 cylindrical fuse links are rated at 125A, they are marked at 100A in order to conform to IEC/EN requirements Accessories for 22 x 58mm fuse holder body pincers for multi-pole assembly of 22x58mm fuse holders handle pin for multi-pole assembly of 22x58mm fuse holders micro switch ties for multiple assembly of 22x58mm fuse holders padlocking facility accessory 22x58mm fuse holders micro switch 1 pole for use with fuses with striker micro switch 3 pole for use with fuses with striker micros switch unipolar extension 22x58mm fuse holders replacement fusing neon indicator 120~690V 22x58mm fuse holders PMC series compact modular fuseholders low profile (38.5mm) Compact fuse holders with very shallow dimension suitable for installation into low profile enclosures. For 10 x 38mm fuse-links (H) 82.7 x (W) 17.8 x (D) 38.5 mm A 10 x 38 1 pole 1 compact cylindrical fuseholder A 10 x 38 1 pole+n 1 compact cylindrical fuseholder Accessories for compact 10x38mm fuse holder body pincers for multi-pole assembly of 10x38mm PMC fuse holders handle pin for multi-pole assembly of 10x38mm PMC fuse holders 3.00 Above prices do not include VAT. E&OE B-36

38 NH industrial HRC fuses Knife (NH) fuse-links gg class for general use. High breaking capacity intended for protection of power lines and equipment against overloads and short-circuits. Ceramic body with high withstand to internal pressure and thermal shock, offering high breaking capacity. Manufactured according to IEC/EN60269 and VDE0636 Standards and comply with RoHS directive. Standards: IEC/EN , IEC/EN , DIN rated rated breaking fuse current voltage capacity size NH000 gg NH HRC fuse links 500V top indicator NH00 gg class for use as general protection against overloads and short circuits For protection of cables, power lines and equipment Fusing indicator on top of fuse link A 500V 120kA NH000 gg DIN HRC fuse link A 500V 120kA NH000 gg DIN HRC fuse link A 500V 120kA NH000 gg DIN HRC fuse link A 500V 120kA NH000 gg DIN HRC fuse link A 500V 120kA NH000 gg DIN HRC fuse link A 500V 120kA NH000 gg DIN HRC fuse link A 500V 120kA NH000 gg DIN HRC fuse link A 500V 120kA NH000 gg DIN HRC fuse link A 500V 120kA NH000 gg DIN HRC fuse link A 500V 120kA NH000 gg DIN HRC fuse link A 500V 120kA NH000 gg DIN HRC fuse link A 500V 120kA NH00 gg DIN HRC fuse link A 500V 120kA NH00 gg DIN HRC fuse link NH A 500V 120kA C1 gg DIN HRC fuse link A 500V 120kA NH1 gg DIN HRC fuse link A 500V 120kA NH1 gg DIN HRC fuse link A 500V 120kA NH1 gg DIN HRC fuse link A 500V 120kA NH1 gg DIN HRC fuse link A 500V 120kA NH2 gg DIN HRC fuse link A 500V 120kA NH2 gg DIN HRC fuse link A 500V 120kA NH2 gg DIN HRC fuse link A 500V 120kA NH2 gg DIN HRC fuse link A 500V 120kA NH3 gg DIN HRC fuse link A 500V 120kA NH3 gg DIN HRC fuse link A 500V 120kA NH3 gg DIN HRC fuse link A 500V 120kA NH4 gg DIN HRC fuse link A 500V 120kA NH4 gg DIN HRC fuse link A 500V 120kA NH4 gg DIN HRC fuse link NH2 gg NH HRC fuse links 690V top indicator A 690V 80kA NH000 gg DIN HRC fuse link A 690V 80kA NH000 gg DIN HRC fuse link A 690V 80kA NH000 gg DIN HRC fuse link A 690V 80kA NH000 gg DIN HRC fuse link A 690V 80kA NH000 gg DIN HRC fuse link A 690V 80kA NH000 gg DIN HRC fuse link A 690V 80kA NH000 gg DIN HRC fuse link A 690V 80kA NH00 gg DIN HRC fuse link A 690V 80kA NH00 gg DIN HRC fuse link A 690V 80kA NH00 gg DIN HRC fuse link A 690V 80kA NH00 gg DIN HRC fuse link A 690V 80kA NH1 gg DIN HRC fuse link A 690V 80kA NH1 gg DIN HRC fuse link A 690V 80kA NH1 gg DIN HRC fuse link A 690V 80kA NH2 gg DIN HRC fuse link A 690V 80kA NH2 gg DIN HRC fuse link A 690V 80kA NH3 gg DIN HRC fuse link A 690V 80kA NH3 gg DIN HRC fuse link A 690V 80kA NH3 gg DIN HRC fuse link NH A 690V 80kA NH4 gg DIN HRC fuse link A 690V 80kA NH4 gg DIN HRC fuse link Fuse bases for above (see page B-39) B-37

39 NH industrial HRC fuses new am (motor protection) fuse links am class (NH) for motor protection. These high breaking capacity fuse-links are intended for short circuit protection in motors, transformers and other loads with high inrush currents, with rated voltages up to 500Vac (120kA) and 690Vac (80kA). They offer excellent protection of switchgear (contactor, thermal overloads) due to the good current limiting capability and low I²t values. Standards: IEC/EN , IEC/EN and VDE43620 rated rated breaking fuse current voltage capacity size am NH (motor protection) fuse links 500/690V top indicator A 690V 80kA NH000 am HRC DIN fuse link A 690V 80kA NH000 am HRC DIN fuse link A 690V 80kA NH000 am HRC DIN fuse link A 690V 80kA NH000 am HRC DIN fuse link A 690V 80kA NH000 am HRC DIN fuse link A 690V 80kA NH000 am HRC DIN fuse link A 690V 80kA NH000 am HRC DIN fuse link A 690V 80kA NH00 am HRC DIN fuse link A 690V 80kA NH00 am HRC DIN fuse link A 690V 80kA NH00 am HRC DIN fuse link A 690V 80kA NH00 am HRC DIN fuse link A 500V 120kA NH00 am HRC DIN fuse link A 500V 120kA NH00 am HRC DIN fuse link A 690V 80kA NH1 am HRC DIN fuse link A 500V 120kA NH1 am HRC DIN fuse link A 690V 80kA NH2 am HRC DIN fuse link A 690V 80kA NH2 am HRC DIN fuse link A 500V 120kA NH2 am HRC DIN fuse link A 690V 80kA NH3 am HRC DIN fuse link A 500V 120kA NH3 am HRC DIN fuse link A 500V 120kA NH4 am HRC DIN fuse link A 500V 120kA NH4 am HRC DIN fuse link A 500V 120kA NH4 am HRC DIN fuse link gs RAPIDPLUS high-speed fuse-links for semi-conductors RAPIDPLUS NH gs fuse links clear all s of overcurrents, overloads and short-circuits, protecting semiconductors, cables and switchgear of the installation. Optimized for reduced power dissipation, permitting utilization of a wide range of applications. Typical application comprise protection of semiconductors (diodes, thyristors, triacs, etc) used in power rectifiers, UPS, converters, motor drives, soft starters, solid state relays, photovoltaic inverters, welding inverters to protect semiconductor devices A 690V 100kA NH000 gs HRC DIN fuse link A 690V 100kA NH000 gs HRC DIN fuse link A 690V 100kA NH000 gs HRC DIN fuse link A 690V 100kA NH000 gs HRC DIN fuse link A 690V 100kA NH000 gs HRC DIN fuse link A 690V 100kA NH000 gs HRC DIN fuse link A 690V 100kA NH000 gs HRC DIN fuse link A 690V 100kA NH000 gs HRC DIN fuse link A 690V 100kA NH00 gs HRC DIN fuse link A 690V 100kA NH00 gs HRC DIN fuse link A 690V 100kA NH1 gs HRC DIN fuse link A 690V 100kA NH1 gs HRC DIN fuse link A 690V 100kA NH2 gs HRC DIN fuse link A 690V 100kA NH2 gs HRC DIN fuse link A 690V 100kA NH2 gs HRC DIN fuse link A 690V 100kA NH3 gs HRC DIN fuse link A 690V 100kA NH3 gs HRC DIN fuse link Fuse bases for above (see page B-39) Isolating link blades for NH fuse bases A 690V 1 pole NH000/00 isolating neutral link blades A 690V 1 pole NH1 isolating neutral link blades A 690V 1 pole NH2 isolating neutral link blades A 690V 1 pole NH3 isolating neutral link blades A 690V 1 pole NH4 isolating neutral link blades B-38

40 NH industrial DIN fuse bases ST series fuse bases for NH fuse-links Self-extinguishing polyamide body / silver plated copper contacts Rated voltage: 690V Standards: IEC/EN , IEC/EN , DIN43620 rated current for fuse size poles qty per pack ST series NH fuse bases Single pole A NH000/00 1 pole industrial NH fuse base A NH1 1 pole industrial NH fuse base A NH2 1 pole industrial NH fuse base A NH3 1 pole industrial NH fuse base A NH4 1 pole industrial NH fuse base Three pole (supplied with seperating phase barriers between fuses) A NH000/00 3 pole industrial NH fuse base A NH1 3 pole industrial NH fuse base A NH2 3 pole industrial NH fuse base A NH3 3 pole industrial NH fuse base DIN rail and chassis screw mount Sectionable neutral NH bases Neutral link base (can be mounted directly onto sides of fuse base) A NH00 1 pole sectionable neutral terminal A NH1 1 pole sectionable neutral terminal A NH3 1 pole sectionable neutral terminal NH fuse holder accessories Partition walls (NH00/1/2/3 require conectors to mount) A NH00 partition walls for fuse bases A NH1/2 partition walls for fuse bases A NH3 partition walls for fuse bases A NH4 partition walls for fuse bases Screws directly onto chassis plate (does not mount onto fuse base) Connectors (to connect two bases together - accepts partition wall) A NH00 separators for fuse bases A NH1/2 separators for fuse bases A NH3 separators for fuse bases Terminal covers (to protect connection terminals of fuse holders) A NH00 1 pole terminal cover for bases A NH00 3 pole integral terminal cover A NH1 1 pole terminal cover for bases A NH2 1 pole terminal cover for bases A NH3 1 pole terminal cover for bases Partition walls incorporated Fuse-link covers (connects onto terminal covers) A NH00 hinged covers for fuse link A NH1/2 hinged covers for fuse link A NH3 hinged covers for fuse link Complete fuse base protection kits (for fuse and terminal insulation protection IP20) Comprises - partition walls - terminal cover - fuse cover A NH1 3 pole IP20 full protection kit A NH2 3 pole IP20 full protection kit A NH3 3 pole IP20 full protection kit Accessories for NH fuse-links Microswitch (mounts directly onto fuse-links) A 250Vac 1 pole NH000-3 micro switch for NH fuses Fuse removal handle (universal for all sizes fuse-links) universal handle NH00-4 fuse replace/removal handle B-39

41 Bolted HRC fuse links (BS88) FSA FGN... Industrial protection HRC fuses Rated voltage: 500 Vac Rated breaking capacity: 80 ka Standards specification: BS88-2, IEC Fuse class: gg/q1 rated BS88 rated breaking fixing body current ref. voltage capacity centres dia. (mm) (GEC) Off-set blade tag fuses (F1) body length 60 mm FGN 02A 2A A1/NP 500V 80kA offset blade 14.2 mm NS FGN 04A 4A A1/NP 500V 80kA offset blade 14.2 mm NS FGN 06A 6A A1/NP 500V 80kA offset blade 14.2 mm NS FGN 10A 10A A1/NP 500V 80kA offset blade 14.2 mm NS FGN 16A 16A A1/NP 500V 80kA offset blade 14.2 mm NS FGN 20A 20A A1/NP 500V 80kA offset blade 14.2 mm NS FGN 25A 25A A1/NP 500V 80kA offset blade 14.2 mm NS FGN 32A 32A A1/NP 500V 80kA offset blade 14.2 mm NS FSS... Off-set bolted tag (A2) body length 86 mm FSA 02A 2A A2 500V 80kA 73 mm 21.5 mm TIA FSA 04A 4A A2 500V 80kA 73 mm 21.5 mm TIA FSA 06A 6A A2 500V 80kA 73 mm 21.5 mm TIA FSA 10A 10A A2 500V 80kA 73 mm 21.5 mm TIA FSA 16A 16A A2 500V 80kA 73 mm 21.5 mm TIA FSA 20A 20A A2 500V 80kA 73 mm 21.5 mm TIA FSA 25A 25A A2 500V 80kA 73 mm 21.5 mm TIA FSA 32A 32A A2 500V 80kA 73 mm 21.5 mm TIA FSDCP... Off-set bolted tag (A3) body length 90 mm FSS 40 40A A3 500V 80kA 73 mm 21.5 mm TIS FSS 50 50A A3 500V 80kA 73 mm 21.5 mm TIS FSS 63 63A A3 500V 80kA 73 mm 21.5 mm TIS FSFP... Off-set bolted tag (A4) body length 111 mm FSDCP 63 63A A4 500V 80kA 94 mm 32 mm TCP FSDCP 80 80A A4 500V 80kA 94 mm 32 mm TCP FSDCP A A4 500V 80kA 94 mm 32 mm TCP Off-set bolted tag (A4) body length 111 mm FSFP A A4a 500V 80kA 94 mm 39.5 mm TFP FSFP A A4a 500V 80kA 94 mm 39.5 mm TFP FSFP A A4a 500V 80kA 94 mm 39.5 mm TFP FSK... Central bolted tag (B2) body length 132 mm FSF A B2 500V 80kA 111 mm 39.5 mm TF FSF A B2 500V 80kA 111 mm 39.5 mm TF Central bolted tag (B3) body length 136 mm FSK A B3 500V 120kA 111 mm 50.5 mm TKF FSK A B3 500V 120kA 111 mm 50.5 mm TKF FMF... Central bolted tag (B4) body length 136 mm FMF A B4 500V 80kA 111 mm 50.5 mm TMF FMF A B4 500V 80kA 111 mm 50.5 mm TMF FTM... Central bolted tag (C2) body length 208 mm FTM A C2 500V 80kA 133/184 mm 70.2 mm TTM FTM A C2 500V 80kA 133/184 mm 70.2 mm TTM B-40

42 Switch disconnectors AC-21A AC-23A dimensions (mm) 690V 415V (H) (W) (D) GA series 3-pole load-break switches (4th pole attachable) Modular design DIN rail mountable supplied with direct mounted handle Door interlocking handle and shaft (to be ordered seperately) GA016A GA016A 16A 7.5kW 3-pole load-break switch GA025A 25A 11.0kW 3-pole load-break switch GA032A 32A 15.0kW 3-pole load-break switch GA040A 40A 18.5kW 3-pole load-break switch GA063SA 63A 22.0kW 3-pole load-break switch GA080A 80A 45.0kW 3-pole load-break switch GA125A 125A 55.0kW 3-pole load-break switch Direct door mounting version (rear access terminals) with shaft 25-40A mounts through standard Ø22mm hole or chassis screw mount. GA040C GA025C 25A 11.0kW 3-pole load-break switch GA040C 40A 18.5kW 3-pole load-break switch GA080C 80A 45.0kW 3-pole load-break switch GA125C 125A 55.0kW 3-pole load-break switch Parallel attachment to convert 3/4 pole switches to 6/8 pole Used to combine two switches side-by-side to make up a 6/8 pole switch GAX6000 parallel attachment for combining 2 switches (6/8 pole) GA016-40A GAX6001 parallel attachment for combining 2 switches (6/8 pole) GA0638A-125A GA080C Changeover attachment for switches GAX5000 changeover mechanism interlock for 2 switches GA016-63A GAX5001 changeover mechanism interlock for 2 switches GA A GAX67B black door interlocking handle (I-O-II) for above changeover mechanisms Handles (external front operation) (IP65) External door interlocking handles padlockable (3 padlocks) in off position GAX1011A GAX61 red/yellow door interlocking recessed handle (screw fixing) GA016-63A/C GAX632 red/yellow door interlocking handle (ring fix Ø 22mm hole) GA016-63A GAX63 red/yellow door interlocking handle (ring fix Ø 22mm hole) GA016-40A/C GAX64 red/yellow interlocking handle (ring fix Ø 22mm defeatable) GA016-63A GAX66 red/yellow door interlocking pistol grip handle (screw fixing) GA A Requires GAX60B adaptor (below) and 7mm sq extension shaft GAX60B adaptor to accommodate 7mm sq shaft required for handles GAX66/66B GAX61 GAX7200 GAX63 Extension shafts (for above switches/handles) GAX mm 5mm extension shaft for switches GA A GAX mm 5mm extension shaft for switches GA A GAX7200A 200mm 7mm extension shaft for handles GAX66/66B GAX7300A 300mm 7mm extension shaft for handles GAX66/66B Auxiliary contact blocks (Ith 16A) GAX1011A 1NO + 1NC auxiliary for base mount switches GA A GAX1011C 1NO + 1NC auxiliary for direct door mount switches GA C GAX1110EA 1NO (early-break) auxiliary for base mount switches GA016-63A GAX1210EA 1NO (early-break) auxiliary for base mount switches GA A GAX60B Terminal shrouds GAX81 1 pole terminal protection shroud (2 pcs) GA016-63A/C GAX82 1 pole terminal protection shroud (2 pcs) GA A/C GAX83 3 pole terminal protection shroud (2 pcs) GA016-63A/C GAX84 3 pole terminal protection shroud (2 pcs) GA A/C GAX391 3 pole fuse holder for load-break switches 16-32A (for cylindrical 10x38mm fuses) GAX391 3 phase fuse holder attaches directly onto switches: GA016A - 040A B-41

43 Enclosed isolators GAX42040A AC-21A 690V Attachable 4th pole for standard switches GAX42040A 40A attachable 4th pole for above switches GA016-40A GAX42063SA 63A attachable 4th pole for above switches GA016-63A GAX42125A 125A attachable 4th pole for above switches GA A GAX41040A 40A attachable early-make 4th pole for above switches GA016-63A GAX41125A 125A attachable early-make 4th pole for above switches GA A Attachable 4th pole for door mount switches GAX42040C 40A attachable 4th pole for above switches GA016-40C GAX42125C 125A attachable 4th pole for above switches GA C GAX41040C 40A attachable early-make 4th pole for above switches GA016-40C GAX41125C 125A attachable early-make 4th pole for above switches GA C Enclosed Isolators GA series enclosed switch disconnectors are supplied in robust, heavy duty enclosures made of ABS material in an IP65 execution with a sealable front cover. The enclosures incorporate a red/yellow operating handle mechanically interlocked with cover in ON position, padlockable (3 padlocks) in the OFF position. AC-21A AC-23A dimensions (mm) 690V 415V (H) (W) (D) Enclosed isolators three pole (IP65) GAZ025 GAZ016 16A 7.5kW 3-pole enclosed load-break switch GAZ025 25A 11.0kW 3-pole enclosed load-break switch GAZ032 32A 15.0kW 3-pole enclosed load-break switch GAZ040 40A 18.5kW 3-pole enclosed load-break switch GAZ063EM 63A 22.0kW 3-pole enclosed load-break switch GAZ080C 80A 45.0kW 3-pole enclosed load-break switch GAZ125CEM 125A 55.0kW 3-pole enclosed load-break switch For 4 pole please add attachable 4th pole (above) Enclosed isolators four pole (IP65) GAZ016 T4EM 16A 7.5kW 4-pole enclosed load-break switch GAZ032 T4EM 32A 15.0kW 4-pole enclosed load-break switch GAZ040 T4EM 40A 18.5kW 4-pole enclosed load-break switch GAZ063 T4EM 63A 22.0kW 4-pole enclosed load-break switch GAZ080C T4EM 80A 45.0kW 4-pole enclosed load-break switch GAZ125C T4EM 125A 55.0kW 4-pole enclosed load-break switch (Empty enclosures see page H-4) GAZ040 T4EM B-42

44 Industrial electronic earth leakage relays Industrial electronic earth leakage relays LED indication (Green Power ON ) ( Red TRIP) Front TEST and RESET buttons Configurable automatic or manual reset Configurable tripping set-point (I n): A / A / A Configurable tripping time delay (t): s / 0.2-5s Reference standards: IEC/EN , IEC/EN /3 supply voltage relays Panel mount earth leakage relays (96 x 96 mm) Require torroidal current transformers (listed below) R1D 1 operational threshold R1D V 1 earth leakage 1 operational threshold R4D 415 R2D 2 operational thresholds (configurable for 2 tripping or 1 + alarm) R2D V 2 earth leakage 2 operational threshold R4D 2 operational thresholds (configurable for 2 tripping or 1 + alarm) Flag indicator (TRIP MEMORY) Digital fault current measurement and display with configurable tripping value R4D V 2 earth leakage 2 operational threshold Toroidal current transformers for above earth leakage devices hole size RT60 60 mm toroidal transformer for above relays RT80 80 mm toroidal transformer for above relays RT mm toroidal transformer for above relays RT mm toroidal transformer for above relays RTA mm split-core toroidal transformers RTA mm split-core toroidal transformers RT... Earth leakage device incorporating toroidal transformer RC Vac/dc 60 mm earth leakage and toroidal combinations RC V 60 mm earth leakage and toroidal combinations RC V 80 mm earth leakage and toroidal combinations RC V 110 mm earth leakage and toroidal combinations RC B-43

45 Electronic earth leakage protection relays D30 Electronic relays with adjustable sensitivity and time delay - Sensitivity: adjustable from 0.03 A - 30 A - Trip time delay: adjustable from 0.02 s - 5 s Suitable for direct pulse current Immune to external disturbances DIN rail mounting sensitivity trip time delay Electronic earth leakage protection relays Slimline only 22.5mm wide (require external toroidal transformer) (H) 80 x (W) 22.5 x (D) 100 mm D A - 30A s electronic earth leakage relay Modular DIN rail mounting (H) 89 x (W) 52.5 x (D) 73 mm DM A - 30A s modular electronic earth leakage relay DR30A DR30A As above, but with automatic reclosing up to 3 attempts with adjustable (1 to 60 s) time Toroidal transformers for above earth leakage relays inner ø core CT1-1/35 35 mm closed torroidal transformer for earth leakage relays CT1-1/60 60 mm closed torroidal transformer for earth leakage relays CT1-1/80 80 mm closed torroidal transformer for earth leakage relays CT1-1/ mm closed torroidal transformer for earth leakage relays CT1-1/ mm closed torroidal transformer for earth leakage relays CT1-1/110 CTA-1/ mm split core torroidal transformer for earth leakage relays CTA-1/ mm split core torroidal transformer for earth leakage relays CT1-1/35 B-44

46 Surge protection devices Modular plug-in surge protection devices SANS/IEC For the protection of low voltage equipment against transient voltages and current surges from atmospheric origins (lightning) as well as transients produced by switching characteristics such as in switching of distribution networks, transformers, motors, ect. PSC2-25/230 TT IR Provides protection for even most sensitive equipment (IEC category-1) Clear lifetime indication (on front face) and optional remote (IR) end of life signalling contact Meets all current international standards (IEC / IEC 62305, etc.) Plug-in cartridges for quick and easy replacement of damaged cartridges Suitable for all s of applications: residential, commercial and industrial Iimp L-N Imax L-N Uc Up L-N width in poles config. (ka) (ka) Volts (kv) 18 mm new PSC4-25/400 TT IR Class 1+2 Surge Protection Devices (combined in a single device) Suitable for first level of protection with incoming power supply panels and areas with greater exposure to lightning. For installations usually provided with external lightning protection systems. Capable of protecting equipment from direct lightning strikes High discharge capacity 10/350 μs: 12.5 ka or 25 ka per phase Provides protection for most sensitive equipment (IEC category 1) Iimp (10/350) 25 ka per phase, I total 50 ka (2 pole) and 100 ka (4 pole) PSC2-25/230 TT 25 ka 100 ka 275 V < 1.5 kv 2 1ph+N PSC2-25/230 TT IR 25 ka 100 ka 275 V < 1.5 kv 2 1ph+N PSC4-25/400 TT 25 ka 100 ka 275 V < 1.5 kv 4 3ph+N PSC4-25/400 TT IR 25 ka 100 ka 275 V < 1.5 kv 4 3ph+N Iimp (10/350) 12.5 ka per phase, I total 25 ka (2 pole) and 50 ka (4 pole) PSC2-12.5/230 TT 12.5 ka 65 ka 275 V < 1.3 kv 2 1ph+N PSC2-12.5/230 TT IR 12.5 ka 65 ka 275 V < 1.3 kv 2 1ph+N PSC4-12.5/400 TT 12.5 ka 65 ka 275 V < 1.3 kv 4 3ph+N PSC4-12.5/400 TT IR 12.5 ka 65 ka 275 V < 1.3 kv 4 3ph+N CSH1-50/230 Class 1 Surge Protection Devices (monoblock device) Monoblock device (does not accept replacement cartridges) CSH1-50/ ka 50 ka < 2.0 kv 1 1ph CSH1-100N 100 ka 100 ka < 2.0 kv 1 N PSM1-40/230 PSM2-40/230 TT Class 2 Surge Protection Devices Suitable for second level of protection with distribution panels where 1 protectors are installed upstream or in areas not exposed to direct lightning strikes and with no external lightning protection High discharge capacity tested with an 8/20 μs waveform: 20kA or 40 ka per phase Provides protection for most sensitive equipment (IEC category 1) Imax 40 ka (8/20μs) PSM1-40/ ka 275 V < 1.3 kv 1 1ph PSM1-40N 40 ka 275 V < 1.3 kv 1 N PSM2-40/230 TT 40 ka 275 V < 1.3 kv 2 1ph+N PSM2-40/230 TT IR 40 ka 275 V < 1.3 kv 2 1ph+N PSM4-40/400 TT 40 ka 275 V < 1.3 kv 4 3ph+N PSM4-40/400 TT IR 40 ka 275 V < 1.3 kv 4 3ph+N Imax 20 ka (8/20μs) PSM1-20/ ka 320 V < 1.4 kv 1 1ph PSM1-20N 20 ka 255 V < 1.4 kv 1 N PSM2-20/230 TT 20 ka 320 V < 1.4 kv 2 1ph+N PSM2-20/230 TT IR 20 ka 320 V < 1.4 kv 2 1ph+N PSM4-20/400 TT 20 ka 320 V < 1.4 kv 4 3ph+N PSM4-20/400 TT IR 20 ka 320 V < 1.4 kv 4 3ph+N With signalling contacts for remote indication/monitoring of devices PSM4-40/400 TT B-45

47 Surge protection devices PSM1-30/750 Iimp L-N Imax L-N Uc Up L-N (ka) (ka) Volts (kv) for surge protector Class 2 surge protection Devices for higher voltage applications ( V) Suitable for second level of protection with distribution panels where 1 protectors are installed upstream or in areas not exposed to direct lightning strikes and with no external lightning protection. Rated varistor voltage Uc = 750Vac / Imax 30kA (8/20μs) Un 690Vac Imax 30kA (8/20μs) PSM1-30/ ka 750 V < 3.0 kv 1 1ph PSM1-30/750 IR 30 ka 750 V < 3.0 kv 1 1ph PSM3-30/750 TNC 30 ka 750 V < 1.3 kv 3 3ph PSM3-30/750 TNC IR 30 ka 750 V < 1.3 kv 3 3ph With signalling contacts for remote indication/monitoring of devices Surge protection for 600/1000 Vdc photovoltaic applications available on page G-4 PSM-40/230 Spare replacement plug-in cartridges for surge arrestors Class 1+2 PSC12.5/ ka 65 ka 275 V < 1.3 kv PSC2/ phase PSC 25/ ka 100 ka 275 V < 1.5 kv PSC2/4-25 phase PSC 25N 25 ka 65 ka 255 V < 1.5 kv PSC neutral PSC 50N 50 ka 65 ka 255 V < 1.5 kv PSC neutral PSC 50N2 50 ka 65 ka 255 V < 1.5 kv PSC2-25 neutral PSC 100N 100 ka 100 ka 255 V < 1.5 kv PSC4-25 neutral Class 2 PSM-20/ ka 320 V < 1.4 kv PSM1/2/4-20 phase PSM-40/ ka 275 V < 1.3 kv PSM1/2/4-40 phase PSM-30/ ka 750 V < 3.0 kv PSM1/3-30 phase PSM-20N 20 ka 255 V < 1.5 kv PSM1/2/4-20 neutral PSM-40N 40 ka 255 V < 1.5 kv PSM1/2/4-40 neutral B-46

48 Overvoltage protection power frequency overvoltage (POP) Besides transient overvoltages, transmission lines can transmit a power frequency overvoltage above 10% of nominal for an indefinite period, caused by network problems, bad connections, damage/theft of the neutral conductor. Electrical distribution systems use the neutral conductor (usually grounded) as a reference for phase voltages, the return current through this conductor permits the voltage between each phase and neutral to remain constant, should the neutral conductor break, the line-to-neutral voltage is floating, and depending on the load imbalance, increases voltage causing premature ageing, excessive consumption with a resulting fire risk. surge protection device POP MCB general Imax L-N Up L-N Ua C curve break poles config. mod. (ka) (kv) (V) (In) capacity (18mm) V-CHECK - surge protection + POP + self reclose MCB in a single unit V-CHECK RPT Transient (surge) protection Power frequency Overvoltage Protection (POP) Overload and short circuit protection Self-reclose MCB (automatically resets once fault is cleared) V-CHECK 2MR ka 1.5 kv >275 V 10A 6 ka 2 1ph+N V-CHECK 2MR ka 1.5 kv >275 V 25A 6 ka 2 1ph+N V-CHECK 2MR ka 1.5 kv >275 V 40A 6 ka 2 1ph+N V-CHECK 4MR ka 1.5 kv >275 V 16A 10 ka 4 3ph+N V-CHECK 4MR ka 1.5 kv >275 V 32A 10 ka 4 3ph+N V-CHECK 4MR ka 1.5 kv >275 V 63A 10 ka 4 3ph+N Above also available without self-reclose facility V-CHECK RPT offers SPD+POP protection disconnecting the circuit via a circuit breaker shunt trip V-CHECK 4RPT 40 ka 1.8 kv >275 V 4 3ph+N V-CHECK RC offers SPD+POP protection disconnecting the circuit via a contactor V-CHECK 4RC 40 ka 1.8 kv >275 V 4 3ph+N OVERCHECK line monitoring unit protection against permanent overvoltages and short circuits OVERCHECK 2N-MT32 OVERCHECK is a programmable control unit and motorised circuit breaker which automatically disconnects the supply when voltage, current or earth leakage exceed preset threshold values, and re-connects the supply when these return to within their preset values. The OVERCHECK provides comprehensive protection of people and equipment connected to the grid, and its safe reconnection feature guarantees maximum service continuity. OVERCHECK 4N-MT63 Plug & play, supplied pre-wired automatic motorised circuit breaker, quick and simple to install Mini USB connection for quick and simple software updates Memory with historical fault log /programmable trip and delay thresholds / password protected End of cycle of reconnections after overload, short circuit or earth leakage / status indication Remote actuation: RST remote reset function / AUX external activation signal contacts Permanent under / over voltage, phase sequence protection (no earth leakage protection) OVERCHECK 2N-MT16 overcheck protection unit 16A 10 ka 2 1ph+N OVERCHECK 2N-MT32 overcheck protection unit 32A 10 ka 2 1ph+N OVERCHECK 2N-MT63 overcheck protection unit 63A 10 ka 2 1ph+N OVERCHECK 4N-MT16 overcheck protection unit 16A 10 ka 4 3ph+N OVERCHECK 4N-MT32 overcheck protection unit 32A 10 ka 4 3ph+N OVERCHECK 4N-MT63 overcheck protection unit 63A 10 ka 4 3ph+N Earth leakage, permanent under / over voltage and phase sequence protection OVERCHECK 2ND-MT16 overcheck protection unit 16A 10 ka 2 1ph+N OVERCHECK 2ND-MT32 overcheck protection unit 32A 10 ka 2 1ph+N OVERCHECK 2ND-MT63 overcheck protection unit 63A 10 ka 2 1ph+N OVERCHECK 4ND-MT16 overcheck protection unit 16A 10 ka 4 3ph+N OVERCHECK 4ND-MT32 overcheck protection unit 32A 10 ka 4 3ph+N OVERCHECK 4ND-MT63 overcheck protection unit 63A 10 ka 4 3ph+N TOCK-30 earth leakage protection transformer for above OVERCHECK... ND G-CHECK continuous ground monitor Earthing monitor for continuous status checking, displays measured value of loop resistance in an installation. When a specified value is exceeded the G-CHECK triggers an alarm output. For TT, TNS and TNC-S systems. voltage frequency alarm activation value max. measured value G-CHECK 230 G-CHECK V 50/60 Hz adjustable 500 ohms B-47

49 Surge protection devices For the protection of low voltage equipment against transient voltage and current surges mainly from atmospheric origin (lightning) and transient produced by switching characteristics such as in switching of distribution networks, transformers, motors, etc. limp L-N lmax L-N Uc Up width in poles config (ka) (ka) (V) (kv) 18 mm DEHNventil Class 1+2 surge protection devices (combined in a single unit) For installation in conformity with the lightning protection zone concept SANS at boundries O A - 2. Combined lightning current and surge arrester Replaceable plug-in modules Visual fault indication Clamps voltage to less than 1500V as per SANS :2008 table L ka 100 ka 255 V <1.5kV 2 1ph+N ka 100 ka 255 V <1.5kV 2 1ph+N ka 100 ka 255 V <1.5kV 4 3ph+N ka 100 ka 255 V <1.5kV 4 3ph+N Class 1 surge protection device with backup fuse ka 255 V <1.5kV 1 ph ka 255 V <1.5kV 1 ph ka 255 V <1.5kV 1 N ka 255 V <1.5kV 1 N DEHNguard Class 2 surge protection devices Minimum requirement as per SANS :2008 anex L for use in all electrical - distribution boards and sub boards. For installation in conformity with the lightning protection zone concept SANS at boundries O B Replaceable plug-in modules Visual fault indication Clamps voltage to less than 1500V as per SANS :2008 table L1 Imax 40kA (8/20μs) ka 275 V <1.25kV 1 ph ka 275 V <1.25kV 1 ph ka 275 V <1.5kV 1 N ka 275 V <1.5kV 1 N ka 275 V <1.25kV 2 1ph+N ka 275 V <1.25kV 2 1ph+N ka 275 V <1.25kV 4 3ph+N ka 275 V <1.25kV 4 3ph+N Class 2 surge protection device with backup fuse ka 25 ka 275 V <1.5 kv 2 1ph+N ka 25 ka 275 V <1.5 kv 2 1ph+N ka 25 ka 275 V <1.5 kv 4 3ph+N ka 25 ka 275 V <1.5 kv 4 3ph+N With signalling contacts for remote indication/monitoring of devices For photovoltaic (PV) surge protection see page G B-48

50 Power supplies Power supplies CliQ series, from the worlds leading power supply manufacturer offers state-of-the-art designs made to withstand harsh industrial environments in accordance with ATEX requirements. The rugged ultra-compact case is both shock and vibration resistant according to IEC Certification: UL508, EN 60950, culus 60950, EN 50178, EN 60204, GS, CCS Aus DRP024V060W1AZ Product features: RoHS compliant Ease of wiring and handling Wide input voltage range 85 to 264Vac (1 phase) to 600Vac (3 phase) Provides - overload, overvoltage and thermal protection Power boost 150% for 3 secs (enables reserve power for reliable startup of loads with high inrush currents) Conformal coating on PCBA to protect against chemical and dust pollutants Hazardous locations approval to ATEX and Class I, Div 2 (for selected models) DIN rail mounting input output rated load dimensions (mm) housing voltage voltage (W) (A) (H) (W) (D) CliQ DIN rail mounting Universal AC input voltage without power de-rating Power Boost of 150% for 3 seconds (24V/480W: 200% for 2 seconds) Full corrosion resistant aluminium chassis Conforms to harmonic current IEC/EN , Class A Operating temperature: -20 C to +80 C 12Vdc output DRP024V240W1AA DRP012V015W1AZ 85~264Vac 12Vdc (adj) plastic DRP012V030W1AZ 85~264Vac 12Vdc (adj) plastic DRP012V060W1AA 85~264Vac 12Vdc (adj) 60 5 aluminium DRP012V100W1AA 85~264Vac 12Vdc (adj) aluminium Vdc output DRP-24V48W1AZ 85~264Vac 24Vdc (adj) 48 2 plastic DRP024V060W1AZ 85~264Vac 24Vdc (adj) plastic DRP024V120W1AA 85~264Vac 24Vdc (adj) aluminium DRP024V240W1AA 85~264Vac 24Vdc (adj) aluminium DRP024V480W1AA 85~264Vac 24Vdc (adj) aluminium CliQ II DIN rail mounting CliQ II DIN rail Power Supplies are high efficiency, high specification units featuring IP20 pluggable terminals and incorporated overvoltage, overload and over temperature protection on the output. DRP024V... Universal AC input voltage without power de-rating High efficiency > 230Vac Power Boost of 150% for 5 seconds Full corrosion resistant aluminium chassis Conforms to harmonic current IEC/EN , Class A Operating temperature: -25 C to +80 C 24Vdc output DRP024V060W1BN 85~264Vac 24Vdc (adj) aluminium DRP024V120W1BN 85~264Vac 24Vdc (adj) aluminium DRP024V240W1BN 85~264Vac 24Vdc (adj) aluminium DRP024V480W1BN 85~264Vac 24Vdc (adj) aluminium Vdc output DRP048V060W1BN 85~264Vac 48Vdc (adj) aluminium DRP048V120W1BN 85~264Vac 48Vdc (adj) aluminium DRP048V240W1BN 85~264Vac 48Vdc (adj) aluminium DRP048V480W1BN 85~264Vac 48Vdc (adj) aluminium Three phase Vac - 24Vdc output DRP048V060W1BN DRP024V060W3BN 320~600Vac 24Vdc (adj) aluminium DRP024V120W3BN 320~600Vac 24Vdc (adj) aluminium DRP024V240W3BN 320~600Vac 24Vdc (adj) aluminium DRP024V480W3BN 320~600Vac 24Vdc (adj) aluminium DRP024V960W3BN 320~600Vac 24Vdc (adj) aluminium B-49

51 Power supplies new DRC-24V10W1AZ Chrome DIN rail power supply is a compact, modular unit designed for compact cabinets, they feature a broad universal AC input range and are certified to international safety standards ITE and ICE. Compact modular housing (same profile and cut-out as standard MCB s) Class II double insulation (no earth connection required) Universal AC input voltage without power de-rating Conforms to harmonic current IEC/EN , Class A Safety approval to IEC/EN/UL (ITE standard) and UL 508 (industrial standard) DIN rail mounting CHROME series input output rated load voltage voltage (W) (A) modular DIN rail mounting housing dimensions (mm) (H) (W) (D) 12Vdc output DRC-12V30W1AZ 90~264Vac 12Vdc (adj) plastic DRC-12V60W1AZ 90~264Vac 12Vdc (adj) plastic Vdc output DRC-24V10W1AZ 90~264Vac 24Vdc (adj) plastic DRC-24V30W1AZ 90~264Vac 24Vdc (adj) plastic DRC-24V60W1AZ 90~264Vac 24Vdc (adj) plastic DRC-24V100W1AZ 90~264Vac 24Vdc (adj) plastic DRC-24V100W1AZ PMT-12V35W1AA PMT-12V50W1AA DRR-40N Panel mounting (chassis ) enclosed power supplies (single phase) PMT panel mount power supplies offer normal output voltages of 12V and 24V with a wide operating temperature range and can withstand shock and vibration according to IEC , they offer overvoltage and over current protection. PMT meets price demand without compromising quality of components and product specifications. Universal AC input voltage without power de-rating (100/150W selectable by switch) Conforms to harmonic current IEC/EN , Class A High MTBF > 700,000 hrs per Telcordia SR-332 Expected lifetime: 10 years 5Vdc output PMT-5V35W1AA 90~264Vac 5Vdc (adj) 35 7 aluminium PMT-5V50W1AA 90~264Vac 5Vdc (adj) aluminium Vdc output PMT-12V35W1AA 90~264Vac 12Vdc (adj) aluminium PMT-12V50W1AA 90~264Vac 12Vdc (adj) aluminium PMT-12V100W1AA 180~264Vac 12Vdc (adj) aluminium PMT-12V150W1AA 180~264Vac 12Vdc (adj) aluminium Vdc output PMT-24V35W1AA 90~264Vac 24Vdc (adj) aluminium PMT-24V50W1AA 90~264Vac 24Vdc (adj) aluminium PMT-24V100W1AA 180~264Vac 24Vdc (adj) aluminium PMT-24V150W1AA 180~264Vac 24Vdc (adj) aluminium PMT-24V200W1AM 180~264Vac 24Vdc (adj) aluminium PMT-24V350W1AK 180~264Vac 24Vdc (adj) aluminium AC input voltage selectable via switch Complementary modules DIN rail mounting Conformal coating on PCBA to protect against chemical and dust pollutants Hazardous locations approval to ATEX and Class I, Div 2 Redundancy modules Wide input and output range of 22-60Vdc Built-in 2 channel DC OK signal and alarm contact DRR-20N redundancy module 20A aluminium DRR-40N redundancy module 40A aluminium Buffer module Minimum buffering time of 24V/20A Supports parallel connection for extended buffering time DRB-24V020ABN 250ms buffer module 20A aluminium DC-UPS module (without battery) Maximum output current up to 40A for 24V application High MTBF > 500,000 hrs per Telcordia SR-332 Built-in battery polarity protection circuit Built-in relay contacts DRU-24V40ABN DC-UPS module 40A aluminium B-50

52 Power supplies DIN rail mount power supplies Modular DIN rail mounting (aligns with standard MCB s with 45 mm cutout) Rated voltage 12Vdc or 24Vdc High efficiency up to 89% Adjustable output voltage input output rated load dimensions (mm) voltage voltage (A) (W) (H) (W) (D) PSL1M... Protection: short circuit overvoltage input voltage peaks Single-phase Vac (insulated housing) PSL1M Vac 12Vdc PSL1M Vac 12Vdc PSL1M Vac 12Vdc PSL1M Vac 12Vdc PSL1... PSL1M Vac 24Vdc PSL1M Vac 24Vdc PSL1M Vac 24Vdc PSL1M Vac 24Vdc DIN rail mounting (IEC/EN 60715) Rated voltage 24Vdc High efficiency up to 92% Adjustable output voltage PSL Vac 24Vdc PSL Vac 24Vdc PSL Vac 24Vdc 12, Three phase ( Vac) PSL3... PSL Vac 24Vdc PSL Vac 24Vdc PSL Vac 24Vdc B-51

53 Control and safety transformers TR28 Control and safety or isolating transformers Control and safety or isolating single-phase transformers supply high instantaneous power for the correct operation of contactors and other control and switchgear. DIN rail mountable (up to 400VA) High flexibility - several primary rated voltages (with regulation taps +20V or -20V) Serial-parallel secondary bridge pieces for ease of connection High capacity clamp terminals (10 mm 2 up to 400VA / 25mm 2 up to 1250VA) Primary voltages: 240V - 400V - 525V Secondary voltages: 12-24V (or) V (with regulation taps + and - 20V) Protection degree: IP20 protection (finger safe) Thermal class: B (130 C) Class: Class I Frequency: 50/60 Hz Dielectric strength: Primary - secondary > 4.5kV Standards: IEC/EN , IEC/EN /-2-4 /-2-6 power (VA) inrush secondary dimensions (mm) weight t a 25 C t a 40 C VA voltage (H) (W) (D) kg TR 28 - secondary voltage: 12-24V Primary voltage: 240V - 400V - 525V V V V V V V V V V V TR 28 - secondary voltage: V - Primary voltage: 240V - 400V - 525V V V V V V V V V V V B-52

Power distribution & protection

Power distribution & protection 7% Power distribution & protection B B1 Miniature circuit breakers (MCB'S) Hager B-1 6 Earth leakage protection Hager B-6 7 Socomec B-47 Lovato B-48 Modular relays/ contactors/ isolators Hager B-8 9 Modular

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Miniature circuit 3.2 breakers 6kA type B SP. Miniature circuit 3.3 breakers curve B,C&D 10kA and 15kA. Protection Devices

Miniature circuit 3.2 breakers 6kA type B SP. Miniature circuit 3.3 breakers curve B,C&D 10kA and 15kA. Protection Devices Miniature circuit 3.2 breakers 6kA type B SP Miniature circuit 3.3 breakers curve B,C&D 10kA and 15kA Auxiliaries and 3.5 accessories Protection Devices RCCB add-on blocks 3.6 Miniature cicruit 3.8 breakers

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

MCCBs : Low voltage protection devices

MCCBs : Low voltage protection devices MCCBs : Low voltage protection devices H3 MCCBs and trip-free switches to 0 A Easy mounting and safety The new H3 range of MCCBs provides safe and easy solutions for low voltage electrical circuits protection.

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

Breaking and protection devices

Breaking and protection devices Power guide: A complete set of technical documentation Breaking and protection devices 01 Sustainable development 08 Protection against external disturbances 02 Power balance and choice of power supply

More information

COMPLETE SOLUTIONS FOR POWER PROTECTION

COMPLETE SOLUTIONS FOR POWER PROTECTION COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX

More information

20th Dec, aptis range

20th Dec, aptis range list effective 203Price 20th Dec, 203 aptis range aptis range value for money Hager unveils its "value for money" offer - aptis! A range with required features and functionality for safe electrical installations.

More information

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager The RX 3 and DX-E ranges provide essential functions for the protection requirements of people and property in residential and small commercial buildings Two breaking capacities, 4500 and 6000 (IEC 60898-1)

More information

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

(p. 47) (p. 155) (p. 155)

(p. 47) (p. 155) (p. 155) 0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

MCBs and RCDs LR TM 6000

MCBs and RCDs LR TM 6000 MCBs and RCDs LR TM 6000 thermal magnetic MCBs from 6 A to 63 A B and C curves residual current devices from 25 A to 63 A AC and A types ± ± ± ± MCBs Single pole 230/400 V± Single pole neutral 230 V± (1)

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break

More information

Power protection solutions

Power protection solutions Power protection solutions DMX A.C.Bs UP TO 4000 A In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT 44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi Contents Miniature circuit breakers ic60n miniature circuit breakers 6kA, C curve, 6-63A ic60h miniature circuit breakers 10kA, C curve, 6-63A ic60n miniature circuit breakers 6kA, B curve, 6-63A ic60h

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric. K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

KD LV Motor Protection Relay

KD LV Motor Protection Relay 1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage

More information

New DX 3 High rating & breaking capacity

New DX 3 High rating & breaking capacity New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand

More information

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

MC FRAME SIZE 1 / UP TO 160A

MC FRAME SIZE 1 / UP TO 160A 8 W CIRCUIT BREAKER 3 POLE UP TO 160A WITH THERMAL MAGNETIC RELEASE TYPES MC1B-A, MC1N-A, MC1H-A For system and line protection Adjustable overload release Ir: 0,8 1 x In (factory setting 0,8 x In) Adjustable

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

MCCB Accessories to suit AF

MCCB Accessories to suit AF MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal

More information

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com Multi 9 TM Catalogue 207 Multistandard protection for OEM schneider-electric.com Green Premium TM Endorsing industry eco-friendly products Schneider Electric s Green Premium ecolabel is committed to offering

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS 87045 LIMOGES Cedex Phone : + 33 5 55 06 87 87 Fax : + 33 5 55 06 88 88 R.C.B.O. DX 6000 A Phase + Neutral,, neutral on right side Cat. n (s) : 077 31 077 44-077 77 077 84 078 79 079 01-083 95 084 06 084

More information

WORKSHOP SPECIFICATIONS

WORKSHOP SPECIFICATIONS WORKSHOP SPECIFICATIONS DPX 3 160 & 250 MOULDED CASE CIRCUIT BREAKERS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DPX 3 RANGE Not only do DPX³ 160 and DPX 3 250 MCCBs provide

More information

Motor protective circuit breakers

Motor protective circuit breakers Motor protective circuit breakers Motor protective circuit breakers MSP Description The MSP0, MSP1 motor starter protectors are compact motor starter protectors for currents up to 52 A which operate according

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

price list IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

price list IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES price list THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES APRIL 2014 P. 07 P. 08 DMX3 ACB from 630 A to 2500 A Fixed version Draw-out version P. 13 cat.a Ui690V Uimp6kV 50 60Hz

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

Cat N 3. OVERALL DIMENSIONS

Cat N 3. OVERALL DIMENSIONS Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

Residual Current Circuit-breaker (RCCB) FH 200 Series

Residual Current Circuit-breaker (RCCB) FH 200 Series Residual Current Circuit-breaker (RCCB) FH 200 Series Bi-directional cylindrical terminal ensure higher safety of connecting operations, making them easier. Test pushbutton to verify the correct functioning

More information

PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS

PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS FEATURES Robust, durable construction Unique double doors open 180 with minimum projection Light grey colour standard, can be painted to suit décor re quirements

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

DRX 100 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4. MOUNTING 2 5. CABLING 3 6. ELECTRIC AND MECHANICAL

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

up to 63 A (1 module per pole)

up to 63 A (1 module per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions...

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

SENTRON VL Series Product Specifications

SENTRON VL Series Product Specifications SENTRON VL Series Product Specifications VL 400 Frame 400 s Electronic Releases ETU TRIP RELEASE 315 12-315 3VL4731 - A 3-0AA0 400-400 3VL4740 - A 3-0AA0 3 = 3 poles All VL400 circuit-breakers are shipped

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

Btdin RCBO 6000A up to 63A (2P)

Btdin RCBO 6000A up to 63A (2P) Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

EAD10H80D EAD14H80D EAD17H80D

EAD10H80D EAD14H80D EAD17H80D 12.4 Technical data Consumer units and enclosures dimensions and data RCCB controlled surface mounting consumer units Eaton list Dimensions (mm) number w h d EAD2/3M63 154 223 101 EAD2/3M80 EAD4M63 235

More information

Siemens switchgear. Tried, tested, trusted. Circuit Breakers

Siemens switchgear. Tried, tested, trusted. Circuit Breakers * MP - Maximum etail Price Siemens Ltd. LV SG - Power Distribution Products MP Eff. 01-10-2014 13 MCCB: Sentron 3VT1...5 ated current - 16A to 1600A 3 and 4 pole versions Breaking capacity from 25kA to

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial

More information

1 Phase electronic contactor (SC 1)

1 Phase electronic contactor (SC 1) 1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or

More information