W.E. ANDERSON. Series WE05 3-Piece Socket Weld Ball Valve. Specifications - Installation and Operating Instructions.

Size: px
Start display at page:

Download "W.E. ANDERSON. Series WE05 3-Piece Socket Weld Ball Valve. Specifications - Installation and Operating Instructions."

Transcription

1 y wyer eries W05 3-Piece ocket Weld all Valve pecifications - Installation and Operating Instructions ulletin V-W05 W05-H00 W05-A0-AA0 W05-ITI05- W05-A0 W05-JT03-A The RI W05 offers the best possible design for socket weld ball valves. The swing out body feature and seat arrangement allow for trouble-free welding installation. The eries W05 incorporates a full port 3-piece ball valve for ideal flow rates with minimal pressure drop. The valve features a blowout proof stem for added safety, reinforced PT seats and seals for longer life, and a 36 (ATM 8M) ball for better performance. Actuators are directly mounted creating a compact assembly for tight spaces. imit switches can be mounted directly to the valves, allowing for remote position indication. The eries W05 can be configured with either an electric or pneumatic actuator. lectric actuators are available in weatherproof or explosion-proof, a variety of supply voltages and two-position modulating control. Two-position actuators use the supply voltage to drive the valve open or close, while the modulating actuator accepts a 4 to 0 ma input for valve positioning. Actuators feature thermal overload protection and a permanently lubricated gear train. The pneumatic double acting actuator uses an air supply to drive the valve open and closed. The actuator has two supply ports with one driving the valve open and the other driving the valve closed. pring return pneumatic actuators use the air supply to open the valve and internally loaded springs return the valve to the closed position. Also available is the V3 solenoid valve to electrically switch the air supply pressure between the air supply ports for opening and closing the valve. Actuators are constructed of anodized and epoxy coated aluminum for years of corrosion free service. PIIATION VAV ervice: ompatible liquids and gases. ody: 3-Piece. ine izes: / to. nd onnections: ocket weld. Pressure imits: 0 Hg to 000 psi (- to 69 bar). Wetted Materials: ody and ball: 36 (8M); tem: 36 ; eat: RT/ PT; eal, Washer, and Packing: PT. Temperature imits: -0 to 39 (-9 to 0). Other Materials: O-ring: luoroelastomer; Handle: 304 ; Washer: 30 ; tem Nut, ocking evice, Gland Ring: 304 ; Handle leeve: PV. ATUATOR Pneumatic A and R eries Type: A series is double acting and R series is spring return (rack and pinion). Normal upply Pressure: A: 40 to 5 psi (.7 to 7.9 bar); R: 80 psi (5.5 bar). Maximum upply Pressure: 0 psi (8.6 bar). Air onnections: A0: /8 female NPT; A0 to A05: / female NPT; R0 to R07: / female NPT. Housing Material: Anodized aluminum body and epoxy coated aluminum end caps. Temperature imits: -40 to 76 (-40 to 8). Accessory Mounting: NAMUR standard. lectric T and M eries Power Requirements: 0 VA, 0 VA, 4 VA or 4 V (M models not available in 4 V). Power onsumption: ee page 8. ycle Time (per ): T0: 4 s; M0: 0 s; T0 and M0: 0 s; T03 and M03:. uty Rating:. nclosure Rating: NMA 4X (IP67). Housing Material: Powder coated aluminum. Temperature imits: - to 4 (-30 to 6). lectrical onnection: / female NPT. Modulating Input: 4 to 0 ma. tandard eatures: Manual override, position indicator, and T models come with two limit switches. lectric TI and MI eries Power Requirements: 0 VA, 0 VA, 4 VA or 4 V. Power onsumption: ee page 9. ycle Time (per ): ee page 9. uty Rating: ee page 9. nclosure Rating: NMA 7. Housing Material: Powder coated aluminum. Temperature imits: -40 to 4 (-40 to 6). lectrical onnection: / female NPT. Modulating Input: 4 to 0 ma. tandard eatures: Position indicator and two limit switches. W.. ANRON A IVIION O WYR INTRUMNT, IN. P.O. OX 373 MIHIGAN ITY, INIANA 46360, U..A. Phone: 9/ ax: 9/ info@dwyermail.com

2 MO HART ize / 3/ -/ -/ -/ v (gal/min) Popular Hand Operated Model W05-H00 W05-H00 W05-H00 W05-H00 W05-GH00 W05-HH00 W05-IH00 W05-JH00 Popular ouble Acting Pneumatic Model W05-A0 W05-A0 W05-A0 W05-A0 W05-GA03 W05-HA03 W05-IA04 W05-JA05 Popular pring Return Pneumatic Model W05-R0 W05-R0 W05-R03 W05-R03 W05-GR04 W05-HR05 W05-IR07 W05-JR07 Popular NMA 4X Two Position lectric (0 VA) Model W05-T0-A W05-T0-A W05-T0-A W05-T0-A W05-GT0-A W05-HT0-A W05-IT03-A W05-JT03-A Popular NMA 4X Modulating lectric (0 VA) Model W05-M0-A W05-M0-A W05-M0-A W05-M0-A W05-GM0-A W05-HM0-A W05-IM03-A W05-JM03-A VAV I O MATRIA VNT A Item escription ody ap all all eat Joint Gasket tem Thrust Washer tem Packing High Washer elleville Washer tem Nut O-Ring olt pring Washer Hex Nut topper Handle Handle over ock Washer Material ATM A35-8M ATM A35-8M ATM A35-8M PT PT AII 36 PT PT luoroelastomer PV VAV IMNIONA RAWING W H M M H H Ød ØRa ØRb ØRa ØA Ø Ø MO HART Model ize W05-H00 / W05-H00 W05-H00 W05-H00 W05-GH00 W05-HH00 W05-IH00 W05-JH00 3/ -/ -/ -/ Ød H W 9/ -9/6-3/8 4-3/ (5) (65) (60) (0) 5/6-6/6-7/ 4-3/ (0) (75) (64) (0) 63/6 3-/ -59/6 5-53/6 (5) (85) (74) (48) -7/6 3-63/6 3-/8 5-53/6 (3) (0) (79) (48) -/ 4-3/ 3-3/ 7 (38) () (95) (78) 5-/8 4-/6 7 (50) (30) (03) (78) -/ 3-3/8 4-7/ 7 (63) (6) (3) (78) 7-3/ 5-3/6 7 (76) (88) (3.5) (78) Ø Ø 3/6-7/6 -/3 (9) (36) (4) 3/6-7/6 -/3 (9) (36) (4) 7/6 -/ -3/ () (4) (50) 7/6 -/ -3/ () (4) (50) 9/6-3/ -49/6 (4) (50) (70) 9/6-3/ -49/6 (4) (50) (70) 3/ -49/6 4-/6 (9) (70) (0) 3/ -49/6 4-/6 (9) (70) (0) IO ØRa ØRb M 03/04 7/6 7/6 Mx.5 (.75) (.75) 03/04 7/6 7/6 Mx.5 (.75) (.75) 04/05 9/6 7/6 M4x.5 (3.5) (.75) 04/05 9/6 7/6 M4x.5 (3.5) (.75) 05/07 3/6 9/6 M8x.5 (4.5) (3.5) 05/07 3/6 9/6 M8x.5 (4.5) (3.5) 07/0 Ø9/6 Ø3/6 Mx.5 (Ø) (Ø9) 07/0 Ø9/6 Ø3/6 Mx.5 (Ø) (Ø9) v (gal/min)

3 AUTOMAT VAV RAWING W/ PNUMATI ATUATOR NPT OU ATING PNUMATI ATUATOR NPT / 3/ -/ -/ -/ 4-5/8 6 mm -3/8 6 mm -/ 65 mm 4-5/8 6 mm -/ 37 mm 4-3/ 0 mm -3/8 6 mm 75 mm 4-5/8 6 mm -/ 37 mm 5-/ 4 mm -3/ 7 mm 3-3/8 85 mm 5-3/ 45 mm -5/8 4 mm 5-3/ 46 mm -3/ 7 mm 0 mm 5-3/ 45 mm -5/8 4 mm 6-3/ 73 mm 3-/ 8 mm 4-3/8 mm 6-5/8 69 mm -3/ 46 mm 7-/8 8 mm 3-/ 8 mm 5-/8 30 mm 6-5/8 69 mm -3/ 46 mm 8-3/8 mm 3-3/ 94 mm 6 mm 7-7/8 0 mm 5 mm 9 8 mm 0 mm 7-3/8 88 mm 8-/ 09 mm -/8 55 mm PRING RTURN PNUMATI ATUATOR NPT / 3/ -/ -/ -/ 5 8 mm -3/ 7 mm -/ 65 mm 5-3/ 45 mm -5/8 4 mm 5-/8 3 mm -3/ 7 mm 75 mm 5-3/ 45 mm -5/8 4 mm 6-/8 57 mm 3-/ 8 mm 3-3/8 85 mm 6-5/8 69 mm -3/ 46 mm 6 mm 3-/ 8 mm 0 mm 6-5/8 69 mm -3/ 46 mm 7-/ 85 mm 3-3/ 94 mm 4-3/8 mm 7-7/8 0 mm 5 mm 7-7/8 0 mm 0 mm 5-/8 30 mm 8-/ 09 mm -/8 55 mm 9-5/8 45 mm 4-3/ mm 6 mm 0-7/8 75 mm -/ 64 mm 0 53 mm 4-3/ mm 7-3/8 88 mm 0-7/8 75 mm -/ 64 mm W/ TRI ATUATOR O NPT TRI ATUATOR NPT / 3/ -/ -/ -/ 6 mm 5-/ 33 mm -/ 65 mm 6-/8 54 mm -3/ 68 mm 6-/ 65 mm 5-/ 33 mm 75 mm 6-/8 54 mm -5/8 68 mm 8-3/8 mm 9-3/8 39 mm 3-3/8 85 mm 8-/ 7 mm 5 6 mm 8-/ 7 mm 9-3/8 39 mm 0 mm 8-/ 7 mm 5 6 mm 8-7/8 7 mm 9-3/8 39 mm 4-3/8 mm 8-/ 7 mm 5 6 mm 0 53 mm 8-/ 6 mm 5-/8 30 mm 8-/ 6 mm 5-3/8 36 mm 0-3/ 7 mm 8-/ 6 mm 6 mm 8-/ 6 mm 5-3/8 36 mm 80 mm 8-/ 6 mm 7-3/8 88 mm 8-/ 6 mm 5-3/8 36 mm W/ XPOION-PROO TRI ATUATOR OPN NPT XPOION-PROO TRI ATUATOR NPT / 3/ -/ -/ -/ 6-5/8 69 mm 4-/ 3 mm -/ 65 mm 6-/ 60 mm 6-3/ 7 mm 4-/ 3 mm 75 mm 6-/ 60 mm 7-/8 8 mm 4-/ 3 mm 3-3/8 85 mm 6-/ 60 mm 7-3/8 87 mm 4-/ 3 mm 0 mm 6-/ 60 mm 7-3/ 97 mm 4-/ 3 mm 4-3/8 mm 6-/ 60 mm 8-/8 05 mm 4-/ 3 mm 5-/8 30 mm 6-/ 60 mm 9-7/8 50 mm 4-3/ mm 6 mm 7-3/ 96 mm 3-7/8 98 mm 0-/8 58 mm 4-3/ mm 7-3/8 88 mm 7-3/ 96 mm 3-7/8 98 mm 3

4 PNUMATI ATUATOR Note: or optimal operation, pneumatic actuators should be run with a supply of clean, lubricated air. pring Return Actuator Operation Air to PORT (the left hand port) causes the actuator to turn counterclockwise (W). oss of air to PORT causes air to exhaust and the actuator turns clockwise (W). This is the AI O operation. ouble Acting Actuators Operation Air to PORT (the left hand port) causes the actuator to turn counterclockwise (W). Air to PORT (the right hand port) causes the actuator to turn clockwise (W). Pneumatic Actuator Maintenance Routine maintenance of pneumatic actuator: Keep the air supply dry and clean Keep the actuator surface clean and free from dust Periodic checks should be done to make sure all fittings are tight Pneumatic actuators are supplied with lubrication to last the entire life span of the actuator under normal operating conditions. The outer surface of the pneumatic actuator should be clean to avoid friction or corrosion. All fittings and connections should be tight to prevent leaks during operation. heck the bolts mounting the valve to the actuator to make sure they have not come loose during shipping or installation. Make sure the valve and actuator are not rubbing or jamming against other components during operation. The actuator should be inspected annually to make sure all fittings and bolts are tight and nothing has come loose during operation. isassembling Pneumatic Actuators WARNING efore beginning disassembly, ensure that the air supply to the actuator has been disconnected, all accessories have been removed, and that the actuator has been disassembled from the valve.. oosen the end cap fasteners (3) with a wrench (size varies depending on actuator model). On the spring return actuator, alternate 3 to 5 turns on each fastener until the springs are completely decompressed. Use caution when removing the cap since the springs are under load until the fasteners are fully extended.. Remove the pinion snap ring (3) with a lock ring tool. The indicator () may now be removed. 3. Turn the pinion shaft () counterclockwise until the pistons are at the full end of travel. isengage the pistons (5) from the pinion. (T: ow pressure air--3 to 5 psi MAXIMUM--might be required to force the pistons completely from the body.) Note the position of the pistons before removing them from the actuator body. 4. Remove the pinion through the bottom of the actuator. The actuator is now completely disassembled. WARNING Pneumatic Actuators ill of Materials ailures Inspection Items orrective Action Pneumatic actuator won t operate Pneumatic actuator runs slowly. heck the solenoid valve. Is the coil burnt out or is the solenoid spool?. The actuator will not move because of debris in the gears. 3. The pneumatic line to the actuator is distorted or smashed. 4. The pneumatic line is frozen because of low temperatures and moisture.. The air supply pressure is insufficient.. Are other pneumatic devices consuming the air required for the actuator to operate? 3. The pneumatic actuator is undersized for the application. Reassembling Pneumatic Actuators. Replace the solenoid valve coil or remove debris.. isassemble the actuator, clean the debris and reassemble the actuator. 3. Replace pneumatic line to the actuator. 4. Warm the pneumatic lines and remove moisture from supply lines.. Increase the air supply pressure and look for leaks in the supply pressure pipeline.. Increase the air supply or reduce the number of devices operating at the same time. 3. Replace the actuator with a larger actuator. e sure the actuator surfaces are free of debris and scratches before reassembling.. Apply a light film of grease to all O-rings and the pinion before replacing.. Put the pinion () back through the actuator with the flats of the pinion shaft running parallel with the body. 3. When reassembling the actuator, make sure that the piston racks are square to the actuator body and returned to their original orientation. (T: The normal operation of all spring return pneumatic actuators is AI O. To change the orientation to AI OPN, rotate the racks 80º to create a reverse operation. 4. When replacing springs in a spring return actuator, ensure that the springs are replaced in their identical position in the end cap from which they were removed. (T: In some circumstances, you might want to change the standard 80 pound spring set to fit your application and available air pressure. 5. eal the end caps with a petroleum lubricant and bolt to actuator body. 6. heck the seal of the actuator by covering seal areas (pinion, end caps) with soapy water and using low pressure air to the actuator to ensure that no bubbles are produced. 4 Part Number Quantity Part Name Material to 8 ylinder Output haft O-ring earing Adjusting am Thrust earing earing O-ring earing Gasket amping Ring Position Indicator crew Position Indicating Inserts Piston Guide Ring O-ring Guide Ring pring Assembly O-ring eft nd ap Right nd ap nd ap olt O-ring Gasket Nut Adjusting olt xtruded Aluminum Alloy luorine ilicon Rubber Nylon46 Nylon46 Nylon46 luorine ilicon Rubber Nylon46 PPPP+30%G PPPP+30%G PPPP+30%G asting Aluminum Alloy Nylon46 luorine ilicon Rubber luorine-arbon omposite Material Alloy pring teel luorine ilicon Rubber asting Aluminum Alloy asting Aluminum Alloy luorine ilicon Rubber

5 MO HART - OU ATING ATUATOR TORQU A ouble-action Output Torque (lb-in) Air Pressure Model 40 psi 50 psi 60 psi 70 psi 80 psi 90 psi 00 psi 0 psi 5 psi AT-A0 AT-A0 AT-A03 AT-A04 AT-A05 AT-A06 AT-A07 AT-A08 AT-A MO HART - PRING RTURN ATUATOR TORQU R ingle Acting Pneumatic Actuator (lb-in) Air Pressure 70 psi 80 psi 90 psi 00 psi 0 psi 5 psi pring Torque Model pring Quantity nd nd nd nd nd nd nd AT-R0 AT-R03 AT-R04 AT-R05 AT-R06 AT-R07 AT-R08 AT-R09 AT-R TRI ATUATOR lectric Installation. Operate valve manually and place in the open position.. Remove any mechanical stops the valve might have. (O T RMOV ANY PART NARY OR TH PROPR OPRATION O TH VAV, UH A TH PAKING GAN, PAKING NUT, T.) 3. nsure that the actuator output shaft and valve stem are aligned properly. If they are not, operate the valve manually until they are correct. 4. Remove actuator cover. 5. ring power to the actuator. AUTION: Make sure power is O at the main box. 6. Wire the actuator per the diagram attached to the inside of the cover. pecial actuators (those with positioner boards, etc.) will have diagrams enclosed inside the cover. 7. ecurely tighten bolts used to mount the actuator to a mounting bracket or directly to the valve mounting pad if it is IO5 compliant. 8. ycle the unit several times and check the open and closed positions of the valve. ams are pre-adjusted at the factory; due to the variety of valve designs and types however, slight adjustments might be required. 9. Replace cover and tighten screws. To et The losed Position. Apply power to terminals to move the valve toward the closed position. The bottom cam and switch control the closed position. In the closed position, the set screw in the bottom cam will be accessible.. If the valve is not closed completely: A. lightly loosen the set screw on the bottom cam.. Rotate the cam counterclockwise (W) by hand until the switch makes contact. ontact is made when a slight click can be heard. y making incremental W movements of the bottom cam, the valve can be positioned precisely in the desired position.. When the top cam is set, tighten the set screw securely. 3. If the valve closes too far: A. Apply power to terminals. This will begin to rotate valve W. When valve is fully closed and in the exact position desired, remove power from actuator.. oosen the set screw in the top cam.. Rotate the top cam clockwise (W) until the switch arm drops off the round portion of the cam onto the flat section. A slight click can be heard as the switch is no longer making contact with the round part of the cam.. ontinue applying power to terminals until valve is in the desired position. To et The Open Position. ycle the valve to the open position by applying power to terminals. The top cam and switch control this position. In the open position, the set screw in the top cam will be accessible.. If the valve is not open completely: A. lightly loosen the set screw on the top cam.. Rotate the cam clockwise (W) by hand until the switch makes contact. ontact is made when a slight click can be heard. y making incremental W movements of the top cam, the valve can be positioned precisely in the desired position.. When the top cam is set, tighten the set screw securely. 3. If the valve opens too far: A. Apply power to terminals. This will begin to rotate valve W. When valve is fully open and in the exact position desired, remove power from actuator.. oosen the set screw in the top cam.. Rotate the top cam counterclockwise (W) until the switch arm drops off the round portion of the cam onto the flat section. A slight click can be heard as the switch changes state.. ontinue applying power to terminals until valve is in the desired position. 5

6 lectric Actuators Wiring iagram: AT-TI & AT-MI Wiring iagrams for TI0-A to TI05-A: 0 VA, TI0- to TI05-: 0VA, TI0- to -TI05-: 4 VA OPTIONA RAK W. # N P MOTOR APAITOR W. # N OPTIONA HATR & THRMOTAT GROUN RW WITH AYOUT W. # OPN IMIT W. # O IMIT T: POWR TO TRMINA ON & TWO OPN TH VAV (W ROTATION) POWR TO TRMINA ON & THR O TH VAV (W ROTATION) TRMINA 4 & 5 AR OR IGHT INIATION WIRING IAGRAM IUTRAT TH ATUATOR IN TH OPN POITION A.. UPPY POWR N HOT PT ONTRO WITH HOWN OR IUTRATION ONY I WIRING IGHT OR RMOT POITION INIATION OPTIONA QUIPMNT I WIRING Wiring iagrams for TI0- to TI05-: 4 V + - MOTOR ATUATOR HOWN IN OPN POITION W.# W.# WITH # OPN WITH WITH # O WITH W. # N A M W. # A M N OPRATION: POWR TO & OR W ROTATION POWR TO 3 & 4 OR W ROTATION TRMINA 5 & 6 OR I IGHT INIATION ONNTION N N N N O OO O M M OI I WIRING PT WITH HOWN OR IUTRATION ONY - VOTAG RVRING RAY UPPI Y UTOMR + 6

7 Wiring iagrams for M0-A to M03-A: 0 VA, M0- to M03-: 0 VA, M0- to M03-: 4 VA GRN JP4 JUMPR T OR JP AI O UPON JP3 O O ONTRO R IGNA J K OHM AK POTNTIOMTR 4-0mA POITIONR PAN ZRO JP A AN GRN JP4 JP JP3 R U JUMPR T OR AI OPN UPON O O ONTRO IGNA JUMPR A HOWN OW I AI IN AT POITION UPON O O IGNA GRN JP4 JP JP3 R G R N J R K WHT WHT R P MOTOR N K W. U K W. OPTIONA N W.3 W.4 N AUXIIARY WITH N APAITOR RAK OPTIONA W. 4, OPN W. 3, O W., OPN W., O T: ATUATOR HIPP IN OPN POITION, 0mA RPRNT OPN POITION. O T AJUT AK POTNTIOMTR OR IMIT WITH THY AR ATORY T AN O T RQUIR AIRATION. TO AIRAT TH OPN AN O POITION, U TH ZRO (4mA) AN PAN (0mA) TRIM POTNTIOMTR PH-60HZ POWR UPPY HOT N 4-0mA ONTRO IGNA 0-0V or 0-5V ONTRO IGNA RMOV JP, JP3 & JP4 I WIRING HATR & THRMOTAT OPTIONA TO AIRAT, OPRAT ATUATOR TO O POITION AN AJUT WITH ZRO TRIM POT THN OPRAT TO OPN POITION AN T UING PAN TRIM POT. URTHR AIRATION I NARY. OPTIONA QUIPMNT I WIRING WIRING IAGRAM OR Ph/60Hz TRI ATUATOR WITH 4-0mA, 0-5Vdc OR 0-0Vdc ONTRO. Wiring iagrams for MI0- to MI05-: 4 V GRN JP4 JUMPR T OR JP AI O UPON JP3 O O ONTRO R IGNA J JUMPR A HOWN OW I AI IN AT POITION UPON O O IGNA K OHM AK POTNTIOMTR 4-0mA POITIONR PAN ZRO JP A AN GRN JP4 JP JP3 R U GRN JP4 JP JP3 R G R N J R JUMPR T OR AI OPN UPON O O ONTRO IGNA K WHT WHT R P MOTOR N K W. U K W. N AUXIIARY WITH OPTIONA N W.3 W.4 N APAITOR RAK OPTIONA W. 4, OPN W. 3, O W., OPN W., O T: ATUATOR HIPP IN OPN POITION, 0mA RPRNT OPN POITION. O T AJUT AK POTNTIOMTR OR IMIT WITH THY AR ATORY T AN O T RQUIR AIRATION. TO AIRAT TH OPN AN O POITION, U TH ZRO (4mA) AN PAN (0mA) TRIM POTNTIOMTR PH-60HZ POWR UPPY HOT N 4-0mA ONTRO IGNA 0-0V or 0-5V ONTRO IGNA RMOV JP, JP3 & JP4 I WIRING HATR & THRMOTAT OPTIONA TO AIRAT, OPRAT ATUATOR TO O POITION AN AJUT WITH ZRO TRIM POT THN OPRAT TO OPN POITION AN T UING PAN TRIM POT. URTHR AIRATION I NARY. OPTIONA QUIPMNT I WIRING WIRING IAGRAM OR Ph/60Hz TRI ATUATOR WITH 4-0mA, 0-5Vdc OR 0-0Vdc ONTRO. 7

8 lectric Actuators Wiring iagram: AT-T & AT-M Wiring iagrams for T0-A to T03-A: 0 VA, T0- to T03-: 0 VA, T0- to T03-: 4 VA Note: To speed up installation of the control wires to the AT-MXX modulating actuator, it is recommended to remove the control module from the actuator. The control module can be removed by removing the two mounting screws on the left and right of the control module. Install the control wires to the correct terminal points and then reinstall the control module. lectric Actuator Maintenance Once the actuator has been properly installed, it requires no maintenance. The gear train has been lubricated and in most cases will never be opened. uty ycle efinition uty ycle means the starting frequency. ormula: Running Time (Running Time + Rest Time) x 00% = duty cycle > Rest Time = Running Time x ( - duty cycle) duty cycle or example: The running time is econds 30% duty cycle 5 x [( - 30%) / 30%] = 35 > The rest time will be 3econds duty cycle 5 x [( - ) / ] = 5 > The rest time will be econds If the duty cycle is higher, the rest time will be shortened, which means the starting frequency will be higher. Wiring iagrams for T0- to T03-: 4 V Thermal Overload All actuators are equipped with thermal overload protection to guard the motor against damage due to overheating. Mechanical Overload All actuators are designed to withstand stall conditions. It is not recommended to subject the unit to repeated stall conditions. xplosion-proof lectric Actuators Wiring iagrams for MI0-A to MI05-A: 0 VA, MI0- to MI05-: 0 VA, MI0- to MI05: 4 VA WARNING. O T under any circumstances remove the cover of the actuator while in a hazardous location. Removal of the cover while in a hazardous location could cause ignition of hazardous atmospheres.. O T under any circumstances use an explosion-proof electric actuator in a hazardous location that does not meet the specifications for which the actuator was designed. 3. Always verify that all electrical circuits are de-energized before opening the actuator. 4. Always mount and cycle test the actuator on the valve in a non-hazardous location. 5. When removing the cover, care must be taken not to scratch, scar of deform the flame path of the cover and base of the actuator, since this will negate the NMA rating of the enclosure. 6. When replacing the cover, take care that the gasket is in place to assure proper clearance after the cover is secured. 7. All electrical connections must be in accordance with the specifications for which the unit is being used. 8. hould the unit ever require maintenance, remove from the hazardous location before attempting to work on the unit. If the actuator is in a critical application, it is advisable to have a standby unit in stock. 8

9 lectric Actuators Performance Rating T0 ycle Time uty ycle (Two-Position) AMP raw Torque M0 ycle Time M0 uty ycle (Modulating) AMP raw Torque 0 VA 4 s 0.4 A 77 in-lb 0 VA 0 s 0.4 A 65 in-lb 0 VA 4 s 0.6 A 77 in-lb 0 VA 0 s 0.6 A 65 in-lb 4 VA 4 s 0.8 A 77 in-lb 4 V 4 s.8 A 77 in-lb 4 VA 0 s.8 A 65 in-lb MAINTNAN/RPAIR Upon final installation of the eries W, only routine maintenance is required. The eries W is not field serviceable and should be returned if repair is needed. ield repair should not be attempted and may void warranty. WARRANTY/RTURN Refer to Terms and onditions of ale in our catalog and on our website. ontact customer service to receive a Return Goods Authorization number before shipping the product back for repair. e sure to include a brief description of the problem plus any additional application notes T0 and M0 (M Not Available in 4 V) ycle Time uty ycle (Two-Position) uty ycle (Modulating) AMP raw Torque 0 VA 0 s 0.4 A 44 in-lb 0 VA 0 s 0.6 A 44 in-lb 4 VA 0 s.8 A 44 in-lb 4 V 0 s -.8 A 44 in-lb T03 and M03 (M Not Available in 4 V) ycle Time uty ycle (Two-Position) uty ycle (Modulating) AMP raw Torque 0 VA 0.57 A 885 in-lb 0 VA 0.35 A 885 in-lb 4 VA.03 A 885 in-lb 4 V -.03 A 885 in-lb TI0 ycle Time uty ycle (Two-Position) ull oad AMP raw Torque (in-lb) 0 VA VA VA V TI0 and MI0, MI0 ycle Time (Two-Position) ycle Time (Modulating) uty ycle (Two-Position) uty ycle (Modulating) ull oad AMP raw Torque (in-lb) 0 VA 0 s VA 0 s VA 00 4 V 00 TI03 and MI03 ycle Time (Two-Position) ycle Time (Modulating) uty ycle (Two-Position) uty ycle (Modulating) ull oad AMP raw Torque (in-lb) 0 VA 0 s VA 0 s VA V 300 TI04 and MI04 ycle Time (Two-Position) ycle Time (Modulating) uty ycle (Two-Position) uty ycle (Modulating) ull oad AMP raw Torque (in-lb) 0 VA 0 s 0 s VA 0 s 0 s VA 0 s 0 s V 0 s 0 s TI05 and MI05 ycle Time (Two-Position) ycle Time (Modulating) uty ycle (Two-Position) uty ycle (Modulating) ull oad AMP raw Torque (in-lb) 0 VA VA VA V 675 9

10 0 opyright 05 wyer Instruments, Inc. Printed in U..A. 0/5 R# Rev. 4 W.. ANRON A IVIION O WYR INTRUMNT, IN. P.O. OX 373 MIHIGAN ITY, INIANA 46360, U..A. Phone: 9/ ax: 9/ info@dwyermail.com

W.E. ANDERSON. Series WE03 3-Piece Tri-Clamp Stainless Steel Ball Valve. Specifications - Installation and Operating Instructions.

W.E. ANDERSON. Series WE03 3-Piece Tri-Clamp Stainless Steel Ball Valve. Specifications - Installation and Operating Instructions. y wyer Series W03 3-Piece Tri-lamp all Valve Specifications - Installation and Operating Instructions ulletin V-W03 W03-H00 W03-A0-AA07 W03-T0-A W03-A0 W03-A0-AA06 The SRIS W03 incorporates a full port

More information

W.E. ANDERSON. Series WE04 2-Piece Flanged Stainless Steel Ball Valve. Specifications - Installation and Operating Instructions.

W.E. ANDERSON. Series WE04 2-Piece Flanged Stainless Steel Ball Valve. Specifications - Installation and Operating Instructions. y wyer Series W04 -Piece langed all Valve Specifications - Installation and Operating Instructions ulletin V-W04 W04-H00 W04-A0-NN09 W04-TI0-A W04-A0-AA03 W04-T0-A The SRIS W04 incorporates a full port

More information

W.E. ANDERSON. Series WE01 Two Way Stainless Steel Ball Valve. Specifications - Installation and Operating Instructions.

W.E. ANDERSON. Series WE01 Two Way Stainless Steel Ball Valve. Specifications - Installation and Operating Instructions. y wyer eries W0 Two Way all Valve pecifications Installation and Operating Instructions ulletin VW0 W0H00 W0A0AA05 W0TI0A W0A0 W0T0A The RI W0 incorporates a full port two piece ball valve for great flow

More information

W.E. ANDERSON. Series WE35 3-Way NPT Brass Ball Valve. Specifications - Installation and Operating Instructions. Bulletin V-WE35

W.E. ANDERSON. Series WE35 3-Way NPT Brass Ball Valve. Specifications - Installation and Operating Instructions. Bulletin V-WE35 y wyer Series W35 3Way NPT rass all Valve Specifications Installation and Operating Instructions ulletin VW35 W35H00T W35A0TAA0 W35T0T3A W35A0L W35A0T3NN05 The SRIS W35 incorporates a full port 3way brass

More information

Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual

Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual 1 Cover screws 9/64 Allen wrench. Terminal strip screws 1/8 wide flat head screw driver. Mounting pad screws 3/8 socket Cover

More information

Electric Actuator Installation, Operation & Maintenance Manual

Electric Actuator Installation, Operation & Maintenance Manual Electric Actuator Installation, Operation & Maintenance Manual For Use with: All Standard AC Voltage Models Additional supplements may be needed for selected optional equipment including, but not limited

More information

Electric Actuator Installation, Operation & Maintenance Manual

Electric Actuator Installation, Operation & Maintenance Manual ICI Indelac Controls, Inc. Electric Actuator Installation, Operation & Maintenance Manual 6810 Powerline dr.-florence, Ky. 41042 - Telephone 859-727-7890, Tool free 800-662-9424 Fax. 859-727-4070, e-mail:

More information

Spring Return and Double Acting Pneumatic Quarter- Turn Actuators For Output Torques to 13,444 lb.in.

Spring Return and Double Acting Pneumatic Quarter- Turn Actuators For Output Torques to 13,444 lb.in. Spring Return and ouble cting Pneumatic Quarter- Turn ctuators For Output Torques to 13,444 lb.in. Features and benefits ompact rack and pinion design utilizes the whole piston area to develop output torque.

More information

FEATURES PORT ARRANGEMENTS

FEATURES PORT ARRANGEMENTS PTP Series PV 3-way all Valve Valve Pressure / Temperature 250 PTP Series valves can be used for flow diverting, mixing, or on/off isolation. They replace a Tee + 2 valve linkage assembly at reduced cost

More information

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation 12 Series Linear Actuators Operation & Maintenance Manual, Analog Positioner Installation 6810 POWERLINE DR.-FLORENCE, KY. 41042 - TELEPHONE 859-727-7890, TOLL FREE 1-800-662-9424 FAX. 859-727-4070, E-MAIL:

More information

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company PNEUMATIC ACTUATOR SERIES 92/93 Rack & Pinion Double Acting & Spring Return The High Performance Company SERIES 92/93 Styling, strength, compactness, and simplicity of design have been combined to produce

More information

HQ Series ¼ Turn Electric Actuator

HQ Series ¼ Turn Electric Actuator HQ Series ¼ Turn Electric Actuator Models HQ004 and HQ006 Operation and Installation Manual HQ Series Operation and Installation Manual REV B 27-02-2012 1 Table of Contents: General 1.0 Actuator Mounting

More information

HIGH PRESSURE TRUNNION BALL VALVES TBV SERIES

HIGH PRESSURE TRUNNION BALL VALVES TBV SERIES HIGH PREURE TRUNNION BALL VALVE TBV ERIE TBV FEATURE On/Off-service ball valve with 2-way pattern Diverter, selector and on/off-service ball valve with 3-way pattern MAWP* 10,000 psi (689 bar) with PEEK

More information

HQ Series ¼ Turn Electric Actuator

HQ Series ¼ Turn Electric Actuator HQ Series ¼ Turn Electric Actuator Models HQ008 to HQ300 Operation and Installation Manual HQ Series Operation and Installation Manual 1 Table of Contents: General 1.0 Actuator Mounting 2.0 Power Requirements

More information

AE Installation Operation & Maintenance Instructions

AE Installation Operation & Maintenance Instructions AE-1400 Installation Operation & Maintenance Instructions IMPORTANT Please read the installation operation and maintenance instruction prior to using any Jomar Valve component. Failure to follow the instructions

More information

Air Actuated Stainless Ball Valves 2-Piece Stainless Steel, Full Port 1/4 to 2 NPT

Air Actuated Stainless Ball Valves 2-Piece Stainless Steel, Full Port 1/4 to 2 NPT ir ctuated Stainless all Valves 2-Piece Stainless Steel, ull Port 1/4 to 2 SRIS eatures Spring Return or ouble cting ctuators ull Port direct mount ISO5211 valve 316 stainless steel body, ball and stem

More information

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump igh Pressure oolant Valve eries Pa/ orresponding to high speed grinding and long drilling processes oolant valve for high pressure coolant liquid (up to Pa/) that is ideal for lubrication, dust blowing

More information

Electric Modulating Actuator Installation, Operation & Maintenance Manual

Electric Modulating Actuator Installation, Operation & Maintenance Manual Electric Modulating Actuator Installation, Operation & Maintenance Manual For Use with: All Modulating AC Voltage Models Additional supplements may be needed for selected optional equipment including,

More information

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual For Use with: SNS4, SNS6, SNS10 & SNS15 Models Additional supplements may be needed for

More information

Installation, Maintenance and Operation Manual

Installation, Maintenance and Operation Manual Installation, Maintenance and Operation Manual Radius, LLC 4922 Technical Drive Milford, MI 48381 Contents 1. Before operating actuator.. 3 2. About EW actuators 4 1) Internal & external component 2) Internal

More information

Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual

Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual Models EW-880, 1400, 2100, 3100, 4400, 7000, 9700, 13000, 17000, 26500 EW-IMO-04 Radius, LLC 4922 Technical

More information

12 Series Linear Electric Actuator Installation, Operation & Maintenance Manual

12 Series Linear Electric Actuator Installation, Operation & Maintenance Manual 12 Series Linear Electric Actuator Installation, Operation & Maintenance Manual TELEPHONE: +1-859-727-7890 TOLL FREE: +1-800-662-9424 FAX: +1-859-727-4070 E-MAIL: DVOGES@INDELAC.COM MROBINSON@INDELAC.COM

More information

AS-Interface Installation Manual. ASAHI / AMERICA, Inc. Thermoplastic Valves and Piping Systems

AS-Interface Installation Manual. ASAHI / AMERICA, Inc. Thermoplastic Valves and Piping Systems AS-Interface Installation Manual Page 1 of 9 Rev A April 16, 2003 ASAHI / AMERICA, Inc. Thermoplastic Valves and Piping Systems 35 GREEN STREET PO BOX 653 MALDEN, MA. 02148 AS-Interface Installation Manual

More information

PED 97/23/EC COMPLIANT. Full and Compact Height Nitrogen Gas Springs Series Full Height / Matches ISO Standards

PED 97/23/EC COMPLIANT. Full and Compact Height Nitrogen Gas Springs Series Full Height / Matches ISO Standards atalog No. 10108A Full and ompact Height 90.10 / 90.8 eries 90.10 eries Full Height / Matches IO tandards 90.8 eries ompact Height Alternative PED 97/23/E OMPIANT 2 Introduction The global leader in nitrogen

More information

PED 2014/68/EU COMPLIANT. Full and Compact Height Nitrogen Gas Springs Series Full Height / Matches ISO Standards

PED 2014/68/EU COMPLIANT. Full and Compact Height Nitrogen Gas Springs Series Full Height / Matches ISO Standards atalog No. 17102 Full and ompact Height 90.10 / 90.8 eries 90.10 eries Full Height / Matches IO tandards 90.8 eries ompact Height Alternative PED 14/68/EU OMPIANT Introduction The global leader in nitrogen

More information

CSSDR-1. C Series Carbon Steel Bar Stock Ball Valves 4.1

CSSDR-1. C Series Carbon Steel Bar Stock Ball Valves 4.1 Series arbon Steel ar Stock all Valves Lockout hole diameter is 8mm SSR-1 Reduced port NPT ends to NS 1.2.1 One piece body lowout-proof stem 2 p.s.i., W.O.G. omplies with N MR-13 N MR-175/SO 15156 4.1

More information

I&M UT Series (2003 Design)

I&M UT Series (2003 Design) I&M UT Series (2003 Design) 3170 Wasson Road Cincinnati, OH 45209 USA Phone 513-533-7340 ax 513-533-7343 E-Mail: marwin@richardsind.com www.marwinvalve.com Installation & Maintenance Instructions for Marwin

More information

brochure PN

brochure PN brochure PN-2013-01 www.bitorq.com/pneumatic.html Pneumatic Actuators PAGES 4-11 ON THE WEB AT BITORQ.COM/PNEUMATIC_PN.HTML COMPACT, RELIABLE DESIGN OPEN-CLOSED ADJUSTMENT STOPS DOUBLE ACTING AND SPRING

More information

Air Actuated Ball Valves 3-Way T-Port Stainless Steel, Full Bore 1/4 to 2 NPT

Air Actuated Ball Valves 3-Way T-Port Stainless Steel, Full Bore 1/4 to 2 NPT ir ctuated all Valves 3-Way T-Port Stainless Steel, ull ore 1/4 to 2 SRIS eatures ull Port 3-way T flow path irect mount valve with standard ISO5211 mount 316 stainless steel body, ball and stem ctuators

More information

Quick quarter-turn rotation. High cycle stem design. Integrated mounting pad for actuators. Compact assembly. Complete line of accessories.

Quick quarter-turn rotation. High cycle stem design. Integrated mounting pad for actuators. Compact assembly. Complete line of accessories. 36 Series Stainless Steel 2-way ull Port all Valve The 36 is a full port, 36 stainless steel, 3 piece ball valve. t is available with threaded ends (36N), socket weld ends (36S), or quick clamp ends with

More information

ESR: Spring Return Actuator Spring Return Rack & Pinion Pneumatic Actuator Aluminum Housing

ESR: Spring Return Actuator Spring Return Rack & Pinion Pneumatic Actuator Aluminum Housing SR: Spring Return Actuator Spring Return Rack & Pinion Pneumatic Actuator Aluminum Housing STANDARD SPIIATIONS General Series SR igure 7901/7951 Standard Working Temperature -22 to +212 Design Parameters

More information

CVS Rack and Pinion Pneumatic Actuator

CVS Rack and Pinion Pneumatic Actuator Instruction Manual CVS Rack and Pinion Pneumatic Actuator Introduction These instructions apply specifically to the CVS Rack and Pinion pneumatic actuator. This manual provides sizing, maintenance, operation,

More information

Pneumatic Actuators. 1. DIE CAST ALUMINUM END CAPS: standard polyester powder coated

Pneumatic Actuators. 1. DIE CAST ALUMINUM END CAPS: standard polyester powder coated 4 5 Pneumatic s 1 2 6 NOMINAL VALUES: Pressure rating max 115 PSI Temperature range: standard (-4 F;+185 F), high (-4 F;+302 F), low (-40 F;+185 F) Pre lubricated for life of actuator at assembly 100%

More information

3 million cycles. High Pressure Coolant Valve. SGH Series W (24 VDC) (With light/surge voltage suppressor: 0.58 W)

3 million cycles. High Pressure Coolant Valve. SGH Series W (24 VDC) (With light/surge voltage suppressor: 0.58 W) igh Pressure oolant Valve eries Pa/ orresponding to high speed grinding and long drilling processes oolant valve for high pressure coolant liquid (up to Pa/) that is ideal for lubrication, dust blowing

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual (I-TORK PDS Series Pneumatic Actuator) PDS-M0108/1010 74-6, Chun Ui-Dong, Won Mi-Gu, Bucheon, Kyoung Ki-Do, Korea Tel : 82-2-855-1365, 66 Fax : 82-2-855-1367 E-mail : roy75@i-tork.com

More information

Air Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 NPT

Air Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 NPT ir ctuated all Valves 3-Piece Stainless Steel, ull Port 1/4 to 3 SERIES eatures Spring Return or ouble cting ctuators ull Port direct mount ISO5211 valve Swing-out bolted body design for easy maintenance

More information

Matic TM. Data sheet Sheet No.: Rev. A EL-O-MATIC ACTUATORS WITH ASCO SOLENOID VALVES Date: November /2 NC 5/2

Matic TM. Data sheet Sheet No.: Rev. A EL-O-MATIC ACTUATORS WITH ASCO SOLENOID VALVES Date: November /2 NC 5/2 ata sheet Sheet No.:.06. Rev. -O-MTI TUTORS WITH SO SOLNOI VLVS ate: November 009 Selector plate for / - / function lectrical entry Pg 9 8 ir entry G/" Speed control (optional) 7 Speed control (optional)

More information

Instrument Ball Valves

Instrument Ball Valves www.swagelok.com Instrument all s 40 Series On-off, switching, and crossover flow paths Working pressures up to 3000 psig (206 bar) Temperatures from 50 to 150 (10 to 65 ) Low-temperature service option

More information

ANDCO Eagle Actuator Instruction Manual

ANDCO Eagle Actuator Instruction Manual ANDCO Actuators ANDCO Eagle Actuator Instruction Manual The information contained in this manual is essential to safe, successful, long term operation of your Andco Eagle Linear Actuator. Read and follow

More information

Ball Valves. Full Ported Very low pressure drop. Polyamide Thrust Bearings Low actuation torque and high

Ball Valves. Full Ported Very low pressure drop. Polyamide Thrust Bearings Low actuation torque and high Features and Advantages Introduction The Parker High Pressure all Valve Product Line serves in applications ranging from 3000 to 10,000 PI. Included in this section is the eries VAL, especially designed

More information

Quarter Turn Ball Valve Systems 2 Pcs Body Design with Threaded Ends

Quarter Turn Ball Valve Systems 2 Pcs Body Design with Threaded Ends 2 Pcs Body Design with Threaded Ends Features Modular Program ball valve system igh quality investment cast stainless steel body and ends 2 pcs body full bore design, 2 way Blow out proof stem Disc spring

More information

Quarter Master Series 94 Actuator

Quarter Master Series 94 Actuator Quarter Master Series 94 Actuator Installation, Operation and Maintenance Manual Assembly Series 94 Manual Rev V 9/5/13 Page 1 of 12 Table of Contents Series 94 Electric Actuator Introduction... 3 Description...

More information

SVDA & SVSR Series Pneumatic Actuators. Installation and Operation Manual

SVDA & SVSR Series Pneumatic Actuators. Installation and Operation Manual Installation and Operation Manual Introduction This instruction manual contains important information regarding the installation, operation, maintenance and storage for Southern Valve SVDA and SVSR Series

More information

Spring Return and Double Acting Pneumatic Quarter-turn Actuators Operations Manual

Spring Return and Double Acting Pneumatic Quarter-turn Actuators Operations Manual Spring Return and Double Acting Pneumatic Quarter-turn Actuators Operations Manual Table of Contents General..................... 1 Pneumatic Recommendations... 1 Construction................. 2 Disassembly

More information

INSTALLATION & MAINTENANCE MANUAL

INSTALLATION & MAINTENANCE MANUAL INSTALLATION & MAINTENANCE MANUAL 3-WAY/4-WAY/5-WAY MULTI-PORT BALL VALVES T TEFLON PARTS - 1. Seat x 5 pcs. 2. Joint Gasket x 5 pcs. 3. Retainer Seal x 5 pcs. 4. Thrust Washer x 1 pc. 5. O-Ring x 1 pc

More information

BALL VALVE SERIES Pneumatic actuator - El-O-Matic

BALL VALVE SERIES Pneumatic actuator - El-O-Matic C D E BALL VALVE - 390 SERIES Pneumatic actuator - El-O-Matic FIGURE: PD: Pneumatic actuator, double acting PE: Pneumatic actuator, spring return G F DIMENSIONS: (mm) Ø DN C PD PE PD D E F Kg PE D E G

More information

OPERATION AND MAINTENANCE INSTRUCTIONS

OPERATION AND MAINTENANCE INSTRUCTIONS OPERATION AND MAINTENANCE INSTRUCTIONS 334 SERIES THREE-PIECE BALL VALVES 1/4 to 2-1/2 Installation and Operation Always install your valve according to accepted industry standards and practices and operate

More information

Figure RP ACTUATORS PNEUMATIC RACK & PINION.

Figure RP ACTUATORS PNEUMATIC RACK & PINION. Figure RP ACTUATORS PNEUMATIC RACK & PINION www.fnw.com TORQUE RANGES The RP rack and pinion actuators are available with output torques ranging from 44 to 36,269 in-lbs depending on air supply pressure

More information

PARALLEL SLIDE GATE VALVE AND ACTUATOR INSTALLATION, OPERATIONS MAINTENANCE MANUAL

PARALLEL SLIDE GATE VALVE AND ACTUATOR INSTALLATION, OPERATIONS MAINTENANCE MANUAL Certified to O-9001 5904 Bingle oad Houston, X 77092 elephone: (713) 860-0400 ax: (713) 860-0499 ervice epartment mergency ager: 1-800-316-0649 VVCHOOG, C. G VV CO O, OO MC M age 1 of 54 able of Contents.

More information

Air Operated Stainless Steel 6000psi Ball Valve

Air Operated Stainless Steel 6000psi Ball Valve Type: PA2811 Actuator fitted via mounting kit Pneumatic Actuator features: Rack and pinion construction Hard anodised extruded aluminium body Epoxy coated cast aluminium end caps Pre-tensioned spring sets,

More information

High Pressure Ball Valves Series BVHP. General Description. Operating. Specifications. Features. Performance Curves

High Pressure Ball Valves Series BVHP. General Description. Operating. Specifications. Features. Performance Curves Technical Information igh Pressure all Valves eries VP General Description eries VP valves are used for shut-off applications and are rated at 414 ar (6000 PI). The wide variety of porting options plus

More information

Ball Valves with Pneumatic Actuator Screw Thread and Flange Connection, Welded Connection

Ball Valves with Pneumatic Actuator Screw Thread and Flange Connection, Welded Connection Ball Valves with Pneumatic Actuator crew Thread and Flange Connection, Welded Connection measuring monitoring analysing pmax. PN 64 tmax. +60 C Connections: crew thread G to G 4 Welded connection N 5 to

More information

INLINE supplies a range of pneumatic 1/4 turn, RACK and PINION TYPE rotary actuators, in double-acting and spring return versions.

INLINE supplies a range of pneumatic 1/4 turn, RACK and PINION TYPE rotary actuators, in double-acting and spring return versions. Note: The parts referred to by the numbers in parentheses are shown on page 3 of this instruction manual INLINE supplies a range of pneumatic / turn, RACK and PINION TYPE rotary actuators, in double-acting

More information

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS WITH HYDRAULIC CONTROL PACKAGE PART NUMBER: SE-023 REVISION:

More information

SERIES 90/91 R PNEUMATIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

SERIES 90/91 R PNEUMATIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company SERIES 90/91 R PNEUMATIC ACTUATOR OPERATION AND MAINTENANCE MANUAL The High Performance Company Table of Contents Sa f e t y Information - Definition o f Te r m s... 1 De s c r i p t i o n o f Op e r at

More information

High Performance Butterfly Valves 2 Way Way 2-20 Bray MK Series High Performance Butterfly Valves ANSI Class 150 and 300

High Performance Butterfly Valves 2 Way Way 2-20 Bray MK Series High Performance Butterfly Valves ANSI Class 150 and 300 ray MK Series High Performance utterfly Valves NSI lass 10 and 00 High Performance utterfly Valves 2 Way 2 20 Way 2 20 /2/1 The ray Mcannalok MK Series high performance butterfly valves set the quality

More information

Air Operated Stainless Steel V-Ball Control Ball Valve

Air Operated Stainless Steel V-Ball Control Ball Valve Type: PA2702V Type: PA2712V Type: PA2722V Pneumatic actuator direct mounted Actuator fitted via mounting kit Actuator fitted via stem extension Pneumatic Actuator features: Rack and pinion construction

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual HQ 005. ELECTRIC ACTUATORS QUARTER-TURN ELECTRIC ACTUATORS Installation, Operation and Maintenance Manual s Version Ver. 1 Revision Rev. 1 Document No. HKQI-611 Small & Compact Design High corrosion resistance

More information

TOP-QUALITY PNEUMATIC ACTUATOR

TOP-QUALITY PNEUMATIC ACTUATOR TOP-QUALITY PNEUMATIC ACTUATOR BS EN ISO 9001:2000 INTRODUCTION PDS series Pneumatic Actuators are designed using Scotch-Yoke technology from PDS 50 to the largest of PDS 200. Scotch-Yoke technology is

More information

RACK & PINION ACTUATORS 2R40 to 2R1750 Series Installation & Maintenance Manual

RACK & PINION ACTUATORS 2R40 to 2R1750 Series Installation & Maintenance Manual TRIAC 2R Series Actuators: Attention: Instructional videos on some of the information provided below can be found on our website (http://www.a-tcontrols.com/videos/). Description Section Installation of

More information

Air Actuated Ball Valves 2-Way, Lead Free Brass, Full Port 1/4 to 3 NPT

Air Actuated Ball Valves 2-Way, Lead Free Brass, Full Port 1/4 to 3 NPT Air Actuated Ball Valves 2-Way, Lead Free Brass, Full Port 1/4 to 3 NPT SERIES Features Spring Return or Double Acting Actuators Lead Free Brass Ball Valve with ISO5211 direct mounting Full port design

More information

Quarter Master Chief Series 92 Actuator

Quarter Master Chief Series 92 Actuator Quarter Master Chief Series 92 Actuator Installation, Operation and Maintenance Manual File: Series 92 O & M manual Rev. V 4/22/2013 Page 1 of 13 Table of Contents Series 92 Electric Actuator Introduction...

More information

HQ-006 ¼ Turn Actuator

HQ-006 ¼ Turn Actuator HQ-006 ¼ Turn Actuator Installation & Maintenance Manual HQ-006 I&M Manual HQ-402-0606 1 Table of Contents General 1.0 Actuator Mounting 2.0 External Construction 3.0 Standard Wiring Diagrams 4.0 Manual

More information

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

HIGH PRESSURE CONTROL VALVE PISTON BALANCED PISTON BALANCED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be

More information

A Type Double Acting Actuator Type: PA2911

A Type Double Acting Actuator Type: PA2911 Type: PA2911 Actuator fitted via mounting kit Pneumatic Actuator features: Rack and pinion construction Hard anodised extruded aluminium body Epoxy coated cast aluminium end caps Pre-tensioned spring sets,

More information

I & M UT Series (2003 Design)

I & M UT Series (2003 Design) I & UT Series (003 Design) 3170 Wasson Road Cincinnati, OH 4509 USA Phone 513-533-5600 Fax 513-871-0105 marwin@richardsind.com www.marwinvalve.com Installation & aintenance Instructions for arwin UT Series

More information

PSG. Installation and Operations Maintenance Manual. Parallel Side Gate Valve & Actuator

PSG. Installation and Operations Maintenance Manual. Parallel Side Gate Valve & Actuator G nstallation and Operations Maintenance Manual arallel ide Gate Valve & ctuator age 2 B O CO. OCO.... 4. O... 4. CVG O... 4 B. OO... 4 1. CO... 4 2. M OO.... 4 C. OO... 4. HM COC... 5 1. WG.... 5 2. O...

More information

APS SERIES. Air Pump Shut Off Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS

APS SERIES. Air Pump Shut Off Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS APS SERIES APS-DBV-4FP 334 Friendship Drive, Magnolia, TX 77355 Tel.: 8-59-7768 Fax: 8-59-749 www.hyvair.com A0SR Standard Features Indicator A position indicator

More information

ICI Indelac Controls, Inc. Installation, Operation & Maintenance Manual For Electric Spring Return Actuator

ICI Indelac Controls, Inc. Installation, Operation & Maintenance Manual For Electric Spring Return Actuator ICI Indelac Controls, Inc. Installation, Operation & Maintenance Manual For Electric Spring Return Actuator 6810 Powerline Dr. Florence, Ky. 41042 Telephone 859-727-7890, Tool free 800-662-9424, Fax. 859-727-7-4070,

More information

Evans SN Series. Evans. Sanitary & Vacuum Ball Valves

Evans SN Series. Evans. Sanitary & Vacuum Ball Valves SN Series Sanitary & Vacuum Ball Valves SN Series 1/2-4, DN/ISO 8 thru ISO 100 Sizes True Bore Design Cavity Free PTFE Seats Live Loaded Stem Seal ASME/BPE Compliant SF1 Standard Surface Finish The SN

More information

MT SERIES PNEUMATIC ROTARY ACTUATORS

MT SERIES PNEUMATIC ROTARY ACTUATORS MT SERIES PNEUMATIC ROTARY ACTUATORS Toll Free 1.888.842.9998 Fax 1.866.842.3144 6 FEATURES COMPACT DESIGN The MAX-AIR rack & pinion pneumatic actuator produces linear torque output in a compact design

More information

Actuated Valves PRICING

Actuated Valves PRICING Electric & Pneumatic Actuated Valves Actuated Valves PRICING Page Suitable for Oil-Free air handling to 5 psi, not for distribution of compressed air or gas Spears Manufacturing Company Due to Material

More information

Evans Ball Valves. Evans. High Purity 304 Stainless

Evans Ball Valves. Evans. High Purity 304 Stainless Ball Valves High Purity 304 Stainless SG Series 1/4-12 and 15A-300A s CFOS Cleaned and Bagged Integrated Valve Assemblies Standard Spool Assemblies & Custom Spool engths (Customer Specified in Feet) 100%

More information

Series 10 Actuator. Installation, Operation and Maintenance Manual

Series 10 Actuator. Installation, Operation and Maintenance Manual Series 10 Actuator Installation, Operation and Maintenance Manual File: series10.man Location: assembly/manual Rev.E 6/24/14 Page 1 of 8 Table of Contents Series 10 Electric Actuator Introduction... 3

More information

KENCO ENGINEERING COMPANY

KENCO ENGINEERING COMPANY KENCO ENGINEERING COMPANY P.O. BOX 470426 TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 www.kenco-eng.com e-mail: info@kenco-eng.com SERIES KTD THERMAL DIFFERENTIAL FLOW/LEVEL SWITCH INSTALLATION

More information

2 ½ 4 Deringer 40/50 Maintenance Instructions READ INSTRUCTIONS IN FULL BEFORE INSTALLATION. QUESTIONS? CALL M-F 8:00 AM 4:30 PM PST

2 ½ 4 Deringer 40/50 Maintenance Instructions READ INSTRUCTIONS IN FULL BEFORE INSTALLATION. QUESTIONS? CALL M-F 8:00 AM 4:30 PM PST 2 ½ 4 eringer 40/50 Maintenance Instructions RE INSTRUTIONS IN FULL EFORE INSTLLTION. QUESTIONS? LL 916-760-4524 M-F 8:00 M 4:30 PM PST t ackflow irect we are committed to making our products as easy to

More information

aero 2 -IOM aero 2 ACTUATOR - INSTALLATION, OPERATION & MAINTENANCE MANUAL

aero 2 -IOM aero 2 ACTUATOR - INSTALLATION, OPERATION & MAINTENANCE MANUAL Instruction DP00226 May 2015 IMPORTANT SAFETY WARNINGS A. Before carrying out any repair or maintenance on the actuator, make sure that the pressure supply lines and electrical connections have been safely

More information

Flow Line Controls. Installation & Operations Manual SERIES 20/21 Pneumatic Actuators

Flow Line Controls. Installation & Operations Manual SERIES 20/21 Pneumatic Actuators Flow Line Controls Installation & Operations Manual SERIES 20/21 Pneumatic Actuators Flow Line Controls, Inc. P.O. Box 677 Schriever, LA 70395 Phone: 985-414-6003 Toll Free 1-800-815-9226 Fax 985-414-6072

More information

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service Installation Instructions VA-908x Code No. LIT-12011566 Issued August 24, 2009 Applications The VA-908x Series Electric

More information

radius Series A pneumatic rack & pinion actuators

radius Series A pneumatic rack & pinion actuators radius Series A pneumatic rack & pinion actuators EVOLUTION IN ENGINEERING The Series A double acting and spring return pneumatic rack and pinion actuators from Radius offer uncompromising standards of

More information

radius Series A pneumatic rack & pinion actuators

radius Series A pneumatic rack & pinion actuators radius Series A pneumatic rack & pinion actuators EVOLUTION IN ENGINEERING Seals: Buna-N Nitrile is standard. Optional materials are available. The Series A double acting and valve and damper applications.

More information

Installation and Maintenance Instructions for Morin MRP Pneumatic Rack and Pinion Actuators

Installation and Maintenance Instructions for Morin MRP Pneumatic Rack and Pinion Actuators for Morin MRP Pneumatic Rack and Pinion Actuators Introduction The Morin MRP Pneumatic Actuator is a compact, rack & pinion design, conforming to Keystone standard or direct mount standards or EN ISO 5211

More information

DA/SR. Pneumatic Rotary Actuators FEATURES VALBIA ISO 9001 CERTIFIED

DA/SR. Pneumatic Rotary Actuators FEATURES VALBIA ISO 9001 CERTIFIED VALBIA ISO 9001 CERTIFIED FEATURES Twin Rack and Pinion Design Constant Torque Output Compact Design Balanced Internal Forces Robust Design For Long Life Extruded Aluminum Body Hard Coat Anodized Smooth

More information

E Series Electric Actuators

E Series Electric Actuators ENGINEERING MANUAL 13560 Larwin Circle, Santa Fe Springs, CA 90670 Phone: (562) 802-2255 (800) 783-7836 Fax: (562) 802-3114 Netsite: www.svf.net E-mail: Sales@SVF.net E Series Electric Actuators 1/4 3

More information

AV INSTALLATION, OPERATION & MAINTENANCE MANUAL

AV INSTALLATION, OPERATION & MAINTENANCE MANUAL Rack & Pinion Pneumatic Actuators AV INSTALLATION, OPERATION & MAINTENANCE MANUAL AVCS PO Box 68172 Minneapolis, MN 55418 TABLE OF CONTENTS CHAPTER 1: PRODUCT DESCRIPTION 3 CHAPTER 2: TECHNICAL FEATURES

More information

Catalog No. C Gestamp Specific Selected Products PED 2014/68/EU COMPLIANT

Catalog No. C Gestamp Specific Selected Products PED 2014/68/EU COMPLIANT atalog No. 15114 PED 2014/68/EU OMPIANT Introduction The global leader in nitrogen gas spring technology DADO produces top quality products at competitive prices and provides a superior level of customer

More information

BALL VALVE WITH ADA PNEUMATIC ACTUATOR

BALL VALVE WITH ADA PNEUMATIC ACTUATOR 702-703 BALL VALVE WITH ADA PNEUMATIC ACTUATOR DESCRIPTION The 702-703 ball valves are dedicated to the automatic shut off of industrial fluid s lines. It is a 3 pieces full valve with internal screws

More information

A comprehensive range of pneumatic actuators, providing compact, reliable and economical powered operation for all types of quarter-turn valves

A comprehensive range of pneumatic actuators, providing compact, reliable and economical powered operation for all types of quarter-turn valves KEYSTONE A comprehensive range of pneumatic actuators, providing compact, reliable and economical powered operation for all types of quarter-turn valves Features Direct mounting to all Keystone butterfly

More information

Marsh Instruments. Marshalltown Value Series Gauge. Specifications. X-Mas Tree Gauge. Specifications. belgas.net 1

Marsh Instruments. Marshalltown Value Series Gauge. Specifications. X-Mas Tree Gauge. Specifications. belgas.net 1 Marsh Instruments Marshalltown Value eries Gauge AME Grade B Extra avings with Quantity Pricing 4 tandard Mounting Options: LM, CB, Right & Left (1.5" Only) Marshalltown Value eries are the most economical,

More information

LLN Series Linear Actuator Installation, Operation & Maintenance Manual

LLN Series Linear Actuator Installation, Operation & Maintenance Manual ICI Indelac Controls, Inc. N Series inear Actuator Installation, Operation & Maintenance Manual 6810 Powerline Dr.-Florence, Ky. 41042 - Telephone 859-727-7890, Toll free 800-662-9424 Fax. 859-727-4070,

More information

Z-Tech Severe Chemical Service Valves We Put Control Where You Need It.

Z-Tech Severe Chemical Service Valves We Put Control Where You Need It. Z-Tech Severe Chemical Service Valves We Put Control Where You Need It. Z-Tech Series Valves TABLE OF CONTENTS Ball Valves ZT 4 Series: Three Piece Flanged Ball Valve... -3 Pneumatic Actuators and Accessories...

More information

A Zy-Tech Global Industries Product

A Zy-Tech Global Industries Product A Zy-Tech Global Industries Product Worm & evel Gear Operators Another quality product from Zy-Tech Global Industries, Inc. Zy-Gear gear operators are designed for long lasting dependable service in oil

More information

CLARK SOLUTIONS 8P Series Pneumatic Actuated Ball Valves 1/4 to 4 Brass & Stainless Steel, 2-way & 3-way configurations

CLARK SOLUTIONS 8P Series Pneumatic Actuated Ball Valves 1/4 to 4 Brass & Stainless Steel, 2-way & 3-way configurations CLARK SOLUTIONS 8P Series Pneumatic Actuated Ball Valves 1/4 to 4 Brass & Stainless Steel, 2-way & 3-way configurations www.clarksol.com SERIES 8P0O80/82/135/136 SERIES 8P0129/131(T,L) 80: Direct mount

More information

Type 2000 Transducer Product Instructions

Type 2000 Transducer Product Instructions Type 2000 Transducer Product Instructions The Type 2000 is an electro-pneumatic device that regulates an unregulated supply pressure down to an electronically-controlled output pressure. There are two

More information

Spring Return and Double Acting Pneumatic Quarter-Turn Actuators For Output Torques to 27,624 lb.in. INTRODUCTION

Spring Return and Double Acting Pneumatic Quarter-Turn Actuators For Output Torques to 27,624 lb.in. INTRODUCTION VLVS & CONTROLS KYSTON PNUMTIC CTUTOR Spring Return and ouble cting Pneumatic Quarter-Turn ctuators For Output Torques to 27,624 lb.in. INTROUCTION For remote control of any quarter-turn application, including

More information

MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody

MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody I INTRODUCTION These rugged, versatile, high performance, regular port, ball valves meet all requirements

More information

Flow-Alert Flow Switches (Micro Switch)

Flow-Alert Flow Switches (Micro Switch) Flow-Alert Flow witches (Micro witch) Automatically signals alarm if flow is too high or too low Automatically opens or closes electrical circuits Triggers warning lights, buzzers and other devices huts

More information

Ball Valves. ASME Class 150 to mm mm (¼" - 8") ISO 17292/ API 6D

Ball Valves. ASME Class 150 to mm mm (¼ - 8) ISO 17292/ API 6D Ball Valves SM Class 150 to 2500 8 mm - 200 mm (¼" - 8") ISO 17292/ PI 6D L&T Valves Limited is a wholly owned subsidiary of Larsen & Toubro. Backed by a fifty-year track-record of excellence and world-leading

More information

C Series Pneumatic Rack & Pinion Rotary Actuators

C Series Pneumatic Rack & Pinion Rotary Actuators Allied Flow Controls, Inc. C Series Pneumatic Rack & Pinion Rotary Actuators Spring Return & Double Acting Features and Benefits Torque Range at 0 Psig Air Pressure: Double Acting: -,00 lbf-in Spring Return:

More information

Charts for Solenoid Valve Selection

Charts for Solenoid Valve Selection harts for olenoid election 1. ir flow rate of each series (2-, 3-port) olenoid valve series 062 126 ir flow rate /min [ft. 3 /min.] (N) 200 300400 1000 2000 3000 10000 20000 170 [6.0] 370 [13.1] upply

More information