OWNER S MANUAL E N G L I S H BUILDING GATEWAYS AMR07Y UG-AMR07Y/E

Size: px
Start display at page:

Download "OWNER S MANUAL E N G L I S H BUILDING GATEWAYS AMR07Y UG-AMR07Y/E"

Transcription

1 E N G L I S H UG-AMR07Y/E OWNER S MANUAL BUILDING GATEWAYS AMR07Y Please read this installation manual carefully before installing your air conditioner. Please keep this manual in a safe place for future reference. This manual many be subject to change without notice for purpose of improvement.

2 CATALOGUE 1. Connection Illustration Functions Destription Application instances Charts for Network Variables...4

3 1 CONNECTION ILLUSTRATION 1-1 AMR07Y Terminals Illustration 1-2 System Connection Illustration USB Port: PC USB Port COM1/COM2: PC Serial Terminal COM: The Gateways AMR07Y Serial Terminal 1 1

4 2. FEATURES DESCRIPTION This unit shall be installed as a medium between in Building Management System (BMS) which provide with LonWorks interfaces, and Midea central A/C system, associating these two systems to realize the systems integration. BMS is allowed to access any online A/C in Midea central A/C system for information collection and operation control, after proper installation Midea A/C, the 3-Generation Central A/C Monitored Control System and this unit. 2-1 Information Collection This unit is provided a function that collecting information from Midea central A/C by BMS, which operation states' data of indoor units and outdoor units within A/C system could be obtained by modify the corresponding LonWorks network variables. Refer to Operation Instances for detail operation examples, and see Network Variables charts for specific information variables. 2-2 Operation Control The unit provides BMS control Midea central A/C, with six setting functions to control the indoor units in which of the system. Setting functions included Operation mode setting, Open time setting, Close time setting and Auxiliary function setting. By modify the corresponding LonWorks network variables to set the unit's operation status. Refer to Operation Instances for detail operation examples, and see Network Variables charts for specific information variables. Hardware Software PC Electric meter WHM The 3-generation network external assembly Uninterrupted power supply UPS Other Operation system Equipment specifications Recommendation CPU: Pentium 4, above 2G main frequency hard disk, not less than 40G; Intenal storage: More than 512M; Lenovo, Dell Communication terminal: Not less than 2 items of products RS-232 terminal, and 3 items of USB terminal. Functions: The meter can alter electric address as per to convention dynamic state, and can read the reading data from electric meter according to dynamic address input by main board. Includes: Installation manual,soft lock dog, and transition port Capacity: 200~250 W/20min; Voltage: As per practical operation; Control signal: Power cut signal. With 3-cord shielded twisted pair line WIN2000/WINXP The 3-generation moniter software Mircosoft SQLServer 2000 Personal edition (Personal Edition) Chint DTS634 or relevant model APC Su700 series Note Recommending to use XP system shall be installed Sp4 or above, otherwise SQL Server could not be installed properly. 2

5 3 OPERATION INSTANCES 3-1 Reading Operation Data from Indoor Unit: BMS read data from indoor unit which main unit address is 6, network address is 1, process as following: 1) Modify the network variable nvimainaddr=6, therefore, set the A/C main unit address as 6; 2) Modify the network variable nvimainaddr=1, therefore, set the A/C NET network address as 1; 3) Modify the network variable nvigetlasvalue= , convey the latest information of which set equipment to LonWorks. Needs to renew the system once only, the system return all information from the appointed A/C at a time, of which corresponding network variable would be refreshed automatically. 3-2 Setting Operation Modes for Indoor Unit BMS read data from indoor unit which main unit address is 8, network address is 2, process as following: 1) Modify the network variable nvimainaddr=8, therefore, set the A/C main unit address as 8; 2) Modify the network variable nvimainaddr=2, therefore, set the A/C NET network address as 2; 1) Modify the network variable nvisetworkmode= HVAC_COOL, therefore set the appointed equipment service at cooling mode. Enactments include: Operation mode setting, Air speed setting, Temperature setting, open time setting, close time setting and auxiliary function setting, each time with only one kind of enactments by Data set to control A/C equipment. Combination operate setting shall be set time after time. Readable variables and writable variables is individually in LonWorks network, thus the amendment of the network variable nvisetworkmode would not reflect at network variable nvoworkmode at once, unless the network variable nvoworkmode have been renew by BMS. 3-3 Reading Operation Data from Outdoor Unit BMS read data from indoor unit which main unit address is 9, network address is 16, process as following: 1.Modify the network variable nvimainaddr=9, therefore, set the A/C main unit address as 9; 2.Modify the network variable nvimainaddr=16, therefore, set the A/C NET network address as 16; 3.Modify the network variable nvigetlastvalue= , convey the latest information of which set equipment to LonWorks. Needs to renew the system once only, the system return all information from the appointed A/C at a time, of which corresponding network variable would be refreshed automatically. 3

6 This system adopts the manner of shared network variable to manage A/C system, which cannot access the appointed A/C within central A/C system, until the main unit address nvimainaddr and network address nvinetaddr are modified to the one that is intended to access, such main unit address variable is nvimainaddr, network address variable is nvinetaddr, refresh variable is nvigetlastvalue, and the rest parameters refer the following table. 4-1 Table of Operation Data Reading Table of Indoor Unit Network Variables Table 4.1 Model information Operation mode Mode locking state Indoor fan state Setting temperature Ts See annexed table for detail1 = HVAC_NUL = -1 Mode have not been set =HVAC_AUTO = 0 Auto mode =HVAC_COOL = 3 Cooling mode =HVAC_HEAT = 1 Heating mode =HVAC_DEHUMID = 14 Dehumidified mode =HVAC_FAN_ONLY = 9 Fan only mode =HVAC_OFF = 6 Off mode = HVAC_NUL = -1 Mode have not been locked =HVAC_AUTO = 0Lock on auto mode =HVAC_COOL = 3Lock on cooling mode =HVAC_HEAT = 1Lock on heating mode =HVAC_DEHUMID = 14 Lock on dehumidified =HVAC_FAN_ONLY = 9Lock on fan only =ST_LOW = 1 Low speed =ST_MED = 2 Medium speed =ST_HIGH = 3 High speed =ST_ON = 4 Auto 16~32 stand for 16~32 Setting temperature T1 Evaporator pipe temperature T2A Mid-part of evaporator pipe temperature T2B Condenser pipe temperature T3 Compressor current 0~200 stand for current 0A~200A Humidity 0~100 stand for relative humidity 0% 100% 4

7 4-1-1 Table of indoor unit network variables( Continued 4.1 table) Table: 4.2 Set on time Set off time 0~96 stand for no time fixed~24 hours timing 0~96 stand for no time fixed~24 hours timing Bhit15 Bit6 Outdoor unit states Oil return 1: On 0: Off Crankcase 1: On 0: Off Four-way valve Outside fan at low speed Outside fan at high speed Compressor Remote controller locked Integrated controller locked 00 Lock-on shut down or unlocking 01 Lock-on cooling 10 Lock-on heating 11 Lock-on fan only mode Auxiliary function states nvoasstfuntstats Water drainage pump Water added Humidifying Horizontal air supply Drying function Oxygen added Air renewal Ventilation Sway Auxiliary electrical heating Economic operation 5

8 4-1-1 Table of indoor unit network variables(continued 4.2 table) Table: 4.3 Other s Set 1 Water level detection Outdoor Refresh Alarm states Converter module Compressor overcurrent (4 times) Communication between main board & display screen Air speed detection out of control EEPROM error Zero-crossing detection error Malfunction in air discharge temperature sensor of T3, T4 or digital compressor. T2B Sensor T2A Sensor T1 Sensor Communication Phases' sequence error or default Other effective Set Unused Unused Unused Unused Unused Unused Protection states Compressor overcurrent Power supply over-under voltage Air exhaust low pressure Air exhaust high pressure Air exhaust temperature Compressor temperature Condensate high temperature Anti-cool air or defrost Evaporator temperature 6

9 ) Table of indoor unit network variable: (Continued 4.3 table) Table: 4.4 Error command Set 1 Network device alarm Electric Power Unit 0.1 MPa Target address nonentity Not be performed when command time-out Command limits performance Communication between in integrating monitor and PC (Gateways) Communication between in integrating monitor and function module. Communication betweenin integrating monitor and network interface. Communication between in network interface and main control board. 0Ffh stand for no effective data Annexed table 1 Model information of Indoor unit A/C models' information are composed by 2 bytes, which stand for A/C types and functions distinction. For each byte, please refer to the following table. Annexed table 1 The first byte Main model A/C Great type Auxiliary model A/C Small type 0001 Wall mounted type 0010 Floor type 0011 Embedded type 0100 Duct type 0101 Floor and ceiling type Auxiliary machine for A/C 1010 Digital mutil-connection 1100 Conversion 1110 Digital rotation Divide into 4 types 00~11 The second byte Alternate version Extended temperature setting Oxygen added function Refresh function Wind sway function Air exchange function Auxiliary electric heating Reserve Heating only/ Both cooling and heating 0 0 s t a n d f o r o r i g i n a l v e r s i o n 01~11stand for alternate version sequence 1 Yes(16 ~32 ) 0 No (17 ~30 ) 1 Yes 0 No 1 Yes 0 No 1 Yes 0 No 1 Yes 0 No 1 Yes 0 No Set 0 1 cool only 0 Both cooling and heating Table of indoor unit network variables For a whole A/C system share the network variable of BMS CCM07, thus a same network variable would be employed, represent for indoor unit and outdoor unit, which could be distinguished by model information. 7

10 etwork variabletable of conversion outdoor unit: Table: 4.5 Model information See annexed table 1 for detail Operation mode = HVAC_NUL = -1 Mode have not been set HVAC_COOL = 3 Cooling mode HVAC_HEAT = 1 Heating mode HVAC_OFF = 6 Off mode Mode locked state = HVAC_NUL = -1 Mode have not been locked HVAC_COOL = 3 Lock on cooling mode HVAC_HEAT = 1 Lock on heating mode Indoor fan state Outdoor temperature T4 Temperature at the inlet of outdoor condensate T3 Temperature at the inlet of outdoor condensate T6 Compressor 1 ventilated temperature Compressor 2 ventilated temperature Compressor 3 ventilated temperature =ST_LOW = 1 Low speed =ST_MED = 2 Medium speed =ST_HIGH = 3 High speed 0~200 stand for -20~180 0~200 stand for -20~180 0~200 stand for -20~180 Indoor unit qty. 0~250 stand for 0~250 items 8

11 etwork variabletable of conversion outdoor unit :(Continued 4.5 table) Table: 4.6 Compressor 1 current Compressor 2 current Compressor 3 current Converter compressor frequency Electrical expanding valve 1 opening angle Electrical expanding valve 2 opening angle States of outdoor unit solenoid valve 0~200 stand for current 0A~200A 0~200 stand for current 0A~200A 0~200 stand for current 0A~200A 0~250 stand for t0~250hz 00h~07Dh stand for close opening angle of ~1000 steps resolution is 8 steps 0FF stand for no this data. 00h~07Dh stand for close opening angle of ~1000 steps resolution is 8 steps 0FF stand for no this data. Unused, set to 0 Solenoid valve SV8 Solenoid valve Sv7 Solenoid valve Sv6 Solenoid valve Sv5 Solenoid valve Sv4 Spray cooling solenoid valve SV3 Auxiliary four-way valve ST2 Four-way valve ST1 Unused, set to 0 States of compressor and auxiliary functions Compressor 3 Compressor 2 Compressor 1 9

12 1) etwork variabletable of conversion outdoor unit: ( Continued 4.6 table) Table: 4.7 Other s (Set 1) Malfunction of outdoor unit qty. Increase Effect on main unit Malfunction of outdoor unit qty. Decrease Effect on main unit Network communication DSP communication Voltage Alarm states T6 Sensor Malfunction in air discharge temperature sensor of T3, T4 or digital compressor. Outdoor /indoor unit communication Phases' sequence error or default Outdoor unit communication Other (Set 1) Oil average Oil return Protection states Outdoor unit operation capability demand Unit 0.1 MPa Defrost Power supply over under-voltage Compressor current 3 Compressor current 2 Conversion mould protenction Condensate high temperature Air exhaust pipe temperature Compressor current 1 Low pressureair exhaust High pressureair exhaust Temperature for compressor upper enclosure 0Ffh stand for no effective data 10

13 2) Table of digital indoor unit network variables(continued 4.7 table) Table: 4.8 Model information See annexed table 1 fo detail Operation mode = HVAC_NUL = -1 Mode have not been set HVAC_COOL = 3 Cooling mode HVAC_HEAT = 1 Heating mode HVAC_OFF = 6 Off mode Mode locking state = HVAC_NUL = -1 Mode have not been locked HVAC_COOL = 3 Lock on cooling mode HVAC_HEAT = 1 Lock on heating mode Indoor fan state Outdoor temperature T4 Temperature at the inlet of outdoor condensate T3 Temperature at the inlet of outdoor condensate T6 Compressor 1 ventilated temperature Compressor 2 ventilated temperature Compressor 3 ventilated temperature Indoor unit qty. =ST_LOW = 1 Low speed =ST_MED = 2 Medium speed =ST_HIGH = 3 High speed 0~200 stand for -20~180 0~200 stand for -20~180 0~200 stand for -20~180 0~250 stand for 0~250 unit 11

14 2) Table of digital outdoor network variable: ( ) Table: 4.9 Compressor 1 current Compressor 2 current Compressor 3 current Converter compressor frequency Electrical expanding valve 1 opening angle Electrical expanding valve 2 opening angle States of Outdoor unit solenoid valve States of Compressor and auxiliary functions Vo1 0~200 stand for current 0A~200A 0~200 stand for current 0A~200A 0~200 stand for current 0A~200A 00~100 stand for the adjustment of 0%~100% 00h~07Dh stand for close opening angle of ~1000 steps resolution is 8 steps 0FF stand for no this data. 00h~07Dh stand for close opening angle of ~1000 steps resolution is 8 steps 0FF stand for no this data. Unused set 0 Solenoid valve SV8 Solenoid valve Sv7 Solenoid valve Sv6 Solenoid valve Sv5 Solenoid valve Sv4 Spray cooling solenoid valve SV3 Auxiliary four-way valve ST2 Four-way valve ST1 Unused set 0 Compressor 3 Compressor 2 Compressor 1 12

15 Table of digital indoor unit network variables(continued 4.9 table) No Maning Type Name Despriction Other s Table: 4.10 Malfunction of outdoor unit qty. Increase Effect on main unit Malfunction of outdoor unit qty. Decrease Effect on main unit Malfunction of network communication Alarm states T5 Tempeerature sensor T3B Tempeerature sensor T4 Tempeerature sensor T3A Tempeerature sensor Indoor units communication Phases' sequence error or default Outdoor units communication Other Oil average Oil return Defrost Protection states Compressor current 2 Condensate high pressure Air exhaust pipe temperature Compressor current 21 Air exhaust low pressor Outdoor unit operation capability demand Unit 1 PMa Air exhaust high pressor Temperature for compressor upper enclosure 0~250 stand for 0~250 Pma 13

16 Table of Outdoor Water Unit network Variables Table:4.11 No Model information See annexed table 2 for detail Operation mode = HVAC_NUL = -1 Mode have not been set = 20 Pump mode = HVAC_COOL = 3 Cooling mode = HVAC_HEAT = 1Heating mode = HVAC_OFF = 6 Off mode Mode locking state = HVAC_NUL = -1Mode have not been set = 20 Pump mode = HVAC_COOL = 3 Cooling mode = HVAC_HEAT = 1Heating mode = HVAC_OFF = 6 Off mode Indoor fan state Setting temperature Ts = ST_LOW = 1 Low speed = ST_MED = 2 Medium speed = ST_HIGH = 3 High speed Setting temperature T1 Temperature at the inlet of outdoor condensate T3 Plate exchange outlet temperature TW Total water outlet temperature AW nvozcstemp Plate exchanger temperature TB nvobhtemp 0~240 stand for-20~100 Indoor unit Qty. 0~250 stand for0~250 items 14

17 3) Table of Outdoor water unit network variable (Continued 4.11 table) Table: Compressor 1 current SNVT_amp nvocpr1current 0~200 stand for current 0A~200A 13 Compressor 2 current SNVT_amp nvocpr2current 0~200 stand for current 0A~200A 14 Compressor 3 current SNVT_amp nvocpr3current 0~200 stand for current 0A~200A 15 Adjust digital compressor SNVT_lev_cont nvocprvol 0~250 stand for 0~250Hz 16 Electrical expanding valve 1 opening angle SNVT_lev_cont nvovalve1 00h~07Dh stand for close opening angle of ~1000 steps resolution is 8 steps 0FF stand for no this data. 17 Electrical expanding valve 2 opening angle SNVT_lev_cont nvovalve2 00h~07Dh stand for close opening angle of ~1000 steps resolution is 8 steps 0FF stand for no this data. Bhit15 Bit8 Unused set 0 Bit7 Bit6 18 States of Outdoor SNVT_state (bit0-bit15) unit solenoid valve nvooutdevstats Bit5 Bit4 Bit3 Bit2 Bit1 Four-way valve B ST2 Bit0 Four-way valve A ST1 Bhit15 Bit8 Unused set 0 Bit7 19 States of Compressor and auxiliary functions SNVT_state (bit0-bit15) nvoasstfuntstats Bit6 Bit5 Bit4 Auxiliary electric heating Water pump Bit3 Bit2 Compress 3 Bit1 Compress 2 Bit0 Compress 1 15

18 3) Table of Outdoor Water Unit network Variables(Continued 4.12 table) Table 4.13 No Maning Type Name Despriction Other s Malfunction of outdoor unit qty. Increase Effect on main unit Malfunction of outdoor unit qty. Decrease Effect on main unit Malfunction of network communication Alarm states T5 Tempeerature sensor T3B Tempeerature sensor T4 Tempeerature sensor T3A Tempeerature sensor Indoor units communication Phases' sequence error or default Outdoor units communication Other effective Set Oil average Oil return Defrost Protection states Compressor current 2 Condensate high pressure Air exhaust pipe temperature Compressor current 21 Air exhaust low pressor Outdoor unit operation capability demand Unit 1 PMa Air exhaust high pressor Temperature for compressor upper enclosure 0~250 stand for 0~250 Pma 16

19 Annexed table 2: Outdoor model inforation 1) A/C models' information are composed by 2 bytes, which stand for A/C types and functions distinction. For each byte, please refer to the following table. Annexed table 2 The first byte Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0 Partition cords for outdoor unit 1111B 1111B Three phases option 1 Three phases 0 Single phase Main model A/C great type 000 Fix-rate 001 Conversion 010 Digital 011 Water unit Conservesion The second byte Horsepower of outdoor unit stand for 1 250MPa 2) 00H stand for unknown model. 4-2 Table of Operation Status Setting Set ting the main unit address Setting network address (Integrating controller No. ) Setting operation mode Setting indoor fan Setting temperature Ts Setting On time Setting Off time Setting auxiliary function Indoor unit address 0~63, Outdoor unit address 0~31 Indoor integrating controller address 0~15 Outdoor integrating controller address 16~31 = HVAC_NUL = -1 Mode have not been set =HVAC_AUTO = 0 Auto mode =HVAC_COOL = 3 Cooling mode =HVAC_HEAT = 1Heating mode =HVAC_DEHUMID = 14Dehumidified mode =HVAC_FAN_ONLY = 9Fan only mode =HVAC_OFF = 6Off mode =ST_LOW = 1 Low speed =ST_MED = 2 Medium speed =ST_HIGH = 3 High speed =ST_ON = 4 Auto 16~32 stand for 16~32 The other datas would not change the original setting. 0~96 stand for without time fixed~24 hours time fixed OFFh stand for no effective data 0~96 stand for without time fixed~24 hour time fixed OFFh stand for no effective data Bhit15 Bit4 Refresh Sway Auxiliary electrical heating Economic operation Note:LonWorks is the registered trademarks have been registered by Echelon Corporation in United State and other countries. 17

20 DE - COMMISSIONING DISMANTLING & DISPOSAL This product contains refrigerant under pressure, rotating parts, and electrical connections which may be a danger and cause injury! All work must only be carried out by competent persons using suitable protective clothing and safety precautions. Read the Manual Risk of electric shock Unit is remotely controlled and may start without warning 1. Isolate all sources of electrical supply to the unit including any control system supplies switched by the unit. Ensure that all points of electrical and gas isolation are secured in the OFF position. The supply cables and gas pipework may then be disconnected and removed. For points of connection refer to unit installation instructions. 2. Remove all refrigerant from each system of the unit into a suitable container using a refrigerant reclaim or recovery unit. This refrigerant may then be re-used, if appropriate, or returned to the manufacturer for disposal.under No circumstances should refrigerant be vented to atmosphere. Where appropriate, drain the refrigerant oil from each system into a suitable container and dispose of according to local laws and regulations governing disposal of oily wastes. 3. Packaged unit can generally be removed in one piece after disconnection as above. Any fixing down bolts should be removed and then unit lifted from position using the points provided and equipment of adequate lifting capacity. Reference MUST be made to the unit installation instructions for unit weight and correct methods of lifting. Note that any residual or spilt refrigerant oil should be mopped up and disposed of as described above. 4. After removal from position the unit parts may be disposed of according to local laws and regulations. UG-AMR07Y/E ENGLISH

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi 1 TABLE OF CONTENTS TABLE OF CONTENTS... 2 IMPORTANT NOTE... 3 FAULT FINDING AND DIAGNOSTICS... 3 ABBREVIATIONS... 3 PCB S... 4 OUTDOOR MAIN PCB... 4 INDOOR PCB...

More information

Air Conditioner. Installation manual. Wired remote controller MWR-WE11N

Air Conditioner. Installation manual. Wired remote controller MWR-WE11N Air Conditioner Installation manual Wired remote controller MWR-WE11N Thank you for purchasing this Samsung Product. Before operating this unit, please read this installation manual carefully and retain

More information

Engineering Data Book

Engineering Data Book 40VMA Outside Air Processing Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

Engineering Data Book

Engineering Data Book 40VMM Medium Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

Engineering Data Book

Engineering Data Book 40VMH High Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

Digital-Control and Programmable DC Power Supply Models: , , , & User Manual

Digital-Control and Programmable DC Power Supply Models: , , , & User Manual Digital-Control and Programmable DC Power Supply Models: 72-2535, 72-2540, 72-2545, 72-2550 & 72-10480 User Manual Page 19/05/16 V1.0 Safety Symbols This chapter contains important safety instructions

More information

Service Manual. 9. Maintenance. 9.1 Precautions before Maintenance. discharge resistance or plug of soldering iron. Installation and Maintenance

Service Manual. 9. Maintenance. 9.1 Precautions before Maintenance. discharge resistance or plug of soldering iron. Installation and Maintenance 9. Maintenance 9.1 Precautions before Maintenance Service Manual pacitor after power off. - discharge resistance or plug of soldering iron A B A B - nance safely. 40 9.2 Error Code List O. 1 2 3 4 5 6

More information

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw Air-to-Water Reverse Cycle Heat Pumps VLH 504 to 1204 126 to 294 kw 133 to 307 kw Technical Brochure TM VLH-N.3GB Date : June 2005 Supersedes : TM VLH-N.2GB/07.04 Specifications Advantages Range extension

More information

FULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014

FULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014 FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS COMMERCIAL AIR CONDITIONERS SDV4 2014 AIR CONDITIONING 1 WELCOME TO THE WORLD OF SINCLAIR AIR CONDITIONERS Company operation

More information

USERS MANUAL MCD REMOTE OPERATOR

USERS MANUAL MCD REMOTE OPERATOR USERS MANUAL MCD REMOTE OPERATOR Order Code: 175G9004, 175G3061 Contents Contents Introduction...2 Important User Information...2 General Description...2 Symbols Used in this Manual...2 Installation...3

More information

PART7. Trouble Shooting

PART7. Trouble Shooting PART7. Trouble Shooting 1. Indoor Unit Error Display Display E0 E1 E2 E3 E5 LED STATUS EEPROM parameter error Indoor unit and outdoor unit communication protection Zero-crossing signal error Indoor fan

More information

troubleshooting Outdoor Unit: KSIE009-H221-O, KSIE012-H220-O, KSIE018-H220-O KSIE024-H220-O, KSIR036-H218, KSIR048-H218

troubleshooting Outdoor Unit: KSIE009-H221-O, KSIE012-H220-O, KSIE018-H220-O KSIE024-H220-O, KSIR036-H218, KSIR048-H218 troubleshooting Table of Contents 1. Troubleshooting Model Numbers: Indoor Unit: KDIR09-H2, KTIR09-H2, KUIR09-H2 KDIR12-H2; KTIR12-H2, KUIR12-H2 KDIR18-H2, KTIR18-H2, KUIR18-H2 KDIR24-H2, KTIR24-H2, KUIR24-H2

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS 50FP-1SB 50FP034, 038, 044, 048, 054, 064, 074 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE FACTORY-INSTALLED OPTIONAL ELECTRIC HEAT

More information

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16 User Manual CLA-VAL Europe www.cla-val.ch cla-val@cla-val.ch 1 - LIN072UE - 04/16 Table of Contents 1 Introduction... 3 1.1 Precautions Before Starting... 3 1.2 Troubleshooting... 3 1.3 General Disclaimer...

More information

Parts Lists. Forward Series. Rev. Feb. 2017

Parts Lists. Forward Series. Rev. Feb. 2017 s HSU09VHJ(DB)-G / HSU09VHJ(DB)-W HSU12VHJ(DB)-G / HSU12VHJ(DB)-W HSU18VHJ(DB)-G / HSU18VHJ(DB)-W HSU24VHJ(DB)-G / HSU24VHJ(DB)-W 1800 Valley Road Wayne, NJ 07470 Tel +973.617.1800 www.haier.com - Edition

More information

Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions

Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions SCH2 & SCA2 High Temperature Compressors 35-240 Horsepower 1. Introduction This series of semi-hermetic compact screw compressors

More information

BRAVER UPS. (Uninterruptible Power System) User s Manual

BRAVER UPS. (Uninterruptible Power System) User s Manual BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.

More information

Fuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House

Fuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House Fuel Cell Lab Manual Non Conventional Energy Systems Facility Boiler House Department of Mechanical Engineering IIT Kanpur System Description The Nexa system provides up to 1200 watts of unregulated DC

More information

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING 199 RE ER RS SO AIR COOLED HEAT PUMP LIQUID CHILLERS 19,1 261,0 kw COOLING 23,7 333,0 kw HEATING R410A PLATE RCGROUP SpA 19632013 fiftycoolyears 200 VERSIONS: (R410A) Cooling capacity 19,2 261,0 kw Heating

More information

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

HYDROCIAT LW R134a. Water cooled chillers USE RANGE Screw compressors CIAT direct expansion shell and tubes evaporator equipment (High Power System) Cooling or heating Heat recovery ENVIRONMENTALLY HFC R134a PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling

More information

PRELIMINARY UNIT OPERATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento/Xarios/Zephyr - Unit operation Road only /Rev- #1/15

PRELIMINARY UNIT OPERATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento/Xarios/Zephyr - Unit operation Road only /Rev- #1/15 UNIT OPERATION Carrier Transicold Europe 03/09/07 Viento/Xarios/Zephyr - Unit operation Road only /Rev- #1/15 UNIT OPERATION Table of content Introduction...3 Operation principle...4 Cab command description...5

More information

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1 INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: Dec., 2015 Version: 1.1 2 3 What s in the Box CONTENT 2 Screws & Anchors 2 Screwdriver 4 Diode Contents What s in the Box...2 Optional accessories...4

More information

Air-Cooled Liquid Chiller with integrated hydraulic module

Air-Cooled Liquid Chiller with integrated hydraulic module Air-Cooled Liquid Chiller with integrated hydraulic module Cooling only: CGAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800 - 900-925 Reversible: CXAN 200-250 - 300-400 - 450-490 - 500-600 - 700-800

More information

COMMISSIONING Tick the tests carried out by attendee.

COMMISSIONING Tick the tests carried out by attendee. COMMISSIONING Model SN= Software version= Registration of A/C service station calculation on www.brainbee.com/ (reserved area) Registration code= Software available by Clima Solution Software version =

More information

3KW Off-grid Solar Power System LFP Battery

3KW Off-grid Solar Power System LFP Battery 3KW Off-grid Solar Power System LFP Battery 1 CATALOGUE 1. S u m m a r y 3 2. T e c h n i c a l p a r a m e t e r 4 3. D i s p l a y a n d f u n c t i o n i n s t r u c t i o n 5 4. S e q u e n c e o f

More information

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h Comfort air conditioning unit with highly efficient regenerative heat storage packages 68 10 01 - simplified illustration Automatically selects the most economical operating mode! 64 and 68 AIR OLUME FLOW:

More information

LIGHT COMMERCIAL. Troublesooting

LIGHT COMMERCIAL. Troublesooting LIGHT COMMERCIAL Troublesooting 2. 2.1 Display board 2.1.1 Icon explanation on indoor display board (Super slim cassette 24K). 2.1.2 Icon explanation on indoor display board (Compact cassette 12K, 18K).

More information

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh)

Product Data. Features/Benefits. WEATHERMASTER 36S Water Control Induction Air Terminals to cfm (1770 to 8900 Btuh) Product Data WEATHERMASTER 36S Water Control Induction Air Terminals 19.4 to 131.9 cfm (1770 to 8900 Btuh) Induction air terminals offer: Heating and cooling operation 2-pipe or 4-pipe system options Automatic

More information

Landmark Rooftop Packaged Units

Landmark Rooftop Packaged Units Landmark Rooftop Packaged Units Engineered for superior performance and reliability Exclusively distributed by AUS - 13 23 50 www.lennoxaus.com.au NZ - 0800 653 330 www.lennoxnz.co.nz 1 Landmark Rooftop

More information

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment Screw compressors CIAT shell and tubes direct expansion evaporator (High Power System) equipment Cooling capacity: 370 to 1 170 kw Heating capacity: 500 to 1 400 kw Heating Cooling Heat recovery Use The

More information

KSID MINI Split DC Inverter QUICK CONNECT Air Conditioner TROUBLESHOOTING KSID016-H215Q. Model Numbers:

KSID MINI Split DC Inverter QUICK CONNECT Air Conditioner TROUBLESHOOTING KSID016-H215Q. Model Numbers: KSID MINI Split DC Inverter QUICK CONNECT Air Conditioner TROUBLESHOOTING Model Numbers: KSID012-H115Q KSID022-H215Q KSID016-H215Q WARNING Installation MUST conform with local building codes or, in the

More information

FT-10 Network Digital I/O Module Kits and

FT-10 Network Digital I/O Module Kits and Instruction Sheet 10-2004 FT-10 Network Digital I/O Module Kits 541 0771 and 541 0772 PURPOSE OF KIT The Digital I/O Module (DIM) makes provisions for a group of relay contact outputs and discrete inputs

More information

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA Inventory Safety and General Information bu001c This unit is intended for indoor use only. Do not operate this unit in direct sunlight,

More information

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS 50FN-1SB 50FNX,FNY078,088,104 SINGLE-PACKAGE COOLING UNITS CONSTANT/VARIABLE AIR VOLUME PRODUCT INTEGRATED CONTROLS CARRIER COMFORT NETWORK COMPATIBLE WITH INTEGRAL ECONOMIZER AND HIGH-CAPACITY MODULATING

More information

Ventilation in balance

Ventilation in balance Ventilation in balance AIRLINQ - DIGITAL BMS PARAMETERS FOR BACNET TM /IP. BACNET TM MS/TP BASIC INFORMATION The present document is only valid for air handling units with firmware version 6. or newer.

More information

9. Maintenance. 9.1 Precautions before Maintenance. Service Manual. electrolytic capacitor after power off. maintenance safely.

9. Maintenance. 9.1 Precautions before Maintenance. Service Manual. electrolytic capacitor after power off. maintenance safely. 9. Maintenance 9.1 Precautions before Maintenance electrolytic capacitor after power off. A B A B maintenance safely. 50 9.2 Error Code List Unit o. ame Display 8 nixie 0.5s) Operation Indicator Cool Indicator

More information

TECHNICAL HANDBOOK. for MULTISPLIT NETWORK SYSTEMS OR GROUP CONTROL

TECHNICAL HANDBOOK. for MULTISPLIT NETWORK SYSTEMS OR GROUP CONTROL TECHNICAL HANDBOOK for MULTISPLIT NETWORK SYSTEMS OR GROUP CONTROL DESCRIPTION * Compatible with IMPACT E, IMAGE E and IMAGE 600² E systems * Configurable as either group control or multisplit * Single

More information

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw TWA 212-1102 S/K/P Incorporating R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw The complete solution to all your cooling needs TWA 212-1102 S/K/P Index

More information

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8 Contents : 1. INTRODUCTION...1 2. IMPORTANT SAFETY INSTRUCTIONS...2 3. SYSTEM DESCRIPTION...4 3.1 Front Panel...4 4. CONNECTION AND OPERATION...6 5. TROUBLESHOOTING...8 6. MAINTENANCE...9 6.1 Operation...9

More information

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS INSTRUCTION MANUAL TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS September 2000 TOWER UPS DISTRIBUTION (PTY) LTD 1 1. INTRODUCTION T A B L E O F C O N T E N T S 1.1 General Description... 3 1.2 Features...

More information

TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel

TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel 18/10 AISI 304 both in- and outside. All the internal corners

More information

Ventilation in balance

Ventilation in balance Ventilation in balance AIRLINQ - DIGITAL BMS PARAMETERS FOR MODBUS RTU RS485 BASIC INFORMATION The present document is only valid for air handling units with firmware version 6. or newer. The firmware

More information

User s Manual. Wind/Solar Hybrid Controller. Please Read This User Manual Carefully Prior to Installation and Operation of This Product V1.

User s Manual. Wind/Solar Hybrid Controller. Please Read This User Manual Carefully Prior to Installation and Operation of This Product V1. User s Manual Wind/Solar Hybrid Controller Please Read This Carefully Prior to Installation and Operation of This Product. 2014 V1.0 Notices 1) Battery reverse connection is forbidden. 2) Battery virtual

More information

D M S 760 C01 A A 1 1

D M S 760 C01 A A 1 1 CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................

More information

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to. Installation and Operation of This Product.

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to. Installation and Operation of This Product. User s Manual Wind/Solar Hybrid Street Light Controller Please Read This Carefully Prior to Installation and Operation of This Product. 2012 Version: 1.0 1. Product Introduction The wind/solar hybrid street

More information

XS400 Load Bank. Read all instructions before using the load bank. Contents

XS400 Load Bank. Read all instructions before using the load bank. Contents Read all instructions before using the load bank Contents 1) Components... 3 Total Assembly... 3 2) Specifications... 4 3) Receiving... 4 4) Safety... 5 a) Grounding cam... 6 b) Power connections... 6

More information

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons Product Catalog NQ Series Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons Page Intentionally Blank Contents Standard Features...1 Available Options...3 Oversized Pumps... 3 High Flow Unit

More information

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.

How to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1. Thermo-cooler Series HRGC Specifications HRGC//5 Cooling method Refrigerant Control method Ambient temperature/humidity Circulating fluid Note ) Temperature range setting Note ) C Cooling capacity Note

More information

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75. Chiller AQL/ to 75 Air Cooled Water Chillers Only and Heat Pump Engineering Data Manual.0 to 75.8 kw 39.9 to 77.2 kw Outstanding Strength Points R410A Refrigerant. New simpler refrigerant circuit layout.

More information

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD. Technical Support Division 2012.10 1 1. External appearance 2. Nomenclature 3. Specifications 4. Dimensions 5. Service space 6. Piping diagram 7. Wiring diagram 8. Capacity tables 9. Electric characteristics

More information

WG5Kxxx Modular DC-converter system

WG5Kxxx Modular DC-converter system Short description WG5Kxxx Modular DC-converter system General characteristics The modular DC converter system is useful for the DC coupling of various electrical components (sources, sinks, storages) with

More information

The AIRSTAGE J-II Series adopts the best technology. and was designed with the greatest care to provide not

The AIRSTAGE J-II Series adopts the best technology. and was designed with the greatest care to provide not The AIRSTAGE J-II Series adopts the best technology and was designed with the greatest care to provide not only energy savings and comfort but also ease of design, installation, and maintenance. Fujitsu

More information

User s Manual Wind/Solar Hybrid Controller

User s Manual Wind/Solar Hybrid Controller User s Manual Wind/Solar Hybrid Controller Please Read This User Manual Carefully Prior to Installation and Operation of This Product. 2012 V1.0 Notices 1) Battery reverse-connection is forbidden. 2) Battery

More information

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105 TECHNICAL CATALOGUE WPHA Cooling only WPHBA Heat pump Models 091, 121, 141, 171, 201, 251, 351, 401, 501, 701, 751, 1001, 1201 Cooling capacities from 2,4 kw to 41 kw Heating capacities from 2,8 kw to

More information

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS NB 0811 - NB 1511 NB 0831 - NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS LEN.MAN.UPS.069 Rev.2.00/2002 CONTENTS Safety Instructions 1 Introduction 3 2.1 FEATURE 3 2.2 UPS modules 4 How the UPS works 5 3.1

More information

Product Catalog TSE Series Scroll Central Chillers

Product Catalog TSE Series Scroll Central Chillers Product Catalog TSE Series Scroll Central Chillers Contents Features...1 Hot Gas Bypass Valve... 2 Rotary Non-Fused Disconnect Switch... 2 Integral Reservoir and Pumping System... 3 Remote Condenser Coil

More information

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC APPLICATION GUIDE Simplicity LINC GATEWAY OVERVIEW The Simplicity LINC Gateway operates as a Modbus Client providing an interface between a MS/TP control system and devices that communicate using the Modbus

More information

PSU EN54-4 Power Supplies

PSU EN54-4 Power Supplies PSU EN54-4 Power Supplies Ordering: Models, Sales Order Parts: PSU MXP-549 : 1.5A PSE in 7Ah enclosure MXP-550 : 3.0A PSE in 17/18Ah enclosure MXP-550D : 3.0A PSE in 25Ah enclosure MXP-551 : 5.0A PSE in

More information

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit ASYA24LCC ASYA24LCC ASYA24LCC Outdoor unit AOYR24LCC AOYR24LCD AOYR24LCL CONTENTS SPECIFICATIONS..................1 DIMENSIONS.....................

More information

Product Catalog TSE Series Scroll Central Chillers

Product Catalog TSE Series Scroll Central Chillers Product Catalog TSE Series Scroll Central Chillers Contents Features...1 Available Options...3 Hot Gas Bypass Valve... 3 Rotary Non-Fused Disconnect Switch... 3 Integral Reservoir and Pumping System...

More information

INSTRUCTION & INSTALLATION

INSTRUCTION & INSTALLATION INSTRUCTION & INSTALLATION MANUAL MODELS: CCL-eHOME T1C16 CCL-eHOME T1C32 CCL-eHOME T2C16 CCL-eHOME T2C32 WALLBOX ehome SERIES WALLBOX ehome Instruction and Installation manual This document is copyrighted,

More information

Unitary Air Conditioner Indoor Unit Service Manual R22/R410A,60/50HZ (GC I)

Unitary Air Conditioner Indoor Unit Service Manual R22/R410A,60/50HZ (GC I) R22/R410A,60/50HZ (GC201208-I) CONTENTS PRODUCT...2 1 MODELS LIST... 2 1.1 Air Handler...2 1.2 Fan Coil...2 1.3 Floor Ceiling...3 2 NOMENCLATURE... 3 3 FUNCTION... 4 4 PRODUCT DATA... 4 4.1 Product Data

More information

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before

More information

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU18RLF ASU24RLF AOU18RLXFW AOU24RLXFW R410A CONTENTS 1. DESCRIPTION OF EACH CONTROL OPERATION

More information

HAIRF UPS. X5 Series KVA

HAIRF UPS.   X5 Series KVA HAIRF UPS www.hairf.com.cn X5 Series 10-200KVA Company Profile Hairf is an international leading supplier of critical power supply units and refrigerating systems for equipment rooms. Main products of

More information

VTZ variable speed Reciprocating compressors

VTZ variable speed Reciprocating compressors MAKING MODERN LIVING POSSIBLE Application guidelines VTZ variable speed Reciprocating compressors R404A, R507, R407C, R134a www.danfoss.com CONTENT VARIABLE SPEED COMPRESSORS... 4 Speed control...4 Advantages

More information

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS

GR4GN Series TECHNICAL SPECIFICATIONS. Single Packaged Gas/Electric Units. GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS GR4GN Series Single Packaged Gas/Electric Units GR4GN 10.1 EER Commercial System 7½ and 10 Ton Units The GR4GN is designed specifically for retrofit applications and compatibility

More information

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software User Manual Thank you for purchasing the Defender 650/1200/1600. It is designed to provide safe and reliable power protection to your precious electronics equipment. Before you start using the product,

More information

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

User Manual Back-UPS BX650CI-MS 230 Vac with AVR User Manual Back-UPS BX650CI-MS 230 Vac with AVR Overview Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage. Read the Safety

More information

UMXCA/UMXCBA ECVA/ECVBA

UMXCA/UMXCBA ECVA/ECVBA OUTDOOR UNITS Models: 801.1 1001.1 1201.1 1501.1 1602.2 2002.2 2402.2 3002.2 3502.2 4002.2 4502.2 Cooling Capacities: from 25,9 kw to 134,7 kw Heating Capacities: from 27,3 kw to 142,4 kw INDOOR UNITS

More information

AHN 064 to 304 EHN/CHN 064 to 304

AHN 064 to 304 EHN/CHN 064 to 304 u Horizontal Packaged and Split Air Conditioners AHN 64 to 34 EHN/CHN 64 to 34 6. to 29.2 kw 6.4 to 29.4 kw Engineering Data Manual EDM AECHN-A.1GB Date : June 28 Supersedes : None Technical Description

More information

Innovair VRF Full DC Inverter Technology (50/60 Hz)

Innovair VRF Full DC Inverter Technology (50/60 Hz) Innovair VRF Full DC Inverter Technology (/60 Hz) R-410 Contents 1 2 3 4 5 6 7 8 9 10 11 13 Innovair Full DC Inverter Technology High efficiency and more energy saving Two-stage oil separation control

More information

High Static Pressure Duct Fan Coil Unit

High Static Pressure Duct Fan Coil Unit MCAC-KTSM-2012-03 High static pressure ducted FCU High Static Pressure Duct Fan Coil Unit 1. Introduction... 2 2. Nomenclature... 2 3. Product Schedule... 3 4. External Appearance... 3 5. Features... 4

More information

System Monitoring SCHOOLMETERBOX AU

System Monitoring SCHOOLMETERBOX AU System Monitoring SCHOOLMETERBOX AU Installation Guide SMETER-IEN084710 98-00013210 Version 1.0 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes on this Manual..............................

More information

TANZANIA BUREAU OF STANDARDS

TANZANIA BUREAU OF STANDARDS EDC 5 (5235) P3 Mini-Grid Systems DRAFT TANZANIA STANDARD (Draft for comments only) Part 2: Application of Inverters TANZANIA BUREAU OF STANDARDS TBS 2017 First Edition 2017 T able of content 1 2 3 4 5

More information

Condensate Drain Valve AK 45. Original Installation Instructions English

Condensate Drain Valve AK 45. Original Installation Instructions English Condensate Drain Valve AK 45 EN English Original Installation Instructions 810467-03 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 Danger...4 Attention...4 PED (Pressure

More information

CEILING CONCEALED LOSSNAY LGH-25RX3

CEILING CONCEALED LOSSNAY LGH-25RX3 VOLUME SIGN Control signal Heat recovery system Heat recovery module material Cladding Heat insulating material Motor Blower Filter material Operating environment (Supply air) Functions Weight Serial single

More information

The Daikin Driver. This document relates to Daikin driver version 1.0 and 1.1

The Daikin Driver. This document relates to Daikin driver version 1.0 and 1.1 The Daikin Driver The Daikin driver interfaces to a Daikin air-conditioning system. Compatible with the Daikin VRV, HRV and SkyAir ranges. Available for Commander and ObSys. This document relates to Daikin

More information

INTECH Micro 2300-RTD6

INTECH Micro 2300-RTD6 INTECH Micro 2300-RTD6 6 Channel RTD Input Station Overview. The Intech Micro 2300 Series is a system of modular I/O Remote Stations, that add an even lower cost option to Intech s already extensive intelligent

More information

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount Important Safety Messages Read the instructions carefully to become familiar with the equipment before attempting to install, operate,

More information

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual On Line UPS LUC 1000E / LUC 2000E / LUC 3000E User Manual Save This Manual Please read this manual carefully prior to storage, installation, wiring, operation and maintenance of the UPS. This manual contains

More information

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02 1/16 Operators and Maintenance Manual Display EEM MOT 01 FE02.02 Rev. 01 December 2017 2/16 Table of Contents Introduction... 3 1. General information... 3 2. Handling in transport and storage... 4 3.

More information

CP900EPFCLCD User s Manual K

CP900EPFCLCD User s Manual K CP900EPFCLCD User s Manual K01-0000190-00 IMPORTANT SAFETY INSTRUCTIONS This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation

More information

/ LOSSNAY / LGH-RS2-E2

/ LOSSNAY / LGH-RS2-E2 2 Indoor units / / LGH-RS2-E2 unit CONTENTS LGH-RS2-E2. LGH-5RS2-E2 48 2. LGH-25RS2-E2 49. LGH-5RS2-E2 44 4. LGH-5RS2-E2 44 5. LGH-8RS2-E2 442 6. LGH-RS2-E2 7. LGH-5RS2-E2 8. LGH-2RS2-E2 44 444 445 9.

More information

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE Indoor unit AGYF09LAC AGYFLAC AGYFLAC AGYFLAC Outdoor unit AOYV09LAC AOYVLAC AOYVLAC AOYVLAL CONTENTS SPECIFICATIONS..................... DIMENSIONS.........................

More information

1. Unit selection (based on cooling load)

1. Unit selection (based on cooling load) . Outdoor unit 1. Unit selection (based on cooling load) 11. Indoor unit selection Select the indoor unit based upon cooling load and unit capacity. (The indoor unit capacity should larger than the load.)

More information

LCU DX Efficient cooling with no loss of space

LCU DX Efficient cooling with no loss of space LCU DX Efficient cooling with no loss of space 2 Cooling for network and server enclosures Space-saving installation of the internal unit between the 482.6 mm (19 ) level and side panel Optimum support

More information

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw Air-to-Water Reverse Cycle Heat Pumps SLH 1202 to 3804 With Screw Compressors 261 to 775 kw 287 to 853 kw Technical Brochure TM SLH-A.2GB Date : November 2004 Supersedes : TM SLH-A.1GB/05.04 Design Features

More information

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS P6SD Series The P6SD Series packaged units are high efficiency self contained cooling units that can be installed on a roof or on a slab. The convertible unit design makes installations

More information

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13. MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. - 1 - Table of Contents 1. SALIENT FEATURES...3 2.. PRODUCT INSTALLATION & PRECAUTIONS...3 2.1. PRODUCT INSTALLATION &

More information

An ISO 9001:2008 Registered Company

An ISO 9001:2008 Registered Company An ISO 9001:2008 Registered Company Introduction Engine Monitor System 2009-2018 Ford E Series (EMS501-D) 2008-2010 Ford F250-550 6.2L, 6.8L (EMS506-D) 2011-2016 Ford F250-550 6.2L, 6.8L (EMS507-D) 2017

More information

CEILING CONCEALED LOSSNAY LGH-80RX3

CEILING CONCEALED LOSSNAY LGH-80RX3 LGH-8RX3 VOLUME SIGN Control signal Heat recovery system Heat recovery module material Cladding Heat insulating material Motor Blower Filter material Operating environment (Supply air) Functions Weight

More information

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE

EXPERT 2V4SA. Temperature Controller. User s manual CLEAN MODE COMPENSATION HUMIDITY OUTSIDE TEMPERATURE CLEAN MODE Temperature Controller User s manual CURRENT CONDITIONS ROOM TEMPERATURE PROBE TEMPERATURE OUTSIDE TEMPERATURE RELATIVE HUMIDITY STATIC PRESSURE TIME / DATE SETTINGS SET POINT / CURVE MINIMUM

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Compact Wall Mounted Wall Mounted / Floor Compact Cassette / Slim Duct INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Compact Wall Mounted Wall Mounted / Floor Compact Cassette / Slim Duct INVERTER MULTI SPLIT TYPE ROOM AIR CONDITIONER Compact Wall Mounted Wall Mounted / Floor Compact Cassette / Slim Duct INVERTER MULTI SERVICE INSTRUCTION Models Indoor unit Outdoor unit ASU7RLF ASU9RLF ASU2RLF ASU8RLF

More information

Application Engineering Europe

Application Engineering Europe Date of last update: Feb-12 Ref: D7.8.4/0112-0212/E Application Engineering Europe CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS 1/17 1 Introduction CoreSense is an ingredient brand name for

More information

PCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS

PCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS PCT plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS Ver. DESCRIPTION The PCT plus is a pressure controller for refrigeration plants that require control in their suction and discharge stages. With

More information

The Multivariable Air Flow Meter

The Multivariable Air Flow Meter The Multivariable Air Flow Meter Model MVC10A/MVC10F OVERVIEW The Multivariable Mass Flow Meter model MVC10A/ MVC10F, a compact has all function necessary to measure nitrogen (N 2 ) gas, carbon dioxcide

More information

INSTALLATION USER MANUAL

INSTALLATION USER MANUAL INSTALLATION & USER MANUAL DYNAMIC LOAD MANAGEMENT -PREMIUM- This document is copyrighted, 2016 by Circontrol, S.A. All rights are reserved. Circontrol, S.A. reserves the right to make improvements to

More information

Number 1 in efficiency

Number 1 in efficiency PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter The

More information