FD Frame. Breaking capacities. Protection

Size: px
Start display at page:

Download "FD Frame. Breaking capacities. Protection"

Transcription

1 FD Frame Breaking capacities 2, 3 and types Single pole types Icu 0/415V C in k eff. Type FD FD C Protection Trip Unit Rated Current () E LTM S N LTMD H GTM L 1 1 Mag Break TM Icu 2/2V C in k eff. N H Trip Unit Rated Current () LTM LTM Line thermal magnetic protection LTMD Selective thermal magnetic protection GTM Generator thermal magnetic protection Mag Break TM Magnetic Only protection Y Non utomatic or switch (not mentioned in tables) FD (2,3 & ) FD (2,3 & ) Number of poles/ protected poles (trips) S, S, S,,L S,,L S,,L S,,L S,,L S,,L S,,L S,,L S,,L,L,L,L,L,L FD (single pole) 1 Number of poles/ protected poles (trips) 2 pole 2 trips 3 trips 3 trips 4 trips N S,,L,L S,,L,L,L 1 pole 1 trip 3.5 trips (N=%) (2),L O1 O2 O3 O4 O5 O6 O7 O8 uxiliary contact left mounted (NO or NC) uxiliary contact right mounted (NO or NC) Bell larm trip unit (NO or NC) Bell larm mechanism (CO) (1) Shunt or Undervoltage release Operators Rotary Handle Electrical Operator RCD, side or bottom mounted (Insert indicates Bell alarm contact mounting) Plug in system (1) ccessories (1) Not applicable for the FDC types. (2) Rated current.4

2 FD/ Complete Circuit Breaker Line Thermal Magnetic LTM (fixed settings) 18 k FDC 18 k FDC In () trips FDC35TE0EF FDC35TE0EF FDC35TE0EF FDC35TE0EF FDC35TE0EF FDC35TE0EF FDC35TE0EF FDC35TE0GF FDC35TEGF FDC35TE1GF FDC35TEGF FDC35TE0ED FDC35TE0ED FDC35TE0ED FDC35TE0ED FDC35TE0ED FDC35TE0ED FDC35TE0ED FDC35TE0GD FDC35TEGD FDC35TE1GD FDC35TEGD trips (1) FDC45TC0EF FDC45TC0EF FDC45TC0EF FDC45TC0EF FDC45TC0EF FDC45TC0EF FDC45TC0EF FDC45TC0GF FDC45TCGF FDC45TC1GF FDC45TCGF One code covers a standard, fixed front connection breaker with: * Fixation hardware. 3 trips 4 trips (1) FDC45TE0ED FDC45TE0ED FDC45TE0ED FDC45TE0ED FDC45TE0ED FDC45TE0ED FDC45TE0ED FDC45TE0GD FDC45TEGD FDC45TE1GD FDC45TEGD * DINRail mounting kit * Breaker finishing covers * Fixation hardware FD frame k FDE 1 3 trips 4 trips (1) FDE36TF0EF FDE36TF0EF FDE36TF0EF FDE36TF0EF FDE36TF0EF FDE36TF0EF FDE36TF0EF FDE36TF0GF FDE36TFGF FDE35TF1GF FDE35TFGF FDE46TF0EF FDE46TF0EF FDE46TF0EF FDE46TF0EF FDE46TF0EF FDE46TF0EF FDE46TF0EF FDE46TF0GF FDE46TFGF FDE45TF1GF FDE45TFGF * DINRail mounting kit * Breaker finishing covers * Fixation hardware Line Thermal Magnetic LTM (adjustable thermals) k FDE 1 3 trips 4 trips (1) FDE35TC0EF FDE35TC0EF FDE35TC0EF FDE35TC0EF FDE35TC0EF FDE35TC0EF FDE35TC0EF FDE35TC0GF FDE35TCGF FDE35TC1GF FDE35TCGF FDE45TC0EF FDE45TC0EF FDE45TC0EF FDE45TC0EF FDE45TC0EF FDE45TC0EF FDE45TC0EF FDE45TC0GF FDE45TCGF FDE45TC1GF FDE45TCGF * Fixation hardware k FDE 1 3 trips 4 trips (1) FDE35TE0ED FDE35TE0ED FDE35TE0ED FDE35TE0ED FDE35TE0ED FDE35TE0ED FDE35TE0ED FDE35TE0GD FDE35TEGD FDE35TE1GD FDE35TEGD FDE45TE0ED FDE45TE0ED FDE45TE0ED FDE45TE0ED FDE45TE0ED FDE45TE0ED FDE45TE0ED FDE45TE0GD FDE45TEGD FDE45TE1GD FDE45TEGD * DINRail mounting kit * Breaker finishing covers * Fixation hardware (1) Neutral on the left. If neutral on the right is needed, please contact us..5

3 FD/ Complete Circuit Breaker Selective Thermal Magnetic LTMD (settable thermals) 3 trips 4 trips (1) 36 k FDS k 2V k k In () In () 1 FDS35TD0ED FDS35TD0ED FDS35TD0ED FDS35TD0ED FDS35TD0ED FDS35TD0ED FDS35TD0ED FDS35TD0GD FDS35TDGD FDS35TD1GD FDS35TDGD 2 pole 2 trips 66TD0ED 66TD0ED 66TD0ED 66TD0ED 66TD0ED 66TD0ED 66TD0ED 66TD0GD 66TDGD 66TD1GD 66TDGD 13TF0EF 13TF0EF 13TF0EF 13TF0EF 13TF0EF 13TF0EF 13TF0EF 13TF0GF 13TFGF 13TF1GF 13TFGF 36TD0ED 36TD0ED 36TD0ED 36TD0ED 36TD0ED 36TD0ED 36TD0ED 36TD0GD 36TDGD 36TD1GD 36TDGD FDS45TD0ED FDS45TD0ED FDS45TD0ED FDS45TD0ED FDS45TD0ED FDS45TD0ED FDS45TD0ED FDS45TD0GD FDS45TDGD FDS45TD1GD FDS45TDGD 436TD0ED 436TD0ED 436TD0ED 436TD0ED 436TD0ED 436TD0ED 436TD0ED 436TD0GD 436TDGD 436TD1GD 436TDGD TF0EF 13TF0EF 13TF0EF 13TF0EF 13TF0EF 13TF0EF 13TF0EF 13TF0GF 13TFGF 13TF1GF 13TFGF 46TD0ED 46TD0ED 46TD0ED 46TD0ED 46TD0ED 46TD0ED 46TD0ED 46TD0GD 46TDGD 46TD1GD 46TDGD One code covers: standard fixed front connection breaker + DINRail mounting kit + Toggle elongator + Line Thermal Magnetic LTM (fixed settings) 1 pole 1 trip Selective Thermal Magnetic LTMD (settable thermals) V k 1 pole 1 trip TD0ED 456TD0GD 456TDGD 456TD1GD 456TDGD 3 trips 3 trips (1) 4 trips (1) 3.5 trips (N=%) (1) k 1 36TD0ED 36TD0ED 36TD0ED 36TD0ED 36TD0ED 36TD0ED 36TD0ED 36TD0GD 36TDGD 36TD1GD 36TDGD TD0ED 436TD0ED 436TD0ED 436TD0ED 436TD0ED 436TD0ED 436TD0ED 436TD0GD 436TDGD 436TD1GD 436TDGD TD0ED 46TD0ED 46TD0ED 46TD0ED 46TD0ED 46TD0ED 46TD0ED 46TD0GD 46TDGD 46TD1GD 46TDGD TD0ED 456TD0GD 456TDGD 456TD1GD 456TDGD k FDL 1 FDL36TD0ED FDL36TD0ED FDL36TD0ED FDL36TD0ED FDL36TD0ED FDL36TD0GD FDL36TDGD FDL36TD1GD FDL36TDGD FDL436TD0ED FDL436TD0ED FDL436TD0ED FDL436TD0ED FDL436TD0ED FDL436TD0GD FDL436TDGD FDL436TD1GD FDL436TDGD FDL46TD0ED FDL46TD0ED FDL46TD0ED FDL46TD0ED FDL46TD0ED FDL46TD0GD FDL46TDGD FDL46TD1GD FDL46TDGD One code covers: standard fixed front connection breaker + DINRail mounting kit + Toggle elongator + (1) Neutral on the left. If neutral on the right is needed, please contact us. FDL456TD0ED FDL456TD0GD FDL456TDGD FDL456TD1GD FDL456TDGD

4 FD/ Complete Circuit Breaker Generator Thermal Magnetic GTM (settable thermals) 3 trips 3 trips (1) 4 trips (1) 3.5 trips (N=%) (1) In () k 1 36TG0ED 36TG0ED 36TG0ED 36TG0ED 36TG0ED 36TG0GD 36TGGD 36TG1GD 36TGGD TG0ED 436TG0ED 436TG0ED 436TG0ED 436TG0ED 436TG0GD 436TGGD 436TG1GD 436TGGD TG0ED 46TG0ED 46TG0ED 46TG0ED 46TG0ED 46TG0GD 46TGGD 46TG1GD 46TGGD TG0ED 456TG0GD 456TGGD 456TG1GD 456TGGD k 1 36TG0ED 36TG0ED 36TG0ED 36TG0ED 36TG0ED 36TG0GD 36TGGD 36TG1GD 36TGGD TG0ED 436TG0ED 436TG0ED 436TG0ED 436TG0ED 436TG0GD 436TGGD 436TG1GD 436TGGD TG0ED 46TG0ED 46TG0ED 46TG0ED 46TG0ED 46TG0GD 46TGGD 46TG1GD 46TGGD TG0ED 456TG0GD 456TGGD 456TG1GD 456TGGD FD frame One code covers: standard fixed front connection breaker + DINRail mounting kit + Toggle elongator + Motor Protection (Mag BreakTM) Magnetic Only Breakers k In () MC003ED 36MC007ED 36MC012ED 36MC0ED 36MC0ED 36MC0ED 36MC0GD 36MCGD (1) 436MC003ED 436MC007ED 436MC012ED 436MC0ED 436MC0ED 436MC0ED 436MC0GD 436MCGD k MC003ED 36MC007ED 36MC012ED 36MC0ED 36MC0ED 36MC0ED 36MC0GD 36MCGD MC003ED 436MC007ED 436MC012ED 436MC0ED 436MC0ED 436MC0ED 436MC0GD 436MCGD k FDL FDL36MC0ED FDL36MC0ED FDL36MC0ED FDL36MC0GD FDL36MCGD FDL436MC0ED FDL436MC0ED FDL436MC0ED FDL436MC0GD FDL436MCGD One code covers: standard fixed front connection breaker + DINRail mounting kit + Toggle elongator + + IPXXB covers (Finger protection on connection clamps) Complete Nonutomatic Circuit Breaker (Switch) In () FDY6D0ED FDY6DGD (1) FDY6D0ED FDY6DGD FDY One code covers: standard fixed front connection breaker + DINRail mounting kit + Toggle elongator + (1) Neutral on the left. If neutral on the right is needed, please contact us..7

5 FD Internal accessories Contacts Normally open Normally closed Changeover ux. switch right mounted ux. switch left mounted Bell alarm trip unit Bell alarm RCD device Bell alarm mechanism (1) FS10R FS10L FBT10 FBT FS01R FS01L FBT01 FBT FDBM11 48 Releases Electrical Operators 12V DC 24V C/DC 48V C/DC 60V C/DC 110/1V C/DC 2/2V C 2 V DC 0/4V C 2/2V C FD Operators 24V C/DC 48V C/DC 60V C/DC 110V C/DC 2/2V C/DC 0/4V C FSHTB FSHTD FSHTF FSHTH FSHTJ FSHTN FSHTU FDEMFD FDEMFF FDEMFH FDEMFJ FDEMFN FDEMF8 Shunt FUVRD FUVRF FUVRH FUVRJ FUVRN FUVRU Undervoltage Delayed undervoltage FUVDN 4858 Keylock for operator Ronis (2) Keylock for operator Profalux (2) FD1BRE FD1BPE Rotary Handles Direct on device Rotary handle for use through door or cover plate (3) Panel or door mounted Grey Red Grey + auxiliary contacts 2xNO (4) Red + auxiliary contacts 2xNO (4) RF RFV RC RCV RY RYV Grey (max. 3 mm) Red (max. 3 mm) Grey + auxiliary contacts 2xNO (4) Red + auxiliary contacts 2xNO (4) ccessories RD RDV RZ RZV (a) Flex operator adaptor push to trip, set of 2 pcs. (a) Extension shaft kit (max. 600 mm) (b) Sidebyside installation adapter kit (c) FT RE R Only for use with panel or door mounted type Only for use with panel or door mounted type Not for use with panel or door mounted type (c) (b) (e) Ronis keylock 1104B nr. BC 1027 (2) Ronis keylock 1104B nr. BC 1053 (2) Ronis keylock 1104B nr. BC 29 (2) Ronis keylock 1104B nr. BC 2911 (2) Ronis keylock 1104B nr. BC 2936 (2) Ronis keylock 1104B nr. BC 29 (2) Ronis lock with random key (2) Profalux lock with random key (2) (e) F1BR1 F1BR2 F1BR3 F1BR4 F1BR5 F1BR6 F1BRH F1BPH RCD Side Mounted (5) FD Residual Current Devices Standard Voltage 2/4V C (a) Voltage 0/690V C (a) FDQDS3M FDQDS3H FDQDS4M FDQDS4H (a) One code covers an RCD with: DINRail mounting kit & Multidirectional supply kit Side connected only Voltage 2/4V C (b) FDQDI3M FDQDI4M (b) One code covers an RCD with: DINRail mounting kit and Interconnection kit. RCD Bottom Mounted (5) (below trip unit area) Voltage 2/4V C Voltage 0/690V C FDQDB3M FDQDB3H Normally open FDQDB4M FDQDB4H Normally closed Bell larm RCD device FBT FBT One code covers an RCD with: Sealable connection cover (cutout adaptor FDUF) (1) Not for FDC and FDE types (2) Key included (3) dd door flange FDFH to allow use of the door interlock options (4) On request 1xNO/1xNC is available. (5) Not possible on FDC and FDE types.8

6 Main system Complete FD Plugin System (1) Complete set for breaker Fixed part for breaker Mobile part for breaker FDDDF3 FDDFF3 FDDMP FDDDF4 FDDFF4 FDDMP Fixed part for breaker & RCD Mobile part for breaker & RCD FDDFQ3 FDDMP FDDFQ4 FDDMP Fixed Mobile Complete set: Fixed and mobile part with connection and fixation hardware Fixed part: Fixed base with connection and fixation and hardware Mobile part: Mechanism trip device, terminal shields and set of 3 or plugs uxiliary disconnects Secondary wiring (2) Insertion prevention kit Complete set 8 pole Fixed part 8 pole Mobile part 8 pole Plug and socket 10 pole Insertion prevention kit (of.wrong rating) FPFM FPF8 FPM8 FPPS FPIP FD frame Extenders (a) (b) (c) FD Connections: Optional (4) Standard flat type (a) Heightened type (b) Twisted 90 (c) FDBES3 FDBEH3 FDBE FDBES4 FDBEH4 FDBE Spreader flat Pole spacing 35 mm FDBSS FDBSS External Box Clamps Cable Cu/l 95 mm 2(3) FDTC13 43 FDTC Rear Connections Set (2 short, 1 long) Set (2 short, 2 long) FDBRC FDBRC Spares, set of 2 short types Spares, set of 2 long types FDBRCS2 FDBRCL FD Installation ccessories Terminal shields (with finishing covers) Long, set of 2 pcs. FDJL FDJL Short, set of 2 pcs. FDJS FDJS4 49 Specific to connection area Phase separators, set of 12 pcs. FDJP 4957 Backplate set of 2 pcs. (3 or ) FDJB 4945 Finger protection IPXXB (set of 12 pcs) (5) FDJK 4069 Covers Cutout adaptor, Breaker + Trip unit FDUF3 48 FDUF4 48 Cutout filler for cover plate (64 mm), length of 1.2 m FBF (1) Plugin system max. 1. (2) Only necessary when internal accessories or an electrical operator are used. (3) External box clamps are always delivered with standard extender (4) Set for equipping the line OR load side of breaker. (5) Supplied with mag. break types..9

7 FD Installation ccessories (continued) Padlocking devices for toggle operator (1) Padlocking removable FD1PR 4879 Padlocking fixed FD1PF 4878 Circuit indication/coding Set of blank labels FC 4821 Heightning set for ElfaPlus MCB's Length = (18 modules of 18 mm) 354 mm FDKE Door Flanges Breaker front face and RCD Rotary handle (through cover plate model) FDFF3 FDFH FDFF Electrical operator FDFE 4310 Spare parts DINrail adaptor kit (2) FDKD FDKD Finishing covers, set of 2 pcs. (2) Spare toggle (set of 5 pieces) FDU3 FDUT FDU (1) Padlocks not included (2) Supplied with breakers, not with FDC and FDE types.10

FE Frame. Breaking capacities. Protection

FE Frame. Breaking capacities. Protection FE Frame Breaking capacities Icu 0/415V C in k eff. Type FE FE2 V 36 N H L 1 1 LTM Line thermal magnetic protection LTMD Selective thermal magnetic protection GTM Generator thermal magnetic protection

More information

FD frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FD63 FD160. Trip Unit. Rated Current (A) FD63 (2,3 & 4 pole)

FD frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FD63 FD160. Trip Unit. Rated Current (A) FD63 (2,3 & 4 pole) frame reaking capacities 2, 3 and types Single pole types Icu 0/415V in k eff. Type 18 18 S 36 36 N H L 1 1 Icu 2/2V in k eff. N H Protection LTM Line thermal magnetic protection LTM Selective thermal

More information

FD frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FD160. Trip Unit. Rated Current (A)

FD frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FD160. Trip Unit. Rated Current (A) frame reaking capacities 2, 3 and 4 pole types Single pole types Icu 0/415V in k eff. Type 18 S 36 N H L 1 Icu 230/2V in k eff. N H Protection Order odes LTM Line thermal magnetic protection LTM Selective

More information

FE Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FE160 FE250. Protection. Trip Unit. Rated Current (A)

FE Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FE160 FE250. Protection. Trip Unit. Rated Current (A) rame reaking capacities Icu 0/415V in k eff. Type V 36 N H L 1 1 Protection LTM Line thermal magnetic protection LTM Selective thermal magnetic protection TM enerator thermal magnetic protection Mag reak

More information

FE Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FE160 FE250. Protection. Trip Unit. Rated Current (A)

FE Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FE160 FE250. Protection. Trip Unit. Rated Current (A) rame reaking capacities Icu 400/415V in k eff. Type V 36 N H L 1 1 Protection Order odes LTM Line thermal magnetic protection LTM Selective thermal magnetic protection TM enerator thermal magnetic protection

More information

FG Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FG400 FG630. Protection. Trip Unit FG400 FG630

FG Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FG400 FG630. Protection. Trip Unit FG400 FG630 rame reaking capacities cu /415V in k eff. Type N 50 50 H 80 80 L 150 150 Protection Order odes Trip Unit Rated urrent () 350 500 Premon S SMR2 Premon S Selective electronic protection. SMR2 Modular electronic

More information

FK Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FK800 FK1250 FK1600. Protection. Rated Current (A) Trip Unit FK800 FK1250 FK1600

FK Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FK800 FK1250 FK1600. Protection. Rated Current (A) Trip Unit FK800 FK1250 FK1600 K rame reaking capacities Icu 400/415V in k eff. Type V K K K N H 80 80 80 L 100 100 Protection Order odes Trip Unit K K K Rated urrent () 630 LTM Mag reak SMR1e (1) SMR1s (1) SMR1g (1) LTM Line thermal

More information

FK Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FK800 FK1250 FK1600. Protection. Rated Current (A) Trip Unit FK800 FK1250 FK1600

FK Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FK800 FK1250 FK1600. Protection. Rated Current (A) Trip Unit FK800 FK1250 FK1600 K rame reaking capacities Icu 400/415V in k eff. Type V K K12 K N H 80 80 80 L 100 100 Protection Trip Unit K K12 K Rated urrent () 12 LTM Mag reak SMR1e (1) SMR1s (1) SMR1g (1) LTM Line thermal magnetic

More information

C1251N DC and C1251N 1000 V

C1251N DC and C1251N 1000 V T I Catalogue numbers C25N DC and C25N 000 V E2409 Compact C25N DC with magnetic trip unit (complete device - fixed/fc) Compact C25N DC P2 46034 P4 46036 C25N 000 V basic frame (separate components - fixed/fc)

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Molded case circuit breakers

Molded case circuit breakers Molded case circuit breakers Metasol 30F to 250F Series Type Type and Pole Rated current, In Rated operational voltage, Ue Rated insulation voltage, Ui Rated impulse withstand voltage, Uimp Frame Size(F)

More information

Compact NR630. NR100F to NR630F

Compact NR630. NR100F to NR630F Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS

More information

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES MAY 2018 Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 125 380 415 10 440 460 10 480 550 7.5 600 5 NEMA-ABI

More information

Low breaking capacity moulded case circuit breakers

Low breaking capacity moulded case circuit breakers New series EB2S of MCCBs has excellent performances with reduced dimensions and new modern design. Advantages of low breaking capacity MCCBs Unique accessory cover opens with only one screw. Practical

More information

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES APRIL 2015 Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 380 415 440 460 480 550 600 NEMA-ABI 240 (HIC)

More information

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES AUGUST 2017 P. 07 P. 08 DMX3 ACB from 630 A to 2500 A Fixed version Draw-out version P. 12 cat.a Ui690V Uimp6kV 50 60Hz

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

price list IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

price list IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES price list THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES APRIL 2014 P. 07 P. 08 DMX3 ACB from 630 A to 2500 A Fixed version Draw-out version P. 13 cat.a Ui690V Uimp6kV 50 60Hz

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

Siemens switchgear. Tried, tested, trusted. Circuit Breakers

Siemens switchgear. Tried, tested, trusted. Circuit Breakers * MP - Maximum etail Price Siemens Ltd. LV SG - Power Distribution Products MP Eff. 01-10-2014 13 MCCB: Sentron 3VT1...5 ated current - 16A to 1600A 3 and 4 pole versions Breaking capacity from 25kA to

More information

WORKSHOP SPECIFICATIONS

WORKSHOP SPECIFICATIONS WORKSHOP SPECIFICATIONS DPX 3 160 & 250 MOULDED CASE CIRCUIT BREAKERS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DPX 3 RANGE Not only do DPX³ 160 and DPX 3 250 MCCBs provide

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

GE Consumer & Industrial Power Protection. New. ElfaPlus Unibis. Compact MCB s. Saving up to 50% space in distribution boards. GE imagination at work

GE Consumer & Industrial Power Protection. New. ElfaPlus Unibis. Compact MCB s. Saving up to 50% space in distribution boards. GE imagination at work GE Consumer & Industrial Power Protection New ElfaPlus Unibis Compact MCB s Saving up to 50% space in distribution boards GE imagination at work 2 Advantages 6 Miniature circuit breakers - Series EPC

More information

P. 07 DMX³ ACB from 630 A to 6300 A. P. 11 DMX SP 2500 ACB 630 A to 2500 A. P. 14 DRX MCCBs

P. 07 DMX³ ACB from 630 A to 6300 A. P. 11 DMX SP 2500 ACB 630 A to 2500 A. P. 14 DRX MCCBs MARCH Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 125 380 415 10 440 460 10 480 550 7.5 600 5 NEMA-ABI 240 25 (HIC) 480 7.5 600 5 DRX100B P. 07 DMX³ ACB from 630 A to 6300 A Fixed version

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

All round protection guaranteed

All round protection guaranteed s With SLR ll round protection guaranteed Betagard MCB 5SL Inspiring Safety nswers for infrastructure. Overview s a culture Siemens has always endeavoured to introduce innovative products worldwide. The

More information

GE Consumer & Industrial Power Protection. Record SL. Moulded Case Circuit Breakers Standard Line. GE Imagination at work

GE Consumer & Industrial Power Protection. Record SL. Moulded Case Circuit Breakers Standard Line. GE Imagination at work GE Consumer & Industrial Power Protection Moulded Case Circuit Breakers Standard Line GE Imagination at work The new GE Molded Case Circuit Breaker family is a line of reliable, simple and easy to use

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

GE Consumer & Industrial Power Protection. New. ElfaPlus Unibis. Compact MCB s. Saving up to 50% space in distribution boards. GE imagination at work

GE Consumer & Industrial Power Protection. New. ElfaPlus Unibis. Compact MCB s. Saving up to 50% space in distribution boards. GE imagination at work GE Consumer & Industrial Power Protection New ElfaPlus Unibis Compact MCB s Saving up to 50% space in distribution boards GE imagination at work 2 Advantages 6 Miniature circuit breakers - Series EPC

More information

Ordering information for XT1, XT2, XT3, XT4 UL/CSA Accessories

Ordering information for XT1, XT2, XT3, XT4 UL/CSA Accessories Ordering information for XT1, XT2, XT3, XT4 UL/CSA Accessories Fixed part of plug-in Fixed part of withdrawable Fixed parts, conversion kits and accessories for fixed parts Fixed part of plug-in (P) 3P

More information

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE. Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE Distributor : LEGRAND ELECTRIC LIMITED Great King Street North, Birmingham, B19 2LF Tel : 0870 608 9000 Fax : 0870 608 9004 CONSUMER UNIT BRO.10.05.??K

More information

Miniature circuit breakers

Miniature circuit breakers Miniature circuit breakers Miniature circuit breaker ETIMAT 6 Rated short-circuit capacity Rated current Tripping characteristic 6 ka 6-63 A B, C 1-pole 6 230/400 002111512 002141512 112 12/108 10 230/400

More information

SENTRON VL Series Product Specifications

SENTRON VL Series Product Specifications SENTRON VL Series Product Specifications VL 400 Frame 400 s Electronic Releases ETU TRIP RELEASE 315 12-315 3VL4731 - A 3-0AA0 400-400 3VL4740 - A 3-0AA0 3 = 3 poles All VL400 circuit-breakers are shipped

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

(p. 47) (p. 155) (p. 155)

(p. 47) (p. 155) (p. 155) 0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic

More information

Thermal magnetic and trip-free switches

Thermal magnetic and trip-free switches 87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

L&T SWITCHGEAR S A F E & S U R E. Moulded Case Circuit Breakers

L&T SWITCHGEAR S A F E & S U R E. Moulded Case Circuit Breakers L&T SWITCHGER S F E & S U R E Moulded Case Circuit Breakers Introduction Larsen & Toubro infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering,

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

New DX 3 High rating & breaking capacity

New DX 3 High rating & breaking capacity New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

MC FRAME SIZE 1 / UP TO 160A

MC FRAME SIZE 1 / UP TO 160A 8 W CIRCUIT BREAKER 3 POLE UP TO 160A WITH THERMAL MAGNETIC RELEASE TYPES MC1B-A, MC1N-A, MC1H-A For system and line protection Adjustable overload release Ir: 0,8 1 x In (factory setting 0,8 x In) Adjustable

More information

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035 Instruction Bulletin 4402-997-0 February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker

More information

MCCB Accessories to suit AF

MCCB Accessories to suit AF MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal

More information

Moulded Case Circuit Breakers

Moulded Case Circuit Breakers L&T SWITCHGER S F E & S U R E imp: k U 8 V Ue V, 60Hz. :4 0/ Ic u : 70k, I :0%I C T: cs cu D2 S IS 3947-2 IEC 60947-2 E 60947-2 - Moulded Case Circuit Breakers bout us Larsen & Toubro is a technology-driven

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

Signal lamps RS, RSB A20. Technical data RS, RSB. Dimensional drawing of RS, RSB. Number of poles Rated voltage Un

Signal lamps RS, RSB A20. Technical data RS, RSB. Dimensional drawing of RS, RSB. Number of poles Rated voltage Un Signal lamps S, S echnical data S, S Standards Number of poles ated voltage Un Light source Light source capacity Colours W Illumination erminal capacity Mounting mm2 Degree of protection mbient air temperature

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

LG Moulded Case Circuit Breakers - 3P

LG Moulded Case Circuit Breakers - 3P Model Description ka at 415V GBN103/16 100AF/16AT 3P MCCB GBN103/20 100AF/20AT 3P MCCB GBN103/25 100AF/25AT 3P MCCB GBN103/32 100AF/32AT 3P MCCB GBN103/40 100AF/40AT 3P MCCB GBN103/50 100AF/50AT 3P MCCB

More information

Motor Circuit Breakers C4

Motor Circuit Breakers C4 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short

More information

Kit EST1 6pcs 1SYN450207R0001 Kit EST2 6pcs. 1SYN450202R0001 Kit EST2 8pcs Kit EST3 6pcs. 1SYN450203R0001 Kit EST3 8pcs. 1SYN450209R0001 Kit EST4 6pcs

Kit EST1 6pcs 1SYN450207R0001 Kit EST2 6pcs. 1SYN450202R0001 Kit EST2 8pcs Kit EST3 6pcs. 1SYN450203R0001 Kit EST3 8pcs. 1SYN450209R0001 Kit EST4 6pcs Accessories for T-Max MCCBs Extended Spreaded terminals - ES T T2 T4 T5 Kit EST 6pcs SYN45020R000 Kit EST 8pcs SYN450207R000 Kit EST2 6pcs SYN450202R000 Kit EST2 8pcs SYN450208R000 Kit ES 6pcs SYN450203R000

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Circuit breakers. Panorama. PB111746_30.eps PB111749_30.eps

Circuit breakers. Panorama. PB111746_30.eps PB111749_30.eps Protection Circuit breakers Panorama PB76_0.eps PB79_0.eps PB75_0.eps PB75_0.eps PB757_0.eps PB758_0.eps Circuit breakers C60 N0 Performance Number of poles P P P P P + N P + N Width (module 9 mm) 6 8

More information

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with

More information

Catalogue No. 10!64E.

Catalogue No. 10!64E. www.terasaki.co.jp Catalogue No. 10!6E TBLE OF CONTENTS 1. Ratings and Specifications 1-1 Molded Case Circuit Breakers zfixed thermal and fixed magnetic MCCBs 1-2 cswitch-disconnectors 1- xdjustable thermal

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

GE Consumer & Industrial

GE Consumer & Industrial WavePro LT Busway System GE Consumer & Industrial General Electric Consumer & Industrial business was created in January of 2004 when GE Consumer Products merged with GE Industrial Systems. GE Consumer

More information

3VF3 to 3VF8 Circuit-Breakers

3VF3 to 3VF8 Circuit-Breakers 3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating

More information

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L

More information

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager The RX 3 and DX-E ranges provide essential functions for the protection requirements of people and property in residential and small commercial buildings Two breaking capacities, 4500 and 6000 (IEC 60898-1)

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

3VT Kompaktleistungsschalter bis 630A

3VT Kompaktleistungsschalter bis 630A Katalog LV 36 AT Österreich - Auszug 2012 3VT Kompaktleistungsschalter bis 630A SENTRON Schutz-, Schalt- und Messtechnik www.siemens.com/lowvoltage 3VT1 Molded Case Circuit Breakers up to 160 A 1 Technical

More information

Jtec 489 UL489 Branch Circuit Breaker

Jtec 489 UL489 Branch Circuit Breaker Jtec 489 UL489 Branch Circuit Breaker 10kA Miniature Circuit Breaker R The Jtec 489 range is UL 489 listed (File E255530). Available in trip curves Z (v. quick), B (quick), C (medium), K (motor) and D

More information

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State

More information

EDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards

EDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards -P, -P and J-P (quipment Protection evice) ircuit reakers for round ault Protection in N Panelboards Square -P, -P and J-P (quipment Protection evice) ircuit reakers are 1-pole thermal-magnetic circuit

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

NEW TX³ RANGE PROTECTION YOU CAN RELY ON TX³ NEW RANGE TRUSTED PROTECTION FOR YOUR INSTALLATIONS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW TX³ RANGE PROTECTION YOU CAN RELY ON Designed to meet the requirements of

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker

More information

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45]

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45] Multi 9 System Catalog UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers Figure 46: UL 489/CSA C22.2 No.5 Listed C60 240 Vac Circuit Breaker with Box Lug Terminals Figure 47: UL 489/CSA C22.2 No.5 Listed

More information

COMPLETE SOLUTIONS FOR POWER PROTECTION

COMPLETE SOLUTIONS FOR POWER PROTECTION COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

Low Voltage A GE Power Controls Company. General catalogue

Low Voltage A GE Power Controls Company. General catalogue Low Voltage A GE Power Controls Company General catalogue this is a blanc page Miniature circuit breakers A Miniature circuit breakers AC miniature circuit breakers Benefits of the new MCB s A 3 The AEG

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

ACS motor protection circuit breakers KT 7 Introduction

ACS motor protection circuit breakers KT 7 Introduction Introduction Automatic Type 2 coordination The right circuit breaker for all applications The KT 7 circuit breaker family consists of two basic frame sizes of mm and 5 mm in three variations with different

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

30 ma Ground Fault (Earth Leakage) Modules. Product Description

30 ma Ground Fault (Earth Leakage) Modules. Product Description August 2006 0 ma Ground Fault (Earth Leakage) Modules 5-0 ma Ground Fault (Earth Leakage) Modules Clockwise from Left:,, MCCBs Shown with Ground Fault (Earth Leakage) Modules Product Description Eaton

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in

More information

GE Industrial Solutions. New. Record Plus. Draw-out Circuit Breakers Selective & Current Limiting. GE imagination at work

GE Industrial Solutions. New. Record Plus. Draw-out Circuit Breakers Selective & Current Limiting. GE imagination at work GE Industrial Solutions New Record Plus Draw-out Circuit Breakers Selective & Current Limiting GE imagination at work Record Plus Moulded Case Circuit Breakers Selective and Current Limiting The Record

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information