C1251N DC and C1251N 1000 V

Size: px
Start display at page:

Download "C1251N DC and C1251N 1000 V"

Transcription

1 T I Catalogue numbers C25N DC and C25N 000 V E2409 Compact C25N DC with magnetic trip unit (complete device - fixed/fc) Compact C25N DC P P C25N 000 V basic frame (separate components - fixed/fc) Compact C25N 000V 400 A A A E24092 E Electronic trip unit Selective protection STR35SE N Motor protection STR35ME N Universal protection STR55UE N Sensors for neutral protection or "earth fault" Neutral protection Installation on neutral pole inside the circuit-breaker 500 A (reduced neutral) A A A "Earth fault" protection Installation on outgoing neutral conductor protected outside the circuit-breaker 800 A A A F-40 version: E5040.indd

2 Installation and connection Compact C25N DC and 000 V E2386 E23836 Fixed/RC device = fixed/fc device + RC kit Compact N Flat or edgewise RC kit P 4646 Comprising: RCs 6x P 8x short terminal shields 2x P 2x Withdrawable device = fixed/fc device + drawout kit Compact N Flat pad kit P Edgewise pad kit P Mixed kit P Comprising: Moving chassis x P x Fixed chassis x P x 4682 Short terminal shields 2x P 2x Plugs 3x P 4x Pads Flat 6x P 8x Edgewise 6x P 8x Mixed 3x x P 4x x E5040.indd version: 4. F-4

3 Accessories Compact C25N DC and 000 V E23859 Connection accessories Terminals for bare cable (with terminal shield) complete set (long terminal shields) for 3 cables 70 mm² y S y 85 mm² complete set (long terminal shields) for 4 cables 70 mm² y S y 240 mm² P P E23860 E2386 E23862 Connection pads For Compact N fixed/fc Edgewise pads ( piece) For fixed/rc Compact N () Edgewise pads ( piece) Flat pads ( piece) For N () withdrawable chassis Flat pads ( piece) Edgewise pads ( piece) () These pads are included in the part number of the complete fixed/rc or withdrawable device. Additional pads for cables (for Compact equipped with edgewise pads) For 4 cables S y 300 mm² fitted with crimped cable lugs ( piece) E23856 E23839 E23840 Fixed/FC spreaders upline or downline clearance P Sealable terminal shields Short ( piece) 3 P P Long ( piece) 3 P P Electrical auxiliaries Auxiliary switch OF + SD OF + SD 4490 CAM for rotary handle Changeover micro-contact "Plugged-in" position "Withdrawn" position SDE contact Compact T with remote control Compact TS with remote control Voltage releases MX AC 50/60 Hz or DC (shunt trip) / / / / MN (undervoltage release) AC 50/60 Hz DC 48 (50 Hz) / / / (60 Hz) / / MN 220/240 V AC with time delay Composed of: MN 250 V DC Delay unit 220/240 V 50/60 Hz F-42 version: E5040.indd

4 Accessories (cont.) Compact C25N DC and 000 V (cont.) E2384 E23833 E23842 Electrical auxiliaries (cont.) Auxiliary wire block (cont.) Moving part Short wires N type 3 term term Long wire N type 0 term Fixed part All types 3 term term term Pack of 24 female clips Disconnectable socket for auxiliary circuits Socket (6 wires) with plunger extension for testing 4684 Additional socket (6 wires) 4928 Motor mechanism modules Motor mechanism modules T25 AC 50/60 Hz DC Motor mechanism modules TS80/00/25 AC 50/60 Hz DC 220/ / / / / / / / / / Specific accessories for remote controls Locking device for Ronis key lock Or Profalux KS5 B24 D4Z (lock not supplied, cannot be fitted on source changeover system) Ronis key lock Profalux key lock KS5 B24 D4Z Rotary handles Direct rotary handles Standard With black toggle Wateright shield (CNOMO) E23843 E23844 Extended rotary handles With door locking Front door Short shaft (= ) Long shaft (= ) Rear door Short shaft (= ) 4687 Long shaft (= ) Without door locking Front door Short shaft (= ) E23845 E23846 E23847 Transformation accessories with extended rotary handle With door locking Front door Short shaft Long shaft Rear door Short shaft Long shaft Without door locking Front door Short shaft Shaft bracket for short shaft (always included on rotary handles with long shaft) E5040.indd version: 4. F-43

5 - Catalogue numbers Accessories (cont.) Compact C25N DC and 000 V (cont.) E23858 Testing devices Test kit Battery operated (battery not included) E3627 Portable test kit Spare test plug for portable test kit Wiring kit (spare part) E23849 Locks, interlocking Locking by padlock and/or key lock Of the toggle (in "OFF" position) By 3 padlocks (not supplied) E23848 E2383 E23850 Of the rotary handle (circuit-breaker in "OFF" position) By 3 padlocks (not supplied) Built-in key lock Ronis Profalux KS5 B24 D4Z Withdrawable chassis locking By 3 padlocks (not supplied) Built-in Locking device for or 2 keylocks (not supplied) Keylocks for locking in draw-out position (free key) key lock Ronis Profalux KS5 B24 D4Z set of 2 keylocks Ronis ( key only) Profalux KS5 B24 D4Z Keylocks for locking in draw-in position (free key) key lock Ronis 35A 4945 Profalux KS5 B24 D4Z Door interlock, connected position locking device Racking interlock locking device Mechanical interlocking (for fixed breakers with rotary handle) Mechanical device DB760 E23854 Mechanical interlocking (for fixed breakers with rotary handle) set of 2 keylocks ( key only) Ronis Profalux KS5 B24 D4Z Installation accessories Door cut-out grommet For fixed breaker E23855 Escutcheon with handle extension (IP40), for fixed or withdrawable device without remote control DB0572 IP40 door frame with inspection windows for fixed or withdrawable device with manual control 4683 DB0573 IP40 door frame with inspection windows for fixed or withdrawable device with rotary handle DB0574 Accessories for C25N withdrawable multifunction chassis IP40 door frame for multifunction chassis IP20 fine wire cover Plug-in clip shutter On fixed chassis ( piece) F-44 version: E5040.indd

6 Accessories (cont.) Compact C25N DC and 000 V (cont.) E23852 Installation accessories (cont.) Sealing accessories For trip unit ( set) For cover ( set) E23853 Circuit label-holder Set of E23864 Spare parts Cover /4P E23865 Extended toggle Standard Long for extended escutcheon (withdrawable device) E23866 Toggle for Rotary handle Black Red 4697 Visu module V80 to V Plug-in clip for withdrawable chassis (pair) E5040.indd version: 4. F-45

Compact NR630. NR100F to NR630F

Compact NR630. NR100F to NR630F Low voltage switchgear Compact NR NR100F NR630F The Compact NS range has revolutionised the world of moulded-case circuit breakers. For installations not requiring the high performance levels of the NS

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A Low voltage electrical distribution Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A User manual 09/2009 User manual for circuit breakers and switch-disconnectors Masterpact

More information

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity LV switch-disconnectors Catalogue Merlin Gerin 40 to 2500 A We do more with electricity LV switch-disconnectors The various low-voltage applications 2 from 40 to 2500 A 4 Compact from 80 to 1250 A 5 Masterpact

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

Circuit breakers. Panorama. PB111746_30.eps PB111749_30.eps

Circuit breakers. Panorama. PB111746_30.eps PB111749_30.eps Protection Circuit breakers Panorama PB76_0.eps PB79_0.eps PB75_0.eps PB75_0.eps PB757_0.eps PB758_0.eps Circuit breakers C60 N0 Performance Number of poles P P P P P + N P + N Width (module 9 mm) 6 8

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

WORKSHOP SPECIFICATIONS

WORKSHOP SPECIFICATIONS WORKSHOP SPECIFICATIONS DPX 3 160 & 250 MOULDED CASE CIRCUIT BREAKERS THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DPX 3 RANGE Not only do DPX³ 160 and DPX 3 250 MCCBs provide

More information

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

Thermal magnetic and trip-free switches

Thermal magnetic and trip-free switches 87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

Circuit protection and control devices 0.5 to 6300 A

Circuit protection and control devices 0.5 to 6300 A Electrical distribution Circuit protection and control devices 0.5 to 6300 A LV product characteristics 2009 m TOOLS schneider-electric.com The technical guide This international site allows you to access

More information

Compact Merlin Gerin 80 to 3200 A

Compact Merlin Gerin 80 to 3200 A LV power air circuit breakers and switch-disconnectors Catalogue Compact Merlin Gerin 80 to 3200 A 2005 Industries SA 5, rue Nadar 92506 Rueil-Malmaison Cedex France Tel : +33 (0)1 41 29 82 00 Fax : +33

More information

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES MAY 2018 Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 125 380 415 10 440 460 10 480 550 7.5 600 5 NEMA-ABI

More information

FD frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FD63 FD160. Trip Unit. Rated Current (A) FD63 (2,3 & 4 pole)

FD frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FD63 FD160. Trip Unit. Rated Current (A) FD63 (2,3 & 4 pole) frame reaking capacities 2, 3 and types Single pole types Icu 0/415V in k eff. Type 18 18 S 36 36 N H L 1 1 Icu 2/2V in k eff. N H Protection LTM Line thermal magnetic protection LTM Selective thermal

More information

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES AUGUST 2017 P. 07 P. 08 DMX3 ACB from 630 A to 2500 A Fixed version Draw-out version P. 12 cat.a Ui690V Uimp6kV 50 60Hz

More information

FD frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FD160. Trip Unit. Rated Current (A)

FD frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FD160. Trip Unit. Rated Current (A) frame reaking capacities 2, 3 and 4 pole types Single pole types Icu 0/415V in k eff. Type 18 S 36 N H L 1 Icu 230/2V in k eff. N H Protection Order odes LTM Line thermal magnetic protection LTM Selective

More information

Low voltage electrical distribution. Compact NS. Circuit breakers and switch-disconnectors from 630 to 1600 A. User manual 10/2017

Low voltage electrical distribution. Compact NS. Circuit breakers and switch-disconnectors from 630 to 1600 A. User manual 10/2017 Low voltage electrical distribution Compact NS Circuit breakers and switch-disconnectors from 630 to 1600 A User manual 10/2017 User manual for circuit breakers and switch-disconnectors Compact NS630b-1600

More information

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES APRIL 2015 Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 380 415 440 460 480 550 600 NEMA-ABI 240 (HIC)

More information

price list IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

price list IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES price list THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES APRIL 2014 P. 07 P. 08 DMX3 ACB from 630 A to 2500 A Fixed version Draw-out version P. 13 cat.a Ui690V Uimp6kV 50 60Hz

More information

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035 Instruction Bulletin 4402-997-0 February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker

More information

F.T.M.C. F.T.M.C. Motor Operator For MCCB. MCCB Accessories. Motor Operator. Part No. Frame MOPF240 FTCF F MOPJ240 F FTCJ MOPK240 FTCK

F.T.M.C. F.T.M.C. Motor Operator For MCCB. MCCB Accessories. Motor Operator. Part No. Frame MOPF240 FTCF F MOPJ240 F FTCJ MOPK240 FTCK Motor Operator For MCCB Motor Operator Ref.NO. F101105 MOPF20 F101106 MOPJ20 F101107 MOPK20 F101108 MOPLG20 F101109 MOPL20 58 TYPE RHM Rotary Handle Mechanisms 59 ROTARY HANDLE MCCB Ref.No. Rotary Handle

More information

3VF3 to 3VF8 Circuit-Breakers

3VF3 to 3VF8 Circuit-Breakers 3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating

More information

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker

More information

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State

More information

FE Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FE160 FE250. Protection. Trip Unit. Rated Current (A)

FE Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FE160 FE250. Protection. Trip Unit. Rated Current (A) rame reaking capacities Icu 0/415V in k eff. Type V 36 N H L 1 1 Protection LTM Line thermal magnetic protection LTM Selective thermal magnetic protection TM enerator thermal magnetic protection Mag reak

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45]

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45] Multi 9 System Catalog UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers Figure 46: UL 489/CSA C22.2 No.5 Listed C60 240 Vac Circuit Breaker with Box Lug Terminals Figure 47: UL 489/CSA C22.2 No.5 Listed

More information

Low voltage. EasyPact EZC. Moulded-case circuit breakers from 15 to 630 A. Catalogue 2013

Low voltage. EasyPact EZC. Moulded-case circuit breakers from 15 to 630 A. Catalogue 2013 Low voltage EasyPact EZC Moulded-case circuit breakers from 15 to 630 A Catalogue 2013 EasyPact EZC General contents Presentation 2 Functions and characteristics A-1 Busbars B-1 Installation guide C-1

More information

Compact NS. Installation recommendations

Compact NS. Installation recommendations Compact NS Installation recommendations Presentation 6 Functions and characteristics Operating conditions 144 Installation in switchboards 145 Power supply and weights 145 Safety clearances and minimum

More information

FK Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FK800 FK1250 FK1600. Protection. Rated Current (A) Trip Unit FK800 FK1250 FK1600

FK Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FK800 FK1250 FK1600. Protection. Rated Current (A) Trip Unit FK800 FK1250 FK1600 K rame reaking capacities Icu 400/415V in k eff. Type V K K K N H 80 80 80 L 100 100 Protection Order odes Trip Unit K K K Rated urrent () 630 LTM Mag reak SMR1e (1) SMR1s (1) SMR1g (1) LTM Line thermal

More information

FE Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FE160 FE250. Protection. Trip Unit. Rated Current (A)

FE Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FE160 FE250. Protection. Trip Unit. Rated Current (A) rame reaking capacities Icu 400/415V in k eff. Type V 36 N H L 1 1 Protection Order odes LTM Line thermal magnetic protection LTM Selective thermal magnetic protection TM enerator thermal magnetic protection

More information

Masterpact NW DC Circuit Breakers

Masterpact NW DC Circuit Breakers Masterpact NW DC Circuit Breakers Catalog 0613CT0501 R06/15 2015 Class 0613 CONTENTS Description............................................. Page General Information..........................................

More information

P. 07 DMX³ ACB from 630 A to 6300 A. P. 11 DMX SP 2500 ACB 630 A to 2500 A. P. 14 DRX MCCBs

P. 07 DMX³ ACB from 630 A to 6300 A. P. 11 DMX SP 2500 ACB 630 A to 2500 A. P. 14 DRX MCCBs MARCH Ui690V Uimp6kV 50 60Hz Ics=50%Icu Ue Icu [VAC] [ka] 220 240 125 380 415 10 440 460 10 480 550 7.5 600 5 NEMA-ABI 240 25 (HIC) 480 7.5 600 5 DRX100B P. 07 DMX³ ACB from 630 A to 6300 A Fixed version

More information

C60H-DC C curve. Catalogue numbers

C60H-DC C curve. Catalogue numbers distriution systems PB104013-34 The supplementary protectors are used in direct current circuits (Industrial control and automations, transport, renewale energy...). They comine the following functions

More information

MCCB Accessories to suit AF

MCCB Accessories to suit AF MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal

More information

MOULDED CASE CIRCUIT BREAKERS BH630N, BH630S

MOULDED CASE CIRCUIT BREAKERS BH630N, BH630S MOULDED CASE CIRCUIT BREAKERS BH6N, BH6S F BH6N, BH6S COMMERCIAL INFORMATION Switching units, withdrawable device, plug-in device...f4 Switch-disconnector unit...f6 Connecting sets...f7 Mounting sets...f9

More information

Low voltage circuit breakers

Low voltage circuit breakers Comprehensive Catalogue 2006 Super Solution Low voltage circuit breakers A-3. Accessories TD & TS MCCB Index Electrical auxiliaries Undervoltage release, UVT Shunt release, SHT Auxiliary switch (AX),

More information

F.T.M.C. Air Circuit Breakers. ACB Accessories for frame 1 & 2. Shunt trip. Motorised spring charging unit. Und ervoltage rele ase.

F.T.M.C. Air Circuit Breakers. ACB Accessories for frame 1 & 2. Shunt trip. Motorised spring charging unit. Und ervoltage rele ase. B Accessories for frame & Shunt trip A wide range of optional accessories have been developed that are compatible with all PowerWAVE Plus air circuit breakers, regardless of nominal rating or. Each one

More information

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE. Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE Distributor : LEGRAND ELECTRIC LIMITED Great King Street North, Birmingham, B19 2LF Tel : 0870 608 9000 Fax : 0870 608 9004 CONSUMER UNIT BRO.10.05.??K

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with

More information

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A Low Voltage EasyPact CVS Moulded-case circuit breakers from 16 to 100 A Catalogue 2013 EasyPact CVS Contents Functions and characteristics A-1 Installation recommendations B-1 Dimensions and connection

More information

FK Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FK800 FK1250 FK1600. Protection. Rated Current (A) Trip Unit FK800 FK1250 FK1600

FK Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FK800 FK1250 FK1600. Protection. Rated Current (A) Trip Unit FK800 FK1250 FK1600 K rame reaking capacities Icu 400/415V in k eff. Type V K K12 K N H 80 80 80 L 100 100 Protection Trip Unit K K12 K Rated urrent () 12 LTM Mag reak SMR1e (1) SMR1s (1) SMR1g (1) LTM Line thermal magnetic

More information

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric. K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles

More information

3VT Kompaktleistungsschalter bis 630A

3VT Kompaktleistungsschalter bis 630A Katalog LV 36 AT Österreich - Auszug 2012 3VT Kompaktleistungsschalter bis 630A SENTRON Schutz-, Schalt- und Messtechnik www.siemens.com/lowvoltage 3VT1 Molded Case Circuit Breakers up to 160 A 1 Technical

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

MC FRAME SIZE 1 / UP TO 160A

MC FRAME SIZE 1 / UP TO 160A 8 W CIRCUIT BREAKER 3 POLE UP TO 160A WITH THERMAL MAGNETIC RELEASE TYPES MC1B-A, MC1N-A, MC1H-A For system and line protection Adjustable overload release Ir: 0,8 1 x In (factory setting 0,8 x In) Adjustable

More information

Ordering information for XT1, XT2, XT3, XT4 UL/CSA Accessories

Ordering information for XT1, XT2, XT3, XT4 UL/CSA Accessories Ordering information for XT1, XT2, XT3, XT4 UL/CSA Accessories Fixed part of plug-in Fixed part of withdrawable Fixed parts, conversion kits and accessories for fixed parts Fixed part of plug-in (P) 3P

More information

GE Industrial Solutions. New. Record Plus. Draw-out Circuit Breakers Selective & Current Limiting. GE imagination at work

GE Industrial Solutions. New. Record Plus. Draw-out Circuit Breakers Selective & Current Limiting. GE imagination at work GE Industrial Solutions New Record Plus Draw-out Circuit Breakers Selective & Current Limiting GE imagination at work Record Plus Moulded Case Circuit Breakers Selective and Current Limiting The Record

More information

NS Feeder pillar up to 3200A

NS Feeder pillar up to 3200A NS Feeder pillar up to 3200A Advanced technology for low voltage, outdoor distribution Merlin Gerin Modicon Telemecanique Outdoor electrical distribution with advanced technology Merlin Gerin low voltage,

More information

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.

More information

FD Frame. Breaking capacities. Protection

FD Frame. Breaking capacities. Protection FD Frame Breaking capacities 2, 3 and types Single pole types Icu 0/415V C in k eff. Type FD FD C 18 18 Protection Trip Unit Rated Current () E LTM S 36 36 N LTMD H GTM L 1 1 Mag Break TM Icu 2/2V C in

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Overcurrent releases - description, specifications, characteristics specifications specifications description... BA5*37 COMMERCIAL INFORMATION Type designation specification for ordering...68 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

(p. 47) (p. 155) (p. 155)

(p. 47) (p. 155) (p. 155) 0 286 56 + 0 288 02 (p. 47) 0 286 74 + 0 288 02 (p. 155) 0 287 56 + 0 288 02 (p. 155) Dimensions see e-catalogue Elecical characteristics p. 162 Automatic air circuit breakers must be equipped with eleconic

More information

FG Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FG400 FG630. Protection. Trip Unit FG400 FG630

FG Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FG400 FG630. Protection. Trip Unit FG400 FG630 rame reaking capacities cu /415V in k eff. Type N 50 50 H 80 80 L 150 150 Protection Order odes Trip Unit Rated urrent () 350 500 Premon S SMR2 Premon S Selective electronic protection. SMR2 Modular electronic

More information

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus DISTRIBUTION SOLUTIONS GSec Gas-insulated switching and isolating apparatus GSec is a three-position SF6 gas-insulated switchdisconnector designed for use in medium voltage switchgear for secondary distribution

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Selection Checklist CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies Use this checklist to help you configure your CENTERLINE 2500 Motor Control Center. You can type in the fields

More information

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma... Contents Acti 9 MCBs, RCCB ic60h circuit breakers (curve B, C, D)... pages / to /4 ic60h and ic60h RCB0 10, 30 and 100 ma.... pages /5 to /8 Vigi ic60 add-on residual current devices.... pages /9 to /1

More information

Masterpact NW DC Circuit Breakers

Masterpact NW DC Circuit Breakers Masterpact NW DC Circuit Breakers Catalog 0613CT0501R1/07 2007 Class 0613DC CONTENTS Description..............................................Page Contents General Information Line 1.........................................

More information

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

NEW TX³ RANGE PROTECTION YOU CAN RELY ON TX³ NEW RANGE TRUSTED PROTECTION FOR YOUR INSTALLATIONS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW TX³ RANGE PROTECTION YOU CAN RELY ON Designed to meet the requirements of

More information

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011 Low Voltage Interpact Switch-disconnectors INS/INV40 to 2500 A Catalogue 2011 Interpact INS/INV Contents Presentation 2 Functions and characteristics A-1 Installation recommendations B-1 Dimensions and

More information

Air-insulated switchgear UniGear type ZS1

Air-insulated switchgear UniGear type ZS1 Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5

More information

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

IP20 degree of protection; IP40 degree of protection after installation in a distribution box RI 50 RI 50 is used for the protection of installations and devices (overload and short circuit), and as a disconnector in case of electric shock Simple and quick fixing to a 35 mm mounting rail in accordance

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers BBC BROWN BOVERI RP 6..2.8-2C Renewal Parts I-T-E Low-Voltage Power Circuit Breakers Type K-000, 4000, 0008, and 40008 Stationary and Drawout Mounted 000 and 4000 Amperes 600 Volts RP 6..2.8-2 Page 2 Table

More information

FE Frame. Breaking capacities. Protection

FE Frame. Breaking capacities. Protection FE Frame Breaking capacities Icu 0/415V C in k eff. Type FE FE2 V 36 N H L 1 1 LTM Line thermal magnetic protection LTMD Selective thermal magnetic protection GTM Generator thermal magnetic protection

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33 BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

Modeion MOULDED CASE CIRCUIT BREAKERS BL1600S

Modeion MOULDED CASE CIRCUIT BREAKERS BL1600S H MOULDED CASE CIRCUIT BREAKERS BL6S H BL6S COMMERCIAL INFORMATION Switching units, withdrawable device...h4 Overcurrent releases...h5 Signalling units...h5 Residual current monitor...h6 Current transformers

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

Power protection solutions

Power protection solutions Power protection solutions DMX A.C.Bs UP TO 4000 A In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and

More information

Price List. Low Voltage Distribution Products. With effect from March 12, schneider-electric.co.in

Price List. Low Voltage Distribution Products. With effect from March 12, schneider-electric.co.in Price List Low Voltage Distribution Products With effect from March 12, 2018 schneider-electric.co.in Price List Contents Smart Panels Introduction to Smart Panels............................... 5 Moulded

More information