Homepage > Products > Control units > VARYCONTROL > Control components > Type Easy. Type Easy

Size: px
Start display at page:

Download "Homepage > Products > Control units > VARYCONTROL > Control components > Type Easy. Type Easy"

Transcription

1 Homepage > Products > Control units > VARYCONTROL > Control components > Type Easy Type Easy QUICK AND EASY HANDLING Control components for VAV terminal units, to be mounted on the terminal unit for easy operation Simplified ordering and on-site assignment to rooms as selection is based on the nominal size of the duct Rapid volume flow rate setting without additional device Indicator light simplifies functional checking Proven technology of the Compact volume flow controllers Suitable for constant and variable volume flows as well as for V min / V max switching APPLICATION Application Electronic volume flow controllers of Type Easy are compact, all-in-one control devices for VAV terminal units Dynamic differential pressure transducer, electronic controller, and actuator are fitted together in one casing Suitable for different control tasks depending on how the input for the setpoint value signal is used The output signals of the room temperature controller, central BMS, air quality controller or similar units control the volume flow rate setpoint

2 Override control by means of switches or relays Volume flow rate actual value is available as linear voltage signal Standard filtration in comfort air conditioning systems allows for use of the controller in the supply air without additional dust protection. Since a partial volume flow is passed through the transducer in order to measure the volume flow rate, please note: With heavy dust levels in the room, suitable extract air filters must be provided. If the air is polluted with fluff or sticky particles, or if it contains aggressive media, Easy controllers cannot be used Application Electronic volume flow controllers of Type Easy are compact, all-in-one control devices for VAV terminal units Dynamic differential pressure transducer, electronic controller, and actuator are fitted together in one casing Suitable for different control tasks depending on how the input for the setpoint value signal is used The output signals of the room temperature controller, central BMS, air quality controller or similar units control the volume flow rate setpoint Override control by means of switches or relays Volume flow rate actual value is available as linear voltage signal Standard filtration in comfort air conditioning systems allows for use of the controller in the supply air without additional dust protection. Since a partial volume flow is passed through the transducer in order to measure the volume flow rate, please note: With heavy dust levels in the room, suitable extract air filters must be provided. If the air is polluted with fluff or sticky particles, or if it contains aggressive media, Easy controllers cannot be used DESCRIPTION Construction LMV-D3AL-F for LVC 227V-024T for LVC LMV-D3A-F for TVR 227V-024T für TVR

3 227V-024T for TVJ, TVT SMV-D3A for TVT LMV-D3A for TZ-Silenzio, TA-Silenzio, TVZ, TVA Operating modes Variable volume flow V V min max : minimum volume flow rate : maximum volume flow rate Constant value V min : constant volume flow rate V : 100 % max Signal voltage range 0 10 V DC Parts and characteristics Sensor for dynamic differential pressure measurements Mechanical stops for limiting the damper blade positions Actuators with overload protection Release button to allow for manual operation Construction LMV-D3AL-F for LVC 227V-024T for LVC LMV-D3A-F for TVR 227V-024T für TVR 227V-024T for TVJ, TVT SMV-D3A for TVT LMV-D3A for TZ-Silenzio, TA-Silenzio, TVZ, TVA Operating modes

4 Variable volume flow V V min max : minimum volume flow rate : maximum volume flow rate Constant value V min : constant volume flow rate V : 100 % max Signal voltage range 0 10 V DC Parts and characteristics Sensor for dynamic differential pressure measurements Mechanical stops for limiting the damper blade positions Actuators with overload protection Release button to allow for manual operation TECHNICAL INFORMATION Function, Technical data, Order code, Produktbeziehungen FUNCTION Functional description VAV terminal units control the volume flow in a closed loop, i.e. measurement comparison control. The volume flow rate is determined by measuring the differential pressure (effective pressure). For this purpose the VAV terminal unit is fitted with a differential pressure sensor. The integral differental pressure transducer transforms the effective pressure into a voltage signal. The volume flow rate actual value is hence available as a voltage signal. The factory setting is such that 10 V DC always corresponds to the nominal volume flow rate (V ). nom

5 The volume flow rate setpoint value comes from a higher-level controller (e.g. room temperature controller, air quality controller, central BMS) or from switch contacts. Variable volume flow control results in a value between V and V. It is possible to override the room temperature control, e.g. by a complete shut-off of the duct. The controller compares the volume flow rate setpoint value to the actual value and controls the integral actuator accordingly. The volume flow rate parameters V and V can be set on potentiometers. min max Volume flow control The volume flow controller works independent of the duct pressure Differential pressure fluctuations do not result in permanent volume flow rate changes To prevent the control from becoming unstable, a dead band is allowed within which the damper blade does not move. The factory set volume flow rate parameters can be altered by the customer min max Functional description VAV terminal units control the volume flow in a closed loop, i.e. measurement comparison control. The volume flow rate is determined by measuring the differential pressure (effective pressure). For this purpose the VAV terminal unit is fitted with a differential pressure sensor. The integral differental pressure transducer transforms the effective pressure into a voltage signal. The volume flow rate actual value is hence available as a voltage signal. The factory setting is such that 10 V DC always corresponds to the nominal volume flow rate (V ). nom The volume flow rate setpoint value comes from a higher-level controller (e.g. room temperature controller, air quality controller, central BMS) or from switch contacts. Variable volume flow control results in a value between V and V. It is possible to override the room temperature control, e.g. by a complete shut-off of the duct. The controller compares the volume flow rate setpoint value to the actual value and controls the integral actuator accordingly. The volume flow rate parameters V and V can be set on potentiometers. min max Volume flow control The volume flow controller works independent of the duct pressure Differential pressure fluctuations do not result in permanent volume flow rate changes To prevent the control from becoming unstable, a dead band is allowed within which the damper blade does not move. The factory set volume flow rate parameters can be altered by the customer min max

6 Principe de fonctionnement Régulateurs Easy et Compact 1 Sonde de pression différentielle 2 Servomoteur 3 Régulateur de débit 4 Signal de valeur de consigne Régulateur Easy

7 1 Régulateur Easy 2 V max - Potentiomètre 3 V min - Potentiomètre 4 Voyant lumineux 5 Bouton-poussoir de service 6 Raccordements pour capteur de pression effective 7 Capot de protection 8 Axe de blocage Illustration : LMV-D3A-F

8 TECHNICAL DATA Easy controller LMV-D3AL-F Supply voltage (AC) 24 V AC ± 20 %, 50/60 Hz Supply voltage (DC) 24 V DC 10/+20 % Power rating (AC) 3.5 VA max. Power rating (DC) 2 W max. Running time for s Setpoint value signal input 0 10 V DC, R > 100 kω a Actual value signal output 0 10 V DC, 0.5 ma max. IEC protection class III (protective extra-low voltage) Protection level IP 20 EC conformity EMC to 2014/30/EU, low voltage to 2014/35/EU Easy controller 227V-024T

9 Supply voltage (AC) 24 V AC ± 20 %, 50/60 Hz Supply voltage (DC) 24 V DC ± 20 % Power rating (AC) 5 VA max. Power rating (DC) 3 W max. Running time for s Setpoint value signal input 0 10 V DC, R > 100 kω a Actual value signal output 0 10 V DC, 0.5 ma max. IEC protection class III (protective extra-low voltage) Protection level IP 20 EC conformity EMC according to 2014/30/EU Easy controllers LMV-D3A and LMV-D3A-F

10 Supply voltage (AC) 24 V AC ± 20 %, 50/60 Hz Supply voltage (DC) 24 V DC 10/+20 % Power rating (AC) 5 VA max. Power rating (DC) 2.5 W max. Running time for s Setpoint value signal input 0 10 V DC, R > 100 kω a Actual value signal output 0 10 V DC, 0.5 ma max. IEC protection class III (protective extra-low voltage) Protection level IP 20 EC conformity EMC according to 2014/30/EU Easy controller 227V-024T

11 Supply voltage (AC) 24 V AC ± 20 %, 50/60 Hz Supply voltage (DC) 24 V DC ± 20 % Power rating (AC) 5 VA max. Power rating (DC) 3 W max. Running time for s Setpoint value signal input 0 10 V DC, R > 100 kω a Actual value signal output 0 10 V DC, 0.5 ma max. IEC protection class III (protective extra-low voltage) Protection level IP 20 EC conformity EMC according to 2014/30/EU Easyregler 227V-024T

12 Versorgungsspannung (Wechselspannung) 24 V AC ± 20 %, 50/60 Hz Versorgungsspannung (Gleichspannung) 24 V DC ± 20 % Anschlussleistung (Wechselspannung) Max. 5 VA Anschlussleistung (Gleichspannung) Max. 3 W Laufzeit für s Eingang Sollwertsignal 0 10 V DC, R > 100 kω a Ausgang Istwertsignal 0 10 V DC, max. 0,5 ma Schutzklasse III (Schutzkleinspannung) Schutzgrad IP 20 EG-Konformität EMV nach 2014/30/EU Easy controller SMV-D3A

13 Supply voltage (AC) 24 V AC ± 20 %, 50/60 Hz Supply voltage (DC) 24 V DC 10/+20 % Power rating (AC) 6 VA max. Power rating (DC) 3 W max. Running time for s Setpoint value signal input 0 10 V DC, R > 100 kω a Actual value signal output 0 10 V DC, 0.5 ma max. IEC protection class III (protective extra-low voltage) Protection level IP 20 EC conformity EMC according to 2014/30/EU Variants, Product details VARIANTS

14 Part number Type Type of VAV terminal unit M466EU1 LMV-D3AL-F LVC M466EU2 227V-024T LVC M466ES1 LMV-D3A-F TVR M466DC3 227V-024T TVR A V-024T TVJ, TVT M466ES3 SMV-D3A TVT M466ES2 LMV-D3A TZ-Silenzio, TA-Silenzio, TVZ, TVA Régulateur Easy LMV-D3AL-F

15 Régulateur Easy 227V-024T Régulateur Easy LMV-D3A

16 Régulateur Easy 227V-024T

17 Régulateur Easy 227V-024T Régulateur Easy SMV-D3A

18 PRODUCT DETAILS The Easy principle The Easy principle Sélectionner la dimension nominale

19 Régler le débit La diode verte s'allume : c'est prêt! Electrical connection, Commissioning, Characteristics

20 ELECTRICAL CONNECTION Répartition du bornier 1, : terre 2 ~, +: tension électrique 24 V 3 w: signal de valeur de consigne 0 10 V DC 4 U: signal de valeur réelle 0 10 V DC INBETRIEBNAHME Commissioning Use the potentiometer to set the minimum or maximum volume flow rate on site Take the adjustment value from the volume flow rate scale (sticker on each VAV terminal unit) Comply with the volume flow rate control range, do not set a volume flow rate which is below the minimum flow rate Volume flow rate range of LVC, TVR, TZ-Silenzio, TA-Silenzio, TVZ and TVA: % Volume flow rate range of TVJ and TVT: % Once the VAV terminal unit has been installed and wired, and the volume flow rate has been set, the unit is ready for operation Remove the transparent cover of the Easy controller only temporarily for wiring and commissioning Commissioning Use the potentiometer to set the minimum or maximum volume flow rate on site Take the adjustment value from the volume flow rate scale (sticker on each VAV terminal unit) Comply with the volume flow rate control range, do not set a volume flow rate which is below the minimum flow rate Volume flow rate range of LVC, TVR, TZ-Silenzio, TA-Silenzio, TVZ and TVA: % Volume flow rate range of TVJ and TVT: % Once the VAV terminal unit has been installed and wired, and the volume flow rate has been set, the unit is ready for operation Remove the transparent cover of the Easy controller only temporarily for wiring and commissioning Échelle de réglage de débit pour TVR-Easy

21 Chaque unité terminale VAV porte un autocollant avec une échelle de réglage de débit afin de déterminer les paramétrages sur site (voir exemple : TVR-Easy, grandeur nominale 200). Les pourcentages se rapportent à la plage de réglage qui peut être utilisé. Régulation à débit variable Les débits requis doivent être réglés sur site. Si V est réglé plus haut que V, V est fourni en tant que débit min max min Home Contacts Imprint Delivery and payment terms Privacy Disclaimer TROX GmbH

22 Homepage > Products > Control units > VARYCONTROL > Control components > Type Easy constant, même en cas d'émission d'un signal de consigne. Si V est réglé sur 0 %, le débit en résultant se situera entre la coupure et Vmax. Si le signal de consigne chute en min dessous de 0,5 V DC, le clapet de réglage se ferme (coupure). Régulation à débit constant Le débit constant est défini avec le potentiomètre V. Dans ce cas, le réglage du potentiomètre V est sans importance. min max Variable de pilotage en provenance du système centralisé de gestion du bâtiment (GTB-GTC) Pour que le système centralisé de gestion du bâtiment pilote le débit, il faut régler le potentiomètre V potentiomètre V max sur 0 % et le sur 100 %. Si le signal de consigne chute en dessous de 0,5 V DC, le clapet de réglage se ferme (coupure). Étant donné que le signal de consigne peut ou ne peut pas être inférieure à 0,1 V DC, une régulation prioritaire est recommandée pour la fermeture. min Home Contacts Imprint Delivery and payment terms Privacy Disclaimer TROX GmbH

23 Homepage > Products > Control units > VARYCONTROL > Control components > Type Easy Réglage usine À la livraison, les unités possèdent des réglages V min = 40 % et V max = 80 %. CHARACTERISTICS Caractéristiques du signal de valeur de consigne Home Contacts Imprint Delivery and payment terms Privacy Disclaimer TROX GmbH

24 Homepage > Products > Control units > VARYCONTROL > Control components > Type Easy TROX GmbH Online-Services Service-Hotlines Heinrich-Trox-Platz D Neukirchen-Vluyn Tel.: +49 (0) Fax: +49 (0) Order-Status (My TROX NET) TROX Academy Catalogue Download Your contact partner Online fault report BIM Sales Germany and technical consulting +49 (0) Contact Technical service +49 (0) Contact Home Contacts Imprint Delivery and payment terms Privacy Disclaimer TROX GmbH

Homepage > Products > Airflow Control - VAV and CAV > Variable air volume flow control - VARYCONTROL > Control components > Type Easy.

Homepage > Products > Airflow Control - VAV and CAV > Variable air volume flow control - VARYCONTROL > Control components > Type Easy. Homepage > Products > Airflow Control - VAV and CAV > Variable air volume flow control - VARYCONTROL > Control components > Type Easy Type Easy QUICK AND EASY HANDLING Control components for VAV terminal

More information

Type Pneumatic actuators

Type Pneumatic actuators Homepage > Products > External louvres - louvre blades > Multileaf dampers > Attachments > Type Pneumatic actuators Type Pneumatic actuators PNEUMATIC ACTUATORS FOR THE OPENING AND CLOSING OF DAMPERS IN

More information

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS Rectangular fire damper for use in extract air and exhaust air ducts of

More information

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF Rectangular VAV terminal units for standard applications regarding the supply air or extract air control in variable air volume

More information

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL

Control units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL Control units Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL The art of handling air Ventilation and air conditioning systems must fulfil complex and demanding requirements. With

More information

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL. Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL Type KUL FOR INSTALLATION INTO DUCTWORK Non-return dampers prevent unwanted airflows

More information

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK Type AK FOR LOW-LEAKAGE SHUT-OFF Circular shut-off dampers for shutting off volume flows in ventilation ducts

More information

TYPE EK-EU SMOKE CONTROL DAMPER

TYPE EK-EU SMOKE CONTROL DAMPER Homepage > PRODUCTS > Fire and Smoke Protection > Smoke Control Damper > Type EK-EU TYPE EK-EU SMOKE CONTROL DAMPER WITH TROXNETCOM AS AN OPTION CE COMPLIANT ACCORDING TO EUROPEAN REGULATIONS EK-EU WITH

More information

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Rectangular VAV terminal units for the extract air control in buildings with variable air volume

More information

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES Homepage > Products > Air Diffusers > Industrial diffusers > Diffusers for high momentum > Type ISH Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES Impulse diffusers with horizontal air discharge

More information

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES Circular ceiling swirl diffusers, with manual or motorised adjustment of the

More information

Parts and characteristics

Parts and characteristics Type TVZ FOR SUPPLY AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Highly

More information

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX Type TX FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS TYPE TVJ, OR EN Rectangular secondary silencers

More information

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE Homepage > Products > Sound attenuators > Splitter sound attenuators > Type MSA Type MSA Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

More information

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Rectangular VAV terminal units for the extract air control in buildings with variable air volume

More information

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Circular VAV terminal units for standard applications regarding the supply air or extract air control in variable air

More information

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS Homepage > Products > Control Systems > Variable volume flow control > VAV terminal units > Type TVLK Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS Plastic circular VAV terminal units

More information

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX Type TX FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS TYPE TVJ, OR EN Rectangular secondary silencers

More information

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Circular VAV terminal units for standard

More information

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK-Ex Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Circular shut-off

More information

Type Pneumatic actuators

Type Pneumatic actuators Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Pneumatic actuators Type Pneumatic actuators PNEUMATIC ACTUATORS FOR THE OPENING AND CLOSING OF DAMPERS IN AIR

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Type NAK. Gas-tight shut-off damper with pneumatic actuator Homepage > Products > Control units > Shut-Off dampers > Type NAK Type NAK FOR THE GAS-TIGHT SHUT-OFF OF DUCTS Gas-tight shut-off damper with pneumatic actuator Gas-tight shut-off dampers are designed

More information

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the extract air control in buildings with variable air volume systems and demanding acoustic requirements Highly

More information

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Type TVZ FOR SUPPLY AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Highly

More information

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate

More information

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK Type AKK FOR CONTAMINATED AIR Plastic circular shut-off dampers for shutting off aggressive

More information

VAV terminal units VARYCONTROL. Installation and commissioning manual. GB/en. LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK

VAV terminal units VARYCONTROL. Installation and commissioning manual. GB/en. LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK Installation and commissioning manual GB/en VAV terminal units VARYCONTROL LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK Read the instructions prior to performing any task! TROX GmbH Heinrich-Trox-Platz

More information

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION Hoepage > Products > Sound attenuators > Circular silencers > Type CA Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION Circular silencers Type CA for the reduction

More information

Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Explosion-proof actuators. Type Explosion-proof actuators

Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Explosion-proof actuators. Type Explosion-proof actuators Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Explosion-proof actuators Type Explosion-proof actuators FOR OPENING AND CLOSING MULTILEAF DAMPERS INSTALLED IN

More information

VersaWall SlimLine 1750

VersaWall SlimLine 1750 Index Stick built curtain wall 1 3/4"(44.5mm) profile Mur rideau avec profilé de 1 3/4"(44.5mm) Capped Couvercles à enclenchement Primary components - back sections Composantes principales - traverses

More information

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K . X X testregistrierung VAV terminal units Type Easy controller Compact controller Circular connection on the fan end For extract air systems with demanding acoustic requi rements VAV terminal units for

More information

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS Home > PRODOTTI > Unità di regolazione > VARYCONTROL > Unità terminali VAV > Serie TVA Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the extract air control

More information

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION Homepage > Products > Sound attenuators > Circular silencers > Type CS Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION Circular silencers, in rigid aluminium construction,

More information

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS Homepage > Products > External Louvres & Dampers > Multileaf dampers > Multileaf dampers > Type JZ Low leakage Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS Rectangular multileaf

More information

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN.

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN. Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN Type EN FOR THE PRECISE CONTROL OF NORMAL AND HIGH CONSTANT VOLUME FLOWS

More information

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate

More information

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION Hoepage > Products > Sound attenuators > Circular silencers > Type CF Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION Circular silencers, in flexible aluiniu construction,

More information

V-2410 Three-Way Multipurpose Solenoid Air Valve

V-2410 Three-Way Multipurpose Solenoid Air Valve 24-7040- 7, Rev. D V-2410 Three-Way Multipurpose Solenoid Air Valve Product Bulletin V-2410 Issue Date March 2016 Features Compact Size with Durable, Solid Brass Construction Can Be Mounted in Any Position

More information

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers Type volume flow controllers series volume flow controllers General information Correct use Safety notes Area of application Operating modes Product description Installation Commissioning and wiring 5

More information

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400 Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate

More information

Sensor systems. Type Differential pressure transducer. For the differential pressure recording and control in combination with EASYLAB.

Sensor systems. Type Differential pressure transducer. For the differential pressure recording and control in combination with EASYLAB. X X testregistrierung Sensor systems Type Differential pressure transducer For the differential pressure recording and control in combination with EASYLAB s based on the static measurement principle for

More information

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω

Power consuption Motor (Motion) Power consuption Standby (end position) 0(2)...10 VDC / Ri > 50 kω 0(4)...20 ma / Rext.= 500 Ω Actuators Technical data sheet Rotary actuator for control of volumetric flow without spring return Description Actuator for Volumetric flow and pressure control. Torque Motor Nominal Voltage Control Pressure

More information

TM-11x1 Series Room Temperature Module

TM-11x1 Series Room Temperature Module 24-10225- 4, Rev. C TM-11x1 Series Installation Instructions Part No. 24-10225-4, Rev. C Issued March 16 Applications The TM-11x1 Series of s are designed for use with the TC-9102 Direct Digital Control

More information

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Ceiling swirl diffusers with perforated face plate > Type DCS Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION

More information

HBO Range Gamme HBO. Hall effect open-loop current sensors. Capteurs de courant à effet Hall boucle-ouverte. Technical argumentation

HBO Range Gamme HBO. Hall effect open-loop current sensors. Capteurs de courant à effet Hall boucle-ouverte. Technical argumentation Technical argumentation Argumentation technique HBO Range Gamme HBO 1SBC146155D1701 Argumentation technique Gamme HBO1.1 - Version 1.1 Hall effect open-loop current sensors Capteurs de courant à effet

More information

CSD Series Current Devices Split Core

CSD Series Current Devices Split Core CSD Series Current Devices Split Core Installation Instructions CSD-CF0A0-1 CSD-CF0J0-1 CSD-CA1G0-1 Part. 24-10345-34, Rev. D Issued March 31, 2014 Supersedes April 5, 2013 Applications The Current Switch

More information

M9300 Series Potentiometer Kits

M9300 Series Potentiometer Kits M9300 Series Potentiometer Kits Installation Instructions M9300-140, M9300-1K, M9300-2K, M9300-10K 34-636- 2480, Rev. C (barcode for factory use only) Part No. 34-636-2480, Rev. C Issued June 2017 Application

More information

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES Prefilters or final filters for the separation of fine dust, or particulate filters for the most critical requirements in ventilation systems Filter

More information

Multileaf damper with actuator

Multileaf damper with actuator JZ Multileaf damper with actuator FOR SHUTTING OFF THE AIRFLOW IN AIR CONDITIONING SYSTEMS Rectangular multileaf dampers for volume flow and pressure control as well as for shutting off ducts and openings

More information

ThermaWall 2600 Primary components - back sections Composantes principales - traverses ou meneaux

ThermaWall 2600 Primary components - back sections Composantes principales - traverses ou meneaux Primary components - back sections Composantes principales - traverses ou meneaux CAPPED DOUBLE GLAZED SYSTEM MULLIONS MENEAUX DU SYSTÈME À COUVERCLES À ENCLENCHEMENT ET À DOUBLE VITRAGE 25759 25754 25774

More information

VA9905 Actuator and VG1600 Series Six-Way Valves

VA9905 Actuator and VG1600 Series Six-Way Valves VA9905 Actuator and VG1600 Series Six-Way Valves Installation Instructions *148836003206A* Contents Compliance Information...1 About This Document...1 Accessories...1 Support Information...1 Parts Included...2

More information

VA-4233-AGx Series Electric Valve Actuators

VA-4233-AGx Series Electric Valve Actuators Installation Instructions VA-4233 No. 1 Issue Date June 30, 2014 VA-4233-AGx Series Electric Valve Actuators Installation Refer to Figures 2 through 4 for proper actuator orientation before attempting

More information

3RB12. Betriebsanleitung Instructions. Bestell-Nr./Order No.: 3ZX1012-0RB12-1AA1 Ausgabe/Edition 01/2003. GWA 4NEB a

3RB12. Betriebsanleitung Instructions. Bestell-Nr./Order No.: 3ZX1012-0RB12-1AA1 Ausgabe/Edition 01/2003. GWA 4NEB a Elektronisches Überlastrelais Solid-state overload relay Relais de surcharge electronique Relé electronico di sobrecarga Relè elettronico di sovraccarica Elektroniska överlastrelä 3RB12 Betriebsanleitung

More information

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1 X X testregistrierung VAV terminal units Type Easy controller Compact controller Rectangular connection on the room end Circular connection on the fan end For supply air systems with demanding acoustic

More information

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators 34-636- 1360, Rev. C Installation Instructions M9109-GGx-5 Issue Date March 2016 M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators Installation IMPORTANT: Use this M9109-GGx-5 Series

More information

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

4/3 proportional directional control valve, without position control, with on-board electronics (OBE) 4/3 proportional directional control valve, without position control, with on-board electronics (OBE) Type 4WRBAE..E.. /..W.. Nominal size (NG) 6, 10 Unit series 2X Maximum working pressure P, A, B 315

More information

Index. ThermaWall Thermally broken curtain wall - Capped and SSG 2 1 2"(63.5mm) profile SSG. Capped

Index. ThermaWall Thermally broken curtain wall - Capped and SSG 2 1 2(63.5mm) profile SSG. Capped Thermally broken curtain wall - Capped and SSG 2 2"(63.5mm) profile Mur-rideau à bris thermique - Système VSS ou couvercles à enclenchement. Profilé de 2 2"(63.5mm) Index Capped Couvercles à enclenchement

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage AC/DC

More information

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch echnical data sheet actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx 4 m 2 orque 20 m ominal voltage AC/DC

More information

VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications

VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications VAV - A (High-speed variable volume flow ) Controls For Laboratories and Industrial Applications 1 2 3 4 5 6 7 8 Technical data sheet 227CS-024-08-V Actuator without spring return for flow- or pressure

More information

RedBin-P Pressure switches 5 Pa Pa

RedBin-P Pressure switches 5 Pa Pa RedBin-P Pressure switches 5 Pa... 5.000 Pa Electrical, explosion-proof binary pressure / differential pressure switches 5 Pa...100 Pa with adjustable switch activation delay 24 VAC/DC supply voltage,

More information

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology VALVE CONTROLLERS Controllers for Dust Extraction 2010 Technology / 2011 Valve controllers for all cases HESCH has the skills and technology to tackle any control task for dedusting of filter and dust

More information

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION Hoepage > Products > Airflow Control - VAV and CAV > Variable air volue flow control - VARYCONTROL > Secondary silencer > Type CA Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET

More information

M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators 34-636- 1484, Rev. B Installation Instructions M9109-GGx-4 Issue Date March 2016 M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators Installation IMPORTANT: The M9109-GGx-4 Series Electric

More information

M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators 34-636- 1468, Rev. B Installation Instructions M9106-GGx-4 Issue Date March 2016 Installation IMPORTANT: The M9106-GGx-4 Electric Actuator

More information

ALTI-NEXIS V OPERATING LIMITS APPLICATIONS ADVANTAGES. Flow rates up to: 320 m 3 /h Delivery head up to: Maximum operating pressure:

ALTI-NEXIS V OPERATING LIMITS APPLICATIONS ADVANTAGES. Flow rates up to: 320 m 3 /h Delivery head up to: Maximum operating pressure: OPERATING LIMITS Flow rates up to: 32 m 3 /h Delivery head up to: Maximum operating pressure: 24 m CE* 16 bar option 25 bar* Maximum water temperature: 7 C Ambient temperature: 4 C DN threaded manifold:

More information

UHC-202 Hardware Guide

UHC-202 Hardware Guide R Description The UHC202 is a fullyintegrated VAV terminal unit controller, complete with differential pressure sensor and integral Belimo LM24M zone damper motor. The UHC202 is designed for singlebox

More information

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit TRMUNV065ECxyyZ TRAUNV065ECxyyZ Installation Instructions subject to change without notice. Page 1 of 8 1.0 INSTALLATION WARNINGS 1. 2. 3. 4. 5. 6. "THIS

More information

M9109 Series Electric Non-spring Return Actuators

M9109 Series Electric Non-spring Return Actuators 34-636- 1190, Rev. D Installation Instructions M9109 Issue Date 03/1/16 M9109 Series Electric Non-spring Return Actuators Installation IMPORTANT: Use this M9109 Series actuator only to control equipment

More information

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE) Servo solenoid valves with on-board electronics (OBE) RE 29077/01.05 1/16 Replaces: 01.03 Type 4WRVE10...25 Size 10, 16, 25 Unit series 2X Maximum working pressure P, A, B 350 bar, T, X, Y 250 bar Nominal

More information

M9104-AGP-2S Series Electric Non-Spring Return Actuator with Pressure Sensor for VAV Applications Part No , Rev. B

M9104-AGP-2S Series Electric Non-Spring Return Actuator with Pressure Sensor for VAV Applications Part No , Rev. B 34-636- 2383, Rev. B M9104-AGP-2S Series Electric Non-Spring Return Actuator with Pressure Sensor for VAV Applications Part No. 34-636-2383, Rev. B Issued March 2016 Applications The M9104-AGP-2S Series

More information

COMMISSION INTERNATIONALE DE KARTING - FIA

COMMISSION INTERNATIONALE DE KARTING - FIA FICHE D HOMOLOGATION HOMOLOGATION FORM Homologation N COMMISSION INTERNATIONALE DE KARTING - FIA MOTEUR / ENGINE KF2 Constructeur Manufacturer OTK-KART-GROUP S.R.L.-(ITALY) Marque Make VORTEX Modèle Model

More information

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Homepage > Producten > Luchtroosters > Lijnroosters > Pureline18 PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet FA actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage

More information

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return echnical data sheet FA-S2 actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage

More information

M9102-AGA-3S and M9104-xGA-3S Series Electric Non-Spring Return Actuators

M9102-AGA-3S and M9104-xGA-3S Series Electric Non-Spring Return Actuators *346361433K* 34-636-1433, Rev.K M9102-AGA-3S and M9104-xGA-3S Series Electric Non-Spring Return Actuators Installation Instructions Part No. 34-636-1433, Rev. K Issued October 2017 Applications The M9102

More information

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer RE 29076/12.05 1/24 Type 4WRBKE Nominal size (NG) 10, 16, 27, 35 Unit series 1X

More information

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1. X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off

More information

RVP-R- VAV controller. In explosion-proof version

RVP-R- VAV controller. In explosion-proof version VAV controller In explosion-proof version RVP-R- SMAY LLC / 29 Ciep³ownicza St. / 31-587 Cracow / Poland tel. +48 12 378 18 00 / fax. +48 12 378 18 88 / e-mail: info@smay.eu Intended use VAV control units

More information

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback RE 29159/07.05 1/10 Type DBEBE6X Nominal size 6 Unit series 1X Maximum working pressure P 315 bar,

More information

Plan de présentation CSITC RT

Plan de présentation CSITC RT Explication du test interlaboratoires international du CSITC Dernières évolutions et Démarche qualité du LTC Jean-Paul GOURLOT Formation en technologie cotonnière Afrique Francophone du 14 au 25/10/2013

More information

M9300 Series Electric Non-Spring Return Actuators

M9300 Series Electric Non-Spring Return Actuators M9300 Series Electric Non-Spring Return Actuators Product Bulletin M9308-AGA-2Z, M9308-AUA-2Z, M9310-AUA-2, M9310-HGA-2, M9320-AUA-2, M9320-HGA-2, M9335-AUA-2, M9335-HGA-2 The M9300 Series Electric Non-Spring

More information

M9300 Series Switch Kits

M9300 Series Switch Kits M9300 Series Switch Kits Installation Instructions M9300-1, M9300-2 34-636- 2472, Rev. C (barcode for factory use only) Part No. 34-636-2472, Rev. C Issued June 2017 Application Requirements Refer to the

More information

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated RE 29216/09.05 1/18 Type FESE Nominal size 16, 25, 32, 40, 50 Unit series 1 Maximum

More information

Solid Clamps Raccords orientables

Solid Clamps Raccords orientables Solid Clamps Raccords orientables Versions: Raccords orientables Éléments monoblocs Pour un montage plus rapide et économique Série industrie Fonte d aluminium Grande diversité Éléments monoblocs Éléments

More information

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE) Servo solenoid valves with on-board electronics (OBE) RE 29037/10.05 Replaces: 01.05 1/12 Type 4WRPEH 10 Size 10 Unit series 2X Maximum working pressure P, A, B 315 bar, T 250 bar Nominal flow rate 50...100

More information

Parent s Guide. This guide contains important information. Please keep it for future reference US

Parent s Guide. This guide contains important information. Please keep it for future reference US Parent s Guide This guide contains important information. Please keep it for future reference. 91-003324-000 US INTRODUCTION The Stack & Tumble Elephant TM provides a silly twist on the classic ring stacker.

More information

Vannes à commande pneumatique pneumatically piloted valves

Vannes à commande pneumatique pneumatically piloted valves Vannes à commande pneumatique Distributeurs 3/2-5/2-5/3 avec raccordements G1/8 -G1/4 -G3/8 -G1/2 3/2-5/2-5/3 spool valves with G1/8 -G1/4 -G3/8 -G1/2 threaded ports Montage en ligne sur embases multiples

More information

INSTALLATION INSTRUCTION Bollard Light 12V

INSTALLATION INSTRUCTION Bollard Light 12V Bollard Light 12V 6611/6621/6631/6641/6651 SAFETY INSTRUCTION IMPORTANT: NEVER attempt any work without shutting off the electricity. Read all instructions before installing. System is intended for installation

More information

FITTING INSTRUCTIONS FOR CP0404BL/WH NO-CUT AERO CRASH PROTECTORS HUSQVARNA 701 ENDURO/SUPERMOTO 2016-

FITTING INSTRUCTIONS FOR CP0404BL/WH NO-CUT AERO CRASH PROTECTORS HUSQVARNA 701 ENDURO/SUPERMOTO 2016- FITTING INSTRUCTIONS FOR BL/WH NO-CUT AERO CRASH PROTECTORS HUSQVARNA 701 ENDURO/SUPERMOTO 2016- Page 1 PICTURE A PICTURE B REAR OF BIKE FRONT OF BIKE PICTURE C THIS KIT CONTAINS THE ITEMS PICTURED AND

More information

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE) Servo solenoid valves with on-board electronics (OBE) RE 29088/01.05 1/18 Replaces: 05.04 Type 4WRLE10...35, symbols V/V1 Size 10, 16, 25, 35 Unit series 3X Maximum working pressure P, A, B 350 bar, T,

More information

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of spring return actuator Description Spring-return actuator for adjusting and regulating dampers and valves in air conditioning and ventilation. Torque

More information

RedCos-P Pressure sensor 20 Pa Pa

RedCos-P Pressure sensor 20 Pa Pa RedCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical, explosion-proof pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue output EC type-approved in acc. with ATEX

More information

M9203-AGx-2(Z) Series On/Off and Floating Point Electric Spring Return Actuators

M9203-AGx-2(Z) Series On/Off and Floating Point Electric Spring Return Actuators M9203-AGx-2(Z) Series On/Off and Floating Point Electric Spring Return Actuators Installation Instructions M9203-AGA-2, M9203-AGB-2, M9203-AGA-2Z, M9203-AGB-2Z Applications The M9203-AGx-2(Z) Series On/Off

More information

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback Type DREBE6X Nominal size (NG) 6 Unit series 1X Maximum working pressure P 315 bar, T 250 bar

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV

More information

Fan Relay Board (FRBii) Assembly

Fan Relay Board (FRBii) Assembly Fan Relay Board (FRBii) Assembly Installation, Operation, and Maintenance Instructions PK-FCU030-0, PK-FCU050-0 Part No. 24-10143-1221, Rev. A Issued February 2017 Application Refer to the QuickLIT website

More information

Specification Grade Contemporary Wall Mount/Technical Installation Data

Specification Grade Contemporary Wall Mount/Technical Installation Data AVAILABLE CONFIGURATIONS RECESSED MOUNT SURFACE MOUNT MOUNTING REQUIREMENTS A. Recessed Mount: Minimum 4-Gang Box, 1-5/8 in. Deep (72.8 Cubic Inches) with 4-Gang Box Cover (20.3 Cubic Inches) B. Surface

More information

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air 5/9.2/EN/6 Volume Flow Limiter Type VFL for insertion into air ducting The art of handling air Contents Description 3 Dimensions 3 Nomenclature 4 Technical data 4 Acoustic data 4 Installation notes 5 Order

More information