Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX
|
|
- Henry Watkins
- 6 years ago
- Views:
Transcription
1 Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX Type TX FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS TYPE TVJ, OR EN Rectangular secondary silencers for the reduction of air-regenerated noise of air terminal units Type TVJ, or EN Absorption material is non-combustible mineral wool with RAL quality mark, biosoluble and hence hygienically safe according to the German TRGS 905 (Technical Rules for Hazardous Substances) and EU directive 97/69/EG Mineral wool faced with glass fibre fabric as protection against erosion due to airflow velocities up to 0 m/s Insertion loss measured according to ISO 735 Casing air leakage to EN 1577, class A APPLICATION Application Secondary silencer Type TX to reduce the air-regenerated noise of air terminal units For air terminal units TVJ and, and for mechanical self-powered controllers EN Nominal sizes 43 nominal sizes from to DESCRIPTION Parts and characteristics Casing Sound attenuator splitters without resonating panels Construction features Absorption sound attenuator without resonating panels
2 Rectangular casing Connection on the room end suitable for 30 mm air duct profiles Splitters with aerodynamically profiled frames Maximum splitter thickness 100 mm Splitter arrangement and number depends on the nominal size 50 % free area for all nominal sizes Materials and surfaces Casing and splitter frames made of galvanised sheet steel Absorption material is mineral wool Mineral wool To EN 13501, fire rating class A1, non-combustible RAL quality mark RAL-GZ 388 Biosoluble and hence hygienically safe according to the German TRGS 905 (Technical Rules for Hazardous Substances) and EU directive 97/69/EG Faced with glass fibre fabric as protection against erosion through airflow velocities of up to 0 m/s Inert to fungal and bacterial growth Standards and guidelines Casing air leakage to EN 1577, class A Maintenance Maintenance-free as construction and materials are not subject to wear TECHNICAL INFORMATION Specification text, Order code, Produktbeziehungen
3 SPECIFICATION TEXT Rectangular secondary silencers for VAV terminal units to reduce the air-regenerated noise, available in 43 nominal sizes Insertion loss at least 9 db at 50 Hz Splitters with aerodynamically profiled frames. Connecting flanges on both ends, suitable for 30 mm duct connection Casing air leakage to EN 1577, class A. Complies with VDI 083, clean room class 3, and US standard 09E, class 100. Materials and surfaces Casing and splitter frames made of galvanised sheet steel Absorption material is mineral wool Mineral wool To EN 13501, fire rating class A1, non-combustible RAL quality mark RAL-GZ 388 Biosoluble and hence hygienically safe according to the German TRGS 905 (Technical Rules for Hazardous Substances) and EU directive 97/69/EG Faced with glass fibre fabric as protection against erosion through airflow velocities of up to 0 m/s Inert to fungal and bacterial growth
4 ORDER CODE Order example: TX/ Nominal size (B H) mm Type Nominal size [mm] TX Secondary B H silencer Dimensions and weight, Product details Attachments: VARYCONTROL control components
5 Controlled variable Interface V min -/ V max - adjustment Differential pressure transducer Actuator Manufacturer Easy controller Dynamic Easy V Integral Integral 1 Compact controller Dynamic BC0 V MP bus Integral Integral BF0 V MP bus Integral Integral BL0 V LonWorks Integral Integral BM0 V Modbus Integral Integral BM0- J6 V Modbus and plug-in connecting cable Integral Integral XG0 V Integral Integral 3 XB0 V Integral Integral 3 LN0 V Integral Integral 5 LK0 V KNX 5 LY0 V Integral Integral 5 Compact controller Static SA0 V Integral Integral 4 SC0 Δp Integral Fast-running actuator, integral 4 Universal controller Dynamic B11 V Integral
6 B13 V Integral Actuator B7 V Integral Actuator B1B V Integral Spring return actuator XC3 V Integral Spring return actuator 3 Universal controller Static BP1 V MP bus Separate part BP3 V MP bus Separate part Actuator BPB V MP bus Separate part Spring return actuator BPG V MP bus Separate part Fast-running actuator BB1 V Separate part BB3 V Separate part Actuator BBB V Separate part Spring return actuator XD1 V Integral Actuator 3 XD3 V Integral Spring return actuator 3 BR1 Δp MP bus 100 Pa BR3 Δp MP bus 100 Pa Actuator BRB Δp MP bus 100 Pa Spring return actuator BRG Δp MP bus 100 Pa Fast-running actuator BS1 Δp MP bus 600 Pa
7 BS3 Δp MP bus 600 Pa Actuator BSB Δp MP bus 600 Pa Spring return actuator BSG Δp MP bus 600 Pa Fast-running actuator BG1 Δp 100 Pa BG3 Δp 100 Pa Actuator BGB Δp 100 Pa Spring return actuator BH1 Δp 600 Pa BH3 Δp 600 Pa Actuator BHB Δp 600 Pa Spring return actuator XE1 Δp Integral, 100 Pa Actuator 3 XE3 Δp Integral, 100 Pa Spring return actuator 3 XF1 Δp Integral, 600 Pa Actuator 3 XF3 XF3 XF3 XF3
8 XF3 XF3 1 TROX, TROX/Belimo, 3 TROX/Gruner, 4 Sauter, 5 Siemens order code detail, V volume flow rate, Δp differential pressure DIMENSIONS AND WEIGHT Nominal size CA-050 CA-100 ØD 3 ØD 3 mm mm ØD mm Nominal size B mm H mm B 1 B H 1 H mm mm mm mm m kg
9 Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX Home Contacts Imprint Delivery and payment terms Privacy Disclaimer TROX INDIA PRIVATE LIMITED
10 Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX TX 1 End facing the terminal unit End facing the room 3 Splitter section 4 Non-active section Home Contacts Imprint Delivery and payment terms Privacy Disclaimer TROX INDIA PRIVATE LIMITED
11 Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX PRODUCT DETAILS Detail of flange 1 Flange Compressible seal, to be provided by others Installation details, Basic information and nomenclature INSTALLATION DETAILS Installation and commissioning Air duct profiles fit air terminal units TVJ and, and mechanical self-powered controllers EN Connect the non-active section of the secondary silencer to the VAV terminal unit Home Contacts Imprint Delivery and payment terms Privacy Disclaimer TROX INDIA PRIVATE LIMITED
12 Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX TROX INDIA PRIVATE LIMITED Online-Services Your contact partner Online fault report Locations India Service-Hotlines Main Office Phone: +91 (0) Fax: +91 (0) TROX India Pvt Ltd. Unit No. 751, 5th Floor, Bldg. No. 7, Solitaire Corporate Park, Andheri (E), Mumbai Phone: +91 (0) Fax: +91 (0) Home Contacts Imprint Delivery and payment terms Privacy Disclaimer TROX INDIA PRIVATE LIMITED
Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX
Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX Type TX FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS TYPE TVJ, OR EN Rectangular secondary silencers
More informationParts and characteristics
Type TVZ FOR SUPPLY AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Highly
More informationType TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES
Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Rectangular VAV terminal units for the extract air control in buildings with variable air volume
More informationVAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K
. X X testregistrierung VAV terminal units Type Easy controller Compact controller Circular connection on the fan end For extract air systems with demanding acoustic requi rements VAV terminal units for
More informationVAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1
X X testregistrierung VAV terminal units Type Easy controller Compact controller Rectangular connection on the room end Circular connection on the fan end For supply air systems with demanding acoustic
More informationType TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES
Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Rectangular VAV terminal units for the extract air control in buildings with variable air volume
More informationVAV terminal units. Type TVM. For dual duct systems PD TVM 1
X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings
More informationType RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW
Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate
More informationType TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF
Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF Rectangular VAV terminal units for standard applications regarding the supply air or extract air control in variable air volume
More informationHomepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR
Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Circular VAV terminal units for standard
More informationType MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE
Homepage > Products > Sound attenuators > Splitter sound attenuators > Type MSA Type MSA Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE
More informationHomepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN.
Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN Type EN FOR THE PRECISE CONTROL OF NORMAL AND HIGH CONSTANT VOLUME FLOWS
More informationType TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements
Type TVZ FOR SUPPLY AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Highly
More informationType TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS
Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the extract air control in buildings with variable air volume systems and demanding acoustic requirements Highly
More informationType CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION
Homepage > Products > Sound attenuators > Circular silencers > Type CS Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION Circular silencers, in rigid aluminium construction,
More informationType TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS
Homepage > Products > Control Systems > Variable volume flow control > VAV terminal units > Type TVLK Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS Plastic circular VAV terminal units
More informationCircular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1
X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, galvanised sheet steel construction Circular silencers Type for the reduction of noise in the circular ducts
More informationType TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS
Home > PRODOTTI > Unità di regolazione > VARYCONTROL > Unità terminali VAV > Serie TVA Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the extract air control
More informationType DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES
Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Ceiling swirl diffusers with perforated face plate > Type DCS Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION
More informationType CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION
Hoepage > Products > Airflow Control - VAV and CAV > Variable air volue flow control - VARYCONTROL > Secondary silencer > Type CA Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET
More informationCircular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en
X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, aluminium construction Circular silencers, in rigid aluminium construction, for the reduction of noise in the
More informationType RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW
Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate
More informationType TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES
Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Circular VAV terminal units for standard applications regarding the supply air or extract air control in variable air
More informationType CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION
Hoepage > Products > Sound attenuators > Circular silencers > Type CA Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION Circular silencers Type CA for the reduction
More informationCAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1
X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air
More informationRN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400
Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate
More informationCeiling swirl diffusers with perforated face plate
X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser
More informationCAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1
X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air
More informationType VSD35. Nominal length up to 1500 mm: one spigot
Type VSD35 Nominal length up to 1500 mm: one spigot NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with 35 mm diffuser face (nominal width) and adjustable air control elements
More informationCAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)
X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered
More informationPURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS
Homepage > Producten > Luchtroosters > Lijnroosters > Pureline18 PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with
More informationCONSTANTFLOW Volume Flow Controllers
5/9.1/EN/8 CONSTANTFLOW Volume Flow Controllers for constant volume systems Type EN The art of handling air Contents Description Description 2 Application 3 Construction Dimensions Accessories 4 Dimensions
More informationCAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1
X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered
More informationType CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION
Hoepage > Products > Sound attenuators > Circular silencers > Type CF Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION Circular silencers, in flexible aluiniu construction,
More informationType AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK
Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK Type AKK FOR CONTAMINATED AIR Plastic circular shut-off dampers for shutting off aggressive
More informationType AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK
Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK Type AK FOR LOW-LEAKAGE SHUT-OFF Circular shut-off dampers for shutting off volume flows in ventilation ducts
More informationCAV controllers Type RN
2.1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or return air in constant
More informationHomepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.
Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL Type KUL FOR INSTALLATION INTO DUCTWORK Non-return dampers prevent unwanted airflows
More informationType AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)
Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK-Ex Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Circular shut-off
More informationSlot diffusers for ceiling installation
X X testregistrierung Slot diffusers for ceiling installation Type lenum box with damper blade (optional) Alternating horizontal air discharge Concealed screw fixing With wide diffuser face for larger
More informationVARYCONTROL VAV Dual Duct Terminal Boxes
5/2/B/3 VARYCONTROL VAV Dual Duct Terminal Boxes for variable volume systems Type TVM Trox (U.K.) Ltd Caxton Way GB-Thetford Norfolk IP24 3SQ Telephone +44 (0)1842 754545 Telefax +44 (0)1842 7051 www.troxuk.co.uk
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV
More informationCircular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/
6/5/EN/6 Circular Silencer Rigid and flexible construction Type CA CB CF CS TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn
More informationType KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU
Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS Rectangular fire damper for use in extract air and exhaust air ducts of
More informationType VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL
Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES Circular ceiling swirl diffusers, with manual or motorised adjustment of the
More informationType ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES
Homepage > Products > Air Diffusers > Industrial diffusers > Diffusers for high momentum > Type ISH Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES Impulse diffusers with horizontal air discharge
More informationShut-off dampers. Type AKK. For contaminated air PD AKK 1
X X testregistrierung Shut-off dampers Type Variant with circular spigot For contaminated air Plastic circular shut-off dampers for shutting off aggressive media volume flows in air conditioning systems
More informationType NAK. Gas-tight shut-off damper with pneumatic actuator
Homepage > Products > Control units > Shut-Off dampers > Type NAK Type NAK FOR THE GAS-TIGHT SHUT-OFF OF DUCTS Gas-tight shut-off damper with pneumatic actuator Gas-tight shut-off dampers are designed
More informationType WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES
Homepage > Products > External Louvres & Dampers > External weather louvres > External weather louvres > Type WG Type WG External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS,
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1
X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationHeat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en
X X testregistrierung Heat exchanger Type For the reheating of airflows in circular ducting Circular hot water heat exchanger for the reheating of airflows, suitable for VAV terminal units Type TVR and
More informationMultileaf damper with actuator
JZ Multileaf damper with actuator FOR SHUTTING OFF THE AIRFLOW IN AIR CONDITIONING SYSTEMS Rectangular multileaf dampers for volume flow and pressure control as well as for shutting off ducts and openings
More informationVAV Terminal Units SDS
VAV Terminal Units SDS VAV Terminal Units SDS STEKON SDS; controls the volume of conditioned air into an occupied space in response to a thermostat or Building Management System control signal with minimal
More informationCAV controllers. Type VFL. Volume flow limiter for insertion into ducting K
.1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical
More informationTYPE EK-EU SMOKE CONTROL DAMPER
Homepage > PRODUCTS > Fire and Smoke Protection > Smoke Control Damper > Type EK-EU TYPE EK-EU SMOKE CONTROL DAMPER WITH TROXNETCOM AS AN OPTION CE COMPLIANT ACCORDING TO EUROPEAN REGULATIONS EK-EU WITH
More informationFor installation into ductwork
X X testregistrierung Non-return dampers Type For installation into ductwork Non-return dampers prevent unwanted airflows against the intended airflow direction when the system is not in operation Maximum
More informationType JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS
Homepage > Products > External Louvres & Dampers > Multileaf dampers > Multileaf dampers > Type JZ Low leakage Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS Rectangular multileaf
More informationHomepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM
Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM MULTI-SERVICE ACTIVE CHILLED BEAM WITH TWO-WAY AIR DISCHARGE AND HORIZONTAL
More informationJVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6
1 CONTENTS Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6 2 VAV regulator, model Description The variable air volume regulators
More informationShut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.
X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off
More informationTechnical documentation
VM-PRO Mechanical volumetric flow control- Table of Contents Areas of application... 2 Useable volumetric flow ranges... 2 Function... 3 Processing... 3 Available sizes / -dimensions... 4 Accessories list
More informationCeiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades
X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling
More information4/S6 VAV DAMPERS RVP-C, RVP-P, RVK RVP-C-T, RVP-P-T. v 2.5 (en)
4/S6 v 2.5 (en) VAV DAMPERS RVP-C, RVP-P, RVK RVP-C-T, RVP-P-T www.klimaoprema.hr 253 TABLE OF CONTENTS Variable air volume control damper - round... 255 Variable air volume control damper - rectangular...
More informationType MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES
Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES Prefilters or final filters for the separation of fine dust, or particulate filters for the most critical requirements in ventilation systems Filter
More informationDisc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1
X X testregistrierung Disc valves Type For supply air Circular disc valves with manually adjustable annular gap Nominal sizes 100, 125, 160, 200 mm Volume flow rate range 10 90 l/s or 36 324 m³/h Diffuser
More informationControl units. Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL
Control units Simple. Precise. Efficient. Control units LVC, TZ-/TA-Silenzio and VFL The art of handling air Ventilation and air conditioning systems must fulfil complex and demanding requirements. With
More information[Y] Acoustic Splitters with spigot ends/aerodynamically shapped for energy saving (Pressure drop reduction 25% to 30%)
SLK series Splitter Attenuators Rectangular duct attenuator constructed from galvanised sheet steel, with splitter type acoustic elements. Provided with 20, 30 or 40 mm profile flanges, which are compatible
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Grille cores made of aluminium, with fixed horizontal blades Grille cores with special profiled blades
More informationCeiling swirl diffusers with perforated face plate
X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge For horizontal swirling supply air discharge creating high induction levels, with fixed air
More informationVAV controller. TROX Auranor Norge AS. Telephone Fax
GB0814 11.18 LØV-R VAV controller New regulator handles larger working area Low noise level Pressure independent Short overall length High measurement accuracy Can be installed directly in bend Flexible
More informationTROX Prisliste Regulatorer K5-00
TROX Prisliste 2019 Regulatorer K5-00 K1 - ARMATURER, RISTE Ceiling swirl diffusers AIRNAMIC...7 VDW...8 TDV-SilentAIR...9 RFD...10 FD...11 TDF-SilentAIR...12 VD...13 VDL...14 FDE...16 Design ceiling swirl
More informationThe Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans
Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular
More informationVAV TERMINAL BOXES TYPE: BA BT
Installation dimensions View inlet side View outlet side C G F E ø D A 65 ø8 B 25 Side view Top view 40 150 150 L1 Application ø D 150 Size operating range q (m 3 /h) Min. Max. Nom. 125 90 150-440 500
More informationPressure relief dampers
X X testregistrierung Pressure relief dampers Type Closed blade For the prevention of excess pressure in rooms Pressure relief dampers for gas fire extinguishing systems and transformer substations Air
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of sheet steel, with individually adjustable, horizontal blades Ventilation
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of aluminium, with fixed horizontal blades also for horizontal runs Single
More informationWaterside Fancoil Units
side Fancoil Units Type Horizontal chassis type waterside fancoils for concealed or exposed installations for cooling, heating and fresh air supply applications Nominal sizes 60, 90, 120, 150, 180 & 205
More informationWaterside Fancoil Units
side Fancoil Units Type Horizontal chassis type waterside fancoils for concealed or exposed installations side fancoil units for cooling, heating and fresh air supply applications Nominal sizes 60, 90,
More informationVentilation grilles for installation into walls, sills or rectangular
X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles with flat border construction also for continuous horizontal runs The new ventilation
More informationVAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD
VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD R CONTENTS MODEL: KYODO / KYODO-R... 1 INTRODUCTION... 1 APPLICATION... 1 VARIABLE AIR VOLUME SYSTEM... 1 FEATURES... 2 MATERIALS... 3 AIR VOLUME CONTROL
More informationHome > Products > Filter elements and filter units > Particulate filter air terminal devices > Pharmaceutical clean room terminal filters > Type TFP
Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION Pharmaceutical clean room terminal filters as final filter stage with Mini Pleat filter panels
More informationRECTANGULAR VAV DAMPER TECHNICAL CATALOGUE
RECTANGULAR VAV DAPER ERVA TECHNICAL CATALOGUE Rectangular VAV damper ERVA - Technical catalogue 2 KEY FEATURES Variable airflow Constant airflow Real-time airflow measurement with FläktGroup compact controller
More informationVolume Flow Limiters Type VFL
X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered
More informationPressure control damper ERPA
Key features Constant pressure Real-time pressure monitoring with FW compact controller Can be connected to Modbus Available in IPSUM compatible version ERPA is a rectangular pressure control damper for
More informationCeiling swirl diffusers
X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,
More informationTCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser
Halton TCM Conical Ceiling Diffuser Horizontal air supply, suitable also for exhaust Suitable for cooling applications with supply/room air temperature difference as low as -12 C Installation flush to
More informationType Pneumatic actuators
Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Pneumatic actuators Type Pneumatic actuators PNEUMATIC ACTUATORS FOR THE OPENING AND CLOSING OF DAMPERS IN AIR
More informationType Pneumatic actuators
Homepage > Products > External louvres - louvre blades > Multileaf dampers > Attachments > Type Pneumatic actuators Type Pneumatic actuators PNEUMATIC ACTUATORS FOR THE OPENING AND CLOSING OF DAMPERS IN
More informationDFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser
Halton DFB Conical Ceiling Diffuser Horizontal air supply, suitable also for exhaust Installation flush to the ceiling, light-weight aluminium design Circular duct connection with rubber gasket All sizes
More informationType TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION
Homepage > Prodotti > Elementi ed unità filtranti > Cassonetti terminali per l'alloggiamento di filtri a piccole pieghe > Terminali filtranti per camere bianche > Type TFP Type TFP FOR CRITICAL AIR CLEANLINESS
More informationto obtain the specified voids due
ARABIAN THERMAL AIRE INDUSTRIES NEW RANGE OF TESTED & CERTIFIED SOUND ATTENUATORS Arabian Thermal Aire Industries PO Box 1125, Jubail Industrial City, Saudi Arabia -319611 Tel: +966133415857 Fax: +9661334116311
More informationVAV terminal units VARYCONTROL. Installation and commissioning manual. GB/en. LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK
Installation and commissioning manual GB/en VAV terminal units VARYCONTROL LVC TVR TVJ TVT TZ-/TA-Silenzio TVZ TVA TVM TVRK TVLK Read the instructions prior to performing any task! TROX GmbH Heinrich-Trox-Platz
More informationTBV - Terminal Unit. Halton TBV. Terminal Unit
Halton TBV Terminal Unit Horizontal air supply, suitable also for exhaust Integrated rectangular balancing plenum with measurement and adjustment functions Effective sound attenuation Circular duct connection
More informationseries Silencers
series SK Silencers www.koolair.com Series SK 1 Silencers CONTENTS ASK-1 and ASK-2 Round Silencers Description 4 ASK-1 Overall Dimensions 5 ASK-2 Overall Dimensions 6 Selection Table and Weights 7 ASK-1
More informationMechanical mixing box MBM
Mechanical mixing box MBM Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Fax 0 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction... 3 Model...
More informationCADENZA. Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS
Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS Rectangular sound attenuator with connection to the outer casing, which also enables flange connection Excellent aerodynamic
More informationUTK/UTT - Multi-blade Damper. Halton UTK, UTT. Multi-blade Damper
Halton UTK, UTT Multi-blade Damper Temperature operation range up to +100 C, optionally up to +200 C Galvanised steel design Classification of casing leakage EN 1751 class B UTK: Shut-off, adjustment,
More informationFloor diffusers. The art of handling air. Type FB. In aluminium and plastic
T.3//EN/ Floor diffusers Type FB In aluminium and plastic The art of handling air Contents Description Description Installation examples 3 Construction Dimensions Plenum box Load capacity Installation
More informationTechnical Brochure. LTG Air Distribution. Variable flow rate controllers VRFactive. Rectangular, with LTG map control.
Technical Brochure LTG Air Distribution Variable flow rate controllers VRFactive Rectangular, with LTG map control www.ltg.net LTG Comfort Air Air-Water-Systems Air Diffusers Air Distribution Content Page
More information