CHAPTER 4 PITCH CONTROL OF WIND TURBINE GENERATORS

Size: px
Start display at page:

Download "CHAPTER 4 PITCH CONTROL OF WIND TURBINE GENERATORS"

Transcription

1 62 CHAPTER 4 PITCH CONTROL OF WIND TURBINE GENERATORS 4.1 INTRODUCTION The use of wind power has in the last decade increased in the central parts of Europe and at the west coast of the U.S. The rest of the world is following these and today this is the fastest growing energy source on a world basis. India has one of the fifth largest wind power installed capacity in the world. This chapter describes the modeling of the various components in a pitch controlled wind energy system. It also describes the design of the pitch controller and discusses the response of the pitchcontrolled system to wind velocity variations. The pitch control system is found to have a large output power variation and a large settling time. The pitch function gives full control over the mechanical power and if the most common method is used for the variable speed wind turbines. At wind speeds below the rated power of the generator, the pitch angle is at its maximum though it can be lower to help the turbine accelerate faster. Above the rated wind speed, the pitch angle is controlled to keep the generator power at rated power by reducing the angle of blades. The pitch control system is one of the most widely used control techniques to regulate the output power of a wind turbine generator. The method relies on the variation in the power captured by the turbine as the

2 63 pitch angle of the blades is changed. Hydraulic actuators are used to vary the pitch angle. The wind turbine generator describes the design of the pitch controller and discusses the performance of the system in the presence of disturbances. The control system consists of two controllers are inverter controller that keeps the load voltage constant and the pitch controller acting on the blades angle by using simulation. The variable speed induction generator using Volts/Hertz control enables efficient wind energy capture and is shown in Figure 4.1. The output of the generatorside converter can be varied to control the speed of the induction generator (Schians 2007). The gridside converter can be controlled to inject the desired power and reactive power into the grid. Thus, the wind system is capable of providing reactive power support, if required. The disadvantage of this configuration is the large cost associated with the power converter, since the converter has to be rated for the maximum power output of the generator. Figure 4.1 Volts / Hertz controlled induction generator

3 64 For fixed speed turbines, the active stall can be used to limit the power, not by reducing the pitch angle as in pitch controlled, but by increasing the pitch angle to a point where the blade stalls and in that way reduces the force on the turbine. By regulating, the angle to be on the limit of stalling, fast torque changes from the wind will be neutralized (Schinas et al 2007; Nayar and Bundell 1987). 4.2 PRINCIPLE OF CONTROL Aerodynamic Power Control for Wind Turbines When a generator reaches rated power, the turbines must limit the mechanical power delivered to the generator. This is valid because the generator reaches the rated power at for instance 15 m/s while the maximum speed is typically 25 m/s for a wind turbine. Control is done by three different methods called stall, pitch and a combination called active stall. There are no moving parts in the stallcontrolled blades and the challenge is in the construction of the blades to avoid vibration and make them stall gradually. The pitch angle is controlled to keep the generator power at rated power by reducing the angle of the blades. By regulating, the angle to be on the of stalling, fast torque changes from the wind will be reutilized (Nayar and Bundell 1987). The power captured by the turbine is given by Pm = Pw Cp

4 65 Figure 4.2 Airstreams around a turbine The mass flow rate is a constant for upstream (0), the rotor (1) and down stream (2) mass flow rate mass as shown in Figure 4.2. m= pav 0 0 = pav 1 1 = pav 2 2 (4.1) The turbine model represents the power captured by the turbine. The power in the wind (P w ) in an area A is given by, P w 1 3 = ρ AVw (4.2) 2 where ρ is the density of air and V w is the wind speed. However, the turbine captures only a fraction of this power. The power captured by the turbine (P m ) previously expressed as P m = P w C p, where C p is a fraction called the power coefficient. The power coefficient represents the fraction of the power in the wind captured by the turbine and has a theoretical maximum of The power coefficient can be expressed by a typical empirical formula as, Cp 1 2 ( γ 0.022β 5.6) 2 e 0.17 γ = (4.3)

5 66 The variation of C P with the pitch angle β for various values of the tip speed ratio γ. Thus, by varying the pitch angle, the power coefficient can be changed and the power captured by the turbine can be controlled. If the C p γ performance characteristic is available, the turbine parameters can also be modeled from data fields containing the group of curves derived from measurement or from calculation or analytical function. The groups of power coefficient and tip speed ratio curves obtained by measurement or by computation can also be approximated in closed form by nonlinear functions as shown in Figure 4.3. Figure 4.3 Power Coefficient vs tip speed ratio for various values of pitch angle Normal operation, blade pitch adjustments with rotational speeds are approximately expected at β n = 5 to 10 / S = 0.09 to 0.17 rad/sec (Siegfried 2006) Wind Turbine Controller The name of the controller for the wind turbine is the multi processor controller, which is an abbreviation of multi processor controller. The controller monitors and controls all functions in the turbine, in order to ensure that the performance of the turbine is optimal at any wind speed.

6 67 The control will stop the turbine if supervision detects an error. At an operator panel, data of current operation is displayed. The multi processor controller is divided in to two parts: 1. Ground controller and 2. Topcontroller. Ground processor takes care of cut in and cutout of the generator and the capacitors and of current and voltage measurement. Top processor takes care of the tasks in the nacelle, example: Speed, pitch and power control yawing and internal temperature control ( Data Collection The multi processor controller collects continuously data about the performance of the turbine example: Rotor and generator speed, Wind speed, Hydraulic pressure, Temperature, Power and energy production and Pitch. If some irregularities or errors arise, the data is stored in a LOG and/or an ALARM LOG, making it possible to analyze errors in the turbine System of Parameters The software to the MPcontroller system is basically constructed so that all variables can be initialized. Examples of parameters are power

7 68 reference, various alarm limits, calibration values for anemometer etc. To every type of turbine and variants, a set of parameters is present, which is selected by startup of the turbine Turbine Control with OptiTip When the turbine is stopped (PAUSE, STOP or EMERGENCY STOP), the blades will be present in a pitch angle of 90 (out of the wind), as shown in Figure 4.5. When the turbine is in RUNmode, it is able to produce electrical energy, but the momentary wind conditions are determining for how much. This is controlled by the OptiTip control system of the multi processor controller. The momentary wind conditions can be divided into four categories, shown by the power curve in Figure 4.4, Figure 4.4 Power Curve

8 69 1. Low wind, the generator is not connected to grid. 2. Medium wind, the generator is connected, but does not produce nominal power. 3. Higher wind, the generator is connected and produces nominal power. 4. Stop wind, the generator is disconnected and the turbine is stopped. When the wind is very low and the rotor does not rotate with a very low speed, the pitch angle will be approximately This will give maximum start moment to rotor, which gives a quicker start, when the wind increases. The MPcontroller will then pitch the blades to 0 (into the wind). The rotating speed for the rotor and the generator will increase towards the nominal, which the multi processor controllers will try to keep (speed control). The same situation occurs with connected generator. When the wind decreases and the produced power become negative, the generator will be disconnected from the grid and the MP controller will control the speed. If the wind decreases even more then the rotating speed will decrease below nominal value and the rotor will run freely. At medium wind speed, the rotating speed is regulating to the nominal value and if the pitch angle can be kept at 5 0 (which says that there would be enough energy in the wind), the generator is connected to the grid. With the generator connected and but enough energy in the wind to produce nominal power, the pitch angle is regulated as a function of the wind speed.

9 70 This function is calculated with precision, simulated and evaluated by measurements. It is called OptiTip. This is implemented in turbines to optimize the aerodynamics of the blades, which will optimize the energy production as shown in Figure 4.5. Figure 4.5 Pitch setting at different operating states When the generator is producing power, it causes a torque, in opposition to the mechanical torque of the rotor. The MPcontroller based fully automatic systems controls the produced powers, so the rotor speed is kept constant within a narrow band, which is called slip, which is the procentual relation between actual and

10 71 synchronous rotating speed and optimal adjustment of the angle of the blade in relation to the prevailing wind, thus generating maximum power. Such processes are currently used by machines in 30 KW to MW range that employ power electronics to convert the frequency to that required with their design in the limits, such models permit Power Factor Correction An asynchronous generator contains no permanent magnet and is not separately excited. That means, that an asynchronous generator has to get exciting current from the grid and the magnetic field is only established, when generator is connected to the grid. When the generator excites current from the grid, the generator consumes reactive power from the grid. The current in the cable to the generator will consist of two parts, 1. Active current corresponding to the active power production (KW) and 2. Reactive current corresponding to the reactive power consumption (KVAr). Because of the exciting current, there is a phase shift between the current and the voltage. The current delayed compared to the voltage by an angle (θ). A term of the phase shift is the power factor (cos θ). A part of the generator s exciting current / reactive power is delivered from the capacitors, which are called power factor correction. The capacitors are connected to the grid a little later than the generators are disconnected, before the generator is disconnected from the grid.

11 72 The advantage of the power factor correction is that the loss in the grid decreases, because the grid current decreases. At noload the grid current is about zero Amp, because the generator s noload current (only reactive current) is delivered from the capacitors. 4.3 PITCH CONTROL SYSTEM DESIGN Pitch control means that the blades can pivot upon their own longitudinal axis. The pitch control used for speed control, optimization of power production and to start and step the turbine. The control system structure used to generate the pitch angle reference is given in Figure 4.6 (Murdoch et al 1982). The pitch controller consists of two paths a nonlinear feed forward path, which generates β 0 and a linear feedback path, which generates β. Figure 4.6 Pitch angle reference generator The feed forward path uses the information about the desired power output, wind velocity and the turbine speed to determine the pitch angle required. Equation (4.4) gives the pitch angle as a function of the measured variables. 1 2Pref e β0 = γ Pw 0.17γ (4.4)

12 73 However, the feed forward term assumes that all the components are ideal and does not account for the losses in the system. The feedback path compensates for the losses by decreasing the pitch angle, if the output power is less than the desired power, to increase the power captured. The PI controller (Proportional integration) for the system is designed using the ZeiglerNicholas rules for tuning PID (Proportional integration and differentiation) controllers Zeigler Nicholas Rules The method used here is the first method applicable for plants without integrators or dominant complex conjugate poles, as the plant response for the wind system is found to correspond to these requirements of the ZeiglerNicholas rules. For a plant response to a unit step input as given in Figure 4.7, the intersection of the tangent line at the inflection point with the start and end values of the curve gives the delay time (L) and the time constant (T). Figure 4.7 Obtaining the time constant and delay time for a response to a unit step

13 74 For a controller of the type K P (1+1/T i s) The values of K P and T i are given as K P =0.9(T/L); T i =L/ PI Controller Design In order to use the ZeiglerNicholas rules for designing the PI controller, the step response of the plant is required. The block diagram showing the plant and controller used for generating the step response is shown in Figure 4.8. The actuator is modeled as an integrator in a feedback loop, as shown in Figure 4.9. The rate limiter limits the rate of change of the pitch angle, as most pitch actuators cannot change the pitch angle more than a particular degrees / sec. The value used for the rate limiter in the simulations is 5 0 / sec. Figure 4.8 Plant and controller definition

14 75 Figure 4.9 Hydraulic actuator model used in the simulation The unitstep response of the plant, obtained by applying a onedegree step input is shown in Figure 4.10 (Pena et al 1996). The measured values of the time delay L and the time constant T are, L = 0.03s and T = 0.155s. Thus, the values of the proportional and integral constants are, K P = 4.65 and K i = Figure 4.10 Plant response to a unit step input

15 76 The SIMULINK block diagram of the pitch controlled wind energy system is shown in Appendix A ANALYSIS OF FIELD TEST RESULTS Wind Shear Correction No correction needs to be applied to the wind speedreading for anemometer heights different from hub height Correction of Power for Air Density Variations Before data analysis using the method of bins is carried out, corrections to the data sets for air density variations must be applied. In this procedure, the wind speed range of operation of the wind turbine is divided into a series of intervals (bins). The aim of the corrections is to bring the power curve and the calculated mean power as close as possible to the values which would be obtained if the measurements were all carried out at a standard air density at sea level of Kg / m 3 ( mbar, dry air, degree Celsius or degrees Kelvin). For a stallcontrolled wind turbine, each 10 min average net power values shall be corrected by applying the following formula: [ ] P = P ρ (4.5) s T T where, P s = Power corrected to standard conditions, P T = Uncorrected average power, ρ T = Test air density and

16 77 P T is calculated from degrees Kelvin. [ ][ ] ρ T = T B (4.6) where, B T t = Barometric pressure, (mbar) = t and = Air temperature in degrees Celsius. For a pitchregulated WTG, the correction is the same as for a stall controlled WTG as long as the measured power levels are below 70 % of rated power. For measured power levels above 70 % of rated power, the correction applies instead to wind speed (and not to power) according to the following expression. V s t T [ 1.225] 1/3 = V ρ (4.7) where V t is the measured, uncorrected wind speed (m / s) and V s is the wind speed corrected to standard conditions. n i P = 1 n P (4.8) i i ij j= 1 where, V ij = j th 10 minute average of wind speed in the i th bin, P ij = j th 10 minute average of net power in the j th i th bin and n i = Number of data sets in the i th bin. The ensemble averages (V i, P i ) are then plotted and a curve fitted through the plotted points. This curve is the WT power curve. The minimum conditions of shorter preaveraging time does not reduce the total time, as the

17 78 number of data sets per bin multiplied by the pre averaging time shall be constant and must be met before the curve is established. The power curve is a linearly scaled Cartesian coordinate system graph of WT net power corrected for air density variations (ordinate) versus wind speed (abscissa) as shown in Figure Both scales start at zero. The ordinate scale should extend to at least 110 % of the WT maximum power. The abscissa should extend to a wind speed of at least 20 meters / second. The power curve is to be displayed graphically as indicated in Figure 4.11 and in form of a table as shown in Table 4.1. Care should be taken not to apply air density corrections to fractions of the power, which are not dependent on air density, such as gearbox and generator losses. Figure 4.11 Output power profile of the pitch controlled wind turbine generator

18 79 Table 4.1 The results of the method of bins analysis Bin no 1 Bin interval Number of datasets m/s n 1 speed V 2 Wind (m/s) Bin averages Net speed P 1 (kw) 6.22 Rotor speed (rpm) Nominally fixed speed If, for instance, the relation between net power P and rotor power P R is of the form P = αp R β (4.9) with α and β constant, then the correction of power for air density variations should be ( P ) P = ρ α β (4.10) s T R

19 80 This will be the case with gridconnected, constant speed WTG, where the electric losses normally will be proportional to the power produced, while the mechanical losses in the drive train will be rotor speed dependent and hence constant for a constant speed WTG. 4.5 RESULTS OF THE SIMULATION The power output of the pitchcontrolled wind turbine generator to the wind velocity variation of Figure 4.12, is shown in Figure The desired output power is 12 KW. The output power variation is large (12 %) and the settling time of the system is about 15 sec. The pitch angle reference generated by the pitch controller and the actual pitch angle of the blades (output of the actuator) are plotted in Figure The response of the pitch actuator is slow (the time constant is 1 second) and this limits the performance of the system. The plot of the rotor speed is shown in Figure The rotor speed is always above 1.0 p.u, indicating that the generator is operating at supersynchronous speeds and has pitch regulated rotor blades for high performance and for highly effective start and break. Figure 4.12 Wind speed profile used for simulation

20 81 Figure 4.13 Output power profile of the pitch controlled wind turbine generator Figure 4.14 Plots of the pitch angle reference and the output of the pitch actuator Figure 4.15 Rotor speed of the induction generator

21 THE MERITS OF PITCH REGULATED WIND ENERGY GENERATORS The two basic types of wind energy generators that have been installed in India are Pitchregulated and stallregulated. Pitchregulated Wind Energy Generator (WEG) is manifold. In Stallregulated WEG s as the blades are firmly connected to the rotor the flow over the profile of the blade is lost and less torque is produced on the rotor shaft thereby limiting the power output. From the Figure 4.16 can be seen that a Pitch Regulated WEG is preferable to a StallRegulated WEG. For a PitchRegulated WEG the generation even after reaching maximum remains constant when speed increases whereas in the StallRegulated WEG it starts to drop down. Figure 4.16 Comparison of Power Curves of PitchRegulated and Stall Regulated WEG

22 83 The Pitch Regulated WEG has the following additional merits. Stopping of Rotor: The Pitch system makes it possible to rotate the blades to a position, which stops and starts the rotor at any wind speed. Active Control: The Pitch system is useful for active regulation by which nominal power can always be reached. However, in stall regulated, power curve can be changed only by effecting a permanent change in blade angle. Speed: The Speed can be controlled prior to connecting the WEG to the grid. That is, the pitch control system facilitates rotation at proper speed for a longer period of time before connecting to the grid. Lower wind speeds: Even at lesser winds in PitchRegulated WEG s maximum torque is obtained and the rotor starts whereas in Stall Regulated WEG s higher wind speed is required, as the design is such. This in turn may lead to decrease in the lifetime of the electrical components. Power: The power can be limited at locations with a weak grid. The WEG can easily be regulated by the Pitch control system and there is no need to change the WEG design to produce less nominal power. Pitch Control System: The pitch control system is not significantly affected by the change in air density and change in temperature, about placement of the WEG s at certain heights above sea level. Maximum power production will be always be attained in a pitch controlled WEG while in a stall

23 84 controlled WEG it is poor when there is change in temperature or and when the blades are dirty. Calculation of Blade and Rotor Loads: In the case of Pitch Regulated WEG s the blades always experience laminar flow across the profile and turbulent, chaotic flow has no influence. This means that WEG loads in a Pitch Controlled WEG are determined in a more correct manner. Greater Flexibility: The PitchRegulated WEG can readily be transformed to other turbine by changing the Pitch control strategy and programming a different blade angle. Better test facilities: As the blade angle can be turned to, a welldefined position is easier; it is simulation of specific production or testing condition. Power optimization below nominal Power: The power is optimized by rotating the blade to an angle, which results in a better and optimized power production. This is done by the pitch control system, which could compare the power measured as a certain wind speed with a master curve and change the pitch angle accordingly. Blade geometry: It is possible to optimize blade geometry without worrying about power regulation and the same can only be done by a Pitch system and not by Stall. Greater Capacity Factor: It is easy to get a greater capacity factor for a Pitch Regulated WEG, since only a new pitch control strategy (Software) and a smaller generator at same speed is needed.

24 85 Reduced loading on the tower and foundation: The bending load on the tower and foundation from the rotor is relatively small as horizontal forces becomes smaller due to reduced drags across the blade profile at high wind speeds. Less Noise at large wind speed: At large wind speeds, the blade angle are greater and this in turn results in less noise from the blade tip. Blade as one Structural Element: Each blade is one structural element without hydraulic system and/or mechanical systems to rotate the blade tip as an aerodynamic brake. For PitchRegulated WEG s, the total blade is an aerodynamic brake. As such, even at low wind velocity, the Pitch regulated blade has a large surface area against the wind and as the windvelocity increases this surface area decreases gradually resulting in optimum production at all times. 4.7 SCOPE FOR THE FUTURE For adapting the usage of the pitch angle mechanism of the stepper motor as shown in Figure 4.17 in place of the hydraulic actuator, following mechanism is involved given below: 1. Stepper motor 10 Kg torque, 60 RPM, 24 V and 2 amps, 10 degree. 2. Single axis travel mechanism. 3. Piston inside the shaft. 4. Converter for linear movement to circular movement. Based on the RPM sense, the stepper motor will rotate clockwise or

25 86 anticlockwise of travel mechanism. The travel mechanism will move the piston to front and back (that is some linear movement). The linear movement of the piston gets converted to circular movement of the blade axis by reciprocating links and it is an easy mechanism. This converts linear moment to circular moment, there by making the blade rotate circularly. Figure 4.17 Pitch angle mechanism of the stepper motor The cost is very low comparing to hydraulic actuator mechanism. This mechanism can be used up to 30 KW wind turbine. 4.8 SUMMARY The pitch control system is easy to implement, but the response is slow and output power variation is large. The aerodynamic power control for the variable speed wind turbine can limit the power into the turbine by reducing the angle of the blades. The pitch control has a large response time.

26 87 Therefore, fast torque changes caused by wind gusts will affect the generator. The speed range of the generator is depending on the converter voltage and the load situation. A higher voltage available for the converter in the rotor circuit, will give a higher range of speed. A speed was chosen to make the generator choose the mechanical speed, which gives the best power output related to the wind speed. A rate limiter was chosen to avoid fast changes in the mechanical speed. The scaling of the converter could be investigated and compared with the winding ratio of the machine, to find the optimal winding ratio compared with bus voltage in the converter. The response time is mainly dictated by the hydraulic actuator, which limits the performance of the system. The controller should be used in conjunction with the pitch control system to avoid large losses during steady state operation. The pitch angle mechanism of the steeper motor is also discussed.

CHAPTER 5 ROTOR RESISTANCE CONTROL OF WIND TURBINE GENERATORS

CHAPTER 5 ROTOR RESISTANCE CONTROL OF WIND TURBINE GENERATORS 88 CHAPTER 5 ROTOR RESISTANCE CONTROL OF WIND TURBINE GENERATORS 5.1 INTRODUCTION The advances in power electronics technology have enabled the use of variable speed induction generators for wind energy

More information

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011 EE 742 Chap. 7: Wind Power Generation Y. Baghzouz Fall 2011 Overview Environmental pressures have led many countries to set ambitious goals of renewable energy generation. Wind energy is the dominant renewable

More information

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz EE 742 Chap. 7: Wind Power Generation Y. Baghzouz Wind Energy 101: See Video Link Below http://energy.gov/eere/videos/energy-101- wind-turbines-2014-update Wind Power Inland and Offshore Growth in Wind

More information

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION International Journal of Latest Research in Science and Technology Volume 3, Issue 1: Page No.68-74,January-February 2014 http://www.mnkjournals.com/ijlrst.htm ISSN (Online):2278-5299 POWER QUALITY IMPROVEMENT

More information

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM 47 CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM 4.1 INTRODUCTION Wind energy has been the subject of much recent research and development. The only negative

More information

Module 3: Types of Wind Energy Systems

Module 3: Types of Wind Energy Systems Module 3: Types of Wind Energy Systems Mohamed A. El-Sharkawi Department of Electrical Engineering University of Washington Seattle, WA 98195 http://smartenergylab.com Email: elsharkawi@ee.washington.edu

More information

Wind Turbine Emulation Experiment

Wind Turbine Emulation Experiment Wind Turbine Emulation Experiment Aim: Study of static and dynamic characteristics of wind turbine (WT) by emulating the wind turbine behavior by means of a separately-excited DC motor using LabVIEW and

More information

Simulation of Influence of Crosswind Gusts on a Four Wheeler using Matlab Simulink

Simulation of Influence of Crosswind Gusts on a Four Wheeler using Matlab Simulink Simulation of Influence of Crosswind Gusts on a Four Wheeler using Matlab Simulink Dr. V. Ganesh 1, K. Aswin Dhananjai 2, M. Raj Kumar 3 1, 2, 3 Department of Automobile Engineering 1, 2, 3 Sri Venkateswara

More information

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM 106 CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM 5.1 INTRODUCTION Inherent characteristics of renewable energy resources cause technical issues not encountered with conventional thermal,

More information

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM A THESIS Submitted in partial fulfilment of the requirements for the award of the degree of DOCTOR OF PHILOSOPHY

More information

CHAPTER 4 : RESISTANCE TO PROGRESS OF A VEHICLE - MEASUREMENT METHOD ON THE ROAD - SIMULATION ON A CHASSIS DYNAMOMETER

CHAPTER 4 : RESISTANCE TO PROGRESS OF A VEHICLE - MEASUREMENT METHOD ON THE ROAD - SIMULATION ON A CHASSIS DYNAMOMETER CHAPTER 4 : RESISTANCE TO PROGRESS OF A VEHICLE - MEASUREMENT METHOD ON THE ROAD - SIMULATION ON A CHASSIS DYNAMOMETER 1. Scope : This Chapter describes the methods to measure the resistance to the progress

More information

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM 61 CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM 3.1 INTRODUCTION The modeling of the real time system with STATCOM using MiPower simulation software is presented in this

More information

Statcom Operation for Wind Power Generator with Improved Transient Stability

Statcom Operation for Wind Power Generator with Improved Transient Stability Advance in Electronic and Electric Engineering. ISSN 2231-1297, Volume 4, Number 3 (2014), pp. 259-264 Research India Publications http://www.ripublication.com/aeee.htm Statcom Operation for Wind Power

More information

Session 5 Wind Turbine Scaling and Control W. E. Leithead

Session 5 Wind Turbine Scaling and Control W. E. Leithead SUPERGEN Wind Wind Energy Technology Session 5 Wind Turbine Scaling and Control W. E. Leithead Supergen 2 nd Training Seminar 24 th /25 th March 2011 Wind Turbine Scaling and Control Outline Introduction

More information

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators Abstract: G. Thrisandhya M.Tech Student, (Electrical Power systems), Electrical and Electronics Department,

More information

Workshop on Grid Integration of Variable Renewable Energy: Part 1

Workshop on Grid Integration of Variable Renewable Energy: Part 1 Workshop on Grid Integration of Variable Renewable Energy: Part 1 System Impact Studies March 13, 2018 Agenda Introduction Methodology Introduction to Generators 2 Introduction All new generators have

More information

Modeling, Simulation & Control of Induction Generators Used in Wind Energy Conversion

Modeling, Simulation & Control of Induction Generators Used in Wind Energy Conversion Chapter-3 Principles of Electrical Energy Conversion 3. 1 Introduction Several forms of energy can be converted into electrical energy basically by two methods known as direct or indirect conversion. In

More information

GOLDWIND 2.5MW PERMANENT MAGNET DIRECT-DRIVE (PMDD) WIND TURBINE

GOLDWIND 2.5MW PERMANENT MAGNET DIRECT-DRIVE (PMDD) WIND TURBINE Rotor Blade Rotor/Generator Bearing Cast Hub Auxiliary Crane Wind Measurement Equipment Pitch System Heat Exchanger Yaw System Base Frame PMDD Generator GOLDWIND 2.5MW PERMANENT MAGNET DIRECT-DRIVE (PMDD)

More information

Principles of Doubly-Fed Induction Generators (DFIG)

Principles of Doubly-Fed Induction Generators (DFIG) Renewable Energy Principles of Doubly-Fed Induction Generators (DFIG) Courseware Sample 86376-F0 A RENEWABLE ENERGY PRINCIPLES OF DOUBLY-FED INDUCTION GENERATORS (DFIG) Courseware Sample by the staff

More information

Application Notes. Calculating Mechanical Power Requirements. P rot = T x W

Application Notes. Calculating Mechanical Power Requirements. P rot = T x W Application Notes Motor Calculations Calculating Mechanical Power Requirements Torque - Speed Curves Numerical Calculation Sample Calculation Thermal Calculations Motor Data Sheet Analysis Search Site

More information

INTRODUCTION. I.1 - Historical review.

INTRODUCTION. I.1 - Historical review. INTRODUCTION. I.1 - Historical review. The history of electrical motors goes back as far as 1820, when Hans Christian Oersted discovered the magnetic effect of an electric current. One year later, Michael

More information

Modeling of doubly fed induction generator (DFIG) equipped wind turbine for dynamic studies

Modeling of doubly fed induction generator (DFIG) equipped wind turbine for dynamic studies Modeling of doubly fed induction generator (DFIG) equipped wind turbine for dynamic studies Mattia Marinelli, Andrea Morini, Andrea Pitto, Federico Silvestro Department of Electric Engineering, University

More information

Control of wind turbines and wind farms Norcowe 2015 PhD Summer school Single Turbine Control

Control of wind turbines and wind farms Norcowe 2015 PhD Summer school Single Turbine Control of wind and wind farms Norcowe 2015 PhD Summer school Single Turbine August, 2015 Department of Electronic Systems Aalborg University Denmark Outline Single Turbine Why is Historic Stall led in partial

More information

CHAPTER 1 INTRODUCTION

CHAPTER 1 INTRODUCTION CHAPTER 1 INTRODUCTION 1.1 CONSERVATION OF ENERGY Conservation of electrical energy is a vital area, which is being regarded as one of the global objectives. Along with economic scheduling in generation

More information

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL 3.1 Introduction Almost every mechanical movement that we see around us is accomplished by an electric motor. Electric machines are a means of converting

More information

Chapter 5. Design of Control Mechanism of Variable Suspension System. 5.1: Introduction: Objective of the Mechanism:

Chapter 5. Design of Control Mechanism of Variable Suspension System. 5.1: Introduction: Objective of the Mechanism: 123 Chapter 5 Design of Control Mechanism of Variable Suspension System 5.1: Introduction: Objective of the Mechanism: In this section, Design, control and working of the control mechanism for varying

More information

V MW Creating more from less

V MW Creating more from less V82-1.65 MW Creating more from less Grid compliance As wind turbines capture more of the electricity market each year, they have an increasingly significant role to play in grid management. Fortunately,

More information

EFFECT OF SURFACE ROUGHNESS ON PERFORMANCE OF WIND TURBINE

EFFECT OF SURFACE ROUGHNESS ON PERFORMANCE OF WIND TURBINE Chapter-5 EFFECT OF SURFACE ROUGHNESS ON PERFORMANCE OF WIND TURBINE 5.1 Introduction The development of modern airfoil, for their use in wind turbines was initiated in the year 1980. The requirements

More information

Inverter control of low speed Linear Induction Motors

Inverter control of low speed Linear Induction Motors Inverter control of low speed Linear Induction Motors Stephen Colyer, Jeff Proverbs, Alan Foster Force Engineering Ltd, Old Station Close, Shepshed, UK Tel: +44(0)1509 506 025 Fax: +44(0)1509 505 433 e-mail:

More information

Anupam *1, Prof. S.U Kulkarni 2 1 ABSTRACT I. INTRODUCTION II. MODELLING OF WIND SPEED

Anupam *1, Prof. S.U Kulkarni 2 1 ABSTRACT I. INTRODUCTION II. MODELLING OF WIND SPEED 2017 IJSRSET Volume 3 Issue 3 Print ISSN: 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology PMSG Based Wind Farm Analysis in ETAP Software Anupam *1, Prof. S.U Kulkarni 2 1 Department

More information

ECH 4224L Unit Operations Lab I Fluid Flow FLUID FLOW. Introduction. General Description

ECH 4224L Unit Operations Lab I Fluid Flow FLUID FLOW. Introduction. General Description FLUID FLOW Introduction Fluid flow is an important part of many processes, including transporting materials from one point to another, mixing of materials, and chemical reactions. In this experiment, you

More information

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM Ms. Dipali A. Umak 1, Ms. Trupti S. Thakare 2, Prof. R. K. Kirpane 3 1 Student (BE), Dept. of EE, DES s COET, Maharashtra,

More information

CHAPTER 5 ACTIVE AND REACTIVE POWER CONTROL OF DOUBLY FED INDUCTION GENERATOR WITH BACK TO BACK CONVERTER USING DIRECT POWER CONTROL

CHAPTER 5 ACTIVE AND REACTIVE POWER CONTROL OF DOUBLY FED INDUCTION GENERATOR WITH BACK TO BACK CONVERTER USING DIRECT POWER CONTROL 123 CHAPTER 5 ACTIVE AND REACTIVE POWER CONTROL OF DOUBLY FED INDUCTION GENERATOR WITH BACK TO BACK CONVERTER USING DIRECT POWER CONTROL 5.1 INTRODUCTION Wind energy generation has attracted much interest

More information

CHAPTER 6 INTRODUCTION TO MOTORS AND GENERATORS

CHAPTER 6 INTRODUCTION TO MOTORS AND GENERATORS CHAPTER 6 INTRODUCTION TO MOTORS AND GENERATORS Objective Describe the necessary conditions for motor and generator operation. Calculate the force on a conductor carrying current in the presence of the

More information

Job Sheet 2 Aerodynamics Power Control

Job Sheet 2 Aerodynamics Power Control Job Sheet 2 Aerodynamics Power Control Power Control Power control is an important feature of a wind turbine. It regulates the speed of rotation of the rotor assembly when wind is present. For stand-alone

More information

ABS. Prof. R.G. Longoria Spring v. 1. ME 379M/397 Vehicle System Dynamics and Control

ABS. Prof. R.G. Longoria Spring v. 1. ME 379M/397 Vehicle System Dynamics and Control ABS Prof. R.G. Longoria Spring 2002 v. 1 Anti-lock Braking Systems These systems monitor operating conditions and modify the applied braking torque by modulating the brake pressure. The systems try to

More information

CHAPTER 3 DESIGN OF THE LIMITED ANGLE BRUSHLESS TORQUE MOTOR

CHAPTER 3 DESIGN OF THE LIMITED ANGLE BRUSHLESS TORQUE MOTOR 33 CHAPTER 3 DESIGN OF THE LIMITED ANGLE BRUSHLESS TORQUE MOTOR 3.1 INTRODUCTION This chapter presents the design of frameless Limited Angle Brushless Torque motor. The armature is wound with toroidal

More information

CHAPTER 5 ANALYSIS OF COGGING TORQUE

CHAPTER 5 ANALYSIS OF COGGING TORQUE 95 CHAPTER 5 ANALYSIS OF COGGING TORQUE 5.1 INTRODUCTION In modern era of technology, permanent magnet AC and DC motors are widely used in many industrial applications. For such motors, it has been a challenge

More information

Reduction of Self Induced Vibration in Rotary Stirling Cycle Coolers

Reduction of Self Induced Vibration in Rotary Stirling Cycle Coolers Reduction of Self Induced Vibration in Rotary Stirling Cycle Coolers U. Bin-Nun FLIR Systems Inc. Boston, MA 01862 ABSTRACT Cryocooler self induced vibration is a major consideration in the design of IR

More information

Modelling of electronic throttle body for position control system development

Modelling of electronic throttle body for position control system development Chapter 4 Modelling of electronic throttle body for position control system development 4.1. INTRODUCTION Based on the driver and other system requirements, the estimated throttle opening angle has to

More information

Armature Reaction and Saturation Effect

Armature Reaction and Saturation Effect Exercise 3-1 Armature Reaction and Saturation Effect EXERCISE OBJECTIVE When you have completed this exercise, you will be able to demonstrate some of the effects of armature reaction and saturation in

More information

MOTOR VEHICLE HANDLING AND STABILITY PREDICTION

MOTOR VEHICLE HANDLING AND STABILITY PREDICTION MOTOR VEHICLE HANDLING AND STABILITY PREDICTION Stan A. Lukowski ACKNOWLEDGEMENT This report was prepared in fulfillment of the Scholarly Activity Improvement Fund for the 2007-2008 academic year funded

More information

Page 1. Design meeting 18/03/2008. By Mohamed KOUJILI

Page 1. Design meeting 18/03/2008. By Mohamed KOUJILI Page 1 Design meeting 18/03/2008 By Mohamed KOUJILI I. INTRODUCTION II. III. IV. CONSTRUCTION AND OPERATING PRINCIPLE 1. Stator 2. Rotor 3. Hall sensor 4. Theory of operation TORQUE/SPEED CHARACTERISTICS

More information

Asia Pacific Research Initiative for Sustainable Energy Systems 2011 (APRISES11)

Asia Pacific Research Initiative for Sustainable Energy Systems 2011 (APRISES11) Asia Pacific Research Initiative for Sustainable Energy Systems 2011 (APRISES11) Office of Naval Research Grant Award Number N0014-12-1-0496 Hydrogen Energy System Simulation Model for Grid Management

More information

Lab 6: Wind Turbine Generators

Lab 6: Wind Turbine Generators Lab 6: Wind Turbine Generators Name: Pre Lab Tip speed ratio: Tip speed ratio (TSR) is defined as: Ω, where Ω=angular velocity of wind, and R=radius of rotor (blade length). If the rotational speed of

More information

Chapter 7: DC Motors and Transmissions. 7.1: Basic Definitions and Concepts

Chapter 7: DC Motors and Transmissions. 7.1: Basic Definitions and Concepts Chapter 7: DC Motors and Transmissions Electric motors are one of the most common types of actuators found in robotics. Using them effectively will allow your robot to take action based on the direction

More information

Low Speed Wind Turbines. Current Applications and Technology Development

Low Speed Wind Turbines. Current Applications and Technology Development Low Speed Wind Turbines Current Applications and Technology Development Why low wind speed turbines? Easily accessible prime class 6 sites are disappearing. Many class 6 sites are located in remote areas

More information

Integration of Large Wind Farms into Electric Grids

Integration of Large Wind Farms into Electric Grids Integration of Large Wind Farms into Electric Grids Dr Mohammad AlZoubi Introduction Development WHAT IS NEXT!! Over the next 12 years, Europe must build new power capacity equal to half the current total.

More information

Wind Generation and its Grid Conection

Wind Generation and its Grid Conection Wind Generation and its Grid Conection J.B. Ekanayake PhD, FIET, SMIEEE Department of Electrical and Electronic Eng., University of Peradeniya Content Wind turbine basics Wind generators Why variable speed?

More information

ME 466 PERFORMANCE OF ROAD VEHICLES 2016 Spring Homework 3 Assigned on Due date:

ME 466 PERFORMANCE OF ROAD VEHICLES 2016 Spring Homework 3 Assigned on Due date: PROBLEM 1 For the vehicle with the attached specifications and road test results a) Draw the tractive effort [N] versus velocity [kph] for each gear on the same plot. b) Draw the variation of total resistance

More information

Maxwell Technologies GmbH Brucker Strasse 21 D Gilching Germany Phone: +49 (0) Fax: +49 (0)

Maxwell Technologies GmbH Brucker Strasse 21 D Gilching Germany Phone: +49 (0) Fax: +49 (0) WHITE PAPER ULTRACAPACITORS IMPROVE RELIABILITY FOR WIND TURBINE PITCH SYSTEMS Adrian Schneuwly Introduction Today s advanced wind turbines are three-bladed, variable speed turbines. The rotor blades are

More information

MAJOR SYSTEM FUNCTIONS

MAJOR SYSTEM FUNCTIONS MAJOR SYSTEM FUNCTIONS The ROTOR converts the aerodynamic energy in the wind to mechanical shaft torque. It also provides a lightning path from the blade tips to the main shaft. The GENERATOR converts

More information

LECTURE 19 WIND POWER SYSTEMS. ECE 371 Sustainable Energy Systems

LECTURE 19 WIND POWER SYSTEMS. ECE 371 Sustainable Energy Systems LECTURE 19 WIND POWER SYSTEMS ECE 371 Sustainable Energy Systems 1 GENERATORS Blades convert the wind kinetic energy to a shaft power to spin a generator and produce electricity A generator has two parts

More information

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR 100 CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR 6.1 INTRODUCTION Conventional energy resources are not sufficient to meet the increasing electrical power demand. The usages of

More information

Technical Explanation for Inverters

Technical Explanation for Inverters CSM_Inverter_TG_E_1_2 Introduction What Is an Inverter? An inverter controls the frequency of power supplied to an AC motor to control the rotation speed of the motor. Without an inverter, the AC motor

More information

Introduction to hmtechnology

Introduction to hmtechnology Introduction to hmtechnology Today's motion applications are requiring more precise control of both speed and position. The requirement for more complex move profiles is leading to a change from pneumatic

More information

Control Scheme for Grid Connected WECS Using SEIG

Control Scheme for Grid Connected WECS Using SEIG Control Scheme for Grid Connected WECS Using SEIG B. Anjinamma, M. Ramasekhar Reddy, M. Vijaya Kumar, Abstract: Now-a-days wind energy is one of the pivotal options for electricity generation among all

More information

Frequency Control of Isolated Network with Wind and Diesel Generators by Using Frequency Regulator

Frequency Control of Isolated Network with Wind and Diesel Generators by Using Frequency Regulator Frequency Control of Isolated Network with Wind and Diesel Generators by Using Frequency Regulator Dr.Meenakshi mataray,ap Department of Electrical Engineering Inderprastha Engineering college (IPEC) Abstract

More information

Doubly fed electric machine

Doubly fed electric machine Doubly fed electric machine Doubly fed electric machines are electric motors or electric generators that have windings on both stationary and rotating parts, where both windings transfer significant power

More information

Improvement of Vehicle Dynamics by Right-and-Left Torque Vectoring System in Various Drivetrains x

Improvement of Vehicle Dynamics by Right-and-Left Torque Vectoring System in Various Drivetrains x Improvement of Vehicle Dynamics by Right-and-Left Torque Vectoring System in Various Drivetrains x Kaoru SAWASE* Yuichi USHIRODA* Abstract This paper describes the verification by calculation of vehicle

More information

INTRODUCTION Principle

INTRODUCTION Principle DC Generators INTRODUCTION A generator is a machine that converts mechanical energy into electrical energy by using the principle of magnetic induction. Principle Whenever a conductor is moved within a

More information

DESIGN AND ANALYSIS OF UNDERTRAY DIFFUSER FOR A FORMULA STYLE RACECAR

DESIGN AND ANALYSIS OF UNDERTRAY DIFFUSER FOR A FORMULA STYLE RACECAR DESIGN AND ANALYSIS OF UNDERTRAY DIFFUSER FOR A FORMULA STYLE RACECAR Ali Asgar S. Khokhar 1, Suhas S. Shirolkar 2 1 Graduate in Mechanical Engineering, KJ Somaiya College of Engineering, Mumbai, India.

More information

Figure1: Kone EcoDisc electric elevator drive [2]

Figure1: Kone EcoDisc electric elevator drive [2] Implementation of an Elevator s Position-Controlled Electric Drive 1 Ihedioha Ahmed C. and 2 Anyanwu A.M 1 Enugu State University of Science and Technology Enugu, Nigeria 2 Transmission Company of Nigeria

More information

Technical specifications. Wind Turbine GS 21 S. Power 60 kwp

Technical specifications. Wind Turbine GS 21 S. Power 60 kwp Technical specifications Wind Turbine GS 21 S Power 60 kwp GS 21 S - 60 kwp The best wind turbines, without compromise. In order to exploit the kinetic energy contained in the wind and convert it into

More information

Application Information

Application Information Moog Components Group manufactures a comprehensive line of brush-type and brushless motors, as well as brushless controllers. The purpose of this document is to provide a guide for the selection and application

More information

V MW The future for low wind sites

V MW The future for low wind sites V0-2.75 MW The future for low wind sites Knowing which way the wind blows The V0-2.75 MW turbine know which way the wind blows, and is designed to follow it. A significant advance in wind turbine efficiency,

More information

Technology Requirements for Cold and Tropical Wind-Diesel Applications. Chris McKay Product Manager Northwind 100 Ottawa 2009

Technology Requirements for Cold and Tropical Wind-Diesel Applications. Chris McKay Product Manager Northwind 100 Ottawa 2009 Technology Requirements for Cold and Tropical Wind-Diesel Applications Chris McKay Product Manager Northwind 100 Ottawa 2009 Wind-Diesel Technology Needs Low maintenance High reliability Diesel grid friendly

More information

Unit-II Synchronous Motor

Unit-II Synchronous Motor Unit-II Synchronous Motor CONSTRUCTION OF THREE PHASE SYNCHRONOUS MOTOR PRINCIPLE OF OPERATION Prepared By P.Priyadharshini Ap/EEE - 1 - Note: 1. The average torque exerted on the rotor of synchronous

More information

Transmitted by the expert from the European Commission (EC) Informal Document No. GRRF (62nd GRRF, September 2007, agenda item 3(i))

Transmitted by the expert from the European Commission (EC) Informal Document No. GRRF (62nd GRRF, September 2007, agenda item 3(i)) Transmitted by the expert from the European Commission (EC) Informal Document No. GRRF-62-31 (62nd GRRF, 25-28 September 2007, agenda item 3(i)) Introduction of Brake Assist Systems to Regulation No. 13-H

More information

Job Sheet 6 Pitch Control

Job Sheet 6 Pitch Control Job Sheet 6 Pitch Control Not all wind can be captured as energy by the wind turbine. Some wind has to pass by the blades for the rotor system to function properly. There are limits to how fast motors

More information

On Control Strategies for Wind Turbine Systems

On Control Strategies for Wind Turbine Systems On Control Strategies for Wind Turbine Systems Niall McMahon December 21, 2011 More notes to follow at: http://www.niallmcmahon.com/msc_res_notes.html 1 Calculations for Peak Tip Speed Ratio Assuming that

More information

Power Control of a PMSG based Wind Turbine System Above Rated Wind Speed

Power Control of a PMSG based Wind Turbine System Above Rated Wind Speed International Renewable Energy Congress November 5-7, 010 Sousse, Tunisia Power Control of a PMSG based Wind Turbine System Above Rated Wind Speed M. Kesraoui 1, O. Bencherouda and Z. Mesbahi 1 Laboratory

More information

Simple Gears and Transmission

Simple Gears and Transmission Simple Gears and Transmission Simple Gears and Transmission page: of 4 How can transmissions be designed so that they provide the force, speed and direction required and how efficient will the design be?

More information

Linear Shaft Motors in Parallel Applications

Linear Shaft Motors in Parallel Applications Linear Shaft Motors in Parallel Applications Nippon Pulse s Linear Shaft Motor (LSM) has been successfully used in parallel motor applications. Parallel applications are ones in which there are two or

More information

Squirrel cage induction generator based wind farm connected with a single power converter to a HVDC grid. Lluís Trilla PhD student

Squirrel cage induction generator based wind farm connected with a single power converter to a HVDC grid. Lluís Trilla PhD student Squirrel cage induction generator based wind farm connected with a single power converter to a HVDC grid Lluís Trilla PhD student Current topology of wind farm Turbines are controlled individually Wind

More information

DeepWind-from idea to 5 MW concept

DeepWind-from idea to 5 MW concept DeepWind 2014-11 th Deep Sea Offshore Wind R&D Conference 22-24 January 2014 Trondheim, No Uwe Schmidt Paulsen a uwpa@dtu.dk b Helge Aa. Madsen, Per H. Nielsen,Knud A. Kragh c Ismet Baran,Jesper H. Hattel

More information

Performance of DC Motor Supplied From Single Phase AC-DC Rectifier

Performance of DC Motor Supplied From Single Phase AC-DC Rectifier Performance of DC Motor Supplied From Single Phase AC-DC Rectifier Dr Othman A. Alnatheer Energy Research Institute-ENRI King Abdulaziz City for Science and Technology- KACST P O Box 6086, Riyadh 11442,

More information

Figure 1: Forces Are Equal When Both Their Magnitudes and Directions Are the Same

Figure 1: Forces Are Equal When Both Their Magnitudes and Directions Are the Same Moving and Maneuvering 1 Cornerstone Electronics Technology and Robotics III (Notes primarily from Underwater Robotics Science Design and Fabrication, an excellent book for the design, fabrication, and

More information

EE 370L Controls Laboratory. Laboratory Exercise #E1 Motor Control

EE 370L Controls Laboratory. Laboratory Exercise #E1 Motor Control 1. Learning Objectives EE 370L Controls Laboratory Laboratory Exercise #E1 Motor Control Department of Electrical and Computer Engineering University of Nevada, at Las Vegas To demonstrate the concept

More information

Electric Networks/Ina Lehto Updated Original 12/2011

Electric Networks/Ina Lehto Updated Original 12/2011 1 TECHNICAL APPENDIX 2 TO THE GUIDELINES CONNECTING AN ELECTRICITY GENERATION INSTALLATION TO THE DISTRIBUTION NETWORK CONNECTING AN INSTALLATION WITH A NOMINAL RATED CAPACITY OF OVER 100 These instructions

More information

This chapter gives details of the design, development, and characterization of the

This chapter gives details of the design, development, and characterization of the CHAPTER 5 Electromagnet and its Power Supply This chapter gives details of the design, development, and characterization of the electromagnets used to produce desired magnetic field to confine the plasma,

More information

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR Velimir Nedic Thomas A. Lipo Wisconsin Power Electronic Research Center University of Wisconsin Madison

More information

CHAPTER 6 POWER QUALITY IMPROVEMENT OF SCIG IN WIND FARM USING STATCOM WITH SUPERCAPACITOR

CHAPTER 6 POWER QUALITY IMPROVEMENT OF SCIG IN WIND FARM USING STATCOM WITH SUPERCAPACITOR 120 CHAPTER 6 POWER QUALITY IMPROVEMENT OF SCIG IN WIND FARM USING STATCOM WITH SUPERCAPACITOR 6.1 INTRODUCTION For a long time, SCIG has been the most used generator type for wind turbines because of

More information

Brochure. Wind turbine generators Reliable technology for all turbine applications

Brochure. Wind turbine generators Reliable technology for all turbine applications Brochure Wind turbine generators Reliable technology for all turbine applications 2 ABB Wind turbine generators We provide motors and generators, services and expertise to save energy and improve customers

More information

Product Manual. 42BYGH40(M)-160-4A NEMA 17 Bipolar 5.18:1. Planetary Gearbox Stepper

Product Manual. 42BYGH40(M)-160-4A NEMA 17 Bipolar 5.18:1. Planetary Gearbox Stepper Product Manual 42BYGH40(M)-160-4A NEMA 17 Bipolar 5.18:1 Planetary Gearbox Stepper Phidgets - Product Manual 42BYGH40(M)-160-4A NEMA 17 Bipolar 5.18:1 Planetary Gearbox Stepper Phidgets Inc. 2011 Contents

More information

SOME FACTORS THAT INFLUENCE THE PERFORMANCE OF

SOME FACTORS THAT INFLUENCE THE PERFORMANCE OF SOME FACTORS THAT INFLUENCE THE PERFORMANCE OF Authored By: Robert Pulford Jr. and Engineering Team Members Haydon Kerk Motion Solutions There are various parameters to consider when selecting a Rotary

More information

Pumped storage for balancing wind power fluctuations in an isolated grid

Pumped storage for balancing wind power fluctuations in an isolated grid Wind Power to the Grid EPE Wind Energy Chapter 1 st seminar Delft University of Technology, 8-9 March 008 Pumped storage for balancing wind power fluctuations in an isolated grid Jon Are Suul, Professor

More information

Possibilities of Distributed Generation Simulations Using by MATLAB

Possibilities of Distributed Generation Simulations Using by MATLAB Possibilities of Distributed Generation Simulations Using by MATLAB Martin Kanálik, František Lizák ABSTRACT Distributed sources such as wind generators are becoming very imported part of power system

More information

Implementation of FC-TCR for Reactive Power Control

Implementation of FC-TCR for Reactive Power Control IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, Volume 5, Issue 5 (May. - Jun. 2013), PP 01-05 Implementation of FC-TCR for Reactive Power Control

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 3-3 Venturi Tubes EXERCISE OBJECTIVE In this exercise, you will study the relationship between the flow rate and the pressure drop produced by a venturi tube. You will describe the behavior of

More information

V MW & 2.0 MW Built on experience

V MW & 2.0 MW Built on experience V90-1.8 MW & 2.0 MW Built on experience Innovations in blade technology Optimal efficiency The OptiSpeed * generators in the V90-1.8 MW and the V90-2.0 MW have been adapted from those in Vestas highly

More information

ned100 Wind Turbine Generator a step towards your energy independence

ned100 Wind Turbine Generator a step towards your energy independence ned100 Wind Turbine Generator a step towards your energy independence Energy production 450 Ø22 Ø24 4.5 138 155 5.0 183 203 5.5 230 252 6.0 276 300 6.5 321 346 7.0 363 388 7.5 401 425 8.0 435 ---- 8.5

More information

Principles of Electrical Engineering

Principles of Electrical Engineering D.C GENERATORS Principle of operation of D.C machines, types of D.C Generators, e.m.f equation of D.C Generator, O.C.C of a D.C Shunt Generator, Load characteristics of D.C.Generators GENERATOR PRINCIPLE:

More information

ECEN 667 Power System Stability Lecture 19: Load Models

ECEN 667 Power System Stability Lecture 19: Load Models ECEN 667 Power System Stability Lecture 19: Load Models Prof. Tom Overbye Dept. of Electrical and Computer Engineering Texas A&M University, overbye@tamu.edu 1 Announcements Read Chapter 7 Homework 6 is

More information

A Comparative Study of Constant Speed and Variable Speed Wind Energy Conversion Systems

A Comparative Study of Constant Speed and Variable Speed Wind Energy Conversion Systems GRD Journals- Global Research and Development Journal for Engineering Volume 1 Issue 10 September 2016 ISSN: 2455-5703 A Comparative Study of Constant Speed and Variable Speed Wind Energy Conversion Systems

More information

FLUID FLOW. Introduction

FLUID FLOW. Introduction FLUID FLOW Introduction Fluid flow is an important part of many processes, including transporting materials from one point to another, mixing of materials, and chemical reactions. In this experiment, you

More information

CONTRIBUTION TO THE CINEMATIC AND DYNAMIC STUDIES OF HYDRAULIC RADIAL PISTON MOTORS.

CONTRIBUTION TO THE CINEMATIC AND DYNAMIC STUDIES OF HYDRAULIC RADIAL PISTON MOTORS. Ing. MIRCEA-TRAIAN CHIMA CONTRIBUTION TO THE CINEMATIC AND DYNAMIC STUDIES OF HYDRAULIC RADIAL PISTON MOTORS. PhD Thesis Abstract Advisor, Prof. dr. ing. matem. Nicolae URSU-FISCHER D.H.C. Cluj-Napoca

More information

Rotor imbalance cancellation

Rotor imbalance cancellation White paper Rotor imbalance cancellation Imbalance in a wind turbine rotor is a typical problem of both new and older wind turbines. This paper describes an approach for minimizing rotor imbalance using

More information

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian Shunt Capacitor Bank Protection in UHV Pilot Project Qing Tian 2012-5 INTRODUCTION State Grid Corp. of China, the largest electric power provider in the country, has first build a 1000 kv transmission

More information

Fuzzy based Adaptive Control of Antilock Braking System

Fuzzy based Adaptive Control of Antilock Braking System Fuzzy based Adaptive Control of Antilock Braking System Ujwal. P Krishna. S M.Tech Mechatronics, Asst. Professor, Mechatronics VIT University, Vellore, India VIT university, Vellore, India Abstract-ABS

More information