PRICE LIST 08/2008. GROSS prices in L19. Validity: August 1 December 31, 2008
|
|
- Georgina Johns
- 6 years ago
- Views:
Transcription
1 PRICE LIST 08/2008 GROSS prices in Validity: August 1 December 31, 2008 L19
2 How to use this price list The price list is divided in the following chapters: Extraction arms and hoses Stationary units Portable and mobile units Fans Central filter systems Fixing material, accessories for ducting and options Electric components and accessories Replacement filters Multiple arm systems General filtration Each chapter fully describes the main products with an image of the product in question. Underneath each product you can choose the articles to configure a complete extraction system. Attention: The articles stated in one box belong to each other, so they should not be separated. Details about the products to complete a system can be found on the page number indicated at the right side of the column. To facilitate selection of the right configuration, you can consult the following tables in the back of the price list: Selection diagrams Filter selection Selection wall bracket Selection single fan Selection central fan Selection multiple arm system with Statiflex 6000-MS Selection airflow Statiflex 6000-MS Selection SF LI/RI Indication duct diameter Product overview Overview fan control
3 PRICE LIST 08/2008 Table of contents Price list (L19). Subject to modifications. Gross prices, excl. VAT, ex works Alkmaar/Holland, excl. waste disposal fee. N/E *) Page Extraction arms and hoses LTA 2.0 Telescopic arm E 3 LFA 2.0 Flexible extraction arm E 3 LFA 3.0/4.0 Flexible extraction arm E 4 LFA 3.1/4.1 Ultraflexible extraction arm E 4 LFA 4.1-LC Ultraflexible extraction arm for low ceiling E 4 EC 2 Extension crane E 5 SUS 5/160 Extraction hose E 5 SUS 5/203 Extraction hose E 5 Stationary units Statiflex 200-M Stationary unit with disposable filter E 6 Statiflex 400-MS Stationary unit with self-cleaning filter E 6 Statiflex 300-1E Stationary unit with electrostatic filter N 6 Statiflex 300-1M Stationary unit with disposable bag filter N 7 Portable and mobile units Miniflex Portable welding fume extractor E 8 Mobiflex 100-NF Portable fan E 8 Mobiflex 200-M Mobile welding fume extractor with disposable filter E 9 Mobiflex 400-MS Mobile welding fume extractor with self-cleaning filter E 9 Mobiflex 300-E Mobile welding fume extractor with electrostatic filter E 10 Fans SF 1400 Extraction fan E 11 SF 2400 Extraction fan E 11 SF 4200 Extraction fan E 12 SF 5500 Central extraction fan N 12 SF 8000 Central extraction fan N 12 SF Central extraction fan N 13 SF Central extraction fan N 13 Central filter systems Statiflex 6000-MS Central system with self-cleaning filter N 14 Statiflex 300-2E Stationary unit with electrostatic filter N 15 Statiflex 300-3E Stationary unit with electrostatic filter N 15 Statiflex 300-2M Stationary unit with disposable bag filter N 16 Statiflex 300-3M Stationary unit with disposable bag filter N 16 Fixing material, accessories for ducting and options Mounting material 17 Connection material 17 Air inlet Statiflex 6000-MS 18 Valves and dampers 18 Silencers 19 Nozzles and hoses Miniflex 19 Grids 20 Oil drainer 20 1
4 PRICE LIST 08/2008 Table of contents Price list (L19). Subject to modifications. Gross prices, excl. VAT, ex works Alkmaar/Holland, excl. waste disposal fee. N/E *) Page Electric components and accessories Working light + automatic start/stop 21 Control boxes 21 Motor protection switches 22 Thermal relays 22 Transformer/relay kit 22 Cable kits 23 Power supply 23 Motor starters 23 Pulley sets 23 Replacement filters Pre filters 24 Main filter 24 Final filters 25 Multiple arm systems Concept 1 Fully Controlled Multiple Fan System E 27 Concept 2 Uncontrolled One Fan System E 29 Concept 3 Semi-controlled One Fan System E 30 Concept 4 Fully Controlled One Fan System E 31 General filtration LDS Lincoln Diluter System N 33 P-P Push-pull system N 34 H25-EF Industrial air cleaner with electrostatic filter N 35 H50-EF Industrial air cleaner with electrostatic filter N 35 Selection diagrams Filter selection 36 Selection wall bracket 36 Selection single fan 37 Selection central fan 37 Selection multiple arm system with Statiflex 6000-MS 38 Selection airflow Statiflex 6000-MS 38 Selection SF LI/RI 38 Indication duct diameter 38 Product overview 39 Overview fan control 40 2
5 Extraction arms and hoses LTA 2.0 Telescopic arm LTA 2.0 1,1-2,4 m ,00 Telescopic arm Ø 203 mm with RotaHood, throttle valve and DeBlock balance system. Including mounting bracket. LFA 2.0 Flexible extraction arm LFA m ,00 Flexible arm Ø 203 mm with RotaHood, throttle valve and DeBlock balance system. Incl. connection flange NCF. Extraction fans SF 1400 Fan 1400 m3/h free-blowing; 1400 rpm, 0,55 kw 400V/3ph/50Hz ,00 11 SF 2400 Fan 2400 m3/h free-blowing; 2800 rpm, 0,75 kw 400V/3ph/50Hz ,00 11 Wall bracket TMB For mounting SF 1400/ ,00 17 Options MPS Motor protection switch (400V/3ph/50Hz) SF 1400: ,00 22 SF 2400: ,00 22 WL Working light ,00 21 NCW 11 Connection wire 11 m ,00 22 CB Control box ,00 21 NTR Thermal relay (400V/3ph/50Hz) SF 1400: ,00 22 SF 2400: ,00 22 WL+AST Working light + automatic start/stop ,00 21 NCW 11 Connection wire 11 m ,00 22 CB Control box ,00 21 NTR Thermal relay (400V/3ph/50Hz) SF 1400: ,00 22 SF 2400: ,00 22 WCS Welding cable sensor ,00 21 CB-WCS Control box ,00 21 NTR Thermal relay (400V/3ph/50Hz) SF 1400: ,00 22 SF 2400: ,00 22 Miscellaneous CKS Connection kit ,00 17 NRV Non-return valve Ø 160 mm ,
6 LFA 3.0/4.0 Flexible extraction arm LFA m ,00 LFA m ,00 Flexible arm Ø 203 mm with RotaHood, throttle valve and DeBlock balance system. LFA 3.1/4.1 Ultraflexible extraction arm LFA m ,00 LFA m ,00 Flexible arm Ø 203 mm with RotaHood, throttle valve and Balance balance system. LFA 4.1-LC Ultraflexible extraction arm for low ceiling LFA 4.1-LowCeiling 4 m ,00 Flexible arm Ø 203 mm with RotaHood, throttle valve and Balance balance system. Particularly suitable for mounting under a low ceiling (min. 2,5 m). Extension crane (option) EC 2 Extension crane (for LFA 3.0/4.0/3.1/4.1 only) 2 m ,00 5 EC 2 Extension crane (for LFA 3.0/4.0/3.1/4.1 only) 2 m ,00 5 EXT EC 4 Extension set to EC m ,00 5 Extraction fans SF 2400 Fan 2400 m3/h free-blowing; 2800 rpm, 0,75 kw. 400V/3ph/50Hz ,00 11 SF 4200 Fan 3000 m3/h free-blowing; 2800 rpm, 1,5 kw. 400V/3ph/50Hz ,00 11 Wall bracket TMB For mounting LFA 3.0/4.0/3.1/4.1 + EC 2 + SF ,00 17 For mounting LFA 4.1-LC + SF 2400 LMB For mounting LFA 3.0/4.0/3.1/4.1 + SF 2400/ ,00 17 Options MPS Motor protection switch (400V/3ph/50Hz) SF 2400: ,00 22 SF 4200: ,00 22 WL Working light ,00 21 NCW 11 Connection wire 11 m ,00 22 CB Control box ,00 21 NTR Thermal relay (400V/3ph/50Hz) SF 2400: ,00 22 SF 4200: ,
7 WL+AST Working light + automatic start/stop ,00 21 NCW 11 Connection wire 11 m ,00 22 CB Control box ,00 21 NTR Thermal relay (400V/3ph/50Hz) SF 2400: ,00 22 SF 4200: ,00 22 WCS Welding cable sensor ,00 21 CB-WCS Control box ,00 21 NTR Thermal relay (400V/3ph/50Hz) SF 2400: ,00 22 SF 4200: ,00 22 Miscellaneous NRV Non-return valve ,00 18 EC 2 Extension crane EC 2 2 m ,00 Extension crane Ø 203 mm with HandyStop. To be used in combination with LFA 3.0/4.0 and LFA 3.1/4.1. Options EXT EC 4 Extension set EC m ,00 RS 2 Rail set 1,5 m ,00 17 SUS 5/160 Extraction hose SUS 5/160 5 m ,00 Extraction hose for portable fan Mobiflex 100-NF. Options EXS 5/160 Exhaust/extension hose 5 m ,00 SUS 5/203 Extraction hose SUS 5/203 5 m ,00 Extraction hose for mobile unit Mobiflex 200-M/300- E/400-MS. Options EXS 5/203 Exhaust/extension hose 5 m ,00 5
8 Stationary units STATIFLEX 200-M Stationary unit with disposable filter Statiflex 200-M ,00 Stationary welding fume filter with disposable LongLife filter cartridge. Filter surface area 50 m2 with ExtraCoat treatment. Including filter pollution indicator. No voltage required. Replacement filters Pre filter Aluminium spark arrester ,00 24 FCC 50 Filter cartridge 50 m ,00 24 Miscellaneous NRV-HD Non-return valve ,00 18 STATIFLEX 400-MS Stationary unit with self-cleaning filter Statiflex 400-MS ,00 Stationary welding fume filter with fully automatic selfcleaning mechanical RotaPulse filter with ExtraCoat treatment. Filter surface area 30 m2. Connection for 4-5 bar of dry, oil-free compressed air. To be connected to a control box CB. Replacement filters Pre filter Aluminium spark arrester ,00 24 FCC 30 Filter cartridge 30 m ,00 24 STATIFLEX 300-1E Stationary unit with electrostatic filter Pre filters Industrial air cleaner with electrostatic filter. To be installed in ductwork or to be connected to extraction arm(s) with fan. Including oil collector. Possibility to install an oil drainer. Filters included: FIS and FCS; pre and final filters to be ordered separately. No fan included. Max. filter capacity: 2500 m3/h. Filter surface area: 14,2 m2. The Statiflex 300-1E unit can be used for the extraction of oilmist, provided the suitable prefilter (SOD) and an oil drainer have been installed. *) Incl. 24V circuit. 230V/1ph/50Hz*) ,00 400V/3ph/50Hz*) ,00 Airflow right-left: 230V/1ph/50Hz*) ,00 400V/3ph/50Hz*) ,00 SAF Aluminium pre/final filter ,00 24 SOD Demister for oilmist application ,00 24 Final filters Airflow left-right: SAF Aluminium pre/final filter ,00 25 SSF Progressive synthetic filter; filter class G ,00 25 SCF Activated carbon filter; type RB ,00 26 SBF Synthetic bag filter; filter class F ,
9 Connection pieces RP Connection piece SF 2400 to RP ,00 18 Adapter 315 Adapter RP and RP ,00 18 RP Connecting piece Statiflex 300-1E to ducting Ø 315 mm ,00 18 Options Oil drainer Oil drainer ,00 20 OG 25 Outlet grid ,00 20 SFM 25 Stationary unit with bag filter as final filter 938,00 7 Replacement filters SAF Aluminium pre/final filter ,00 24 SOD Demister for oilmist application ,00 24 FIS Ionisation section electrostatic main filter ,00 25 FCS Collector section electrostatic main filter ,00 25 SSF Progressive synthetic filter; filter class G ,00 25 SSF refill Refill SSF (filter without frame) ,00 25 SCF Activated carbon filter; type RB ,00 26 SBF Synthetic bag filter; filter class F ,00 26 STATIFLEX 300-1M Stationary unit with disposable bag filter Stationary unit with mechanical bag filter. For light industrial welding applications like TIG welding. Can also be mounted after an Statiflex 300-1E unit as a guard filter. To be installed in ductwork or to be connected to extraction arm(s) with fan. Filters included: SAF and SBF. Max. filter capacity: 2500 m3/h. No fan included. Airflow left-right: Airflow right-left: , ,00 Replacement filters SAF Aluminium pre/final filter ,00 24 SBF Synthetic bag filter; filter class F ,
10 Portable and mobile units MINIFLEX Portable welding fume extractor Miniflex (215) 230V/1ph/50Hz ,00 Miniflex UK (115) 115V/1ph/50Hz ,00 Portable high vacuum welding fume extractor, standard provided with: LongLife-H filter, filter surface 12 m2 HEPA filter aluminium pre filter automatic start/stop set of wheels extraction hose 2,5 m 2 sets carbon brushes. Capacity: 2 x 1000 W Special version Miniflex-I (BIA-W3) Miniflex with filter pollution indicator and sound signal 230V/1~/50Hz ,00 Options FAC HV Activated carbon filter , ,00 26 MBH Wall bracket ,00 17 HCH 45 Hose connection ,00 17 NKT Nozzle kit ,00 19 NKC Nozzle kit ,00 20 EN 20 Funnel nozzle ,00 20 EN 40 Slit extraction nozzle ,00 20 H2.5/45 Extraction/exhaust hose 2,5 m ,00 20 H5.0/45 Extraction/exhaust hose 5 m ,00 20 CP 45 Connection piece Ø 45 mm ,25 18 Replacement filters Pre filter Filter class G ,00 24 LongLife-H filter Disposable cartridge filter 12 m ,00 25 HEPA filter Filter class H ,00 26 MOBIFLEX 100-NF Portable fan Mobiflex 100-NF (115) 115V/1ph/50Hz ,00 Mobiflex 100-NF (215) 230V/1ph/50Hz ,00 Mobiflex 100-NF (235) 230V/3ph/50Hz ,00 Mobiflex 100-NF (435) 400V/3ph/50Hz ,00 Portable extraction fan with a free-blowing capacity of 2400 m3/h. Including 6 m cable and motor protection switch. To be connected to max. 20 m hose set. Extraction hose SUS 5/160 Flexible extraction hose with nozzle 5 m ,00 5 Extraction hose (option) EXS 5/203 Exhaust/extension hose 5 m ,00 8
11 MOBIFLEX 200-M Mobile welding fume extractor with disposable filter Mobiflex 200-M (115) 115V/1ph/50Hz ,00 Mobiflex 200-M (215) 230V/1ph/50Hz ,00 Mobiflex 200-M (235) 230V/3ph/50Hz ,00 Mobiflex 200-M (435) 400V/3ph/50Hz ,00 Mobile welding fume extractor with disposable LongLife filter cartridge. Filter surface area 50 m2. Fan 0,75 kw. Net extraction capacity 1250 m3/h. Including motor protection switch, filter pollution indicator and 5 m cable. Special version Mobiflex 200-M/BIA (435) Mobiflex 200-M with BIA-W3 certificate 400V/3~/50Hz ,00 Extraction arm/hose LFA 3.0 Flexible extraction arm 3 m ,00 4 LFA 4.0 Flexible extraction arm 4 m ,00 4 LFA 3.1 Ultraflexible extraction arm 3 m ,00 4 LFA 4.1 Ultraflexible extraction arm 4 m ,00 4 SUS 5/203 Extraction hose 5 m ,00 5 Extension hose (option; for SUS 5/203 only) EXS 5/203 Exhaust/extension hose 5 m ,00 Options and accessories (for LFA 3.0/4.0/3.1/4.1 only) WL Working light ,00 21 NCW 4 Connection wire 4 m ,00 23 TRK-200-M Transformer/relay kit (not for Mobiflex 200-M/BIA) ,00 23 WL+AST Working light + automatic start/stop ,00 21 NCW 4 Connection wire 4 m ,00 23 TRK-200-M Transformer/relay kit (not for Mobiflex 200-M/BIA) ,00 23 Activated carbon filter (option) FAC 50 Activated carbon filter 1,2 m ,00 25 Replacement filters Pre filter Aluminium spark arrester ,00 24 FCC 50 Filter cartridge 50 m ,00 24 FAC 50 Activated carbon filter ,00 25 MOBIFLEX 400-MS Mobile welding fume extractor with self-cleaning filter Mobiflex 400-MS (115) Mobiflex 400-MS (215) 230V/1ph/50Hz ,00 Mobiflex 400-MS (235) 230V/3ph/50Hz ,00 Mobiflex 400-MS (435) 400V/3ph/50Hz ,00 Mobile welding fume extractor with fully automatic selfcleaning mechanical RotaPulse filter with ExtraCoat treatment. Filter surface area 30 m2. Fan 0,75 kw. Net extraction capacity 1250 m3/h. Connection for 4-5 bar of dry, oil-free compressed air. Including 5 m cable. Special version Mobiflex 400-MS/BIA (215) Mobiflex 400-MS with BIA-W2 certificate 230V/1ph/50Hz ,00 Mobiflex 400-MS/C (215) Mobiflex 400-MS with integrated compressor 230V/1ph/50Hz ,00 Mobiflex 400-MS/C (235) Mobiflex 400-MS with integrated compressor 230V/3ph/50Hz+N ,00 Mobiflex 400-MS/C (435) Mobiflex 400-MS with integrated compressor 400V/3ph/50Hz+N ,00 Mobiflex 400-MS/C-BIA (215) Mobiflex 400-MS with compressor and BIA-W2 certificate 230V/1ph/50Hz ,00 9
12 Extraction arm/hose LFA 3.0 Flexible extraction arm 3 m ,00 4 LFA 4.0 Flexible extraction arm 4 m ,00 4 LFA 3.1 Ultraflexible extraction arm 3 m ,00 4 LFA 4.1 Ultraflexible extraction arm 4 m ,00 4 SUS 5/203 Extraction hose 5 m ,00 5 Extension hose (option; for SUS 5/203 only) EXS 5/203 Exhaust/extension hose 5 m ,00 Options and accessories (for LFA 3.0/4.0/3.1/4.1 only) WL Working light ,00 21 NCW 4 Connection wire 4 m ,00 23 WL+AST Working light + automatic start/stop ,00 21 NCW 4 Connection wire 4 m ,00 23 Replacement filters Pre filter Aluminium spark arrester ,00 24 FCC 30 Filter cartridge 30 m ,00 24 MOBIFLEX 300-E Mobile welding fume extractor with electrostatic filter Mobiflex 300-E (115) 115V/1ph/50Hz #N/B Mobiflex 300-E (215) 230V/1ph/50Hz ,00 Mobiflex 300-E (235) 230V/3ph/50Hz ,00 Mobiflex 300-E (435) 400V/3ph/50Hz ,00 Mobile welding fume extractor with electrostatic filter. Complete with metallic pre-imposed filter, ionizing cell and industrial collector cell. Filter surface area 14,2 m2. Fan 0,75 kw. Net extraction capacity 1300 m3/h. Including 5 m cable. Extraction arm/hose LFA 3.0 Flexible extraction arm 3 m ,00 4 LFA 4.0 Flexible extraction arm 4 m ,00 4 LFA 3.1 Ultraflexible extraction arm 3 m ,00 4 LFA 4.1 Ultraflexible extraction arm 4 m ,00 4 SUS 5/203 Extraction hose 5 m ,00 5 Extension hose (option; for SUS 5/203 only) EXS 5/203 Exhaust/extension hose 5 m ,00 Options and accessories (for LFA 3.0/4.0/3.1/4.1 only) WL Working light ,00 21 NCW 4 Connection wire 4 m ,00 23 WL+AST Working light + automatic start/stop ,00 21 NCW 4 Connection wire 4 m ,00 23 Activated carbon filter (option) SCF Activated carbon filter ,00 26 Replacement filters FIS Ionisation section electrostatic main filter ,00 25 FCS Collector section electrostatic main filter ,00 25 SAF Aluminium pre/final filter , ,00 SCF Activated carbon filter , ,00 10
13 Fans SF 1400 Extraction fan SF 1400 (115) 115V/1ph/50Hz ,00 SF 1400 (215) 230V/1ph/50Hz ,00 SF 1400 (235) 230V/3ph/50Hz ,00 SF 1400 (435) 400V/3ph/50Hz ,00 Fan 1400 m3/h free-blowing; 1400 rpm, 0,55 kw. For use in combination with one LTA 2.0 or LFA 2.0 (without filter unit). Silencer (option) SAS 160 Sound absorber 300 mm Ø 160 mm ,00 19 Motor protection switch MPS A Motor protection switch A 115V/1ph/50Hz ,00 22 MPS A Motor protection switch A 230V/1ph/50Hz ,00 22 MPS A Motor protection switch A 230V/3ph/50Hz ,00 22 MPS A Motor protection switch A 400V/3ph/50Hz ,00 22 Thermal relay NTR A Thermal relay A 115V/1ph/50Hz ,00 22 NTR A Thermal relay A 230V/1ph/50Hz ,00 22 NTR A Thermal relay A 230V/3ph/50Hz ,00 22 NTR A Thermal relay A 400V/3ph/50Hz ,00 22 SF 2400 Extraction fan SF 2400 (115) 115V/1ph/50Hz ,00 SF 2400 (215) 230V/1ph/50Hz ,00 SF 2400 (235) 230V/3ph/50Hz ,00 SF 2400 (435) 400V/3ph/50Hz ,00 Fan 2400 m3/h free-blowing; 2800 rpm, 0,75 kw. For use in combination with all arms, cranes and filter units. Silencer (option) SAS 160 Sound absorber 300 mm Ø 160 mm ,00 19 Motor protection switch MPS A Motor protection switch A 115V/1ph/50Hz ,00 22 MPS A Motor protection switch A 230V/1ph/50Hz ,00 22 MPS A Motor protection switch A 230V/3ph/50Hz ,00 22 MPS A Motor protection switch A 400V/3ph/50Hz ,00 22 Thermal relay NTR A Thermal relay A 115V/1ph/50Hz ,00 22 NTR A Thermal relay A 230V/1ph/50Hz ,00 22 NTR 3.0-4,7 A Thermal relay A 230V/3ph/50Hz ,00 22 NTR A Thermal relay A 400V/3ph/50Hz ,
14 SF 4200 Extraction fan SF 4200 RD (235) 230V/3ph/50Hz ,00 SF 4200 RD (435) 400V/3ph/50Hz ,00 SF 4200 LG (235) 230V/3ph/50Hz ,00 SF 4200 LG (435) 400V/3ph/50Hz ,00 Fan 3000 m3/h free-blowing; 2800 rpm, 1,5 kw. Recommended in configurations of 6-8 metres or with filter unit Statiflex 200-M, Statiflex 400-MS or Statiflex 300-E. Motor protection switch MPS A Motor protection switch A 230V/3ph/50Hz ,00 22 MPS A Motor protection switch A 400V/3ph/50Hz ,00 22 Thermal relay NTR A Thermal relay A 230V/3ph/50Hz ,00 22 NTR 3.0-4,7 A Thermal relay A 400V/3ph/50Hz ,00 22 SF 5500 Central extraction fan SF 5500 (235) 230V/3ph/50Hz ,00 SF 5500 (435) 400V/3ph/50Hz ,00 Fan 5500 m3/h free-blowing; 2800 rpm, 1,5 kw. For use in combination with 3-4 arms and/or cranes. Silencer (option) SAS 315 Sound absorber 500 mm Ø 315 mm ,00 19 Motor protection switch MPS A Motor protection switch A 230V/3ph/50Hz ,00 22 MPS A Motor protection switch A 400V/3ph/50Hz ,00 22 Thermal relay NTR A Thermal relay A 230V/3ph/50Hz ,00 22 NTR 3.0-4,7 A Thermal relay A 400V/3ph/50Hz ,00 22 SF 8000 Central extraction fan SF 8000 (235) 230V/3ph/50Hz ,00 SF 8000 (435) 400V/3ph/50Hz ,00 Fan 8000 m3/h free-blowing; 2800 rpm, 3,0 kw. For use in combination with 4-6 arms and/or cranes. Silencer (option) SAS 315 Sound absorber 500 mm Ø 315 mm ,00 19 Motor protection switch MPS A Motor protection switch A 230V/3ph/50Hz ,00 22 MPS A Motor protection switch A 400V/3ph/50Hz ,
15 SF Central extraction fan SF LI V/3ph/50Hz ,00 SF RI V/3ph/50Hz ,00 Central fan in sound absorbing case. Motor 7,5 kw, 2920 rpm. Capacity: 6000 m3/h at 3000 Pa, 7000 m3/h at 2550 Pa, m3/h at 1000 Pa. Incl. flexible adapters (inlet Ø 401 mm, outlet Ø 501 mm) and shock absorbers. SF LI: inspection cover left side SF RI: inspection cover right side Shown: SF LI Special version SF SF without sound absorbing case V/3ph/50Hz ,00 Frame SF LI/RI Mounting frame (for SF LI/RI only) ,00 Silencers SAS 500 straight Silencer straight Ø 500 mm ,00 19 SAS 500 elbow 90 Silencer elbow 90 Ø 500 mm ,00 19 Control FREQ 7,5 Frequency inverter 7,5 kw ,00 22 MSA 7.5 Motor starter 7,5 kw ,00 23 RC-MSA Remote control for MSA ,00 23 MSA 7.5 Motor starter 7,5 kw ,00 23 RC-MSA/T Remote control with timer for MSA ,00 23 SF Central extraction fan SF LI V/3ph/50Hz ,00 SF RI V/3ph/50Hz ,00 Central fan in sound absorbing case. Motor 11 kw, 2920 rpm. Capacity: 6000 m3/h at 3450 Pa, 7000 m3/h at 3400 Pa, m3/h at 1000 Pa. Incl. flexible adapters (inlet Ø 401 mm, outlet Ø 630 mm) and shock absorbers. SF LI: inspection cover left side SF RI: inspection cover right side Shown: SF LI Special version SF SF without sound absorbing case V/3ph/50Hz ,00 Frame SF LI/RI Mounting frame (for SF LI/RI only) ,00 Silencers SAS 630 straight Silencer straight Ø 630 mm ,00 19 SAS 630 elbow 90 Silencer elbow 90 Ø 630 mm ,00 19 Control FREQ 11 Frequency inverter 11 kw ,00 22 MSA 11 Motor starter 11 kw ,00 23 RC-MSA Remote control for MSA ,
16 Central filter systems STATIFLEX 6000-MS Central system with self-cleaning filter Statiflex 6000-MS (1) ,00 36 Statiflex 6000-MS (2) ,00 36 Statiflex 6000-MS (3) ,00 36 Statiflex 6000-MS (4) ,00 36 Central filter system suitable for 4500 to 9000 m3/h, depending on the application. Fully automatic filter cleaning by means of the RotaPulsePlus system. Suitable for filter FCC 150 or FCP 110. Connection for 6-7 bar of dry, oil-free compressed air. Inlet/outlet opening Ø 400 mm. Including 100 dm3 drum with wheels. Excluding control box, filter elements and air inlet module. Inlet Inlet 0 Air inlet module ,00 18 Inlet 90 Air inlet module ,00 18 Filter cartridge FCC 150 Cellulose filter cartridge (two-piece) 150 m ,00 25 FCP 110 Polyester filter cartridge (two-piece) 110 m ,00 25 Pre filter PSC Pre-separater ,00 24 Statiflex 300-2V Statiflex 300-2M without filters ,00 24 SAF Aluminium filter (2 per Statiflex 300-2V) ,00 24 Statiflex 300-2V Statiflex 300-2M without filters ,00 24 SOD Aluminium filter HD (2 per Statiflex 300-2V) ,00 24 Control box CB-6000-MS Control box ,00 21 CB-6000-MS/PLC Control box with PLC ,00 21 Single fans (max. 15) SF 2400 Fan 2400 m3/h free-blowing; 2800 rpm, 0,75 kw. 400V/3ph/50Hz ,00 11 SF 4200 Fan 3000 m3/h free-blowing; 2800 rpm, 1,5 kw. 400V/3ph/50Hz ,00 12 Central fan SF Fan without sound absorbing case 7.5 kw ,00 13 SF LI Fan; inspection cover left side 7.5 kw ,00 13 Frame SF LI/RI Mounting frame SF LI/RI ,00 17 SF RI Fan; inspection cover right side 7.5 kw ,00 13 Frame SF LI/RI Mounting frame SF LI/RI ,00 17 SF Fan without sound absorbing case 11 kw ,00 13 SF LI Fan; inspection cover left side 11 kw ,00 13 Frame SF LI/RI Mounting frame SF LI/RI ,00 17 SF RI Fan; inspection cover right side 11 kw ,00 13 Frame SF LI/RI Mounting frame SF LI/RI ,00 17 Silencer (option) SAS 500 straight Silencer straight SF ,00 19 SAS 500 elbow Silencer elbow 90 SF ,00 19 SAS 630 straight Silencer straight SF ,00 19 SAS 630 elbow Silencer elbow 90 SF ,
17 STATIFLEX 300-2E Stationary unit with electrostatic filter Industrial air cleaner with electrostatic filter. To be installed in ductwork or to be connected to extraction arm with fan. Including oil collector. Possibility to install an oil drainer. Filters included: 2x FIS and 2x FCS; pre and final filters to be ordered separately. No fan included. Max. filter capacity: 5000 m3/h. Filter surface area: 28,4 m2. The Statiflex 300-2E unit can be used for the extraction of oilmist, provided the suitable prefilter (2x SOD) and an oil drainer have been installed. *) Incl. 24V circuit. Airflow left-right: 230V/1ph/50Hz*) ,00 400V/3h/50Hz*) ,00 Airflow right-left: 230V/1ph/50Hz*) ,00 400V/3ph/50Hz*) #N/B STATIFLEX 300-3E Stationary unit with electrostatic filter Industrial air cleaner with electrostatic filter. To be installed in ductwork or to be connected to extraction arms with fan. Including oil collector. Possibility to install an oil drainer. Filters included: 3x FIS and 3x FCS; pre and final filters to be ordered separately. No fan included. Max. filter capacity: 7500 m3/h. Filter surface area: 42,6 m2. The Statiflex 300-3E unit can be used for the extraction of oilmist, provided the suitable prefilter (3x SOD) and an oil drainer have been installed. *) Incl. 24V circuit. Pre filters (Statiflex 300-2E: 2 pcs - Statiflex 300-3E: 3 pcs) Airflow left-right: 230V/1ph/50Hz*) #N/B 400V/3ph/50Hz*) #N/B 230V/1ph/50Hz*) #N/B 400V/3ph/50Hz*) #N/B SAF Aluminium pre/final filter ,00 24 SOD Demister for oilmist application ,00 24 Final filters (Statiflex 300-2E: 2 pcs - Statiflex 300-3E: 3 pcs) Airflow right-left: SAF Aluminium pre/final filter ,00 25 SSF Progressive synthetic filter; filter class G ,00 25 SCF Activated carbon filter; type RB ,00 26 SBF Synthetic bag filter; filter class F ,00 26 Connection pieces (Statiflex 300-2E only) RP Statiflex 300-2E to ducting Ø 400 mm ,00 18 RP x Statiflex 300-2E to ducting Ø 450 mm ,00 18 Options Oil drainer Oil drainer ,00 20 OG 50 Outlet grid Statiflex 300-2E ,00 20 Statiflex 300-2M Stationary unit with bag filter as final filter Statiflex 300-2E ,00 16 Statiflex 300-3M Stationary unit with bag filter as final filter Statiflex 300-3E #N/B 16 Replacement filters (Statiflex 300-2E: 2 pcs - Statiflex 300-3E: 3 pcs) SAF Aluminium pre/final filter ,00 24 SOD Demister for oilmist application ,00 24 FIS Ionisation section electrostatic main filter ,00 25 FCS Collector section electrostatic main filter ,00 25 SSF Progressive synthetic filter; filter class G ,00 25 SSF refill Refill SSF (filter without frame) ,00 25 SCF Activated carbon filter; type RB ,00 26 SBF Synthetic bag filter; filter class F ,
18 STATIFLEX 300-2M Stationary unit with mechanical bag filter. For light industrial welding applications like TIG welding. Can also be mounted after an Statiflex 300-2E unit as a guard filter. To be installed in ductwork or to be connected to extraction arm(s) with fan. Filters included: 2x SAF and 2x SBF. Max. filter capacity: 5000 m3/h. No fan included. Airflow left-right: Airflow right-left: , ,00 STATIFLEX 300-3M Stationary unit with mechanical bag filter. For light industrial welding applications like TIG welding. Can also be mounted after an Statiflex 300-3E unit as a guard filter. To be installed in ductwork or to be connected to extraction arm(s) with fan. Filters included: 3x SAF and 3x SBF. Max. filter capacity: 7500 m3/h. No fan included. Airflow left-right: Airflow right-left: #N/B #N/B Replacement filters (SFM 50: 2 pcs - SFM 75: 3 pcs) SAF Aluminium pre/final filter ,00 24 SBF Synthetic bag filter; filter class F ,
19 Fixing material, accessories for ducting and options Mounting material TMB ,00 Wall mounting bracket for installation of a fan on an extraction arm or extension crane. Including COK and hose clamp. LMB ,00 Wall mounting bracket for flexible arms. Consisting of wall bracket, flexible hose and connection piece for flexible arms. MBH ,00 Wall bracket for stationary mounting of a Miniflex. Frame SF LI/RI SF LI/RI ,00 Frame SF LI/RI SF LI/RI ,00 Carrying frame for central fan in sound absorbing box. Connection material RS 2 1,5 m ,00 Rail set to be mounted under a EC 2. Including rolls and fixing material. Max. load 50 kgs. NCF Connection flange incl. sealing and connection material. Ø mm ,00 CKS ,00 Connection kit stationary systems. For connection of a SF 2400 to a stationary filter system. Consisting of a flexible hose 1 m Ø 160 mm and two hose clamps. HC ,00 Hose clamp for connection of flexible hose Ø 160 mm to a flange. HCH ,00 Hose connection outlet side Miniflex for controlled discharge of filtered welding fume. 17
20 CP ,25 Connection piece for two hoses Ø 45 mm RP ,00 Connecting piece for SF 2400 to RP RP Ø 315 mm ,00 RP Ø 400 mm ,00 RP Ø 450 mm ,00 Connecting piece from Statiflex 300-E/M to ducting. Adapter ,00 Adapter to connect RP and RP Air inlet Statiflex 6000-MS INLET ,00 36 Air inlet module for determination of the air inlet direction. 0 = parallel with the outlet direction. For installation with central filter system Statiflex 6000-MS. INLET ,00 36 Air inlet module for determination of the air inlet direction. 90 = squared with the outlet direction. For installation with central filter system Statiflex 6000-MS. Valves and dampers NRV ,00 Non-return valve Ø 160 mm for SF 1400/2400. When using more fans at one central duct. NRV-HD ,00 Non-return valve Ø 160 mm. When using an Statiflex 200-M with two extraction arms. AD ,00 Automatic damper for ducting Ø 200 mm, for opening and closing of the ducting between the extraction arm and the central ductwork. Opens and closes in 8 seconds. Connection voltage: 24V/1ph/50-60Hz. 18
21 MD ,00 Manual damper to control the extraction volume per arm. To be used in central filter systems combined with a central fan. To be mounted in ductwork Ø 200 mm. MD ,00 Manual damper to control the extraction volume of a central fan combined with a central filter Statiflex MS. To be mounted in ductwork Ø 400 mm between filter and fan. Silencers SAS 160 SF 1400/ ,00 Sound absorbing set, consisting of silencer length 300 mm Ø 160 mm and 90 bend with two insert sleeves. SAS 315 SF 5000/ ,00 Sound absorbing set, consisting of silencer length 500 mm Ø 315 mm. SAS 500 straight SF LI/RI ,00 Silencer (straight) for mounting after central fan; connections with rubber sealing type KEN-LOK. Diameter: 500 mm interior. Insulation: length 1200 mm, diameter 735 mm. Sound reduction: 27 db(a) (indication only). SAS 630 straight SF LI/RI ,00 Silencer (straight) for mounting after central fan; connections with rubber sealing type KEN-LOK. Diameter: 630 mm interior. Insulation: length 1200 mm, diameter 880 mm. Sound reduction: 20 db(a) (indication only). SAS 500 elbow 90 SF LI/RI ,00 Silencer (elbow 90 ) to be used after central fan; connection with rubber sealing type KEN-LOK. Diameter: 500 mm interior. Insulation: radius 485 mm, diameter 735 mm. Sound reduction: 22 db(a) (indication only). SAS 630 elbow 90 SF LI/RI ,00 Silencer (elbow 90 ) to be used after central fan; connection with rubber sealing type KEN-LOK. Diameter: 630 mm interior. Insulation: radius 610 mm, diameter 880 mm. Sound reduction: 22 db(a) (indication only). Nozzles and hoses Miniflex NKT ,00 Nozzle kit with 2,5 m hose for standard welding gun; extraction above torch max. Ø 24,5 mm. 19
22 NKC ,00 Nozzle kit with 2,5 m hose for standard welding gun; extraction around torch max. Ø 27,5 mm. EN ,00 Funnel nozzle with magnetic foot and hose connection. EN ,00 Slit extraction nozzle 40 cm with magnetic foot and hose connection. H2.5/45 2,5 m ,00 H5.0/45 5,0 m ,00 Extraction/exhaust hose Ø 45 mm. Grids OG 25 S.300-1E/1M ,00 OG 50 S.300-2E/2M ,00 Outlet grid Push grid 110 x 610 mm ,00 Outlet grid including air volume control on behalf of push-pull system, for mounting in duct min. Ø 400 mm. Horizontally and vertically adjustable. Pull grid 110 x 610 mm ,00 Inlet grid on behalf of push-pull system, for mounting in duct min. Ø 400 mm. Vertically adjustable. Oil drainer Oil drainer S.300/H25/50-EF ,00 Oil drainer for draining oil from oil collector. 20
23 Electric components and accessories Working light + automatic start/stop WL ,00 Clear 35W/24V halogen lamp for mounting in the hood of the extraction arm. WL+AST ,00 Clear 35W/24V halogen lamp for mounting in the hood of the extraction arm with optical sensor for automatic start/stop. Not suitable for TIG welding. WCS ,00 Welding cable sensor to automatically switch on/off the connected extraction system. Suitable for stationary systems only. Options AST Automatic start/stop to be built in existing WL ,00 Control boxes CB ,00 Control box to control one fan and/or WL and/or AST, AD 200 and optional Statiflex 400-MS unit. To be used in combination with one thermal relay (NTR). Up to 3 kw. CB-WCS ,00 As CB; however, also suitable for connection of a WCS. CB-WCS ,00 Control box for automatic on/off switching of a central fan in welding fume extraction systems with max. 15 extraction arms provided with a WCS. Output signal: 4-20 ma. Particularly suitable for heavy applications and for TIG welding. Tension: 24V (for instance by PP 6). CB-6000-MS ,00 Control box to control max. four central filter systems Statiflex 6000-MS simultaneously. CB-6000-MS/PLC ,00 Control box with PLC to control a central filter systems Statiflex 6000-MS. Particularly suitable for use in pushpull systems. 21
24 CB-LDS ,00 Control box incl. frequency inverter for Lincoln Diluter System (LDS). FREQ 7.5 7,5 kw ,00 FREQ kw ,00 FREQ kw ,00 Frequency controller incl. power-line filter to regulate the extraction volume of a central filter system. Input signal coming from IF 15. Insulation class: IP 54. IF ,00 Interface for capacity control of SF and SF 15000, to control a frequency controller FREQ 7,5 or FREQ 11. Suitable for max. 15 extraction arms provided with CB and AD 200. Output signal 4-20 ma, depending on the number of extraction arms in use. MPS Motor protection switches Motor protection switch for fan. Wall-mounting. MPS A Motor protection switch A ,00 MPS A Motor protection switch A ,00 MPS A Motor protection switch A ,00 MPS A Motor protection switch A ,00 MPS A Motor protection switch A ,00 MPS A Motor protection switch A ,00 NTR Thermal relays Thermal relay for mounting in CB or CB-WCS. NTR A Thermal relay A ,00 NTR A Thermal relay A ,00 NTR A Thermal relay A ,00 NTR A Thermal relay A ,00 NTR A Thermal relay A ,00 NTR A Thermal relay A ,00 NTR A Thermal relay A ,00 22
25 LS 05 10E Price list (L19). Subject to modifications. TRK-200-M Transformer/relay kit Transformer/relay kit. To be installed in the Mobiflex 200-M in case a halogen lamp (WL) is required ,00 AEG NCW 4/11 Cable kits NCW 4 4 m ,00 NCW m ,00 Universal connection wire for connecting WL and AST. 4 m: mobile units 11 m: stationary units PP 6 Power supply PP ,00 Central power supply for max. 6 working lights WL or for a control box CB-WCS 15. Suitable for 400V/3ph/50-60Hz, 230V/1-3ph/50-60Hz, 115V/1ph/50-60Hz. MSA Motor starters MSA 7.5 7,5 kw ,00 MSA kw ,00 Motor starter for SF 12000/SF in conformity with European norms (including Germany). Includes motor protection switch, adjustable delay timer, transformer 24V and relay for potential-free contact. Metal casing 400x400x200 mm; IP 54. Wall mounting material included. The MSA can be connected to a potential-free contact of e.g. a welding robot, cutting table or automatic start/stop device (AST). RC-MSA ,00 Remote control for manual operation MSA 7.5/MSA 11. RC-MSA/T ,00 Remote control with timer for manual operation MSA 7.5/MSA 11. Pulley sets To reduce the air volume*) of a H25/50-EF unit for oil H25-EF ,00 mist application. Consists of a pulley type 118/20 and a V-belt SPZX 817. H50-EF ,00 *) H25-EF: 1800 m3/h; H50-EF: 3600 m3/h. 23
26 Replacement filters Pre filters Spark arrester ,00 Aluminium spark arrester for Mobiflex/Statiflex 200-M. Spark arrester ,00 Aluminium spark arrester for Mobiflex/Statiflex 400-MS. SAF ,00 Aluminium pre/final filter (filter class G2) ,00 SOD ,00 Demister for oilmist application. Dimensions frame: 480 x 450 x 50 mm. PF PHV ,00 Pre filter Miniflex; filter class G2 PSC ,00 Pre separator for sparks and large dust particles. For installation with central filter system Statiflex 6000-MS. Inlet opening Ø 630 mm. Outlet opening Ø 400 mm. Drum 100 dm3 with wheels included. Statiflex 300-1V + 2x SAF/2x SOD Statiflex 300-2V + 4x SAF/4x SOD Statiflex 300-3V + 6x SAF/6x SOD To be used as prefilter in central filter system with Statiflex 6000-MS #N/B #N/B #N/B Main filter FCC m ,00 Cellulose LongLife cartridge filter. To be used in Mobiflex/Statiflex 200-M. FCC m ,00 Cellulose cartridge filter with ExtraCoat treatment (filter class C). For To be used in Mobiflex 400-MS (BIA) and Statiflex 400-MS. 24
27 LongLife-H ,00 Disposable cartridge filter for Miniflex. With integrated 12 m 2 aluminium pre filter at the bottom FCC m ,00 Cellulose cartridge filter (two-piece) with ExtraCoat treatment to be used in central filter system Statiflex 6000-MS. FCP m ,00 Polyester cartridge filter (two-piece) with ExtraCoat treatment to be used in central filter system Statiflex 6000-MS. BIA class: USGC. FIS ,00 Industrial ionisation section for electrostatic main filter. FCS 14,2 m ,00 Collector section for electrostatic main filter. Cleaning material EFC Electrostatic filter cell cleaning solution for FIS and FCS. 4 x 5 litres ,00 WT 2 Cleaning box for FIS and FCS. 80 x 60 x 32 cm ,00 Final filters FAC 50 1,2 m ,00 Activated carbon filter for Mobiflex 200-M. To be placed at the outside of the filter FCC 50. SAF ,00 Aluminium pre/final filter; filter classe G ,00 SSF ,00 Progressive synthetic filter; filter class G3. Dimensions: , x 450 x 14 mm. SSF refill ,00 Refill SSF (filter without frame) SCF ,00 Activated carbon filter; type RB2. Dimensions: 480 x , x 14 mm. SBF ,00 Synthetic bag filter; filter class F8. Dimensions: frame 480 x 450 x 25 mm; depth filter bag 400 mm. 25
28 Statiflex 200-1M 938,00 Statiflex 200-2M 1.202,00 Statiflex 200-3M #N/B To be used as final filter after Statiflex 300-1E/2E/3E HEPA ,00 HEPA filter Miniflex; filter class H12. FAC HV ,00 Activated carbon filter Miniflex ,00 26
29 Multiple arm systems General The components mentioned below are required for Concept 1 to 4. Central filter system Statiflex 6000-MS Central filter system (1-4) 6.594,00 14 Inlet Air inlet module 0 /90 401,00 18 FCC 150 Filter cartridge ,00 25 PSC Pre separator ,00 24 CB-6000-MS Control box ,00 21 Extraction arms (max. 15) LTA 2.0 Telescopic arm ,00 3 LFA 2.0 Flexible extraction arm 2 m ,00 3 LFA 3.0 Flexible extraction arm 3 m ,00 4 LFA 4.0 Flexible extraction arm 4 m ,00 4 LFA 3.1 Ultraflexible extraction arm 3 m ,00 4 LFA 4.1 Ultraflexible extraction arm 4 m ,00 4 LFA 4.1-LowCeiling Ultraflexible extraction arm for low ceiling 4 m ,00 4 Option: extension crane EC 2 Extension crane (for LFA 3.0/4.0/3.1/4.1 only) 2 m ,00 5 EC 2 Extension crane (for LFA 3.0/4.0/3.1/4.1 only) 2 m ,00 5 EXT EC 4 Extension set to EC m ,00 Concept 1 Fully Controlled Multiple Fan System Central filter system for max. 15 extraction arms. In this system each extraction arm is provided with an individual fan, as a result of which the extraction volume per arm is always optimal. The system has a low energy consumption, because the fans are only running when actual welding takes place. In case the filtered air is exhausted to the atmosphere, it reduces the heat loss and is thus suitable to be used in countries with a mild/cold climate. The system can easily be extended with additional extraction arms/fans (max. 15). Single fans (max. 15) SF 2400 Fan 2400 m3/h free-blowing; 2800 rpm, 0,75 kw. 400V/3ph/50Hz ,00 11 NTR Thermal relay (400V/3ph/50Hz) ,00 22 SF 4200 Fan 3000 m3/h free-blowing; 2800 rpm, 1,5 kw. 400V/3ph/50Hz ,00 12 NTR Thermal relay (400V/3ph/50Hz) ,00 22 Wall brackets TMB For mounting LFA 3.0/4.0/3.1/4.1 + EC 2 + SF ,00 17 For mounting LFA 4.1-LC + SF 2400 LMB For mounting LFA 3.0/4.0/3.1/4.1 + SF 2400/ ,00 17 Additionally required NRV Non-return valve ,
30 Concept 1/AST Each arm is standard provided with a working light and an automatic start/stop device, which automatically switches on and off the fan. This system is controlled by an optical sensor mounted in the extraction hood. Due to this device, the welder is not bothered by any cable between the workpiece and the extraction arm. Fan on/off WL+AST Working light + automatic start/stop ,00 21 CB Control box ,00 21 NCW 11 Connection wire 11 m ,00 23 Concept 1/WCS Each arm is standard provided with a welding cable sensor, which automatically switches on and off the fan. This welding cable sensor is a sturdy and maintenance-free device. As an option, a working light can be mounted in the hood of the extraction arm. Fan on/off WCS Welding cable sensor ,00 21 CB-WCS Control box ,00 21 Option: working light WL Working light ,00 21 PP 6 Central power supply for max. 6x WL ,
31 Concept 2 Uncontrolled One Fan System Central filter system with a central fan for max. 8 extraction arms. The fan is provided with a motor starter with manual remote control. In this system all extraction arms are in use simultaneously. As an option, a working light can be mounted in the hood of the extraction arm. In case the filtered air is exhausted to the atmosphere, this system is suitable for countries with a mild/warm climate, in which heat loss is no matter. The system is relatively easy to install. Central fan + on/off SF LI/RI Fan 7,5 kw; inspection cover left/right side LI/RI 5.733,00 13 Frame SF LI/RI Mounting frame SF LI/RI ,00 17 MSA 7.5 Motor starter 7,5 kw ,00 23 RC-MSA Remote control for MSA ,00 23 SF LI/RI Fan 11 kw; inspection cover left/right side LI/RI 8.585,00 13 Frame SF LI/RI Mounting frame SF LI/RI ,00 17 MSA 11 Motor starter 11 kw ,00 23 RC-MSA Remote control for MSA ,00 23 Option: silencer SAS 500 straight Silencer straight SF LI/RI ,00 19 SAS 500 elbow 90 Silencer elbow 90 SF LI/RI ,00 19 SAS 630 straight Silencer straight SF LI/RI ,00 19 SAS 630 elbow 90 Silencer elbow 90 SF LI/RI ,00 19 Wall brackets TMB For mounting LFA 2.0/LFA 4.1-LC ,00 17 LMB For mounting LFA 3.0/4.0/3.1/ ,00 17 Option: working light WL Working light ,00 21 PP 6 Central power supply for max. 6x WL ,00 23 CB-6000-MS/PLC instead of CB-6000-MS Control box with PLC ,00 21 RC-MSA/T instead of RC/MSA Remote control with timer for MSA ,00 23 Additionally required NCF Connection flange (not necessary for LTA 2.0 and EC 2/4) ,00 17 MD 200 Manual damper Ø 200 mm ,
32 Concept 3 Semi-controlled One Fan System Central filter system with a central fan for max. 15 extraction arms. The extraction arms are connected to a central fan, which automatically starts running when the first welder starts and switches off when the last one is finished. Thanks to automatic dampers in each arm, combined with the specific characteristics of the fan, the volume of extracted air is adjusted to the number of extraction arms in use. This system reduces the heat loss in case of exhaust of the filtered air to the atmosphere and is thus suitable for countries with a mild/cold climate. Central fan SF LI/RI Fan 7,5 kw; inspection cover left/right side LI/RI 5.733,00 13 Frame SF LI/RI Mounting frame SF LI/RI ,00 17 MSA 7.5 Motor starter 7,5 kw ,00 23 SF LI/RI Fan 11 kw; inspection cover left/right side LI/RI 8.585,00 13 Frame SF LI/RI Mounting frame SF LI/RI ,00 17 MSA 11 Motor starter 11 kw ,00 23 Option: silencer SAS 500 straight Silencer straight SF LI/RI ,00 19 SAS 500 elbow 90 Silencer elbow 90 SF LI/RI ,00 19 SAS 630 straight Silencer straight SF LI/RI ,00 19 SAS 630 elbow 90 Silencer elbow 90 SF LI/RI ,00 19 Wall brackets TMB For mounting LFA 2.0/LFA 4.1-LC ,00 17 LMB For mounting LFA 3.0/4.0/3.1/ ,00 17 Additionally required NCF Connection flange (not necessary for LTA 2.0 and EC 2/4) Ø mm ,00 17 MD 200 Manual damper Ø 200 mm ,00 19 AD 200 Automatic damper Ø 200 mm ,00 18 Concept 3/AST Each arm is standard provided with a working light. The automatic start/stop device is controlled by an optical sensor mounted in the extraction hood. Central fan on/off WL+AST Working light + automatic start/stop ,00 21 CB Control box ,00 21 NCW 11 Connection wire 11 m ,
33 Concept 3/WCS The automatic start/stop device is controlled by a sturdy and maintenance-free welding cable sensor. As an option, a working light can be mounted in the hood of the extraction arm. Central fan on/off WCS Welding cable sensor ,00 21 CB-WCS 15 Control box for max. 15x WCS ,00 21 PP 6 Power supply for CB-WCS ,00 23 Option: working light IF 15 Instead of CB-WCS ,00 22 WL Working light ,00 21 CB-WCS Control box ,00 21 NCW 11 Connection wire 11 m ,00 23 Concept 4 Fully Controlled One Fan System Central filter system with a central fan for max. 15 extraction arms. Each arm is provided with an automatic damper. The extraction arms are connected to a central fan, which automatically starts running when the first welder starts and switches off when the last one is finished. The fan is connected to a frequency inverter, which exactly adjusts the extraction volume to the number of extraction arms in use. This has a favourable effect to the sound level. This system reduces the heat loss in case of exhaust of the filtered air to the atmosphere and is thus suitable for countries with a mild/cold climate. Central fan SF LI/RI Fan 7,5 kw; inspection cover left/right side LI/RI 5.733,00 13 Frame SF LI/RI Mounting frame SF LI/RI ,00 17 IF 15 Interface for capacity control ,00 22 FREQ 7.5 Frequency inverter 7,5 kw ,00 22 SF LI/RI Fan 11 kw; inspection cover left/right side LI/RI 8.585,00 13 Frame SF LI/RI Mounting frame SF LI/RI ,00 17 IF 15 Interface for capacity control ,00 22 FREQ 11 Frequency inverter 11 kw ,00 22 Option: silencer SAS 500 straight Silencer straight SF LI/RI ,00 19 SAS 500 elbow 90 Silencer elbow 90 SF LI/RI ,00 19 SAS 630 straight Silencer straight SF LI/RI ,00 19 SAS 630 elbow 90 Silencer elbow 90 SF LI/RI ,00 19 Wall brackets TMB For mounting LFA 2.0/LFA 4.1-LC ,00 17 LMB For mounting LFA 3.0/4.0/3.1/ ,00 17 Additionally required NCF Connection flange (not necessary for LTA 2.0 and EC 2/4) ,00 17 MD 200 Manual damper Ø 200 mm ,00 19 AD 200 Automatic damper Ø 200 mm ,
34 Concept 4/AST Each arm is standard provided with a working light. The automatic start/stop device is controlled by an optical sensor mounted in the extraction hood. Central fan on/off WL+AST Working light + automatic start/stop ,00 21 CB Control box ,00 21 NCW 11 Connection wire 11 m ,00 23 Concept 4/WCS The automatic start/stop device is controlled by a sturdy and maintenance-free welding cable sensor. As an option, a working light can be mounted in the hood of the extraction arm. Central fan on/off WCS Welding cable sensor ,00 21 CB-WCS 15 Control box for max. 15x WCS ,00 21 PP 6 Power supply for CB-WCS ,00 23 Option: working light IF 15 Instead of CB-WCS ,00 22 WL Working light ,00 21 CB-WCS Control box ,00 21 NCW 11 Connection wire 11 m ,
35 General filtration LDS Lincoln Diluter System Description Central filter system with a capacity of max m3/h. Prevents accumulation of welding fume by continuous filtration of polluted air. Keeps the background concentration of welding fume below the legally prescribed level. Optimizes the disposal of welding fume by existing (natural) and forced ventilation. No ducting required. Induction factor: 22 Volume of air in motion: m3/h Throw: max. 50 m Components Statiflex 6000-MS/D Central filter unit ,00 FCC 150 Cellulose filter cartridge 150 m ,00 25 CB-LDS Control box, incl. frequency inverter ,00 22 Diluter Outlet unit with 6 adjustable nozzles ,00 CK-LDS Fixing material ,00 SF RI Fan in sound absorbing case ,
36 P-P Push-pull system U system Parallel system Description A push-pull system is a method of general filtration meant to prevent accumulation of welding fume in a workshop. It consists of ductwork provided with grids, one or two fans and one or two filter systems. The ductwork is installed at the height of the welding fume layer (4-6 m). In this way the welding zone is "enclosed" by the ducting. At one side of the ductwork the air is extracted ("pull") by the grids, filtered and blown out ("push") through the fan by way of the grids of the outlet duct. In this way a continuous air circulation is generated. The welding fume is constantly and efficiently removed and the background concentration of welding fume in the facility stays below the legally prescribed level. A push-pull system can be installed as a U system or as a parallel system. A combination of systems might be required to cover the entire welding zone within the facility. Filter unit Statiflex 6000-MS Central filter system (1-4) 6.594,00 14 Inlet Air inlet module 0 /90 401,00 18 FCC 150 Filter cartridge 150 m ,00 25 CB-6000-MS/PLC Control box with PLC ,00 21 Fan SF LI/RI Fan in sound absorbing case LI/RI 5.733,00 13 Frame SF LI/RI Mounting frame SF LI/RI ,00 17 MSA 7.5 Motor starter 7,5 kw ,00 23 RC-MSA/T Remote control with timer for MSA ,00 23 Silencer SAS 500 straight Silencer straight SF LI/RI ,00 19 SAS 500 elbow 90 Silencer elbow 90 SF LI/RI ,00 19 Inlet and outlet grids Push Grid Outlet grid ,00 20 Pull Grid Inlet grid ,
37 H25-EF Industrial air cleaner with electrostatic filter Industrial air cleaner with electrostatic filter and integrated fan. For mounting to wall or ceiling. Including oil collector and motor protection switch. Filters included: FIS and FCS; pre and final filters to be ordered separately). Fan capacity: 0,75 kw. Max. extraction capacity: 2500 m3/h. Filter surface area: 14,2 m2. The H25-EF unit can be used for the extraction of oilmist, provided the suitable prefilter (SOD), an oil drainer and another pulley set have been installed. *) Incl. 24V circuit. Airflow left-right: 230V/1ph/50Hz*) ,00 400V/3ph/50Hz*) ,00 Airflow right-left: 230V/1ph/50Hz*) ,00 400V/3ph/50Hz*) ,00 H50-EF Industrial air cleaner with electrostatic filter Pre filters (H25-EF: 1 pcs - H50-EF: 2 pcs) Industrial air cleaner with electrostatic filter and integrated fan. For mounting to wall or ceiling. Including oil collector and motor protection switch. Airflow left-right: Filters included: 2x FIS and 2x FCS; pre and final filters to 230V/1ph/50Hz*) ,00 be ordered separately). Fan capacity: 1,5 kw. Max. extraction capacity: 5000 m3/h. 230V/3ph/50Hz*) ,00 Filter surface area: 28,4 m2. The H50-EF unit can be used for the extraction of oilmist, 400V/3ph/50Hz*) ,00 provided the suitable prefilter (2x SOD), an oil drainer and another pulley set have been installed. *) Incl. 24V circuit. Airflow right-left: 230V/1ph/50Hz*) ,00 230V/3ph/50Hz*) ,00 400V/3ph/50Hz*) ,00 SAF Aluminium pre/final filter ,00 24 SOD Demister for oilmist application ,00 24 Final filters (H25-EF: 1 pcs - H50-EF: 2 pcs) SAF Aluminium pre/final filter ,00 25 SSF Progressive synthetic filter; filter class G ,00 25 SCF Activated carbon filter; type RB ,00 26 Options Oil drainer Oil drainer ,00 20 Pulley set To reduce the air volume for oil mist application H25-EF ,00 23 H50-EF ,00 23 Replacement filters (H25-EF: 1 pcs - H50-EF: 2 pcs) SAF Aluminium pre/final filter ,00 24 SOD Demister for oilmist application ,00 24 FIS Ionisation section electrostatic main filter ,00 25 FCS Collector section electrostatic main filter ,00 25 SSF Progressive synthetic filter; filter class G ,00 25 SSF refill Refill SSF (filter without frame) ,00 25 SCF Activated carbon filter; type RB ,
38 Filter selection Annual consumption of welding wire per workplace Welding of oil-treated metal TIG welding MIG/MAG solid wire < 700 kg MIG/MAG flux cored wire < 500 kg rutile electrodes < 500 kg basic electrodes < 500 kg MIG/MAG solid wire > 700 kg MIG/MAG flux cored wire > 500 kg rutile electrodes > 500 kg basic electrodes > 500 kg Stationary Statiflex 300-1E Statiflex 200-M Statiflex 200-M Statiflex 400-MS Mobile Mobiflex 300-E Mobiflex 200-M Mobiflex 200-M Mobiflex 400-MS Central Statiflex 300-2E Statiflex 6000-MS Statiflex 6000-MS Statiflex 6000-MS Selection wall bracket Central fan SF 2400 SF 4200 LTA TMB - LFA 2.0 TMB TMB TMB LFA 3.0 LMB LMB LMB LFA 4.0 LMB LMB LMB LFA 3.1 LMB LMB LMB LFA 4.1 LMB LMB LMB LFA 4.1-LC TMB TMB TMB EC 2 - TMB - 36
39 Selection single fan LTA 2.0 LFA 2.0 LFA 3.0/3.1 LFA 4.0/4.1/4.1-LC LFA 3.0/3.1 + EC 2 LFA 4.0/4.1 + EC 2 LFA 3.0/3.1 + EC 4 LFA 4.0/4.1 + EC 4 No filter SF 2400 Statiflex 200-M/300-E/ 400-MS SF 1400 SF 2400 SF 2400 SF 2400 SF 2400/SF 4200 SF 4200 Statiflex 6000-MS SF 4200 SF 4200 SF 2400/SF 4200 SF 4200 SF 4200 Selection central fan Extraction volume per arm: approx m3/h Extraction arms without automatic dampers LTA 2.0 LFA 2.0 LFA 3.0/3.1 LFA 4.0/4.1/4.1-LC LFA 3.0/3.1/4.0/4.1 + EC 2 LFA 3.0/3.1/4.0/4.1 + EC 4 Systems without filter SF SF SF SF Systems with filter; exhaust to atmosphere 2x SF x SF 4200 Statiflex 300-1E SF 8000 Statiflex 300-2E Statiflex 300-3E SF Statiflex 6000-MS SF Statiflex 6000-MS Systems with filter; recirculation SF 5500 Statiflex 300-1E SF 8000 Statiflex 300-2E Not recommended Statiflex 300-3E SF Statiflex 6000-MS SF Statiflex 6000-MS
40 Selection multiple arm system with Statiflex 6000-MS Characteristics: Concept AST WCS AST WCS AST WCS Max. number of arms Sturdiness Working light standard option option standard option standard option TIG Extraction individual fans central fan central fan central fan Control Sound level Energy-saving Flexibility Installation cost Selection airflow Statiflex 6000-MS Selection SF LI/RI Inlet 0 Inlet 90 1 SF 12000/ LI RI 3 4 Indication duct diameter Duct diameter Ø 160 mm Extraction arm no. 0 Ø 200 mm 1 Ø 250 mm 2 Ø 315 mm 3-4 Ø 400 mm 4-7 Ø 500 mm 7-10 Ø 630 mm
41 Product overview 39
42 Overview fan control 40
LINCOLN ENVIRONMENTAL SYSTEMS
LINCOLN ENVIRONMENTAL SYSTEMS Low-Vacuum Solutions ProSource LV s ProSource LOW VACUUM SOLUTIONS PAGE NO. MOBILE SYSTEMS Mobiflex 100-NF Portable Fan...3 Mobiflex 200-M: Mobile Fan, Filtration & Extraction
More informationFUME DOESN T STAND A CHANCE
FUME DOESN T STAND A CHANCE WELD FUME CONTROL Top Image: Statiflex 200-M Dual Arm with Fan Units and Extraction Arms Bottom Image: Statiflex 400-MS with Extraction Arm and Fan Unit Statiflex Wall-Mounted
More informationPRODUCT GUIDE Version 2004:02 For a better workbench environment
PRODUCT GUIDE Version 2004:02 For a better workbench environment FILTRONIC AB Box 2284, SE-531 02 LIDKÖPING SWEDEN Tel +46 (0)510-208 10, Fax +46 (0)510-201 40 e-mail: office@filtronic.se www.filtronic.se
More informationSoldering/Desoldering. Convection Rework. Fume Extraction. Fluid Dispensing
Soldering/Desoldering Convection Rework Fume Extraction Fluid Dispensing www.beasuperproducer.com BVX-100 Benchtop Single User Arm/Plenum System Portable, single user fume extraction system Low noise unit
More informationSECTION WELDING FUME EXHAUST SYSTEM
SECTION 233500 WELDING FUME EXHAUST SYSTEM PART 1 - GENERAL 1.1 WORK INCLUDES Welding fume exhaust system and controls Accessories Additional System Equipment Engineering Support Commissioning 1.2 RELATED
More informationCompact Vacuum Systems
Compact Vacuum Systems 6 Compact Vacuum Systems DC 11-Module The DC 11-Module is a complete central unit for source extraction and industrial cleaning. The unit can manage just about every kind of dust
More information5 Compact Vacuum Systems. Compact Vacuum Systems
Compact Vacuum Systems Compact Vacuum Systems 7 Compact Vacuum Systems DC 11-Module The DC 11-Module is a complete central unit for source extraction and industrial cleaning. The unit can manage just about
More informationProduct manual Extraction arm KUA
Product manual Extraction arm KUA Table of contents: Page: Technical description...2 Delivery...2 Advantages...2 Technical data...2 Components and operation...2 Handling...2 Hood operation...2 Mounting
More informationFilterMax F. Modular dust collector with integrated pre-separator. Models
Technical leaflet 988010 10 1 Date 2009-11-02 FilterMax F Modular dust collector with integrated pre-separator FilterMax F is a complete filter solution for the entire workshop. With it s integrated preseparator
More informationBench Top Extraction Arms
Bench Top Extraction Arms The Nederman BenchTop arms can be used in every type of environment, ranging from assembly stations, where solder fumes are extracted, to laboratories, where protection against
More informationFilterMax DF. Modular dust multi purpose collector. Models
Modular dust multi purpose collector FilterMax DF is a efficient and compact solution to your dust and fume problems. FilterMax DF handles the air polution from metal industries as well as non explosive
More informationfilter replacement Easy guide to identify filter cartridges.
filter replacement Easy guide to identify filter cartridges. Filter replacement (CART filter) of the MultiDust Bank content Stationary welding fume filters 2 Mobile units 3 Portable welding fume extractor
More informationAPPENDIX A 30 WELDING BOOTHS AND FUME EXHAUST SYSTEM
APPENDIX A 30 WELDING BOOTHS AND FUME EXHAUST SYSTEM The Technology Center of DuPage is seeking bids for thirty (30) welding booths with fume exhaust system as described below. Companies or individuals
More informationImproving your workspace
FILTERMAX DF FilterMax DF is a efficient and compact solution to your dust and fume problems. FilterMax DF handles the air polution from metal industries as well as non explosive dust from other industries.
More informationFilterMax DF. Modular dust multi purpose collector. Models
Technical leaflet 988009 10 1 Date 2009-10-26 FilterMax DF Modular dust multi purpose collector FilterMax DF is a efficient and compact solution to your dust and fume problems. FilterMax DF handles the
More informationNCF fans 50 Hz. Protection class IP 55
The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.
More informationSYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT
136 SYSTEMS FOR VEHICLE TESTING SYSTEMS REV M KIT AND REV A KIT Extraction kits for testing centres for cars, light commercial vehicles and heavy vehicles with manual or automatic return system Equipments
More informationFilterBox Wall. Automatically or manually cleaned for dust & fume applications.
Automatically or manually cleaned for dust & fume applications. FilterBox Wall can come with or without a attached. The models without a are suitable for installations with an external and contactor, and
More informationAbout Dustcontrol Filter Units
An extraction system should always be equipped with a filter unit. The filter unit separates coarse material in the cyclone body of the unit and fine dust in an internal arrangement of conical pleated
More informationFILTER Pure advantage. A flexible modular filter for particles and gas
A flexible modular filter for particles and gas The MOVEX modular filter CV with its sturdy profile allows the possibility to satisfy the need of several functions in one product. The filter in its basic
More informationFILTER MODULES FILTER MODULES APPLICATIONS
FILTER MODULES FILTER MODULES APPLICATIONS MF MF filter modules were developed for use as filtration systems in centralised systems or individual work stations for the extraction of welding fumes. They
More informationEDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM
AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 0 015982 603071 Installation examples Ceiling or wall mounting Extract ventilation through short duc extract ventilation Extract ventilation
More informationProduct catalogue 2010
Product catalogue 2010 welding, cutting and more... www.kemper.eu KEMPER Filter-Cell KEMPER Filter-Cell... 85 KEMPER Filter-Cell XL... 86 Accessories and spare parts... 87 84 KEMPER Filter-Cell The KEMPER
More informationProduct manual Junior LM-2
Product manual Junior LM-2 Table of contents: Page: Technical description... 2 Delivery... 2 Advantages... 2 Technical data... 2 Construction and function... 2 Handling... 2 Hood operation... 2 Mounting
More informationNCF 60 Hz. Protection class IP 55
The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.
More informationAbout Vacuum Producers
Vacuum Producers About Vacuum Producers The heart of the system The vacuum producer is the heart of the system. Here the negative pressure is created that drives the system. In Dustcontrol extraction systems,
More informationCentrifugal performance characteristics with axial flow pattern: RADAX VAR
High pressure in-line mixed-flow fans RADAX VAR Centrifugal performance characteristics with axial flow pattern: RADAX VAR COMPACT PRESSURE-RESISTANT UNIVERSAL In their compact casing, the RADAX VAR impellers
More informationGigaBox centrifugal fans Product specific information
GigaBox centrifugal fans Product specific information GigaBox and accessories Wall bracket GB-WK (ccessories) Outdoor cover hood GB-WSD (ccessories) Included in delivery: a) Flexible sleeve b) Outlet spigot,
More informationFilters for fixed installations
CYCLONE FU MECHANICAL FILTERS The FU are especially intended for filtration of dusts and heavy particles bigger than 5 microns. Centrifugal filtration is used for grinding, sanding, oxycut, all heavy,
More informationCATALOG 2017
www.hpschou.com CATALOG 2017 PRESENTS A RANGE OF TOOLS Introducing the new Probuilder Power-tool concept The new Probuilder concept, one 18 V lithium battery platform for all Power-tools, designed for
More information(ULT200-UM.x-HFM050) Technical Documentation
SRA200.x-01 (ULT200-UM.x-HFM050) Technical Documentation Date of issue: 07 / 2010 clean air, strong performance SRA-series, modular air extraction and filtration units for Air handling equipment for environmental
More informationDESKTOP CONTAINMENT SYSTEM
AIR TECHNOLOGIES INC. BRATIN LE OF EX CE G CE Solder and Waxing Fumes Conformal Coating Vapors Reflow Oven Exhaust Wave Soldering Exhaust Dedrossing Solvent Vapors Laser Cutting & Marking CELLE 1991-2
More informationPowerful. Efficient. RED. Look to Micro Air Dust Collectors for clean air and cost-effective operation.
Powerful. Efficient. RED. Look to Micro Air Dust Collectors for clean air and cost-effective operation. Unmatched Cleaning Efficiency Micro Air dust collectors are engineered for powerful filtration at
More informationLCP Cartridge Dust Collector
Cartridge collectors designed for continuous operation in process and general extraction applications with free flowing. LCP cartridge collectors designed for continuous operation in process and general
More informationhore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE CENTRIFUGAL FANS ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 73-16 CENTRIFUGAL FANS CONTENT PAGE 1. CENTRIFUGAL
More informationThe future of wet and dry vacuum cleaning
VL500 is ideally suited for hotels, contract cleaners, education, exhibition and conference centers as well as public buildings, manufacturing and industrial applications. A failsafe filter design makes
More information1 AIR HANDLING UNIT TYPE AIR ACCESS 75
SUPPLY 1 AIR HANDLING UNIT TYPE AIR ACCESS 75 Location : EXTERNAL Position : SIDE BY SIDE SLIDING PANELS for COMPLETE ACCESSIBILITY MULTI SERVICE BULKHEAD for HYDRAULIC AND ELECTRICAL CONNECTIONS Self-supporting
More informationARTICULATED EXTRACTION ARMS ARMOFLEX ARMOTECH 03-05 06-08 PORTABLE UNITS PORTABLE EXTRACTION UNIT FACILE 26-28 IBS PAB 09-11 12-13 PORTABLE UNITS AER 101 AER 102 29-30 31-32 WALL-MOUNTED PURIFICATION SYSTEM
More informationEngineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h
Engineering Data Manual New : available with EC motor VH High Static Pressure Ductable Fan Coil Unit Models 07 to 27 800 to 4650 m 3 /h General Characteristics Presentation On model VH 07, coils have 4
More informationPortable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration
-MC -MC Diversified Air Systems, Inc. pantone 2756 Portable filtration unit / 650 CFM (305 L/s) pantone 2756 Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration 99.9% efficiency
More informationSF-1000 workbench - welding table. User s Manual.
SF-1000 workbench - welding table User s Manual - 2 - SF-1000 workbench About this document 3 Graphic symbols 3 Equipment arrival 4 Product application 4 Construction 4 Technical data and dimension 5 Arm
More informationPRODUCT GUIDE. For a better workbench environment!
PRODUCT GUIDE FILTRONIC Box 2284 SE- 531 02 LIDKÖPING Tel. +46 510 208 10 Fax. +46 510 201 40 office@filtronic.se www.filtronic.se For a better workbench environment! Content High airflow systems 3-7 MG-series...
More informationOperating instructions
Operating instructions Type TEKA filtoo TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72 E-Mail:
More informationAccessories. Series REC
Accessories Series REC 5-7-9 ACCESSORIES REC Series RBA BAF RBE CV3 PC3 SRE PSD CSA GIU TPA O. REC 5 REC 5-6 - 5BT11 5BT6 1CO71 1CO73 1SE96 5PR 1KR6 5SU137 5TE1 REC 5-12 5BT12 5BT122 5BT121 1CO71 1CO73
More informationBall-bearing KUA. A superflexible extractor for small and medium sized work places
Ball-bearing KUA A superflexible extractor for small and medium sized work places Copyright. All rights reserved. PLYMOVENT AB Föreningsgatan 37, SE-211 52 Malmö, Sweden Tel: +46 40 30 31 30, Fax: +46
More informationRS SERIES. Two Stage Progressive Gas Burners FIRING RATES
The RS burners series covers a firing range from 44 to 2290 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation
More informationAir Boss M-Series Media & Adsorption Air Cleaner
Air Boss M-Series Media & Adsorption Air Cleaner A i r P u r i f i c a t i o n S y s te m s w w w. t r i o n i a q. c o m Engineered Solutions For Clean Air TRION s Air Boss media units are industrial
More informationRS/M SERIES. Modulating Gas Burners FIRING RATES
The RS/M burners series covers a firing range from 45 to 2650 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation
More informationTHE WORLD OF EXTRACTION. Series EXTRACTION TECHNOLOGY FOR MAXIMUM EFFICIENCY
Series EXTRACTION TECHNOLOGY FOR MAXIMUM EFFICIENCY THE SERIES REDEFINING EFFICIENCY The devices in the series set new standards for energy-efficient extraction systems. The series provides the ideal balance
More information(ULT300-UM.x-HFM050) Technical Documentation
LAS300.x-01 (ULT300-UM.x-HFM050) Technical Documentation Date of issue: 08 / 2010 clean air, strong performance LAS-series, modular air extraction and filtration units for Air handling equipment for environmental
More informationINDUSTRY COMBO MF. Combined filter modules for fumes and particulate, combined composition of multiple modules to increase filtering capacity
INDUSTRY Technical data sheet FILTER MODULES COMBO MF Combined filter modules for fumes and particulate, combined composition of multiple modules to increase filtering capacity APPLICATIONS The COMBO MF
More informationFume extractor is warranted for two years, parts and labor.
Industrial Centralized Systems Issued Feb. 7 Index No. AY/. Welding Safety and Health Quick Specs Industrial Applications Manufacturing and fabrication Schools and training centers Processes Stick (SMAW)
More informationPortable filtration unit / 650 CFM (1100 M3H) Portable filtration unit / 1500 CFM (2550 M3H) For 2 arm configuration
AQC source capture equipment March 27, 2008 version. Leaflet under construction. More information to come at a later date. Portable filtration unit / 650 CFM (1100 M3H) Portable filtration unit / 1500
More informationVARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.
VARIO VARIO Separation of fine dust particles The VARIO series is particularly suitable for separation of fine dust. The VARIO units are of modular construction in order to meet different requirements,
More informationIndustrial automatic self-cleaning filters made in stainless steel AISI 316
Industrial automatic self-cleaning filters made in stainless steel AISI 316 FilBlue Introduction The automatic industrial selfcleaning filters are designed to remove all suspended solids from surface water
More informationWeld filter C10. Weld filter C20. Easy to move and position. Includes 3 m long extraction arm, Original. Cleanable filter with high filtration
Weld filters C0 and C0 Mobile extraction/filter units The obile Weld units C0 and C0 are used for the extraction and filtration of lighter welding fues. Weld filter C0 Easy to ove and position. Includes
More informationExhaust rail system 920 for stationary vehicles
Easy to handle systems for all types of workshops. Consists of a basic rail system which is completed with an exhaust extraction kit. Very high extraction efficiency. One extraction unit can serve several
More informationTRIMMING TECH 90. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech90. CND code: W CIVAB code:
IVD In vitro diagnostic-medical device CND code: W0202059016 - CIVAB code: TRIMMING TECH 90 General information Type of instrument: Aspirated hood for histology. Model: Trimming Tech 90. Code: Description:
More informationH) OIL MIST FILTRATION
H) OIL MIST FILTRATION H Oil mist filtration H-1 Preface H-2 FMBHP/C oil mist bag mechanical filter and AZUR cartridges H-3 AZUR 3.0/5.0 EH oil m ist electrostatic filters 216/265 CE compliance H: Oil
More informationExhaust Extraction Systems for Stationary Vehicles
Exhaust Extraction Systems for Stationary Vehicles The systems presented in this section are used for extracting exhaust from parked vehicles. All solutions offer simple installation and optimal extraction
More informationIndustrial vacuum cleaners
Basic 3Phase I-Vac (T40W) and specific B&C (T40WP) versions with SC blower. T40W is a mobile I-vac for liquid&solid. Available with a 100L or 50L bin & as well as with a Gravity Unload system (GU) for
More informationCBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.
LOW PRESSURE CENTRIFUGAL FANS CBM Small Series Range of single and double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel and protected against corrosion by a
More informationThe Anatomy of a Drum Filter
The Anatomy of a Drum Filter Theory of Operation Dirty air is introduced into the Drum Filter Enclosure The Main System Fan pulls the air across the filter media The dirty particles are vacuumed off the
More informationEDM-80N EDM-80L EDM-100 EDM-200. Installation examples. Extract ventilation through short duc
AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 Ceiling or wall mounting extract ventilation Extract ventilation through wall or using a shunt duct system All V models incorporate all accessories
More informationRS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES
The RS/E-EV MZ burners series covers a firing range from 44 to 2650 kw, and it is based on a new Digital Burner Management System, Riello REC27, which is able to manage the air-fuel ratio by independent
More informationProduct catalogue 2010
Product catalogue 2010 welding, cutting and more... www.kemper.eu BG-PRÜFZERT BGIA Gefahrstoff geprüft Schweißrauchklasse W3 Mobile filter units Selection criteria for mobile filter equipment... 49-50
More informationDUST COLLECTORS. Stronger. Better. CLEANER.
DUST COLLECTORS Stronger. Better. CLEANER. Stronger. Better. CLEANER. Micro Air FORCE Dust Collectors The Next Generation Of CLEAN Air Systems Unrivaled Cleaning Technology FORCE Dust Collectors are designed
More informationRS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS
The RS/1 series of burners covers a firing range from 70 to 550 kw, and they have been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers.
More informationContent 1. Laserline series 3
FT LASERLINE Series TECHNICAL DATA SHEET FT LASERLINE Series 1. Laserline series Content 1. Laserline series 3 2. Connectors 4 3. Control system 4 4. Options 5 4.1 Automatic flow control 5 4.2 FT communication
More informationCYCLONE F 400 smoke extraction casing
Fire protection CYCLONE F smoke extraction casing Presentation of the CYCLONE F range (12) WHY CHOOSE A CYCLONE F? In order to fulfil the requirements of the CE markings (EN 1211-3 and the French governmental
More information[Small diaphragm vacuum pumps]
[Small diaphragm vacuum ] The small vacuum shown on this page produce vacuum using a diaphragm. They can be used either as vacuum pump or as a small compressor, and they are able to deliver 100% oil-free
More informationProduct information: Obel-P Flow Coater
Product information: Obel-P Flow Coater Obel-P Automation produces a wide range of flow coaters which are shortly described in this product information. The machine described is for windows with max. dimensions
More informationCommercial Vacuum Cleaners
Cleaning in crowded areas The obvious choice for vacuum cleaning in theatres, cinemas, shops, coaches and aircraft and a great complementary duster. Nilfisk makes cleaning in hard-to-navigate places easy.
More informationWeighfeeders SITRANS WW200
Introduction Overview is a low- to medium-capacity weighfeeder used for minor ingredient additives. Benefits High accuracy Ideal for low- to medium-capacity loads Fast installation, easy to clean and maintain
More informationSYSTEM 25 SYSTEM 50 SYSTEM 63 SYSTEM 75 PP SYSTEM 100 ALSIDENT SYSTEM 75. Chemical Resistant (CR) Product Information
ALSIDENT SYSTEM 75 Chemical Resistant (CR) Product Information System 75 Chemical Resistant (CR) General Information Product Specification Product Description System 75 Chemical Resistant (CR) Alsident
More information200-SERIES EXTRACTION
FP 200-SERIES EXTRACTION / filter / POLLUTION CONTROL // technology www.tbh.eu FP 200-SERIES PEOPLE / ENVIRONMENT / MACHINERY // TRIPLE PROTECTION 2 FP 200-SERIES APPLICATION The FP 2 and FP 23 systems
More informationExhaust rail system 920 for stationary vehicles
Easy to handle systems for all types of workshops. Consists of a basic rail system which is completed with an exhaust extraction kit. Very high extraction efficiency. One extraction unit can serve several
More informationOperating instructions
Operating instructions (Translation of the original operating instructions) TEKA Caremaster Wall Assembly, SF-W 1, SF-W 2 TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach
More informationA X I A L A N D C E N T R I F U G A L F A N S A N D B L O W E R S F O R A L L I N D U S T R I E S
A X I A L A N D C E N T R I F U G A L F A N S A N D B L O W E R S F O R A L L I N D U S T R I E S Australia s leading fan company PRODUCT OVERVIEW COMMERCIAL INDUSTRIAL POWER & ENERGY MINING FOOD PROCESSING
More informationAFA TS GmbH - Werner von Siemens Str.3 - D Grafenberg Copyright 2009 Tel.: +49(0) Fax: +49(0)
AFA TS GmbH - Werner von Siemens Str.3 - D-72661 Grafenberg Copyright 2009 Tel.: +49(0)7123-97382-0 - Fax: +49(0)7123-97382-90 - E-Mail: mail@afa-ts.de Page 1-15 www.afa-ts.com Exhaust Extraction Systems
More informationFume Arms. Diversified Air Systems, Inc. Superior technology generating substantial operating savings. No internal adjustment
Diversified Air Systems, Inc. Fume Arms No internal adjustment Smooth tubes, low static pressure Air volume damper included Self-locking joints 2 grab handles for arm positioning Hood diverter increases
More informationNSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL
APPLICATION OF DUST CONTROL EQUIPMENT: CAUTION - Warning Improper operation of dust control system may contribute to conditions in the work area or facility that could result in severe personal injury
More informationVORTICENT C E RANGE Centrifugal fans
NEW VORTICENT C E RANGE Centrifugal fans Suitable for domestic, commercial and industrial applications: kitchens, bathrooms, offices, laboratories, factories, shops, laundromats, models, restaurants, bars,
More informationTWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw
TWA 212-1102 S/K/P Incorporating R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw The complete solution to all your cooling needs TWA 212-1102 S/K/P Index
More information2007 /
Product Catalogue Produktkatalog Каталог продукции компании Catalogue des produits Termékkatalógus Catalog de produse Katalog výrobků Catálogo de productos Katalog produktów Catálogo de Produtos Productcatalogus
More informationFlexPAK 800 DX. The leading extraction solution. Always the right capacity.
The leading extraction solution. Always the right capacity. The FlexPAK DX high vacuum unit represents the foremost solution on the market. The unit is designed for the extraction of welding fumes, grinding
More informationAffordable portable filtration unit
AQC source capture equipment Affordable portable filtration unit 750 to 800 CFM at the hood High efficiency cartridge Ideal for welding applications MAXAIR 6 X 10 fume arm included Filter pressure status
More informationMachines from the MULTIMATIC series are used all over the world. They are distinguished by their wide range of possibilities for use, high weight
44 Dough Dividing & Moulding Machine Machines from the MULTIMATIC series are used all over the world. They are distinguished by their wide range of possibilities for use, high weight precision, solid design,
More informationTECHNICAL MANUAL SOFFIO Ducted units
TECHNICAL MANUAL SOFFIO Ducted units Page 1 INDEX 1-INTRODUCTION... 4 2-OPERATING LIMITS... 4 3- KEY TO READING CODES... 5 4-TECHNICAL SPECS... 6 5-TECHNICAL DATA (AC motors)... 7 5.1-Unit 2 pipes with
More informationLightweight back pack vacuum cleaner designed for operator comfort, reducing fatigue. Effortless cleaning in noise sensitive areas
There are many things that should be present in a good backpack vacuum cleaner. It should be light in weight, with even weight distribution, and the noise level must be as low as possible.the battery version
More informationTW Electric hot-air automatic welding machine. Four wheel drive and belt system assures wrinkle free welding
TW 5000 Electric hot-air automatic welding machine Four wheel drive and belt system assures wrinkle free welding Adjustable front wheels for easy operation at different angles Powerful motor and efficient
More informationCODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S
REC PRO 9S High efficiency Heat Recovery Units Non residential applications EFFICIENCY 9% Comply with ErP Directive 125/29/CE and EU Regulation 1253/214. Classification: Non Residential Ventilation Unit
More informationMistral LC-MS Evolution Specification
Mistral LC-MS Evolution Specification Flow Rate: Outlet Pressure: Purity : Power Consumption : Circuit Breaker: Pressure accuracy : Microprocessor controlled display : Operating conditions : temperature
More informationQUOTATION BLADE 7 LX. Product code GEAL6S2BAA
1 of 10 Mattei rotary vane compressors are the result of 90 years of investments in research and development to improve performance and lessen the impact on the environment. Designed for industrial continuous
More informationCBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts
LOW PRESSURE CENTRIFUGAL FANS Series Range of double inlet direct driven low pressure centrifugal fans manufactured from galvanised sheet steel. All the models are fitted with forward curved centrifugal
More informationTECHNICAL DESCRIPTION Rescue Rod s AIR DISPLACEMENT UNIT MODEL MEGAVAC LOADER 8000 EVO Wet & dry vacuum
PRESSURE/VACUUM TANK - Volume : approx.13.400 litres, incl. the filter room. - Diameter : Ø 1.900 mm. - Material : stainless steel AISI 304 grade. - Suction connections : 6 block flange, provided with
More informationPump Station. Ama-Porter CK Pump Station. Type Series Booklet
Pump Station Ama-Porter CK Pump Station Type Series Booklet Legal information/copyright Type Series Booklet Ama-Porter CK Pump Station All rights reserved. The contents provided herein must neither be
More informationHPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM
1 Lmf Clima 216 FERRARO GROUP HPR Heat recovery units HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM from 7 to 23. m³/h Supporting structure in extruded aluminium profiles and curtain
More informationWeller Info No. 2. New in Weller Volume Extraction System WFE2ES
July 2007 www.cooperhandtools.com/weller New in 2007 Weller Volume Extraction System WFE2ES Weller Info No. 2 New for 2007: Weller Volume Fume Extraction System WFE2ES Our testing conclusively proves that
More informationTRIMMING TECH 180. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech180
IVD In vitro diagnostic-medical device CND code: W0202059016 - CIVAB code: TRIMMING TECH 180 General information Type of instrument: Aspirated hood for histology. Model: Trimming Tech 180. Code: Description:
More information