Ex PROFICIENCY TESTING PROGRAM

Size: px
Start display at page:

Download "Ex PROFICIENCY TESTING PROGRAM"

Transcription

1 Procedure Instruction i (1) Contents 1. General performance Procedure Functional test of Test Box "i" Calibration Contact resistance according to IEC : Data acquisition and data transmission Recording of the Test Results Documentation of the test setup PTB Working Group 3.54 Ex Proficiency Testing Team Version 1

2 1. General performance In this test round, the ignition probabilities are determined for each of the 12 circuits of Test Box "i" by means of a spark test apparatus in accordance with IEC :2007 Annex B. For this purpose, an explosive test mixture of group IIC, Table 7 (IEC :2007), consisting of 21% ± 2 % hydrogen mixed in air with the safety factor 1.0, has to be used for all tests/calibrations. The circuits of Test Box "i" are be connected to the spark test apparatus one after the other (Figure 1). Figure 1: Diagrammatic sketch of the test setup PTB Working Group 3.54 Ex Proficiency Testing Team Version 1 Page 1 of 10

3 2. Procedure The complete test procedure and the individual test steps are shown in the program flowchart and described in the associated table (Figure 2). Before the test to determine the ignition probability for the 12 circuits the number of revolutions and the contact resistance (see section 2.3) of used STA should be determined and entered into the template Test setup i (see section 3.2). Note: The ignition probability is understood as the ratio between the number of ignitons and the whole number of contacts. To determine the ignition probability for each of the 12 circuits 20 ignitions have to be realised. Thereby, the number of contacts (alternatively: the time or the revolutions) until ignition takes place must be recorded for each circuit. Note: The number of contacts means the number of wire movements across the cadmium disk or the number of revolutions of the wire holder multiplied by 4. The parameters and the dimensioning to be used to determine the ignition probabilities are predetermined in Test Box "i" as described in the "Roll-out" of the Proficiency Testing Program. After the circuit has been selected by rotary switch, the functional test is to be carried out in accordance with the Procedure Instruction, Section 2.1. Each time before and after the selected circuit is tested, the spark test apparatus has to be calibrated in accordance with IEC :2007 (Procedure Instruction, Section 2.2). For calibration, the number of contacts (alternatively: the time or the revolutions) until ignition takes place is recorded and entered into the template Test record i. The calibration circuit is installed in Test Box "i" too. The calibration currents are set with the potentiometer (see: Description of Test Sample i, Figure 7). After the calibration has been completed successfully, the ignition tests to determine the ignition probability of the selected circuit are carried out. The ignition probability is obtained from the average of the number of contacts (the time or the revolutions) until ignition takes place, whereby a total of 20 ignitions has to be achieved with the selected circuit. Additional Instructions: 1. After a total of 4000 contacts (1000 revolutions or 12.5 min at 80 min -1 ) in the calibration or in the ignition tests, the wires have to be replaced. PTB Working Group 3.54 Ex Proficiency Testing Team Version 1 Page 2 of 10

4 2. If during the ignition tests for one circuit (1000 revolutions or 12.5 min (at 80 min -1 )) no ignition has taken place after 4000 contacts, the tungsten wires have to be replaced and the above-mentioned calibration has to be carried out once again. After this new calibration, the ignition test has to be repeated with this circuit. After a total of 8000 contacts (2000 revolutions or 25 min (at 80 min -1 )) has taken place without any ignition occuring, the testing of this circuit has to be stopped. The break-off has to be recorded in the template Test record i. Figure 2: Flowchart of the test for each single circuit PTB Working Group 3.54 Ex Proficiency Testing Team Version 1 Page 3 of 10

5 Table 1: Explanations to the program flowchart Step Measure Remark 1 Selection of the circuit to be tested with the rotary switch 2 Functional test of Test Box "i" to check whether the selected circuit is damaged. 3 For every selected circuit, new tungsten wires have to be used for the test. 4 The calibration of the spark test apparatus must always be carried out before the selected circuit is tested(see Description of Test Sample i, section 2.2.2). The number of contacts until ignition takes place is to be entered in the template Test record i, Table 2. 5 Realisation of the ignition tests with the selected circuit(see Description of Test Sample i, section 2.2.1); Flush the spark test apparatus; Start the ignition test; Determination of the ignition probability (i.e. the average of 20 ignitions). 6 Maximum: 4000 contacts (1000 revolutions/12.5 min.) If within 4000 contacts, no ignition occurs, then: replace the wires, repeat the calibration and the ignition test. 7 The number of contacts (alternatively: the time/revolutions) until ignition takes place is to be entered in the template Test record i, Table 1. 8 After 20 ignitions the ignition test with the selected circuit ist finished 9 Calibration after testing(see Description of Test Sample i, section 2.2.2). The successful calibration after testing is also, at the same time, the calibration before testing of the next circuit (if there is no longer break between the tests i.e. less than 1 hour). The number of contacts is to be recorded in the Test record i, Table 2. see: Procedure Instruction, Section 2.1 see: Procedure Instruction, Section 2.2 See: Additional Instructions, No. 1 See: Additional Instructions, No. 2 see: Section 2.2 PTB Working Group 3.54 Ex Proficiency Testing Team Version 1 Page 4 of 10

6 2.1 Functional test of Test Box "i" The functional test has to be carried out by the participant for each circuit under test. The electrical values have to be in compliance with Table 2. All values have to meet the listed specifications. In the functional test, the installed voltage and the current of the respective circuit are to be measured and entered into the template Test record i. After both values in Table 2 have been achieved, the circuit may be applied in further measurements. Table 2: Measured voltages and currents for the circuits in Test Box "i" Circuits Installed Installed nominal voltage/v nominal current/ma Circuit 1 24 ± ± 5% Circuit 2 48 ± ± 5% Circuit 3 24 ± ± 5% Circuit 4 24 ± ± 5% Circuit 5 24 ± ± 5 % Circuit 6 24 ± ± 5% Circuit 7 24 ± ± 5% Circuit 8 22 ± ± 5% Circuit 9 22 ± ± 5 % Circuit ± ± 5% Circuit ± ± 5% Circuit ± ± 5% PTB Working Group 3.54 Ex Proficiency Testing Team Version 1 Page 5 of 10

7 2.2 Calibration The sensitivity of the spark test apparatus has to be checked before and after the testing with the calibration circuit. The calibration is carried out with the calibration circuit installed in Test Box "i". By means of potentiometer setting the current shall be reduced step by step. The sensitivity can be regarded as sufficient if an ignition occurs within 1760 contacts of the wire holder (alternatively: 440 revolutions or 5.5 min. (at 80 min -1 )) and with positive polarity. Regarding the flowchart of the calibration before and after the testing, see the diagram below and the associated table. The calibration starts at 35 ma. Then, the current is to reduce step by step by 1 ma down to a value of 30 ma. Entern the calibration results into the template Test record i, Table 2. The sensitivity of the spark test apparatus is sufficient if an ignition occurs within the above-mentioned contacts/revolutions of at least 30 ma. Additional instruction for the calibration: Step 1: If the sensitivity does not comply with the determined sensitivity, the following measures have to be taken: a) the composition of the explosive test mixture has to be checked; b) insertion of new tungsten wires; c) the spark test apparatus(sta) must be connected with a circuit of 95 mh/24 V/100 ma, and run the STA with the contacts in air for a duration of at least revolutions (about 250 min) of the electrode holder Step 2: After this, the calibration has to be repeated in accordance with the flowchart. The calibration has to be recorded in the template Test record i Step 3: If the current limit is measured only at 31 ma - 33 ma, the number of the contacts be recorded in the template Test record i. If the sensitivity of the spark test apparatus is not yet sufficient at 33 ma, please contact PTB. PTB Working Group 3.54 Ex Proficiency Testing Team Version 1 Page 6 of 10

8 Figure 3: Flowchart of the calibration Table 3: Explanations to the calibration flowchart Step Measure Remark 1 The calibration starts at 35 ma by potentiometer setting. see: Test Sample i, Section Maximum: 1760 contacts (440 revolutions/5.5 min.) If within 1760 contacts no ignition takes place, see: Additional Instruction for the Calibration then the measures listed under "Step 1" of the Additional Instruction for the Calibration have to be taken. 3 The number of contacts until ignition takes place is to be entered into the template Test record i, Table 2. 4 The sensitivity is sufficient if an ignition occurs at at least 30 ma. 5 The current is reduced step by step by 1 ma down to 30 ma. PTB Working Group 3.54 Ex Proficiency Testing Team Version 1 Page 7 of 10

9 2.3 Contact resistance according to IEC :2007 Because of reliability the contact resistance of the spark test apparatus is measured at 4 different contact positions, with the contacts closed, at a direct current of 1A, by using the following measurement setup: Figure 4: Measurement setup for the determination of the contact resistance The detected contact resistances should be recorded in the document Test setup i, Table 1. PTB Working Group 3.54 Ex Proficiency Testing Team Version 1 Page 8 of 10

10 3. Data acquisition and data transmission The templates for all the data, information and documentation to be collected are made available electronically via the Internet platform. Web address: Menu items: Participants area Test Round i Procedure Additional Instructions: 1. The transmitted data must be original data. 2. The information documentation Test setup i and the template Test record i should be filled in completely and uploaded to PTB Ex PTP Homepage in the section Participants area Result upload. No further action is required. 3. To understand easier which way the documentation should be drawn up, a sample documentation is included in "Procedure Instruction", with fictitious values. 3.1 Recording of the Test Results The test results of each circuit in Test Box "i" have to be entered into the template Test record i. For each circuit, the following data have to be entered into the template Test record i: Number of contacts until ignition occurred (for each ignition) Number of contacts until ignition occurred during the calibration; Voltage and current values of the circuit during the functional test. At the end of the test round, the template Test record i has to be uploaded at least 12 times for 12 circuits which should be transmitted to PTB. PTB Working Group 3.54 Ex Proficiency Testing Team Version 1 Page 9 of 10

11 3.2 Documentation of the test setup For a better understanding and for an analysis of the measurement results, additional information on the test setup should be provided. For the documentation of the test setup, the document Test setup i should be downloaded from the PTB Ex PTP Homepage. The following data should be entered into the documentation: a verbal description of the explosive test mixture preparation; one or two photos, showing the condition of the cadmium disk used (1 photo showing the whole disk and 1 close-up view); one photo of the spark test apparatus; one photo of the device for the explosive test mixture preparation; Protocol for the determination of the contact resistance. Please ensure that the whole setup is visible at the photo. The completed documents can be uploaded on the PTB Ex PTP Homepage and are transmitted to PTB. PTB Working Group 3.54 Ex Proficiency Testing Team Version 1 Page 10 of 10

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity Certificate No.: IECEx TUN 04.0006X Date of Issue: 2012-06-12 Issue No.: 3 Page 2 of 4 Manufacturer: FAFNIR GmbH Bahrenfelder Straße 19 22765 Hamburg Germany Manufacturing

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity Certificate No.: IECEx TUN 04.0006X Date of Issue: 2014-04-01 Issue No.: 4 Page 2 of 4 Manufacturer: FAFNIR GmbH Bahrenfelder Straße 19 22765 Hamburg Additional Manufacturing

More information

BAYLAN AUTOMATED TEST BENCH

BAYLAN AUTOMATED TEST BENCH BAYLAN AUTOMATED TEST BENCH At this test bench, the electromagnetic flow meters are used with the measurement method. Calibrations of flowmeters are made with the help of the water collection tank and

More information

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Sheet 1 of 5 Order Number Serial Number PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY Issue Date Level B 27/05/1999 Initial issue. Summary of changes Due to RMS continuous product improvement policy

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-1 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Datasheet / Product specification Model: Solar AAA

Datasheet / Product specification Model: Solar AAA 1. Product drawing D1 = 10.5 mm d1 = 4.8mm±0.2 mm H1 = 44.5 mm 2. Scope: This specification is applicable to rechargeable NiMH battery, HR03 distributed under brandname RAVER. 3. Law & Regulation Compliances:

More information

PTB Ex Proficiency Testing Program (PTB Ex PTP) Interlaboratory comparisons in explosion protection

PTB Ex Proficiency Testing Program (PTB Ex PTP) Interlaboratory comparisons in explosion protection ExTAG PTB Ex Proficiency Testing Program (PTB Ex PTP) Interlaboratory comparisons in explosion protection Dr Uwe Klausmeyer Convenor of ExTAG WG 10 Proficiency Testing Introduction / Importance Principles

More information

IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg

IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg REPORT IB-07-8-003 about the experimental testing of enclosed-break devices Thermostat type 077Bxxxx/L

More information

11 Control Panels, Distribution Panels and Components

11 Control Panels, Distribution Panels and Components Control Panels, Distribution Panels and Components Motor Switches Explosion protection to CENELEC IEC For use in Zone and Zone Isolator Motor switching capacity Rated working voltage up to Rated working

More information

Nickel Cadmium and Nickel Hydride Battery Charging Applications Using the HT48R062

Nickel Cadmium and Nickel Hydride Battery Charging Applications Using the HT48R062 ickel Cadmium and ickel Hydride Battery Charging Applications Using the HT48R062 ickel Cadmium and ickel Hydride Battery Charging Applications Using the HT48R062 D/: HA0126E Introduction This application

More information

PROGRAMMING MANUAL ZeelProg PDCI-20V

PROGRAMMING MANUAL ZeelProg PDCI-20V www.zeeltronic.com info@zeeltronic.com updated 21.11.2011 application version: 00.270711 PROGRAMMING MANUAL ZeelProg PDCI-20V Supported control units: PDCI-20V ZeelProg is PC application for programming

More information

This specification is applicable to the Nickel -Metal Hydride rechargeable batteries for type H320BC Model : H320BC

This specification is applicable to the Nickel -Metal Hydride rechargeable batteries for type H320BC Model : H320BC Document No:H320BC Page 1 of 7 1 Scope This specification is applicable to the Nickel -Metal Hydride rechargeable batteries for type H320BC Model : H320BC 2 Technical Parameters Items Units Parameters

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx UL 13.0077U issue No.:1

More information

EG DYNAMIC user manual

EG DYNAMIC user manual Timing Advance Processor EG DYNAMIC user manual ver. 1.1.0 dated 2012-10-01 This instruction can be also downloaded from: http://www.europegas.pl/en/technical-support/service-manuals Latest software version

More information

Fundamentals of Small Gas Engines

Fundamentals of Small Gas Engines Fundamentals of Small Gas Engines Objectives: Describe the four-stroke cycle engine operation and explain the purpose of each stroke Explain the concept of valve timing Describe two-stroke engine operation

More information

Model TUR-200D Turbine Flowmeter

Model TUR-200D Turbine Flowmeter General Specifications Model TUR-200D Turbine Flowmeter Liquid flows through the turbine housing causing an internal rotor to spin. As the rotor spins, an electrical signal is generated in the pickup coil.

More information

Gobius 1, Level Switch for Water, Fluid & Fuel Tanks

Gobius 1, Level Switch for Water, Fluid & Fuel Tanks Document release 1.0, September 2013 Gobius 1, Level Switch for Water, Fluid & Fuel Tanks Installation Guide Before you begin 1. Please make sure that no part is missing. (1 sensor, 1 panel, 1 control

More information

RVP-R- VAV controller. In explosion-proof version

RVP-R- VAV controller. In explosion-proof version VAV controller In explosion-proof version RVP-R- SMAY LLC / 29 Ciep³ownicza St. / 31-587 Cracow / Poland tel. +48 12 378 18 00 / fax. +48 12 378 18 88 / e-mail: info@smay.eu Intended use VAV control units

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Status:

More information

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 DL 0 Battery Powered for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless

More information

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories Selection and Application Associated s T 8355 EN ff. Edition January 2010 Information Sheet T 8350 EN Positioners,

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

Explosion Characteristics Measurement of Combustible Dusts

Explosion Characteristics Measurement of Combustible Dusts Explosion Characteristics Measurement of Combustible Dusts Industrial Explosion Protection Institute, Northeastern University Apr. 18, 2012 Table of contents 1 INTRODUCTION... 1 2 MAXIMUM EXPLOSION PRESSURE

More information

NO PART OF THIS DOCUMENT MAY BE REPRODUCED WITHOUT PRIOR AGREEMENT AND WRITTEN PERMISSION OF FORD PERFORMANCE PARTS.

NO PART OF THIS DOCUMENT MAY BE REPRODUCED WITHOUT PRIOR AGREEMENT AND WRITTEN PERMISSION OF FORD PERFORMANCE PARTS. Table of Contents Table of Contents... 1 Getting Started... 2 ProCal Flash Tool... 2 Verify Package Contents... 2 Getting to Know the ProCal 3 Software... 3 Prepare Vehicle for Flashing... 7 Download Calibration

More information

Instruction of connection and programming of the VECTOR controller

Instruction of connection and programming of the VECTOR controller Instruction of connection and programming of the VECTOR controller 1. Connection of wiring 1.1.VECTOR Connection diagram Fig. 1 VECTOR Diagram of connection to the vehicle wiring. 1.2.Connection of wiring

More information

Livewire TS User Guide

Livewire TS User Guide Livewire TS User Guide Introduction: - This guide will provide a brief overview of how to use the Livewire TS device. Please be sure you have the Livewire TS with the vehicle before continuing. Loading

More information

Petroleum industries are dealing with different hazardous materials starting from storing, processing and distributing the petroleum products These he

Petroleum industries are dealing with different hazardous materials starting from storing, processing and distributing the petroleum products These he FIRE SAFETY OF PETROLEUM INDUSTRIES By- Debapriya Biswas Additional Director General West Bengal Fire & Emergency Services Petroleum industries are dealing with different hazardous materials starting from

More information

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo Explosion-proof Solenoids II 2 G / II 2 D EEx dm IIC T4, T5, T6 Catalogue Maximum photo ATEX Explosionproof solenoids with flameproof enclosure/encapsulation "dm" According to ATEX directive 94/9/EC and

More information

Electrostatic Induction and the Faraday Ice Pail

Electrostatic Induction and the Faraday Ice Pail Electrostatic Induction and the Faraday Ice Pail Adapted from 8.02T Fall 2001 writeup by Peter Fisher and Jason Cahoon February 13, 2004 1 Introduction When a positively charged object like a glass rod

More information

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

Product Overview. Product Identification. Amps One CT Two CTs Three CTs AH06 (optional mounting bracket for small, medium, and large CTs) DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Gobius 1, Level Switch for Water, Fuel and Fluid Tanks, new version 5.0. Installation Guide. Before you begin

Gobius 1, Level Switch for Water, Fuel and Fluid Tanks, new version 5.0. Installation Guide. Before you begin Document release, 5.12, July 2017 Gobius 1, Level Switch for Water, Fuel and Fluid Tanks, new version 5.0 Installation Guide Before you begin 1. Please make sure that no part is missing. 1 sensor, 1 panel,

More information

Metallic materials Rockwell hardness test. Part 2: Verification and calibration of testing machines and indenters

Metallic materials Rockwell hardness test. Part 2: Verification and calibration of testing machines and indenters Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 6508-2 Third edition 2015-03-01 Metallic materials Rockwell hardness test Part 2: Verification and calibration of testing machines and indenters

More information

Series 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability

Series 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability Series 60 New Smart Positioner Compact design Convenient & powerful function Enhanced reliability J Flow Controls, LLC 14 De Camp Cincinnati, OH 45216 Phone: 513-731-2900 Fax 513-731-6939 www.jflowcontrols.com

More information

Gobius 4 for Waste Holding Tanks, new version 5.0

Gobius 4 for Waste Holding Tanks, new version 5.0 Document release 5.12, July 2017 Gobius 4 for Waste Holding Tanks, new version 5.0 Installation Guide Before you begin 1. Please make sure that no part is missing. 3 sensors, 1 panel, 1 control unit, 1

More information

Electronic Limit Switch Type

Electronic Limit Switch Type Electronic Limit Switch Type 3738-20 with optional solenoid valve for on/off rotary actuators Application Electronic limit switch for on/off applications to indicate the end position of rotary actuators.

More information

Pressure transmitter JUMO dtrans p02

Pressure transmitter JUMO dtrans p02 JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500 NANOPAC-300 & 500 Power Supply Instruction manual NANOPAC-300 & NANOPAC-500 Version 01C Feb 5th, 2014 1 Packing list NANOPAC-300 or 500-1x NANOPAC-300 Power Supply or NANOPAC-500-1x Power Cord - 1x Instruction

More information

Options guide. Electromagnetic flowmeters. M9xx

Options guide. Electromagnetic flowmeters. M9xx Options guide Electromagnetic flowmeters M9xx Ordering codes Model Description M 910 -V0 0 0 0 DN50 PN16 Example Sensor M Basic Ex Ex certified (remote version only) Transmitter 910E Economic version 910

More information

V200 Series Positioners

V200 Series Positioners V200 Series Positioners In a single compact and rugged housing The V200 positioner incorporates the flexibility of converting from a pneumatic unit to several versions of an electropneumatic unit, and

More information

Silver Oxide Button Cell 397. The specification is applicable to the Silver Oxide Button Cell 397 supplied by CHUNG PAK BATTERY WORKS LTD. -0.

Silver Oxide Button Cell 397. The specification is applicable to the Silver Oxide Button Cell 397 supplied by CHUNG PAK BATTERY WORKS LTD. -0. 1Scope CHUNG PAK The specification is applicable to the supplied by CHUNG PAK BATTERY WORKS LTD. 2Kind of Products Specified Name (Designation) 397 IEC Designation SR59 3Technical Specification 3.1 Dimension

More information

NI-MH LOW-SELF DISCHARGE READY TO USE

NI-MH LOW-SELF DISCHARGE READY TO USE Product Datasheet NI-MH LOW-SELF DISCHARGE READY TO USE RS Article No.: 9053781 1. Scope of Application: Type Nominal Voltage 1.2V/cell Capacity Typical 2000 mah/0.2 CmA@20 Minimum 1900 mah/0.2 CmA@20

More information

OMNICOMM IS THE DEVELOPER AND MANUFACTURER OF ALL THE COMPANY S BRAND PRODUCT LINE.

OMNICOMM IS THE DEVELOPER AND MANUFACTURER OF ALL THE COMPANY S BRAND PRODUCT LINE. OMNICOMM is international hi-tech industrial company, one of the leading developers and manufactures of fleet management and fuel monitoring systems for various fleet management needs. Omnicomm has one

More information

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 *

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 * SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 * PRODUCT: Polymer (Foam-Filled) Fuel Cells 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards

More information

Instruction Manual. Ex-Time 40 / 50

Instruction Manual. Ex-Time 40 / 50 Instruction Manual Ex-Time 40 / 50 Contents 1. Introduction 13 2. Safety Advice 13 3. Faults and Damage 13-14 4. Safety Regulations 14 5. Ex-Data 14-15 6. Technical Data 15-16 7. Use and Application /

More information

Using the Gratec Gasoline software

Using the Gratec Gasoline software Using the Gratec Gasoline software The Gratec Software is a sophisticated yet user friendly program in which configures the Gratec CNG or LPG system to perform with your vehicle. Software version 2.002

More information

CHAPTER 9 : TYPE II TEST ON SI ENGINES (VERIFYING CARBON MONOXIDE EMISSION AT IDLING)

CHAPTER 9 : TYPE II TEST ON SI ENGINES (VERIFYING CARBON MONOXIDE EMISSION AT IDLING) CHAPTER 9 : TYPE II TEST ON SI ENGINES (VERIFYING CARBON MONOXIDE EMISSION AT IDLING) 1 Scope : This Chapter describes the procedure for the TYPE II test for verifying carbon monoxide emission at idling

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS RTECK terminal boxes RTKB series IEC Ex EX010 TECHNICAL FILES CONTENTS: 1) Contents 2) General information 3) Safety information 4) Conformity to standards 5) Function 6) Technical

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Liquid Turbine Flow Meter OwnerÊs Manual

Liquid Turbine Flow Meter OwnerÊs Manual Liquid Turbine Flow Meter OwnerÊs Manual Manual LWGY-G Rev.1.0 Content 1.0 GENERAL INFORMATION... 1 2.0 SPECIFICATIONS... 2 3.0 OPERATION CONDITIONS... 3 4.0 CAUTIONS FOR INSTALLATION... 4 5.0 DIMENSION...

More information

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb sales@jumo.co.uk info@jumo.us Data Sheet 404385 Page 1/6 JUMO dtrans p02 Pressure transmitter II 1/2G Ex ia IIC T6 Ga/Gb General application The pressure transmitter Type JUMO dtrans p02 is used to measure

More information

SPREADER SYSTEM. Proportional three function. 1. Features and Specifications. User Manual 12 INPUTS 12 OUTPUTS CONNECTIVITY MAIN FEATURES

SPREADER SYSTEM. Proportional three function. 1. Features and Specifications. User Manual 12 INPUTS 12 OUTPUTS CONNECTIVITY MAIN FEATURES User Manual SPREADER SYSTEM Proportional three function 12 INPUTS 3 interrupt digital inputs. 3 digital inputs for engine control (alternator, accelerator, oil alarm). 1 digital input for tachometer (squared,

More information

When you finish the running, power off the receiver BEFORE turning off the transmitter.

When you finish the running, power off the receiver BEFORE turning off the transmitter. Thanks for purchasing Turnigy AQUASTAR ESC speed controllers. Turnigy AQUASTAR ESC are specifically developed to supply stable and strong power for r/c model boats beyond you expected. Please read the

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery MS5900 Users Manual Table of Contents Introduction Motor and Phase Rotation Indicator is a handheld, battery-operated instrument designed to detect the rotary field of three-phase systems and determine

More information

Description. Fieldbus Optimized Through Junction Boxes

Description. Fieldbus Optimized Through Junction Boxes Easy and safe connection for sensors, actuators and measuring instruments to the fieldbus - Foundation TM fieldbus, PROFIBUS-PA or HART Rugged assembly for industrial and hazardous areas Reduces wiring

More information

Product specification

Product specification Product specification Features Non-contacting displacement measurement based on the eddy-current principle System length: 5 m or 10 m with ATE approval Temperature range displacement sensor: -55 C +180

More information

INTERNATIONAL METAL ENGINEERING

INTERNATIONAL METAL ENGINEERING INDICATING TEMPERATURE TRANSMITTER WITH HART 8080HT UNIVERSAL SETTINGS WITH HART PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE TECHNOLOGY, 4 TO 20mA ANALOG OUTPUT HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE

More information

Fluke 750P Series Pressure Modules

Fluke 750P Series Pressure Modules TECHNICAL DATA Fluke 750P Series Pressure Modules Precision pressure measurement for 750 and 720 series calibrators The 750P Series Pressure Modules are the ideal pressure modules to enable gage, differential

More information

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS Solenoid coils Solenoid coils Product range overview Version Type For valve series Page/ Internet MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS F solenoid coil MSF VACF 3 N solenoid coil VACN-N 6 N

More information

Owners Manual for TPMS plus GPS

Owners Manual for TPMS plus GPS To ensure correct operation and service please read these instructions before installing and operating the TPMS feature of the TPMS/GPS unit. Owners Manual for TPMS plus GPS TABLE OF CONTENTS TIRE PRESSURE

More information

SPECIFICATION FOR VH F CONTENTS

SPECIFICATION FOR VH F CONTENTS CONTENTS 1/ SCOPE 2/ GENERAL ELECTRICAL CHARACTERISTICS 3/ GENERAL MECHANICAL CELL SPECIFICATION 4/ CAPACITY 5/ CHARGE RECOMMENDATIONS 6/ CYCLE LIFE 7/ CELL AND BATTERY MANAGEMENT 8/ SPECIFICATION APPROVALS

More information

LED Explosion proof Exit light

LED Explosion proof Exit light Polaris Series LED Explosion proof Exit light Ex Mark:Ex ib mb IIC T6 Gb KHJ-LED Explosion Proof Lighting 1 INTRODUCTION Features and benefits 1.Robust light alloy housing 2.Power saving LED technology;

More information

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

SmarTire TPMS Maintenance Hand Tool. Revision User Manual SmarTire TPMS Maintenance Hand Tool Revision 1.03 User Manual Page 2 Table of Contents FCC Compliance Label...4 User Interface Illustration...4 Introduction...5 Testing Tire Sensors...5 Main Menu...6 Main

More information

AVL PLU 131U FLOW METER

AVL PLU 131U FLOW METER CONSUMPTION MEASUREMENT TECHNOLOGIES AVL PLU 131U FLOW METER AVL PLU131 UREA FLOW MEASUREMENT SENSORS Function Summary The AVL PLU 131U-020 Flow Sensor has been designed for transient flow rate measurement

More information

RS Stock number

RS Stock number RS Stock number 617-0773 Description: For general purpose applications No memory effect Note: All batteries are supplied with only a residual charge and should be charged at the continuous charge rate

More information

Operating instructions

Operating instructions Operating instructions Digital tank contents indicator DTA 10 DTA 10 DTA 10 0 4.0 m fuel oil 0 3.5 m water Read instructions before using device! Observe all safety information! Keep instructions for future

More information

Chem(Bio) Week 10 Bomb Calorimetry of Biodiesel

Chem(Bio) Week 10 Bomb Calorimetry of Biodiesel Lab Overview: Water/ check status plants (at some point) Biodiesel Workup (may not be necessary) Bomb Calorimetry of biodiesel (calorimeter calibration will be necessary) IR spectroscopy of biodiesel (possibly

More information

OSU Rate of Heat Release Apparatus

OSU Rate of Heat Release Apparatus OSU Rate of Heat Release Apparatus THE BENCHMARK IN FIRE TESTING OSU Rate of Heat Release Apparatus FAR 25.853 (a-1), FAA Fire Test Handbook Chapter 5, ASTM E 906 Configuration A Standard Test Method for

More information

RESOLUTION MEPC.205(62) Adopted on 15 July GUIDELINES AND SPECIFICATIONS FOR ADD-ON EQUIPMENT FOR UPGRADING RESOLUTION

RESOLUTION MEPC.205(62) Adopted on 15 July GUIDELINES AND SPECIFICATIONS FOR ADD-ON EQUIPMENT FOR UPGRADING RESOLUTION MEPC.60(33)-COMPLIANT OIL FILTERING EQUIPMENT MEPC.60(33)-COMPLIANT OIL FILTERING EQUIPMENT MEPC 62/24/Add.1 Annex 24, page 1 ANNEX 24 RESOLUTION MEPC.205(62) 2011 GUIDELINES AND SPECIFICATIONS FOR ADD-ON

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

Lithium Battery UN38.3 Test Report

Lithium Battery UN38.3 Test Report Lithium Battery UN38.3 Test Report Prepared For : Samples Name: Model : Prepared By : Report No.: Shenzhen Haomingshe Electronic Technology Co., Ltd. 2F, Building E, Huachuangda Industrial Park, Hangcheng

More information

MODEL NO:NI-MH 4 AA V

MODEL NO:NI-MH 4 AA V (Model No)NI-MH 4 AA1800 4.8V (DATE):26/04/2017 VIGOR POWER NIMH BATTERIES SPECIFICATIONS MODEL NO:NI-MH 4 AA1800 4.8V (PREPARED BY): (CHECKED BY ): (APPROVED BY): DATE: DATE: DATE: (Type):NI-MH 4 AA1800

More information

Lithium Battery UN38.3 Test Report

Lithium Battery UN38.3 Test Report Lithium Battery UN38.3 Test Report Prepared For : Samples Name: Model : Prepared By : Report No.: Allfine Lithium Energy (Hefei) Co., Ltd. Building 12, Mechatronics Industrial Park, Fengle Road, Hefei

More information

Product specification

Product specification Product specification 4 mm Measuring Range Features Non-contacting displacement measurement based on the eddy-current principle System length: 5 m or 10 m with ATE approval Temperature range displacement

More information

ISO 3679 INTERNATIONAL STANDARD. Determination of flash point Rapid equilibrium closed cup method

ISO 3679 INTERNATIONAL STANDARD. Determination of flash point Rapid equilibrium closed cup method INTERNATIONAL STANDARD ISO 3679 Third edition 2004-04-01 Determination of flash point Rapid equilibrium closed cup method Détermination du point d'éclair Méthode rapide à l'équilibre en vase clos Reference

More information

Technical Data. Dimensions

Technical Data. Dimensions Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush

More information

CurveMaker HD v1.0 2Ki Programmable Ignition programming software

CurveMaker HD v1.0 2Ki Programmable Ignition programming software Contents CurveMaker HD v1.0 2Ki Programmable Ignition programming software Dynatek 164 S. Valencia St. Glendora, CA 91741 phone (626)963-1669 fax (626)963-7399 page 1) Installation 1 2) Overview 1 3) Programming

More information

Manganese Dioxide Lithium Battery CR1216

Manganese Dioxide Lithium Battery CR1216 Model No:CR1216 Page 1 of 8 1 Scope This specification is applicable to the Vinnic brand Coin Type supplied by CHUNG PAK BATTERY WORKS LTD. 2 Technology Parameters 2.1 Model No.: CR1216 2.2 Nominal Voltage:

More information

burners with or without fan. It conforms to EN C). APPROVAL EU type test approval as per EU Gas Appliance Directive.

burners with or without fan. It conforms to EN C). APPROVAL EU type test approval as per EU Gas Appliance Directive. LAST UPDATE 29/08/12 INSTALLATION INSTRUCTIONS v. 3 UNIT SPECIFICATIONS Main Gas Valve, Pilot Gas Valve Ionisation, Ignition and Flame Monitoring with Common Electrode or Remote Sensor Integrated Cyclic

More information

Specification Approval Sheet

Specification Approval Sheet Specification Approval Sheet Name: Nickel-Metal Hydride Battery Model: 10003 SPEC: 8.4V (9V size) 200mAh LSD Cell File Number:/ Project: / Approved By Checkup Make Andy / Haixia Bi 2016-7-13 / 2016-7-13

More information

Operating Instructions Overcurrent Protection - Tester

Operating Instructions Overcurrent Protection - Tester Operating Instructions Overcurrent Protection - Tester WWW.LECOM.CN CONTENTS Table of contents 1. ORDER REFERENCE...2 1.1. Standard set...2 1.2. Options...3 2. INTRODUCTION...4 2.1. General description...4

More information

AM - parking assistance systems Park with confidence

AM - parking assistance systems Park with confidence [Digitare qui] AM - parking assistance systems Park with confidence Vodafone Power to you All makes and vehicle types have hazardous reversing blind areas. Reduced visibility behind and in front of the

More information

Minimum Ignition Energy Test Apparatus for Dust Cloud

Minimum Ignition Energy Test Apparatus for Dust Cloud Minimum Ignition Energy Test Apparatus for Dust Cloud Industrial Explosion Protection Institute Northeastern University, P. R. China Jan. 3, 2010 1 Introduction Minimum ignition energy is the lowest energy

More information

SFI SPECIFICATION 34.1 EFFECTIVE: January 13, 2017*

SFI SPECIFICATION 34.1 EFFECTIVE: January 13, 2017* SFI SPECIFICATION 34.1 EFFECTIVE: January 13, 2017* PRODUCT: Screw-Type Superchargers 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards for evaluating

More information

Programmable Safety Systems for Burner Management on Gas Turbines.

Programmable Safety Systems for Burner Management on Gas Turbines. Programmable Safety Systems for Burner Management on Gas Turbines. As the demand for energy throughout Australia increases the demand for alternative sources is increasing accordingly. The use of gas turbine

More information

KINAX SR 709 Transmitter for position feedback

KINAX SR 709 Transmitter for position feedback KINAX SR 709 Transmitter f position feedback Position transmitter with NAMUR valve fitting Application The position feedback transmitter KINAX SR 709 (Fig. 1 and 2) is used to measure and transmit linear

More information

ORIMAS Mass Flowmeter

ORIMAS Mass Flowmeter Typical Applications ORIMAS Mass Flowmeter The ORIMAS mass flow meters measure the mass flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical

More information

MANUAL D250SA SMARTPASS 120. Input Solar panel Earth Connection

MANUAL D250SA SMARTPASS 120. Input Solar panel Earth Connection MANUAL CONGRATULATIONS on the purchase of your new CTEK charger providing professional battery care. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the

More information

Lithium Battery UN38.3 Test Report

Lithium Battery UN38.3 Test Report Lithium Battery UN38.3 Test Report Prepared For : Samples Name: Shenzhen Pu Sheng Power Supply Technology Co., LTD. Rm501, 5F, Jinsheng Industrial Zone, No.109, HuDiPai, DaFu, GuanLan Town, LongHua New

More information

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal Certificate of Calibration We hereby certify that this product has been calibrated and found to be in accordance with the applicable SPECIFICATIONS and STANDARDS. Accuracies of the standard equipment used

More information

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87 SMART VALVE POSITIONER to ma + HART Digital Communication B87 DESCRIPTION The FY microprocessor based positioner provides fast and accurate positioning of diaphragm or cylinder actuators. The FY produces

More information

Jet Fuel Conductivity Analysers & Additive Management systems

Jet Fuel Conductivity Analysers & Additive Management systems Jet Fuel Conductivity Analysers & Additive Management systems ASTM D2624 IP 274 DEF STAN 91-91 ASTM D1655 Conductivity in Fuels Conductivity is a significant parameter for safe and economic handling of

More information

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Operating Instructions for Float Flow Meter / Monitor. Model: SWK Operating Instructions for Float Flow Meter / Monitor Model: SWK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 4 5. Operating Principle... 4 6. Use in Hazardous

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60884-1 Edition 3.1 2006-07 Edition 3:2002 consolidated with amendment 1:2006 Plugs and socket-outlets for household and similar purposes Part 1: General requirements IEC 2006

More information

first issue : last change : MSD Platinum 15 R number of pages : 12 LE 2166

first issue : last change : MSD Platinum 15 R number of pages : 12 LE 2166 first issue : 2011-02-07 S FOR MSD Platinum LAMP SYSTEMS last change : 2013-01-11. MSD Platinum 15 R 9281 916 05300 number of pages : 12 Philips Innovative Applications N.V. Specifications subject to change

More information

Digital Transformer Ratiometer

Digital Transformer Ratiometer Digital Transformer Ratiometer FEATURES Measures power transformers, VT/PTs, and current transformer CT turns ratios Direct turns ratio readings from 0.8000:1 to 8000.0:1 Tests performed by exciting the

More information

Attachment to Certificate IECEx PTB X

Attachment to Certificate IECEx PTB X Applicant: Electrical Apparatus: Pepperl + Fuchs GmbH Cuboidal inductive proximity sensors Types Fj, NJ, NB and NC The cuboidal inductive proximity sensors of types Fj, NJ, NB and NC are used to convert

More information

GS-AQ1000 VOC Indoor Air Quality Sensors

GS-AQ1000 VOC Indoor Air Quality Sensors Page 1 of 5 VOC ndoor Air Quality Sensors Features: Benefits: Multi-function sensor Fully configurable LCD Display Direct thermistor temperature options available High stability & reliability Long term

More information