UW5000 Series Ultrasonic Levelmeter
|
|
- Owen Stevenson
- 6 years ago
- Views:
Transcription
1 SOUNDM UW5 Series Ultrasonic Levelmeter GENERL UW5 Series is an ultrasonic noncontact level meter that can measure liquid, slurry and solid level continuously. UW5 can be used for wide range of application and measuring span with variety of sensors. The combination of the high efficiency sensors as well as state of the art signal treatment and evaluation based on years of experi ences ensures the measurement in a difficult condition, which used to be judged uncertain to measure by ultrasonic technology. UW5 offers either integral or remote sensors by application. Simple push button commissioning, C and/or DC power supply are available for both integral and remote type sensors. RS85 MODUS output is standard even for 2 wire system instruments that are suitable for remote commissioning and data acquisition by a PC with dedicated software. UW5 series is an ultimate level meter for the most applications in any industry. FETURES Non contact, Continuous level measurement in use of acoustic wave Suitable for liquids, slurries, powders, granulates and even rocks Selectable 2 wires loop power or C/DC power supply type Integral and remote type are selectable by mounting and measurement conditions High efficiency, high power sensors realizes up to 6 m range uiltin temperature sensor as standard for sound velocity compensation utomatic controlled threshold, false echo mapping are the standard features Relays are integrated to C/DC power type for pump control, overflow protection and elimination of empty pumping Outputs of level, distance, volume, difference of two sensors, average of measurement values PPLICTION RE Water/Waste water, Fluvial and gricultural water : Openchannel, Underdrain, Waterintake screen control, Pump station, Dam, River water, Chemical additives Steel, Stone crushing, Mining, Cement : Crusher, Hopper, Conveyer junction, Stacker/Reclaimer, Storage silo, Water treatment plant Power station : Coal bunker, Coal silo, ottom & Fly ash, Waterintake screen control, Water treatment plant Foods/nimal feeds : Flour, Wheat, Mice, Cereal, Grain, Morasses, Syrup, dditives, Water, Cacao, Paste, utter, Edible oil, Margarine Chemica/Plastics : Pellets silo, Powder silo, Chemicals Pulp and paper : Wood chips, White liquid, lack liquid, Chemicals, Water treatment plant Semiconductor industry : Pure water, Ultra pure water, Chemicals, Water treatment MESURING PRIIPLE Emission pulse Reflection pulse Inlet Output
2 SOUNDM Ultrasonic Levelmeter UW 5 Series SPCIFICTION Object Item Description Common Specification Measurement Purpose Measuring object Measuring principle Non contact continuous level measurement.vessel top mounting Liquid, Slurries, Powders, Granulates, Rocks coustic wave Pulse Echo Object Item Description Output items Level, Distance (Ullage), Volume, verage level, Difference level Common Electric Specification Output ccuracy Power supply nalogue output Relay output (Only C/DC type) Digital output Under reference condition C/DC type 2 wire loop powered Output signal Maximum load Numbers of relays Contact rating Specification /Protocol to 2m DC 75Ω : UW52, UWC52 (2 wire system) 27Ω : UW5, UWC5 (C/DC power supply) 2 relays (Integral sensor type, C/DC power supply) 5 relays (Remote converter type, C/DC power supply) SPDT Max..5, 2V C RS85 MODOUS / RTU Connection should be individual twisted pair (screened for longer distance) ±.25% of Max. range for each sensor 9 to 26V C 5/6 Hz,2 to 3 V DC 2 to 3 V DC (Max. ripple mv) Power consumption C/DC type 2 wire loop powered Max. V (C) Max. W (DC) Object Item Description Environmental/Process Specification Temperature Pressure Protection class Cable Length pproval Remote sensor Integral sensor/remote converter Process pressure Remote sensor/integral sensor Remote converter uiltin cable to remote sensor Remote sensor to remote converter Ex ia II T (2C, 7C) to 8 C to 8 C TM to 5kPa IP67 (IEC6529) IP65 (IEC6529) 6m (Standard), 5m, 3m, 5m (Option) Max.5m ( cores : 2 twisted pair individually/screed/communication) Integral sensor : UW525, 52,522, 523, 525, 526 Remote sensor : UWS55, 5, 52, 53, 55, 56 (Combination to UWC52) Object Range Category Short Range Middle Range Long Range Type UW5 5 UW5 UW5 2 UW5 3 UW5 5 UW5 6 Measuring Range 5m (Liquid) m (liquid) 2m (liquid) m (solid) 3m (liquid) 2m (solid) 5m (liquid/solid) 6m (liquid/solid) Frequency 5kHz 3kHz 2kHz 5kHz khz 5kHz Sensor specification (Integral sensor) locking Distance (From transmitter side) Min..3m Min..m Min..6m Min..8m Min..5m Min. 2.m eam ngle (With focalizer horn) 6 (With focalizer horn) (One side) 7.5 (Without focalizer horn) 6 (With focalizer horn) Resolution ±mm ±mm ody : PT 2 /ETFE ody : PT/PP 2 ody : PT/PP 2 Material Membrane (Gascontacting part): Flange, Focalizer horn : PP Flange, Focalizer horn : PP Membrane (Gascontacting part): Membrane (Gascontacting part): ETFE PTFE Polyolefine " flange (with focalizer horn) or " flange (with 2" screw without focalizer horn focalizer horn) " flange (with focalizer horn) Type UWS55 UWS5 UWS52 UWS53 UWS55 UWS56 Measuring 2m (liquid) 3m (liquid) 5m 6m Range 5m (Liquid) m (liquid) m (solid) 2m (solid) (liquid/solid) (liquid/solid) Frequency 5kHz 3kHz 2kHz 5kHz khz 5kHz (Remote sensor) locking Distance (From transmitter side) eam ngle (One side) Resolution Min..3m Min..m Min..6m Min..8m Min..5m Min. 2.m (With focalizer horn) 6 (With focalizer horn) 7.5 (Without focalizer horn) ±mm 6 (With focalizer horn) ±mm Material ody : PT 2 /ETFE Membrane (Gascontacting part): ETFE ody : PT/PP 2 Flange, Focalizer horn : PP Membrane (Gascontacting part): PTFE ody : PT/PP 2 Flange, Focalizer horn : PP Membrane (Gascontacting part): Polyolefine " flange (with focalizer horn) or 2" screw without focalizer horn " flange (with focalizer horn) " flange (with focalizer horn) " flange mounting with focalizer horn is recommended. 2 PT (Polybutylene terephthalate), PP () 2 TOKYO KEISO CO., LTD. TGEM6E
3 SOUNDM Ultrasonic Levelmeter UW 5 Series OUTLINE DRWING Remote Sensor 8. Sensor Type Flange equivalent to IS K or NSI Class5 Dimensions C uiltin cable G" UWS55 UWS5 UWS52 UWS53 UWS55 UWS56 mm/" mm/" mm/" 25mm/" 25mm/" 25mm/" C G2" or 2" NPT 53 UWS55, UWS5 UWS52, 53, 55, 56 Integral sensor pprox pprox 6 Cable entries M6 : 3 pieces cable gland is attached as the standard accessory suitable cable diameter 5 to mm. Sensor Type Flange equivalent to IS K or NSI Class 5 Dimensions C C pprox 3 53 pprox 5 UW55 UW5 UW52 UW53 UW55 UW56 mm/" mm/" mm/" 25mm/" 25mm/" 25mm/" G2" or 2" NPT UW55, UW5 UW52, 53, 55, 56 TGEM6E TOKYO KEISO CO., LTD. 3
4 SOUNDM Ultrasonic Levelmeter UW 5 Series Remote Converter Cable entries (at the bottom of housing) 6mm 2mm For wall mounting holes For screw fixing holes TERMINLS Integral sensor, C/DC supply (UW5) Sensor terminals Integral sensor, 2 wire system (UW52) Sensor terminals Shld MS SHLD 2m TEST L N Test CIN 2m DCIN Remote converter, C/DC supply (UWC5) Converter terminals Remote converter, 2 wire system (UWC52) Converter terminals RELY RELY2 RELY3 RELY RELY5 MS TEST SHLD SHLD NLOG TRNSDUCER MS DCIN CIN TRNSDUCER DCIN RED LK LUE WHIT Testin 2m MS DCIN CIN N L RED LK LUE WHIT 2m TOKYO KEISO CO., LTD. TGEM6E
5 SOUNDM Ultrasonic Levelmeter UW 5 Series CONNECTION DIGRM wires connection : C or DC Power supply & nalogue output Power supply C L N DC 2 wires system : DC power supply with nalogue output Power supply Load Max. 27Ω (Including line resistance) 2m 2m Load Max. 75Ω (Including line resistance) 2m UW/UWC 2m UW/UWC 3 wires connection : DC Power supply & nalogue output Connection of remote sensor Power supply DC RELY RELY2 RELY3 RELY RELY5 Load Max. 75Ω (Including line resistance) 2m 2m NLOG TRNSDUCER MS DCIN CIN UW/UWC 2m RED LK LUE WHITE Power supply Red lack Shield lue White 2m RED LK LUE WHITE Testin N L DC Load Max. 75Ω (Including line resistance) 2m Use 2 screened twisted pair cable with shield sheath. (Communication cable) Provide with a terminal box when cable is extended. UW/UWC Red lack lue White Shield Red lack lue White TGEM6E TOKYO KEISO CO., LTD. 5
6 SOUNDM Ultrasonic Levelmeter UW 5 Series TICE OF USE location Mount the sensor around /3 of the vessel radius from the vessel wall. Do not mount the sensor at the center of the vessel. In case of mounting to a horizontal cylindrical tank, mount the sensor offset / to /3 of radius from the center line. Do not mount the sensor at the center of the vessel Min 5 Min 5 Span /3R R Span /3 to /R R 2 location should be carefully selected where inlet material will not intrude into the sound robe. lso locate the sensor where no inner structure those reflects sound such as agitator blade, ladder or beam in the sound robe. In case of mounting to the tank with agitator, locate the mounting position in the center between tank wall and tip of the agitator blade. When the vessel wall is straight and smooth, it is able to mount the sensor close to the vessel wall where sound robe touching to the vessel wall. If the welding bead is rough and juts out, avoid the mounting position where the welding bead is in the sound robe or make the welding bead flat and smooth. Do not install the sensor at the center of the vessel. Do not install the sensor in the area where inflow of liquids and powders is within the sound robe. Do not mount close to any obstacle that reflects sound. Min 5 " " R Span Do not install level meter in the place where vibration is fierce. Install a shade in the place where direct sunlight hits. Center the sensor between tank wall and blade 6 TOKYO KEISO CO., LTD. TGEM6E
7 SOUNDM Ultrasonic Levelmeter UW 5 Series of the sensor Nozzle length Mount the sensors for both integral and remote sensor types using flange or screw. The mounting nozzle on the vessel shall have the length so that the sensor (vibrating membrane) or lower end of focalizer horn protrudes at least 5mm into the inside vessel. Mount the sensor that the end of the sensor or focalizer horn juts to the vessel minimum 5 mm. Min 5 2 locking distance UW5 sensors has its own blocking distance, where sensor is not able to measure the level. locking distance means the one from the transmitter side of a sensor. e sure that the highest measured level is below the blocking distance. Consider the blocking distance for the Installation of the sensor. Highest level should be below the blocking distance. locking Distance locking Distance Highest level 3 Mount the sensor Vertically for liquid measurement. In case of solid measurement, it might be effective for receiving reflection signal by inclining the sensor to the solid surface if the resting angle is steep and steady. Focalizer horn Use of focalizer horn is recommended for narrowing sound robe and effective signal detection. Especially it is recommended when using middle and long range sensor. The focalizer horn shall be used so that lower end of focalizer horn comes out of mounting nozzle. Without the focalizer horn, the blocking distance may be larger. of the remote converter For the mounting of the remote converter, select the location where temperature is within the temperature range and avoid vibration, electrical noise and dust as much as possible. Remote converter can be mounted on the wall or stanchion pipe (pipe adapter is required). Cautions on the sensor handling Fasten the sensor with your hands not using tool when screwing the sensor onto the nozzle. Excess force might damage the sensor. 2 Do not drop sensor on the floor or do not apply any mechanical shock. TGEM6E TOKYO KEISO CO., LTD. 7
8 SOUNDM Ultrasonic Levelmeter UW 5 Series SOUNDM Specification Code Integral 2 wire loop powered Type Short range for Liquids Standard sensor material for wetted part (Vibrating part Case, Membrane : ETFE) Specification Code UW52 S T 6 Integral 2 wire sensor for short range Range/ UW525 S 5 T 6 Max. 5m Liquids 5kHz Frequency UW52 S 3 T 6 Max. m Liquids 3kHz T 2 Thread mounting G2 male thread T N 2 Thread mounting 2"NPT male thread lways NSI Class 5 equivalent diameter and bolt holes IS K equivalent diameter and bolt holes mm/" ottom of sensor Without horn 2 With horn (only with flange) Without horn (Please use in case use of focaliser horn) Middle range for Liquids & Solids Standard sensor material (Vibrating part Case : /Membrane : PTFE) Specification Code Range/ Frequency UW52 UW522 UW523 S S S 2 5 T T T 5 Integral 2 wire sensor for middle range Max. 2m Liquids/m Solids 2kHz Max. 3m Liquids/2m Solids 5kHz lways 5 NSI Class 5 equivalent diameter and bolt holes IS K equivalent diameter and bolt holes mm/" for UW522 25mm/" for UW523 Sensor end For UW522 For UW523 Long range for Liquids & Solids Standard sensor material (Vibrating part Case : /Membrane : Polyolefine) Specification Code UW52 S S Integral 2 wire sensor for long range Range/ UW525 S S Max. 5m Liquids/Solids, khz Frequency UW526 S 5 S 5 Max. 6m Liquids/Solids, 5kHz lways NSI Class 5 equivalent diameter and bolt holes IS K equivalent diameter and bolt holes 25mm/" for UW525/UW526 Sensor end For UW525 5 For UW526 8 TOKYO KEISO CO., LTD. TGEM6E
9 SOUNDM Ultrasonic Levelmeter UW 5 Series Integral model C/DC powered Type with 2 relays output Short range for Liquids Standard sensor material for wetted part (Vibrating part Case, Membrane : ETFE) Specification Code UW5 S T 6 Integral C/DC supply sensor for short range Range/ UW55 S 5 T 6 Max. 5m Liquids, 5kHz Frequency UW5 S 3 T 6 Max. m Liquids 3kHz 2V DC Power supply U 9 to 26V C 5/6Hz T 2 Thread mounting G2 male thread T N 2 Thread mounting 2"NPT male thread lways None NSI Class 5 equivalent diameter and bolt holes IS K equivalent diameter and bolt holes 2 mm /" ottom of sensor Without horn With horn (only with flange) Without horn (Please use in case use of focaliser horn) Middle range for Liquids & Solids Standard sensor material (Vibrating part Case : /Membrane : PTFE) Specification Code UW5 S T Integral C/DC supply sensor for middle range Range/ UW52 S 2 T Max. 2m Liquids/m Solids 2kHz Frequency UW53 S 5 T 5 Max. 3m Liquids/2m Solids 5kHz 2V DC Power supply U 9 to 26V C 5/6Hz lways 5 NSI Class 5 equivalent diameter and bolt holes IS K equivalent diameter and bolt holes mm /" for UW52 25mm /" for UW53 Sensor end For UW52 For UW53 Long range for Liquids & Solids Standard sensor material (Vibrating part Case : /Membrane : Polyolefine) Specification Code UW5 S T Range/ UW55 S T Frequency UW56 S 5 T 5 Power supply U lways 5 Integral C/DC supply sensor for long range Max. 5m Liquids/Solids khz Max. 6m Liquids/Solids 5kHz 2V DC 9 to 26V C 5/6Hz NSI Class 5 equivalent diameter and bolt holes IS K equivalent diameter and bolt holes 25mm/" for UW55/UW56 Sensor end For UW55 For UW56 TGEM6E TOKYO KEISO CO., LTD. 9
10 SOUNDM Ultrasonic Levelmeter UW 5 Series Remote Converter 2 wire loop powered Specification Code UWC52 Output S Remote converter 2 wire loop powered..2m DC lways (EEx i) C/DC powered Converter with 5 relays output Specification Code Power supply Output UWC5 S U C/DC powered Remote converter 2V DC 9 to 26V C 5/6Hz..2m DC lways Remote Sensor Short range for Liquids Standard sensor material for wetted part (Vibrating part Case, Membrane : ETFE) Specification Code UWS5 T 6 C Range/ UWS55 5 T 6 C Frequency UWS5 3 T 6 C Temperature range T T 2 T N 2 C 2 Remote sensor for short range Max. 5m Liquids 5kHz Max. m Liquids 3kHz Standard ( to 8 C) Thread mounting G2 male thread Thread mounting 2"NPT male thread lways C NSI Class 5 equivalent diameter and bolt holes IS K equivalent diameter and bolt holes mm /" ottom of sensor Without horn With horn (only with flange) Without horn (Please use in case use of focaliser horn) TOKYO KEISO CO., LTD. TGEM6E
11 SOUNDM Ultrasonic Levelmeter UW 5 Series Middle range for Liquids & Solids Standard sensor material (Vibrating part Case : /Membrane : PTFE) Specification Code UWS5 T C Remote sensor for middle range Range/ UWS52 2 T C Max. 2m Liquids/m Solids 2kHz Frequency UWS53 5 T C 5 Max. 3m Liquids/2m Solids 5kHz Temperature range T Standard ( to 8 C) C 5 lways C NSI Class 5 equivalent diameter and bolt holes IS K equivalent diameter and bolt holes mm /" for UWS52 25mm /" for UWS53 Sensor end For UWS52 For UWS53 Long range for Liquids & Solids Standard sensor material (Vibrating part Case : /Membrane : Polyolefine) Specification Code UWS5 C Range/ UWS55 C Frequency UWS56 5 C Temperature range S C 5 Remote sensor for long range Max. 5m Liquids/Solids khz Max. 6m Liquids/Solids 5kHz Standard ( to 8 C) lways C NSI Class 5 equivalent diameter and bolt holes IS K equivalent diameter and bolt holes 25mm /" for UWS56/ UWS56 Sensor end For UWS55 For UWS56 TGEM6E TOKYO KEISO CO., LTD.
12 SOUNDM Ultrasonic Levelmeter UW 5 Series STNDRD CCESSORIES Parameter sheet : Instruction Manual : OPTION Parameters setting and data sheet as per customer s request [Symbol : DS] ORDERING INSTRUCTIONS Specify the following when ordering :. Model and specification code Example) Integral sensor thread connection Model : UW525 Spec code : S5T6T2 Example) Integral sensor flange connection Model : UW525 Spec code : SS Example) Remot converter Model : UWC52 Spec code : S Example) Remote sensor flange connection Model : UWS53 Spec code : 5TC5 2. Option (If required) Please state in Symbol 3. Special request (If required) Please state special requests clearly. Consult TokyoKeiso or representative before ordering. Process condition Power supply : ( ) V C, ( ) V DC Environment : Outdoor use Indoor use Temperature in : Operation ( ) C, Design ( ) C the vessel Pressure in the : Operation ( ) C, Design ( ) C vessel mbient temperature : ( ) C Explosion proof : Required Intrinsically safe version Not required Vessel Type : Closed (atmospheric pressure) Pressurized ( ) bar, Open pit Close pit Shape : Cylindrical Horizontal Silo Other ( ) Roof type : Flat Conical Dome Other ( ) Vessel height : ( ) m Diameter or width : ( ) m Obstructions : gitator : No Yes : Type ( ) Others : Level switch Reinforce or Stay Ladder Temperature sensor or well Other ( ) Vessel material : Metal ( ) Non metal ( ) Coated : Yes No nozzle Height ( ) mm, Diameter ( ) mm Distance from the vessel wall ( ) mm Horizontal distance from the obstruction ( ) mm Horizontal distance from the inlet ( ) mm ORDERING INFORMTION Measuring condition Measuring range : Product The distance from the mounting nozzle to the minimum level : ( ) m The distance from the mounting nozzle to the maximum level : ( ) m Name : ( ) Material : Liquid Slurry Powder Pellet Corrosiveness : None Medium Strong Stickiness : None Medium Strong Crystalline : None Medium Strong Waving : None Medium Heavy Foam : None Medium High and dense * Specification is subject to change without notice. Head Office : Shiba Toho uilding, 7 2 Shibakoen, Minatoku, Tokyo Tel : (KEY) ; Fax : overseas.sales@tokyokeiso.co.jp ; URL : 2 TOKYO KEISO CO., LTD. TGEM6E
MAIN FUNCTION FEATURES. . D = v t /2
ttp e-te com e-ma l o e-te com LT ASONIC LE EL MEAS EMENT Tel -2-22 Fa -2-22 2 INTRODUCTION The ultrasonic level Indicator is a low-cost, noncontact and easy-to-install measurement device. It is able to
More informationUL350 ULTRASONIC FLOWMETER CLAMP-ON TYPE OUTLINE FEATURES MEASUREMENT PRINCIPLE
CLMP-ON TYPE UL350 ULTRSONIC FLOWMETER OUTLINE Our clamp-on type Ultrasonic Flowmeter UL350 has enabled applications to piping in various kinds by enhancing the permeation property of ultrasonic wave.
More informationCAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01
CAPACITIVE LEVEL SWITCHES Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01 HYCONTROL CAPACITIVE LEVEL SWITCH RANGE Hycontrol ME capacitive level switches provide simple, accurate and reliable level
More informationMAIN FUNCTION FEATURES. . D = v t /2
INTRODUCTION The ultrasonic level Indicator is a low-cost, noncontact and easy-to-install measurement device. It is able to meet the every-day needs of commercial production, as well serving a more specialized
More informationEGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
MAGMAX EGM53C Compact Electromagnetic Flowmeter GENERAL MAGMAX EGM53C is a combination of EGS5 primary head with Ceramic measuring tube and high performance converter EGC3. EGM53C with high durability
More informationUL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification
SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).
More informationEGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
EGMC Compact Electromagnetic Flowmeter GENERA MAGMAX EGMC is the compact type electromagnetic flowmeter with a converter EGC mounted integrally on a primary head EGS lined with fluorocarbon resin PFA.
More informationVFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification
SWIRMAX VFM4070C Vortex Flowmeter OUTINE SWIRMAX is 2-wire, all-in-one type vortex flowmeter with both temperature and pressure sensors integrally mounted into the housing. It allows temperature and pressure
More informationLevel measurement Guided microwave Product Information VEGAFLEX ma/hart. Level Switching Pressure
Level measurement Guided microwave Product Information VEGAFLEX 62 4 20 ma/hart Level Switching Pressure 2 VEGAFLEX 62 4 20 ma/hart Contents Contents 1 Product description...4 1.1 Configuration... 4 1.2
More informationNIVOCONT R VIBRATING ROD LEVEL SWITCHES
For solids NIVOCONT R VIBRATING ROD LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES O U R P R O F E S S NIVOCONT R VIBRATING ROD LEVEL SWITCHES MAIN FEATURES Extension up
More informationO-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON
MOST COST EFFECTIVE FLOW MEASUREMENT O-1000 Series ORIFLOMETER GENERAL O-1000 series ORIFLO METER is a flow meter consisting of an orifice plate and a metal tube variable area flow meter. Since the flow
More informationfor free flowing solids NIVOROTA ROTARY PADDLE LEVEL SWITCHES LEVEL SWITCHES
for free flowing solids NIVOROTA ROTARY PADDLE LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES MAIN FEATURES MAIN APPLICATION AREAS Level switching of free flowing solids
More informationSRT1000 Series THERMAL FLOWMETER
High-performance gas flowmeter SRT1000 Series THERMAL FLOWMETER OUTLINE Based on the long experienced know-how on the TOKYO KEISO's thermal flowmeters, SRT1000 series has enhanced its performance such
More informationCDT1000 series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION
QUICK FLOW CDT1 series Digital Flowmeter for ir Conditioning pplication OUTLINE CDT1 is a new series of flowmeter which combines a multidigital indicator with a pitot tube. CDT1 detects the differential
More informationQUICKSTART. Quickstart. A higher level of performance
QUICKSTRT higher level of performance Rev 1.1, Jan 2011 CONTENTS System Components 2 Flange & Cone ssembly 3 Wiring - Remote Units 4 - Integral Units 5 - Panel Mount Units 6 - Smart Units 7-4-20m Output
More informationUL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES MEASURING PRINCIPLE
SONICMAX UL63 Ultrasonic Clamp-on Flowmeter OUTLINE SONICMAX UL63 is the ultrasonic flowmeter of the time flight system which combined the highly efficient converter (UFC3) with the clamp-on sensor (UFS6).
More informationLevel Measurement Continuous level measurement - Radar transmitters
Overview Configuration Installation Note: Beam angle is the width of the cone where the energy density is half of the peak energy density Emission The peak energy density cone is directly in front of and
More informationCAPACITANCE LEVEL SWITCH
CAPACITANCE LEVEL SWITCH http: //www.fine-tek.com e-mail: info@fine-tek.com Tel: 886--696789 Fax: 886--68668 4 PRINCIPLE The capacitance level switch measuring principle is based on the "capacitance effects".
More informationUltrasonic Non Contact Sensors
3 Measuring Principle - An ultrasonic pulse is transmitted from the ABM sensor. The pulse 25-148 KHz travels to the surface being monitored and is reflected off this surface back to the sensor face. The
More informationST-50 SERIES ULTRASONIC TRANSDUCER
ST-50 SERIES ULTRASONIC TRANSDUCER Instruction Manual PL-418 December 1994 33454180 Rev 1.2 Thank you for purchasing Milltronics products. We endeavour to design equipment that is simple to use and reliable
More informationLevel Measurement Point level measurement - Vibrating switches
Siemens G 2018 SITRNS LVS200 Overview SITRNS LVS200 is a vibrating point level switch for high, low, or demand level detection of bulk solids. enefits High resistance to mechanical forces Strong vibration
More informationPROCAP Capacitance Level Sensors
PROCAP Capacitance Simple. Rugged. Reliable. Triple thread screw on/off cover - No more bolts! Unsurpassed sensitivity and stability No interference from RF signals Switch selectable high/low fail-safe
More information1000 Series MASSMAX. Coriolis Mass Flowmeter Straight Twin Tube OUTLINE FEATURES STANDARD SPECIFICATIONS. Fluid Specifications
MSSMX Series Coriolis Mass Flowmeter Straight Twin Tube OUTLINE MSSMX series is the coriolis mass flowmeters developed on the theme of the straight tube model which is excellent in cost performance. The
More informationLevel Measurement Continuous level measurement Ultrasonic transmitters
Siemens AG 2018 Overview Configuration ultrasonic level transmitter, ideal for level, volume, and volume flow measurements. It works with liquids, slurries, and bulk materials up to 12 m (0 ft). Benefits
More informationMobrey dry products level measurement and control
Product Data Sheet Mobrey offer a range of technologies for reliable point-level detection in a variety of dry solid applications The Mobrey Series PLS is a paddle rotating level switch that detects high
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationSTK2000/7400 Series. Flapper-type Flowmeter OUTLINE FEATURES PRINCIPLE STANDARD SPECIFICATIONS. Specifications of the metal measuring tube
STK2000/7400 Series Flapper-type Flowmeter OUTLINE The STK2000 and STK7400 are high-accuracy, high-performance, flapper-type flowmeters. The STK2000 is a local indication type, and the STK7400 is a local
More informationA6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM
Industrial Conductivity (Electric Conductivity) Detector A5/A6 type (For general multipurpose) AR4/AR5 type (for small purified water equipment) Dual electrode conductivity (electrical conductivity) detector
More informationUltrasonic Measurement prosonic FDU 80 86
Technical Information TI 189F/00/en Operating Instructions 015081-1007 Ultrasonic Measurement prosonic FDU 80 86 Sensors for non-contact, continuous measurement of level and flow. Suitable for use in explosion
More informationRotary Paddle Bin Monitor MODEL KA & KAX
Setting The Standard For Supplier Excellence Rotary Paddle Bin Monitor MODEL KA & KAX Hassle-Free Housing Design - No Bolts! Industry Leading Motor Shut-off Feature Economical, Versatile Point Level Bin
More informationUCM -04A/06A RoHS compliance
Converter integrate type ultrasonic flowmeter -4A/6A RoHS compliance ULTRASONIC COMPACT METER LE The -4A/6A is the converter integrate type ultrasonic flowmeter for small flow that offers precise an stable
More informationAM-2000 series HYBRID FLOWMETER
AM- series HYBRID FLOWMETER OUTLINE AM- series is a new all metal type flowmeter. AM- series integrates formerly separate functional devices to facilitate mounting in restricted spaces. Suitable for liquid,
More informationSoliswitch FTE30. Technical Information
Technical Information Soliswitch FTE30 Level limit switch Economical paddle limit switch with type-examination certificate to ATEX dust Ex-approval zone 20 Application The universal paddle level limit
More informationDIAMOND POINT VIBRATING PROBES
DIAMOND POINT VIBRATING PROBES DP130 DP120 DP140 DP150 Instruction Manual Third revision, April 2016 Hycontrol Ltd., Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, U.K. Tel: + 44 (0)1527
More informationSTOCKTROL-H VIBRATING LEVEL SWITCH. Instruction Manual June 2002
STOCKTROL-H VIBRATING LEVEL SWITCH Instruction Manual June 2002 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the
More informationLevel Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.
Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,
More informationNCR ma/hart four-wire
Quick Setup Guide Radar sensor for continuous level measurement of bulk solids NCR-80 4-20 ma/hart four-wire www.binmaster.com Mounting Mounting preparations, mounting strap The strap is supplied unassembled
More information1' to 10' deep and 1' to 25' deep
ULTRASONIC ECHO-SCALE TM SCALE: INDICATOR: ECHO-SCALE TM NONE PROVIDED electronic sensors for vessels 1' to 10' deep and 1' to 25' deep INSTALLATION & OPERATION s/n 1-800-893-6723 Fax: 925-686-6713 www.forceflow.com
More informationO-100 Series GLASS TUBE TYPE ORIFLOMETER BEST COST EFFECTIVE FLOW MEASUREMENT EVEN FOR LARGE SIZE LINES GENERAL STANDARD SPECIFICATION MODEL CODE
BEST COST EFFECTIVE FLOW MESUREMENT EVEN FOR LRGE SIZE LINES O-0 Series GLSS TUBE TYPE ORIFLOMETER GENERL O-0 series ORIFLO METER is a flow meter consisting of a orifice plate and a GLSS TUBE type variable
More informationPROCAP Capacitance Level Sensors
PROCAP Capacitance Level Sensors Simple. Rugged. Reliable. Triple thread screw on/off cover - No more bolts! Unsurpassed sensitivity and stability No interference from RF signals Switch selectable high/low
More informationSS Concentration Analyzer
SS Concentration nalyzer Model : SSD-6 (for Low Concentration Measurement) SSD-6 (for Medium Concentration Measurement) n SS concentration analyzer is an optically based measurement instrument for continuously
More informationJust Level. Table of Contents. Model CPH Capacitive Proximity Switch TECHNICAL INFORMATION. Principle of Operation 2. Applications 3.
Table of Contents Section Page Principle of Operation 2 Applications 3 Features 7 Options / Accessories 8 Ordering Information 13 Technical Data 14 1 P a g e Principle of Operation Introduction The BlueLevel
More informationLevel Measurement Products Installation Considerations-Ultrasonic
Siemens Industry, Inc / IA / Process Instruments Level Measurement Products Installation Considerations-Ultrasonic Restricted Siemens Industry, Inc. 2015 All rights reserved. Answers for industry. Ultrasonic
More informationTIDALFLUX 2300 F Quick Start
Quick Start Electromagnetic flow sensor for partially filled pipes The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS
More informationNEW. Level Transmitter 2.1. Data sheet
Data sheet Level Transmitter 2.1 NEW 1 ivision 1, D nsor Class e S d ve Appro GB 2.1 Shuttle 0708 We reserve the right to continuously improve our products and make any change in the stated specifications
More informationSensors do not overheat at zero flow by using a unique constant temperature control method and power limiting design
TECHNICL SPECIFICTIONS Multipoint Insertion Flow Meter Series K-BR 2000B The Kurz K-BR 2000B multipoint insertion flow meter for combustion control and emissions monitoring includes the qualities and features
More informationLevel Measurement Point level measurement - RF Capacitance switches
Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable
More informationFP-4000 Series FLOAT LEVEL SWITCH OUTLINE MAIN APPLICATIONS STANDARD SPECIFICATION
FOR MULTIPOINT LEVEL ALARM ETECTION BY ONE UNIT FP- Series FLOAT LEVEL SWITC OUTLINE The FP- series is a float level switch, which is installe through the tank nozzle on tanks an/or pits. Level alarm etection
More informationVortex Flowmeters VFM 3100 F-T VFM 3100 W-T
KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationROTARY PADDLE LEVEL SWITCHES
Paddle switch catalogue YC-PSC01 Iss. 03 ROTARY PADDLE LEVEL SWITCES LEVEL SWITCES FOR SOLIDS YCONTROL ROTARY PADDLE LEVEL SWITC YEAR WARRANTY on the motor assembly due to unique design features:- motor
More informationVibrating Level Switches for Liquids & Solids HYC-VLS02 Elect. Iss. 02 SIL 2 APPROVED VIBRATING LEVEL SWITCHES FOR LIQUIDS AND SOLIDS
Vibrating Level Switches for Liquids & Solids HYC-VLS02 Elect. Iss. 02 SIL 2 APPROVED VIBRATING LEVEL SWITCHES FOR LIQUIDS AND SOLIDS VIBRATING PROBE LEVEL SWITCHES FOR LIQUIDS AND SOLIDS PRINCIPLE OF
More informationCDT1000 Series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION
QUICK FLOW CDT1 Series Digital Flowmeter for Air Conditioning Application OUTLINE CDT1 is a new series of flowmeter which combines a multidigital indicator with a pitot tube. CDT1 detects the differential
More informationMobrey MSM400 Ultrasonic sludge density measurement system
Technical specification sheet IP257 October 2008 Mobrey MSM400 Ultrasonic sludge density measurement system Level Features Measuring range up to 50% solids Simple keypad operation HMI menu based programming
More informationGeneral Specifications
General Specifications Model DT450G Dust Monitor GENERAL Powder is used in many industries including ceramics,cement, chemicals, pharmaceutical and food. In their processes, powder is collected in order
More informationF-1500 SERIES INSERTION TURBINE FLOW METER
F-1500 SERIES INSERTION TURBINE FLOW METER APPLICATIONS Saturated steam Hot water to 450 F (232 C) standard 850 F (454 C) optional Applications with optional pressure sensor Superheated steam to 450 F
More informationThe Mobrey product range provides reliable point level detection in a variety of dry solid applications
Product Data Sheet June 2015 IP400, Rev DG Mobrey Dry Products Level Measurement and Control The Mobrey product range provides reliable point level detection in a variety of dry solid applications The
More informationZirconia Oxygen Gas Analyzers
Direct insertion type Zirconia Oxygen Gas nalyzers Detector type: ZFK8 / onverter type: ZKM ZKM ZKM ZKM ZFK8 ZFK8 Modular detector design allows easy field replacement of zirconia element nhanced safety
More informationSolidFlow. Monitoring of Solids. Product Information. SWR engineering Messtechnik GmbH
EN SolidFlow Product Information Monitoring of Solids SWR engineering Messtechnik GmbH Using SolidFlow is a sensor especially developed for measuring the flow rate of solids conveyed in metallic ducts.
More informationAM9000 Series GENERAL FEATURES METAL TUBE VARIABLE AREA FLOWMETER
METAL TUBE VARIABLE AREA FLOWMETER AM9000 Series GENERAL The AM9000 series metal tube variable area flowmeters have the unified face-to-face dimension mm. Having developed the current well-accepted AM7000
More informationOperating Instructions. Angle Seat Control Valve. Type 7020
Operating Instructions Angle Seat Control Valve Type 7020 With: Digital Positioner Type 8048 Electro-pneumatic Positioner Type 8047 Pneumatic Positioner Type 8047 Version: 02/2006 Manual-7020e.doc Art.-No:
More informationINTERNATIONAL METAL ENGINEERING
INDICATING TEMPERATURE TRANSMITTER WITH HART 8080HT UNIVERSAL SETTINGS WITH HART PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE TECHNOLOGY, 4 TO 20mA ANALOG OUTPUT HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE
More informationULTRASONIC FLOWMETER / HEATMETER
TUF-000F SERIES ULTRASONIC FLOWMETER / HEATMETER www.tuf-000. TUF-000F www. tuf- 000. CONTENTS OVER 0 YEARS' EXPERIENCES SPECIALIZED IN ULTRASONIC FLOW METERS PROFILE 1 Fixed Mounted Inline Type Ultrasonic
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response
ABB MEASUREMENT & ANALYTICS DATA SHEET AC00 Series Industrial -electrode conductivity cells with rapid temperature response AC00 SE RIE S I N DUST RI AL -ELE C TRODE CONDU C TIV IT Y C E LLS DS/AC CO-E
More informationLTX RF LEVEL SENSOR. Instruction Manual
LTX RF LEVEL SENSOR Instruction Manual FOR MODELS LTX01, LTX02, LTX05 Intempco Document No: LTX - M01 Rev. 1 Issue Date: April 2005 LTX01 RF LEVEL SENSOR USER MANUAL Software Rev : Rev. Date : June 2004
More informationPoint level measurement Capacitance switches
Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.
More informationETP80. Electronic Transmitter for Pressure, Differential Pressure and Level
ETP80 Electronic Transmitter for Pressure, Differential Pressure and Level The ETP80 is a series of pressure transmitters with a wide range of s to suit most applications. The transmitters can measure
More informationF-2700 SERIES INSERTION VORTEX FLOW METER
F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260
More informationLevel Limit Switch soliphant FTM 930/931/932/ Z
Technical Infmation TI 042F/00/e Level Limit Switch soliphant FTM 930/931/932/ Z F Universal Application with Bulk Materials and Dust Ex Area Application The Soliphant has a wide range of safe applications
More informationMetal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam
Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,
More informationHoneyville Cyclones. Sizes Ranging from 575 CFM to 57,000 CFM
Honeyville Cyclones Sizes Ranging from 575 CFM to 57,000 CFM Centrifugal Cyclone Collectors FEATURING Twenty-six Standard Models for a Large Range of Applications. All Welded Carbon Steel, Butt Seam Construction
More informationThermocouples TE Measuring Insert. rigid Model TC 001 flexible Model TC 002. Electronic Temperature Measurement
TE 65.01 Thermocouples Measuring Insert Electronic Temperature Measurement rigid Model TC 001 flexible Model TC 002 Services intended Exchangeable measuring insert for all industrial and laboratory applications.
More informationSATRON VVFe Pressure Transmitter
SATRON VVFe pressure transmitter belongs to Vtransmitter family. SATRON VVFe is used for 0 4 kpa...0500 kpa ranges. It is a 2wire transmitter with HART standard communication. SATRON VVFe pressure transmitter
More informationLevel Sensors and Switches Guided Radar (TDR) Radar Wave Level Sensors Ultrasonic Level Sensors Rotating Paddle Level Switches Vibrating Fork Level
Level and Switches Level Level Applications Suitable for the applications in the field of chemical plastics, pharmaceutical manufacturing, fodder, grains, cement, fertilizer, powder, fuel materials, hydraulic
More informationMasoneilan Series
Masoneilan 12300 Series Digital Level Transmitter & Controller Specification Data CU3000 02/02 Digital Level Measurement and Control Instrumentation Table of Contents General Description...2 Principle
More informationProduct Overview SKRD31 Features: Rope probe Application: liquid or solids level Range: 30m Process connection: thread, flange Process temperature: -4
SKRD 30 Series Guided Wave Radar Level Meter Principle High frequency microwave pulses travels along the detecting component (steel rope or rod) and reflects when reaching the product surface. The time
More informationTUNING FORK LEVEL WORKING PRINCIPLE APPLICATION. Solid Level Detection FEATURE. For Liquid: * Water & Solutions * General Purpose Solvent * Petroleum
TUNING FORK LEVEL WORKING PRINCIPLE The tuning fork of level switch operated by using two piezoelectric elements built-in on vibration tube. The first piezoelectric element triggered by pulse signal that
More informationA Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >
Higher Level of Performance Data Sheet Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com / Dimensions Centurion Guided Wave Radar Radar Principle of Operation Guided-wave
More informationLevel Limit Switch soliphant II FTM 30 (D/S), FTM 31 (D/S), FTM 32 (D/S)
Technical Information TI 9F/00/en Level Limit Switch soliphant II FTM 0 (D/S), FTM (D/S), FTM (D/S) Universal vibration limit switch for fine-grained bulk solids Suitable for dust explosion hazardous areas
More informationTECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES
TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS "" includes all sensors that detect the presence of a metallic object approaching the sensing face or near the sensing face without mechanical contact.
More informationCVR-625. Compact Vibrating Rod Instruction Manual
CVR-625 Compact Vibrating Rod Instruction Manual BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS
More informationSeries 500. Liquid Level Transmitters. Instruction Manual
Series 500 Liquid Level Transmitters Instruction Manual Contents Section Content Page 1 Introduction 1.1 General Overview 3 1.2 Mounting Options 3 2 Installation Notes 2.1 Transmitters 4 2.1.1 Model 510
More informationDIRECT IMMERSION RESISTANCE THERMOMETER CONFIGURATIONS
DIRECT IMMERSION RESISTANCE THERMOMETER CONFIGURATIONS WELDED THREADED CONNECTION II 1G/D Ex ia Pt100KI D20 D21 D26-1 D26-2 1 FEATURES The industrial thermometer configuration guarantees a short response
More informationEccentric Rotary Control Valve (For size 1 to 4 inches)
No. SS2-VFR100-0200 FloWing Eccentric Rotary Control Valve (For size 1 to 4 inches) Model VFR OVERVIEW The eccentric rotary control valve, FloWing (model VFR), consists of a straight-through valve body
More informationMagnetic Level Gauges
Magnetic Level Gauges Instrumentation Division > Immediate and accurate response to level changes, giving clear and sharp legibility. > Continuous indication of liquid level. The well proven TC Klinger
More informationSATRON VDt Differential Pressure Transmitter
SATRON VDt differential pressure transmitter belongs to V-transmitter family. The series V transmitters have both analog and smart properties. SATRON VDt is used for -,1kPa...-15 MPa ranges. It is a 2-wire
More informationSuper-Safe-Plus Roto-Bin-Dicator
Super-Safe-Plus Roto-Bin-Dicator for your most demanding applications... Offers both mechanical and electronic sensing in one reliable Point Level Sensor... Level control with added confidence Under normal
More informationBucket Elevator Belt Bucket Conveyor
Bucket Elevator TD belt bucket conveyor is suitable for density less than.5t/m3 lump, granular material such as coal, cement, fertilizer, sand, grain, etc.belt bucket conveyor has two types of bucket:
More informationSoliswitch FTE20. Technical Information. Point level switch for granular solids
Technical Information Point level switch for granular solids Applications The is a paddle switch for granular solids. Its robust and compact design makes the point level switch an ideal sensor for detecting
More informationBGN. All Metal Variable Area Flow Meter. Technical Data Sheet
All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of
More informationSmartBob AO. BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE
BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0312 Rev B TABLE OF
More informationMagnetic Level Gauges
Magnetic Level Gauges Instrumentation Division > Immediate and accurate response to level changes, giving clear and sharp legibility. > Continuous indication of liquid level. The well proven TC Fluid Control
More informationROTARY PADDLE TYPE LEVEL SWITCH
ROTRY PDDE TYPE EVE SWITCH N Series Rotary Type NM Series Rotary Type NN Series Reversible Type F-GM Series Rotary Type NNM Series Reversible Type Flame-proof dg Uncomparable models developed based on
More informationHG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS
H5 Series Metal Tube Rotameter H5 series metal tube rotameter (also called variable area flow meter) is a kind of measuring meter which the flow rate is changing along with the area and is widely used
More informationSERIES 454FTB-WGF TECHNICAL SPECIFICATIONS
Complex Technology Made Simple Insertion Flow Meter SERIES 454FTB-WGF TECHNICL SPECIFICTIONS The Kurz WGF single point insertion flow meter for wet gas environments includes the qualities and features
More informationThree Way Control Valves
No. SS2-HDT110-0100 Three Way Control Valves Model HDT OVERVIEW The valve model HDT is a three-way control valve for diverting service. It has a small-sized, high-output diaphragm motor which is suitable
More informationPitoMaster FPD550 Compact averaging pitot flowmeter. Economical flow metering solutions for gases, liquids and steam
Data sheet DS/FPD550 EN Rev. C PitoMaster FPD550 Compact averaging pitot flowmeter Economical flow metering solutions for gases, liquids and steam Compact flowmeter with integral transmitter, manifold
More informationPressure transmitters for heavy-duty applications MBS 2000 and MBS 2050
Data sheet Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050 The compact heavy duty pressure transmitters MBS 2000 and MBS 2050 are designed for use in hydraulic applications. MBS
More informationSITRANS F C MASSFLO Practical examples of ordering. MASS2100 & MASS6000 IP67 Compact mounted
SITRNS F C MSSFLO MSS2100 & MSS6000 IP67 Compact mounted Mass 2100 sensor DI 3 - DI 40 MSS 6000 IP67 transmitter. Use ordering code FI 01 Catalogue p. 4/140 MSS system: 7ME4100-2EC21-2D1 FI 01 catalogue
More informationUltrasonic Two-Wire Point Level Control
Ultrasonic Two-Wire Point Level Control General Instructions The Ultrasonic Point Level Control indicates liquid presence/absence within a sensor cavity. Two piezoelectric crystals face each other across
More informationprocess measurement solutions The dry products level control catalogue
process measurement solutions The dry products level control catalogue 1 Dry products level measurement and control from Solartron Mobrey The measurement and control of dry products is important in all
More information