OE & OE Digital Room Sensor

Size: px
Start display at page:

Download "OE & OE Digital Room Sensor"

Transcription

1 The OE217 series of Touch Screen Digital Room Sensors are used to sense Space Temperature only or Space Temperature & Space Humidity. The OE is a Space Temperature Sensor only and the OE is a combination Space Temperature & Space Humidity Sensor. Both are used with the VCM-X E-BUS Controller. OE & OE Digital Room Sensors Besides sensing Temperature & Humidity, the Digital Room Sensors also provide these other useful features: User Friendly Graphical LCD Display with LED Backlight Display the Current Space and Outdoor Air Temperature Display the Current Space Humidity and Outdoor Air Relative Humidity (OE Model Only) Display the current Zone Setpoint Temperature Equipped With Push Buttons for Changing the Zone Setpoint Temperature Equipped With an Override Button for Forcing the VCM-X E-BUS Controller into Occupied Operation from Unoccupied Operation Provides graphics to indicate the mode of operation Provides LEDs to indicate Schedule Override, Button Push, and Alarms Both sensors connect to the controllers using TSDRSC modular cables of multiple lengths connected between the controller and the sensor. The TSDRSC modular cables should not run in conduit with other AC line voltage wiring or with any conductors carrying highly inductive loads. Mounting The Digital Room Sensor is designed to be mounted to a vertical, 2 x 4 electrical box recessed in the wall. If the wall cannot be penetrated, a plastic surface mount box such as those made by Wiremold TM, may be used to mount the sensor to the wall surface. The Sensor is mounted by removing the front cover and fastening the housing base to the electrical box using the supplied (2) 6/32 x 1 machine screws. The Modular cable is then plugged into the phone jack located on the circuit board that is mounted on the cover. The cover is then placed onto the housing base and the Allen Screw on the bottom of the base is adjusted to hold the cover in place. Sensor Element Sensor Reading Range Ambient Temperature Limits Accuracy Three Year Warranty Type III Thermistor 10k 77 F Digital Sensing Device 40 F to 120 F RH = 0-100% OE & OE Digital Room Sensor Display 112 x 64 Monochrome Graphical LCD w/led Backlight Connection RJ-45 Modular Female Jack -40 F to 180 F Weight 3.2 oz. RH +/- 3%, Temp +/-.8 F AAON reserves the right to change specifications without notice. Form: ORION-OE DigitalRoomSensor-1G.doc Page 1 of 1

2 TSDRSC-XX Digital Sensor Cable The TSDRSC Cables are used to connect power and communications between the WattMaster Digital Room Sensor or Digital CO 2 Sensor and the VCM-X Controller or VAV/Zone Controller. The TSDRSC Cables are prefabricated plenum-rated cables with RJ- 45 Connectors on both ends of the cable for connection between the Digital Room Sensor, Digital CO 2 Sensor, and the VCM-X or VAV/Zone Controller. The TSDRSC Cables are labeled near each end with the cable part number. The TSDRSC Cables are available in 5, 10, 15, 25, 40, 80, 120 & 160 feet lengths. These lengths should satisfy most job requirements. For length requirements other than those listed, the MS Modular Room Sensor Cable Coupler can be used to connect two of the TSDRSC Cables together to provide for your specific-length requirements. The plug-in design of the TSDRSC Cables eliminates costly wiring errors and makes system installation easy. The cable components are all UL approved. TSDRSC Cable Available Lengths and Part Numbers TSDRSC-5 (5 Ft.) TSDRSC-10 (10 Ft.) TSDRSC-15 (15 Ft.) TSDRSC-25 (25 Ft.) TSDRSC-40 (40 Ft.) TSDRSC-80 (80 Ft.) TSDRSC-120 (120 Ft.) TSDRSC-160 (160 Ft.) Current Rating of Cable Wire TSDRSC Digital Sensor Cables 24 AWG Wire = Amps (Maximum Amps For Power Transmission) Cable Type Plenum-rated Wire Colors Brown, Blue, White W/ Blue Stripe, White W/ Brown Stripe, Orange, White W/ Orange Stripe, Green, White W/ Green Stripe Wire Size 24 AWG Stranded 8 Conductor UL Listing No. CMP-UL As Per UL 910 Terminations Three Year Warranty (2) RJ-45 Connectors Cable Sheath Color Gray WattMaster reserves the right to change specifications without notice Form: ORION-ModularCable-TSDRSC-1A.doc Page 1 of 1

3 The OE217 series of Touch Screen E-BUS Digital Room Sensors are used to sense Space Temperature only or Space Temperature & Space Humidity. The OE model is the Space Temperature Sensor only model and can be used with the VCCX2 Controller, VCC-X Controller or VCB-X Controller and the VAV/Zone Controller. The OE is a combination Space Temperature & Space Humidity Sensor model and can only be used with the VCCX2, VCC-X or VCB-X Controller. Besides sensing Temperature & Humidity, the E-BUS Digital Room Sensors also provide these other useful features: User Friendly Graphical LCD Display with LED Backlight Display the Current Space and Outdoor Air Temperature Display the Current Space Humidity and Outdoor Air Relative Humidity (OE Model Only) Display the current Zone Setpoint Temperature Equipped With Push Buttons for Changing the Zone Setpoint Temperature Equipped With an Override Button for Forcing the VAV/Zone Controller or VCB-X Controller into Occupied Operation from Unoccupied Operation Provides graphics to indicate the mode of operation Provides LEDs to indicate Schedule Override, Button Push, and Alarms OE & OE E-BUS Digital Room Sensors Both sensors connect to the controllers using E-BUS cables of multiple lengths connected between the controller and the sensor. The E-BUS cables should not run in conduit with other AC line voltage wiring or with any conductors carrying highly inductive loads. Mounting The Digital Room Sensor is designed to be mounted to a vertical, 2 x 4 electrical box recessed in the wall. If the wall cannot be penetrated, a plastic surface mount box such as those made by Wiremold TM, may be used to mount the sensor to the wall surface. The Sensor is mounted by removing the front cover and fastening the housing base to the electrical box using the supplied (2) 6/32 x 1 machine screws. The E-BUS cable is then plugged into the E-BUS connector located on the circuit board that is mounted on the cover. The cover is then placed onto the housing base and the Allen Screw on the bottom of the base is adjusted to hold the cover in place. An additional cover plate is provided in case the sheet rock cut-out is too large to be covered by the regular back plate. Sensor Element Sensor Reading Range Ambient Temperature Limits Accuracy Three Year Warranty Type III Thermistor 10k 77 F Digital Sensing Device 40 F to 120 F RH = 0-100% OE & OE E-BUS Digital Room Sensor Display 112 x 64 Monochrome Graphical LCD w/led Backlight Connection E-BUS -40 F to 180 F Weight 3.2 oz. RH +/- 3%, Temp +/-.8 F AAON reserves the right to change specifications without notice. Form: ORION-OE EBUS-DRS-1C.doc Page 1 of 1

4 SHLD -COM GND +12Vdc OE E-BUS Digital Room Sensor The OE E-BUS Digital Room Space & Humidity Sensor is used to sense Space Temperature & Space Humidity. The E-BUS Digital Room Sensor can be used with the VCCX2 or VCB-X Controller The E-BUS Digital Room Sensor connects to the controller using E-BUS cables of multiple lengths connected between the controller and the sensor. The E-BUS cables should not run in conduit with other AC line voltage wiring or with any conductors carrying highly inductive loads Mounting The E-BUS Digital Room Sensor is designed to be mounted to a vertical, 2 x 4 electrical box recessed in the wall. If the wall cannot be penetrated, a plastic surface mount box such as those made by Wiremold TM, may be used to mount the sensor to the wall surface. The Sensor is mounted by removing the front cover and fastening the housing base to the electrical box using the supplied (2) 6/32 x 1 machine screws. The E-BUS cable is then plugged into the E- BUS connector located on the circuit board that is mounted on the cover. The cover is then placed onto the housing base and the Allen Screw on the bottom of the base is adjusted to hold the cover in place. E-BUS Cable Connection 1.87 Remote Thermistor Sensor Connector Front View MICROCHIP PIC24HJ 256GP206 Cover Set Screw Side View Back View Sensor Element Sensor Reading Range Ambient Temperature Limits Three Year Warranty Digital Capacitive Sensing Device 40 F to 120 F RH = 0-100% Accuracy Connection OE E-BUS Digital Room Sensor RH +/- 3%, Temp +/-.8 F E-BUS -40 F to 180 F Weight 3.2 oz. AAON reserves the right to change specifications without notice. Form: ORION-OE EBUS-DRS-1B.doc Page 1 of 1

5 BK Sensor Mounting Plate The BK00081 Sensor Mounting Plate is used, if necessary, to cover the Sensor sheet rock opening. It is provided with the following Sensors: OE Digital Room Temperature Sensor OE Digital Room Temperature and Humidity Sensor OE E-BUS Digital Room Temperature Sensor OE E-BUS Digital Room Temperature and Humidity Sensor OE E-BUS Digital Room Temperature Sensor (No LCD Display) OE Wall Mounted CO 2 Sensor OE E-BUS Wall Mounted CO 2 Sensor Mounting The Mounting Plate screws onto the back of the Sensor s housing base. The mounting plate is then mounted and covers the recessed space in the wall. A locking screw secures the Sensor to the wall. Form: ORION-BK Sensor-Mounting-Plate-1A.doc Page 1 of 1

6 MS E-BUS Adapter Hub The MS E-BUS Adapter Hub is used to provide a connection point for multiple E- BUS Sensors or Modules. This E- BUS Adapter Hub has four ports. One port is used to connect the Hub to an E-BUS Expansion Port on the VCB-X Controller or a VCB-X Expansion Module using EBC E-BUS cables. This leaves three ports available for E-BUS Sensors and other Modules. The EBC Cables are plenum-rated high flex wire cables with an EBC Connector on each end of the cable for connection between the Sensors, Modules, and the VCB-X Controller AMP ADAPTER HUB RIGHT END VIEW ADAPTER HUB TOP VIEW ADAPTER HUB SIDE VIEW ADAPTER HUB LEFT END VIEW MS E-BUS ADAPTER HUB Terminations Hub - (4) EBC Connectors Three Year Warranty MS E-BUS Adapter Hub WattMaster reserves the right to change specifications without notice. Form: AAON-MS E-BUS-Adapter-1A.doc Page 1 of 1

7 HZ-EBC E-BUS Adapter Hub with 1.5 Ft. EBC Cable The HZ-EBC-248 (AAON Part No. V17180) is comprised of the MS E-BUS Adapter Hub and a 1.5 Foot EBC Cable (Part No. EBC-1.5F). The E-BUS Adapter Hub is used to provide a connection point for multiple E-BUS Sensors or Modules. This E-BUS Adapter Hub has four ports. One port is used to connect the Hub to an E-BUS Expansion Port on the VCB-X Controller or a VCB-X Expansion Module using the supplied EBC- 1.5F cable. This leaves three ports available for E-BUS Sensors and other Modules. The EBC Cable is a plenum-rated high flex cable with EBC Connectors on each end of the cable for connection between the Sensors, Modules, and the VCB-X Controller. EBC E-BUS Cable Available Length and Part Number EBC-1.5F (1.5 Foot) HZ-EBC-248 E-BUS Adapter Hub with 1.5 Ft. EBC Cable Current Rating of Cable Wire 300 Vrms Min = Ohms per Deg Celsius, Nominal Cable Type Plenum-rated High Flex Wire Wire Colors Red/Black First Pair; White/Blue Second Pair Wire Size 19 Strands of 32 Gage Wire, 4 UL Listing No. CMP/CL3P/FPLP Conductor Terminations Hub - (4) EBC Connectors Cable 2 EBC Connectors Cable Sheath Color White, Plenum Rated CL3P/CMP with WATTMASTER EBUS marking every foot. Three Year Warranty WattMaster reserves the right to change specifications without notice Form: AAON-HZ-EBC-248-E-BUS-Adapter-1A.doc Page 1 of 1

8 OE EBA-A - E-BUS Adapter Board The OE EBA-A E-BUS Adapter Board is used to provide a connection point for multiple E- BUS Sensors or Modules The E-BUS Adapter Board is also used for connecting an EBTRON GTC-116 Airflow Measurement Digital Transmitter or a Green- Trol TM GA-200-N Transmitter Module with GF Series Airflow Monitoring Station to the VCM-X E-BUS Modular Controller*, RNE Controller*, or VCB-X Controller. P1 J1 P2 J2 MODULAR EBUS J3 YS REV 0 MADE IN USA MSTP EBUS R+ SH T- R+ SH T You must wire the EBTRON or GreenTrol TM Airflow Measurement Digital Transmitter to this Adapter Board. Up to (3) EBTRON or GreenTrol TM Airflow Measurement Digital Transmitters can be attached to the Adapter Board when using the VCM-X E-BUS Controller or RNE Controller and up to (4) EBTRON or GreenTrol TM Airflow Measurement Digital Transmitters can be attached to the Adapter Board when using the VCB-X Controller. The E-BUS Adapter Board has (3) HSSC Connections. One of these E-BUS ports is used to connect the Board to the E-BUS Port on the VCM-X E-BUS Controller or RNE Controller using an HSSC E- BUS cable. The E-BUS Adapter Board also has (4) Modular E-BUS ports. One of these Modular E-BUS ports is used to connect the Board to the E-BUS Port on the VCB-X Controller. The EBUS Adapter Board also has (2) MSTP E-BUS Connections. The AirFlow Monitoring Station(s) connect to one of the MSTP E-BUS Connections. *NOTE: With custom VCM-X software, the Paragon MicroTrans EQ series Air Flow Monitoring Station can be used and would wire into the E-BUS Adapter Board the same way. Terminations Three Year Warranty (4) EBC Connections (2) MSTP E-BUS Connections (3) HSSC Connections OE EBA-A E-BUS Adapter Board WattMaster reserves the right to change specifications without notice. EBTRON is a registered trademark of Ebtron, Inc., Loris, SC. GreenTrol TM is a registered trademark of GreenTrol Automation, Inc. Loris, SC. Paragon is a registered trademark of Paragon Controls, Inc. Santa Rosa, CA Form: ORION-OE EBA-A-E-BUS-Adapter-Board-1C.doc Page 1 of 1

9 EBC-XXXF EBC E-BUS Cables The EBC E-BUS Cables are used to connect power and communications between the VCB-X Controller, VCB-X Expansion Module, E-BUS Modules, and E-BUS Sensors. The EBC E-BUS Cables are plenumrated high flex wire cables with an EBC Connector on each end of the cable. The EBC E-BUS Cables are labeled with WATTMASTER E-BUS marking every foot. The EBC E-BUS Cables are available in 1, 1.5, 3, 10, 15, 25, 50, 75, 100, 150, and 250 foot lengths and additionally a 1000 foot long spool. These lengths should satisfy most job requirements. For length requirements other than those listed, the MS E-BUS Adapter Hub can be used to connect EBC E-BUS Cables together to provide for your specific-length requirements. The plug-in design of the EBC E-BUS Cables eliminates costly wiring errors and makes system installation easy. The cable components are all UL approved M EBC-XXF "WATTMASTER EBUS" "WATTMASTER EBUS" EBC- XX F M CABLE SIDE VIEW Length in Feet EBC E-BUS Cable Available Lengths and Part Numbers EBC-1-F (1 Foot) EBC-1.5-F (1.5 Foot) EBC-3-F (3 Foot) EBC-25-F (25 Foot) EBC-50-F (50 Foot) EBC-75-F (75 Foot) EBC-100-F (100 Foot) EBC-150-F (150 Foot) EBC-250-F (250 Foot) EBC-SPOOL-F (1000 Foot Spool) Current Rating of Cable Wire EBC-XXF E-BUS CABLE EBC-XXXF EBC E-BUS Cables 300 Vrms Min = Ohms per Deg Celsius, Nominal Cable Type Plenum-rated High Flex Wire Wire Colors Red/Black First Pair; White/Blue Second Pair Wire Size 19 Strands of 32 Gage Wire, 4 UL Listing No. CMP/CL3P/FPLP Conductor Terminations Cable 2 EBC Connectors Cable Sheath Color White, Plenum Rated CL3P/CMP with WATTMASTER EBUS marking every foot. Three Year Warranty WattMaster reserves the right to change specifications without notice Form: ORION-EBC-XXXF-E-BUS-Cable-1B.doc Page 1 of 1

10 THERM1 YS REV 0 PJ1 R2 R1 The patented design, OE21x-02 series Modular Room Sensor provides accurate sensing of the room temperature. Its design allows for flush wall mounting yet rejects the influence of surface and internal wall temperatures. The Modular Room Sensor is used in conjunction with the Orion VAV/Zone Controller. Connection between the VAV/Zone Controller board and the Modular Room Sensor is by means of an RJ-45 Modular Cable. The Modular Room Sensor cannot be used for connection to the VCM- X controller. For these applications the Standard Room Sensor must be used. Please see the Orion Standard Room Sensor submittal sheet for information. Sensors provided with the setpoint adjustment option can be programmed to allow a temperature range adjustment of ± 6 F from their standard setpoint. Sensors provided with the pushbutton override option can be programmed to provide a timed override duration of up to 8.0 hours. The Room Sensor s attractive styling and off white casing color make it suitable for most building decors. If interior decoration requires, the Modular Room Sensor casing can also be painted or wall papered without affecting the sensor's performance. Modular Room Sensors are available in 4 different configurations: OE210-02, , , Modular Room Sensors W A R M E R C O O L E R 2.00 MODULAR SENSOR " Wall Cut-Out Dimensions When Sensor Is To Be Mounted Without Handy Box (By Others) OE Sensor Plain OE Sensor with Override OE Sensor with Setpoint Adjustment OE Sensor with Setpoint Adjustment and Override Modular cable from the VAV/Zone Controller to the Modular Room Sensor should not be run in conduit with other AC line voltage wiring, or with any conductors carrying highly inductive loads. Mounting The Room Sensors are designed to be mounted on a vertical, 2 x 4 electrical box recessed in the wall. If the wall cannot be penetrated, a plastic surface mount box such as those made by Wiremold, may be used to mount the sensor to the wall surface. OE210-02, OE211-02, OE212-02, OE Modular Room Sensor Sensor Element Type III Thermistor 10k 77º F Mounting Designed to be Flush Mounted to Wall using Vertical 2 x 4 Handy Box (by others) Accuracy 0.4º F between 40º F to 95º F Connection RJ-45 Modular Female Jack Range -30º F to 150º F Weight 4 oz. 3 Year Warranty WattMaster reserves the right to change specifications without notice Form: ORION-ModularRoomSensor-1F.doc Page 1 of 1

11 FMRSC-XX Modular Room Sensor Cable The FMRSC Cables are used to connect power and communications between the Modular Room Sensor and the Orion VAV/Zone Controller. The FMRSC Cables are prefabricated plenum-rated cables with RJ- 45 Connectors on both ends of the cable for connection between the Modular Room Sensor and the Orion VAV/Zone Controller. The FMRSC Cables are labeled near each end with the cable part number. The FMRSC Cables are available in 5, 10, 25, 40 and 80 feet lengths. These lengths should satisfy most job requirements. For length requirements outside of this range, the MS Modular Room Sensor Cable Coupler can be used to connect two of the FMRSC Cables together to provide for your specificlength requirements. Not more than one coupler should be used on a run. Maximum run is 160 feet. The plug-in design of the FMRSC Cables eliminates costly wiring errors and makes system installation easy. The cable components are UL approved. FMRSC Cable Available Lengths and Part Numbers FMRSC-5 (5 Ft.) FMRSC-10 (10 Ft.) FMRSC-25 (25 Ft.) FMRSC-40 (40 Ft.) FMRSC-80 (80 Ft.) Current Rating of Cable Wire FMRSC Modular Sensor Cables 24 AWG Wire = Amps (Maximum Amps For Power Transmission) Cable Type Plenum-rated Wire Colors White W/ Green Stripe, Green W/ White Stripe, White W/ Orange Stripe, Orange W/ White Stripe, White W/ Blue Stripe, Blue W/ White Stripe Wire Size 24 AWG Stranded 6 Conductor UL Listing No. CMP-UL As Per UL 910 Terminations Three Year Warranty (2) RJ-45 Connectors Cable Sheath Color Gray WattMaster reserves the right to change specifications without notice Form: ORION-ModularCable-FMRSC-1B.doc Page 1 of 1

12 The patented design, OE21x series Standard Room Sensor provides accurate sensing of the room temperature. Its design allows for flush wall mounting yet rejects the influence of surface and internal wall temperatures. The Standard Room Sensor is used in conjunction with the Orion controllers. Wire terminals are provided on the sensor for connection to the controllers. The Standard Room Sensor cannot be used for connection to the VAV/Zone controller. For this application the Modular Room Sensor must be used. Please see the Orion Modular Room Sensor submittal sheet for information. OE210, 211, 212 & 213 Standard Room Sensors W A R M E R C O O L E R " Sensors provided with the setpoint adjustment option can be programmed to allow a temperature range adjustment of ± 6 F from their standard setpoint. Sensors provided with the pushbutton override option can be programmed to provide a timed override duration of up to 8.0 hours The Room Sensor s attractive styling and off white casing color make it suitable for most building decors. If interior decoration requires, the Room Sensor casing can also be painted or wall papered without affecting the sensor's performance. Room Sensors are available in 4 different configurations: TMP GND AUX OUT 2.75 Wall Cut-Out Dimensions When Sensor Is To Be Mounted Without Handy Box (By Others) OE210 Sensor Plain OE211 Sensor with Override OE212 Sensor with Setpoint Adjustment OE213 Sensor with Setpoint Adjustment and Override Mounting The Room Sensors are designed to be mounted on a vertical, 2 x 4 electrical box recessed in the wall. If the wall cannot be penetrated, a plastic surface mount box such as those made by Wiremold, may be used to mount the sensor to the wall surface. W A R M E R W A R M E R OVR C O O L E R OVR C O O L E R OE210 OE211 OE212 OE213 Room Sensor - Plain Room Sensor With Override Room Sensor With Setpoint Adjust Room Sensor With Setpoint Adjust & Overide OE210, OE211, OE212, OE213 Standard Room Sensor Sensor Element Type III Thermistor 10k 77º F Mounting Designed to be Flush Mounted to Wall using Vertical 2 x 4 Handy Box (by others) Accuracy 0.4º F between 40º F to 95º F Line Loss 0.25º F max. error, using 22 AWG wire at 1000 ft Range -30º F to 150º F Weight 4 oz. 3 Year Warranty WattMaster reserves the right to change specifications without notice Form: ORION-StandardRoomSensor-1D.doc Page 1 of 1

13 Duct Temperature Sensors OE230 (6" Probe) & OE231 (12" Probe) Caution! The Duct Sensor Is Used For Sensing Supply Or Return Air Temperatures. Location Of The Sensors Is Very Important In Order To Obtain Accurate Temperature Readings. The Following Recommendations Should Be Followed: Supply Air When Used As A Supply Air Sensor The Sensor Should Be Mounted In The Supply Air Duct As Close To The HVAC Unit As Possible And Upstream Of The Bypass Damper (If Used) For Best Results. For Best Accuracy, Apply Insulation On The Outside Of The Ductwork Over The Sensor. This Will Help Thermal Gradients From Affecting The Sensor. Return Air When Used As A Return Air Sensor The Sensor Should Be Mounted In The Return Air Duct As Close To The HVAC Unit As Possible And Upstream Of The Bypass Damper (If Used) For Best Results. For Best Accuracy, Apply Insulation On The Outside Of The Ductwork Over The Sensor. This Will Help Thermal Gradients From Affecting The Sensor. See The Systems Installation And Operation Manual For Other Design Considerations And Recommendations Regarding Duct Temperature Sensor Location. Thread Together Leads Are Non-polarized. Butt Splice Leads To 24 Gauge Wire Minimum. Connect Leads To "Analog In" And "Ground" At Controller. 3/4" 5-1/2" (OE230) Mounting Plate 11-1/2" (OE231) Mounting Plate Gasket 4.0" 1/4" Hex Head Sheet Metal Screws Adhesive Backed Drill Guide Mounting Template Duct Work Drill 3/8 Hole In Ductwork For Probe Temp Resistance* Voltage F Input* Temperature Sensor Resistance/Voltage Chart Temp Resistance* Voltage F Input* Temp Resistance* Voltage F Input* Temp Resistance* Voltage F Input* *Chart Notes: 1. Use the resistance column to check the thermistor sensor while disconnected from the controllers (not powered). 2. Use the voltage column to check sensors while connected to powered controllers. Read voltage with meter set on DC volts. Place the "-"(minus) lead on GND terminal and the "+"(plus) lead on the sensor input terminal being investigated. If the voltage is above 5.08 VDC, the sensor or wiring is "open." If the voltage is less than 0.05 VDC, the sensor or wiring is shorted. Technical Specifications Sensor Element: Type III Thermistor 10k 77ºF Accuracy: 0.4º F between 40º F to 95º F Range: -30º F to 150º F Notes: 1.)All Wiring To Be In Accordance With Local And National Electrical Codes And Specifications. JOB NAME FILENAME G-DUCSENS1.CDR DATE: 07/13/15 DRAWN BY: B. CREWS PAGE DESCRIPTION: OE230 & OE231 1 Duct Temperature Sensor

14 Gasketed Cover CAUTION! See Note Cover Mounting Screw - Typ Closure Plug CAUTION! See Note " Dia. x 0.73 Lg. Slot - Typ Mounting Tab & Screws - Typ Mounting Tab & Screw - Typ Closure Plug CAUTION! See Note 2 Incorrect Sensor Tube CAUTION! See Note 1 See Note #1 Front View Side View Back View Technical Specifications Sensor Element: Type III Thermistor 10k 77ºF Accuracy: 0.4º F between 40º F to 95º F Range: -30º F to 150º F Incorrect Correct Sensor Mounting Postion Temp Resistance* Voltage F Input* Outside Air Sensor OE250 Temperature Sensor Resistance/Voltage Chart Temp Resistance* Voltage F Input* Temp Resistance* Voltage F Input* Temp Resistance* Voltage F Input* *Chart Notes: 1. Use the resistance column to check the thermistor sensor while disconnected from the controllers (not powered). 2. Use the voltage column to check sensors while connected to powered controllers. Read voltage with meter set on DC volts. Place the "-"(minus) lead on GND terminal and the "+"(plus) lead on the sensor input terminal being investigated. If the voltage is above 5.08 VDC, then the sensor or wiring is "open." If the voltage is less than 0.05 VDC, the sensor or wiring is shorted. Notes: 1.)The Outside Air Sensor Must Be Mounted In A Vertical Position As Shown (Sensor Tube Pointing Down). Water Must Not Be Allowed To Stand In Sensor Tube. Rainwater Will Damage Sensor. Sensor Must Be Located Where It Will Not Be Affected By Direct Sunlight Or Heat Producing Equipment. If Possible Mount Under Roof Eave Or Similar Protected Location. If Sensor Is Not Located As Specified, Erroneous Outside Air Temperature Readings Will Result. 2.)Unused Conduit Opening(s) Must Have Closure Plugs Installed And Must Be Coated with Sealing Compound To Provide Raintight Seal. Water Can Damage Sensor! 3.)Gasket Must Be Installed Under Cover Plate To Provide Raintight Seal. Rainwater Can Damage Sensor! 4.)All Wiring To Be In Accordance With Local And National Electrical Codes And Specifications. JOB NAME FILENAME G-OE250-OAS-PDWG.CDR DATE: 07/13/15 DRAWN BY: B. CREWS PAGE DESCRIPTION: OE250 1 Outside Air Temperature Sensor

15 OE E-BUS Horizontal Outdoor Air Temperature and Humidity Sensor 2.82 The OE E-BUS Horizontal Outdoor Air Temperature and Humidity is a combination Outdoor Air Temperature and Outdoor Air Humidity sensor that connects to the VCCX2 or VCB-X Controller using an EBC E-BUS modular cable HINGED COVER SENSING TUBE FILTER This sensor is used when both Outdoor Air Temperature and Humidity are needed for the VCCX2 or VCB-X Controller to do Wetbulb or Dewpoint Economizer Control. It is also used if the VCCX2 or VCB-X Controller is used in a Make Up Air application to initiate dehumidification based on an Outdoor Air Dewpoint Setpoint. 3M E-BUS CONNECTOR FEMALE END APPROX. 3M EBC-10F "WATTMASTER EBUS" "WATTMASTER EBUS" EBC-10F M APPROX. E-BUS CONNECTOR EXTENSION CABLE WITH MALE ENDS PROVIDED WITH SENSOR Mounting A 10 foot EBC E-BUS cable (provided) plugs into the E-BUS Outdoor Air Temperature and Humidity Sensor's attached 3 foot cable and then attaches to an E-BUS Expansion port on the VCCX2 or VCB-X Controller or into another available E-BUS Expansion port. The sensor should be mounted in the upright position as shown in an area that is protected from the elements and direct sunlight. CAUTION: Be sure to mount the E-BUS Outdoor Air Temperature & Humidity Sensor in an area that is not exposed to direct sunlight. The shaded area under the HVAC unit rain hood is normally a good location. Unused conduit opening(s) must have closure plugs installed and must be coated with sealing compound to provide a rain-tight seal. Water can damage the sensor. Sensor Element Sensor Reading Range Ambient Temperature Limits Three Year Warranty Digital Capacitive Sensing Device -40 F to 185 F RH = 0-100% OE E-BUS Horizontal Outdoor Air Temperature and Humidity Sensor Accuracy RH +/- 3%, Temp +/-.8 F Connection E-BUS -40 F to 185 F Weight 2.3 oz. AAON reserves the right to change specifications without notice. Form: Orion-OE EBUS-Horiz-OA-RH-Sensor-01C Page 1 of 1

16 OE E-BUS Vertical Outdoor Air Temperature and Humidity Sensor The OE E-BUS Vertical Outdoor Air Temperature and Humidity is a combination Outdoor Air Temperature and Outdoor Air Humidity sensor that connects to the VCCX2 or VCB-X Controller using an EBC E-BUS modular cable FILTER SENSING TUBE 2.35 HINGED COVER 3.29 This sensor is used when both Outdoor Air Temperature and Humidity are needed for the VCCX2 or VCB-X Controller to do Wetbulb or Dewpoint Economizer Control. It is also used if the VCCX2 or VCB-X Controller is used in a Make Up Air application to initiate dehumidification based on an Outdoor Air Dewpoint Setpoint Mounting A 10 foot EBC E-BUS cable (provided) plugs into the E-BUS Outdoor Air Temperature and Humidity Sensor's attached 3 foot cable and then attaches to an E-BUS Expansion port on the VCCX2 or VCB-X Controller or into another available E-BUS Expansion port. The sensor should be mounted in the upright position as shown in an area that is protected from the elements and direct sunlight. 3M M E-BUS CONNECTOR FEMALE END EBC-10F "WATTMASTER EBUS" "WATTMASTER EBUS" EBC-10F APPROX APPROX M E-BUS CONNECTOR EXTENSION CABLE WITH MALE ENDS PROVIDED WITH SENSOR CAUTION: Be sure to mount the E-BUS Outdoor Air Temperature & Humidity Sensor in an area that is not exposed to direct sunlight. The shaded area under the HVAC unit rain hood is normally a good location. Unused conduit opening(s) must have closure plugs installed and must be coated with sealing compound to provide a rain-tight seal. Water can damage the sensor. OE E-BUS Vertical Outdoor Air Temperature and Humidity Sensor Sensor Element Digital Capacitive Sensing Device Accuracy RH +/- 3%, Temp +/-.8 F Sensor Reading Range -40 F to 185 F Connection E-BUS RH = 0-100% Ambient Temperature Limits -40 F to 185 F Weight 2.3 oz. Three Year Warranty AAON reserves the right to change specifications without notice. Form: Orion-OE EBUS-Vert-OA-RH-Sensor-01D Page 1 of 1

17 OE A E-BUS Return Air Temperature and Humidity Sensor 2.82 The OE A E-BUS Return Air Temperature and Humidity is a combination Return Air Temperature and Return Air Humidity sensor that connects to the VCCX2 or VCB-X Controller using an EBC E-BUS modular cable HINGED COVER SENSING TUBE FILTER This sensor is used when both Return Air Temperature and Return Air Humidity are needed for the VCCX2 or VCB-X Controller. The Return Air Humidity Sensor can be used to initiate dehumidification based on an Indoor Humidity Setpoint. E-BUS CONNECTOR FEMALE END APPROX. Mounting A 50 foot EBC E-BUS cable (provided) plugs into the E-BUS Return Air Temperature and Humidity Sensor's attached 3 foot cable and then attaches to an E-BUS Expansion port on the VCCX2 or VCB-X Controller or into another available E-BUS Expansion port. 3M M EBC-10F "WATTMASTER EBUS" "WATTMASTER EBUS" EBC-10F FEET APPROX. E-BUS CONNECTOR EXTENSION CABLE WITH MALE ENDS PROVIDED WITH SENSOR M ALL DIMENSIONS ARE IN INCHES UNLESS OTHERWISE NOTED. Sensor Element Sensor Reading Range Ambient Temperature Limits Three Year Warranty Digital Capacitive Sensing Device -40 F to 185 F RH = 0-100% Accuracy Connection OE A E-BUS Return Air Temperature and Humidity Sensor RH +/- 3%, Temp +/-.8 F E-BUS -40 F to 185 F Weight 2.3 oz. AAON reserves the right to change specifications without notice. Form: ORION-OE A-EBUS-Return-RH-Sensor-01C Page 1 of 1

18 Top View Left Side View Right Side View Front View 6.70 Installation Instructions: 1.) Place The Outside Air Humidity Sensor Where It Is To Be Mounted. See Note 1 Below For Important Mounting Information And Considerations. Mark The (4) Mounting Holes. Secure The Humidity Sensor By Using The (4) #10 X 1.5" Self Tapping Screws Included With The Humidity Sensor. INCORRECT 2.) Open The Cover by Moving the Latch to the Side And Install Your Conduit Connectors. The Cover Must Always Be Opened Before Attempting To Punch Out The Knockouts. 3.) Connect The Wires To The Corresponding Sensor Wire Leads Per The Wiring Diagram On Page 2 Of This Drawing. Insert the Wires Into the Sealant Filled Connectors Provided and Crimp. Lightly Tug on the Wire to Assure a Good Mechanical Connection 4.) Close The Cover by Pushing Down Until the Latch Snaps Into Place. Be Careful Not To Pinch The Sensor Wires When Closing The Housing Cover. 5.) Verify That You Are Getting A Humidity Reading On Your Control System. Please Note That It May Take Ten To Twenty Minutes For The Sensor Reading To Stabilize Upon Initial Power Up. CORRECT Notes: 1.) The Outside Air Humidity Sensor Must Be Mounted In A Vertical Position As Shown (Sensor Tube Pointing Down). Water Must Not Be Allowed To Stand In Sensor Tube, It Will Cause Erroneous Sensor Readings. The Sensor Will Recover When It Dries Out. Sensor Must Be Located Where It Will Not Be Affected By Direct Sunlight Or Heat Producing Equipment. If Possible, Mount Under Roof Eave Or Similar Protected Location. If Sensor Is Not Located As Specified, Erroneous Outside Air Humidity Readings Will Result. 2.) Sensor's Plastic Cover Has A UL94V0 Flame Rating. 3.) Unused Conduit Opening(s) Must Not be Knocked Out to Prevent Dust or Insects From Infiltrating the Sensor Electrical Box. 4.) All Wiring To Be In Accordance With Local And National Electrical Codes And Specifications. INCORRECT Sensor Mounting Position JOB NAME FILE NAME G-OE265-13B-OAHUMID-1G.PDF DATE: 08/13/15 REVISED BY: S. OLSON PAGE DESCRIPTION OE BAPI 1 of 2 Outside Air Humidity Sensor 0-5 VDC

19 0-5 VDC Output Wiring (24VAC Power) CONNECT TO 24 VAC POWER Warning Be Sure To Observe Polarity Or Serious Damage To The Board Could Result 0-5VDC Terminal Label: LB Not Used VACorDC RED GND BLK 0-5V WHT SENSOR TERMINAL BLOCK Humidity Sensor RH/Voltage Chart RH Output % VDC RH Output % VDC *Chart Notes: 1. First, be sure that +24VAC power is being supplied to the sensor. Second check the sensor output. Set the meter to DC volts and connect the meter between ground and the 0-5 VDC input terminal on the controller board or between the 0-5 VDC output on the sensor and its ground wire or you can measure voltage at the 0-5 VDC and GND terminals on the sensor located at the sensor installtion location. After measuring the voltage use an accurate humidity measurement device to determine RH (relative humidity) such as an aspirating psychrometer. Use the Output VDC column to read the Output Voltage corresponding with the RH percentage measured with the psychrometer. If the measured voltage is within 3% of what is listed for the corresponding RH, then the sensor is functioning properly. Notes: 1.) All Wiring To Be In Accordance With Local And National Electrical Codes And Specifications. JOB NAME FILE NAME G-OE265-13B-OAHUMID-1G.PDF DATE: 08/13/15 DRAWN BY: B. CREWS PAGE DESCRIPTION OE BAPI 2 of 2 Outside Air Humidity Sensor 0-5 VDC

20 See Note #1 Mounting Sensor to Duct Top View Left Side View Front View Right Side View Installation Instructions: 1.) Drill a 1" Diameter Hole In The Duct Wall In the Location Where The Humidity Sensor Is To Be Mounted. Insert The Probe Of The Return Air Humidity Sensor Through The Hole. See Note 1 Below For Important Mounting Information And Considerations. Mark The (4) Mounting Holes. Secure The Humidity Sensor By Using The Four #10 X 1.5" Self Tapping Screws Included With The Humidity Sensor. 2.) Open The Cover by Moving the Latch to the Side And Install Your Conduit Connectors. The Cover Must Always Be Opened Before Attempting To Punch Out The Knockouts. 3.) Connect The Wires To The Corresponding Sensor Wire Leads Per The Wiring Diagram On Page 2 Of This Drawing. Insert the Wires Into the Sealant Filled Connectors Provided and Crimp. Lightly Tug on the Wire to Assure a Good Mechanical Connection 4.) Close The Cover by Pushing Down Until the Latch Snaps Into Place. Be Careful Not To Pinch The Sensor Wires When Closing The Housing Cover. 5.) Verify That You Are Getting A Humidity Reading On Your Control System. Please Note That It May Take Ten To Twenty Minutes For The Sensor Reading To Stabilize Upon Initial Power Up. Notes: 1.) The Sensor Should Be Mounted so that the 6" Probe is in the Center of the Return Air Duct. It Should be Mounted Away from Fans, Elbows, Heating or Cooling Coils or Other Equipment that Could Affect the Measurement of Relative Humidity. Also, the Sensor Should be Mounted in an Area that Receives Adequate Air Flow for Proper Operation. The Sensor may be Mounted Horizontally or Vertically to the Return Air Duct. See the Sensor Mounting Diagram Above. 2.) Unused Conduit Opening(s) Must Not be Knocked Out to Prevent Dust or Insects From Infiltrating the Sensor Electrical Box. 3.) The Sensor Probe Gasket Must Be Installed Between the Back of the Sensor Box and the Duct to Provide an Airtight Seal. 4.) All Wiring To Be In Accordance With Local And National Electrical Codes And Specifications. JOB NAME FILE NAME G-OE265-14B-RAHUMID-1D.PDF DATE: 08/28/07 PAGE 1 of 2 DRAWN BY: B. CREWS DESCRIPTION OE BAPI Return Air Humidity Sensor 0-5 VDC

21 0-5 VDC Output Wiring (24 VAC Power) CONNECT TO 24 VAC POWER Warning Be Sure To Observe Polarity Or Serious Damage To The Unit Could Result 0-5VDC Terminal Label: LB Not Used VACorDC RED GND BLK 0-5V WHT SENSOR TERMINAL BLOCK Humidity Sensor RH/Voltage Chart RH Output % VDC RH Output % VDC *Chart Notes: 1. First, be sure that +24VAC power is being supplied to the sensor. Second check the sensor output. Set the meter to DC volts and connect the meter between ground and the 0-5 VDC input terminal on the controller board or between the 0-5 VDC output on the sensor and its ground wire or you can measure voltage at the 0-5 VDC and GND terminals on the sensor located at the sensor installtion location. After measuring the voltage use an accurate humidity measurement device to determine RH (relative humidity) such as an aspirating psychrometer. Use the Output VDC column to read the Output Voltage corresponding with the RH percentage measured with the psychrometer. If the measured voltage is within 3% of what is listed for the corresponding RH, then the sensor is functioning properly. Notes: 1.) All Wiring To Be In Accordance With Local And National Electrical Codes And Specifications. JOB NAME FILE NAME G-OE265-14B-RAHUMID-1D.PDF DATE: 08/28/07 DRAWN BY: B. CREWS PAGE DESCRIPTION OE BAPI 2 of 2 Return Air Humidity Sensor 0-5 VDC

22 Front View Right Side View Installation Instructions: 1.) Place The SpaceHumidity Sensor Where It Is To Be Mounted. See Note 1 Below For Important Mounting Information And Considera tions. 2.) Remove The Humidity Sensor Cover By Screwing In The 2 Allen Screws That Secure It To The Base. 3.) Connect All Of The Wires From The Controller Board To The Corresponding Terminal Blocks Per The Wiring Diagram On Page 2 OfThis Drawing. 4.) Secure The Cover Onto The Base Housing By Snapping The Cover Onto The Base And Backing Out The 2 Allen Screws. 5.) Verify That You Are Getting A Humidity Reading On Your Control System. Please Note That It May Take Ten To Twenty MinutesFor The Sensor Reading To Stabilize Upon Initial Power Up. Notes: 1.) The sensor is designed to be wall mounted in rooms where appearance is important. It may be mounted directly on dry wall or on any single gang electrical outlet box with no adapters required. Toggle bolts or other direct wall mount screws can be used where conduit is not required. It includes a detachable mounting plate. The cover is secured with tamper-resistant hex screws. The sensor should be mounted approximately five feet above the floor, on an interior wall, away from any heating or cooling generating devices, and out of the sun. Plug the wireway hole to prevent false readings by air drafts within the wall. 2.) Sensor s Plastic Cover Has A UL94V0 Flame Rating. 3.) All Wiring To Be In Accordance With Local And National Electrical Codes And Specifications. JOB NAME DATE: 08/13/15 REVISED BY: S. OLSON FILE NAME G-OE SPHUMID-1F.PDF DATE: 08/10/15 PAGE 1 of 2 DRAWN BY: B. CREWS DESCRIPTION OE Space Humidity Sensor 0-5 VDC

23 0-5VDC Terminal Label: LB Not Used Not Used Vo Vin Gnd NOTE: RESISTOR IS NOT REQUIRED FOR CONTROLLERS 24 VAC or VDCTHAT HAVE JUMPER SELECTABLE ANALOG INPUTS. TB3 ANALOG INPUTS AI1 0-5v 0-10v AI ma THERM CONNECT TO SPECIFIED AIx TERMINAL FOR YOUR APPLICATION. SEE SPECIFIC WIRING DIAGRAM FOR YOUR APPLICATION THE PULL-UP RESISTOR FOR CORRECT (PUx) FOR THE ASSOCIATED ANALOG AIX TERMINAL TO BE USED. INPUT MUST BE REMOVED FROM THE CONTROLLER BOARD FOR THE SENSOR TO OPERATE JUMPER SELECTABLE STYLE CONTROLLER TERMINAL. SET FOR 0-5V. GND NOTE: RESISTOR IS REQUIRED FOR CONTROLLERS THAT DO NOT HAVE JUMPER SELECTABLE ANALOG INPUTS. GND CONNECT TO GROUND TERMINAL FOR YOUR ANALOG INPUT(S). Humidity Sensor RH/Voltage Chart RH Output % VDC RH Output % VDC Chart Notes 1.) First be sure that the +24 VAC power is being supplied to the sensor. Second set the meter to DC volts and connect the meter between ground and the 0-5 VDC input on the controller board or between the 0-5 VDC output terminal on the sensor and its ground terminal. Use an accurate humidity measurement device (such as an aspirating psychrometer) to determine the RH percentage (relative humidity). Use the Output VDC column on the chart to read the voltage corresponding with the RH percentage column just measured. If the measured voltage is within 3% of what is listed for the corresponding RH, the sensor is functioning correctly. If it is not you will need to replace the sensor. JOB NAME FILENAME G-OE SPHUMID-1F.CDR Notes: 1.) All Wiring To Be In Accordance With Local And National Electrical Codes And Specifications. DATE: 08/13/15 DRAWN BY: B. CREWS PAGE DESCRIPTION: OE of 2 Wall Mounted Humidity Sensor VDC

24 OE EBSE E-BUS SPACE TEMP/HUMIDITY SENSOR EMULATION BOARD OE EBSE E-BUS Space Temp/RH Sensor Emulator Board 4.2±0.15 The OE EBSE E-BUS Space Temperature and Humidity Sensor Emulator Board allows the use of separate 3 rd party space temperature and humidity sensors to emulate the WattMaster E-BUS combination Space Temperature and Humidity Sensor The board provides E-BUS-out communication to these unit controllers or to their attached E-BUS modules using the supplied 1.5 foot EBC E-BUS cable. Both the temperature and humidity sensors must be wired into this Emulator Board. The Emulator Board converts the analog signals to E-BUS. 1.5 Foot EBC E-BUS Cable The normal Space sensor override and slide adjust functions are not available when using the Emulator Board. The Emulator Board has 2 EBC E-BUS connectors, allowing it to also act as an adapter board. One port can be used to connect the Emulator Board to the controller. The other port can be used to connect to another sensor or controller. The E-BUS Sensor Emulator Board has 3 LEDs COMM LED to indicate sensor communication to the board, POWER LED to indicate that the board is powered up, and ALARM to indicate an alarm condition. OE EBSE E-BUS Space Temperature and Humidity Sensor Emulator Board Maximum Power Consumption 250 ma Operating Temperature -20ºF to 150ºF Idle Current* <5 ma Humidity Sensor Input Terminations Transmit Current* ~100 ma Temperature Sensor Input Termination 0-5 VDC 0-10 VDC 10K Ohm Type III Thermistor Module Weight without Cable 1.92 oz. Output Terminations (2) EBC E-BUS Connections +5VDC Module Weight with EBC-1.5F Cable Three Year Warranty 2.64 oz. *NOTE: Currents may vary depending on the attached sensing elements. WattMaster reserves the right to change specifications without notice Form: ORION-OE EBSE-SpcRH-1A.doc Page 1 of 1

25 OE EBSE E-BUS RETURN AIR TEMP/HUMIDITY SENSOR EMULATION BOARD OE EBSE E-BUS Return Air Temp/RH Sensor Emulator Board 4.2±0.15 The OE EBSE E-BUS Return Air Temperature and Humidity Sensor Emulator Board allows the use of 3 rd party analog return air temperature and humidity sensors to emulate the WattMaster E-BUS combination Return Air Temperature and Humidity Sensor The E-BUS Emulator Board works with the VCC-X and VCB-X Controllers. The board provides E-BUS-out communication to these unit controllers or to their attached E-BUS modules using the supplied 1.5 foot EBC E-BUS cable. Both the temperature and humidity sensors must be wired into this Emulator Board. The Emulator Board converts the analog signals to E-BUS. 1.5 Foot EBC E-BUS Cable The Emulator Board has 2 EBC E-BUS connectors, allowing it to also act as an adapter board. One port can be used to connect the Emulator Board to the controller. The other port can be used to connect to another sensor or controller. The E-BUS Sensor Emulator Board has 3 LEDs COMM LED to indicate sensor communication to the board, POWER LED to indicate that the board is powered up, and ALARM to indicate an alarm condition. OE EBSE E-BUS Return Air Temperature and Humidity Sensor Emulator Board Maximum Power Consumption 250 ma Operating Temperature -20ºF to 150ºF Idle Current* <5 ma Humidity Sensor Input Terminations Transmit Current* ~100 ma Temperature Sensor Input Termination 0-5 VDC 0-10 VDC 10K Ohm Type III Thermistor Module Weight without Cable 1.92 oz. Output Terminations (2) EBC E-BUS Connections +5VDC Module Weight with EBC-1.5F Cable Three Year Warranty 2.64 oz. *NOTE: Currents may vary depending on the attached sensing elements. WattMaster reserves the right to change specifications without notice Form: ORION-OE EBSE-RATRH-1A.doc Page 1 of 1

26 OE EBSE E-BUS OUTDOOR AIR TEMP/HUMIDITY SENSOR EMULATION BOARD OE EBSE E-BUS Outdoor Air Temp/RH Sensor Emulator Board 4.2±0.15 The OE EBSE E-BUS Outdoor Air Temperature and Humidity Sensor Emulator Board allows the use of 3 rd party analog outdoor air temperature and humidity sensors to emulate the WattMaster E-BUS combination Outdoor Air Temperature and Humidity Sensor The E-BUS Emulator Board works with the VCC-X and VCB-X Controllers. The board provides E-BUS-out communication to these unit controllers or to their attached E-BUS modules using the supplied 1.5 foot EBC E-BUS cable. Both the temperature and humidity sensors must be wired into this Emulator Board. The Emulator Board converts the analog signals to E-BUS. 1.5 Foot EBC E-BUS Cable The Emulator Board has 2 EBC E-BUS connectors, allowing it to also act as an adapter board. One port can be used to connect the Emulator Board to the controller. The other port can be used to connect to another sensor or controller. The E-BUS Sensor Emulator Board has 3 LEDs COMM LED to indicate sensor communication to the board, POWER LED to indicate that the board is powered up, and ALARM to indicate an alarm condition. OE EBSE E-BUS Outdoor Air Temperature and Humidity Sensor Emulator Board Maximum Power Consumption 250 ma Operating Temperature -20ºF to 150ºF Idle Current* <5 ma Humidity Sensor Input Terminations Transmit Current* ~100 ma Temperature Sensor Input Termination 0-5 VDC 0-10 VDC 10K Ohm Type III Thermistor Module Weight without Cable 1.92 oz. Output Terminations (2) EBC E-BUS Connections +5VDC Module Weight with EBC-1.5F Cable Three Year Warranty 2.64 oz. *NOTE: Currents may vary depending on the attached sensing elements. WattMaster reserves the right to change specifications without notice Form: ORION-OE EBSE-OATRH-1A.doc Page 1 of 1

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide

Factory Packaged Controls. OE (AAON Part No. V12090) MODGAS-X Controller Field Technical Guide Factory Packaged Controls OE377-26-00058 (AAON Part No. V12090) MODGAS-X Controller Table of Contents GENERAL INFORMATION... 3 Overview...3 Features...3 INSTALLATION & WIRING... 4 Supply Air Temperature

More information

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series) Overview The BAPI-Stat 4 Style room unit is available as a humidity only sensor or as a combination temperature and humidity sensor with optional LCD display, temperature setpoint adjustment and occupant

More information

BAPI-Stat 3 Room Sensor

BAPI-Stat 3 Room Sensor Overview and Identification The BAPI-Stat 3 is a multiple output transmitter for temperature and humidity with setpoint capability for both and occupied/unoccupied override switching. The large easy-to-read

More information

OE326-23I-OR VAV/Zone Controller

OE326-23I-OR VAV/Zone Controller + 4 8 - Description The OE36-3I-OR is a that is designed for pressure independent VAV Box and Zone Damper applications. It is supplied with an integral Airflow Sensor and is mounted in a plastic enclosure.

More information

Description. functions including single duct pressure dependent or pressure independent systems.

Description. functions including single duct pressure dependent or pressure independent systems. Description The Meridian Basic control system converts a single zone HVAC unit into a variable air volume/variable air temperature multiple zone system. The microprocessor based Zone Manager calculates

More information

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration

CO 2 Room Sensor in the BAPI-Stat 3 Enclosure with Common Ground Configuration Identification and Overview The BAPI CO 2 Sensor is an accurate and reliable way of incorporating demand controlled ventilation into a building s HVAC strategy. It measures the CO 2 in a range of 0 to

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION MERIDIAN PLUS CONTENTS TIPS BEFORE BEGINNING INSTALLATION......... 2 ZONEMANAGER...3 ZONE MANAGER ADDRESSING.................. 5 COMMUNICATIONSLOOPS...6 COMMUNICATIONS LOOP WIRING

More information

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and slider setpoint adjustment. Additional options include button override and communication

More information

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control Product Identification and Overview The BAPI-Stat Quantum style room temperature sensor features a large format LCD and pushbutton setpoint adjustment. Additional options include pushbutton override, fan

More information

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions Product Identification Fig 1. BAPI-Com Communication Output Module Fig 2. BAPI-Com Room Sensor, BA/BS4SCOM Operations Overview The BAPI-Com sensor is designed to be used in retrofit applications on just

More information

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor Product Identification and Overview Power and Communication on Just Two Wires Available with Temperature Sensing, Temperature Setpoint, Optional Occupant Override, Optional Display and Optional %RH Sensing

More information

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure

CO 2 Room Sensor in the BAPI-Stat Quantum Prime Style Enclosure Identification and Overview The BAPI CO 2 Sensor is an accurate and reliable way of incorporating demand controlled ventilation into a building s HVAC strategy. It measures the CO 2 in a range of 0 to

More information

AD592/592-10K Non-Room Units with a Junction Box, Weatherproof (WP) or Weather Tight (EU) Enclosure

AD592/592-10K Non-Room Units with a Junction Box, Weatherproof (WP) or Weather Tight (EU) Enclosure 592 Theory of Operation The 592 sensor is a two terminal integrated-circuit temperature sensor. The 592 provides an output current directly proportional to absolute temperature. When the temperature of

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION SIG DET RDY SND REC PWR INSTALLATION INSTRUCTION MERIDIAN BASIC CONTENTS Fan H E A T I N G C O O L I N G F IL T E R Mixed Air Outside Air Exhaust Air TIPS BEFORE BEGINNING INSTALLATION......... 2 ZONEMANAGER...2

More information

VOC Duct and Rough Service Sensor

VOC Duct and Rough Service Sensor Overview and Identification Humans respirate Volatile Organic Compounds (VOCs) as well as CO 2. The BAPI sensor measures these VOCs and indicates space occupancy just as well as a CO 2 sensor. The advantage

More information

SEN and SEN Outdoor Air Temperature Sensors

SEN and SEN Outdoor Air Temperature Sensors FANs 216, 1628.3 Product/Technical Bulletin SEN-500-2, SEN-500-3 Issue Date 0996 SEN-500-2 and SEN-500-3 Outdoor Air Temperature Sensors The SEN-500-2 and SEN-500-3 Outdoor Air Temperature Sensors offer

More information

YCCS TE-6800 Series Temperature Sensors

YCCS TE-6800 Series Temperature Sensors YCCS TE-6800 Series Temperature Sensors TE-68xx-xNN0S Installation Instructions 85-YIM-B-070 Applications The York Commercial Comfort System (YCCS) TE-68xx-xNN0S Series Temperature Sensors provide temperature

More information

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Blank-off. HVAC unit screws. Spacer for 1 filter ILL. 3. Screw ICP INSTALLATION INSTRUCTIONS for NPECOMZR00A00 ICP's economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully

More information

VOC Room Sensor in the BAPI-Stat 3 Enclosure with Differential Ground Configuration

VOC Room Sensor in the BAPI-Stat 3 Enclosure with Differential Ground Configuration Identification and Overview Humans exhale Volatile Organic Compounds (VOCs) as well as CO2. The BAPI sensor is able to measure these VOCs, therefore it is as good an indicator of space occupancy as a CO2

More information

Temperature Transmitters

Temperature Transmitters Termination BAPI recommends using twisted pair of at least 22AWG and sealant filled connectors for all wire connections. Larger gauge wire may be required for long runs. All wiring must comply with the

More information

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1 filter ILL. 3. Screw ICP INSTALLATION INSTRUCTIONS for (NPECOMZR006A00) ICP's economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully

More information

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1 filter ILL. 3. Screw MicroMetl INSTALLATION INSTRUCTIONS for 0637-0311 (CPECOMZR006A00) MicroMetl's 0637 economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions

More information

MicroTech III Water Source Heat Pump Wall-Mounted Room Temperature Sensors

MicroTech III Water Source Heat Pump Wall-Mounted Room Temperature Sensors Installation & Maintenance Data IM 955-1 Group: WSHP Part Number: 668997001 Date: June 2010 MicroTech III Water Source Heat Pump Wall-Mounted Room Temperature Sensors Sensor Kit P/N 669529001, 669529101

More information

TS Series TS Series

TS Series TS Series TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com TS-6700-850 Series TS-5700-850 Series Electronic Remote Temperature Sensors General Instructions APPLICATION Electronic thermistor

More information

GE Measurement & Control

GE Measurement & Control GE Measurement & Control Telaire Ventostat 8000 Series CO 2 Sensor User Instructions Installing the Sensor!WARNING! Before performing service or maintenance operations on the systems, turn OFF main power

More information

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE: ACCUVALVE MODEL AVC6000 SUBMITTAL MODEL CODE WARNING: NOT FOR USE WITH PERCHLORIC ACID MATERIALS VALVE HOUSING MATERIAL 2 = 304SS, 20 GAUGE 3 = 316SS, 20 GAUGE 4 = ALUMINUM, 16 GAUGE 6 = HIGH TEMP 304SS,

More information

THC-2, THC-3, THCR-4, THCR-5. Enthalpy Control. General Instructions APPLICATION SPECIFICATIONS. ACCESSORIES None

THC-2, THC-3, THCR-4, THCR-5. Enthalpy Control. General Instructions APPLICATION SPECIFICATIONS. ACCESSORIES None THC-2, THC-3, THCR-4, THCR-5 Enthalpy Control General Instructions APPLICATION For ON-OFF (two position) low voltage control of the amount of air brought into the cooling system with respect to the total

More information

DPS/MPS/RAH/RPS/SWP Space Sensor

DPS/MPS/RAH/RPS/SWP Space Sensor Installation Manual IM 1199 DPS/MPS/RAH/RPS/SWP Space Sensor Group: Applied Air Part Number: IM 1199 Date: May 2013 2013 Daikin Applied Table of Contents Introduction.... 2 Installation.... 3 Mounting...

More information

General Description. Product Specification. Document Digital Temperature Interlock

General Description. Product Specification. Document Digital Temperature Interlock Document 474751 Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the

More information

INSTALLATION MANUAL. Melink Corporation (513) Revision

INSTALLATION MANUAL. Melink Corporation (513) Revision INSTALLATION MANUAL Revision 130711 Table of Contents Step Installation Contractor Page 1 Install System Controller Electrical 4 2 Install Variable Frequency Drive Electrical 6 3 Install Touchpad Mechanical

More information

RSMD Technical Guide

RSMD Technical Guide RSMD Technical Guide TABLE OF CONTENTS OVERVIEW... 4 Features and Applications... 4 Module Dimensions... 5 INSTALLATION & WIRING... 6 Input Wiring... 6 Suction Pressure Sensor... 6 Head Pressure Sensor...

More information

AD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation

AD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation 592 Theory of Operation The 592 sensor is a two terminal integrated-circuit temperature sensor. The 592 provides an output current directly proportional to absolute temperature. When the temperature of

More information

System 350 P352AB Electronic Pressure Control Series

System 350 P352AB Electronic Pressure Control Series System 350 P352AB Electronic Pressure Control Series System 350 Product Guide 930 Basic Controls Section Product/Technical Bulletin P352AB Issue Date 0200 The P352AB controls are On/Off electronic pressure

More information

Compact Low Pressure Sensor

Compact Low Pressure Sensor Overview The Low Pressure Sensor is a true differential pressure transmitter that provides ±1 inches WC (±250 Pacals) in 10 field selectable ranges (see specifications). The enclosure is designed for DIN

More information

QUICK START GUIDE VAV CONTROLLERS & WALL SENSORS rue Charles, Suite 100, Mirabel, QC, J7J 1X9

QUICK START GUIDE VAV CONTROLLERS & WALL SENSORS rue Charles, Suite 100, Mirabel, QC, J7J 1X9 QUICK START GUIDE VAV CONTROLLERS & WALL SENSORS www.proloncontrols.com info@proloncontrols.com 17 510 rue Charles, Suite 100, Mirabel, QC, J7J 1X9 REV 1.0 PL-QCK-WSENSOR/VC2000-EN Copyright 2018 Prolon.

More information

Duct Averaging Transmitters BA/T#-A Temperature Transmitter Installation & Operations

Duct Averaging Transmitters BA/T#-A Temperature Transmitter Installation & Operations Overview The BA/T#-A is a flexible averaging duct mounted 4-20mA or Voltage transmitter probe. It comes in a variety of probe lengths and optional mounting enclosures shown below. The 4-20mA transmitter

More information

TS , -850 Series TS , -850 Series TS-57031, TS

TS , -850 Series TS , -850 Series TS-57031, TS TS-5711-770, -850 Series TS-57011-770, -850 Series TS-57031, TS-57031-850 Electronic Room Temperature Sensors General Instructions Application These sensors provide electronic sensing of room temperature

More information

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH TGDFC-6 DFC Direct Fired Gas Heating System Technical Guide for: Outdoor Mounted Units To 0,000 CFM And 14M BTUH Applied Air Keeps You Warm Featuring the Patented AdaptAire controlled Circulation System

More information

Digital Room Thermostats with Touch Screen LCD

Digital Room Thermostats with Touch Screen LCD TC40 Touch Series Digital Room Thermostats with Touch Screen LCD Revision Date February 22, 2013 Features Wall-mount Display Control to match any decor Extra large easy-to-read Liquid Crystal Display (LCD),

More information

Safety & Installation Instructions

Safety & Installation Instructions Model 8120A & 8126A Digital Ventilation Controller Safety & Installation Instructions READ AND SAVE THESE INSTRUCTIONS Table of contents Safety Instructions... 3 Specifications... 4 Overview... 4 Mounting

More information

1' to 10' deep and 1' to 25' deep

1' to 10' deep and 1' to 25' deep ULTRASONIC ECHO-SCALE TM SCALE: INDICATOR: ECHO-SCALE TM NONE PROVIDED electronic sensors for vessels 1' to 10' deep and 1' to 25' deep INSTALLATION & OPERATION s/n 1-800-893-6723 Fax: 925-686-6713 www.forceflow.com

More information

MA-5200 Series MA-5300 Series

MA-5200 Series MA-5300 Series MA-5200 Series MA-5300 Series Two-Position Actuators General Instructions Application The MA-5200 series and MA-5300 series actuators are used for two-position control of valves and dampers which require

More information

Submersible Averaging Duct Transmitters BA/T#SA Temperature Transmitter Installation & Operations

Submersible Averaging Duct Transmitters BA/T#SA Temperature Transmitter Installation & Operations Overview The BA/#-SA is for duct mounting 4 to 20mA or Voltage temperature transmitter for measurement of moisture saturated, stratified air across a duct with a humidifier or outside air intake to give

More information

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions CP-80-xxx Series to 5 Vdc Input Electronic General Instructions Application The CP-80-xxx Series electronic actuator drive is designed to process a variable to 5 Vdc signal from a controller to provide

More information

Metasys Zoning Package Installation

Metasys Zoning Package Installation Technical Bulletin Issue Date August 28, 2002 Metasys Zoning Package Installation Metasys Zoning Package Installation...2 Introduction... 2 Key Concepts... 3 Installation Overview... 3 Metasys Zoning Package

More information

Installation/ Operation Maintenance. VariTrac Dampers

Installation/ Operation Maintenance. VariTrac Dampers Installation/ Operation Maintenance VariTrac Dampers June 2002 General These instructions do not cover all variations in systems nor provide for every possible contingency that may arise at a jobsite installation.

More information

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A Automation, Inc. Model EAC1100 /A QUICK INSTALL GUIDE Advanced Outdoor Airflow Control, DCV Control and Alarm Solution Enhancer QUICK INSTALL GUIDE for ENHANCER Advanced Outdoor Airflow Control, DCV Control

More information

Package Unit Modulating Economizer Installation Instructions

Package Unit Modulating Economizer Installation Instructions Package Unit Modulating Economizer Installation Instructions Downflow Unit Warning: Recognize this symbol as an indication of Important Safety Information! Read all instructions prior to installation.

More information

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012 COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES 506953-01 3/2014 Supersedes 8/2012 Litho U.S.A. MSAV Supply Air Blower VFD Kit INSTALLATION INSTRUCTIONS FOR MSAV (MULTI-STAGE AIR VOLUME) SUPPLY AIR BLOWER

More information

I-BFV.KIT Butterfly Valve Gear Operator Replacement

I-BFV.KIT Butterfly Valve Gear Operator Replacement SERIES 5, 05,, and 0C WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before

More information

2520- EC Motor Speed Controller

2520- EC Motor Speed Controller 2520- EC Motor Speed Controller T1 AC Line Voltage From Contactor T2 or Neutral 760-ECM ECM Motor BLACK ORANGE BLACK RED (+) Signal 24VAC (-) GND Features Motor Types: ECM (dc brushless) Motors Motor Speed:

More information

ECONOMIZERS. 5/2012 Supersedes

ECONOMIZERS. 5/2012 Supersedes Litho U.S.A. 2012 ECONOMIZERS 507031 01 5/2012 Supersedes 506747 01 K1ECON ECONOMIZERS INSTALLATION INSTRUCTIONS FOR ECONOMIZERS AND OUTDOOR AIR HOODS USED WITH KG/KC/KH 024, 030, 036, 048, 060, 072, 090

More information

System 350 S350P Proportional Plus Integral Temperature Stage Module

System 350 S350P Proportional Plus Integral Temperature Stage Module FANs 930, 930.5 Add-On Modules Section Product/Technical Bulletin S350P Issue Date 0997 System 350 S350P Proportional Plus Integral Temperature Stage Module The S350P is used in conjunction with the A350

More information

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN Hardware Installation Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN Hardware Installation Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN February 2004 CNT-SVN02B-EN Tracer AH541

More information

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18 Zone Sensors Submittal Data English Language/IP Units SD1582EW 06/18 ZS Series RNet Zone Sensors ZS Series RNet Sensor Overview The ZS Series line of intelligent zone sensors provides the function and

More information

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER INSTALLATION INSTRUCTIONS WARNING: The Model 8682 Adaptive Offset Controller must be wired to 24 VAC only. Wiring the unit to 110 VAC will cause serious unit

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS MiniCOREVentilator ENERGY RECOVERY CORE INSTALLATION INSTRUCTIONS MC500-1ERV JANUARY 10, 2018 SUPERSEDES: NONE INSTALLATION INSTRUCTIONS FOR MINICORE VENTILATOR (MCV) WITH FACTORY INSTALLED OPTIONS USED

More information

OPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4)

OPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4) MOEL COE UCT SHAPE = Round = Rectangular = Flat Oval PROBE MATERIAL = Aluminum/ABS = CPVC & ABS = 0SS = High Temp SS (50 F / C Max) PROBE QUANTITY = = s = s = s SENSORS PER PROBE = Sensor per = Sensors

More information

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions CP-90 CP-90 Electronic Drives General Instructions Application The CP-90 and CP-90 electronic actuator drives process a variable input signal from a controller to provide proportional control of an electric

More information

Installation, Start-Up and Configuration Instructions

Installation, Start-Up and Configuration Instructions 3V Control System VVT Zone Controller Pressure Dependent Control Installation, Start-Up and Configuration Instructions Part Number 33ZCVVTZC-01 CONTENTS Page SAFETY CONSIDERATIONS...1 GENERAL...2 INSTALLATION...

More information

SolarSheat Wall Installation Manual

SolarSheat Wall Installation Manual SolarSheat Wall Installation Manual Version 3.2 December 15, 2015 Copyright 2015 Your Solar Home, All Rights Reserved SolarSheat products must be installed in accordance to all local building, plumbing,

More information

ComfortPoint Programmable Lon, VAV/Unitary Controllers

ComfortPoint Programmable Lon, VAV/Unitary Controllers ComfortPoint Programmable Lon, VAV/Unitary Controllers Controller Model Programmable Type Universal Inputs (UI) Table 1. Controller configurations. Digital Inputs (DI) PRODUCT DESCRIPTION INSTALLATION

More information

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14 Zone Sensors Submittal Data English Language/IP Units SD1582EW 10/14 ZS Series RNet Zone Sensors ZS Series RNet Sensor Overview The ZS Series line of intelligent zone sensors provides the function and

More information

Combined Ventilation Controller RVWS-T-224HA

Combined Ventilation Controller RVWS-T-224HA Combined Ventilation Controller RVWS-T-224HA 8-stage Control for Power/Natural Applications 2 variable speed stages, 2 curtain winch stages, 2 fixed speed ventilation stages, 1 thermo/mister cycle stage

More information

Package Unit Modulating Economizer Installation Instructions

Package Unit Modulating Economizer Installation Instructions Package Unit Modulating Economizer Installation Instructions Downflow Unit Warning: Recognize this symbol as an indication of Important Safety Information! Read all instructions prior to installation.

More information

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT Supersedes Form145.10-IOM1 (810) Form 145.10-IOM1 (910) LOW-AMBIENT KIT MODELS DSH/KSH/DSV/KSV R-410A AIR CONDITIONING UNITS INSTALLATION INSTRUCTIONS IMPORTANT!

More information

CP (Vdc) CP (Milliamp) CP (Slidewire)

CP (Vdc) CP (Milliamp) CP (Slidewire) CP-91-456 (Vdc) CP-91-716 (Milliamp) CP-91-717 (Slidewire) Electronic General Instructions Application Electronic actuator drive is used to provide proportional control of an electric gear train actuator

More information

Table of Contents. Carrier Sensors

Table of Contents. Carrier Sensors Carrier Sensors Installation Guide CARRIER CORPORATION 2011 A member of the United Technologies Corporation family Stock symbol UTX Catalog No. 11-808-423-01 3/13/2012 Table of Contents Introduction to

More information

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment

More information

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit Instruction Sheet 10-2004 Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit 541 0811 PURPOSE OF KIT A CCM-T is used to monitor and control an automatic transfer switch.

More information

Spyder BACnet Programmable Controllers

Spyder BACnet Programmable Controllers Spyder BACnet Programmable Controllers Controller Model Programmable Type Table 1. Controller configurations. INSTALLATION INSTRUCTIONS PRODUCT DESCRIPTION The PUB and PVB controllers are part of the Spyder

More information

ACCUVALVE MODEL AVT6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVT6000 AVT6 - - DWG. NO: REVISION: REV. DATE:

ACCUVALVE MODEL AVT6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVT6000 AVT6 - - DWG. NO: REVISION: REV. DATE: ACCUVALVE MODEL AVT6000 SUBMITTAL MODEL CODE WARNING: NOT FOR USE WITH PERCHLORIC ACID MATERIALS VALVE HOUSING MATERIAL 2 = 304SS, 20 GAUGE 3 = 316SS, 20 GAUGE 4 = ALUMINUM, 16 GAUGE 6 = HIGH TEMP 304SS,

More information

Temperature Sensors. NTC Thermistors. Descriptions. RTS-Raw 10K NTC Thermistor. Specifications: Dimensions (mm):

Temperature Sensors. NTC Thermistors. Descriptions. RTS-Raw 10K NTC Thermistor. Specifications: Dimensions (mm): NTC Thermistors Descriptions In many industrial sectors and fields of research, temperature is one of the most important parameters which decides about product quality, security, and reliability. Temperature

More information

MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER

MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER MODEL RPC30 (-LON) PRESSURA ROOM PRESSURE CONTROLLER INSTALLATION INSTRUCTIONS WARNING The Model RPC30 (-LON) Room Pressure Controller must be wired to 24 VAC only. Wiring the unit to 110 VAC will cause

More information

TM-9100 Series Room Command Module

TM-9100 Series Room Command Module FANs 216, 1628.3 Product/Technical Bulletin TM-9100 Issue Date 0400 TM-9100 Series Room Command Module The TM-9100 Series Room Command Modules are designed for use with the TC-9100 series of DDC (Direct

More information

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories

MX4X-6XXX Series MX4X-7XXX Series. Selection Guide. Applications. DuraDrive Series Actuators and Accessories MX4X-6XXX Series MX4X-7XXX Series Selection Guide DuraDrive Series Actuators and Accessories Applications DuraDrive Direct Coupled Actuators are designed to accept two-position, floating, or proportional

More information

Series 1000 Room Temperature Sensors, 1K Ω Platinum (375α) RTD (MBC/RBC/MEC/UC)

Series 1000 Room Temperature Sensors, 1K Ω Platinum (375α) RTD (MBC/RBC/MEC/UC) Document No. 540-743 Series 1000 Room Temperature Sensors, 1K Ω Platinum (375α) RTD (MBC/RBC/MEC/UC) Product Description These sensors work with the Modular Building Controller (MBC), Remote Building Controller

More information

ECONOMIZERS. 1/2012 Supersedes

ECONOMIZERS. 1/2012 Supersedes ECONOMIZERS Litho U.S.A. 2012 506948 01 1/2012 Supersedes 506394 01 K1ECON20C 1 ECONOMIZERS INSTALLATION INSTRUCTIONS FOR ECONOMIZER AND OUTDOOR AIR (604592 03; 54W77) USED WITH KG/KC/KH 180 300S UNITS

More information

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-8 Features: ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS Filtered/Regulated 24 Volts DC Up to Full 2 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit

More information

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

M9106-AGx-2N0x Series Electric Non-spring Return Actuators Installation Instructions M9106AGx-2N0x Issue Date 08/31/01 M9106-AGx-2N0x Series Electric Non-spring Return Actuators Installation IMPORTANT: The M9106-AGx-2N0x Series actuator is intended to control

More information

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE 5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE MODEL# 505 ( AMP @ VDC OR 4VDC) MODEL# 5500 ( AMP @ VDC OR AMPS @ 4VDC) MODEL# 5600- (0 AMPS @ VDC) MODEL# 5600-4 (5 AMPS @ 4VDC) IMPORTANT SAFETY INSTRUCTIONS

More information

MS Application. Features. Proportional Valve Actuator General Instructions

MS Application. Features. Proportional Valve Actuator General Instructions Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and

More information

ELECTRICAL INSTALLATION PROCEDURES For Custom Grid Assemblies & Power Generators

ELECTRICAL INSTALLATION PROCEDURES For Custom Grid Assemblies & Power Generators ELECTRICAL INSTALLATION PROCEDURES For Custom Grid Assemblies & Power Generators BECAUSE CLEAN AIR MATTERS Note: Factory trained or suitably qualified personnel must perform this installation. General:

More information

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output TCAF Series Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output Issue Date March 1, 2018 Features Ultra slim wall-mount unit to match any décor Large easy-to-read Liquid Crystal Display (LCD), with

More information

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies Installation Instructions Part No. 24-4034-42, Rev. D Issued December 9, 2011 Supersedes August 1, 1997 Applications TE-6100

More information

RA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System

RA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System RA-1250 Thermal Dispersion Fan Inlet Sensors Airflow Measuring System Product Bulletin Code No. LIT-12011620 Issued July 2, 2014 RA-1250 Thermal Dispersion Fan Inlet Sensor Airflow Measuring System averages

More information

ASSEMBLY INSTRUCTIONS ZONE MODULE 2 1 THERMOSTAT DESCRIPTION POWER SUPPLY AIRZONE CONTROLLER

ASSEMBLY INSTRUCTIONS ZONE MODULE 2 1 THERMOSTAT DESCRIPTION POWER SUPPLY AIRZONE CONTROLLER ZONE MODULE 2 1 ASSEMBLY INSTRUCTIONS AIRZONE CONTROLLER THERMOSTAT DESCRIPTION The Touch Thermostat, is the access panel for the installer to configure the Zone Module, and also, for the user to change

More information

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators MAx-305 & MAx-38 Series MAx-405 Through MAx-49 Series Two-Position Actuators General Instructions Application For two-position operation of dampers, valves, and other equipment which require the return

More information

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules Technical Specification Sheet Document No. 149-855 November 04, 2015 BACnet Lab and Pressurized Room Controllers with Off-board Air Modules NOTE: The 570-8xxPA BACnet laboratory controllers have new 67xx

More information

MF4E MF4E

MF4E MF4E MF4E-60830-100 TAC DuraDrive Non-Spring Return Floating Actuator General Instructions Application The 35 lb-in. (4 N-m) and MF4E-60830-100 70 lb-in. (8 N-m) non-spring return, direct-coupled actuators

More information

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,

More information

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas Installation Manual IOM-MBC-00 08-30-04 Mixing Box Control Systems Installation,, and Maintenance Manual Contents Page Introduction...1 General...1 Safety...1 Inspection...1 Mixing Box Control Systems...2

More information

Application Guide Paragon TM Control Module (PCM) Slide Valve and Protection Control 10/25/2016 Rev 1. Carlyle Controller Part No.

Application Guide Paragon TM Control Module (PCM) Slide Valve and Protection Control 10/25/2016 Rev 1. Carlyle Controller Part No. Application Guide 575-012 Paragon TM Control Module (PCM) Slide Valve and Protection Control 10/25/2016 Rev 1 Carlyle Controller Part No. 2BSB000928 1 General Description The PCM is part of Paragon Compressor

More information

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS CRECOMZR05B00 CRECOMZR055B00 VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS TABLE OF CONTENTS PACKAGE USAGE...1 SAFETY CONSIDERATIONS...1 PACKAGE CONTENTS...1 GENERAL...2

More information

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators Installation D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators IMPORTANT: The D- Series actuators are intended to control equipment under normal operating conditions. Where failure

More information

TE-6300 Series Temperature Sensors

TE-6300 Series Temperature Sensors TE-6300 Series Temperature Sensors Product Bulletin Code No. LIT-216320 Issued April 7, 2010 Supersedes March 13, 2009 The TE-6300 Temperature Sensor line provides economical solutions for a wide variety

More information

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS

IMC SOLAR EAGLE 2 DIFFERENTIAL TEMPERATURE CONTROLLERS DIFFERENTIAL TEMPERATURE CONTROLLERS MAIN FEATURES - Microprocessor programed specifically for optimal performance of WARM AIR systems - Large easy-to-read 40 character (x0) backlit LCD display showing

More information

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide 32XR 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide RED ALARM LIGHT LEVEL CONTROLLER H-O-A SWITCHES HORN SILENCE INNER DOOR MOTOR STARTERS WITH INTERCHANGEABLE OVERLOAD MODULES

More information

HL (AZH) LIMIT SWITCHES

HL (AZH) LIMIT SWITCHES COMPACT SIZE LIMIT SWITCHES LIMIT SWITCHES U L PRODUCT TYPE 1. Limit Switches Actuator Type Push plunger Roller plunger Cross roller plunger Panel mount push plunger Panel mount roller plunger Panel mount

More information

Silver Series Thermal Dispersion Airflow Measurement Technology

Silver Series Thermal Dispersion Airflow Measurement Technology Thermal Dispersion Airflow Measurement Model STx104-U Unit Ventilator Airflow Measurement System Technical Data Silver Series Thermal Dispersion Airflow Measurement Technology APPLICATIONS Direct outdoor

More information