Parts List. Model RTT80 I/A Series Temperature Transmitter. PL August 2018

Size: px
Start display at page:

Download "Parts List. Model RTT80 I/A Series Temperature Transmitter. PL August 2018"

Transcription

1 Parts List August 08 Model RTT80 I/A Series Temperature Transmitter Give instrument Model Code when ordering. *Parts preceded by an asterisk are recommended spare parts. See Recommended Spare Parts Summary section for quantities. TO ORDER, CALL

2 Page CODE BB BASIC MODULE HOUSING AND SENSOR MOUNTING CODES CODE BB SURFACE MOUNT BASIC MODULE CODE BB DIN RAIL MOUNT SURFACE BUSHING MOUNTING SCREWS PLACES, PROVIDED BY USER. SEE DP FOR HOLE AND COUNTERBORE DIMENSIONS DIN RAIL OPTIONAL MOUNTING CLIP SELF-TAPPING SCREW UNIVERSAL HOUSING CODES SS AND TT FOR SURFACE/PIPE MOUNTING CODES WW AND YY WITH BARE SENSOR CODES LL AND MM WITH SENSOR AND THERMOWELL CODES GG, HH, QQ, RR FOR SURFACE/PIPE MOUNTING DUAL COMPARTMENT HOUSING CODES CC, DD, JJ, KK, WITH BARE SENSOR CODES EE, FF, NN, PP WITH SENSOR AND THERMOWELL

3 MODEL CODE Page 3 Description MODEL CODE I/A Series Temperature Transmitter Communications to 0 ma with HART digital communications FOUNDATION fieldbus H digital communications Input/Output Configuration Configured for Single Sensor Input Configured for Dual Sensor Input PV is Sensor (a) Configured for Dual Sensor Input PV is average of Sensor and Sensor (a) Configured for Dual Sensor Input PV is difference between Sensor and Sensor (a) Configured for Dual Sensor Input Sensor is a backup for Sensor (a) Configured for Dual Sensor Input PV is average with sensor backup (a) Housing and Sensor Mounting Basic Module for DIN Rail or Surface Mounting or Replacement Dual compartment aluminum housing, / NPT conduit with sensor (b) Dual compartment ss housing, / NPT conduit with sensor (b) Dual compartment aluminum housing, / NPT conduit with sensor and thermowell mounting (b) Dual compartment ss housing, / NPT conduit with sensor and thermowell mounting (b) Dual compartment aluminum housing, / NPT conduit for use with remote sensor (c) Dual compartment ss housing, / NPT conduit for use with remote sensor (c) Dual compartment aluminum housing, M0 conduit with sensor (b) Dual compartment ss housing, M0 conduit with sensor (b) Dual compartment aluminum housing, M0 conduit with sensor and thermowell mounting (b) Dual compartment ss housing, M0 conduit with sensor and thermowell mounting (b) Dual compartment aluminum housing, M0 conduit for use with remote sensor (c) Dual compartment ss housing, M0 conduit for use with remote sensor (c) Universal aluminum housing for use with remote sensor (c) Universal ss housing for use with remote sensor (c) Universal aluminum housing with bare sensor (b) Universal ss housing with bare sensor (b) Universal aluminum housing with sensor and thermowell mounting (b) Universal ss housing with sensor and thermowell mounting (b) Input Measurement Type (d) Thermocouple, Type B (e) Thermocouple, Type C (e) Thermocouple, Type D (e) Thermocouple, Type E Thermocouple, Type J Thermocouple, Type K Thermocouple, Type L (e) Thermocouple, Type N Thermocouple, Type R (e) Thermocouple, Type S (e) Thermocouple, Type T Thermocouple, Type U (e) -wire RTD, 00 ohm platinum IEC 75 (ASTM-B Standard Accuracy) (e) 3-wire RTD, 00 ohm platinum IEC 75 (ASTM-B Standard Accuracy) -wire RTD, 00 ohm platinum IEC 75 (ASTM-B Standard Accuracy) (f) 3-wire RTD, 00 ohm platinum IEC 75 (ASTM-A High Accuracy) -wire RTD, 00 ohm platinum IEC 75 (ASTM-A High Accuracy) (f) 3-wire RTD, 00 ohm nickel DIN 3760 (e) Ohms input Millivolt input 3-wire RTD Platinum (Callendar-van Dusen) Other (factory configuration for an Input Measurement Type not listed above) (g) Thermowell Assembled to Housing No Thermowell or Thermowell is supplied separately (h) Thermowell Series T- assembled to housing; specify child thermowell (i) Thermowell Series W- assembled to housing; specify W- model code (j) Model RTT80 -T -F BB JJ KK NN PP QQ RR CC DD EE FF GG HH SS TT WW YY LL MM B C D E J K L N R S T U Q A 6 F P M W Z NA TK TX

4 Page MODEL CODE Description MODEL CODE (Continued) Hazardous Area Certifications (k) Non-hazardous area CSA IS, I/+/ABCD CSA NI, //ABCD CSA Explosionproof, Class I, Division, BCD; Dust-ignitionproof, Class II, Division, EFG, Class III, Division. Also zone certified, CL I, Zone, EX d IIC (l) ATEX II G Ex ia IIC T/T5/T6 ATEX II G Ex d T6 Gb (l) IECEx Ex ia IIC T/T5/T6 (l) IECEx Ex d T6 Gb (l) FM IS, I/+/ABCD FM NI, I//ABCD FM Explosionproof, Class I, Division, Groups B, C, and D; Dust-ignitionproof, Class II, Division, Groups E, F, and G, Class III Division (l) EAC Flameproof Ex d IIC T6 Gb; (l) EAC Intrinsic Safe 0Ex ia IIC T6 Ga; T/T5/T6 (l) INMETRO Flameproof Ex d IIC T6 Gb; Ex tb IIIC; IP66/67 (l) Optional Selections Housing Features Custody Transfer Lock and Seal (l) Metric M0 Conduit Adapter (/ NPT by M0x.5) (m) Housing Connection to Thermowell Stainless Steel Union and Fittings (n) -S3 Mounting Sets Mounting Set for Universal Housing Painted Steel (m) Mounting Set for Universal Housing Stainless Steel (m) Mounting Set for Dual Compartment Housing Painted Steel (o) Mounting Set for Dual Compartment Housing Stainless Steel (o) Mounting Set for Dual Compartment Housing Rugged Painted Steel (p) Mounting Set for Dual Compartment Housing Rugged Stainless Steel (p) Clip for DIN rail mounting of the basic module Other Optional Features SIL Certification (q) Custom Database Configuration Omit FoxDoc CD-ROM With Local Indicator Cleaned and Prepared for Oxygen Service (l) Wake Frequency Calculations (r) NACE Compliant Thermowell (r) (s) Model a. Input measurement must be the same for both sensors. Dual -wire RTD is not permitted. Only Input can be configured for - wire RTD. b. This option initiates the PRMTA configurable sensor model code. If you are ordering a PRMTA configurable sensor, be sure that the RTT80 Input Measurement Type ordered matches the PRMTA Configurable Sensor Input Measurement Type. c. Sensor ordered separately. d. Transmitter is factory configured for the measurement type specified whether the sensor is included or not. You can change the configuration to a different type using appropriate configuration software for the selected protocol, or specify -C Option for custom factory configuration. On dual sensor input (Sensor Input = ), both inputs are configured the same, unless specified via the -C configuration form. e. Only available with the basic module or a module for use with a remote sensor (Housing and Sensor Mounting Codes BB, QQ, RR, GG, HH, SS, TT). f. Only available with single sensor input (Input/Output Configuration Code ). g. This option requires selection of the Custom Database Configuration (Model Code Option -C) under Other Optional Features. h. This option is required for all housing options that are not configured for thermowells (Housing and Sensor Mounting Codes BB, JJ, KK, QQ, RR, CC, DD, GG, HH, SS, TT, WW, and YY). i. This option allows you to select a PRMTA configurable sensor with TT, TF, TS, or TW thermowell codes. j. Refer to PSS 3-3C A for available W Series thermowells. k. Transmitter has been designed to meet the Electrical Safety descriptions listed in this table. Contact Global Customer Support for information and status of testing laboratory approvals or certifications l. Not available with the basic module (Housing and Sensor Mounting Code BB). m. Only available with universal housings (Housing and Sensor Mounting Codes SS, TT, WW, YY, LL, MM). ZZ CA CN CD AA AD EA ED FA FN FD RD RA BD -A -A3 -M -M -M3 -M -M5 -M6 -D -S -C -K -L -C5 -WF -N

5 Page 5 n. Optionally available with aluminum housings configured for sensor and thermowell mounting (Housing and Sensor Mounting Codes NN, EE, and LL). Standard on ss housings configured for sensor and thermowell mounting (Housing and Sensor Mounting Codes PP, FF, and MM). o. Only available with aluminum dual compartment housings (Housing and Sensor Mounting Codes CC, EE, GG, JJ, NN, QQ). p. Required for SS dual compartment housings (Housing and Sensor Mounting Codes KK, PP, RR, and DD) if a mounting set is desired. Also available with aluminum dual compartment housings (Housing and Sensor Mounting Codes JJ, NN, QQ, and CC) if a mounting set is desired. q. SIL available only with HART Communications option (-T). r. Requires universal or dual compartment housings with sensor and thermowell mounting options (Housing and Sensor Mounting Codes NN, PP, EE, FF, LL, or MM). s. Only available with Thermowell Option Code TK ( T- thermowell assembled to housing). Figure. Basic Transmitter Module Housing Code BB Table. Parts List for Figure : Basic Transmitter Module Housing Code BB * Below D097UA D07HD D07HE D097UC a. Availability limited; check with Global Customer Support. Module, Basic Transmitter with HART 6 Protocol (a) with HART 7 Protocol and SIL Option with HART 7 Protocol and without SIL Option with FOUNDATION Fieldbus Protocol

6 Page 6 Figure. Universal Housing and Transmitter with Sensors and Thermowells Housing Codes SS and TT 8 COVER FOR USE WITHOUT LCD INDICATOR COVER FOR USE WITH OPTIONAL LCD INDICATOR 3 MODULE LABEL (REFERENCE) AGENCY AND DATA PLATES (REFERENCE) 0 0 THERMOWELL 9 UNION 7 BARE ELEMENT MOUNT 8 THERMOWELL MOUNT (SPRING LOADED)

7 Page 7 Table. Parts List for Figure : Universal Housing and Transmitter with Sensors and Thermowells Housing Codes SS and TT Below D058KN B0300CD D097UE D097UQ * Below D097UA D097UC Cover Aluminum Cover, Solid, Housing Code SS Stainless Steel Cover, Solid, Housing Code TT Aluminum Cover, with Window, Housing Code SS Stainless Steel Cover, with Window, Housing Code TT Module, Basic Transmitter with HART Protocol with FOUNDATION Fieldbus Protocol 3 X07FM Screw, Module Mounting, x * D097UD Optional LCD Display 5 X07FL Standoff 6 X07FJ Washer *7 X0MZ O-Ring, Cover 8 Below X0AT X0AA 9 Below B0300BJ B0300BU B0300CB A/R Lubricant (for aluminum) Lubricant (for stainless steel) Housing, Universal Aluminum; Housing Code SS; not with ATEX Flameproof Aluminum; Housing Code SS; use with ATEX Flameproof Stainless Steel; Housing Code TT 0 B76ZU Screw, self-tapping; ss; x 0.87 X07FW Screw, Earth (Ground); x 0.3 X073YA Washer, flat A/R Lubricant N0305RN Clamp, Earth (Ground), stainless steel 5 Below B0300BW B0300AU B0300CU 6 Below N600XX X033YD Cover Lock Epoxy coated aluminum; with Housing Code SS ss LL piece, with Housing Code TT (a) ss UU piece, with Housing Code TT (a) Screw, Lock; x with Housing Code SS with Housing Code TT 7 See PL Bare Element Mount Assembly; refer to PL See PL Spring-loaded Thermowell Mount Assembly; refer to PL See PL Union - used with spring loaded sensor and thermowell; / NPT internal thread;.3 inches long; refer to PL See PL Thermowells, Plain or Lagging; refer to PL a. The LL and UU pieces are mating parts and comprise Item 5 for the stainless steel Housing Code TT.

8 Page 8 Figure 3. Universal Housing and Transmitter with Sensors and Thermowells Housing Codes LL, MM, WW, and YY 8 COVER FOR USE WITHOUT LCD INDICATOR COVER FOR USE WITH OPTIONAL LCD INDICATOR 3 MODULE LABEL (REFERENCE) AGENCY AND DATA PLATES (REFERENCE) 0 THERMOWELL 9 UNION 7 BARE ELEMENT MOUNT 8 THERMOWELL MOUNT (SPRING LOADED)

9 Page 9 Table 3. Parts List for Figure 3: Universal Housing and Transmitter with Sensors and Thermowells Housing Codes LL, MM, WW, and YY Below D058KN B0300CD D097UE D097UQ * Below D097UA D097UC Cover, Housing Codes LL, MM, WW, and YY Aluminum; Housing Codes LL and WW Stainless Steel; Housing Codes MM and YY Aluminum Cover, with Window, Housing Codes LL and WW Stainless Steel Cover, with Window, Housing Codes MM and YY Module, Basic Transmitter, with HART Protocol; also see Figures and with FOUNDATION Fieldbus Protocol; also see Figures and 3 X07FM Screw, Module Mounting, x D097UD Optional LCD Display 5 X07FL Standoff 6 X07FJ Washer *7 X0MZ O-Ring, Cover, with Universal Housing, Housing Codes LL, MM, WW, and YY 8 Below X0AT X0AA 9 Below B0300BJ B0300BU B0300CB A/R Lubricant (for aluminum) Lubricant (for stainless steel) Housing, Universal, Housing Codes LL, MM, WW, and YY Aluminum; Housing Codes LL and WW, not with ATEX Flameproof Aluminum; Housing Codes LL and WW, use with ATEX Flameproof Stainless Steel; Housing Codes MM and YY 0 B76ZU Screw, self-tapping; ss; x 0.87 X07FW Screw, Earth (Ground); x 0.3 X073YA Washer, flat A/R Lubricant N0305RN Clamp, Earth (Ground), stainless steel 5 Below B0300BW B0300AU B0300CU 6 Below N600XX X033YD Cover Lock; with Housing Codes LL, MM, WW, and YY Epoxy coated aluminum; with Housing Codes LL and WW ss "LL" piece, with Housing Codes MM and YY ss "UU" piece, with Housing Codes MM and YY Screw, Lock; x 0.375; with Housing Codes LL, MM, WW, and YY Plated cs, hex socket hd; with Housing Codes LL and WW ss, hex socket hd; with Housing Codes MM and YY 7 See PL Bare Element Mount Assembly; refer to PL See PL Spring-loaded Thermowell Mount Assembly; refer to PL See PL Union - used with spring loaded sensor and thermowell; / NPT internal thread;.3 inches long; refer to PL See PL Thermowells, Plain or Lagging; refer to PL

10 Page 0 Figure. Dual Compartment Housing and Transmitter Housing Codes CC, DD, EE, FF, GG, HH, JJ, KK, NN, PP, QQ and RR COVER FOR USE WITH OPTIONAL LCD INDICATOR COVER FOR USE WITHOUT LCD INDICATOR THERMOWELL MOUNT (SPRING LOADED) 7 9 THERMOWELL 8 UNION 6 BARE ELEMENT MOUNT Table. Parts List for Figure : Dual Compartment Housing and Transmitter Housing Codes CC, DD, EE, FF, GG, HH, JJ, KK, NN, PP, QQ and RR * Below D097UA D097UC X07FM Screw, Captive * D097UD Optional LCD Display Module, Basic Transmitter with HART Protocol with FOUNDATION fieldbus Protocol; also see Figures and

11 Page 5 Below D097VA D097VK D097VR D097VT D097VB D097VL D097VS D097VU 6 Below X0AT X0AA A/R 8 D06AJ Data Plate Blank, Dual 9 B0300FT Data Label Below D066AD D066AL Dual compartment housing, Aluminum, / NPT; for use with Electrical Certification Safety Codes CN, CA, AN, AA, FN, EA, EN and Housing Code JJ, NN, QQ Dual compartment housing, Aluminum, / NPT; for use with Electrical Certification Safety Codes CD, AD, and FD, ND, ED and Housing Code JJ, NN, QQ Dual compartment housing, ss, / NPT; for use with Electrical Certification Safety Codes CN, CA, AN, AA, FA, FN, EA, EN and Housing Code KK, PP, RR Dual compartment housing, ss, / NPT; for use with Electrical Certification Safety Codes CD, AD, FD, ND, ED and Housing Code KK, PP, RR Dual compartment housing, Aluminum, M0; for use with Electrical Certification Safety Codes CN, CA, AN, AA, FN, EA, EN and Housing Codes CC, DD, EE, FF, GG, or HH Dual compartment housing, Aluminum, M0; for use with Electrical Certification Safety Codes CD, AD, FD, ND, or ED and Housing Codes CC, DD, EE, FF, GG, or HH Dual compartment housing, ss, M0; for use with Electrical Certification Safety Codes CN, CA, AN, AA, FN, EA, or EN and Housing Codes CC, DD, EE, FF, GG, or HH Dual compartment housing, ss, M0; for use with Electrical Certification Safety Codes CD, AD, FD, ND, or ED and Housing Codes CC, DD, EE, FF, GG, or HH Lubricant Cover, Machined Cover, Machined, SS *3 X0MZ O-ring, cover X07FW Screw, Internal Sems 5 X00LY O-ring, neck D06WM Cover Lock, Screw X073YA Washer, Flat 6 N0305RN Clamp, Ground 7 B0300AU Cover Lock, U SST 30 D09ZA Terminal Block Assembly 3 D097PS Anti Rotation Clip 3 X07EK Button Head Screw 3 X0KR O-ring, Terminal Block 35 B039CA Pipe Plug 36 D097VF Mounting Bracket Assembly 37 Below K08TX D097VQ Table. Parts List for Figure : Dual Compartment Housing and Transmitter Housing Codes CC, DD, EE, FF, GG, HH, JJ, KK, NN, PP, QQ and RR (Continued) Neck Neck, Machined Neck, Machined, Remote Mounting 38 N039FR Tie, Wrap 39 X07FV Screw, Captive Panel 0 D06VJ Screw Assembly Below Screw, Hex Socket Head X033UW X033VP X073TV Washer, Plain 3 S006ML A/R Loctite A/R Lubricant 5 X03RK Washer, Lock

12 Page Table. Parts List for Figure : Dual Compartment Housing and Transmitter Housing Codes CC, DD, EE, FF, GG, HH, JJ, KK, NN, PP, QQ and RR (Continued) 6 See PL Bare Element Mount Assembly; refer to PL See PL Spring-loaded Thermowell Mount Assembly; refer to PL See PL Union - used with spring loaded sensor and thermowell; / NPT internal thread;.3 inches long; refer to PL See PL Thermowells, Plain or Lagging; refer to PL Figure 5. Optional Custody Transfer Lock and Seal (Option -A) with Housing Codes LL, SS, and WW (Aluminum Housings) and Housing Codes MM, TT, and YY (ss Housings) B0300BW SHOWN HOUSING (REFERENCE) 3 3 Table 5. Parts List for Figure 5: Optional Custody Transfer Lock and Seal (Option -A) with Housing Codes LL, SS, and WW (Aluminum Housings) and Housing Codes MM, TT, and YY (ss Housings) Below B0300BW B0300AU B0300CU Below N600XX X033YD 3 S00806 Lead Seal S00807 A/R Sealing Wire Cover Lock; with Housing Codes LL, MM, SS, TT, WW, and YY Epoxy coated aluminum; with Housing Codes LL, SS, and WW ss LL piece, with Housing Codes MM, TT, and YY (a) ss UU piece, with Housing Codes MM, TT, and YY (a) Screw, Lock; x 0.375; with Housing Codes LL, MM, SS, TT, WW, and YY Plated cs, hex socket head; with Housing Codes LL, SS, and WW ss, hex socket hd; with Housing Codes MM, TT, and YY a. The LL and UU pieces are mating parts and comprise Item for the MM, TT, and YY stainless steel housings. Items and are standard construction with Electrical Safety Code AD, ATEX flameproof. If, however, Items 3 and (seal and wire) are also required with ATEX flameproof construction, then specify Option -A to also receive the seal and wire.

13 Page 3 Figure 6. Optional Custody Transfer Lock and Seal (Option -A) with Housing Codes CC, DD, EE, FF, GG, HH, JJ, KK, NN, PP, QQ, and RR 3 3 Table 6. Parts List for Figure 6: Optional Custody Transfer Lock and Seal (Option -A) with Housing Codes CC, DD, EE, FF, GG, HH, JJ, KK, NN, PP, QQ, and RR D06WM Locking Screw, S00806 Lead Seal 3 S00807 A/R Sealing Wire Below X0AJ X080JB A/R Grease, Lubriplate (-3/ ounce tube) for Aluminum for Stainless Steel NOTE Item is standard construction with all dual compartment housing options. If, however, Items 3 and (seal and wire) are also required, then specify Option -A to also receive the seal and wire.

14 Page Figure 7. Optional Metric Conduit Thread Adapter (Option -A3) with Housing Codes LL, MM, SS, TT, WW, and YY Housing Codes SS and TT are shown. Table 7. Parts List for Figure 7: Optional Metric Conduit Thread Adapter (Option -A3) with Housing Codes LL, MM, SS, TT, WW, and YY N7DX Metric Conduit Thread Adapter; ss, / NPT to M0 x.5-6h Figure 8. Optional DIN Rail Mounting (Option -D) withhousingcodebb(basicmodule) 3 DIN RAIL Table 8. Parts List for Figure 8: Optional DIN Rail Mounting (Option -D) with Housing Code BB (Basic Module) X075MJ Mounting Clip, DIN Rail; gray plastic X07FK Screw, self-tapping; plated steel, x X00PX Bushing, Shoulder

15 Page 5 PIPE MOUNTING Figure 9. Optional Mounting Sets (Options -M and -M) with Housing Codes SS, TT, WW, YY, LL, and MM VERTICAL PIPE SHOWN SURFACE MOUNTING Table 9. Parts List for Figure 9: Optional Selection -M: Carbon Steel (Finished) B0300DR Mounting Kit, carbon steel B0300DQ Bracket, Mounting; painted steel D0SM U-Bolt; plated steel, 0.3-8,.75 x A05AB Washer, lock; ss, 0.3 X0BV Nut, hex head, plated steel; X066YE Screw, pnhd, cross-recessed; plated steel, x Washer, lock; ss, Washer, plain; plated steel, 0.50 (wide) Table 0. Parts List for Figure 9: Optional Selection -M: Stainless Steel B060AB Mounting Kit, stainless steel B060AA Bracket, Mounting; ss N05MX U-Bolt; ss, 0.3-8,.75 x A05AB Washer, lock; ss, 0.3 X0BW Nut, hex head, ss; X08KT Screw, pnhd, cross-recessed; ss, x Washer, lock; ss, X09DY Washer, plain; ss, 0.50 (wide)

16 Page 6 Figure 0. Optional Mounting Sets (Options -M3, -M, -M5, -M6) with Housing Codes CC, DD, EE, FF, GG, HH, JJ, KK, NN, PP, QQ, RR 5 3 Table. Parts List for Figure 0: Optional Selection -M3: Standard Carbon Steel Bracket Mounting Kit D097VC Mounting Kit, carbon steel D097WE Standard Mounting Bracket; painted steel M09AN U-Bolt; plated steel, 0.3-8,.75 x Nut, hex head, plated steel; X038DX Bolt, hex head, ss 5 X07FU Washer, type B flat, #3/8 Table. Parts List for Figure 0: Optional Selection -M: Standard Stainless Steel Bracket Mounting Kit D097VD Mounting Kit, stainless steel D097VJ Standard Mounting Bracket; ss X07EU U-Bolt; ss, 0.3-8,.75 x Z7HV Nut, hex head, ss; X038DX Bolt, hex head, ss 5 X07FU Washer, type B flat, #3/8 Table 3. Parts List for Figure 0: Optional Selection -M5: Rugged Carbon Steel Bracket Mounting Kit D097WC Mounting Kit, rugged carbon steel bracket K05RP Rugged Mounting Bracket; painted steel M09AN U-Bolt; plated steel, 0.3-8,.75 x Nut, hex head, plated steel; X038DX Bolt, hex head, ss 5 X07FU Washer, type B flat, #3/8 Table. Parts List for Figure 0: Optional Selection -M6: Rugged Stainless Steel Bracket Mounting Kit D097WD Mounting Kit, rugged stainless steel bracket K053VU Rugged Mounting Bracket; ss

17 RECOMMENDED SPARE LIST Page 7 Table. Parts List for Figure 0: Optional Selection -M6: Rugged Stainless Steel Bracket Mounting Kit X07EU U-Bolt; ss, 0.3-8,.75 x Z7HV Nut, hex head, ss; X038DX Bolt, hex head, ss 5 X07FU Washer, type B flat, #3/8 NOTE For a complete listing of thermowells, refer to PSS 3-3C A for W-Series thermowells and PSS 3-3D A for T-Series wells. Figure Number Figure Figure 3 Item Number Part Number RECOMMENDED SPARE LIST Part Name Number of Parts Recommended for Inst. 5 Inst. 0 Inst. 7 7 X0MZ O-Ring, Cover (universal housing) Figure 3 O-Ring, Cover (dual compartment housing) 8 Figure Figure 3 Figure D097UD Optional LCD Display

18 Page 8 Schneider Electric Systems USA, Inc. 38 Neponset Avenue Foxboro, MA 0035 United States of America Global Customer Support Inside U.S.: Outside U.S.: Copyright 0-08 Schneider Electric Systems USA, Inc. All rights reserved. Schneider Electric and I/A Series are trademarks of Schneider Electric Systems USA, Inc., its subsidiaries, and affiliates. All other trademarks are the property of their respective owners. 088

Foxboro Model 84C Vortex Flowmeters Flanged Body Flowmeters

Foxboro Model 84C Vortex Flowmeters Flanged Body Flowmeters Parts List PL 008-754 June 2015 Foxboro Model 84C Vortex Flowmeters Flanged Body Flowmeters Give instrument Model Code when ordering. *Parts preceded by an asterisk are recommended spare parts. See Recommended

More information

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L Temperature Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L WIKA data sheet TE 65.12 for further approvals see page 2 Applications Chemical industry Petrochemical industry

More information

Flanged Body. Style A

Flanged Body. Style A Parts List PL 008-708 June 2008 I/A Series Vortex Flowmeters Model 83F-D with FoxCom Communication Protocol Model 83F-T with HART Communication Protocol Model 83F-F with FOUNDATION Fieldbus Communication

More information

Rosemount 3051CFA Annubar Flowmeter

Rosemount 3051CFA Annubar Flowmeter December 2013 Rosemount 3051 Rosemount 3051CFA Annubar Flowmeter The Rosemount 3051CFA Annubar Flowmeter utilizes the patented T-shaped sensor design that delivers best in class accuracy and performance.

More information

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L Temperature Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L WIKA data sheet TE 60.12 for further approvals see page 2 Applications Chemical industry Petrochemical

More information

BETA SWITCHES FOR HAZARDOUS AREA

BETA SWITCHES FOR HAZARDOUS AREA BETA offers complete line of switches for (classified) hazardous locations! The BETA Switch, well known as a safety instrument, adds an extra dimension to industrial safety by having area approval up to

More information

Rosemount 68 Sensor and Thermowell

Rosemount 68 Sensor and Thermowell Rosemount 68 Sensor and Thermowell The Rosemount 78 Sensor and Thermowell have designs that provide flexible and reliable temperature measurements in process environments. Features include: Industry-standard

More information

Measuring insert for resistance thermometer Model TR10-A

Measuring insert for resistance thermometer Model TR10-A Electrical temperature measurement Measuring insert for resistance thermometer Model TR1-A WIKA data sheet TE 6.1 for further approvals see page 6 Applications Replacement measuring insert for servicing

More information

Thermocouple For additional thermowell Model TC10-B

Thermocouple For additional thermowell Model TC10-B Temperature Thermocouple For additional thermowell Model TC10-B WIKA data sheet TE 65.02 for further approvals see page 2 Applications Machine building, plant and vessel construction Energy and power plant

More information

Rosemount 3051T In-Line Pressure Transmitter

Rosemount 3051T In-Line Pressure Transmitter Rosemount 3051T In-Line Pressure Transmitter Rosemount 3051T In-line Pressure Transmitters are the industry standard for Gage, and Absolute pressure measurement. The in-line, compact design allows the

More information

IGP10, IGP20 Intelligent Gauge Pressure Transmitters IAP10 Intelligent Absolute Pressure Transmitter

IGP10, IGP20 Intelligent Gauge Pressure Transmitters IAP10 Intelligent Absolute Pressure Transmitter , Intelligent Gauge Pressure Transmitters Intelligent Absolute Pressure Transmitter 1 for compact light weight and direct-to-process mounting (bracket optionally available), bracket mounted, for lower

More information

Rosemount Pipe Clamp RTD Sensor

Rosemount Pipe Clamp RTD Sensor Product Data Sheet Platinum RTD Temperature Sensors with silver or nickel tip Non intrusive design for measurement on pipe applications Temperature-sensor matching provides increased measurement accuracy

More information

APPLICATION MANUAL. Universal Explosionproof Two-Compartments Instrument Housing Type: XD-ID100, XD-ID100win, XD-ID100H, XD-ID100Hwin

APPLICATION MANUAL. Universal Explosionproof Two-Compartments Instrument Housing Type: XD-ID100, XD-ID100win, XD-ID100H, XD-ID100Hwin Updated 09.11.16 APPLICATION MANUAL Universal Explosionproof Two-Compartments Instrument Housing Type: XD-ID100, XD-ID100win, XD-ID100H, XD-ID100Hwin Contents: 1. Destination. 2. Flameproof joints, process

More information

INTERNATIONAL METAL ENGINEERING

INTERNATIONAL METAL ENGINEERING INDICATING TEMPERATURE TRANSMITTER WITH HART 8080HT UNIVERSAL SETTINGS WITH HART PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE TECHNOLOGY, 4 TO 20mA ANALOG OUTPUT HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL

More information

User s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition

User s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition User s Manual Model MLD Loop Powered Process Indicator 4th Edition 1. PREFACE The Model MLD field mounted indicator receives a DC current signal from electronic transmitters and indicates process measurement

More information

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications Product Data Sheet Rosemount 3051 FIELDBUS PROTOCOL Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof

More information

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module Electrical temperature measurement Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module WIKA data sheet TE 60.17 for further approvals see page 6 Applications

More information

Resistance thermometer Model TR10-E, for additional thermowell

Resistance thermometer Model TR10-E, for additional thermowell Electrical temperature measurement Resistance thermometer Model TR10-E, for additional thermowell WIKA data sheet TE 60.05 further approvals see page 6 Applications Chemical industry Petrochemical industry

More information

Rosemount 4088 MultiVariable Transmitter

Rosemount 4088 MultiVariable Transmitter Product Data Sheet May 2015 00813-0100-4088, Rev AC Rosemount 4088 MultiVariable Transmitter With the innovative Rosemount 4088 MultiVariable Transmitter, you can maximize your measurement accuracy and

More information

Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation Product Data Sheet January 2013 00813-0100-4801, Rev RA Rosemount 3051S Series of Instrumentation Scalable Pressure, Flow, and Level Solutions Innovation Reaching Across Your Operation With the Rosemount

More information

Spring loaded resistance thermometer

Spring loaded resistance thermometer Spring loaded resistance thermometer THERMOWELL & REPLACEABLE INSERT C200-201-204-205-260-262 CONFIGURATIONS Ex ia RTD Product series PT100RI/WI C200 C201 C204 C205 C260 C262 2 Features assembly The industrial

More information

Rosemount 214C Temperature Sensors

Rosemount 214C Temperature Sensors Product Data Sheet March 2018 00813-0500-2654, Rev DB Rosemount 214C Temperature Sensors Primary product benefits High accuracy resistance temperature detectors (RTD) and various thermocouple types offered

More information

Parts List. TCE_8501_Parts_M_EN_170308_E001 TRICOR TCE 8501

Parts List. TCE_8501_Parts_M_EN_170308_E001 TRICOR TCE 8501 Parts List TCE_8501_Parts_M_EN_170308_E001 TRICOR TCE 8501 Version Manual-Version TCE_8501_Parts_M_EN_170308_E001 SW-Version This manual is valid for Main SW: Mv3.40 and higher Display SW: Dv3.40 and higher

More information

Bimba Extruded Linear Thrusters 2X FF X EE DP 2X DD 2X Ø DD X EE DP U V W X Y Z R S Dimensions - ET T B 4X TAP AA THRU Ø BB C BORE X CC DP (OPP.SIDE)

Bimba Extruded Linear Thrusters 2X FF X EE DP 2X DD 2X Ø DD X EE DP U V W X Y Z R S Dimensions - ET T B 4X TAP AA THRU Ø BB C BORE X CC DP (OPP.SIDE) Bimba Extruded Linear Thrusters Engineering Specifications Maximum Operating Pressure 140 psi (10 bar) Temperature Range 15 to 160 degrees F (-10 to 70 degrees C) Expected Service Life 1,500 miles (with

More information

Assembly. Trunk IN + - S U, I U, I. Spur 1

Assembly. Trunk IN + - S U, I U, I. Spur 1 FieldBarrier FD0-FB-Ex.* Features Assembly outputs Ex ia IIC FieldBarrier in Zone /Div. Instruments in Zone 0.../Div. Short circuit current limitation per output For FOUNDATION Fieldbus H and PROFIBUS

More information

Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation Product Data Sheet 3051S Series delivers highest field performance and reliability SuperModule Platform provides a foundation for integrated pressure, flow, and level solutions IEC 62591 (WirelessHART

More information

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D EJB Junction Boxes Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4X*,, Ex d IIB + H2 T6, IP66 Explosionproof Dust-Ignitionproof Raintight

More information

Features. Suitable for use in SIL 2 applications. Available in LP low power version with less than 1.65 A current consumption. General application

Features. Suitable for use in SIL 2 applications. Available in LP low power version with less than 1.65 A current consumption. General application The ICON 2000 v4 series are electronically-configurable quarter and multi-turn actuators with advanced operation, control, setting and maintenance characteristics Features General application The ICON

More information

Field Installation of the Joystick Conversion Kit (DUAL CONTROL){1408, 5057, 5059, 5264, 5705}

Field Installation of the Joystick Conversion Kit (DUAL CONTROL){1408, 5057, 5059, 5264, 5705} Media Search - REHS1805 - Field Installation of the 233-5720 Joystick Conversion K Page 1 of 54 Special Instruction Field Installation of the 233-5720 Joystick Conversion Kit (DUAL CONTROL){1408, 5057,

More information

Rosemount 3051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter Product Data Sheet Rosemount 3051 Rosemount 3051 Pressure Transmitter THE PROVEN INDUSTRY LEADER IN PRESSURE MEASUREMENT Best-in-Class performance with up to 0.04% reference accuracy Industry first installed

More information

Linear Thrusters/PneuMoment

Linear Thrusters/PneuMoment /PneuMoment Extruded TE Series 3.3-3.10 3.11-3.16 T Series Multiple Position T4 Series Movable Housing 3.17-3.22 3.23-3.24 3.25-3.28 3.29-3.32 Pneu-Moment Checklist PneuMoment Pneumatic Actuators PneuMoment

More information

Position Switches Series 8070/2

Position Switches Series 8070/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50041 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

Tubeskin thermocouple assembly Model TC59-V

Tubeskin thermocouple assembly Model TC59-V Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-V WIKA data sheet TE 65.59 further approvals see page 7 V-PAD Applications Chemical industry Superheated steam applications

More information

Rosemount 3051S Electronic Remote Sensor (ERS) System

Rosemount 3051S Electronic Remote Sensor (ERS) System Rosemount 3051S Electronic Remote Sensor (ERS) System The Rosemount 3051S ERS System is a flexible, 2-wire 4-20 ma ART architecture that calculates differential pressure (DP) electronically using two pressure

More information

Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation Product Data Sheet 00813-0100-4801, Rev UK December 2018 Rosemount 3051S Series of Instrumentation Innovation reaching across your operation With the Rosemount 3051S Series of Instrumentation, operations

More information

ATEX/IECEx RTD temperature probe

ATEX/IECEx RTD temperature probe Page 1/8 ATEX/IECEx RTD temperature probe with connecting cable acc. to DIN EN 60751 For temperatures from -100 to +600 C As single, double, or triple RTD temperature probe In two-wire, three-wire, or

More information

Rosemount 3051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter Rosemount 3051 Pressure Transmitter Product Data Sheet April 2014 00813-0100-4001, Rev RC With the Rosemount 3051 Pressure Transmitter, you ll gain more control over your plant. You ll be able to reduce

More information

Terminal Boxes Series 8252/1

Terminal Boxes Series 8252/1 www.stahl.de > Ex d enclosure made of saltwater-resistant, copper-free aluminium cast alloy > Powder coated to RAL 7032 > Available in 3 different sizes > With DIN rail for standard terminals > Enclosure

More information

INTERNATIONAL METAL ENGINEERING

INTERNATIONAL METAL ENGINEERING INSTRUMENT ENCLOSURES, JUNCTION BOXES, STOPPING PLUGS, TEMPERATURE ASSEMBLIES AND A WIDE RANGE OF INDICATORS, TRANSMITTERS AND BATCH CONTROLLERS FM, CSA, ATEX, IECEx CERTIFIED OCTOBER 2015 INTERNATIONAL

More information

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K Temperature Measuring insert For thermocouple with flameproof enclosure (TC1-L) Model TC1-K WIKA data sheet TE 65.11 for further approvals see page 2 Applications Replacement measuring insert for servicing

More information

FIELD DEVICES - PRESSURE

FIELD DEVICES - PRESSURE FIELD DEVICES - PRESSURE Product Specifications Logo Models IAP10, IGP10, IAP20, and IGP20 I/A Series Electronic Absolute and Gauge Pressure Transmitters with 4 to 20 ma Analog Output PSS 2A-1C13 C IAP20/IGP20

More information

Rosemount 4088 MultiVariable Transmitter

Rosemount 4088 MultiVariable Transmitter Product Data Sheet January 2018 00813-0100-4088, Rev BA Rosemount 4088 MultiVariable Transmitter With the innovative Rosemount 4088 MultiVariable Transmitter, you can maximize your measurement accuracy

More information

Tubeskin thermocouple assembly Model TC59-W

Tubeskin thermocouple assembly Model TC59-W Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-W WIKA data sheet TE 65.58 further approvals see page 7 WELD-PAD Applications Chemical industry Power generation Refineries

More information

User s Manual. Model MLA & MLD Loop Powered Process Indicators. Model MLD (Digital) Model MLA (Analog)

User s Manual. Model MLA & MLD Loop Powered Process Indicators. Model MLD (Digital) Model MLA (Analog) User s Manual Model MLA & MLD Loop Powered Process Indicators Model MLD (Digital) Model MLA (Analog) 1. PREFACE The Model MLA and MLD field mounted indicators receive DC voltage or current signals by electronic

More information

Temperature Measurement Resistance thermometers

Temperature Measurement Resistance thermometers Temperature transmitters for mounting in the connection head The following temperature transmitters are available for mounting in the connection head: SITRANS TH100 Programmable two-wire temperature transmitter

More information

Rosemount 183 Sensor and Thermowell

Rosemount 183 Sensor and Thermowell Rosemount 183 Sensor and Thermowell The Rosemount 183 Sensor and Thermowell have designs that provide flexible and reliable temperature measurements in process environments. Features include: Industry-standard

More information

FM, CSA, ATEX, IECEx CERTIFIED

FM, CSA, ATEX, IECEx CERTIFIED NOV 2014 FM, CSA, ATEX, IECEx CERTIFIED COMPANY PROFILE E stablished in 1991 by a group of engineers with a wealth of experience in instrument and process control, IME has developed a complete line of

More information

Model 5-025, 5-050, &

Model 5-025, 5-050, & Model 5-025, 5-050, 5-075 & 5-150 7 Model 5-025, 5-050, 5-075 & 5-150 8 Eductor Block Exploded View Model 5-025, 5-050, 5-075 & 5-150 9 Figure 1 Item Part Name Model Model Model Model 5-025 5-050 5-075

More information

Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation Product Data Sheet May 2014 00813-0100-4801, Rev SA Rosemount 3051S Series of Instrumentation Scalable pressure, flow, and level solutions Innovation reaching across your operation With the Rosemount 3051S

More information

Thermocouple Without thermowell Model TC10-H

Thermocouple Without thermowell Model TC10-H Temperature Thermocouple Without thermowell Model TC10-H WIKA data sheet TE 65.08 for further approvals see page 2 Applications For direct installation into the process Machine building Motors Bearing

More information

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Resistance thermometer Model TR10-L, Ex d, for additional thermowell Electrical temperature measurement Resistance thermometer Model TR10-L, Ex d, for additional thermowell WIKA data sheet TE 60.12 for further approvals see page 6 Applications Chemical industry Petrochemical

More information

SRD998 Intelligent Positioner with HART Communication

SRD998 Intelligent Positioner with HART Communication Product Specifications 08.2016 -v4 PSS EVE0108 A-(en) SRD998 Intelligent Positioner with HART Communication The intelligent positioner SRD998 is designed to operate pneumatic valve actuators and can be

More information

Product Data Sheet , Rev GA Catalog Content

Product Data Sheet , Rev GA Catalog Content HIGHLY ACCURATE SMALL-BORE FLOW MEASUREMENT CAPABILITY WITH MINIMAL INSTALLATION AND MAINTENANCE REQUIREMENTS Improves accuracy and repeatability in 1 /2-in., 1-in., and 1 1 /2-in. line sizes Reduces leak

More information

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories Selection and Application Associated s T 8355 EN ff. Edition January 2010 Information Sheet T 8350 EN Positioners,

More information

Rosemount 1067 Compact Sensor and 1097 Thermowell

Rosemount 1067 Compact Sensor and 1097 Thermowell Product Data Sheet Rosemount 1067 and 1097 Rosemount 1067 Compact Sensor and 1097 Thermowell RTD and Thermocouple single and dual sensor models (1067 Model) Wide selection of materials available for thermowells

More information

Tubeskin thermocouple assembly Model TC59-V

Tubeskin thermocouple assembly Model TC59-V Electrical temperature measurement Tubeskin thermocouple assembly Model TC59-V WIKA data sheet TE 65.59 further approvals see page 7 V-PAD Applications Chemical industry Superheated steam applications

More information

Technical Datasheet. GR Series - Flameproof Pressure Switch Models: GR2 & GR4. GR Series. Key Features. Series Overview. Product applications

Technical Datasheet. GR Series - Flameproof Pressure Switch Models: GR2 & GR4. GR Series. Key Features. Series Overview. Product applications Technical Datasheet - Flameproof Pressure Switch Key Features Compact and rugged design. Weatherproof IP66/NEMA 4. ATEX Flameproof CENELEC EEx d IIC option. ATEX Intrinsically Safe ATEX Ex ia IIC option.

More information

Four Shaft Linear Thrusters

Four Shaft Linear Thrusters Four Shaft Linear Thrusters FOUR SHAFT THRUSTERS Three Models with bores from 2 to 4 Twice the load capacity of comparable two shaft units Reduced deflection and bearing play Compact, light weight robust

More information

The Product Range. Technical Data

The Product Range. Technical Data The Product Range Section 3.1 - Basic Cylinder Bore sizes (mm): 10, 16, 25, 32, 40, 50 The basic cylinder series satisfies the support and guidance requirements of a great diversity of applications. Various

More information

Rosemount DP Level Transmitters and 1199 Seal Systems

Rosemount DP Level Transmitters and 1199 Seal Systems Rosemount DP Level Transmitters and 1199 Seal Systems Product Data Sheet March 2015 Applications Level, Flow, Pressure, Interface, Density Extreme hot and cold temperatures Corrosive, clogging, or viscous

More information

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D Cl. I, Div. and 2, Groups B, C, D Cl. II, Div., Groups E, F, G Cl. II, Div. 2, Groups F, G Cl. III NEMA 3, 4, 4*,, Ex d IIB + H2 T, IP Explosionproof Dust-Ignitionproof Raintight Wet Locations Applications:

More information

SRD998 Intelligent Positioner (Version HART Basic Diagnostic)

SRD998 Intelligent Positioner (Version HART Basic Diagnostic) Quick Guide 07.2016 QG EVE0108 A-(en) SRD998 Intelligent Positioner (Version HART Basic Diagnostic) These instructions are to be used as a guide for quick start-up. For more detailed information please

More information

Linear Thrusters/PneuMoment

Linear Thrusters/PneuMoment /PneuMoment Extruded TE Series (Composite Bearings) 3.3-3.10 3.11-3.16 T Series Multiple Position T4 Series Movable Housing 3.17-3.22 3.23-3.24 3.25-3.28 3.29-3.32 Pneu-Moment Checklist PneuMoment Pneumatic

More information

Linear Thrusters/PneuMoment

Linear Thrusters/PneuMoment /PneuMoment Extruded 3.3-3.10 TE Series 3.11-3.16 T Series 3.17-3.22 3.23-3.24 3.25-3.28 3.29-3.32 PneuMoment Pneumatic Actuators PneuMoment Application 3.33 3.34-3.48 3.49 Bimba 304 stainless steel body

More information

Position Switches Series 8060/2

Position Switches Series 8060/2 www.stahl.de > Ex e plastic enclosure > Operating temperature range -60 to +60 C > Dimensions and characteristic values according to EN 50047 > Degree of protection IP66 / IP67 > Extensive assortment of

More information

Models 84F-T, 84F-U, and 84F-L (Style B) Flanged Body Flowmeters with HART Communications Protocol

Models 84F-T, 84F-U, and 84F-L (Style B) Flanged Body Flowmeters with HART Communications Protocol Parts List September 2018 I/A Series Intelligent Vortex Flowmeters Models 84F-T, 84F-U, and 84F-L (Style B) Flanged Body Flowmeters with HART Communications Protocol Give instrument Model Code when ordering.

More information

Linear Thrusters/PneuMoment

Linear Thrusters/PneuMoment /PneuMoment Extruded 3.3-3.10 TE Series 3.11-3.16 T Series 3.17-3.22 3.23-3.24 3.25-3.28 3.29-3.32 PneuMoment Pneumatic Actuators PneuMoment Application 3.33 3.34-3.48 3.49 Pneu-Moment Bimba Pneu-Moment

More information

Rosemount DP Flowmeters and Primary Elements

Rosemount DP Flowmeters and Primary Elements meters and Primary Elements Multivariable capabilities allow for real time fully compensated mass and energy flow Fully-Integrated Wireless Flowmeters allow for easy installation Minimize permanent pressure

More information

RTD Temperature Sensor omnigrad M- TR 11

RTD Temperature Sensor omnigrad M- TR 11 Technical Information TI 257T/02/en 60019736 RTD Temperature Sensor omnigrad M- TR 11 RTD assembly without extension neck With thermowell and replaceable insert PCP (4...20 ma), HART or PROFIBUS-PA electronics

More information

WedgeMaster FPD570 Compact wedge flowmeter. Combining durability with simplicity

WedgeMaster FPD570 Compact wedge flowmeter. Combining durability with simplicity Data sheet DS/FPD570 EN Rev. C WedgeMaster FPD570 Compact wedge flowmeter Combining durability with simplicity Compact flowmeter with integral transmitter, manifold and temperature element for volumetric-

More information

POSITIONERS and Controls for Complete Valve Automation

POSITIONERS and Controls for Complete Valve Automation CONTROLS A Division of AT Controls Pneumatic & Electro-Pneumatic POSITIONERS and Controls for Complete Valve Automation 1 SS SERIES SS Features Easy and quick auto-calibration Detecting RA (reverse acting)

More information

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J

Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J Electrical temperature measurement Threaded resistance thermometer With perforated thermowell model TW35 Model TR10-J WIKA data sheet TE 60.10 for further approvals see page 7 Applications Ventilation

More information

Series OCG Pneumatic Cylinders

Series OCG Pneumatic Cylinders New Models The Price Alternative Series OCG Pneumatic Cylinders www.phdinc.com (8) 624-811 and Rebuildable round body cylinders 6 bore sizes standard stroke lengths High speed/double acting OCG2 ORDERING

More information

Coriolis Flow Solutions for a Global Marketplace

Coriolis Flow Solutions for a Global Marketplace Coriolis Flow Solutions for a Global Marketplace www.tricorflow.com DECADES of EXPERIENCE = EXCEPTIONAL RESULTS When you combine decades of experience with truly unique talents, great things can happen.

More information

Resistance thermometer Without thermowell Model TR10-H

Resistance thermometer Without thermowell Model TR10-H Temperature Resistance thermometer Without thermowell Model TR10-H WIKA data sheet TE 60.08 for further approvals see page 2 Applications For direct installation into the process Machine building Motors

More information

Air Commander Part No , with air Part No , without air

Air Commander Part No , with air Part No , without air EASYSTREET Air Commander Part No. 27325, with air Part No. 27332, without air www.airliftcompany.com Please read these instructions completely before proceeding with installation. The oil level in the

More information

Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems

Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems Product Data Sheet March 2017 00813-0100-4016, Rev RD Applications Level, flow, pressure, interface, density Extreme hot and cold temperatures

More information

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell Electrical Temperature Measurement Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell WIKA Data Sheet TE 60.15 Applications T Machinery, plant and tank construction T Energy

More information

Description. Fieldbus Optimized Through Junction Boxes

Description. Fieldbus Optimized Through Junction Boxes Easy and safe connection for sensors, actuators and measuring instruments to the fieldbus - Foundation TM fieldbus, PROFIBUS-PA or HART Rugged assembly for industrial and hazardous areas Reduces wiring

More information

Safety Instructions Proline Promass 300

Safety Instructions Proline Promass 300 XA01472D/06/EN/01.16 71327890 Products Solutions Services Safety Instructions Proline Promass 300 Class I, Zone 1, AEx/Ex de ia IIC/IIB Class I, Zone 1, AEx/Ex d ia IIC/IIB Zone 21, AEx/Ex tb IIIC Txx

More information

Rosemount DP Flowmeters and Primary Elements

Rosemount DP Flowmeters and Primary Elements Product Data Sheet March 2015 00813-0100-4485, Rev FB Rosemount DP Flowmeters and Primary Elements Multivariable capabilities allow for real time fully compensated mass and energy flow Fully-Integrated

More information

Universal Instruction Manual. I/A Series Vortex Flowmeters Models 83F, 83W, and 83S

Universal Instruction Manual. I/A Series Vortex Flowmeters Models 83F, 83W, and 83S Instruction MI 019-145 June 2010 Universal Instruction Manual I/A Series Vortex Flowmeters Models 83F, 83W, and 83S Installation and Startup Safety information in many languages is available on our website.

More information

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS OSUR CL HA ES EN KILLARK Z LO C SJIC SERIES TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS Screw cover style, with or without continuous hinge 3/16 (5mm) wide flat flange for maximum gasket surface

More information

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE

More information

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc 900/77-80-094-001 158877 For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more compact, space-saving

More information

Rosemount DP Level Transmitters and 1199 Seal Systems

Rosemount DP Level Transmitters and 1199 Seal Systems Product Data Sheet FOR ROSEMOUNT 3051S, 3051, AND 2051 TRANSMITTERS APPLICATIONS Level, Flow, Pressure, Interface, Density Extreme hot and cold temperatures Corrosive, clogging, or viscous processes Hygienic

More information

Pivot Seal Pressure Switches for Fluid Power Applications

Pivot Seal Pressure Switches for Fluid Power Applications see more at SORInc.com Request Quote Pivot Seal for Fluid Power Applications SOR Pivot Seal pressure switches are rugged, field-mounted instruments that incorporate a flexible modular design providing

More information

Two Shaft Linear Thrusters

Two Shaft Linear Thrusters Two Shaft Linear Thrusters TWO SHAFT THRUSTERS Seven Models with bores from 9/16 to 4 Compact, light weight robust design Smooth linear motion CYLINDER Several manufacturers to choose from Pneumatic or

More information

New products Ex Equipment 2015

New products Ex Equipment 2015 New products Ex Equipment 2015 ROSE Systemtechnik GmbH ROSE Systemtechnik GmbH was founded in Porta Westfalica, Germany, in 199 and is today one of the world s leading and innovative providers of industrial

More information

Coriolis Flow Solutions for a Global Marketplace

Coriolis Flow Solutions for a Global Marketplace Coriolis Flow Solutions for a Global Marketplace www.tricorflow.com DECADES of EXPERIENCE = EXCEPTIONAL RESULTS When you combine decades of experience with truly unique talents, great things can happen.

More information

Rosemount DP Level Transmitters and 1199 Remote Seals

Rosemount DP Level Transmitters and 1199 Remote Seals Product Data Sheet FOR ROSEMOUNT 3051S, 3051, AND 2051 TRANSMITTERS APPLICATIONS Level, Flow, Pressure, Interface, Density Extreme hot and cold temperatures Corrosive, clogging, or viscous processes Hygienic

More information

Enclosures. Section E

Enclosures. Section E Enclosures Section E Enclosures and junction boxes built and configured to meet the requirements of the most demanding hazardous areas and industrial environmental applications across the globe. E Enclosures

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

TECHNICAL SUPPORT MANUAL Fan Coils

TECHNICAL SUPPORT MANUAL Fan Coils Fan Coils FEM4X, WAHM**4, WAHT**4 DANGER, WARNING, CAUTION, and NOTE The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL

More information

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see Technical data) Page 1/15 JUMO dtrans p20 Process pressure transmitter Brief description The device with the HART interface combines maximum precision with simple operation. It is used to measure the system pressure of

More information

PRESSURE, VAcuum, DIFFERENTIAL PRESSURE,

PRESSURE, VAcuum, DIFFERENTIAL PRESSURE, 12 S er i es 12 Se r i e s PRESSURE, VAcuum, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES PRESSURE, DIFFERENTIAL PRESSURE, AND TEMPERATURE SWITCHES DUAL SEAL CERTIFIED Features Compact 316 Stainless

More information

Level limit switch Series RF 3000 Selection list

Level limit switch Series RF 3000 Selection list Table of content Page Overview P2 Applications P4 ------------------------------------------------------------------------------------------------------------- RF 3100 Standard version P6 -------------------------------------------------------------------------------------------------------------

More information

AT100 Magnetostrictive Level Transmitter. High accuracy magnetostrictive liquid level transmitter K-TEK Products

AT100 Magnetostrictive Level Transmitter. High accuracy magnetostrictive liquid level transmitter K-TEK Products Data sheet DS/AT100-EN Rev. S AT100 Magnetostrictive Level Transmitter High accuracy magnetostrictive liquid level transmitter K-TEK Products Features SIL2 certified IEC 61508* High accuracy:.01% of full

More information