Flanged Body. Style A
|
|
- Bernadette Walton
- 5 years ago
- Views:
Transcription
1 Parts List PL June 2008 I/A Series Vortex Flowmeters Model 83F-D with FoxCom Communication Protocol Model 83F-T with HART Communication Protocol Model 83F-F with FOUNDATION Fieldbus Communication Protocol Model 83F-A with 4 to 20 ma Analog Output Flanged Body Style A *Parts preceded by an asterisk are recommended spare parts. Give Instrument Model Number and Style when ordering. See Recommended Spare Parts Summary section for quantities. TO ORDER PARTS, CALL INVENSYS SYSTEMS INC. AT
2 Page 2 MODEL CODE Model 83F Intelligent Vortex Flowmeters Flanged Body Description 83F = Intelligent Vortex Flowmeter Flanged Body Electronics Type D = Intelligent Electronics, FoxCom Communication Protocol T = Intelligent Electronics, HART Communication Protocol F = Intelligent Electronics, FOUNDATION Fieldbus Communication Protocol A = 4 to 20 ma Analog and Pulse Electronics Nominal Line Size 3Q = 3/4 in (DN 15) Line Size 01 = 1 in (DN 25) Line Size 1H = 1 1/2 in (DN 40) Line Size 02 = 2 in (DN 50) Line Size 03 = 3 in (DN 80) Line Size 04 = 4 in (DN 100) Line Size 06 = 6 in (DN 150) Line Size 08 = 8 in (DN 200) Line Size 10 = 10 in (DN 250) Line Size 12 = 12 in (DN 300) Line Size Body and Flange Material S = Sizes 3Q to 04: Cast Body/Flange and Shedder (except Code 04S1); CF 8M Material Size 04S1: Fabricated from 316 ss Tubing and Flanges Sizes 06 to 12: Body Fabricated from 304 ss Tubing with 304 ss Flanges K = Sizes 06 to 12: Body Fabricated from 304 ss Tubing with Carbon Steel (A105) Flanges End Connections and Flange Rating Description Used with Line Sizes 1 = ANSI Class 150 Flange, RF, per ASME B16.5 All line sizes 2 = ANSI Class 300 Flange, RF, per ASME B16.5 All line sizes 3 = ANSI Class 600 Flange, RF, per ASME B16.5 Sizes 3Q through 08 only 4 = Metric PN 16 Flange, RF, Finish Form D, per ASME B16.5 Sizes 06 through 08 only 5 = Metric PN 40 Flange, RF, Finish Form D, per DIN 2501 All line sizes 6 = Metric PN 64 Flange, RF, Finish Form E, per DIN 2501 Sizes 02 through 12 only 7 = Metric PN 100 Flange, RF, Finish Form E, per DIN 2501 Sizes 3Q through 08 only 8 = Metric PN 40 Flange, RF, Finish Form C, per DIN 2501 Sizes 3Q through 04 only A = Metric PN 40 Flange, RF, Finish Form N, per DIN 2501 All line sizes B = Metric PN 64 Flange, RF, Finish Form N, per DIN 2501 Sizes 02 through 12 only C = Metric PN 100 Flange, RF, Finish Form N, per DIN 2501 Sizes 3Q through 08 only D = Metric PN 16 Flange, RF, Finish Type B1, per EN Sizes 06 through 08 only (e) F = Metric PN 40 Flange, RF, Finish Type B1, per EN All line sizes (e) H = Metric PN 100 Flange, RF, Finish Type B1, per EN All line sizes (e) Single or Dual Measurement, Isolation Valve, and Manifold S = Single Measurement; No Isolation Valve D = Dual Measurement; Manifold with no Isolation Valve K = Single Measurement, Manifold with one Isolation Valve; CF 8M Stainless Steel L = Dual Measurement, Manifold with two Isolation Valves; CF 8M Stainless Steel Sensor Fill, Temperature Range, and Material Range (with Fill Fluid) D = Fluorolube Fill, 0 to 200 F ( 20 to +90 C) Hastelloy Type CW2M F = Fluorolube Fill, 0 to 200 F ( 20 to +90 C) Stainless Steel Type CF3M R = Silicone Fill, 0 to 400 F ( 20 to +200 C) Hastelloy Type CW2M S = Silicone Fill, 0 to 400 F ( 20 to +200 C) Stainless Steel Type CF3M Extended Temperature Range (No Fill Fluid) (d) C = Unfilled, 400 to 800 F (200 to 430 C) Hastelloy Type CW2M T = Unfilled, 400 to 800 F (200 to 430 C) Stainless Steel Type CF3M Model 83F Code continued on next page
3 Page 3 MODEL CODE (Cont.) Model 83F Intelligent Vortex Flowmeters - Flanged Body (Cont.) Electronics Housing Mounting, Material, and Conduit Connections T = Mounted to Flowtube; Aluminum Housing; 1/2 NPT Conduit Connections (a) R = Remote Mounted; Aluminum Housing; 1/2 NPT Conduit Connections (a) Also must select Cable Length in Options Section. Local Digital Indicator/Configurator or Analog/Pulse Output Indicator N = No Digital Indicator/Configurator or Output Indicator (Blind Unit) J = Digital Indicator/Configurator, Full Function - for Electronics Types -D, -T, and -F only A = Analog Output Indicator (4 to 20 ma); Electronics Type -A only. B = Analog Output Indicator, 10-Division Custom Scale per Sales Order; Electronics Type -A only. (f) E = Pulse Output Indicator; Electronics Type -A only. D = Pulse Output Indicator, 10-Division Custom Scale per Sales Order; Electronics Type -A only. (f) Electrical Safety A = CSA intrinsically safe, Division 1 (not available with Electronics Type -F). CSA explosionproof, Division 1. CSA suitable for Class I, II, and III, Division 2 (not available with Electronics Type -F). FM intrinsically safe, Division 1 (not available with Electronics Type -F). FM explosionproof, Division 1. FM nonincendive, Class I, II, and III, Division 2 (not available with Electronics Type -F). E = ATEX intrinsically safe, II 2 G, EEx ib IIC (not available with Electronics Type -F). N = ATEX protection n, II 3 G, EEx nl IIC (not available with Electronics Type -F). Z = No Approval/Certification Required. Optional Selections Cable Length Selection for Remote Electronics Housing B = 20 ft (6 m) Cable to Connect to Remote Electronics Housing D = 30 ft (9 m) Cable to Connect to Remote Electronics Housing E = 40 ft (12 m) Cable to Connect to Remote Electronics Housing G = 50 ft (15 m) Cable to Connect to Remote Electronics Housing Cleaning for Oxygen or Chlorine Service H = Cleaning of Process Wetted Parts for Oxygen/Chlorine Service per CGA G 4.1 and ASTM G93 (Not with Measurement/Isolation Valve Codes D, K, and L, Size Codes 10 and 12, or extended temperature Sensor Codes C and T) Sensor Plating J = Gold Plated Sensor Foxboro Certificates of Compliance/Conformance L = Standard Certificate of Compliance (ISO 9001) M = Foxboro Material Certification of Process Wetted Metal (BS EN ) Q = Process Wetted Parts Conform to NACE MR-01 Foxboro Certified Calibration Certificate N = Foxboro Calibration and Pressure Test Certification Cable Connections - with Electrical Housing Codes T and R (1/2 NPT) P = Hawke-Type Cable Gland (with Electrical Safety Codes E and Z only) R = PG11 Trumpet Gland (not with flameproof/explosionproof certifications) S = PG13.5 Trumpet Gland (not with flameproof/explosionproof certifications) Welding Certificate (Size Codes 06 through 12 only) (b)(c) F = Welding Certified to the ASME Boiler Code V = Radiographic Examination of Flange Welds (except ANSI 150 and Metric PN 16) X = Welding Certified to the ASME Boiler Code; includes Radiographic Examination Examples: 83F D02S1SDTNA X; 83F T06K7DCRJE GQNX (a) ATEX intrinsically safe certifications not available with 1/2 NPT openings. (b) Select one certificate only. Note that Certificate X includes both F and V certifications. (c) Not available when Size Code 06 or 08 is combined with End Connection Code 1 or 4. (d) Application ALERT: for Extended Temperature Range sensors used in hazardous or volatile gas applications, there is the potential of fugitive emissions to occur through the sensor vented restrictor if the sensor diaphragm were to fail. (e) Contact Invensys if metric flanges per EN are selected. (f) Ten equally spaced divisions; Customer specifies legend and marking.
4 Page 4 INTEGRALLY MOUNTED FLOWMETER ASSEMBLY (Figure 1) 83F-D, -T, AND -F DIGITAL DISPLAY/CONFIGURATOR F-A ANALOG INDICATOR WITH DIGITAL DISPLAY/CONFIGURATOR OR ANALOG INDICATOR F-D, -T, AND -F DIGITAL ELECTRONICS F-D, -T, AND -F DIGITAL ELECTRONICS F-A ANALOG ELECTRONICS F-A ANALOG ELECTRONICS EXTENDED TEMPERATURE RANGE METER STANDARD TEMPERATURE RANGE METER 8
5 Page 5 FLOWMETER ASSEMBLY WITH ISOLATION VALVING (Figure 2) (Also see Figure 1 for Items 10 and 11 without Isolation Valving) Item Part No. Qty. Part Name Below 1 Instruction Manual MI Analog Amplifier (83F A) MI Digital Electronics (83F D), FoxCom Communication MI Digital Electronics (83F T), HART Communication MI Digital Electronics (83F F), FOUNDATION fieldbus Communication 1 B0139CA 1 Plug, Pipe 2 Item 2 is intentionally not used. 3 Note 1 1 Housing Assembly (See Note 1) *4 Below 1 Amplifier and Digital Electronic Module Kit B0194RF Analog Amplifier Kit K0147DZ Digital Electronic Kit, FoxCom Communication K0147HX Digital Electronic Kit, HART Communication K0147VN Digital Electronic Kit, FOUNDATION fieldbus Communication 5 Below 2 Screw, Captive B0138ZY For Analog Amplifier X0173RH For Digital Electronic Modules 6 N0139FR Cable Tie 7 Note 1 1 Bonnet (See Note 1) *8 Below 1 Sensor Replacement Kit (See Note 2) K0148KV Sensor Type D (Hastelloy C with Fluorolube Fill) K0148KU Sensor Type F (316 ss with Fluorolube Fill) K0148KS Sensor Type R (Hastelloy C with Silicone Fill) K0148KR Sensor Type S (316 ss with Silicone Fill) K0148KY Sensor Type C (Hastelloy C, Extended Range) K0148KX Sensor Type T (316 ss, Extended Range) 9 Note 2 1 Sensor (See Note 2) 10 Below 1 Flow Dam (See Note 2) L0112KT K0146HK Extended Temperature (ss) K0146PU Extended Temperature (Hastelloy) 11 Below 1 Gasket (See Note 2) L0121DT K0146HL Extended Temperature (ss) K0146PT Extended Temperature (Hastelloy) 12 Below 1 O-Ring (See Note 2) D0100RP K0147CC Extended Temperature
6 Page 6 FLOWMETER ASSEMBLY WITH AND WITHOUT ISOLATION VALVING (Figures 1 and 2) (Cont.) Item Part No. Qty. Part Name 13 1 Flowtube (See Note 3) 14 X0173MC 4 Bolt (ASTM A193, Grade B7); x 1.5 in 15 B0138QV 2 Cover, Standard 16 Lubricant (See Note 4) *17 B0138QU 2 O-Ring, Cover 18 B0138QZ 2 Cover (for use w/indicator or Display) 19 Below 1 Indicator or Digital Display/Configurator B0138YM Analog Indicator (4 to 20 ma dc) B0135PA Indicator (Pulse Output 12.5 to 100 Hz) B0135PB Indicator (Pulse Output 90 to 400 Hz) B0135PC Indicator (Pulse Output 360 to 1600 Hz) B0135PD Pulse (1440 to 5000 Hz) K0147EK Digital Display/Configurator Kit 20 Below 1 Isolation Manifold B0194VZ (15 to 80 mm [3/4 to 3 in]) B0194WA (100 to 300 mm [4 to 12 in]) B0194WF Extended Temperature (15 to 80 mm [3/4 to 3 in]) B0194WG Extended Temperature (100 to 300 mm [4 to 12 in]) 21 X0173MC 4 Bolt (ASTM A193, Grade B7), x 1.5 in *22 K0146QG 1 Preamplifier Replacement Kit (not shown see Note 7) 23 K0146HP 1 Amplifier Calibration Cable (Option -C) 24 B0139DP 1 Pad, Restraining 25 X0171ZY 1 Nut, N7141HX 1 Hawke Cable Gland (Option -P) 27 N7000AA 1 PG11 Trumpet Gland Connector (Part of Option -R; Note 5) 28 N7141KR 1 PG11 Trumpet Gland (Part of Option -R; Note 5) 29 N7141DW 1 PG13.5 Trumpet Gland Connector (Part of Option -S; Note 6) 30 N7141KC 1 PG13.5 Trumpet Gland (Part of Option -S; Note 6) NOTE 1. This part is not usually replaced. Contact Invensys for replacement parts. 2. Items 9, 10, 11, and 12 are included in the Sensor Replacement Kit (Item 8, Figure 1). 3. Flowtubes are not user replaceable. Return entire Flowmeter to Invensys Systems for repair or replacement and recalibration. 4. Lubricate threads when replacing indicated items with a good commercially available lubricant. 5. Order Items 27 and 28 together as a set. These items are not shown. 6. Order Items 29 and 30 together as a set. These items are not shown. 7. The preamplifier replacement kit includes cable ties, screws, and instructions.
7 Page 7 REMOTE MOUNTED CONFIGURATION (Figure 3) FLOWMETER BODY Item Part No. Qty. Part Name Nut, D0114SM 1 U-Bolt (Not shown) 3 L0112DA 1 Connector, Remote Housing; ss 4 K0146JV 2 Bushing, Silicone Rubber 5 B0185AK 2 Nut, Knurled; ; ss 6 B0185AJ 1 Adapter; ss *7 Below 1 Cable, Remote Mounting K0146JL 6.1 m (20 ft) Long K0146JM 9.1 m (30 ft) Long K0146JN 12.2 m (40 ft) Long K0146JP 15.2 m (50 ft) Long *8 Below 1 Sensor Replacement Kit (Not shown, see Figure 1 and Note 1) K0148KV Sensor Type D (Hastelloy C with Fluorolube Fill) K0148KU Sensor Type F (316 ss with Fluorolube Fill) K0148KS Sensor Type R (Hastelloy C with Silicone Fill) K0148KR Sensor Type S (316 ss with Silicone Fill) K0148KY Sensor Type C (Hastelloy C, Extended Range) K0148KX Sensor Type T (316 ss, Extended Range)
8 Page 8 REMOTE MOUNTED CONFIGURATION (Figure 3) (Cont.) Item Part No. Qty. Part Name 9 Note 1 1 Sensor (Not shown, see Figure 1 and Note 1) 10 Below 1 Flow Dam (Not shown, see Figure 1 and Note 1) L0112KT K0146HK Extended Temperature (ss) K0146PU Extended Temperature (Hastelloy) 11 Below 1 Gasket (Not shown, see Figure 1 and Note 1) L0121DT K0146HL Extended Temperature (ss) K0146PT Extended Temperature (Hastelloy) 12 Below 1 O-Ring (Not shown, see Figure 1 and Note 1) D0100RP K0147CC Extended Temperature 13 Note 1 A/R Lubricant (See Note 2) 14 B0139CA 1 Plug, Pipe 15 Item 15 is intentionally not used. 16 X0173MC 4 Bolt (ASTM A193, Grade B7) x 1.5 in 17 Note 2 1 Bonnet (See Note 3) *18 K0146QG 1 Preamplifier Replacement Kit (See Note 4) *19 N0138MZ 1 O-Ring, Cover (Not shown) 20 L0112DE 1 Mounting Bracket Assembly NOTE 1. Items 9, 10, 11, and 12 are included in Sensor Replacement Kit (Item 8, Figure 1). 2. Lubricate threads when replacing indicated items with a good commercially available lubricant. 3. This part is not usually replaced. Contact Invensys Systems for replacement parts. 4. The preamplifier replacement kit includes cable ties, screws, and instructions).
9 Page 9 DUAL MEASUREMENT FLOWMETER (Figure 4) (Shown with Range Sensors) (SHOWN WITH STANDARD TEMPERATURE RANGE SENSORS)
10 Page 10 DUAL MEASUREMENT FLOWMETER (Figure 4) (Cont.) (Shown with Range Sensors) Item Part No. Qty. Part Name Below 1 Instruction Manual MI Analog Amplifier (83F A) MI Digital Electronics (83F D), FoxCom Communication MI Digital Electronics (83F T), HART Communication MI Digital Electronics (83F F), FOUNDATION fieldbus Communication 1 B0139CA 2 Plug, Pipe (Not shown) 2 Item 2 is intentionally not used. 3 Note 1 2 Housing Assembly (See Note 1) *4 Below 2 Amplifier and Digital Electronic Module Kit (Not shown) B0194RF Analog Amplifier Kit K0147DZ Digital Electronic Kit, FoxCom Communication K0147HX Digital Electronic Kit, HART Communication K0147VN Digital Electronic Kit, FOUNDATION fieldbus Communication 5 Below 2 Screw, Captive (Not shown) B0138ZY For Analog Amplifier X0173RH For Digital Electronic Module 6 N0139FR 4 Cable Ties 7 Note 1 2 Bonnet (See Note 1) *8 Below 2 Sensor Replacement Kit (See Note 2) K0148KV Sensor Type D (Hastelloy C with Fluorolube Fill) K0148KU Sensor Type F (316 ss with Fluorolube Fill) K0148KS Sensor Type R (Hastelloy C with Silicone Fill) K0148KR Sensor Type S (316 ss with Silicone Fill) K0148KY Sensor Type C (Hastelloy C, Extended Range) K0148KX Sensor Type T (316 ss, Extended Range) 9 Below 2 O-Ring (See Note 2) D0100RP K0147CC Extended Temperature 10 Note 2 Sensor (See Note 2) 11 Below 2 Flow Dam (See Note 2) L0112KT K0146HK Extended Temperature (ss) K0146PU Extended Temperature (Hastelloy) 12 Below 2 Gasket (See Note 2) L0121DT K0146HL Extended Temperature (ss) K0146PT Extended Temperature (Hastelloy)
11 Page 11 DUAL MEASUREMENT FLOWMETER (Figure 4) (Cont.) (Shown with Range Sensors) Item Part No. Qty. Part Name 13 Note 1 1 Flowtube (See Note 3) 14 Below 8 Bolt (ASTM A193, Grade B7) X0173MC x 1.5 in; with Dual Measurement Code D. X0173TF x 2.5 in; with Dual Measurement Code L. 15 B0138QV 4 Cover, Standard 16 Note 2 Lubricant (See Note 4) *17 B0138QU 4 O-Ring, Cover 18 B0138QZ 2 Cover (for use w/indicator or Display [Not shown]) 19 Below 2 Indicator or Digital Display/Configurator (Not shown) B0138YM Analog Indicator (4 to 20 ma) B0135PA Indicator (Pulse Output 12.5 to 100 Hz) B0135PB Indicator (Pulse Output 90 to 400 Hz) B0135PC Indicator (Pulse Output 360 to 1600 Hz) B0135PD Pulse (1440 to 5000 Hz) K0147EK Digital Display/Configurator Kit 20 Below 4 Bolt (ASTM A193, Grade B7) X0173MC x 1.5 in; with Dual Measurement Code D. X0173SV x 2.0 in; with Dual Measurement Code L. 21 Note 3 Dual Manifold (See Note 5) 22 Below 1 Stabilizer Bracket K0147DB for Dual Meter K0146HL for Extended Temperature Dual Meter NOTE 1. This part is not usually replaced. Contact Invensys for replacement parts. 2. Items 9, 10, 11, and 12 are included in the Sensor Replacement Kit (Item 8). 3. Flowtubes are not user replaceable. Return entire Flowmeter to Invensys Systems for repair or replacement and recalibration. 4. Lubricate threads when replacing indicated items with a good commercially available lubricant. 5. This part is not usually replaced. Contact Invensys for replacement parts.
12 Page 12 DUAL FLOWMETER REMOTE CONFIGURATION (Figure 5) (Shown with Extended Temperature Range Sensors) (SHOWN WITH EXTENDED TEMPERATURE RANGE SENSORS) FLOWMETER BODY
13 Page 13 DUAL FLOWMETER REMOTE CONFIGURATION (Figure 5) (Cont.) (Shown with Extended Temperature Range Sensors) Item Part No. Qty. Part Name Nut, D0114SM 1 U-Bolt (Not shown) 3 L0112DA 2 Connector, Remote Housing; ss 4 K0146JV 4 Bushing, Silicone Rubber 5 B0185AK 4 Nut, Knurled; ; ss 6 B0185AJ 2 Adapter; ss *7 Below 2 Cable, Remote Mounting K0146JL 6.1 m (20 ft) Long K0146JM 9.1 m (30 ft) Long K0146JN 12.2 m (40 ft) Long K0146JP 15.2 m (50 ft) Long 8 Note 1 A/R Lubricant (See Note 1) 9 B0139CA 1 Plug, Pipe 10 Item 10 is intentionally not used. 11 X0173MC 4 Bolt (ASTM A193, Grade B7) x 1.5 in 12 Note 2 Bonnet (See Note 2) *13 K0146QG 1 Preamplifier Replacement Kit (See Note 3) *14 N0138MZ 1 Cover Gasket (not shown) 15 Below 8 Bolt (ASTM A193, Grade B7) X0173MC x 1.5 in; with Dual Measurement Code D. X0173TF x 2.5 in; with Dual Measurement Code L. 16 Below 2 Sensor Replacement Kit (See Note 4) K0147BZ Sensor Type D K0147BX Sensor Type F K0147BY Sensor Type R K0147BW Sensor Type S K0147AV Sensor Type C B0194QX Sensor Type T
14 Page 14 DUAL FLOWMETER REMOTE CONFIGURATION (Figure 5 ( Cont.) Item Part No. Qty. Part Name 17 Below 4 O-Ring (See Note 4) D0100RP for K0147CC for Extended Temperature 18 Note 1 Sensor (See Note 4) 19 Below 2 Flow Dam (See Note 4) L0112KT for K0146HK for Extended Temperature (ss) K0146PU for Extended Temperature (Hastelloy) 20 Below 2 Gasket (See Note 4) L0121DT for K0146HL for Extended Temperature (ss) K0146PT for Extended Temperature (Hastelloy) 21 Below 4 Bolt (ASTM A193, Grade B7) X0173MC x 1.5 in; with Dual Measurement Code D. X0173SV x 2.0 in; with Dual Measurement Code L. 22 Note 2 Dual Manifold (See Note 5) 23 K0147DD 2 U-Bolt (Extended Temperature only) 24 K0142KX 4 Nut (Extended Temperature only) 25 K0147DC 1 Stabilizer Bracket (Extended Temperature only) 26 L0112DE 1 Mounting Bracket Assembly 27 Note 6 1 Flowtube (See Note 6) NOTE 1. Lubricate threads when replacing indicated items with a good commercially available lubricant. 2. This part is not usually replaced. Contact Invensys for replacement parts. 3. The preamplifier replacement kit includes cable ties, screws, and instructions. 4. Items 17, 18, 19, and 20 are included in the Sensor Replacement Kit. 5. This part is not usually replaced. Contact Invensys Systems for replacement parts. 6. Flowtubes are not user replaceable. Return entire flowmeter to Invensys for repair or replacement and calibration.
15 Page 15 Figure Number Item Number RECOMMENDED SPARE PARTS SUMMARY Part Number 1 and 4 4 Below B0194RF K0147DZ K0147HX K0147VN 8 Below K0148KV K0148KU K0148KS K0148KR K0148KY K0148KX Part Name Amplifier and Digital Electronic Module Kit Analog Amplifier Kit Digital Electronic Kit, FoxCom Digital Electronic Kit, HART Digital Electronic Kit, Fieldbus Sensor Replacement Kit Sensor Type D, Hast. C. w/fluorolube Fill Sensor Type F, 316 ss w/fluorolube Fill Sensor Type R, Hast. C. w/silicone Fill Sensor Type S 316 ss w/silicone Fill Sensor Type C, Hast. C, Extended Range Sensor Type T, 316 ss, Extended Range Number of Parts Recommended for 1 Inst. 5 Inst. 20 Inst B0138QU O-Ring, Cover K0146QG Preamplifier Replacement Kit (Universal) and 5 Item 18 on K0146QG Preamplifier Replacement Kit (Universal) Figure 3 and Item 13 on Figure 5 Item 19 on Figure 3 and Item 14 on Figure 5 N0138MZ O-Ring, Cover 0 1 2
16 Page Commercial Street Foxboro, MA United States of America Inside U.S.: Outside U.S.: or contact your local Foxboro representative. Facsimile: Invensys, Foxboro, FoxCom, and I/A Series are trademarks of Invensys plc, its subsidiaries, and affiliates. All other brand names may be trademarks of their respective owners. Copyright Invensys Systems, Inc. All rights reserved MB 150 Printed in U.S.A. 0608
Foxboro Model 84C Vortex Flowmeters Flanged Body Flowmeters
Parts List PL 008-754 June 2015 Foxboro Model 84C Vortex Flowmeters Flanged Body Flowmeters Give instrument Model Code when ordering. *Parts preceded by an asterisk are recommended spare parts. See Recommended
More informationFoxboro Model 83F Flanged Body Vortex Flowmeters Foxboro Model 83W Wafer Body Vortex Flowmeters with 4 to 20 ma Analog and Pulse Outputs
Product Specifications Foxboro Model 83F Flanged Body Vortex Flowmeters Foxboro Model 83W Wafer Body Vortex Flowmeters with 4 to 20 ma Analog and Pulse Outputs PSS 1-8A1 D 83W 83F 83F STANDARD TEMPERATURE
More informationModels 84F-T, 84F-U, and 84F-L (Style B) Flanged Body Flowmeters with HART Communications Protocol
Parts List September 2018 I/A Series Intelligent Vortex Flowmeters Models 84F-T, 84F-U, and 84F-L (Style B) Flanged Body Flowmeters with HART Communications Protocol Give instrument Model Code when ordering.
More informationBest Accuracy Under Operating Conditions. Specifications. Ordering. Length +/ " (3.2mm) Size. 1 MNPT mm 2 MNPT
Best Accuracy Under Operating Conditions Specifications Ordering Size Length +/- 0.125" (.2mm) 1 MNPT 4 101.6mm 2 MNPT 6 152.4mm Parts List PL 008-75 June 201 I/A Series Intelligent Vortex Flowmeters Models
More informationPSS 1-8A3 A NEED NEW PHOTO
Product Specifications I/A Series Intelligent Vortex Flowmeters Foxboro Model 84F Flanged Body Flowmeters and Foxboro Model 84W Wafer Body Flowmeters with HART Communication Protocol PSS 1-8A3 A NEED NEW
More informationProduct Specifications PSS 1-8A3 A NEED NEW PHOTO
Product Specifications I/A Series Intelligent Vortex Flowmeters Foxboro Model 84F Flanged Body Flowmeters and Foxboro Model 84W Wafer Body Flowmeters with HART Communication Protocol PSS 1-8A3 A NEED NEW
More informationFoxboro. FIELD DEVICES - FLOW Product Specifications PSS 1-8A3 A NEED NEW PHOTO
FIELD DEVICES - FLOW Product Specifications Logo PSS 1-8A3 A Models 84F and 84W Flanged and Wafer Body Flowmeters with HART Communication Protocol NEED NEW PHOTO The Foxboro brand I/A Series Models 84F
More informationModels 84F (Flanged Body, Style A) and 84W (Wafer Body) I/A Series Intelligent Vortex Flowmeters with HART Communication Protocol
FIELD DEVICES FLOW Product Specifications PSS 1-8A3 A Models 84F (Flanged Body, Style A) and 84W (Wafer Body) I/A Series Intelligent Vortex Flowmeters with HART Communication Protocol The Foxboro brand
More informationModel CO Compact Orifice for use with Foxboro Differential Pressure Transmitters
Product Specifications Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters PSS 3-5A1 E MODEL CO WITH TRADITIONAL STRUCTURE MODEL CO WITH LOW PROFILE STRUCTURE (LP1) MODEL CO
More informationFIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications
FIELD DEVICES - FLOW Product Specifications Logo 9100A Series Magnetic Flowtubes with Ebonite Liners 1 to 78 in (25 to 2000 mm) Nominal Flowtube Sizes The Foxboro brand 9100A Series Magnetic Flowtube together
More information84F STANDARD TEMPERATURE
FIELD DEVICES FLOW Product Specifications PSS 1-8A6 A LOW POWER Models 84F (Flanged Body, Style A), 84W (Wafer Body), and 84S (Sanitary) I/A Series Intelligent Vortex Flowmeters with HART Communication
More informationUniversal Instruction Manual. I/A Series Vortex Flowmeters Models 83F, 83W, and 83S
Instruction MI 019-145 June 2010 Universal Instruction Manual I/A Series Vortex Flowmeters Models 83F, 83W, and 83S Installation and Startup Safety information in many languages is available on our website.
More informationProduct Specifications PSS 1-8A1 F 83W 83F 83F
Product Specifications I/A Series Intelligent Vortex Flowmeters Foxboro Model 83F Flanged Body Flowmeters and Foxboro Model 83W Wafer Body Flowmeters with FOUNDATION Fieldbus Communication Protocol PSS
More informationFIELD DEVICES FLOW PSS 1-8A7 A. Product Specifications. Model 84F (Style B) Flanged Body Flowmeters with HART Communication Protocol FEATURES
FIELD DEVICES FLOW Product Specifications PSS 1-8A7 A Model 84F (Style B) Flanged Body Flowmeters with HART Communication Protocol The Foxboro brand I/A Series Model 84F Style B flanged vortex flowmeter
More informationIGP10, IGP20 Intelligent Gauge Pressure Transmitters IAP10 Intelligent Absolute Pressure Transmitter
, Intelligent Gauge Pressure Transmitters Intelligent Absolute Pressure Transmitter 1 for compact light weight and direct-to-process mounting (bracket optionally available), bracket mounted, for lower
More informationTRANSMITTER ATTACHES TO THIS SURFACE
FIELD DEVICES - PRESSURE Product Specifications Logo PSS 3-5A1 B Model IFOA Integral Flow Orifice Assembly Used with I/A Series or Pneumatic d/p Cell Transmitters PNEUMATIC TRANSMITTER TRANSMITTER ATTACHES
More informationRosemount 3051CFA Annubar Flowmeter
December 2013 Rosemount 3051 Rosemount 3051CFA Annubar Flowmeter The Rosemount 3051CFA Annubar Flowmeter utilizes the patented T-shaped sensor design that delivers best in class accuracy and performance.
More informationE83L (Styles A and B), E83W (Styles E, F and H), and E83F (Styles B, C, and D) Vortex Flowmeter
Instruction MI 019-166 March 1998 E83L (Styles A and B), E83W (Styles E, F and H), and E83F (Styles B, C, and D) Vortex Flowmeter Sensor/Amplifier Replacement E83L STYLES A ND B (FLANGED BODY SHOWN) E83W
More informationModel 84F Flanged and Male NPT Intelligent Vortex Flowmeters with HART Communication Protocol
FIELD DEVICES FLOW Product Specifications PSS 1-8A7 A Model 84F Flanged and Male NPT Intelligent Vortex Flowmeters with HART Communication Protocol The Foxboro brand Model 84F flanged and male NPT vortex
More informationFIELD DEVICES - PRESSURE
FIELD DEVICES - PRESSURE Product Specifications Logo Models IAP10, IGP10, IAP20, and IGP20 I/A Series Electronic Absolute and Gauge Pressure Transmitters with 4 to 20 ma Analog Output PSS 2A-1C13 C IAP20/IGP20
More informationRosemount 3051T In-Line Pressure Transmitter
Rosemount 3051T In-Line Pressure Transmitter Rosemount 3051T In-line Pressure Transmitters are the industry standard for Gage, and Absolute pressure measurement. The in-line, compact design allows the
More informationInstruction. MI June E69F Current-to-Pneumatic Signal Converter
Instruction MI 018-430 June 2005 E69F Current-to-Pneumatic Signal Converter ! DANGER This converter may have agency certification for installation in hazardous locations or for intrinsic safety. Use of
More information13DMP, Styles A and B and 13DEMP, Style A Pneumatic Transmitters
Parts List January 2003 13DMP, Styles A and B and 13DEMP, Style A Pneumatic Transmitters NOTE This list contains parts for servicing the pneumatic transmitter only. The sealed measurement system, if inoperative,
More information9300A Series Flanged Magnetic Flowtubes
Product Specifications 9300A Series Flanged Magnetic Flowtubes pfa Lined, 1 through 12 Inch; ptfe Lined, 1/2 through 16 Inch; Polyurethane Lined, 8 through 16 Inch PSS 1-6F4 A FEATURES pfa Withstands Effects
More informationUniversal Instruction Manual. I/A Series Vortex Flowmeters Models 83F, 83W, and 83S
Instruction MI 019-145 November 2003 Universal Instruction Manual I/A Series Vortex Flowmeters Models 83F, 83W, and 83S Installation and Startup For safety information in English, refer to the web site
More informationRosemount 3051 Pressure Transmitter
Product Data Sheet Rosemount 3051 Rosemount 3051 Pressure Transmitter THE PROVEN INDUSTRY LEADER IN PRESSURE MEASUREMENT Best-in-Class performance with up to 0.04% reference accuracy Industry first installed
More informationVortex Flowmeters VFM 3100 F-T VFM 3100 W-T
KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring
More informationRosemount 3051S Series of Instrumentation
Product Data Sheet January 2013 00813-0100-4801, Rev RA Rosemount 3051S Series of Instrumentation Scalable Pressure, Flow, and Level Solutions Innovation Reaching Across Your Operation With the Rosemount
More informationRosemount DP Flowmeters and Primary Elements
meters and Primary Elements Multivariable capabilities allow for real time fully compensated mass and energy flow Fully-Integrated Wireless Flowmeters allow for easy installation Minimize permanent pressure
More informationRosemount Engineered Assemblies
Product Data Sheet A single, high performance, engineered solution designed to meet the highest industry standards: Complete measurement solution, ready to install out of the box Designed and built to
More informationProduct Data Sheet , Rev GA Catalog Content
HIGHLY ACCURATE SMALL-BORE FLOW MEASUREMENT CAPABILITY WITH MINIMAL INSTALLATION AND MAINTENANCE REQUIREMENTS Improves accuracy and repeatability in 1 /2-in., 1-in., and 1 1 /2-in. line sizes Reduces leak
More informationFlow Measurement SITRANS F C
Overview The complete flowmeter system SITRANS FC40 can be ordered for standard, hygienic or NAMUR service. All versions can be ordered for CT service, according to OIML R 117 (Liquids other than water)
More informationRosemount 3051S Electronic Remote Sensor (ERS) System
Rosemount 3051S Electronic Remote Sensor (ERS) System The Rosemount 3051S ERS System is a flexible, 2-wire 4-20 ma ART architecture that calculates differential pressure (DP) electronically using two pressure
More informationRosemount 3051S Series of Instrumentation
Product Data Sheet May 2014 00813-0100-4801, Rev SA Rosemount 3051S Series of Instrumentation Scalable pressure, flow, and level solutions Innovation reaching across your operation With the Rosemount 3051S
More informationRosemount 3051 Pressure Transmitter
Rosemount 3051 Pressure Transmitter Product Data Sheet April 2014 00813-0100-4001, Rev RC With the Rosemount 3051 Pressure Transmitter, you ll gain more control over your plant. You ll be able to reduce
More informationBGN. All Metal Variable Area Flow Meter. Technical Data Sheet
All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of
More informationGeneral Specifications
General Specifications GS 22B01C05-00EN-A C13ST Manifolds for Traditional Mount Gauge and Absolute Pressure Transmitters Designed and manufactured by AS-Schneider, Yokogawa C13ST-2 2-Valve manifolds are
More information2010TC for Differential Pressure, Pressure and Temperature (Mass Flow)
Technical data 2 Principle of Operation and Construction The transmitter has a modular design and consists of the differential pressure sensor module with an integrated electronic matching unit, an amplifier
More information28000 Series Varipak Control Valves
GE Oil & Gas Technical Specifications 10/2012 Masoneilan * Valves 28000 Series Varipak Control Valves Precise Microflow Valves with Compact Design and Flexible Capabilities Table of Contents Numbering
More informationTHE ROSEMOUNT 8800C DELIVERS RELIABILITY Rosemount Reliability -The 8800C Vortex eliates impulse lines, ports, and gaskets to improve reliabil
E-MAIL: Vortex Flowmeter HART AND FOUNDATION FIELDBUS PROTOCOLS Available in wafer, flanged, dual, and reducer designs. Only manufacturer of Reducer Vortex which extends the measurable flow range, reduces
More informationFoxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element
Product Specifications Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element PSS 1-5A1 A MODEL 2761 MODEL 2781 The Foxboro Dew Point Measurement
More informationINTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter
INTERPLANT STANDARD - STEEL INDUSTRY IPSS Specification for Smart Pressure & Differential Pressure Transmitter Corresponding IS does not exist IPSS: 2-07-104-15 1. Scope 1.1 This Interplant Standard covers
More informationGeneral Specifications
General Specifications GS 22B01C06-01EN-A C13ST Manifolds for Traditional Mount Differential Pressure Transmitters Designed and manufactured by AS-Schneider, Yokogawa C13ST-3 and C13ST-5 manifolds are
More informationSmart Pressure Transmitter
DOC. NO.: C3500L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3500L 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,
More informationSmart Pressure Transmitter
DOC. NO.: C3100L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3100L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200
More informationRosemount 3051S Series of Instrumentation
Product Data Sheet 3051S Series delivers highest field performance and reliability SuperModule Platform provides a foundation for integrated pressure, flow, and level solutions IEC 62591 (WirelessHART
More informationValve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator
Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam Nominal size
More informationRosemount DP Level Transmitters and 1199 Seal Systems
Product Data Sheet FOR ROSEMOUNT 3051S, 3051, AND 2051 TRANSMITTERS APPLICATIONS Level, Flow, Pressure, Interface, Density Extreme hot and cold temperatures Corrosive, clogging, or viscous processes Hygienic
More informationI/A Series Intelligent Vortex Flowmeter Models 84F-T, 84F-U, 84W-T, and 84W-U With HART Communication
Instruction MI 019-202 April 2010 I/A Series Intelligent Vortex Flowmeter Models 84F-T, 84F-U, 84W-T, and 84W-U With HART Communication Installation, Operation, and Maintenance MI 019-202 April 2010 Contents
More informationVersaFlow Vortex 100 Vortex Flow Meter Specifications
VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.
More informationRosemount DP Flowmeters and Primary Elements
Product Data Sheet Rosemount DP Flowmeters and Primary Elements Rosemount DP Flow Multivariable capabilities allow for real time fully compensated mass and energy flow Fully-Integrated Wireless Flowmeters
More informationRosemount DP Level Transmitters and 1199 Remote Seals
Product Data Sheet FOR ROSEMOUNT 3051S, 3051, AND 2051 TRANSMITTERS APPLICATIONS Level, Flow, Pressure, Interface, Density Extreme hot and cold temperatures Corrosive, clogging, or viscous processes Hygienic
More informationKDM ARMORED FLOW METER & SWITCH
KDM ARMORED FLOW METER & SWITCH Flow Pressure Level Temperature measurement monitoring control S2 Short Installation Length SS, PTFE or Hastelloy Wetted Parts Analog Output Available 110 F to + 390 F Temperature
More informationRosemount DP Level Transmitters and 1199 Seal Systems
Rosemount DP Level Transmitters and 1199 Seal Systems Product Data Sheet November 2013 00813-0100-4016, Rev NA Applications Level, Flow, Pressure, Interface, Density Extreme hot and cold temperatures Corrosive,
More informationORIMAS Mass Flowmeter
Typical Applications ORIMAS Mass Flowmeter The ORIMAS mass flow meters measure the mass flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical
More informationJUMO dtrans p20 DELTA
Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision
More informationSATRON VDt Differential Pressure Transmitter
SATRON VDt differential pressure transmitter belongs to V-transmitter family. The series V transmitters have both analog and smart properties. SATRON VDt is used for -,1kPa...-15 MPa ranges. It is a 2-wire
More informationRosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications
Product Data Sheet Rosemount 3051 FIELDBUS PROTOCOL Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof
More informationUNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F
UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F DESCRIPTION The 100 Series is a cost-effective pressure and temperature
More informationPlastic tube variable area flowmeter for liquids and gases
Plastic tube variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or fusion welding connections)
More informationRosemount 3051S Series of Instrumentation
Product Data Sheet 00813-0100-4801, Rev UK December 2018 Rosemount 3051S Series of Instrumentation Innovation reaching across your operation With the Rosemount 3051S Series of Instrumentation, operations
More informationSTEEMCO Flowmeter for Steam
STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationDM2500 Series. Flanged Ball Valves SPECIFICATIONS ORDERING SCHEMATIC
DM2500 Series Flanged Ball Valves SPECIFICATIONS Available in stainless steel or carbon steel Body and ends are investment cast Self-adjusting stem packing Blow-out proof stem design 100% air tested under
More informationIFOA Integral Flow Orifice Assembly
Instruction MI 022-333 July 2007 Introduction IFOA Integral Flow Orifice Assembly The IFOA integral flow orifice assembly is used in conjunction with a Foxboro electronic or pneumatic differential pressure
More informationSITRANS F X SITRANS FX300 3/355
Siemens AG 204 Flow Measurement Overview vortex flowmeters provide accurate volumetric and mass flow measurement of steam, gases and liquids as an all-in-one solution with integrated temperature and pressure
More informationRosemount DP Level Transmitters and 1199 Diaphragm Seal Systems
Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems Product Data Sheet December 2017 00813-0100-4016, Rev RF Applications Level, flow, pressure, interface, density Extreme hot and cold temperatures
More informationMaterials : Forged carbon steel or stainless steel
Size : Ends : Min Temperature : Max Temperature : DN 15 to 200 mm ( 1/2" to 8" ) ISO PN50 ANSI 300 R.F. - 28 C + 200 C Max Pressure : 50 Bars Specifications : With ISO 5211 mounting pad Fire safe BS 6755-2
More informationSTEEMCO-MAS Flowmeter for Steam
STEEMCO-MAS Flowmeter for Steam Typical Applications The STEEMCO-MAS flow meters measure the mass flow of superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical
More informationModel 8800C Vortex Flowmeter
Vortex Flowmeter Start Step 1: Mount the Flowmeter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Review Flowmeter Configuration Product Certifications
More information3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4" and 1 /2" 5/2 Way Solenoid Valve 1 /4" 6/2 Way Solenoid Valve 1 /4" 5/3 Way Solenoid Valve 1 /4"
/2 Way Pilot Valve /2 Way Solenoid Valve 1 /" and 1 /2" 5/2 Way Solenoid Valve 1 /" 6/2 Way Solenoid Valve 1 /" 5/ Way Solenoid Valve 1 /" General The solenoid valves consist of one or two /2 way pilot
More informationVLM20 In-line Vortex Flowmeter
ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
More information83F-A, E83FA, 83W-A, and E83WA, Vortex Flowmeters
Instruction MI 019-189 March 2009 83F-A, E83FA, 83W-A, and E83WA, Vortex Flowmeters Installation, Troubleshooting, and Maintenance 83F-A - FLANGE BODY (EXTENDED TEMPERATURE FLANGE AND LOCAL INDICATOR)
More information94406 Vertical Inline Deflagration Flame Arrester. Features
94406 The Shand & Jurs 94406 Vertical Inline Deflagration Flame Arresters are designed to provide a positive flame stop on low pressure tanks or piping systems containing flammable liquids or solvents
More informationTemperature Measurement Resistance thermometers
Temperature transmitters for mounting in the connection head The following temperature transmitters are available for mounting in the connection head: SITRANS TH100 Programmable two-wire temperature transmitter
More informationRosemount DP Level Transmitters and 1199 Diaphragm Seal Systems
Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems Product Data Sheet March 2017 00813-0100-4016, Rev RD Applications Level, flow, pressure, interface, density Extreme hot and cold temperatures
More informationDifferential Pressure Gauges (701P Series)
Applications Equipped two Process Connections Indicating low and high pressure Measuring differential pressure as well as liquid or flow levels Recommended to use 3-way & 5-way valve manifold Pressure
More informationThe EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.
Typical Applications EPSILON Flowmeter The EPSILON flow meters measure the flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power
More informationGlass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases
Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases Easy installation Local indication by means of direct reading Low pressure drop Scales directly in l/h, m 3 /h, kg/h, l/min,
More informationRosemount 1195 Integral Orifice Primary Element
September 2014 Rosemount DP Flow Rosemount 1195 Integral Orifice Primary Element Rosemount 1195 Integral Orifice Primary Element utilizes a self centering orifice plate design to eliminate installation
More informationSmart Pressure Transmitter
DOC. NO.: C3200L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3200L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200
More informationDigital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.
Digital Vortex meter digitalyewflo Digital Vortex meter Series Bulletin 01F06A02-00E www.yokogawa.com/ Series Simple body construction for easy installation and high level of safety 2 3 Standard Type /
More informationMobrey MSM400 Ultrasonic sludge density measurement system
Technical specification sheet IP257 October 2008 Mobrey MSM400 Ultrasonic sludge density measurement system Level Features Measuring range up to 50% solids Simple keypad operation HMI menu based programming
More informationSeries Level-Trol Electronic Liquid Level Transmitters
0- Level-Trol Series 0- Series Level-Trol Electronic Liquid Level Transmitters W0-/IL Non-Interactive Zero and Span Adjustments; Dry Span Calibration Allows Field Recalibration without Removing Wiring
More informationJUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb
sales@jumo.co.uk info@jumo.us Data Sheet 404385 Page 1/6 JUMO dtrans p02 Pressure transmitter II 1/2G Ex ia IIC T6 Ga/Gb General application The pressure transmitter Type JUMO dtrans p02 is used to measure
More informationMobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter
Product Data Sheet February 2015 IP119, Rev CA Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting 4 20 ma HART output ATEX Intrinsically
More informationRef FIRE SAFE BALL VALVE ISO PN50 ANSI Model/Ref:
FIRE SAFE BALL VALVE ISO PN50 ANSI 300 Model/Ref: 768-769 www.lauridsenindustri.com Size : Ends : Min Temperature : Max Temperature : DN 15 to 200 mm ( 1/2" à 8 ) ISO PN50 ANSI300 R.F. Flanges -50 C in
More informationUser's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter
User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter Manual Change No. 09-001-5E Please use attached sheets for the pages listed below in (10th). Page Page 10-2 EMC Conformity
More information2 PIECES BALL VALVE PN63
2 PIECES BALL VALVE PN63 Model/Ref: 756-757 www.lauridsenindustri.com Size : Ends : Min Temperature : Max Temperature : DN 15 to 200 mm ( 1/2" à 8 ) ISO PN20 ANSI150 R.F. Flanges -50 C in SS and -29 C
More informationRosemount 8800D Series Vortex Flowmeter
Product Data Sheet HART AND FOUNDATION FIELDBUS PROTOCOLS Available with optional MultiVariable output and temperature compensated mass flow for saturated steam. Available in wafer, flanged, dual, reducer
More informationLevel Limit Switch liquiphant FTL 365 / FTL 366
Technical Information TI 86F/00/en Level Limit Switch liquiphant FTL 65 / FTL 66 Level limit switch Liquiphant II with vibrating probe. For all types of liquid. With explosionproof housing for use in hazardous
More informationRosemount 8800D Series Vortex Flowmeter
Product Data Sheet HART AND FOUNDATION FIELDBUS PROTOCOLS Available in wafer, flanged, dual, reducer and high pressure designs. Only manufacturer of Reducer Vortex which extends the measurable flow range,
More informationFIELD DEVICES PRESSURE
FIELD DEVICES PRESSURE Product Specifications I/A Series Electronic Pressure Transmitters Options and Accessories Foxboro I/A Series Pressure Transmitters are offered with a wide variety of features, options,
More informationRosemount DP Flowmeters and Primary Elements
Product Data Sheet March 2015 00813-0100-4485, Rev FB Rosemount DP Flowmeters and Primary Elements Multivariable capabilities allow for real time fully compensated mass and energy flow Fully-Integrated
More informationMasoneilan Series
Masoneilan 12300 Series Digital Level Transmitter & Controller Specification Data CU3000 02/02 Digital Level Measurement and Control Instrumentation Table of Contents General Description...2 Principle
More informationModel 261GC/GG/GJ/GM/GN Gauge Model 261AC/AG/AJ/AM/AN Absolute. Series 2600T Pressure Transmitters. Engineered solutions for all applications
Contents Data Sheet SS/261GC/AC-EN Rev. 05 Model 261GC/GG/GJ/GM/GN Gauge Model 261AC/AG/AJ/AM/AN Absolute Series 2600T Pressure Transmitters Engineered solutions for all applications With direct mount
More informationRosemount DP Level Transmitters and 1199 Seal Systems
Rosemount DP Level Transmitters and 1199 Seal Systems Product Data Sheet March 2015 Applications Level, Flow, Pressure, Interface, Density Extreme hot and cold temperatures Corrosive, clogging, or viscous
More informationMagnetic-inductive flow meter for hazardous areas
Magnetic-inductive flow meter for hazardous areas Technical Datasheet EPX / UMF3 high accuracy: 0.3 % of actual maintenance-free no pressure drop numerous lining materials numerous electrode materials
More informationSVF FLOW CONTROLS. Series # Flanged Standard Port Fire Safe / API th Edition. Performance Engineered I N C O R P O R A T E D
Series 41 150# Flanged Standard Port Fire Safe / API-607 4 th Edition 1 PIECE REDUCED PORT BALL VALVE UNITS = INCHES SIZE CLASS 150 WEIGHTS L H W 1 1/2 11 6.50 3.86 9.06 2 21 7.01 4.65 9.06 3 40 7.99 5.98
More informationSolenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
More informationSeries 3730 Electropneumatic Positioner Type
Series 3730 Electropneumatic Positioner Type 3730-1 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and