Series AN05 to 40 RoHS
|
|
- Leon McBride
- 5 years ago
- Views:
Transcription
1 Silencer Compact Resin Type/Male Thread N0 to 40 RoHS How to Order N 0 Body size Specifications Thread type M thread Nil R N NPT Thread connection port size pplicable model M M x 0.8 /8 /4 3/8 / N0 N0 N/ N30 N40 Fluid Max. operating pressure Note ) Noise reduction mbient and fluid temperature Compressed air 4psi (.0 MPa) 30 db() Note ) 4 to 40 F ( to 60ºC) Note 3) Note ) It indicates the inlet pressure for solenoid valve. Note ) The value may vary, depending on the pneumatic circuit or pressure that is exhausted from the solenoid valve. Note 3) The product can be used in temperatures 4 to 40 F ( 0 to 60 C) if there is no risk of water droplets forming and freezing. Refer to page for Precautions on these products. Performance Effective area mm Sonic conductance C [dm 3 /(s bar)] Recommended flow m 3 /min(nr) N0-M 0.4 or less N or less N or less N or less N or less N or less Note) Recommended flow rate is the flow at 7.psi (0. MPa) in the inlet pressure. Weight g Construction/Parts/imensions N0/0/ N/30/40 No hexagonal part in N0 and N0 Sound absorbing material (Resin sintered body) Body (Resin) Hexagonal flats imensions R, NPT N0-M M x 0.8 N0-0 /8 N-0 /4 N-0 /4 N /8 N40-04 / B (mm) 4 4 7
2 Silencer Compact Resin Type/One-touch Fitting Connection N0 to 30-C RoHS How to Order N C 0 C Specifications Body size 0 30 Connection type Connection type One-touch fitting connection pplicable one-touch fitting size pplicable model ø6 ø/4 ø8 ø0 ø3/8 ø N0 N0 N N N N30 Fluid Compressed air Max. operating pressure Note ) 4psi (.0 MPa) Noise reduction 30 db() Note ) mbient and fluid temperature 4 to 40 F ( to 60ºC) Note 3) Note ) It indicates the inlet pressure for solenoid valve. Note ) The value may vary, depending on the pneumatic circuit or pressure that is exhausted from the solenoid valve. Note 3) The product can be used in temperatures 4 to 40 F ( 0 to 60 C) if there is no risk of water droplets forming and freezing. Refer to page for Precautions on these products. Performance Effective area mm Sonic conductance C [dm 3 /(s bar)] Recommended flow m 3 /min(nr) N0-C06 N0-C or less N-C or less N-C or less N-C 3.0 or less N30-C or less Note) Recommended flow rate is the flow at 7.psi (0. MPa) in the inlet pressure. Construction/Parts/imensions Weight g N0-C to 30-C C ød Sound absorbing material (Resin sintered body) Body (Resin) imensions N0-C N0-C07 N-C08 4 N-C0 7. N-C N30-C 7. B 3 6. C (mm) ød ø6 ø/4 ø8 ø0 ø3/8 ø 3
3 Silencer Metal Body Type N 00 RoHS Noise reduction 30 db() Low back pressure Easy mounting N Body size How to Order Thread type Type Nil R N NPT pplicable model /4 /4 / N00 N600 N700 N800 N900 Specifications JIS Fluid Max. operating pressure Note ) Noise reduction mbient and fluid temperature Compressed air 4psi (.0 MPa) 30 db() Note ) 4 to 40 F ( to 60ºC) Note 3) Note ) It indicates the inlet pressure for solenoid valve. Note ) The value may vary, depending on the pneumatic circuit or pressure that is exhausted from the solenoid valve. Note 3) The product can be used in temperatures 4 to 40 F ( 0 to 60 C) if there is no risk of water droplets forming and freezing. Refer to page for Precautions on these products. Performance Effective area mm Sonic conductance C [dm 3 /(s bar)] N00-06 N600-0 N700- N800-4 N or less or less 30 or less 0 or less 80 or less Note) Recommended flow rate is the flow at 7.psi (0. MPa) in the inlet pressure. Construction/Parts/imensions Recommended flow m 3 /min(nr) Weight g N00 to 900 End plate (Carbon steel) Tension bolt (Carbon steel) Sound absorbing material (Resin sintered body) Cover (Carbon steel) Body (luminum alloy) Hexagonal flats imensions N00-06 N600-0 N700- N800-4 N900- R, NPT 3/4 /4 / B (mm)
4 N Specific Product Precautions Be sure to read before handling. Refer to back cover for Safety Instructions. Warning esign. The silencer clogging may result in a blocked exhaust port. Provide a safety design so as not to cause the whole system to malfunction.. The silencer is intended to reduce the noise of compressed air that is exhausted from the pneumatic equipment. Since noises generated by sources other than the exhaust, such as noise generated inside piping, equipment vibration and solenoid valve switching, cannot be reduced, locate the cause of these noises and take countermeasures. The product does not function as a filter. o not use the product as a filter regardless of negative and positive pressures.. If the compressed air supply is contaminated with fluids such as oil and oil mist, such fluids will be dispersed to the environment. In such a case, an exhaust cleaner is recommended to recover fluids and reduce noise. 3. The value of the noise reduction may vary, depending on the pneumatic circuit or pressure that is exhausted from the solenoid valve. Selection. When selecting the silencer, the sonic conductance (including combined sonic conductance) of the silencer should be larger than that of the solenoid valve. Sonic conductance C [dm 3 /(s bar)] = Effective area [mm ]. Use within the range of specifications. Operating Environment Warning. o not use in an atmosphere having corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. Refer to the construction drawings for silencer materials.. void exposure to direct sunlight. 3. o not operate in locations where vibration or impact occurs. 4. o not use the product in locations where it is near heat sources and exposed to radiation heat.. o not use in an environment where the product is exposed to cutting oil, lubricating oil, or coolant, etc. If it is used in an environment where there is possible contact with cutting oil, lubricating oil, or coolant, exercise preventive measures. 6. o not use in an environment where foreign matter may stick to the product or get mixed in the product s interior. It may result in clogging at an early stage, coming off or causing damage. Silencer Tightening Torque (Metal type) Connection thread R 3/4 R R /4 R / R Mounting. If the silencer body is made of resin and is tightened too much, the silencer may be damaged.. Tightening by using a pipe wrench or pliers may cause damage to the silencer. This method is not recommended. Please follow the procedures below for mounting. When the body is made of resin Hold the tip of the body (the side without thread) and screw it in. t the point where the thread begins to feel tight, use a wrench on the hexagonal flats to tighten an additional /4 turn. Tighten the N0-M by hand completely until the ends of the fitting come into contact with the mounting surface. Then apply additional tightening. Note that the additional tightening should be 30 or less. (Tighten it with 0. N m or less.) Silencer When the body is made of metal Within the recommended tightening torque shown in the table below, use a wrench on the hexagonal flats and tighten. pplicable tightening torque N m 8 to to to 4 48 to 0 48 to 0 3. Make sure not to apply a lateral load to the body during or after the installation. 4. When the silencer body is loosened by vibration, etc. of equipment on which a silencer is assembled, apply glue to threads to prevent loosening and reattach. Maintenance. The sound absorbing material is not replaceable. Since the sound absorbing material is not replaceable, never disassemble the product.. If the exhaust speed drops and the system performance decreases due to clogging, replace with a new silencer. Make sure to verify the operating conditions of the actuator at least once a day. 3. If operation continues when it is clogged, breakage can result.
5 Silencers/Exhaust Cleaner N / MC Noise reduction Nominal filtration rating (Reference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting N db () 00 µm 0 µm -0- Compact type Space-saving compact type N 03 db () 00 µm -0-3 Silencers Metal case type Exhaust in only one direction. Prevents scattering of mist and noise. BC sintered body type Ideal for the exhaust of a compact valve or pilot air. One-touch fitting connection type Can connect with One-touch fitting directly. N0-0 N0-0 N-M N-M3 N -KM 9 db () 6 db () db () 8 db () 3 db () db () 30 db () It differs depending upon the model. 00 µm 70 µm 00 µm VEX N MC High noise reduction type Case adopts UL94-V0 grade flame resistant material. N 0 3 db () 0 µm -0-7 High noise reduction type high noise reduction type silencer keeps the noise level inside a plant below 8 db (). N 40 db () 30 µm -0-8 High noise reduction type NB has a larger effective area with the same port size as N. NB 38 db () 30 µm -0-9 Exhaust Cleaner Exhaust cleaner Ensures clean plant air, reduces noise pollution by over 3 db (), and removes over 99.9% of all oil mist. MC 3 db () 0.3 µm 99.9% -0- Precautions/Specific Product Precautions -0-3 Related Products Exhaust Cleaner for Vaccum ( MV) Exhaust Cleaner for Clean Room ( MP)
6 .34 IR P REPRTION: CCESSORIES S ILENCERS S ERIES (N)N S ERIES (N)N SILENCER M3, M, 8 S INTERE B RONZE Suitable for miniature valves and pilot air exhaust ports 3 - db noise reduction T ECHNICL SPECIFICTIONS NN0-0 NN0-0 NN-M3 NN-M Port Size 8 * 8 * M3 M Noise Reduction (db) Max Operating Pressure MPa / 4PSI mbient & Fluid Temperature ~0 C / 40~300ºF Effective Orifice mm (Cv) (.) 3 (.9) (0.0) (0.7) Weight (gf) H O W T O O R E R SERIES NN SILENCER NN-M3 (M3) NN-M (M) NN0-N0 ( 8 NPT) NN0-N0 ( 8 NPT) *Tapered thread ISO7/ S Y M B O L S IMENSIONS SERIES NN SILENCER ØB H O W T O O R E R SERIES N SILENCER N-M3 (M3) N-M (M) N0-0 ( 8 PT) N0-0 ( 8 PT) NN0-N0. NN0-N NN-M3 9 6 NN-M 7 8 S ERIES (N)N SILENCER 4~ Over 30 db noise reduction Low back pressure Compact and easy mounting T ECHNICL SPECIFICTIONS S Y M B O L S Max Operating Pressure MPa / 4PSI Noise Reduction 30dB or more H O W T O O R E R SERIES NN SILENCER mbient & Fluid Temperature ~60 C / 40~40ºF Port Size* NPT Effective Orifice mm (Cv) NN0-N0 4 3 (.9) NN300-N (3.3) NN400-N04 90 (.0) NN00-N (8.8 NN600-N0 70 () NN700-N (4) NN800-N4 90 (33) NN900-N 960 (3) Note: When ordering PT Ports, remove (N) from Number Eg: N0-0 IMENSIONS SERIES NN SILENCER imensions (mm) B NN0-N NN300-N03 84 NN400-N NN00-N NN600-N NN700-N 0 74 NN800-N NN900-N FOR FURTHER TECHNICL ETILS ON THIS PROUCT, REQUEST CTLOG REFERENCE N0
Series AN05 to 40 RoHS
ompact Resin Type/Male Thread Series N05 to 40 N 02 05 15 30 40 Thread type M thread Nil R N NPT Thread connection port size pplicable model M5 01 02 03 04 M5 x 0.8 1/8 1/4 3/8 1/2 N05 N N15/ N30 N40 Max.
More informationSeries AN /Series AMC
s/exhaust Cleaner / Noise reduction Nominal filtration rating (eference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting 00 30 db (A) 00 µm 50 µm 5-0-2 Compact type
More informationHow to Order. Body size
Standard Type Series N 00 Over 30 db () noise reduction Low back pressure Compact and easy mounting How to Order N 400 04 Body size 200 300 400 500 600 700 800 900 Thread type Symbol Type Nil R N NPT Symbol
More informationSeries AN /Series AMC
s/exhaust Cleaner / Noise reduction Nominal filtration rating (Reference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting 00 30 db (A) 00 µm 50 µm 5-0- Compact type
More informationAN 00/AN 02/AN 03/25/AN
Silencer AN 00/AN 02/AN 03/25/AN Standard Series AN 00 Over 30dB(A) noise reduction Low back pressure Compact and easy mounting High noise reduction style Series AN 02 Over 35dB(A) noise reduction Case
More informationSteam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam.
Steam Valve Series VN Valve for Steam Valve for Steam Max. 80 y adopting of PT seal, the valve is suited for steam. ody material: ronze, Stainless steel Large valve capacity With indicator (Option) Selectable
More informationVNA VNB SGC SGH VNC VNH VND VCC
Steam Valve VN Series Valve for Steam Valve for Steam Max. 80 y adopting of PT seal, the valve is suited for steam. ody material: ronze, Stainless steel Large valve capacity With indicator (Option) Selectable
More informationTwo Hand Control Valve
Two Hand Control Valve Series n output is available through synchronized, twohanded operation (within 0.5 s)! Conforming to EN574 RoHS (Interchangeable with XT92-67 ) Example of a basic circuit diagram
More informationPower Valve Precision Regulator
Power Valve Precision Regulator VEX Series High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air
More informationHigh Pressure Coolant Valve
High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal
More informationCoolant Valve. VNC Series. Cylinder actuation by pilot air
oolant VN Series ir Operated/xternal Pilot Solenoid [Option] ylinder actuation by pilot air Wide selection of port and variations Threaded type (6 to ) lange type (3 to 80) Low water hammer or details,
More information2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control
Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot
More informationSoft Start-up Valve. AV2000/3000/4000/5000 Series
Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off
More information5 Port Air Operated Valve
Port ir Operated Valve Series VF000/000/000 RoHS 22- Series VF000/000/000 Model Selection by Operating Conditions q ir Operated Valve: Single Unit Series Sonic conductance C[dm /(s bar)] Type of actuation
More information10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry
Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available
More informationExclusively for air pressure system and air-hydro circuit control
Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external
More informationCoolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations
Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large
More informationSpecifications VH600. Ambient temperature and operating fluid temperature. Operating angle Lubrication. Semi-standard
Hand Valve Series VH Specifications Fluid Proof pressure Max. operating VH00/00/00 pressure VH00 Ambient temperature and operating fluid temperature Air.5 MPa.0 MPa MPa -5 to 0 C (No freezing) VH0 VH00
More informationCoolant Valve. Air Operated/External Pilot Solenoid
Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page
More informationSpeed Controller with One-touch Fitting
Speed Controller with One-touch Fitting S Series Push-lock Type Reduces labor time! Easy to use Easy to lock Unlock Push-lock type Lock Improved tube insertion/removal Max. Insertion force: 30% (8 N) reduction
More informationAir Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. Port size: 1/4 to 1 JIS symbol Specifications Description
ir Filter Outdoor Series FW4000/FW8000-W Series Outdoor types now developed into a series. : 1/4 to 1 JIS symbol Specifications FW4000-W FW8000-W Working fluid ompressed air Max. working pressure MPa 1.0
More informationSpeed Controller with Indicator
Speed Controller with Indicator The numerical indication of flow rate knob rotations reduces flow setting time and setting errors! Elbow Universal Brass Electroless nickel plated RoHS Stainless steel 1
More informationHow to Order. Nozzle. Nil Connection size N02 N03 F02 F H06 H08 H10 H07 H09 H11
Blow Gun RoHS How to Order VMG W Blow gun Standard type Series Resin body lever type W BU Piping entry Bottom Top Body color White ark blue Symbol Nil 3 4 3 3 4 3 3 33 34 Male High efficiency Low noise
More informationStandard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve
Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective
More informationAdded 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model
Blow Gun Series 20% reduction in power consumption with the SMC Blow gun + S coupler + Coil tube 10% reduction with the Blow gun () only RoHS With cover Extension nozzle Added mm and 150 mm lengths Pressure
More informationSeries VP3145/3165/3185
Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to
More informationITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa
5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,
More informationMiniature Regulator Series ARJ310
Miniature Regulator Series 30 Compact and lightweight (Main body 65 g) 8.3 Improved flow characteristics 0. 0. 0 00 00 300 400 500 Allows smaller mounting pitch 8.8mm 0-M5 30-0 Inlet pressure: MPa Accommodates
More informationExhaust Cleaner for Clean Room. Body size. Symbol Nil. Size 1/4 standard 3/8 standard 1/2 standard. Element construction. Stage 2 stage.
Exhaust Cleaner for Clean oom Series ohs An exhaust cleaner that can be used inside a clean room How to Order 0 0 Exhaust air cleanliness: Equivalent to ISO Class (Class 0 ed.std.0) (Consult SMC in advance,
More informationAir Suction Filter / In-line Type With One-touch Fittings. Model ZFC ZFC ZFC ZFC ZFC ZFC ZFC ZFC051-03
In-line type air suction filter is used to prevent vacuum equipment trouble from occurring due to dust in the air IN/OUT straight piping Easy installation and removal with one-touch fittings Light and
More information0.35 W (Without light)
Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:
More informationStandard Specifications. Fluid Standard specifications. VH600 Ambient and fluid temperature Operating angle Lubrication. Optional Specifications
Hand Valve Series Standard Specifications Fluid Standard specifications Max.operating,, pressure Ambient and fluid temperature Operating angle Lubrication Air.5MPa.MPa MPa 5 to C (No freezing) 9 Not required/when
More informationStandard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure
Miniature Regulator Series ARJ1020F 2 Construction/Dimensions Lock nut M8 X 0.75 Panel screw Panel mounting hole Precautions Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated /3 Port Solenoid Valve & Check Valve VCH Series VCH4/4: Port VCH40: 3 Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve [Option] VCH40 Series Stable responsiveness Response
More information1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions
Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]
More informationPiping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example
E-P HYREG VY Series This hybrid regulator combines a regulator and a solenoid valve. Stepless control through electric signals Port sizes M5 to inches can be covered by combining an ultra-compact electro-pneumatic
More informationPressure Relief 3 Port Valve With Locking Holes
Doc. No. VH*-OMQ0023-B PRODUCT NAME Pressure Relief 3 Port Valve With Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~02A,B(-B,S)(-K,R,Z) VHS30-(F,N)02~03A,B(-B,S)(-K,R,Z) VHS40-(F,N)02~04A,B(-B,S)(-K,R,Z)
More informationCompact / Lightweight 2 Port Solenoid Valve
ompact / Lightweight 2 Port Solenoid Valve /-XF For ir/water ompact / Lightweight resin body (PPS) Weight: 20 g (-XF) RoHS IP65 mm Power consumption 3 W (Standard) 0.5 W (With power-saving circuit) 48
More informationManifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications
Manifold Regulator Modular Type Series /3000 modular type that can be freely mounted on a manifold station. Optimal for central pressure control. Easily set up using the new handle. lso has a Onetouch
More informationSuction Filter with Case. Specifications. Fluid Operating pressure Operating temperature Cover/Case. Model/Rated Flow Rate. Model
Suction Filter with Case FH99 Series RoHS Compact and lightweight The compact and lightweight design employs an aluminum casted housing. Prevents pump cavitation The inlet size is larger than the outlet
More informationOdor Removal Filter. Model. Note) 1 8, , , , 3 4. Model/Free Standing Type AMF (2B)JIS 10K FF flange
fficiently can remove odor in compressed air with an activated carbon element. The unit is designed for use in the area such as a clean room where odors must be avoided. an remove odor and gas ingredients
More informationSpeed Controller with One-touch Fitting
Speed Controller with One-touch Fitting Series Elbow Type Reduces labor time! Elbow Brass Stainless steel Electroless nickel plated Stainless steel 33 RoHS TMH y Easo t e us Push-lock type Larger handle
More informationManifold Regulator Modular Type. Regulator for manifold. Body size. Number of stations stations. 10 stations. Standard Specifications
Manifold Regulator Modular Type /3000 Series modular type that can be freely mounted on a manifold station. Optimal for central pressure control. Easily set up using the new knob. lso has a One-touch lock
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion
More informationConventional specification. External Pilot air specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized.
Compact, yet keeps large capacity.» Limited space can be utilized. Standard.» SVR 10 series takes over the functions (Valve variations) of discontinued SVA 10 series. Pneumatic Symbols 5(R) 5(R) 5(R) 5(R)
More informationITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*
3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator ITVH Series ARJ RoHS Maximum supply pressure Set pressure range Stability 3.0 MPa 0.2 to 2.0 MPa ARX AMR Stepless control of air
More information1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110
Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902
More informationCAT.ES C. Compact Guide Cylinder. SeriesMGP. ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100. New end lock type introduced to Series MGP
CT.S-7 C Compact Guide Cylinder Series ø, ø, ø, ø2, ø, ø, ø, ø, ø, ø0 New end lock type introduced to Series . Top mount Compact Guide Cylinder Series ø, ø, ø, ø2, ø, ø, ø, ø, ø, ø0 Four mounting types
More informationSpeed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model.
Speed Controller with Uni One-touch Fitting Push-lock type Series Elbow Universal Brass New-stand male threads for piping that reduces the screw-in time by 1/3. Gasket Female thread Rc, G NP, NPF Shape
More informationSeries VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4
Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double
More information4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating,
MNE0 M MN W L/ QV JIS symbol 5 port valve position single solenoid position double solenoid position all ports closed position //R connection position P// connection Common specifications Descriptions
More information3/2-way Solenoid Valve for pneumatics
656 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Type 656 can be combined with... Fast response times Type 506 Type 510/511
More informationCompact direct acting precision regulator
direct acting precision Components preparation and pressure adjustment / unit CONTENTS Product introduction 6 Safety precautions 62 Discrete (RJB500) 624 Block manifold (MNRJB500) 626 Block configurations
More informationProcess Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control
Process Valve: Port Valve For Compressed ir and ir-hydro Circuit Control Series VN Style VN -6 VN -8 8 VN - 3 8 VN - 5 VN -5 VN3-0 3 0 Note) This product cannot be used for water application. JIS Symbol
More informationClean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter
Clean Air Module Series Digital flow switch Regulator ON/OFF valve Restrictor Filter Modularizes clean equipment (Reduced piping man-hours/space-saving). Easily obtains clean air. Built-in one-touch fitting
More informationMini Free Mount Cylinder
Mini Free Mount Cylinder Series ø, ø, ø, ø, ø, ø1, ø Series 1 ction Stroke 1 2 0 0 0 Clean uto switch series None Rod end Male threaded Without thread Solid state switch D-F D-M9 D-M9 W Female threaded
More informationHow to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa
oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time
More informationSpecifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. Semi-standard
Hand Valve Series Specifications 0 0 Fluid Proof pressure Max. operating 00/00/00 pressure 0 mbient temperature and operating fluid temperature Operating angle Lubrication ir.5 MPa.0 MPa MPa 5 to C (o
More informationTransmitters: Relay Valve
Relay Valve VR5/5 Series Appropriate output sequences are affected according to the signal received from the mechanical valve. It is equivalent to the auxiliary relay of an electrical system. Specifications
More informationCompact Direct Operated 2/3 Port Solenoid Valve for Water and Air
Compact Direct Operated / Port Solenoid Valve for Water and Air 0/0/0: Port, 00/00: Port 0/0/0 -port type has been remodeled to new compact and lightweight series. For details about new series, refer to
More informationHow to Order. M5 M5 x 0.8 U10/ UNF
Series -S-FSG Push-lock ype RoHS Speed Controller with Indicator Stainless Steel ype (Elbow/Universal) How to Order 1 ype 2 Elbow 3 Universal Body size -32UNF Port size 5 U/32-32UNF Stainless steel type
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion
More information3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option
3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity
More informationReady for outdoor use too!
Filter/regulator assured for outdoor use New Product Filter/regulator series First in the industry FILTER REGULATOR FOR DOOR USE Ready for outdoor use too! Improved outdoor durability due to the exterior
More information3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics
65 /-way and x /-way Rocker Solenoid Valve for pneumatics Type 65 can be combined with... Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Fast response times Space
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion
More informationMiniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure
Miniature Regulator Series 00F Compact and lightweight ( g) Low cracking pressure 0.0 MPa Standard model equipped with backflow function Standard Specifications Port size Fluid side side (Applicable tubing
More information3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot
3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in
More informationPilot Operated 2 Port Solenoid Valve for Dry Air
Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0
More informationPROCESS & AUTOMATED VALVES
Process & utomated Valves HYDC s line of Process and utomated Valves complements our isolation valve knowhow and ability to supply high quality solutions to your valve requirements. 3-1 HV Series Inline
More informationThe valve body is prepared in two different colors enabling the user to opt for either of the two according to operational environment.
SVB series is best suitable for controlling valve direct mount type vacuum generators (VH, VS type) ilot actuated type conventional solenoid valve. This is a standard model designed to combine excellent
More informationSeries AV2000/3000/4000/5000
Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU
More informationPower Valve: Economy Valve. Standard Specifications. Model VEX55-04
Three functions (pressure regulator, switching valve, and speed controller) are provided by a single valve. The conventional valve combination circuit has been condensed into a single valve. A large capacity
More informationSpecifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication
Hand Valve VH Series VH0 Specifications VH0 Fluid Proof pressure Max. operating VH00/00/00 pressure VH0 Ambient temperature and operating fluid temperature Operating angle Lubrication Air.5 MPa.0 MPa MPa
More informationASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/8 NPT 1/4
Pilot check valve and speed controller are combined. Realizes momentary intermediate stoppage of a cylinder and able to adjust speed control of it. Work piece Example of drop prevention circuit Tubing
More information40-501, , ,
-9 Silencer, plastic. -5, -5 Silencer, sintered bronze. - Flow control silencer. -5 Check valves. -5 Hand sliding valves. -5, -5 Quick couplings. -5 Miniature regulator, screw-in type.6-55 Check valves.7-56,
More informationCircuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control
Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform
More informationSeries VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non
Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non
More informationCompressed Air Cleaning Filter Series
Compressed Air Cleaning Filter For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! AMG C, AFF C, AM C, AMD C AMH C, AME C, AMF C Uses the
More informationTransmitters: Relay Valve VR4151/4152
Relay Valve VR4151/4152 Appropriate output sequences are affected according to the signal received from the mechanical valve. VR4151 VR4152 Precautions Be sure to read before handling. Refer to pages 5-11-2
More information1 1/4 (32A) to 2 (50A) added.
Coolant Valve 0.5 MPa.0 MPa.6 MPa RoHS /4 (3) to (50) added. Flow rate Cv (For 0.5 MPa specification) 3 4 5 0 0 30 Cv (kv) 40 5 million cycles or more Port size 70 6.5 (5.6) 3/8 (0), / (5).8 (0.) 3/4 (0)
More informationCompressed Air Cleaning Filter Series
Compressed Air Cleaning Filter Series Series / For Water, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the F.R.L. combination
More information3 Port Air Operated Valve. SYJA300 Series. How to Order. Nil Without sub-plate. Type of actuation. Normally closed Normally open
3 ort ir Operated Valve SYJ300 Series How to Order SYJ3 M3 Bracket Nil Without bracket F With bracket *The bracket is not mounted. *The bracket cannot be retrofitted later. SYJ3 Type of actuation Normally
More informationSeries VP3145/3165/3185
Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes
More information5 Port, 2 Position Double Solenoid Inline Valve (Series 524)
Port, Position Double Solenoid Inline Valve (Series ) DIN Connector Solenoid Coil Valve Body Piston Seal Profile O Ring Outlet Ports Piston Housing Piston Flat Seal Inlet Flat Seal Spool Manual Override
More informationSeries CYP. Clean rodless cylinder ø15, ø32. How to Order
Series Clean rodless cylinder ø15, ø32 How to Order ir cylinder Clean rodless cylinder ore size (mm) 15 32 15 Cylinder bore size 15 15mm 32 32mm TN TF Port type M5 x 0.8 15 c NPT Standard stroke Standard
More informationDiscrete air operated 2 port valve (compact cylinder valve) NC (normally closed) type
N Series Discrete air operated port valve (compact cylinder valve) N* Series N (normally closed) type, NO (normally open) type, double acting type Port size: Rc/, Rc/ Working fluid: air, water, gas JIS
More informationQ1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.
Multistage Ejector 112/212 Series Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 25% and air consumption reduced 2% with 3 stage diffuser construction (ersus
More informationDoc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number
Doc. no. Coolant valve PRODUCT NAME VNC/VNH Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Precautions
More informationLow Maintenance Filter
Low Maintenance Filter FN/FN Series No more element replacement! Our unique element construction with back-flushing capability The element of the filter is constructed of a series of grooved filter plates
More informationExhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)
5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust
More informationDoc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number
Doc. no. Process valve PRODUCT NAME VNA Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Design
More information5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)
For details about certified products conforming to international standards, visit us at www.smcworld.com. 5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in Model position 3 position
More informationSpecifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication. 3 (Closed center) 3/4, 1 3 (Exhaust center)
Hand Valve Series VH Specifications VH VH Fluid Proof pressure Max. operating VH// pressure VH Ambient temperature and operating fluid temperature Operating angle Lubrication Air.5 MPa. MPa MPa 5 to C
More informationSpecifications. Model/Rated Flow Rate. Accessory/Option. Differential pressure indicator
Oil Filter FH150 Series RoHS ompact and lightweight The compact and lightweight design employs an aluminum alloy cover. Easy maintenance The element slides into place, making it easy to install and remove.
More informationSeries CYP. ø15, ø32 Clean Rodless Cylinder. How to Order
ø15, ø32 Clean odless Cylinder How to Order CYP 15 200 Y59 Clean rodless cylinder Cylinder bore size 15 15 mm 32 32 mm Standard stroke ore size (mm) Standard stroke (mm) 100, 150, 200, 250, 300, 350 15/32
More informationDiscrete direct acting 2 port solenoid valve (general purpose valve) AB31 AB41 Series NC (normally closed) type AB42 Series NO (normally open) type
31414 Series iscrete direct acting port solenoid valve (general purpose valve) 31 41 Series NC (normally closed) type 4 Series NO (normally open) type Port size: Rc1/8 to Rc1/ JIS symbol Common specifications
More informationVacuum / Release Unit
Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow
More informationSeries VKF300 VV061 V100 S070 VQD VKF VK VT VS
Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing
More information