Emprendimiento Fénix Product Catalogue

Size: px
Start display at page:

Download "Emprendimiento Fénix Product Catalogue"

Transcription

1 Product Catalogue Emprendimiento Fénix

2 Emprendimiento Fénix... Perfect Combustion Emprendimiento Fénix, a company devoted to the construction and service of industrial equipment, include in its thermomechanical product line the production, distribution, sales and repairing of METLER and FLAMATIC burners, DTI valves and EFEX heat generators. Also, our company offer various services, including project engineering for furnaces and painting cabins, providing the know how you need and the attention you deserve. Page 1/24

3 A Atmospheric General Characteristics. The A Atmospheric Burners for natural gas and LPG allow you to fulfill your specific heat generation needs, offering capacities between BTU/h and BTU/h, with a wide range of models. Applications. Home boilers. Specially suited for light fuel boilers conversion. Hot air ovens. Photo: tobacco driers. Page 2/24

4 Dimensions by Model. B E G I D A H C F Linear dimensions are in mm and diameters are in inches. Model Capacity Tubes Weight Dimensions (BTU/h) (Kg) A B C D E F G H I A /2 A /2 A , /4 A , Page 3/24

5 CM and Dual CM Pressurized General Characteristics. The CM and Dual CM Pressurized Burners for natural gas, LPG, diesel oil or kerosene allow you to fulfill your specific heat generation needs, offering capacities between BTU/h and BTU/h, with a wide range of models. Applications. Combustion chambers. Specially suited for pressurized ones with high counterpressure levels. Photo: Loos boiler (Peru) Construction. Monoblock compact burner, made of aluminium. Stainless steel combustion head-stock and flame diffusor. Owing to its design, air recirculation takes place on the flame base, thus considerably reducing NOX levels. Combustion head-stocks short or long. High efficiency fan and turbine. Aerodynamic deflectors which do away with useless air recirculation. Electronic switchboard attached to the burner complete with combustion controller, and Gas/Gasoil switch in the dual model. Flange anchors with insulating plate. Programmers with a previous gas removing process, lack-of-air cut-off presostat, high voltage ignition transformers, single-phase motors (triphase on request). Page 4/24

6 Dimensions by Model. A' A B H G C E J F I D1 D2 D4 D3 Linear dimensions and diameters are in mm. Page 5/24

7 Model Capacity (BTU/h) CM a CM a CM a CM a CM a CM a CM a Motor Motor Dimensions Power (HP) Voltage (V) D1 D2 D3 D4 A A B C E F G H I J 0, , , , , / Work Field by Model. mmca 80 CM30 CM40-1 CM CM15 CM CM5 CM BTU/h 1000 Page 6/24

8 Versions. Standard On/Off (L), which start and cut off at a preset temperature level. Two-Stage (D). High and Low Fire (AB), which functions within a temperature scale. Gas Flow Modulating (M), which provides continuous regulation through a digital termostat with a 4 to 20 ma or 0 to 10 V signal and a servomotor valve which keeps the system in continuous balance. All versions equipped with valves and controls following international and local regulations. Page 7/24

9 MDB Pressurized General Characteristics. The MDB Pressurized Burners for natural gas, LPG, gasoil, diesel oil or kerosene allow you to fulfill your specific heat generation needs, offering capacities between BTU/h and BTU/h. Applications. Great requirements applications. Photo: Duoblock burner in sand drier. Page 8/24

10 OMC/PFG Pressurized General Characteristics. The OMC/PFG Pressurized Burners for gasoil, diesel oil and kerosene allow you to fulfill your specific heat generation needs, offering capacities between BTU/h and BTU/h, with a wide range of models. Applications. Standard and pressurized boilers. Furnaces. Hot air generators. Driers. Thermal procceses in general. Photo: Eratic Gonella oil boiler. Dimensions by Model. Model OMC15 OMC25 OMC30 OMC40 PFG5 PFG6 PFG7 PFG8 Capacity (BTU/h) a a a a a a a a Motor Ignitions Weight (Kg) Dimensions Power (HP) Phases D1 D2 D3 D4 A B C E F G 0, , , , , Page 9/24

11 A B D1 E F H I D3 D D4 D2 D4 D2 Linear dimensions and diameters are in mm. Construction. Monoblock compact burner made of aluminium. Stainless steel combustion head-stock and flame diffusor. Page 10/24

12 PF and Dual PF Pressurized General Characteristics. The PF and Dual PF Pressurized Burners for natural gas, LPG, diesel oil or kerosene allow you to fulfill your specific heat generation needs, offering capacities between BTU/h and BTU/h, with a wide range of models. Applications. Heat exchangers. Steam or hot water boilers. Air-heating systems. Furnaces. Driers Termal processes in general. Specially suited for combustion fireplaces with high counterpressure levels. Photo: Gonella boiler. Construction. Monoblock compact burner, made of aluminium. Stainless steel combustion head-stock and flame diffusor. Owing to its design, air recirculation takes place on the flame base, thus considerably reducing NOX levels. Three types of head-stock (straight, conical and ciclonical), which guarantee perfect combustion in all cases. Multiple-blade turbine with a curved wicket gate. Directional burner (to the left and the right), to simplify the tasks at the flame end, diffusor and electrodes. Page 11/24

13 Dimensions by Model. B A A' C E D1 F H G 45 D3 D3 60 D4 D2 D4 D2 Linear dimensions and diameters are in mm. Page 12/24

14 Model Capacity Motor Power (HP) Dimensions (BTU/h) Gas Dual D1 D2 D3 D4 A A B C E F G H PF , a PF a PF a PF7/ a PF a 7,5 7, PF8/ a 12,5 12, PF a Work Field by Model. 180 mmca PF PF6 PF7/8 PF8 PF7 PF8/9 100 PF BTU/h 1000 Page 13/24

15 Versions. Standard On/Off (L), which start and cut off at a preset temperature level. High and Low Fire (AB), which functions within a temperature scale. Gas Flow Modulating (M), which provides continuous regulation through a digital termostat with a 4 to 20 ma or 0 to 10 V signal and a servomotor valve which keeps the system in continuous balance. All versions equipped with valves and controls following international and local regulations. Page 14/24

16 MV and MVA Air Duct General Characteristics. The MV and MVA Air Duct Burners for natural gas and LPG allow you to fulfill your specific heat generation needs, offering capacities between BTU/h and BTU/h, with a wide range of models. The MV and MVA Air Duct Burners have been specially designed to work as direct hot air generators in air ducts. Applications. Air Heating in all kinds of industrial processes. Cereal driers. Spraying systems. Paint ovens. Cloth polimerization processes. Driers for fruits, vegetables, mineral and chemical products. Airing chambers. Photo: PMMA forge accelerator. Construction. Models with fan (MVA) and without it (MV) to be used within air flows with speeds between 15 and 25 m/seg. Alternatively, they can be made to suit specific requirements. Progressive distribution of gas outlets, which made possible the modification of the gas flow without the change of the mixed air volume, thus achieving a gas modulation between 5% and 100 %. IP55 type control panel, fully suitable for open air use, with on/off lights, and provided as a part of the burner or connected to it and to be located at a distance. Equipped with fastening supports which can suit the customers' specific requirements. Programmers with a previous gas removing process. Automatic ignition. Page 15/24

17 Detection by ionization rod or ultraviolet sensor. Blockage in case of lack of air for the fan. Blockage in case of lack of flame. Safety selenoide valves which cut off the gas flow in less than a minute if the system is faulty. Alarm. Pressure gauge. High and low pressure gas cutting gauge/valve/switch. Versions. Standard On/Off (L), which start and cut off at a preset temperature level. High and Low Fire (AB), which functions within a temperature scale. Gas Flow Modulating (M), which provides continuous regulation through a digital termostat with a 4 to 20 ma or 0 to 10 V signal and a servomotor valve which keeps the system in continuous balance. All versions equipped with valves and controls following international and local regulations. Dimensions by Model. Model MV100 MVA100 MV300 MVA300 MV500 MVA500 MV600 MVA600 MV700 MVA700 MV1000 MVA1000 MV1200 MVA1200 Capacity Modules Fan Motor Power Dimensions (BTU/h) (HP) A B C D Up to CM15 1/ Up to CM30 3/ Up to PF Up to PF Up to Up to Up to PF6 5, Page 16/24

18 D 150 B A C 360 Linear dimensions and diameters are in mm. Page 17/24

19 MVS and MVAS Air Duct General Characteristics. The MVS and MVAS Air Duct Burners for natural gas and LPG allow you to fulfill your specific heat generation needs, offering capacities between BTU/h and BTU/h, with a wide range of models. Applications. Cereal driers. Photo: cereal drier. Dimensions by Model. Model MVS600 MVAS600 MVS1000 MVAS1000 MVS1500 MVAS1500 MVS2000 MVAS2000 MVS2500 MVAS2500 MVS3000 MVAS3000 Capacity (BTU/h) Up to Up to Up to Up to Up to Up to Modules Fans Motor Power Dimensions (HP) A B C , , , Page 18/24

20 200 B 100 A C Linear dimensiones and diameters are in mm. Page 19/24

21 Special Projects Applications. Upper Photo: hot air generator, for big volumes with high air pressure. Lower Photo: environmental decontaminator, for continaminating gas burning in fireplaces. Page 20/24

22 Valves and Spare Parts General Characteristics. The F Solenoid Valves are two-ways direct action valves, with quick opening and closing, which allow the possibility of an easy installation of various accessories that extend their basic control and adjustment functions. These valves have the Class A official recognition. Dimensions by Model. Model Connection Thread ( ) Working Pressure (mbar) Opening and Closing Time (seg) Working Temperature ( C) Gas Passage Dimensions Hole (mm) A B C D E F40 1 ½ BSP 350 <1-15 ~ F50 2 BSP 250 <1-15 ~ Page 21/24

23 B C A D E Linear dimensions are in mm. Page 22/24

24 Slow Opening Accessory. Quick opening, adjustable up to 50% of total flow, with speed register. Adjustable height between 0% and 100% of total flow. Instantaneous return of the control axis, allowing the valve to work again immediatily. Other Accessories. Closed valve sense microswitches. Pressure gauges. Spare Parts. Upper photo: servomotor for air and gas register. Page 23/24

25 Index Emprendimiento Fénix... Perfect Combustion A Atmospherics General Characteristics Applications Dimensions by Model CM and Dual CM Pressurized General Characteristics Applications Construction Dimensions by Model Work Field by Model Versions MDB Pressurized General Characteristics Applications OMC/PFG Pressurized General Characteristics Applications Dimensions by Model Construction PF and Dual PF Pressurized General Characteristics Applications Construction Dimensions by Model Work Field by Model Versions MV and MVA Air Duct General Characteristics Applications Construction Versions Dimensions by Model MVS and MVAS Air Duct General Characteristics Applications Dimensions by Model Special Projects General Characteristics Applications Valves and Spare Parts General Characteristics Dimensions by Model Slow Opening Accessory Other Accessories Spare Parts Page 24/24

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw LOW NOx T The RL/M BLU burners series covers a firing range from 360 to 1023 kw, and it has been designed for use in hot or superheated water boilers, hot air or steam generators and diathermic oil boilers.

More information

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw. The Riello Gulliver BSD series of two stage gas burners, is a complete range of Low NOx emission products, developed to respond to any request for home heating, conforming to the most severe standards

More information

ONE STAGE GAS BURNERS RDBS SERIES

ONE STAGE GAS BURNERS RDBS SERIES ONE STAGE GAS BURNERS RDBS SERIES 16 47 kw RDBS.1 16 47 kw The Riello RDBS is a new series of one stage gas burners with integrated gas train, characterised by its small dimensions in spite of its high

More information

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO GS/M SERIES GS /M / 5 3/8 19 The Riello GS/M series of two stage progressive or modulating gas burners, is a complete range of products developed

More information

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw. The Riello Gulliver BS series of one stage gas burners, is a complete range of Low NOx emission products, developed to respond to any request for home heating, conforming to the most severe standards regarding

More information

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw The Riello 40 F series of one stage light oil burners, is a complete range of products developed to respond to any request for light industrial applications. The Riello 40 F series is available in three

More information

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES The RS burners series covers a firing range from 44 to 2290 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

RS/M SERIES. Modulating Gas Burners FIRING RATES

RS/M SERIES. Modulating Gas Burners FIRING RATES The RS/M burners series covers a firing range from 45 to 2650 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL The Riello RDB series of one stage light oil and kerosene burners is available in eleven basic models, with an output ranging from 16,8 to 120 kw, in three different structures. The models are available

More information

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS The Riello 40 FS series of one stage gas burners, is a complete range of products developed to respond to any request for light industrial application. The Riello 40 FS series is available in five different

More information

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES The RS/E-EV MZ burners series covers a firing range from 44 to 2650 kw, and it is based on a new Digital Burner Management System, Riello REC27, which is able to manage the air-fuel ratio by independent

More information

PRESS P/N - P/N ECO SERIES

PRESS P/N - P/N ECO SERIES The PRESS P/N series of burners covers a firing range from 800 to 5130 kw. They have been designed in three versions for use in commercial and industrial installation, to burn different oil viscosity from

More information

Doing more for clean environment and energy saving

Doing more for clean environment and energy saving Doing more for clean environment and energy saving Rütli Burners Switzerland AG is a worldwide leading industrial burner solution supplier. Our head quarter is located in Schaffhausen, Switzerland one

More information

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw The Riello 40 GS series of one stage gas burners, is a complete range of products developed to respond to any request for home heating. The Riello 40 GS series is available in four different models, with

More information

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS The RS/1 series of burners covers a firing range from 70 to 550 kw, and they have been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers.

More information

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES The PRESS G series of burners covers a firing range from 107 to 1660 kw and they have been designed for use in civil installations of average dimensions, like building areas and large apartment groups

More information

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw ONE STAGE GAS BURNER GULLIVER RSF SERIES 160 330 kw The Riello Gulliver, is a new model of the series of one stage gas burners, developed to respond to any request for light industrial processes like bakery

More information

RES G MRBLU SERIES. Low NOx One Stage Light Oil Burners FIRING RATES. LOW NOx LIGHT OIL

RES G MRBLU SERIES. Low NOx One Stage Light Oil Burners FIRING RATES. LOW NOx LIGHT OIL Low NOx One Stage Light Oil Burners RES G MRBLU SERIES LOW NOx LIGHT OIL RES (Riello Environment Solution) is the new Low NOx light oil burners series with extremely low emissions to meet the increasingly

More information

KOLHAPUR FOUNDRY & ENGINEERING CLUSTER

KOLHAPUR FOUNDRY & ENGINEERING CLUSTER KOLHAPUR FOUNDRY & ENGINEERING CLUSTER With reference to 24 th April 2016 Tender Notice published in Maharashtra Times & Times of India for GSR, Water Tank, Screw Compressor, LPG system, Lab testing equipments

More information

Gas burner Dual fuel burner. Gas burner. Series RG GG MG. Dual fuel burner. Series MK

Gas burner Dual fuel burner. Gas burner. Series RG GG MG. Dual fuel burner. Series MK Gas burner Dual fuel burner Gas burner Series RG GG MG Dual fuel burner Series MK Series RG Fully automatic gas burner, tested and approved in accordance with DIN EN 676 suitable for the combustion of

More information

CODE MODEL TYPE PRESS GW 605 T80

CODE MODEL TYPE PRESS GW 605 T80 Installation, use and maintenance instructions Pressure jet burner CODE MODEL TYPE 3473784 PRESS GW 605 T80 291 (2) - 08/2012 Thermal power 107 / 178-350 kw - 92.000 / 153.000-301.000 kcal/h Output 9/15-30

More information

ONE STAGE GAS BURNERS RS/1 SERIES RS 28/ kw RS 34/1 MZ kw RS 38/ kw RS 44/1 MZ kw

ONE STAGE GAS BURNERS RS/1 SERIES RS 28/ kw RS 34/1 MZ kw RS 38/ kw RS 44/1 MZ kw ONE STAGE GAS BURNERS RS/1 SERIES RS 28/1 163 349 kw RS 34/1 MZ 7 39 kw RS 38/1 232 465 kw RS 44/1 MZ 55 kw The RS/1 series of burners covers a firing range from 7 to 55 kw, and they have been designed

More information

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES 1/19 5 kw 35/4 91 kw 5/75 19 kw 11/14 4 kw The Riello Gulliver BSD series of two stage gas burners, is a complete range of Low NOx emission products, developed

More information

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS Operations and Maintenance Manual for INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS Models MD-25-OG MD-7500-OG December 2012 Copyright 2012 Periflame, Design Guide 113 Industrial Dual-Fuel Burners, 12/01/2012

More information

Retrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung. Dr.-Ing. Marco Derksen

Retrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung. Dr.-Ing. Marco Derksen Retrofit von Industriekesseln zur Brennstoffänderung und NOx- Reduzierung Dr.-Ing. Marco Derksen Contents NOx formation In-furnace NOx reducing measures Application of premixed combustion Experiences in

More information

RS Series Two Stage Progressive Gas Burners

RS Series Two Stage Progressive Gas Burners Technical Data Leaflet Gas TS0046UK06 RS Series Two Stage Progressive Gas s RS 34 MZ 70/130 390 kw RS 44 MZ 101/203 550 kw RS 50 116/290 580 kw RS 64 MZ 150/400 850 kw RS 70 192/465 814 kw RS 100 232/698

More information

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw TWO STAGE GAS BURNER GULLIVER RSD SERIES 160/208 345 kw The Riello Gulliver is a new model of the series of two stage gas burners, characterized for its small dimensions in spite of its high combustion

More information

TWO STAGE LIGHT OIL BURNERS PRESS G SERIES

TWO STAGE LIGHT OIL BURNERS PRESS G SERIES TWO STAGE LIGHT OIL BURNERS PRESS G SERIES 7/178 356 kw PRESS 1G 13/19 534 kw PRESS 2G 214/356 712 kw PRESS 3G 273/534 1168 kw PRESS 4G 415/83 166 kw The PRESS G series of burners covers a firing range

More information

available in battery up to 4 units for a total of 560 kw

available in battery up to 4 units for a total of 560 kw MODULATING CONDENSING BOILER with double premix low NOx burner and double heat exchanger EXPANDABLE IN BATTERY for indoor and outdoor installations (IPX5D) OUTPUT RANGE from 10 to 560 kw (in battery) WORKING

More information

S1 SERIES TECHNICAL DATA INFORMATION PACKET

S1 SERIES TECHNICAL DATA INFORMATION PACKET S1 SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions S1G, S1L, S1LG Technical Data Sheet...3 Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions S1E, S1EG Technical

More information

DB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00

DB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00 Technical Data Leaflet Industrial TS0086UK00 DB Series Industrial Dual Block Oil, Gas and Dual Fuel Burners DB 4 1000/2500 5000 kw DB 6 1400/4000 7800 kw DB 9 1500/5000 9500 kw DB 12 1700/7000 12500 kw

More information

TWO STAGE PROGRESSIVE GAS BURNERS

TWO STAGE PROGRESSIVE GAS BURNERS TWO STAGE PROGRESSIVE GAS BURNERS RS SERIES RS 28 81/163 325 RS 34 MZ 7/125 39 RS 38 15/232 44 RS 44 MZ 1/2 55 RS 5 116/29 58 RS 64 MZ 15/4 85 RS 7 192/465 814 RS 1 232/698 1163 RS 13 372/93 1512 RS 19

More information

AMR. GB-Ganz Tüzeléstechnikai Kft. MODULATING DUOBLOCK BURNER FAMILY

AMR. GB-Ganz Tüzeléstechnikai Kft. MODULATING DUOBLOCK BURNER FAMILY AR ODULATING DUOBLOCK BURNER FAILY Flexible turndown range High combustion efficiency Reliable construction Easy and simple to maintenance Environmentally friendly * Nyilvántartási szám: HU-SZT - 503 /

More information

Date: Project #: Engineer: Prepared By: Bid Date:

Date: Project #: Engineer: Prepared By: Bid Date: NEOTHERM Hydronic Boiler NTH Hydronic Boiler Indoor Sizes 285-850 Date: Submittal Data Project #: Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment High condensing

More information

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53 Installation, use and maintenance instructions Kerosene burners One stage operation CODE MODEL TYPE 3749053 G3BF 490T53 374957 G5BF 49T57 3748953 G5BF 489T53 9036 (6) TECHNICAL FEATURES TYPE - Boiler

More information

Energysaver 559FT. Rinnai New Zealand Limited Page 1 of 6 Rinnai Energysaver 559FT Spare Parts: 01-11

Energysaver 559FT. Rinnai New Zealand Limited Page 1 of 6 Rinnai Energysaver 559FT Spare Parts: 01-11 039 017 028 012 019 037 020 018 038 026 701 013 038 027 804 012 Top panel 1 5485 013 Control panel assembly 1 5486 016 Side panel RH 1 5488 017 Side panel LH 1 5489 018 Air filter assembly 1 3026 019 Front

More information

Oil, gas and dual fuel burners. Burner series

Oil, gas and dual fuel burners. Burner series Oil, gas and dual fuel burners Burner series 350...450 Group 4B Capacity 700-5500 kw 1 2 Table of contents General 5 Light fuel oil burners 6 Dimensions and PI diagram 6 Technical data 7 Capacity/back

More information

SPARE PARTS LIST - July

SPARE PARTS LIST - July Versions for CANADA SPARE PARTS LIST - July 2005 - HOW TO READ THE SPARE PARTS CATALOGUE In the spare part catalogue, after the exploded diagrams, there are the components lists of the boilers; this is

More information

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies:

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies: Airejet Low NOx Coal Burner Unique low NO X coal burner with center air jet for use with overfire air (OFA) systems. Sleeve Damper Actuator Core Air Inlet Duct and Damper Pitot Grid Outer Spin Vanes Inner

More information

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 GB

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 GB Weishaupt Monarch oil burners Sizes 5 to 11 1/ GB 1 Description, Types of regulation, Model overview Weishaupt Monarch oil burners are of the fully automatic pressure atomising type. Their design has been

More information

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM DIESEL SPACE HEATER - SERVICE MANUAL INDEX 1. CONTROLS AND COMPONENTS 2. FLAME CONTROL CYCLES 3. MAINTENANCE SCHEDULE 4. REPAIR PROCEDURES 1. FAN MOTOR ASSEMBLY 2. FUEL FILTER ASSEMBLY 3. FUEL PUMP ASSEMBLY

More information

Controls and Accessories Part Number Controls and Accessories Part Number

Controls and Accessories Part Number Controls and Accessories Part Number Linea 24 Mark 1 Serial Number Up to 161380001 Controls and Accessories Part Number Controls and Accessories Part Number CLOCK - MECHANICAL 201 CLOCK - DIGITAL 202 CONVERSION KIT LPG - NG 01005225 CONVERSION

More information

PRODUCT RANGE A COMPLETE RANGE OF BURNERS FROM 17 TO kw

PRODUCT RANGE A COMPLETE RANGE OF BURNERS FROM 17 TO kw www.ecoflam-burners.com PRODUCT RANGE 2015 A COMPLETE RANGE OF BURNERS FROM 17 TO 34000 kw CUTTING-EDGE BURNERS FOR HEATING AND INDUSTRIAL APPLICATIONS Our proposal Ecoflam offers a full range of blown

More information

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER TECHNICAL MANUAL GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER GREENOx/GREENOx.e/K WITH THREE GAS PASSES DUAL GRX/DUAL GRX.e THREE GAS

More information

TEMINOX GLS. Mono-/Duoblock Pressure Jet. Advantages. Capacity range Fuels

TEMINOX GLS. Mono-/Duoblock Pressure Jet. Advantages. Capacity range Fuels Mono-/Duoblock Pressure Jet TEMINOX GLS Advantages Highest quality standard by latest state of production engineering, application of ISO 9001 quality management system European type approval (EN 267 /

More information

Kerosene - oil burner

Kerosene - oil burner Installation, use and maintenance instructions Kerosene - oil burner Two stage operation CODE MODEL TYPE 3746686 G0D 76T8 90 (0) TECHNICAL FEATURES Thermal power output 44 / 54 0 kw 3.7 / 4.5 0 kg/h Fuel

More information

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve NEOTHERM Hydronic Boiler NTH Hydronic Boiler Date: Indoor Sizes 285-850 Submittal Data Project #: Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment Large LCD display

More information

Weishaupt Monarch oil burners Sizes 1 and 3 1/2002 GB

Weishaupt Monarch oil burners Sizes 1 and 3 1/2002 GB Weishaupt Monarch oil burners Sizes 1 and 3 1/ GB Description Weishaupt Monarch oil burners are of the fully automatic pressure atomising type. Their design has been carefully considered down to the smallest

More information

SMI SERIES MOTORS WITH INTEGRATED INVERTER

SMI SERIES MOTORS WITH INTEGRATED INVERTER SERIES MOTORS WITH INTEGRATED INVERTER Series series is made up of three-phase asynchronous electric motors with integrated frequency inverter.power range is between 0,37 kw and 4 kw, while motor axis

More information

» Features. » Applications. Product Range Flow Sensors. Thermal Anemometer No moving parts Immersion probe Transformer integrated

» Features. » Applications. Product Range Flow Sensors. Thermal Anemometer No moving parts Immersion probe Transformer integrated » Features Thermal Anemometer No moving parts Immersion probe Transformer integrated» Applications Cleanroom Technology Process Technology Compressed-air metering Kilns and Ovens SCHMIDT Flow Sensor SS

More information

Retrofitting of Mitsubishi Low NOx System

Retrofitting of Mitsubishi Low NOx System 111 Retrofitting of Mitsubishi Low NOx System Susumu Sato *1 Yoshinori Kobayashi *1 Takao Hashimoto *2 Masahiko Hokano *2 Toshimitsu Ichinose *3 (MHI) has long been engaged in low NOx combustion R & D

More information

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA 1 Description, Types of regulation, Model overview Weishaupt Monarch oil burners are of the fully automatic pressure atomizing type. Their design has

More information

Section 3 Technical Information

Section 3 Technical Information Section 3 Technical Information In this Module: Engine identification Modes of operation Battery charging and heat manage operation Service and repair procedures Maintenance requirements Engine Identification

More information

M K. MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency

M K. MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency M K MK is a pressurized steel boiler for heating system with hot water production up 90 C. High efficiency Gas/ gas oil working Output from 44 to 291,7 (from 37.840 to 250.862 of water efficiency). Pipe

More information

Oil, Gas and Dual Fuel Monoblock Burners

Oil, Gas and Dual Fuel Monoblock Burners Capacity Oil, Gas and Dual Fuel Monoblock Burners 1-133 kw 1 Low Emission Combustion Technology Table of contents 2 Oilon Burners 8 Choosing the burner 9 NOx emissions 1 FGR - Flue Gas Recirculation 11

More information

Oil - kerosene burner

Oil - kerosene burner Installation, use and maintenance instructions Oil - kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 9038 () TECHNICAL FEATURES Thermal power output 8 0 kw.3 5 kg/h Fuel Gas oil 35s,

More information

3 Edition Product brochure GB AGA

3 Edition Product brochure GB AGA TC AGA Tightness controls Adjustable test period which can be adapted to different systems Adjustable test instant allows quick system start Maximum safety thanks to self-monitoring electronics Product

More information

1470 SERIES HOT AIR GAS BURNER

1470 SERIES HOT AIR GAS BURNER 1 SERIES HOT AIR GAS BURNER CAPABILITIES High or low temperature furnace High excess air 800% or more Ratio or tempered flame operation Nominal capacity range 0,000 to 3.5 MM Btu/hour Suitable for light

More information

Installation- and maintenance instruction B80-2/3

Installation- and maintenance instruction B80-2/3 Installation- and maintenance instruction B80-2/3 1 171 625 22 05-01 178 002 64 DESCRIPTION COMPONENTS 1. Flame cone 2. Shrouded disc 3. Nozzle 4. Nozzle assembly 5. Ignition electrodes 6. Ignition cable

More information

MAINTENANCE CHECKLIST & SCHEDULE FOR THE IDH RANGE

MAINTENANCE CHECKLIST & SCHEDULE FOR THE IDH RANGE MAINTENANCE CHECKLIST & SCHEDULE FOR THE IDH RANGE INDUSTRIAL DIESEL HEATERS Details about recommended maintenance checks, components brief and how to check and replace parts as part of the maintenance

More information

Combination controls CG 10

Combination controls CG 10 Combination controls CG 0... Edition 03. GB Combination controls CG 0 Complete with strainer, two solenoid valves and servo-governor for maximum regulation precision. Special low-noise valves. Optional

More information

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT The LNV/Series gas, oil, and combination gas/oil burner is a forced draft packaged burner system. A balanced blower wheel mounted in a fabricated housing provides combustion air for various furnace pressures

More information

TECHNICAL DATA LEAFLET GAS. RS/1 Series. One Stage Gas Burners. RS 34/1 MZ kw RS 44/1 MZ kw.

TECHNICAL DATA LEAFLET GAS. RS/1 Series. One Stage Gas Burners. RS 34/1 MZ kw RS 44/1 MZ kw. TECHNICAL DATA LEAFLET GAS RS/1 Series One Stage Gas Burners RS 34/1 MZ 7 39 kw RS 44/1 MZ 1 kw www.riello.com One Stage Gas Burners RS/1 Series The RS/1 series of burners covers a firing range from 7

More information

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE SIT Group 822 NOVAMIX MULTIFUNCTIONAL GAS CONTROL GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE SERVO-CONTROLLED PRESSURE REGULATOR PIN

More information

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable product Information on oil, gas and dual fuel burners Minimale Industrial Emissionswerte burners mit Gas Industrial burners 1, 11,7 kw flexible and reliable Weishaupt Industrial Burners: Flexible and reliable

More information

Linea 28 Mark 1. Serial Number up to VOKERA SPARE PARTS BREAKDOWN

Linea 28 Mark 1. Serial Number up to VOKERA SPARE PARTS BREAKDOWN Linea 28 Mark 1 Serial Number up to 164370001 Outer Casing 1 RIVET 5093 5 LABEL 1781 2 LOCATING CLIP R/H 1881 6 CASE 1922 3 CLIP 5230 7 LOCATING CLIP L/H 1882 4 SELF ADHESIVE ALUM SHEET 5333 1 Main Frame

More information

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents D Series Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 D Series Uncontrolled Emissions DM,

More information

VAL6 KBE5S. Service Manual

VAL6 KBE5S. Service Manual VAL6 KBE5S Service Manual 1 2 Specifications Type VAL6 KBE5S Heat Output 111,000BTU/h Fuel Kerosene, Diesel Tank Capacity 9 gallons Fuel Consumption 0.85gallon/h Power Source 120V, 60Hz single phase Power

More information

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 Uncontrolled Emissions DM, DMG Technical Data

More information

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01 Gasloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating G-M(P) 057 D01 Two stage operating mode G-(LEP)Z 057 D01 Technical Description Multifunctional gas

More information

product WM 20 for oil, gas and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on oil, gas and dual-fuel burners

product WM 20 for oil, gas and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on oil, gas and dual-fuel burners product Information on oil, gas and dual-fuel burners WM 20 for oil, gas and dual-fuel WM 20 monarch burners (150 2600 kw) compact and powerful Progress and tradition: The latest monarch burner The monarch

More information

Mobile Diesel Heaters TOR / MIR Technical Training Course

Mobile Diesel Heaters TOR / MIR Technical Training Course Mobile Diesel Heaters TOR / MIR Technical Training Course 1 Rev. No. 0 March 3 rd, 2010 MIR Indirect-fired Diesel Heaters MIR 37 WE MIRAGE 37 H MIR 55 WE MIRAGE 55 H (EURO MODELS) MIR 85 WE MIRAGE 85 H

More information

G23 Bulletin # September 1998 Supersedes June 1995

G23 Bulletin # September 1998 Supersedes June 1995 ENGINEERING DATA ELITE 80Z UP-FLOW GAS FURNACES *80.0% to 80.8% A.F.U.E. 50,000 to 150,000 Btuh (14.7 to 44.0 kw) Gas Heating Input 1 thru 6 Tons (3.5 thru 21.1 kw) Nominal Add-On Cooling *Isolated Combustion

More information

North American 4485 Tempest SE

North American 4485 Tempest SE Combustion North American 4485 Tempest SE Medium/High Velocity Gas Burner Low NOx gas burner, durable construction and flexible desgin to fit a variety of applications. NPT or BSP air/gas inlets, adjustable

More information

Oil, Gas and Dual Fuel Burners

Oil, Gas and Dual Fuel Burners Oil, Gas and Dual Fuel Burners Burner series 130...150 50, 0 Group 3 Capacity 390-3,500 Table of contents General 1 How to choose a burner Light oil burners Technical data and dimensions 3- PI-diagrams

More information

1070 SERIES ULTRA LOW NO X

1070 SERIES ULTRA LOW NO X CAPABILITIES High release rates with moderate air Good turndown with flame characteristics and direction maintained Stable flames can be from highly oxidizing for tempered flame operation to highly reducing

More information

Installation- and maintenance instruction BENTOFLEX ST 108 PL

Installation- and maintenance instruction BENTOFLEX ST 108 PL Installation- and maintenance instruction BENTOFLEX ST 108 PL 1 171 625 30 03-01 178 001 13 DESCRIPTION COMPONENTS 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly

More information

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS SELECTION GUIDE The following data can be used to fill in the information appropriate for the burner size required: FD68 C A 150 L M BD FORCED DRAFT MODEL 68 FUEL A-OIL ONLY G-GAS ONLY C-GAS/OIL TYPE OF

More information

Light oil - kerosene burner

Light oil - kerosene burner Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 3747455 G0KI 474T5 90403 (4) - 0/008 TECHNICAL DATA Thermal power output 95 3 kw 8 8 kg/h

More information

LP BURNER SERIES.

LP BURNER SERIES. LP BURNER SERIES The Limpsfield LP burner series is characterised by a monoblock structure meaning all necessary components can be combined into a single unit, making installation and set-up easier and

More information

Mobile Diesel Heaters GRY-D / GRY-I Service Training Course

Mobile Diesel Heaters GRY-D / GRY-I Service Training Course Mobile Diesel Heaters GRY-D / GRY-I Service Training Course 1 Rev. No. 3 January 24, 2011 GRY-I Indirect-fired Diesel Heaters GRY-I 15 WU GRYP 50 AP GRY-I 25 WU GRYP 90 AP GRY-I 40 WU GRYP 135 AP 2 GRY-D

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS 27 BFFI PLUS Edition 4 Current from Serial No: 2320317800001 to: ------------------ Add to Edition 3 1 71 70 9 8 7 5 9 3 4 3 5 7 5 1 2 1 8 9 120 0

More information

Installation- and maintenance instruction BENTOFLEX ST120KAV

Installation- and maintenance instruction BENTOFLEX ST120KAV Installation- and maintenance instruction BENTOFLEX ST120KAV 1 171 625 61 05-01 178 001 16 DESCRIPTION COMPONENTS 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly

More information

Ignition devices. Lighting up Innovation

Ignition devices. Lighting up Innovation Ignition devices Lighting up Innovation Proven leader in the industrial ignition industry, Tesi manufactures a unique range of high energy, high voltage and portable ignition systems assuring ignition

More information

2.0 Burner Operating Parameters and Requirements

2.0 Burner Operating Parameters and Requirements ECLIPSE INFORMATION GUIDE Silicon Carbide Radiant Auto-Recupes Info 322 2/99 WARNING Handle silicon carbide tubes carefully. Do not drop them or hammer on them. Although they feature excellent mechanical

More information

Spare parts list CDI RSF 22/04/

Spare parts list CDI RSF 22/04/ Spare parts list 6720620013 26CI RSF 22/04/2009 6720620013 1 22/04/2009 6720620013 2 22/04/2009 6720620013 3 Spare parts list 1 Pump / Hydraulic assy 22/04/2009 6720620013 4 Pos description S-Nr ordering

More information

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET Technical Data Uncontrolled Emissions Configuration (EG, EL, ELG) 8.4-42.0 MM BTU/H NG; 60-300 GPH #2 OIL UL listed with choice of NFPA, CSD-1, GAP, and

More information

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence The Universal TM gas LowNOx series water heaters contain an electronic spark ignition system. The heater is connected to a 120VAC power source required by the transformer. The transformer steps down the

More information

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-547-1000 parts_team@lochinvar.com www.lochinvar.com Knight Fire Tube Boilers KH 55 thru 285 44 3 4 43 2 47 46

More information

Weishaupt oil burners Sizes 30 to 70 1/2003 CA

Weishaupt oil burners Sizes 30 to 70 1/2003 CA Weishaupt oil burners Sizes 0 to 70 1/00 CA Description Weishaupt burners of sizes 0 to 70 were specially designed and developed for industrial applications. The Monoblock-Burners are characterized with

More information

R&D on Oil-Burning, Environment - Friendly, High-Efficiency Boiler

R&D on Oil-Burning, Environment - Friendly, High-Efficiency Boiler 2001.M4.3.1 R&D on Oil-Burning, Environment - Friendly, High-Efficiency Boiler (Environment-Friendly, High-Efficiency Boiler Group) Takashi Murakawa, Hiroshi Kato, Hiroshi Matsumoto, Kentaro Sato, Yasuhiro

More information

VALUPAK. Packaged gas burners

VALUPAK. Packaged gas burners VALUPAK Packaged gas burners Low Temperature Burners - VALUPAK 1-1.5-1 High turndown. Available in 6 sizes. Capacities: 2 kw -1124 kw (HHV). Stable and clean combustion. Suitable for UV scanner and flame

More information

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust. VARIO VARIO Separation of fine dust particles The VARIO series is particularly suitable for separation of fine dust. The VARIO units are of modular construction in order to meet different requirements,

More information

MULTIFIRE. High temperature dual fuel burner

MULTIFIRE. High temperature dual fuel burner MULTIFIRE High temperature dual fuel burner High temperature burners - MULTIFIRE 3-11.3-1 Operates on-ratio or with excess air to meet the specific demands of your combustion process needs Burns most clean,

More information

REPLACEMENT PARTS LIST. M1 Series

REPLACEMENT PARTS LIST. M1 Series REPLACEMENT PARTS LIST M Series Model MG(*) Item Description MGH MG(B,C,D) 056 070 077 090 056 070 077 090 Louvered Door (White) 9007 9007 9007 9007 9007 9007 9007 9007 Coil Door (White) 9009 9009 9009

More information

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM

EDM Series EDM-80N EDM-80L EDM-100 EDM-200 AXIAL BATHROOM FANS. Bathroom extract fans EDM AXIAL BATHROOM FANS EDM Series EDM-80N EDM-80L EDM-100 EDM-200 0 015982 603071 Installation examples Ceiling or wall mounting Extract ventilation through short duc extract ventilation Extract ventilation

More information

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105 TECHNICAL CATALOGUE WPHA Cooling only WPHBA Heat pump Models 091, 121, 141, 171, 201, 251, 351, 401, 501, 701, 751, 1001, 1201 Cooling capacities from 2,4 kw to 41 kw Heating capacities from 2,8 kw to

More information

Installation- and maintenance instruction ST120 S75/21

Installation- and maintenance instruction ST120 S75/21 Installation- and maintenance instruction ST120 S75/21 1 171 615 30 05-01 178 058 15 DESCRIPTION Components 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly

More information

all combustible gases and fuel oil, extra light gases up to 1 bar, fuel oil up to 40 bar Fuel Connection gases ½, fuel oil ¼

all combustible gases and fuel oil, extra light gases up to 1 bar, fuel oil up to 40 bar Fuel Connection gases ½, fuel oil ¼ Technical Specification High Velocity Burner Type HV Content 1 Type Designation Code Key Technical Data 3 Deployment and Mode of Operation 4 Basic Construction of the Burner Installation and Startup.1

More information

Tightness control TC. Product brochure GB Edition 12.10

Tightness control TC.  Product brochure GB Edition 12.10 Tightness control TC Product brochure GB 3.1.5. Edition 1.10 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted

More information