Weishaupt oil burners Sizes 30 to 70 1/2003 CA

Size: px
Start display at page:

Download "Weishaupt oil burners Sizes 30 to 70 1/2003 CA"

Transcription

1 Weishaupt oil burners Sizes 0 to 70 1/00 CA

2 Description Weishaupt burners of sizes 0 to 70 were specially designed and developed for industrial applications. The Monoblock-Burners are characterized with multiple excellent features such as: Big firing range and wide area of applications Stable air fan performance excellent combustion characteristics Burner casing can be swung opened Easy to install, setup and maintenance Air damper closed off during burner stop Oil pump and electric oil heater is standard for heavy oil burners Control Control of air and fuel is performed according to the fuel type, burner size and requirement: Two and three stage Oil burners have a nozzle assembly with two or three nozzles. The capacity regulation is controlled by opening or closing the oil solenoid valves and with corresponding changes in air amount. Sliding two stage On sliding two stage regulation, the low fire and high fire points are assigned within the control range. The burner slides depending on heat requirement between both operating points. There is no sudden increase or decrease of supplied fuel amount. Modulation Modulating burners operate according to the heat requirement at any operating point within the control range. Fuel air ratio The regulation of fuel to air ratio varies depending on the burner model: Size 0 Burner models RL and RMS: Pressure side air regulation via ratio controlled sliding sleeve in the mixing head. Burner models L and MS: Pressure side air regulation via adjustable flame tube according to the firing rate. Sizes 0 to 70 Burner models RL and RMS: Pressure side air regulation via ratio controlled sliding sleeve in the mixing head. Burner models L and MS: Diffuser disc according to burner capacity Increased safety via shut off assembly with solenoid valve A proven safety shut off assembly in the nozzle head of oil burner models R... (except RL0) cuts off the oil flow directly at the nozzle during precirculation and when the burner shuts down. Electromagnetic clutch Electromagnetic clutches are available as an option for RL oil burners with post purge (see Special Equipment). Oil circulation on heavy oil burners On heavy oil burners, preheated oil is circulated through the oil lines. This way at the ignition point, the oil in the nozzles has already the correct temperature. Precise oil temperature regulation with Weishaupt oil preheaters Heavy oil burners are equipped with oil preheaters which keep the temperature and thus the viscosity of the oil at the required, predetermined level. This results in uniform atomization and combustion quality. Digital combustion management W-FM100 and W-FM00 combustion manager controls all essential burner functions, e.g. fuel and air supply and monitors the flame with digital precision. The target is optimization of operating conditions, maximization of economical aspect and minimizing the emissions. Thanks to the digital combustion technology, such optimization is available today at reasonable cost. Expenses for installation and maintenance are even clearly lower than with conventional technologies. For example, a separate remote panel is no longer required for burner control. Furthermore, remote operation, remote diagnostic and remote monitoring of the appliances are now realizable. This increases the safety and comfort for operator. Applications The burners can be used with heat exchangers such as hot water boilers, steam boilers, air heaters, and for certain process applications. Due to the fact that the burner is capable of overcoming high combustion chamber pressure, they are most compatible with modern high performance boilers. Fuels Oil section Light oil (# oil), viscosity 6mm /s at 68F (0 C) Medium to heavy oil (# to #6) with viscosity up to 0mm /s at 1F (100 C) Installation sites In standard version (materials, construction, protection), the burners are suitable for use indoors at temperatures between F (-1 C) and 100F (+0 C) and with a maximum relative humidity of 80%. Certification The burners are in compliance with most applicable European and North American standards Outstanding service Weishaupt has a high density sales and service network all over the world. The customer service is available every day around the clock. Optimum in house training conditions ensure high quality of service personnel.

3 Versions Digital combustion manager (W-FM 100) Electronic ratio controller (RVW) with O trim Mechanical linkage Digital combustion manager (W-FM 100) with modulating controller Electronic ratio controller (RVW) with speed control Digital combustion manager (W-FM 100) with modulating controller and speed control Digital combustion management (W-FM 00) with modulating controller O trim and speed control Electronic ratio controller (RVW) with O trim and speed control Standard Special version Capacity regulation Two stage (Z) GHF Sliding two stage (ZM) GHF KLF KLF ZIP On Off On Off Three stage (T) GHF Modulating (ZM) GHF INT ZW TLF On Off HF = High fire INT = Intermediate load LF = Low fire IP = Ignition KLF ZIP On Off Burner model designation RL 0/1 B, vers. ZM Z = Two stage T = Three Stage ZM = Sliding two stage or modulating Index for mixing head Code for capacity range Size Fuel: L = Light Oil, M = Medium Oil, S = Heavy Oil Modulating burner

4 The advantages of digital combustion management Control and Display Unit Digital combustion management means optimal combustion figures, continually reproducible setting figures and ease of use. Weishaupt burners are equipped with electronic ratio controller and digital combustion management to satisfy the requirements of modern combustion technology, which demand a precise and continuously reproducible supply of fuel and combustion air. Only in this way optimal combustion figures can be ensured over extended periods of time. If required, the burners can also be equipped with O trim* and variable speed control. Error free operation via AZL display and control unit Setting and control of the burner functions are achieved using a control and display unit, the AZL, which is equipped with an LCD display. The AZL is connected to the combustion manager via a safety bus system and can be positioned anywhere according to the user s preferences within ft. (100 m) distance from the burner. Flexible communication possibilities The integrated communication interface enables all necessary information and functions to be transmitted to a BMS system. If required, remote operation and remote diagnosis functions, which are accessible via modem, can be installed (e.g. oil/gas change-over, adjustment of setting values). Communication with external systems via Bus. If data has to be exchanged between burners and other heating systems with PLC devices, the information can be accessible via ebus or MODBUS communication system. Integration with building management For control and management functions, Weishaupt offers ProGraf NT - a software product that provides a real time solution to meet all requirements. The price advantage of new technology With improved technology and ease of use, combustion plant is becoming even more economical than ever before. No additional burner controls are required, since this function is already governed by the combustion manager. Fuses and burner motor starter are the only additional items required. Less installation work means less errors: the burners are tested as a complete unit at the factory. If required, the W-FM 100 is available with an integrated modulating controller and variable speed module. No separate equipment is required. The modulating controller and variable speed module are included as standard with the W-FM 00. Commissioning and service work takes less time. The initial presetting of the burner is carried out at the factory. On site, only the site specific operating points have to be adjusted. To facilitate O trim, only an O probe and O module have to be installed and connected with the W-FM 00 via the internal safety bus. * In conjunction with the W-FM 00 combustion manager

5 O probe O module Sliding sleeve Stepping motors Oil regulator Air damper Frequency converter Impulse sender CAN-Bus W-FM 00 combustion manager CAN-Bus Control and Display Unit ebus/ MODBUS BMS visualization ProGraf NT Example of O trim and speed control with W-FM 00

6 Weishaupt RL70/-A oil burner with digital combustion manager 6

7 Weishaupt RMS0/-A oil burner with digital combustion manager 7

8 Proven quality in detail Increased safety via shut off assembly with solenoid valve The electromagnetic actuated safety shut off device isolates the oil supply and return on burner models RL0 to 70 and RMS0 to 70 when the burner shuts down. Oil shut off directly at the nozzle ensures a drip free burner shut down. (Burner model RL0 uses a system without nozzle shut off). Considerable noise reduction due to sound absorbing air inlet Cut-away of a nozzle shut of assembly By utilizing sound absorbing materials on the fan suction side it has been possible to reduce operational noise considerably. Pressure side air regulation via mixing head with ratio controlled sliding sleeve Cut-away of the fan housing The forward and reverse movements of the regulating sleeve in the mixing head ensure that the air supply gap is correct at every operating point throughout the capacity range. This results in optimum velocities over the whole range of regulation. With this system, the mixing pressure is increased at low fire, improving the mixing effect of fuel and air. This results in a reduction in excess air and improved combustion efficiency due to the constant air/fuel ratio. Turn down ratio up to 1: Turn down ratio up to 1: Burner sizes 60 and 70 with pressure side ratio controlled sliding sleeve Burner without pressure side sliding sleeve 8 Example of turn down ratio for different burner models

9 Oil burner selection Models L, RL, MS and RMS0 [ WC ] Burner model L0Z/-A and L0T/-A Combustion head M0/ - 190kx6 MBH Nat. Gas/LPG 1,60 8,0 GPH Light oil # [MBH] 0 1,000,000,000,000,000 6,000 7,000 8,000 [GPH] # [ WC ] Burner model MS0Z/-A Combustion head M0/ - 190kx6 MBH Nat. Gas/LPG,00 8,0 GPH Heavy oil # [MBH] 0 1,000,000,000,000,000 6,000 7,000 8,000 [GPH] # [ WC ] Burner model RL0/-A RMS0/-A Combustion head M0/ - 190kx6 M0/ - 190kx6 MBH Nat. Gas/LPG 1,60 8,0,00 8,0 GPH Light oil # 1 9 Heavy oil # Light oil Heavy oil -1 [MBH] 0 1,000,000,000,000,000 6,000 7,000 8,000 [GPH] # [GPH] # Burner type Version L0Z/-A L0T/-A MS0Z/-A RL0/-A ZM RMS0/-A ZM The ratings given are based on fuel with low calorific value, an air temperature of 68F (0 C) and an installation altitude of 1,60 ft. (00 m). The stated oil throughputs are based on a calorific value of 10,000 BTU/Gal for light oil and 10,000 BTU/Gal for heavy oil Voltages and frequencies: As standard, the burners are suitable for three phase alternating current with voltages available from V, 60Hz. Different voltages and frequency are available on request. Standard burner motor: Isolation class F, IP protection 9

10 Oil burner selection Models L, RL, MS and RMS0 [ WC ] Burner model L0Z/1-B L0Z/1-B Combustion head M0/ - 00x0 M0/ - 17x0 MBH,0 8,70,00-10,170 GPH Light oil # [MBH] 0 1,000,000,000,000,000 6,000 7,000 8,000 9,000 10,00011,0001,000 [GPH] # [ WC ] Burner model MS0Z/1-B MS0Z/1-B Combustion head M0/ - 00x0 M0/ - 17x0 MBH,0 8,70,00-10,170 GPH Heavy oil # [MBH] 0 1,000,000,000,000,000 6,000 7,000 8,000 9,000 10,00011,0001,000 [GPH] # [ WC ] Burner model L0T/1-B L0T/1-B Combustion head M0/ - 00x0 M0/ - 17x0 MBH,0 8,70,60-10,97 GPH Light oil # [MBH] 0 1,000,000,000,000,000 6,000 7,000 8,000 9,000 10,00011,0001,000 [GPH] # [ WC ] Burner model RL0/1-B RMS0/1-B Combustion head M0/ - 190kx6 M0/ - 190kx6 MBH 1,60 9,970,680 9,970 GPH Light oil # 1 71 Heavy oil # [MBH] 0 1,000,000,000,000,000 6,000 7,000 8,000 9,000 10,00011,0001,000 Light oil Heavy oil [GPH] # [GPH] # [ WC] Burner model RL0/-A RMS0/-A Combustion head M0/ - 17kx7 M0/ - 17kx7 MBH Nat. Gas/LPG, 1,600,0 1,600 GPH Light oil # Heavy oil # Light oil Heavy oil -1 [MBH] 0,000,000 6,000 8,000 10,000 1,000 1,000 Burner model Version L0Z/1-B MS0Z/1-B L0T/1-B RL0/1-B ZM RMS0/1-B ZM RL0/-A ZM RMS0/-A ZM [GPH] # [GPH] #

11 Oil burner selection Models L, RL and RMS0 [ WC ] Burner model L0T/-A Combustion head M0/1-18x0 MBH,0 16,6 GPH Light oil # [MBH] 0,000,000 6,000 8,000 10,0001,000 1,000 16,000 18,000 0,000,000 [GPH] # [ WC ] Burner model RL0/1-B RMS0/1-B Combustion head M0/ - 17kx7 M0/ - 17kx7 MBH,0 1,000,80-1,000 GPH Light oil # 17 9 Heavy oil # Light oil Heavy oil -1 [MBH] 0,000,000 6,000 8,000 10,0001,000 1,000 16,000 18,000 0,000,00 [GPH] # [GPH] # [ WC ] Burner model RL0/-A RMS0/-A Combustion head M0/ - 90x18 M0/ - 90x18 MBH,0 16,6 GPH Light oil # 7 10 Heavy oil # [MBH] 0,000,000 6,000 8,000 10,0001,000 1,000 16,000 18,000 0,000,000 Light oil Heavy oil [GPH] # [GPH] # Burner type L0T/-A RL0/1-B RMS0/1-B RL0/-A RMS0/-A Version ZM ZM ZM ZM The ratings given are based on fuel with low calorific value, an air temperature of 68F (0 C) and an installation altitude of 1,60 ft. (00 m). The stated oil throughputs are based on a calorific value of 10,000 BTU/Gal for light oil and 10,000 BTU/Gal for heavy oil Voltages and frequencies: As standard, the burners are suitable for three phase alternating current with voltages available from V, 60Hz. Different voltages and frequency are available on request. Standard burner motor: Isolation class F, IP protection 11

12 Oil burner selection Models RL and RMS60 and 70 [ WC] Burner model RL60/-A RMS60/-A Combustion head M60/ - -0 M60/ - -0 MBH,70,800 6,10,800 GPH Light oil # 176 Heavy oil # [MBH] 0,000 8,000 1,000 16,000 0,000,000 Light oil Heavy oil [GPH] # [GPH] # [ WC] Burner model RL70/-A RMS70/-A Combustion head M70/1a M70/1a MBH 6,00 7,00 6,910 7,00 GPH Light oil # 6 6 Heavy oil # [MBH] 0 6,000 1,000 18,000,000 0,000 6,000 Light oil Heavy oil [GPH] # [GPH] # [ WC] Burner model RL70/1-A RMS70/1-A Combustion head M70/1a M70/1a MBH 6,00 9,86 6,910 9,86 GPH Light oil # 6 1 Heavy oil # [MBH] 0 6,000 1,000 18,000,000 0,000 6,000 Light oil Heavy oil [GPH] # [GPH] # Burner type RL60/-A RMS60/-A RL70/1-A RMS70/1-A RL70/-A RMS70/-A Version ZM ZM ZM ZM ZM ZM The ratings given are based on fuel with low calorific value, an air temperature of 68F (0 C) and an installation altitude of 1,60 ft. (00 m). The stated oil throughputs are based on a calorific value of 10,000 BTU/Gal for light oil and 10,000 BTU/Gal for heavy oil Voltages and frequencies: As standard, the burners are suitable for three phase alternating current with voltages available from V, 60Hz. Different voltages and frequency are available on request. Standard burner motor: Isolation class F, IP protection 1

13 Scope of delivery Description L0 MS0 RL0 RMS0 L0 MS0 RL0 RMS0 RL60 RMS60 L0 RL0 RMS0 RL70 RMS70 Burner housing, hinged flange, housing cover, Weishaupt burner motor, air regulation housing, fan wheel, combustion head, ignition unit, ignition cable, ignition electrodes, nozzle assembly with oil nozzle(s), combustion manager with control unit, flame sensor, flange gasket, limit switch on hinged flange, fixing bolts W-FM 100 combustion manager Air pressure switch Oil pressure switch in return line Servomotor for direct control of the air damper Adjustable regulating sleeve in the mixing head Ratio controlled sliding sleeve in the mixing head Integral oil pump ➀ Integral oil preheater ➀ Oil hoses oil solenoid valves, 1 safety valve, two stage nozzle assembly without shut off ➁ ➁ oil solenoid valves, 1 safety valve, three stage nozzle assembly without shut off ➂ ➂ oil solenoid valves in flow and return, nozzle assembly without shut off 1 solenoid valve in flow and return, nozzle assembly with shut off (solenoid on RL & RMS, hydraulically controlled ball valve on MS) 1 solenoid valve in flow and return, bypass solenoid valve, nozzle assembly with solenoid shut off ➀ RMS type burners require separate pump and preheater stations (refer to pages 0-) ➁ Types L0Z and L0Z only ➂ Types L0T, L0T and L0T only 1

14 Special equipment Sizes 0 and 0 Description L0Z L0T MS0Z RL0 RMS0 L0Z L0T MS0Z RL0 RMS0 Vertically firing burner version standard standard standard standard standard Air intake flange for connection of an air duct Size Size Oil meter VZO0 installed Size Size Pump J7 in lieu of J TA in lieu of J6 Size E6 in lieu of J (for ring main pressure > 9 PSI (.0 bar) E7 in lieu of J (for ring main pressure > 9 PSI (.0 bar) Oil hoses DN1 / 1 (100mm) in lieu of 0 (1000mm) Heated stainless steel Pressure gauge with ball valve 0 bar bar Vacuum gauge with ball valve -1 9 bar Electromagnetic clutch Size Size Combustion head extension 6 (10 mm) Size 0/ Size 0/ Size 0/ (00 mm) Size 0/ Size 0/ Size 0/ W-FM 100 with integrated modulating controller Oil preheater WEV in lieu of EVD Size WEV in lieu of EVD Size MV9C oil preheater (medium) in addition to standard Size integral electric oil preheater Size Fittings medium preheater station in conjunction with electric preheater screwed for warm water up to 0F (110 C) flanged for warm water up to 0F (110 C) flanged for hot water from 0F (110 C) up to F (180 C) screwed for low pressure steam up to 7. PSI (0. bar) screwed for high pressure steam up to 1.7 PSI (1. bar) flanged for high pressure steam from 1.7 PSI (1. bar) up to 17. PSI (1 bar) flanged for high pressure steam from 17 PSI (1 bar) up to 90 PSI (0 bar) flanged for high pressure steam from 90 PSI (0 bar) up to 6. PSI ( bar) flanged for thermal fluid up to 80 F (0 C) flanged for thermal fluid up to 70 F (00 C)

15 Special equipment Size 0 Description L0T RL0 RMS0 Vertically firing burner version standard standard standard Air intake flange for connection of an air duct Oil hoses Heated stainless steel Pressure gauge with ball valve 0 0 bar Vacuum gauge with ball valve -1 9 bar Combustion head extension 6 (10 mm) Size 0/ Size 0/ (00 mm) Size 0/ Size 0/ W-FM 100 with integrated modulating controller Oil preheater WEV in lieu of WEV Size 0/ MV9C oil preheater (medium) in addition to standard Size integral electric oil preheater Size Fittings medium preheater station in conjunction with electric preheater screwed for warm water up to 0 F (110 C) flanged for warm water up to 0 F (110 C) flanged for hot water from 0 F (110 C) up to F (180 C) screwed for low pressure steam up to 7. PSI (0. bar) screwed for high pressure steam up to 1.7 PSI (1. bar) flanged for high pressure steam from 1.7 PSI (1. bar) up to 17. PSI (1 bar) flanged for high pressure steam from 17 PSI (1 bar) up to 90 PSI (0 bar) flanged for high pressure steam from 90 PSI (0 bar) up to 6. PSI ( bar) flanged for thermal fluid up to 80 F (0 C) flanged for thermal fluid up to 70 F (00 C)

16 Special equipment Sizes 60 and 70 Description RL60 RMS60 RL70 RMS70 Vertically firing burner version standard standard standard standard Air intake flange for connection of an air duct Oil hoses Heated stainless steel Pressure gauge with ball valve 0 0 bar Vacuum gauge with ball valve -1 9 bar Electromagnetic clutch Combustion head extension 6 (10 mm) (00 mm) W-FM 100 with integrated modulating controller

17 Pump and preheater stations Description Scope of delivery - pump stations Pump unit (screw spindle pump with motor), pressure gauge, vacuum gauge, pressure regulating valve, ball valves, suction flange, pressure flange including counter flanges, screws and washers, suction-side filter. All parts fully assembled on an oil drip tray. The pump station is available in two different versions - either as a single station unit with one pump, or as a twin station unit with two pumps, one pump being a backup unit. Should one of the pump fail, it is possible to quickly switch over to the other one. Only proven makes of pump are used. The pumps are carefully matched to the capacity of the burner. Scope of delivery - preheater stations Preheater stations are supplied fully assembled on an oil drip tray. The preheater ensures a constant oil temperature and as result, the appropriate viscosity of the fuel oil. There are two basic versions of the preheater station available: 1. Electric preheating (model WEV...). Medium preheating (model MV...) MV.. medium oil preheater Medium preheaters are high capacity, forced circulation heat exchangers. High capacity is achieved with a compact, space saving construction. Hot water, steam or thermo fluid can be used as heating medium. The oil preheaters guarantee substantially stable oil temperatures and thus good combustion figures. The oil temperature achieved depends on the heating medium used. When selecting and sizing, please refer to the oil temperature diagrams in chapter. of the technical brochure Weishaupt electric and medium oil preheaters, print No. 18. Weishaupt medium oil preheaters can be used universally. It is possible to change the medium at any time. The medium preheater can be used either as stand alone unit or in conjunction with an electric oil preheater. If operating steam at more than 110 PSI (7. bar) or hot water between F (180 C) and 90F (00 C) is continuously available, then an electric preheater is not required. This is also possible if plant with the above minimum pressures or temperatures to be operated with light oil or gas. If the medium temperature is not sufficient to adequately preheat the fuel oil, then the electric oil preheater inputs the additional heat required. The electric oil preheater heats the oil for the start up of the plant. If the required medium temperature is available then the station switches over to the medium oil preheater thus saving on electricity. Suitable connection types for medium oil preheaters can be selected, depending on the medium available. If medium oil preheaters are provided without electric oil preheaters, a mechanical temperature regulator must be used with the medium connection fittings. Air / gas separators or oil circulation tanks Patented air / gas separators or circulation tanks are always required and must be quoted with the burner. By using an air / gas separator or circulation tank, it is possible for the preheated oil from the burner return to be mixed with oil from the burner supply line. This results in an energy saving, as it is only necessary to partially heat the fuel oil. Where one burner is operating on light oil, it is then possible to use a two pipe system so long as the suction vacuum does not exceed 6 PSI (0. bar). If several burners with air / gas separators or oil circulation tanks are being supplied by a ring main system, then it is a good idea to provide a manually actuated double shut off device with limit switch immediately after the air / gas separator or circulation tank. The air / gas separator or circulation tank must be selected according to the ring main pump rating and the burner size. When choosing ring main pump units, please ensure that the capacity is around 1. - times of the nozzle rating. General instructions When starting a boiler from a cold condition with residual oil, the capacity of electric oil preheater must be at least 0% of the boiler rating. On hot water boilers up to 6F (10 C) operating temperature, the electric oil preheaters must be able to produce the full boiler output without utilizing medium preheaters. Use of a medium preheater is not suitable for medium temperatures below 1F (100 C). The number of media oil preheaters to be selected depends on the oil throughput and can be taken from the capacity charts (see the technical brochure Weishaupt electric and media oil preheaters ). Planning and installation instructions Air /Gas separator, circulation tank, pump station and oil preheater station must be installed close to the burner as possible. On RGMS type burners, sizes 60 and 70, the time required for oil circulation during start sequence depends on the length of the pipework between the burner and the air gas separator or circulation tank. The shorter the pipeline, the shorter the period between call for heat and oil release / burner start after a controlled shutdown. 17

18 Pump and preheater stations Types Pump stations - 60 Hz frequency Burner Technical data - pump Version with 1 pump Version with pumps capacity Supply at Speed Motor at Pump type Order No. Pump type Order No. in GPH 10 mm /s rpm 0 mm /s GPH (l/h) HP (kw) (100) 00 (.) SPF SPZ (00) 00. (.6) SPF SPZ (70) 00. (.0) SPF SPZ Preheater stations Type Number Medium preheater Electric preheater Order No. lbs/h (kg/h) at t = 1F (7 C) WEV.1/ GPH (7 kg/h) WEV.1/01 00 GPH (70 kg/h) WEV/ GPH (00 kg/h) WEV/01 66 GPH (1000 kg/h) MV9C with temperature contr (00) MV9C without temperature contr (00) MV10A with temperature contr (1000) MV10A without temperature contr (1000) Connection fittings for preheater stations with 1 oil preheater Description Order No. Fittings for MV9C medium preheater station (with electric preheater stations) screwed for warm water up to 0F (110 C) screwed for high pressure steam up to 1.7PSI (1. bar) screwed for high pressure steam from 1.7PSI (1. bar) up to 17.PSI (1 bar) flanged for warm water up to 0F (110 C) flanged for hot water from 0F (110 C) up to F (180 C) flanged for high pressure steam up to 1.7PSI (1. bar) flanged for high pressure steam from 87PSI (6 bar) up to 90PSI (0 bar) flanged for high pressure steam from 90PSI (0 bar) up to 6PSI ( bar) flanged for thermal fluid up to 80F (0 C) flanged for thermal fluid up to 70F (00 C) Fittings for MV9C medium preheater station (with thermostat valve. without electric preheater) flanged for hot water from F (180 C) up to 90F (00 C) flanged for high pressure steam from 109PSI (7. bar) up to 188.PSI (1 bar) flanged for high pressure steam from 188.PSI (1 bar) up to 90PSI (0 bar) flanged for high pressure steam from 90PSI (0 bar) up to 6PSI ( bar) flanged for thermal fluid from 90F (00 C) up to 80F (0 C) flanged for thermal fluid from 80F (0 C) up to 70F (00 C) Fittings for MV10A medium preheater station (with electric preheater stations) screwed for warm water up to 0F (110 C) screwed for high pressure steam up to 1.7PSI (1. bar) screwed for high pressure steam from 1.7PSI (1. bar) up to 17.PSI (1 bar) flanged for warm water up to 0F (110 C) flanged for hot water from 0F (110 C) up to F (180 C) flanged for high pressure steam up to 1.7PSI (1. bar) flanged for high pressure steam from 87PSI (6 bar) up to 90PSI (0 bar) flanged for high pressure steam from 90PSI (0 bar) up to 6PSI ( bar) flanged for thermal fluid up to 80F (0 C) flanged for thermal fluid up to 70F (00 C) Fittings for MV10A medium preheater station (with thermostat valve, without electric preheater) flanged for hot water from F (180 C) up to 90F (00 C) flanged for high pressure steam from 109PSI (7. bar) up to 188.PSI (1 bar) flanged for high pressure steam from 188.PSI (1 bar) up to 90PSI (0 bar) flanged for high pressure steam from 90PSI (0 bar) up to 6PSI ( bar) flanged for thermal fluid from 90F (00 C) up to 80F (0 C) flanged for thermal fluid from 80F (0 C) up to 70F (00 C)

19 Pump station (with pumps) Medium preheater station Electric preheater station Possible connections of medium preheater HW outlet HW inlet Hot water Medium preheater Electric preheater HW outlet Thermo fluid outlet Brenner- Anschluß HW inlet Thermo fluid inlet Hot water and thermo fluid Steam inlet Condensate outlet Low pressure steam up to 1.7 PSI (1. bar) Mechanically connected shut off assembly with limit switch and safety valve Air/gas separator Mechanically connected shut off assembly with limit switch and safety valve Description The connection fittings are to be chosen depending on the available medium and the number of preheaters. Condensate outlet Included with pump station Included with preheater Preheater (not included in delivery) Condensate sight glass Steam trap HPS inlet High pressure steam up to 17. PSI (1 bar) Accessories Lines shown in black to be provided on site Ball valve Regulator Filter Pressure gauge Diagram - separate pump and preheater stations 19

20 Technical data Size 0 Technical data L0Z/-A L0T/-A MS0Z/-A Burner motor Model D11/110- D11/110- D11/110- Motor rating HP (kw) 6.7 (.0) 6.7 (.0) 6.7 (.0) Full Load Amps (FLA) at 60 V A Speed (60 Hz) rpm Fan wheel colour / ø red / 8 x 100 red / 8 x 100 red / 8 x 100 Combustion manager Model W-FM100 W-FM100 W-FM100 Ignition unit Model W-ZG0/ W-ZG0/ W-ZG0/ Servomotor Air Model SQM SQM SQM Fuel Model Mixing head Model Integral pump Model J6/J7 ➀ J6/J7 ➀ E7 Oil preheater Model EVD Oil throughput GPH (kg/h) 7 (70) Heating capacity kw 1. Oil solenoid valve 110V 1/ 0 W Model 11K 60 11K60 110V 1/8 19 W Model 11 K () 11 K () 11 K 110V 1/8 19 W Model 1 K 91 V 1/ (supply) 0 W Model V 1/8 (return) 0 W Model V /8 (supply) 0 W Model 1 H V /8 (return) 0 W Model 11 G 0 Oil pressure 1 10 bar (light oil return - bar) Model switch 1 10 bar (heavy oil return - 7 bar) Model DSA 6 F001 Oil hoses DN / Length 1/0 (1000mm) 1/0 (1000mm) 0/0 (1000mm) (High pressure metal hoses for MS, RMS and RGMS) 0/1 (100mm) Burner weight lbs (kg) 198. (90) 0 (9) 97 (1) Technical data RL0/-A RMS0/-A Burner motor Model D11/110- D11/110- Motor rating HP (kw) 6.7 (.0) 6.7 (.0) Full Load Amps (FLA) at 60 V A Speed (60 Hz) rpm Fan wheel colour / ø red / 8 x 100 red / 8 x 100 Combustion manager Model W-FM100 W-FM100 Ignition unit Model W-ZG0/ W-ZG0/ Servomotor Air Model SQM SQM Fuel Model SQM SQM Mixing head Model SQM SQM Integral pump Model TA TA Oil preheater Model EVD Oil throughput GPH (kg/h) 7 (70) Heating capacity kw 1. Oil solenoid valve V 1/ (supply and return) 0 W Model 11 K 60 V 1/8 (supply and return) 0 W Model 11 K V /8 (supply) 0 W Model 1 H V /8 (return) 0 W Model 11 G 0 Oil pressure 1 10 bar (light oil return EL - bar) Model DSA 6 F001 switch 1 10 bar (heavy oil return S - 7 bar) Model DSA 6 F001 Oil hoses DN / Length 0/0 (1000mm) 0/0 (1000mm) (High pressure metal hoses for MS, RMS and RGMS) 0/1 (100mm) Burner weight lbs (kg) 0 (100) 90 (10) 0

21 Technical data Size 0 Technical data L0Z/1-B L0T/1-B MS0Z/1-B Burner motor Model D11/10- D11/10- D11/10- Motor rating HP (kw) 10. (7.8) 10. (7.8) 10. (7.8) Full Load Amps (FLA) at 60 V A Speed (60 Hz) rpm Fan wheel colour / ø red / 7 x 100 red / 7 x 100 red / 7 x 100 Combustion manager ➀ Model W-FM100 W-FM100 W-FM100 Ignition unit Model W-ZG0/ W-ZG0/ W-ZG0/ Servomotor Air Model SQM SQM SQM Fuel Model Mixing head Model Integral pump Model J6/J7 ➀ J6/J7/TA ➀➁ E7 Oil preheater Model EVD Oil throughput GPH (kg/h) 7 (70) Heating capacity kw 1. Oil solenoid valve 110V 1/ 0 W Model 11K 60 11K60 110V 1/8 19 W Model 11 K () 11 K () 11 K 110V 1/8 19 W Model 1 K 91 V 1/ (supply) 0 W Model V 1/8 (return) 0 W Model V /8 (supply) 0 W Model 1 H V /8 (return) 0 W Model 11 G 0 Oil pressure 1 10 bar (light oil return - bar) Model switch 1 10 bar (heavy oil return - 7 bar) Model DSA 6 F001 Oil hoses DN / Length 1/0 (1000mm) 1/0 (1000mm) 0/0 (1000mm) ( High pressure metal hoses for MS, RMS and RGMS) 0/1 (100mm) Burner weight lbs (kg) 98 (1) 98 (1) (160) Technical data RL0/1-B RMS0/1-B RL0/-A RMS0/-A Burner motor Model D11/10- D11/10- Motor rating HP (kw) 10. (7.8) 10. (7.8) Full Load Amps (FLA) at 60 V A Speed (60 Hz) rpm 0 0 Fan wheel colour / ø red / 7 x 100 red / 7 x 100 Combustion manager Model W-FM100 W-FM100 Ignition unit Model W-ZG0/ W-ZG0/ Servomotor Air Model SQM SQM Fuel Model SQM SQM Mixing head Model SQM SQM Integral pump Model TA TA Oil preheater Model EVD ➂➃ Oil throughput GPH (kg/h) 7 (70) Heating capacity kw 1. Oil solenoid valve V /8 (supply) 0 W Model 1 H 1 H V /8 (return) 0 W Model 11 G 0 11 G 0 Oil pressure 1 10 bar (light oil return - bar) Model DSA 6 F001 switch 1 10 bar (heavy oil return - 7 bar) Model DSA 6 F001 Oil hoses DN / Length 0/0 (1000mm) 0/0 (1000mm) ( High pressure metal hoses for MS, RMS and RGMS) 0/1 (100mm) Burner weight lbs (kg) 1 (1) 66 (166) ➀ ➁ ➂ ➃ Light oil burners > 60 GPH (00 kg/h): oil pump J7 in lieu of J6 (refer to Special Equipment for additional cost) Light oil burners > 7 GPH (0 kg/h): oil pump TA in lieu of J6 (refer to Special Equipment for additional cost) Heavy oil burners > 7 GPH (70 kg/h): oil preheater WEV. in lieu of EVD (refer to Special Equipment for additional cost) Heavy oil burners > 8. GPH (00 kg/h): oil preheater WEV in lieu of WEV. (refer to Special Equipment for additional cost) Note: If the flow pressure exceeds 9 PSI (.0 bar) then pump types E6 and E7 must be used in lieu of J6 and J7 respectively 1

22 Technical data Size 0 Technical data L0T/-A RL0/1-B RL0/-A Burner motor Model D1/170- D1/170-a D1/170- Motor rating HP (kw) 0 (1) 1 (10.) 0 (1) Full Load Amps (FLA) at 60 V A Speed (60 Hz) rpm Fan wheel colour / ø red / 0 x 100 red / 0 x 100 red / 0 x 100 Combustion manager Mode; W-FM100 W-FM100 W-FM100 Ignition unit Model W-ZG0/ W-ZG0/ W-ZG0/ Servomotor Air Model SQM SQM SQM Fuel Model SQM SQM Mixing head Model SQM SQM Integral pump Model TAC TAC TC Oil preheater Model Heating capacity GPH (kg/h) Heating capacity kw Oil solenoid valve 110V 1/ 0 W Model 11K V 1/8 19 W Model 11 K () 110V 1/8 19 W Model V /8 (supply) 0 W Model 1 H 1 H V /8 (return) 0 W Model 11 G 0 11 G 0 Oil pressure 1 10 bar (light oil return - bar) Model DSA 6 F001 DSA 6 F001 switch 1 10 bar (heavy oil return - 7 bar) Model Oil hoses DN / Length 0/1 (100mm) /1 (100mm) /1 (100mm) ( High pressure metal hoses for MS, RMS and RGMS) Burner weight lbs (kg) 1 (00) 9 (08) 6 (10) Technical data RMS0/1-B RMS0/-A Burner motor Model D1/170-a D1/170- Motor rating HP (kw) 1 (10.) 0 (1) Full Load Amps (FLA) at 60 V A 17.. Speed (60 Hz) rpm Fan wheel colour / ø red / 0 x 100 red / 0 x 100 Combustion manager Model W-FM100 W-FM100 Ignition unit Model W-ZG0/ W-ZG0/ Servomotor Air Model SQM SQM Fuel Model SQM SQM Mixing head Model SQM SQM Integral pump model TAC TC Oil preheater Model WEV./01 ➀ WEV/01 Oil throughput GPH (kg/h) 80 (00) 1 (00) Heating capacity kw 1.8. Oil solenoid valve V /8 (supply) 0 W Model 1 H 1 H V /8 (return) 0 W Model 11 G 0 11 G 0 Oil pressure 1 10 bar (light oil return - bar) Model switch 1 10 bar (heavy oil return - 7 bar) Model DSA 6 F001 DSA 6 F001 Oil hoses DN / Length / (110mm) / (110mm) ( High pressure metal hoses for MS, RMS and RGMS) /9 (100mm) /9 (100mm) Burner weight lbs (kg) 7 (8) (0) ➀ Heavy oil burners > 8. GPH (00 kg/h): oil preheater WEV in lieu of WEV. (refer to Special Equipment for additional cost)

23 Technical data Sizes 60 and 70 Technical data RL60/-A RMS60/-A Burner motor Model D1/170- D1/170- Motor rating HP (kw) 0 (1) 0 (1) Full Load Amps (FLA) at 60 V A.. Speed (60 Hz) rpm Fan wheel colour / ø red / 6 x 10 red / 6 x 10 Combustion manager Model W-FM100 W-FM100 Ignition unit Model W-ZG0/ W-ZG0/ Servomotor Air Model SQM SQM Fuel Model SQM SQM Mixing head Model SQM SQM Integral pump Model TC Oil solenoid valve V /8 (supply) 0 W Model 1 H 1 H V /8 ( return) 0 W Model 11 G 0 11 G 0 110V /8 (bypass) 19 W Model H 706 Oil pressure bar (flow - bar) Model DSA 8 F 001 switch 1 10 bar ( light oil return - bar) Model DSA 6 F bar (heavy oil return - bar) Model DSA 6 F 001 Oil hoses DN / Length /1 (100mm) 16/ (110mm) ( High pressure metal hoses for MS, RMS and RGMS) 16/9 (100mm) Burner weight lbs (kg) (0) 6 (10)* * Weight excluding pump station and preheater station Technical data RL70/1-A RL70/-A RMS70/1-A RMS70/-A Burner motor Model D160/1-a D160/1- D160/1-a D160/1- Motor rating HP (kw) 1. (16) 9. () 1. (16) 9. () Full Load Amps (FLA) at 60 V A Speed (60 Hz) rpm Fan wheel colour / ø yellow /7x18 green /0x10 yellow /7x18 green /0x10 Combustion manager Model W-FM100 W-FM100 W-FM100 W-FM100 Ignition unit Model W-ZG0/ W-ZG0/ W-ZG0/ W-ZG0/ Servomotor Air Model SQM SQM SQM SQM Fuel Model SQM SQM SQM SQM Mixing head Model SQM SQM SQM SQM Integral pump Model TC (< 17 GPH) TC (< 17 GPH) (< 600 kg/h) (< 600 kg/h) Model TC (> 17 GPH) TC (> 17 GPH) (> 600 kg/h) (> 600 kg/h) Oil solenoid valve V 1/ (supply) 0 W Model 1 H 1 H 1 H 1 H V 1/ ( return) 0 W Model 11 G 0 11 G 0 11 G 0 11 G 0 110V /8 (bypass) 19 W Model H 706 H 706 Oil pressure bar (supply - 18 bar) Model DSA 8 F 001 DSA 8 F 001 switch 1 10 bar ( light oil return - bar) Model DSA 6 F 001 DSA 6 F bar (heavy oil return - 7 bar) Model DSA 6 F 001 DSA 6 F 001 Oil hoses DN / Length /1 (100mm) /1 (100mm) 0/ (110mm) 0/ (110) ( High pressure metal hoses for MS, RMS and RGMS) 0/9 (100mm) 0/9 (100) Burner weight lbs (kg) 77 (0) 77 (0) 68 (10)* 68 (10)* * Weight excluding pump station and preheater station

24 Dimensions Sizes 0 and 0 l 6 h 6 d 1 b 6 b 7 b h 1 h l 8 h b b 8 d b r b b 1 h l 7 l r 1 l9 l10 d l d l l 1 d 6 d Size Dimensions in inches (mm) l 1 l l l l 6 l 7 l 8 l 9 l 10 b 1 ➀ b b b b L to RMS0/-A (89) () (0) (8) () (1) (7) (10) (198) (787) (697) (71) (08) (18) L to.1(10) 7.8(198) RMS0/1-A (97) (69) (0) (8) (1) (10) (7) (17) ➀ () ➁ (89) (79) (01) () (6).1(10) 7.8(198) RL / RMS0/-A (97) (69) (61) (8) (1) (10) () (17) ➀ () ➀ (89) (79) (01) () (6).6 1. (117) ➁ (1) ➁ b 6 b 7 b 8 h 1 h h h h 6 d 1 d d d d d 6 r 1 r L to M RMS0/-A (19) (0) ( 0) (7) (07) (07) (6) ( 0) (80) (0) (18) (M1) (60) (8) (90) (890) L to (19) (0) (6) RMS0/1-B M (7) ➀ (60) ➀ ( 70) (607) (11) () (191) ➀ ( 70) (80) (0) (18) (M1) (60) (8) (1100) (970) RL / (19) (0) (6) RMS0/-A M (7) ➀ (60) ➀ ( 70) (607) (11) () (191) ➀ ( 70) (0) (90) (18) (M1) (00) () (1100) (970) (9) ➁ (7) ➁ (0) ➁ ➀ ➁ Dimension valid for medium and heavy oil burners in conjunction with WEV. oil preheater (refer to Special Equipment for additional cost) Dimension valid for medium and heavy oil burners in conjunction with WEV oil preheater (refer to Special Equipment for additional cost) Size 0 and 0 burners on twin flue boilers It should be taken into account at the planning stage that the burners must be at least 6 (900 mm) apart from each other. This ensures a minimum gap of 1.6 (0 mm) between the burners when the largest pump and motor types are fitted. All measurements are approximate. Weishaupt reserves the right to make alterations in light of future developments.

25 Dimensions Size 0 l 6 h 6 d 1 b 6 b 7 b h l 8 h h 1 b b 8 d b r b b 1 h l 7 l r 1 l9 l10 d l d l l 1 d 6 d Size L0T/-A R..0/1-B R..0/-A L0T/-A R...0/1-B R..0/-A Dimensions in inches (mm) l1 l l l l6 l7 l8 l9 l10 b1➀ b b b b b6 b7 b (990) (1) (7) (8) () (1) (67) (961) (88) (6) 77 0 ( 0) (17) () (7) (60) (98) (1) (61) (8) () (18) () (1)➀ (1)➀ (96) (8) (0) (77) (0) (9)➀ (7)➀ ( 0) (990) (1) (86) (8) () (1) (67) (17) (1) (96) (88) (6) (77) (0) (9) (7) ( 0) h1 h h h h6 d1 d d d d d6 r1 r M (78) (6) (1) ( 0) (80) (80) (8) (M16) (80) (90) (1100) (10) 7. (191) M (78) (6) (1) (0)➀ ( 0) (0) (90) (8) (M1) (00) (0) (1100) (1000) M (78) (6) (1) (0) ( 0) (80) (0) (8) (M16) (80) (90) (1100) (10) ➀ Dimension valid for medium and heavy oil burners in conjunction with WEV oil preheater (refer to Special Equipment for additional cost) Size 0 burners on twin flue boilers It should be taken into account at the planning stage that the burners must be at least 0 (100 mm) apart from each other. This ensures a minimum gap of 1.6 (0 mm) between the burners when the largest pump and motor types are fitted. All measurements are approximate. Weishaupt reserves the right to make alterations in light of future developments.

26 Dimensions Sizes 60 and 70 l6 h d 1 b h 1 h l 8 b b 8 d r b b 1 l7 h 0 0 l l l 1 r1 d l b l 1 d d 6 d Size- Dimensions in inches (mm) l1 l l l l6 l7 l8 b1 b b b b b8 RL60/-A RMS60/-A (1189) (0) (07) (8) (0) (180) (6) (1070) (966) (87) (80) (670) (0) RL RMS70 (168) (8) (17) (8) (61) () (6) (17) (1166) (60) (0) (760) (90) h1 h h h d1 d d d d d6 r1➀ r RL60/-A M RMS60/-A (90) (60) (670) (0) (9) (00) (8) (M16) (70) () (160) (110) RL M RMS70 (107) (0) (77) (600) (70) (80) (10) (M16) (0) (00) (100) (110) ➀ With electromagnetic clutch Dimensions b1, b and b are reduced by 1.8 ( mm) for burner size 70/1. Size 60 and 70 burners on twin flue boilers It should be taken into account at the planning stage that the burners must be at least. (110 mm) for RL60 or (1 mm) for RL70 apart from each other. This ensures a minimum gap of 1.6 (0 mm) between the burners when the largest pump and motor types are fitted. All measurements are approximate. Weishaupt reserves the right to make alterations in light of future developments. 6

27 Burner fuel systems Models L0Z/L0Z Models L0T / L0T / L0T Models RL0/RL a 16b a 16b V V 11V V P M 1a 1a 1a 1a 1a 1 Models MS0Z/MS0Z a Model RL b Models RMS0 to RMS0 Integral pump and preheater a 16 ϑ 11V V 11V V P 11V V 11V V 11V V 11V V P M 11V V 11V V P M 1a 1a 1b 1c 1a 1a 1 1a 1a 1a 1 Models RL60/RL V 11V 11V V P M 1a 1a 1 Models RMS60/RMS70 With separate pump and preheater stations b ϑ 1a P 11V V ϑ 11V V P 18 1a M 1 Legend 10 Oil pump 11 Oil filter 1 Normally closed oil solenoid valve ( V, electrically connected in series with 1a) 1a Normally closed oil solenoid valve ( V, electrically connected in series with 1, fitted against the direction of flow) 1b Normally open bypass oil solenoid valve 1 Normally closed oil solenoid valve 1a Normally closed oil solenoid valve for stages 1, and 1b Normally open oil solenoid valve (stage 1) 1c Normally closed oil solenoid valve (stage ) 1 Oil pressure switch in flow 1a Oil pressure switch in return 1 Oil regulator 16 Nozzle assembly with shut off device (solenoid valve) 16a Nozzle assembly with shut off device 16a Nozzle assembly without shut off device 17 Oil preheater 18 Pt100 temperature sensor (to monitor minimum oil temperature) 18a Thermostat 7

28 Product and customer service the complete Weishaupt range Weishaupt Corporation 680 Danville Road Mississauga, ON LT H7 Ph.: (90) 6 096, Fax.: (90) Print No , August 00 Printed in Germany. All rights reserved. Regular maintenance reduces heating costs and environmental pollution. Only a properly adjusted burner can save energy and be environmentally friendly. Behind each Weishaupt burner stands the whole Weishaupt customer service organization. The outstanding efforts made in maintenance and service justify the enormous trust placed in Weishaupt s burners, for at Weishaupt product and customer service belong together. Weishaupt customer service is there for you all year round. Whenever you need help, be it the supply of spare parts, technical advice or a site visit. We are there when you need us.

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 CA 1 Description, Types of regulation, Model overview Weishaupt Monarch oil burners are of the fully automatic pressure atomizing type. Their design has

More information

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable

product Information on oil, gas and dual fuel burners Industrial burners 1,000 11,700 kw flexible and reliable product Information on oil, gas and dual fuel burners Minimale Industrial Emissionswerte burners mit Gas Industrial burners 1, 11,7 kw flexible and reliable Weishaupt Industrial Burners: Flexible and reliable

More information

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 GB

Weishaupt Monarch oil burners Sizes 5 to 11 1/2002 GB Weishaupt Monarch oil burners Sizes 5 to 11 1/ GB 1 Description, Types of regulation, Model overview Weishaupt Monarch oil burners are of the fully automatic pressure atomising type. Their design has been

More information

Weishaupt gas burners Sizes 30 to 70 Version NR (NO x reduced)

Weishaupt gas burners Sizes 30 to 70 Version NR (NO x reduced) Weishaupt gas burners Sizes 30 to 70 Version NR (NO x reduced) Description Weishaupt industrial burners, sizes 30 to 70, have been especially designed for industrial capacity ranges. The monobloc burners

More information

product Oil burners, 1-11 monarch burners, sizes 1-11 ( kw) simply reliable Information on oil burners

product Oil burners, 1-11 monarch burners, sizes 1-11 ( kw) simply reliable Information on oil burners product Information on oil burners Oil burners, 1-11 monarch burners, sizes 1-11 (7-5 kw) simply reliable Description Weishaupt Monarch burners are of the fully automatic, pressure atomising type. Their

More information

Weishaupt Monarch oil burners Sizes 1 and 3 1/2002 GB

Weishaupt Monarch oil burners Sizes 1 and 3 1/2002 GB Weishaupt Monarch oil burners Sizes 1 and 3 1/ GB Description Weishaupt Monarch oil burners are of the fully automatic pressure atomising type. Their design has been carefully considered down to the smallest

More information

product WM 10 oil, gas and dual fuel version Weishaupt monarch WM10 burners flexible application Information on oil, gas and dual fuel burners

product WM 10 oil, gas and dual fuel version Weishaupt monarch WM10 burners flexible application Information on oil, gas and dual fuel burners product Information on oil, gas and dual fuel burners WM 10 oil, gas and dual fuel version Weishaupt monarch WM10 burners flexible application Advanced technology starts from tradition The new monarch

More information

product WM 20 for oil, gas and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on oil, gas and dual-fuel burners

product WM 20 for oil, gas and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on oil, gas and dual-fuel burners product Information on oil, gas and dual-fuel burners WM 20 for oil, gas and dual-fuel WM 20 monarch burners (150 2600 kw) compact and powerful Progress and tradition: The latest monarch burner The monarch

More information

Weishaupt WKGL70 dual fuel burner Version 3LN (Low NO x ) multiflam 1/2003 GB

Weishaupt WKGL70 dual fuel burner Version 3LN (Low NO x ) multiflam 1/2003 GB Weishaupt WKGL70 dual fuel burner Version 3LN (Low NO x ) multiflam 1/2003 GB Description Weishaupt WK series industrial burners have been especially designed for industrial capacity ranges. The construction

More information

product Digital combustion technology Weishaupt oil burners, WL10 to WL40 ( kw) Information on compact burners

product Digital combustion technology Weishaupt oil burners, WL10 to WL40 ( kw) Information on compact burners product Information on compact burners Digital combustion technology Weishaupt oil burners, WL1 to WL4 (3 7 kw) Hot for quality Technological progress is our motivation. It has been driving us for more

More information

product Compact and powerful Weishaupt monarch oil burner, WM-L20 ( kw) Information on oil burners

product Compact and powerful Weishaupt monarch oil burner, WM-L20 ( kw) Information on oil burners product Information on oil burners Compact and powerful Weishaupt monarch oil burner, WM-L20 (400 2600 kw) Progress and tradition: The new monarch oil burner For more than 50 years the monarch trademark

More information

product WM 30 for gas, oil, and dual-fuel WM 30 monarch burners ( kw) powerful and versatile Information on gas, oil, and dual-fuel burners

product WM 30 for gas, oil, and dual-fuel WM 30 monarch burners ( kw) powerful and versatile Information on gas, oil, and dual-fuel burners product Information on gas, oil, and dual-fuel burners WM 30 for gas, oil, and dual-fuel WM 30 monarch burners (350 6200 kw) powerful and versatile Progress and tradition: The latest monarch burner The

More information

product Digital dual fuel burners Weishaupt dual fuel burners WGL30-C and WGL40-A ( kw) Information on compact burners

product Digital dual fuel burners Weishaupt dual fuel burners WGL30-C and WGL40-A ( kw) Information on compact burners product Information on compact burners Digital dual fuel burners Weishaupt dual fuel burners WGL30-C and WGL40-A (70 550 kw) Hot for quality Ultra-modern research and production methods, rigorous quality

More information

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw

TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO 40 GS/M SERIES GS 10/M 22/ kw GS 20/M 43/ kw TWO STAGE PROGRESSIVE AND MODULATING GAS BURNERS RIELLO GS/M SERIES GS /M / 5 3/8 19 The Riello GS/M series of two stage progressive or modulating gas burners, is a complete range of products developed

More information

info The intelligent control concept W-FM 100 and W-FM 200 combustion managers Information on digital combustion management

info The intelligent control concept W-FM 100 and W-FM 200 combustion managers Information on digital combustion management info Information on digital combustion management The intelligent control concept W-FM 100 and W-FM 200 combustion managers 2 Digital combustion management Modern gas, oil and dual fuel burners use combustion

More information

product WM 20 for gas, oil, and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on gas, oil, and dual-fuel burners

product WM 20 for gas, oil, and dual-fuel WM 20 monarch burners ( kw) compact and powerful Information on gas, oil, and dual-fuel burners product Information on gas, oil, and dual-fuel burners WM 20 for gas, oil, and dual-fuel WM 20 monarch burners (150 2600 kw) compact and powerful Progress and tradition: The latest monarch burner The monarch

More information

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES The PRESS G series of burners covers a firing range from 107 to 1660 kw and they have been designed for use in civil installations of average dimensions, like building areas and large apartment groups

More information

info Increased capacity for industrial applications Weishaupt monarch gas burner WM-G10 version ZMI ( kw) Information on industrial burners

info Increased capacity for industrial applications Weishaupt monarch gas burner WM-G10 version ZMI ( kw) Information on industrial burners info Information on industrial burners Increased capacity for industrial applications Weishaupt monarch gas burner WM-G10 version ZMI (20 1250 kw) Weishaupt monarch burner WM-G10 ZMI Larger capacity in

More information

ONE STAGE GAS BURNERS RDBS SERIES

ONE STAGE GAS BURNERS RDBS SERIES ONE STAGE GAS BURNERS RDBS SERIES 16 47 kw RDBS.1 16 47 kw The Riello RDBS is a new series of one stage gas burners with integrated gas train, characterised by its small dimensions in spite of its high

More information

info The intelligent control concept W-FM 100 and W-FM 200 combustion managers Product information on digital combustion management

info The intelligent control concept W-FM 100 and W-FM 200 combustion managers Product information on digital combustion management info Product information on digital combustion management The intelligent control concept W-FM 100 and W-FM 200 combustion managers 2 Digital combustion management Modern oil, gas and dual fuel burners

More information

Kerosene - oil burner

Kerosene - oil burner Installation, use and maintenance instructions Kerosene - oil burner Two stage operation CODE MODEL TYPE 3746686 G0D 76T8 90 (0) TECHNICAL FEATURES Thermal power output 44 / 54 0 kw 3.7 / 4.5 0 kg/h Fuel

More information

Oil - kerosene burner

Oil - kerosene burner Installation, use and maintenance instructions Oil - kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 9038 () TECHNICAL FEATURES Thermal power output 8 0 kw.3 5 kg/h Fuel Gas oil 35s,

More information

PRESS P/N - P/N ECO SERIES

PRESS P/N - P/N ECO SERIES The PRESS P/N series of burners covers a firing range from 800 to 5130 kw. They have been designed in three versions for use in commercial and industrial installation, to burn different oil viscosity from

More information

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw

RL/M BLU SERIES. Low NOx Modulating Light Oil Burners FIRING RATES. LOW NOx T. M 190/ kw M 223/ kw LOW NOx T The RL/M BLU burners series covers a firing range from 360 to 1023 kw, and it has been designed for use in hot or superheated water boilers, hot air or steam generators and diathermic oil boilers.

More information

Oil, gas and dual fuel burners. Burner series

Oil, gas and dual fuel burners. Burner series Oil, gas and dual fuel burners Burner series 350...450 Group 4B Capacity 700-5500 kw 1 2 Table of contents General 5 Light fuel oil burners 6 Dimensions and PI diagram 6 Technical data 7 Capacity/back

More information

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53 Installation, use and maintenance instructions Kerosene burners One stage operation CODE MODEL TYPE 3749053 G3BF 490T53 374957 G5BF 49T57 3748953 G5BF 489T53 9036 (6) TECHNICAL FEATURES TYPE - Boiler

More information

Oil, Gas and Dual Fuel Burners

Oil, Gas and Dual Fuel Burners Oil, Gas and Dual Fuel Burners Burner series 130...150 50, 0 Group 3 Capacity 390-3,500 Table of contents General 1 How to choose a burner Light oil burners Technical data and dimensions 3- PI-diagrams

More information

product Digital combustion technology Weishaupt gas burners, WG10 to WG40 ( kw) Information on compact burners

product Digital combustion technology Weishaupt gas burners, WG10 to WG40 ( kw) Information on compact burners product Information on compact burners Digital combustion technology Weishaupt gas burners, WG1 to WG4 (12.5 55 kw) Hot for quality Our motivation is technological progress, which has been driving us for

More information

RS/M SERIES. Modulating Gas Burners FIRING RATES

RS/M SERIES. Modulating Gas Burners FIRING RATES The RS/M burners series covers a firing range from 45 to 2650 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

Doing more for clean environment and energy saving

Doing more for clean environment and energy saving Doing more for clean environment and energy saving Rütli Burners Switzerland AG is a worldwide leading industrial burner solution supplier. Our head quarter is located in Schaffhausen, Switzerland one

More information

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES

RS SERIES. Two Stage Progressive Gas Burners FIRING RATES The RS burners series covers a firing range from 44 to 2290 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Operation

More information

Light oil - kerosene burner

Light oil - kerosene burner Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 3747455 G0KI 474T5 90403 (4) - 0/008 TECHNICAL DATA Thermal power output 95 3 kw 8 8 kg/h

More information

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw

RIELLO 40 F SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL. F kw F kw F kw The Riello 40 F series of one stage light oil burners, is a complete range of products developed to respond to any request for light industrial applications. The Riello 40 F series is available in three

More information

CODE MODEL TYPE PRESS GW 605 T80

CODE MODEL TYPE PRESS GW 605 T80 Installation, use and maintenance instructions Pressure jet burner CODE MODEL TYPE 3473784 PRESS GW 605 T80 291 (2) - 08/2012 Thermal power 107 / 178-350 kw - 92.000 / 153.000-301.000 kcal/h Output 9/15-30

More information

TWO STAGE LIGHT OIL BURNERS PRESS G SERIES

TWO STAGE LIGHT OIL BURNERS PRESS G SERIES TWO STAGE LIGHT OIL BURNERS PRESS G SERIES 7/178 356 kw PRESS 1G 13/19 534 kw PRESS 2G 214/356 712 kw PRESS 3G 273/534 1168 kw PRESS 4G 415/83 166 kw The PRESS G series of burners covers a firing range

More information

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS

RS/1 SERIES. One Stage Gas Burners RS 34/1 MZ RS 44/1 MZ kw kw GAS The RS/1 series of burners covers a firing range from 70 to 550 kw, and they have been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers.

More information

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL

RDB SERIES. One Stage Light Oil and Kerosene Burners FIRING RATES LIGHT OIL The Riello RDB series of one stage light oil and kerosene burners is available in eleven basic models, with an output ranging from 16,8 to 120 kw, in three different structures. The models are available

More information

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw

TWO STAGE GAS BURNER GULLIVER RSD SERIES RS5D 160/ kw TWO STAGE GAS BURNER GULLIVER RSD SERIES 160/208 345 kw The Riello Gulliver is a new model of the series of two stage gas burners, characterized for its small dimensions in spite of its high combustion

More information

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw.

GULLIVER BSD SERIES. Low NOx Two Stage Gas Burners FIRING RATES. BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw. The Riello Gulliver BSD series of two stage gas burners, is a complete range of Low NOx emission products, developed to respond to any request for home heating, conforming to the most severe standards

More information

RES G MRBLU SERIES. Low NOx One Stage Light Oil Burners FIRING RATES. LOW NOx LIGHT OIL

RES G MRBLU SERIES. Low NOx One Stage Light Oil Burners FIRING RATES. LOW NOx LIGHT OIL Low NOx One Stage Light Oil Burners RES G MRBLU SERIES LOW NOx LIGHT OIL RES (Riello Environment Solution) is the new Low NOx light oil burners series with extremely low emissions to meet the increasingly

More information

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES The RS/E-EV MZ burners series covers a firing range from 44 to 2650 kw, and it is based on a new Digital Burner Management System, Riello REC27, which is able to manage the air-fuel ratio by independent

More information

DB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00

DB Series. Technical Data Leaflet. Industrial Dual Block Oil, Gas and Dual Fuel Burners. Industrial TS0086UK00 Technical Data Leaflet Industrial TS0086UK00 DB Series Industrial Dual Block Oil, Gas and Dual Fuel Burners DB 4 1000/2500 5000 kw DB 6 1400/4000 7800 kw DB 9 1500/5000 9500 kw DB 12 1700/7000 12500 kw

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 04-01/04/2008

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 04-01/04/2008 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO R8215222-04EN - Edition 04-01/04/2008 Domestic Gas Boilers ACO 537060 ACO 27 MFFI MET...... 537061 ACO 27 MFFI GPL...... 537062 ACO 27 RFFI SYSTEM MET......

More information

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw.

GULLIVER BS SERIES. Low NOx One Stage Gas Burners FIRING RATES. BS kw BS kw BS kw BS kw. The Riello Gulliver BS series of one stage gas burners, is a complete range of Low NOx emission products, developed to respond to any request for home heating, conforming to the most severe standards regarding

More information

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS

FD68 BURNERS SELECTION GUIDE & ENGINEERING SPECS SELECTION GUIDE The following data can be used to fill in the information appropriate for the burner size required: FD68 C A 150 L M BD FORCED DRAFT MODEL 68 FUEL A-OIL ONLY G-GAS ONLY C-GAS/OIL TYPE OF

More information

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility -.9- KINEDIZER LE High capacity low NOx gas burners Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility Lower NOx and less excess air than standard KINEDIZER

More information

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw

LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES BS1D 16/19 52 kw BS2D 35/40 91 kw BS3D 65/ kw BS4D 110/ kw LOW NOx TWO STAGE GAS BURNERS GULLIVER BSD SERIES 1/19 5 kw 35/4 91 kw 5/75 19 kw 11/14 4 kw The Riello Gulliver BSD series of two stage gas burners, is a complete range of Low NOx emission products, developed

More information

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 Uncontrolled Emissions DM, DMG Technical Data

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 06-01/12/2010

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO. R EN - Edition 06-01/12/2010 SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model ACO R8215222-06EN - Edition 06-01/12/2010 Domestic Gas Boilers ACO 537060 ACO 27 MFFI MET...... 537061 ACO 27 MFFI GPL...... 537062 ACO 27 RFFI SYSTEM MET......

More information

D SERIES TECHNICAL DATA INFORMATION PACKET

D SERIES TECHNICAL DATA INFORMATION PACKET D SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents D Series Uncontrolled Emissions DG, DL, DLG Technical Data Sheet...3 Ratings Table...4 Dimension Table...5 D Series Uncontrolled Emissions DM,

More information

D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR

D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Industrial Combustion offers complete boiler

More information

info WK-series industrial burners Industrial burners WK40 to WK kw to 32,000 kw Information on Duoblock burners

info WK-series industrial burners Industrial burners WK40 to WK kw to 32,000 kw Information on Duoblock burners info Information on Duoblock burners WK-series industrial burners Industrial burners WK40 to WK80 00 kw to 2,000 kw The powerful industrial burner with a modular construction arallel operation Air preheater

More information

TEAMTEC INCINERATORS Market leaders since More than units sold worldwide

TEAMTEC INCINERATORS Market leaders since More than units sold worldwide TEAMTEC INCINERATORS Market leaders since 1972 - More than 11 000 units sold worldwide OG120C. Capacity: 190.000 kcal/h (220 kw). TEAMTEC Incinerator model OG120C The smallest incinerator in our range.

More information

VTZ variable speed Reciprocating compressors

VTZ variable speed Reciprocating compressors MAKING MODERN LIVING POSSIBLE Application guidelines VTZ variable speed Reciprocating compressors R404A, R507, R407C, R134a www.danfoss.com CONTENT VARIABLE SPEED COMPRESSORS... 4 Speed control...4 Advantages

More information

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw

ONE STAGE GAS BURNER GULLIVER RSF SERIES RS5F kw ONE STAGE GAS BURNER GULLIVER RSF SERIES 160 330 kw The Riello Gulliver, is a new model of the series of one stage gas burners, developed to respond to any request for light industrial processes like bakery

More information

RAYPAK ILLUSTRATED PARTS LIST

RAYPAK ILLUSTRATED PARTS LIST RAYPAK ILLUSTRATED PARTS LIST The parts listed are for standard equipment for this model type. Raypak reserves the right to substitute, delete or change any part without notification. The addition of options

More information

Installation- and maintenance instruction ST120 S75/21

Installation- and maintenance instruction ST120 S75/21 Installation- and maintenance instruction ST120 S75/21 1 171 615 30 05-01 178 058 15 DESCRIPTION Components 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly

More information

Heating and Gas Installations - December 2014

Heating and Gas Installations - December 2014 This is an example of good practice maintenance specifications. It is not exhaustive and should only be used to assist with facilities management or specification of a maintenance contract. Emergency Gas

More information

Installation- and maintenance instruction BENTOFLEX ST120KAV

Installation- and maintenance instruction BENTOFLEX ST120KAV Installation- and maintenance instruction BENTOFLEX ST120KAV 1 171 625 61 05-01 178 001 16 DESCRIPTION COMPONENTS 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly

More information

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw

RIELLO 40 GS SERIES. One Stage Gas Burners FIRING RATES. S kw S kw S kw S kw The Riello 40 GS series of one stage gas burners, is a complete range of products developed to respond to any request for home heating. The Riello 40 GS series is available in four different models, with

More information

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS

RIELLO 40 FS SERIES. One Stage Gas Burners FIRING RATES. FS kw FS kw FS kw FS kw FS kw FS kw GAS The Riello 40 FS series of one stage gas burners, is a complete range of products developed to respond to any request for light industrial application. The Riello 40 FS series is available in five different

More information

ONE STAGE GAS BURNERS RS/1 SERIES RS 28/ kw RS 34/1 MZ kw RS 38/ kw RS 44/1 MZ kw

ONE STAGE GAS BURNERS RS/1 SERIES RS 28/ kw RS 34/1 MZ kw RS 38/ kw RS 44/1 MZ kw ONE STAGE GAS BURNERS RS/1 SERIES RS 28/1 163 349 kw RS 34/1 MZ 7 39 kw RS 38/1 232 465 kw RS 44/1 MZ 55 kw The RS/1 series of burners covers a firing range from 7 to 55 kw, and they have been designed

More information

Section 3 Technical Information

Section 3 Technical Information Section 3 Technical Information In this Module: Engine identification Modes of operation Battery charging and heat manage operation Service and repair procedures Maintenance requirements Engine Identification

More information

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

X4 Installation and Operation Manual - POWER FLAME INCORPORATED 7.13.2 Set the burner s combustion air inlet damper to the approximate setting as shown in this manual for the desired firing rate. Also, verify that the correct main orifice is installed in the main orifice

More information

Spare parts catalogue GB 07/2008. Wall-hung boilers ecotec VU 466/4-5 VU 656/4-5

Spare parts catalogue GB 07/2008. Wall-hung boilers ecotec VU 466/4-5 VU 656/4-5 Spare parts catalogue 0020067960.02 GB 07/2008 Wall-hung boilers ecotec VU 466/4-5 VU 656/4-5 Content General view of sheet VU 466/4-5 Page 3 04 Burner Page 4 06 Heat exchanger Page 6 07 Casing parts

More information

Installation- and maintenance instruction B20K-2

Installation- and maintenance instruction B20K-2 Installation- and maintenance instruction B20K-2 1 171 615 51 05-01 178 017 09 DESCRIPTION COMPONENTS 1. Damper motor 2. Air damper 3. Photocell 4. Scale, nozzle assembly 5. Test nipple 6. Nozzle assembly

More information

VICTRIX PRO Wall-hung modular condensing boiler for heating only

VICTRIX PRO Wall-hung modular condensing boiler for heating only PRO Wall-hung modular condensing boiler for heating only Wide range (5 models) High efficiency and low pollutant emissions thanks to condensing technology Modulating heat output from 10 to 100% Possible

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL HP COMBINATION GAS/OIL BURNERS THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone 316-421-0480, Fax 316-421-0948

More information

Installation- and maintenance instruction B80-2/3

Installation- and maintenance instruction B80-2/3 Installation- and maintenance instruction B80-2/3 1 171 625 22 05-01 178 002 64 DESCRIPTION COMPONENTS 1. Flame cone 2. Shrouded disc 3. Nozzle 4. Nozzle assembly 5. Ignition electrodes 6. Ignition cable

More information

Installation- and maintenance instruction BENTOFLEX ST 108 PL

Installation- and maintenance instruction BENTOFLEX ST 108 PL Installation- and maintenance instruction BENTOFLEX ST 108 PL 1 171 625 30 03-01 178 001 13 DESCRIPTION COMPONENTS 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly

More information

RS Series Two Stage Progressive Gas Burners

RS Series Two Stage Progressive Gas Burners Technical Data Leaflet Gas TS0046UK06 RS Series Two Stage Progressive Gas s RS 34 MZ 70/130 390 kw RS 44 MZ 101/203 550 kw RS 50 116/290 580 kw RS 64 MZ 150/400 850 kw RS 70 192/465 814 kw RS 100 232/698

More information

M SERIES TECHNICAL DATA INFORMATION PACKET

M SERIES TECHNICAL DATA INFORMATION PACKET M SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions MG, MM#2, MMG#2 Technical Data Sheet... Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions MM, MMG Technical

More information

Installation- and maintenance instruction B45A2.2

Installation- and maintenance instruction B45A2.2 Installation- and maintenance instruction B45A2.2 160 012 85 DESCRIPTION Components 1. Flame cone 2. Fan housing 3. Fan wheel 4. Damper motor 5. Motor 6. Pump 7. Shrouded disc 8. Nozzle 9. Ignition transformer

More information

No one comes close to matching the 20:1 and 15:1 turndown of our condensing Benchmark boilers.

No one comes close to matching the 20:1 and 15:1 turndown of our condensing Benchmark boilers. Seasonal Efficiency Reliability Longevity Fast ROI Part-Load Efficiency 2.0 and 3.0 boilers. No one comes close to matching the 20:1 and 15:1 turndown of our condensing Benchmark boilers. Seasonal Efficiency

More information

Installation- and maintenance instruction B20KAV/KV

Installation- and maintenance instruction B20KAV/KV Installation- and maintenance instruction B20KAV/KV 1 171 615 33 05-01 178 035 08 DESCRIPTION COMPONENTS 1. Air intake 2. Scale, nozzle assembly 3. Nozzle assembly adjustment 4. Test nipple 5. Ignition

More information

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence The Universal TM gas LowNOx series water heaters contain an electronic spark ignition system. The heater is connected to a 120VAC power source required by the transformer. The transformer steps down the

More information

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER

GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS. GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER TECHNICAL MANUAL GREENOx BT LOW RETURN TEMPERATURE DUAL BT WITH TILED BOILERS GREENOx BT COND LOW RETURN TEMPERATURE WITH CONDENSER GREENOx/GREENOx.e/K WITH THREE GAS PASSES DUAL GRX/DUAL GRX.e THREE GAS

More information

Installation- and maintenance instruction BENTOFLEX ST133KA/K

Installation- and maintenance instruction BENTOFLEX ST133KA/K Installation- and maintenance instruction BENTOFLEX ST133KA/K 178 007 17 DESCRIPTION Components 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly 6. Nozzle 7.

More information

PROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements.

PROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements. PROFIRE D Series burners 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements. Integration starts with the burner. Only Cleaver-Brooks offers complete boiler

More information

Audi A4 Current Flow Diagram No. 44 / 1 Edition

Audi A4 Current Flow Diagram No. 44 / 1 Edition Page 1 of 16 Audi A4 Current Flow Diagram No. 44 / 1 Edition 05.2003 1.8 l - Fuel injection engine (110 kw - Motronic - 4 cylinder), engine code AVJ from model year 2002 1.8 l - Fuel injection engine (120

More information

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve NEOTHERM Hydronic Boiler NTH Hydronic Boiler Date: Indoor Sizes 285-850 Submittal Data Project #: Engineer: Project Name: Prepared By: Location: Bid Date: Contractor: Standard Equipment Large LCD display

More information

Installation- and maintenance instruction B20KA/K

Installation- and maintenance instruction B20KA/K Installation- and maintenance instruction B20KA/K 1 171 615 27 05-01 178 091 07 DESCRIPTION COMPONENTS 1. Air intake 2. Scale, nozzle assembly 3. Nozzle assembly adjustment 4. Test nipple 5. Ignition cables

More information

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps Overview: Sigma/ 3 (S3Cb) The Sigma/3 motor diaphragm are produced with a high-strength metal inner housing for parts subject to load as well as an additional plastic housing to protect against corrosion.

More information

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH TGDFC-6 DFC Direct Fired Gas Heating System Technical Guide for: Outdoor Mounted Units To 0,000 CFM And 14M BTUH Applied Air Keeps You Warm Featuring the Patented AdaptAire controlled Circulation System

More information

Q35 Series Automatic Vent Damper System

Q35 Series Automatic Vent Damper System Installation Sheets Manual 121 Energy Conservation and Miscellaneous Kits Section Q Technical Bulletin Q35 Issue Date 0999 Q35 Series Automatic Vent Damper System Figure 1: Q35 Automatic Vent Damper System

More information

S1 SERIES TECHNICAL DATA INFORMATION PACKET

S1 SERIES TECHNICAL DATA INFORMATION PACKET S1 SERIES TECHNICAL DATA INFORMATION PACKET Table of Contents Uncontrolled Emissions S1G, S1L, S1LG Technical Data Sheet...3 Ratings Table...4 Dimensions Table...5 Uncontrolled Emissions S1E, S1EG Technical

More information

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) EE771/EE772 Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) The inline flow meter EE771/EE772, based on the measurement principle of thermal mass flow, is ideally suited for the

More information

Gas burner Dual fuel burner. Gas burner. Series RG GG MG. Dual fuel burner. Series MK

Gas burner Dual fuel burner. Gas burner. Series RG GG MG. Dual fuel burner. Series MK Gas burner Dual fuel burner Gas burner Series RG GG MG Dual fuel burner Series MK Series RG Fully automatic gas burner, tested and approved in accordance with DIN EN 676 suitable for the combustion of

More information

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 1 and CTM 2 Liquid Ejector

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 1 and CTM 2 Liquid Ejector Data sheet Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 1 and CTM 2 Liquid Ejector Liquid Ejector is a part of the CO2 Adaptive Liquid Management (CALM), ' solution to handle liquid in

More information

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET PROFIRE V SERIES TEHNIA DATA INFORMATION PAKET Technical Data Uncontrolled Emissions onfiguration (VG, V, VG) 1.3-16.8 MM BTU/H NG; 9.3-120 GPH #2 OI U listed with choice of NFPA, SD-1, GAP, and FM for

More information

Oil, Gas and Dual Fuel Monoblock Burners

Oil, Gas and Dual Fuel Monoblock Burners Capacity Oil, Gas and Dual Fuel Monoblock Burners 1-133 kw 1 Low Emission Combustion Technology Table of contents 2 Oilon Burners 8 Choosing the burner 9 NOx emissions 1 FGR - Flue Gas Recirculation 11

More information

High Pressure Bypass System Type SOV acc. to TRD 421

High Pressure Bypass System Type SOV acc. to TRD 421 High Pressure Bypass System Type SOV acc. to TRD 421 GS valve engineering GmbH Phone: +49-208-833 2090 sales@gs-valve.eu Duisburger Strasse 375 Fax: +49-208-833-2095 www.gs-valve.eu 46049 Oberhausen GERMANY

More information

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS 27 BFFI PLUS Edition 4 Current from Serial No: 2320317800001 to: ------------------ Add to Edition 3 1 71 70 9 8 7 5 9 3 4 3 5 7 5 1 2 1 8 9 120 0

More information

Skotch Trifecta Oil Valve System

Skotch Trifecta Oil Valve System Skotch Trifecta Oil Valve System A compact high-performance valve system for firing and purging oil-fired burners and igniters. Revision 0 Need a reliable, cost-effective solution for firing and purging

More information

available in battery up to 4 units for a total of 560 kw

available in battery up to 4 units for a total of 560 kw MODULATING CONDENSING BOILER with double premix low NOx burner and double heat exchanger EXPANDABLE IN BATTERY for indoor and outdoor installations (IPX5D) OUTPUT RANGE from 10 to 560 kw (in battery) WORKING

More information

Installation- and maintenance instruction B20KA/K

Installation- and maintenance instruction B20KA/K Installation- and maintenance instruction B20KA/K 178 091 07 DISCRIPTION Components 1. Air intake 2. Scale, nozzle assembly 3. Nozzle assembly adjustment 4. Test nipple 5. Ignition cables 6. Schrouded

More information

COMMERCIAL MODELS: XTHERM 1005A THROUGH 2005A

COMMERCIAL MODELS: XTHERM 1005A THROUGH 2005A COMMERCIAL MODELS: XTHERM 1005A THROUGH 2005A CATALOG NO. 9300.90 Effective: 12-13-13 Replaces: NEW RAYPAK ILLUSTRATED PARTS LIST MODEL SIZES: 1005A, 1505A & 2005A MODEL TYPES: MODULATING VERTICAL BOILER

More information

Weishaupt Low NOx Solutions for Boiler Applications

Weishaupt Low NOx Solutions for Boiler Applications Weishaupt Low NOx Solutions for Boiler Applications Presentation by Greg Meyer Ottawa, 2003 Content Weishaupt Company and Products Weishaupt Low NOx Solutions Applications 1 Max Weishaupt GmbH Administration

More information

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM DIESEL SPACE HEATER - SERVICE MANUAL INDEX 1. CONTROLS AND COMPONENTS 2. FLAME CONTROL CYCLES 3. MAINTENANCE SCHEDULE 4. REPAIR PROCEDURES 1. FAN MOTOR ASSEMBLY 2. FUEL FILTER ASSEMBLY 3. FUEL PUMP ASSEMBLY

More information