World Super Series WSS The extensive breaker series from Mitsubishi Electric

Size: px
Start display at page:

Download "World Super Series WSS The extensive breaker series from Mitsubishi Electric"

Transcription

1 MODEL PUSH TO TRIP TEST 3 P IEC JIS C Ue 690VAC 00VAC 440VAC 41VAC 400VAC 380VAC 230VAC T Ir Ip Is Ts EN C Icu/Ics 8/8kA 30/30kA 8/8kA MODEL POLE Ui 690VAC 0-60Hz 8kV Uimp PUSH TO TRIP 3 P T Ir Ip Is TL Ii Ts TEST JIS Ue 0VAC 460VAC 220VAC IEC EN VAC 20VAC Ip(xIr) Icn 3kA 0kA 8kA Icu/Ics 10/10kA 30/30kA 42/42kA 4/4kA 8/8kA 40 C 0kA 8kA Ii(X400A) Ir(A) IS(xIr) MODEL PUSH TO TRIP T Ir Ip Is TL Ii Ts TEST In(A) OVER PAL 70% Ir( 400A) IS( In, Ir) II( 400A) T L(s) T S(s) IP( In, Ir) IEC EN Ue Icu/Ics 690VAC 2/13kA 00VAC 6/33kA 440VAC 8/43kA 400VAC 8/43kA 230VAC 12/63kA Cat. B Icw 20kA 0.1s World Super Series WSS The extensive breaker series from Mitsubishi Electric The circuits of the Mitsubishi Electric breaker series are amongst the smallest compact circuit breakers in the world with electronic overload indication of this kind. The system is based, among other things, on the well-known and proven microprocessor technology. 4 MITSUBISHI NO-FUSE BREAKER POLE Ui690V Cat.A NF20-SEV In 20A Uimp 8kV OFF ON IIIIIII IIIIIII IIIIIII IIIIIII TL Ii Ii(X100A) MITSUBISHI NO-FUSE BREAKER NF400-SEP 400A OFF ON 400 TL(sec) TS(sec) MITSUBISHI ELECTRIC MITSUBISHI NO-FUSE BREAKER NF1000-SS In 1000A Ir A MITSUBISHI ELECTRIC NF20-SEV, 3p NF400-SEW, 3p NF1000-SEW, 3p WSS World Super Series The WSS breaker series meets national and international protection ratings according to VDE, EN, and IEC standards for industrial applications as well as for extended shipping demands. The new tripping technology guarantees a high reliability and highest protection. z16 to 20 A in one model size (3- and 4-pole) zinterchangeable relay unit (thermal type or electronic type) zavailable in fixed and plug-in versions zbreaking capacity zi cs = 100 % I cu, up to 690 V zadditional disconnectors available The proven World Super Series features technical know-how and the micro-processor technology tried and tested in longstanding experience. The fully enclosed circuit breakers provide an increased safety and at the same time decreased switching times. z400 to 800 A z2 model sizes (3- and 4-pole) zelectronic trip system zavailable in fixed and plug-in versions zadditional disconnectors available The proven standard series for a high breaking performance providing an optimum protection for transformer and generator feed in, and output breakers. Circuit breakers can be used as section or disconnecting switch. z1000 to 1600 A z1 model size (3- and 4-pole) zelectronic trip system zavailable in fixed versions zadditional disconnectors available Intelligent breaking technology for your safety ka (ICU at 400 V AC) Breaking performance With its innovative breaking technology all Mitsubishi Electric breakers offer greater safety and even faster circuit-breaking speed through the use of the latest switch-off technology and innovative engineering, with a newly developed electronic trip relay UGV RGV HGV LGV UEW REW HEW SEW The complete range of moulded case circuit breakers from 3 to 1600 A. 10 7, HV SV SV SV/ SGV/ SEV SEW 12/160/20 400/630/ /120/1600 AF 32

2 Outline New breaking technology With its new breaking technology the circuit breakers offer greater safety and even faster circuit-breaking speed through the use of the latest switch-off technology and innovative engineering, with a newly developed electronic trip relay. Arc-extinguishing device Mitsubishi Electric MCCBs feature excellent arc-extinguishing performance by virtue of the optimum combination of grid gap, shape, and material. Rapid movement Switching mechanism The contacts open and close rapidly, regardless of the moving speed of the handle, minimizing contact wear and ensuring safety. 4 Magnetic force Magnetic flux Grid Arc Moulded case (cover) Handle ztrip indication Arc extinction The automatically tripped condition is indicated by the handle in the center position between ON and OFF; the yellow or white line cannot be seen in this position. Arc runner The arc is instantaneously transferred to the arc-extinguishing chamber (see the figure above) by the arc runner, which reduces damage to contacts and improves interrupting performance. Trip button (push to trip) Enables tripping mechanically from outside, for confirming the operation of the accessory switches and the manual resetting function. MITSUBISHI NO-FUSE BREAKER MODEL POLE Ui690V Cat.A NF20-SEV In 20A 3 P Uimp 8kV PUSH TO TRIP TEST OFF ON IEC EN JIS C C Ue Icu/Ics 690VAC 8/8kA 00VAC 30/30kA 440VAC 41VAC 400VAC 380VAC 230VAC 8/8kA IIIIIII IIIIIII IIIIIII IIIIIII T Ir Ip Is TL Ii Ts Ii(X100A) The figure shows the handle in tripped position. zresetting Resetting after tripping is performed by first moving the handle OFF position to engage the mechanism, then returning the handle to ON to reclose the circuit. ztrip-free Even if the handle is held at ON, the breaker will trip if an overcurrent flows. zcontact on Mechanism Even in the worst case in which welding occurs owing to an overcurrent, the breaker will trip and the handle will maintain to ON, indicating the energizing state. Type NF20-SEV construction thermal trip current value The setting can be changed by simply turning the control dials, providing the optimum characteristics for particular road conditions. 33

3 A microcomputer and Mitsubishi Electric s original IC fulfill a new high level of safety Safer and more reliable power Electronic device loads, such as inverters, distort the current waveform. Mitsubishi Electric s electronic breakers use a digital detector to measure the current s effective value and minimize overload tripping errors. This enables precise protection of the circuit. Alarm function monitors and anticipates interruptions Our electronic moulded-case circuit breakers feature a pre-alarm system as standard. The pre-alarm outputs an alarm before the circuit breaker trip is activated. When the load current exceeds the set pre-alarm current, it outputs a pre-alarm signal (from a solid-state relay) and lights the LED. The pre-alarm module (with contact output) is optional available with electronic molded-case and earth-leakage circuit breakers (on request). 4 Improved protection against fluctuations in the load current Our standard electronic trip relay offers a number of outstanding benefits. The user has a choice of six different parameters as tripping characteristics with the multiple coordinated protection method. Better protection can be obtained between the high-voltage fuse, OCR and the low voltage fuse. Time [s] Pre-alarm current I P Current setting I r Load current High-voltage fuse allowable short-time characteristic Long time-delay operating time T L Short time-delay tripping current I S Short time-delay operating time T S Instantaneous tripping current I I High voltage Low voltage MCCB Load Current [A] Coordinated protection from multiple tripping characteristics Rated current I n Current setting I r Short time-delay operating time T Sd TEST In(A) IS( In, Ir) Ir( 400A) II( 400A) T L(s) T S(s) IP( In, Ir) Instantaneous tripping current II Instantaneous tripping current II NF400-SEW 3P Long time-delay operating time T L Short time-delay operating time T Sd Portable tester facilitates checking and maintenance The separately sold portable tester allows the user to check the four characteristics: 1. Long-delay tripping 2. Short-delay tripping 3. Instantaneous tripping 4. Pre-alarm characteristics LEDs for load current, pre-alarm and over-current show the operating status. Overload protection and safety The neutral-pole overload protection circuit is standard with 4-wire electronic moulded-case devices. It prevents burn-out when the neutral- pole s load current is greater than the voltage pole in a 3-phase 4 wire circuit which is prone to distorted third-harmonic current flows. L1 L2 L3 N 34

4 Calculation and selection software MELSHORT2 MELSHORT2 The new calculation software for low voltage switchgears MELSHORT2 is a software package that provides all the functions needed for planning and dimensioning switchgear systems. Increasingly demanding technical specifications and accountability regulations are making switchgear configuration much more critical than it used to be. In the past, software for calculating and dimensioning switchgear was helpful nowadays it s absolutely essential. It supports all modern international electrical engineering standards and shines with simple and reliable operation. Circuit diagram of the network to be calculated, with input field The program calculates the short-circuit levels and currents at all necessary points for all switchgear components, including the power supply transformer and circuit breakers, the emergency generators, the individual motor and capacitor group branch circuits and all the other power distribution circuits, down to the last circuit breaker. This makes it possible to select the ideal breaker for every task, for optimum performance and cost-efficiency. MELSHORT2 has a comprehensive range of powerful, easy-to-use functions, including: zselective shutdown zbackup protection zcoordination with the main power supply systems zallowance for the start-up currents of electric motors These functions make it possible to optimise the configuration of your switchgear equipment for the specific requirements of your applications. 4 The calculated results, the hardware model suggestions and the wiring diagram with all the relevant values can be processed and used as documentation for the switchgear installation. Another welcome extra is the free Internet update service. Display of the trip curves of a circuit breaker in the network Specifications Operating system Disk type MELSHORT2 MS Windows 9/98/NT4.0/2000 CD-ROM Order information

5 T K3 K2 K1 K3 SW1 K3 K1 Uc K2 K2 S2 S1 P2 P1 AUTO MANU K1 R E S T E T PUSH TO TRIP POWER SUPPLY MODULE CONTROLL CIRCUIT VOLTAGE Power Supply (TRIP) P S4 S2 P S1 O P1 P2 OFF ON MODEL Ui 690V Cat.A IEC JIS C Ue 690VAC 2VAC 00VAC 440VAC 380/41VAC 230VAC F RATED CURRENT F Operating Circuit Uc 20 A R MODEL SERIAL: 0/60Hz Uimp 8kV EN C Icu/Ics 8/8kA 22/22kA 30/30kA 8/8kA MITSUBISHI ELECTRIC E S4 S E T PUSH TO TRIP ON O MSDBA-NF2GSW A0106 F (MANU) F Discharge 12V A AC 20V 3A DC 12V 0.4A DC 20V 0.2A 12V A AC 20V 3A DC 12V 0.4A DC 20V 0.2A 9 c Install and uninstall the accessory in tripped position, not in ON or OFF position UVTSA20-2GSWRS AC V 0/60Hz Install and uninstall the accessory in tripped position, not in ON or OFF position SHTA240-2GSWRS D3 D1 P1 Ip C2 S2 Ir Is TL Ii Ts Ii(X100A) Product skeleton of accessories Mitsubishi Electric offers a wide range of accessories for the Moulded-case circuit breakers and Disconnectors to serve almost all variations of applications. Detailled information on request Circuit Breaker see page 38 2 Solderless (Box) terminals see page 61 3 Rear connection studs see page Insulating barriers (BA-F) see page 68 4 Small terminal covers (TC-S) see page 67 6 Large terminal covers (TC-L) see page 67 7 Rear terminal covers (BTC) see page 67 8 Plug-in base (PM) see page 61 9 Connections for Plug-in see page Mechanical interlock (MI) see page OFF Lock with 3 padlocks (HL) see page ALARM SWITCH AC AUXILIARY SWITCH AC 98 ALc 96 ALb 98 ALa 14 AXa 12 AXb 11 AXc 11c 12b 14a 98a 96b AX AL ALAX-2GSWLS MITSUBISHI ELECTRIC Handle lock device (LC, HLF, HLN, HLS) see page Variable-depth operating handle, V type see page Rotary operating handle, R type see page 63 1 Electrical operating device (MDS) see page Alarm and Auxiliary switches (AL, AX) see page 4 17 Under voltage trip device (UVT) see page 8 18 Shunt trip device (SHT) see page 6 R I E D TEST T ON R I P P E D SOURCE Hi Lo P3 D2 P C1 S1 SHT Control circuit voltage should be supplied to P1 and P2 terminals. P1 P2 S1 S2 S4 MITSUBISHI MODEL MDSPSA240-SW AC V/DC100-20V Push to ON Push to OPEN NO-FUSE BREAKER NF20-SGW ON Pull Push 36

6 MODEL POLE Ui690V Cat.A PUSH TO TRIP 3 P Uimp 8kV TEST IEC JIS C Ue 690VAC 00VAC 440VAC 41VAC 400VAC 380VAC 230VAC T Ir Ip Is TL Ii Ts Ii(X100A) EN C Icu/Ics 8/8kA 30/30kA 8/8kA MITSUBISHI NO-FUSE BREAKER NF20-SEV In 20A OFF ON IIIIIII IIIIIII IIIIIII IIIIIII

7 Model overview and specifications 4 S series L series H series R series U series Disconnectors Type/Series WS-V series NF32-SV NF63-SV NF12-SV NF12-SGV NF12-SEV NF160-SGV Rated current In max. [A] * 12* 160* Rated insulation voltage Ui [V] AC Number of poles 3 3/4 3/4 3/4 3/4 3/4 Rated breaking capacity [ka] (Icu/Ics) IEC EN VDE 0660 AC a (0/60 Hz) 690 V 8/8 8/8 8/8 8/8 00 V 2./2. 7./7. 18/18 30/30 30/30 30/ V 2./2. 7./7. 2/2 36/36 36/36 36/ V / 7./7. 30/30 36/36 36/36 36/ V 7./7. 1/1 30/30 8/8 8/8 8/8 Dimensions WxHxD [mm] 7x130x68 7/100x130x68 90/120/x130x68 10/140x16x68 10/140x16x68 10/140x16x68 Type NF12-LGV NF160-LGV Rated current In max. [A] 12* 160* Rated insulation voltage Ui [V] AC Number of poles 3/4 3/4 Rated breaking capacity [ka] (Icu/Ics) IEC EN VDE 0660 AC a (0/60 Hz) 690 V 8/8 8/8 00 V 36/36 36/ V 0/0 0/0 400 V 0/0 0/0 230 V 90/90 90/90 Dimensions WxHxD [mm] 10/140x16x68 10/140x16x68 Type NF63-HV NF12-HGV NF12-HEV NF160-HGV Rated current In max. [A] 63 12* 12* 160* Rated insulation voltage Ui [V] AC Number of poles 3/4 3/4 3/4 3/4 Rated breaking capacity [ka] (Icu/Ics) IEC EN VDE 0660 AC a (0/60 Hz) 690 V 2./2. 10/8 10/8 10/8 00 V 7./7. 0/38 0/38 0/ V 10/8 6/6 6/6 6/6 400 V 10/8 7/7 7/7 7/7 230 V 2/19 100/ / /100 Dimensions WxHxD [mm] 7/100x130x68 10/140x16x68 10/140x16x68 10/140x16x68 Type NF12-RGV Rated current In max. [A] 12* Rated insulation voltage Ui [V] AC 690 Number of poles 3 Rated breaking capacity [ka] (Icu/Ics) IEC EN VDE 0660 AC a (0/60 Hz) 690 V 00 V 440 V 12/ V 10/ V 10/10 Dimensions WxHxD [mm] 10x16x68 Type NF12-UV Rated current In max. [A] 12 Rated insulation voltage Ui [V] AC 690 Number of poles 3/4 Rated breaking capacity [ka] (Icu/Ics) IEC EN VDE 0660 AC a (0/60 Hz) 690 V 10/10 00 V 200/ V 200/ V 200/ V 200/200 Dimensions WxHxD [mm] 10/140x240x68 Type DSN32-SV DSN63-SV DSN12-SGV DSN160-SGV Rated current In max. [A] Rated insulation voltage Ui [V] AC/DC Rated voltage Ue [V] AC (0/60 Hz)/DC 00/20 00/20 690/ /300 Number of poles 3 3/4 3/4 3/4 Max. switching current [A] (breaking) AC/DC 26/128 04/ / /640 Dimensions WxHxD [mm] 7x130x68 7/120x130x68 10/140x16x68 10/140x16x68 a DC on request b In case of solderless terminal, interrupting capacity reduces. * adjustable 38

8 WS-V series WSS series NF20-SV NF20-SGV NF20-SEV NF400-SEW NF630-SEW NF800-SEW NF1000-SEW NF120-SEW NF1600-SEW 20 20* 20* 400* 630* 800* 1000* 120* 1600* /4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 8/8 8/8 8/8 10/10 b 10/10 10/10 2/13 2/13 2/13 30/30 30/30 30/30 30/30 b 30/30 30/30 6/33 6/33 6/33 36/36 36/36 36/36 42/42 b 42/42 42/42 8/43 8/43 8/43 36/36 36/36 36/36 0/0 b 0/0 0/0 8/43 8/43 8/43 8/8 8/8 8/8 8/8 b 8/8 8/8 12/63 12/63 12/63 10/140x16x68 10/140x16x68 10/140x16x68 140/18x27x /18x27x /280x27x /280x406x /280x406x /280x406x140 NF20-LGV 20* 690 3/4 8/8 36/36 0/0 0/0 90/90 10/140x16x68 NF20-HGV NF20-HEV NF400-HEW NF630-HEW NF800-HEW 20* 20* 400* 630* 800* /4 3/4 3/4 3/4 3/4 10/8 10/8 10/10 1/1 1/1 0/0 0/0 0/0 0/0 0/0 6/6 6/6 6/6 6/6 6/6 7/7 7/7 70/70 70/70 70/70 100/ / / / /100 10/140x16x68 10/140x16x68 140/18x27x /18x27x /280x27x103 NF20-RGV NF400-REW NF630-REW NF800-REW 20* 400* 630* 800* /10 20/1 20/1 70/3 70/3 70/3 12/12 12/63 12/63 12/63 10/10 12/63 12/63 12/63 10/10 10/7 10/7 10/7 10x16x68 140x27x x27x x27x103 NF20-UV NF400-UEW NF800-UEW * 800* /4 3/4 3/4 1/1 3/3 3/3 200/ / / / / / / / / / / /200 10/140x240x68 140/280x297/322x /280x322x200 DSN20-SGV DSN400-SW DSN630-SW DSN800-SW DSN1000-SW DSN120-SW DSN1600-SW / /20 690/20 690/20 660/20 660/20 660/20 3/4 3/4 3/4 3/4 3/4 3/4 3/4 2000/ / / / / / / /140x16x68 140/18x27x /18x27x /280x27x /280x406x /280x406x /280x406x140 4 * adjustable 39

9 Specifications of moulded-case circuit breakers 3 12 A Type NF32-SV NF63-SV NF63-HV NF12-SV NF12-SGV Frame (A) Rated data Mechanical data External accessories Others Rated current In [A] at ambient temperature 40 C 3, 4, 6, 10, 16, 20, 2, 32 Fixed 3, 4, 6, 10, 16, 20, 2, 32, 40, 0, 63 Fixed 10, 16, 20, 2, 32, 40, 0, 63 Fixed 7,80,100,12 Fixed Number of poles 3 3/4 3/4 3/4 3/4 Rated insulation voltage Ui [V] AC V 2./2. 8/8 8/8 Rated 00 V 2./2. 7./7. 7./7. 18/18 30/30 breaking AC capacity [ka] IEC/EN (0/60 Hz) 440 V 2./2. 7./7. 10/8 2/2 36/ V / 7./7. 10/8 30/30 36/36 (Icu/Ics) 230 V 7./7. 1/1 2/19 30/30 8/8 DC 20 V 2./2. 7./7. 7./7. d 20/20 d 20/20 d Utilization category A A A A A Rated impulse withstand voltage Uimp [kv] Pollution degree Reverse connection V Suitable for isolation V ca a 7 7/100 7/100 90/120 10/140 Dimensions [mm] a c b b c ca Weight [kg] /1,0 0.7/1,0 1/ /2.0 Cassettetype accessories Accessories connection Installation and connection Built-in accessories External operating handle Alarm switch (AL) V Auxiliary switch (AX) V Shunt trip (SHT) V Undervoltage closing Non-synchronous (UVT-N) trip Synchronous closing (UVT-S) V with terminal block (SLT) V with internal terminal type V Screw terminal (standard) V Front Solderless terminal V Busbar terminal Rear (B) V Rear (PM) Plug-in Rear front IP 20 with auto trip (PM-IP) V Pre-alarm-contact output a (PAL) Overcurrent trip alarm a (OAL) Door mounting (V) V Mounted on breaker (R) V Electrical operation device (MDS) V Handle lock for use (HL) V Handle lock device with padlock (HL-S) V Lock cover (LC) V Terminal cover Large (TC-L) V Small (TC-S) V For rear connection (BTC) V For plug-in (PTC) V 16 20, 20 2, 2 32, 32 40, 3 0, 4 63, 6 80, , Mechanical interlock (MI) V Insulating barrier Between phases (Standard) (BA-F) V Adapter for IEC 3 mm rail V V V/ V CE marking Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration CCC recognition Recognized Recognized Recognized Recognized Recognition in process Automatic tripping device Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Trip button Equipped Equipped Equipped Equipped Equipped a Both PAL and OAL is not available. Only one specified. b Others on request. c On request. d Use of 3- or 4-pole breaker for DC, see wiring diagram on the next page. Missing specifications accord. to IEC/EN on request. 40

10 NF12-SEV NF12-LGV NF12-HGV NF12-HEV NF12-RGV NF12-UV , 32 63, , 20 2, 2 32, 32 40, 3 0, 4 63, 6 80, , , 20 2, 2 32, 32 40, 3 0, 4 63, 6 80, , , 32 63, , 20 2, 2 32, 32 40, 40 0, 0 63, 63 80, , , 20, 30, 40, 0, 60, 7, 100, 12 Fixed 3/4 3/4 3/4 3/4 3 3/ /8 8/8 10/8 10/8 12/12 10/10 30/30 36/36 0/38 0/38 10/10 200/200 36/36 0/0 6/6 6/6 10/10 200/200 36/36 0/0 7/7 7/7 10/10 200/200 8/8 90/90 100/ /100 10/10 200/200 20/20 d 40/40 d A A A A A A /140 10/140 10/140 10/ / / / / / /1.9 V V /V / V Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Recognized Recognition in process Recognition in process Recognized Recognition in process Electronic Thermal-magnetic Thermal-magnetic Electronic Thermal-magnetic Thermal-magnetic Equipped Equipped Equipped Equipped Equipped Equipped Use of 3- and 4-pole breakers for DC Line 3-pole Load Line 4-pole N Load xdfgb 41

11 Specifications of moulded-case circuit breakers A Type NF160-SGV NF160-LGV NF160-HGV NF20-SV NF20-SGV Frame (A) Rated data Mechanical data External accessories Others Rated current In [A] at ambient temperature 40 C , 160, 17, 200, 22, 20 Fixed Number of poles 3/4 3/4 3/4 3/4 3/4 Rated insulation voltage Ui [V] AC V 8/8 8/8 10/8 8/8 8/8 Rated 00 V 30/30 36/36 0/38 30/30 30/30 breaking AC capacity [ka] IEC/EN (0/60 Hz) 440 V 36/36 0/0 6/6 36/36 36/ V 36/36 0/0 7/7 36/36 36/36 (Icu/Ics) 230 V 8/8 90/90 100/100 8/8 8/8 DC 20 V 20/20 d 20/20 d 40/40 d 20/20 d 20/20 d Utilization category A A A A A Rated impulse withstand voltage Uimp [kv] Pollution degree Reverse connection V Suitable for isolation V ca a 10/140 10/140 10/140 90/120 10/140 Dimensions [mm] a c b b c ca Weight [kg] 1.6/ / /2.0 1/ /2.0 Cassettetype accessories Accessories connection Installation and connection Built-in accessories External operating handle Alarm switch (AL) V Auxiliary switch (AX) V Shunt trip (SHT) V Undervoltage closing Non-synchronous (UVT-N) trip Synchronous closing (UVT-S) V with terminal block (SLT) V with internal terminal type V Screw terminal (standard) V Front Solderless terminal V V V V Busbar terminal Rear (B) V Rear (PM) Plug-in Rear front IP 20 with auto trip (PM-IP) V Pre-alarm-contact output a (PAL) Overcurrent trip alarm a (OAL) Door mounting (V) V Mounted on breaker (R) V V V V Electrical operation device (MDS) V V V V Handle lock for use (HL) V Handle lock device with padlock (HL-S) V Lock cover (LC) V Terminal cover Large (TC-L) V Small (TC-S) V For rear connection (BTC) V For plug-in (PTC) V , , Mechanical interlock (MI) V Insulating barrier Between phases (Standard) (BA-F) V Adapter for IEC 3 mm rail V CE marking Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration CCC recognition Recognition in process Recognition in process Recognition in process Recognized Recognition in process Automatic tripping device Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Trip button Equipped Equipped Equipped Equipped Equipped a Both PAL and OAL is not available. Only one specified. b Others on request. c On request. d Use of 3- or 4-pole breaker for DC, see wiring diagram on the next page. Missing specifications accord. to IEC/EN on request. 42

12 NF20-SEV NF20-LGV NF20-HGV NF20-HEV NF-20-RGV NF20-UV , , , , , , , , , 10, 17, 200, 22, 20 Fixed 3/4 3/4 3/4 3/4 3 3/ /8 8/8 10/8 10/8 1/1 30/30 36/36 0/38 0/38 200/200 36/36 0/0 6/6 6/6 12/12 200/200 36/36 0/0 7/7 7/7 10 /10 200/200 8/8 90/90 100/ /100 10/10 200/200 20/20 d 40/40 d A A A A A A /140 10/140 10/140 10/ / / / / / /3.7 / V V V Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Self-declaration Recognized Recognition in process Recognition in process Recognized Recognition in process Electronic Thermal-magnetic Thermal-magnetic Electronic Thermal-magnetic Thermal-magnetic Equipped Equipped Equipped Equipped Equipped Equipped Use of 3- and 4-pole breakers for DC 3-pole 4-pole Line Load Line N Load 43

13 Specifications of moulded-case circuit breakers A Type NF400-SEW NF400-HEW NF400-REW Frame (A) Rated current In [A] at ambient temperature 40 C Number of poles 3/4 3/4 3 Rated insulation voltage Ui [V] AC Rated data Mechanical data External accessories Others Rated breaking capacity [ka] (Icu/Ics) IEC/EN AC a (0/60 Hz) 690 V 10/10 (/) b 10/10 1/10 00 V 30/30 (2/2) b 0/0 70/3 440 V 42/42 (36/36) b 6/6 12/ V 0/0 (36/36) b 70/70 12/ V 8/8 (6/6) b 100/100 10/7 Utilization category B B B Rated short-time withstand current Icw [ka/s] /0.2 /0.2 /0.2 Rated impulse withstand voltage Uimp [kv] Pollution degree Reverse connection V V V Suitable for isolation V V V ca a 140/18 140/ Dimensions [mm] a c b b c ca Weight [kg] 6.0/ / Cassettetype accessories Accessories connection Installation and connection Built-in accessories External operating handle Alarm switch (AL) V V V Auxiliary switch (AX) V V V Shunt trip (SHT) V V V Undervoltage closing Non-synchronous (UVT-N) V V V trip Synchronous closing (UVT-S) V V V with terminal block (SLT) V V V with internal terminal type c V V V Front Busbar terminal (standard) V V V Rear (B) V V V Plug-in Rear (PM) V V V Pre-alarm-contact output (PAL) V V V Trip indicator (TI) V V V Door mounting (V) V V V Mounted on breaker (R) V V V Electrical operation device Spring-charge type (MDS) V V V Handle lock device Handle lock for use (HL) V V V with padlock (HL-S) V V V Terminal Large (TC-L) V V V cover For rear connection (BTC) V V V Mechanical interlock (MI) V V V Insulating barrier Between phases (Standard) (BA-F) V V V Marine approval d for 3 pole breakers LR, GL, BV, DNV, AB LR, GL, BV, AB LR, GL, BV, AB Automatic tripping device Electronic Electronic Electronic Trip button Equipped Equipped Equipped a DC type on request. b In case of solderless terminal, interrupting capacity reduces. c On request. d Others on request. Missing specifications accord. to IEC/EN on request. 44

14 NF400-UEW NF630-SEW NF630-HEW NF630-REW /4 3/4 3/ /3 10/10 3/18 20/1 170/170 30/30 0/0 70/3 200/200 42/42 6/6 12/63 200/200 0/0 70/70 12/63 200/200 8/8 100/100 10/7 B B B B / / / / / /18 140/ / / /8.3 6./ V/ V V V V V V V V V V V V LR, GL, BV, AB LR, GL, BV, AB LR, GL, BV, AB LR, GL, BV, AB Electronic Electronic Electronic Electronic Equipped Equipped Equipped Equipped 4

15 Specifications of moulded-case circuit breakers A Type NF800-SEW NF800-HEW NF800-REW Frame (A) Rated current In [A] at ambient temperature 40 C Number of poles 3/4 3/4 3 Rated insulation voltage Ui [V] AC Rated data Mechanical data External accessories Others Rated breaking capacity [ka] (Icu/Ics) IEC/EN AC a (0/60 Hz) 690 V 10/10 1/1 00 V 30/30 0/0 70/3 440 V 42/42 6/6 12/ V 0/0 70/70 12/ V 8/8 100/100 10/7 Utilization category B B B Rated short-time withstand current Icw [ka/s] 9.6/ / /0.2 Rated impulse withstand voltage Uimp [kv] Pollution degree Reverse connection V V V Suitable for isolation V V V ca a 210/ / Dimensions [mm] a c b b c ca Weight [kg] 10.9/ / Cassettetype accessories Accessories connection Installation and connection Built-in accessories External operating handle Alarm switch (AL) V V V Auxiliary switch (AX) V V V Shunt trip (SHT) V V V Undervoltage closing Non-synchronous (UVT-N) V V V trip Synchronous closing (UVT-S) V V V with terminal block (SLT) V V V with internal terminal type c V V V Front Busbar terminal (standard) V V V Rear (B) V V V Plug-in Rear (PM) V V V Pre-alarm-contact output (PAL) V V V Trip indicator (TI) V V V Door mounting (V) V V V Mounted on breaker (R) V V V Electrical operation device Spring-charge type (MDS) V V V Handle lock device Handle lock for use (HL) V V V with padlock (HL-S) V V V Terminal Large (TC-L) V V V cover For rear connection (BTC) V V V Mechanical interlock (MI) V V V Insulating barrier Between phases (Standard) (BA-F) V V V Marine approval d for 3 pole breakers LR, GL, BV, DNV, AB LR, GL, BV, AB LR, GL, BV, AB Automatic tripping device Electronic Electronic Electronic Trip button Equipped Equipped Equipped a DC type on request. b On request. c Others on request. d Assembly by factory. Missing Specifications accord. to IEC/EN on request. 46

16 NF800-UEW NF1000-SEW NF120-SEW NF1600-SEW /4 3/4 3/4 3/ /3 2/13 2/13 2/13 170/170 6/33 6/33 6/33 200/200 8/43 8/43 8/43 200/200 8/43 8/43 8/43 200/200 12/63 12/63 12/63 B B B B 9.6/0.2 20/0.3 20/0.3 20/ / / / / / / / /41.2 V V V V V V V V V V V V LR, GL, AB LR, GL, AB Electronic Electronic Electronic Electronic Equipped Equipped Equipped Equipped 47

17 Specifications of disconnectors DSN, IEC , EN Type DSN32-SV DSN63-SV DSN12-SGV DSN160-SGV DSN20-SGV Rated current In [A] 40 C Number of poles 3 3/4 3/4 3/4 3/4 Rated insulation voltage Ui [V] Rated voltage Ue [V] AC DC Rated impulse withstand voltage Uimp [kv] kv Pollution degree Utilization category AC-23A, DC-23A AC-23A, DC-23A AC-23A, DC-23A AC-23A, DC-23A AC-23A, DC-23A Making AC/DC A 320/ /22 120/ / /1000 Making and current cycles 3/ 3/ 3/ braking current Breaking AC/DC A 26/128 04/ / / /1000 current cycles 3/ 3/ 3/ Operational Without current performance With current (440 V/690 V) 6000/ 8000/ 30000/ / /1000 Short-time withstand current Icw 1 s A Short-circuit making capacity Icm 1 s A AC/DC A 192/80 378/1 70/31 960/ /62 Max. switching current a cycles Suitable for isolation V ca a 7 7/100 10/140 10/140 10/140 Dimensions [mm] a c b b c ca Weight [kg] / / / /2.6 Rated data Mechanical data External accessories Cassettetype accessories Accessories connection Installation and connection External operating handle Alarm switch (AL) V Auxiliary switch (AX) V Shunt trip (SHT) V Undervoltage trip (UVT) V with terminal block (SLT) V with internal terminal type b V V V Screw terminal V c V c V c V c V c Front Solderless terminal V V V Busbar terminal V Rear (B) V Rear (PM) V V Plug-in Rear front IP 20 with auto trip (PM-IP) V V V Door mounting (V) V Mounted on breaker (R) V V V Electrical operation device (MDS) V V V Handle lock for use (HL) V Handle lock device with padlock (HL-S) V Lock cover (LC) V Terminal cover Large (TC-L) V Small (TC-S) V V V/ V/ V For rear connection (BTC) V V V/ V/ V Mechanical interlock (MI) V Insulating barrier Between phases (Standard) (BA-F) V Adapter for IEC 3 mm rail V V Corresponding type of circuit breaker NF32-SV NF63-SV NF12-SGV NF160-SGV NF20-SGV a This performance is accordance with IEC clause b On request. c Standard. d Assembly by factory. e TC-N. Missing specifications accord. to IEC/EN on request. 48

18 DSN400-SW DSN630-SW DSN800-SW DSN1000-SW DSN120-SW DSN1600-SW /4 3/4 3/4 3/4 3/4 3/ AC-23A, DC-23A AC-23A, DC-23A AC-23A, DC-23A AC-23A, DC-23A AC-23A, DC-23A AC-23A, DC-23A 4000/ / / / / /6400 3/ 3/ 3/ 3/ 3/ 3/ 3200/ / / / / /6400 3/ 3/ 3/ 3/ 3/ 3/ / / / / / / /18 140/18 210/ / / / /7. 6.2/ / / / /40.7 V a V a V a V a V a V a d V d V d d V d V d e V e NF400-SW NF630-SW NF800-SEW NF1000-SEW NF120-SEW NF1600-SEW 49

19 Order information for moulded-case circuit breakers 3 12 A Type Rated current (In) 3 pole type 4 pole type S series with thermal-magnetic tripping device, fixed, AC 3 A A A A A NF32-SV 1 A A A A A A NF63-SV NF12-SV NF20-SV 3 A A A A A A A A A A A A A A A A A A A A A A A A A H series with thermal-magnetic tripping device, fixed, AC 10 A A A A A NF63-HV 30 A A A A A A Type Rated current (In) 3 pole type 4 pole type S series with thermal-magnetic tripping device, AC, DC A A A A NF12-SGV 3 0 A A A A A NF12-LGV A A A A A A A A A H series with thermal-magnetic tripping device, AC, DC A A A A NF12-HGV 3 0 A A A A A H series with electronic tripping device, adjustable, AC A NF12-HEV A A R series with thermal-magnetic tripping device, AC, DC A A A A NF12 RGV 40 0 A A A A A U series with thermal-magnetic tripping device, fixed, AC, DC 1 A A A A NF12-UV 0 A A A A A

20 Order information for moulded-case circuit breakers A Type Rated current (In) 3 pole type 4 pole type S series with thermal-magnetic tripping device, adjustable, AC, DC NF160-SGV A L series with thermal-magnetic tripping device, adjustable, AC, DC NF160-LGV A H series with thermal-magnetic tripping device, adjustable, AC, DC NF160-HGV A S series with thermal-magnetic tripping device, adjustable, AC, DC A NF20-SGV A A S series with electronic tripping device, adjustable, AC NF20-SEV A A L series with thermal-magnetic tripping device, adjustable, AC, DC A NF20-LGV A A Order information for moulded-case circuit breakers A Type Rated current (In) 3 pole type H series with thermal-magnetic tripping device, adjustable, AC, DC 4 pole type A NF20-HGV A A H series with electronic tripping device, adjustable, AC NF20-HEV A A R series with thermal-magnetic tripping device, adjustable, AC, DC A 214 NF20-RGV A A 2147 U series with thermal-magnetic tripping device, fixed, AC, DC 12 A A NF20-UV 17 A A A A Type Rated current (In) 3 pole type 4 pole type S series with electronic tripping device, adjustable, AC NF400 SEW A NF630 SEW A NF800 SEW A H series with electronic tripping device, adjustable, AC NF400 HEW A NF630 HEW A NF800 HEW A Type Rated current (In) 3 pole type 4 pole type R series with electronic tripping device, adjustable, AC NF400 REW A NF630 REW A NF800 REW A U series with electronic tripping device, adjustable, AC NF400 UEW A NF800 UEW A Order information for moulded-case circuit breakers A Order information for disconnectors DSN series A Type Rated current (In) 3 pole type 4 pole type SS/UR series with electronic tripping device, adjustable, AC NF1000 SEW A NF120 SEW A NF1600 SEW A Type Rated current (In) 3 pole type 4 pole type Disconnectors (no tripping device) DSN32 SV 32 A DSN63 SV 63 A DSN12 SGV 12 A DSN160 SGV 160 A DSN20 SGV 20 A DSN400 SW 400 A DSN630 SW 630 A DSN800 SW 800 A DSN1000 SW 1000 A DSN120 SW 120 A DSN1600 SW 1600 A

MITSUBISHI ELECTRIC. Low Voltage Switchgears Moulded-Case Circuit Breakers Disconnectors. WSS, PSS & Super Series 3 A 1600 A. Technical Catalogue

MITSUBISHI ELECTRIC. Low Voltage Switchgears Moulded-Case Circuit Breakers Disconnectors. WSS, PSS & Super Series 3 A 1600 A. Technical Catalogue Low Voltage Switchgears Moulded-Case Circuit Breakers Disconnectors WSS, PSS & Super Series A 100 A Technical Catalogue 2004 Circuit Breakers Circuit Breakers The new World Super Series WSS completes the

More information

MITSUBISHI NO-FUSE BREAKER NF125-SGW MODEL. In A Ir A 3P Uimp 8kV. 40 C Ue. Icu/Ics 690VAC. 8/8kA 525VAC. POLE Ui690V Cat.A.

MITSUBISHI NO-FUSE BREAKER NF125-SGW MODEL. In A Ir A 3P Uimp 8kV. 40 C Ue. Icu/Ics 690VAC. 8/8kA 525VAC. POLE Ui690V Cat.A. 0 0 0.5 T. 4 0 Ir 10 14 0 0.5 T Ir. 4 10 14 0 0 0.5 T. 4 0 Ir 10 14 0 0.5 T Ir. 4 10 14 ELECTRIC FACTORY AUTOMATI World Super Series POLE Ui90V Cat.A NF5-SGW 100 In A Ir -100A P Uimp kv PUSH TO TRIP 50/0Hz

More information

LOW-VO L TAGE POWER DISTRIBUTION PRODUCTS

LOW-VO L TAGE POWER DISTRIBUTION PRODUCTS LOW-VO L TAGE POWER DISTRIBUTION PRODUCTS Low-voltage Magnetic Contactor Starters 662 Our Power Distribution Products are compact, easy-to-use, built with safety in mind, including the full lineup of Low-voltage.

More information

Molded Case Circuit Breakers Earth Leakage Circuit Breakers. Mitsubishi Molded Case Circuit Breakers and Earth Leakage Circuit Breakers

Molded Case Circuit Breakers Earth Leakage Circuit Breakers. Mitsubishi Molded Case Circuit Breakers and Earth Leakage Circuit Breakers Molded Case Circuit s Earth Leakage Circuit s Mitsubishi Molded Case Circuit s and Earth Leakage Circuit s 1 INDEX 1 3 6 9 Introduction and Features of WS-V Series 1. Outline of Mitsubishi Circuit s 1)

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

Series MOLDED-CASE CIRCUIT BREAKERS & EARTH-LEAKAGE CIRCUIT BREAKERS 07 A EC97J1128

Series MOLDED-CASE CIRCUIT BREAKERS & EARTH-LEAKAGE CIRCUIT BREAKERS 07 A EC97J1128 MOLDED-CASE CIRCUIT BREAKERS & EARTH-LEAKAGE CIRCUIT BREAKERS W o r l d S u p e r Series EC97J11 Mitsubishi Electric Corporation's Fukuyama Works, which produces these products, is certified as meeting

More information

DPX 1600 Electronic release

DPX 1600 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 1600 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

Mitsubishi Breaker Line-up

Mitsubishi Breaker Line-up Mitsubishi Breaker Line-up MCB DIN Series MCCB WS-V Series MCCB WS Series ACB AE-SW Series CP DIN Series December 4 th, 2015 Mitsubishi Electric Corp. Fukuyama Works Page 1 Agenda 1 2 3 LVS Product Overview

More information

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 Functions and characteristics Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63 NT and NW selection criteria Masterpact NT Masterpact NW NT06, NT08, NT10, NT12, NT16 NT06, NT08, NT10

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Low voltage circuit breakers

Low voltage circuit breakers Super Solution North American Edition Low voltage circuit breakers Contents Overview Main characteristics Accessories Technical information Mounting & connection Characteristics curves Dimensions A-1 A-2

More information

ACW Molded-Case Circuit Breaker UL 489 Listed

ACW Molded-Case Circuit Breaker UL 489 Listed Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed Overview Introducing the WEG Series of Molded Case Circuit Breakers now available with UL489 certification.

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX 160 Thermal magnetic and trip-free switches DPX-I 160 87045 LIMOGES Cedex Phone : +33 05 55 06 87 87 FAX : +33 05 55 06 88 88 DPX 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND

More information

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial

More information

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

DPX 630 Electronic release

DPX 630 Electronic release 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS

More information

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch Features (1) All models fully comply with IEC regulations (2) Units can be mounted on a standard 35mm IEC rail (3) Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 630 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

Moulded case circuit breakers

Moulded case circuit breakers Moulded case circuit breakers CONTENT Range 4 Protection Releases 5 Salient Features 8 Accessories, 4 Technical data 2 Time Current Characteristics 5 Overall Dimensions 7 SN4 SN3 SN2 SN 3 RANGE Moulded

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

DPX Electronic + earth leakage

DPX Electronic + earth leakage 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic + earth leakage CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

ACS motor protection circuit breakers KT 7 Introduction

ACS motor protection circuit breakers KT 7 Introduction Introduction Automatic Type 2 coordination The right circuit breaker for all applications The KT 7 circuit breaker family consists of two basic frame sizes of mm and 5 mm in three variations with different

More information

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Specification for 70mm pole pitch Air circuit breaker up to 1600 A Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

MCCB Accessories to suit AF

MCCB Accessories to suit AF MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal

More information

3VT Kompaktleistungsschalter bis 630A

3VT Kompaktleistungsschalter bis 630A Katalog LV 36 AT Österreich - Auszug 2012 3VT Kompaktleistungsschalter bis 630A SENTRON Schutz-, Schalt- und Messtechnik www.siemens.com/lowvoltage 3VT1 Molded Case Circuit Breakers up to 160 A 1 Technical

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage

ME 07 Air Circuit Breakers. ME 07 - Air Circuit Breakers. Low Voltage. Low Voltage. Low Voltage Low Voltage ME 07 - Air Circuit Breakers ME 07 Air Circuit Breakers Low Voltage AEG Niederspannungstechnik GmbH & Co KG Berliner Platz 2-6 D-24534 Neumünster (Germany) Tel. +49/43211-0 Fax +49/43211-144

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Technical Data Accessories MCBs Ex9B.

Technical Data Accessories MCBs Ex9B. Auxiliary and signal contact units AX31, A31, AX31 General parameters With one circuit breaker Ex9B., it can be used up to three contact units with single CO contact or up to two contact units with 2 CO

More information

LOW VOLTAGE SWITCHGEAR

LOW VOLTAGE SWITCHGEAR LOW VOLTAGE SWITCHGEAR S-N Motor Control Mitsubishi Electric s S-N Series contactors are perfect for the control of 3 phase power, either for the direct control of a motor, to supply power to a drive or

More information

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - BNQ BNQD5T BNQD5 with Front Mounting Clips na.noark-electric.com NOARK Ex9 Series - BNQ Features The BNQ is compliant with UL/CSA/IEC standards

More information

DMX 3 -I 2500 switch disconnectors

DMX 3 -I 2500 switch disconnectors 8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40

More information

Molded Case Circuit Breaker

Molded Case Circuit Breaker & The Ultimate Safety Breaker Molded Case Circuit Breaker www.terasaki.co.jp Catalogue No. 13!5E ! Safety Notice Carefully read instruction manual to ensure proper installation, connection, operation,

More information

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter 3 Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter The easy choice for quality, value, and peace of mind Schneider Electric makes it an easy choice

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 DPX 3 250 Electronic Reference(s): 420 302/305/307/309/312/315/317/319/332/335/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

18-I73E CAT REF.

18-I73E CAT REF. & www.terasaki.co.jp 1-I73E CAT REF. TABLE OF CONTENTS General 1-1 Introduction 1- General 1-3 Selection Chart 1- Ratings and Specifications -1 Air Circuit Breakers for DC350V-00V - Moulded Case Circuit

More information

max pole for t=15 ms

max pole for t=15 ms Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole

More information

Motor Protection Circuit Breakers

Motor Protection Circuit Breakers Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions

More information

Molded Case Circuit Breakers H series General information

Molded Case Circuit Breakers H series General information General information Description Models with high breaking capacities Line protection : 15 to 800A Motor protection : 16 to 5A Molded case color : Black Type number nomenclature Series H: H 5 BA / E Q M

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Overview of Low voltage equipment - Moulded-case & Air circuit-breakers Moulded-case circuit-breakers for distribution (1) R16 and R20 Icu = 16 ka @ 220/230 V (2) All the versions with Icu = 35 ka are

More information

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch Features () All models fully comply with IEC regulations () Units can be mounted on a standard 5mm IEC rail () Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Thermal magnetic and trip-free switches

Thermal magnetic and trip-free switches 87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times. The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted power supply is a must. Modern systems are power dependent.

More information

Moulded Case Circuit Breakers

Moulded Case Circuit Breakers Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Data Sheet Manual Motor Starter Ex9S32 Series

Data Sheet Manual Motor Starter Ex9S32 Series Data Sheet Manual Motor Starter Ex9S32 Series na.noark-electric.com NOARK Ex9S32 Series Features Ex9S32 Manual Motor Starter provides manual isolation, manual motor control, and overcurrent protection

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

North American Edition Super Solution Low voltage circuit breakers

North American Edition Super Solution Low voltage circuit breakers www.lsis.biz North American Edition Super Solution Low voltage circuit breakers Low voltage circuit breakers Susol Low voltage circuit breakers Super Solution Contents Overview Main characteristics Accessories

More information

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric. K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles

More information

DRX 125 Circuit breaker (not adjustable)

DRX 125 Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.

More information

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches. Ex9 Series - M. na.noark-electric.

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches. Ex9 Series - M. na.noark-electric. Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches MS50T3L M2N200T3L Ex9 Series - M na.noark-electric.com NOARK Ex9 Series - M Features Molded Case Circuit

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection

More information

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M MS50T3L M2N200T3L na.noark-electric.com NOARK Ex9 Series - M Features Molded Case Circuit

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Low voltage moulded case circuit breaker EB2

Low voltage moulded case circuit breaker EB2 Low voltage moulded case circuit breaker EB2 Product series description unit condition Model-type Number of poles Nominal current ratings Electrical characteristics Rated operational voltage Rated insulation

More information

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE New DMX 3 Efficient protection up to 4 000 A AIR CIRCUIT BREAKERS PRODUCT GUIDE NEW DMX 3 ACBs UP TO 4 000 A EFFICIENT PROTECTION AND CONTROL FOR ALL TYPE OF BUILDINGS 02 Electrical panel equipped with

More information

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 250 B/N/H Circuit breaker (not adjustable) 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 References rences: /18/19/20/21/22/23/24/25/26/27/28/29/ 32/33 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. MOUNTING 2 5.

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

Miniature circuit breakers. Residential current circuit breaker. Busbar systems. Comfort functions/energy control. Residential enclosures

Miniature circuit breakers. Residential current circuit breaker. Busbar systems. Comfort functions/energy control. Residential enclosures .2....6 special versions High performance range H for 000V/AC Circuit breaker for 7V/DC DC circuit breaker up to 0V/DC Miniature circuit breakers A.7.8.0 Technical data Economy range N, V/AC Standard range

More information

Circuit protection and control devices 0.5 to 6300 A

Circuit protection and control devices 0.5 to 6300 A Electrical distribution Circuit protection and control devices 0.5 to 6300 A LV product characteristics 2009 m TOOLS schneider-electric.com The technical guide This international site allows you to access

More information

Data Sheet Manual Motor Starter Ex9S32 Series

Data Sheet Manual Motor Starter Ex9S32 Series Data Sheet Manual Motor Starter Ex9S32 Series na.noark-electric.com NOARK Ex9S32 Series Features Ex9S32 Manual Motor Starter provides manual isolation, manual motor control, and overcurrent protection

More information

Interruption Technology of Breakers for High-voltage Direct Current

Interruption Technology of Breakers for High-voltage Direct Current Interruption Technology of Breakers for High-voltage Direct MORIAI Hiroshi ABSTRT Applications for direct current () electric distribution have been spreading along with the increase of data centers and

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

Molded Case Circuit Breaker

Molded Case Circuit Breaker Molded Case Circuit Breaker + + + Building + + + a better + + future + + + + We, Hyundai Heavy Industries Co., Ltd., are challenging + + + + for better + future with + continuous + investment + in R&D

More information

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories Circuit Breakers BZM Product Information Circuit Breaker BZM1 16 to 125 A Circuit Breaker BZM2 125 to 250A BZM1 & BZM2 Accessories Optimum and Efficient Protection for Every Application Compact Simple

More information

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue

Low voltage. Masterpact NT and NW. LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type. Catalogue Low voltage Masterpact NT and NW LV power circuit breakers and switch-disconnectors Draw-out Type & Fixed Type Catalogue 2015 Functions and characteristics Circuit breakers and switch-disconnectors NT06

More information

15-I73E CAT REF.

15-I73E CAT REF. & www.terasaki.co.jp 5-I7E CAT REF. TABLE OF CONTENTS General - Introduction - General - Selection Chart - Ratings and Specifications - Air Circuit Breakers for DC50V-00V - Moulded Case Circuit Breakers

More information

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

IP20 degree of protection; IP40 degree of protection after installation in a distribution box RI 50 RI 50 is used for the protection of installations and devices (overload and short circuit), and as a disconnector in case of electric shock Simple and quick fixing to a 35 mm mounting rail in accordance

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

Power protection solutions

Power protection solutions Power protection solutions DMX A.C.Bs UP TO 4000 A In high power installations, the role of the main enclosure is to: - House protection devices and provide for their connection - Provide management and

More information

LSIS UL MCCB & Accessory

LSIS UL MCCB & Accessory LSIS UL MCCB & Accessory UL MCCB 100/150/250/400/600/800/1200AF UL MCCB Accessory 100/150/250/400/600/800/1200AF No. Specification 100AF 150AF 250AF 400AF 600AF 800AF 1200AF 1 2 3 4 5 6 7 8 9 10 11 12

More information

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V DC circuit supplementary protectors for feeders / distribution systems C60H-DC C curve DB123430 DB123525 DB405571 IEC 60947-2 PB107193-34.eps PB107194-34.eps The C60H-DC supplementary protectors are used

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

Low voltage circuit breakers

Low voltage circuit breakers Comprehensive Catalogue 2006 Super Solution Low voltage circuit breakers A-3. Accessories TD & TS MCCB Index Electrical auxiliaries Undervoltage release, UVT Shunt release, SHT Auxiliary switch (AX),

More information