HYDRAULIC POWER UNIT PUP SERIES G-O5 OPERATION, MAINTENANCE, AND REPAIR MANUAL
|
|
- Dorthy Nelson
- 6 years ago
- Views:
Transcription
1 HYDRAULIC POWER UNIT PUP SERIES G-O5 OPERATION, MAINTENANCE, AND REPAIR MANUAL nd AVENUE NORTH * MOORHEAD, MN, USA PHONE (28) * FAX (28) ADDRESS; info@portaco.com * INTERNET ADDRESS:
2 TABLE OF CONTENTS.0 Introduction. General Information.2 Features.3 Options.4 Safety Summary.5 General Safety Precautions.6 Warning and Caution Statements.7 Training Requirements 2.0 Installation Instructions 2. Unpacking Instructions 2.2 Engine Preparation 2.3 Hydraulic Power Unit Preparation 2.4 Testing 2.5 Adjustments 2.6 Hose Requirements 2.7 Tool Connecting Procedures 2.8 Work Area Safety Precautions 3.0 Operating Instructions 3. Description of Power Unit 3.2 Controls and Graphics 3.3 Before Start Up 3.4 Positioning the Power Unit 3.5 Startup 3.6 Shutdown 3.7 Cold Weather Operation 3.8 Storage Preparation 4.0 Maintenance Instructions 4. Routine Servicing and Inspection Schedule 4.2 Assembly View and Parts List 4.3 Hydraulic Fluids and Lubrication 4.4 Trouble Shooting 4.5 Technical Specifications
3 .0 INTRODUCTION. General Information This manual presents installation, operation, and maintenance information for PortaCo Hydraulic Power Unit model G-O5SO5-O8-O (Pup Series). PortaCo, Inc. reserves the right to make changes at anytime without notice and without incurring any obligation. The G-O5 unit produces a maximum flow of 20 LPM (5.3 GPM) and a maximum pressure of 23.2 BAR (800 PSI). This power source provides the required flow and pressure to operate HTMA Type I class hydraulic tools. Only OPEN-CENTER tools requiring a flow of 5-23 LPM (4-6 GPM) and a maximum pressure of 38 BAR (2000 PSI) should be used with the G-O5 power unit. CAUTION: DO NOT USE CLOSED- CENTER TOOLS WITH THIS POWER UNIT.2 Features The main features of the PortaCo G- O5 are as follows: Standard unit is a skid style frame. Length 59.6 cm (23.5 in) Width 43. cm (7.0 in) Height 4.9 cm (6.5 IN) Weight dry 38. kg (84 lbs.) Upper ambient operating temperature 40 C (04 F) Lower ambient operating temperature -20 C (-4 F) The standard engine is a 5.5 HP, 4 stroke, overhead valve, single cylinder, and Honda GX60 engine. The GX-60 engine weighs 4.0 kg (3lbs) and runs on regular gasoline (86 pump octane: Unleaded is recommend by the engine manufacturer)..3 Options The G-O5 power unit may be equipped with one or more of the following options if ordered or added after base model purchase. - Briggs and Stratton OHV engine rated at RPM - Kohler OHV engine rated at 4000 RPM - Bolt on wheel and handle bar kit (P/N OOK).4 Safety Summary Tool operators and maintenance personnel must always comply with the safety precautions given in this manual and on the stickers and tags attached to the tool and hoses. These safety precautions are given for your safety. Review them carefully before operating the power unit and before performing maintenance or repairs. Supervising personnel should develop additional precautions relating to the specific work area and local safety regulations..5 General Safety Precautions The PortaCo Inc. G-05 Hydraulic Power Unit is designed to provide safe and dependable service if
4 operated according to the instructions provided in this manual. Read and understand this manual and any stickers attached to the power unit before operating. Failure to do so could result in personal injury or equipment damage. Check the rules and regulations at your location. The rules may include and employer s work safety program. Regulations may identify hazards such as working around utility supply lines or hazardous slopes..6 Warning and Caution Precautions.7 Training Requirements Operator training should consist of information found in this manual for the hydraulic power unit. In addition the operator must receive instructions both through demonstrations and verbally with the tools or applications in which the power unit is going to be used. The new operator must start in an area without bystanders and use all controls until able to fully operate the power unit under the conditions for the work area. Warning and Caution statements have been strategically placed throughout the text prior to operating or maintenance procedures, practices, or conditions considered essential to protection of personnel or equipment and property. WARNING: HIGHLIGHTS AN ESSENTIAL OPERATING OR MAINTENANCE PROCEDURE, PRACTICE, CONDITION STATEMENT, ETC. WHICH IF NOT STRICTLY OBSERVED, COULD RESULT IN INJURY TO, OR DEATH OF, PERSONNEL OR LONG TERM HEALTH HAZARDS. CAUTION: HIGHLIGHTS AN ESSENTIAL OPERATING OR MAINTENANCE PROCEDURE, PRACTICE, CONDITION STATEMENT, ETC. WHICH IF NOT STRICTLY OBSERVED, COULD RESULT IN DAMAGE TO, OR DESTRUCTION OF, EQUIPMENT OR LOSS OF MISSION EFFECTIVENESS.
5 2.0 INSTALLATION INSTRUCTIONS 2.3 Hydraulic Power Unit Preparation 2. Unpacking Instructions CAUTION: DO NOT OPERATE POWER UNIT WITH BELOW RECOMMENDED HYDRAULIC OIL LEVEL. PUMP DAMAMAGE MAY ACURE. Upon receiving your PortaCo G05S hydraulic power unit promptly remove it for shipping container. Always keep top side of container up. Inspect unit for damage which may have incurred during shipping and report it to carrier for claim. 2.2 Engine Preparation CAUTION: ALWAYS CHECK ENGINE OIL BEFORE STARTING POWER UNIT. Make sure engine oil is at the FULL mark on the dipstick. Fill fuel tank with petrol and to the level recommended by the engine requirements and procedures. Figure 2.2A shows location of engine oil dipstick. (Arrow A) NOTE: clean up oil and fuel spills immediately. Do not over fill fluids. B A C Figure 2.2A Check hydraulic fluid level by looking at sight pipe located on top of the oil reservoir. Proper oil level is indicated when the center section of the sight pipe is dark. To add hydraulic fluid remove filter cap on top of reservoir, replace when finished. Reservoir capacity is 6.6 LTR (.74 gal) do not overfill fluids, clean up oil spills immediately. Only hydraulic fluids meeting the specifications located below are recommended for use with PortaCo hydraulic power units. Viscosity (Fluid Thickness) METRIC U.S.A. 0 C 95 Centistokes 50 F 450 SSU Max 38 C C.S. 00 F SSU 60 C 6.5 C.S, Min. 40 F 85 SSU Min. Pour Point-0 F/23 C Minimum (for cold startup) Viscosity Index (ASTM D 2220) 40 Minimum Demulsibility (ASTM D-40) 30 Minutes Maximum Flash Point (ASTM D-92) 340 F/7 C Minimum Rust Inhibition (ASTM D-665 A & B) Pass Oxidation (ASTM D943) 000 Hours Minimum Pump Wear Test (ASTM D2882) 60 mg Maximum The following fluids work well over a wide temperature range at startup, allow moisture to settle out, and resist biological growth likely in cool operating hydraulic circuits. These fluids are recommended by PortaCo, Inc. Other fluids that meet or exceed the specifications of these fluids may also be used.
6 Type Chevron Exxon Mobil Gulf Shell Texaco Union Amsoil Sunvis Hydraulic fluid Clarity AW 5032 Univis J 32 D.T.E. 3 M Harmony AW-HVI Tellus T 32 Rando HDZ 32 Unax AW-WR-32 AWH 5032 Low Pour H/032-product code Testing All power units are tested at the factory and their flows and pressures are recorded on the test report, which is shipped with the power unit. Testing of the power unit is not required unless it is damaged during shipping. Always perform before startup procedures found in section 3.3 before testing. PortaCo Hydraulic Tester, Part Number T-0006-XX-0 is recommended for all tests. a. Set the hydraulic circuit to OFF. b. Connect hydraulic hoses to the power unit. Connect the PortaCo Hydraulic Tester to the opposite end of the hoses. Make sure flow direction is correct. c. Start the engine and allow the hydraulic fluid to warm to about 00 F/38 C. d. Open the tester restrictor valve (fully open.) This represents minimum load. e. Set the flow control to ON and set engine throttle for maximum speed. f. Check the flow rate and pressure on the tester gauges. Flow should be 20 lpm (5.2gpm) and pressure should be under 7.3 bar 250 psi) back pressure. g. With engine throttle set at maximum speed slowly close the restrictor valve on the tester while observing the flow pressure gauges. h. As the hydraulic system relief valve begins to crack (open) and bypass fluid through the valve, the flow rate will begin to drop. At this time, the pressure in the system should be between 9 and 33 bar/700 and 900 psi. i. If the pressure is not as specified, the hydraulic circuit relief valve must be adjusted or replaced. (See section 4.2 for procedure.) - If the flow rate drops below Bar ( psi), the pump or control valve may be worn. - If the flow remains constant, but pressure does not increase, the relief valve may be defective. 2.5 Adjustments The engine RPM s and the hydraulic system flow and pressure relief are set at the factory and must not be readjusted. DO NOT change governor setting or tamper with governor components, which may increase the governed engine speed. WARNING: OPERATING THE POWER UNIT AT EXCESSIVE SPEEDS INCREASE THE DANGER OF PERSONAL INJURY. 2.6 Hose Requirements The G-05 is easily moved close to the job site. It is not often necessary or advisable to use long hoses. Use two 3/8-inch diameter hoses, 5 to 8 m long /5 to 25 ft. Rated for a
7 working pressure of at least 75 bar /2500 psi. All hoses must have an oil resistant inner surface and an abrasion resistant outer surface. Each hose must have male pipe ends for most application. Longer hoses can be used when necessary, but can affect the operation of the engine due to resistance in the hose. Use ½-inch diameter hose rated at 75 bar (2500 psi)operating pressure if longer hose is required. If small diameter or long hoses are used, or if restrictive fittings are connected to the supply and return ports, the pressure required to push the fluid through the system and back to the tank will be higher. This will reduce tool power. The pressure and return hose are connected to the control block. A ½inch male pipe hose end can be connected, to H.T.M.A. flat-nosed quick-disconnect couplings (available through your PortaCo, Inc. dealer) can be used. (see fig. 2.6A) The upper port of the control block is the pressure (oil out) fitting. A male H.T.M.A. quick-disconnect coupling (without lock ring) must be connected to the tool end of the hose, which is connected to this port. *Important Oil should always flow from the male coupler through the female coupler. The lower port is the return port. A female H.T.M.A. quick-disconnect coupling should be connected to this port. NOTE: The pressure increase in uncoupled hoses left in the sun may make them difficult to connect. When possible after use, connect the free ends of the operating hoses together. HOSE TYPES Hydraulic hose types authorized for use by PortaCo, Inc. is as follows:. Labeled and certified nonconductive 2. Wire braided (conductive) 3. Fabric braided (not certified or labeled non-conductive) Hose : Listed above is the only hose authorized for use near electrical conductors. Hoses 2 and 3: Listed above are conductive and must never be used near electrical conductors. HOSE PRESSURE RATING The rated working pressure of the hydraulic hose must be at least 75 bar (2500 psi.) 2.7 Tool Connecting Procedures. Inspect hose for cuts, crushing, leaks, or abrasion which maybe a safety hazard or reduce fluid flows. WARNING: DO NOT ATTEMPT TO LOCATE HYDRAULIC LEAKS BY FEELING AROUND HOSES AND FITTING WITH HANDS. PIN-HOLE LEAKS CAN PENETRATE THE SKIN.
8 Stop the engine before connecting the tool and, or hoses to the off power unit, and when switching hoses or tools. Turn the hydraulic on/off valve to the off position before starting the engine. Make sure all hose are connected for correct flow direction to and from the tool being used. When routing hose in the work area, position them where personnel will not be at risk of tripping over them where vehicles can run over the hoses. Do not lay hose over sharp projects. WARNING: PRESSURIZED FLUID ESCAPING FROM A DAMAGED HOSE CAN PENETRATE THE SKIN AND BE INJECTED IN THE BODY CAUSING INJURY OR DEATH. storing the power unit in an enclosed space. - PortaCo hydraulic power units must not be located below overhead gantries, power lines, or walkways where there might be a risk of falling objects. - Provide ambient light intensity of 200 Lux for working indoors or outdoors particularly if working at night. - Always wear appropriate safety equipment such as goggles, ear protection, and foot protections. - Operate only tools which fit into the specifications prescribed in section. of this manual. - Do not stand on power unit. CAUTION: DO NOT PULL ON HOSES TO DRAG POWER UNIT. 2.8 Work Area Safety Precautions - Never operate the power unit in a closed space. Inhalation of engine exhaust can be fatal. - Keep clear of hot exhaust. - Do not use PortaCo hydraulic power units in potentially explosive atmospheres such as near wastewater drains or landfill sites. - Do not operate if flammable gases or vapors are present. - Keep the power unit at least meter (3.3 ft) away from buildings, obstructions, and flammable objects. Do not aim engine exhaust at materials that could catch fire. - Allow the engine to cool before
9 3.0 Operating Instructions 3. Description of Power Unit The PortaCo G-05 series Hydraulic Power Unit has been designed for the purpose of supplying hydraulic fluid under pressure to power hydraulic hand tools. PortaCo power units produce a maximum pressure of 23.2 bar (800 psi) and a maximum flow rate of 20 lpm (5.3 gpm) at 3500 rpms. A petrol engine having a pull cord starting systems powers the PortaCo hydraulic power unit. The standard engine used in the Honda Model GX60 rated at 5.4 Hp. Other optional engines are the Briggs and Stration OHV 5.5 hp and the Kohler OHV 6.0 hp. See the technical manuals supplied by the engine manufacture included with this power unit for detailed technical specifications. PortaCo Hydraulic Power Units have been designed for use indoors and outdoors. Portaco power units should not be operated under wet conditions, or at ambient operating temperatures, outside the recommended temperature range of 0 c to 40 c. (-4 F to 04 F) The G-05 hydraulic power unit provides the required flow and pressure to operate HTMA Type class hydraulic tools. Only OPENCENTER tool s requiring a flow of 5-23 LPM (4-6) gpm and a maximum pressure of 38 bar (2,000) psi should be used with the PortaCo G-05 Hydraulic Power Unit. CAUTION: DO NOT USE CLOSEDCENTER TOOLS WITH THIS POWER UNIT. During operation, the engine may bog, run at lower rpm, when under load. As the tool being used is loaded, meets with increase resistance, the pressure required to operate the tool increases. The increased pressure adds load to the pump which loads the engine there by reducing the rpms. As a result, the flow will drop as pressure increases. The hydraulic system has a pressure limiter set at 23.2 bar (800 psi) which diverts the flow back to tank until the pressure drops below 23.2 bar (800 psi.) Tools with higher flow and, or pressure requirements will not operate at their full potential if used with the PortaCo Hydraulic Power Unit. Tool with lower flow and, or pressure requirements may be damaged if used with this power unit. The engine throttle and the hydraulic system relief value are preset at the factory and must not be altered for any reason without consulting PortaCo Inc. Any alterations approved by PortaCo Inc., can only be preformed by personnel qualified to maintain hydraulic systems. Tools which are commonly used with PortaCo s G-05 Hydraulic power unit are as follows: Impact Wrenches.Tampers Impact Drills Hand Held Saws Picks Hand Held Pruners Handheld grinders..breakers
10 Do not use the G-05 power unit with close-center tools, tools which do not allow the oil to return to the power unit when not activated. Do not use in jacking operations. Do not use to activate cylinders without an inline open-center control system. Do not operate without a return oil hose. If there is any doubts weather your tool can be used with the PortaCo G05 unit please contact the service department at PortaCo Inc. ( ) for advice. PortaCo Inc. accepts NO responsibility for machines that are used for any purpose other than the intended purpose as specified in the operating instructions or approved directly by PortaCo Inc. 3.2 Controls and Graphics WARNING: FAILURE TO FOLLOW THE PROCEDURES LISTED IN THE ENGINE S OWNER S MANUAL COULD RESULT IN PERSONAL INJURY OR EQUIPMENT DAMAGE. This decal is located next to the sight tube on the top side of the hydraulic tank. (Fig. 3.2F Arrow B). Figure 3.2A The on/off control for the hydraulic system is labeled with a decal indication the direction of rotation for on and off positions. (Fig 3.2B) The control knob is located in the lower left corner of the hydraulic tank just above the hose couplers (Fig. 3.2F Arrow A). Refer to the engine owner s manual for explanation of controls and symbols located on the engine. The following decals are placed on the power unit to aid in its operation and maintenance. The operator should locate and understand them before using this power unit. The hydraulic fluid reservoir decal instructs the operator on fluid level requirements, filter changing intervals, and recommended fluids to be used. (Fig 3.2A). Figure 3.2B The oil reservoir cap is marked with a hydraulic oil decal. Fig 3.2C The reservoir fill cap is located in the center of the tank (Fig. 3.2F Arrow C).
11 Figure 3.2C Figure 3.2E C The hydraulic work parts are labeled respectively as to their function with the decals in Fig 3.2D. The upper port is pressure (arrow D Fig 3.2 F) and is equipped with a male quick coupler. The lower port is return (arrow E Fig 3.2F) and is equipped with a female quick coupler. B D A F E Figure 3.2F 3.3 Before Start Up Figure 3.2D A PortaCo serial number decal is attached to the power unit on the back side of the hydraulic fluid reservoir (Fig. 3.2F). The serial number tag displays PortaCo s address and phone number in addition to the units model number, serial number, and other technical specifications (fig 3.2E). Check engine oil level, engine air filter, and fuel level. Refer to the engine manual for proper procedures when checking, filing, cleaning, or replace any engine components and fluids. Check the hydraulic oil reservoir level looking at the sight tube located on top of the reservoir. An instructional decal is next to the sight gauge with instructions and fluid specifications (Fig 3.2A and Fig 3.2F). Check fluid by sight table with engine at IDLE. No dark spot..add fluid, half guage dark..ok, gauge tube fulldark..full. Add fluid with engine off fill until sight table indicates full (Fig 3.3A Arrow C.)
12 Drain reservoir and change the filter every 200 hrs of use or seasonal which ever is more frequent. Hydraulic oil reservoir hold 6.6 liters (.75 gallons) and is drained by removing the hydraulic oil filter (Arrow B Fig 3.3A) Before using the G-05 power unit inspect the oil cooler grill (Fig. 3.3 A Arrow A) for blocking or contamination. The power units must be free of leaves, dirt, oil, and other contaminants which may inhibit cooling or create a fire hazard. Use compressed air or a pressure washer to keep unit clean. INJECT OIL INTO THE BODY RESULTING IN DEATH. Do not use hoses, couples, or fittings which are damaged, replace immediately. See section 2.8 of this manual for additional safety procedures. 3.4 Positioning the Power Unit The PortaCo G-05 power unit can be carried to the job site by lifting the unit by frame. Carrying the unit two men, one on each end of the frame. Do not tilt power unit more than 20 degrees while carrying. (Fig. 3.4A) C A B Figure 3.3A Figure 3.4A Check that fasteners and fittings are tight, and tighten any fittings which may develop a leak or fasteners that may become loose immediately. Hydraulic hoses and couples should be inspected for wear, cracking, or fatigue prior to starting the engine. Place the PortaCo hydraulic Power Unit on a level surface with no greater than a 20 degree slope to prevent fuel spillage and power unit movement. WARNING: NEVER INSPECT PRESSUREIZED HOSES, COUPLERS, OR FITTINGS WITH HANDS OR AT CLOSE DISTANCES. PRESURIZE FLUID CAN PUNTURE THE SKIN AND WARNING: PLACING THE PORTACO G-05 HYDRAULIC POWER UNIT OR EXCESSIVE SLOPES OR UNSTABLE GROUND COULD CAUSE THE UNIT TO ROLL OR TIP DAMAGING THE POWER UNIT OR ENDANGERING WORKERS.
13 Locate hydraulic power unit in well, lit area with a minimum ambient light intensity of 200 lux weather indoors or outdoors, particularly at night. Keep the power unit at least meter (3.3ft) away from buildings, obstructions, and flammable objects. Do not aim engine exhaust at materials that could catch fire. 3.5 Start Up (A) Observe all safety precautions found through out this manual and the included engine manual. (B) Connect the hoses to the tool and then to the G-05 power unit. NOTE: Clean ends of couplers before connecting to prevent system contamination. (C) Turn the control value fully counterclockwise (OFF). (See fig. 3.5A) Figure 3.5B (E) After the engine has warmed up, engine speed can be controlled by the control lever. Move the control lever to full throttle. (F) Position the control value fully clockwise ON to supply hydraulic power to the tool. (See fig. 3.5A) *Important Make sure the control value is in the full counterclockwise position before connecting or disconnecting hoses to the tool. Tools used with the G-05 must be designed for operation with opencenter systems. 3.6 Shutdown A. NORMAL SHUTDOWN Figure 3.5A (D) Start engine (see Engine Manual for starting procedure) and adjust the choke lever to keep the engine running for 3 to 5 minutes while leaving the control lever unchanged. (See Fig. 3.5B for engine control locations.) *Important Always turn the control valve OFF before setting the Engine Switch to OFF. Stopping the engine with the control lever ON, can cause the exhaust system to load with gasoline during coast down. This can cause damage to the exhaust system.
14 ) Observe all safety precautions 2) Turn the control valve fully counterclockwise. 3) Move the engine control lever up to the minimum (START) position. 4) Maintain the engine at idle for a short time; then set the engine switch to OFF. (Fig. 2.2A Arrow B.) 5) Disconnect the hoses from the power unit pressure hose first. Then disconnect hoses from the tool. When possible after use, connect the free ends of the operating hoses together. The pressure increase in uncoupled hoses left in the sun may make them difficult to connect. 6) Allow the hydraulic power unit to cool down before enclosing in a small area for transportation or storage. B. EMERGENCY SHUTDOWN In the event of an emergency, such as fire, immediately set the engine switch to OFF. (Fig. 2.2A Arrow B) 3.7. Cold Weather Operation Hydraulic fluids are thicker in cold weather; therefore, run the engine at low idle long enough to bring the fluid temperature up to minimum of 0 C/50 F or until the top of the hydraulic tank feels warm. Run the engine (and pump) at low speed with the control valve fully counterclockwise until the engine and hydraulic system are warm. This will reduce pressure in the hoses causes by cold fluid. In cold weather, a cover over the cooler (not the engine duct) will allow faster warm-up. (Arrow A Fig. 3.3A) 3.8 Storage Preparation To prepare the engine for transportation or storage refer to the engine owners manual. To prepare the hydraulic system for storage fill the hydraulic oil reservoir to the full mark, and check that the fill cap and filter are tight. When removed from storage during a 3 month or longer period, drain the hydraulic oil reservoir and replace the hydraulic oil filter. (See section 4) This will remove any water which, may have condensed in the hydraulic oil reservoir during storage. Store the PortaCo G-05 hydraulic power unit on a smooth level surface. The power unit should be stored in a cool, dry environment which is not subjected to rapid temperature changes.
15 4.0 Maintenance Instructions 4. Routine Servicing and Inspections Schedule Maintenance Schedule (Preformed at every indicated month or operating interval, whichever comes first.) Regular Service Period ITEM Engine Oil Air Cleaner Check level Change Check Clean Clean Check- Clean Clean Sediment cup Spark plug Spark arrester (optional part) Valve clearance Check -Adjust Fuel tank and strainer Clean Fuel line Check (replace if necessary) Hydraulic system Check fluid level Change oil and filter Remove condensation from fluid Inspect hydraulic system for leaks Pump coupling Check (Replace if necessary) Hose Assemblies Check (Internal) (Replace if necessary) Test Hydraulic Check Flows and pressures. (service as required) Each Use or 8 Hrs. o First Month or 20 Hrs. Every 3 month or 50 Hrs. o Every 6 months or 00 Hrs. Every year or 300 Hrs. o o o () o o o o (2) o (2) Every 2 years (2) o o o o Every 2 years (3) Every 2 years (3) Every 2 years (3) (see section 2.4 for testing NOTE: (): Service more frequently when used in dusty areas. (2): These items should be serviced by an authorized Honda dealer, unless the owner has the proper tools and is mechanically proficient. See the Honda Shop Manual. (3): These items should be serviced by a qualified Hydraulics Technician. Service Replacements Parts Description Filter Hydraulic Oil 0 micron twist on Engine Air Filter Part Number 763-OOP BE-0-8 See Engine Manual Source PortaCo Inc. ZINGA
16 CAUTION: USE ONLY GENUINE PORTACO INC PARTS OR EQUIVALENT. THE USE OF REPLACEMENT PARTS WHICH ARE NOT OF EQUIVALENT QUALITY MAY DAMAGE THE HYDRAULIC POWER UNIT. 4.2 Assembly View and Parts List PARTS LIST G-05 MODEL PUP SERIES ITEM NO PARTS NO OOP 04-OOP 044-OOP 062-OOP VOID 063-OOP 064-OOP 085-OOP 094-OOP 099-OOP 06-OOP 59-OOP 2098-OOP 58-OOP 75-OOP 76-OOP 96-OOP 22-OOP 324-OOP 363-OOP 238-OOP 46-OOP 444-OOP 446-OOP 759-OOP 763-OOP 3034-OOP 767-OOP 768-OOD 095-OOP 940-OOP 949-OOP 656-OOP 2072-OOD 2077-OOP DESCRIPTION QUANITITY FITTING 38 x 2.5 NIPPLE 2 NUT JAM 3 BOLT ¼ NC X ¾ 8 NUT ¼ 0 LOCK WASHER 3/8 LOCK WASHER ¼ CLAMP NUT 5/6 WASHER, ¼ FLAT PLATED NUT 3/8 MOUNT FOOT VALVE, RELIEF PUMP WASHER, LOCK 5/6 PLATED WASHER FLAT 5/6 SCREW BOLT ¼ X ½ BOLT 3/8 X BOLT 5/6 X FITTING CLAMP HOSE FITTING FITTING FITTING FILTER MAINFOLD CAP HYDRAULIC FILL GAUGE SITE BOLT 5/6 X ¼ VALVE FITTING WASHER FLAT MAINFOLD FILTER HYD SCREW
17 OOP 274-OOP 2057-OOP 253-OOP 2554-OOP 224-OOP OOP 252-OOP OOP 2828-OOP 2829-OOD 733-OOP 283-OOD 2832-OOD 3560-OOW 2834-OOW 960-OOD 2836-OOP 2837-OOW 2838-OOP 394-OOD VIOD 284-OOP 2842-OOP 2843-OOP 2844-OOP VOID 2846-OOP 2448-OOD 2880-OOD BOLT ¼ X FOOT BOLT ¼ X FITTING COUPLER HYDRAULIC MALE DUST COVER MALE (NOT SHOWN) COUPLER HYDRAULIC DUST COVE FEMALE (NOT SHOWN) FITTING ENGINE HONDA 5.5 HP GUARD FAN AT ENGINE BOLT, ¼ X ½ SOCK HEAD COUPLER PUMP TO ENGINE FAN MOUNT PUMP FRAME SPACER, FOOT TRIM /8 TANK HYDRAULIC O-RING SPACER COOLER HOSEN PRESSURE HOSE ½ X 4.5 HOSEN ½ X 2 HOSE ½ X 8 PANEL SIDE PANEL, FILLER
18
19
20 4.3 Hydraulic Fluid and Lubrication WARNING: SHUT OFF ENGINE BEFORE DOING ANY MAINTENANCE. TO PREVENT ACCIDENTAL START-UP, TURN OF THE ENGINE SWITCH OFF AND DISCONNECT THE SPARK PLUG CAP. - - Engine Maintenance Always check the engine oil level, and change the engine oil at the internals specified in the engine literature supplied with the power unit. Use engine oil drain plug indicated by arrow C in figure 2.2A. Hydraulic Fluid Servicing The following are instructions for removing condensed moisture, and fluid and filter changing Place funnel device under hydraulic filter to direct oil into clean 8 leter (2gallon) container. Remove oil filter and allow tank to drain completely. Apply a film of fluid to the gasket surface of new hydraulic oil filter. PortaCo Inc. number 763-OOP (ZINGA P/N BE-0-8.) Install new filter element and tighter one-half turn after initial gasket contact. When removing moisture, let fluid sit to allow moisture to settle out. Then pour fluid back into tank avoiding the water at the bottom of the container. Once a year replace oil with clean new hydraulic fluid. Please dispose of used fluids in a manner that is compatible with the environment. PortaCo Inc. suggests you take it in a sealed container to your local service station for reclamation. DO NOT throw it in the trash or pour it on the ground. Fill hydraulic oil reservoir with a fluid recommended in section 2.3 of this manual. Fill reservoir until the gauge indicates full. Reservoir capacity 6.6 leters (.74 gallons) see section 3.3 for instruction on how to read hydraulic level gauge. CAUTION: ALWAYS FOLLOW ANY HANDLING PRECAUTIONS PUBLISHED BY THE MANUFACTURES OF THE LUBRICANTS OR HYDRAULIC FLUIDS USED. - Start engine and allow to run at idle for 3 minutes Shut engine off, check oil level and add fluid if required. Do not overfill or fluid may be forced out of hydraulic fill cap when operating unit. To maximize life of the PortaCo Inc. Hydraulic Power Unit all maintenance must be preformed in accordance with the manual and the engine manual provided.
21 4.4 Trouble Shooting Problem Engine will not start Cause Engine Switch OFF Engine oil low Fuel valve OFF Fuel level low Fuel not reaching carburetor No spark at spark plug None of the above Engine runs but hydraulic circuit will not drive tools. ON-OFF valve OFF Tool not connected to power unit Hydraulic fluid reservoir low Damaged couplers or hoses Tool hoses incorrectly connected to circuit Relief valve stuck open. Engine runs but hydraulic circuit will not drive tool Tool runs too hot Tool is defective Remedy Turn engine switch ON. Add engine oil if requred True fuel valve ON Add fuel Refer to engine manual for proper procedure Refer to engine manual for proper procedure Take the engine to an authorized dealer that represents the manufacturer of the engine your power unit is equipped with. Turn valve ON Turn valve OFF, connect tool, turn valve ON Check and fill as required Check that couplers and hoses are in good condition, replace as required Check that hoses connect pressure from power unit to pressure inlet of tool, and Return at power unit connects to return outlet of tool. Clear blockage (see section 4.2) replace if required. Repair as necessary Relief value set too low Adjust cracking pressure to 23.2 bar (800 psi) Hoses too small Size hose as require in section 2.6 Cooler blocked Clean hydraulic oil cooler Tool Doesn t meet See section. for system system specifications specifications Closed-center tool in Use only open-center tools use
22 4.5 Technical Specifications Hydraulic power unit dry weight Engine weight (dry) Honda* Gx60 Max pressure Max flow Relief value setting Engine rpm Max. Honda* GX60 Hydraulic reservoir capacity Fuel rank capacity Honda Gx60* Engine oil capacity Honda Gx kg (84 lbs.) 2.0 kg (26.5 lbs.) 23.2 Bar (800 psi) 20. leter (5.3 gpm) 23.2 Bar (800 psi) 4,000 rpm 6.6 leters (.74 gallons) 3.6 leters (.95 gallons).60 leter (.63 us qt) SAE 0W-30 is recommended for general all temperatures use by the engine manufacturer.
23 Consumable Items List Filter hydraulic oil: PortaCo Inc P/N P ZINGA P/N BE-0-8 Filter Air Honda GX60 Engine: See authorized Honda dealer Spark Plug Honda GX60 Engine: BPGES BPRGES (NGK) W20EP-U W20EPR-U (NIPPONDENSO) *If the hydraulic unit is not equipped with the Honda engine refer to engine manual provided for specifications. Hydraulic Fluid Requirements Viscosity (Fluid Thickness) METRIC 0 C 95 Centistokes 38 C C.S. 60 C 6.5 C.S., Min. U.S.A. 50 F 450 SSU Max 00 F SSU 40 F 85 SSU Min. Pour Point 0 F/-23 C Minimum (for cold startup) Viscosity Index (ASTM D 2220) 40 Minimum Demulsibility (ASTM D-40) 30 Minutes Maximum Flash Point (ASTM D-92) 340 F/7 C Minimum Rust Inhibition (ASTM D-665 A & B) Pass Oxidation (ASTM D943) 000 Hours Minimum Pump West Test (ASTM D2882) 60 mg Maximum Recommend Hydraulic Fluids Type Chevron Exxon Mobil Gulf Shell Texaco Union Amsoil Sunvis Hydraulic fluid Clarity AW ISO 32 Univis J 32 D.T.E. 3 M Harmony AW-HVI Tellus T 32 Rando HDZ 32 Unax AW-WR-32 AWH ISO 32 Low Pour H/032-product code Hose Requirements; (2) 3/8-inch diameter hose 5-8 meter (5 to 25 feet) long with 75 Bar (2500 psi) minimum rated working pressure.
24 Coupler recommendation: 3/8 inch FLAT FACE HTMA couplers rated at 2500 psi working pressure. Threads are to match fittings used of on hoses or fittings used as adapters. Operate PortaCo Hydraulic Power Unit in well-ventilated areas only. DO NOT operate hydraulic power unit in combustible atmospheres. Remove flammable materials from work area. Operate only within temperature range of 20 C to 40 C (-4 F to 04 F) Bolt Tightening Torque Bolt Size #0-32 ¼-20 5/6-8 3/8-6 Torque 38 in. lbs. 76 in. lbs. 3 ft. lbs. 23 ft. lbs
25 Graphic Set Complete ( D) P/N 859-OD 859-O2D 859-O7D 859-O8D 978-O2D D 3888-OOD 3889-OD D 2849-OD 2849-O2D 2906-OOD DESCRIPTION CAUTION FAN HYDRAULIC OIL PRESSURE RETURN FLUID LEVEL ON/OFF KNOB DECAL SERIAL NUMBER DECAL CLEAR COAT MADE IN USA G-O5 LEFT SIDE G-05 RIGHT SIDE PortaCo DECAL QTY The 3888-OOD serial number decal is not included in graphic set for parts order. It can only be replaced by the factory.
26 SERVICE AND REPAIR NOTES
Hydraulic Power Unit Pioneer Series G-09, G-11, G-13
Hydraulic Power Unit Pioneer Series G-09, G-11, G-13 OPERATION, MAINTENANCE, AND REPAIR MANUAL 1805 2 nd AVENUE NORTH * MOORHEAD, MN, USA 56560-2310 PHONE (218) 236-0223 * FAX (218) 233-5281 E-MAIL ADDRESS;
More informationHydraulic Power Unit Pioneer Series G-09, G-11, G-13
Hydraulic Power Unit Pioneer Series G-09, G-11, G-13 OPERATION, MAINTENANCE, AND REPAIR MANUAL Original Instructions 2015 1805 2 nd AVENUE NORTH * MOORHEAD, MN, USA 56560-2310 PHONE (218) 236-0223 * FAX
More informationHydraulic Power Unit Prowler Series D-19
Hydraulic Power Unit Prowler Series D-19 OPERATION, MAINTENANCE, AND REPAIR MANUAL 1805 2 nd AVENUE NORTH * MOORHEAD, MN, USA 56560-2310 PHONE (218) 236-0223 * FAX (218) 233-5281 E-MAIL ADDRESS; info@portaco.com
More informationMODEL WS WELD SHEAR OPERATION, MAINTENANCE, AND REPAIR MANUAL
MODEL WS-10-64-3 WELD SHEAR OPERATION, MAINTENANCE, AND REPAIR MANUAL 1805 2 nd AVENUE NORTH * MOORHEAD, MN, USA 56560-2310 PHONE (218) 236-0223 * FAX (218) 233-5281 E-MAIL ADDRESS; info@portaco.com *
More informationMODEL WS WELD SHEAR HAND PUMP OPERATION, MAINTENANCE, AND REPAIR MANUAL
MODEL WS-00-60- WELD SHEAR HAND PUMP OPERATION, MAINTENANCE, AND REPAIR MANUAL 805 nd AVENUE NORTH * MOORHEAD, MN, USA 56560-30 PHONE (8) 36-03 * FAX (8) 33-58 E-MAIL ADDRESS; info@portaco.com * INTERNET
More informationLR O Safeloc Clip Remover MAINTENANCE MANUAL
LR-05-81-O Safeloc Clip Remover MAINTENANCE MANUAL 1 TABLE OF CONTENTS 1.0 Introduction 1.1 General Information 1.2 Features 1.3 Options 1.4 Safety Summary 1.5 General Safety Precautions 1.6 Warning and
More informationMODEL GH GRINDER STRAIGHT HANDLE OPERATION, MAINTENANCE, AND REPAIR MANUAL
MODEL GH-10-28-0 GRINDER STRAIGHT HANDLE OPERATION, MAINTENANCE, AND REPAIR MANUAL 1805 2 nd AVENUE NORTH * MOORHEAD, MN, USA 56560-2310 PHONE (218) 236-0223 * FAX (218) 233-5281 E-MAIL ADDRESS; info@portaco.com
More informationMODEL DL-10-B1-O LAG DRIVER OPERATION AND MAINTENANCE MANUAL
MODEL DL-10-B1-O LAG DRIVER OPERATION AND MAINTENANCE MANUAL 1 Warranty: PortaCo, Inc. warrants, to the original purchaser all products manufactured by it to be free from defects, in material and workmanship
More informationMODEL DT-10-H3-O 3/4 TIE DRILL OPERATION AND MAINTENANCE MANUAL
MODEL DT-10-H3-O 3/4 TIE DRILL OPERATION AND MAINTENANCE MANUAL 1 Warranty: PortaCo, Inc. warrants, to the original purchaser all products manufactured by it to be free from defects, in material and workmanship
More informationMODEL CF-00-F3-O GAS FLANGE WAY CLEANER OPERATION, MAINTENANCE, AND REPAIR MANUAL
MODEL CF-00-F3-O GAS FLANGE WAY CLEANER OPERATION, MAINTENANCE, AND REPAIR MANUAL 1805 2 nd AVENUE NORTH * MOORHEAD, MN, USA 56560-2310 1 PHONE (218) 236-0223 * FAX (218) 233-5281 E-MAIL ADDRESS; info@portaco.com
More informationMODEL DT-10-H3-O 3/4 TIE DRILL OPERATION AND MAINTENANCE MANUAL
MODEL DT-10-H3-O 3/4 TIE DRILL OPERATION AND MAINTENANCE MANUAL 1 Warranty: PortaCo, Inc. warrants, to the original purchaser all products manufactured by it to be free from defects, in material and workmanship
More informationPortable Hydraulic Power Pack
USER'S GUIDE & SAFETY MANUAL USER'S GUIDE & SAFETY MANUAL Portable Hydraulic Power Pack Important Safety Notice Read and understand these usage and safety instructions before using a Condux Portable Hydraulic
More informationMODEL D-25S12-22-S POWER UNIT OPERATION, MAINTENANCE, AND REPAIR MANUAL
MODEL D-25S12-22-S POWER UNIT OPERATION, MAINTENANCE, AND REPAIR MANUAL Introduction 1805 2 nd AVENUE NORTH * MOORHEAD, MN, USA 56560-2310 PHONE (218) 236-0223 * FAX (218) 233-5281 E-MAIL ADDRESS; info@portaco.com
More informationMODEL D-100D1540-G9-O POWER UNIT OPERATION, MAINTENANCE, AND REPAIR MANUAL
MODEL D-00D50-G9-O POWER UNIT OPERATION, MAINTENANCE, AND REPAIR MANUAL 805 nd AVENUE NORTH * MOORHEAD, MN, USA 56560-30 PHONE (8) 36-03 * FAX (8) 33-58 E-MAIL ADDRESS; info@portaco.com * INTERNET ADDRESS:
More informationP110 HYDRAULIC POWER UNIT USER S MANUAL SAFETY, OPERATION AND MAINTENANCE
P110 HYDRAULIC POWER UNIT USER S MANUAL SAFETY, OPERATION AND MAINTENANCE 2017 ICS Blount Inc. 4909 SE International Way Portland, OR 97222 81117 9/2017 Ver. 1 NOTES 2 P110 User Manual 800.321.1240 icsdiamondtools.com
More informationHP12 HYDRAULIC POWER UNIT
HP HYDRAULIC POWER UNIT (HPB) USER S MANUAL SAFETY, OPERATION AND MAINTENANCE 07 STANLEY Black & Decker, Inc. New Britain, CT 06053 U.S.A. 87 /07 Ver. TABLE OF CONTENTS SAFETY SYMBOLS... SAFETY PRECAUTIONS...5
More informationGT23 HYDRAULIC POWER UNIT
GT23 HYDRAULIC POWER UNIT SAFETY, OPERATION AND MAINTENANCE USER S MANUAL 2011 Stanley Black & Decker, Inc. New Britain, CT 06053 U.S.A. 69405 5/2013 Ver. 5 1 NOTES 2 TABLE OF CONTENTS SAFETY SYMBOLS...
More informationAG-HA-2500N GASOLINE GENERATOR
AG-HA-2500N GASOLINE GENERATOR OWNER S MANUAL BEFORE OPERATING THIS EQUIPMENT PLEASE READ THESE INSTRUCTIONS CAREFULLY (I)WARNING 1. Read the operator s instruction manual. 2. Attention! Exhaust gases
More informationP110 HYDRAULIC POWER UNIT
P110 HYDRAULIC POWER UNIT Safety, Operation and Maintenance USER MANUAL Copyright 2012, ICS Blount, Inc. ICS Blount, Inc. 4909 SE International Way Portland, Oregon 97222 www.icsdiamondtools.com NOTES
More informationGT23 HYDRAULIC POWER UNIT USER S MANUAL SAFETY, OPERATION AND MAINTENANCE
GT23 HYDRAULIC POWER UNIT USER S MANUAL SAFETY, OPERATION AND MAINTENANCE 2014 STANLEY Black & Decker, Inc. New Britain, CT 06053 U.S.A. 69405 1/2018 Ver. 12 TABLE OF CONTENTS SAFETY SYMBOLS...4 SAFETY
More informationTWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air
ORIGINAL INSTRUCTIONS Form No.1000458 5 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 Internet
More informationPORTABLE TRASH PUMPS MTP200 MTP300 MTP400
PORTABLE TRASH PUMPS MTP200 MTP300 MTP400 OPERATING & PARTS MANUAL INTRODUCTION This manual provides information and procedures to safely operate and maintain the engine and pump. For your own safety and
More informationPORTABLE TRASH PUMPS MDP200
PORTABLE TRASH PUMPS MDP200 OPERATING & PARTS MANUAL INTRODUCTION This manual provides information and procedures to safely operate and maintain the engine and pump. For your own safety and protection
More informationHP18289M HYDRAULIC DIESEL POWER UNIT SAFETY, OPERATION AND MAINTENANCE SERVICE MANUAL WARNING
HP18289M HYDRAULIC DIESEL POWER UNIT WARNING To avoid serious injury or death Read the Manual Wear Ear Protection Wear Eye Protection Wear Dust Mask 47351 Copyright 2003, The Stanley Works OPS/SVCE USA
More informationHP1. COMPACT POWER UNIT Safety, Operation and Maintenance Manual SERIOUS INJURY OR DEATH OF THIS TOOL.
HP1 COMPACT POWER UNIT Safety, Operation and Maintenance Manual SERIOUS INJURY OR DEATH COULD RESULT FROM THE IMPROPER REPAIR OR SERVICE OF THIS TOOL. REPAIRS AND / OR SERVICE TO THIS TOOL MUST ONLY BE
More informationGTR20 HYDRAULIC POWER UNIT. Safety, Operation and Maintenance Stanley Black & Decker, Inc. New Britain, CT U.S.A /2013 Ver.
GTR20 HYDRAULIC POWER UNIT Safety, Operation and Maintenance USER MANUAL 2011 Stanley Black & Decker, Inc. New Britain, CT 06053 U.S.A. 65114 5/2013 Ver. 9 NOTES 2 GTR20 User Manual TABLE OF CONTENTS SAFETY
More informationHydraulic Immediate Need Power Pack
Safety, Operation, and Maintenance Manual WARNING Improper use of this tool can result in serious bodily injury This manual contains important information about product function and safety. Please read
More informationAIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST
AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST BELT TYPE IMPORTANT PLEASE MAKE CERTAIN THAT THE PERSON WHO IS TO USE THIS EQUIPMENT CAREFULLY READS AND UNDERSTANDS THESE INSTRUCTIONS BEFORE STARTING
More informationTP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL
TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL IT IS EXTREMELY IMPORTANT TO READ AND UNDERSTAND THE ENTIRE CONTENTS OF THIS OPERATOR S MANUAL BEFORE ATTEMPTING TO OPERATE THE PRODUCT. THIS EQUIPMENT IS
More informationOwner s/operator s Manual
Water Pump MP2533E2 Owner s/operator s Manual Completely read and understand this manual before using this product. Foreword This Owner s/ Operator s Manual is designed to familiarize the operator with
More informationTrench Filler for Compact Utility Loaders
Form No. 3353-608 Rev A Trench Filler for Compact Utility Loaders Model No. 22472 260000001 and Up Operator s Manual Register your product at www.toro.com Original Instructions (EN) Contents Page Introduction................................
More informationAir / Hydraulic Pump
Form No. 538016 Parts List & Operating Instructions for: 2510A Original Instructions Air / Hydraulic Pump Maximum Capacity: 690 bar (10,000 psi) Description: The 2510A air/hydraulic pump is designed to
More informationThis unit has been used for many years to power the TapMate Too (351-00) with the hydraulic drive head attachment ( ).
Transmate 3 HP Honda Hydraulic Power Drive 372-351-01 Thank you for purchasing the Transmate 3 HP HONDA Hydraulic Power Unit. This unit will give you years of service if the simple instructions below are
More informationKING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.
KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC. WARRANTY & SERVICE INFORMATION 1-YEAR LIMITED WARRANTY FOR THIS 950W
More informationRedGum GP160 Splitter. Owner s Manual
RedGum GP160 Splitter Owner s Manual Product Description & Intended Purpose: This Log Splitter / Wood Splitter is an outdoor product that splits wood logs for use as fuel in a fireplace or a woodstove.
More informationOWNER'S MANUAL WARNING DANGER. Propane cylinders sold separately. The propane cylinder must be disconnected when this firebowl is not use.
OWNER'S MANUAL READ BEFORE USE! Model No.: BH5003-3 Style No.: 66646 For Outdoor Use Only! Use Propane Gas Only! Propane cylinders sold separately. USE PROPANE GAS ONLY! -Do not store or use gasoline or
More informationHUSTLER TURF EQUIPMENT GENERAL SERVICE INFORMATION DAILY SERVICE & PREVENTIVE MAINTENANCE HUSTLER MINI FASTRAK MODEL # , , ,
General Service Information 1 HUSTLER TURF EQUIPMENT GENERAL SERVICE INFORMATION DAILY SERVICE & PREVENTIVE MAINTENANCE HUSTLER MINI FASTRAK MODEL # 927343, 927350, 927376, 927368 GENERAL ENGINE SPECIFICATION
More informationWCI-20 Power-Pak Coldwork Hydraulic Power Supply Rev B
WCI-20 Power-Pak Coldwork Hydraulic Power Supply Rev B OM-PS-9303-2 Seattle, Washington WCI-20 Power Pak Manual Table of Contents Section 1 Introduction 1.1 Introduction... 1 1.2 Safety Precautions...
More informationPOWER PACK W/OIL COOLER P/N 32800
POWER PACK W/OIL COOLER P/N 32800 OPERATION AND MAINTENANCE MANUAL Copyright 2017 by All rights reserved. No part of this publication may be copied, reproduced or transmitted in any form whatsoever without
More informationAir / Hydraulic Pump Instructions. CAUTION: Read and Understand These Operating, Servicing, and Safety Instructions, Before Using This Machine.
Air / Hydraulic Pump Instructions CAUTION: Read and Understand These Operating, Servicing, and Safety Instructions, Before Using This Machine. 1-800-467-2464 10 Cooperative Way Wright City, MO 63390 P.O.
More information1200W INVERTER GENERATOR
1200W INVERTER GENERATOR MODEL NO: IG1200 PART NO: 8877070 OPERATION & MAINTENANCE INSTRUCTIONS LS0117 INTRODUCTION Thank you for purchasing this CLARKE 1200W Inverter Generator. Before attempting to use
More informationGTR20 HYDRAULIC POWER UNIT
GTR20 HYDRAULIC POWER UNIT USER MANUAL Safety, Operation and Maintenance 2014 Stanley Black & Decker, Inc. New Britain, CT 06053 U.S.A. 65114 7/2017 Ver. 18 2 GTR20 User Manual NOTES TABLE OF CONTENTS
More informationAIR PAINT SHAKER OWNER'S MANUAL
AIR PAINT SHAKER OWNER'S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal
More informationLAWN MOWER OWNER S MANUAL
LAWN MOWER OWNER S MANUAL Woodies SKU: 1153279 & 1153280 CAUTION: Read and follow all Safety Rules and Instructions before operating this equipment Thank you for choosing our Gasoline Lawnmower. 1 To ensure
More informationWARNING! Ensure that there are no naked flames around the product! Do not smoke while filling fuel and oil!
Engine Oil and Fuel Engine Operation This product is equipped with a 4 stroke engine. Before operation you have to add proper fuel and engine oil. DO NOT MIXTURE THEM! 1. Place the product on a stable,
More information1100W PORTABLE GENERATOR
1100W PORTABLE GENERATOR MODEL NO: G1200 PART NO: 8010110 OPERATION & MAINTENANCE INSTRUCTIONS LS0312 INTRODUCTION Thank you for purchasing this CLARKE 1100W Portable Generator. Before attempting to use
More informationGENERAL ENGINE SPECIFICATIONS
General Service Information 1 HUSTLER TURF EQUIPMENT GENERAL SERVICE INFORMATION DAILY SERVICE & PREVENTIVE MAINTENANCE HUSTLER FASTRAK MODEL # 926501, 926519, 926592, 926527, 926600, 926774, 927442, 927459
More informationOperating, Servicing, and Safety Manual Model # Hydraulic Bender
Operating, Servicing, and Safety Manual Model # 900 90 Hydraulic Bender CAUTION: Read and Understand These Operating, Servicing, and Safety Instructions, Before Using This Machine. 1-800-467-2464 10 Cooperative
More informationMANUAL FLUID EXTRACTOR
Please read and save these instructions. Read through this owner s manual carefully before using product. Protect yourself and others by observing all safety information, warnings, and cautions. Failure
More informationVoltmaster Centrifugal Trash Pumps
Voltmaster Centrifugal Trash Pumps Model TSP2, TSP3 and TSP4 Owner s Manual February 2011 Table of Contents 1 Introduction............................ 1 1.1 Read before using..................... 1 1.2
More informationPost Driver Attachment
Attachment (Shown with Optional Power Cell Rotator) Models - 600, 850 Safety Instructions This safety alert symbol indicates important safety messages in this manual. When you see this symbol, carefully
More informationAIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS
I. OPERATION & DESCRIPTION The Air / Hydraulic Injection Gun is a high-pressure tool that should be used with caution and according to these instructions. IMPORTANT: The Gun is 0,000 psi rated. Do not
More informationTrencher Dingo Attachment
Form No. 3326-453 Trencher Dingo Attachment Model No. 22459 2000000 & Up Operator s Manual English (CE) Contents Page Introduction................................ 2 Safety.....................................
More information6 HP KOLHER HYDRAULIC POWER UNIT - Rev. 5 10/17/2008
ROMAC INDUSTRIES, INC. 21919 20th Avenue SE Suite 100 Bothell, WA 90821 1 800 426 9341 www.romacindustries.com Transmate 6 HP KOLHER HYDRAULIC POWER UNIT - Rev. 5 10/17/2008 Thank you for purchasing the
More informationEclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions
Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions Read Read through the the safety installation information instructions overhaul carefully instructions before carefully beginning
More informationSingle and Double Head Powered Screed. Screed King. User Manual. SCR-UM EN-04 (December 2018)
Single and Double Head Powered Screed Screed King SCR-UM-00364-EN-04 () User Manual Single and Double Head Powered Screed, Screed King CONTENTS Scope of This Manual.............................................
More informationEclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions
Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions Read Read through the the safety installation information instructions overhaul carefully instructions
More information5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616
5.5KVA GENERATOR MODEL NO: PG6500DVES PART NO: 8857810 OPERATION & MAINTENANCE INSTRUCTIONS LS0616 INTRODUCTION Thank you for purchasing this CLARKE 5.5KVA Generator. Before attempting to use this product,
More informationCAUTION. Start & Stop Procedures. Section 1-2. Engine Oil Level
Section 1-2 Start & Stop Procedures Before operating this machine, the operator must have: received operator training, a familiarity with this manual, and a complete understanding of all the procedures
More information50 Gallon Skid Sprayer
50 Gallon Skid Sprayer Model #: KS50P5 User Manual Read this manual for complete instructions Model #: KS50P5 Table of Contents Warranty... 3 General Safety Information... 3 Hazardous Substance Alert...
More informationCAUTION. Start & Stop Procedures. Section 4-2. Engine Oil Level
Section 4-2 Start & Stop Procedures Before operating this machine, the operator must have: received operator training, a familiarity with this manual, and a complete understanding of all the procedures
More informationOperation and Maintenance Manual http://www.torsionx.eu Use the MaxDrv Series Square Drive Torque Wrench Model.75, 1, 3, 5, 8, 10, 20, 25, 35, 50 to install and remove threaded fasteners requiring precise
More informationHydraulic PTO Flow Device
Safety, Operation, and Maintenance Manual WARNING Improper use of this tool can result in serious bodily injury This manual contains important information about product function and safety. Please read
More informationOWNER S MANUAL MODEL TTP-300 3X3 Commercial Trash Pump
OWNER S MANUAL MODEL TTP-300 3X3 Commercial Trash Pump P. O.Box 791, Travelers Rest, S.C. 29690 Phone 864-834-7212 Service/Replacement Parts 800-845-4141 WWW.TITANINDUSTRIAL.NET WARNING! Do Not Operate
More informationOperating instructions Form no safety definitions
Operating instructions Form no. 1000437 safety definitions safety symbols are used to identify any action or lack of action that can cause personal injury. Your reading and understanding of these safety
More informationGENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609
GENERATOR MODEL NO: FG3000 PART NO: 8857700 OPERATION & MAINTENANCE INSTRUCTIONS LS0609 INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to use this product, please read this
More informationLP DEL PAC. ATLAS COPCO CONSTRUCTION TOOLS AB NACKA SWEDEN No
LP 13-20 DEL PAC ATLAS COPCO CONSTRUCTION TOOLS AB 2007-03 NACKA SWEDEN No. 3392 5146 01 www.atlascopco.com 1 English!"!" INTRODUCTION... 2 SAFETY INSTRUCTIONS... 2 Introduction to safety... 2 Safety symbols
More informationGENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413
GENERATOR MODEL NO: FG3005 PART NO: 8857707 OPERATION & MAINTENANCE INSTRUCTIONS LS0413 INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to use this product, please read this
More informationASSEMBLY and OPERATING INSTRUCTIONS Mission Oaks Blvd. / Camarillo, CA 93011
SPARK PLUG CLEANER ASSEMBLY and OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd. / Camarillo, CA 93011 Copyright 1997 by Harbor Freight Tools. All rights reserved. No portion of this manual or any artwork
More informationSERIES OPERATION AND MAINTENANCE MANUAL
SERIES OPERATION AND MAINTENANCE MANUAL This manual CONTAINS IMPORTANT WARNINGS, S and OTHER INSTRUCTIONS. Read and understand the instruction manual Carefully, before use and retain it for reference.
More informationDIRECT-DRIVE PRESSURE WASHERS
DIRECT-DRIVE PRESSURE WASHERS PJG SERIES PRESSURE WASHER MANUFACTURED BY: PJG-2001 PJG-2501-6.5 PJG-2501 PJG-3000 PJG-3001 PJG-3501 PJG-4001 OPERATOR s INTRODUCTION Thank you for purchasing a Mancorp Pressure
More informationDIRECT-DRIVE PRESSURE WASHERS
DIRECT-DRIVE PRESSURE WASHERS PJG SERIES PRESSURE WASHER MANUFACTURED BY: PJG-2002B PJG-2502-6.5B PJG-3002B PJG-4002B INTRODUCTION Thank you for purchasing a Mancorp Pressure Washer. This manual covers
More information3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV
3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV PART NO: 8857815 OPERATION & MAINTENANCE INSTRUCTIONS LS1016 INTRODUCTION Thank you for purchasing this CLARKE 3KVA Dual Voltage Generator. Before attempting
More informationCAPACITIES AND SPECIFICATIONS
CAPACITIES AND SPECIFICATIONS W40Z [B218]; W45Z [C215]; W50Z [D215] PART NO. 1499833 8000 SRM 1010 SAFETY PRECAUTIONS MAINTENANCE AND REPAIR When lifting parts or assemblies, make sure all slings, chains,
More informationP95 HYDRAULIC POWER UNIT. Safety, Operation and Maintenance. ICS Blount, Inc SE International Way Portland, Oregon
P95 HYDRAULIC POWER UNIT Safety, Operation and Maintenance USER MANUAL Copyright 2012, ICS Blount, Inc. ICS Blount, Inc. 4909 SE International Way Portland, Oregon 97222 www.icsdiamondtools.com DECLARATION
More informationIBT Series Square Drive Torque Wrenches
IBT Series Square Drive Torque Wrenches Operation and Maintenance Manual Model.75, 1, 3, 5, 8, 10, 20, 25, 35, 50 http://www.torsionx.com Use the IBT Series Square Drive Torque Wrenches Model.75, 1, 3,
More information3. INSPECTION/ADJUSTMENT
3 3 INSPECTION/ADJUSTMENT SERVICE INFORMATION-------------------------------------------------- 3-1 MAINTENANCE SCHEDULE---------------------------------------------- 3-3 FUEL LINE---------------------------------------------------------------------
More informationbefore serial number 2214
before serial number 2214 Contents Page Safety Rules... 3 Pre-operational & Safety Inspection... 4 Operating Instructions... 6 Transport... 12 Maintenance & Routine Service... 12 Specifications... 14 SAFETY
More informationABSOLUTE EQUIPMENT PTY LTD
Manual Hydraulic Toe Jack Model DTJ Series ABSOLUTE EQUIPMENT PTY LTD 2/186 Granite Street, GEEBUNG QLD 4034 Australia sales@absoluteequipment.com.au Phone: +61 7 3865 4006 Fax: +61 7 3102 6288 This is
More informationHexPro Series Low Profile Wrenches
HexPro Series Low Profile Wrenches Operation and Maintenance Manual Model 2HP 4HP 8HP 14HP 30HP www.torquetoolsinc.com Use the HEXPRO Series Low Profile Wrenches Model 2HP 4HP 8HP 14HP 30HP to install
More informationSECTION 6 2 SERVICE PROCEDURES AND SPECIFICATIONS. Engine. Specifications
SERVICE PROCEDURES AND SPECIFICATIONS Engine SECTION 6 2 Specifications........................................... 162 Fuel.................................................... 164 Facts about engine oil
More informationViscount I Hydraulic Motor and Displacement Pump
INSTRUCTIONS-PARTS LIST 308 674 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. C Supersedes Rev. B Viscount I Hydraulic Motor and Displacement Pump
More informationCommercial Series Generator Operator Manual (with Kohler Command series engines)
Commercial Series Generator Operator Manual (with Kohler Command series engines) PN: 220880 PREFACE Thank you for purchasing a Wanco Commercial Series portable generator set. This manual contains important
More informationABSOLUTE EQUIPMENT PTY LTD
Manual Hydraulic Toe Jack Model DTJ Series ABSOLUTE EQUIPMENT PTY LTD 2/186 Granite Street, GEEBUNG QLD 4034 Australia sales@absoluteequipment.com.au Phone: +61 7 3865 4006 Fax: +61 7 3102 6288 This is
More informationMODEL 25-OM-10-C & 25-OA-10-C HYDRAULIC BOOSTER
SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.powerteam.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031
More information#9040 FUEL TANK SWEEPER
#9040 FUEL TANK SWEEPER INSTRUCTION MANUAL FILTERS AND REMOVES FINE BIO-CONTAMINANTS, ALGAE, ETC. SWEEPING PROCESS REMOVES LARGE CONTAMINANTS FROM OIL TANKS SUCH AS RUST, WATER, CRUDE AND DIRT CIRCULATES
More informationWA 2719 ( 604 ) ( 604 ) , H.E.R.O.
a division of Middlefield Bancorp Limited 2719 Lake City Way, Burnaby, B.C., Canada Phone: ( 604 ) 420-6543 Fax: ( 604 ) 420-8725 Toll Free: 1-800-494-4376 E-mail: sales@hero.ca Website: www.hero.ca U.S.
More informationRead instructions carefully and follow rules for safe operation. Failure to do so could result in serious injury. Fradan Manufacturing Corp.
OPERATOR MANUAL FRADAN POWER BLOWERS Part No. 888-011-222-0 Read instructions carefully and follow rules for safe operation. Failure to do so could result in serious injury. Fradan Manufacturing Corp.
More informationInstruction Manual. Maximum Operating Pressure 700 bar
Remote Hydraulic Cutter Model HC-120R Maximum Operating Pressure 700 bar ABSOLUTE EQUIPMENT PTY LTD 2/186 Granite Street, GEEBUNG QLD 4034 Australia sales@absoluteequipment.com.au Phone: +61 7 3865 4006
More informationSIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions
SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.
More informationAir-Operated Waste Oil Drainer
Air-Operated Waste Oil Drainer 20-Gallon Tank Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other
More informationOwner s Information Manual
50ES---A and 50VL---C Comfort 13SEERThreePhase2½---5NominalTons (Sizes 30---60) Comfort 14 SEER Single and Three Phase 2---5 Nominal Tons (Sizes 24---60) Single Packaged Air Conditioner System With Puronr
More information1-1/2 DIAMETER WATER PUMP
1-1/2 DIAMETER WATER PUMP 2.2HP/79.8cc Engine MODEL # 101099 Operation Manual This safety alert symbol identifies important safety messages in this manual. Failure to follow this important safety information
More informationLow Profile Wrenches Operation and Maintenance Manual
Low Profile Wrenches Operation and Maintenance Manual http://www.torquetoolsinc.com Use the HEXPRO Series Low Profile Wrenches Model 2HP 4HP 8HP 14HP 30HP to install and remove large bolts that have minimal
More informationBT-1.5, BT-1.5-LP (NITRO) POWER UNIT Operations Manual
BT-1.5, BT-1.5-LP (NITRO) POWER UNIT Operations Manual BT-1.5 BT-1.5-LP TNT Rescue Systems, Inc. 2490 West Oak Street Ashippun, WI 53003 920-474-4101 or 800-474-4189 E-Mail: email@tntrescue.com! WARNING!
More informationHOFFMANN POWER PRODUCTS PARTS LIST 2014
HOFFMANN POWER PRODUCTS PARTS LIST 2014 VIBRATORY PLATE COMPACTOR ALL PARTS ARE SUBJECT TO STANDARD HOFFMANN TERMS AND CONDITIONS OF SALE 2010 Replacement parts are not manufactured, sold or warranted
More informationGRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN
REPAIR J Line Driver Model 233725 U.S. Patent Number 6,883,633 Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. 10 mph (16 kph) Maximum Operating
More informationOPERATOR S MANUAL Model 60010
OPERATOR S MANUAL Model 60010 10- TON SNAP LOCK PORTA POWER SET W/ WHEELED CASE PROFESSIONAL HYDRAULIC JACKS 1531 W. Mohawk Drive Phone 715-453-9602 Customer Service 800-995-2250 Tomahawk, WI 54487 Fax
More informationOperating Instructions - Electric Pow'r-Riser Models
ADivisionOf Templeton, Kenly& Co., Inc. Operating Instructions - Electric Pow'r-Riser Models Table of Contents 1.0 Recieving Instructions 2.0 Safety 3.0 Specifications 4.0 Initial Installation Before Operating
More informationRUFNEX Series Low Profile Wrenches Operation and Maintenance Manual
RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual http://www.torsionx.com Use the RUFNEX Series Ultra-Low Profile Wrenches to install and remove large bolts that have minimal wrench clearance.
More information