1 MANSON ENGINEERING INDUSTRIAL LTD. SERVICE MANUAL FOR SPS-9400
2 CONTENTS 1. PRODUCTION SPECIFICATION P.1 2. ALIGNMENT PROCEDURE P.2 3. TROUBLE SHOOTING P.5 4. DIAGRAMS P SCHEMATICS P PCB SILKSCREEN P.7 5. BILL OF MATERIAL P.8
3 1. PRODUCTION SPECIFICATION MODEL: SPS REV. 1.0 DATE: DESCRIPTION: 3-15V 40A SWITCHING MODE POWER SUPPLY INPUT VOLTAGE: VAC FREQUENCY: 50 Hz ENVIRONMENT TEMPERATURE: 25 0 C MIN. TYP. MAX. UNIT Rated Output Voltage Range 3 15 V Max. Output Voltage V Min. Output Voltage 3 V Fixed Output Voltage V Output Current (continue) 40 A Protection Current (start point) A Over Voltage Protection V Voltage Regulation: Load (0~100% load) 200 mv Line (207~254Vac Varition) 50 mv Ripple & Noise (r.m.s) 2 5 mv Ripple & Noise (peak to peak) mv No Load Input Current 380 ma Full Load Input Current 3.5 A Power consumption at 15V 770 W Insulation Resistance (500Vdc) 100 MΩ Withstanding Test (10mA 60s) 2.1 KV Power factor 97 % Efficiency: Loading 13.8V 40A % Loading 15V 40A % Meter Accuracy: Voltmeter ±1+1 Dight Ammeter ±1+1 Dight Fuse 5 A REMARKS: 1. Rated load is 15V 40A. 2. Insulation resistance is measured as INPUT vs. HOUSING. 3. High frequency interference test (sample 3%). Test frequency : MHz (5W) MHz (5W) Result : No function have been affected. Output Voltage 0.5V Variation.
4 2. ALIGNMENT PROCEDURE Equipment Quantity CRO 1 Digital Multimeter 1 High Frequency Micrometer 1 Electronic Load 1 Adjustable AC Transformer 1 Power Analyzer 1 DC Regulated Power Supply (Max. V>17) 1 Procedures: 1. No Load Input Current Measurement Switch ON the SPS-9400, the Power Indicator Should light up in green, the fan rotates in a low speed. The SPS-9400 Ammeter should display 00.0, the Voltmeter should not display 00.0, the Power Analyzer should display a current of less than 380mA. 2. Voltmeter Adjustment Switch SW2 located at the bottom side of the unit to position FIXED, connect a Digital Multimeter to the output terminal of SPS-9400, adjust RV4 such that the Digital Multimeter display a voltage of ~ 13.84V. Turning the control knob on the front panel will make no change to the output voltage. Switch SW2 to another position, turn the control knob on the front panel to fully-clockwise position, adjust RV2 such that the Digital Multimeter display 15.4 ~ 15.6V, then turn the control knob to fully-counterclockwise position, the Digital Multimeter should display a voltage of less than 3V. 3. Protection Current Adjustment Adjust the output voltage of SPS-9400 to 15V by turning the control knob, turn RV3 to fully-clockwise position, connect the Electronic Load, slowly adjust the loading current to 44.5A. Then, slowly turn RV3 in counter-clockwise until the overload red LED indicator lights up and the output voltage falls suddenly. Afterward, decreases the loading current to 0A, the red light should OFF and the output voltage returns to normal condition. Then, slowly increases the loading current, when the loading current is 43 ~ 44.5A, the overload red LED indicator will light up and the output voltage will fall.
5 4. Power Consumption Test Adjust the output voltage of SPS-9400 to 15V and connect the electronic load with 40A loading current, the Power Analyzer should display an input current of less than 3.5A, power factor of more than 0.97 and input power of less than 770W. 5. Voltmeter Calibration Adjust the output voltage of SPS-9400 to 15.0V, connect the Digital Multimeter to the output terminal of SPS-9400, adjust the variable resistor on the Voltmeter such that the voltage display on the Digital Multimeter is equal to the voltage display on Voltmeter. Then, check that the voltage on the Voltmeter increases as the control knob is turned in clockwise direction. Similarly, check that the voltage decreases as the control knob is turned in counterclockwise direction. Also, the difference between the voltage on Voltmeter and the Digital Multimeter should less than 0.2V. And check that the LED Voltmeter does not have missing segment. 6. Ammeter Calibration Connect the Electronic Load with 40A loading current, adjust the variable resistor of Ammeter such that the Ammeter displays Then, check that the current on Ammeter increases as the loading current on the Electronic Load increases. Similarly, check that the current on Ammeter decreases as the loading current on the Electronic Load decreases. Also, the difference between the current on Ammeter and the Digital Multimeter should less than 0.4A. And check that the LED Ammeter does not have missing segment. 7. Over-Voltage Protection Test Adjust the output voltage of the DC Regulated Power Supply to 15.9V and connect to the output terminal of SPS-9400, then disconnect it and the SPS-9400 is in working condition. Adjust the output voltage of the DC Regulated Power Supply to 16.9V and connect to the output terminal SPS-9400, then disconnect it. The overload red LED indicator of SPS-9400 will light up and the output voltage will fall. 8. Load Regulation Measurement Adjust the output voltage of SPS-9400 to 15V and connect to the Electronic Load with 40A loading current, measure the output voltage by the Digital Multimeter and record the voltage. Then, disconnect from the load and measure the output voltage again. The difference between 2 voltages should less than 200mV.
6 9. Ripple and Noise Measurement Adjust the output voltage of SPS-9400 to 15V and connect to the Electronic Load with 40A loading current. Measure the output terminal by the High Frequency Micrometer and the value should less than 5mV. Connect the output terminal to CRO and the Peak to Peak measured wave form should less than 50mVp-p. 10. Line Regulation Measurement Adjust the output voltage of SPS-9400 to 15V and connect to the Electronic Load with 40A loading current. Adjust the input voltage to 190V and 254V, record the output voltage at these 2 input voltages, the difference between these 2 output voltages should less than 50mV. 11. Loading Test Adjust the output voltage of SPS-9400 to 15V and connect to the Electronic Load with 40A loading current, turn OFF the SPS Then, make sure the Electronic Load has a 40A loading current, turn ON SPS-9400 again and check that the SPS-9400 is ON and the Overload Indicator is OFF. Remarks: 1. The above procedures should be carried out in normal condition, if the SPS-9400 has abnormal condition (e.g. Unpleasant noise, smell, smoke, etc...), turns OFF the AC source at once.
7 3. Trouble Shooting 1. The Power Supply do not turn ON. a. Switch off the unit. b. Check the fuse if it is blown, replace with the same type of the fuse. c. Check the AC Power Cord is firmly plugged into the AC socket of the Power Supply. d. Switch on the unit again if problem persists. 2. Overload LED Indicator light up once the unit is turned ON. a. Check if the loading current is not more than 40A, adjust the loading current of not more than 40A b. Check if the output voltage is not more than 16.5V. The Over Voltage Protection is at 16.5V. c. Check if the output is short circuit. d. Switch off the unit, wait 30 minutes and switch it ON again to see if problem persists.
8 DM VDD - OUTPUT<+> OUTPUT<-> OUTPUT<+> D C B A AC FILTER OUTPUT R18 3.9K C18 R28 2K RV2 5K INPUT SW1 12A RV1 R44 R5 K SW1 12A VAC 50HZ C1 1UF/275VAC R19 R20 C19 R R L2 100UH L3 100UH R29 1.8K S2 R001 39K R35 1M ZD3 13V/ 1W U4F C27 1UF 50V OUTPUT<+> OUT1 5 6 R21 56K L1 6.0MH R25 1M R36 4.7K Over Voltage Protetion F1 5A RV4 1K OUTPUT"+" MOV R30 R45 4.7K D11 R31 220K 8 C2 /275VAC U3B 7 C LM324 U4D 1 2 R32 1K C U4E R K R U4A 9 AC LINE FILTER C PF R C PF R37 33K D8 BR1 10G4B R26 22K R23 1.5K C22 R27 100K R33 4.7K R38 330K Q4 C1815 Q5 C LED1 RED C C C PF R K R43 3K 8 9 D12 C32 NTC1 C79 20S100L 1UF 275VAC C3 3.3/400V C /250VAC R46 47K R K C5 3.3/400V R40 56k U5 TL494 C33 C80 UF 275VAC L7 0.7MH C6 R24 1.5K LED2 GREEN U4C 5 6 C24 C25 C23 C31 1UF R R1 1.3M R47 1K R2 12K C7 1UF/50V R3 100K/1W 8 U1 MC34262 R D9 RV3 5K R48 47K R49 Q6 C2120 Q7 Q8 C2120 Q C /1KV C PF/250VAC C PF 250VAC 4 C TR3 DRIVER R4 22K D10 AC FILTER OUTPUT C8 100UF/50V R R5A 10 R5B 10 D1 Q1 FP460 R6 330 R7 /2W U3A LM324 1 R53 R C R54 R R81 1M R TR1 BOOST Q2 FP460 R8 /2W Q10 R Q11 L=140UH R55 10 D13 R60 10 C34 ZD4 15V D14 D2 MUR860 ZD5 15V 680K 620K C72 0 C73 0 R82 47K R9 R10 8.5k Q12 FP460 Q13 FP460 R83 2.4K C10 680UF 250V C11 680UF 250V C41 3.3UF/250V R65 47/3W C /1KV R11 100K/1W R12 100K/1W TR4 M.TR C /630V R84 47/3W C36 220UF/25V R66 15/1W C D15A 20DL2C D15B C C D16A 20DL2C D16B C R67 15/1W 240K 240K Q14 FAN C43 0 C47 0 R13 R86 22K L5 14UH/40A C U2 TOP222Y R14 15K R UF4005 D3 R87 2.2K C37 TR2 AUX PS ZD1 200V/1W D S C C16 R U3C LM324 8 R88 390K out 1 L6 0.5UH/40A C50 0UF/25V NOTE : ALL RESISTORS ARE IN OHM&1/4W UNLESS SPECIFIED TITLE : SPS SCH INPUT VAC DWG.NO. : HZ DRAWN BY : CHECKED BY : APPROVED BY : D5 RGP10G C /100V C17 47UF/16V 10 9 C38 1UF/50V C57 D6 R16 18 ZD2 6.2V Q3 R17 1K C52 C UF 1000UF 0.22 C54 R69 R75 C15 1UF/50V C58 UF L4 3.3UH C13 UF/25V D7 R89 9.1K R70 R76 R90 56K R71 R77 C59 100UF 25V C60 C55 R72 R78 C14 220UF/25V R91 15K V A M1 M2 C R68 1KV 330/1W R73 R79 * C61 UF C39 R74 R80 C62 100UF 25V C12 uf/500v R92 PG-103J MANSON ENGINEERING INDUSTRIAL LTD. SHEET 1 OF 1 REVISION: 1.6 DATE: D C B A
9
MANSON ENGINEERING INDUSTRIAL LTD. SERVICE MANUAL FOR SPS-9400
MANSON ENGINEERING INDUSTRIAL LTD. SERVICE MANUAL FOR SPS-9400 CONTENTS 1. PRODUCTION SPECIFICATION P.1 2. ALIGNMENT PROCEDURE P.2 3. TROUBLE SHOOTING P.5 4. CHANGE OF ELECTRONIC COMPONENTS P.6 5. DIAGRAMS
More informationPOWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.
POWER SUPPLY MODEL XP-800 TWO AC VARIABLE VOLTAGES; 0-120V and 0-40V @ 7A, PLUS 0-28VDC @ UP TO 10A Instruction Manual Elenco Electronics, Inc. Copyright 1991 Elenco Electronics, Inc. Revised 2002 REV-I
More informationVariable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A
Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A Copyright Elenco Electronics, Inc. REV-D DC POWER SUPPLY 1 2 4 5 CURRENT VOLTAGE 13 3 6 C.C. C.V. 7 FINE COARSE FINE COARSE
More informationHT3003PB HT3005PB MULTI-OUTPUT DC REGULATED POWER SUPPLY
HT3003PB HT3005PB MULTI-OUTPUT DC REGULATED POWER SUPPLY This series include two-way and three-way DC regulated power supply. Three-way have high accuracy output of which two way are adjustable and one
More informationSSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /
SSP-7080 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing USER MANUAL Rev.1.1 2007/04 7673-7080-0000 CONTENTS Warning, Cautions and Operating Conditions P.1 Introduction
More informationCIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)
CIRCUIT-TEST Switching Mode Power Supply with Remote Sensing PSC-9800 0-16V 5A / 0-27V 3A / 0-36V 2.2A (80W) OPERATION MANUAL 1 2 PSC-9800 08R14 Contents Safety Precautions...page 4 Introduction... 5 Controls
More informationMY /2-DIGIT DIGITAL MULTIMETER Users Manual
MY-65 4 1/2-DIGIT DIGITAL MULTIMETER Users Manual Read the Users Manual thoroughly before use. WARRANTY This instrument is warranted to be free from defects in material and workmanship for a period of
More informationLAVOLTA DC REGULATED POWER SUPPLY BPS-305
LAVOLTA DC REGULATED POWER SUPPLY BPS-305 USER MANUAL 1 In order to use the power supply better, please read the user manual carefully before using and keeping it properly. Warning: Do not connect any
More information90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 1410 90W DC Power Supply User Manual Safety Summary The following safety precautions
More informationBENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0
BENCHTOP INSTRUMENT Single Channel DC Power Supply SL Series Operation Manual V1.0 CONTENTS 1. INTRODUCTION... - 1-2. PRODUCTION MODELS... - 1-3. SPECIFICATIONS... - 2-4. PANEL CONTROLS AND INDICATORS...
More informationDC REGULATED POWER SUPPLY
INSTRUCTION MANUAL Models 1620A/ 1621A/ 1622A/ 1623A/ 1626A/ 1627A MANUAL DE INSTRUCCIONES DC REGULATED POWER SUPPLY TABLE OF CONTENTS 1. INTRODUCTION... 3 2. FEATURES... 3 3. SPECIFICATIONS... 4 4. PRCAUTIONS
More informationDC REGULATED POWER SUPPLY
INSTRUCTION MANUAL Models 1620A/ 1621A/ 1622A/ 1623A/ 1626A/ 1627A DC REGULATED POWER SUPPLY Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com TABLE OF CONTENTS
More informationBENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www. BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0 Take off the fuse,
More informationInstruction Manual. Model Y5020. Current Shunt. P/N September 1979
Instruction Manual Model Y5020 Current Shunt P/N 516591 September 1979 INTRODUCTION The Model Y5020 is a precision, four-terminal, current shunt designed for use in calibrating ac/dc current sources in
More informationINSTRUCTION MANUAL Model 1743B
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com INSTRUCTION MANUAL Model 1743B 0-35 V, 0-6 A DC POWER SUPPLY With Dual 4-Digit LED Displays TEST INSTRUMENT
More informationON Semiconductor NCL32073LED1GEVB 9 W High Power Factor LED Driver Evaluation Board User Manual
NCL32073LED1GEVB 9 W High Power Factor LED Driver Evaluation Board User Manual Rev 01 2/6/17 Page 1 Overview ON Semiconductor This manual covers the specification, theory of operation, testing and construction
More informationOPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6. 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 2.0
OPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 2.0 TABLE OF CONTENTS Section Number DANGER PRODUCT INFORMATION 1 -SAFETY AND CAUTION NOTES -DESCRIPTION
More informationNotes: Note1: values at nominal input voltage and full load. 8.5VDC 5V 8V. Open, Efficiency vs. Input Voltage. Efficiency [%]
Features ICE Technology* Description +115 C Maximum Case Temperature -45 C Minimum Case Temperature Built-in EMC Filter Ribbed Case Style 22VDC Isolation Wide 4:1 Input Voltage Range EN-522 Class B The
More informationOrdering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES
Switching Power Supply S82F Industrial-Grade Power Supply for General or Peak Load Applications Correct input voltage range is automatically selected: 1 VAC or 2 VAC. Model S82F-P is suitable for peak
More informationPM300E Voltage Regulator Instruction Manual
PM300E Voltage Regulator Instruction Manual A Regal Brand 1. INTRODUCTION The PM300E voltage regulator is an encapsulated electronic voltage regulator which controls the output of a brushless AC generator
More informationIDEAL INDUSTRIES INC. TECHNICAL MANUAL - SUPPLEMENT MODEL
IDEAL INDUSTRIES INC. TECHNICAL MANUAL - SUPPLEMENT MODEL 61-791 The Service Information provides the following: This is a Supplemental Manual to Megger s DM220 Service Manual and is intended for Performance
More informationPOWER AMPLIFIER SERVICE MANUAL CONTENTS
POWER AMPLIFIER CONTENTS Performance Specifications... 2 Notes... 2 Rear Panel... 3 Section Location... 3 Block Diagram... 4 Interconnection Diagram... 5-8 Multi-channel Schematic and PCB... 9 Heatsink
More informationNXE1 Series Isolated 1W Single Output SM DC/DC Converters
NXE1 Series SELECTION GUIDE FEATURES Patents pending Lower Profile UL695 Recognition pending ANSI/AAMI ES661-1 Recognition pending 3kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture
More informationoutput Output Voltage min (ma)
SERIES: VBT1-SMT DESCRIPTION: DC-DC CONVERTER date 11/01/2012 page 1 of FEATURES 1 W isolated industry standard 8 pin SMT package dual unregulated s 1,000 V isolation short circuit protection UL safety
More informationPRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT
Sheet 1 of 6 Order Number Serial Number PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT Issue Date Level A 22/10/02 Initial issue. Summary of changes Due to RMS continuous product improvement policy
More informationModel Number Output Voltage Output Amps Input Range Max. Iin FL Efficiency Max Output Power
Small 2.32 x 0.9 x 0.37 Size Constant Frequency High Typical Efficiency of 90% (12Vout) Low Output Noise 18 to 60VDC Input Voltage Range Output Over Voltage Protection Current Limit/Short Circuit Protection
More informationHD110C Heavy-Duty Digital Multimeter
HD110C Heavy-Duty Digital Multimeter Key features: Measures 1500 VDC CAT IV 1000 V IP67 Rated Magne-Grip holster with magnetic hanging strap No hassle warranty No waiting. No shipping charges. Our commitment
More information3000 Series Operation Manual
Operation Manual Copyright Copyright 1995 by this company. All rights reserved. No part of this publication may be reproduced in any form or by any means without the written permission of this company.
More informationSELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current
SELECTION GUIDE NXE2 Series FEATURES Patents pending Lower Profile UL69 Recognised ANSI/AAMI ES661-1 Recognised 3kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture Industry
More informationSelectable Impedance Adapter
Selectable Impedance Adapter (Item #5615) (Manual 410) M.C. Miller Co., Inc. 11640 US Highway 1 Sebastian, FL 32958 772.794.9448 sales@mcmiller.com www.mcmiller.com Revised 7/11/2016 High Impedance Buffer
More informationINSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B
INSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES PBA20-12 PBA20-24 OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B68-0175-00 About Brands and Trademarks Our company and product names described
More informationNXE2 Series Isolated 2W Single Output SM DC-DC Converters
SELECTION GUIDE NXE2 Series FEATURES Patents pending Lower Profile UL69 Recognised ANSI/AAMI ES661-1 Recognised 3kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture Industry
More informationSELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current
SELECTION GUIDE FEATURES Patents pending Lower Profile UL9 Recognised ANSI/AAMI ES1-1 Recognised 3kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture Industry Standard Footprint
More informationNote1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]
Features ICE Technology* Description +115 C Maximum Case Temperature -45 C Minimum Case Temperature Baseplate Case Style 2250VDC Isolation Wide 4:1 Input Voltage Range EN-50155 and EN-50121-3-2 Certified
More informationNote1: Typical values at nominal input voltage and full load. 39VDC. Efficiency vs. Input Voltage. Efficiency [%]
Features ICE Technology* Description +115 C Maximum Case Temperature -45 C Minimum Case Temperature Built-in EMC Filter Baseplate Case Style 2250VDC Isolation Wide 4:1 Input Voltage Range EN-50155 and
More informationBoston Gear Ratiotrol DC Motor Speed Control
Boston Gear Ratiotrol DC Motor Speed Control P-3049-BG Doc. No. 83721 Installation and Operation RG1 and RG2 Models 1/6-1 HP a division of Altra Industrial Motion Contents General Information.....................
More informationSELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input Current. Input reflected ripple current
SELECTION GUIDE FEATURES Patents pending Lower Profile UL9 Recognition pending ANSI/AAMI ES1-1 Recognition pending 3kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture Industry
More informationKILOVOLT POWER SUPPLY
Instruction Sheet for the PASCO Model SF-9586 KILOVOLT POWER SUPPLY 012-02815D 1/95 $1.00 SF-9586 KILOVOLT POWER SUPPLY ON kv HIGH VOLTAGE ADJUST OFF 6 KV 6.3 VAC CAUTION! HIGH VOLTAGE 3 KV 3 KV Introduction
More information1. SAFETY TERMS AND SYMBOLS. Contents. 1. Safety terms and symbols Installation Operation.. 4
Contents 1. Safety terms and symbols.. 1 2. Installation... 2 3. Operation.. 4 4. Panel Description.. 8 5. Calibration... 11 6. Circuit Principle 14 7 Block Diagram... 15 8. Specification 16 9. Maintenance
More informationBoston Gear Ratiotrol
Boston Gear Ratiotrol DC Motor Speed Control Installation and Operation Doc. No. 3721 RG1 and RG2 Models 1/6-1 HP GENERAL INFORMATION DESCRIPTION Series RG Controllers statically convert single-phase AC
More informationMTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters
www.murata-ps.com MTU2 Series SELECTION GUIDE FEATURES Patent Protected UL 9 Recognised Footprint over pins.69cm 2 Single & dual isolated output 1kVDC Isolation Hi Pot Test Efficiency up to 85% (Typ.)
More informationSwitching DC Power Supply
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary
More informationPG02S Series 2W DC/DC CONVERTER, SIP-Package
PG02S Series 2W DC/DC CONVERTER, SIP-Package FEATURES Efficiency up to 81% SIP Package with Industry Pinout Small Footprint: 21.8 x 9.3 mm (0.86 x 0.37 inch) Wide 2:1 Input Range Operating Temperature
More informationUCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet
Combined Power Supply & Battery Charger Data Sheet INTRODUCTION UCS-CHR24V55W is a combined charger and power supply with dedicated outputs for both charging and power supply. With a large input range
More informationPRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY
Sheet 1 of 7 Order Number Serial Number PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY Issue Date Level C /04/1996 Initial issue. Summary of changes Due to RMS continuous product improvement
More informationA Caspian Technology Company all materials presented are trade mark and copyright protected by C.M.TECHNOLOGY Pty Ltd
PPS12 230v AC to 12 VDC POWER SUPPLY WITH BATTERY MANAGER OPTION 2 Table of Contents Introduction:... 3 1.0: Input Voltage:... 4 1.1: Mains Hold Up (missing mains cycles):... 4 1.2: Mains Input:... 4 1.3:
More informationSales: Technical: Fax:
DATA SHEET Order code Manufacturer code Description 84-251 n/a RB-55S 1W SGL OUTPUT CONVERTER SIL RC 84-2511 n/a RB-512S 1W SGL OUTPUT CONVERTER SIL RC 84-2512 n/a RB-515S 1W SGL OUTPUT CONVERTER SIL RC
More informationMASTR II/III 12/24V Power Supply 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz 19A149979P3 220VOLT/60 Hz
Maintenance Manual LBI-38551 Rev. D, May-04 MASTR II/III 12/24V Power Supply 19A149979P1-120 VOLT/60 Hz 19A149979P2-230 VOLT/50 Hz 19A149979P3 220VOLT/60 Hz M/A-COM Technical Publications would particularly
More informationMTU1 Series Isolated 1W Single & Dual Output SM DC/DC Converters
www.murata-ps.com MTU1 Series SELECTION GUIDE FEATURES Patent Protected UL60950 recognised Footprint over pins 0.69cm 2 Single & dual isolated output 1kVDC Isolation Hi Pot Test Efficiency up to 88% (Typ.)
More informationNXE1 Series Isolated 1W Single Output SM DC-DC Converters
NXE1 Series SELECTION GUIDE Order Code 1 Nominal Input Voltage Output Voltage Input Current Output Current Load Regulation (Typ) Load Regulation (Max) Output Ripple & Noise (Typ) Output Ripple & Noise
More informationSYMBOL PARAMETER FOR BOOST CONVERTER CONDITIONS MIN TYP MAX UNITS
DEMO CIRCUIT 383B QUICK START GUIDE LT1930ES5/LT1931ES5 1.2MHz, SOT-23 DC/DC CONVERTER DESCRIPTION Demonstration Circuit 383B is multipurpose demonstration board featuring the LT1930 and LT1931. The demo
More informationNXJ2 Series Isolated 2W Single Output SM DC-DC Converters
NXJ2 Series SELECTION GUIDE FEATURES Patents pending Lower Profile UL69 Recognition pending ANSI/AAMI ES661-1, 2 MOOP, 1MOPP recognition pending 5.2kVDC Isolation Hi Pot Test Substrate Embedded Transformer
More informationAC/DC Converter MBP250-2A13D13M
250W, 165-264VAC Input, Dual output AC/DC battery charging module power supply FEATURES Low stand-by power consumption, Maximum instantaneous power up to 350W With charging function, the 12V output Lead-acid
More informationSeries AM2D-RZ 2 Watt DC-DC Converter
Click on Series name for product info on aimtec.com FEATURES: Models Single output Model Input RoHS Compliant Operating Temperature - o C to +85 o C High Efficiency up to 89% Pin Compatible with Multiple
More informationsales@easby.co.uk 01748 850 555 www.easby.com sales@easby.co.uk 01748 850 555 www.easby.com ONE OUTPUT 1W to 3W - Small Compact Size MAIN FEATURES: Small Compact Size - PCB Mount Single Output Output
More informationRUZ- _/_ Protection (3) Isolation Option (4)
Features Unregulated Converters Description Dual output from a single input rail 1kVDC or 2kVDC input/output basic isolation 1kVDC output/output isolation Power sharing on outputs Optional continuous short
More informationTotal solder points: 93 Difficulty level: beginner advanced 10 LED MONO VU METER K4304 ILLUSTRATED ASSEMBLY MANUAL
Total solder points: 93 Difficulty level: beginner 1 2 3 4 5 advanced 10 LED MONO VU METER K4304 Add a visual readout to your existing or new equipment. ILLUSTRATED ASSEMBLY MANUAL H4304IP-1 Features &
More information99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Instruction Manual Model 1672 Triple Output Power Supply Contents Section Description Page No. CONTENTS 1 1 TEST INSTRUMENT
More informationPRODUCT SPECIFICATION File: EA-600ETF-C10 Date: Mar. 29, 2010
SWITCHING POWER SUPPLY Full Range Rev.:C1.0 Page: 1 of 5 1. SCOPE 2 2. AC INPUT 2 3. DC OUTPUT 2 3.1 VOLTAGE and CURRENT LOAD RANGES 2 3.2 CROSS REGULATION 2 3.3 OUTPUT RIPPLE and NOISE 3 3.4 DYNAMIC DC
More informationCONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS...
CONTENTS SUBJECT PAGE TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS... 8 SEC 4 - BATTERY CHARGING NOTES... 9 SEC 5 - VERIFICATION
More informationLS200 Series Instruction Manual
LS200 Series Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage may lead to an electrical shock, damage to the unit
More informationez1081pre Mic Amplifier - Assembly manual [ Colourbook Issue 1]
ez1081pre Mic Amplifier - Assembly manual [ Colourbook Issue 1] ez1081pre Colourbook Contents. Section 1 - Colourbook assembly guide Section 2 - Setup and Calibration Section 3 - Schematics diagrams and
More informationPRODUCT SPECIFICATION File: EA-520H1U-01 Date: Apr., 7, 2005
SWITCHING POWER SUPPLY Page: 1 of 1 1. SCOPE 2 2. AC INPUT 2 3. DC OUTPUT 2 3.1 VOLTAGE and CURRENT LOAD RANGES 2 3.2 OUTPUT RIPPLE and NOISE 3 3.3 DYNAMIC DC OUTPUT CHARACTERISTICS 3 3.4 DC OUTPUT ON/OFF
More informationEA07. Generator Automatic Voltage Regulator Operation Manual
EA07 Generator Automatic Voltage Regulator Operation Manual Suitable for Single or Three Phase Self Excited Brushless Generator Compatible replacement for Mecc Alte SR-7 * Not a genuine Mecc Alte product.
More informationDC POWER SUPPLY ALIMENTATION C.C.
DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning statements identify
More informationOWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.
OWNER S MANUAL DP AUDIO Model No. DN350 12 Volt DC to 115 Volt AC 150 WATT 300WATT HIGH SURGE POWER INVERTER Please read installation and operation instruction before using this Power inverter. Contents
More informationPressure switches 30 A/F
Pressure switches Attachment options for wall fitting and block style enable clearly structured, accessible, easy-maintenance installation Switching pressure can be adjusted easily by user High overpressure
More informationVAL6 KBE5S. Service Manual
VAL6 KBE5S Service Manual 1 2 Specifications Type VAL6 KBE5S Heat Output 111,000BTU/h Fuel Kerosene, Diesel Tank Capacity 9 gallons Fuel Consumption 0.85gallon/h Power Source 120V, 60Hz single phase Power
More informationSELECTION GUIDE. Nominal Input Voltage. Output Voltage. Input reflected ripple current. Switching frequency NXE1S0305MC 85
SELECTION GUIDE Order Code 1 Nominal Input Voltage Output Voltage Input Current Output Current Load Regulation (Typ) Load Regulation (Max) Output Ripple & Noise (Typ) Output Ripple & Noise (Max) Efficiency
More informationDigital Multimeter User's Manual
Digital Multimeter User's Manual MS8239A MS8239A DIGITAL MULTIMETER Auto Power Off V HOLD 600 600 20 10A A m 10A 20m 2 m V MAX 10A/ 500V COM 600V CAT III IEC61010-1 12V 9V BATT. k 2M 600V MAX MAX ma/250v
More informationType C Track Circuit Uninterruptable Power Supply
Safetran Systems Instruction & Maintenance Model CXP-3 Type C Track Circuit Uninterruptable Power Supply Instruction & Maintenance Type C Track Circuit Uninterruptable Power Supply Contents Introduction...2
More information2W, Low Cost DIP, Dual Output DC/DC Converters
2W, Low Cost DIP, Dual Output DC/DC s Key Features Low Cost 500 Isolation MTBF > 0,000 Hours mv P-P Ripple and Noise Input 12 Output {15 Temperature Performance -25] to +71] Short Circuit Protection UL
More informationISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.
ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c. ISO-TECH IPS 1810H 204-713 ISO-TECH IPS 1603D 204-729 82IP-1810HME Ei Statement of Compliance
More informationADVR-12. Hybrid Universal Analog Digital Voltage Regulator Operation Manual
ADVR-12 Hybrid Universal Analog Digital Voltage Regulator Operation Manual Adapter plugs for Digital Regulator Self Excited Automatic Voltage Regulator For use in Brushless PMG and Auxiliary Winding 4501
More informationHPP1 MK5 Owner s Manual
J Wolmarans Page 1 2016/09/15 Page 1 of 9 TABLE OF CONTENTS Page 1 Introduction...2 2 Models...2 3 Safety warnings...3 4 Contents...3 5 Installation...3 5.1 Mounting the unit:...3 5.2 Connecting the battery:...3
More informationNXJ1 Series Isolated 1W Single Output SM DC-DC Converters
SELECTION GUIDE FEATURES Patents pending Lower Profile UL9 Recognised ANSI/AAMI ES-, 2 MOOP, MOPP Recognised 4.2kVDC Isolation Hi Pot Test Substrate Embedded Transformer Automated Manufacture Industry
More informationAC Wattmeters and VArmeters
AC Wattmeters and VArmeters The Crompton Instruments Switchboard series of AC Wattmeters and VArmeters incorporate a DC moving coil, pivot and jewel indicator with a micro-circuit watt transducer PCB to
More informationOutdoor 200 W 2 Channel SL-L2701B0N1KR
Product Data Sheet Rev. 1.0 2017.09.07 1# LED Driver Outdoor 200 W 2 Channel SL-L2701B0N1KR High Efficiency Constant Current LED Driver With Active Power Factor Correction Features & Benefits Output Current:
More informationDrive electronics pq11
Drive Electronics pq 11 Plug-in type amplifier for proportional valves Output current for solenoids: 0... 1000 ma or 0... 2400 ma Catalog Register A17, P17, H17 Publication 7502961.06.11.96 Description
More informationSELECTION GUIDE - SINGLE OUTPUT 1. Nominal Input Voltage Output Voltage
www.murata-ps.com SELECTION GUIDE - SINGLE OUTPUT 1 Order Code Nominal Input Voltage Output Voltage Output Current Input Current at Rated Load Load Regulation (Typ) Load Regulation (Max) Ripple & Noise
More information100W SUBWOOFER KIT. Total solder points: 383 Difficulty level: beginner advanced K8077 ILLUSTRATED ASSEMBLY MANUAL
100W SUBWOOFER KIT Powerful bass from a small cabinet thanks to the dual speaker principle Total solder points: 383 Difficulty level: beginner 1 2 3 4 5 advanced K8077 ILLUSTRATED ASSEMBLY MANUAL H8077IP-1
More informationMEA1 Series 1kVDC Isolated 1W Dual Output DC/DC Converters
www.murata-ps.com MEA1 Series FEATURES UL 695 recognised Typical efficiency to 89.5% 1kVDC isolation Hi Pot Test Wide temperature performance at full 1 Watt load, 4 C to 85 C Industry standard pinout Power
More informationGeneral Purpose Relay
General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)
More informationPRODUCT SPECIFICATION File: EA-400H2U-02 Date: Feb., 16, 2005
SWITCHING POWER SUPPLY Page: 1 of 1 1. SCOPE 2 2. AC INPUT 2 3. DC OUTPUT 2 3.1 VOLTAGE and CURRENT LOAD RANGES 2 3.2 CROSS REGULATION 2 3.3 OUTPUT RIPPLE and NOISE 3 3.4 DYNAMIC DC OUTPUT CHARACTERISTICS
More informationPLATINUM SERIES SWITCHBOARD METERS
PLATINUM SERIES SWITCHBOARD METERS www.sifamtinsley.co.uk DATASHEET E471457 Multifunction Meters Transducers & Isolators PLATINUM SERIES SWITCHBOARD METERS Temperature Controllers Converters & Recorders
More informationDC POWER SUPPLY (Switching mode)
DC POWER SUPPLY (Switching mode) ISO-TECH IPS1820D RS Stock No. 357-0760 ISO-TECH IPS3610D RS Stock No. 357-0776 ISO-TECH IPS606D RS Stock No. 357-0782 82IP-3610DMB Ei SAFETY TERMS AND SYMBOLS These terms
More informationBENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0
BENCHTOP INSTRUMENT Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0 CONTENTS 1. INTRODUCTION... - 1-2. PRODUCTION MODELS... - 2-3. SPECIFICATIONS... - 3-4. PANEL CONTROLS
More informationOpen Frame Power Supplies
, 0 300 Watt Features Small and compact PCB Construction Optional with Chassis and Cover Universal Input 8 264 VAC, Output Voltage adjustable Compliance to E 6000-3-2 (PFC) EMI meets E022, Class B and
More informationSolar Inverter/Charger
Solar Inverter/Charger PV1100 PLUS Table of Contents 1. General Information...1 1.1 Brief Introduction. 1 1.2 Inverter Schematic Diagram.1 1.3 Inverter Components Instructions... 2 2. Fault Code...3 3.
More informationCX-SERIES ADVANCED BATTERY CHARGER
CX-SERIES ADVANCED BATTERY CHARGER Table of Content 1. IMPORTANT SAFETY INFORMATION... 2 1-1 General Safety Precautions... 2 1-2 Battery Precautions... 2 2. FEATURES... 3 2-1 Battery Charging Curve...
More informationASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.
ASTROAI USER MANUAL DIGITAL MULTIMETER NOTE: Fully read and understand this manual before using this instrument. WARNING: To avoid possible electric shock or personal injury, and to avoid possible damage
More informationPRODUCT SPECIFICATION File: EA- 400ET1-10 Date: Jul., 28, 2006
SWITCHING POWER SUPPLY Page: 1 of 5 1. SCOPE 2 2. AC INPUT 2 3. DC OUTPUT 2 3.1 VOLTAGE and CURRENT LOAD RANGES 2 3.2 CROSS REGULATION 2 3.3 OUTPUT RIPPLE and NOISE 3 3.4 DYNAMIC DC OUTPUT CHARACTERISTICS
More informationPower Controller. (see note 1) 10 sec
Power Controller Single-phase Models EUN Series AC Power Controller with Phase-control System Allows Precise Temperature Control Models with Base-up and Soft-start Functions Available EH Series Phase Control
More informationAbbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL
Abbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL DESCRIPTION. The Model BD-50E is a rugged tester designed for testing tank lining and other applications where extended use is necessary.
More informationESD5500E Series Speed Control Unit
ESD5500E Series Speed Control Unit 1 SPECIFICATIONS INTRODUCTION PERFORMANCE Isochronous Operation ± 0.25% or better Speed Range / Governor 1-7.5 KHz Continuous Speed Drift with Temperature ±1% Maximum
More informationPRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0
PRO POWER 2 0 A L I T H I U M B AT T E RY C H AR G E R M O D E L : P P - L B C - 1 2 2 0 V E R S I O N : V 1. 0 Contents 1. Revised History... 1 2. Warning... 1 3. Notes... 1 4. Product Number System...
More informationSwitching Power Supply
Switching Power Supply Easy-to-use Industrial Power Supply with Versatile Functions (); Power Supply Suitable for Peak Loads such as Motors and Solenoids (-P) Remote control function incorporated. Remote
More informationInstruction Manual PFE500F 1000F SERIES. TDK-Lambda PFE500F 1000F Series INSTRUCTION MANUAL
PFE500F 1000F SERIES Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before
More informationT621 Repair Manual (Electronics)
T621 Repair Manual (Electronics) Table of Contents 1-1-1. Product Picture-T621 1-2-1. Display-T621 1-3-1. Component Placement-T621 Display 1-3-2. Component Placement-T621 Drive Board Area 1-4-1. Block
More informationVACUUM INTERRUPTER TEST SET
Users Manual Phenix Technologies Inc. VACUUM INTERRUPTER TEST SET Model Number 660-10P Version 3.2 TABLE OF CONTENTS Section Number GENERAL SAFETY PRECAUTIONS SPECIFICATIONS 1 CONTROL AND METERING DESCRIPTION
More information