MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Size: px
Start display at page:

Download "MY /2-DIGIT DIGITAL MULTIMETER Users Manual"

Transcription

1 MY /2-DIGIT DIGITAL MULTIMETER Users Manual Read the Users Manual thoroughly before use. WARRANTY This instrument is warranted to be free from defects in material and workmanship for a period of one year. Any instrument found defective within one year from the delivery date and returned to the factory with transportation charges prepaid, will be repaired, adjusted, or replaced at no charge to the original purchaser. This warranty does not cover expandable items such as batteries or fuses. If the defect has been caused by a misuse or abnormal operating conditions, the repair will be billed at a nominal cost. SAFETY INFORMATION UT30B digital multimeter has been designed according to IEC-1010 concerning electronic measuring instruments with an overvoltage category (CATⅡ) and pollution2. Full compliance with safety standards can be guaranteed only with test leads supplied. If necessary, they must be replaced with the type specified in the manual. ELECTRICAL SYMBOLS AC (Alternating Current) DC (Direct Current) Important safety information. Refer to the manual. Dangerous voltage may be present. Earth ground Fuse Conforms to European Union directives Double insulated WARNING To avoid possible electric shock or personal injury, follow these guidelines: Do not use the meter if it is damaged. Before you use the meter, inspect the case. Pay particular attention to the insulation surrounding the connectors Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity. Replace damaged test leads before you use the meter. Do not use the meter if it operates abnormally. Protection may be impaired. When in doubt, have the meter serviced. Do not operate the meter around explosive gas, vapor, or dust. Do not apply more than the rated voltage, as marked on the meter, between terminals or between any terminal and earth ground. Before use, verify the meter s operation by measuring a known voltage. When servicing the meter, use only specified replacement parts. Use with caution when working above 30V ac rms, 42V peak, or 60V dc. Such voltages pose a shock hazard. When using the probes, keep your fingers behind the finger guards on the probes. Connect the common test lead before you connect the live test lead. When you disconnect test leads, disconnect the live test lead first.

2 Remove the test leads from the meter before you open the battery door. Do not operate the meter with the battery door or portions of the cover removed or loosened. To avoid false readings, which could lead to possible electric shock or personal injury, replace the batteries as soon as the low battery indicator ( ) appears. CAUTION To avoid possible damage to the meter or to the equipment under test, follow these guidelines: Disconnect circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance. Use the proper terminals, function, and range for your measurements. Before measuring current, check the meter s fuses and turn power OFF to the circuit before connecting the meter to the circuit. Before rotating the range switch to change functions, disconnect test leads from the circuit under test. Before attempting to insert transistors for testing, always be sure that the test leads have been disconnected from any measurement circuits. MAINTENANCE Before opening the case, always disconnect the test leads from all live circuits. For continue protection against fire, replace fuse only with the specified voltage and current ratings: F 250mA/250V (Fast Blown) Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. INTRODUCTION MY-65 Digital Multimeter is a handheld 4 1/2-digit LCD digital multimeter with the advantages of precision reading and stable performance etc., and can be used for the measurement of DC voltage, AC voltage, DC current, AC current, resistance, capacitance, diode, frequency and continuity. It is an ideal instrument for use in the field, laboratory, workshop, and home. FRONT PANEL 1. Power switch 2. LCD 3. Input jack GENERAL SPECIFICATIONS Display: 3 3/4-digit LCD, Max. reading 3999 Automatic polarity indication, - displayed for negative polarity Automatic over-range indication with figure 1 displayed

3 Auto power-off Operating temperature: 0 ~50 Storage temperature: -40 ~60 Low battery indication: symbol displayed on the upper left of the LCD. Dimensions: 70(W) 155(L) 39(H)mm Weight: approx. 250g SPECIFICATIONS Accuracy is specified for a period of one year after calibration and at 18 ~28 with relative humidity to 75%. Accuracy specifications take the form of: ±([% of Reading]+[number of Least Significant Digits]) DC VOLTAGE 200mV 0.01mV ±(0.05%+3) 2V 0.1mV ±(0.1%+3) 20V 1mV ±(0.1%+3) 200V 10mV ±(0.1%+3) 1000V 0.1mV ±(0.15%+5) Input impedance: 10MΩ Overload protection: Range 200mV: 250Vdc or ac rms Other ranges: 700V rms or 1000V peak AC VOLTAGE (50~60Hz) Accuracy (40~1000Hz) 2V 0.1mV ±(0.5%+10) ±(1.0%+10) 20V 1mV ±(0.6%+10) ±(1.0%+10) 200V 10mV ±(0.6%+10) ±(1.0%+10) 700V 0.1V ±(0.8%+15) ±(1.2%+15) Input Impedance: 2MΩ Overload protection: 700V rms or 1000V peak Indication: Average (rms of sine wave) DC CURRENT 2mA 0.1µA ±(0.5%+5) 20mA 1µA ±(0.5%+5) 200mA 10µA ±(0.8%+5) 10A 1mA ±(2.0%+10) Overload protection: 250mA/250V fused (range 10A unfused) Max. input current: 10A (Can not last for more than 10 seconds.) AC CURRENT 2mA 0.1µA ±(0.8%+10) 20mA 1µA ±(0.8%+10)

4 200mA 10µA ±(1.2%+10) 10A 1mA ±(2.5%+10) Overload protection: 250mA/250V fused (range 10A unfused) Max. input current: 10A (Can not last for more than 10 seconds.) Frequency: 40Hz~1000Hz Indication: Average (rms of sine wave) RESISTANCE 200Ω 0.01Ω ±(0.5%+10) 2KΩ 0.1Ω ±(0.3%+5) 20KΩ 1Ω ±(0.3%+2) 200KΩ 10Ω ±(0.3%+2) 2MΩ 100Ω ±(0.3%+2) 20MΩ 1KΩ ±(0.5%+2) 200MΩ 10KΩ ±[ 5.0%(rdg-1000)+10 ] Overload protection: 250Vac rms Note: In range 200MΩ, it is normal that number 1000 is displayed on the LCD when the test leads is shorted, and the number must be subtracted from the reading while making measurement. CAPACITANCE 2000pF 0.1pF ±(4.0%+10) 20nF 1pF ±(4.0%+10) 200nF 10pF ±(4.0%+10) 2µF 100pF ±(4.0%+10) 20µF 1nF ±(4.0%+10) FREQUENCY 20KHz 1Hz ±(1.5%+5) Overload protection: 250Vac rms Input voltage: 200mV~10V rms AUDIBLE CONTINUITY Range Description If the resistance under measurement is less 70Ω, the built-in buzzer will sound. OPERATING INSTRUCTION MEASURING VOLTAGE 2. Set the rotary switch to the desired V~ or V range and connect the test leads to the source

5 or load to be measured. 3. When only the figure 1 is displayed on the LCD, it indicates that the voltage under measurement is over-range and the rotary switch must be set to higher range. MEASURING CURRENT 1. Connect the black test lead to the COM jack and the red test lead to the ma jack for the current up to 200mA or to the A jack for the current between 200mA and 20A. 2. Set the rotary switch to the desired A~ or A range and connect the test leads in series with the load under measurement. The polarity of the red lead connection will be displayed along with the current value when making DC current measurement. 3. When only figure 1 is displayed, it indicates the current under measurement is over-range and the rotary switch must be set to higher range. MEASURING FREQUENCY 2. Set the rotary switch to the 20KHz range and connect the test leads to the source or load under measurement. NOTE: If the input voltage is above 10V rms, you may read the frequency from the LCD, but the accuracy of the reading is not guaranteed. It is better to use shield cable for measuring small signal to avoid interference. MEASURING RESISTANCE 1. Connect the red test lead to the VΩHz jack and the black test lead to the COM jack. 2. Set the rotary switch to the desired Ω range. 3. Connect the test leads to the resistor to be measured and read the value displayed on the LCD. 4. While measuring in-circuit resistance, disconnected circuit power and discharge all high-voltage capacitors before measuring. MEASURING CAPACITANCE 1. Set the rotary switch to the desired F range. 2. Before inserting the capacitor to be measured into the capacitance testing socket, be sure that the capacitor has been fully discharged. 3. When measuring capacitors with shorter leads, a testing adapter is provided with the meter. Insert the adapter into the capacitance testing socket on the front panel to continue the measurement. WARNING To avoid electric shock, be sure the capacitor measuring adapter has been removed before changing to another range. TESTING DIODE 2. Set the rotary switch to the range and connect the red test lead to the anode of the diode to be tested and the black test lead to the cathode of it. The meter will show the approx. forward voltage drop of the diode. If the connection is reversed, only figure 1 will be displayed. TESTING TRANSISTOR 1. Set the rotary switch to the hfe range.

6 2. Determine whether the transistor to be tested is NPN or PNP, and locate the E, B and C leads. Insert the leads of the transistor into their proper holes of the transistor testing socket. 3. The meter will show the approx. hfe value at the test condition of Ib 10μA and Vce 3.2V. CONTINUITY TEST 2. Set the rotary switch to range and connect the test leads to the two terminals of the circuit to be tested. If the resistance is less than about 70Ω, the built-in buzzer will sound. Battery & Fuse Replacement If appears on the LCD, it indicates that the battery should be replaced. To replace the battery, open the case and replace the exhausted battery with the ratings specified: 9V, NEDA 1604 or 6F22. The fuse rarely needs to be replaced and is blown as a result of the operator s error. To replace the fuse, open the case and replace the blown fuse with the ratings specified: F 250mA/250V. To replace battery or fuse, remove the 2 screws in the bottom of the case and open the case. Replace the battery or fuse with a new one of the same rating. Close case and tighten screws completely. ACCESSORIES Users Manual 1 copy Test Leads 1 pair 9V Battery (NEDA 1604 or 6FF22) 1 piece

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY BACK LIGHT D I G I TA L M U LT I M E T E R DT33B OPERATOR LIMITED WARRANTY AND LIMITATION OF LIABILITY This product will be free from defects in material and workmanship for one year from the date of purchase.

More information

Digital Multimeter User's Manual

Digital Multimeter User's Manual Digital Multimeter User's Manual MS8239A MS8239A DIGITAL MULTIMETER Auto Power Off V HOLD 600 600 20 10A A m 10A 20m 2 m V MAX 10A/ 500V COM 600V CAT III IEC61010-1 12V 9V BATT. k 2M 600V MAX MAX ma/250v

More information

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument. ASTROAI USER MANUAL DIGITAL MULTIMETER NOTE: Fully read and understand this manual before using this instrument. WARNING: To avoid possible electric shock or personal injury, and to avoid possible damage

More information

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual Item ref: 600.101UK & 600.102UK MTB01 & MTB02 DIGITAL MULTITESTERS User Manual Please read this manual thoroughly and ensure all contents are fully understood before using the apparatus. Warning To avoid

More information

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS Instructions for: Digital Multimeter - 6 Function MOdel No: MM19.V3 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions

More information

Model UT601: OPERATING MANUAL

Model UT601: OPERATING MANUAL Table of Contents Title Page Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Display Symbols Measurement

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS CM OPERATING INSTRUCTIONS 9 Function, Auto Range Digital Multi-Meter DM6450 INTERTEK Read this owner s manual thoroughly before use and save. C LISTED US I. DISPLAY FUNCTIONS & SYMBOLS 9 6 10 11 14 8 7

More information

Model UT602/603: OPERATING MANUAL

Model UT602/603: OPERATING MANUAL Table of Contents Title Page Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Display Symbols Measurement

More information

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter INSTRUCTION MANUAL Manual-Ranging Digital Multimeter MM300 DATA HOLD AUDIBLE CONTINUITY BATTERY TEST DIODE TEST 10A 2MΩ ESPAÑOL pg. 13 FRANÇAIS pg. 25 MM300-1390109ART.indd 1 9/21/2015 2:48:00 PM GENERAL

More information

BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0

BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www. BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0 Take off the fuse,

More information

Dawson DDM190D. Digital Multimeter User s Manual

Dawson DDM190D. Digital Multimeter User s Manual Dawson DDM190D Digital Multimeter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Safety Information... 7 Certification... 7 INTRODUCTION...

More information

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery MS5900 Users Manual Table of Contents Introduction Motor and Phase Rotation Indicator is a handheld, battery-operated instrument designed to detect the rotary field of three-phase systems and determine

More information

Volt/mA Calibrator. Manual

Volt/mA Calibrator. Manual Volt/mA Calibrator Manual Safety Information To avoid possible electric shock or personal injury: Never apply more than 30V between any two jacks, or between any jack and earth ground. Make sure the battery

More information

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING #61-085 #61-086 Read First: Safety Information This tester complies with UL3111-1, Cat III-600

More information

Table of Contents Title Page No.

Table of Contents Title Page No. Table of Contents Title Page No. INTRODUCTION 1 SAFETY PRECAUTIONS / WARNINGS 2 CONTROLS AND INDICATORS 4 PREPARATION AND CAUTION BEFORE USE 5 TESTING PROCEDURES 6 A. AC/DC VOLTAGE MEASUREMENT 6 B. RESISTANCE

More information

3-1/2 Digit LCD Multimeter with Tachometer Kit

3-1/2 Digit LCD Multimeter with Tachometer Kit 3-1/2 Digit LCD Multimeter with Tachometer Kit Item 95670 Instructions and precautions Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so

More information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Instruction Manual Model 2831D 4 ½ Digit True RMS Digital Multimeter 1 1. PRODUCT DESCRIPTION 1-1. Introduction Thank you

More information

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols Table of Contents Title Page Introduction Unpacking the Meter Safety Information International Electrical Symbols The Meter Structure Key Functions Rotary Switch Measurement Operation A. Measuring Voltages

More information

True RMS Autoranging Multimeter

True RMS Autoranging Multimeter Owner's Manual True RMS Autoranging Multimeter Model No. 73754 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

MODEL No: TA SAFETY INSTRUCTIONS 2. FEATURES. fig.1. Original Language Version

MODEL No: TA SAFETY INSTRUCTIONS 2. FEATURES. fig.1. Original Language Version Instructions for: digital automotive analyser 14 function WITH IC MODEL No: TA303 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these

More information

Autoranging Multimeter

Autoranging Multimeter Owner's Manual Autoranging Multimeter Model No. 82334 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance

More information

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE ISO-TECH IDM93N DIGITAL MULTIMETER INSTRUCTION MANUAL 1 2 WARNING THE SERVICING INSTRUCTIONS DESCRIBED WITHIN THIS MANUAL ARE FOR USE BY QUALIFIED

More information

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater.

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater. Manual Title: 45 User Supplement Issue: 2 Part Number: 855981 Issue Date: 5/01 Print Date: January 1989 Page Count: 8 Revision/Date: 4, 7/97 This supplement contains information necessary to ensure the

More information

362 Clamp Meter. Users Manual

362 Clamp Meter. Users Manual 362 Clamp Meter Users Manual PN 3622678 August 2010, Rev. 1, 4/13 2010, 2013 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names

More information

Users Manual. Phase Rotation Indicator

Users Manual. Phase Rotation Indicator 9040 Phase Rotation Indicator Users Manual PN 2438546 April 2005, Rev.2, 5/11 2005-2011 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are

More information

373 Clamp Meter. Users Manual

373 Clamp Meter. Users Manual 373 Clamp Meter Users Manual PN 3612805 July 2010 2010 Fluke Corporation. All rights reserved. Printed in Taiwan. Specifications are subject to change without notice. All product names are trademarks of

More information

WENS30C Loop Calibrator

WENS30C Loop Calibrator WENS30C Loop Calibrator Instruction Sheet Introduction The WENS30C Loop Calibrator is a compact souring and measuring tool. The Calibrator tests current loops of 0-24mA or 4-20mA and measures dc voltage

More information

Autoranging Industrial Multimeter

Autoranging Industrial Multimeter Owner's Manual Autoranging Industrial Multimeter Model No. 82005 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation

More information

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc 707 Loop Calibrator Instruction Sheet Introduction The Fluke 707 Loop Calibrator (hereafter, the Calibrator) is a compact sourcing and measuring tool. The Calibrator tests current loops of 0-20 ma or 4-20

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 8/05 Form #270 OPERATING INSTRUCTION MODEL 3005 DIGITAL INSULATION-CONTINUITY TESTER

More information

KMP Insulation-Continuity Tester. Users Manual

KMP Insulation-Continuity Tester. Users Manual KMP 7036 Insulation-Continuity Tester Users Manual KMP7036 Insulation-Continuity Tester Users Manual English September 2011, Rev.1 2011 Amprobe Test Tools. All rights reserved. Printed in China Limited

More information

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT. INSULATION TESTER EARTH MAX. AC 600V LINE AC -+ HOLD V k M LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT M H.V. POWER DATA HOLD TEST ON / OFF 250V 500V 1000V ACV OFF 0 CAT.III 600V INSTRUCTION

More information

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE ISO-TECH IDM97II DIGITAL MULTIMETER INSTRUCTION MANUAL 1 2 WARNING THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED PERSONNEL ONLY. TO AVOID

More information

365 Detachable Jaw True-rms Clamp Meter

365 Detachable Jaw True-rms Clamp Meter 365 Detachable Jaw True-rms Clamp Meter Users Manual PN 3622684 August 2010 2010 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product

More information

INSTRUCTION MANUAL DM5B Fax: (503)

INSTRUCTION MANUAL DM5B Fax: (503) INSTRUCTION MANUAL DM5B 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com email: info@ueitest.com Introduction The DM5B digital multimeter is a pocket sized, hand held, battery operated, voltage, current

More information

COMPONENT-TESTER INSTRUCTION MANUAL

COMPONENT-TESTER INSTRUCTION MANUAL ICT76 COMPONENT-TESTER INSTRUCTION MANUAL ISO-TECH ICT 76 COMPONENT TESTER INSTRUCTION MANUAL 1 2 1. Introduction 1.1 Unpacking and checking When you unpack your new component tester, these are the items

More information

362 Clamp Meter. Users Manual

362 Clamp Meter. Users Manual 362 Clamp Meter Users Manual PN 3622678 August 2010 2010 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks

More information

i400s Calibration Information Introduction

i400s Calibration Information Introduction i400s AC Current Clamp Introduction XWWarning To avoid electric shock or injury, do not perform the performance tests or calibration procedures unless you are qualified to do so. The information provided

More information

USER MANUAL. Insulation Tester + DMM. Model MG320

USER MANUAL. Insulation Tester + DMM. Model MG320 USER MANUAL Insulation Tester + DMM Model MG320 Table of Contents 1. INTRODUCTION 3 2. SAFETY 3 3. METER DESCRIPTION 5 4. CONTROL BUTTONS 6 5. SYMBOLS AND ANNUNCIATORS 6 6. OPERATING INSTRUCTIONS 7 6.1

More information

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Mini Multimeter with Non-Contact Voltage Detector (NCV) Owner s Manual Mini Multimeter with Non-Contact Voltage Detector (NCV) Model No. 82314 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product.

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Digital Clamp Meter DSA500A IMPORTANT: RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. If you find damage, notify the carrier at once. Shipping damage

More information

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to RS-3 PRO RS-1007 PRO CAT IV Analog Clamp meter Series Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com RS-3 PRO RS-1007 PRO CAT IV Analog Clampmeter Series English

More information

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit   for user manual translations USER MANUAL 200A AC Mini Clamp Meter Model MA130 Please visit www.extech.com for user manual translations Introduction Thank you for selecting the Extech Instruments 200A AC Mini Clamp Meter. The MA130

More information

27 II/28 II. Digital Multimeters. Getting Started Manual. Specifications

27 II/28 II. Digital Multimeters. Getting Started Manual. Specifications 27 II/28 II Digital Multimeters Getting Started Manual PN 3368142 September 2009 2009 Fluke Corporation. All rights reserved. Printed in USA. Specifications are subject to change without notice. All product

More information

5.2 PRE-OPERATION PROCEDURE WARRANTY

5.2 PRE-OPERATION PROCEDURE WARRANTY 4/02 Form #314 OPERATING INSTRUCTIONS MODELS DM-210A, 220A, 230A DIGITAL MULTIMETER PLEASE READ THESE OPERATING INSTRUCTIONS CAREFULLY Misuse and or abuse of these instruments cannot be prevented by any

More information

80 Series V Digital Multimeter Safety Information

80 Series V Digital Multimeter Safety Information 80 Series V Digital Multimeter Safety Information Limited Lifetime Warranty. See the Users Manual for the full warranty. Go to www.fluke.com to register your product and find more information. A Warning

More information

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP ISO - TECH IDM 91E DIGITAL MULTIMETER INSTRUCTION MANUAL 1 2 WARNING THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED PERSONNEL ONLY. TO

More information

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Mini Multimeter with Non-Contact Voltage Detector (NCV) Owner s Manual Mini Multimeter with Non-Contact Voltage Detector (NCV) Model No. 82315 REL CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this

More information

User Guide. Model Insulation Tester / Megohmmeter. Introduction

User Guide. Model Insulation Tester / Megohmmeter. Introduction User Guide Model 380363 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380363 provides three test ranges plus continuity

More information

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot. 51 & 52 Series II Thermometer Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Users Manual English September 1999 Rev.2, 11/10 1999-2010 Fluke Corporation,

More information

Digital/Analog Megohmmeter Model 1026

Digital/Analog Megohmmeter Model 1026 Digital/Analog Megohmmeter Model 1026 USER MANUAL 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Table of Contents Warning...3

More information

DIGITAL MULTIMETER INSTRUCTION MANUAL

DIGITAL MULTIMETER INSTRUCTION MANUAL IDM97/97RMS DIGITAL MULTIMETER INSTRUCTION MANUAL ISO - TECH IDM 97/97RMS DIGITAL MULTIMETER INSTRUCTION MANUAL 1 2 WARNING These meters should only be used by experienced personnel. To avoid the risks

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION 11/05 Form #271 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 OPERATING INSTRUCTION Visit us at www.testequipmentdepot.com MODEL 3132 ANALOG INSULATION-CONTINUITY TESTER

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS A.W. Sperry Instruments Inc. AC SNAP-AROUND WITH DC VOLT RANGE MODELS TD-2608 & TD-2608A 1) FEATURES UL Listed Five Functions, 12 Ranges. Tear drop shaped jaws for ease of use in

More information

323/324/325 Clamp Meter

323/324/325 Clamp Meter 323/324/325 Clamp Meter Users Manual PN 4045153 May 2012 2012 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks

More information

Phase Sequence Tester

Phase Sequence Tester User's Guide Phase Sequence Tester Model 8000 Introduction Congratulations on your purchase of the Extech Model 0800 Phase Sequence Tester. This handheld instrument detects the phase sequence of three-phase

More information

Dawson DAN100. Analog Multimeter User s Manual

Dawson DAN100. Analog Multimeter User s Manual Dawson DAN100 Analog Multimeter User s Manual TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the BoxError! Bookmark not defined. Accessories... 4 Safety Information... 6 Certification...

More information

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model User's Manual High Voltage Megohmmeter Analog Insulation Tester plus AC Voltage and Continuity Tests Model 380353 Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects

More information

User Guide. Model Insulation Tester / Megohmmeter

User Guide. Model Insulation Tester / Megohmmeter User Guide Model 380260 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity

More information

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL 72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com

More information

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN Contents 1. Safety Precautions... 1 2. Features... 3 3. Specifications... 4 4. Instrument

More information

Digital/Analog Megohmmeter Model 1026 USER MANUAL

Digital/Analog Megohmmeter Model 1026 USER MANUAL Digital/Analog Megohmmeter Model 1026 USER MANUAL Limited Warranty The Megohmmeter Model 1026, is warranted to the owner for a period of 2 years from the date of original purchase against defects in manufacture.

More information

302+/303 Clamp Meter. Users Manual

302+/303 Clamp Meter. Users Manual 302+/303 Clamp Meter Users Manual PN 4045130 September 2011 2011 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names are trademarks

More information

707Ex. Users Manual. ma Calibrator

707Ex. Users Manual. ma Calibrator 707Ex ma Calibrator Users Manual March 2003 Rev 2 3/03(English) 2003 Fluke Corporation, All rights reserved. Printed in USA All product names are trademarks of their respective companies. Table of Contents

More information

User Guide. Model Insulation Tester / Megohmmeter

User Guide. Model Insulation Tester / Megohmmeter User Guide Model 380260 Insulation Tester / Megohmmeter Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity

More information

User's Guide. True RMS Multim eter. Extech 430

User's Guide. True RMS Multim eter. Extech 430 User's Guide True RMS Multim eter Extech 430 Introduction Congratulations on your purchase of the Extech 430 (part number EX430) True RMS Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC

More information

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com Model ST-5500 Digital Insulation Tester Instruction Manual reedinstruments com Table of Contents Safety... 3 Specifications...4-5 General... 4 Electrical... 5 Meter Description... 6 Operating Instructions...6-7

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION 11/05 Form #273 OPERATING INSTRUCTION MODEL 4105 Disital Earth Resistance Tester 2150 joshua's Path, Suite 302, Hauppauge, NY 11788 Phone : 1-800-645-5398 or 1-639-231-7050 Fax : 1-639-434-3128 E-mail

More information

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3 International Electrical Symbols Caution! Refer to this manual before using the probe Probe is protected by Reinforced or Double Insulation CONTENTS Page 1 INTRODUCTION... 2 2 SPECIFICATIONS... 2 2.1 Electrical

More information

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Model 308A Digital Insulation & Continuity Meter INDEX PAGE INSTRUMENT LAYOUT... 1 INTRODUCTION... 2 SAFETY

More information

T2 Tester. Calibration Information. Introduction. Safety Information

T2 Tester. Calibration Information. Introduction. Safety Information T2 Calibration Information Introduction This calibration information sheet provides the following information for the T2 (hereafter referred to as "the tester"): Safety information Parts and service information

More information

Safety design conforming to the following provisions

Safety design conforming to the following provisions Safety design conforming to the following provisions of IEC61010. Overvoltage category III 300V, pollution degree 2, Overvoltage category II 600V, pollution degree 2, Data hold switch for easy reading

More information

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT CM69 TRMS AC EARTH LEAKAGE CLAMP METER INSTRUCTION MANUAL 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT These instructions contain both information and warnings

More information

Model ½ Digit Multimeter

Model ½ Digit Multimeter www.keithley.com Model 2110 5½ Digit Multimeter Calibration Manual 2110-905-01 Rev. C / August 2013 *P211090501C* 2110-905-01 A Greater Measure of Confidence A Tektronix Company Model 2110 5½ Digit Multimeter

More information

Users Manual. MegOhmMeter

Users Manual. MegOhmMeter 1520 MegOhmMeter Users Manual September 2000 Rev.2, 2/03 2000-2003 Fluke Corporation. All rights reserved. Printed in USA All product names are trademarks of their respective companies. Table of Contents

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. 51 & 52 Series II Thermometer Users Manual English September 1999 Rev.1,

More information

Model Insulation Tester / Megohmmeter. User Manual

Model Insulation Tester / Megohmmeter. User Manual Model 380363 Insulation Tester / Megohmmeter User Manual Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380363 provides three test ranges plus continuity

More information

Declaration of Conformity

Declaration of Conformity We Declaration of Conformity GOOD WILL INSTRUMENT CO., LTD. No. 7-1, Jhongsing Rd, Tucheng City, Taipei County 236, Taiwan GOOD WILL INSTRUMENT (SUZHOU) CO., LTD. No.69 Lushan Road, Suzhou New District

More information

Safety design conforming to the following provisions

Safety design conforming to the following provisions Safety design conforming to the following provisions of IEC61010. Overvoltage category III 300V AC, pollution degree 2 Overvoltage category II 600V AC/DC, pollution degree 2 Protected throughout by double

More information

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to PRM-4 Phase Sequence and Motor Rotation Tester Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com PRM-4 Phase Sequence and Motor Rotation Tester English Users Manual

More information

PTC8001 Temperature Calibrator

PTC8001 Temperature Calibrator PTC8001 Temperature Calibrator Table of Contents 1. Introduction....................1 1.1 Customer Service................1 1.2 Standard Equipment..............1 1.3 Safety Information................2

More information

ATD-5570 DELUXE AUTOMOTIVE METER

ATD-5570 DELUXE AUTOMOTIVE METER Contents ATD-5570 DELUXE AUTOMOTIVE METER INSTRUCTION MANUAL Introduction Safety Getting Started Meter Basics Digital and Analog display Function and Range Select Push-button Functions Alternate Function

More information

INSTRUCTION MANUAL IDM67 DIGITAL MULTIMETER

INSTRUCTION MANUAL IDM67 DIGITAL MULTIMETER INSTRUCTION MANUAL IDM67 DIGITAL MULTIMETER EN FR IT DE JP IDM67 DIGITAL MULTIMETER INSTRUCTION MANUAL 1 2 INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Digital Multimeter from its packing,

More information

233 True-rms Remote Display Digital Multimeter Safety Information

233 True-rms Remote Display Digital Multimeter Safety Information 233 True-rms Remote Display Digital Multimeter Safety Information Go to www.fluke.com to register your product and find more information. A Warning identifies conditions and procedures that are dangerous

More information

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet Go to www.fluke.com to register your product, download manuals, and find more information. A Warning identifies conditions and procedures that are

More information

Calibration Manual. Detachable Jaw True-rms Clamp Meter

Calibration Manual. Detachable Jaw True-rms Clamp Meter 365 Detachable Jaw True-rms Clamp Meter Calibration Manual December 2010 2010 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks

More information

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B Instruction manual High voltage insulation resistance tester KEW3121B/3122B Contents 1. Safety warnings... 1 2. Features... 5 3. Specification... 6 4. Instrument layout... 9 5. Getting started... 10 5-1

More information

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T ) An ISO 9001:2008 Company DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T ) Model - KM 2805 MK-1 insulation resistance tester is a handheld instrument designed primarily to make resistance / insulation resistance

More information

General Specifications

General Specifications General Specifications Maximum Voltage between any Terminals and Grounding: 1000V. Fused for Input Terminal: Model DMM8060/8061Glass fuse, 0.5A, 250V, fast type, 5x20mm. Fused for 10AInput Terminal: DMM8060/8061

More information

INSTRUCTION MANUAL M110A Fax: (503)

INSTRUCTION MANUAL M110A Fax: (503) INSTRUCTION MANUAL M110A 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com email: info@ueitest.com Introduction The M110A, in addition to high-resolution voltage and ohms scales needed for electrical

More information

Visit us at

Visit us at 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Introduction 717 30G & 717 100G Pressure Calibrators Instruction Sheet The Fluke

More information

Digital Multimeter AHMAD FOUAD ALWAN

Digital Multimeter AHMAD FOUAD ALWAN Digital Multimeter AHMAD FOUAD ALWAN What is a Digital Multimeter? Test leads are used to connect the multimeter to the circuit to be tested. 1. To know how to use the Ammeter and how to read the measure.

More information

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1 Instruction Manual ICM A1 AC/DC Clamp Meter EN ICM A1 Warning...................................... Safety sheet.............................................. Read First Safety Information - Use the instrument

More information

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual / User Manual Content 1 Introduction 3 2 Safety 3 3 Specifications RT-ZC03 6 Specifications RT-ZC02 7 4 Operating Instructions RT-ZC03 8 Operating

More information

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings 1587 FC/1587/1577 Insulation Multimeter Safety Information Go to www.fluke.com to register your Product and find more information. A Warning identifies conditions and procedures that are dangerous to the

More information

DIGITAL RCD(ELCB) TESTER

DIGITAL RCD(ELCB) TESTER INSTRUCTION MANUAL DIGITAL RCD(ELCB) TESTER KEW 5410 R KYORITSU ELECTRICAL INSTRUMENTS WORKS, LTD. Contents 1. Safety Warnings.... 1 2. Procedure of removing Cover. 3 2-1 Method of removing the Cover.

More information

IDEAL INDUSTRIES INC. TECHNICAL MANUAL - SUPPLEMENT MODEL

IDEAL INDUSTRIES INC. TECHNICAL MANUAL - SUPPLEMENT MODEL IDEAL INDUSTRIES INC. TECHNICAL MANUAL - SUPPLEMENT MODEL 61-791 The Service Information provides the following: This is a Supplemental Manual to Megger s DM220 Service Manual and is intended for Performance

More information

User's Manual. Earth Ground Resistance Tester. Model Introduction

User's Manual. Earth Ground Resistance Tester. Model Introduction User's Manual Earth Ground Resistance Tester Model 382152 Introduction Congratulations on your purchase of the Extech Earth Ground Resistance Tester. This device can measure resistance (in 3 ranges) and

More information

Switching DC Power Supply

Switching DC Power Supply 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary

More information

Low Amp Probe EETA308A

Low Amp Probe EETA308A Low Amp Probe EETA308A Reference Manual First Edition SAFETY WARNING DO NOT APPLY OVER 150V AC (RMS) OR DC. DISCONNECT LEADS BEFORE REMOVING THE BATTERY COVER. DO NOT ALLOW THE CABLE TO BECOME ENTANGLED

More information