POWER YOUR MINE WITH TF Kable MINING CABLES AUSTRALIA

Size: px
Start display at page:

Download "POWER YOUR MINE WITH TF Kable MINING CABLES AUSTRALIA"

Transcription

1 POWER YOUR MINE WITH TF Kable MINING CABLES AUSTRALIA

2 Table of Contents rubber CABLES 2 TELE-FONIKA Kable 3 PRODUCTION POTENTIAL 5 1 PRODUCTION MATRIX 6 GENERAL UNDERGROUND COAL MINING CABLES TYPE /11 kv 10 TYPE /1.1 kv 13 TYPE /1.1 kv 15 TYPE /11 kv 17 TYPE /11 kv 20 UNDERGROUND METAL AND SURFACE MINING CABLES TYPE /22 kv 25 TYPE /22 kv 28 TYPE /22 kv 31 TYPE /33 kv 34 TYPE /33 kv 37 MACHINE CABLES TYPE 1 1.1/1.1 kv 42 TYPE 2S (IS) 1.2 kv 44 TYPE XLPE SWA PVC 0.6/1 kv 52 heavy duty industrial cables TYPE EMV 0.6/1 kv 56 TYPE SINGLE CONDUCTOR POWER CABLE 0.6/1 kv, C 58 TYPE H07RN-F 450/750 V SUB 60 TYPE NSGAFÖU 0.6/1, 1.8/3, 3.6/6 kv 65 TYPE 07RN-F-CY 450/750 V 68 TYPE NSGAFÖU/CY 1.8/3.3 kv 70 CABLE DRUMS Sample data of wooden cable drums 71 PRINCIPAL ELASTOMERIC MATERIALS USED IN REELING AND TRAILING CABLES 72 RECOMMENDED LIMITS TO REELING AND TRAILING CABLE OPERATION 74

3 RUBBER cables TELE-FONIKA Kable is known as the Number One cable producer in Central and Eastern Europe and is recognised as the leader in rubber cable products. TF Kable has over a dozen rubber production lines, with triple head continuous vulcanization extruding machines, twisters, braiders, amongst other plant to call upon. With our state-of-art instrumentation, which continuously monitor and control the production processes, we can be assured that our products are of the highest standards and quality. TF Kable offers wide range of rubber cables, starting from nominal voltage of 100/100V up to 18/30kV and cross-sections from 0,75 mm 2 up to 1000 mm 2 and from 1 up to 56 cores. TF Kable manufacture cables to national harmonized standards such as DIN VDE (German), BS (British), ICEA i ASTM (American), CSA (Canadian), AS/NZ (Australian/New), NF C (French), SANS (South African), GOST (Russian), to name but a few. 2 Rubber compounds used for manufacturing of rubber insulated and sheathed cables are based on the best synthetic elastomers the market can offer, including EPDM, EVA, SBR and Silicone. Depending on type and application, our rubber insulation compounds will guarantee continuous working temperatures from 60 C through 110 C up to 220 C. For other cables components production, TF Kable uses the following types of rubber compounds: chloroprene, chlorinated polyethylene, chlorosulfonated polyethylene and others, depending on application. Many years of experience in cable production and processing, has allowed TF Kable to develop bespoke materials that meet the demanding installation environments. Cables working in hard conditions such as mines, have specialised polyurethane sheaths which are flame retardant, rending, tear and abrasion resistant, water, oils and other chemicals resistant. Cables are designed and manufactured to ensure the longest and the safest operation in heavy duty conditions in today s mines and other demanding environments.

4 TELE-FONIKA Kable The Group TELE-FONIKA Kable (TF Kable) is ranked in the forefront of the global cable industry. The Group is the third manufacturer of cables and wires in Europe with significant development potential, based entirely on Polish capital. TELE-FONIKA Kable Group s considerable investment in research and development centers and multiskilled work teams, which have included eminent scientists working with our specialists, has been rewarded by the introduction of new-generation products and comprehensive services in the field of cable engineering. Products manufactured in our plants are sold in over 90 countries. Our product assortment includes 25 thousand cable types. The highest quality of our products is confirmed by over 460 certificates for groups of wares licensed by 34 renown centres of certifications worldwide. The company combines the good traditions of the cable industry in Poland and innovative technical solutions. TELE-FONIKA Kable Group consists of seven plants five in Poland, one in Ukraine, and one in Serbia. We own over a dozen trade agencies abroad, reaching customers in several dozen countries around the world. TELE-FONIKA Cable Americas Bolingbrook IL TELE-FONIKA Kable Central Europe Hilden TF Nordic Malmoe TELE-FONIKA Kable Kraków, Bydgoszcz, Szczecin, Myślenice TELE-FONIKA Baltic Kaunas Copper Cable Co. Coalville 3 TOW TF KABEL Chernihiv TF KABEL Kiev TELE-FONIKA France Longvic TELE-FONIKA Kabely Zabreh TF KABLE FK Zajecar Serbia

5 Experience and innovation

6 5 PRODUCTION POTENTIAL Our chief asset is extensive technological know-how in the field of production of wide variety of cables and wires supported by our experienced personnel. Our products match to a great extent the general trends concerning ecology and maintenance safety of wares. Extremely strict legislation in these areas has become the indicator of the technological progress of the manufactured cables. Kraków-Wielicka Plant Kraków-Wielicka Plant was established in In 1992 it received the ISO 9002 certificate (now ISO 9001) and in 1998 the ISO given by the British certification body: BASEC. The plant specializes in the production of rubber insulated cables and wires for mining and industrial applications. All types of rubber mixes used for EPR, CR, EVA and CSP cables are based on an original prescription designed together with research and development centres. The production offer of the plant are also medium voltage cables made in XLPE technology, as well as signal and control wires for special purposes. Kraków-Bieżanów Plant Kraków-Bieżanów Plant was established in In 1992 it received the ISO 9001 certificate and given by the British certification body: BASEC. The plant specializes in the production of overhead conductors from alloyed aluminium, conductors for railway traction network from copper and its alloys and installation wires for general usage. Bydgoszcz Plant Bydgoszcz Plant started production of cables and wires back in In 1992 it received the ISO 9002 certificate (now ISO 9001) and in 1998 the ISO given by the British certification body: BASEC. Bydgoszcz Plant specializes in power supply cables of medium and high voltage up to 400 kv. It is equipped with six modern chain lines for crosslinking polyethylene in XLPE technology. Complementary technological lines for producing the abovementioned cables ranging from thick wire drawing machines, cable stranding machines and screening machines to covering lines and two large-size high voltage laboratories called Faraday cage place the plant in the top of the list of the largest production centres of medium and high voltage cables in Europe. Myślenice Plant Myślenice Plant was established in April 1992 under the name Zakłady Kablowe TELE-FONIKA s.c. In 1995 it received the ISO 9001 certificate and in 1999 the ISO certificate. The certification body is BASEC. In September 2007 the plant received the ISO/TS certificate for automotive cables given by the certification body: SGS. Myślenice Plant specializes in the production of copper and fibre optic telecommunication cables, computer cables and automotive wires. Szczecin Plant Szczecin Plant was established in In 1992 it received the ISO 9002 certificate (now ISO 9001) and in 1998 the ISO given by the British certification body: BASEC. This Plant is also certified according to ISO/TS by SGS. It specializes in production of enamelled magnet wires. TOW TF Kabel (Ukraine) The plant was established in In 2007 the plant was joined into the TELE-FONIKA Kable Group. This Plant is certified according to ISO 9001 and It specializes in the production of overhead conductors and cables for voltage up to 1 kv, including halogenfree, fire resistant and flame retardant cables versions. TF Kable Fabrika Kablova Zajecar A.D. (Serbia) The plant was established in In 2007 the plant was joined into the TELE-FONIKA Kable Group. This plant is certified according to ISO 9001 and by DAS Certification Ltd. It specializes in the production of low and medium voltage cables, as well as halogen-free, fire resistant and flame retardant cables, telecommunication cables and PVC and polyethylenecoated conductors.

7 PRODUCT MATRIX Cable Type Voltage-Range 1.1kV - 11kV 1.1kV 1.1kV 1.1kV - 11kV 1.1kV - 11kV 1.1kV - 22kV Conductor-Range 6 mm mm mm mm 2 16 mm 2-50 mm 2 6 mm mm 2 6 mm mm 2 6 mm mm 2 Conductor - Number Conductor - Copper Tinned Tinned Tinned Tinned Tinned Tinned Conductor - Screen Semi-conductive Semi-conductive - Semi-conductive Semi-conductive Semi-conductive - Type EPR R-EP-90 EPR R-EP-90 EPR R-EP-90 EPR R-EP-90 EPR R-EP-90 EPR R-EP-90 - Screen 1 Semi-conductive Semi-conductive - Semi-conductive Semi-conductive Semi-conductive - Screen 2 CU braid/poly yarn CU braid/poly yarn - CU braid/poly yarn - CU braid/poly yarn Pilot Conductor - Type EPR central EPR central EPR central EPR interstitial EPR central EPR central Pilot Conductor - Number Earth Conductor - Type - - Elastometric interstitial - Elastometric interstitial - 6 Earth Conductor - Number Separators/Fillers/ Reinforcing Strength Members/Armour Cradle separator Cradle separator Cradle separator Cradle separator Cradle separator Cradle separator - - Polyamid braid yarn - Polyamid braid yarn Jacket/Outer HD-85-PCP HD-85-PCP HD-90-CSP HD-85-PCP HD-90-CSP HD-85-PCP Core ID Red, White, Blue Red, White, Blue Red, White, Blue Red, White, Blue Red, White, Blue Red, White, Blue Applications Flexible feeder to machinery Hand held boring machines and srills Shuttle cars and pump applications General purposes Main feeder, mine power, pump applications - General purposes underground metal and surface mining

8 PRODUCT MATRIX S XLPE SWA PVC 1.1kV - 22kV 1.1kV - 22kV 3.3kV - 33kV 3.3kV - 33kV 1.1kV 1.1kV 0.6kV - 1.2kV 6 mm mm 2 6 mm mm 2 16 mm mm 2 16 mm mm mm 2-4 mm mm 2-95 mm mm mm (16, 30) 2-4 Tinned Tinned Tinned Tinned Tinned Tinned Tinned Semi-conductive Semi-conductive Semi-conductive Semi-conductive EPR R-EP-90 EPR XR-EP-90 EPR XR-EP-90 EPR XR-EP-90 V-90 (PVC) EPR R-EP-90 XLPE-90 Semi-conductive Semi-conductive Semi-conductive Semi-conductive Collective Collective/individually - CU braid/poly yarn - CU braid/poly yarn - Tinned copper braid CU braid/poly yarn - EPR interstitial EPR central EPR interstitial EPR interstitial - EPR interstitial Elastometric interstitial Elastometric interstitial Elastometric interstitial - - Interstitial XLPE Cradle separator Cradle separator Center filler Center filler Non-hygroscopic fillers Center filler - Polyamid braid yarn Polyamid braid yarn Polyamid braid yarn Inner sheath 5V-90 (PVC) - - GSW hellical serve armour HD-85-PCP HD-90-CSP HD-85-PCP XHD-90-CSP 5V-90 (PVC) HD-90-CPE 5-V90 (PVC) Red, White, Blue 1 one, 2 two, 3 three Red, White, Blue Red, White, Blue 1 one, 2 two, 3 three 2 one, 2 two, 3 three Red, Black, Green/Yellow Power to machinery and equipment Trailing draglines, shovels, drills, reeling applications Trailing draglines, shovels, drills, reeling applications Stacker/reclamation Non-mobile machines and fixed apparatus Non-mobile machines and fixed apparatus Power networks, outdoors, underground and conduit

9 Coal mining our future

10 GENERAL UNDERGROUND COAL MINING Type 209 Copper Screened Three-core Cables Central Pilot Core Flexible Feeder to Machinery / Hand Held Tools Type 210 Copper Screened Three-core Cables Central Pilot Core Hand Held Boring Machines and Drills Type 275 Three-core Cables Central Pilot Core Interstitial Earth Conductors General Use, Shuttle Cars and Pump Cable Type 240 Copper Screened Three-core Cables Interstitial Pilot Conductors Mine Power / Main Feeder / Long Wall 9 Type 241 Three-core Cables Central Pilot Core Interstitial Earth Conductors Mine Power / Main Feeder / Continuous Miners / Pump Applications

11 TYPE /11 kv 10 TRAILING CABLES Type /11 kv Copper Screened Three-core Cables, Central Pilot Core Flexible Feeder to Machinery General Underground Coal Mining Construction Conductors Tinned annealed copper wires to AS/NZS 1125:2001 and AS/NZS 1802:2003 Conductor screen Semi-conductive thermosetting compound Ethylene propylene rubber R-EP-90 to AS/NZS 3808 screen Semi-conductive thermosetting compound and tinned copper/polyamide braid to AS/NZS 1802:2003 Cradle separator Semi-conductive thermosetting compound and EPR covered Pilot Core (grey) to AS/NZS 1802:2003 Cable assembly Jacket Operating temp Cable tests AS/NZS 1802:2003 Marking Core ID FEATURES Crush resistant central cradle construction Flexible EPR insulation Three screened power conductors laid up with right hand direction on cradle separator with central pilot conductor Thermosetting compound HD-85-PCP heavy duty oil resistant and flame retardant Minimum ambient temperature -25 C Maximum conductor temperature + 90 C Type of cable, size, manufacturer, year Red, White, Blue Short circuit cafety - screened conductors/semi-conductive cradle Heavy duty jacket Oil resistant/flame retardant Rated -25 C to +90 C Specifications & Standards: AS/NZS 1802:2003, AS/NZS 1125:2001

12 TYPE /1.1 kv area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE /3.3 kv 11 area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF /0.40 TF / / TF / / / TF / / TF / / TF / / TF / / TF / / TF / / TF / /

13 TYPE /6.6 kv area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF /0.40 TF / / TF / / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE /11 kv area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF /0.40 TF / / / TF / / TF / / TF / / TF / / TF / /

14 TYPE /1.1 kv 13 TRAILING CABLES Type /11 kv Copper Screened Three-core Cables, Central Pilot Core Hand Held Boring Machines and Drills General Underground Coal Mining Construction Conductors Tinned annealed copper wires to AS/NZS 1125:2001 and AS/NZS 1802:2003 Conductor screen Semi-conductive thermosetting compound Ethylene propylene rubber R-EP-90 to AS/NZS 3808 screen Semi-conductive thermosetting compound and tinned copper/polyamide braid to AS/NZS 1802:2003 Cradle separator Semi-conductive thermosetting compound and EPR covered Pilot Core (grey) to AS/NZS 1802:2003 Cable assembly Jacket Operating temp Cable tests AS/NZS 1802:2003 Marking Core ID FEATURES Crush resistant central cradle construction Flexible EPR insulation Three screened power conductors laid up with right hand direction on cradle separator with central pilot conductor Thermosetting compound HD-85-PCP heavy duty oil resistant and flame retardant Minimum ambient temperature -25 C Maximum conductor temperature + 90 C Type of cable, size, manufacturer, year Red, White, Blue Short circuit safety - screened conductors/semi-conductive cradle Heavy duty jacket Oil resistant/flame retardant Rated -25 C to +90 C Specifications & Standards: AS/NZS 1802:2003, AS/NZS 1125:2001

15 TYPE area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF / / TF /

16 TYPE /1.1 kv 15 REELING AND TRAILING CABLES Type /1.1 kv Three-core Cables, Central Pilot Core Three Interstitial Earth Conductors Shuttle Cars and Pump Applications General Underground Coal Mining Construction Conductors Tinned annealed copper wires to AS/NZS 1125:2001 and AS/NZS 1802:2003 Separator Synthetic tape under insulation Ethylene propylene rubber R-EP-90 AS/NZS 3808 Earth conductors Mechanically strong earth conductors with semi-conductive elastomeric covering Cradle separator Semi-conductive thermosetting compound and EPR covered Pilot Core (grey) to AS/NZS 1802:2003 Cable assembly Three screened power conductors and three earth conductors (black) laid up with right hand direction on cradle separator with central pilot conductor Filling/covering Semi-conductive thermosetting compound to AS/NZS 1802:2003 tables 6 and 7 Reinforcing braid Jacket Operating temp Polyamide yarns Cable tests AS/NZS 1802:2003 Marking Core ID FEATURES Crush resistant central cradle construction Flexible EPR insulation Thermosetting compound HD-90-CSP extra heavy duty oil resistant and flame retardant Minimum ambient temperature -25 C Maximum conductor temperature + 90 C Type of cable, size, manufacturer, year Red, (black), White, (black), Blue, (black) Short circuit safety - screened conductors/semi-conductive cradle Reinforced radial - strengthened heavy duty jacket Oil resistant/flame retardant Rated -25 C to +90 C Specifications & Standards: AS/NZS 1802:2003, AS/NZS 1125:2001

17 TYPE area Power conductor Strand size diameter of wires Earth conductor Thickness of semi-conducting covering overall diam. mm 2 n/mm mm n/mm n/mm mm mm kg/100 m TF / /0.30 TF / / TF / / TF / /

18 TYPE /11 kv 17 TRAILING CABLES Type /11 kv Copper Screened Three-core Cables Three Interstitial Pilot Conductors General and Underground Coal Mining Construction Conductors Tinned annealed copper wires to AS/NZS 1125:2001 and AS/NZS 1802:2003 Conductor screen Semi-conductive thermosetting compound Ethylene propylene rubber R-EP-90 to AS/NZS 3808 screen Semi-conductive thermosetting compound, tinned copper/polyamide braid to AS/NZS 1802:2003 Cradle separator Semi-conductive thermosetting compound comply to AS/NZS 1802:2003 Cable assembly Jacket Reinforcing braid Jacket Operating temp Three screened power conductors and three EPR insulated (grey) and textile taped pilot conductors laid up with right hand direction on cradle separator Thermosetting compound HD-85-PCP heavy duty oil resistant and flame retardant Polyamide yarns Cable tests AS/NZS 1802:2003 Marking Core ID FEATURES Crush resistant central cradle construction Flexible EPR insulation Thermosetting compound HD-90-CSP extra heavy duty oil resistant and flame retardant Minimum ambient temperature -25 C Maximum conductor temperature + 90 C Type of cable, size, manufacturer, year Red, (grey), White, (grey), Blue, (grey) Short circuit safety - screened conductors/semi-conductive cradle Heavy duty jacket Oil resistant/flame retardant Rated -25 C to +90 C Specifications & Standards: AS/NZS 1802:2003, AS/NZS 1125:2001

19 TYPE /1.1 kv area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE /3.3 kv 18 area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF /0.40 TF / / TF / / / TF / / TF / / TF / / TF / / TF / / TF / / TF / /

20 TYPE /6.6 kv area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF /0.40 TF / / TF / / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE /11 kv area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF /0.40 TF / / / TF / / TF / / TF / / TF / / TF / /

21 TYPE /11 kv 20 REELING AND TRAILING CABLES Type 241 Class 1 1.1/11 kv Three-core Cables, Central Pilot Core Three Interstitial Earth Conductors Main Feeder/Mine Power/Pump Applications Construction Conductors Tinned annealed copper wires to AS/NZS 1125:2001 and AS/NZS 1802:2003 Conductor screen Semi-conductive thermosetting compound Ethylene propylene rubber R-EP-90 to AS/NZS 3808 screen Semi-conductive thermosetting compound to AS/NZS 1802:2003 Table 7 Earth conductors Mechanically strong earth conductors with semi-conductive elastomeric covering Cradle separator Semi-conductive thermosetting compound and EPR covered Pilot Core (grey) to AS/NZS 1802:2003 Cable assembly Three screened power conductors and three earth conductors (black) laid up with right hand direction on cradle separator with central pilot conductor Filling/covering Semi-conductive thermosetting compound to AS/NZS 1802:2003 tables 6 and 7 Reinforcing braid Jacket Operating temp Polyamide yarns Cable tests AS/NZS 1802:2003 Marking Core ID FEATURES Crush resistant central cradle construction Flexible EPR insulation Thermosetting compound HD-90-CSP extra heavy duty oil resistant and flame retardant Minimum ambient temperature -25 C Maximum conductor temperature + 90 C Type of cable, size, manufacturer, year Red, (black), White, (black), Blue, (black) Short circuit safety - screened conductors/semi-conductive cradle Reinforced radial-strengthened heavy duty jacket Oil resistant/flame retardant Rated -25 C to +90 C Specifications & Standards: AS/NZS 1802:2003, AS/NZS 1125:2001

22 TYPE Class 1 1.1/1.1 kv area Power conductor Strand size Strand size Earth conductor Thickness of semi-conducting covering overall diam. mm 2 n/mm mm n/mm n/mm mm mm kg/100 m TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE Class 1 3.3/3.3 kv 21 area Power conductor Strand size Strand size Earth conductor Thickness of semi-conducting covering overall diam. mm 2 n/mm mm mm n/mm mm mm kg/100 m TF /0.40 TF / / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / /

23 TYPE Class 1 6.6/6.6 kv area Power conductor Strand size Strand size Earth conductor Thickness of semi-conducting covering overall diam. mm 2 n/mm mm n/mm n/mm mm mm kg/100 m TF / /0.30 TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE Class 1 11/11 kv area Power conductor Strand size Strand size Earth conductor Thickness of semi-conducting covering overall diam. mm 2 n/mm mm mm n/mm mm mm kg/100 m TF / /0.3 TF / / TF / / TF / / TF / / TF / / TF / / TF / /

24 Transforming the future mine

25 UNDERGROUND METAL AND SURFACE MINING Type 409 Copper Screened Three-core Cables Central Pilot Core General Underground Metal / Surface Mining Type 440 Copper Screened Three-core Cables Interstitial Pilot Conductors Power to Machinery and Equipment Type 441 Three-core Cables Central Pilot Core / Interstitial Earth Conductors Trailing / Draglines / Shovels / Drills / Reeling Type450 Copper Screened Three-core Cables Two Earth and One Pilot Interstitial Conductors Dragline, Shovel, Drill Cable and Reeling 24 Type 455 Three-core Cables Two Earth and One Pilot Interstitial Conductors Stacker / Reclamation

26 TYPE /22 kv TRAILING CABLES Type 409 Class 2 1.1/22 kv Copper Screened Three-core Cables, Central Pilot Core Underground Metal and Surface Mining Construction Conductors Tinned annealed copper wires to AS/NZS 1125:2001 and AS/NZS 2802:2000 Conductor screen Semi-conductive tape plus thermosetting compound Ethylene propylene rubber R-EP-90 to AS/NZS 3808 screen Semi-conductive thermosetting compound, tape, tinned copper/polyamide braid to AS/NZS Pilot core 1.5mm 2 Cradle separator Semi-conductive thermosetting compound and EPR covered Pilot Core (grey) to AS/NZS 2802:2000 Cable assembly Jacket Operating temp Cable tests AS/NZS 2802:2000 Marking Core ID FEATURES Crush resistant central cradle construction Flexible EPR insulation Three screened power conductors laid up with right hand direction on cradle separator with central pilot conductor Thermosetting compound HD-85-PCP heavy duty oil resistant and flame retardant Minimum ambient temperature -25 C Maximum conductor temperature + 90 C Type of cable, size, manufacturer, year Red, White, Blue Short circuit safety - screened conductors/semi-conductive cradle Heavy duty jacket Oil resistant/flame retardant Rated -25 C to +90 C Specifications & Standards: AS/NZS 2802:2000, AS/NZS 1125:2001

27 TYPE Class 2 1.1/1.1 kv area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE Class 2 3.3/3.3 kv 26 area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF /0.40 TF / / TF / / / TF / / TF / / TF / / TF / / TF / / TF / / TF / /

28 TYPE Class 2 6.6/6.6 kv area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF /0.40 TF / / TF / / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE Class 2 11/11 kv area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF /0.40 TF / / / TF / / TF / / TF / / TF / / TF / / TYPE Class 2 22/22 kv 27 area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF / /0.40 TF /

29 TYPE /22 kv 28 TRAILING CABLES Type 440 Class 2 1.1/22 kv Copper Screened Three-core Cables Three Interstitial Pilot Conductors Power to Machinery and Equipment Applications Construction Conductors Tinned annealed copper wires to AS/NZS 1125:2001 and AS/NZS 2802:2000 Conductor screen Semi-conductive thermosetting compound Ethylene propylene rubber R-EP-90 to AS/NZS 3808 screen Semi-conductive thermosetting compound, tinned copper/polyamide braid to AS/NZS 2802:2000 Cradle separator Semi-conductive thermosetting compound comply to AS/NZS 2802:2000 Cable assembly Jacket Operating temp Cable tests AS/NZS 2802:2000 Marking Core ID FEATURES Crush resistant central cradle construction Flexible EPR insulation Three screened power conductors and three EPR insulated (grey) and textile taped pilot conductors laid up with right hand direction on cradle separator Thermosetting compound HD-85-PCP heavy duty oil resistant and flame retardant Minimum ambient temperature -25 C Maximum conductor temperature + 90 C Type of cable, size, manufacturer, year Red, (grey), White, (grey), Blue, (grey) Short circuit safety - screened conductors/semi-conductive cradle Heavy duty jacket Oil resistant/flame retardant Rated -25 C to +90 C Specifications & Standards: AS/NZS 2802:2000, AS/NZS 1125:2001

30 TYPE Class 2 1.1/1.1 kv area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE Class 2 3.3/3.3 kv area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF /0.40 TF / / TF / / / TF / / TF / / TF / / TF / / TF / / TF / / TF / /

31 TYPE Class 2 6.6/6.6 kv area Strand size Power conductor siam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF /0.40 TF / / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE Class 2 11/11 kv area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF /0.40 TF / / / TF / / TF / / TF / / TF / / TF / / TYPE Class 2 22/22 kv 30 area Strand size Power conductor diam. over insulation Size Core screen Area of each screen overall diameter mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF / /0.40 TF /

32 TYPE /22 kv 31 REELING AND TRAILING CABLES Type 441 Class / 22 kv Three-core Cables Central Pilot Core Three Interstitial Earth Conductors Trailing / Draglines / Shovels / Drills / Reeling Applications Construction Conductors Tinned annealed copper wires to AS/NZS 1125:2001 and AS/NZS 2802:2000 Conductor screen Semi-conductive thermosetting compound Ethylene propylene rubber R-EP-90 and XR-EP-90 AS/NZS 3808 screen Semi-conductive thermosetting compound to AS/NZS 2802:2000 Earth conductors Mechanically strong earth conductors with semi-conductive elastomeric covering Cradle separator Semi-conductive thermosetting compound and EPR covered Pilot Core (grey) to AS/NZS 2802:2000 Cable assembly Three screened power conductors and three earth conductors (black) laid up with right hand direction on cradle separator with central pilot conductors Filling/covering Semi-conductive thermosetting compound to AS/NZS 2802:2000 tables 6 and 7 Reinforcing braid Jacket Operating temp Polyamide yarns Cable tests AS/NZS 2802:2000 Marking Core ID FEATURES Crush resistant central cradle construction Flexible EPR insulation Thermosetting compound HD-90-CSP heavy duty oil resistant and flame retardant Minimum ambient temperature -25 C Maximum conductor temperature + 90 C Type of cable, size, manufacturer, year "1 ONE, (black), 2 TWO, (black), 3 THREE, (black)" Short circuit safety - interstitial earth conductors/semi-conductive cradle Reinforced radial-strengthened heavy duty jacket Oil resistant/flame retardant Rated -25 C to +90 C Specifications & Standards: AS/NZS 2802:2000, AS/NZS 1125:2001

33 TYPE Class 2 1.1/1.1 kv area Strand size Power conductor diam. over insulation Strand size Earth conductor Nom. conduct. area overall diam. mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE Class 1 3.3/3.3 kv 32 area Strand size Power conductor diam. over insulation Strand size Earth conductor Nom. conduct. area overall diam. mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / /

34 TYPE Class 1 6.6/6.6 kv area Strand size Power conductor diam. over insulation Strand size Earth conductor Nom. conduct. area overall diam. mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF /0.40 TF / / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE Class 1 11/11 kv area Strand size Power conductor diam. over insulation Strand size Earth conductor Nom. conduct. area overall diam. mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF /0.40 TF / / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE Class 1 22/22 kv 33 area Strand size Power conductor diam. over insulation Strand size Earth conductor Nom. conduct. area overall diam. mm 2 n/mm mm mm n/mm mm 2 mm mm kg/100 m TF /0.40 TF / / / TF / / TF / / TF / / TF / / TF / /

35 TYPE /33 kv 34 REELING AND TRAILING CABLES Type 450 Class 1 3.3/33 kv Copper Screened Three-core Cables Two Earth and One Pilot Interstitial Conductors Dragline/Shovel/Drills/Reeling Applications Construction Conductors Tinned annealed copper wires to AS/NZS 1125:2001 and AS/NZS 2802:2000 Conductor screen Semi-conductive thermosetting compound Ethylene propylene rubber XR-EP-90 to AS/NZS 3808 screen Semi-conductive thermosetting compound, tinned copper/polyamide braid to AS/NZS 2802: Earth conductors Cable assembly Inner jacket Reinforcing braid Outer jacket Operating temp Cable tests AS/NZS 2802:2000 Marking Core ID FEATURES High grade flexible EPR conductors Mechanically strong earth conductors with semi-conductive elastomeric covering Three screened power conductors, two Earth conductors (black) and one insulated Pilot conductor (grey) laid up in right hand direction with Elastomeric centre filler Thermosetting compound HD-85-CSP extra heavy duty oil resistant and flame retardant Open polyamide braid between Inner and Outer Jacket Thermosetting compound HD-85-PCP extra heavy duty oil resistant and flame retardant Minimum ambient temperature -25 C Maximum conductor temperature + 90 C Type of cable, size, manufacturer, year, type of insulation and jacket Red, (black), White, (black), Blue, (grey) Short circuit safety/screened power conductors/interstitial earth conductors Interstitial pilot conductor Reinforced radial-strengthened heavy duty jacket Oil resistant/flame retardant Rated -25 C to +90 C Specifications & Standards: AS/NZS 2802:2000, AS/NZS 1125:2001

36 TYPE Class 1 3.3/3.3 kv area Strand size Power conductor Core screen Earth / pilot conductor diam. over insulation Size Area of each screen Strand Size Covering overall diam. mm 2 n/mm mm mm n/mm mm 2 n/mm mm mm mm kg/100 m TF / / / TF / / / TF / / / TF / / / TF / / / TF / / / TF / / / TF / / / TF / / / TF / / / TYPE Class 1 6.6/6.6 kv area Strand size TF /0.40 Power conductor Core screen Earth / pilot conductor diam. over insulation Size Area of each screen Strand size Covering overall diam. mm 2 n/mm mm mm n/mm mm 2 n/mm mm mm mm kg/100 m / / TF / / / TF / / / TF / / / TF / / / TF / / / TF / / / TF / / / TF / / / TF / / /

37 TYPE Class 1 11/11 kv area Strand size TF /0.40 Power conductor Core screen Earth / pilot conductor diam. over insulation Size Area of each screen Strand size Thickness of EPR covering overall diam. mm 2 n/mm mm mm n/mm mm 2 n/mm mm mm mm kg/100 m / / TF / / / TF / / / TF / / / TF / / / TF / / / TF / / / TF / / / TF / / / TYPE Class 1 22/22 kv area Strand size TF /0.40 Power conductor Core screen Earth / pilot conductor diam. over insulation Size Area of each screen Strand size Thickness of EPR covering overall diam. mm 2 n/mm mm mm n/mm mm 2 n/mm mm mm mm kg/100 m / /0.30 TF / / / TF / / / TF / / / TF / / / TF / / / TYPE Class 1 33/33 kv 36 area Strand size TF /0.40 Power conductor Core screen Earth / pilot conductor diam. over insulation Size Area of each screen Strand size Thickness of EPR covering overall diam. mm 2 n/mm mm mm n/mm mm 2 n/mm mm mm mm kg/100 m 34.1 TF / / / / TF / /

38 TYPE /33 kv 37 REELING AND TRAILING CABLES Type 455 Class 1 3.3/33 kv Three-core Cables Two Earth and One Pilot Interstitial Conductors Stacker/Reclamation Applications Construction Conductors Tinned annealed copper wires to AS/NZS 1125:2001 and AS/NZS 2802:2000 Conductor screen Semi-conductive thermosetting compound Ethylene propylene rubber XR-EP-90 AS/NZS 3808 screen Semi-conductive thermosetting compound to AS/NZS 2802:2000 Earth conductors Cable assembly Mechanically strong earth conductors with semi-conductive elastomeric covering Three screened power conductors, two Earth (black) and one Pilot conductor (grey) laid up in right hand direction Filling/covering Semi-conductive thermosetting compound to AS/NZS 2802:2000 tables 6 and 7 Reinforcing braid Jacket Operating temp Open polyamide braid Cable tests AS/NZS 2802:2000 Marking Core ID FEATURES High grade flexible EPR conductors Thermosetting compound XHD-90-CSP extra heavy duty oil resistant and flame retardant Minimum ambient temperature -25 C Maximum conductor temperature + 90 C Type of cable, size, manufacturer, year, type of insulation and jacket Red, (black), White, (black), Blue, (grey) Short circuit safety - interstitial earth conductors/semi-conductive inner sheath Interstitial pilot conductor Reinforced radial-strengthened heavy duty jacket Oil resistant/flame retardant Rated -25 C to +90 C Specifications & Standards: AS/NZS 2802:2000, AS/NZS 1125:2001

39 TYPE Class 1 3.3/3.3 kv area Strand size Power conductor diam. over insulation Earth / pilot conductor Size Thickness of EPR covering overall diam. mm 2 n/mm mm mm n/mm mm mm mm kg/100 m TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE Class 1 6.6/6.6 kv area Strand size Power conductor diam. over insulation Earth / pilot conductor Size Thickness of EPR covering overall diam. mm 2 n/mm mm mm n/mm mm mm mm kg/100 m TF /0.40 TF / / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / /

40 TYPE Class 1 11/11 kv area Strand size Power conductor diam. over insulation Earth / pilot conductor Size Thickness of EPR covering overall diam. mm 2 n/mm mm mm n/mm mm mm mm kg/100 m TF /0.40 TF / / TF / / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE Class 1 22/22 kv area Strand size Power conductor diam. over insulation Earth / pilot conductor Size Thickness of EPR covering overall diam. mm 2 n/mm mm mm n/mm mm mm mm kg/100 m TF / /0.30 TF / / TF / / TF / / TF / / TF / / TF / / TF / / TF / / TYPE Class 1 33/33 kv 39 area Strand size Power conductor diam. over insulation Earth / pilot conductor Size Thickness of EPR covering overall diam. mm 2 n/mm mm mm n/mm mm mm mm kg/100 m TF / /0.30 TF / / TF / / TF / / TF / / TF / / TF / /

41 Cutting edge machine cables

42 MACHINE CABLES Type 1 Machine Cables 1.1 kv -30C to +90C V-90 PVC Insulated and 5V-90 Type 2S Machine Cables 1.1 kv -30C to +90C Collectively or Individually Screened AS TXLPE Insulated PVC Bedded GSW Serve Wire Armoured Cable / PVC 0.6 to 1 kv -5C to +90C 41

43 TYPE 1 1.1/1.1 kv 42 MACHINE CABLES Type 1 1.1/1.1 kv V-90 PVC Insulated and 5V-90 ed Individually Screened Machine Cables, Non Mobile or Fixed Apparatus Control Boxes and Motors Construction Conductors Colour of sheath Flexible tinned copper conductor to AS/NZS 1125 Dimensions of cables comply with Table 1a, 1b Black or Transparent Special PVC compound type V-90 acc. To AS/NZS 3808, AS/NZS screen Fillers Braid made of 0.2mm tinned copper wires, coverage min 80%. A polyester tape may be applied over and under the screen Non-hygroscopic Covering Special PVC compound type 5V-90 to AS/NZS 3808, AS/NZS 1660 Operating temp Cable tests AS/NZS 1125, AS/NZS 3808 Marking Core ID FEATURES Special flexible PVC Short circuit safety - earth screened conductors Resistant to chemical attack Rated -30 C to +90 C Minimum ambient temperature -30 C Maximum conductor temperature + 90 C Type of cable, size, manufacturer, year Black - "1 ONE, 2 TWO, 3 THREE" Specifications & Standards: AS/NZS 1972, AS/NZS 1125, AS/NZS 3808

44 TYPE 1 Number of conductor Cross section of conductor Maximum dia. of wires in conductor of insulation of sheath. overall diameter. net weight of cables Maximum conductor resistance at temperature 20 0 C n/mm 2 mm mm mm mm mm kg/km Ω/km TF-1-3x2.5-IS TF-1-3x4-IS

45 TYPE 2S (IS) 1.2 kv 44 MACHINE CABLES Type 2S 1.2 kv Flexible Multi-Core Individually Screened Machine Cables, Non Mobile or Fixed Apparatus Construction Conductors Flexible tinned annealed copper wires to AS/NZS 1125 Ethylene propylene compound Type R-EP-90 to AS/NZS 3808 Screen Outer sheath Cable tests AS/NZS 1972: 2006 Marking Individual and collective braid of tinned copper wire and nylon yarns, covering minimum 80% under screen separator of polyester tape Thermosetting synthetic CPE compound equivalent HD-90-CPE, heavy duty, oil resistant and flame retardant Colour Black to AS/NZS 3808 Type of cable, year, size, metric scale Core ID 1 ONE, 2 TWO, 3 THREE identification in accordance with AS 1979 FEATURES Flexible EPR insulation Short circuit safety - individually and collectively screened conductors Oil resistant/flame retardant Rated -30 C to +90 C Specifications & Standards: AS/NZS 1972: 2006

46 TYPE 2S Product code Number of cores TF-2S-02x16-IS 2 TF-2S-03x16-IS 3 TF-2S-04x16-IS 4 TF-2S-06x16-IS 6 TF-2S-02x25-IS 2 Power conductor strand size Thickness of insulation Type of screen n mm mm mm Individually 1.8 TF-2S-03x25-IS Individually TF-2S-04x25-IS TF-2S-06x25-IS TF-2S-02x35-IS 2 TF-2S-03x35-IS 3 TF-2S-04x35-IS 4 TF-2S-02x50-IS Individually 1.8 TF-2S-03x50-IS Individually 1.9 TF-2S-04x50-IS TF-2S-02x70-IS 2 TF-2S-03x70-IS Individually 2.0 TF-2S-04x70-IS TF-2S-02x95-IS 2 TF-2S-03x95-IS Individually 2.2 TF-2S-04x95-IS

47 TYPE 2S Product code Number of cores TF-2S-02x1.5-IS 2 TF-2S-03x1.5-IS 3 TF-2S-04x1.5-IS 4 TF-2S-06x1.5-IS 6 TF-2S-16x1.5-IS 16 TF-2S-30x1.5-IS 30 TF-2S-02x2.5-IS 2 TF-2S-03x2.5-IS 3 TF-2S-04x2.5-IS 4 TF-2S-06x2.5-IS 6 TF-2S-02x4.0-IS 2 TF-2S-03x4.0-IS 3 TF-2S-04x4.0-IS 4 TF-2S-06x4.0-IS 6 TF-2S-02x6.0-IS 2 TF-2S-03x6.0-IS 3 TF-2S-04x6.0-IS 4 TF-2S-06x6.0-IS 6 TF-2S-02x10-IS 2 TF-2S-03x10-IS 3 TF-2S-04x10-IS 4 TF-2S-06x10-IS 6 Size Type of screen n mm 2 mm mm Individually Individually Individually Individually Individually 1.8 Individually Screened (IS) Electrical Properties 46 Size Max. resistance Rating current capacitance DC 20 C AC 90 C 2-core 3-core 4-core 6-core mm 2 Ω/km μf/km A

48 Size Inductance Reactance Impedance at 90 C 2-core 3-core 4-core 6-core 2-core 3-core 4-core 6-core 2-core 3-core 4-core 6-core mm 2 mh/km Ω/km Ω/km

49 TYPE 2S (CS) 1.2 kv MACHINE CABLES Type 2S 1.2 kv Flexible Multi-Core Collectively Screened Machine Cables, Non Mobile or Fixed Apparatus Construction Conductors Flexible tinned annealed copper wires to AS/NZS 1125 Ethylene propylene compound Type R-EP-90 to AS/NZS 3808 Screen Outer sheath Cable tests AS/NZS 1972: 2006 Marking Individual and collective braid of tinned copper wire and nylon yarns, covering minimum 80% under screen separator of polyester tape Thermosetting synthetic CPE compound equivalent HD-90-CPE, heavy duty, oil resistant and flame retardant Colour Black to AS/NZS 3808 Type of cable, year, size, metric scale Core ID 1 ONE, 2 TWO, 3 THREE identification in accordance with AS 1979 FEATURES Flexible EPR insulation Short circuit safety - individually and collectively screened conductors Oil resistant/flame retardant Rated -30 C to +90 C Specifications & Standards: AS/NZS 1972:

50 TYPE 2S Product code Number of cores TF-2S-02x1.5-CS 2 TF-2S-03x1.5-CS 3 TF-2S-04x1.5-CS 4 TF-2S-06x1.5-CS 6 TF-2S-16x1.5-CS 16 TF-2S-30x1.5-CS 30 TF-2S-02x2.5-CS 2 TF-2S-03x2.5-CS 3 TF-2S-04x2.5-CS 4 TF-2S-06x2.5-CS 6 TF-2S-02x4.0-CS 2 TF-2S-03x4.0-CS 3 TF-2S-04x4.0-CS 4 TF-2S-06x4.0-CS 6 TF-2S-02x6.0-CS 2 TF-2S-03x6.0-CS 3 TF-2S-04x6.0-CS 4 TF-2S-06x6.0-CS 6 TF-2S-02x10-CS 2 TF-2S-03x10-CS 3 TF-2S-04x10-CS 4 TF-2S-06x10-CS 6 Power conductor strand size Thickness of insulation Type of screen n mm mm mm Collective Collective Collective Collective Collective

51 TYPE 2S Product code Number of cores TF-2S-02x16-CS 2 TF-2S-03x16-CS 3 TF-2S-04x16-CS 4 TF-2S-06x16-CS 6 TF-2S-02x25-CS 2 Individually Screened (CS) Electrical Properties Size Type of screen n mm 2 mm mm Collective 1.8 TF-2S-03x25-CS Collective TF-2S-04x25-CS TF-2S-06x25-CS TF-2S-02x35-CS 2 TF-2S-03x35-CS 3 TF-2S-04x35-CS 4 TF-2S-02x50-CS Collective 1.8 TF-2S-03x50-CS Collective 1.9 TF-2S-04x50-CS TF-2S-02x70-CS 2 TF-2S-03x70-CS Collective 2.0 TF-2S-04x70-CS TF-2S-02x95-CS 2 TF-2S-03x95-CS Collective 2.2 TF-2S-04x95-CS Size Max. resistance Rating current Capacitance DC 20 C AC 90 C 2-core 3-core 4-core 6-core mm 2 Ω/km μf/km A

52 Size Inductance Reactance Impedance at 90 C 2-core 3-core 4-core 6-core 2-core 3-core 4-core 6-core 2-core 3-core 4-core 6-core mm 2 mh/km Ω/km Ω/km

53 TYPE XLPE SWA PVC 0.6/1 kv 52 XLPE INSULATED PVC BEDDED 0.6 to 1 kv GSW Armoured Cable/PVC Power Networks, Outdoors, Underground and Conduit Construction Conductors Circular Stranded and circular compacted stranded conductor class 2 (RM and RMC) to AS/NZS 1125 Cross-linked polyethylene XLPE type X-90 to AS/NZS 3808 Inner sheath Armour PVC compound type 5V-90 acc to AS/NZS 3808; colour white Galvanized steel wires helically served Outer sheath PVC UV resistant compound type 5V-90 to AS/NZS 3808; colour orange RAL 2003 Min. bend radius Core ID FEATURES Flexible PVC insulation Crush resistant core Resistant to chemical attack UV resistant Armored - cut through resistant Rated +90 C Specifications & Standards: AS/NZS X D multi-core cables, D = Overall diameter Short Circuit Temp: 250C 2 Core + Earth - Red, Black, Green/Yellow

54 TYPE XLPE SWA PVC Number and crosssectional area of conductor insulation inner sheath diameter armour wire outer sheath overall diameter cable weight Max conductor resistance at 20 o C n x mm 2 mm mm mm mm mm kg/km Ω/km TF-51-XLPE-2x1.5-SWA 2x1.5RM+1.5RM 0.7/ /12.1 TF-51-XLPE-2x2.5-SWA 2x2.5RM+2.5RM 0.7/ /7.41 TF-51-XLPE-2x04-SWA 2x4RM+2.5RM 0.7/ /7.41 TF-51-XLPE-2x06-SWA 2x6RMC+2.5RM 0.7/ /7.41 TF-51-XLPE-2x10-SWA 2x10RMC+4RM 0.7/ /4.61 TF-51-XLPE-2x16-SWA 2x16RMC+6RMC 0.7/ /3.08 TF-51-XLPE-2x25-SWA 2x25RMC+6RMC 0.9/ /3.08 TF-51-XLPE-2x35-SWA 2x35RMC+10RMC 0.9/ /1.83 TF-51-XLPE-2x50-SWA 2x50RM+16RMC 1.0/ /1.15 TF-51-XLPE-2x70-SWA 2x70RMC+25RMC 1.1/ /0.727 TF-51-XLPE-2x90-SWA 2x95RMC+25RMC 1.1/ /0.727 TF-51-XLPE-2x120-SWA 2x120RMC+35RMC 1.2/ / Number and crosssectional area of conductor insulation inner sheath diameter armour wire outer sheath overall diameter cable weight Max conductor resistance at 20 o C n x mm 2 mm mm mm mm mm kg/km Ω/km TF-51-XLPE-3x1.5-SWA 3x1.5RM+1.5RM 0.7/ /12.1 TF-51-XLPE-3x2.5-SWA 3x2.5RM+2.5RM 0.7/ /7.41 TF-51-XLPE-3x04-SWA 3x4RM+2.5RM 0.7/ /7.41 TF-51-XLPE-3x06-SWA 3x6RMC+2.5RM 0.7/ /7.41 TF-51-XLPE-3x10-SWA 3x10RMC+4RM 0.7/ /4.61 TF-51-XLPE-3x16-SWA 3x16RMC+6RMC 0.7/ /3.08 TF-51-XLPE-3x25-SWA 3x25RMC+6RMC 0.9/ /3.08 TF-51-XLPE-3x35-SWA 3x35RMC+10RMC 0.9/ /1.83 TF-51-XLPE-3x50-SWA 3x50RM+16RMC 1.0/ /1.15 TF-51-XLPE-3x70-SWA 3x70RMC+25RMC 1.1/ /0.727 TF-51-XLPE-3x95-SWA 3x95RMC+25RMC 1.1/ /0.727 TF-51-XLPE-3x120-SWA 3x120RMC+35RMC 1.2/ /0.524 TF-51-XLPE-3x150-SWA 3x150RMC+50RMC 1.4/ /0.387 TF-51-XLPE-3x185-SWA 3x185RMC+70RMC 1.6/ /0.268 TF-51-XLPE-3x240-SWA 3x240RMC+95RMC 1.7/ /0.193 TF-51-XLPE-3x300-SWA 3x300RMC+120RMC 1.8/ /0.153

55 TYPE XLPE SWA PVC Number and crosssectional area of conductor insulation inner sheath diameter armour wire outer sheath overall diameter cable weight Max conductor resistance at 20 o C n x mm 2 mm mm mm mm mm kg/km Ω/km TF-51-XLPE-4x1.5-SWA 4x1.5RM+1.5RM 0.7/ /12.1 TF-51-XLPE-4x2.5-SWA 4x2.5RM+2.5RM 0.7/ /7.41 TF-51-XLPE-4x04-SWA 4x4RM+2.5RM 0.7/ /7.41 TF-51-XLPE-4x06-SWA 4x6RMC+2.5RM 0.7/ /7.41 TF-51-XLPE-4x10-SWA 4x10RMC+4RM 0.7/ /4.61 TF-51-XLPE-4x16-SWA 4x16RMC+6RMC 0.7/ /3.08 TF-51-XLPE-4x25-SWA 4x25RMC+6RMC 0.9/ /3.08 TF-51-XLPE-4x35-SWA 4x35RMC+10RMC 0.9/ /0.268 TF-51-XLPE-4x50-SWA 4x50RM+16RMC 1.0/ /1.15 TF-51-XLPE-4x70-SWA 4x70RMC+25RMC 1.1/ /0.727 TF-51-XLPE-4x95-SWA 4x95RMC+25RMC 1.1/ /0.727 TF-51-XLPE-4x120-SWA 4x120RMC+35RMC 1.2/ /0.524 TF-51-XLPE-4x150-SWA 4x150RMC+50RMC 1.4/ /0.387 TF-51-XLPE-4x185-SWA 4x185RMC+70RMC 1.6/ /0.268 TF-51-XLPE-4x240-SWA 4x240RMC+95RMC 1.7/ /0.193 TF-51-XLPE-4x300-SWA 4x300RMC+120RMC 1.8/ /

56 Leader in heavy duty industrial cables

57 TYPE EMV 0.6/1 kv 56 EMV 0.6 to 1 kv Motor power supply flexible rubber cables (VSD) Other industrial applications Construction Conductors Annealed flexible stranded bare copper Class 6 or 5 to IEC 60228, HD 383 Separator A suitable tape separator between the conductor and insulation Ethylene-propylene rubber (EPR) type 3GI3 in accordance to DIN VDE 0207 p. 20 Circuit indetification Assembly Internal jacket Concentric screen white, blue, red, earth: green-yellow 3 power cores + one earth (for 4mm 2 ) or 3 power cores and 3 earth cores laid up around rubber filler wrapped of polyester tape Ethylene propylene thermosetting compound type EI 4 acc. DIN VDE 0207 part 20. Color natural The wrap aluminium tape (one side polyester covered) + tinned copper wires (diameter 0.25, 0.30, 0.40 mm) applied in the form of braid. Covering min. 80% Outer jacket A synthetic thermosetting compound type 5GM3 acc. DIN VDE 0207 part 21 Colour of outer jacket Black Flame propagation IEC :2004, EN :2004 FEATURES Special composite concentric screen Flame retardant Temperature range for mobile application -30 to +90 C, for fixed -40 C to +90 C Heat, ozone, oil resistance Ink jet printed for easy identification 500m on drums. Other forms of packing and delivery are available on request Specifications & Standards: DIN VDE 0250 p. 812

58 TYPE EMV 0.6/1 kv Size Stranding of power conductor Stranding of earth conductor diameter under screen outer diameter. weight of cable mm mm kg/km 3x / / x6+3x / / x6 76/ x10+3x / / x16+3x / / x25+3x4 777/ / x35+3x6 1094/ / x50+3x / / x70+3x / / x95+3x / / x120+3x / / x150+3x / /

59 TYPE SINGLE CONDUCTOR POWER CABLE 0.6/1 kv, 110 C SINGLE CONDUCTOR POWER CABLE 0.6 to 1kV Wiring machine, screened, rubber insulated and sheathed cable Construction Conductors Annealed plain copper conductor Class 6 to IEC Separator Outer sheath Colour of outer sheath If needed a suitable tape separator between the conductor and insulation EPR thermosetting compound type R-E-110 Halogen free, low smoke thermosetting compound E-110-R Orange Standard marking Ink jet printed. For example: TF Kable 3 R-E-110 1x95 mm 2 0.6/1kV 2012 FEATURES Halogen free, heat resistance Oil, chemical resistance, flame retardant UV and weather resistant Temperature range -25 C to +110 C Ink jet printed for easy identification 1000m on drums. Other forms of packing and delivery are available on request Specifications & Standards: AS/NZS , IEC 60228, AS/NZS 3808, AS/NZS3008, AS/NZS3008, AS/NZS , AS/NZS , IEC , IEC , IEC

60 TYPE SINGLE CONDUCTOR POWER CABLE Number and crosssection area Stranding O.D. over insulation Overall diameter Short circuit current. weight Min. Max. 1 sec. 0.1 sec. Current rating (Amps) mm 2 n x mm mm mm kg/km ka A 1x16 470x x25 726x x x x x x x x x x x x x x x x x x x x x x x x x

61 TYPE H07RN-F 450/750 V SUB 60 H07RN-F SUB 450 to 750 V Flexible rubber insulated and sheathed cables Construction Conductors Annealed flexible stranded tin coated class 5 to EN Separator A suitable tape separator between the conductor and insulation Ethylene-propylene rubber (EPR) type EI4 in acc. to EN Circuit identification Twin 3-core 4-core 5-core Above 5-core Internal jacket Colour coding of power conductors comply to HD 308, DIN VDE Blue and brown Green-yellow, blue, brown Green-yellow, brown, black, grey Green-yellow, blue, brown black, grey Green-yellow, other cores black with white numbering A synthetic thermosetting compound type EM3 in acc. to EN (above 2, 3, 4, 5 x 6mm 2 and 1 x 50mm 2 ) Outer jacket A synthetic thermosetting compound type EM2 in acc. to EN Colour of outer jacket Black or other colours can be provided Flame propagation EN :2004, IEC :2004 FEATURES Excellent flexibility Flame retardant Temperature range -25 C to +90 C For fixed protected installation -40 C to +90 C UV, sunlight, ozone and oil resistant Ink jest printed for easy identification 1000m on drums. Other forms of packing and delivery are available on request Specifications & Standards: EN , BBJ HAR

62 TYPE H07RN-F 450/750 V Size Number x maximum diameter of wire of insulation Single of jacket Double layer Internal Outer. O.D. of cable Voltage drop. weight of cable Maximum conductor resistance at 20 C n x mm 2 mm mm mm mm mm mm V/A/km kg/km Ω/km 1x1.5 28x x2.5 45x x4 51x x6 76x x10 74x x16 116x x25 180x x35 254x x50 364x x70 514x x95 684x x x x x x x x x x x x x x x x x x1 29x x1.5 28x x2.5 45x x x x4 51x x6 76x x10 74x x16 116x x25 180x x1 29x x1.5 28x x2.5 45x x4 51x x6 76x x10 74x x16 116x x25 180x x35 254x x50 364x x70 514x

63 TYPE H07RN-F 450/750 V Size Number x maximum diameter of wire of insulation Single of jacket Double layer Internal Outer. O.D. of cable Voltage drop. weight of cable Maximum conductor resistance at 20 C n x mm 2 mm mm mm mm mm mm V/A/km kg/km Ω/km 3x95 684x x x x x x x x x x x x1 29x x1.5 28x x2.5 45x x4 51x x6 76x x10 74x x16 116x x25 180x x35 254x x50 364x x70 514x x95 684x x x x x x x x x x1 29x x1.5 28x x2.5 45x x4 51x x6 76x x10 74x x16 116x x25 180x x35 254x x50 364x x70 514x x95 684x x1.5 28x x2.5 45x x4 51x

64 TYPE H07RN-F 450/750 V Size Number x maximum diameter of wire of insulation Single of jacket Double layer Internal Outer. O.D. of cable Voltage drop. weight of cable Maximum conductor resistance at 20 C n x mm 2 mm mm mm mm mm mm V/A/km kg/km Ω/km 7x1.5 28x x2.5 45x x4 51x x1.5 28x x2.5 45x x4 51x x1.5 28x x2.5 45x x1.5 28x x2.5 45x x4 51x x1.5 28x x2.5 45x x4 51x x1.5 28x x2.5 45x x2.5 45x x1.5 28x x2.5 45x x1.5 28x x2.5 45x x4 51x x1.5 28x x0.5 45x x1.5 28x x2.5 45x x1.5 28x x2.5 45x x1.5 28x x2.5 45x x2.5 45x

65 TYPE H07RN-F 450/750 V Current rating in free air at air temperature of 30 C and conductor temperature of 85 C Cross section Single core Two cores Three cores Four cores Five cores Seven cores mm 2 A Correction factor for ambient temperature Temperature of air C Correct factor

66 TYPE NSGAFÖU 0.6/1, 1.8/3, 3.6/6 kv SINGLE CONDUCTOR RUBBER INSULATED AND SHEATED FLEXIBLE POWER CABLES 0.6/1, 1.8/3, 3.6/6 kv Heavy-duty flexible single core power cables for mobile and fixed applications Other industrial applications Construction Conductors Annealed flexible stranded tin coated or bare copper class 5 to IEC 60228, HD 383 Separator A suitable tape between the conductor and insulation Ethylene-propylene rubber (EPR) type 3GI3 to DIN VDE 0207 p. 20 Outer jacket A synthetic thermosetting compound type 5GM3 to DIN VDE 0207 p. 21 Colour of outer jacket FEATURES Excellent flexibility Water resistant and flame retardant Black or other colours can be provided Temperature range -25 C to +90 C. For fixed installation lowest temperature is -40 C UV, sunlight, ozone and oil resistant Ink jet printed for easy indetification 1000m on drums. Other forms of packing and delivery are available on request Specifications & Standards: DIN VDE 0250 p

67 TYPE NSGAFÖU 0.6/1, 1.8/3, 3.6/6 kv 66 Number and cross-sectional area of conductor of insulation of sheath. overall diameter. net weight of cables Current-carrying capacity at 30 C in air mm 2 mm mm mm kg/km A 0.6/1 kv 1x x x x x x x x x x x x x x x x x400** /3 kv 1x x x x x x x x x x x x x x x x x400** x500** /6 kv 1x1** x x x x x

68 TYPE NSGAFÖU 0.6/1, 1.8/3, 3.6/6 kv Number and cross-sectional area of conductor of insulation of sheath. overall diameter. net weight of cables Current-carrying capacity at 30 C in air mm 2 mm mm mm kg/km A 0.6/1 kv 1x x x x x x x x x x240** x400** **Based on DIN VDE 0250 p. 602 as (N)SGAFOU 67

69 TYPE 07RN-F/CY 450/750 V 68 RUBBER INSULATED AND JACKETED CABLES WITH CONCENTRIC TINNED COPPER SCREEN 450/750 V In mines, quarries and industrial areas, indoors and outdoors, for higher mechanical stresses as flexible cable and as trailing cable for mobile current consumers Other industrial applications Construction Conductors Annealed flexible stranded tin coated class 5 to IEC Separator A suitable tape separator between the conductor and insulation EPR thermosetting compound exceed parameters of type EI4 in accordance to EN Circuit identification Colour coding of power conductors comply to HD 308 Internal jacket EPR thermosetting compound type EI4 in accordance to EN Concentric screen The wrap of aluminum tape (one side polyester coating) + the braid of tinned copper wires. Covering: minimum 82% Outer jacket Heavy duty thermosetting CPE compound type EM2 in accordance to EN Colour of outer jacket FEATURES Concentric copper screen between layer Flame retardant and oil resistant jacket Black Bending radius for fixed max. 10 x cable diameter, for mobile application 15 x cable diameter Temperature range -25 C to +90 C. For fixed installation lowest temperature is -30 C Ink jet printed for easy indetification 500m on drums. Other forms of packing and delivery are available on request Specifications & Standards: EN

70 TYPE 07RN-F/CY 450/750 V of jacket Size Maximum diameter of wire of insulation Single Internal Double layer Outer. O.D. of cable. weight of cable Maximum conductor resistance 20 C n x mm 2 mm mm mm mm mm mm kg/km Ω/km 5G G G G G G G

71 TYPE NSGAFÖU/CY 1.8/3.3 kv SINGLE CONDUCTOR EPR INSULATED, Cu SCREENED AND CPE SHEATHED POWER CABLES 1.8/3.3 kv Heavy-duty flexible single core power cable with concentric screen for mobile and fixed applications Other industrial applications Construction Conductors Annealed flexible stranded tin coated or bare copper class 5 to IEC 60228, HD 383 Separator A suitable tape separator between the conductor and insulation Ethylene-propylene rubber (EPR) type 3GI3 to DIN VDE 0207 p. 20 Concentric screen The braid of tinned copper wires. Covering 82% Outer jacket A synthetic thermosetting compound type 5GM3 to DIN VDE 0207 p. 21 Colour of outer jacket FEATURES Concentric copper screen between layer Flame retardant and oil resistant jacket Black or other colours can be provided Bending radius for fixed max. 10 x cable diameter, for mobile application 15 x cable diameter Temperature range -25 C to +90 C. For fixed installation lowest temperature is -30 C Ink jet printed for easy indetification 500m on drums. Other forms of packing and delivery are available on request Specifications & Standards: DIN VDE 0250 p Number and crosssectional area of conductor of insulation of sheath. overall diameter. net weight of cables Current-carrying capacity at 30 C in air Conductor resistance at 20 C mm 2 mm mm mm kg/km A Ω/km 1x x x x x

72 CABLE DRUMS SAMPLE DATA OF WOODEN CABLE DRUMS Sample data regarding wooden cable drums Type Ø D Ø D1 B L Weight (kg) 060T T T AT T T AT T AT T T T AT T T AT BT T T AT BT MT T AT BT T AT T D 1 D B L Note: Figures used are indicative and may vary due to manufacturing tolerances, so should only be used as guidance. Cable wooden drums are standardized, but we also offer special wooden drums with different dimensions on customer request.

73 PRINCIPAL ELASTOMERIC MATERIALS USED IN REELING AND TRAILING CABLES INSULATION The elastomer used for the insulation of all reeling and trailing cables to AS/NZS 1802 and AS/NZS 2802 is a compound based on ethylene propylene rubber (EPR) known in the Australian Standards as R-EP-90 or, in the case of Class 1 cables to AS/NZS 2802, as XR-EP-90, the latter being an electrically superior grade material when compared with R-EP-90 and mechanically different. Typical properties of TF Kable Ethylene Propylene Rubber (EPR) insulation A. Mechanical tests without ageing Test (per AS/NZS 1802/AS/NZS 2802) R-EP-90 Typical achieved Specified value XR-EP-90 Typical achieved Specified value 1. Tensile strength (MPa) Elongation at rupture (percent) B. Mechanical tests after ageing in air oven 1. Tensile strength (percentage of values found in unaged specimens) Elongation at rupture (percentage of values found in unaged specimens) C. Hot set test 1. Elongation under load (percent) Residual elongation after cooling (percent) D. Electrical characteristics 1.1/1.1kV 3.3/3.3kV 1. resistance constant (ki) at room temperature (GΩ.m) resistance constant (ki) at 90 C (GΩ.m) SHEATH The elastomer used for the sheathing (inner and outer) of all reeling and trailing cables to AS/NZS 1802 and AS/NZS 2802 is a compound based on heavy/extra heavy duty polychloroprene (PCP). For all cables, in addition to the requirements specified in AS/NZS 1802, the PCP compound meets the most stringent requirements applicable for XHD-85-PCP specified for Class 1 cables in AS/NZS Black PCP sheath is recommended. Typical properties of TF Kable PCP sheath 72 Test (except for D and E, per AS/NZS 1802/AS/NZS 2802) Typical Achieved All Black PCP sheaths A. Mechanical tests without ageing CSP PCP Specified value GP-85-PCP HD-85-PCP XHD-85-PCP 1. Tensile strength (MPa) Elongation at rupture (percent) Tear resistance (N/mm) B. Mechanical tests after ageing in air oven 1. Tensile strength (MPa) Elongation at rupture (percent) C. Oil immersion test 1. Tensile strength (percentage of values found in unaged specimens) Elongation at rupture (percentage of values found in unaged specimens) D. Hardness (IRHD) E. Oxygen index

74 SEMICONDUCTIVE CRADLE, EARTH COVERING AND SCREEN FOR CORE ASEMBLY The semiconductive elastomer used in the manufacture of the reeling and trailing cable cradle, the interstitial earth conductor covering (other than for Type 412) and the screen for core assembly (Types 241, 245, 275 and 441 only) is a compound based on polychloroprene (PCP) which, unlike in the case of the semiconductive materials in many imported cables, does not propagate flame and is oil and wear resistant. Typical properties of TF Kable semiconductive chlorosulphonated polyethylene (CSP) Test (except for D, per AS/NZS 1802/AS/NZS 2802) Typical Achieved Specified value A. Mechanical tests without ageing 1. Tensile strength (MPa) Elongation at rupture (percent) Permanent set (percent) 5 20 B. Mechanical tests after ageing in air oven 1. Tensile strength (MPa) Elongation at rupture (percent) C. Volume resistivity at 23 C (Ω.m) D. Oxygen index 26-73

75 RECOMMENDED LIMITS TO REELING AND TRAILING CABLE OPERATION Although TELE-FONIKA Kable cables perform satisfactorily under more severe conditions, in the interest of ensuring good service life and reliability it is recommended that the following limits be observed: TEMPERATURE Maximum continuous conductor temperature: 90 C Minimum continuous conductor temperature: -25 C TENSION Maximum continuous working tension: 0.02kN/mm 2 of total cross-sectional area of main conductors* BARREL SIZE OF REELS Often cables are reeled for storage or relocation and therefore are not energised while on the reel. The minimum diameter of the barrel of the reel, in multiples of cable overall diameter, shall be no less than: 1kV cables Reeling and Trailing, 3.3kV & above 12D 15D BENDING RADII AND CHANGES IN DIRECTION Reeling and trailing cable bending radii, in multiples of cable overall diameter, shall be not less than: Situation Cables rated 1.1/1.1kV Cables rated 3.3/3.3kV and above Fixed installation 4 6 Free flexing (not under tension) 6 10 Permanently repeating reeling At deflection sheaves or rollers Change in the cable axial direction when related to the cable drum axis, i.e. change from right angle to that parallel to the drum axis (or similar) should be avoided. Where unavoidable, the straigth section of cable between the deflection sheave or roller where change in axial direction takes place and the preceding bending point, shall be not less than 20 times the overall diameter of the cable. Same minimum straight section applies where cable is subjected to an "S" bend. 74 * Any reduced size conductors (e.g. any interstitial conductors), and screens do not effectively contribute to the strength of the cable and hence should not be included in the calculation.

76 NOTES 75 TELE-FONIKA Kable cannot be held responsible for any printing errors, and reserves the right to change the contents of the information without prior notice. All Rights Reserved TELE-FONIKA Kable Sp. z o.o. S.K.A. Edition II

77 TELE-FONIKA Kable Sp. z o.o. S.K.A. Wielicka Street No. 114, Cracow T: (+48) , (+48) , (+48) F: (+48) export@tfkable.pl

A NEW BEGINNING IN OIL & GAS. Offshore Cable Range

A NEW BEGINNING IN OIL & GAS. Offshore Cable Range A NEW BEGINNING IN OIL & GAS Offshore Cable Range 2 TABLE OF CONTENTS TELE-FONIKA Kable S.A. 2 PRODUCTION POTENTIAL 3 CABLE CODE DESIGNATION 6 BS6883/BS7917 (UKOOA) 6571 SW4 0.6/1kV Single Earthing TCu/EPR/ZH

More information

Medium voltage cables

Medium voltage cables Medium voltage cables Leading producer of cables and cable systems 2 The TELE-FONIKA Kable Group has been present on the domestic and international cable industry market for more than 25 years. A stable

More information

DURAREEL TRAILING REELING CABLE

DURAREEL TRAILING REELING CABLE Supplementary Technical Information Reeling and trailing material characteristics: A. Power core conductor Flexible strands tinned annealed copper complies with AS/NZS 1802, AS/NZS 2802, AS/NZS 1125, and

More information

CRANE, CONVEYOR, LIFT & REELING CABLES

CRANE, CONVEYOR, LIFT & REELING CABLES CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264

More information

Connecting globally. TFCrane

Connecting globally. TFCrane Connecting globally 1 Table of Contents TELE-FONIK Kable S.. 4 PPLICTION 6 dditional PramETErs 7 REELING CBLE - 0,6/1kV NSHTÖU -J/O 8 (N)SHTÖU -J + FO 15 2 3 REELING CBLE - 3,6/6kV, 6/10kV, 8,7/15kV, 12/20kV

More information

Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc.

Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc. INTRODUCTION : Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc. Rubber is still considered the preferred insulation for

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

Cable Guide for the Mining Industry. August 2016

Cable Guide for the Mining Industry. August 2016 Cable Guide for the Mining Industry August 2016 DISCLAIMER Whilst every care has been taken in the preparation of this publication, the Prysmian Group takes no responsibility for any errors and omissions.

More information

DLO. Mining Cable. Mining Cable. 2 kv

DLO. Mining Cable. Mining Cable. 2 kv 11 DLO./;DLO/346 Index1.W&C Energy Products//Premium Power

More information

Section 11 Mining Cable

Section 11 Mining Cable 11 Section 11 DLO.......................................................................... 11.1 Drill Cord...................................................................... 11.2 Type G CV Cured.................................................................

More information

Any inquiries, please feel free to contact or Caledonian

Any inquiries, please feel free to contact or Caledonian Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant)

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian Caledonian Offshore & Marine Cables BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian, established in 1978, offers one of the most complete lines of fiber and

More information

Technical Information

Technical Information Cable Code Designation A cable code of 2 letters (1. and 4.) or 4 letters is used to describe the construction. For example: 1st Letter: Insulation: B: Fire resistant tape + insulation (Halogen-free) R:

More information

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue) XLPE INSULATED AND PVC OR LOW SMOKE HALOGEN FREE (LSHF) SHEATHED CABLES Voltage Rating (Uo/U) : 00/00V, 1/0V or 00/3V Standards Complied Main Specification Materials Test Methods Flame Retardant Test Test

More information

TUNNELING POWER CABLES

TUNNELING POWER CABLES TUNNELING POWER CABLES Index 3- Type G-GC (Round) 3/C kv..................... -3 3-5 Type SHD-GC 3/C 5kV........................ -5 3-55 Type SHD-GC 3/C 5kV........................ - 3-0/0/0 Type MP-GC

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813

RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813 REELING CABLE RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813 Contents: Letter code Construction details and voltage-classes Technical data 2016 RHEYFIRM(RTS)

More information

Chemical resistance Accidental

Chemical resistance Accidental Industrial flexible cable, insulation and outer sheath in elastomer. Oil resistant, flame retardant according to IEC/EN 60332-1-2 standard. Description Application flexible cable is intended for installations

More information

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables 3 SK1_1-001.tif 4 SK1_1-003.tif SK1_1-00.tif Selection and dimensioning criteria Refer to Section 4 for further details Ü Type CORDAFLEX(SMK)

More information

XLPE Cable Systems. User s guide. rev. 2

XLPE Cable Systems. User s guide. rev. 2 XLPE Cable Systems User s guide rev. 2 C O N T E N T XLPE Cable Systems Page Page Introduction... 3 XLPE cable systems - design, installation and testing... 4 XLPE cables... Cable accessories... Installation

More information

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5 Semoflex DRUM Description Application In dry and damp rooms, explosive security areas and also outdoors for heavy-duty units such as hoisting gears, transportation systems, motorized cable reels, rail

More information

BFOU 0.6/1kV Power Cable

BFOU 0.6/1kV Power Cable BFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame resistant, fire retardant, halogen free cable for fixed installation in various electromechanical and electric equipment, emergency

More information

2011 Ver Ph: Product Catalogue. Industrial Cables Hazardous area equipment Cable termination

2011 Ver Ph: Product Catalogue. Industrial Cables Hazardous area equipment Cable termination 2011 Ver 1.1 Product Catalogue Industrial Cables Hazardous area equipment Cable termination KabEx Australia is a leading company specializing in the supply of cables, hazardous area equipment and associated

More information

TC-RHH/RHW-2 USE-2 Copper

TC-RHH/RHW-2 USE-2 Copper TC-RHH/RHW-2 USE-2 Copper XLPE Insulated, PVC Jacketed, ER; 600 V Features Standards UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

Cable category. B Multi-core cables for domestic/handheld equipment Rubber insulation PVC insulation TPE insulation 0.

Cable category. B Multi-core cables for domestic/handheld equipment Rubber insulation PVC insulation TPE insulation 0. Table 12-1: current rating Technical Tables T12 Current ratings basic table ÖLFLEX For cables with a nominal voltage of up to 1000 V and for heat-resistant cables at an ambient temperature of +30 C. You

More information

600/1000V, XLPE Insulated Cables according to IEC

600/1000V, XLPE Insulated Cables according to IEC 600/1000V, XLPE Insulated Cables according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured) Multi- core(unarmoured) Single

More information

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

LDC Pricelist. ( WEF 1st August 2017 ) POLYCAB 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured. INDUSTRIAL JELLY FLOODED COAXIAL CABLES LDC Pricelist LAN (COMPUTER) CABLES "POLYCAB" Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded

More information

FR-3S Fire Resistant Cables

FR-3S Fire Resistant Cables FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and

More information

H07RN-F TITANEX (industrial flexible)

H07RN-F TITANEX (industrial flexible) Description Application TITANEX flexible cable is intended for installations with moving equipment, electric appliances and for building sites. The cable may be rated 0,6/1 kv where the installation has

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER; SR; PR; Dir Bur; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance, Oil Resistance I and Direct Burial.

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information

LISTED. Applications. Features CORDAFLEX (SM) CORDAFLEX (SM)

LISTED. Applications. Features CORDAFLEX (SM) CORDAFLEX (SM) CORDAFLEX (SM) Portable reel cable EP insulation, dual neoprene jacket with braid reinforcement, 90 C, 600 volts Rack and pinion elevators using sheave guided cables Container crane spreader reels Timber

More information

RFOU 0.6/1kV Power Cable

RFOU 0.6/1kV Power Cable RFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame retardant halogen free power, control and lighting cable for fixed installation. Suitable for use in all conditions in a marine environment

More information

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D. DRILL CORD Synthetic Rubber Insulation 75 C, 600 Volts For use on drills and other mining equipment. For use on circuits not exceeding 600 volts at a maximum conductor temperature 75 C. 1. CONDUCTOR: Flexible,

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 350 CY VDE Registered Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed

More information

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax Introduction General Cable is a world leader in cable manufacture and one of the world s largest suppliers to the Offshore and sector. General Cable s extensive experience in the offshore market translates

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

SUBMERSIBLE PUMP CABLES

SUBMERSIBLE PUMP CABLES SUBMERSIBLE PUMP CABLES GENERAL INTRODUCTION Bahra Cables Company was established in 2008 to serve Saudi & GCC Markets. It is based in Bahra industrial city located 25km from Jeddah. Bahra Cables Factory

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable Technical Data Sheet Shielded (CY) PVC Control Cable MachFlex 375 CY Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing

More information

N C T (S) F. Insulation Rubber (EPR)

N C T (S) F. Insulation Rubber (EPR) Type Designation Cable H T P N C T (S) F Cable Type HT : High Tension Cable FC : Festoon Cable SC : Spreader Cable PNCTR : High Cable : NonShield (S) : Shield Cap Tire Rubber (CR) Rubber (EPR) F R : Flat

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

Submarine Power Cables

Submarine Power Cables Submarine Power Cables Submarine Power Cables Since decades Nexans plant in Hannover is specialised in the design, production and installation of low and medium voltage submarine power cables required

More information

Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region)

Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region) Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region) Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region) Linking the Future As the worldwide leader

More information

600/1000V, PVC Insulated Cables according to IEC

600/1000V, PVC Insulated Cables according to IEC 8 Any inquiries, please feel free to contact 600/1000V, PVC Insulated s according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured)

More information

The cables you need when you need them

The cables you need when you need them The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you

More information

N2XY IEC XLPE PVC 0.6/1kV Cable

N2XY IEC XLPE PVC 0.6/1kV Cable N2XY IEC 60502-1 XLPE PVC 0.6/1kV Cable Eland Product Group: A2N APPLICATION These power and control cables are used for electricity supply in low voltage installation systems. They are well adapted to

More information

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES 37- TYPE G-GC 3/C HEAVY-DUTY EASY-STRIP JACKET 000 VOLTS FEATURES Highly durable, abrasion-resistant CPE jacket specially designed

More information

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description.

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description. H05BQ-F, H07BQ-F The harmonized PUR cable with Europe wide registration according to HD 22.10 S1 VDE 0282 Description Application In dry, damp or wet areas for medium duty; e. g. for connection of industrial

More information

MC or MV-105 Copper, TR-XLPE Insulated

MC or MV-105 Copper, TR-XLPE Insulated MC MV-105 Copper, TR-XLPE Insulated 5 kv 35 kv, Shielded Features UL listed as MC MV-105. Cable jacket rated f Sun Resistant and Oil resistant. s 1/0 and larger are UL Listed as CT USE in accdance with

More information

CONNECTING ENERGY AND INFORMATION TO GLOBAL GROWTH

CONNECTING ENERGY AND INFORMATION TO GLOBAL GROWTH CONNECTING ENERGY AND INFORMATION TO GLOBAL GROWTH Welcome to the Prysmian Group, the world s leading cable solutions provider. Over 130 years of aggregated history, 22,000 people in 50 countries and almost

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) Rate per 90m Coil 0.75 7 770 810 920 28 12 1 12 1000 1050 1200 24 12 1.5 16 1470 1540 1760 16 10 2.5 22 2370 2490 2840 12 6 4 29 3490 3670 4190 8 4 6 37 5200 5460 6240 6 3 10 51 9140 9600

More information

P High Voltage Catalogue Cables Australia Powering your Project

P High Voltage Catalogue Cables Australia Powering your Project P +61 8 9367 8978 www.cablesaustralia.com.au High Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD HIGH VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated

More information

UNSHIELDED MULTI CONDUCTOR

UNSHIELDED MULTI CONDUCTOR PLTC 300 VOLT PVC Insulation 105 C, 300 Volts UNSHIELDED MULTI CONDUCTOR For use as instrumentation cable inside or outside in control applications. Suitable for installation in trays, troughs, channels,

More information

POWERMINE Mining cable solutions and ser vices A practical guide

POWERMINE Mining cable solutions and ser vices A practical guide Mining cable solutions and ser vices A practical guide SURFACE MINING Mining cable solutions and services A practical guide Bucket chain excavator Bucket wheel excavator Conveyor belt Dragline Drilling

More information

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed,, PVC Sheathed) 25 47.5 5,292 35 50.5 5,960 50 53.5 6,694 70 58.5 7,816 95

More information

BS6724 SWA/LSZH Cable IEC /1000V

BS6724 SWA/LSZH Cable IEC /1000V BS6724 SWA/LSZH Cable IEC 60502 600/1000V Applications: Power cable suitable for power networks, where fire emission of smoke and toxic fumes creates a serious potential threat. Suitable for direct burial.

More information

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4

More information

Automotive Cables. The Global Cable Solutions Company

Automotive Cables. The Global Cable Solutions Company Automotive Cables The Global Cable Solutions Company Automotive Cables Index Weld Primary Cable WPCS...................................... 4 2000V (UL), 000V c(ul), primary power connections to transformers

More information

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv NA2XSEKY 3 x (25-300) mm² 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, Lead Sheathed, PVC Sheathed) 25 39.5 3,292 35 43.0 3,824 50 46.0 4,419 70 50.5 5,264 95 54.5

More information

Solutions for the mining industry. Special cables for highest demands in the mining sector

Solutions for the mining industry. Special cables for highest demands in the mining sector Solutions for the mining industry Special cables for highest demands in the mining sector Solutions for the mining industry Special cables for highest demands in the mining sector General catalogue Linking

More information

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed ER, FT4, RoHS, Dir Bur; Singles: VW-1; GR I & II; SR; RW90; RoHS; 600 V Features UL Listed as TC-ER - exposed run tray cable. Jacket is rated Sunlight Resistance,

More information

Firetec BS 7846 LPCB BASEC Approved Power Cable

Firetec BS 7846 LPCB BASEC Approved Power Cable Firetec BS 7846 LPCB BASEC Approved Power Cable Eland Product Group: A6F APPLICATION Firetec Power is a fire resistant armoured cable suitable for use in fixed installations for power circuits, fire alarm

More information

Section 8. Portable Cordage & Power Cable

Section 8. Portable Cordage & Power Cable Section 8. 179 Table of Contents Portable and Power Supply Cordage...181 Royal SOOW UL/CSA/MSHA...181 Royal SOOW UL/CSA/MSHA...182 Royal SJOOW UL/CSA/MSHA...183 Seoprene SEOOW UL/CSA/MSHA...184 Seoprene

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 05/2018-19 Dtd : 16th November 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 01/2018-19 Dtd : 21st May 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH BRIGHT

More information

TRATOS OIL&GAS NEK606

TRATOS OIL&GAS NEK606 C A B L E S F O R A M O V I N G W O R L D TRATOS OIL&GAS NEK606 May 2013 Tt 08-13 TRATOS OIL&GAS NEK606 INDEX TRATOS OIL&GAS NEK606 Approvals, quality system and product certification..........................................................................

More information

ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable All Cables Cables PVC Insulated Cables Fire Resistant Cables Aluminium Cables

ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable All Cables Cables PVC Insulated Cables Fire Resistant Cables Aluminium Cables ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable 0.6 / 1kV XLPE Insulated Unarmoured Cables 0.6 / 1kV XLPE Insulated Armoured Cables 1.8 / 3kV XLPE Insulated Armoured Cables 3.6 / 6kV

More information

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation 2 17 BUIS_003.tif 2 18 BUIS_004.tif Selection and dimensioning criteria Refer to Section 4 for further details

More information

CONTROL CABLES CABLES FZE.

CONTROL CABLES CABLES FZE. CONTROL CABLES CABLES FZE www.markcables.com Index Introduction 03 Particulars & Guarantees 05 Copper Conductor, PVC Insulated, PVC Sheathed Cables 08 Copper Conductor, XLPE Insulated, PVC Sheathed Cables

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) 0.75 (Amps) 7 830 880 950 (No. of 28 12 1 12 1070 1130 1230 24 12 1.5 16 1600 1690 1840 16 10 2.5 22 2580 2730 2960 12 6 4 29 3800 4030 4370 8 4 6 37 5640 5980 6490 6 3 10 51 9920 10520 11410

More information

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable Eland Product Group: A9S APPLICATION Multi-core PVC cable with steel wire armour (SWA). Power and auxiliary control cables for use in power

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

20 HUBER+SUHNER RADOX SOLAR

20 HUBER+SUHNER RADOX SOLAR All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX

More information

PRODUCT CATALOGUE Volume 4

PRODUCT CATALOGUE Volume 4 PRODUCT CATALOGUE Volume 4 Tel: +27(11) 864 1606 Main Fax: +27(11) 864 8294 E-mail: yasmin@soew.co.za Admin Fax: +27(11) 908 6439 Website: www.soew.co.za Agent - Durban Congella Cables cc 21 Canada Road

More information

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) 600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power

More information

TELE-FONIKA CABLE AMERICAS

TELE-FONIKA CABLE AMERICAS TELE-FONIKA CABLE AMERICAS TELE-FONIKA CABLE AMERICAS (TF Kable) is a US firm with corporate offices ad mai facility located i Boligbrook, IL ad is a wholly owed subsidiary of TELE-FONIKA Kable SA. TELE-FONIKA,

More information

BS 6724 Armoured Power Cables, 600/1000V

BS 6724 Armoured Power Cables, 600/1000V BS 6724 Armoured Power Cables, 600/1000V Application These cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The

More information

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT (FR) CONFORMING TO IS-694:1990 WITH BRIGHT ANNEALED ELECTROLYTIC BARE COPPER CONDUCTOR FOR VOLTAGE GRADE 1100

More information

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv (Copper, XLPE Insulated, Copper Tape,, PVC Sheathed) 25 38.5 2,603 35 41.5 3,074 50 44.5 3,641 70 48.5 4,536 95 52.0 5,542 120 56.0

More information

Airfield Ground Lighting

Airfield Ground Lighting Airfield Ground Lighting The Draka brand is part of the Prysmian Group, a world leader of the energy and telecom cables and systems industry, with sales of some 7 billion and more than 19,000 employees

More information

March Tratos Mining. Tunnelling cables. Cables for a moving world.

March Tratos Mining. Tunnelling cables. Cables for a moving world. March 2013 Tratos Mining & Tunnelling cables Cables for a moving world www.tratos.eu Introduction Mining & Tunnelling Cables Applications Open-pit mining, underground, drilling, mineshaft Standards AS/NZS,

More information

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY. INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn

More information

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10 NYY-J Cable Application: A VDE approved, solid conductor, black PVC jacketed, 600/1kV power and control cable. These power cables are designed for energy supply cable ducts, power station, industry and

More information

C-L-X Aluminum Sheath Type IEC

C-L-X Aluminum Sheath Type IEC COMPACT STRAND CONSTRUCTION C-L-X Aluminum Sheath A B C D E F G H J Conductor - Compact Stranded Copper Strand Screen - Extruded Semiconducting EPR Insulation - Okoguard EPR Insulation Screen - Extruded

More information

Cable systems We offer you the essential components for a future-oriented e-mobility.

Cable systems We offer you the essential components for a future-oriented e-mobility. Range We are working for you worldwide. Cable systems We offer you the essential components for a future-oriented e-mobility. Individual items We start with your ideas, so you can make your vision of intelligent

More information

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv NA2XSEY 3 x (25-300) mm 2 3.6/6 kv (Aluminium, XLPE Insulated, Copper Tape, PVC Sheathed) 25 36.5 1,380 35 39.5 1,620 50 42.0 1,908 70 46.5 2,322 95 50.0 2,781 120 54.0

More information

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable MachineTuff Cables Tinned Copper Braid Shield (TCB) Excellent Noise Immunity Applications Designed for applications which are installed in occasional flexing and fixed locations. Cable applications include

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

Approvals (Norm references)

Approvals (Norm references) ÖLFLEX ROBUST 200 Robust and weatherproofed Wide range of application opportunities Machine tool manufacture, medical technology, laundries, car washing equipment, chemical industry, composting plants,

More information

Unarmoured Single-Core Cables to BS6883

Unarmoured Single-Core Cables to BS6883 Unarmoured Single-Core Cables to BS TAC. EPR. SW 00/00 V 1 Application Unarmoured cable for use where mechanical protection is not required for fixed wiring in ships and in mobile and fixed offshore units

More information

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES *

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES * october 2004 TRATOSFLEX 2 Selection of type of cable in relation to use Recommended Bending Radius INDEX Current carrying capacities for continuos operation Current carrying capacities for intermittent

More information

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable ed Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable Eland Product Group: A9L APPLICATION Multi-core LSZH cable with

More information

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR TIOI CABLE 0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE 1 2 3 4 5 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE

More information

Okoguard -Okoseal Type IEC

Okoguard -Okoseal Type IEC COMPACT STRAND CONSTRUCTION A B C D E F G H Conductor - Compact Stranded Copper Strand Screen - Extruded Semiconducting EPR Insulation - Okoguard EPR Insulation Screen - Extruded Semiconducting EPR Phase

More information

Expert in mining cables

Expert in mining cables Expert in mining cables High performance in mining cables G Cable Multiconductor with ground cable incorporated, used mainly in mining tasks for cranes feeding, shovels, dredges, drills and other equipments

More information