A NEW BEGINNING IN OIL & GAS. Offshore Cable Range

Size: px
Start display at page:

Download "A NEW BEGINNING IN OIL & GAS. Offshore Cable Range"

Transcription

1 A NEW BEGINNING IN OIL & GAS Offshore Cable Range

2 2

3 TABLE OF CONTENTS TELE-FONIKA Kable S.A. 2 PRODUCTION POTENTIAL 3 CABLE CODE DESIGNATION 6 BS6883/BS7917 (UKOOA) 6571 SW4 0.6/1kV Single Earthing TCu/EPR/ZH UKOOA Type WE (*) SW4 0.6/1kV Single & Multicore Power TCu/EPR/ZH UKOOA Type WF.9 658(*) SW4 0.6/1kV Multicore Power TCu/EPR/ZH/GSWB/ZH UKOOA Type WB (*)(C) SW4 250v Instrumentation TCu/EPR/CAM/ZH/GSWB/ZH UKOOA Type KJ*/KG* (*)(I) SW4 250v Instrumentation TCu/EPR/IAM/ZH/GSWB/ZH UKOOA Type KK*/KH* (*)(I) SW4 0.6/1 kv Instrumentation TCu/EPR/ZH/TPBWB/ZH...19 Fire resistant SW4 0.6/1kV Multicore Power TCu/MGT/EPR/ZH/GSWB/ZH UKOOA TypeYD...21 Fire resistant SW4 250v Instrumentation TCu/MGT/EPR/CAM/ZH/GSWB/ZH UKOOA Type GN/GL...24 Fire resistant SW4 250v Instrumentation TCu/MGT/EPR/IAM/ZH/GSWB/ZH UKOOA Type GP/GM NEK606 UX 0.6/1 KV P15 TCU/EVA...30 RFOU P1/P8 & RFOU EMC 0.6/1 (1.2) kv EPR/EPR/TCWB/EVA BFOU P5/P12 & BFOU EMC 0.6/1 (1.2) KV EPR/EPR/TCWB/EVA RFOU (i) S1/S5 & RFOU (i) EMC 150/250 (300)V EPR/EPR/TCWB/EVA...40 RFOU (c) S2/S6 & RFOU (c) EMC 150/250(300)V EPR/EPR/TCWB/EVA BFOU (i) S3/S7 & BFOU (i) EMC 150/250 (300)V MGT/EPR/EPR/TCWB/EVA BFOU (c) S4/S8 & BFOU (c) EMC 150/250 (300)V MGT/EPR/EPR/TCWB/EVA...46 TECHNICAL SECTION Installation recommendations...49 Minimum bending radius 49 Current ratings (up to 4 core) 49 Current ratings (5 core and above) 50 Correction factors for different ambient temperatures Short circuit rating 50 Conductor resistance values.51 UKOOA cable coding table

4 TELE-FONIKA Kable S.A. The Group TELE-FONIKA Kable (TF Kable) is ranked in the forefront of the global cable industry. The Group is the third manufacturer of cables and wires in Europe with significant development potential, based entirely on Polish capital. TELE-FONIKA Kable Group s considerable investment in research and development centers and multi-skilled work teams, which have included eminent scientists working with our specialists, has been rewarded by the introduction of new-generation products and comprehensive services in the field of cable engineering. Products manufactured in our plants are sold in over 90 countries. Our product assortment includes 25 thousand cable types. The highest quality of our products is confirmed by over 460 certificates for groups of wares licensed by 34 renown centres of certifications worldwide. The company combines the good traditions of the cable industry in Poland and innovative technical solutions. TELE-FONIKA Kable Group consists of six plants four in Poland, one in Ukraine, and one in Serbia. We own over a dozen trade agencies abroad, reaching customers in several dozen countries around the world. TELE-FONIKA Cable Americas Bolingbrook IL TELE-FONIKA Kable Central Europe Hilden TELE-FONIKA Kable Myslenice, Krakow-Wielicka, Krakow-Biezanow, Bydgoszcz TELE-FONIKA Baltic Kaunas Copper Cable Co. Coalville TOW TF KABEL UKRAINE Chernihiv TOW TF KABEL Kiev 2 TELE-FONIKA France Longvic TELE-FONIKA Kabely Zabreh TF KABLE FK Zajecar Zajecar

5 PRODUCTION POTENTIAL Our chief asset is extensive technological know-how in the field of production of wide variety of cables and wires supported by our experienced personnel. Our products match to a great extent the general trends concerning ecology and maintenance safety of wares. Extremely strict legislation in these areas has become the indicator of the technological progress of the manufactured cables. Krakow-Wielicka Plant Krakow-Wielicka Plant was established in In 1992, it received the ISO 9002 certificate (now ISO 9001) and in 1998 the ISO given by the British certification body: BASEC. The plant specializes in the production of rubber insulated cables and wires for mining and industrial applications. All types of rubber mixes used for EPR, CR, EVA and CSP cables are based on an original prescription designed together with research and development centres. The production offer of the plant are also medium voltage cables made in XLPE technology, as well as signal and control wires for special purposes. Krakow-Biezanow Plant Krakow-Biezanow Plant was established in In 2002, it received the ISO 9001 certificate and given by the British certification body: BASEC. The plant specializes in the production of overhead s from alloyed aluminium, s for railway traction network from copper and its alloys and installation wires for general usage. Bydgoszcz Plant Bydgoszcz Plant started production of cables and wires back in In 1992, it received the ISO 9002 certificate (now ISO 9001) and in 1998 the ISO given by the British certification body: BASEC. Bydgoszcz Plant specializes in power supply cables of medium and high voltage up to 500 kv. It is equipped with six modern chain lines for crosslinking polyethylene in XLPE technology. Complementary technological lines for producing the abovementioned cables ranging from thick wire drawing machines, cable stranding machines and screening machines to covering lines and two large-size high voltage laboratories called Faraday cage place the plant in the top of the list of the largest production centres of medium and high voltage cables in Europe. Myslenice Plant Myslenice Plant was established in April 1992 under the name Zakłady Kablowe TELE-FONIKA s.c. In 1995, it received the ISO 9001 certificate and in 1999 the ISO certificate. The certification body is BASEC. In September 2007 the plant received the ISO/TS certificate for automotive cables given by the certification body: SGS. Myślenice Plant specializes in the production of copper and fibre optic telecommunication cables, computer cables and automotive wires. TOW TF Kabel (Ukraine) The plant was established in In 2007, the plant was joined into the TELE-FONIKA Kable Group. This Plant is certified according to ISO 9001 and It specializes in the production of overhead s and cables for voltage up to 1 kv, including halogen-free, fire resistant and flame retardant cables versions. TF Kable Fabrika Kablova Zajecar A.D. (Serbia) The plant was established in In 2007, the plant was joined into the TELE-FONIKA Kable Group. This plant is certified according to ISO 9001 and by DAS Certification Ltd. It specializes in the production of low and medium voltage cables, as well as halogen-free, fire resistant and flame retardant cables, telecommunication cables and PVC and polyethylene-coated s. 3

6 Innovative and safe solutions

7 5

8 CABLE CODE DESIGNATION Materials Fire resistance tape+insulation (Halogen-free) Ethylene propylene rubber - EPR Cross-linked polyethylene XLPE Thermoplastic compound (Halogen-free) Halogen-free thermoset compound EMA or EVA Fibre, tight buffered Fibre in loose tube Bedding/Inner covering or taping (Halogen-free) Screen (poss. with PE or PP) Aluminium (laminated to outer jacket) No armour Copper wire braid (Tinned or bare) Strength member of yarn Galvanized steel wire braid Insulation B R T I U A Q Bedding/inner covering inner sheath F Y Armour/screen L X O A C Outer sheath Thermoplastic compound (Halogen-free) SHF1 I I Halogen-free thermoset compound, SHF2 Halogen-free mud resistant thermoset compound, SHF Mud Additional abbreviation for instrumentation cables: Collective screen (c), Individual pair or triple screen (i) U U EXAMPLE 0.6/1kV BFOU Voltage Fire resisting layer + insulation (HF EPR) Inner covering (HFC) 6 Copper braid Sheath (SHF2 or SHF mud)

9 6571 Earth SW4 0.6/1kV EPR/ZH BS C -40 C UV RoHS Halogen-free, flame retardant, offshore & shipboard earth cables with elastomeric insulation and sheath Standards: BS6883:1999 Design Guidelines, BS EN s, BS Insulating material, BS Sheathing materials, IEC Flame propagation, IEC Flame retardant, IEC Smoke emission properties CONSTRUCTION Tinned annealed circular stranded copper Conductors Class 2 acc. to BS EN Insulation Halogen-free elastomer compound EPR type GP4 acc. to BS Outer sheath Halogen-free, heat-resistant, oil-resisting and flame-retardant elastomer compound type SW4 acc. to BS Colour of outer sheath Green/Yellow CHARACTERISTICS Maximum operating temperature: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Flame retardant: BS EN Category A/F, IEC Smoke emission: BS EN , IEC Corrosive gas emission: BS EN , IEC : type SW4 cables 0.5% acid gas Unarmoured Earth cable for fixed installations in all areas including accommodation and open deck in ships and offshore Application units ELECTRIC CABLE Type SW4 number of cores x size 600/1000V TFK3 BS6883 UKOOA code Cable marking IEC cat. A year metre mark Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request Approval LRS Certificate 08/20071 MINIMUM BENDING RADIUS: Overall diameter of cable (D) Minimum bending radius 10mm 3 D mm 4 D > 25 mm 6 D * D - overall diameter of cable 7

10 Number and cross-sectional area of Class of insulation outer sheath overall diameter of cable net weight of cables SW4 n x mm 2 mm mm mm kg/km UKOOA Code TFK Part Number 1x WE101 G x WE102 G x WE103 G x WE204 G x WE106 G x WE110 G x WE116 G x WE125 G x WE135 G x WE150 G x WE170 G x WE195 G x WE10A G x WE10B G x WE10C G x WE10D G x WE10E G x WE10F G x WE10G G Please refer to technical section for additional information relating to these cables 8

11 657 (*) SW4 0.6/1kV EPR/ZH BS C -40 C UV RoHS Halogen free, flame retardant offshore & shipboard power, control & lighting cables with elastomeric insulation and sheath Standards: BS6883:1999 Design Guidelines, BS EN s, BS Insulating material, BS Sheathing materials, IEC Flame propagation, IEC Flame retardant, IEC Smoke emission properties CONSTRUCTION Tinned annealed circular stranded copper Conductors Class 5 acc. to BS EN Class 2 acc. to BS EN ) For sizes: 1.0 & 1.5 mm 2 2) For sizes 2.5 mm 2 and above Insulation Halogen-free elastomer compound EPR type GP4 acc. to BS Core identification 3) All cores are white with black printed numbers Outer sheath Halogen-free, heat-resistant, oil-resisting and flame-retardant elastomer compound type SW4 acc. to BS Colour of outer sheath Black 1) Class 2 s for sizes below 2.5 mm 2 are available on request 2) Class 5 flexible s for sizes above 2.5 mm 2 are available on request 3) Coloured cores are available on request CHARACTERISTICS Maximum operating temperature: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Flame retardant: BS EN Category A/F, IEC Smoke emission: BS EN , IEC Corrosive gas emission: BS EN , IEC : type SW4 cables 0.5% acid gas Application Power, control or lighting cable for fixed installations in all areas including accommodation and open deck in ships and offshore units Cable marking ELECTRIC CABLE Type SW4 number of cores x size 600/1000V TFK3 BS6883 UKOOA code IEC cat. A year metre mark Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request Approval LRS certificate 08/ MINIMUM BENDING RADIUS: Overall diameter of cable (D) Minimum bending radius 10mm 3 D mm 4 D > 25 mm 6 D * D - overall diameter of cable

12 10 Number and cross-sectional area of Class of insulation outer sheath overall diameter of cable net weight of cables SW4 n x mm 2 mm mm mm kg/km UKOOA Code TFK Part Number 1x WF101 G x WF102 G x WF103 G x WF104 G x WF106 G x WF110 G x WF116 G x WF125 G x WF135 G x WF150 G x WF170 G x WF195 G x WF10A G x WF10B G x WF10C G x WF10D G x WE10E G x WE10F G x WE10G G x WF201 G x WF202 G x WF203 G x WF204 G x WF206 G x WF210 G x WF216 G x WF225 G x WF235 G x WF250 G x WF270 G x WF295 G x WF20A G x WF20B G x WF301 G x WF302 G x WF303 G x WF304 G x WF306 G x WF310 G x WF316 G x WF325 G

13 Number and cross-sectional area of Class of insulation outer sheath overall diameter of cable net weight of cables SW4 n x mm 2 mm mm mm kg/km UKOOA Code TFK Part Number 3x WF335 G x WF350 G x WF370 G x WF395 G x WF30A G x WF30B G x WF30C G x WF30D G x WF401 G x WF402 G x WF403 G x WF404 G x WF406 G x WF410 G x WF416 G x WF425 G x WF435 G x WF450 G x WF470 G x WF495 G x WF40A G x WF40B G x n/a G x n/a G x WF702-7x WF703-12x WFA02-12x WFA03 G x WFB02-19x WFB03 G x WFC02-37x WFD02 - Please refer to technical section for additional information relating to these cables 11

14 658 (*) SW4 0.6/1kV TCu/EPR/ZH/GSWB/ZH BS C -40 C UV RoHS 12 Halogen free, flame retardant, offshore & shipboard power, control & lighting cables with elastomeric insulation and sheath, with steel wire braid Standards: BS6883:1999 Design Guidelines, BS EN s, BS Insulating material, BS Sheathing materials, IEC Flame propagation, IEC Flame retardant, IEC Smoke emission properties CONSTRUCTION Tinned annealed circular stranded copper Conductors Class 5 acc. to BS EN Class 2 acc. to BS EN ) For sizes: 1.0 & 1.5 mm 2 2) For sizes 2.5 mm 2 and above Insulation Halogen-free elastomer compound EPR type GP4 acc. to BS Core identification 3) All cores are white with black printed numbers Inner sheath Halogen free, heat-resistant, oil-resisting and flame-retardant elastomer compound type SW4 acc. to BS Armour/Mechanical Screen 4) Galvanized steel wire braid Separator Separator, suitable tape between the braid and outer sheath Outer sheath Halogen free, heat-resistant, oil-resisting and flame-retardant elastomer compound type SW4 acc. to BS Colour of outer sheath Black 1) Class 2 s for sizes below 2.5 mm 2 are available on request. 2) Class 5 flexible s for sizes above 2.5 mm 2 are available on request 3) Coloured cores are available on request 4) Tinned copper wire braid version is available on request CHARACTERISTICS Maximum operating temperature: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Flame retardant: BS EN Category A/F, IEC Smoke emission: BS EN , IEC Corrosive gas emission: BS EN , IEC : type SW4 cables 0.5% acid gas Application Armoured power, control or lighting cable for fixed installations in all areas including accommodation and open deck in ships and offshore units where halogen free cable protection is required Cable marking ELECTRIC CABLE Type SW4 number of cores x size 600/1000V TFK3 BS6883 UKOOA code IEC cat. A year metre mark Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request Approval LRS certificate 08/20071 MINIMUM BENDING RADIUS: Overall diameter of cable (D) Minimum bending radius < 25 mm 4 D > 25 mm 6 D * D - overall diameter of cable

15 Number and crosssectional area of Class of insulation thickness of inner sheath Diameter of steel wires in braid thickness of outer sheath overall diameter of cable net weight of cables SW4 n x mm 2 mm mm mm mm mm kg/km UKOOA Code TFK Part Number 2x WB201 G x WB202 G x WB203 G x WB204 G x WB206 G x WB210 G x WB216 G x WB225 G x WB235 G x WB250 G x WB270 G x WB295 G x WB20A G x WB20B G x WB20C G x WB20D G x WB20E G x WB301 G x WB302 G x WB303 G x WB304 G x WB306 G x WB310 G x WB316 G x WB325 G x WB335 G x WB350 G x WB370 G x WB395 G x WB30A G x WB30B G x WB30C G x WB30D G x WB30E G x WB401 G x WB402 G x WB403 G x WB404 G x WB406 G x WB410 G

16 Number and crosssectional area of Class of insulation thickness of inner sheath Diameter of steel wires in braid thickness of outer sheath overall diameter of cable net weight of cables SW4 n x mm 2 mm mm mm mm mm kg/km UKOOA Code TFK Part Number 4x WB416 G x WB425 G x WB435 G x WB450 G x WB470 G x WB495 G x WB40A G x WB40B G x WB40C G x WB40D G x WB40E G x n/a G x n/a G x WB702 G x WB703 G x WBA02 G x WBA03 G x WBB02 G x WBB03 G x WBC02 G *27x WBC03 G x WBD02 G * based on standard Please refer to technical section for additional information relating to these cables 14

17 658 (*)(c) SW4 150/250V TCu/EPR/CAM/ZH/GSWB/ZH BS C -40 C UV RoHS Halogen free, flame retardant, offshore & shipboard instrumentation cables, elastomer insulated and sheathed, collectively screened pairs, triples or quads with steel wire braid Standards: BS6883:1999 Design Guidelines, BS EN s, BS Insulating material, BS Sheathing materials, IEC Flame propagation, IEC Flame retardant, IEC Smoke emission properties CONSTRUCTION Conductors Tinned annealed circular stranded copper class 5 1) acc. to BS EN Insulation Halogen-free elastomer compound EPR type GP4 acc. to BS Pairs identification * Black and white with printed number of pairs in a contrasting colour on the insulation Triples identification * Black, white and red with printed number of triples in a contrasting colour on the insulation Separator Polyester tape Collective screen Aluminium/polyester tape with the metallic contact with a tinned copper drain wire Inner sheath Halogen free, heat-resistant, oil-resisting and flame-retardant elastomer compound type SW4, acc. to BS Separator Polyester tape Armour/mechanical screen Galvanized steel wire braid 2) Outer sheath Halogen free, heat-resistant, oil-resisting and flame-retardant elastomer compound type SW4, acc. to BS Colour of outer sheath Grey (Non Intrinsically Safe) or Blue (Intrinsically Safe) 3) 1) Class 2 s are available on request 2) Tinned copper wire braid version is available on request 3) Black outer sheathing is available on request *) Alternative coloured cores are available on request CHARACTERISTICS Maximum operating temperature: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Minimum bending radius: 8 x D; D - overall diameter of cable Flame retardant: BS EN , IEC Category A Smoke emission: BS EN , IEC Corrosive gas emission: BS EN , IEC : type SW4 cables 0.5% acid gas Armoured instrumentation cable for fixed installations in all areas including accommodation and on open deck in ships Application and offshore units where halogen free cable protection is required ELECTRIC CABLE Type SW4 number of pairs or triples, quads x size (C) 150/250V TFK3 BS6883 Cable marking UKOOA code IEC cat. A year metre mark Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request Approval LRS certificate 05/

18 Number of pairs and nominal area of Class of insulation inner sheath Diameter of steel wires in braid outer sheath overall diameter of cable net weight of cables n x 2 x mm 2 mm mm mm mm mm kg/km 2x2x x2x x2x UKOOA Code (Grey/Blue) 3x2x KJH00/KGH00 3x2x KJH01/KGH01 3x2x KJH02/KGH02 5x2x x2x x2x x2x KJJ00/KGJ00 7x2x KJJ01/KGJ01 7x2x KJJ02/KGJ02 10x2x x2x x2x KJK00/KGJ00 12x2x KJK01/KGJ01 12x2x KJK02/KGJ02 20x2x KJL00/KGL00 20x2x KJL01/KGL01 20X2X KJL02/KGL02 16 Number of triples and nominal area of Class of insulation inner sheath Diameter of steel wires in braid outer sheath overall diameter of cable net weight of cables n x 3 x mm 2 mm mm mm mm mm kg/km UKOOA Code (Grey/Blue) 3x3x KJS00/KGS00 3x3x KJS01/KGS01 7x3x KJT00/KGT00 7x3x KJT01/KGT01 12x3x KJU00/KGU00 12x3x KJU01/KGU01 Please refer to technical section for additional information relating to these cables

19 658 (*)(I) SW4 150/250V TCu/EPR/IAM/ZH/GSWB/ZH BS C -40 C UV RoHS Halogen-free, flame retardant, offshore & shipboard instrumentation cables, elastomer insulated and sheathed, individually screened pairs, triples or quads with steel wire braid Standards: BS6883:1999 Design Guidelines, BS EN s, BS Insulating material, BS Sheathing materials, IEC Flame propagation, IEC Flame retardant, IEC Smoke emission properties CONSTRUCTION Tinned annealed circular stranded copper class 5 1) acc. to BS EN Conductors Class 5 1) acc. to BS EN Class 2 acc. to BS EN For 0.75 & 1.5 mm 2 For sizes 2.5 mm 2 Insulation Halogen-free elastomer compound EPR type GP4 acc. to BS Pairs identification * Black and white with printed number of pairs in a contrasting colour on the insulation Triples identification * Black, white and red with printed number of triples in a contrasting colour on the insulation Quads identification * Black, white, red and blue with printed number of quads in a contrasting colour on the insulation Separator Polyester tape Individual screen Aluminium/polyester tape with the metallic contact with a tinned copper drain wire Separator Polyester tape Inner sheath Halogen free, heat-resistant, oil-resisting and flame-retardant elastomer compound type SW4, acc. to BS Armour/mechanical screen Galvanized steel wire braid 2) Outer sheath Halogen free, heat-resistant, oil-resisting and flame-retardant elastomer compound type SW4, acc. to BS Colour of outer sheath Grey (Non Intrinsically Safe) or Blue (Intrinsically Safe) 3) 1) Class 2 s are available on request 2) Tinned copper wire braid version is available on request 3) Black outer sheathing is available on request *) Alternative coloured cores are available on request CHARACTERISTICS Maximum operating temperature: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Minimum bending radius: 8 x D; D - overall diameter of cable Flame retardant: BS EN , IEC Category A Smoke emission: BS EN , IEC Corrosive gas emission: BS EN , IEC : type SW4 cables 0.5% acid gas Armoured instrumentation cable for fixed installations in all areas including accommodation and on open deck in ships Application and offshore units where halogen free cable protection is required ELECTRIC CABLE Type SW4 number of pairs or triples, quads x size (I) 150/250V TFK3 BS6883 Cable marking UKOOA code IEC cat. A year metre mark Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request Approval LRS certificate 05/

20 Number of pairs and nominal area of Class of insulation inner sheath Diameter of steel wires in braid outer sheath overall diameter of cable net weight of cables n x 2 x mm 2 mm mm mm mm mm kg/km UKOOA Code (Grey/Blue) 1x2x KKF00/KHF00 1x2x KKF01/KHF01 1x2x KKF02/KHF02 1x2x KKF03/KHF03 3x2x KKH00/KHH00 3x2x KKH01/KHH01 3x2x KKH02/KHH02 7x2x KKJ00/KHJ00 7x2x KKJ01/KHJ01 7x2x KKJ02/KHJ02 12x2x KKK00/KHK00 12x2x KKK01/KHK01 12x2x KKK02/KHK02 20x2x KKL00/KHL00 20x2x KKL01/KHL01 20x2x KKL02/KHL02 18 Number of triples and nominal area of Class of insulation inner sheath Diameter of steel wires in braid outer sheath overall diameter of cable net weight of cables n x 3 x mm 2 mm mm mm mm mm kg/km UKOOA Code (Grey/Blue) 1x3x KKR00/KHR00 1x3x KKR01/KHR01 1x3x KKR02/KHR02 1x3x KKR03/KHR03 3x3x KKS00/KHS00 3x3x KKS01/KHS01 7x3x KKT00/KHT00 7x3x KKT01/KHT01 12x3x KKU00/KHU00 12x3x KKU01/KHU01 Number of quads and nominal area of Class of insulation inner sheath Diameter of steel wires in braid outer sheath overall diameter of cable net weight of cables n x 4 x mm 2 mm mm mm mm mm kg/km UKOOA Code (Grey/Blue) 1x4x KKX00/KHX00 1x4x KKX01/KHX01 1x4x KKX02/KHX02 1x4x KKX03/KHX03 Please refer to technical section for additional information relating to these cables

21 659(*) SW4 0.6/1 kv TCu/EPR/ZH/TPBWB/ZH BS C -40 C UV RoHS Halogen-free, flame retardant, offshore & shipboard power cables with elastomeric insulation and sheath, with tinned phosphor bronze wire braid Standard: BS6883 CONSTRUCTION Conductors Tinned annealed circular stranded copper class 2 acc. to BS EN ) Insulation Halogen-free elastomer compound EPR type GP4 acc. to BS Core identification Red or black Inner sheath Halogen free, heat-resistant, oil-resisting and flame-retardant elastomer compound type SW4, acc. to BS Screen Tinned phosphor bronze wire braid Separator Separator, suitable tape between the braid and outer sheath Outer sheath Halogen free, heat-resistant, oil-resisting and flame-retardant elastomer compound type SW4, acc. to BS Colour of outer sheath Black 1) Class 5 flexible s are available on request CHARACTERISTICS Maximum operating temperature: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Minimum bending radius: < 25 mm - 4 x D > 25 mm - 6 x D (D - overall diameter of cable) Flame retardant: BS EN Category A/F, IEC Smoke emission: BS EN , IEC Corrosive gas emission: BS EN , IEC : type SW4 cables 0.5% acid gas Armoured power cable for fixed installations in all areas including accommodation and on open deck in ships and Application offshore units where halogen free cable protection is required Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request 19

22 Number and cross-sectional area of Class of the insulation inner sheath Diameter of wires in braid outer sheath overall diameter of cable net weight of cable n x mm 2 mm mm mm mm mm kg/km 1x x x x x x x x x x x x x x x x x x x x

23 TCu/MGT/EPR/ZH/GSWB/ZH 0.6/1kV SW4 BS 7917 MAX +90 C UV RoHS Halogen free, fire resistant, low smoke, low voltage cables with elastomeric insulation and sheath, with steel wire braid Standards: BS EN 60228; BS 7917: Design guidelines, BS Insulating material, BS Sheathing materials, IEC Fire resistant, IEC Flame propagation, IEC Flame retardant, IEC Smoke emission properties CONSTRUCTION TCu Conductors Tinned annealed circular stranded copper according to BS EN class 2 or class 5 MGT/EPR Insulation Mica glass tape Halogen free elastomer compound EPR type GP4 acc. to BS Core identification All cores are white with black printed numbers ZH Inner sheath Halogen free elastomer compound EPR type SB 1 acc. to BS 7917 GSWB Braid armour Galvanized steel wire braid Separator Separator, suitable tape between the braid and outer sheath ZH Outer sheath Halogen free, heat-resistant, oil-resisting and flame-retardant elastomer compound type SW4 acc. to BS Colour of outer sheath Black CHARACTERISTICS Maximum operating temperature: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Flame retardant: BS EN , Category A/F, IEC Fire resitant: IEC Smoke emission: BS EN , IEC Corrosive gas emission: BS EN , IEC : type SW4 cables 0.5% acid gas Elastomer insulated fire resistant (limited circuit integrity) cables for fixed wiring in ships and on mobile and fixed Application offshore units ELECTRIC CABLE TYPE SW4 F1 number of core x size 600/1000V TFK3 BS 7917 UKOOA code Cable marking IEC IEC cat.a year metre mark Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request Approval LRS certificate 14/ MINIMUM BENDING RADIUS: Overall diameter of cable (D) Minimum bending radius < 25 mm 4 D > 25 mm 6 D * D - overall diameter of cable

24 22 Number and crosssectional area of Class of insulation inner sheath Diameter of steel wires in braid outer sheath overall diameter of cable net weight of cables SW4 n x mm 2 mm mm mm mm mm kg/km UKOOA Code 2x YD202 2x YD203 2x YD204 2x YD206 2x YD210 2x YD216 2x YD225 2x YD235 2x YD250 2x YD270 2x YD295 2x YD20A 3x YD302 3x YD303 3x YD304 3x YD306 3x YD310 3x YD316 3x YD325 3x YD335 3x YD350 3x YD370 3x YD395 3x YD30A 4x YD402 4x YD403 4x YD404 4x YD406 4x YD410 4x YD416 4x YD425 4x YD435 4x YD450 4x YD470 4x YD495 4x YD40A 5x N/A 5x N/A 7x YD702 7x YD703

25 Number and crosssectional area of Class of insulation inner sheath Diameter of steel wires in braid outer sheath overall diameter of cable net weight of cables SW4 n x mm 2 mm mm mm mm mm kg/km UKOOA Code 12x YDA02 12x YDA03 19x YDB02 19x YDB03 27x YDC02 27x2.5* YDC03 37x YDD02 * based on standard 23

26 TCu/MGT/EPR/CS/ZH/GSWB/ZH 150/250 V BS 7917 MAX +90 C UV RoHS 24 Halogen free, fire resistant, low smoke, instrumentation cables with elastomeric insulation and sheath, with steel wire braid Standards: BS EN 60228; BS 7917: Design guidelines, BS Insulating material, BS Sheathing materials, IEC Fire resistant, IEC Flame propagation, IEC Flame retardant, IEC Smoke emission properties CONSTRUCTION TCu Conductors Tinned annealed circular stranded copper according to BS EN class 2 or class 5 MGT/EPR Insulation Mica glass tape Halogen free elastomer compound EPR type GP4 acc. to BS Pairs identification Black and white with printed number of pairs in a contrasting color on the insulation CS Screen Collective screen Aluminium/polyester tape with the metallic contact with a tinned copper drain wire ZH Inner sheath Halogen free elastomer compound EPR type SB 1 acc. to BS 7917 GSWB Braid armour Galvanized steel wire braid Separator Separator, suitable tape between the braid and outer sheath ZH Outer sheath Halogen free, heat-resistant, oil-resisting and flame-retardant elastomer compound type SW4 acc. to BS Colour of outer sheath Grey or Blue CHARACTERISTICS Maximum operating temperature: C Maximum temperature during short circuit: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Minimum bending radius: 6 D; D - overall diameter of cable Flame retardant: BS EN , Category A/F, IEC Fire resitant: IEC Smoke emission: BS EN , IEC Gases evolved during combustion: BS EN , IEC : type SW4 cables 0.5% acid gas Elastomer insulated fire resistant (limited circuit integrity) cables for fixed wiring in ships and on mobile and fixed Application offshore units ELECTRIC CABLE TYPE SW4 F1 number of core x size 600/1000V TFK3 BS 7917 UKOOA code Cable marking IEC IEC cat.a year metre mark" Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request Approval LRS certificate 14/20052

27 Number of pairs and nominal area of Class of insulation inner sheath Diameter of steel wires in braid outer sheath overall diameter of cable net weight of cables n x 2 x mm 2 mm mm mm mm mm kg/km UKOOA Code (Grey/Blue) 2x2x0.75* N/A 2x2x1.0* N/A 2x2x1.5* N/A 3x2x GNH00/GLH00 3x2x GNH01/GLH01 3x2x1.5* GNH02/GLH02 3x2x2.5* GNH03/GLH03 7x2x GNJ00/GLJ00 7x2x GNJ01/GLJ01 7x2x1.5* GNJ02/GLJ02 12x2x GNK00/GLK00 12x2x GNK01/GLK01 12x2x1.5* GNK02/GLK02 20x2x GNL00/GLL00 20x2x GNL01/GLL01 20x2x1.5* GNL02/GLL02 * based on standard 25

28 TCu/MGT/EPR/IS/ZH/GSWB/ZH 150/250 V BS 7917 MAX +90 C UV RoHS 26 Halogen free, fire resistant, low smoke, instrumentation cables with elastomeric insulation and sheath, with steel wire braid Standards: BS EN 60228; BS 7917: Design guidelines, BS Insulating material, BS Sheathing materials, IEC Fire resistant, IEC Flame propagation, IEC Flame retardant, IEC Smoke emission properties CONSTRUCTION TCu Conductors Tinned annealed circular stranded copper according to BS EN class 2 or class 5 MGT/EPR Insulation Mica glass tape Halogen free elastomer compound EPR type GP4 acc. to BS Pairs identification Black and white with printed number of pairs in a contrasting colour on the insulation Triples identification Black, white and red with printed number of triples in a contrasting colour on the insulation Quads identification Black, white, red and blue with printed number of quads in a contrasting colour on the insulation IS Screen Individual screen Aluminium/polyester tape with the metallic contact with a tinned copper drain wire ZH Inner sheath Halogen free elastomer compound EPR type SB 1 acc. to BS 7917 GSWB Braid armour Galvanized steel wire braid Separator Separator, suitable tape between the braid and outer sheath ZH Outer sheath Halogen free, heat-resistant, oil-resisting and flame-retardant elastomer compound type SW4 acc. to BS Colour of outer sheath Grey or Blue CHARACTERISTICS Maximum operating temperature: C Maximum temperature during short circuit: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Minimum bending radius: 6 D; D - overall diameter of cable Flame retardant: BS EN , Category A/F, IEC Fire resitant: IEC Smoke emission: BS EN , IEC Gases evolved during combustion: BS EN , IEC : type SW4 cables 0.5% acid gas Elastomer insulated fire resistant (limited circuit integrity) cables for fixed wiring in ships and on mobile and fixed Application offshore units ELECTRIC CABLE Type SW4 F1 number of pairs or triples or quads x size (I) 150/250V TFK3 BS 7917 Cable marking UKOOA code IEC IEC cat.a year metre mark Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request Approval LRS certificate 14/20052

29 Number of pairs and nominal area of Class of insulation inner sheath Diameter of steel wires in braid outer sheath overall diameter of cable net weight of cables n x 2 x mm 2 mm mm mm mm mm kg/km UKOOA Code (Grey/Blue) 1x2x GPF00/GMF00 1x2x GPF01/GMF01 1x2x1.5* GPF02/GMF02 1x2x2.5* GPF03/GMF03 2x2x0.75* N/A 2x2x1.0* N/A 2x2x1.5* N/A 3x2x GPH00/GMH00 3x2x GPH01/GMH01 3x2x1.5* GPH02/GMH02 3x2x2.5* GPH03/GMH03 7x2x GPJ00/GMJ00 7x2x GPJ01/GMJ01 7x2x1.5* GPJ02/GMJ02 12x2x GPK00/GMK00 12x2x GPK01/GMK01 12x2x1.5* GPK02/GMK02 20x2x GPL00/GML00 20x2x GPL01/GML01 20x2x1.5* GPL02/GML02 Number of triples and nominal area of Class of insulation inner sheath Diameter of steel wires in braid outer sheath overall diameter of cable net weight of cables n x 3 x mm 2 mm mm mm mm mm kg/km UKOOA Code (Grey/Blue) 1x3x GPR00/GMR00 1x3x GPR01/GMR01 1x3x1.5* GPR02/GMR02 1x3x2.5* GPR03/GMR03 Number of quads and nominal area of Class of insulation inner sheath Diameter of steel wires in braid outer sheath overall diameter of cable net weight of cables n x 4 x mm 2 mm mm mm mm mm kg/km UKOOA Code (Grey/Blue) 1x4x GPX00/GMX00 1x4x GPX01/GMX01 1x4x1.5* GPX02/GMX02 1x4x2.5* GPX03/GMX03 * based on standard 27

30 We look into the future 28

31 29

32 UX 0.6/1 KV P15 TCU/EVA MAX +90 C UV RoHS Flame retardant, halogen-free Mud resistant insulated Standards: NEK TS 606 Code P5/P12, IEC Design guidelines, IEC 60228, IEC Insulating materials, IEC , IEC Flame retardant, IEC ,2 Halogen free, IEC ,2 Low Smoke CONSTRUCTION Code letter Conductor Tinned annealed stranded circular copper wrapped PETP Insulation U Halogen-free thermoset compound in accordance with type SHF2 Unsheathed X Outer sheath colour Yellow/green CHARACTERISTICS Maximum operating temperature: C Maximum temperature during short circuit: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Flame retardant: IEC (Category A) Smoke emission: IEC Corrosive gas emission: IEC Oil resistance: IEC SHF2, IRM 902 (100 0 C/24h) Mud resistance: NEK 606 (SHF MUD, SHF2) Insulated for earthing and bonding services Application Meets the MUD resistance requirement in NEK TS 606:2009 Other industrial applications Cable marking TF KABLE 3 UX 1000V P15 (SIZE) IEC Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request Approval DNV GL Certificate No: E14148; ABS Certificate No: 15-GD PDA 30 MINIMUM BENDING RADIUS: Overall diameter of cable (D) Minimum bending radius < 25 mm 4 D > 25 mm 6 D * D - overall diameter of cable

33 Size Insulation thickness Diameter over insulation Approx. weight of cable N x mm 2 mm mm kg/km 1x x x x x x x x x x x x x x

34 RFOU P1/P8 & RFOU EMC 0.6/1 (1.2) KV EPR/EPR/TCWB/EVA MAX +90 C UV RoHS 32 Fire retardant halogen-free power cable Mud resistant Standards: NEK TS 606 Code P1/P8, IEC Design guidelines, IEC 60228, IEC Insulating material, IEC Sheathing materials, IEC , IEC Flame retardant, IEC ,2 Halogen free, IEC ,2 Low Smoke CONSTRUCTION Code letter Conductor Tinned annealed stranded circular copper, IEC class 2 Insulation R EP- rubber thermosetting compound, IEC (EPR) Core identification Accordance to HD308 S2 Single core - Black Two core - Blue, Brown Three cores - Brown, Black, Grey, or Green/Yellow, Blue, Brown Four cores - Blue, Brown, Black, Grey or Green/Yellow, Brown, Black, Grey Five cores - Blue, Brown, Black, Grey, Black Multi-cores - White with Black numbers Lay up/shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermosetting compound Armour/screen O Tinned annealed copper wire braid For EMC cable Cu/PET tape under the braid Separator Separator, suitable tape between the braid and outer sheath Outer sheath U Flame retardant, halogen-free, heat-resistant, oil-resisting and mud resistant thermosetting compound type SHF2 acc. to IEC Outer sheath colour Black CHARACTERISTICS Maximum operating temperature: C Maximum temperature during short circuit: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Flame retardant: IEC (Category A) Smoke emission: IEC Corrosive gas emission: IEC Oil resistance: IEC SHF2, IRM 902 (100 0 C/24h) Mud resistance: NEK 606 (SHF MUD, SHF2) Fixed installation for power control and lighting in both EX- and safe areas, general purposes For installation in areas exposed to MUD and drilling/cleaning fluids Application Meets the MUD resistance requirement in NEK TS 606:2009 Marine for fixed wiring installations on Oil and Gas Rigs, Shipboard and other marine applications requiring screened cable for EMC Other industrial applications Cable marking TF KABLE 3 RFOU 0.6/1KV P1/P8 (SIZE) IEC Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request Approval DNV GL Certificate No: E14149; ABS Certificate No: 15-GD PDA

35 Size Insulation thickness Thickness inner covering Diameter of braid wire Thickness outer covering Approx. outer diameter Approx. weight of cable n x mm 2 mm mm mm mm mm kg/km 1x16/ x25/ x35/ x50/ x70/ x95/ x120/ x150/ x185/ x240/ x300/ x1.5/ x2.5/ x4/ x6/ x10/ x16/ x25/ x35/ x50/ x70/ x95/ x120/ x1.5/ G x2.5/ G x4/ G x6/ G x10/ G x16/ G x25/ x35/ x50/ x70/ x95/ x120/ x240/ x1.5/

36 34 Size Insulation thickness Thickness inner covering Diameter of braid wire Thickness outer covering Approx. outer diameter Approx. weight of cable n x mm 2 mm mm mm mm mm kg/km 4G x2.5/ G x4/ G x6/ G x10/ G x16/ G x25/ G x35/ G x50/ G x70/ G x95/ G x120/ G x1.5/ G x2.5/ G x4/ G G G x16/ G G G G x70/ G G x1.5/ x2.5/ x1.5/ x2.5/

37 Size Insulation thickness Thickness inner covering Diameter of braid wire Thickness outer covering Approx. outer diameter Approx. weight of cable n x mm 2 mm mm mm mm mm kg/km 19x1.5/ x2.5/ x1.5/ x2.5/ x1.5/ x2.5/

38 BFOU P5/P12 & BFOU EMC 0.6/1 (1.2) kv EPR/EPR/TCWB/EVA MAX +90 C UV RoHS 36 Fire resistant, flame retardant halogen-free power cable Mud resistant Standards: NEK TS 606 Code P5/P12, IEC Design guidelines, IEC 60228, IEC Insulating material, IEC Sheathing materials, IEC , IEC Flame retardant, IEC Fire resistant, IEC ,2 Halogen free, IEC ,2 Low Smoke CONSTRUCTION Code letter Conductor Tinned annealed stranded circular copper, IEC class 2 Insulation B Mica tape + EP - rubber thermosetting compound, IEC (EPR) Core identification Accordance to HD308 S2 Single core - Black Two core - Blue, Brown Three cores - Brown, Black, Grey, or Green/Yellow, Blue, Brown Four cores - Blue, Brown, Black, Grey or Green/Yellow, Brown, Black, Grey Five cores - Blue, Brown, Black, Grey, Black Multi-cores - White with Black numbers Lay up/shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermosetting compound Armour/screen O Polyester or Cu/PET tape & Tinned annealed copper wire braid For EMC cable Cu/PET tape under the braid Separator Separator, suitable tape between the braid and outer sheath Outer sheath U Flame retardant, halogen-free, heat-resistant, oil-resisting and mud resistant thermosetting compound type SHF2 acc. to IEC Outer sheath colour Black CHARACTERISTICS Maximum operating temperature: C Maximum temperature during short circuit: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Flame retardant: IEC (Category A) Fire resistant: IEC Smoke emission: IEC Corrosive gas emission: IEC Oil resistance: IEC SHF2, IRM 902 (100 0 C/24h) Mud resistance: NEK 606 (SHF MUD, SHF2) Fixed installation for power control and lighting in both EX- and safe areas emergency and critical systems where requirement for fire resistant exists For installation in areas exposed to MUD and drilling/cleaning fluids Application Meets the MUD resistance requirement in NEK TS 606:2009 Marine for fixed wiring installations on Oil and Gas Rigs, Shipboard and other marine applications requiring screened cable for EMC Other industrial applications

39 Cable marking TF KABLE 3 BFOU 0.6/1KV P5/P12 (SIZE) IEC IEC Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request Approval DNV GL Certificate No: E14150; ABS Certificate No: 15-GD PDA MINIMUM BENDING RADIUS: Overall diameter of cable (D) Minimum bending radius < 25 mm 4 D > 25 mm 6 D * D - overall diameter of cable Size Insulation thickness Thickness inner covering Diameter of braid wire Thickness outer covering Approx. outer diameter Approx. weight of cable n x mm 2 mm mm mm mm mm kg/km 1x16/ x25/ x35/ x50/ x70/ x95/ x120/ x150/ x185/ x240/ x300/ x1.5/ x2.5/ x4/ x6/ x10/ x16/ x25/ x35/ x50/ x70/ G x1.5/ G x2.5/ x4/ x6/ x10/ x16/ x25/ G x35/

40 38 Size Insulation thickness Thickness inner covering Diameter of braid wire Thickness outer covering Approx. outer diameter Approx. weight of cable n x mm 2 mm mm mm mm mm kg/km 3x50/ x70/ x95/ x120/ x185/ x1.5/ G x2.5/ G x4/ G x6/ G x10/ G x16/ G x25/ G x35/ G x50/ G x70/ G x95/ G x120/ G G G G x1.5/ G x2.5/ G G G G G G G G

41 Size Insulation thickness Thickness inner covering Diameter of braid wire Thickness outer covering Approx. outer diameter Approx. weight of cable n x mm 2 mm mm mm mm mm kg/km 5G x1.5/ x2.5/ x1.5/ x2.5/ x1.5/ x2.5/ x1.5/ x2.5/ x1.5/ x2.5/

42 RFOU (i) S1/S5 & RFOU (i) EMC 150/250 (300)V EPR/EPR/TCWB/EVA MAX +90 C UV RoHS 40 Flame retardant halogen-free instrumentation cable Mud resistant Standards: NEK TS 606 Code S1/S5, IEC Design guidelines, IEC 60228, IEC Insulating material, IEC Sheathing materials, IEC , IEC Flame retardant, IEC ,2 Halogen free, IEC ,2 Low Smoke CONSTRUCTION Code letter Conductors Tinned annealed stranded circular copper, IEC class 2 Insulation R EP- rubber thermosetting compound, IEC (EPR) Pair, Triple, Quad twisting Colour coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples are identified by numbers printed directly on the insulated s Lay up/shielding Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with polyester tape Inner covering F Flame retardant and halogen-free thermosetting compound Armour/screen O Polyester or Cu/PET tape & Tinned annealed copper wire braid For EMC cable Cu/PET tape under the braid Separator Separator, suitable tape between the braid and outer sheath Outer sheath U Flame retardant, halogen-free and mud resistant thermosetting compound type SHF2 acc. to IEC Outer sheath colour Grey or blue CHARACTERISTICS Maximum operating temperature: C Maximum temperature during short circuit: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Minimum bending radius: 6 D Flame retardant: IEC (Category A) Smoke emission: IEC Corrosive gas emission: IEC Oil resistance: IEC SHF2, IRM 902 (100 0 C/24h) Mud resistance: NEK 606 (SHF MUD, SHF2) Fixed installation for instrumentation, communication, control and alarm system in both EX - and safe areas Meets the MUD resistance requirement in NEK TS 606 Application Marine for fixed wiring installations on Oil and Gas Rigs, Shipboard and other marine applications requiring screened cable for EMC Other industrial applications Cable marking TF KABLE 3 RFOU (i) 250V S1/S5 2 PAIR 0.75mm 2 IEC IEC Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request Approval DNV GL Certificate No: E14151; ABS Certificate No: 15-GD PDA

43 Size Class of Insulation thickness Thickness of inner sheath Diameter of braid wire Thickness of outer sheath overall diameter net weight of cable N x 2 x mm 2 mm mm mm mm mm kg/km 1x2x x2x x2x x2x x2x x2x x2x x2x x3x x3x x3x x3x x3x x3x x3x x3x x2x x2x x2x x2x x2x x2x x2x x2x x3x x3x x3x x3x x3x x3x x3x x2x x2x x2x

44 RFOU (c) S2/S6 & RFOU (c) EMC 150/250(300)V EPR/EPR/TCWB/EVA MAX +90 C UV RoHS 42 Flame retardant halogen-free instrumentation cable Mud resistant Standards: NEK TS 606 Code S2/S6, IEC Design guidelines, IEC 60228, IEC Insulating material, IEC Sheathing materials, IEC , IEC Flame retardant, IEC ,2 Halogen free, IEC ,2 Low Smoke CONSTRUCTION Code letter Conductors Tinned annealed stranded circular copper, IEC class 2 Insulation R EP- rubber thermosetting compound, IEC (EPR) Pair, Triple, Quad twisting Colour coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectivelly and screened by copper backed polyester tape with tinned copper drain wire. Pairs/triples are identified by numbers printed directly on the insulated s Inner covering F Flame retardant and halogen-free thermosetting compound Armour/screen O Polyester or Cu/PET tape & Tinned annealed copper wire braid For EMC cable Cu/PET tape under the braid Separator Separator, suitable tape between the braid and outer sheath Outer sheath U Flame retardant, halogen-free and mud resistant thermosetting compound type SHF2 acc. to IEC Outer sheath colour Grey or blue CHARACTERISTICS Maximum operating temperature: C Maximum temperature during short circuit: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Minimum bending radius: 6 D Flame retardant: IEC (Category A) Smoke emission: IEC Corrosive gas emission: IEC Oil resistance: IEC SHF2, IRM 902 (100 0 C/24h) Mud resistance: NEK 606 (SHF MUD, SHF2) Fixed installation for instrumentation, communication, control and alarm system in both EX - and safe areas Meets the MUD resistance requirement in NEK TS 606 Application Marine for fixed wiring installations on Oil and Gas Rigs, Shipboard and other marine applications requiring screened cable for EMC Other industrial applications Cable marking TF KABLE 3 RFOU (c) 250V S2/S6 2 PAIR 0.75mm 2 IEC IEC Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request Approval DNV GL Certificate No: E14151; ABS Certificate No: 15-GD PDA

45 Size Class of Insulation thickness Thickness of inner sheath Diameter of braid wire Thickness of outer sheath overall diameter net weight of cable N x 2 x mm 2 mm mm mm mm mm kg/km 2x2x x2x x2x x2x x2x x2x x2x x3x x3x x3x x3x x3x x3x x2x x2x x2x x2x x2x x2x x2x x2x x3x x3x x3x x3x x3x x3x x2x x2x x2x x2x

46 BFOU (i) S3/S7 & BFOU (i) EMC 150/250 (300)V MGT/EPR/EPR/TCWB/EVA MAX +90 C UV RoHS 44 Fire resistant, flame retardant halogen-free instrumentation cable Mud resistant Standards: NEK TS 606 Code S3/S7, IEC Design guidelines, IEC 60228, IEC Insulating material, IEC Sheathing materials, IEC , IEC Flame retardant, IEC Fire resistant, IEC ,2 Halogen free, IEC ,2 Low Smoke CONSTRUCTION Code letter Conductors Tinned annealed stranded circular copper, IEC class 2 Insulation B Mica tape EP - rubber thermosetting compound, IEC (EPR) Pair, Triple, Quad twisting Color coded cores twisted together. Pairs/Triples are screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/ triples are identified by numbers printed directly on the insulated s Lay up/shielding Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped with polyester tape Inner covering F Flame retardant and halogen-free thermosetting compound Armour/screen O Polyester or Cu/PET tape & Tinned annealed copper wire braid For EMC cable Cu/PET tape under the braid Separator Separator, suitable tape between the braid and outer sheath Outer sheath U Flame retardant, halogen free and mud resistant thermosetting compound SHF2 (IEC ) Outer sheath colour Grey or blue CHARACTERISTICS Maximum operating temperature: C Maximum temperature during short circuit: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Minimum bending radius: 6 D Flame retardant: IEC (Category A) Fire resistant: IEC Smoke emission: IEC Corrosive gas emission: IEC Oil resistance: IEC SHF2, IRM 902 (100 0 C/24h) Mud resistance: NEK 606 (SHF MUD, SHF2) Fixed installation for instrumentation, communication, control and alarm system in both EX and safe areas emergency and critical systems where requirements for fire resistance exists Application Meets the MUD resistance requirement in NEK TS 606 Marine For fixed wiring installations on Oil and Gas Rigs, Shipboard and other marine applications requiring screened cable for EMC Other industrial applications Cable marking TF KABLE 3 BFOU (i) 250V S3/S7 2 PAIR 0.75mm 2 IEC IEC IEC Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request Approval DNV GL Certificate No: E14152; ABS Certificate No: 15-GD PDA

47 Size Class of Insulation thickness Thickness of inner sheath Diameter of braid wire Thickness of outer sheath overall diameter net weight of cable N x 2 x mm 2 mm mm mm mm mm kg/km 1x2x x2x x2x x2x x2x x2x x2x x2x x3x x3x x3x x3x x3x x3x x3x x3x x2x x2x x2x x2x x2x x2x x2x x2x x3x x3x x3x x3x x3x x3x x3x x2x x2x x2x x2x x2x x3x x3x

48 BFOU (c) S4/S8 & BFOU (c) EMC 150/250 (300)V MGT/EPR/EPR/TCWB/EVA MAX +90 C UV RoHS 46 Fire resistant, flame retardant halogen-free instrumentation cable Mud resistant Standards: NEK TS 606 Code S4/S8, IEC Design guidelines, IEC 60228, IEC Insulating material, IEC Sheathing materials, IEC , IEC Flame retardant, IEC Fire resistant, IEC ,2 Halogen free, IEC ,2 Low Smoke CONSTRUCTION Code letter Conductor Tinned annealed stranded circular copper, IEC class 2 Insulation B Mica tape + EP - rubber thermosetting compound, IEC (EPR) Pair, Triple, Quad twisting Color coded cores twisted together and wrapped with polyester tape. Pairs/ Triples are laid up collectively and screened by copper backed polyester tape with tinned copper drain wire. Pairs/ triples are identified by numbers printed directly on the insulated s Lay up/shielding Cores laid up in concentric layers Inner covering F Flame retardant and halogen-free thermosetting compound Armour/screen O Polyester or Cu/PET tape & Tinned annealed copper wire braid For EMC cable Cu/PET tape under the braid Separator Separator, suitable tape between the braid and outer sheath Outer sheath U Flame retardant, halogen free and mud resistant thermosetting compound SHF2 (IEC ) Outer sheath colour Grey or blue CHARACTERISTICS Maximum operating temperature: C Maximum temperature during short circuit: C Lowest ambient temperature for fixed installation: C Lowest installation temperature: C Minimum bending radius: 6 D Flame retardant: IEC (Category A) Fire resistant: IEC Smoke emission: IEC Corrosive gas emission: IEC Oil resistance: IEC SHF2, IRM 902 (100 0 C/24h) Mud resistance: NEK 606 (SHF MUD, SHF2) Fixed installation for instrumentation, communication, control and alarm system in both EX and safe areas emergency and critical systems where requirements for fire resistance exists Application Meets the MUD resistance requirement in NEK TS 606 Marine For fixed wiring installations on Oil and Gas Rigs, Shipboard and other marine applications requiring screened cable for EMC Other industrial applications Cable marking TF KABLE 3 BFOU (c) 250V S4/S8 2 PAIR 0.75mm 2 IEC IEC IEC Standard length cable packing 1000m on drums. Other forms of packing and delivery are available on request Approval DNV GL Certificate No: E14152; ABS Certificate No: 15-GD PDA

49 Size Class of Insulation thickness Thickness of inner sheath Diameter of braid wire Thickness of outer sheath overall diameter net weight of cable N x 2 x mm 2 mm mm mm mm mm kg/km 2x2x x2x x2x x2x x2x x2x x2x x3x x3x x3x x3x x3x x3x x2x x2x x2x x2x x2x x2x x3x x3x x3x x3x x3x x3x x2x x2x x2x x2x x3x x3x x3x

50 48 TECHNICAL SECTION To be read in conjunction with the relevant cable datasheet

51 Installation recommendations (in accordance with BS 6883:1999 appendix B) Installation Temperature Minimum recommended installation temperature for cables according to BS6883 is C Minimum bending radius (MBR) The cables specified in BS6883 should not be bent to an internal radius smaller than that given in the table A1 below. Wherever possible larger installation radii should be used. Type of cable Overall diameter Minimum bending radius Screened multi-pair, triple or quad Any 8 D Multi-core unarmoured (unbraided) 600/1000v Multi-core armoured (braided) 600/1000v D - is the overall diameter of the cable 10mm >10mm to 25mm >25mm 25mm >25mm Current Ratings (in accordance with IEC based on ambient air temperature of 45 0 C) 3 D 4 D 6 D 4 D 6 D cross-sectional area mm 2 Single core Ampere Insulation class temperature 90 0 C 2 core Ampere 3 & 4 core Ampere

52 Current ratings for 5 cores and over Number of cores cross-sectional area 1mm 2 Ampere Insulation class temperature 90 0 C 1.5mm 2 Ampere mm 2 Ampere The ambient temperature of 45 0 C, on which the above current ratings are based, is considered as a standard value for the ambient air temperature, generally applicable for any kind of ship or offshore platform in any climate. Correction factors for different ambient air temperatures Maximum temperature Ambient temperature, 0 C Correction factor Where more than six bunched cables on cable trays, in cable conduits. Pipes or trunking are expected to operate simultaneously full rated capacity, a correction factor of 0.85 should be applied. Short circuit rating Short circuit rating calculation based on formula: 90 0 C S=Cross-section of, mm 2 t=duration of the short circuit, s T k =Maximum rated temperature, short circuit, 0 C T b =Maximum rated temperature, normal, 0 C 50 Size Maximum short circuit current rating for 1 second Maximum short circuit current rating for 3 seconds Maximum short circuit current rating for 5 seconds mm 2 ka ka ka

53 Size Maximum short circuit current rating for 1 second Maximum short circuit current rating for 3 seconds Maximum short circuit current rating for 5 seconds mm 2 ka ka ka Conductor resistance for Power cables (in accordance with IEC60228) Conductor class 2 Conductor class 5 Cross-section of Tinned copper Tinned copper Maximum resistance at 20 0 C Maximum resistance at 90 0 C Maximum resistance at 20 0 C Maximum resistance at 90 0 C mm 2 Ω/km Ω/km Ω/km Ω/km Conductor resistance for Instrumentation cables (in accordance with IEC60228) Conductor class 5 Cross-section of Tinned copper Maximum resistance at 20 0 C Maximum resistance at 90 0 C mm 2 Ω/km Ω/km

54 UKOOA CABLE CODING 52 1 st Character Type Voltage Type Voltage F Fire resistant, reduced halogen 150/250V M Flame retardant, reduced halogen 3.8/6.6KV G Fire resistant, low smoke & fume 150/250V N Flame retardant, reduced halogen 1.9/3.3KV H Flame retardant, reduced halogen 8.7/15KV P Flame retardant, reduced halogen 6.35/11KV J Flame retardant, reduced halogen 150/250V W Flame retardant, low smoke & fume 600/1000V K Flame retardant, low smoke & fume 150/250V X Fire resistant, reduced halogen 600/1000V L Flame retardant, reduced halogen 600/1000V Y Fire resistant, low smoke & fume 600/1000V 2 nd Character Basic Construction Sheath Colour Armour Screen A Flame retardant Black (600/1000V), Red (HV) Bronze braid (TPBWB) - B Flame retardant Black (600/1000V), Red (HV) GSWB - C Fire resistant Black (600/1000V) Bronze braid (TPBWB) - D Fire resistant Black (600/1000V) GSWB - E Flame retardant Green/Yellow None - F Flame retardant Black None - G Flame retardant Light Blue GSWB Collective H Flame retardant Light Blue GSWB Individual J Flame retardant Grey GSWB Collective K Flame retardant Grey GSWB Individual L Fire resistant Light Blue GSWB Collective M Fire resistant Light Blue GSWB Individual N Fire resistant Grey GSWB Collective P Fire resistant Grey GSWB Individual Y Flame retardant Orange GSWB Co-axial 3 rd Character 1 Single core B 19 core K 12 pair T 7 triple 2 2 core C 27 core L 20 pair U 12 triple 3 3 core D 37 core M 27 pair X 1 quad 4 4 core F 1 pair N 37 pair Y 3 quad 7 7 core H 3 pair R 1 triple Z 7 quad A 12 core J 7 pair S 3 triple 4 th & 5 th Character Conductor Size Type of stranding Conductor Size Type of stranding mm 2 Flexible tinned copper (Class5) mm 2 Tinned copper (Class2) mm 2 Flexible tinned copper (Class5) mm 2 Tinned copper (Class2) mm 2 Flexible tinned copper (Class5) 0A 120 mm 2 Tinned copper (Class2) mm 2 Tinned copper (Class2) 0B 150 mm 2 Tinned copper (Class2) 04 4 mm 2 Tinned copper (Class2) 0C 185 mm 2 Tinned copper (Class2) 06 6 mm 2 Tinned copper (Class2) 0D 240 mm 2 Tinned copper (Class2) mm 2 Tinned copper (Class2) 0E 300 mm 2 Tinned copper (Class2) mm 2 Tinned copper (Class2) 0F 400 mm 2 Tinned copper (Class2) mm 2 Tinned copper (Class2) 0G 500 mm 2 Tinned copper (Class2) mm 2 Tinned copper (Class2) 0H 630 mm 2 Tinned copper (Class2) mm 2 Tinned copper (Class2)

55 NOTES 53 All the information contained in this document - including tables, graphics and diagrams - is given in good faith and believed to be correct at the time of publication. The information does not constitute a warranty nor representation for which TELE-FONIKA Kable assumes legal responsibility. TELE-FONIKA Kable reserves rights to introduce changes to the document at any time. All Rights Reserved TELE-FONIKA Kable S.A. Edition III

56 TELE-FONIKA Kable S.A. Wielicka 114, Krakow, Poland T: (+48)

POWER YOUR MINE WITH TF Kable MINING CABLES AUSTRALIA

POWER YOUR MINE WITH TF Kable MINING CABLES AUSTRALIA POWER YOUR MINE WITH TF Kable MINING CABLES AUSTRALIA Table of Contents rubber CABLES 2 TELE-FONIKA Kable 3 PRODUCTION POTENTIAL 5 1 PRODUCTION MATRIX 6 GENERAL UNDERGROUND COAL MINING CABLES TYPE 209

More information

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire. We are a major supplier of housewiring, low voltage, power and fire resistant cables for

More information

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E Page 1 of 5 extended Fire Resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU-XFR(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable Page 1 of 5 5 4 1 2 3 Fire resistant, flame retardant halogen-free instrumentation cable. Mud resistant BFOU(i) 150/250(300)V MGT/EPR/EPR/TCWB/EVA NEK TS 606 CodeS3/S7 Operating temperature : 90 C Operating

More information

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable Page 1 5 1 1 1 2 3 Flame retardant halogen-free instrumentation cable. Mud resistant RFOU(i) 150/250(300)V EPR/EPR/TCWB/EVA NEK TS 606 CodeS1/S5 Operating temperature : 90 C Operating Voltage : 150/250(300)V

More information

Medium voltage cables

Medium voltage cables Medium voltage cables Leading producer of cables and cable systems 2 The TELE-FONIKA Kable Group has been present on the domestic and international cable industry market for more than 25 years. A stable

More information

Technical Information

Technical Information Cable Code Designation A cable code of 2 letters (1. and 4.) or 4 letters is used to describe the construction. For example: 1st Letter: Insulation: B: Fire resistant tape + insulation (Halogen-free) R:

More information

TRATOS OIL&GAS NEK606

TRATOS OIL&GAS NEK606 C A B L E S F O R A M O V I N G W O R L D TRATOS OIL&GAS NEK606 May 2013 Tt 08-13 TRATOS OIL&GAS NEK606 INDEX TRATOS OIL&GAS NEK606 Approvals, quality system and product certification..........................................................................

More information

BFOU 0.6/1kV Power Cable

BFOU 0.6/1kV Power Cable BFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame resistant, fire retardant, halogen free cable for fixed installation in various electromechanical and electric equipment, emergency

More information

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant)

Caledonian. Caledonian Offshore & Marine Cables. BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian Caledonian Offshore & Marine Cables BS 6883 STANDARD (Flame Retardant) BS 7917 STANDARD (Fire Resisitant) Caledonian, established in 1978, offers one of the most complete lines of fiber and

More information

TRATOS OIL&GAS BS BS7917

TRATOS OIL&GAS BS BS7917 CABLES FOR A MOVING WORLD TRATOS OIL&GAS BS6883 - BS7917 Feb 2015 Tt 06-15 TRATOS OIL&GAS BS6883 - BS7917 TRATOS OIL&GAS Tratos have been involved in the Oil & Gas industry for over 40 years, manufacturing

More information

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) Caledonian Flame Retardant Instrumentation Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair) RE-2X(st)YSWAY

More information

RFOU 0.6/1kV Power Cable

RFOU 0.6/1kV Power Cable RFOU 0.6/1kV Power Cable Eland Product Group: ASH APPLICATION A flame retardant halogen free power, control and lighting cable for fixed installation. Suitable for use in all conditions in a marine environment

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATION Power and control cable for fixed installations. Designed to fulfill requirements

More information

flame Retardant overall screened Instrumentation cables (Multicore)

flame Retardant overall screened Instrumentation cables (Multicore) Caledonian flame Retardant Instrumentation cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant overall screened Instrumentation cables (Multicore) Re-2X(st)y Re-2X(st)ysWay PVC Outer

More information

FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.

FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. OFFSHORE CABLES FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR. General Cable Corporation is one of the world s leading cable manufacturing companies. In its work it has contributed decisively

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended

More information

Unarmoured Single-Core Cables to BS6883

Unarmoured Single-Core Cables to BS6883 Unarmoured Single-Core Cables to BS TAC. EPR. SW 00/00 V 1 Application Unarmoured cable for use where mechanical protection is not required for fixed wiring in ships and in mobile and fixed offshore units

More information

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black -I Insulated, non-sheathed Insulated and sheathed Insulated, ed and sheathed 1. : Plain stranded annealed Class 2 Copper. 1.5mm 2 up to 630mm 2 Plain stranded annealed Class 2 Copper. Plain stranded annealed

More information

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR TIOI CABLE 0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE 1 2 3 4 5 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE

More information

BS 6724 Armoured Power Cables, 600/1000V

BS 6724 Armoured Power Cables, 600/1000V BS 6724 Armoured Power Cables, 600/1000V Application These cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour. The

More information

Power & Control Cables

Power & Control Cables The Quality Connection Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 The Quality Connection www.leoni-industrial-projects.com The LEONI Group Cable expertise for the most various industrial markets.

More information

Power & Control Cable IEC

Power & Control Cable IEC (2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).

More information

FR-3S Fire Resistant Cables

FR-3S Fire Resistant Cables FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and

More information

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores) FTX400 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2) FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/SWA/LSZH

More information

Standardization IEC /-351/-353. Conductor material

Standardization IEC /-351/-353. Conductor material Low voltage power cables Fire resistant low voltage power cables according to the new demanding IEC -60331 1/2 specifications for power and lighting applications in all ship areas, with reduced diameter

More information

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue) XLPE INSULATED AND PVC OR LOW SMOKE HALOGEN FREE (LSHF) SHEATHED CABLES Voltage Rating (Uo/U) : 00/00V, 1/0V or 00/3V Standards Complied Main Specification Materials Test Methods Flame Retardant Test Test

More information

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 1930 TKF developed from

More information

BS6724 SWA/LSZH Cable IEC /1000V

BS6724 SWA/LSZH Cable IEC /1000V BS6724 SWA/LSZH Cable IEC 60502 600/1000V Applications: Power cable suitable for power networks, where fire emission of smoke and toxic fumes creates a serious potential threat. Suitable for direct burial.

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY den-belitsky / Fotolia CONTENT OVERVIEW Who we are.........................................................................................................

More information

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey) LOW SMOKE HALOGEN FREE (LSHF) FIRE RESISTANT CABLES Voltage Rating (Uo/U) : /0V, /7V or 00/00V Standards Complied Main Specification Fire Tests Flame Retardant Test Test on Acid Gas Evolved Smoke Density

More information

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V PRODUCT INFORMATION Screened halogen-free control cable with improved fire characteristics -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V Info CPR:

More information

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC Power & Control Cables U o /U 0.6/1 kv - IEC 60502-1 2 KERPEN GmbH & Co. KG 07.2005 Printing errors excepted. Subject to alteration List of Contents Introduction Page B1 Construction Page B3 Use Page B4

More information

Connecting globally. TFCrane

Connecting globally. TFCrane Connecting globally 1 Table of Contents TELE-FONIK Kable S.. 4 PPLICTION 6 dditional PramETErs 7 REELING CBLE - 0,6/1kV NSHTÖU -J/O 8 (N)SHTÖU -J + FO 15 2 3 REELING CBLE - 3,6/6kV, 6/10kV, 8,7/15kV, 12/20kV

More information

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free) SABIX Ultra Standards: EN 60332-1-2 EN 60332-3 Cat C or D IEC 60754-1 (halogen-free) IEC 60754-2 + EN 50267-2-2 (corrosivity of gases) EN 61034 (smoke density) NF C 32-70 C1 (fire performance acc. to French

More information

FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE

FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE Marine Cables FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for over 165 years, always dedicated to connecting

More information

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable RE-T2X(st)H SWAH - BS EN 50288-7 Mica XLPE / LSZH / CAM / SWA / LSZH Cable Eland Product Group: I APPLICATION These cables are designed to connect electrical instrument circuits and provide counication

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING. SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING www.sab-kabel.de CONTENT OVERVIEW Who we are.........................................................................................................

More information

Any inquiries, please feel free to contact or Caledonian

Any inquiries, please feel free to contact or Caledonian Caledonian Low Voltage cables to IEC 60502 Standard www.caledonian-cables.co.uk www.caledonian-cables.net 1 Addison Company Profile Caledonian. established in 1978.offers one of the most complete lines

More information

ÖLFLEX CLASSIC 110 H Info Benefits

ÖLFLEX CLASSIC 110 H Info Benefits Halogen-free control cable, oil resistant and very flexible - halogen-free control cable, HFFR, oil-resistant, very flexible and cold-resistant down to -30 C for various applications, CPR Info CPR: Article

More information

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3. TI CABLE 0.6/1KV FLAME RETARDANT UNARMORED CABLE 1 2 3 ICC CABLE CORP. PRODUCT DESCRIPTION 0.6/1KV ONE - FIVE CONDUCTOR, MULTI-CONDUCTOR COMMERCIAL MARINE POWER & CONTROL CABLE 90 C TEMPERATURE RATING

More information

Cables for Railway Technology

Cables for Railway Technology Cables for Railway Technology www.sab-worldwide.com Content q In case that you don t find a suitable cable for your special application, we are always prepared to design a cable according to your individual

More information

THERMOCOUPLE CABLES THERMOELECTRICITY

THERMOCOUPLE CABLES THERMOELECTRICITY THERMOCOUPLE CABLES THERMOELECTRICITY When a metallic conductor is exposed to a difference of temperature between the two extremities, an electromotive force (emf) is generated by the temperature gradient,

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

Firetec BS 7846 LPCB BASEC Approved Power Cable

Firetec BS 7846 LPCB BASEC Approved Power Cable Firetec BS 7846 LPCB BASEC Approved Power Cable Eland Product Group: A6F APPLICATION Firetec Power is a fire resistant armoured cable suitable for use in fixed installations for power circuits, fire alarm

More information

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) www.caledonian-s.co.uk www.addison-s.com 600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) FGD400 1RVMV-R (CU/XLPE/PVC/SWA/PVC 600/1000V

More information

The cables you need when you need them

The cables you need when you need them The cables you need when you need them Whether you need standard or specialist cables you re looking in the right place. With a massive range available on short lead-times we can deliver the product you

More information

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB INDUSTRIAL JELLY FLOODED COAXIAL CABLES Polycab Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded PVC Black Jacketed Industrial

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 05/2018-19 Dtd : 16th November 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH

More information

Caledonian Fire Resistant Optic Fiber Cables

Caledonian Fire Resistant Optic Fiber Cables Fire Resistant Optic Cables Fire resistant Central Loose Optic cables Application These cables are characterized by light weight and small diameter, suitable for both aerial and duct installation. They

More information

BlueLine Cables for Shipbuilding

BlueLine Cables for Shipbuilding BlueLine Cables for Shipbuilding www.sab-worldwide.com Content page The Company..........................................................................................................................

More information

CONNECTING ENERGY AND INFORMATION TO GLOBAL GROWTH

CONNECTING ENERGY AND INFORMATION TO GLOBAL GROWTH CONNECTING ENERGY AND INFORMATION TO GLOBAL GROWTH Welcome to the Prysmian Group, the world s leading cable solutions provider. Over 130 years of aggregated history, 22,000 people in 50 countries and almost

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Industrial Cables LP No. 01/2018-19 Dtd : 21st May 2018 POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT LEAD FREE (FRLF) CONFORMING TO IS-694:1990 WITH BRIGHT

More information

LSZH Fire Resistant Cables

LSZH Fire Resistant Cables 300/500V Single-Core ~ 4-Core Mica Tape Fire Barrier, XLPE Insulated, LSZH Sheathed, Fire Resistant Cable CU/MICA/XLPE/LSZH of the electrical circuit is critical in maintaining power supply. Applications

More information

MARINE AND OFFSHORE CABLES

MARINE AND OFFSHORE CABLES MARINE AND OFFSHORE CABLES FOREWORD General Cable is a World leader in cable manufacturing with 38 modern production facilities in North America, Europe and Oceania, employing more than 10,000 people throughout

More information

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax Introduction General Cable is a world leader in cable manufacture and one of the world s largest suppliers to the Offshore and sector. General Cable s extensive experience in the offshore market translates

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) 0.75 (Amps) 7 830 880 950 (No. of 28 12 1 12 1070 1130 1230 24 12 1.5 16 1600 1690 1840 16 10 2.5 22 2580 2730 2960 12 6 4 29 3800 4030 4370 8 4 6 37 5640 5980 6490 6 3 10 51 9920 10520 11410

More information

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings HEPR insulated flexible with braided shield of red copper wires and plastic sheath of halogen-free flame retardant and without emission of corrosive gases. The keeps the electrical characteristics for

More information

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332 600/1000V XLPE Insulated PVC Sheathed Armoured Power Cables -5 Cores CU/XLPE/PVC 600/1000V Class CU/XLPE/PVC/SWA/PVC 600/1000V Class Application: The cables are mainly used in power stations, mass transit

More information

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

LDC Pricelist. ( WEF 1st August 2017 ) POLYCAB 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured. INDUSTRIAL JELLY FLOODED COAXIAL CABLES LDC Pricelist LAN (COMPUTER) CABLES "POLYCAB" Gas Injected Physical Polyethylene Foam Insulation with Laminated Aluminium Tape and Aluminium Wire Braid, Jelly Flooded

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. POLYCAB PVC INSULATED SINGLE CORE UNSHEATHED INDUSTRIAL (MULTISTRAND) CABLES - FLAME RETARDANT (FR) CONFORMING TO IS-694:1990 WITH BRIGHT ANNEALED ELECTROLYTIC BARE COPPER CONDUCTOR FOR VOLTAGE GRADE 1100

More information

SECTORFLEX CABLE CATALOGUE

SECTORFLEX CABLE CATALOGUE SECTORFLEX CABLE CATALOGUE SAVING SPACE AND TIME R & D + i SERVING OUR CUSTOMERS PRESENTATION One of the largest companies in the sector worldwide. General Cable is a leading company in the manufacture

More information

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V Halogen-free control cable with improved fire characteristics - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V Info CPR: choice under www.lappkabel.com/cpr For

More information

CRANE, CONVEYOR, LIFT & REELING CABLES

CRANE, CONVEYOR, LIFT & REELING CABLES CRANE, CONVEYOR, LIFT & REELING CABLES F-PVC Series... 158 F-TPECY Series...160 P Series...161 PR Series...162 PRRT Series... 164 PRVS Series...166 Reeling/Trailing Cable Enquiry Form...168 P: (09) 264

More information

14 HH EAC/CTP CE RoHS-II conform

14 HH EAC/CTP CE RoHS-II conform Outer jacket: Pressure extruded PUR mixture Inner jacket: Pressure extruded, gusset filling PUR mixture 12 cores or more: Bundles with optimized pitch length and pitch direction Conductor: Fine-wire strand

More information

Wires & Cables. Next is Ready TM. Marine Cables

Wires & Cables. Next is Ready TM. Marine Cables Next is Ready TM Marine Cables Index S.. Description 1.. Siechem Profile Siechem Manufacturing, Laboratories & Testing Facilities 3. Siechem an early bird in Marine Cable segment in India 4. FAQ : Why

More information

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable CP Jacket (overall optional) Armor (optional) CP Jacket Flexible Tin Coated Copper ed Color Coded XLPO Polyolefin Insulation 600/1000 volts Features Engineered for easiest installation. Extra flexible

More information

Data sheet chainflex CF270.UL.D

Data sheet chainflex CF270.UL.D For detailed overview please see design table 1. Outer jacket: Pressure extruded PUR mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic fleece 4. Core

More information

N2XY IEC XLPE PVC 0.6/1kV Cable

N2XY IEC XLPE PVC 0.6/1kV Cable N2XY IEC 60502-1 XLPE PVC 0.6/1kV Cable Eland Product Group: A2N APPLICATION These power and control cables are used for electricity supply in low voltage installation systems. They are well adapted to

More information

Type Approval Certificates for factories in Finland and China

Type Approval Certificates for factories in Finland and China 3 Type Approval Certificates for factories in Finland and China ABS BV CCS DNV GL KRS LRS RMRS NK RINA TC 0,6/1kV FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN FI CN LKM-HF LKM-HF FLEX LKSM-HF

More information

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable ed Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable Eland Product Group: A9L APPLICATION Multi-core LSZH cable with

More information

DNV-GL HH CE RoHS-II conform

DNV-GL HH CE RoHS-II conform Armour: Extremely bending- and torsion-stable aramid braid Armour: Extremely bending- and torsion-stable aramid wrapping Outer jacket: Pressure extruded PUR mixture Fibre: FOC-fibre made out of glass Subcable

More information

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL Photo: HELUKABEL Robotic Cables Robotic Cables With over 30 years of experience with cables and lines, we also have the right solutions for the demands placed on the components to be installed by the applications

More information

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) 600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore) FGD400 1RV-R (CU/XLPE/PVC 600/1000V Class 2) Outdoor Cabling Earth Conductor Earth Conductor APPLICATION The cables are mainly used in power

More information

600/1000V, PVC Insulated Cables according to IEC

600/1000V, PVC Insulated Cables according to IEC 8 Any inquiries, please feel free to contact 600/1000V, PVC Insulated s according to IEC 60502-1 Single core(unarmoured) Two core(unarmoured) Three core(unarmoured) Three core +1(unarmoured) Four core(unarmoured)

More information

CONTENTS. Introduction Customer Service Specification...5. Construction...6. Application...6. Technical Data

CONTENTS. Introduction Customer Service Specification...5. Construction...6. Application...6. Technical Data Content Page CONTENTS Page Introduction... 2 Customer Service... 3-4 Specification...5 Construction...6 Application...6 Technical Data...7-14 1.1 Unarmoured Cables with Overall Screened (TYPE 1)...7 1.2

More information

Building & Infrastructure Cables DELIVERING ENERGY

Building & Infrastructure Cables DELIVERING ENERGY Building & Infrastructure Cables DELIVERING ENERGY Keystone Cable is a Leading Singaporebased Cable Manufacturer and Supplier. Keystone Cable Market Reach Established since 1990, Keystone Cable has an

More information

Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc.

Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc. INTRODUCTION : Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc. Rubber is still considered the preferred insulation for

More information

o o blue-brown Fire Performance BS EN BS EN

o o blue-brown Fire Performance BS EN BS EN Standard Power Cables Low age (600/1000 V) Afumex 90 Armoured Power Cable Cable Approvals > Cable approved to BS6724 > Plain annealed copper stranded (Class 2) for ease of handling Insulation > 90 C -linked

More information

Chemical resistance Accidental

Chemical resistance Accidental Industrial flexible cable, insulation and outer sheath in elastomer. Oil resistant, flame retardant according to IEC/EN 60332-1-2 standard. Description Application flexible cable is intended for installations

More information

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems Overview Stranding.PVC.PUR.D (4x0,25)C (2x0,5)C.020 CF11.02.02.02.LC.D igus chainflex +++ chainflex cable works +++ (4x0,5)C.PVC.021.PUR.021.021 CF11.05.01.02.LC CF11.05.01.02.LC.D.PVC.022.PUR.022.022

More information

DURAREEL TRAILING REELING CABLE

DURAREEL TRAILING REELING CABLE Supplementary Technical Information Reeling and trailing material characteristics: A. Power core conductor Flexible strands tinned annealed copper complies with AS/NZS 1802, AS/NZS 2802, AS/NZS 1125, and

More information

Data sheet chainflex CF210.UL

Data sheet chainflex CF210.UL For detailed overview please see design table 1. Outer jacket: Pressure extruded, oil-resistant PVC mixture 2. Overall shield: Bending-resistant braiding made of tinned copper wires. 3. Banding: Plastic

More information

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD. Size (sq.mm.) Rate per 90m Coil 0.75 7 770 810 920 28 12 1 12 1000 1050 1200 24 12 1.5 16 1470 1540 1760 16 10 2.5 22 2370 2490 2840 12 6 4 29 3490 3670 4190 8 4 6 37 5200 5460 6240 6 3 10 51 9140 9600

More information

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY industrieblick / Fotolia Content page Who we are............................................................................................................

More information

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816 APPLICATION The cables are designed for use as connection between central fices. The cables are suitable for installation

More information

Submarine Power Cables

Submarine Power Cables Submarine Power Cables Submarine Power Cables Since decades Nexans plant in Hannover is specialised in the design, production and installation of low and medium voltage submarine power cables required

More information

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables Catalogue Introduction Nexans has developed a range of special and customised cables for the automotive market. This cable range covers two main

More information

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable Cat.6A, x-coded, 8-pole side 1: M12-jack, straight

More information

H07RN-F TITANEX PREMIUM

H07RN-F TITANEX PREMIUM New generation of flexible cables elastomer H07RN-F, born to release you from all the constraints. Thanks to its specific technology, it includes the properties of H07RN8-F; H07BN4-F; H07BB-F. Description

More information

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3 Corflex Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables Introduction................................. 2 Applications................................. 3 Corflex PL 300V Instrumentation

More information

20 HUBER+SUHNER RADOX SOLAR

20 HUBER+SUHNER RADOX SOLAR All our cables fully comply with the European directives 76/769/EWG, 2003/11/EG, 2000/53/EG, 2003/53/EG and 2002/95/EG (RoHS) and the requirements of REACH Nr. EC1907/2006. 20 RADOX SOLAR cables RADOX

More information

Installation cable, PVC insulated. Characteristics Properties Unit. Power cables < 1 kv House wiring cable

Installation cable, PVC insulated. Characteristics Properties Unit. Power cables < 1 kv House wiring cable According to VDE 0250 part 204 Characteristics Properties Unit Group Power cables < 1 kv Class House wiring cable Type material Cu, bare minal cross section conductor mm² Low smoke (acc. EN 61034-2) Diameter

More information

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements VDE tested single cores according to EN 50525-3-41 (H05Z-K & H07Z-K) for more demanding requirements ÖLFLEX HEAT 125 C MC - halogen free single core with GL certificate, special fire performance, IEC 60332-3,

More information

LIST OF PUBLISHED STANDARDS

LIST OF PUBLISHED STANDARDS Report : 08-0-6 Page o : Of 5 LST OF PUBLSHED STDRDS Total Count: 78 umber SS umber pproved mendment SBS/TC 066 SS 97:07 7.0 Electric cables - mpregnated paper-insulated 07-0-7 metal-sheathed cables for

More information

CLEVELAND CABLE LOCATIONS

CLEVELAND CABLE LOCATIONS A WORLD POWER IN CABLE SUPPLY THE CABLE AND ACCESSORY CATALOGUE 2010 2 CLEVELAND CABLE LOCATIONS CLEVELAND CABLE LOCATIONS 3 As is illustrated within our catalogue, we stock a comprehensive range of cables

More information

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY. INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn

More information