Typical 2 Bay Automatic Standard 2 Bay Using Trench Drain
|
|
- Jocelin Flowers
- 5 years ago
- Views:
Transcription
1 Typical Bay Automatic Standard Bay Using Trench Drain Trench Drain Slope to Removable P/T Wood Dam for Solids Containment Solid Cover Building Size Determine by location 3 Water Flow and Piping Legend. " PVC Drain Line from mud pits to reclaim tanks. Terminate with tee set horizontally.. " PVC Interconnect, plumb with tee set vertically, cap top clean out HP Pumps use Two PVC Sch 80 Suction Lines (one is a spare line) HP Pumps and greater use Two 3 PVC Sch 80 Suction Lines. ¼ PVC Ozone Return Line, terminate with tee set horizontally.. 3" PVC Backwash / Separator Return Line, terminate with elbow set horizontally.. / "PVC Overflow to Sanitary Sewer.
2 Tunnel Car Wash Layout PLEASE NOTE: The standard Tunnel Layout can be modified to locate the sump and " drain line to any location of the trough. The enclosed drawing shows the sump and return line at the end. The most important part of any recovery system is to have short pipe runs for both drain lines and suction lines. The normal pitch for the " return line is /" per foot from the trough to t he invert of Tank #. The suction lines from Tank #3 stubbed up at the location of the recovery unit in the filter system to the car wash equipment room and help eliminate the risk of suction. ' " 7' " ' " Building Size Determined by Location Equipment Room Water Flow and Piping Legend. " PVC Drain, terminate with tee. " PVC Invert, plumb with tees as cleanout 3. Two " SCH 80 Suction Lines, terminate with tee. ¼" PVC Ozone Return Line, terminate with tee. 3" PVC Backwash / Separator Drain Line 3 See attached sheet for Tank Details
3 Tunnel Car Wash Layout PLEASE NOTE: The standard Tunnel Layout can be modified to locate the sump and " drain line to any location of the trough. The enclosed drawing shows the sump and return line at the end. The most important part of any recovery system is to have short pipe runs for both drain lines and suction lines. The normal pitch for the " return line is /" per foot from the trough to the invert of Tank #. The suction lines from Tank #3 stubbed up at the location of the recovery unit in the filter system to the car wash equipment room and help eliminate the risk of suction leaks. If the underground tanks need to be located at the end of the car wash, locate the sump and return line at the same end. Equipment Room See Stub Up Drawing for location of Connections Water Flow and Piping Legend. " PVC Drain, terminate with tee. " PVC Invert, plumb with tees as cleanout 3. Two " SCH 80 Suction Lines (for HP-3HP systems) Two 3" SCH 80 Suction Lines (for HP-0HP systems). ¼" PVC Ozone Return Line, terminate with tee. 3" PVC Backwash / Separator Drain Line. " Overflow to Sanitary Sewer
4 TUNNEL CAR WASH LAYOUT WATER FLOW AND PIPING LEGEND. " PVC Drain, terminate with tee. " PVC Invert, plumb with tees as cleanout 3. Two " SCH 80 Suction Lines (for HP-3HP systems) Two 3" SCH 80 Suction Lines (for HP-0HP systems). ¼" PVC Ozone Return Line, terminate with tee. 3" PVC Backwash / Separator Drain Line. " Overflow to Sanitary Sewer SUMP RECLAIM SYSTEM 3 See Stub Up Drawing for location of Connections PLEASE NOTE: The Standard Tunnel Layout can be modified to any trough location of the sump and " drain line. This drawing shows the sump and return line in the CENTER of the wash. The most important part of any recovery system is to have short pipe runs for both drain lines and suction lines. The normal pitch for the " return line is ¼" per foot from the trough to the invert of Tank #. The suction lines from Tank #3 are stubbed up at the location of the recovery unit in the equipment room and help eliminate the risk of suction leaks. Determine if the tanks will be positioned at the entrance or exit end of the car wash location. If the tanks are located at the end then position the sump and the return line within the first half or entrance of the conveyor trough. The reclaim system and stub up pipes should be located in that entrance portion of the equipment room as well. If the tanks are at the end then locate the sump and return line at any point from the center of the trough to the exit. Locate the reclaim system close to the tanks. PLEASE NOTE THE TYPICAL EXAMPLES SHOWING THE TANKS, RETURN LINES & RECLAIM SYSTEM ALL IN CLOSE PROXIMITY. The shorter the suction lines, the higher the flow rates produced by the recovery system.
5 TYPICAL TUNNEL SHOWING BY-PASS DRAIN, MOVEABLE DAM FOR TIRE SHINE 0-0 WATER FLOW AND PIPING LEGEND. " PVC Drain, terminate with tee. " PVC Invert, plumb with tees as cleanout 3. Two " SCH 80 Suction Lines (for HP-3HP systems) Two 3" SCH 80 Suction Lines (for HP-0HP systems). ¼" PVC Ozone Return Line, terminate with tee. 3" PVC Backwash / Separator Drain Line. " Overflow to Sanitary Sewer Optional Dam is Used if Online Tire Dresser is Used Optional Dam Placement is Dependent on Location of Online Tire Shiner Equipment Room 3 0 See Stub Up Drawing for location of Connections PLEASE NOTE: The standard Tunnel Layout can be modified to locate the sump and " drain line to any location of the trough. This drawing shows the sump and return line in the CENTER of the wash. The most important part of any recovery system is to have short pipe runs for both drain lines and suction lines. The normal pitch for the " return line is /" per foot from the trough to the invert of Tank #. The suction lines from Tank #3 are stubbed up at the location of the recovery unit in the equipment room and help eliminate the risk of suction leaks. Determine if the tanks will be positioned at the entrance or exit end of the car wash location. If the tanks are located at the end then position the sump and the return line within the first half or entrance of the conveyor trough. The reclaim system and stub up pipes should be located in that entrance portion of the equipment room as well. If the tanks are at the end then locate the sump and return line at any point from the center of the trough to the exit. Locate the reclaim system close to the tanks. PLEASE NOTE THE TYPICAL EXAMPLES SHOWING THE TANKS, RETURN LINES & RECLAIM SYSTEM ALL IN CLOSE PROXIMITY. The shorter the suction lines the higher the flow rates produced by the recovery system.
6 TYPICAL FLOOD PUMP SYSTEM DIRECT IO N O F CA R T RAVEL TO EQ UIPM EN T BACKW ASH DRAIN FRO M SUM P SUCTIO N 000 G AL 00 G AL O UT TO SEW ER 3 0
Est The First, The Best, Built to Last... INSTALLATION MANUAL STABLE RELIABLE QUALITY
Est. 1948 The First, The Best, Built to Last... STABLE INSTALLATION MANUAL RELIABLE QUALITY 2007 STANDARD INSTALLATION DIAGRAM TRUSTY WARNS, INC 320 E. IRVING PARK RD. WOOD DALE, IL 60191 PH: 630-766-9015
More informationMCWW Tunnel Preventive Maintenance Weekly Evaluation Form
Car Wash Date Location Account # Car Count Phone: Fax: Contact: Service Provider Time In: Time Out: Downtime: Phone: Fax: Technician: MENU LIGHT OK DEFECT NOTES SIGN CLEANED TUNNEL WALK THROUGH GOOD DEFECT
More informationINSTALLATION GUIDE. Model #GB2 35/50 GPM Grease Interceptor For Indoor Use. Contents
INSTALLATION GUIDE Model #GB2 35/50 GPM Grease For Indoor Use Contents Special Precautions............................................ 2 Getting to Know the GB2....................................... 3
More informationINSTALLATION GUIDE. Model #PP1 Pumpout Port Kit For Use with Grease Interceptors Models GB1, GB2 and GB3. Contents
INSTALLATION GUIDE Model #PP1 Pumpout Port Kit For Use with Grease s Models GB1, GB2 and GB3 Contents Special Precautions............................................ 2 Getting to Know the PP1........................................
More informationBuilt-In Testing & Snap-On Overflow Plate Solvent Weld Assembly Coarse Thread: 11.5 = + 900NRI (ROUGH-IN) UP TO 16 FITTINGS - BUILT-IN BODY
Schedule 0 Built-In Testing & Snap-On Overflow Plate Solvent Weld Assembly Coarse Thread:. 00N Complete Bath Wastes Fits most tubs up to deep 00N Series PVC PP = Plastic Pin PP = Brass Pin COMPLETE BATH
More informationPRE-INSTALLATION GUIDE
Dry Vacuum System Part Numbers V3, V5, V7, 2V3, 2V3CT, 2V5, 2V5CT, 2V7, 3V5 and 4V5 PRE-INSTALLATION GUIDE All pumps comply with NFPA 99C level 3 requirements. All installations must conform to local codes.
More informationGB2 35/50 GPM Grease Interceptor for Indoor Use
INSTALLATION GUIDE GB2 35/50 GPM Grease for Indoor Use Contents Special Precautions.........................................2 Getting to Know the GB2....................................3 On the Floor Installation..................................
More informationA u t o matic Backw ater V alve
A u t o matic Backw ater V alve P R O TECT YOUR I N V E S TMENT S INDEX PAGE FLOOD-GATE FEATURES Flood-Gate Features and Applications 2 How Flood-Gate Works 3 Flood-Gate Operation & Approvals 4 Fully mechanical
More informationFlexible Couplings & Saddles
Revised 6/01 Flexible Sewer couplings are the result of many years of experience with sewer pipe connections. Today's couplings are made of specially formulated elastomeric PVC with high tear and shear
More informationPRESSURE UTILITIES. Pipe flow occurs due to contents of the pipe being pressurized System cannot have a free connection to the atmosphere
PRESSURE UTILITIES Pipe flow occurs due to contents of the pipe being pressurized System cannot have a free connection to the atmosphere Types of Pressure Utilities Domestic Water: Clean/drinkable water
More informationFor Conduit Inspections
Underground Conduit Standards - Table of Content 5/8/2017 Section S22 Underground Conduit Standard Index: Description: 00 Table of Content 01 General Notes 02 Definition of Terms 03 Primary Riser Conduit
More informationHALLMARK INDUSTRIES INC
Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge
More informationDWV PVC DWV Drain Waste Vent Fittings
STANDARDS & SPECIFICATIONS Standards provide greater assurance of product performance and consistency, and are available to assist design engineers in system specification. The most frequently referenced
More informationFLORIDA RURAL WATER ASSOCIATION 2970 Wellington Circle Tallahassee, FL Telephone: ~ Fax:
FLORIDA RURAL WATER ASSOCIATION 2970 Wellington Circle Tallahassee, FL 32309-6885 Telephone: 850-668-2746 ~ Fax: 850-893-4581 Lift Station Bypass Pump & Connection Assembly Instructions Loss of power during
More informationPOLAR ALUMINUM, ELLIPTICAL, TAPERED, BAFFLED, D.O.T. 406 TRAILER ATB
POLAR ALUMINUM, ELLIPTICAL, TAPERED, BAFFLED, D.O.T. 406 TRAILER ATB6 9500-5 15218-15221 2016 BARREL DESCRIPTION Model: ATB6 9500-5, aluminum, elliptical, tapered, baffled, DOT 406 trailer Code: DOT 406
More informationRAINWATER HARVESTING INSTALLATION GUIDE RH9508, RH9510, RH9511
RAINWATER HARVESTING INSTALLATION GUIDE RH9508, RH9510, RH9511 Please read these instructions carefully before installing the Filter Collector. RH9508 (WISY GRS 100) RH9510 (WISY FS) Instructions for installation
More informationBattery Backup Sump Pump System Instruction Manual
Battery Backup Sump Pump System Instruction Manual Push button second to test or reset alarm. Push 5 seconds to silence alarm for 24 hours. Warning alarms The fluid in the battery is low. Add distilled
More informationPOLAR ALUMINUM, ELLIPTICAL, TAPERED, BAFFLED, D.O.T. 406 TRAILER ATB
POLAR ALUMINUM, ELLIPTICAL, TAPERED, BAFFLED, D.O.T. 406 TRAILER ATB6 9500-5 14931-14933 2016 BARREL DESCRIPTION Model: ATB6 9500-5 Code: DOT 406 Capacity: 9500 gallons (up to +3% tolerance, 60 gallons
More informationINSTALLATION GUIDE. Model #GB1 20/25 GPM Grease Interceptor For Indoor Use. Contents
INSTALLATION GUIDE Model #GB1 20/25 GPM Grease For Indoor Use Contents Special Precautions............................................ 2 Getting to Know the GB1........................................
More informationSan Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS
San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS 834.1 DESCRIPTION: This item shall consist of fire hydrant installations using joint restraints in accordance
More informationElectric underground service installation requirements
MRCH 0 Electric underground service installation requirements CLL PSE S CUSTOMER CONSTRUCTION S T -888--9 OR VISIT PSE.COM/CUSTOMERCONSTRUCTION FOR MORE INFORMTION. Builder/owner/developer responsibilities
More informationBATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM
BATTERY WASH CABINETS, WASH STATIONS, RECIRCULATION/NEUTRALIZATION SYSTEM Complete Product Line A cost-effective solution for extending the life of batteries and reducing lift truck electrical problems
More informationMASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL
MASTER COALESCER JR & PORTABLE MASTER COALESCER JR AIR PUMP MODEL INSTALLATION MANUAL INSTALLATION: CHOOSING THE LOCATION: Locate the coalescer as near to the intended point of use as possible. Avoid high
More informationSALEM CITY POWER ELECTRICAL REQUIREMENTS & STANDARDS MANUAL
SALEM CITY POWER DEPARTMENT TABLE OF CONTENTS Section 1 General Requirements Purpose...1.1 Codes and Ordinances...1.1 Changes or Conflicts in Requirements and Guidelines...1.1 Application for Service...1.2
More informationSOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS
SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS November 17, 2016 Engineering Service Specifications Table of Contents Commercial Service Requirements SLEMCO Commercial
More informationSan Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS
San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS 834.1 DESCRIPTION: This item shall consist of fire hydrant installations using joint restraints in accordance
More informationThe BEST Plumbing Specialties. One Source. L-21 TEST PLUgS
_plumberstools:pcsectionj.qxd 2/6/2012 4:51 PM Page -21 The BEST Plumbing Specialties. One Source. -21 TEST PUgS TEST PUg - SINgE SURE TEST TEST PUg - ONg SURE TEST - Maximum Back Pressure - Water: 30FT.
More informationWhiting Systems, Inc.
Storm SmartWash ash Touchless Gantry Whiting Systems, Inc. 9000 Highway 5 North Alexander, Arkansas 72002 800-542-9031 501-847-0074 fax The SmartW is ideal for washing irregular or standard vehicles such
More informationINDUSTRIAL WATER PROCESSING SYSTEMS CENTRAL BRINE DRUM INSTALLATION INSTRUCTIONS
INDUSTRIAL WATER PROCESSING SYSTEMS CENTRAL BRINE DRUM INSTALLATION INSTRUCTIONS Manufactured by: Kinetico Incorporated Newbury, OH 44065 440.564.9111 The pioneer in non-electric water processing systems.
More informationDragflow srl Via Pasubio, Vil afranca (VR) Italy tel fax products catalogue
Dragflow srl Via Pasubio, 40 37069 Villafranca (VR) Italy tel. +39.045.6304521 fax +39.045.6335758 info@dragflow.it www.dragflow.it products catalogue History Dragflow S.r.l. was born at the end of the
More informationDIGITAL FLOWMETER AND PRESSURE INDICATOR MODEL FPA400
Document Number: XE-FPA4PM-R0A FPA400 Rev160601 DIGITAL FLOWMETER AND PRESSURE INDICATOR MODEL FPA400 OPTIONAL BACKLIGHTING FIRE RESEARCH CORPORATION www.fireresearch.com 26 Southern Blvd., Nesconset,
More informationOver-Under Conveyor Soft-Drop
Owner s Manual Sonny's Enterprises, Inc. 5605 Hiatus Road Tamarac, Florida 33321 16v2 *Table of Contents* Equipment Program - Manuals WARNING *SAFETY REQUIREMENTS* WARNING... 3 *INTRODUCTION*... 5 Product
More informationSUPERSEDES ABS-C0811/AUG.
ABS-C0612/R JUNE 2012 SUPERSEDES ABS-C0811/AUG. 2011 SANITARY TEE REDUCING TEE TEE - Left Side Inlet 600007 1 1/4" 0 62852 60000 5 50 4,800 15.41 600015 1 1/2" 0 62852 60001 2 90 2,880 8.27 600023 2"
More informationPIPE CONNECTORS & ACCESSORIES
PIPE CONNECTORS & ACCESSORIES FLEXIBLE COUPLINGS Transitions cast iron or plastic to cast iron or plastic pipe. 300 series stainless steel clamps Complies with: ASTM C1173-2002 CSA B602-2005 IAPMO 4933
More informationPre-Installation 4 Point Checklist
Base Products Corporation www.basepump.com 800 554 1426 page 1 Installation Instructions for Basepump Model RB750-EZ Important: Complete this page before attempting installation of this product! Read all
More informationWater Use, Evaporation and Carryout Conveyor Car Washes
Water Use, Evaporation and Carryout Conveyor Car Washes By Chris Brown CHRIS BROWN CONSULTING 2018 CAR WASH WATER USE STUDY - CONVEYOR CAR WASHES 1 2 INTERNATIONAL CARWASH ASSOCIATION TABLE OF CONTENTS
More informationDEMA Nitro for Europe Ware Wash Chemical Dispensing
DEMA Nitro for Europe Ware Wash Chemical Dispensing Overview The DEMA Nitro is a digital ware wash dispenser designed to dispense cleaning chemicals when signals are received from ware wash and dish machines.
More informationStandards for Design and Construction
Standards for Design and Construction Of Water, Wastewater, Fiber optics and Reclaimed Water Facilities For Pasco County Utilities Department Revised: March 2018 Board of County Commissioners: Kathryn
More informationTHE GLOBAL LEADER IN PIPE PLUG & TESTING
THE GLOBAL LEADER IN PIPE PLUG & TESTING PNEUMATIC PLUGS MECHANICAL PLUGS GAUGES TOOLS & ACCESSORIES TESTING EQUIPMENT 2 Oatey.com/Cherne TEST WITH THE BEST CHERNE TABLE OF CONTENTS PNEUMATIC PLUGS BLOCKING
More informationPlugs & Test Equipment for Piping Systems
Plugs & Test Equipment for Piping Systems Catalog CHERNE INDUSTRIES INC. 800.843.7584 www.cherneind.com Publication Date Mar. 2017 Cherne Industries Best in the Business From Humble Beginnings to an Industry
More informationHanna Daily Preventive Maintenance Schedule
Hanna Daily Preventive Maintenance Schedule Location Location # Daily operation and inspection procedures to be performed by car wash personnel. Mark status in the spaces on the right after performing
More informationTypical installation, chassis grease
0 Typical installation, chassis grease Typical installations Bulk oil systems, motor oil.... Chassis grease... Pump and reel....0 Typical fast lube systems.... Lubrication truck accessories.... Two oil
More informationInstallation Manual. Automated Fuel. Maintenance. System FUEL TECHNOLOGIES INTERNATIONAL LLC
Installation Manual Automated Fuel Maintenance System FTI-10A & FTI-20A FUEL TECHNOLOGIES INTERNATIONAL LLC Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 03/01/2011 -
More informationINSTALLATION, OPERATING AND SERVICE MANUAL
INSTALLATION, OPERATING AND SERVICE MANUAL ECONO-mist WATER SOFTENER Demand Regeneration 7-LMC56-75B 7-LM56-75B 7-LM56-100B 7-LM56-150B 7-LM56-200B Congratulations on purchasing your new Lancaster Water
More informationPresentation Objectives Provide a description of how Directional Boring works Cover the basics for planning a Directional Bore Discuss the advantages
Directional Boring { An Introduction to the HDD Process Presentation Objectives Provide a description of how Directional Boring works Cover the basics for planning a Directional Bore Discuss the advantages
More informationB2. Fueling Operations
B2. Fueling Operations Commercial / Industrial / Institutional & Municipal Pollution Prevention Goal: Prevent or reduce the risk of discharge of pollutants to stormwater from vehicle and equipment fueling
More informationPLUMBING PARTS CATALOG
PREMIUM J0 PLUMBING PARTS CATALOG PUMP J0 Pump/Motor * 6 0 9 * 600- HOUSING: FRONT 600-90 O-RING: FRONT HOUSING 600-9 IMPELLER:. DIA 600-0 PUMP: SEAL ASSY / VITON 600- HOUSING: REAR BRACKET 6 600- MOTOR:.HP
More information2) Mark wall at 5 10 for center line of bottom bolt-hole in wall brackets on transition box side of floor.
IN-BAY INSTALLATION 1) Set up transit or level to determine highest point on the floor. From this point establish a level line from which to mark the bracket height on the walls. 2) Mark wall at 5 10 for
More informationEngineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes
Engineering Service Specifications Commercial Single-Phase Current Transformer Metering Schemes Specifications for Commercial Underground Current Transformer Metering Requirements for a Single-Phase Customer
More informationABS-C0717 JULY 2017 SUPERSEDES ABS-C0217 CSA B181.1 ABS DWV FITTINGS.
ABS-C0717 JULY 2017 SUPERSEDES ABS-C0217 CSA B181.1 ABS DWV FITTINGS www.bow-group.com dimension item Ctn Skid list price dimension item Ctn Skid list price SANITARY TEE (Hub x Hub x Hub) 1 1/4" 600007
More informationInitial Start-Up. What We Will Cover
03 03 Initial Start-Up Once you have a firm grasp on the components of the assembly head and drip line, it s time for the initial installation. When installing your head assembly, there are a few different
More informationCleaning Systems Inc. 2 P Rev:03
CHEMPOD Table of Contents Overview... 3 Specifications... 3 Dimensions... 3 Weight... 3 Electrical Voltage... 3 Capacity... 3 Product Supply... 3 Pneumatic Supply... 3 Optional Installation Kits... 3 Locating
More informationPumping Industry 101. THE DYNAMICS of pumping grease waste works and the responsibilities we carry
Pumping Industry 101 THE DYNAMICS of pumping grease waste works and the responsibilities we carry PUMP TRUCK PUMPING OF GREASE WASTE WORKS Different brands Different sizes Vacuum Pumps Different vacuum
More informationOil Water Separators Product Range
Industrial Water Treatment and Recycling Specialists Oil Water Separators Product Range 1800 353 788 www.cleanawater.com.au Oil Separators Total Range Cleanawater provide the largest range of oil water
More informationUnilift CC 7-A1 (240V,0.25kW, L/sec,1-7m)
Unilift CC 7-A (24V,.25kW,.4-2.6L/sec,-7m) Contents: Unilift CC 7 (9628974)... 2 Quotation text... 2 Quotation text incl. photo... 3 Data sheet incl. curve... 4 Pump curve... 5 Dimensional drawing... 6
More informationHydraulic Installation Guide
Hydraulic Installation Guide Version 1.0 Hydraulic Installation Guide - Version 1.0 Change Log Date Change 03/11/2014 Initial Release ABT-TRAC 517-A Martin Avenue Rohnert Park, CA 94928 Tel: 707-586-3155
More informationDry Vacuum System. Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL. Recommend Daily use of Monarch CleanStream
Dry Vacuum System Part Numbers: V15, 2V15, 3V15 and 4V15 USER S MANUAL Recommend Daily use of Monarch CleanStream TABLE OF CONTENTS Description Page Congratulations...3 Purpose of this Manual....3 Safety
More informationDIGITAL PRESSURE AND FLOW INDICATOR MODEL FPA500
Document Number: XE-FPA5PM-R0A FPA500 Rev150728 DIGITAL PRESSURE AND FLOW INDICATOR MODEL FPA500 FIRE RESEARCH CORPORATION www.fireresearch.com 26 Southern Blvd., Nesconset, NY 11767 TEL 631.724.8888 FAX
More informationSTANDARD DRAWING INDEX
ATTACHMENT B STANDARD DRAWING INDEX DESCRIPTION EXISTING DRAWING NO. GENERAL Typical Layout for Improvement Plans City of Stockton Standard Border and Title Block for 8 1/2 x11 Sheet City of Stockton Standard
More informationTYRE WASHING PLANTS. Certificate Number 5565 ISO 9001
TYRE WASHING PLANTS Hercules & Heracles Certificate Number 5565 ISO 9001 HERCULES and HERACLES are specially designed in order to wash the wheels and chassis of the vehicles leaving: construction sites,
More informationCommercial Systems. Unloading
Unloading Commercial Systems En Masse Mass-ter Mover Mass-ter Mover is pictured with 45 º corner, rack and pinion control, control pipe kit, center and intermediate wells. Klean Sweep has reducer drive
More informationSPARE PARTS MANUAL FOR TKF 4SC60 FOUR STRAND CONTINUOUS VERTICAL CONVEYOR
SPARE PARTS MANUAL FOR TKF 4SC60 FOUR STRAND CONTINUOUS VERTICAL CONVEYOR PREPARED BY: T.K.F. INC. 726 MEHRING WAY CINCINNATI, OHIO 45203 PHONE: (513) 241-5910 FAX: (513) 651-2792 WEBSITE: http:/www.tkf.com
More informationWater Wizard Arch. Service Manual W 34th St, Houston, TX
Water Wizard Arch Service Manual 5842 W 34th St, Houston, TX 77092 1.800.999.9878 1.713.683.9878 www.colemanhanna.com Find us on Facebook: /ColemanHannaCarwash 1.0 Installation The following information
More informationVM / VML COMPONENT PARTS CATALOGUE
VM / VML REFRIGERATION COMPRESSOR COMPONENT PARTS CATALOGUE Ver. 2002 HASEGAWA CONTENTS Model VM / VML Compressor Description Parts # Crankcase Component Parts External Casing Fittings Covers & Gaskets
More informationMotor City Wash Works Charity Auction Items List
Motor City Wash Works Charity Auction Items List Below is a listing of the auction items that will be offered at this year s event. Company Description MSRP Reserve Motor City Wash Works 100ft. XD Conveyor
More informationPVC WELL CASING & FITTINGS 20 FT. BELL-END /8 SDR21 REDUCING COUPLINGS STEEL WELL CASING & FITTINGS
Pipe Pipe & Well Casing FT. BELL-END 0 7 293 2 2 29 27 23 " SCH0 -/2" SDR7 " SDR2 " SCH0 " SCH0 FT. BELL-END 37 32 30 29 2 " SCH0 -/2" SDR7 -/" DR27. PVC WELL CASING & FITTINGS FT. BELL-END 003 7 -/ SDR2
More informationSan Antonio Water System WaterSaver Car Wash Application PART 1 - GENERAL INFORMATION TYPE OF FACILITY. Business Name of Wash Facility:
San Antonio Water System WaterSaver Car Wash Application PART 1 - GENERAL INFORMATION Business Name of Wash Facility: Wash Facility Physical Address: Owner: Address: City: State: ZIP Code: Phone: TYPE
More informationBattery Backup Sump Pump System
Instruction Manual & Safety Warnings Table of Contents Important Safety Warnings and Instructions Electrical precautions 1 Battery preparation 1 Battery precautions 1 Introduction Items included in system
More informationJACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018
JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018 GANADO OFFICE PHYSICAL ADDRESS: 8925 State Highway 111 E Ganado, TX 77962 Phone: (361)771-4400 BAY CITY OFFICE PHYSICAL ADDRESS: 100
More informationOperations Manual for. Model CW-MOD. By RGF Environmental Systems, Inc.
Operations Manual for Model CW-MOD By RGF Environmental Systems, Inc. Copyright @ 1997 RGF Environmental Systems Inc. All rights reserved Software Design and Implementation : Dale Birosh Documentation:
More informationABS-0918 SUPERSEDES ABS-0318 ASTM D2661 R/SEPT ABS DWV FITTINGS.
ABS-0918 SUPERSEDES ABS-0318 ASTM D2661 R/SEPT. 2018 ABS DWV FITTINGS www.bow-group.com COUPLING 1 1/4" 601112 125 9,000 5.63 1 1/2" 601120 125 9,000 3.48 2" 601138 100 4,800 4.65 3" 601146 45 1,440 13.07
More informationABS DWV FITTINGS ABS-1116 NOVEMBER 2016 SUPERCEDES ABS-1215 ASTM D2661
ABS DWV FITTINGS ABS-1116 NOVEMBER 2016 SUPERCEDES ABS-1215 ASTM D2661 COUPLING 1 1/4" 601112 125 9,000 3.36 1 1/2" 601120 125 9,000 2.25 2" 601138 100 4,800 3.03 3" 601146 45 1,440 8.49 4" 601153 25 800
More informationTS-6032 VURSA SERIES TUB / SHOWER 60-INCH MODEL TS-6032R ABF / ANS09-FLD. Rough-In Dimensions. 60 wide x 33-1/4 deep x 73-3/4 high (w/ 16-inch apron)
VURSA SERIES TUB / SHOWER TS-6032R ABF / ANS09-FLD 60-INCH MODEL TS-6032 Rough-In Dimensions wide x 33-1/4 deep x 73-3/4 high (w/ 16-inch apron) Finished Dimensions wide x 32 deep x 72-1/2 high (w/ 16-inch
More informationBMF TROUBLESHOOTING GUIDE
BMF TROUBLESHOOTING GUIDE This document contains troubleshooting guidelines for PEP's standard BMF filters with pumps. REFERENCE DOCUMENTS: W-X-0039 BMF Electrical Wiring Drawing WP0011 BMF Control Panel
More informationReverse Osmosis System
Reverse Osmosis System Service Manual 5842 W 34th St, Houston, TX 77092 1.800.999.9878 1.713.683.9878 www.colemanhanna.com Find us on Facebook: /ColemanHannaCarwash HANNA REVERSE OSMOSIS SYSTEMS Table
More informationSOUTH COVE PARK MULTI-COURT IMPROVEMENTS FOR OCONEE COUNTY PARKS, RECREATION AND TOURISM SENECA, SOUTH CAROLINA FEBRUARY 2018
Pursuant to agreement between, Inc. (HMW) and the party for which these documents have been prepared, these documents and all data, plans, specifications and other information contained herein are the
More informationBUILT SMART, CLEANS TOUGH!
BUILT SMART, CLEANS TOUGH! BUILT SMART, CLEANS TOUGH! We understand that our customers have their unique cleaning challenges. SoAX Cleaning Systems is a line of pressure washers and self-serve equipment
More informationPeerless Pump FIRE PUMPS. Horizontal Split-Case, Vertical Turbine, In-Line and End Suction. Sterling Fluid Systems (USA), Inc.
Peerless Pump FIRE PUMPS Split-Case, Vertical Turbine, In-Line and End Suction Sterling Fluid Systems (USA), Inc. Brochure B-1500 Fire Protection Fire Pump Units & Packaged Systems You have decided to
More informationBattery Backup Sump Pump System
Battery Backup Sump Pump System Instruction Manual & Safety Warnings Table of Contents Important Safety Warnings and Instructions Electrical Precautions 1 Battery Preparation 1 Battery Precautions 1 Introduction
More informationA/C-D/C Battery Backup Sump Pump System
A/C-D/C Battery Backup Sump Pump System PUSH to Test or Reset Instruction Manual & Safety Warnings Table of Contents Important Safety Warnings and Instructions Electrical precautions 1 Battery preparation
More informationALEXANDRIA, VIRGINIA PRINCE ST. SUITE 114. ADG, INC. COPYRIGHT c. PH
1600 PRINCE ST. SUITE 114 ALEXANDRIA, VIRGINIA 22314 PH. 703.549.9556 www.archdesigngroup.com ADG, INC. COPYRIGHT c C-1 1 2 3 4 5 6 E D Tie Prop. Sidewalk, Curb & Gutter Into Existing Prop. Storm Drain
More informationINSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS
INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS CONTENTS Introduction Safety Operating Principle System Installation Initial Startup System Operations Troubleshooting Maintenance
More informationSpecification Sheet Form Rev
10000 CDC S1 Sales Administration Use Only Quote Number Quote Revision Shop Order Number Serial Number(s) Date CUSTOMER SALESPERSON MODEL : Customer Name : Salesperson Name : 10000 CDC S1 PART NO./DRAWING
More informationTROXELL COMPANY, INC E. HWY. 114 RHOME, TEXAS 76078
GENERAL CONSTRUCTION TROXELL COMPANY, INC. Specification Sheet 9250GL (220bbl) DOT407, Aluminum, Double Conical, Single Compartment, Tandem Axle Crude, Oil Tank Trailer MODEL: TRX407AL-220-1-DC-2-P NV-1407
More informationInstruction Manual. Computer Controlled A/C - D/C Sump Pump System
Instruction Manual Computer Controlled A/C - D/C Sump Pump System Table of Contents Important Safety Instructions General.......................1 AC Power Requirements..........1 Personal Precautions.............1
More informationA/C-D/C Battery Backup Sump Pump System
A/C-D/C Battery Backup Sump Pump System Instruction Manual & Safety Warnings Table of Contents Important Safety Warnings and Instructions Electrical precautions 1 Battery preparation 1 Battery precautions
More informationExpedition vehicle MD67 / MAN TGM 4x4
Expedition vehicle MD67 / MAN TGM 4x4 UNICAT expedition vehicle MD67 MAN TGM 4x4 1 / 32 Chassis MAN TGM 18.240 4x4 Compact cab Wheel base 4500 mm (177 ) Engine performance 176 kw / 240 hp, Euro 3 Manual
More informationPERMANENT RESIDENTIAL UNDERGROUND SERVICE
CITY OF RICHLAND ENERGY SERVICES DEPARTMENT 505 Swift Boulevard, MS-21 Richland, WA 99352 Telephone (509) 942-7403 Fax (509) 942-7405 PERMANENT RESIDENTIAL UNDERGROUND SERVICE A. INTRODUCTION This guide
More informationABS lifting station Synconta
15975187GB (03/2006) 106800 GB Installation and Operating Instructions www.absgroup.com Installation and Operating Instructions 601 801 901 901L 902 902L Contents 1 General... 3 1.1 Application areas...
More informationINFRASTRUCTURE DESIGN STANDARDS FIGURES SECTION 2 SANITARY SEWER COLLECTION SYSTEMS
INFRASTRUCTURE DESIGN STANDARDS FIGURES SECTION 2 SANITARY SEWER COLLECTION SYSTEMS 2.1 Sanitary Sewer Design Sheet 2.2 Hydraulic Elements Graph for Circular Sewers 2.3 Standard Servicing Locations for
More informationPage 6 of 6 OUTLAW DIESEL EGR COOLER DELETE KIT W/INTAKE ELBOW L FORD POWERSTROKE
What s in the box 1 Exhaust Block-Off Plate 1 Exhaust Gasket 2 Coolant Line Plugs 1 Brass Barbed Hose Connector 1 Stand-off Spacer 4 M10-1.25 x 40 Hex Head Bolts (Exhaust Manifold) 2 M10-1.25 x 20 Hex
More informationA/C-D/C Battery Backup Sump Pump System
A/C-D/C Battery Backup Sump Pump System Instruction Manual & Safety Warnings Table of Contents Important Safety Warnings and Instructions Electrical precautions 1 Battery preparation 1 Battery precautions
More informationNortheast Ohio AWWA October 26, 2017
Northeast Ohio AWWA October 26, 2017 Introduction Karl Dickinson Regional Sales Manager Jack Doheny Companies Sell & Rent Vacuum Trucks, Sewer Cleaning Equipment, & Pipeline Inspection Systems 16 Service
More informationWater Treatment Plant Historical Timeline
Water Treatment Plant Historical Timeline 1874 The citizens of the the Village of Evanston, with a population of 3500, started to build a communal water system. The system consisted of a 16 inch intake
More informationSpecification Sheet Form Rev
Sales Administration Use Only Quote Name Quote Revision Shop Order Number Serial Number(s) Date Customer : Customer Name Salesperson : Salesperson Name Model : 38000L L23 S1 Hybrid Duty Petroleum Trailer
More informationP239-1 Supply Pumper Instructions
P239-1 Supply Pumper Instructions STOP! READ THIS SECTION NOW. The following information is critical to the proper installation and operation of this Oil Supply System! Read it carefully before starting
More informationINSTALLATION MANUAL STK-5500BO ACCESSORY: Sump Kit
INSTALLATION MANUAL STK-5500BO ACCESSORY: Sump Kit INSTALLATION MANUAL Follow these steps to ensure a simple installation of your new FASS ACCESSORY 1. Read the installation manual completely before attempting
More informationSeries description: Wilo-Drain TM/TMW/TMR 32
Series description: Wilo-Drain TM/TMW/TMR 32 H[m] 10 Wilo-Drain TM /TMR /TMW 32 8 6 TM 32/7 4 TM 32/8 TMW 32/8 2 TMW 32/11 TMR 32/8 TMR 32/11 0 0 2 4 6 8 10 12 Q[m³/h] Design Basement drainage pump, water-cooled
More informationDWV - PVC. PVC Drain, Waste & Vent Fittings. Includes: DWV - PVC - through 8 HVAC. List Prices. Effective: February 15, 2016
Discount Codes 07 DWV-PVC through 8 22 VAC DWV - PVC PVC Drain, Waste & Vent Fittings Includes: DWV - PVC - through 8 VAC s Effective: February 15, 2016 Revised 2/29/2016 x FPT x MPT SP x MPT SP x SJ w/plastic
More informationTHE BayWash i5 BY OASIS SPEED 2 MINUTES TO A CLEAN, DRY, SHINY CAR - BY DESIGN
THE BayWash i5 BY OASIS It s hard to find fault with a business model that requires practically no labor, is relatively easy to construct, and uses only a small amount of space. Delivering 24 hour convenience,