FSM Electrical heating cable for frost protection or temperature maintenance of instrument lines and pipework in safe or hazardous locations

Size: px
Start display at page:

Download "FSM Electrical heating cable for frost protection or temperature maintenance of instrument lines and pipework in safe or hazardous locations"

Transcription

1 FSM Eectrica heating cabe for frost protection or temperature maintenance of instrument ines and pipework in safe or hazardous ocations FREEZSTOP MICRO Sef-Reguating Heating Tape Automaticay adjusts heat output in response to increasing or decreasing pipe temperature Can be cut-to-ength with no wastage Fu range of contros and accessories Approved for use in non-hazardous, hazardous and corrosive environments Wi not overheat or burnout, even when overapped Idea for fitting to instrument ines and sma diameter pipes Avaiabe up to 277VAC FEATURES Freezstop Micro is an industria grade sef-reguating heating cabe that can be used for freeze protection or temperature maintenance of pipework and vesses. It is particuary suited to sma diameter pipes and instrument tubing such as impuse or anayser ines. It can be cut-to-ength at site and exact piping engths can be matched without any compicated design considerations. Freezstop Micro is approved for use in non-hazardous and hazardous areas to word wide standards. Its sef-reguating characteristics improve safety and reiabiity. Freezstop Micro wi not overheat or burnout, even when overapped upon itsef. Its power output is sef-reguated in response to the pipe temperature. The instaation of Freezstop Micro is quick and simpe and requires no specia skis or toos. Termination, spicing and power connection components are a provided in convenient kits. OPTIONS Buswires Inherenty temperature-safe sef-reguating matrix Thermopastic eectrica insuation Continuous conductive covering of meta braid (-C) FSM-C Continuous conductive covering of meta braid. FSM-CT FSM-CF Thermopastic outer jacket over a meta braid provides additiona protection. Fuoropoymer outer jacket over a meta braid provides protection where corrosive chemica soutions or vapours may be present. Thermopastic or fuoropoymer outer jacket

2 R SPECIFICATION MAXIMUM CONTINUOUS EXPOSURE TEMPERATURE (Power ON) MAXIMUM PERMISSIBLE EXPOSURE TEMPERATURE (Power OFF) MINIMUM OPERATING TEMPERATURE MIN INSTALLATION TEMPERATURE POWER SUPPLY TEMPERATURE CLASSIFICATION MAXIMUM RESISTANCE OF PROTECTIVE BRAIDING 65 C (149 F) 85 C (185 F) -65 C* (-85 F) -40 C (-40 F) 0 277VAC T6 (85 C) 18.2 Ohm/km WEIGHTS AND DIMENSIONS Type Nomina Weight Min. Gand Ref Dimensions kg/100m Bending Size (mm) radius FSM-CT 10.5 x mm M20 FSM-CF 10.5 x mm M20 APPROVAL DETAILS Testing Authority ATEX Certificate No. Sira 02ATEX3075 IECEx SIR F M FM CSA EAC* ORDERING INFORMATION Exampe APPROVED Output 17W/m at 5 C Freezstop Micro Suppy Votage VAC Meta Braid Thermopastic Outerjacket TC RU C-GB.ГБ05.B F S M 2 - C T MAXIMUM LENGTH (m) vs. CIRCUIT BREAKER SIZE Cat Start-up 230V Ref Temperature 6A 10A 16A 20A 11FSM 5 C C C C FSM 5 C C C C Using circuit breaker Type C to IEC THERMAL RATINGS Nomina power output at 230V when FSM is instaed on insuated metaic pipes and as outined in the procedures within IEC and IEC W/m FSM 11FSM Pipe temperature ( o C) Note: Pease refer to Evoution for more precise power output vaues as a function of pipe temperature. ACCESSORIES We suppy a compete range of accessories incuding termination/spice kits, end seas, junction boxes and contros. These items are recommended for the correct operation of FSM products. Thermeec Limited, Od Naas Road, Buebe, Dubin 12, Ireand. Te: +353 (1) Fax: +353 (1)

3 FSLe Eectrica heating cabe for frost protection or temperature maintenance of instrument ines and pipework in safe or hazardous ocations FREEZSTOP LITE Sef-Reguating Heating Tape Automaticay adjusts heat output in response to increasing or decreasing pipe temperature Approved for use in non-hazardous, hazardous and corrosive environments Can be cut to ength with no wastage Fu range of contros and accessories Wi not overheat or burnout, even when overapped Avaiabe up to 277 VAC FEATURES Freezstop Lite is a ight industria/commercia grade sefreguating heating cabe that can be used for freeze protection or temperature maintenance of pipework and vesses in the construction and refrigeration industries. It can be cut-to-ength at site and exact piping engths can be matched without any compicated design considerations. Freezstop Lite is approved for use in non-hazardous, hazardous and corrosive environments to word wide standards. Its sef-reguating characteristics improve safety and reiabiity. Freezstop Lite wi not overheat or burnout, even when overapped upon itsef. Its power output is sef-reguated in response to the pipe temperature. The instaation of Freezstop Lite is quick and simpe and requires no specia skis or toos. Termination, spicing and power connection components are a provided in convenient kits. OPTIONS FSLe - C Continuous conductive covering of meta braid providing mechanica protection or where traced equipment does not provide an effective earth path. eg. pastic pipework. FSLe - CT Thermopastic overjacket over meta braid provides additiona protection. FSLe - CF Fuoropoymer overjacket over meta braid provides protection where corrosive chemica soutions or vapours may be present. Buswires Inherenty temperature-safe sef-reguating matrix Thermopastic eectrica insuation Continuous conductive covering of meta braid (-C) Thermopastic or fuoropoymer outer jacket

4 R SPECIFICATION MAXIMUM CONTINUOUS EXPOSURE TEMPERATURE (Power ON) 85 C (185 F) MAXIMUM PERMISSABLE EXPOSURE 85 C (185 F) TEMPERATURE (Power OFF) MINIMUM OPERATING TEMPERATURE 65 C* ( 85 F) MINIMUM INSTALLATION TEMP. 40 C ( 40 F) POWER SUPPLY 0 277VAC TEMPERATURE up to nom votage - T6 (85 C) CLASSIFICATION up to 25W/m@nom 230V powered to 277V - T6 (85 C) nom votage -T4 (135 C) nom 230V powered up to 277V -T4 (135 C) MAXIMUM RESISTANCE OF PROTECTIVE BRAIDING WEIGHTS AND DIMENSIONS 18.2 Ohm/km Type Nomina Weight Min. Gand Ref Dimensions kg/100m Bending Size (mm) radius FSLe 8.5 x mm M20 FSLe.. C 9.3 x mm M20 FSLe.. CT 10.5 x mm M20 FSLe.. CF 10.1 x mm M20 APPROVAL DETAILS Testing Authority Certificate No. ATEX Sira 02ATEX3074 IEC SIR F M FM VDE CSA DNV-GL EAC* APPROVED E12832 ORDERING INFORMATION Exampe Output 12W/m at 5 C Freezstop Lite Suppy Votage VAC Meta Braid Thermopastic Outerjacket TC RU C-GB.ГБ05.B F S L e 2 - C T MAXIMUM LENGTH (m) vs. CIRCUIT BREAKER SIZE Cat Start-up 230V Ref Temperature 6A 10A 16A 20A 12FSLe 5 C C C C FSLe 5 C C C C FSLe 5 C C C C FSLe 5 C C C C For use with Type C circuit breakers to IEC THERMAL RATINGS Nomina output at 115V or 230V when FSLe is instaed on insuated metaic pipes and as outined in the procedures within IEC and IEC W/m FSLe 23FSLe 17FSLe 12FSLe Pipe temperature ( o C) Note: Pease refer to Evoution for more precise power output vaues as a function of pipe temperature. ACCESSORIES We suppy a compete range of accessories incuding termination/spice kits, end seas, junction boxes and contros. These items are recommended for the correct operation of FSLe products. Thermeec Limited, Od Naas Road, Buebe, Dubin 12, Ireand. Te: +353 (1) Fax: +353 (1)

5 FSR Eectrica heating cabe for freeze protection of pipework and vesses in safe or hazardous ocations FREEZSTOP REGULAR Sef-Reguating Heating Tape Automaticay adjusts heat output in response to increasing or decreasing pipe temperature Approved for use in non-hazardous, hazardous and corrosive environments Can be cut to ength with no wastage Fu range of contros and accessories Wi not overheat or burnout, even when overapped Avaiabe up to 277VAC FEATURES Freezstop Reguar is an industria grade, sef-reguating heating cabe that can be used for freeze protection or temperature maintenance to 85 C. It can be cut to ength on site and exact piping engths can be matched without any compicated design considerations. Freezstop Reguar is approved for use in non-hazardous, hazardous and corrosive environments to word wide standards. Its sef-reguating characteristics improve safety and reiabiity. Freezstop Reguar wi not overheat or burnout, even when overapped upon itsef. The instaation of Freezstop Reguar heating tape is quick and simpe and requires no specia skis or toos. Termination, spicing and power connection components are a provided in convenient kits. Buswires Inherenty temperature-safe sef-reguating matrix Thermopastic eectrica insuation OPTIONS FSR - C FSR - CT FSR - CF Continuous conductive covering of meta braid for non-hazardous areas, hazardous areas or where traced equipment does not provide an effective earth path, eg. pastic pipework. Thermopastic overjacket over meta braid provides additiona protection. Fuoropoymer overjacket over meta braid provides protection where corrosive chemica soutions or vapours may be present. Continuous conductive covering of meta braid (-C) Thermopastic or fuoropoymer outer jacket

6 R SPECIFICATION MAXIMUM CONTINUOUS EXPOSURE TEMPERATURE (Power ON) 85 C (185 F) MAXIMUM PERMISSABLE EXPOSURE 85 C (185 F) TEMPERATURE (Power OFF) MINIMUM OPERATING TEMPERATURE 65 C* ( 85 F) MINIMUM INSTALLATION TEMP. 40 C ( 40 F) TEMPERATURE up to nom votage - T6 (85 C) CLASSIFICATION up to 31W/m@nom votage powered to 277V- T6 (85 C) nom votage -T4 (135 C) nom 230V powered up to 277V -T4 (135 C) POWER SUPPLY MAXIMUM RESISTANCE OF PROTECTIVE BRAIDING 0 277VAC 18.2 Ohm/km WEIGHTS & DIMENSIONS Type Nom. Dims. Weight Min. Bending Gand Ref (mm) kg/100m radius Size FSR 10.9 x mm M20 FSR.. C 11.8 x mm M20 FSR.. CT 13.1 x mm M20 FSR.. CF 13.1 x mm M20 APPROVAL DETAILS Testing Authority ATEX Certificate No. Sira 02ATEX3070 IECEx SIR F M FM VDE CSA EAC* APPROVED ORDERING INFORMATION TC RU C-GB.ГБ05.B MAXIMUM LENGTH (m) vs. CIRCUIT BREAKER SIZE Cat Start-up 230V Ref Temperature 6A 10A 16A 20A 25A 10FSR 10 C C C C FSR 10 C C C C FSR 10 C C C C FSR 10 C C C C FSR 10 C C C C For use with Type C circuit breakers to IEC THERMAL RATINGS Nomina output at 115V or 230V when FSR is instaed on insuated metaic pipes and as outined in the procedures within IEC and IEC W/m 40FSR 31FSR 25FSR 17FSR 10FSR Exampe Output 17W/m at 10 C Freezstop Reguar Suppy Votage V AC Meta Braid Thermopastic Outerjacket 17FSR2-CT Pipe Temperature ( o C) Note: Pease refer to Evoution for more precise power output vaues as a function of pipe temperature. ACCESSORIES We suppy a compete range of accessories incuding termination/spice kits, end seas, junction boxes and contros. Such items carry separate approvas from the heating tapes. When used in hazardous areas, ony use approved components. Thermeec Limited, Od Naas Road, Buebe, Dubin 12, Ireand. Te: +353 (1) Fax: +353 (1)

7 FSE(w) Eectrica heating cabe for freeze protection or temperature maintenance of pipework and vesses in safe or hazardous ocations FREEZSTOP EXTRA Sef-Reguating Heating Tape Automaticay adjusts heat output in response to increasing or decreasing pipe temperature Approved for use in non-hazardous, hazardous and corrosive environments Can be cut to ength with no wastage Fu range of contros and accessories Wi not overheat or burnout, even when overapped Avaiabe up to 277VAC FEATURES Freezstop Extra is an industria grade, sef-reguating heating cabe that can be used freeze protection or temperature maintenance to 100 C. It can be cut to ength on site and exact piping engths can be matched without any compicated design considerations. Freezstop Extra is approved for use in non-hazardous and hazardous areas to word wide standards. Its sef-reguating characteristics improve safety and reiabiity. Freezstop Extra wi not overheat or burnout, even when overapped upon itsef. The instaation of Freezstop Extra heating tape is quick and simpe and requires no specia skis or toos. Termination, spicing and power connection components are a provided in convenient kits. Buswires Inherenty temperature-safe sef-reguating matrix Thermopastic eectrica insuation OPTIONS FSE(w) - C FSE(w) - CT FSE(w) - CF Continuous conductive covering of meta braid for where traced equipment does not provide an effective earth path, eg. pastic pipework Thermopastic overjacket over meta braid provides additiona protection. Fuoropoymer overjacket over meta braid provides protection where corrosive chemica soutions or vapours may be present. Continuous conductive covering of meta braid (-C) Thermopastic or fuoropoymer outer jacket

8 SPECIFICATION MAXIMUM CONTINUOUS EXPOSURE TEMPERATURE (Power ON) MAXIMUM PERMISSABLE EXPOSURE TEMPERATURE (Power OFF) MINIMUM OPERATING TEMPERATURE MINIMUM INSTALLATION TEMP. POWER SUPPLY TEMPERATURE CLASSIFICATION MAXIMUM RESISTANCE OF PROTECTIVE BRAIDING 100 C (212 F) 100 C (212 F) 65 C* ( 85 F) 40 C ( 40 F) VAC up to nom votage - T4 (135 C) nom 230V powered up to 277V - T3 (200 C) 18.2 Ohm/km WEIGHTS & DIMENSIONS Type Nomina Weight Minimum Gand Ref Dimensions kg/100m Bending Size (mm) radius FSE 10.9 x mm M20 FSE - C 11.8 x mm M20 FSE - C* 12.3 x mm M20 FSEw 12.5 x mm M20 FSEw - C 13.5 x mm M20 FSEw - C* 15.0 x mm M25 * Denotes (T)hermopastic, or (F)uoropoymer outerjacket APPROVAL DETAILS Testing Authority ATEX Certificate No. FSE: Sira 02ATEX3076 FSEw: Sira 12ATEX3114 IECEx FSE: SIR FSEw: SIR EAC* DNV-GL TC RU C-GB.ГБ05.B E12833 MAXIMUM LENGTH (m) vs. CIRCUIT BREAKER SIZE Cat Start-up 230V Ref Temperature 6A 10A 16A 20A 25A 17FSE 10 C C C C FSE 10 C C C C FSEw 10 C C C C FSEw 10 C C C C For use with Type C circuit breakers to IEC THERMAL RATINGS Nomina output at 115V or 230V when Freezstop Extra is instaed on insuated metaic pipes and as outined in the procedures within IEC and IEC W/m FSEw 45FSEw 31FSE 17FSE ORDERING INFORMATION Exampe Output 45W/m at 10 C Freezstop Extra Wide version (45 and 60W/m ony) Suppy Votage V AC Meta Braid Fuoropoymer Outerjacket 45FSEw2-CF Pipe Temperature ( C) Note: Pease refer to Evoution for more precise power output vaues as a function of pipe temperature. ACCESSORIES We suppy a compete range of accessories incuding termination/spice kits, end seas, junction boxes and contros. Such items carry separate approvas from the heating tapes. Thermeec Limited, Od Naas Road, Buebe, Dubin 12, Ireand. Te: +353 (1) Fax: +353 (1)

9 G-Trace Sef-Reguating Heating Tape GT & GTe Roof and gutter protection from snow and ice buid up Ambient temperature range +40ºC to -40ºC Can be cut-to-ength with no wastage Wi not overheat or burnout, even when overapped Inherenty temperature-safe. (ITS) Externa temperature contros not necessary THE PROBLEM Snow that has buit up on a roof wi start to met as a resut of either exposure to the sun or from heat rising from the buiding beow. As the meted snow runs from the roof into cod gutters and drain pipes, it can re-freeze forming ayers of ice that can continue to buid up unti the fow is bocked. This can resut in damaged drains and gutters. In addition, water can get into the roof and was of the buiding, eading to expensive structura damage such as broken roof ties, damaged paster and facades, etc. THE SOLUTION We have the soution in the form of G-Trace. This sef-reguating heating cabe is avaiabe in two specifications, standard GTe and GT giving increased mechanica resistance for use in more arduous conditions. As for choice pease refer to the seection guide on the back page of this data sheet. The sef-reguating characteristics of the heating tape means that the cabe can adjust it s heat output in accordance with the ambient temperature. In snow and icy water, the heating cabe operates at fu power. As the snow mets and the water drains away, G- Trace sef-reguates to haf power whie it dries. As it gets warmer, so G-Trace graduay reduces it s output. The G-Trace system is safe and reiabe, as sef-reguation prevents overheating, G-Trace can even be instaed in pastic gutters and with the UV resistant outer jacket, the heating cabe is protected from the sun s harmfu rays thus making it totay durabe and reiabe. G-Trace provides a cost effective, preventive maintenance soution to damaged roof tops and gutters and the system consumes no more power than it takes to prevent ice formation. Design and instaation of a G-Trace system is simpe as there are no fixed engths. The heating tape can be cut to ength during instaation. G-Trace is cut off the ree and paced in the gutter. The heating tape is suspended within the downpipe without the need for spacers. A systems - from the simpest to the most eaborate use the same components, thereby providing maximum fexibiity and ease of design. Buswires Inherenty temperature-safe sef-reguating matrix Thermopastic eastomer insuation Continuous conductive covering of meta braid Optiona outerjacket

10 SPECIFICATION OPERATING ENVIRONMENTAL RANGE AMBIENT TEMPERATURE RANGE MINIMUM INSTALLATION TEMP. +15ºC to -15ºC (+59ºF to +5ºF) +40 C to 40 C (+104ºF to -40ºF) -40 C ( 40 F) MAXIMUM LENGTH (m) vs. CIRCUIT BREAKER SIZE CAT START UP 230V REF TEMP 6A 10A 16A 20A 32A GT 10 C C C POWER SUPPLY WEIGHTS AND DIMENSIONS VAC (other votages avaiabe on request) Type Nomina Weight Min. Ref Dimensions kg/100m Bending (mm) radius GT 13.1 x mm GTe 10.5 x mm SELECTION GUIDE Considerations for Fitting and Use GTe GT Compex Systems Abrasive Environments Gutter Appications Downspout Appications Eevated Tensie Load Resistance to Torsiona Force Resistance to Cutting ORDERING INFORMATION Exampe G-Trace heating tape Suppy Votage VAC Optiona Fuoropoymer Outerjacket POWER OUTPUT In ice at 0 C In air at 0 C COLD START DATA (300 Second Rating) GT GTe GT 2- F 36W/m 18W/m Start at C Start Current Start at C Start Current (A/m) (A/m) 230V 230V CAT START UP 230V REF TEMP 6A 10A 16A 20A 32A GTe 10 C C C Note: Cabe sha not be energised beow 0ºC. For use with Type C circuit breakers to IEC THERMAL RATINGS Nomina output at rated votage Notes A B W/m C A B Temperature o C In snow and ice water, the heating tape wi operate at fu power. As the snow begins to met and the water drains away, the heating tape sef-reguates to haf power whie it dries. As it gets warmer, the heating tape wi reduce its power output. C -15 C C C C C C ACCESSORIES We suppy a compete range of accessories incuding termination/spice kits, end seas, junction boxes and contros. These items are recommended for the correct operation of G-Trace heaters. Thermeec Limited, Od Naas Road, Buebe, Dubin 12, Ireand. Te: +353 (1) Fax: +353 (1)

11 HW Eectrica heating cabe for temperature maintenance of hot water services in domestic and commercia buidings HOTWAT Sef-Reguating Heating Cabe Maintains hot water at desired temperature Highy economica Eiminates the need for return pipework and re-circuating pumps Hot water instanty avaiabe at each outet Fu range of contros and accessories Avaiabe for 220/240VAC Sef-reguating heater cannot overheat or burn out FEATURES When hot water taps are infrequenty used, the water that stays in the distribution pipework coos and is usuay run to waste before hot water from the storage cyinder arrives at the tap. The use of re-circuating systems usuay ony maintains the water temperature in the main pipes and doubes the amount of pipework from which heat, and therefore energy, is ost. Hotwat is a parae resistance, sef-reguating heating cabe designed to compensate for heat osses from hot water distribution systems. The heater comprises a semi-conductve sef-reguating heating eement which automaticay reduces its power output as the pipe temperature increases. Thus, the heater cannot overheat or burn out. By appying Hotwat to the pipework (beneath the therma insuation) heat osses are eiminated and the water is maintained at the required temperature. Further savings are achieved by removing the need for recircuating pipework together with pumps, vaves, etc. There are two Hotwat systems avaiabe. HW-R is simpy used to maintain the pipework at approximatey C, whist HW-P is used to maintain C during norma operation with an extra disinfection feature at timed intervas to reduce risks of egionea. The appication of Hotwat to insuated hot water pipework enabes hot water to be avaiabe at each tap and dramaticay improves the system efficiency compared with un-insuated re-circuating pipework systems. OPTIONS HW-R.. T Hotwat Reguar heating cabe with a thermopastic overjacket for maintaining the pipework at approximatey o C. Buswires Inherenty temperature-safe sef-reguating matrix Thermopastic eectrica insuation Continuous conductive covering of meta braid (-C) Thermopastic outerjacket HW-P.. T Hotwat Pus is a higher power output heating cabe with a thermopastic overjacket for maintaining the pipework between o C with the added benefit of therma disinfection.

12 SPECIFICATION MAX. PERMISSIBLE TEMPERATURE (ON or OFF) MINIMUM INSTALLATION TEMPERATURE POWER SUPPLY MAXIMUM RESISTANCE OF PROTECTIVE BRAIDING WEIGHTS & DIMENSIONS 100 C (212 F) 40 C ( 40 F) VAC (on demand VAC) 18.2 Ohm/km Tape Nom. Dims. Weight Min.Bending Type (mm) kg/100m Radius HW-x..T 13.1 x mm x Denotes Hotwat (R)eguar, or Hotwat (P)us APPROVAL DETAILS Testing Authority Certificate No. FM F M VDE ORDERING INFORMATION Exampe APPROVED Hotwat heating tape Hotwat Reguar stye Suppy votage VAC Overjacket ACCESSORIES HWR2- T We suppy a compete range of accessories incuding termination/spice kits, end seas, junction boxes and contros. These items are recommended for the correct operation of Hotwat products. MAXIMUM LENGTH (m) vs. CIRCUIT BREAKER SIZE Cat Start-up 230V Reference Temperature 6A 10A 16A 20A HW-R 18 o C o C HW-P 18 o C o C For use with Type C circuit breakers to IEC RECOMMENDED INSULATION THICKNESS (mm) Cat Maintain Pipe Size (mm) Ref Temperature HW-R 60 o C o C o C HW-P o C The above figures are based on the therma insuation having a K-vaue of 0.038W/mK at 36 C mid-point temperature. SYSTEM FEATURES HW-R HW-P Hot Water Locaised or Centraised Suppy System Centraised Temperature Contro System Fixed temperature Variabe temperature setting by Powertrim Therma Not Avaiabe D-BUG timer unit or Pasteurisation BMS (Buiding Management System) Circuit Temp. Not Avaiabe Contact Heat Trace Scanning Eectrica Suppy 230V 230V Typica Maintain 50, 55, or 60 C 45 C - 70 C Temperature Nomina Output 9W/m at 55 C 9.5W/m at 70 C

13 SNOMELT Sef-Reguating Heating Cabe Eectrica heating cabe for snow meting and ice prevention of roads, ramps and wakways Systems suited to the size of instaation Automaticay adjusts heat output in response to increasing or decreasing surface temperature Contros can provide high power for meting, or reduced power for ice prevention Simpe instaation in concrete Wi not overheat or burnout, even when overapped Can be cut-to-ength with no wastage FEATURES SnoMet is a sef-reguating heating cabe that can be used for snow meting and ice prevention of surfaces such as concrete roads, ramps and paths. It may aso be used on stairways, wakway gratings or oading docks. It can be cut to ength at site and exact engths can be matched without any compicated design considerations. Power output is sef-reguated in response to surface temperature. SnoMet cannot overheat and tends to reduce power when not needed. SnoMet is ideay suited for most genera snow and ice prevention appications. Instaations can be combined with Heat Trace s speciay deveoped high energy efficient contro systems that can appy fu power for meting and a reduced ower output for ice prevention. A SnoMet / PowerMatch Micro+ controed system can reduce operating costs by as much as 80% when compared with conventionay controed snow meting and ice prevention systems. Buswires Inherenty temperature-safe sef-reguating matrix Thermopastic eectric insuation Continuous conductive covering of meta braid (-C) OPTIONS SM-B SM-B/A SnoMet for a appications, ideay suited for use on car park ramps, access roads, wakways, access ramps, driveways, etc. SnoMet as above, but braid and outer jacket repaced with extruded auminium outer jacket, offering greater mechanica protection when required. Auminium Jacket Thermopastic outer jacket SM-B SM-B/A

14 SPECIFICATION MAXIMUM SURFACE 40 C (104 F) TEMPERATURE MINIMUM INSTALLATION 30 C ( 22 F) TEMPERATURE POWER VAC SUPPLY (other votages avaiabe on request) WEIGHTS & DIMENSIONS Type Nom. Dims. Weight Min.Bending Ref (mm) kg/100m Radius SM-B 15.0 x mm APPROVAL DETAILS Testing Authority Certificate No. GOST R POCC GB.AГ23.B03944 F M FM APPROVED POWER OUTPUT CURVE The foowing graph indicates the cabe performance when buried in concrete. For other conditions, refer to the Factors Tabe shown beow. SM-B Power Output (W/m) at 230V SM B 80 ORDERING INFORMATION Exampe SnoMet heating cabe Suppy Votage VAC Optiona auminium outer jacket SM- B 2 / A Surface Temperature ( o C) ACCESSORIES We suppy a compete range of accessories incuding termination/spice kits, end seas, junction boxes and contros. These items are recommended for the correct operation of SnoMet products. MAXIMUM LENGTH (m) vs. CIRCUIT BREAKER SIZE FACTORS For buria in: Power Output Mutipying Factor Sand (wet) W/m in concrete x 0.9 Meta Conduit W/m in concrete x 0.4 Pastic Conduit W/m in concrete x 0.3 Cat Start-up 230V Ref Temperature 6A 10A 16A 20A SM-B 10 C C For use with Type C circuit breakers to IEC Thermeec Limited, Od Naas Road, Buebe, Dubin 12, Ireand. Te: +353 (1) Fax: +353 (1)

15 CRH 0518 CRH - Sef-reguating eectrica heating cabe for contact rai / ive rai heating CONTACT RAIL HEATER Cut To Length - Parae Resistance Sef-Reguating Heating Cabe Outputs avaiabe up to 90W/m Avaiabe up to 750 vdc CRH is suppied in pre-terminated engths up to 152 metres Fu range of contros and accessories Suitabe for contact rais/ive/3rd rai systems CRH can aso be suppied on rees for cutting to ength as required FEATURES The CRH contact rai heater has been specificay deveoped for contact or 3rd/ive rais operating on up to 750 vot dc systems. CRH rai heater is designed to maintain the operationa integrity of rai networks, ensuring that contact rais are kept cear of snow and ice during adverse weather conditions. CRH may be suppied in singe engths up to 178 metres and fitted with 1.5 metre pre-terminated cod ead and remote end seas. It is suitabe for direct repacement of existing contact rai heaters and wi integrate with the majority of existing contact rai or ive heating systems. The heater is hed in pace on the rai using protective GRP ange or channe section and purpose made heavy duty rai cips. The instaation of CRH heating cabes is quick and simpe and requires no specia toos. The fitting of new or repacement heaters can be carried out quicky and safey with minimum track possession time and therefore minimum disruption to rai traffic. A system components are moduar to ensure fast and simpe instaation. CRH heating cabes and system components are suitabe for withstanding the hazards of a rai environment - such as severe and continuous vibration due to rai traffic, immersion in icy water, snow, weed kier formuations, diese ois, ubrication ois, oxaic acid and de-icing fuids. CRH heating cabes are abe to operate in free air, totay or partiay, without affecting the working ife of the heater. 1.81mm² stranded copper conductors Semi conductive heating matrix Fuoropoymer insuation Optiona auminium foi outerjacket Protective channe

16 SPECIFICATION MAXIMUM Un-energised 135 C (275 F) TEMPERATURE MINIMUM INSTALLATION TEMPERATURE 20 C ( 4 F) POWER OUTPUT 0 C 32 F) POWER SUPPLY CONSTRUCTION Heating Eement 600VDC Semi-conductive sef-imiting matrix Power Conductors Nicke pated copper 1.81mm 2 Primary Insuation Outer Jacket WEIGHTS & DIMENSIONS Fuoropoymer Auminium foi Type Nom. Dims. Weight Min. Bending Ref (mm) kg/100m radius (mm) CRH 13.0 x ORDERING INFORMATION Exampe - pre-terminated engths 90 CRH 6-152M ACCESSORIES We suppy a compete range of accessories incuding, connector bocks, anti-vibration pugs, rai cips, contro systems, power cabing. IMPORTANT NOTES The CRH Rai Heater shoud ony be fitted to rais using approved methods. The heating cabe shoud ony be terminated using the approved cod ead connection and the specia heat shrink boot and tubing. Connections must be of an approved type. Fu detais of a approved anciary and contro equipment is avaiabe on request. Instaation of the CRH heating cabes must be carried out in accordance with Code of Practice for the Instaation of Contact Rai Heating Systems. MAX. CIRCUIT LENGTH (M) vs. CIRCUIT BREAKER AT 600VDC Cat Ref Start-up 16A 20A 32A 50A Temperature 90CRH6 0 C C C For use with Type C circuit breakers to BS EN60898:1991 HEATER OUTPUT GRAPH Nomina Output 88W/m Heater type CRH Suppy Votage 600VDC 152m Heated ength Power Output vs Rai Temperature for 90CRH6 ATTACHING THE HEATER TO THE RAIL Heaters may be mounted on the rai using a channe section. For appications that use an auminium cad contact rai, an ange section is aso avaiabe. Speciay designed spring cips hod the heater and the channe, or ange, to the rai. A range of cips are avaiabe to suit a variety of different rai profies. Heater shown with channe section Power Output (W/m) Rai Temperature ( C) Heater shown with ange section Thermeec Limited, Od Naas Road, Buebe, Dubin 12, Ireand. Te: +353 (1) Fax: +353 (1)

17 FLV / FLVw Eectrica heating tape for frost protection or temperature maintenance of pipework and vesses. FREEZSTOP Low Votage Sef-Reguating Heating Tape Automaticay adjusts heat output in response to increasing or decreasing pipe temperature Can be cut to ength with no wastage FLV avaiabe in outputs 12W/m & 17W/m FLVw avaiabe in 30W/m Fu range of contros and accessories Avaiabe for 22/24VAC, and 11/12VAC Wi not overheat or burnout, even when overapped ATEX & IECEX certified for hazardous areas FEATURES Freezstop Low Votage is a ight industria/commercia grade sef-reguating heating tape that can be used for freeze protection or temperature maintenance of pipework and vesses in the construction and refrigeration industries. It can be cut-to-ength at site and exact piping engths can be matched without any compicated design considerations. Its sef-reguating characteristics improve safety and reiabiity. Freezstop Low Votage wi not overheat or burnout, even when overapped upon itsef. Its power output is sefreguated in response to the pipe temperature. The instaation of Freezstop Low Votage is quick and simpe and requires no specia skis or toos. Termination, spicing and power connection components are a provided in convenient kits. OPTIONS Buswires Inherenty temperature-safe Sef-reguating matrix Thermopastic eectrica insuation Continuous conductive covering of meta braid (-C) FLV.. C FLV.. CT FLV.. CF Continuous conductive covering of meta braid for non-hazardous areas, hazardous areas or where traced equipment does not provide an effective earth path. eg. pastic pipework. Thermopastic overjacket over meta braid provides additiona protection. Fuoropoymer overjacket over meta braid provides protection where corrosive chemica soutions or vapours may be present. Thermopastic or fuoropoymer outer jacket NOTE 30FLVw is generay for use with speciaist appications ony. 12/17FLV 30FLVw

18 SPECIFICATION MAX. PERMISSIBLE FLV 85 C (185 F) TEMPERATURE ON or OFF FLVw 85 C (185 F) MINIMUM OPERATING TEMPERATURE MINIMUM INSTALLATION TEMPERATURE POWER SUPPLY MAXIMUM RESISTANCE OF PROTECTIVE BRAIDING 65 C* ( 85 F) 40 C ( 40 F) 22 24AC or DC (11 12 Vot on request) WEIGHTS AND DIMENSIONS (12 & 17FLV ony) 18.2 Ohm/km Type Nomina Weight Min. Gand Ref Dimensions kg/100m Bending Size (mm) C FLV 8.5 x mm M20 FLV.. C 9.3 x mm M20 FLV.. CT 10.5 x mm M20 FLV.. CF 10.5 x mm M20 APPROVAL DETAILS Testing Authority ATEX Certificate No. FLV Sira 12ATEX3115 FLVw Sira 12ATEX3113 MAXIMUM LENGTH (m) vs. CIRCUIT BREAKER SIZE CAT START START UP 24V REF UP TEMP CURRENT 6A 10A 16A 12FLV 5 C A/m C A/m C A/m C A/m FLV 5 C A/m C A/m C A/m C A/m For use with Type C circuit breakers to IEC second rating. Important Note 30FLVw 30 FLVw is used for speciaist appications ony. THERMAL RATINGS Nomina output at 12V or 24V when FLV is instaed on insuated meta pipes. W/m IECex FLV SIR FLVw SIR FLVw EAC* TC RU C-GB.ГБ05.B FLV ORDERING INFORMATION Exampe 12F L V 2 - C T FLV Output 12W/m at 5 C Freezstop Low Votage Suppy Votage 22 24VAC Tinned Copper Braid Thermopastic Outerjacket Pipe temperature ( o C) ACCESSORIES We suppy a compete range of accessories incuding termination/spice kits, end seas, junction boxes and contros. These items are recommended for the correct operation of FLV products. Thermeec Limited, Od Naas Road, Buebe, Dubin 12, Ireand. Te: +353 (1) Fax: +353 (1)

19 FSS Very high temperature sef-reguating heating cabe. 225ºC FaiSafe Super Inherenty Temperature-Safe Heating Cabe 225ºC exposure temperature withstand, (energised or switched off). Inherenty temperature-safe. (ITS) High power outputs to 75W/m at 10ºC Externa temperature contros not necessary. DESCRIPTION FSS is a very high temperature sef-reguating heating cabe, having an exposure imit of 225ºC, energised or not. It may be provided with a continuous extruded meta jacket for appications where high mechanica strength is required or a meta braid where fexibiity is preferred. The continuous meta outer jacket is ductie, yet withstands high mechanica oads, thus averting damage when being instaed in arduous environments. Easy terminations, cut-to-ength. Safest ever sef-reguating product range for very high temperature exposure; wi not overheat even when exposed to 225ºC when energised or switched off as it is inherenty temperature-safe. ATEX/ IECEx Approved Buswires. Inherenty temperature-safe sef-reguating matrix. Fuoropoymer eectrica insuation. Continuous meta jacket. (-A) or Meta braid. (-C) INHERENTLY TEMPERATURE-SAFE The inherent abiity to sef-reguate at a temperature eve beow the maximum product rating and withstand temperature of the insuating materias, without the need for temperature contro. Simiar competitor sef-reguating products are typicay imited to a maximum energised temperature, typicay 120ºC at which point, their retained power output prevent the cabe from sefreguating at its own imiting temperatures. A such products require temperature contro to ensure their own temperature safety. Optiona corrosion resisting fuoropoymer outer jacket. (-F) 0518

20 SPECIFICATION MAXIMUM CONTINUOUS EXPOSURE TEMPERATURE: (ENERGISED OR SWITCHED OFF) MINIMUM OPERATING TEMPERATURE: 225ºC (437ºF) -65ºC* (-85ºF) MAXIMUM LENGTH (m) vs. CIRCUIT BREAKER SIZE: The foowing circuit detais reate specificay for the trace heating of pipework and equipment. Cat Start-up 230V Reference Temperature 10A 16A 20A 32A MINIMUM INSTALLATION TEMPERATURE: -40ºC (-40ºF) POWER SUPPLY: 0-277V AC (other votages avaiabe on request) WEIGHTS & DIMENSIONS: Type Nom. Dims. Weight Min Bending Gand Ref (mm) kg/100m radius size FSS-A x mm M20 FSS-AF x mm M20 FSS-C x mm M20 FSS-CF x mm M20 APPROVAL DETAILS: ATEX - Sira 02ATEX3072 IECEx - SIR EAC* - TC RU C-GB.ГБ05.B CSA FM FSS 10ºC FSS 10ºC FSS 10ºC FSS 10ºC FSS 10ºC For use with Type C circuit breakers to IEC THERMAL RATINGS: Nomina output at 230V when FSS is instaed on thermay insuated carbon stee pipes, being fixed with auminium fixing tape. 80 ORDERING INFORMATION: Exampe; 30 FSS 2 - A or C option F FSS Output 30w/m at 10ºC FSS Heating Cabe Suppy Votage V AC Continuous Outer jacket Meta Braid Outer Sheath, Fuoropoymer FSS 45 FSS ACCESSORIES: We suppy a compete range of accessories incuding termination/spice kits, end seas, junction boxes and contros. Such items carry separate approvas from the heating cabes. Use ony approved components, as per system certification. W/m FSS 15 FSS Pipe Temperature (ºC) Thermeec Limited, Od Naas Road, Buebe, Dubin 12, Ireand. Te: +353 (1) Fax: +353 (1)

21 FS+ A high temperature sef-reguating heating cabe. 225ºC FaiSafe + Inherenty Temperature-Safe Heating Cabe 225ºC exposure temperature withstand, (energised or switched off). Inherenty temperature-safe. (ITS) Power outputs to 60W/m at 10ºC Externa temperature contros not necessary. DESCRIPTION FS+ is a high temperature sef-reguating heating cabe, having an exposure imit of 225ºC, energised or not. It may be provided with a continuous extruded meta jacket for appications where high mechanica strength is required or a meta braid where fexibiity is preferred. Buswires. Inherenty temperature-safe sef-reguating matrix. Siicone rubber eectrica insuation. The continuous meta outer jacket is ductie, yet withstands high mechanica oads, thus averting damage when being instaed in arduous environments. Easy terminations, cut-to-ength. Safest ever sef-reguating product range for high temperature exposure; wi not overheat even when exposed to 225ºC when energised or switched off as it is inherenty temperature-safe. ATEX/IECEx Approved. Continuous meta jacket. (-A) or meta braid. (-C) INHERENTLY TEMPERATURE-SAFE The inherent abiity to sef-reguate at a temperature eve beow the maximum product rating and withstand temperature of the insuating materias, without the need for temperature contro. Simiar competitor sef-reguating products are typicay imited to a maximum energised temperature, typicay 120ºC at which point, their retained power output prevent the cabe from sefreguating at its own imiting temperatures. A such products require temperature contro to ensure their own temperature safety. Optiona corrosion resisting outer jacket. (-S) or (-F) 0518

22 SPECIFICATION MAXIMUM CONTINUOUS EXPOSURE TEMPERATURE: (ENERGISED OR SWITCHED OFF) 225ºC (437ºF) MAXIMUM LENGTH (m) vs. CIRCUIT BREAKER SIZE: The foowing circuit detais reate specificay to the trace heating of pipework and equipment. MINIMUM OPERATING TEMPERATURE: -65ºC* (-85ºF) MINIMUM INSTALLATION TEMPERATURE: -40ºC (-40ºF) POWER SUPPLY: 0-277V AC WEIGHTS & DIMENSIONS: Type Nom. Dims. Weight Min Bending Gand Ref (mm) kg/100m radius Size FS+A x mm M20 FS+AS x mm M20 FS+AF x mm M20 FS+C x mm M20 FS+CS x mm M20 FS+CF x mm M20 APPROVAL DETAILS: ATEX - Sira 12ATEX3136 IECEx - SIR DNV-GL - E12834 EAC* - TC RU C-GB.ГБ05.B Cat Start-up 230V Reference Temperature 10A 16A 20A 32A 15FS+ 10ºC FS+ 10ºC FS+ 10ºC FS+ 10ºC For use with Type C circuit breakers to IEC60898 THERMAL RATINGS: Nomina output at 230V when FS+ is instaed on thermay insuated carbon stee pipes, being fixed with auminium fixing tape ORDERING INFORMATION: Exampe; 45 FS+ 2 - A or C S or F FS+ Output 45W/m at 10ºC FS+ Heating Cabe Suppy Votage V AC Continuous Meta Jacket Meta Braid Outer Sheath, Siicone Rubber Outer Sheath, Fuoropoymer ACCESSORIES: We suppy a compete range of accessories incuding termination/spice kits, end seas, junction boxes and contros. Such items carry separate approvas from the heating cabes. Use ony approved components, as per system certification W/m FS+ 30 FS+ 15 FS Pipe Temperature (ºC) Thermeec Limited, Od Naas Road, Buebe, Dubin 12, Ireand. Te: +353 (1) Fax: +353 (1)

23 AFS The words highest temperature sef-reguating heating cabe. 300ºC Auto FaiSafe Inherenty Temperature-Safe Heating Cabe 300ºC exposure temperature withstand, (energised or switched off). The words highest sef-reguating heating cabe, power output - 150W/m at 10ºC Inherenty temperature-safe. (ITS) Externa temperature contros not necessary. DESCRIPTION AFS is a high strength sef-reguating heating cabe having temperature and power capabiities beyond those of any competitor wordwide. Its imit of 300ºC, energised or not, is beyond the imits of conventiona poymers. Its high power capabiities (of up to 10ºC) makes it eminenty suited to medium and high temperature appications such as bitumen met-out. Its continuous meta jacket is ductie, yet withstands high mechanica oads, thus averting damage when being instaed in arduous environments. It is easy to terminate and cut-toength. AFS is the safest ever sef-reguating product for high temperature exposure; it wi not overheat even when exposed to 300ºC, when energised or switched off as it is inherenty temperature-safe. IECEx & ATEX Approva Pending. A safer, more convenient option to traditiona series resistance MI cabes, which must be individuay designed, are difficut to terminate and are not inherenty temperature-safe. Buswires. Inherenty temperature-safe sef-reguating matrix. High temperature siicone eectrica insuation. Continuous conductive covering of auminium. INHERENTLY TEMPERATURE-SAFE The inherent abiity to sef-reguate at a temperature eve beow the maximum product rating and withstand temperature of the insuating materias, without the need for temperature contro. Simiar competitor sef-reguating products are typicay imited to a maximum energised temperature, typicay 120ºC at which point, their retained power output prevent the cabe from sefreguating at its own imiting temperatures. A such products require temperature contro to ensure their own temperature safety. Optiona corrosion resisting outer jacket.

24 SPECIFICATION MAXIMUM EXPOSURE TEMPERATURE: 300ºC (572ºF) (ENERGISED OR SWITCHED OFF) * Limited to 275ºC when optiona fuoropoymer jacket is fitted. MAXIMUM LENGTH (m) vs. CIRCUIT BREAKER SIZE: The foowing circuit detais reate specificay for the trace heating of pipework and equipment. MINIMUM INSTALLATION TEMPERATURE: -40ºC (-40ºF) MINIMUM AMBIENT TEMPERATURE: -60ºC (-76ºF) POWER SUPPLY: WEIGHTS & DIMENSIONS: V AC (other votages avaiabe on request) Type Nom. Dims. Weight Min Bending Gand Ref (mm) kg/100m radius Size AFS x mm M25 AFS-F x mm M25 Cat Start-up 230V Reference Temperature 16A 20A 32A 63A 15AFS 10ºC AFS 10ºC AFS 10ºC AFS 10ºC AFS 10ºC AFS 10ºC AFS 10ºC For use with Type C circuit breakers to IEC APPROVAL DETAILS: ORDERING INFORMATION: IECEx (pending) ATEX (pending) THERMAL RATINGS: Nomina output at 230V when AFS is instaed on thermay insuated carbon stee pipes, being fixed with auminium fixing tape. 160 Exampe; 75 AFS 2 - F AFS Output 75w/m at 10ºC AFS Heating cabe Suppy Votage V AC Fuoropoymer outer jacket AFS AFS ACCESSORIES: We suppy a compete range of accessories incuding termination/spice kits, end seas, junction boxes and contros. Such items carry separate approvas from the heating cabes. Use ony approved components, as per system certification. W/m AFS 50 AFS AFS AFS Pipe Temperature (ºC) Thermeec Limited, Od Naas Road, Buebe, Dubin 12, Ireand. Te: +353 (1) Fax: +353 (1)

25 R FSU Extremey high temperature sef-reguating heating cabe. 250ºC FaiSafe Utimo Inherenty Temperature-Safe Heating Cabe 250ºC exposure temperature withstand, (energised or switched off). High power outputs to 100W/m at 10ºC Inherenty temperature-safe. (ITS) Externa temperature contros not necessary. DESCRIPTION Buswires. FSU is an extremey high temperature sef-reguating heating cabe, having an exposure imit of 250ºC, energised or not. Inherenty temperature-safe sef-reguating matrix. Easy terminations, cut-to-ength. Safest ever sef-reguating product range for extremey high temperature exposure; wi not overheat even when exposed to 250ºC when energised or switched off as it is inherenty temperature-safe. Fuoropoymer eectrica insuation. Meta braid. (-N) ATEX and IECEx Approved. INHERENTLY TEMPERATURE-SAFE The inherent abiity to sef-reguate at a temperature eve beow the maximum product rating and withstand temperature of the insuating materias, without the need for temperature contro. Simiar competitor sef-reguating products are typicay imited to a maximum energised temperature, typicay 120ºC at which point, their retained power output prevent the cabe from sefreguating at its own imiting temperatures. A such products require temperature contro to ensure their own temperature safety. Optiona corrosion resisting outer jacket. (-F) 0518

26 SPECIFICATION MAXIMUM EXPOSURE TEMPERATURE: 250ºC (482ºF) (ENERGISED OR SWITCHED OFF) MINIMUM OPERATING TEMPERATURE: -65ºC* (-85ºF) MINIMUM INSTALLATION TEMPERATURE: -40ºC (-40ºF) POWER SUPPLY: 0-277V AC WEIGHTS & DIMENSIONS: Type Nom. Dims. Weight Min Bending Gand Ref (mm) kg/100m radius Size FSU 10.1 x mm M20 FSU-N 11.4 x mm M20 FSU-NF 11.9 x mm M20 FSUw 12.4 x mm M25 FSUw-N 13.4 x mm M25 FSUw-NF 14.2 x mm M25 FSUw-A 14.2 x mm M25 FSUw-AF 15.0 x mm M25 APPROVAL DETAILS: ATEX - Sira 04ATEX3012, Sira 13ATEX3126 IECEx - SIR , SIR DNV-GL - E12835 CSA , EAC* - TC RU C-GB.ГБ05.B ORDERING INFORMATION: MAXIMUM LENGTH (m) vs. CIRCUIT BREAKER SIZE: The foowing circuit detais reate specificay for the trace heating of pipework and equipment. Cat Start-up 230V Reference Temperature 10A 16A 20A 32A 15FSU 10ºC FSU 10ºC FSU 10ºC FSU 10ºC FSU 10ºC FSUw 10ºC For use with Type C circuit breakers to BS EN60898: 1991 THERMAL RATINGS: Nomina output at 230V when FSU is instaed on thermay insuated carbon stee pipes, being fixed with auminium fixing tape FSUw Exampe; 75 FSU 2 - N F 90 Output 75W/m at 10ºC FSU Heating Cabe Suppy Votage V AC Meta Braid Outer Sheath, Fuoropoymer W/m FSU 60 FSU FSU ACCESSORIES: We suppy a compete range of accessories incuding termination/spice kits, end seas, junction boxes and contros. Such items carry separate approvas from the heating cabes. Use ony approved components, as per system certification. 30 FSU FSU Pipe Temperature (ºC) Thermeec Limited, Od Naas Road, Buebe, Dubin 12, Ireand. Te: +353 (1) Fax: +353 (1)

27 FSU+ Utra high temperature sef-reguating heating cabe. 275ºC FaiSafe U timo + Inherenty Temperature-Safe Heating Cabe 275ºC exposure temperature withstand, (energised or switched off). Very high power outputs to 125W/m at 10ºC Inherenty temperature-safe. (ITS) Externa temperature contros not necessary. DESCRIPTION FSU+ is an utra high temperature sef-reguating heating cabe, having an exposure imit of 275ºC, energised or not. FSU+ is provided with a continuous extruded meta jacket for appications where high mechanica strength is required. The continuous meta outer jacket is ductie, yet withstands high mechanica oads, thus averting damage when being instaed in arduous environments. Easy terminations, cut-to-ength. Buswires. Inherenty temperature-safe sef-reguating matrix. Fuoropoymer eectrica insuation Continuous meta jacket. (-A) Safest ever sef-reguating product range for very high temperature exposure; wi not overheat even when exposed to 275ºC when energised or switched off as it is inherenty temperature-safe. IECEx Approva Pending. INHERENTLY TEMPERATURE-SAFE The inherent abiity to sef-reguate at a temperature eve beow the maximum product rating and withstand temperature of the insuating materias, without the need for temperature contro. Simiar competitor sef-reguating products are typicay imited to a maximum energised temperature, typicay 120ºC at which point, their retained power output prevent the cabe from sefreguating at its own imiting temperatures. A such products require temperature contro to ensure their own temperature safety. Optiona corrosion resisting outer jacket. (-F)

28 SPECIFICATION MAXIMUM EXPOSURE TEMPERATURE: 275ºC (527ºF) (ENERGISED OR SWITCHED OFF) MINIMUM OPERATING TEMPERATURE: -65ºC (-85ºF) MINIMUM INSTALLATION TEMPERATURE: -40ºC (-40ºF) MAXIMUM LENGTH (m) vs. CIRCUIT BREAKER SIZE: The foowing circuit detais reate specificay for the trace heating of pipework and equipment. Cat Start-up 230V Reference Temperature 16A 20A 32A 50A 15FSU+ 10ºC POWER SUPPLY: 0-277V AC 30FSU+ 10ºC WEIGHTS & DIMENSIONS: Type Nom. Dims. Weight Min Bending Gand Ref (mm) kg/100m radius Size FSU+A 11.9 x mm M25 FSU+AF 12.7 x mm M25 FSU+w-A 14.2 x mm M25 FSU+w-AF 15.0 x mm M25 45FSU+ 10ºC FSU+ 10ºC FSU+ 10ºC FSU+w 10ºC FSU+w 10ºC For use with Type C circuit breakers to BS EN60898 APPROVAL DETAILS: ORDERING INFORMATION: IECEx (pending) THERMAL RATINGS: Nomina output at 230V when FSU is instaed on thermay insuated carbon stee pipes, being fixed with auminium fixing tape. Exampe; Output 75w/m at 10ºC FSU+ Heating Cabe Suppy Votage V AC Continuous Meta Jacket Outer Sheath, Fuoropoymer ACCESSORIES: 75 FSU+ 2 - A F W/m FSU+w 100 FSU+w 75 FSU+ We suppy a compete range of accessories incuding termination/spice kits, end seas, junction boxes and contros. Such items carry separate approvas from the heating cabes. Use ony approved components, as per system certification FSU+ 45 FSU FSU FSU Pipe Temperature (ºC) Thermeec Limited, Od Naas Road, Buebe, Dubin 12, Ireand. Te: +353 (1) Fax: +353 (1)

Innovation. Simplicity. is Simply Better. Rotary Lobe Pumps

Innovation. Simplicity. is Simply Better. Rotary Lobe Pumps Innovation Simpicity is Simpy Better Rotary Lobe Pumps So simpe, yet so diverse. Pease add. Six series with 19 sizes. AL-series PL-series CL-series FL-series EL-series XL-series A pump modes are manufactured

More information

Interact Overhead Power

Interact Overhead Power Interact Overhead Power 75 range introduction feature benefits Interact Overhead Power System is a powertrack catering for singe, 3 phase or dua circuit appications suitabe for standard, permanent ive,

More information

Clamping devices. CLAMPEX clamping elements offer new possibilities as a shaft-hub-connection:

Clamping devices. CLAMPEX clamping elements offer new possibilities as a shaft-hub-connection: Keyess camping devices Camping devices Genera description: CLAMPEX are keyess camping devices designed to transmit torque via friction on mating components. These designs produce high transmittabe torque

More information

Lintra-Lite Actuators Series A44000, Rodless Cylinders Double Acting

Lintra-Lite Actuators Series A44000, Rodless Cylinders Double Acting Section 11 Lintra-Lite Actuators Series A44000, Rodess Cyinders Doube Acting LINTRA -LITE Series A44000 Rodess Cyinders Series A44000 Features...ACT-11-2 Series A44000 Specifications...ACT-11-3 Series

More information

Thread Direction R = Right hand L = Left hand (Not Available for Micro Series) (Refer to leadscrew. Code. availability)

Thread Direction R = Right hand L = Left hand (Not Available for Micro Series) (Refer to leadscrew. Code. availability) Kerk onventiona s: FW Series Free Wheeing Kerk FW Series conventiona stye, without anti-backash function. The Kerk FW Series genera purpose free-wheeing nut is for appications not requiring anti-backash

More information

Any switch configuration

Any switch configuration Series L2 Rotary Cam es Attractive design, reiabe operation and high quaity for any appication up to 25 Amps TIP! Sprecher + Schuh s comprehensive ine of L2 rotary cam switches are avaiabe for a contro

More information

TD3 Series UNIQUE LIGHTING SOLUTIONS RETROFIT INSTALLATION GUIDE TD3-1-UN-65 TD3-3-UN-65

TD3 Series UNIQUE LIGHTING SOLUTIONS RETROFIT INSTALLATION GUIDE TD3-1-UN-65 TD3-3-UN-65 TD3-1-UN-65 TD3-3-UN-65 RETROFIT INSTALLATION GUIDE UNIQUE LIGHTING SOLUTIONS WARNING Retrofit instaation must ony be performed by a icensed eectrician. To prevent death, injury or damage to property this

More information

STEPPER DRIVE : E-5042

STEPPER DRIVE : E-5042 54, Annapurna Industria Estate, Tiak oad, E L E C T O N I C S Introduction The E-5042 is a fuy digita stepper drive deveoped with advanced DSP contro agorithm based on the atest motion contro technoogy.

More information

Ready for the future. ST 1082 mobile column lifts capacity kg

Ready for the future. ST 1082 mobile column lifts capacity kg Ready for the future ST 1082 mobie coumn ifts capacity 8.200 kg Two hard and fast aws appy in today s maintenance and repair faciities: time is money and an agreement is an agreement. This is why more

More information

Manifold Technology.

Manifold Technology. ----------------------------------------------------- 2017.2 Manifod Technoogy. made in Germany I Epkg. unitrything UNDER CONTROL. Manifod Technoogy - I BEULCO heating and cooing manifods made of high-quaity

More information

Product Information. Process pressure/hydrostatic Pressure transmitter VEGABAR 51, 52, 53, 54, 55

Product Information. Process pressure/hydrostatic Pressure transmitter VEGABAR 51, 52, 53, 54, 55 Product Information Process pressure/hydrostatic Pressure transmitter VEGABAR 5, 5, 5, 54, 55 Contents Contents Measuring principe.......................................................................................

More information

FREEZSTOP MICRO SYSTEM

FREEZSTOP MICRO SYSTEM FREEZSTOP MICRO SYSTEM Freeze Protection of Pipework Prevent Burst or Blocked Pipes The Problem Thermal insulation alone will not prevent freezing of pipes. For example, a 25mm diameter water pipe at +5

More information

Our policy is one of continuous research and development. We therefore reserve the right

Our policy is one of continuous research and development. We therefore reserve the right Tubing & Hose Metric Nyon, Poyurethane, Poyester Reinforced PVC, Meta Braided Rubber, Copper, Doube Wa Brazed Stee Avaiabe in a variety of different types to suit a wide range of appications A tubing can

More information

1

1 www.systems-sunight.com 1 2 www.systems-sunight.com SUNLIGHT s motive power (traction) batteries motivate your business, as they provide reiabe energy to your industria vehices every day. SUNLIGHT s speciaized

More information

INSTRUCTION MANUAL LITHIUM-ION POLYMER MINI JUMP STARTER (KIT SET) SC POWER SCB22

INSTRUCTION MANUAL LITHIUM-ION POLYMER MINI JUMP STARTER (KIT SET) SC POWER SCB22 INSTRUCTION MANUAL LITHIUM-ION POLYMER MINI JUMP STARTER (KIT SET) Technica Specifications SCB22 Battery Type: Lithium-Ion Poymer Battery Capacity: 2200 mah (12V DC) Crancking Ampere: 220 A Peak Current:

More information

GXL SERIES. DC 2-wire type Micro-size Inductive Proximity Sensor. High performance in micro-size design. Reduced wiring operation. Versatile mounting

GXL SERIES. DC 2-wire type Micro-size Inductive Proximity Sensor. High performance in micro-size design. Reduced wiring operation. Versatile mounting 1 DC -wire Micro-size Inductive Proximity SERIES Reated Information Genera terms and conditions... F- Gossary of terms... P.176~ guide... P.71~ Genera precautions... P.179~ PHOTO PHOTO IGHT FOW PARTICUAR

More information

Linear Slot Diffusers Series

Linear Slot Diffusers Series Linear Sot iffusers 5000 Series Linear Sot iffusers 5000 Series The Series 5000 Linear Sot Ceiing iffuser has been speciay designed to provide both the unobtrusive appearance required for architectura

More information

Precision Ground Plates and Flat Bars. Lifting and Clamping Devices. Ground Precision Components. Elastomer-Bars, -Sheets, -Sections

Precision Ground Plates and Flat Bars. Lifting and Clamping Devices. Ground Precision Components. Elastomer-Bars, -Sheets, -Sections A B C D E F G H J K L Die Sets Precision Ground Pates and Fat Bars Lifting and Camping Devices Shanks, ifter studs, eyebots Camping caws, screws and bots Guide eements Ground Precision Components Springs

More information

ABB Measurement & Analytics. Valve positioners For marine applications

ABB Measurement & Analytics. Valve positioners For marine applications ABB Measurement & Anaytics Vave positioners For marine appications 2 VALVe positioners For marine appications Vave positioners For the marine industry ABB s industry proven EDP300 and TZIDC positioners

More information

Fenix TK65R Flashlight

Fenix TK65R Flashlight BrightGuy.com is an authorized Fenix Distributor Fenix TK65R Fashight 1. Cataput action bet cip 2. Quick-reease button Technica Parameters ANSI/PLATO Genera Mode Fash Mode FL1 Turbo High Med Low Eco Strobe

More information

Components for. Overhead Cranes. Sta dard n. Engineered. Hoists. Endtrucks. Crane Kits. Engineered Material Handling

Components for. Overhead Cranes. Sta dard n. Engineered. Hoists. Endtrucks. Crane Kits. Engineered Material Handling Engineered Materia Handing Components for Overhead Cranes Sta dard n Hoists Engineered Hoists Endtrucks Crane Kits Troey drive consists of singe speed squirre-cage gear motors. Integra disc brakes are

More information

GXL SERIES. DC 2-wire type Micro-size Inductive Proximity Sensor. High performance in micro-size design. Versatile mounting. Reduced wiring operation

GXL SERIES. DC 2-wire type Micro-size Inductive Proximity Sensor. High performance in micro-size design. Versatile mounting. Reduced wiring operation 777 PHOTO PHOTO DC -wire Micro-size Inductive Proximity SERIES Reated Information Genera terms and conditions... F-17 Gossary of terms... P.16~ seection guide... P.77~ Genera precautions... P. Conforming

More information

Flexible Electric Cables for Mining Applications

Flexible Electric Cables for Mining Applications Fexibe Eectric Cabes for Mining Appications Fexibe Eectric Cabes Cataog BU IS 2.3 2000 Fexibe Eectric Cabes for Mining Appications 1 Genera Detais 2 Seection of Cabes 3 Cabe Accessories 4 Tabes/Expanations

More information

Heating Cables. For Industry Tracing

Heating Cables. For Industry Tracing Heating Cables For Industry Tracing FATI-FFHT-X 1/2 FFHT-X Features Energy efficient, automatically varies its power output in response to pipe temperature changes. Easy to install, can be cut to any length

More information

1B20 1B30 1B40. The engineering result of careful market research: Small, light, powerful and universally applicable kw HP.

1B20 1B30 1B40. The engineering result of careful market research: Small, light, powerful and universally applicable kw HP. The engineering resut of carefu market research: Sma, ight, powerfu and universay appicabe Te: 0 85 3 / 39-0 Fax: 3 94 8 http://www.hatz-diese.de emai: marketing@hatz-diese.de.4-7.7 kw.8-0.5 HP 5 / 629

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches Rotary Cam es Series... 2 Hande Assembies... 8 Accessories... 12 Circuit Diagrams, Technica Information & Dimensions (Onine)... 13 Series R-Line Rotary Cam es... 24 Handes and Accessories... 27 Circuit

More information

ANTILOCK BRAKE SYSTEM

ANTILOCK BRAKE SYSTEM SECTION 4F ANTILOCK BRAKE SYSTEM Caution: Disconnect the negative battery cabe before removing or instaing any eectrica unit or when a too or equipment coud easiy come in contact with exposed eectrica

More information

Aluminium Fixed Blade Return Grilles Series

Aluminium Fixed Blade Return Grilles Series Auminium Fixed Bade Return Gries 4900 Series Auminium Fixed Bade Return Gries Modes 5145H and 51FH Return Gries have fixed horizonta bades (parae to width/first specified dim.) spaced on 19mm centres with

More information

c ssupertrak superior cubicle curtain track system

c ssupertrak superior cubicle curtain track system www.cs-france.fr c ssupertrak superior cubice curtain track system innovative design fexibiity of configuration rigid and durabe smooth and quiet giding SUPERTRAK CUBICLE CURTAIN TRACK KEY FEATURES There

More information

User Manual. 12 Volt Battery Charger THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS READ ENTIRE INSTRUCTION BEFORE USE

User Manual. 12 Volt Battery Charger THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS READ ENTIRE INSTRUCTION BEFORE USE User Manua 12 Vot Battery Charger Pus Battery maintainer and Rejuvenator THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS READ ENTIRE INSTRUCTION BEFORE USE Mode No. 60134 / 60138 1 WARNING

More information

TANK - S ELECTRICAL SYSTEM

TANK - S ELECTRICAL SYSTEM TANK - S ELECTRICAL SYSTEM Mode Year 2009 TANK - S ELECTRICAL SYSTEM TABLE OF CONTENTS: PAGE 3 ) PIMARY WIRE COLOR DESIGNATION: Red. Green. Orange. Yeow. Bue. PRIMARY COMPONENTS: Battery. Fuses. Seat Switch.

More information

n Section for connecting rigid or flexible conductors (with Starfix ferrules) Distribution Blocks Four pole Equipped with 4 bars

n Section for connecting rigid or flexible conductors (with Starfix ferrules) Distribution Blocks Four pole Equipped with 4 bars www.kinkmann.com moduar distribution bocks 40 to 0 moduar distribution bocks 40 to 0 048 76 + 048 46 048 77 Technica characteristics (p. 2) Standard distribution Connection with or without Starfix ferrues

More information

Overview. The MicorTIG series at a glance

Overview. The MicorTIG series at a glance www.orch.com.au Overview Lorch, word-eading, new, a in one resonance technoogy that enabes the next generation of portabe machines to operate from mains suppy, sma generators and batteries a deivering

More information

The giant amongst the giants.

The giant amongst the giants. BB9090 PLUS 02 BB9090 PLUS The giant amongst the giants. The argest mode of the New Hoand big baer range is the BB9090 PLUS. Its superior performance both in terms of perfect, firm, we-shaped baes as we

More information

Procyon 1. Product # Type Date Project Name Project Location Prepared By. Construction. Optical System. Product Applications. l l l. l l l.

Procyon 1. Product # Type Date Project Name Project Location Prepared By. Construction. Optical System. Product Applications. l l l. l l l. Product # Type Date Project Name Project Location Prepared By Construction Housing is ow copper die-cast auminum, heavy duty, structuray rigid and vibranty dissipating heat for onger umen maintenance ife-hours.

More information

120/240 Volts 3 Watt Floor Heating Cable System

120/240 Volts 3 Watt Floor Heating Cable System WA-3CWC 120/240 Volts 3 Watt Floor Heating Cable System Warm Cable floor heating system combines the highest comfort levels with maximum energy efficiency. It is a proven technology that is safe, reliable

More information

Model TWS. Swirl Diffusers

Model TWS. Swirl Diffusers Mode TWS Swir Diffusers Mode TWS Advanced Air s new range of high performance TWS ceiing swir diffusers have been designed to deiver the high air change rates required to meet the demand of high oads.

More information

Product Catalogue. Worldwide Specialists in Electric Heat Tracing. HTS THERMTRACE HTS THERMTRACE HTS T

Product Catalogue. Worldwide Specialists in Electric Heat Tracing.  HTS THERMTRACE HTS THERMTRACE HTS T Product Catalogue HTS THERMTRACE HTS THERMTRACE HTS T HTS THERMTRACE HTS THERMTRACE HTS T HTS THERMTRACE HTS THERMTRACE www.hts-global.com is an international operating manufacturer of electric heating

More information

EMEX Central Power Supply Systems Catalogue

EMEX Central Power Supply Systems Catalogue EMEX Centra Power Suppy Systems Cataogue The Emergi-Lite portfoio from Thomas & Betts deivers a highy versatie choice of emergency ighting and fire detection products and systems for a wide range of appications.

More information

Intelligent Softstarter Controllers

Intelligent Softstarter Controllers Inteigent Softstarter Controers Genera escription... 2 Custom Softstarter Panes... 4 Series PCS Controers... 6 Seection Guide... 8 Accessories... 19 Repacement Parts... 21 Technica Information & imensions

More information

USER INSTRUCTIONS USER INSTRUCTIONS. Innovative Car Alarm. Thatcham M.I.R.R.C. Evaluation No: TC2-1065/0199

USER INSTRUCTIONS USER INSTRUCTIONS. Innovative Car Alarm. Thatcham M.I.R.R.C. Evaluation No: TC2-1065/0199 USER INSTRUCTIONS USER INSTRUCTIONS Innovative Car Aarm Thatcham M.I.R.R.C. Evauation No: TC2-1065/0199 IMPORTANT WARNING The Cobra 7928/26/HF Aarm Immobiiser is a Category 1 MIRRC Thatcham isted security

More information

TK35UE 2018 Flashlight

TK35UE 2018 Flashlight TK35UE 2018 Fashight Technica Parameters ANSI/PLATO FL1 Genera Mode Fash Mode Turbo High Med Low Eco Strobe SOS Output Tactica Mode Outdoor Mode 3200 2000 1000 350 100 20 3200 100 1h 30min 2h 3h 40min

More information

Rule No. 16 SERVICE CONNECTIONS, METERS, AND CUSTOMER S FACILITIES

Rule No. 16 SERVICE CONNECTIONS, METERS, AND CUSTOMER S FACILITIES SOUTHERN CALIFORNIA WATER COMPANY Revised Ca. P.U.C. Sheet No. 3450-W SAN DIMAS, CALIFORNIA 91773-9016 Canceing Revised Ca. P.U.C. Sheet No. 3293-W Page 1 of 7 A. Genera 1. Utiity s Responsibiity a. (1)

More information

CARGO CONNECT COMPACT

CARGO CONNECT COMPACT » Connected to you CARGO CONNECT COMPACT Configure on demand, meet changing needs UNITED KINGDOM 02 03 CARGO CONNECT COMPACT Compact, adaptabe transport traier. Adaptabe to meet a vast array of different

More information

ASSEMBLY AND INSTALLATION

ASSEMBLY AND INSTALLATION ASSEMBY AND INSTAATION STRAIGT AND EVE GUARDRAIING (using Tpes 10, 15, 20, 21, 25 & 26) Where: = distance between centres of uprights I = ength of horizonta tube = distance from ground to centre ine of

More information

CruzPro UWSD-10. Ultrasonic 3D Wind Speed/Direction Sensor with NMEA 0183/RS422 Output. Other CruzPro Products

CruzPro UWSD-10. Ultrasonic 3D Wind Speed/Direction Sensor with NMEA 0183/RS422 Output. Other CruzPro Products emai: info@cruzpro.com website: www.cruzpro.com Other CruzPro Products Wind Speed/Direction Dispay Depthsounders/w Kee Offset, Deep/Shaow/Anchor Drag Aarms PC Based DSP Fishfinder for Windows98, XP, 2000,

More information

N1VS VARIABLE SPEED AIR HANDLERS

N1VS VARIABLE SPEED AIR HANDLERS (0500) TECHNICAL SPECIFICATIONS VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING AND HEAT PUMP 600-2000 CFM BLOWERS 2-5 TON COILS OPTIONAL1 & 3 Ø ELECTRIC HEATERS DESCRIPTION These variabe

More information

GEAR MOTORS. Displacement from 2 to 15 ccm Pressure up to 280 bar Speed from 500 to 4000 RPM

GEAR MOTORS. Displacement from 2 to 15 ccm Pressure up to 280 bar Speed from 500 to 4000 RPM Dispacement from 2 to 15 ccm Pressure up to 280 bar Speed from 500 to 4000 PM GEA MOTOS JM Gear Motor Cataogue JM TABE OF CONTENTS DESCIPTION......................................................................................................................

More information

Piston pumps for eff icient wellpoint dewatering

Piston pumps for eff icient wellpoint dewatering Piston pumps for eff icient wepoint dewatering PT series P u m p s f o r r e s u t s Innovative eaders for the past 60 years BBA Pumps BV woudn t be a Dutch company if it didn t know how to dea with water!

More information

Mechanical Level Switches

Mechanical Level Switches Mechanica Leve Switches SOR mechanica eve switches are rugged, industria products specificay designed for versatiity of appication. This cataog contains appication and ordering data for foat and dispaceroperated

More information

A Product of Hard Work SELECTOR GRABS

A Product of Hard Work SELECTOR GRABS A Product of Hard Work SELECTOR GRABS ATTACHMENTS SELECTOR GRABS The perfect partner for your machine Simpe heavy duty design for maximum durabiity and reiabiity Buit in safety features to protect the

More information

GStype/HGStype/WGStype

GStype/HGStype/WGStype Tooing News No.E473 Achieving Stabe And Long Too Life With Exceent Chip Evacuation Super MutiDri GStype/HGStype/WGStype 2009-015 series series New J fute Design Achieves Exceent Chip Contro And Stabe Driing

More information

EP Series WPS150S. Generator Set Specification. Super Quiet, Superior Life! Page of 5

EP Series WPS150S. Generator Set Specification. Super Quiet, Superior Life! Page of 5 EP Series Generator Set Specification Super Quiet, Superior Life! Page - 1 - of 5 3-Phase, 50Hz@1500RPM Prime Power Standby Power Votage kw kva Amps 380 120 150 227.9 400 120 150 216.5 415 120 150 208.7

More information

Healthcare Sector Products

Healthcare Sector Products Heathcare Sector Products MK Eectric is the UK s premium eectrica accessories brand and for over 90 years has been offering a comprehensive range of soutions for specifiers and instaers of eectrica products

More information

--... Need a prototype tomorrow? Experts in customization, innovative design and engineering

--... Need a prototype tomorrow? Experts in customization, innovative design and engineering . Hay!J.~!!., kerk " Experts in customization, innovative design and engineering Haydon Kerk Motion Soutions has the e

More information

Filter Return Grilles. 51F Series Aluminium

Filter Return Grilles. 51F Series Aluminium Fiter Return Gries 51F Series uminium Fiter Return Gries 51F Series uminium The dvanced ir Mode Series 51F Fiter Return Gries are a convenient and economica means of fitering primary return air ocay. They

More information

SELECT your. distribution SySTEm GLOBAL SPECIALIST FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SELECT your. distribution SySTEm GLOBAL SPECIALIST FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES SELECT your distribution SySTEm GLOBAL SPECIALIST FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Distribution is an essentia function for the eectrica panes, as we as for contro and circuit protection.

More information

SP Stationary concrete pump. Concrete output max. 113 m³/h Concrete output max. 162 bar. 18,300-19,400 lb

SP Stationary concrete pump. Concrete output max. 113 m³/h Concrete output max. 162 bar. 18,300-19,400 lb SP 38 Stationary pump Concrete output max. 113 m³/h Concrete output max. bar Concrete output - 24 kw Machine weight 8,3-8,8 kg 18,3-19,4 b The SP 38 from SCHWING Performance and reiabiity SP 38 Stationary

More information

Prestolok. Spark resistant push-in fittings for fluids. Catalogue /UK

Prestolok. Spark resistant push-in fittings for fluids. Catalogue /UK Spark resistant push-in fittings for fuids Cataogue 352-/UK Cataogue 352-/UK Index Straight connectors Mae - BSPT Mae - Metric Mae - BSPT Mae - NPTF F23PB - p. C F2PB - p. C F3PB - p. C FPB - p. C Mae

More information

HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines

HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines HOTLINE Insulated Tubing for Steam Supply & Condensate Returns Lines PVC jacket - Deg C (optionally PUR material) Glass fibre thermal insulation Process tube(s) Heat reflective tape Electrical heating

More information

GEAR PUMPS. Displacement from 7 to 51 ccm Pressure up to 260 bar QHD0. Speed from 350 to 3400 RPM

GEAR PUMPS. Displacement from 7 to 51 ccm Pressure up to 260 bar QHD0. Speed from 350 to 3400 RPM GEA PUMPS Dispacement from 7 to 51 ccm Pressure up to 260 bar QHD0 Speed from 350 to 3400 PM Gear Pump Cataogue QHD0 TABE OF CONTENTS DESCIPTION......................................................................................................................

More information

Displacement from 10 to 100 ccm Pressure up to 300 bar Speed from 300 to 3200 RPM GEAR PUMPS QHD1

Displacement from 10 to 100 ccm Pressure up to 300 bar Speed from 300 to 3200 RPM GEAR PUMPS QHD1 Dispacement from 10 to 100 ccm Pressure up to 300 bar Speed from 300 to 3200 PM GEA PUMPS QHD1 Gear Pump Cataogue QHD1 TABE OF CONTENTS DESCIPTION......................................................................................................................

More information

solenoid dosing pumps

solenoid dosing pumps teknaevo soenoid dosing pumps innovation > technoogy > future The evoution of soenoid dosing pumps Cever Just Modes, Just PVDF, A functions in one pump modes that cover 1 to 60 t/h with an output pressure

More information

Connected to you 2019

Connected to you 2019 2019» Connected to you Fu body ength viny (white traiers ony). Larger main side doors on both sides. 02 03 Standard. Not avaiabe. NCO = no cost option. Change to front nose mouding Now a thin nose section

More information

MOUNTING BRACKET SET. 2RT 2RT = Type-II Rectangle 3AS = Type-III Asymmetrical 5SQ = Type-V Square 4CBPB = Couter/Pro Beam L I G H T I N G

MOUNTING BRACKET SET. 2RT 2RT = Type-II Rectangle 3AS = Type-III Asymmetrical 5SQ = Type-V Square 4CBPB = Couter/Pro Beam L I G H T I N G Product # Type Date Project Name Tunne LED Project Location Prepared By Housing Encosure Extruded, ow copper, corrosion resistant auminum aoy 6063-T5 and cear anodized, Cass 1, Type II per specification

More information

Flat fan nozzles. Nozzle characteristics

Flat fan nozzles. Nozzle characteristics Fat fan nozzes Bet ceaning Coating Steam ceaning Degreasing High pressure ceaning Grave washing Cooing Surface treatment Phosphating Rain curtains Foam contro Foam spraying Lubrication Fiter ceaning ceaning

More information

Operating Instructions KSR-TF 611 with contactless electronic switch

Operating Instructions KSR-TF 611 with contactless electronic switch Operating Instructions KSR-TF 6 with contactess eectronic switch Contents Contents About this document. Function............................. 4.2 Target group.......................... 4.3 Symboism used.......................

More information

For use anywhere. Many convenient features

For use anywhere. Many convenient features Controers IN-rai mounted softstarters up to 85A. Larger softstarter frame sizes up to 480A (400HP @480V) Sprecher + Schuh IN-rai mounted Controers can be direct connected to CA7 contactors to provide isoation

More information

PRECISION PUMP APPLICATOR

PRECISION PUMP APPLICATOR User s Manua nstaation & Operating nstructions PRECSON PUMP APPLCATOR For Box, Junior, and Custom Appicators For questions and/or product support contact the TW ROCOL North America Customer Service Department

More information

Industry. SNR, your guide to linear modules

Industry. SNR, your guide to linear modules Industry SNR, your guide to inear modues SNR A bearing manufacturer known across the word For amost a century SNR has been focusing on the deveopment, design and manufacture of bearings. Today SNR has

More information

XTS-W+ Bearing Condition Monitor

XTS-W+ Bearing Condition Monitor XTS-W+ Bearing Condition Monitor efficient, cost-effective, reevant soutions AMOT has been a pioneering manufacturer of quaity components for marine rotating machinery since 1948 and innovation is something

More information

Displacement from 43 to 150 ccm Pressure up to 280 bar Speed from 250 to 3200 RPM GEAR PUMPS QHD2

Displacement from 43 to 150 ccm Pressure up to 280 bar Speed from 250 to 3200 RPM GEAR PUMPS QHD2 Dispacement from 43 to 150 ccm Pressure up to 280 bar Speed from 250 to 3200 PM GEA PUMPS QHD2 Gear Pump Cataogue QHD2 TABE OF CONTENTS BASIC DESCIPTION.............................................................................................................

More information

Displacement from 9 to 31 ccm Pressure up to 280 bar Speed from 500 to 3000 RPM GEAR PUMPS T3S

Displacement from 9 to 31 ccm Pressure up to 280 bar Speed from 500 to 3000 RPM GEAR PUMPS T3S Dispacement from 9 to 31 ccm Pressure up to 280 bar Speed from 500 to 3000 PM GEA PUMPS T3S Gear Pump Cataogue T3S TABE OF CONTENTS DESCIPTION......................................................................................................................

More information

Connect - Contact - Control. Charging Connectors LV Series A 84.en

Connect - Contact - Control. Charging Connectors LV Series A 84.en Connect - Contact - Contro Charging Connectors LV Series 34.5 63 83 94 A 84.en LV Series charging connectors Competence, innovation and decades of experience Our new LV Series charging connectors represent

More information

Installation Systems

Installation Systems Instaation Systems Roca Instaation Systems Introduction to Roca Instaation Systems Instaation Systems are a fundamenta part of the bathroom. Roca Instaation Systems offer an affordabe soution when a practica,

More information

Air nozzles. Air curtains Blowing off and out Cleaning Cooling Drying Reheating Transporting and many others...

Air nozzles. Air curtains Blowing off and out Cleaning Cooling Drying Reheating Transporting and many others... Air nozzes Air curtains Bowing off and out Ceaning Cooing Drying Reheating Transporting and many others Air nozzes As a rue, any fat fan or soid stream nozze can be operated with air instead of iquid However,

More information

Operating instructions CI24RP.. CI30RP..

Operating instructions CI24RP.. CI30RP.. Operating instructions en CI24RP.. CI30RP.. Tabe of Contents Congratuations.................................................................................. 3 Safety and warning information......................................................................

More information

Installation Systems Roca_Installation_Systems_v24.indd 1 30/03/ :57

Installation Systems Roca_Installation_Systems_v24.indd 1 30/03/ :57 Instaation Systems Roca Instaation Systems Introduction to Roca Instaation Systems Instaation Systems are a fundamenta part of the bathroom. Roca Instaation Systems offer an affordabe soution when a practica,

More information

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework FREEZSTOP MICRO SYSTEM Freeze Protection of Pipework Prevent Burst or Blocked Pipes The Problem Thermal insulation alone will not prevent freezing of pipes. For example, a 3/4 pipe having 25mm thick insulation

More information

EH Range Technical Data

EH Range Technical Data EH Range Technica Data Eectro-hydrauic Vave Actuators Redefining Fow Contro EH Range Technica Data INTRODUCTION The Rotork EH Range of sef-contained, eectro-hydrauic actuator incudes an integrated contro

More information

130 HP MF TELEHANDLER MF TH 7038

130 HP MF TELEHANDLER MF TH 7038 130 HP MF TELEHANDLER MF TH 7038 Raising the bar Massey Ferguson s TH 7038 teehander is now upgraded with a number of new features to further improve productivity, ease of use and efficiency. Power and

More information

Curriculum Training TF S Automatic Transmission

Curriculum Training TF S Automatic Transmission Technica Service Training Goba Fundamentas Curricuum Training TF0004S Automatic Transmission Student Information FCS-300-REF CG7970/S en /00 Copyright 00 Ford Motor Company Introduction Preface Goba fundamentas

More information

Intelligent Softstarter Controllers

Intelligent Softstarter Controllers Inteigent Softstarter Controers Genera escription... 2 Series PCS Controers - escription... 4 Seection Guide... 6 Accessories... 17 Repacement Parts... 19 Technica Information... 20 Wiring iagrams... 24

More information

EC Series GMS200C. Generator Set Specification. Your Partner for Power. Page of 5

EC Series GMS200C. Generator Set Specification. Your Partner for Power. Page of 5 EC Series Generator Set Specification Your Partner for Power Page - 1 - of 5 3-Phase, 50Hz@1500RPM Prime Power Standby Power Votage kw kva Amps 380 160 200 303.9 400 160 200 288.7 415 160 200 278.2 440

More information

S.B. 469 for information on GM applications). Both styles are shown in Figure 1. Figure 1

S.B. 469 for information on GM applications). Both styles are shown in Figure 1. Figure 1 NO: 4263132 SERVICE BULLETIN DATE: January X,1993 Supersedes: S.B. 426R dated 11/7/89 SUBJECT: ZERO-CLEARAN CE GOVERNOR WEIGHT RETAINER ASSEMBLIES In June 1988, Stanadyne introduced a zero-cearance Eastomer

More information

TOYOTA CAPS TONNEAUS THE RIGHT FIT. Style. Security. Selection.

TOYOTA CAPS TONNEAUS THE RIGHT FIT. Style. Security. Selection. CAPS TONNEAUS TOYOTA THE RIGHT FIT Stye. Security. Seection. STYLING THAT S AHEAD OF THE CURVE! ROYAL The Roya is custom-styed to match your specific truck mode. SUV inspired side windows have twist-out

More information

PROTECTRON MACHINED CONTACT CONNECTORS

PROTECTRON MACHINED CONTACT CONNECTORS PROTECTRON MACHINED CONTACT CONNECTORS PROTECTRON INTRODUCTION INNER CLIP The inner cip consists of 4 Leaf Springs, stamped and rounded to take strip/round mae contacts at the bottom edge, faciitating

More information

Optional Modes of Operation Pump Control Brake Control - Smart Motor Brake, Accu-stop and Slow Speed with Braking

Optional Modes of Operation Pump Control Brake Control - Smart Motor Brake, Accu-stop and Slow Speed with Braking Controers The Inteigent Controer with extensive starting and stopping configurations up to 1000HP (3-wire), 1400HP (6-wire) The Softstarter Controer provides inteigence, unmatched performance, fexibiity,

More information

Blanking tools for the automotive industry

Blanking tools for the automotive industry anking toos for the automotive industry 1736 006 3 rt.-nr..400.03.0706.01000 07/006 17363 00 1 anking toos for the automotive industry Tabe of contents age age FIRO Tradition and Technoogy 6 7 0. 1.. 3.

More information

Great to come home to!

Great to come home to! Great to come home to! Inteigent design, dependabe quaity... every time 10dB aarm! No compromise on Quaity We a associate quaity with craftsmanship and there are three things behind great work; the finest

More information

GEAR PUMPS. Displacement from 10 to 36 ccm Pressure up to 300 bar GHD0. Speed from 350 to 3400 RPM

GEAR PUMPS. Displacement from 10 to 36 ccm Pressure up to 300 bar GHD0. Speed from 350 to 3400 RPM GEA PUMPS Dispacement from 10 to 36 ccm Pressure up to 300 bar GHD0 Speed from 350 to 3400 PM Gear Pump Cataogue GHD0 TABE OF CONTENTS DESCIPTION......................................................................................................................

More information

ABOVE GROUND TANKS 66 WATER DIVISION ROTOTEC

ABOVE GROUND TANKS 66 WATER DIVISION ROTOTEC OVE GROUND TNKS 66 WTER DIVISION ROTOTEC WTER DIVISION ROTOTEC 67 VERTICLE From 50 to 10000 itres Instaation Paced directy on a fat supporting surface vaiabe coours: standard on request Ø Cover Inet Outet

More information

/1505-I-20 TOO L HO L DERS 2015 GM 300

/1505-I-20 TOO L HO L DERS 2015 GM 300 TO O L H O L D ERS A N D C L A M PI N G D E V I C ES 114 996/1505-I-20 ED I T I O N 2015 TOO L HO L DERS 2015 GM 300 high camping ce PERFECT CONCENTRICITY MAXIMUM OPERATIONAL SAFETY OPTIMAL COOLANT DELIVERY

More information

Operating instructions Maintenance instructions

Operating instructions Maintenance instructions Operating instructions Maintenance instructions Origina operating instructions S/N 101 692 26 1434 > / S/N 101 692 35... Reversibe Vibrating Pate Cataogue No. 008 067 61 12/2012 Foreword 1 Foreword BOMAG

More information

MOTO 2T Cod DESCRIPTION CHARACTERISTICS ADVICE ON USE TECHNICAL DATA

MOTO 2T Cod DESCRIPTION CHARACTERISTICS ADVICE ON USE TECHNICAL DATA MOTO 2T Cod. 1051 Lubricating base oi, suitabe for a vehices equipped with 2 stroke engines. Suitabe with any kind of mix system (automatic or premix) powered by either eaded or uneaded petro. It contains

More information

VDC Series High-Pressure Type Variable Volume Vane Pump

VDC Series High-Pressure Type Variable Volume Vane Pump V SRS PRSSUR TYP VARA VU VA PUP V Series igh-pressure Type Variabe Voume Vane Pump eatures q ighy efficient and stabe high-pressure operation nnovative pressure contro and pressure baance mechanisms combine

More information

30 Electric ding. IMPORTANT: Read and save these instructions. ALL RANGES CAN TIP INJURY TO PERSONS COULD RESULT SEE INSTALLATION INSTRUCTIONS

30 Electric ding. IMPORTANT: Read and save these instructions. ALL RANGES CAN TIP INJURY TO PERSONS COULD RESULT SEE INSTALLATION INSTRUCTIONS Part No. 9752387 ALL RANGES CAN TIP INJURY TO PERSONS COULD RESULT INSTALL ANTI-TIP DEVICE PACKED WITH RANGE SEE INSTALLATION INSTRUCTIONS 30 Eectric ding IMPORTANT: Read and save these instructions. IMPORTANT:

More information

Extremely uniform liquid distribution Wide flow rate range Large number of available spray angles

Extremely uniform liquid distribution Wide flow rate range Large number of available spray angles Absorption Chemica process engineering Chorine precipitation Ceaning Cooing esuperheating ust contro Fire protection Foam contro as treatment Spraying onto mats in air washers Spraying over packings Surface

More information

S I G N E X T R U S I O N S & S Y S T E M S. Kit Includes: LED s. Power Supply. Clear Plastic (Not Included) 1/2 Opening. Cap Screw Part #5940

S I G N E X T R U S I O N S & S Y S T E M S. Kit Includes: LED s. Power Supply. Clear Plastic (Not Included) 1/2 Opening. Cap Screw Part #5940 3032 Waker Ridge Dr. NW Grand Rapids, MI To Free: (877) 784-0405 Fax: (1) 784-0411 Wa Mount Tension Frame (Mi Finish) Cover Screw Part #5215 1 4-1/8 1-1/ Fexibe Face (Not Incuded) Mounting Hardware (Not

More information

External Louvres Series

External Louvres Series Externa Louvres 1600 Series Genera Product Overview Externa Louvres Advanced Air Externa Louvres feature an architecturay appeaing straight bade design with smooth, cean ines that visuay compiment any

More information