Positive displacement flowmeter for continuous flow measurement
|
|
- Maud Booker
- 5 years ago
- Views:
Transcription
1 8070 Positive displacement flowmeter for continuous flow measurement High accuracy Medium with high viscosity Mounting and dismounting of the electronics by a quarter-turn Connection to Bürkert devices in remote versions Type 8070 can be combined with... Type 8025 Type 8025 Konti-Dos Type 8611 Type 2712 (8630) PLC Flow transmitter remote version Batch control system econtrol Universal controller Continuous TopControl system The positive displacement flowmeter for continuous flow measurement is especially designed for use in highly viscous fluid like glue, honey or oil. It is made up of a compact sensor fitting (S070) with integrated oval rotor and an electronic module (SE30) with pulse signal (Hall transducer), quickly and easily connected together by a Quarter-Turn. The Bürkert designed fitting system ensures simple installation of the devices into all pipes from DN15 to DN100. The flowmeter produces frequency signal (pulse), proportional to the flow rate, which can easily be transmitted and processed by: - a Bürkert remote transmitter (Type 8025/ ) - a batch control system 8025 Konti-Dos - a PLC Technical data General data Compatibility with sensor fittings S070 (see corresponding data sheet) Materials Housing, cover PC Cable plug PA Wetted parts materials Sensor fitting Aluminium, stainless steel (316F/1.4401) Rotor PPS, aluminium, stainless steel (316F/1.4401) Shaft / Seal Stainless steel / FKM or FEP/PTFE encapsulated Electrical connection Cable plug EN Connection cable max. 1.5 mm 2 cross section; max. 50 m length, shielded (for pulse sensor version) Complete device data (sensor fitting + electronic module) Pipe diameter DN15 to DN100 Measuring range Viscosity > 5 cps Viscosity < 5 cps Medium temperature max. Aluminium body Stainless steel body Fluid pressure max. DN15 DN25 DN40 / DN50 DN80 DN100 Viscosity Accuracy Repeatability 1) or in accordance to the value of the used flanges 1 to 1200 l/min (0.26 to 320 gpm) 3 to 616 l/min (0.78 to 320 gpm) 80 C (176 F) 100 C (212 F) 55 bar ( PSI) (threaded process connection) 55 bar ( PSI) 1) 18 bar ( PSI) 12 bar ( PSI) 10 bar (145.1 PSI) 1000 cps. max (higher on request) ±0.5% of Reading ±0.03% of Reading p. 1/4
2 8070 Electrical data Operating voltage Pulse version Pulse Low Power version Current consumption with sensor Pulse version Pulse Low Power version Output: Frequency Pulse version Pulse Low Power version Reversed polarity of DC Environment Ambient temperature Relative humidity Standards and approvals Protection class Standard EMC Pressure (Sensor fitting S070, DN15 to DN100, in aluminium or stainless steel) V DC, filtered and regulated V DC filtered and regulated (via Bürkert transmitter) < 30 ma < 0.8 ma Transistor NPN/PNP, open collector, max. 100 ma, frequency: Hz; duty cycle 50% Transistor NPN, open collector, max. 10 ma, frequency: Hz; duty cycle 50% Protected 0 to +60 C (32 to 140 F) (operating and storage) 80%, without condensation IP65 with connector plugged-in and tightened EN , Complying with article 3 of Chap. 3 from 97/23/CE directive.* (without CE mark) * For the 97/23/CE pressure directive, the device can only be used under following conditions (dependent on max. pressure, pipe diameter and fluid). Type of fluid Conditions Fluid group 1, chap. 1.3.a Forbidden Fluid group 2, chap. 1.3.a Fluid group 1, chap. 1.3.b Fluid group 2, chap. 1.3.b DN 32 or DN > 32 and PN*DN 1000 PN*DN 2000 DN 200 Design and principle of operation The flowmeter 8070 is built up with an electronic module SE30 associated to a sensor fitting S070 with integrated measurement oval rotor. This connection is made by means of a Quarter-Turn. Quarter-Turn Technology SE In a 3-wire system (transistor output), the signal can be displayed or processed directly. The output signal is provided via cable plug according to EN S070 When liquid flows through the pipe, the rotors turn. This rotation produces a measuring signal in the transducer. The frequency and amplitude are proportional to the flow. A conversion coefficient (K factor, available in the instruction manual of the sensor fitting S070), specific to each pipe (size and material) enables the conversion of this frequency into a flow rate. Two electronic module versions with frequency output are available: - with one pulse output (either NPN or PNP transistor output). An external power supply of V DC is required. It is designed for connection to any system with open collector NPN or PNP frequency input. - with one pulse Low Power output (NPN transistor output). An external power supply of V DC is required. Can only be connected to separate versions of flow transmitters Type 8025/8032, to ma module Type 8023 or a universal controller econtrol Type Installation The sensor fitting can be installed in any orientation as long as the rotor shafts are always in a horizontal plane (see figures to the right) and the flow of the fluid is in the direction of the arrow marked on the body. Correct The pipe must be filled with liquid and free from air bubbles. Avoid air purge of the system which would cause damages and to prevent damage from dirt or foreign matter, we strongly recommend the installation of a 250 m strainer as close as possible to the inlet side of the meter. Correct Incorrect p. 2/4
3 8070 Dimensions Orifice H DN15 DN25 DN40 DN50 Threaded connection DN80 DN25 DN40 DN50 DN80 Flanged connection DN100 Ordering chart for flowmeter Type 8070 A flowmeter Type 8070 consists of: - an electronic module with pulse signal Type SE30 - an INLINE sensor fitting S070 (DN15 - DN100 - Refer to corresponding data sheet) Electronic module Type SE30 - for sensor fitting Type S070 (to be ordered separately) Description Operating voltage Output Electrical connection Pulse flowmeter version (pluggable to PLC) Pulse Low Power flowmeter version (only pluggable to Type 8025, 8032, 8023 or 8611) V DC Frequency with pulse PNP or NPN, open collector from associated transmitter Frequency with pulse NPN, open collector Cable plug EN Cable plug EN p. 3/4
4 8070 Ordering chart for accessories for flowmeter Type 8070 (to be ordered separately) Version Specifications Operating voltage Outputs Relays Electrical connection Compatible remote transmitter Panelmounted Flow controller Type V DC NPN and NPN - Terminal strip Universal flow transmitter Type V DC ma (3- - Terminal strip , 2 totalisators wire) + pulse 2 Terminal strip Batch controller Type 8025, V DC - 2 Terminal strip totalisators and 1 flowrate Wallmounted Flow controller Type V DC NPN and NPN Free positionable 5-pin M12 male and 4-pin M12 female connectors Universal flow transmitter Type 8025, 2 totalisators Batch controller Type 8025, 2 totalisators and 1 flowrate V DC ma ( cable glands wire) + pulse 2 3 cable glands V AC ma ( cable glands wire) + pulse 2 3 cable glands V DC cable glands V AC cable glands Specifications 4-pin M12 female connector moulded on cable (2 m., shielded) pin M12 female connector with plastic threaded locking ring pin M12 female connector moulded on cable (2 m., shielded) pin M12 female connector moulded on cable (2 m., shielded) Interconnection possibilities with the flowmeter Type 8070 Type Remote flow transmitter/ batch controller PLC Type Remote flowmeter Type Low Power Hall flowmeter with pulse signal NPN output Type Hall flowmeter with pulse signal NPN /PNP output To find your nearest Bürkert office, click on the orange box In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 1209/5_EU-en_ p. 4/4
5 S070 Positive displacement sensor fitting for continuous flow measurement DN15 to DN100 INLINE Quarter-Turn technology Electronics available for indication, monitoring, transmitting, On/Off control and batch control Type S070 can be combined for... Type 8070 Type 8072 Type 8075 Type 8076 Positive displacement flowmeter Positive displacement flowmeter Positive displacement flowmeter Positive displacement flowmeter This positive displacement sensor fitting is specially designed for flow measurement and/or batch control of highly viscous fluids like glue, honey or oil. This measuring element must be associated to an electronic module SE30, SE32, SE35, SE36 with hall sensor principle only, quickly and easily connected together by a Quarter-Turn. The design of this fitting is based on the oval rotor principle. This has proven to be a reliable and highly accurate volumetric method of measuring flow. Exceptional repeatability and high accuracy over a wide range of viscosities and flowrates are features of that design. The low pressure drop and high pressure rating make it suitable for both gravity and pump (in-line) applications. General data Compatibility Wetted parts materials Body Rotor Shaft Seal Environment Ambient temperature With electronic SE30, SE32, SE35, SE36 with Hall sensor principle (see separate data sheet) Aluminium, stainless steel (316F) PPS, aluminium, stainless steel (316F) Stainless steel (316F) FKM or FEP/PTFE encapsulated 0 to 60 C (32 to 140 F) (operation and storage) Standards, directives and approvals Protection class IP66 (NEMA 6) Directives Pressure Complying with article 3 of 3 from 97/23/CE directive*. (without CE mark) * For the 97/23/CE pressure directive, the device can only be used under following conditions (dependent on max. pressure, pipe diameter and fluid). Type of fluid Fluid group 1, 1.3.a Fluid group 2, 1.3.a Fluid group 1, 1.3.b Fluid group 2, 1.3.b Conditions Forbidden DN 32, or DN > 32 and PN*DN 1000 PN*DN 2000 DN 200 Complete device data Pipe diameter Thread connection Flange connection Measuring range Viscosity > 5 cps Viscosity < 5 cps Medium temperature max. Medium pressure max. DN15 DN25 DN40/DN50 DN80 DN100 Viscosity Max. particle size Accuracy Repeatibility 1) or in accordance to the value of the used flanges DN15 to DN100 ½ ; 1 ; 1½ ; 2 ; 3 (G or NPT) 25; 40; 50; 80 or 100 mm DIN PN16 flange 1 ; 1½; 2 ; 3 or 4 ANSI 150LB flange 2 to 1200 l/min (0.26 to 320 gpm) 3 to 616 l/min (0.78 to 160 gpm) Aluminium body: 80 C (176 F) Stainless steel body: 120 C (248 F) 55 bar ( PSI) (threaded process connection) 55 bar ( PSI) 1) 18 bar ( PSI) 12 bar ( PSI) 10 bar (145.1 PSI) 1000 cps. max. (higher on request) 250 m - To prevent damage from dirt or foreign matter, we strongly recommend the installation of a 250 m strainer as close as possible to the inlet side of the meter. ±0.5% of Reading ±0.03% of Reading p. 1/4
6 S070 Installation and operation The sensor fitting can be installed in any orientation as long as the rotor shafts are always in a horizontal plane (see figures to the right) and the flow of the fluid is in the direction of the arrow marked on the body. Correct The pipe must be filled with liquid and free from air bubbles. Avoid air purge of the system which would cause damages and to prevent damage from dirt or foreign matter, we strongly recommend the installation of a 250 m strainer as close as possible to the inlet side of the meter. Correct Incorrect When fluid passes through the fitting, rotors turn. This rotation produces a measuring frequency in the associated hall sensor, which is proportional to the flow. Dimensions [mm] Threaded connection Orifice DN A B C D E Stainless steel Aluminium Flanged connection Orifice DN A B B C D E F G H J K L Stainless Steel Al. DIN ANSI DIN ANSI p. 2/4
7 S070 Ordering chart for sensor fitting Type S070 Orifice DN Process connection Flow Range > 5 cps < 5 cps 15 G ½ 2-30 l/min 3-25 l/min Aluminium PPS FKM Body material Rotor material Stainless steel Stainless steel FEP/PTFE NPT ½ 2-30 l/min 3-25 l/min Aluminium PPS FKM Stainless steel Stainless steel FEP/PTFE G l/min l/min Aluminium PPS FKM Stainless steel Stainless steel FEP/PTFE NPT l/min l/min Aluminium PPS FKM Stainless steel Stainless steel FEP/PTFE mm DIN PN16 flange l/min l/min Aluminium PPS FKM Stainless steel Stainless steel FEP/PTFE ANSI 150 LB flange l/min l/min Aluminium PPS FKM Stainless steel Stainless steel FEP/PTFE G 1½ l/min l/min Aluminium PPS FKM Stainless steel Stainless steel FEP/PTFE NPT 1½ l/min l/min Aluminium PPS FKM Stainless steel Stainless steel FEP/PTFE mm DIN PN16 flange l/min l/min Aluminium PPS FKM Stainless steel Stainless steel FEP/PTFE /2 ANSI 150 LB flange l/min l/min Aluminium PPS FKM Stainless steel Stainless steel FEP/PTFE G l/min l/min Aluminium PPS FKM NPT l/min l/min Aluminium PPS FKM mm DIN PN16 flange l/min l/min Aluminium PPS FKM Stainless steel Stainless steel FEP/PTFE ANSI 150 LB flange l/min l/min Aluminium PPS FKM Stainless steel Stainless steel FEP/PTFE G l/min l/min Aluminium Aluminium FKM NPT l/min l/min Aluminium Aluminium FKM mm DIN PN16 flange l/min l/min Aluminium Aluminium FKM ANSI 150 LB flange l/min l/min Aluminium Aluminium FKM mm DIN PN16 flange l/min --- Aluminium Aluminium FKM ANSI 150 LB flange l/min --- Aluminium Aluminium FKM Seal Ordering chart for spare parts for sensor fitting S070 Description Orifice Size [mm] [inch] Materials Rotor DN15 ½ PPS Stainless steel DN25 1 PPS Stainless steel DN40 1 ½ PPS Stainless steel DN50 2 PPS Stainless steel Description Orifice Size [mm] [inch] Materials O-ring DN15 ½ FEP/PTFE FKM DN25 1 FEP/PTFE FKM DN40 1 ½ FEP/PTFE FKM DN50 2 FEP/PTFE FKM p. 3/4
8 S070 Interconnection possibilities with other Bürkert products Transmitter/Controller remote version Compact transmitter Type SE32* Flow switch/ transmitter Type 8025 Flow transmitter/ batch controller Type SE35* Flow transmitter/ batch controller Type SE36 Flow transmitter Type 8032 Flow switch/transmitter Intrinsic safety barrier Type SE30* Flow transmitter Type SE30 Ex - Flow transmitter Fitting with oval rotor Type S070 INLINE sensor fitting * Use only version with Hall transducer To find your nearest Bürkert office, click on the orange box In case of special application conditions, please consult for advice. Subject to alteration. Christian Bürkert GmbH & Co. KG 1209/7_EU-en_ p. 4/4
Positive displacement flowmeter
Positive displacement flowmeter Configurable outputs: one or two transistor output(s) and single or dual 4...20 ma current output(s) Removable backlit display of flow rate and/or 2 two totalized volumes
More informationType 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal
Positive displacement flow fitting for continuous and batch control High accuracy ± 0.5% 1/2 TO 4 (DN 15 to 100) INLINE Quarter Turn technology For highly viscous fluids Electronics for indication, monitoring,
More informationINSERTION flow sensor for continuous flow measurement
INSERTION flow sensor for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN)
More informationPositive displacement batch controller
8075 Batch controller Positive displacement batch controller Type 8075 can be combined with... Compact version for DN15 to DN100 Dosing On site calibration by Teach-In Check of input/output signals Total
More informationPaddle-wheel flow controller with optical principle for On/Off control
Paddle-wheel flow controller with optical principle for On/Off control Type 8039 can be combined with... Indication, monitoring, transmitting and On/Off control in one device. Programmable s (transistor
More informationPaddle-wheel flow controller for On/Off control
Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:
More informationINSERTION flowmeter with paddle wheel, ELEMENT design
INSERTION flowmeter with paddle wheel, design Up to PN, size of measurement pipes: DN to DN400 Configurable outputs: one or two transistor output(s) and single or dual 4... ma analog output(s) Removable
More informationINLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1
INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn
More informationPaddle-wheel flow controller for On/Off control
Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:
More informationInductive conductivity meter
Inductive conductivity meter Type 8228 can be combined with... Configurable outputs: up to 2 transistor and up to 2 analog 4... 20 ma outputs Removable backlighted display Simulation of process values
More informationInsertion magnetic inductive flowmeter
Insertion magnetic inductive flowmeter Sensor without moving parts Flowmeter with On/Off control Application related calibration by Teach-In function Clean in place (CIP) FDA-compliant materials Type 8041
More informationInductive conductivity meter
Inductive conductivity meter CIP version Type 8228 can be combined with... Standard version Perfect for concentrated liquids and wide conductivity range Pre-parameterized versions available for direct
More informationConductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands
Conductivity meter Configurable outputs: two transistor and single or dual analog 4... 20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants
More informationINLINE sensor-fitting with paddle wheel for flow measurement
INLINE sensorfitting with paddle wheel for flow measurement Type S030 can be combined for... 06 to 65 Closed pipe system, i.e. sensor included in fitting Quarterturn technology Transmitter available also
More informationINLINE fitting with paddle-wheel for flow measurement
INLINE fitting with paddlewheel for flow measurement 06 to 65 Closed pipe system, i.e. sensor inside fitting Quarterturn technology Type can be combined with... Electronics available for Indication, Monitoring,
More informationInline Paddle Wheel Flow Switch
Inline addle Wheel Flow Switch Economic integration in pipe systems without any additional piping Magnetic measuring principle Mechanical adjustment of setpoint Type can be combined with... Valve Alarm
More informationFPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters
FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) SERIES LOW Flow Positive Displacement Flowmeters To the owner: Please take a few minutes to read through the manual
More informationOM SERIES OVAL GEAR METERS. OM SERIES Oval Gear Meters
Oval Gear Meters OVAL GEAR METERS OM Series Oval Gear Meters are designed for low flow and high accuracy. OM Series Meters are great for viscous fluids. Units are available with from either a Reed Switch
More informationmacnaught flow measurement
macnaught flow measurement industrial flow meters macnaught.com.au flow meters m-series industrial macnaught flow measurement The M & MH range from Macnaught are positive displacement oval gear flowmeters
More informationINLINE fitting with paddle-wheel for flow measurement
ININE fitting with paddlewheel for flow measurement Type can be combined with... N 06 to N 65 Closed pipe system, i.e. sensor inside fitting Quarterturn technology Electronics available for Indication,
More informationOVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾
INST-019P_R4 11/2012 OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾ INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
More informationOVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 )
INST-075M_R4 11/2012 OVAL GEAR FLOWMETER MECHANICAL MODEL 075 (3 ) INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
More informationDigital ph transmitter
Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings
More informationOM004, OM006 & OM008 Oval Gear Meter
OM SERIES OM004, OM006 & OM008 Oval Gear Meter OM004 (1/8"), OM006 (1/4") and OM008 (3/8") Oval Gear Meters ACCURACY: ±1.0% OF READING Select Your Body Material: Aluminum or Stainless Steel The OM Small
More informationDigital ph transmitter
Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings
More informationMX06 - MX100 OVAL GEAR FLOWMETER SERIES APPROVED FOR USE IN HAZARDOUS AREAS
MXEX-INST Rev 9.0 04/2016 MX06 - MX100 OVAL GEAR FLOWMETER SERIES APPROVED FOR USE IN HAZARDOUS AREAS INSTRUCTION MANUAL To the Owner Page 1 of 33 index Installation Pre-installation checks. Page 3 Operating
More informationOVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )
INST-012M_R4 11/2012 OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ ) INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
More informationMX06 - MX100 OVAL GEAR FLOWMETER SERIES
MXL-INST Rev 7 04/2016 MX06 - MX100 OVAL GEAR FLOWMETER SERIES INSTRUCTION MANUAL To the Owner Please read and retain this instruction manual to assist you in the operation and maintenance of this product.
More informationFPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters
FPD1000-HP SERIES HIGH PRESSURE Positive Displacement Flowmeters To the owner: Thank you for purchasing an OMEGA FPD Series Flowmeter. Please take a few minutes to read through the manual before installing
More informationmacnaught flow measurement
macnaught flow measurement fuel and oil meters macnaught.com.au flow meters fuel and oil macnaught flow measurement The F range of oval gear fuel and oil meters from Macnaught are positive displacement
More informationOVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )
INST-006/009P_R9 06/2015 OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ ) INSTRUCTION MANUAL F Serial Meters To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this
More informationMX-SERIES OVAL GEAR FLOW METERS
Data Sheet MX-SERIES OVAL GEAR FLOW METERS Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com MX-Series Oval Gear Flow Meters Features and Advantages P From ¼ DN8 at 0.5LPH to 4 DN100
More informationOMP POSITIVE DISPLACEMENT FLOWMETERS
OMP POSITIVE DISPLACEMENT FLOWMETERS Flow Pressure Level Temperature measurement monitoring control Flow Ranges from 0.53 to 26 GPH to 4 to 92 GPM Handles Viscosities to 1,000,000 cps Pressure Ratings
More informationOperating Instructions for Oval Wheel Flowmeter. Model: DOC
Operating Instructions for Oval Wheel Flowmeter Model: DOC We don t accept warranty and liability claims neither upon this publication nor in case of improper treatment of the described products. The document
More information3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics
654 3/-way and x 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Fast response times Space saving ( x 3/-way version) Type 654 can be combined with...
More informationType SE35. Quickstart. English. Flowmeter Flow Transmitter
Flowmeter Flow Transmitter Quickstart 1. ABOUT THE QUICKSTART...3 2. INTENDED USE...4 3. BASIC SAFETY INFORMATION...4 4. GENERAL INFORMATION...6 5. DESCRIPTION OF THE NAME PLATE...6 6. TECHNICAL DATA...7
More informationPOSITIVE DISPLACEMENT FLOW METERS
POSITIVE DISPLACEMENT FLOW METERS ABOUT MACNAUGHT Macnaught Pty Ltd is a privately owned manufacturing company based in Australia, established in 1948. Macnaught s experience in Positive Displacement Flow
More informationFPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters
FPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters To the owner: Please take a few minutes to read through the manual before installing
More informationdisplay on the wall or in a panel away from the inline sensor SE30 for easy meter reading.
Analogue Flow Rate Indicator, DN 15...; PN 1...16 Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a large
More informationPOSITIVE DISPLACEMENT FLOW METERS
POSITIVE DISPLACEMENT FLOW METERS ABOUT MACNAUGHT Macnaught Pty Ltd is a privately owned manufacturing company based in Australia, established in 1948. Macnaught s experience in Positive Displacement Flow
More informationAxial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25
Installation Instruction Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25 Table of contents Page 1 Function of Turbotron 1 2 Safety instructions 2 3 Important notes and requirements
More informationOMP Positive Displacement Flowmeters
Flow Ranges From 0.53 to 26 GPH Through 4 to 132 GPH Handles Viscosities to 1,000,000 cps Handles Viscosities to 1,000,000 cps Low Head Loss Oval Gear Design OMP Series Medium & High Flow Meters OMP-1
More informationElectrical position feedback for actuator sizes Ø mm
Electrical position feedback for actuator sizes Ø 40-125 mm Type 1062 can be combined with Simple installation, convertible or retrofittable Self-adjusting trip cam for closed position LEDs provide local
More informationINSERTION Adaptor for analysis
INSERTION Adaptor for analysis Type can be combined with... Universal adaptor for type 8202 and 8222 ELEMENT s in pure, aggressive or contaminated liquids Adaptation into standard piping systems or conversion
More informationRUN ACCUM. TOTAL STOP BAT LOW HIGH
TURBOPULSE TURBINE FLOWMETER INSTRUCTION MANUAL gal RUN ACCUM. TOTAL STOP BAT LOW HIGH RESET > PROGRAM ENTER ACCUM TOTAL ^ RATE TOTAL TP050 TABLE OF CONTENTS 1. INTRODUCTION Overview 1 1.1 Model number
More informationType Operating Instructions. Bedienungsanleitung Manuel utilisateur
Water flow rate transmitter Wasser-Durchfluss-Transmitter Transmetteur de débit d eau Operating Instructions Bedienungsanleitung Manuel utilisateur We reserve the right to make technical changes without
More information2/2 or 3/2 way direct acting rocker solenoid valve
2/2 or 3/2 way direct acting rocker solenoid valve With isolating diaphragm Ultra low dead volume Type 6126 can be combined with... High back-pressure tightness Normally closed, normally open or universal
More informationOVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ )
012 Mech 07.11 OVAL GEAR FLOWMETER MECHANICAL MODEL 012 (½ ) INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
More informationmacnaught flow measurement
macnaught flow measurement solvent flow meters macnaught.com.au flow meters solvent macnaught flow measurement The "S" range of oval gear fuel and oil meters from Macnaught are positive displacement oval
More informationFLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE
FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor FlowX3 F3.20 is a paddlewheel flow sensor suitable for system at high pressure and at critical temperature. F3.20 is designed for use with every kind
More informationOVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1
025 Puls 07.11 OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1 INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist you
More informationPositive Displacement Flowmeters GM020 series instruction manual
ACCURATE FLOWMETERS & INSTRUMENTATION PVT. LTD. Positive Displacement Flowmeters GM020 series instruction manual GM020 Pulse Meter From serial No. CXXXX Accurate Flowmeters & Instrumentation Pvt. Ltd.
More information2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50
2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, 10-50 (2652) (2655) 2 or ball valve Pneumatic actuator Compact design Visual position indicator Types 2652/2655 can be
More informationDirect-acting 3/2 way plunger valve
Direct-acting 3/2 way plunger valve Direct-acting, compact valve with diameter of up to DN 2.5 Vibration-proof, bolted coil system Banjo threaded connection for direct mounting on pneumatic valves Type
More informationRCM - Direct Reading Flowmeters
Compact Design Easy to Install Horizontal or Vertical Installation Flow Rates up to 3000 GPM (Liquid) or 20000 SCFM (Gas) Low Pressure Drop Optional Alarms and Output Signals Accuracy: ± 3% of full scale
More informationSimple float switch TCL001/8181
Simple float switch Switch for neutral and aggressive liquids NO/NC, alternating Reed contact Vertical or horizontal mounting Molded lying leads (Type 8181) or cable (Type TCL001) Float switch with hermetically
More informationOVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ )
012 Puls 07.11 OVAL GEAR FLOWMETER ELECTRONIC MODEL 006/009 (¼ ) INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist
More informationG2 Industrial Grade Meters
G2 Industrial Grade Meters The unique modular approach of the Industrial Grade Meter line allows you to section 2: g2 industrial grade meters design a meter to match your specific application. Turbine
More informationPositive Displacement Flowmeters GM020 series instruction manual
MS244G 0603 0003 Positive Displacement Flowmeters GM020 series instruction manual GM020 Pulse Meter From serial No. CXXXX To the owner Thank you for purchasing a GPI GM Series Flow Meter. Please take a
More informationIndustrial OG meter series IOG Inline and flanged oval gear meter
Badger Meter Europa GmbH Nürtinger Str. 76 72639 Neuffen (Germany) Tel. +49-7025-9208-0 Fax +49-7025-9208-15 www.badgermeter.de badger@badgermeter.de Industrial OG meter series IOG Inline and flanged oval
More information2/2 way Angle-Seat Valve for medium up to C, DN15-50
Type 2000 can be combined with 2/2 way Angle-Seat Valve for medium up to + 180 C, DN15-50 High flow rates Very high cycle life Clamp body according to EN ISO 2852, BS 4825 or ASME BPE For process valves
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation
Flowmeter with paddle-wheel Durchfluss-Messgerät mit Flügelrad Débitmètre à ailette Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the right to make technical changes without
More information2/2-way Angle Seat Valve, manually operated, for media up to +180 C
2/2-way Angle Seat Valve, manually operated, for media up to +180 C Position indication Adjustable flow rates Stainless steel 316L valve body Compact industrial design with long service life /2702 can
More informationPneumatic control unit for decentralized automation of ELEMENT process valves
890 Pneumatic control unit for decentralized automation of ELEMENT process valves Type 890 can be combined with... Compact design Integrated pilot valve with manual override Integrated control air routing
More informationFlowmeter for Gases. Type Type can be combined with... Type 8802-YG Process control valve. Type 5281 Solenoid valve
Flowmeter for Gases Thermal mass flow measurement Pipe sizes up to 2" Integrated inlet and outlet pipes for flow conditioning -20mA signal output of process value Type can be combined with... Type 8802-YG
More informationDPT TARGET TYPE FLOWMETERS
DPT TARGET TYPE FLOWMETERS Flow Pressure Level Temperature measurement monitoring control S3 Patented Target/Leaf-Spring Design Minimal Wear Components 1.5-8 to 225-500 GPM Water Line Sizes 3/8 to 3" Wide
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation
Flowmeter with paddle-wheel Durchfluss-Messgerät mit Flügelrad Débitmètre à ailette Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the right to make technical changes without
More information2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50
/- and 3/-way Ball Valve with pneumatic rotary actuator, plastic body, DN -50 Radially expandable body Pneumatic actuator in compact model Optical position indicator Control valve acc. to NAMUR Type 5
More informationPositive Displacement Flowmeters GM007 series instruction manual
MS499G 0603 0003 Positive Displacement Flowmeters GM007 series instruction manual GM007 Pulse Meter From serial No. CXXXX To the owner Thank you for purchasing a GPI GM GPI by telephone or fax.] Series
More information2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50
2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50 Suitable for aggressive media High flow rate value Actuator with adjustable limit switches Visual position indicator Safe
More informationType Pressure Transmitter with display. Pressure Transmitter. Technical data. DN15-50 Body material. Stainless steel 316L Actuator material
2/2-way Angle Seat Valve, manually operated, for media up to +180 C Position indication Adjustable flow rates Stainless steel 316L valve body Compact industrial design with long service life Excellent
More informationTypes 8025 / Operating Instructions. Bedienungsanleitung Manuel d utilisation. Flowmeter Durchflussmessgerät Débitmètre
Types 805 / 8035 Flowmeter Durchflussmessgerät Débitmètre Operating Instructions Bedienungsanleitung Manuel d utilisation We reserve the right to make technical changes without notice. Technische Änderungen
More informationMODEL MX75 3 OVAL GEAR FLOWMETER
Installation & Maintenance Instructions MODEL MX75 3 OVAL GEAR FLOWMETER Supplied by.com Call us on +44 (0)118 916 9420 Email info@247able.com MXL-INST75 Rev 1 06/2013 MODEL MX75 3 OVAL GEAR FLOWMETER
More informationOVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1. Type CR for Corrosive Applications
INST-CR025P_R1 012/2011 OVAL GEAR FLOWMETER ELECTRONIC MODEL 025 / 1 Type CR for Corrosive Applications INSTRUCTION MANUAL To the Owner PLEASE READ THIS SAFTEY INFORMATION CAREFULLY BEFORE USE. Read and
More information2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65
2/2-way ball valve with electric rotary actuator, ball valve in, N 10-65 Suitable for aggressive media High flow rate value -piece Actuator with adjustable limit switches 2-piece Visual position indicator
More informationType S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation
Type S030 INLINE fitting We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques. Operating Instructions Bedienungsanleitung
More informationFlow Controller, flow control system for gases
Flow Controller, flow control system for gases Highly cost effective solution, thanks to the integrated system Reliable, robust system Automatic process tune Simple to operate Type 8750 can be combined
More information3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base
3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base Sub-base Direct-acting, normally closed and normally open Brass and stainless steel body Electrical cable plug Form A With or without manual override
More informationFLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES
FLS F6.60 MAGMETER FLOW SENSOR The new F6.60 and F6.63 are flow meters without moving mechanical parts which can be applied for the measurement of dirty liquids so long as they are conductive and homogeneous.
More information2/2-way Angle-Seat Control Valve with stainless steel design for media up to +185ºC, DN15-65
2/2-way Angle-Seat Control Valve with stainless steel design for media up to +185ºC, DN15-65 Excellent combination of good control characteristic and high fl ow rates High cycle life Clean design for optimal
More information2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65
2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, 10-65 Suitable for aggressive media High flow rate value -piece Actuator with adjustable limit switches 2-piece Visual position
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationOVAL GEAR. Large Capacity Positive Displacement Mechanical Flowmeters. Models: 3 (D-750), 3 (D-1000), 4 (D-1500) & 4" (D-2500)
OVAL GEAR Large Capacity Positive Displacement Mechanical Flowmeters INSTRUCTION MANUAL Models: 3 (D-750), 3 (D-1000), 4 (D-1500) & 4" (D-2500) Index / contents 1 1.0 General Page 1.1 Overview 2 1.2 Operating
More informationIM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL
IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL To the Owner PLEASE READ THIS INFORMATION CAREFULLY BEFORE USE. Read and retain this instruction manual to assist you in the operation
More information2/2-way Globe Control Valve with stainless steel design for media up to +185ºC, DN
2/2-way Globe Control Valve with stainless steel design for media up to +185ºC, DN 10-100 Type 2301 flange can be combined with Excellent control characteristics High cycle life Flow optimised body in
More informationMagnetic Paddle Flow Sensor/Switch for Easy On/Off Control
Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control INLINE Quarter-Turn ON/OFF Control System for Monitoring and Switching Mechanical adjustment of set point No contact to Fluid thanks to INLINE
More information2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65
2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65 Type 2000 can be combined with High flow rate Long life cycle NC and NO universal s with modular universal accessory
More informationDTK. OEM Pelton Wheel Flow Sensor
OEM Pelton Wheel Flow Sensor measuring monitoring analyzing DTK Measuring Range: 0.8...9.5 to 6...90 GPH Water Measures Clear or Opaque Liquids Stainless Steel Body Pelton Wheel Design Requires No Inlet
More informationI N S T R U C T I O N M A N U A L
I N S T R U C T I O N M A N U A L Oval Gear Positive Displacement Mechanical Flowmeters Models: 3 (080), 3 (080E), 4 (100), 4 (100E) NSW TEL: (02) 9939 0711 FAX: (02) 9939 0411 QLD/PNG TEL: (07) 3204 9166
More information3/2-way Solenoid Valve, direct-acting, NC or NO
3/2-way Solenoid Valve, direct-acting, NC or NO Electrical connection cable plug, Form A With or without manual override as standard Threaded port and sub-base s Impulse optional Type 6014 can be combined
More informationMODEL MX12 1/2 OVAL GEAR FLOWMETER
MXL-INST12 Rev 4 12/2013 MODEL MX12 1/2 OVAL GEAR FLOWMETER INSTRUCTION MANUAL To the Owner Please read and retain this instruction manual to assist you in the operation and maintenance of this product.
More informationType 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions
More information9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER
Design Specifications DS-9900 Revision 04 9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER 2-Wire loop powered flowmeter/transmitter 316 Stainless steel measuring unit Automatic temperature
More informationPositive Displacement Flowmeters GM515 series instruction manual
MS103G 0603 0004 Positive Displacement Flowmeters GM515 series instruction manual GM515 Mechanical meter From serial No. CXXXX To the owner Please take a few minutes to read thorugh this manual before
More information2/2-way Globe Control Valve, threaded port connection, DN 10-65
2/2-way Globe Control Valve, threaded port connection, DN 10-65 Type 2712 can be combined with... Classic design with interchangeable trims, 3 to 5 Kvs-value per connection port Excellent control characteristic
More informationFlow Sensors & Instruments
STAINESS STEE TURBINE FOWMETERS Serie X IG PRESSURE AND IG TEMPERATURE Principle of Operation The x range of Turbine Flowmeters meet the demand of most liquid measurement applications. They basically consist
More informationSIGNET 7002 Vortex Flow Sensor ENGLISH
SIGNET 7002 Vortex Flow Sensor ENGLISH 3-7002.090 C-7/02 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Never install sensor without O-Rings. 3. Confirm chemical compatibility
More informationPOSITIVE DISPLACEMENT FLOWMETERS
MS589 0409 00 POSITIVE DISPLACEMENT FLOWMETERS M80 SERIES INSTRUCTION MANUAL M80 Pulse; Standard LCD; Deluxe LCD; From serial No.CXXXX TO THE OWNER Please take a few minutes to read through this manual
More informationThe experts in fluid technology
MS85 1005 0007 The experts in fluid technology Positive Displacement Flowmeters M10 series instruction manual M10 Mechanical meter From serial No. CXXXX To the owner Please take a few minutes to read thorugh
More informationTurbotron // VTH15, VTM15, VTP15, VTI15
1 Flow Measuring Turbine flow sensors Turbotron // VTH15, VTM15, VTP15, VTI15 VTH15 BEST SELLER VTM15 Your advantages Series VTH15 VTM15 Cost optimized version For medium temperature up to 120 C Type VTH15